XEP - Columbia Lighting

advertisement
XEP
Parking Garage Vaportight / 2-Lamp T5 or T8
PROJECT INFORMATION
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Type
Catalog No.
Date
CONSTRUCTION
Parking Garage Vaportight Industrial
Available in 4' or 8' lengths
T8, T5, or T5HO fluorescent
IP65 and IP67 standard
Fiberglass housing with F1 weatherability rating, standard
Smooth housing for ease of cleaning
Internal reflector directs light into parking bays
Gasket is non-porous to ensure seal
Impact modified acrylic lens
Lens selections include optically clear or frost
Lens firmly secured with tamper resistance ready
polycarbonate latches
Stainless steel latching optional
Removable gear tray electrical access
Includes surface mounting brackets
CSA c/US labeled, built to UL 1598, UL924 as appropriate
Available with exclusive wiHUBB technology preinstalled
ORDERING INFORMATION
XEP
Housing is formed from UL 5VA fiberglass. F1
weatherability rating, suitable for indoor or
outdoor use with respect to exposure to UV light.
Pour-in-place non-porous gasketing assures
seal. Fluorescent lamp sockets and ballast affixed
to removable gear tray. Specialized reflector
optically designed to maximize light distribution
for indoor parking applications. 14 Latches per 8',
8 per 4'. Latches are provided tamper resistance
ready, tamper resistant screws optional. Latches
are standard polycarbonate, optional in stainless
steel. Captive latches (optional) secure to housing
using single center hook. Standard latches are
compression fit. Knockouts are provided for
electrical access and mounting.
SHIELDING
Deep acrylic lens impact modified to 100% DR
equivalency. Optically clear lens standard, frost
optional.
(See page 2 for Product Availability Data and Sensor Kits)
2
–
MODEL
XEP Parking
Garage
Vaportight
Industrial
Project Name
–
NO. OF LAMPS IN
CROSS SECTION
4 4'
8 8'
ELECTRICAL
Standard class “P”, thermally protected,
auto-resetting HPF ballast, sound rated A. CEE
NEMA Premium compliant. All ballast leads extend
a minimum of 6" through access location. NEC/CEC
compliant ballast disconnect is standard.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate CSA c/US labels. Ingress protection
IP67 standard. National Sanitation Foundation
(NSF) certified. Wet location labeling is standard.
Emergency-equipped fixtures built to UL 924.
EXAMPLE XEP4-254-DCA-EPU
–
–
OPTIONS
BALLAST
2 Two
SIZE
FINISH
White painted parts are treated with a five-stage
phosphate bonding process and finished with high
reflectance baked enamel.
LAMP TYPE
28 4', T5 Standard: 28 Watt
32 4', T8: 32, 30, 28, or 25 Watt
54 4', T5HO: 54 Watt
E Electronic, T8, Instant Start
(Standard)
4E 4-Lamp Electronic, Instant Start (T8)
EP Electronic, Programmed Start
4EP 4-Lamp Electronic, Programmed
Start (T8 only)
ESD Electronic Step Dimming for 2-Lamp
4' only1
ED Electronic Dimming2
4ED (1) 4-Lamp Electronic Dimming2
LENS TYPE
DCA Deep Clear Acrylic
DFA Deep Frosted Acrylic
Can be converted to fixed output by tying hot leads together.
Not compatible with T8 25, 28, or 30 Watt energy-saving lamps.
Captive latches (optional) secure to housing using single center hook. Standard latches are compression fit.
4
In-Fixture Module Antenna is mounted in gear tray beneath lens.
5
HT option not available for T5HO.
6
Paint After Fabrication of gear tray back pan; parking reflector remains specular.
7
Requires 3⁄8" OD threaded rod by others.
8
2 required for 8' fixture
1
2
3
ACCESSORIES
(ORDER SEPARATELY)
XEHC Chain Hanger Kit
(Includes 14" Chain)
XE45MB 45º Mounting Bracket8
XE45MBSS 45º Stainless Steel
Mounting Bracket
Not all configurations are compatible; for questions contact Hubbell Lighting representative.
Page 1/3 Rev. 03/21/16
© 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
EL
EL141
EL5
EL5H
VOLTAGE
GLR
U 120V-277V
GMF
120 120V
TP
277 277V
CL
347 347V
SSL
480 480V
FO835
FO841
BALLAST
FO850
FACTOR
F5841
Blank Standard
F5850
LW Low Watt
F3C8W
HL 1.18 BF High
Lumen 4' T8 F3C15W
SWH
DWH
WIH
HT
XEDPM
350-450 Lumen T8 Battery Pack
900-1400 Lumen T8 Battery Pack
390-700 Lumen T5, T5HO Battery Pack
600-1325 Lumen T5, T5HO Battery Pack
Fast Blow Fuse
Slow Blow Fuse
Tamper Proof Screws
Captive Latches3
Stainless Steel Latches
T8 Lamp Installed, 82 CRI, 3500K
T8 Lamp Installed, 82 CRI, 4100K
T8 Lamp Installed, 82 CRI, 5000K
T5 Lamp Installed, 82 CRI, 4100K
T5 Lamp Installed, 82 CRI, 5000K
3 Wire 8' Wet Cord
3 Wire 15' Wet Cord
Single Wet Hub 1⁄2" NPT Hub
Dual Wet Hub 1⁄2" NPT Hub
wiHUBB Enabled4
Elevated Ambient Rating 40°C 5
Dual Pendant Brackets
(pendant by others)7
PAF Paint After Fabrication6
EXTREME ENVIRONMENT / XEP
XEP
Parking Garage Vaportight / 2-Lamp T5 or T8
PRODUCT AVAILABILITY DATA
PRODUCT AVAILABILITY
Size
4'
8'
# of Lamps in
Cross Section
2
2
# of Lamps in
Fixture
2
4
SENSOR KITS (Order Separately)
Lamp Type Width
28,32, 54
28,32, 54
67⁄9"
67⁄9"
All sensor kits include Occupancy & Daylight.
Daylight activation requires setting of dip-switches on site.
Catalog #
# Relays Lens Type Voltage Wet Label
OS1360WLK
1
360°
120/277/347
Yes
120V / OS2360WLK
2
360°
120/277/347
Yes
277V /
1
Aisle
120/277/347
Yes
347V OS1AWLK
OS2AWLK
2
Aisle
120/277/347
Yes
OS1360480WLK
1
360°
480V
Yes
1
Aisle
480V
Yes
208V / OS1A480WLK
480V OS1360208WLK
1
360°
208V
Yes
OS1A208WLK
1
Aisle
208V
Yes
Height
DCA, DFA
55⁄8"
55⁄8"
Length
512⁄3"
100"
PHOTOMETRIC DATA
LUMINAIRE DATA
Luminaire
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in Feet
Test 7759 Test Date 10/9/13
INDOOR CANDELA PLOT
XEP4-232-DCA-EU
XEP Enclosed and Gasketed Parking,
Industrial 6" X 51"
2-LAMP T-8 SURFACE-MOUNT WITH
DEEP CLEAR ACRYLIC LENS AND
SPECULAR REFLECTOR
ICN-2P32-N
0.88
F32T8
2850
56
Surface
0º = 90 90º = 90
0º = 1.25 90º = 1.21
Length: 4.25
Width: 0.54
Height: 0.27
180
165
ENERGY DATA
150
Total Luminaire Efficiency
74.5%
67
120
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
105
ZONAL LUMEN SUMMARY
135
1100
Noncompliant
$3.58 based on
3000 hrs. and
$0.08 per KWH
550
Zone
0-30
90
75
0-40
0-60
0-90
0-180
Lumens % Lamp % Fixt.
771
1252
2383
3863
4246
13.5
22.0
41.8
67.8
74.5
18.2
29.5
56.1
91.0
100.0
550
60
1100
0
0.0
15
30
Horiz 0-180
45.0
45
90.0
Page 2/3 Rev. 03/21/16
© 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
EXTREME ENVIRONMENT / XEP
XEP
Parking Garage Vaportight / 2-Lamp T5 or T8
DIMENSIONAL DATA
D
A
C
B
DCA, DCF Lens
PRODUCT NUMBER
XEP
XEP4
XEP8
NOTE:
Size
4'
8'
WIDTH
HEIGHT
DCA, DFA
LATCH
LENGTH
A
67⁄9"
67⁄9"
B
55⁄8"
55⁄8"
C
22⁄5"
22⁄5"
D
512⁄3"
100"
All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 3/3 Rev. 03/21/16
© 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
EXTREME ENVIRONMENT / XEP