SUBMITTAL DATA SHEET SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC HEAT UNITS, 3 THROUGH 12-1/2 TONS MODELS: ZU/ZW/ZKTA3 to T12, ZST06 to T12, ZVTA3 to TA5 JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF: APPROVAL: SUBMITTED BY: DATE: UNIT DESIGNATION: SCHEDULE NO. CONSTRUCTION: MODEL NO. COOLING PERFORMANCE TOTAL CAPACITY- - - - - - - - - - - - - - _____ MBH SENSIBLE CAPACITY - - - - - - - - - - - _____ MBH OUTDOOR DESIGN TMP. _________ °F DB/WB TOTAL SUPPLY AIR - - - - - - - - - - - - _____ CFM TEMP. OF AIR ENTERING EVAPORATOR COIL - - - - - - - - - - - - - - _____ °F POWER INPUT REQ. - - - - - - - - - - - - - _____ KW (LESS BLOWER MOTOR) HEATING PERFORMANCE ELECTRIC HEAT - - - - - - - - - - - - - - - - _____ KW GAS-FIRED INPUT CAP. - - - - - - - - - _____ MBH SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR - - - - - - - - - - - - _____ CFM EXT. STATIC PRESS. - - - - - - - - - - - _____ IWG BLOWER SPEED- - - - - - - - - - - - - - - - ____ RPM POWER OUTPUT REQ. - - - - - - - - - - _____ BHP MOTOR RATING - - - - - - - - - - - - - - - - _____ HP POWER INPUT REQ. - - - - - - - - - - - - - _____ KW ELECTRICAL DATA POWER SUPPLY - - - - - - - - - - - - - - - __________ TOTAL UNIT AMPACITY - - - - - - - - _____ AMPS MAX. OVERCURRENT DEVICE __ FUSE __ BREAKER - - - - - - - - - _____ AMPS TOTAL UNIT WEIGHT INCLUDING FACTORY- INSTALLED OPTIONS- - - - - - - - - - - - - - - - - - - - - _____ LBS Johnson Controls Unitary Products 5123283-TSD-A-0515 5123283-TSD-A-0515 3 thru 4 Ton ZU/ZW, 3 Ton ZK (See Physical Dimensions table for exact models) 29.75 15.51 29.52 59.00 Ø 25.31 B See detail A for gas inlet A C D E 11 3/8 F See detail B for drain location LEFT 4 3/16 FRONT 59 21 3/16 27 5/16 89 2 Johnson Controls Unitary Products 5123283-TSD-A-0515 3, 4, 5 Ton ZV, 5 Ton ZU/ZW, 4 and 5 Ton ZK and 6 thru 10 Ton ZS/ZU/ZW/ZK (See Physical Dimensions table for exact models) 29.69 15.25 15.38 59.00 15.38 2X Ø 24.38 B SEE DETAIL A FOR GAS INLET A C D E 11.38 F 59.00 4.19 LEFT 27.31 SEE DETAIL B FOR DRAIN LOCATION 21.19 89.00 FRONT Johnson Controls Unitary Products 3 5123283-TSD-A-0515 12.5 Ton ZU/ZW/ZKT12 28.86 29.66 44.09 15.23 14.85 29.03 29.03 14.85 Ø 24.58 TYP. 4 PL. 15.23 B See detail A for gas inlet A C D E 11 3/8 F See detail B for drain location LEFT 59 4 3/16 21 3/16 FRONT 27 5/16 89 4 Johnson Controls Unitary Products 5123283-TSD-A-0515 12.5 Ton ZST12 45.64 14.92 4X Ø 24.38 14.92 58.09 14.92 29.95 30.11 B SEE DETAIL A FOR GAS INLET A C D E 11.38 F 59.00 LEFT 4.19 SEE DETAIL B FOR DRAIN LOCATION 27.31 21.19 89.00 FRONT Johnson Controls Unitary Products 5 5123283-TSD-A-0515 3 to 12.5 Ton Unit Physical Dimensions Unit Model Number A 42 50 3/4 50 3/4 42 50 3/4 50 3/4 42 50 3/4 50 3/4 42 42 50 3/4 50 3/4 42 ZS T06, T07 ZST08, T10 ZST12 ZUTA3, TA4, TA5, T06, T07 ZUT08, T10 ZUT12 ZWTA3, TA4, TA5 ZWT06, T07, T08, T10 ZWT12 ZKTA3, TA4, TA5 ZKT06, T07 ZKT08, T10 ZKT12 ZVTA3, TA4, TA5 B 89 89 119 1/2 89 89 119 1/2 89 89 119 1/2 89 89 89 119 1/2 89 Dimension (in.) C 22 1/8 18 30 3/16 24 30 3/16 24 22 1/8 18 30 3/16 24 30 3/16 24 22 1/8 18 30 3/16 24 30 3/16 24 22 1/8 18 22 1/8 18 30 3/16 24 30 3/16 24 22 1/8 18 D 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 15 17 17 15 17 17 15 17 17 15 15 17 17 15 E 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 6 6 6 6 6 6 6 6 6 6 6 6 6 6 F 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 3/16 Detail A 3.184 3.184 Gas Pipe Inlet Gas Pipe Inlet Ø 2.000 Ø 2.000 Gas Exhaust Vent Gas Exhaust Vent Ø 3.126 Ø 3.126 17.541 14.594 7.715 7.705 4.737 4.727 42” CABINET 50 3/4” CABINET Detail B 5-3/8 3/4” FPT 6 Johnson Controls Unitary Products 5123283-TSD-A-0515 3 to 12.5 Ton Unit Side Duct Openings Dot Plugs 18-1/4 A Return Air Supply Air D B 2-31/32 5-5/32 C 31-11/16 12.5 Ton Unit Side Duct Openings - ZU/ZW/ZKT12 Dot Plugs 18-1/4 A D B 5-5/32 2-7/8 C 31-5/8 12.5 Ton Unit Side Duct Openings - ZST12 Dot Plugs 18-1/4 A D B 5-5/32 2-7/8 C Johnson Controls Unitary Products 31-5/8 7 5123283-TSD-A-0515 3 to 12.5 Ton Side Duct Dimensions Unit Model Number ZS T06, T07 ZST08, T10 ZST12 ZUTA3, TA4, TA5, T06, T07 ZUT08, T10 ZUT12 ZWTA3, TA4, TA5 ZWT06, T07, T08, T10 ZWT12 ZKTA3, TA4, TA5 ZKT06, T07 ZKT08, T10 ZKT12 ZVTA3, TA4, TA5 Dimension (in.) A 27 3/4 28 1/4 28 1/4 27 3/4 28 1/4 28 1/4 27 3/4 28 1/4 28 1/4 27 3/4 27 3/4 28 1/4 28 1/4 27 3/4 B 12 18 18 12 18 18 12 18 18 12 12 18 18 12 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 1/16 C D 27 1/2 28 1/4 28 1/4 27 1/2 28 1/4 28 1/4 27 1/2 28 1/4 28 1/4 27 1/2 27 1/2 28 1/4 28 1/4 27 1/2 16 18 1/4 18 1/4 16 18 1/4 18 1/4 16 18 1/4 18 1/4 16 16 18 1/4 18 1/4 16 3 to 12.5 Ton Unit Clearances Direction Top1 Front Rear Distance (in.) 72 36 36 Direction Right Left Bottom2 Distance (in.) 12 36 0 1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet. 2. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. 8 Johnson Controls Unitary Products 5123283-TSD-A-0515 3 to 12.5 Ton Unit Bottom Duct Openings (inches) 89 32 11/16 6 13/16 6 13/16 SUPPLY AIR RETURN AIR 27 1/2 LEFT 18 24 RIGHT 21 20 1/8 19 1/8 17 1/8 12 5/16 Bottom condensate drain 14 1/2 25 9/16 Bottom gas supply entry 16 3/8 18 1/16 FRONT TOP VIEW Bottom power, control and convenience outlet wiring entry 3X Ø 0.875 Ø 2.469 Johnson Controls Unitary Products 9 5123283-TSD-A-0515 3 to 12.5 Ton Unit Electrical Entry (inches) Disconnect Swith Cover Power Entry Ø 2-1/2 Control Entry Ø 7/8 Power Entry Ø 2-1/2 Convenience Outlet Cover Convenience Outlet Power Entry Ø 7/8 FRONT 3 to 12.5 Ton Unit Left Economizer Duct Opening (inches) 30-3/8 4-5/16 10 Johnson Controls Unitary Products 5123283-TSD-A-0515 3 to 12.5 Ton Unit Roof Curb (inches) RIGHT 80-5/8 INSULATED DECK UNDER CONDENSER SECTION 20 SUPPLY 20 6 RETURN 2 TYP. 30 INSULATED DECK UNDER COMPRESSOR SECTION 50-1/2 FRONT 8 or 14 3 to 12.5 Ton Unit Transition Roof Curb (inches) 2 TYP 50-1/2 30-1/2 23 4 80-5/8 26 RETURN SUPPLY 10 76-5/8 94 FRONT Johnson Controls Unitary Products 59-1/4 64-1/4 RIGHT 11 5123283-TSD-A-0515 Economizer Downflow W/Power Exhaust Fresh Air Hood Low Leak Economizer Power Exhaust Barometric Relief Damper Barometric Relief Hood Economizer End Return W/Power Exhaust Fresh Air Hood Field Installed Duct Work Low Leak Economizer Power Exhaust Barometric Relief Damper Barometric Relief Hood 12 Johnson Controls Unitary Products 5123283-TSD-A-0515 Field Installed Horizontal Economizer W/Power Exhaust Return Air Damper Field Installed Duct Work Fresh Air Damper Power Exhaust Barometric Relief Damper Barometric Relief Hood Fresh Air Hood Roof Curb Cutaway 3/4” X 1-1/4” WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES 2“ UNIT BASE 3.75” WOOD NAILER 3.56” UNIT BASE RAILS 14” 8“ MIN. ABOVE FINISHED ROOF CURB FRAME COUNTERFLASHING CAN’T STRIP INSULATION AND ROOFING MATERIAL INSULATION ROOF DECK AND SUPPORT STRUCTURE Johnson Controls Unitary Products 13 FACTORY INSTALLED OPTIONS ELECTRIC HEATER MODEL - KW_____VOLTS_____ STAINLESS STEEL HEAT EXCHANGER - - - - - - - - - - ALUMINIZED STEEL HEAT EXCHANGER - - - - - - - - - STAINLESS STEEL DRAIN PAN- - - - - - - - - - - - - - - - - ECONOMIZER, DOWNFLOW, END RETURN HORIZONTAL- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - POWER EXHAUST - - - - - - - - - - - - - - - - - - - - - - - - - - MOTORIZED AIR DAMPER - - - - - - - - - - - - - - - - - - - - HIGH STATIC INDOOR BLOWER MOTOR - - - - - - - - - DISCONNECT SWITCH - - - - - - - - - - - - - - - - - - - - - - - CONVENIENCE OUTLET, POWERED - - - - - - - - - - - - CONVENIENCE OUTLET, NON-POWERED - - - - - - - - SMOKE DETECTOR (RETURN) - - - - - - - - - - - - - - - - - SMOKE DETECTOR (SUPPLY) - - - - - - - - - - - - - - - - - PHASE MONITOR1 - - - - - - - - - - - - - - - - - - - - - - - - - - COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - FILTERS, 2" PLEATED, MERV 7 - - - - - - - - - - - - - - - - FILTERS, 4" PLEATED, MERV 13 - - - - - - - - - - - - - - - PHENOLIC COATED EVAPORATOR COILS - - - - - - - - PHENOLIC COATED CONDENSER COILS - - - - - - - - - E-COAT EVAPORATOR COILS - - - - - - - - - - - - - - - - - E-COAT CONDENSER COILS - - - - - - - - - - - - - - - - - - INTELLISPEED WITH VFD - - - - - - - - - - - - - - - - - - - - INTELLISPEED, VFD AND MANUAL BYPASS - - - - - - INTELLISPEED, VFD READY (FOR CUSTOMER-PROVIDED, FIELD-INSTALLED DRIVE) - - - - - - - - - - - - - - VAV W/VFD- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - VAV W/VFD AND MANUAL BYPASS - - - - - - - - - - - - - VAV, VFD READY (FOR CUSTOMER-PROVIDED, FIELDINSTALLED DRIVE) - - - - - - - - - - - - - - - - - - - - - - - - - - BAS OPTION Simplicity® Smart Equipment (SSE) w/Communication BACnet MS/TP (programmable to Modbus or N2 protocols) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Honeywell™ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Novar® - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CPC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FIELD INSTALLED ACCESSORIES ROOF CURB, 8" - - - - - - - - - - - - - - - - - - - - - - - - - - - - ROOF CURB, 14"- - - - - - - - - - - - - - - - - - - - - - - - - - - - TRANSITION ROOF CURB - - - - - - - - - - - - - - - - - - - - COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HAIL GUARD- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PERMANENT FILTERS - - - - - - - - - - - - - - - - - - - - - - - METAL FILTER FRAME KIT - - - - - - - - - - - - - - - - - - - - DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - AIR PROVING SWITCH - - - - - - - - - - - - - - - - - - - - - - - BURGLAR BARS (DOWNFLOW ONLY) - - - - - - - - - - - LOW AMBIENT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - SMOKE DETECTOR (RETURN) - - - - - - - - - - - - - - - - - SMOKE DETECTOR (SUPPLY) - - - - - - - - - - - - - - - - - CO2 SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PHASE MONITOR1 - - - - - - - - - - - - - - - - - - - - - - - - - - ECONOMIZER, DOWNFLOW, END RETURN HORIZONTAL- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ECONOMIZER, HORIZONTAL - - - - - - - - - - - - - - - - - - SINGLE ENTHALPY- - - - - - - - - - - - - - - - - - - - - - - - - - DUAL ENTHALPY - - - - - - - - - - - - - - - - - - - - - - - - - - - POWER EXHAUST - - - - - - - - - - - - - - - - - - - - - - - - - - MOTORIZED OUTDOOR AIR DAMPER - - - - - - - - - - - MANUAL OUTDOOR AIR DAMPER - - - - - - - - - - - - - - ELECTRIC HEATER MODEL - KW_____VOLTS_____ FLUE EXTENSION KIT- - - - - - - - - - - - - - - - - - - - - - - - GAS PIPING KIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - GAS HEAT PROPANE ADAPTER KIT - - - - - - - - - - - - - GAS HEAT HIGH ALTITUDE KIT, NATURAL GAS - - - - GAS HEAT HIGH ALTITUDE KIT, PROPANE- - - - - - - - -60°F GAS HEAT KIT - - - - - - - - - - - - - - - - - - - - - - - - - WALL MOUNT TEMPERATURE SENSOR- - - - - - - - - - WALL MOUNT TEMPERATURE SENSOR WITH OVERRIDE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WALL MOUNT TEMPERATURE SENSOR WITH OVERRIDE & SET POINT ADJ. - - - - - - - - - - - - - - - - - - HUMIDITY SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - 1. Phase monitor standard on units with scroll compressors. Subject to change without notice. Printed in U.S.A. Copyright © 2015 by Johnson Controls, Inc. All rights reserved. York International Corporation 5005 York Drive Norman, OK 73069 5123283-TSD-A-0515 Supersedes: Nothing