SUBMITTAL DATA SHEET
SINGLE PACKAGE AIR CONDITIONERS AND GAS/ELECTRIC
HEAT UNITS, 3 THROUGH 12-1/2 TONS
MODELS: ZU/ZW/ZKTA3 to T12, ZST06 to T12, ZVTA3 to TA5
JOB NAME:
LOCATION:
PURCHASER:
ORDER NO:
ENGINEER:
SUBMITTED TO:
FOR:
REF:
APPROVAL:
SUBMITTED BY:
DATE:
UNIT DESIGNATION:
SCHEDULE NO.
CONSTRUCTION:
MODEL NO.
COOLING PERFORMANCE
TOTAL CAPACITY- - - - - - - - - - - - - - _____ MBH
SENSIBLE CAPACITY - - - - - - - - - - - _____ MBH
OUTDOOR DESIGN TMP. _________ °F DB/WB
TOTAL SUPPLY AIR - - - - - - - - - - - - _____ CFM
TEMP. OF AIR ENTERING
EVAPORATOR COIL - - - - - - - - - - - - - - _____ °F
POWER INPUT REQ. - - - - - - - - - - - - - _____ KW
(LESS BLOWER MOTOR)
HEATING PERFORMANCE
ELECTRIC HEAT - - - - - - - - - - - - - - - - _____ KW
GAS-FIRED INPUT CAP. - - - - - - - - - _____ MBH
SUPPLY AIR BLOWER PERFORMANCE
TOTAL SUPPLY AIR - - - - - - - - - - - - _____ CFM
EXT. STATIC PRESS. - - - - - - - - - - - _____ IWG
BLOWER SPEED- - - - - - - - - - - - - - - - ____ RPM
POWER OUTPUT REQ. - - - - - - - - - - _____ BHP
MOTOR RATING - - - - - - - - - - - - - - - - _____ HP
POWER INPUT REQ. - - - - - - - - - - - - - _____ KW
ELECTRICAL DATA
POWER SUPPLY - - - - - - - - - - - - - - - __________
TOTAL UNIT AMPACITY - - - - - - - - _____ AMPS
MAX. OVERCURRENT DEVICE
__ FUSE __ BREAKER - - - - - - - - - _____ AMPS
TOTAL UNIT WEIGHT
INCLUDING FACTORY- INSTALLED
OPTIONS- - - - - - - - - - - - - - - - - - - - - _____ LBS
Johnson Controls Unitary Products
5123283-TSD-A-0515
5123283-TSD-A-0515
3 thru 4 Ton ZU/ZW, 3 Ton ZK (See Physical Dimensions table for exact models)
29.75
15.51
29.52
59.00
Ø 25.31
B
See detail A for gas inlet
A
C
D
E
11 3/8
F
See detail B for drain location
LEFT
4 3/16
FRONT
59
21 3/16
27 5/16
89
2
Johnson Controls Unitary Products
5123283-TSD-A-0515
3, 4, 5 Ton ZV, 5 Ton ZU/ZW, 4 and 5 Ton ZK and 6 thru 10 Ton ZS/ZU/ZW/ZK (See Physical Dimensions table for exact
models)
29.69
15.25
15.38
59.00
15.38
2X Ø 24.38
B
SEE DETAIL A FOR GAS INLET
A
C
D
E
11.38
F
59.00
4.19
LEFT
27.31
SEE DETAIL B
FOR DRAIN LOCATION
21.19
89.00
FRONT
Johnson Controls Unitary Products
3
5123283-TSD-A-0515
12.5 Ton ZU/ZW/ZKT12
28.86
29.66
44.09
15.23
14.85
29.03
29.03
14.85
Ø 24.58 TYP. 4 PL.
15.23
B
See detail A for gas inlet
A
C
D
E
11 3/8
F
See detail B for drain location
LEFT
59
4 3/16
21 3/16
FRONT
27 5/16
89
4
Johnson Controls Unitary Products
5123283-TSD-A-0515
12.5 Ton ZST12
45.64
14.92
4X Ø 24.38
14.92
58.09
14.92
29.95
30.11
B
SEE DETAIL A FOR GAS INLET
A
C
D
E
11.38
F
59.00
LEFT
4.19
SEE DETAIL B
FOR DRAIN LOCATION
27.31
21.19
89.00
FRONT
Johnson Controls Unitary Products
5
5123283-TSD-A-0515
3 to 12.5 Ton Unit Physical Dimensions
Unit Model Number
A
42
50 3/4
50 3/4
42
50 3/4
50 3/4
42
50 3/4
50 3/4
42
42
50 3/4
50 3/4
42
ZS T06, T07
ZST08, T10
ZST12
ZUTA3, TA4, TA5, T06, T07
ZUT08, T10
ZUT12
ZWTA3, TA4, TA5
ZWT06, T07, T08, T10
ZWT12
ZKTA3, TA4, TA5
ZKT06, T07
ZKT08, T10
ZKT12
ZVTA3, TA4, TA5
B
89
89
119 1/2
89
89
119 1/2
89
89
119 1/2
89
89
89
119 1/2
89
Dimension (in.)
C
22 1/8
18
30 3/16
24
30 3/16
24
22 1/8
18
30 3/16
24
30 3/16
24
22 1/8
18
30 3/16
24
30 3/16
24
22 1/8
18
22 1/8
18
30 3/16
24
30 3/16
24
22 1/8
18
D
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
15
17
17
15
17
17
15
17
17
15
15
17
17
15
E
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
6
6
6
6
6
6
6
6
6
6
6
6
6
6
F
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
Detail A
3.184
3.184
Gas Pipe Inlet
Gas Pipe Inlet
Ø 2.000
Ø 2.000
Gas Exhaust Vent
Gas Exhaust Vent
Ø 3.126
Ø 3.126
17.541
14.594
7.715
7.705
4.737
4.727
42” CABINET
50 3/4” CABINET
Detail B
5-3/8
3/4” FPT
6
Johnson Controls Unitary Products
5123283-TSD-A-0515
3 to 12.5 Ton Unit Side Duct Openings
Dot Plugs
18-1/4
A
Return
Air
Supply Air
D
B
2-31/32
5-5/32
C
31-11/16
12.5 Ton Unit Side Duct Openings - ZU/ZW/ZKT12
Dot Plugs
18-1/4
A
D
B
5-5/32
2-7/8
C
31-5/8
12.5 Ton Unit Side Duct Openings - ZST12
Dot Plugs
18-1/4
A
D
B
5-5/32
2-7/8
C
Johnson Controls Unitary Products
31-5/8
7
5123283-TSD-A-0515
3 to 12.5 Ton Side Duct Dimensions
Unit Model Number
ZS T06, T07
ZST08, T10
ZST12
ZUTA3, TA4, TA5, T06, T07
ZUT08, T10
ZUT12
ZWTA3, TA4, TA5
ZWT06, T07, T08, T10
ZWT12
ZKTA3, TA4, TA5
ZKT06, T07
ZKT08, T10
ZKT12
ZVTA3, TA4, TA5
Dimension (in.)
A
27 3/4
28 1/4
28 1/4
27 3/4
28 1/4
28 1/4
27 3/4
28 1/4
28 1/4
27 3/4
27 3/4
28 1/4
28 1/4
27 3/4
B
12
18
18
12
18
18
12
18
18
12
12
18
18
12
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
1/16
C
D
27 1/2
28 1/4
28 1/4
27 1/2
28 1/4
28 1/4
27 1/2
28 1/4
28 1/4
27 1/2
27 1/2
28 1/4
28 1/4
27 1/2
16
18 1/4
18 1/4
16
18 1/4
18 1/4
16
18 1/4
18 1/4
16
16
18 1/4
18 1/4
16
3 to 12.5 Ton Unit Clearances
Direction
Top1
Front
Rear
Distance (in.)
72
36
36
Direction
Right
Left
Bottom2
Distance (in.)
12
36
0
1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet.
2. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials.
8
Johnson Controls Unitary Products
5123283-TSD-A-0515
3 to 12.5 Ton Unit Bottom Duct Openings (inches)
89
32 11/16
6 13/16
6 13/16
SUPPLY
AIR
RETURN
AIR
27 1/2
LEFT
18
24
RIGHT
21
20 1/8 19 1/8
17 1/8
12 5/16
Bottom condensate drain
14 1/2
25 9/16
Bottom gas
supply entry
16 3/8
18 1/16
FRONT
TOP VIEW
Bottom power, control
and convenience outlet
wiring entry
3X Ø 0.875
Ø 2.469
Johnson Controls Unitary Products
9
5123283-TSD-A-0515
3 to 12.5 Ton Unit Electrical Entry (inches)
Disconnect Swith Cover
Power Entry Ø 2-1/2
Control Entry Ø 7/8
Power Entry Ø 2-1/2
Convenience Outlet Cover
Convenience Outlet
Power Entry Ø 7/8
FRONT
3 to 12.5 Ton Unit Left Economizer Duct Opening (inches)
30-3/8
4-5/16
10
Johnson Controls Unitary Products
5123283-TSD-A-0515
3 to 12.5 Ton Unit Roof Curb (inches)
RIGHT
80-5/8
INSULATED DECK UNDER
CONDENSER SECTION
20
SUPPLY
20
6
RETURN
2 TYP.
30
INSULATED DECK UNDER
COMPRESSOR SECTION
50-1/2
FRONT
8 or 14
3 to 12.5 Ton Unit Transition Roof Curb (inches)
2 TYP
50-1/2
30-1/2
23 4
80-5/8
26
RETURN
SUPPLY
10
76-5/8
94
FRONT
Johnson Controls Unitary Products
59-1/4
64-1/4
RIGHT
11
5123283-TSD-A-0515
Economizer Downflow W/Power Exhaust
Fresh Air Hood
Low Leak Economizer
Power Exhaust
Barometric
Relief Damper
Barometric Relief
Hood
Economizer End Return W/Power Exhaust
Fresh Air Hood
Field Installed
Duct Work
Low Leak
Economizer
Power Exhaust
Barometric Relief Damper
Barometric Relief Hood
12
Johnson Controls Unitary Products
5123283-TSD-A-0515
Field Installed Horizontal Economizer W/Power Exhaust
Return Air Damper
Field Installed
Duct Work
Fresh Air Damper
Power Exhaust
Barometric
Relief Damper
Barometric
Relief Hood
Fresh Air Hood
Roof Curb Cutaway
3/4” X 1-1/4” WIDE GASKETING FOR CURB
FRAME AND ALL DUCT SUPPORT SURFACES
2“
UNIT BASE
3.75”
WOOD NAILER
3.56”
UNIT BASE RAILS
14”
8“ MIN. ABOVE FINISHED ROOF
CURB FRAME
COUNTERFLASHING
CAN’T STRIP
INSULATION AND ROOFING MATERIAL
INSULATION
ROOF DECK AND SUPPORT STRUCTURE
Johnson Controls Unitary Products
13
FACTORY INSTALLED OPTIONS
ELECTRIC HEATER MODEL - KW_____VOLTS_____
STAINLESS STEEL HEAT EXCHANGER - - - - - - - - - - 
ALUMINIZED STEEL HEAT EXCHANGER - - - - - - - - - 
STAINLESS STEEL DRAIN PAN- - - - - - - - - - - - - - - - - 
ECONOMIZER, DOWNFLOW, END RETURN HORIZONTAL- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
POWER EXHAUST - - - - - - - - - - - - - - - - - - - - - - - - - - 
MOTORIZED AIR DAMPER - - - - - - - - - - - - - - - - - - - - 
HIGH STATIC INDOOR BLOWER MOTOR - - - - - - - - - 
DISCONNECT SWITCH - - - - - - - - - - - - - - - - - - - - - - - 
CONVENIENCE OUTLET, POWERED - - - - - - - - - - - - 
CONVENIENCE OUTLET, NON-POWERED - - - - - - - - 
SMOKE DETECTOR (RETURN) - - - - - - - - - - - - - - - - - 
SMOKE DETECTOR (SUPPLY) - - - - - - - - - - - - - - - - - 
PHASE MONITOR1 - - - - - - - - - - - - - - - - - - - - - - - - - - 
COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - 
FILTERS, 2" PLEATED, MERV 7 - - - - - - - - - - - - - - - - 
FILTERS, 4" PLEATED, MERV 13 - - - - - - - - - - - - - - - 
PHENOLIC COATED EVAPORATOR COILS - - - - - - - - 
PHENOLIC COATED CONDENSER COILS - - - - - - - - - 
E-COAT EVAPORATOR COILS - - - - - - - - - - - - - - - - - 
E-COAT CONDENSER COILS - - - - - - - - - - - - - - - - - - 
INTELLISPEED WITH VFD - - - - - - - - - - - - - - - - - - - - 
INTELLISPEED, VFD AND MANUAL BYPASS - - - - - - 
INTELLISPEED, VFD READY (FOR CUSTOMER-PROVIDED, FIELD-INSTALLED DRIVE) - - - - - - - - - - - - - - 
VAV W/VFD- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
VAV W/VFD AND MANUAL BYPASS - - - - - - - - - - - - - 
VAV, VFD READY (FOR CUSTOMER-PROVIDED, FIELDINSTALLED DRIVE) - - - - - - - - - - - - - - - - - - - - - - - - - - 
BAS OPTION
Simplicity® Smart Equipment (SSE) w/Communication 
BACnet MS/TP (programmable to Modbus or N2 protocols) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
Honeywell™ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
Novar® - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
CPC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
FIELD INSTALLED ACCESSORIES
ROOF CURB, 8" - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
ROOF CURB, 14"- - - - - - - - - - - - - - - - - - - - - - - - - - - - 
TRANSITION ROOF CURB - - - - - - - - - - - - - - - - - - - - 
COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
HAIL GUARD- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
PERMANENT FILTERS - - - - - - - - - - - - - - - - - - - - - - - 
METAL FILTER FRAME KIT - - - - - - - - - - - - - - - - - - - - 
DIRTY FILTER SWITCH - - - - - - - - - - - - - - - - - - - - - - - 
AIR PROVING SWITCH - - - - - - - - - - - - - - - - - - - - - - - 
BURGLAR BARS (DOWNFLOW ONLY) - - - - - - - - - - - 
LOW AMBIENT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - 
SMOKE DETECTOR (RETURN) - - - - - - - - - - - - - - - - - 
SMOKE DETECTOR (SUPPLY) - - - - - - - - - - - - - - - - - 
CO2 SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
PHASE MONITOR1 - - - - - - - - - - - - - - - - - - - - - - - - - - 
ECONOMIZER, DOWNFLOW, END RETURN HORIZONTAL- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
ECONOMIZER, HORIZONTAL - - - - - - - - - - - - - - - - - - 
SINGLE ENTHALPY- - - - - - - - - - - - - - - - - - - - - - - - - - 
DUAL ENTHALPY - - - - - - - - - - - - - - - - - - - - - - - - - - - 
POWER EXHAUST - - - - - - - - - - - - - - - - - - - - - - - - - - 
MOTORIZED OUTDOOR AIR DAMPER - - - - - - - - - - - 
MANUAL OUTDOOR AIR DAMPER - - - - - - - - - - - - - - 
ELECTRIC HEATER MODEL - KW_____VOLTS_____
FLUE EXTENSION KIT- - - - - - - - - - - - - - - - - - - - - - - - 
GAS PIPING KIT - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
GAS HEAT PROPANE ADAPTER KIT - - - - - - - - - - - - - 
GAS HEAT HIGH ALTITUDE KIT, NATURAL GAS - - - - 
GAS HEAT HIGH ALTITUDE KIT, PROPANE- - - - - - - - 
-60°F GAS HEAT KIT - - - - - - - - - - - - - - - - - - - - - - - - - 
WALL MOUNT TEMPERATURE SENSOR- - - - - - - - - - 
WALL MOUNT TEMPERATURE SENSOR WITH
OVERRIDE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
WALL MOUNT TEMPERATURE SENSOR WITH
OVERRIDE & SET POINT ADJ. - - - - - - - - - - - - - - - - - - 
HUMIDITY SENSOR - - - - - - - - - - - - - - - - - - - - - - - - - 
1. Phase monitor standard on units with scroll compressors.
Subject to change without notice. Printed in U.S.A.