P-CBI-WIRED quickstart guide Prodigy® Wired Keypad 1 1Introduction The Prodigy® P-CBI-WIRED is an elegant yet robust in-wall keypad providing simple direct control of lighting, audio source selection and volume. Whether installed in a retrofit or new construction, the P-CBI-WIRED provides a low-cost interface solution, bringing the benefits of whole house audio distribution to any budget. 2 Application The following diagram illustrates a P-CBI-WIRED in a system with other Prodigy devices. 3 Assembly The P-CBI-WIRED is supplied partially assembled along with several items as listed in the following table. USE ITEM 1. Make sure the light masks are correctly positioned. The light masks will not fall out of their locations, but can easily be removed and/or relocated as necessary. 2. Attach the button strips to the housing assembly according to the way the unit is programmed. The button strips are held in place by three mounting posts. QTY 1 Rear housing with switch circuitry and light masks attached Body of P-CBI-WIRED Bezel Assembly Holds button caps in position on rear housing 1 Screws, steel, flat Phillips head, 4B x 3/4” Attach the mounting plate to the electrical box 2 Two-button cap strip Provides two large-size buttons 2 Three-button cap strip Provides three medium-size buttons 2 Six-button cap strip Provides six small-size buttons 2 Mounting plate Mounts to electrical box and provides mounting point for P-CBI-WIRED 1 Screws, steel, Phillips, pan head, 04-40 x 1/4” Attach the assembled keypad to the mounting plate 4 Assembly Light Masks Button Strip Mounting Posts 3-Button Strip NOTE: The mounting plate can be attached as shown, or can be rotated 90° if necessary to accommodate the orientation of the electrical box. www.crestron.com/prodigy 888.273.7876 201.767.3400 All brand names, product names, and trademarks are the property of their respective owners. Mounting Plate Screws 4B X 3/4” P-CBI-WIRED UK-Style Electrical Box When using two- or three-button cap strips, remove the extra light masks. Use one light mask for two-button strips, two masks for three-button strips, and five masks for six-button strips. (Retain the extra light masks in case the keypad is reprogrammed for a different configuration.) Refer to the illustration in the following column. ©2010 Specifications subject to change without notice. 6-Button Strip 3. If the button strips need to be changed or replaced, insert a flat blade screwdriver into the notches provided and carefully pry the button strip up and off the mounting posts. 4. Using the Phillips screwdriver, attach the mounting plate to the electrical box as shown in the illustration below. Light masks are used to reduce the backlight intensity between the buttons. The housing assembly is shipped with light masks in place for two six-button cap strips. For Regulatory Compliance information, refer to the latest version of Doc. 7075. QUICKSTART DOC. 7074A (2028709) 07.10 Small Flatblade Screwdriver Notch The following items are required for assembly and installation: • Phillips screwdriver (not supplied) • Flat blade screwdriver (not supplied) 1 Removal P-CBI-WIRED quickstart guide Prodigy® Wired Keypad 1 1 6 Configuration 4 1 1 4 Hardware Hookup Use the following procedure to connect the keypad to the Prodigy system. 1. Turn control network power OFF. 2. Connect the control network cable to the keypad’s NET port as shown in the following diagram. 1 7 Troubleshooting Use the Prodigy Composer software to configure your Prodigy system (refer to the online help for detailed information). The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. NOTE: The Prodigy Composer software is available for download from www.crestron.com/prodigycomposer. TROUBLE The keypad does not function. To configure the P-CBI-WIRED: Red White Blue Black 51 4 2. In the Processor step of the wizard, connect to the PMCI2. The wizard automatically detects the PMCI2. a. In the list of devices, click the P-CBI-WIRED device to be configured. Screws 4-40X1/4” • Click Touch Device. All LEDs on the keypad blink. Touch any button on the keypad. The LEDs stop blinking, and the correct serial number is automatically configured. 888.273.7876 Improper Net ID is used. Verify that the Net ID matches the Net ID in the software program. Check the Crestron website periodically for manual update availability and its relevance. Updates are identified as an “Addendum” in the Download column. Bezel www.crestron.com/prodigy Verify that the cable connected to the NET port is secure. As Crestron improves functions, adds new features and extends the capabilities of the P-CBI-WIRED, additional information may be made available as manual updates. These updates are solely electronic and serve as intermediary supplements prior to the release of a complete technical documentation revision. After serial numbers are configured, the Net ID of each P-CBI-WIRED in the system is automatically configured in the System Setup step of the wizard. ©2010 Specifications subject to change without notice. A loose connection exists in the network. Future Updates 2. Attach the bezel by putting it in position over the button caps and snapping it in place. 3. Turn control network power ON. For Regulatory Compliance information, refer to the latest version of Doc. 7075. QUICKSTART DOC. 7074A (2028709) 07.10 Verify that the cable plugged into the NET port is secure. You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to ask questions about Crestron products. First-time users will need to establish a user account to fully benefit from all available features. Keypad Assembly 2 The keypad is not receiving power, or is receiving insufficient power. If you cannot locate specific information or have questions after reviewing this guide, please take advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON [1-888-273-7876]. Select the serial number from the drop-down list, and then click Assign Serial. The serial number selected must match the serial number labeled on the side of the keypad. 4. Repeat step 3 above for each keypad in the system. Mounting Plate CORRECTIVE ACTION 201.767.3400 All brand names, product names, and trademarks are the property of their respective owners. P-CBI-WIRED CAUTION: Excess wire pinched between the keypad and electrical box could cause a short circuit. Make sure that all excess wire is completely inside the electrical box and not between the box and the keypad. • The buttons and feedback LEDs do not work (backlighting works in low light). POSSIBLE CAUSE(S) Further Inquiries b. Do either of the following: Installation Use the following procedure to install the keypad in an electrical box. 1. Push the wires into the electrical box and use the Phillips screwdriver to attach the keypad assembly to the mounting plate as shown in the following illustration. ! 1. Launch the Prodigy Network Setup Wizard, which is included within Prodigy Composer. 3. In the Device Matching step of the wizard, configure the serial number of the P-CBI-WIRED as follows: NOTE: Do not connect the INPUT port. Problem Solving