8-OW1IP Catalog Number Project Name Type T8 /T5 8’ VAPOR TIGHT, IP65 WET LOCATION LUMINAIRE (1 OR 2 LAMP 8’) OR (2 OR 4 LAMP 8’ TANDEM) OW1IP S H I P P I N G AVA I L A B L E APPLICATION: The OWIP series is suitable for wet location areas. Common applications include parking garages, schools, industrial facilities, and stairways. PRODUCT FEATURES: • Suitable for suspension by Chain, cable or pendant. Can also be surface mounted. All required hardware and mounting brackets are included. Suspension systems are not included. Chain or stainless steel cable are available as options . • Integral Molded Latch retention pockets securely locks in polycarbonate latches. Stainless steel latches available upon request. STRUCTURALLY RIGID FIBERGLASS BODY • Fiberglass is reinforced polyester and self-extinguishing (ASTM D63574). This type of construction does not allow the body to flex during handling and installation. GASKETED DIFFUSER RETENTION SLOT • The gasketed inverted U-slot provides a positive continuous seal between body and diffuser. • Continuous poured gasket completely fills channel for maximum seal integrity HIGH IMPACT ACRYLIC/DR DIFFUSER • Internal crepe pattern allows a smooth exterior surface for ease of cleaning. • The diffuser flange fits snugly into the gasketed retention slot forming a continuous seal. • Optional 95% reflective silver reflector. (See Gear tray on page 112) • CEE qualified ballast found standard on most fixture options. LISTING • UL/ C-UL listed to US and Canadian standards. 65 4-7/8” 6-5/8” • IP65 Rating. (See accessories on page 112) 98” WARRANTY - Guaranteed for one year against mechanical defects. T8/T5 Ordering Information EXAMPLE: 8-OW1IP-2-32-T8 OW1IP FIXTURE SIZE SERIES #LAMPS/LAMP TYPE 8 - 8’ OW1IPOracle Wet Location Vapor Tight 1-59-T8 (1 lamp/59W/T8) 2-59-T8 (2 lamps/59W/T8) 2-32-T8 (2 lamps/32W/T8) 4-32-T8 (4 lamps/32W/T8) 6-32-T8 (6 lamps/32W/T8) 2-28-T5 (2 lamps/28W/T5) 4-28-T5 (4 lamps/28W/T5) 6-28-T5 (6 lamps/28W/T5) 2-54-T5HO (2 lamps/54W/T5HO) 4-54-T5HO (4 lamps/54W/T5HO) 6-54-T5HO (6 lamps/54W/T5HO) VOLTAGE2 # OF BALLAST BALLAST FACTOR LAMPS INSTALLED (Blank)- Normal BF HBF- High BF LBF- Low BF (Blank) - N o lamps L30K - 3000K L35K - 3500K L41K - 4100K L50K - 5000K (Blank) - MVOLT (120/277) (Blank) -1 Ballast 2 -2 Ballasts 120 277 347 480 EMERGENCY BATTERY PACK OPTIONS (L. = LUMENS) EMG-T8-BX-450 DESCRIPTION Up to 450 L. for T8 or BX EMG-T8-BX-600 Up to 600 L. for T8 or BX EMG-T8-BX-700 Up to 700 L. for T8 or BX BALLAST CONFIGURATION & CODE EMG-T8-BX-1400 Up to 1400 L. for T8 or BX 32W/T8 59W/T8 28W/T5 DESCRIPTION EMG-T5-T5HO-700 Up to 700 L. for T5 or T5HO (Blank) EPS ADV-7 ADV-101 (Blank) EPS - (Blank)1 - (Blank) ADV-71 ADV-101 Electronic Instant Start Electronic Program Start Advance Mark-72 Advance Mark-102 EMG-T5-T5HO-1300 Up to 1300 L. for T5 or T5HO EMG-T8-BX-T5-T5HO-3200 Up to 3200 L. for T8, BX, T5 or T5HO EMG-SD-T8-BX-T5-T5HO-1400 Self-Diagnostic 1400 L. for T8, BX, T5 or T5HO EMG-ICE-T8-BX-T5-T5HO-1400 ICE Pack 1400 L. for T8, BX, T5 or T5HO - - ADV-OPT - ADV-ESS1 - - - ADV-ROVR - - ADV-ROVR LUT-EHD1 - LUT-EHD1 LUT-EHD1 54W/T5HO Advance Optanium2 1 ORDER CODE Advance Essential2 WIRING OPTIONS Advance Rover PCSB120 - 10’ Nema 5-15R 120V Straight Blade Plug CH - Heavy Duty Chain Lutron Ecosystem H-Series2 PCSB277 - 10’ Nema 7-15R 277V Straight Blade Plug MS - Motion Sensor 2 OTHER OPTIONS LUT-2W1 - - - Lutron Tu-Wire2 PCTL120 - 10’ Nema L5-15R 120V Twist Lock Plug MSPH - Motion Sensor with Photocell LUT-EC51 - LUT-EC51 - Lutron Ecosystem2 PCTL277 - 10’ Nema L7-15R 277V Twist Lock Plug WLMS - Wet Location Motion Sensor LUT-EC31 - LUT-EC31 LUT-EC31 Lutron Eco-102 - 10’ 120V IP Rated Twist lock Plug LUT-TVE 1 - - - IPTL120 Lutron Tve - LUT-H3D1 LUT-H3D1 Lutron Hi-Lume 3D2 IPTL277 - 10’ 277V IP Rated Twist lock Plug LUT-H3D1 - - - LUT-ECD1 Lutron Ecosystem (347V Only)2 2 1- Requires 2 Ballasts for 4 lamps. 2- Voltage must be specified for dimming ballast. Wet Location 8’ Vapor Tight Fluorescent 8 OW1IP SO1 - 10’ 120V/277V SO Cord SO2 - 10’ 480V SO Cord (Consult Factory for 208V, 248V, 347V and 480V wiring) GSS - Gripple Suspension System VH - V Hook SSL - Stainless Steel Latches OW1IPSR - Specular Reflector SSLTP - Stain Steel Latches with Tamper Proof PCLTP - Polycarbonate Latches with Tamper Proof Screws USA - Made in America Compliance WWW. OR AC L E L I G H T I N G .C O M • TEL: 1-877-375-5555 • FA X : 1 - 8 7 7 - 3 7 5 - 3 3 3 3 109 Wet Location Enclosed Gasketed 65,66,67 WET LOCATION Wet rated certification (IP 65 /67) is often required in outdoor and indoor lighting applications, Elites vapor tight and hydro beam series of lighting fixtures meet the high demands of this requirement and more, we also meet ratings for NSF splash zone 2, hose down – 1300 PSI and Nema – 4X. FOOD PROCESSING FACILITIES SAFETY Fully enclosed and gasketed linear fluorescent luminaries are an excellent product choice for all food processing/food handling environments. Elite offers several fixture styles that meet the need of this industry. Our fixtures and IP6S and/ or IP67 rated for wet location and are approved/ listed by UL (Underwriters Laboratory) NSF (National Sanitation Foundation) International and the Canadian Standards Association Dept. of Agriculture. Food Processing Meat Packing Bottling Centers Cheese Factories Produce Centers Fish Packing Bakeries 94 UP TO 88% EFFICIENCY Protection from broken lamps is always a necessity in and around workplace environments where accidental contact with fixtures is a risk. Also, recreational areas such as, gymnasiums, sports facilities, etc. are vulnerable to the possibility of impact and possible breakage. High-impact polycarbonate plastics are used on all of the Elite (our) enclosed housing fixtures to ensure that safety is a must. 95 A- The first IP Character represents the protection against hazardous parts and solid foreign objects. B- The second IP Character represents the protection against water ingress. IP First Character 1 3 3R 3S 4 4X 5 6 6P 12 IP Second Character 12K 13 IP0_ IP_0 IP1_ IP2_ IP3_ IP4_ IP5_ IP6_ IP_1 IP_2 IP_3 IP_4 IP_5 IP_6 IP_7 IP_8 A 96 2 B A B A B A B A B A B A WWW.ORACLELIGHTING . COM B A B A B A B A • TEL: 1- 8 7 7 - 3 7 5 - 5 5 5 5 B A B A B • FA X : 1 - 8 7 7 - 3 7 5 - 3333 A Brief Comparison of NEMA 250 and IEC 60529 WHAT IS AN “IP CODE?” The IP Code is designation that indicates the level, or amount, of the protection. The IP Code designation consists of the letters IP (International Protection) followed by two numerals. WHAT DOES THE FIRST NUMERAL OF AN IP CODE INDICATE? The first characteristic numeral indicates the degree of protection provided by the enclosure with respect to persons having access to hazardous parts and with respect to solid foreign objects entering the enclosure. The first number specifies the following as described in Table 1. TABLE 1 First Characteristic Numeral With Respect to Persons With Respect to Solid Foreign Objects 0 Non-protected. Non-protected. 1 Protected against access to hazardous with the back of the hand. Protected against solid foreign objects > _ 50 mm diameter. 2 Protected against access to hazardous parts with a finger. _ Protected against solid foreign objects > 12.5 mm diameter. 3 Protected against access to hazardous parts with a tool. Protected against solid foreign objects > _ 2.5 mm diameter. 4 Protected against access to hazardous parts with a wire. _ Protected against solid foreign objects > 1.0 mm diameter. 5 Protected against access to hazardous parts with a wire. Dust-protected (Dust shall not penetrate in quantity to interfere with satisfactory operation of the apparatus or to impair safety). 6 Protected against access to hazardous parts with a wire. Dust-tight (No ingress of dust). WHAT DOES THE SECOND NUMERAL OF AN IP CODE INDICATE? The second characteristic numeral indicates the degree of protection provided by the enclosure with respect to the harmful ingress of water. The second number specifies the following as described in Table 2. TABLE 2 Second Characteristic Numeral With respect to the Harmful Ingress of Water 0 Non-protected. 1 Protected against vertically falling water drops. 2 Protected against vertically falling water drops when enclosure titled Up to 150. 3 Protected against spraying water. 4 Protected against splashing water. 5 Protected against water jets. 6 Protected against powerful water jets. 7 Protected against the effects of temporary immersion in water. 8 Protected against the effects of continuous immersion in water. WWW. ORACLELIGHTING . COM • TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5 • FA X : 1 - 8 7 7 - 3 7 5 - 3 3 3 3 97 ACCESSORIES SECTION OW1IP & OW2IP INFORMATION NEW Optional 95% Reflective Specular Reflector Boosts Gasketed Enclosure Reflectivity, Efficiency Now Oracle is pleased to announce a new 95% reflective specular reflector to increase the performance of our OW1IP & OW2IP gasketed enclosure line. Reflector Feature: :: .020 Nominal Thickness :: 95% Reflectivity :: Provided With A Protective Film For Easy Handling :: Surface Is Absolutely Free Of Iridescent Colors :: Offers Outstanding UV Stability Benefits :: Improved Performance :: Increased Lumen Levels In The O-90 Zone :: Available For Both T5 And T8 :: Batwing Distribution Provides Uniform Horizontal Illumination :: Approvals and/or Listings Underwriters Laboratories(UL) NSF International, U.S. Department of Agriculture, Canadian Standards Association :: Increased Spacing Criteria. Wider Light Distribution Can Require Fewer Fixtures T8/T5 OWIP Gasketed Enclosure Fixture Performance “Before & After“ REFLECTOR Accessories- Gear Tray EFFICIENCY DESIGN LUMENS DELIVERED LUMENS input watt EFFICACY LUMENS/WATT Standard 75 5,600 4,200 60 70 Specular 95% 82 5,600 4,592 60 77 Reflective IP65 Rating Tape Gasket Conventional Poured Gasket New & Improved Poured Gasket Protection against ingress of dust and low pressure jetting water as per IEC 60529 standard. Component requirements to achieve rating: :: All 4 foot housings that contain 6 latch pockets :: All 8 foot housings that contain 10 latch pockets :: All 4 foot and 8 foot diffuser styles :: All conduit entries must be properly sealed IP67 Rating Protection against ingress of dust and temporary immersion in water as per IEC 60529 standard. Component requirements to achieve rating: :: All 4 foot housings that contain 8 latch pockets :: All 8 foot housings that contain 14 latch pockets :: All 4 foot and 8 foot diffuser styles :: All conduit entries must be properly sealed 112 WWW.ORACLELIGHTING . COM • TEL: 1 - 8 7 7 - 3 7 5 - 5 5 5 5 • FA X : 1 - 8 7 7 - 3 7 5 - 3333 COMPONENTS of OW1IP & OW2IP SERIES T8/T5 Standard Assembly consists of fiberglass housing with poured, continuous gasketing, latches, sealing end plugs and high impact acrylic diffuser. OWIP Components OWIP Series Brackets for OW1IP & OW2IP Oracle Lighting offers a new bracket system for the OW1IP & OW2IP new bracket that is revolutionary in its simplicity. BENEFITS :: Easiest Installation Ever -Bracket installs first, then fixture snaps securely into place :: Corrosion Resistant Stainless Steel :: Mounting method does not require stud in fixture MOUNTING BRACKET FIXTURE INSTALLATION Install Mounting Bracket :: Screw Hardware by Others :: T-Bar Mounting Hardware by Others WWW. ORACLELIGHTING .COM Install One Side of Housing into Bracket Rotate Up and Snap Other Side of Housing into Bracket Install diffuser once unit is securely installed with bracket. • TEL : 1- 8 7 7 - 3 7 5 - 5 5 5 5 • FAX : 1 - 8 7 7 - 3 7 5 - 3 3 3 3 113