Addendum MAN-0156, Rev 2 March 2016 FC Wireless Enabled Feature Addendum 1.1 Introduction The products supplied have an enhanced firmware version that makes them compatible for communication with the Smart Wireless THUM Adapter. As such, the certifications outlined in the product’s instruction manual have been changed as per the certifications shown on this document and the product label. The products affected by this change are outlined in the table below: Model Number Description M21-AH-x-FC Millennium II transmitter, analog/HART outputs, wireless capable M21-AHR-x-FC Millennium II transmitter, analog/HART/relay outputs, wireless capable M2B-AH-x-FC Millennium II Basic transmitter, analog/HART outputs, wireless capable SC310x-100-ASSY-FC Millennium II catalytic bead combustible sensor for use with Millennium II wireless capable transmitters SC311x-100-ASSY-FC Millennium II infrared combustible sensor for use with Millennium II wireless capable transmitters TX-M21-AH-FC Replacement Millennium II transmitter board for M21-AH-x-FC TX-M21-AHR-FC Replacement Millennium II transmitter board for M21-AHR-x-FC TX-M2B-AH-FC Replacement Millennium II transmitter board for M2B-AH-x-FC 1.2 Millennium II transmitters (M21-AH & M21-AHR) 1.2.1 North America Class 1 Division 1 Groups BCD T5 Class I, Zone 1 AEx/Ex d IIB+ H2 T5 -40 °C ≤ Ta + 75 °C NEMA Type 4X/IP 67 CSA C22.2 No. 152:2006 1.2.2 IECEx (aluminum) Ex d IIB+H2 T5 Gb -40 °C ≤ Ta + 85 °C IP66 IECEx DNV 12.0014 1 Addendum March 2016 1.2.3 MAN-0156, Rev 2 IECEx (stainless) Ex d IIB+H2 T5 Gb -40 °C ≤ Ta + 85 °C) IP67 IECEx FMG 12.0006X Special conditions for safe use: • Consult the manufacturer if dimensional information on the flameproof joints is necessary. 1.3 Millennium II Basic transmitters (M2B-AH) 1.3.1 North America Class 1 Division 1 Groups BCD T5 Class I, Zone 1 AEx/Ex d IIB+ H2 T5 -40 °C ≤ Ta + 75 °C NEMA Type 4X/IP 64 CSA C22.2 No. 152:2006 1.3.2 IECEx Ex d IIB+H2 T5 Gb -55 °C ≤ Ta + 85 °C IP67 IEC 60079-0:2011/IEC60079-1:2007 IECEx FMG 14.0010X Special conditions for safe use: • Consult the manufacturer if dimensional information on the flameproof joints is necessary. • Follow the manufacturer’s instructions to reduce the potential of an electrostatic charging hazard. 1.4 Millennium II catalytic bead combustible sensors (SC310) 1.4.1 North America Class 1 Division 1 Groups BCD T5 Class I, Zone 1 AEx/Ex d IIB+ H2 T5 -40 °C ≤ Ta + 75 °C NEMA Type 4X/IP 64 CSA C22.2 No. 152:2006 2 Addendum MAN-0156, Rev 2 1.4.2 March 2016 IECEx Ex d IIB+H2 T5 Gb -40 °C ≤ Ta + 75 °C IP64 IECEx FMG 12.0007X Special conditions for safe use: • Consult the manufacturer if dimensional information on the flameproof joints is necessary. • The flying leads of the Millennium II sensor shall be suitably protected against mechanical damage and terminated within a terminal or junction facility suitable for the conditions of use. 1.5 Millennium II infrared combustible sensors (SC311) 1.5.1 North America Class 1 Division 1 Groups BCD T5 Class I, Zone 1 AEx/Ex d IIB+ H2 T5 -40 °C ≤ Ta + 75 °C NEMA Type 4X/IP 64 CSA C22.2 No. 152:2006 1.5.2 IECEx Ex d IIB+H2 T5 Gb -40 °C ≤ Ta + 75 °C IP64 IECEx FMG 12.0007X Special conditions for safe use: • Consult the manufacturer if dimensional information on the flameproof joints is necessary. • The flying leads of the Millennium II sensor shall be suitably protected against mechanical damage and terminated within a terminal or junction facility suitable for the conditions of use. 3 Addendum March 2016 MAN-0156, Rev 2 EmersonProcess.com/FlameGasDetection Americas Emerson Process Management 6021 Innovation Blvd. Shakopee, MN 55379 T +1 866 347 3427 F +1 952 949 7001 Safety.CSC@Emerson.com Europe Emerson Process Management AG Neuhofstrasse 19a P.O. Box 1046 CH-6340 Baar Switzerland T + 41 (0) 41 768 6111 F + 41 (0) 41 768 6300 Safety.CSC@Emerson.com Middle East & Africa Emerson Process Management Emerson FZE Jebel Ali Free Zone Dubai, UAE P.O. Box 17033 T + 971 4 811 8100 F + 971 4 886 5465 Safety.CSC@Emerson.com Asia Pacific Emerson Process Management 1 Pandan Crescent Singapore 128461 Singapore T + 65 777 8211 F + 65 777 0947 Safety.CSC@Emerson.com 4 AnalyticExpert.com Twitter.com/Rosemount_News Facebook.com/Rosemount Youtube.com/user/RosemountAnalytical ©2016 Emerson Process Management. All rights reserved. Emerson Process Management, Rosemount Analytical, and Net Safety are marks of Emerson Process Management group of companies. All other marks are the property of their respective owners. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.