Installation Instructions for 920E6RLI-I Round or Square Type IC Housing for Regressed Flangeless Trims, with Incandescent Lamp E6_LR-II-_ 1.0 INCANDESCENT - ROUND/SQUARE FLANGELESS GENERAL PRODUCT INFORMATION: This product is suitable for wet locations. This product can be dimmed with a standard incandescent dimmer. CAUTION - RISK OF FIRE This instruction shows a typical installation. This product requires installation by a qualified electrician. Before installing be sure to read all instructions and DISCONNECT POWER TO THE ELECTRICAL BOX. Install the Housing with Adjustable Bars 1A 1B HOUSING JOIST NAIL NAIL 2 5 1 5 INNER ADJUSTABLE BAR HOUSING CLASP OUTER ADJUSTABLE BAR 4 STOP POINT TRIM HOLDER 5 2 4 TAB NOTE: If using the butterfly brackets, omit these NOTE: The adjustable bars can be mounted to steps and refer to "Install the Housing with Butterfly Brackets" on page 2. joists that are spaced 16" - 24" apart. NOTE: The trim holder is 1/2” high. When 1 Slide the inner adjustable bar completely through the three housing clasps. Make sure that the attached nail is located on top. 2 Slide and push the outer adjustable bar completely onto the inner adjustable bar so that the tab clicks into place behind the stop point. This will prevent the adjustable bars from coming apart. 3 installing the adjustable bars to joists, make sure the bottom of the trim holder matches with bottom of the drywall. Repeat steps 1 & 2 for the other side of the housing. 1 4 Align the adjustable bars so that the trim holder is exposed below the joists just enough to match with the drywall thickness. 5 Level the adjustable bars and, with a hammer, tap the nails completely into the joists to secure the adjustable bars in place. Install the Housing with Butterfly Brackets 1C 2B 6 SLOT HOUSING ADJUSTABLE BAR 2 WING NUT TRIM HOLDER BEVELED CORNER 1 BUTTERFLY BRACKET NOTCH NOTE: Skip to Page 3 if installing the housing with adjustable bars. 7 NOTCH 1 Loosen (Do not remove) the wing nut. 2 Slip the button head screw through the large opening in the housing slot. Make sure the beveled corners of the butterfly bracket are toward the bottom of the housing. 3 Slide the butterfly bracket within the slot to the desired height, and tighten the wing nut to secure the bracket. 4 Repeat steps 1-3 for the other side. 5 Use the butterfly brackets to mount the housing, according to local building codes and electrical codes. HOUSING TRIM HOLDER SELF TAPPING SCREW 6 7 7 NOTE: Notches in trim holder can be used to Adjust the horizontal position of the trim holder by sliding the housing on adjustable bars. align multiple housings using a laser or string. When the desired location is achieved, tighten the two selftapping screws to lock the housing onto the adjustable bars. NOTE: Notches in trim holder can be used to align multiple housings using a laser or string. 2 Connect Power to the Housing 3C 3A TABS 6 ELECTRICAL BOX COVER 1 4 5 Push up the tabs on the electrical box and remove the electrical box cover. 1 4 Connect the neutral power line wire to the white fixture wire with the included lever nut. 5 Connect the black fixture wire to the hot power line wire with the included lever nut. 6 Connect the bare wire to a suitable ground according to local electrical codes. 7 Replace the electrical box cover. Make sure that the top edge of the cover snaps under the tabs. 3B CONDUIT 2 NOTE: Before installing insulation, drywall, or acoustic panel, power up and run the Element fixture(s) for 10 minutes to make sure that all electrical connections are tight and secure. Refer to page 6 to install the lamp. 2 Install the conduit to the housing electrical box. 3 Run the power line wires into the housing electrical box. WARNING: RISK OF FIRE. When using the housing electrical box for power feed through, use MAX 8 - #12 AWG branch circuit wires. 3 Install Drywall 4C 4A 6-3/8" 1a TAB TAB 6-3/8" 1b 3 3 3 3 ROUND PLASTER RING ROUND TRIM HOLDER 1a SQUARE PLASTER RING SQUARE TRIM HOLDER For housings with round trim holder, mark a 6-3/8" diameter circle on drywall or acoustic panel. Cut out the marked section. 1b For housings with square trim holder, mark a 6-3/8" square 4 on drywall or acoustic panel. Cut out the marked section. 4B 3 3 CUT OUT 4 3 3 CUT OUT 3 Line up the two tabs in back of the plaster ring with the two cut out sections of the trim holder inside edge. 4 Push the plaster ring tabs into the cut out sections of the trim holder edge. DRYWALL 2 Align the cut out section of drywall or acoustic panel with the trim holder and install drywall (or acoustic panel). 4 4D #8-32 SCREW 5 5 8 NOTE: Do not overtighten the screws! Overtightening may bend the plaster ring, causing the plaster surface to come away from the drywall. 4E LENS LOCK LENS LOCK 6 6 Plug the trim holder with the provided dust shield. 7 Properly plaster onto the plaster ring and drywall. 5 Finish around the trim to match drywall. LENS LOCK 8 5 Secure the plaster ring in place with the two provided flat head #8-32 screws. Make sure that the screws penetrate through the drywall into the housing screw holes. 6 LENS LOCK 8 LENS LOCK LENS LOCK 5 5 4F #8-32 SCREW Install the Trim and Lamp 5C 5A CLIP CLIP REFLECTOR REFLECTOR 1 3 NOTE: This section illustrates a square trim. Round trim pieces install the same way. 1 Turn the reflector clips 90 degrees and lower the reflector from the fixture. Use a flathead screwdriver or pliers to turn the clips if they are too difficult to turn by hand. 3 Return the reflector to the housing and turn the clips 90 degrees to secure it. 5D 5B LAMP HOOP (INSIDE) 4 CARABINER 4 Screw the lamp completely into the socket. SAFETY CABLE Use MAX 90 Watt Medium Base Incandescent Lamp. HOOP 2 CARABINER SAFETY CABLE 2 Clip the carabiner onto the hoop inside the housing. 6 SAFETY CABLE Replacing the Lamp 5E 6A LENS 5 1 5 Line up the trim with the trim holder, and push the trim completely into the trim holder. Arrows on the trim and in the trim holder indicate the proper orientation. LIP 1 Push up slightly on the lens to reveal the inside lip. 2 Grab the trim by the lip and pull the trim out of the trim holder. 3 Unscrew the lamp and follow steps 4-5 in section 5 to replace the lamp. SAVE THESE INSTRUCTIONS! 7 7400 Linder Ave, Skokie, IL 60077 847.410.4400 www.element-lighting.com © 2008 Tech Lighting, L.L.C. All rights reserved. The "Element" graphic is a registered trademark of Element. Element reserves the right to change specifications for product improvements without notification. A Generation Brands Company 8