quickstart guide P-CBI 1 Prodigy® Wireless Keypad 1Introduction The Prodigy® P-CBI is an elegant yet robust in-wall keypad providing simple direct control of lighting or devices, utilizing mesh network technology of 802.15.4 affording reliable communications and load control without the need to run additional control system wiring. 2 Application The following diagram illustrates a P-CBI in a system with other Prodigy devices. 3 Assembly The P-CBI is supplied partially assembled along with several items as listed in the following table. USE ITEM 1. Make sure the light masks are correctly positioned. The light masks will not fall out of their locations, but can easily be removed and/or relocated as necessary. 2. Attach the button strips to the housing assembly according to the way the unit is programmed. The button strips are held in place by three mounting posts. QTY Rear housing with switch circuitry and light masks attached Body of P-CBI 1 Bezel Assembly Holds button caps in position on rear housing 1 Screws, steel, flat Phillips head, 4B x 3/4” Attach the mounting plate to the electrical box 2 Two-button cap strip Provides two large-size buttons 2 Three-button cap strip Provides three medium-size buttons 2 Six-button cap strip Provides six small-size buttons 2 Mounting plate Mounts to electrical box and provides mounting point for P-CBI 1 Screws, steel, Phillips, pan head, 04-40 x 1/4” Attach the assembled keypad to the mounting plate 4 Removal Assembly Light Masks Small Flatblade Screwdriver Button Strip Mounting Posts 3-Button Strip 6-Button Strip 3. If the button strips need to be changed or replaced, insert a flat blade screwdriver into the notches provided and carefully pry the button strip up and off the mounting posts. 4. Using the Phillips screwdriver, attach the mounting plate to the electrical box as shown in the illustration below. The following items are required for assembly and installation: • Phillips screwdriver (not supplied) • Flat blade screwdriver (not supplied) NOTE: The mounting plate can be attached as shown, or can be rotated 90° if necessary to accommodate the orientation of the electrical box. Light masks are used to reduce the backlight intensity between the buttons. The housing assembly is shipped with light masks in place for two six-button cap strips. UK-Style Electrical Box Mounting Plate Screws 4B X 3/4” For Regulatory Compliance information, refer to the latest version of Doc. 7073. QUICKSTART DOC. 7072A (2028707) 07.10 www.crestron.com/prodigy ©2010 Specifications subject to change without notice. 888.273.7876 201.767.3400 All brand names, product names, and trademarks are the property of their respective owners. P-CBI When using two- or three-button cap strips, remove the extra light masks. Use one light mask for two-button strips, two masks for three-button strips, and five masks for six-button strips. (Retain the extra light masks in case the keypad is reprogrammed for a different configuration.) Refer to the illustration in the following column. 1 Notch quickstart guide P-CBI Prodigy® Wireless Keypad 1 1 6 Acquire the P-CBI 4 1 1 4 Hardware Hookup Use the following procedure to connect the keypad to an electrical circuit. 1. Turn AC power OFF. WARNING: Turn off power at the circuit breaker. Installing with power on can result in serious personal injury and damage to the device. ! NOTE: Refer to the following diagram when making connections to the device. No Yes Do Not Insert Wires Behind Screw Head. Insert Wires Into Wire Entry Holes. 2. Connect the AC power cable to the line, neutral, and ground terminals on the keypad assembly following all local codes. 51 4 Installation Use the following procedure to install the keypad in an electrical box. 1. Push the wires into the electrical box and attach the keypad assembly to the mounting plate as shown in the following illustration. ! CAUTION: Excess wire pinched between the keypad and electrical box could cause a short circuit. Make sure that all excess wire is completely inside the electrical box and not between the box and the keypad. Mounting Plate Keypad Assembly Bezel 2. Attach the bezel by putting it in position over the button caps and snapping it in place. 3. Turn AC power ON. 2 For Regulatory Compliance information, refer to the latest version of Doc. 7073. QUICKSTART DOC. 7072A (2028707) 07.10 7 Troubleshooting Use the Prodigy Composer software to configure your Prodigy system (refer to the online help for detailed information). The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. NOTE: The Prodigy Composer software is available for download from www.crestron.com/prodigycomposer. Before a P-CBI can be used, it must first be acquired by the P-MNETGW gateway that is connected to a Prodigy system. When prompted by the Prodigy Network Setup Wizard within Prodigy Composer to physically put detected devices into Acquire mode, it is recommended that you start with the device that is closest to the gateway. As each device is acquired by the gateway, the device functions as a repeater to reinforce the network. TROUBLE The keypad does not function. All LEDs blink four times after button press. To place the P-CBI into Acquire mode: 1. With the keypad connected to AC power, press and hold any two buttons for approximately 10 seconds until the bottom LED blinks, and then immediately release both buttons. 2. Press and hold the top-left button for at least five seconds until the top LED blinks, and then immediately release the button. Improper wireless ID used. Verify that the keypad’s wireless ID matches the wireless ID in the software program. Keypad is not receiving power. Check circuit breaker. Check AC connection. Keypad is not communicating with the P-MNETGW. Repeat the acquire procedures given in section 6. P-CBI is not acquired by gateway. Acquire the keypad to the wireless network. You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Future Updates As Crestron improves functions, adds new features and extends the capabilities of the P-CBI, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column. Turns on Device communicating with P-MNETGW and control system program Blinks one time Device acquired but not communicating with network Device not joined to network Stays off 888.273.7876 CORRECTIVE ACTION If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. The keypad enters the Acquire mode. The top-left LED will blink until the device is acquired. When the device is acquired, the top-left LED will stop blinking and the second-to-bottom-left LED will light. 3. Press the top-left button to exit the Acquire mode. To check the communication status of the P-CBI, perform step 1. The second-to-bottom left LED will indicate communication status as described below. LED COMMUNICATION STATUS www.crestron.com/prodigy POSSIBLE CAUSE(S) Further Inquiries NOTE: Holding the button for more than five seconds may exit the Acquire mode. ©2010 Specifications subject to change without notice. Problem Solving 201.767.3400 All brand names, product names, and trademarks are the property of their respective owners. P-CBI Screws 4-40X1/4” 1