LED Magnum 8” Downlight Installation instructions for MAG8 Series WARNING: These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with these instructions, and with current electrical codes and/or the current National Electric Code (NEC). This light module is intended to be installed only by qualified personnel. WARNING: To avoid electric shock, disconnect power at source prior to installation. Save these instructions. Alteration of the fixture will void the warranty. Do not make or alter any open holes in a wiring enclosure, nor in any electrical components during kit installation! WARNING: Risk of fire or electric shock. Kit installation requires knowledge of recessed lighting luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. SUITABLE FOR USE IN DRY AND DAMP LOCATIONS; AND TYPE IC LOCATIONS. Do not use these products in areas where elevated ambient temperatures exist. This fixture is suitable for installation where ambient temperatures do not exceed 104˚F (40˚C) during anticipated hours of fixture operation. This fixture is airtight certified. Not for use in dimming circuits. WARNING: Risk of fire or electric shock. The electrical rating of this product is 120-277V AC. The installer must determine that the supply is within the range of 120-277V AC at the luminaire before installation. WARNING: To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. This product cannot be disassembled. The LEDs are not replaceable. If the LEDs become damaged, the fixture should be disconnected and recycled. Failure to do so may result in electric shock, and become a fire hazard. FUTURE LAMP REPLACEMENT: Model MAG8-XX-XX (8” MAGNUM LED Downlight) is available from American Lighting, Inc. Contact 800-880-1180 or visit www.americanlighting.com to find a local distributor. NEW CONSTRUCTION/REMODEL/RETROFIT: No rough-in can needed! Best practices include use of a laser to mark fixture locations on floor for finish electrical; and removing any existing housings through cut-out hole or through plenum as needed. CAUTION: Always make sure power to the fixture is disconnected before beginning of removal of existing lamp and/or trim, or beginning installation. Failure to do so can cause electric shock, which can result in injury or death. INSTALLATION 1. Using the cut-out template supplied with the fixture, mark and cut a 8.07 inch round hole in the ceiling where the fixture is to be mounted. See Figure 1. Four knockouts (two on opposing sides) for use with 1/2” conduit and 3/8” clamp connectors (not included with fixture). Figure 1 Junction Box Cover 2.67 in 5.38 in 7.74 in 9.05 in Figure 2 Knockouts are located on two sides of junction box 8.07 in Cut-out template = 8.07” (205mm) diameter 2. Remove attached junction box cover and set aside. Punch out whichever knockout is best suited for connection to supply wires. Knockouts are located on the sides of the junction box. See Figures 1 and 2. (CONTINUED ON REVERSE) Denver, CO 80231 • www.americanlighting.com © 2014 American Lighting, Inc. RV1411 Page 1 of 2 LED Magnum 8” Downlight Installation instructions for MAG8 Series INSTALLATION (CONTINUED FROM REVERSE) 3. Install 3/4” cable connnector to this open knockout and connect fixture wires following National Electric Code and/or local building code requirements. Use minimum 18AWG solid copper wires. AC supply should be protected by circuit breaker or fuse. 4. Attach line voltage AC supply wires to fixture lead wires: Black to Black/Hot, White to White/Neutral and Yellow/Green (Ground) to Green or bare wire inside the fixture. Secure each connection using UL Listed wire connectors. If your system has no ground wire, consult a qualified electrician before proceeding with the installation. Note: Electric shock, overheating, low or no light output and shortened fixture life can result if proper grounding is not done. See Figure 3. 5. Connect support cable kit to both sides of junction box housing using slots in junction box side straps. See Figure 4. 6. Tie off cable kit to a plenum rated support of the building. Alternatively, run appropriately sized lengths of empty conduit through side straps in lieu of tying off. 7. Pull spring brackets upward (see Figure 6), then place the Downlight into the ceiling (see Figure 7). Spring brackets will hold Downlight securely in place. 5- YEAR LIMITED PRODUCT WARRANTY This product is warranted to be free from defects in material and workmanship for a period of five years from the date of purchase. Products that prove to be defective during this period will be either repaired (i.e. replacement of defective electronics, defective parts of the fixture housing, lens, wiring, switching or lamp sockets; excluding the lamp) or replaced, at the discretion of American Lighting, Inc. Claims for defective products must be submitted to the retail location from which the product was purchased within the warranty period. Upon submission of proper return claim documentation and product to American Lighting, Inc by the retailer, American Lighting, Inc reserves the right to inspect the product for misuse or abuse. Claims for indirect or consequential damages or for product that, in American Lighting Inc's opinion has been misused will be denied. This is a warranty of product reliability only and not a warranty of merchantability or fitness for a particular purpose. American Lighting, Inc shall have no liability whatsoever in any event for payment of incidental or consequential damages, including, without limitations, installation costs and damages for personal injury and property. These products may represent a possible shock or fire hazard if improperly installed or altered in any way. This warranty applies only to product that has been properly installed in accordance with instruction sheet and current local codes and/or the National Electrical Code. Warranty does not apply to any product that has been improperly installed or in situations where components have been altered in any way. Figure 3 Figure 4 Cable kit Side strap with slot Figure 5 Tie off to plenum rated building support Cable Kit Ceiling Figure 6 Figure 7 For questions / comments, technical assistance or repair parts – Please call toll free at: 1-800-285-8051 (M-F 8am – 5pm, MST) Ceiling © 2014 American Lighting, Inc. Denver, CO 80231 • www.americanlighting.com RV1411 Page 2 of 2