Baseefa Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ United Kingdom ANNEX to IECEx BAS 12.0099 Issue No. 0 Date: 2012/12/06 1. Apparatus that may be installed in a Non Hazardous Area (Safe Area) 1.1. Shunt Zener Diode Safety Barriers or Galvanic Isolators coded [Ex ia Ga] IIC and for connection as follows: 1.1.1. To AE Coupler Type 5125C Power Supply (J7) One (1) Turck Solenoid Driver Type IM72-11Ex/L to IECEx BAS 05.0011X or One (1) MTL MTL7722+ Shunt Zener Diode Safety Barrier to IECEx BAS 04.0025 1.1.2. To AE Coupler Type 5125C 0-10V DC Analog (J11, pins 1 & 2) One (1) Turck Analogue Data Transmitter Type IM31-11-Ex-U to IECEx TUN 06.0011X or One (1) MTL MTL7722+ Shunt Zener Diode Safety Barrier to IECEx BAS 04.0025 1.1.3. To AE Coupler Type 5125C 4-20mA Analog (J11, pins 3 & 4) One (1) Turck Analogue Data Transmitter Type IM31-11-Ex-I to IECEx TUN 06.0011X 1.1.4. To AE Coupler Type 5125C Alarm Switch (J8) One (1) Turck Isolating Switch Amplifier Type IM1-12Ex-R to IECEx TUN 06.0006X or One (1) MTL MTL7710+ Shunt Zener Diode Safety Barrier to IECEx BAS 04.0025 1.2. The above apparatus is to be supplied from apparatus situated in the safe area which is unspecified except that it must not be supplied from nor contain in normal or abnormal conditions a source of potential with respect to earth in excess of 253 volts r.m.s. or 253 volts d.c. 2. Apparatus that may be installed in a Hazardous Area 2.1. 2.2. One (1) Acoustic Emission Coupler Type 5125C to IECEx BAS 12.0087X. One (1) Type 8152C AE Sensor to IECEx BAS 12.0116X. 3. 3.1. 3.1.1. Permissible Interconnecting Cables Non-Hazardous Area to Hazardous Area (Barrier / isolator to AE Coupler Type 5125C) Type 5125C Power Supply (J7) 3.1.1.1. Turck Solenoid Driver Type IM72-11Ex/L Uo = 17.6V; Io = 96mA; Po = 678mW The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA C μF 0.333 1.930 8.100 L mH 3.86 15.43 30.86 Page 1 of 3 OR L/R Ratio μH/Ω 52 209 418 Baseefa Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ United Kingdom ANNEX to IECEx BAS 12.0099 Issue No. 0 Date: 2012/12/06 3.1.1.2 MTL MTL7722+ Shunt Zener Diode Safety Barrier Uo = 22V; Io = 147mA; Po = 0.81W The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA C μF 0.165 1.140 4.200 L mH 1.65 7.22 14 OR L/R Ratio μH/Ω 44 176 353 3.1.2. Type 5125C 0-10V DC Analog (J11, pins 1 & 2) 3.1.2.1. Turck Analogue Data Transmitter Type IM31-11-Ex-U Uo = 7.2V; Io = 1mA; Po = 2mW The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA C μF 13.50 240.0 1000 L mH 1000 1000 1000 OR L/R Ratio μH/Ω 1000 1000 1000 3.1.2.2 MTL MTL7722+ Shunt Zener Diode Safety Barrier Uo = 22V; Io = 147mA; Po = 0.81W The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA C μF 0.165 1.140 4.200 L mH 1.65 7.22 14 OR L/R Ratio μH/Ω 44 176 353 3.1.3. Type 5125C 4-20mA Analog (J11, pins 3 & 4) 3.1.3.1. Turck Analogue Data Transmitter Type IM31-11-Ex-I Uo = 7.2V; Io = 1mA; Po = 2mW The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA C μF 13.50 240.0 1000 L mH 1000 1000 1000 Page 2 of 3 OR L/R Ratio μH/Ω 1000 1000 1000 Baseefa Rockhead Business Park Staden lane, Buxton, Derbyshire SK17 9RZ United Kingdom ANNEX to IECEx BAS 12.0099 Issue No. 0 Date: 2012/12/06 3.1.4. Type 5125C Alarm Switch (J8) 3.1.4.1. Turck Isolating Switch Amplifier Type IM1-12Ex-R Uo = 9.6V; Io = 11mA; Po = 26mW The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA C μF 3.60 26.0 210.0 L mH 290 1000 1000 OR L/R Ratio μH/Ω 1000 1000 1000 3.1.4.2 MTL MTL7710+ Shunt Zener Diode Safety Barrier Uo = 10V; Io = 200mA; Po = 0.5W The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA 3.2. 3.2.1. C μF 3.00 20.0 100.0 L mH 0.91 2.72 7.25 OR L/R Ratio μH/Ω 71 284 569 Hazardous Area (AE Coupler Type 5125C to Type 8152C AE Sensor) Type 5125C AE Sensor Out (J4) Uo = 11.6V; Io = 25.5mA; Po = 74mW The capacitance and either the inductance or the inductance to resistance ratio (L/R) of the hazardous area cables must not exceed the following values:Group IIC IIB IIA 3.3. C μF 1.59 10.8 43.0 L mH 54 215 430 OR L/R Ratio μH/Ω 480 1925 3855 Wiring to terminals of the safe area apparatus may be achieved by separate cables or by separate circuits within a Type A or Type B multicore cable (as defined in clause 9 of EN 60079-25:2010) subject to the following:a. b. The circuit to be individually screened when used within a Type A multicore cable. The peak voltage of any other circuit within a Type B multicore cable must not exceed 60V. Page 3 of 3