Variable Frequency Drives Table of Contents PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # Variable Frequency Drives Introduction C-3 BT300 HVAC Drives C-5 BT300 NEW! 154-126 BT300 C-15 Legacy SED2 Variable Frequency Drives SED2 154-042 C-19 Legacy SED2 Variable Frequency Drives with Bypass Options SED2 154-044, 154-041 C-23 Legacy SED2 Variable Frequency Drives NEMA Type 3R & Type 3R Harsh Environment Bypass SED2 154-062 C-29 BT300 HVAC Drives with Bypass Options NEW! Accessories & Service Kits C-35 C-1 Variable Frequency Drives www.usa.siemens.com/hvac Variable Frequency Drives C-2 www.usa.siemens.com/hvac Introduction Variable Frequency Drives C-3 While constantly expected to do more with less, managing energy consumption and optimizing occupant comfort remains of utmost importance to facility managers. They also require products that will integrate seamlessly into existing equipment and building management systems. The highly efficient BT300 delivers all this and more. The BT300 comes standard with unique and industry-leading features: • View/Monitor nine parameters at one time – user selectable, users determine the parameters for their applications • Thin Film Capacitors – eliminate the need to condition or reform the capacitors before applying power • Smallest Type 12 footprint on the market – lower shipping cost and easy installation • Motor Switch Ride Through – during maintenance the motor maintenance switch can be opened and closed without stopping or tripping the drive www.usa.siemens.com/hvac Variable Frequency Drives Siemens, a global leader in drives technology, is raising the bar with new BT300 Variable frequency Drives that are designed specifically for the demands of today’s HVAC systems. Increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. Siemens Industry’s BT300 HVAC drives are designed to meet the demands of today’s HVAC systems. An increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. Variable Frequency Drives C-4 We’re happy to assist you Our customer support teams are accessible and happy to assist you with ordering, fulfillment, and shipping questions. Call a representative at 1-800-516-9964 from 7 am to 5:30 pm (CST) Monday through Friday. Contact Customer Support or your Account Executive with any questions. We appreciate your business and look forward to helping you! www.usa.siemens.com/hvac BT300 BT300 Variable Frequency Drives Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. Energy & Atmosphere Description Features • Motor Switch Ride Through – during maintenance the motor maintenance switch can be opened and closed without stopping or tripping the drive • Thin Film Capacitors – eliminate the need to condition or reform the capacitors before applying power • Intuitive graphical keypad with multilingual display • Monitor nine user-defined values at one time • Built-in wizards for faster start-up and easy setup of advanced functions • Integrated harmonic filters on the DC link reduce noise and interference and eliminate the need for additional filters and reactors C-5 • Built in fire mode controller • Energy Savings with > 97.5% efficiency • Optimized cooling fan runs only when needed • Belt failure detection with or without an external sensor • Accepts a wide variety of digital and analog I/O types, including direct Ni 1000 RTD sensor level inputs • One common interface throughout all power ranges • Two form C relays • RoHS Compliant • Smallest Type 12 footprint on the market – lower shipping cost and easy installation Options • LON Interface • Flange Mounting Kits for Frame Sizes 4-7 • Built-in plain text help and maintenance manual shows possible causes and suggested remedies • Varnished I/O Option Boards • Real time clock allows up to five calendar-based schedules and three timer inputs • PC Cable for NET Tool, USB to RS-485, cable length 9.8 ft. (3 m) • Ready to communicate to a Building Management System, embedded RS485 and Ethernet HVAC protocols: BACnet IP, Modbus TCP, Modbus RTU, BACnet MSTP, Metasys N2, APOGEE® FLN • Real Time Clock Battery Package • Door Mounting Kits • SED2 to BT300 Migration Kits • Two built-in PID controllers enable fast and accurate process control www.usa.siemens.com/hvac Variable Frequency Drives Siemens Industry’s BT300 HVAC drives are designed to meet the demands of today’s HVAC systems. An increased focus on energy efficient variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives that reduce the cost of installation and maintenance while maximizing energy savings. HVAC demands are unique to other drive applications. BT300 Variable Frequency Drives without and with Integral Disconnect. BT300 Specifications Variable Frequency Drives C-6 Input Voltage and Power Ranges (3-phase) 208V - 240V, +/-10%.................................. .1 to 125 HP (0.75 to 90 kW) 380V - 480V, +/-10%................................ 1.5 to 250 HP (1.1 to 160 kW) Input Frequency....................................................................... 45 to 66 Hz Output Frequency.................................................................... 0 to 320 Hz Frequency Resolution................................................................... 0.01 Hz Power Factor............................................................ 0.98 at Nominal Load Efficiency ...................................................................................... >97.5% Overload Capacity.................. 1.1 x Nominal Rated Output Current 110% for 1 Minute/10 Minutes Peak Overload Capacity ............200% for 2 Seconds Every 20 Seconds Switching Frequency........ 1.5 to 10kHz; Automatic Switching Frequency Derating in Case of Overheating Short Circuit Withstand Rating.............................................100,000 AIC Frequency Reference Analog Input......0.01 Hz Resolution 0.1% (10-bit) Field Weakening Point............................................................ 8 to 320 Hz Acceleration/Deceleration Time.......................................0.1 to 3000 sec Ambient Operating Temperature......................... -14º F (-10º C) no Frost to 104º F (40º C) Without De-rating and 131º F (55º C) With De-rating Storage Temperature ............................-40º F (-40º C) to 158º F (70º C) Relative Humidity .............0 to 95% RH, Non-condensing, Non-corrosive Air Quality......................................................................... IEC 60068-2-60 Chemical Vapors.................IEC 60721-3-3, Unit in Operation, Class 3C3 Mechanical Particles...........IEC 60721-3-3, Unit in Operation, Class 3S2 Altitude. .......100% Load Capacity (no De-rating) up to 3,280 ft (1,000 m) 1% De-rating for Each 328 ft (100 m) Above 328 ft (1,000 m) Maximum Altitude 14,763 ft (4,500 m) Accessories & Service Kits www.usa.siemens.com/hvac Vibration...............................................IEC 61800-5-1 and IEC 60068-2-6 Shock . .............................................IEC 61800-5-1 and IEC 60068-2-27 Enclosures............................................................. UL Type 1, UL Type 12 EMC Immunity...........Fulfills IEC 61800-3, First and Second Environment EMC Emissions...................................................................EN61800-3C2 Average Noise level (Cooling Fan) Sound Level in dB(A)......................FS4 - 65; FS5 - 61; FS6 and FS7: 68 FR8: 77; FR9: 78 Agency Approvals..................................................UL 508C; CE, UL, cUL Analog Inputs...................... 2 Voltage or Current (0-10Vdc, 0/4 to 20 mA) Analog Output...........................................1 Selectable Voltage or Current Digital Inputs............................................... 6 Programmable and Isolated Relay Outputs.................................................2 Form C; 1 Normally Open Auxiliary Input Voltage.................................24 Vdc +/-10% 250 mA Max. Auxiliary Input Voltage................................24 Vdc +/-10% 250 mA Max., Total of Both Outputs Control Method.........................................................Linear, Parabolic and Programmable V/f; Flux Current Control Low-Power Mode PWM Frequency........... 2k Hz to 16k Hz (Adjustable in 2k Hz Increments) Fixed Frequencies.........................................................15 Programmable Skip Frequency Bands....................................................3 Programmable Embedded Resident Protocols..........................RS485 and Ethernet P1, BACnet MS/TP, BACnet IP, Modbus RTU, Modbus TCP, Metasys N2, APOGEE FLN Protection Features................Under-voltage and Over-voltage Trip Limit, Ground Fault, Mains Supervision, Motor Phase Supervision, Over-current, Unit Over-temperature, Motor Overload, Motor Stall, Motor Underload, Short Circuit of +24V and +10V Reference Voltages C-35 BT300 Product Ordering Your Product Number Example Product Number BT 300 -0 0 1X2 - 01X Example Product Number BT 300 -0 0 154 - 12DL Model BT300VFD only HP 1, 1.5, 2, 3, 5, 7.5, 10, 15 20, 25, 30, 40, 50, 60, 75 100, 125, 150, 200, 250 X 5 No Fract HP, 1/2 HP Voltage 2 4 200 to 240 380 to 480 NEMA 01 12 UL Type 1 UL Type 12 Type X D Drive Only Disconnect Box – ONLY WITH TYPE 12 Options L LON Card Installed C-7 www.usa.siemens.com/hvac Variable Frequency Drives Example Shown: BT300-001X2-01X = 1 HP, 208V Drive in Type 1 enclosure. BT300-00154-12DL = 1.5 HP, 480V Drive in Type 12 enclosure with an integral disconnect switch and LON card. BT300 Output Ratings Voltage (±10%) 208V (3-Phase) Variable Frequency Drives C-8 230V (3-Phase) 380V to 480V (3-Phase) Product Number Output Rating Rated Continuous Current Frame Size UL Type 1 UL Type 12 BT300-001X2-01X BT300-001X2-12X UL Type 12 with Drive Disconnect BT300-001X2-12D 1.0 0.75 4.8 FS4 BT300-00152-01X BT300-00152-12X BT300-00152-12D 1.5 1.1 6.7 FS4 BT300-002X2-01X BT300-002X2-12X BT300-002X2-12D 2.0 1.5 8.0 FS4 BT300-003X2-01X BT300-003X2-12X BT300-003X2-12D 3.0 2.2 11.0 FS4 BT300-005X2-01X BT300-005X2-12X BT300-005X2-12D 5.0 4.0 18.0 FS5 BT300-00752-01X BT300-00752-12X BT300-00752-12D 7.5 5.5 24.0 FS5 BT300-010X2-01X BT300-010X2-12X BT300-010X2-12D 10.0 7.5 31.0 FS5 BT300-015X2-01X BT300-015X2-12X BT300-015X2-12D 15.0 11.0 48.0 FS6 BT300-020X2-01X BT300-020X2-12X BT300-020X2-12D 20.0 15.0 62.0 FS6 BT300-025X2-01X BT300-025X2-12X BT300-025X2-12D 25.0 18.5 75.0 FS7 BT300-030X2-01X BT300-030X2-12X BT300-030X2-12D 30.0 22.0 88.0 FS7 BT300-040X2-01X BT300-040X2-12X BT300-040X2-12D 40.0 30.0 105.0 FS7 BT300-050X2-01X BT300-050X2-12X — 50.0 37.0 140.0 FS8 BT300-060X2-01X BT300-060X2-12X — 60.0 45.0 170.0 FS8 BT300-075X2-01X BT300-075X2-12X — 75.0 55.0 205.0 FS8 BT300-100X2-01X BT300-100X2-12X — 100.0 75.0 261.0 FS9 BT300-125X2-01X BT300-125X2-12X — 125.0 90.0 310.0 FS9 BT300-00154-01X BT300-00154-12X BT300-00152-12D 1.5 1.1 3.7 FS4 BT300-002X4-01X BT300-002X4-12X BT300-002X4-12D 2.0 1.5 5.3 FS4 BT300-003X4-01X BT300-003X4-12X BT300-003X4-12D 3.0 2.2 6.2 FS4 BT300-005X4-01X BT300-005X4-12X BT300-005X4-12D 5.0 4.0 10.6 FS4 BT300-00754-01X BT300-00754-12X BT300-00752-12D 7.5 5.5 13.2 FS4 BT300-010X4-01X BT300-010X4-12X BT300-010X4-12D 10.0 7.5 16.0 FS5 BT300-015X4-01X BT300-015X4-12X BT300-015X4-12D 15.0 11.0 23.0 FS5 BT300-020X4-01X BT300-020X4-12X BT300-020X4-12D 20.0 15.0 31.0 FS5 BT300-025X4-01X BT300-025X4-12X BT300-025X4-12D 25.0 18.5 38.0 FS6 BT300-030X4-01X BT300-030X4-12X BT300-030X4-12D 30.0 22.0 46.0 FS6 BT300-040X4-01X BT300-040X4-12X BT300-040X4-12D 40.0 30.0 61.0 FS6 BT300-050X4-01X BT300-050X4-12X BT300-050X4-12D 50.0 37.0 72.0 FS7 BT300-060X4-01X BT300-060X4-12X BT300-060X4-12D 60.0 45.0 87.0 FS7 BT300-075X4-01X BT300-075X4-12X BT300-075X4-12D 75.0 55.0 105.0 FS7 BT300-100X4-01X BT300-100X4-12X — 100.0 75.0 140.0 FS8 BT300-125X4-01X BT300-125X4-12X — 125.0 90.0 170.0 FS8 BT300-150X4-01X BT300-150X4-12X — 150.0 110.0 205.0 FS8 BT300-200X4-01X BT300-200X4-12X — 200.0 132.0 261.0 FS9 BT300-250X4-01X BT300-250X4-12X — 250.0 160.0 310.0 FS9 www.usa.siemens.com/hvac HP kW 208V 480V KW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 HP 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 Frame Size Voltage BT300 Type 1 and 12 Frame Sizes and Power Range 1 4 N/A 5 6 4 5 7 8 6 7 9 NA 8 9 BT300 Dimensions and Weights Frame Size Height in. (mm) Width in. (mm Depth in. (mm Depth in. (mm FS4 12.9 (328) 5.0 (128) FS5 16.5 (419) FS6 21.9 (557) FS7 FS8 FS9 Weight lb. (kg) (without Disconnect) (with Disconnect) 7.5 (190) 10.6 (270) 13.0 (6) 5.7 (144) 8.4 (214) 11.6 (294) 22.0 (10) 7.7 (195) 9.0 (229) 11.9 (302) 44.0 (20) 26.0 (660) 9.3 (237) 10.2 (259) 13.1 (332) 83.0 (37.5) 38.0 (966) 11.4 (290) 13.5 (343) N/A 145.5 (66) 45.3 (1150) 18.9 (480) 14.4 (365) N/A 238.0 (108) C-9 Variable Frequency Drives www.usa.siemens.com/hvac BT300 Dimensions FS4, Wall-Mount Ø7 (.27) 190 (7.48) 100 (3.93) Ø25 (.98) 328 (12.91) 313 (12.32) 112 (4.40) 151 (5.94) Ø13 (.51) Type 1 / IP21 128 (5.03) Type 12 / IP54 C-10 100 (3.93) Variable Frequency Drives mm (in.) 147 (5.78) 112 (4.40) Ø25 (.98) BT9080 FS5, Wall-Mount www.usa.siemens.com/hvac BT300 Dimensions FS6, Wall-Mount Ø40 (1.57) Ø 15,5 (.61) Ø40 (1.57) 541 (21.29) 557 (21.92) 148 (5.82) Ø9 (.35) Ø33 (1.29) 229 (9.01) 148 (5.82) 151 (5.94) 43,7 (1.72) 195 (7.67) Type 1 / IP21 Ø25 (.98) 148 (5.82) Type 12 / IP54 BT9082 FS7, Wall-Mount 237 (9.33) 190 (7.48) 259 (10.19) Ø20 (.78) Ø9 (.35) Ø16 (.62) Type 1 / IP21 645 (25.39) 211 (8.30) Type 12 / IP54 Ø25 (.98) Ø50 (1.96) 160 (6.29) 217 (8.54) 660 (25.98) 160 (6.29) Ø51 (2) 9083bt mm (in) www.usa.siemens.com/hvac C-11 Variable Frequency Drives mm (in) Ø9 (.35) 151 (5.94) 148 (5.82) 42 (1.65) Ø25 (.98) BT300 Dimensions FS8, Wall-Mount Variable Frequency Drives C-12 www.usa.siemens.com/hvac BT300 Dimensions FS9, Wall-Mount C-13 Variable Frequency Drives www.usa.siemens.com/hvac Variable Frequency Drives C-14 Online 24/7 ordering convenience Use this Master HVAC Catalog and Siemens online ordering to maximize ordering efficiency. Go online to: • Place orders • Browse this catalog online • Check product availability and pricing • Specify FREE valve tagging • Download invoices • Track shipments • Print out product information for submittals • Link to technical documentation • Download installation instructions • Create a reusable template order form for frequently ordered parts See how easy it is to save time and money. Register today at: www.usa.siemens.com/buildingtechnologiesonlineordering www.usa.siemens.com/hvac BT300 BT300 with Bypass Options Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. Energy & Atmosphere BT300 Variable Frequency Drives with Bypass Options. Features The BT300 was designed from the onset with reliability in mind. The BT300 is the first VFD in today’s market which has utilized ALT testing from product design to production deployment. • Contactors electronically interlocked However in today’s market, some customers want additional assurance their equipment will run regardless of the situation. To accommodate these situations, Siemens has developed a companion product for the BT300, the BT300 with Bypass Options. – M1 and M2 contactors – Overload – Customer supplied start/stop – Status of Essential Services As the word indicates, a “bypass” is defined in an engineering spec as a means of taking the drive out of the electrical power loop while keeping the HVAC system up and running. BT300 is available with two types of bypass options. The BT300 with Conventional bypass is designed with 2 contactors and a service switch or the traditional 3-contactor configuration to bypass the drive, and incorporates selector switches and indicator lights to accomplish its primary functions. The second option, an Electronic bypass utilizes internal control boards that act as the brains and eliminates the control wiring, relay logic, terminal blocks and replaces them with advanced built-in features accessible from an electronic keypad. • Advanced diagnostic board built into the bypass for determining status of • Step-down transformer with fused primary and thermal fused secondary circuit • Fused disconnect or circuit breaker Option • 100,000 AIC short circuit rating • Customer Supplied Terminal strip Conventional Bypass Control: • Drive test switch • Drive-Off-Bypass selector • Bypass Light • Fused disconnect or circuit breaker • Optional 2-contactor with service switch or 3-contactor design (input, output and bypass) Electronic Bypass Control • Auto Bypass • Option to install 8 separate safety circuits • Fieldbus in Bypass • Essential Service Mode (Fire mode) • Damper Interlock • Remote start via network www.usa.siemens.com/hvac C-15 Variable Frequency Drives Description BT300 with Bypass Options Product Ordering Your Product Number Example Product Number B T E - 1 2 5 X 4 - B 0 1 2 L Model(s) BTC Conventional BTE Electronic HP 1, 1.5, 2, 3, 5, 7.5,10,15 20, 25, 30, 40, 50, 60, 75 100, 125, 150, 200, 250 X=no fract HP 5= 1/2 hp Voltage 2 200 to 240 4 380 to 480 Disconnect C-16 F Fused Disconnect B Circuit Breaker Enclosure 01 Enclosure Type 1 3 3 contactors (input/output and bypass contactors) (Conventional option only) 2 2 contactors bypass with service switch Options L Lon Card Installed Example shown: BTE -125X4 -B012L BT300 Electronic Bypass, 480 volt, 125hp, Type 1, circuit breaker and 2 Contactor bypass with a service switch and LonWorks card installed in drive BT300 Bypass Options Frame Sizes and Power Ranges 208V 480V KW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 HP 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 Frame Size Voltage Variable Frequency Drives Contactor 1 4 5 N/A 6 4 5 7 8 6 7 9 NA 8 9 Type 1 Bypass Approximate Weights Frame Size 4 5 6 7 8 and 9 Weight lbs. (kg) 50 (23) 69 (31) 112 (51) 187 (85) 1000 (454) www.usa.siemens.com/hvac BT300 Bypass Options Dimensions 35.48 34.625 Frame Size 4 .38 MOUNTING HOLES TYPICAL (4) PLACES .38 1.49 4.000 6.76 35.48 Frame Size 6 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (5) PLACES 34.625 .44 MOUNTING HOLES TYPICAL (4) PLACES .38 MOUNTING HOLES TYPICAL (4) PLACES .38 1.49 4.000 6.76 C-17 54.75 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (5) PLACES 53.750 43.250 Frame Size 5 .38 MOUNTING HOLES TYPICAL (4) PLACES .38 1.49 4.000 6.76 .50 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES 44.10 43.250 3/4" CONDUIT HOLE WITH 1" KNOCKOUT RING TYPICAL (2) PLACES 1.49 6.000 8.76 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES 1-1/4" CONDUIT HOLE WITH 1-1/2" KNOCKOUT RING TYPICAL (2) PLACES .38 1.49 4.000 6.76 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES www.usa.siemens.com/hvac 3/4" CONDUIT HOLE WITH 1" KNOCKOUT RING TYPICAL (2) PLACES Variable Frequency Drives 44.10 BT300 Bypass Options Dimensions Frame Size 7 Frame Size 8 & 9 .50 MOUNTING HOLES TYPICAL (4) PLACES TOP ENTRY, BLANK CONDUIT PLATES 58.50 1.18 TYPICAL (4) PLACES 57.375 Variable Frequency Drives C-18 90.71 .50 4.18 6.000 14.16 1/2" CONDUIT HOLE WITH 3/4" KNOCKOUT RING TYPICAL (3) PLACES 92.99 2" CONDUIT HOLE WITH 2-1/2" KNOCKOUT RING TYPICAL (2) PLACES 32.58 (TYPE 1 & 12) 1.28 29.409 29.409 .94 (4) PLACES TYPICAL www.usa.siemens.com/hvac SED2 Legacy Variable Frequency Drives Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. SED2 Variable Frequency Drives Family. Energy & Atmosphere Features •Built-in SBT P1 and JCI N2 (Metasys®) building automation system protocols for easy network integration •Low harmonics design reduces noise and interference; eliminates need for filters/reactors in most installations •Built-in PID for fast and accurate pressure control •Pump staging for open loop, constant pressure, and constant flow-type applications •Service mode for applications requiring continuous, uninterruptible operation •Accepts a wide variety of digital and analog I/O types, including direct Siemens Ni 1000 RTD sensor level inputs • One common interface throughout all power ranges •Optional Advanced Operator Panel for uploading/ downloading parameters • Full form C relay contacts for digital outputs • Multi-level program access Options •LON Interface •Modbus RTU Interface •Advanced Operator Panel (AOP) Module •PC Kit www.usa.siemens.com/hvac C-19 Variable Frequency Drives •LON, Modbus RTU Interfaces optional • Belt failure detection with or without an external sensor Variable Frequency Drives Specifications Variable Frequency Drives C-20 Input Voltage and Power Ranges (3 phase) 208V and 230V to 240V, 3 ac±10%....................................1 hp to 60 hp 380V to 480V, 3 ac ±10%..................................................1 hp to 125 hp 500V to 600V, 3 ac ±10%..................................................1 hp to 125 hp Input Frequency..................................................................47 Hz to 63 Hz Output Frequency...............................................................0 Hz to 150 Hz Power Factor........................................................................................≥0.9 VFD degree of efficiency....................................................... 96% to 97% Switch-on Current................................... Less than nominal input current Auxiliary Supply 24V........................ Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 mA Overload Capacity....................................................110% for 60 seconds Control Method...........................Linear, parabolic and programmable V/f; and flux current control low-power mode PWM Frequency............2k Hz to 16k Hz (adjustable in 2k Hz increments) Fixed Frequencies......................................................... 15 programmable Skip Frequency Bands.................................................... 4 programmable Setpoint Resolution.............................................................0.01 Hz digital 0.01 Hz serial 10 bit analog Digital Inputs (Sink/Source).............................6: fully programmable and scalable isolated digital inputs, switchable Analog Inputs................................................2: 0 to 10 Vdc, 0/4 to 20 mA, can also be configured as digital inputs or Ni 1000 input Relay Outputs..................................2: configurable 30 Vdc/5A (resistive), 250 Vac/2A (inductive) Analog Outputs..................................2: programmable (0/4 mA to 20 mA, or 0 Vdc to 10 Vdc) Serial Interface..................................................RS-485 transmission rate: Up to 38.4k Baud Protocols: USS, P1 and N2 Protection Level................................................................................. IP20 NEMA Type 1 with protective shield and gland plate installed Temperature Ranges...............Operating: 14°F to 104°F (–10°C to 40°C) Storage: –40°F to 158°F (–40°C to 70°C) Humidity...............................................................95% rh, non-condensing Operational Altitudes..............................................Up to 3280 ft (1000m) above sea level without derating Protection Features.....................Under-voltage, Over-voltage, Overload, Ground fault, Short circuit, Stall prevention, Locked motor, Motor overtemperature l2 t PTC, Over-temperature, Parameter PIN protection. Standards.................................................................... UL, cUL, CE, C-tick CE Conformity.......Conformity with EC Low Voltage Directive 73/23/EEC Options. ........................................ LON Interface, Modbus RTU Interface, BACnet MS/TP Interface, Advanced Operator Panel (AOP) Module, PC Kit Variable Frequency Drives Product Ordering Your Product Number Example Product NumberSED2-0.75/22X Model SED2- VFD only kW rating 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15, 18.5, 22, 30, 37, 45, 55, 75, 90 [See Note 1 for these selections] Voltage 2 3 4 (Uses 2 to 4 spaces plus a divider “/”) 200 to 240V 380 to 480V 500 to 600V NEMA rating 2 (IP 20) 1 NEMA Type 1 Filter X Factory Required Designator Notes: Example Shown: 1. Available only with Voltage Codes 3 and 4. SED2-0.75/22X = SED2 VFD only, 0.75 kW (1 hp), 200 to 240V, open type IP20. www.usa.siemens.com/hvac Variable Frequency Drives Frame Sizes VFD0163R1 SED2 IP20 and NEMA Type 1 Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 kW .75 1.1 1.5 2.2 3 4 240V A 480V B 7.5 10 15 20 25 30 5.5 7.5 11 15 18.5 22 C A D B 575V 40 50 30 37 E C D C 60 75 45 55 100 125 75 90 F N/A E F Variable Frequency Drives Dimensions and Weights IP20 SED2 VFDs Frame Size Height Width Depth Weight Lb. (kg) A 6.8 (173) 2.9 (73) 5.9 (149) 2.9 (1.3) B 8.0 (202) 5.9 (149) 6.8 (172) 7.5 (3.4) C 9.6 (245) 7.3 (185) 7.7 (195) 12 (5.5) D 20.5 (520) 10.8 (275) 9.6 (245) 35 (16) E 25.6 (650) 10.8 (275) 9.6 (245) 44 (20) F 33.5 (850) 13 (350) 12.6 (320) 116 (53) Frame Size Height Width Depth Weight Lb. (kg) A 9.1 (231) 2.9 (73) 5.9 (149) 3.2 (1.5) B 11.8 (300) 5.9 (149) 6.8 (172) 8.3 (3.8) C 13.8 (351) 7.3 (185) 7.7 (195) 13.6 (6.2) D 24.6 (625) 10.8 (275) 9.6 (245) 37.5 (17) E 29.7 (754) 10.8 (275) 9.6 (245) 46.4 (21) F 54.5 (1384) 16.0 (406) 14.0 (356) 200 (91) www.usa.siemens.com/hvac Variable Frequency Drives NEMA Type 1 SED2 VFDs Assembled with Protective Shield and Gland Plate C-21 Variable Frequency Drives C-22 Online order tracking This handy online feature stores all your past and current orders online for quick and easy reference. The Order Tracker function lets you access information such as: • Ordered By • Order No. • Shipping Date • Date Placed • Acknowledgement of Order • Shipment Tracking To view your history and status, register online at www.usa.siemens.com/buildingtechnologiesonlineordering www.usa.siemens.com/hvac SED2 Legacy Variable Frequency Drives with Bypass Options Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. Energy & Atmosphere Bypass Power SED2 Variable Frequency Drives with Conventional Bypass Options Family. 3-Contactor: Input, Output, & Bypass • Overload protection in bypass mode • Step-down transformer with fused primary and secondary • Contactors electrically and mechanically interlocked • Drive test function • Complete electrical isolation of drive Conventional Bypass Control Enable Input •Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Input Device • Fused disconnect • Circuit breaker (optional) • All doors are interlocked and padlockable Input Device Reactor Options • Input line reactor mounted in bypass option enclosure. • Line reactor supplied separately. • Load reactor (in NEMA 1/3R enclosure) supplied separately. VF0302R1 Drive Motor 2 Contactor Bypass Input Device Drive Motor 3 Contactor Bypass E-Bypass Control Auto Bypass •Relay logic allows user to send the motor to bypass mode based on the drive’s programmable relay. •The drive’s programmable relay, typically set to fault, can be set up for applications that run full speed for an extended period of time. Essential Services Mode •Typically used for smoke purge; the motor goes to bypass regardless of the selected mode. •No call to stop will have an effect, including open safety or stop commands. •Only turning the power off or opening this contact will stop the motor. Conventional Bypass – Door Mounted Control Devices • Drive-Off-Bypass selector •Bypass pilot light •Drive Test on/off selector Enable Input •Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote Start/Stop •Common remote start/stop can be used in both drive and bypass mode. www.usa.siemens.com/hvac C-23 Variable Frequency Drives Essential Services Mode •Also used for smoke purge; the motor goes to bypass regardless of the selected mode. •No call to stop will have an effect, including open safety or stop commands. •Only turning the power off or opening this contact will stop the motor. Variable Frequency Drives with Conventional Bypass Option Specifications Electronic Bypass Specifications Conventional Bypass Specifications Input Voltage (3-phase) 208V, 3 AC±10%..........................1 hp to 60 hp (2.3 amps to 154 amps) 240V, 3 AC±10%..........................1 hp to 60 hp (2.3 amps to 154 amps) 480V, 3 AC ±10%.......................1 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10%.......................1 hp to 125 hp (2.3 amps to 125 amps) Protection Level...................................................................NEMA Type 1 Digital Inputs Six Digital Inputs as follows...........Remote start input, Remote safety 1, Remote safety 2, Interlock start, Essential services, Overload trigger. Inputs require a contact closure capable of providing a low impedance path at currents less than 20 mA. Relay/Digital Outputs Six Relay/Digital Outputs as follows.........................................VFD fault, Programmable output, Drive select, Bypass select, Running on bypass, Overload fault, Each relay has a maximum rating of 2A at 120Vac. Input Voltage (3-phase) 208V, 3 AC±10%..........................1 hp to 60 hp (2.3 amps to 154 amps) 240V, 3 AC±10%..........................1 hp to 60 hp (2.3 amps to 154 amps) 480V, 3 AC ±10%.......................1 hp to 125 hp (1.2 amps to 178 amps) 575V, 3 AC ±10%.......................1 hp to 125 hp (2.3 amps to 125 amps) Protection Level...................................................................NEMA Type 1 Temperature Operating......................................................... 32 to 104°F (0 to +40°C) Storage.......................................................-40 to +158°F (-40 to +70°C) Humidity......................................................0 to 95% RH, non-condensing E-Bypass — Door Mounted Control Devices C-24 VFD Variable Frequency Drives Input On/Off Bypass Hand Start Input Contactor VFD Bypass Contactor Remote Start Enable Output Contactor Overload Relay Motor VFD0097R2 STOP RESET Accessories & Service Kits www.usa.siemens.com/hvac Auto Bypass Enabled Essential Services INTERLOCK START LOGIC VFD Fault Safety Fault Overload Fault Enable Commanded Proofed C-35 Legacy Variable Frequency Drives with Conventional Bypass Option Product Ordering Your Product Number Example Product Number Model VB VBA340 .B133X VFD with an Extended Box Series AConventional Bypass E Electronic Bypass Voltage 1 2 3 4 208 V 230 to 240 V 380 to 480 V 500 to 600 V HP rating 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 125 [See Note 1 for these selections] Fused Disconnect Circuit Breaker NEMA rating 1 NEMA Type 1 Contactor 3 0 3 Contactors (Input, output, and bypass contactors) None (Extended box only. No bypass.) Reactor 0 3 [See Note 3] None Line Reactor Filter X Factory Required Designator C-25 Notes: 1. Available only with Voltage Codes 3 and 4. 2. Input line reactors will be installed in bypass enclosures. Load reactors are supplied seperately in NEMA 1 or NEMA 3R enclosures. Example shown: VBA340.B133X VBA Conventional Bypass, 40 HP, 480V, Circuit Breaker, NEMA Type 1, 3-Contactor Bypass with Input Line Reactor. VBE340.F130X VBE Electronic Bypass, 40 hp, 480V, fused disconnect, NEMA Type 1, 3 contactors bypass, no reactor. www.usa.siemens.com/hvac Variable Frequency Drives Disconnect F B NEMA 1 Bypass Approximate Weights Frame Size Wt. Lb (kg) A 45 (20) B 55 (25) C 75 (34) D 150 (68) E 180 (82) F 470 (213) Note: Exact weight will be affected by the actual horsepower/voltage and the selected power options. NEMA 1 Bypass Frame Sizes and Power Ranges Variable Frequency Drives C-26 HP kW 208/240V 1 .75 A 1.5 1.1 2 1.5 3 2.2 5 4 7.5 5.5 10 7.5 15 11 20 15 25 18.5 30 22 40 30 50 37 60 45 75 55 100 75 125 90 HA1 — 480V 575V A B B C C C D E F N/A D D E E F F N/A www.usa.siemens.com/hvac NEMA 1 Dimensions Depth With 20.8 2.9 Handle (53) (7.4) 4 10.4 (26) (10) 1 Depth 20.8 2.9 (2.5) 2With (5) Handle (53) (7.4) 4 = Protective Shield Depth With Handle 9.6 (24) Depth = Protective Shield Depth With Handle Depth 9.6 (24) With Handle 1.5 9.6 (24) 13.2 (34) With Handle 9.6 (24) 11.5 (29) 11.5 (29) (3.8) 10.4 (26) 1 (2.5) 2 (5) 1.5 (3.8) 13.2 (34) 53.5 (136) 48 (122) 34 (86) 53.5 (136) 48 34 (86) 10.5 TYP (122) (27) 12.4 (31) 12.4 10.6 (27) (3.8) 10.6 1.5 12.2 (31) 20.8 (53) 20.8 (53) 2 (5) 19.9 (51) (5) 19.9 3.4 (51) Frame (8.6) 2.9 3 3.4 (8.6) Size D Frame Size D Size C (7.4) 2.9 (7.4) 3(7.6) (7.6) 11.5 TYP (29) C-27 Depth Depth17.4 17.4 (44) 45.5 (116) 45.5 (116) (44) 57.5 57.5 (146) (146) 58.5 58.5 (149) (149) 10 TYP VFD0127R2 VFD0127R2 10 TYP (25) (25) 19.9 19.9 (51) (51) 5.5 5.5 (14) (14) FrameSize SizeEE Frame Frame Size Frame Size F F Dimensions shown in inches (mm). www.usa.siemens.com/hvac Variable Frequency Drives Depth With Depth Handle With 12.2 (31) Handle 11 TYP (28)2 (27) Frame Size C Frame A and B 11.5 TYP (29) 11 TYP (28) 10.5 TYP 1.5 (27) (31) Size (3.8) Frame A and B Frame Size (10) Variable Frequency Drives C-28 We’re happy to assist you Our customer support teams are accessible and happy to assist you with ordering, fulfillment, and shipping questions. Call a representative at 1-800-516-9964 from 7 am to 5:30 pm (CST) Monday through Friday. Contact Customer Support or your Account Executive with any questions. We appreciate your business and look forward to helping you! www.usa.siemens.com/hvac SED2 Legacy VFD NEMA Type 3R & Type 3R Harsh Environment (3RHE) Bypass Energy & Atmosphere Important Note: VFD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies representative at: 1.800.516.9964. SED2 Variable Frequency Drives NEMA Type 3R Bypass. Features Bypass – Door Mounted Control Devices Bypass Power •Drive-Off-Bypass selector •Bypass pilot light •Drive Test On-Off selector Variable Frequency Drives 3-Contactor: Input, Output, and Bypass • Overload protection in bypass mode. •Step-down transformer with fused primary and secondary. • Contactors electrically and mechanically interlocked. • Drive test function. • Complete electrical isolation of drive. C-29 Input Device • Fused disconnect. • All doors are interlocked and padlockable. Reactor Options • Line reactor mounted in bypass enclosure. •Line reactor supplied separately (in NEMA Type 3R enclosure). •Load reactor supplied separately. www.usa.siemens.com/hvac NEMA Type 3R/3RHE Bypass Specifications Input Voltage (3 phase)............................................... 208V, 3 AC ±10% * 240V, 3 AC ±10% * 480V, 3 AC ±10% 575V, 3 AC ±10%* * Not available in the 3RHE models Protection Level ...............................................................NEMA Type 3R Temperature Operating.............14°F to 104°F (–10°C to 40°C), HT1 to 122°F (50°C) Storage..................................................–40°F to 158°F (–40°C to 70°C) High-Temperature Model (HT1 and HT2) Operating................................................14°F to 122°F (–10°C to 50°C) Storage................................................. –40°F to 158°F (–40°C to 70°C) Humidity........................................................0 to 95% rh, non-condensing Variable Frequency Drives C-30 www.usa.siemens.com/hvac VFD NEMA Type 3R & Type 3R Harsh Environment (3RHE) Bypass Product Ordering Your Product Number Example Product Number VBA340 . F330XHE2 Model VB VFD with an Extended Box Series A Conventional Bypass Voltage 1 2 3 4 208 V 230 to 240 V 380 to 480 V 500 to 600 V HP rating 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 100, 125 [See Note 1 for these selections] Disconnect F Fused Disconnect C-31 NEMA Type 3R Contactor 0 3 None 3 Contactors (Input, output, and bypass) Reactor 0 3 [See Note 2] None Line Reactor Filter X Factory Required Designator Options HT1 HE2 HT2 (If no option is required, leave field blank) High Temperature [See note 3] Harsh Enviroment Nema 3R [See note 4] Harsh Enviroment Nema 3R — High Temperature Rating [See note 5] Notes: 1. Available only with Voltage Codes 3 and 4. 2. Input line reactors will be installed in bypass enclosures. Load reactors are supplied seperately in NEMA 1 or NEMA 3R enclosures. 3. HT1 (122°F, 50°C) is not available for all ratings. 208V and 230 to 240V to 3 hp are all HT1; 480V to 5 hp are all HT1. 4. HE2 available only with Voltage Codes 3 and 4. (480V to 40 hp) 5. HT2 (122°F, 50°C) is not available for all ratings. 480V to 5 hp are all HT2 Example Shown: VBA340.F330XHE2 VBA Conventional Bypass, 480V, 40 hp, fused disconnect, NEMA Type 3R, 3 contactors, no reactor, harsh environment. www.usa.siemens.com/hvac Variable Frequency Drives NEMA rating 3 NEMA Type 3R Enclosure Dimensions Enclosure Frame ABC ENCLOSURE FRAME ABC Enclosure Frame ENCLOSURE FRAMEDE DE Enclosure Frame F F ENCLOSURE FRAME 46 (1169) 30 (762) 34 (864) 18 (457) 58 (1473) 42 (1067) 30 (762) 28-1/2 (724) 57 (1448) 75 (1905) 56-1/8 (1425) 74-1/8 (1882) MOUNTING CLEARANCE DepthDEPTH = 12-1/2 Inches = 12-1/2 (318)(318) FOR PROPER AIRFLOW: LEAVE 1 FOOT (305 mm) BETWEEN THE NEMA TYPE 3R BYPASS AND ANY ADJACENT SOLID STRUCTURE THAT IS NOT USED FOR MOUNTING PURPOSES. 16-1/2 (419) Depth =DEPTH 16-1/2= Inches (419) LEAVE 3 FEET (914 mm) BETWEEN THE NEMA TYPE 3R BYPASS AND ANY OTHER NEMA TYPE 3R BYPASS OR VFD. NEMA Type 3RHE Enclosure Dimensions Enclosure Frame B Enclosure Frame C Enclosure Frame D 44 (1099) 42 (1051) 28 (711) 26 (660) 34 (848) 18 (457) 51 (1288) 57 (1440) 50 (1272) 30 (756) 56 (1424) 29 (724) Depth = 10 Inches VFD0228R1 VFD0225R1 VFD0222R1 Variable Frequency Drives C-32 VFD0178R2 11-1/2 (292) Depth = DEPTH 11-1/2=Inches (292) Depth = 11 Inches Dimensions shown in inches (mm). www.usa.siemens.com/hvac Depth = 14 Inches NEMA Type 3R and 3RHE Approximate Weights 3R Frame Size Wt. Lb (kg) 3RHE Frame Size ABC 130 (59) B Wt. Lb (kg) 150 (68) DE 300 (136) C 220 (100) F 550 (249) D 330 (150) Note: Exact weight will be affected by actual horsepower/voltage and selected power options NEMA Type 3R Bypass Non-HT1 Enclosure Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 VFD0179R2 208/240V (Rated as HT1, High Temperature package) ABC DE (Rated as HT1, High Temperature package) 480V 575V F ABC ABC N/A DE F DE F C-33 VFD0180R2 HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 208/240V ABC DE 480V F ABC 575V N/A DE ABC F DE N/A F N/A VFD0180R2 NEMA 3RHE Bypasses HE2 Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 7.5 10 15 kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 208/240V 20 25 30 40 50 60 75 100 125 15 18.5 22 30 37 45 55 75 90 N/A 480V N/A C D 575V N/A N/A VFD0180R2 NEMA 3RHE Bypasses HT2 Frame Sizes and Power Ranges HP 1 1.5 2 3 4 5 7.5 10 15 20 25 30 40 50 60 75 100 125 kW .75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 208/240V 480V 575V N/A N/A B C D N/A N/A www.usa.siemens.com/hvac Variable Frequency Drives NEMA Type 3R Bypass HT1 Enclosure Frame Sizes and Power Ranges Variable Frequency Drives C-34 Online 24/7 ordering convenience Use this Master HVAC Catalog and Siemens online ordering to maximize ordering efficiency. Go online to: • Place orders • Browse this catalog online • Check product availability and pricing • Specify FREE valve tagging • Download invoices • Track shipments • Print out product information for submittals • Link to technical documentation • Download installation instructions • Create a reusable template order form for frequently ordered parts See how easy it is to save time and money. Register today at: www.usa.siemens.com/buildingtechnologiesonlineordering www.usa.siemens.com/hvac Accessories & Service Kits Table of Contents PRODUCT BT300 PAGE # NEW! PC Cable for Software Tools C-36 Real Time Clock Battery Package C-36 Door Panel Kit C-36 Hand Held Panel Kit C-36 Flange Mounting Kits C-36 Varnished Option Boards C-37 SED2 to BT300 Migration Kits C-38 SED2 C-39 Mounting Hardware C-39 Filter Kits C-39 Operator Panel C-39 LON Interface Option C-40 Modbus Interface C-40 www.usa.siemens.com/hvac C-35 Variable Frequency Drives PC Kit Accessories and Service Kits Description Part No. BT300 PC Cable for Software Tools, USB to RS-485, 3m BT300-CABLE Battery package, 5 pcs BT300-BATTERY Door Panel Kit, Drive Side IP54 Protected, 3m BT300-PANEL-N12 Hand Held Panel Kit BT300-HHPANEL Flange Mounting Kit, for FS4 BT300-FLG-FS4 Flange Mounting Kit, for FS5 BT300-FLG-FS5 Flange Mounting Kit, for FS6 BT300-FLG-FS6 Flange Mounting Kit, for FS7 BT300-FLG-FS7 Variable Frequency Drives C-36 www.usa.siemens.com/hvac Description Part No. BT300 6 X DI/DO, Programmable BT300-OPT-B1-V 2 X RO + Thermistor BT300-OPT-B2-V 1 X AI, 2 X AO (Isolated) BT300-OPT-B4-V C-37 BT300-OPT-B5-V 1 X RO, 5 X DI (42-240VAC) BT300-OPT-B9-V LonWorks BT300-OPT-C4-V 1xAO, 1xDO, 1xRO BT300-OPT-BF-V NI1000 Sensor Card BT300-OPT-BH-V www.usa.siemens.com/hvac Variable Frequency Drives 3 X RO Accessories and Service Kits Description Part No. BT300 Variable Frequency Drives C-38 www.usa.siemens.com/hvac SED2 208V to 3HP 480V to 5HP SED2-BT300-AB-4 SED2 208V to 4HP 480V to 7.5HP SED2-BT300-C-4 SED2 208V to 10HP 480V to 20HP SED2-BT300-C-5 SED2 208V 15 to 20hp 480V 25 to 40hp SED2-BT300-D-6 SED2 208V 25hp SED2-BT300-D-7 SED2 208V 30hp 480V 50 to 60hp SED2-BT300-E-7 SED2 FSC to BT300 Remote Mount SED2-BT300-C-R SED2 FSD and FSE to BT300 Remote Mount SED2-BT300-DE-R SED2 208V 40hp 480V 75hp SED2-BT300-F-7 SED2 208V 50 to 60hp 480V 100 to 125hp SED2-BT300-F-8 Description Part No. SED2 PC Kit. SED2-PC-KIT Gland Plates. (included with NEMA Type 1) • Frame A SED2-GL-A • Frame B SED2-GL-B • Frame C SED2-GL-C Protection Shield. (included with NEMA Type 1) SED2-PS-A • Frame B SED2-PS-B • Frame C SED2-PS-C • Frame D, E SED2-PS-DE NEMA Type 1 and 3R Enclosed Reactors. Contact Sales Partners NEMA Type 3R Floor Mounting Kit. • Frames A, B, C 994-809 BOP/AOP Door Mounting Kits. • BOP/AOP Single Inverter SED2-DOOR-KIT1 • AOP Multi-Inverter SED2-DOOR-KIT2 Operator Panel. • Basic Operator Panel (included with all SED2s) SED2-BOP1 • Advanced Operator Panel (AOP) SED2-AOP1 www.usa.siemens.com/hvac C-39 Variable Frequency Drives • Frame A Accessories and Service Kits Description Part No. SED2 Variable Frequency Drives C-40 www.usa.siemens.com/hvac LON Interface Option. SED2-LONI/F Modbus RTU Interface Module for SED2. SED2-MODBUS2 SED2 Modbus Configuration Kit. SED2-MODBUS2_KIT