SECTION N Locking and Corrosion Resistant Devices INDEX Locking and Corrosion Resistant Devices Index Industrial Specification Grade Locking Devices Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .N2–N4 15 Amp Devices . . . . . . . . . . . . . . . . . . . . . .N5, N6 20 Amp Devices . . . . . . . . . . . . . . . . . . . . .N7–N11 30 Amp Devices . . . . . . . . . . . . . . . . . . . .N12–N16 Wetguard® Devices 15 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N17 20 Amp . . . . . . . . . . . . . . . . . . . . . . . .N17, N18 30 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N19 Corrosion Resistant Devices 15 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N20 20 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N21 30 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N22 50 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N23 Non-NEMA Devices 15 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N24 20 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N24 30 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N25 50 Amp . . . . . . . . . . . . . . . . . . . . . . . . . . . .N25 50 Amp "California Style" . . . . . . . . . . . . . . .N26 Weather Resistant Boots . . . . . . . . . . . . . . . . . .N27 Power Interrupting Devices . . . . . . . . . . . . . . . .N28 Midget Straight Blade and Locking Devices . . . .N29 Combination Locking and Straight Blade Devices . . . . . . . . . . . . . . . . . . .N30 Integrated Inlets and Outlets with Weather Resistant Covers . . . . . . . . . . . . . . . . .N30 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com LOCKING DEVICE FEATURES Industrial Grade Locking Devices LOCKING DEVICES FOR THE ENTIRE SPECTRUM OF INDUSTRIAL APPLICATIONS Leviton’s Industrial Grade Locking Devices are built to provide unparalleled quality and superior performance in the most severe industrial settings. The Locking Devices line represents a broad selection of plugs and connectors, locking receptacles, flanged inlets and outlets, California-style devices, midget locking devices, power interrupting devices, and non-NEMA devices. Leviton combines the best materials available with superior production standards to produce a broad selection of Locking Devices of unmatched flexibility and dependability. Transparent wiring chambers provide a means of visual inspection of conductors and terminals Internal wiring chambers isolate individual conductors to prevent flashover, arcing, and stray strands of wire Color-coded terminal screws External cord clamp utilizes deep triple drive steel screws that are backed out and positioned inside shrouded pockets. External clamp accepts wire mesh grips Cleat on contacts cuts oxidation when plug blades enter contact surfaces Locking Devices Cable gage identifies maximum cord size allowed with strain relief insert One-piece, rivetless, .035" thick brass contacts offer enlarged contact surface areas, improved conductivity, low resistance, low heat and long life • UL 498 Listed • Federal Specification WC-596 Listed • CSA Specification C22.2 No. 42 Certified Ergonomically designed fluted body with radial gripping ridge creates an ideal surface for gripping, turning and pulling Color-coded terminal screws Deep slotted/ Phillips/Robertson steel screws secure wiring module (12-14 in.-lbs) to body Combination #10-32 deep slotted/ Phillips brass screws easily torque to 10-14 in.-lbs. Molded-in strip gage provides correct measurement for proper strip length of conductor NEMA configuration, agency certifications and device rating are molded on front of device to assist with identification Solid brass blades are fitted and held tightly and securely in place Dead front construction prevents accidental contact with internal parts Wiring module keyed to body for easy assembly Speed drive screws for faster assembly LIFETIME N Shrouded pockets in cord clamp prevents slippage of screwdriver blade when tightening clamp screws. Super Tough Nylon resists damage from severe impact, abrasion and chemical attack Terminal identification letters on back cover ensure quick and accurate termination Positive crimp contact plate bundles stranded wire maximizing wire/clamp surface contact Wire clamps move within individual chambers to provide positive clamp lock without cutting wire strands. Captive terminal screws eliminate nuisance dropping and searching for missing screws. Deep-funnelled, large wire wells guide conductors into termination position. learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 2Courtesy of Steven Engineering,To Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com LOCKING DEVICE FEATURES Industrial Grade Locking Devices LOCKING FLUSH RECEPTACLES Engineered for maximum performance with a UL 94 V-O Flammability Rating. Extra thick .050" nickel-plated brass mounting strap Flanged Inlets and Outlets Built to endure hard use with rugged nylon flanges that assure a smooth, flush fit and outstanding resistance to cracking and breaking. 2316 shown Stamped-in agency certifications Color-Coded Voltage Ratings 125V 250V Amperage & voltage rating 277V AC NEMA line number 125/250V 3ø250V 3ø480V Color-coded voltage rating Manufacturer LIFETIME Stability ribs Uni-body face Triple-combo mounting screws 2710 shown Seam between front cover and back cover is far from contact arcing Midget Locking Devices ML1, ML2 and ML3 Locking devices covering the entire spectrum of industrial applications where restrained space considerations are a factor. ML1-C shown Oversized #10 brass Phillips/Robertson/ Straight Slot drive terminal screw Molded-in terminal identification letters Locking Devices Weather-Resistant Boots Feature triple seal action to protect locking plugs and connectors from the harmful effects of dirt and moisture in harsh operations. 6034 shown Multi-termination design Accepts #8º#14 solid or stranded conductors Contacts deeply seated in thick walled faced Specifically developed for wet or damp locations. EPTR thermoplastic rubber body and rugged design resists water, acids, alkalies, grease, oils and solvents. 24W47 shown Mechanically-secured all-brass ground path One-piece ,040" thick brass, high-copper content contacts with nickel-plated clamp type terminals For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 N 3 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com WETGUARD® LOCKING AND CORROSION RESISTANT DEVICE FEATURES Industrial Grade Locking and Corrosion Resistant Devices Cord Ranges .375" min., 1.125" max. Clear back cover on wiring module for easy inspection of wired terminals Locking and Corrosion Resistant Devices Rubber body is molded to bondable nylon substrate to maximize sealing capability LIFETIME NEMA configuration number and rating molded onto device face 26W47 shown Heavy-duty, onepiece nickel-plated brass contacts for maximum conductivity Deep-fluted finger grips make for a firm grip when tightening nut Extra large, deep wiring wells for quick, easy insertion of stranded conductors Module and husk keyed for alignment 27W47 shown Non-magnetic stainless steel body assembly screws prevent electromagnetic interference Combination Phillips/standard assembly screws (Robertson/Slotted for Canada) Nickel-plated brass blades, contacts, wiring screws and lugs resist corrosion Innovative strain relief system and compression nut provide a watertight seal and prevent cord slippage EPTR rubber parts resist water and most acids, alkalies, grease, oil, and solvents. Offers UV stability and resists fungal growth Leviton’s Corrosion Resistant Devices are specifically designed for extremely damp and corrosive environments. They offer additional corrosive resistance because the metal parts (blades, contacts, terminals and screws) are nickel-plated. They have also passed the ASTM (B117.13) 500 hour Salt Spray (Fog) Test. Captive, brass #8 terminal screws are color coded for easy wiring identification WEATHER RESISTANT BOOTS AND COVERS FOR CORROSION RESISTANT DEVICES Weather-resistant boots and covers for plugs and connectors are available for 15A, 20A, 30A and 50A straight and locking plugs and connectors. The tough, rubber triple-seal design protects devices against the harmful effects of dirt and moisture. Thermoplastic covers for 15A, 20A and 30A flush receptacles have close-fitting, spring-loaded lids to protect outlets against the elements in harsh environments. Boots and covers are listed after their appropriate device. Wetguard Products are Engineered to Meet or Exceed UL and IEC Watertight Standards • UL 498 Listed • Federal Specification WC-596 Listed • CSA Specification C22.2 No. 42 Certified • Meets IP and NEMA Watertight Standards Solid brass plug blades held tightly in individual module configurations Plug blades avoid contaminants in interior chamber Non-magnetic stainless steel assembly screws will not interfere with sensitive navigational equipment 52CM-69C shown All current-carrying metal parts (blades, contacts, terminals and screws) are electroless nickel-coated Heavy-duty, impactresistant, super tough ST801 all-nylon body construction, with sure grip fluted design 52CM-66C shown Wiring module keyed to body for easy assembly and tight fit Wire clamp provides positive crimp lock without cutting wire strands Nylon plug and connector body is distinguished by a bright yellow color for easy identification as corrosion resistant Mill-slotted, stainless steel cord clamp screws set in deepfunneled wells N learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 4Courtesy of Steven Engineering,To Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 15 AMP 125V Industrial Grade Locking Devices 15 AMP 125V 2-Pole 3-Wire Grounding U R Ø 1.53 (38.9) NEMA CONFIG. Ø 1.39 (35.3) CAT. NO. 2447 2547 4700 4702-IIR 1.98 (50.4) 4703-IIR L5-15R G G Ø 1.39 (35.3) W W L5-15P Ø 1.53 (38.9) 4720-C 2.76 (70.0) 4729-C Ø 1.53 (38.9) 1.30 (33.0) 2.09 (53.2) 4700-IG 4710 4710-SS 4710-IG 4715-C 4716-C 4720-C 4720-PLC 4720-CA 4720-CB 4720-CY 4729-C 4729-PLC 4729-CB 4729-CY Weather-Resistant Boots for 15A Locking Plugs and Connectors are listed on page N27 Cord Clamp Range—Black & White Plugs and Connectors: .240"–.700" #18–#10 AWG Dustguard Plugs and Connectors: .240"–.655" #18–#12 AWG Wallplates and Covers 302 STAINLESS STEEL SINGLE RECEPTACLE 1.47 (35.7) 302 STAINLESS STEEL DUPLEX RECEPTACLE 1.41" Dia. Opening WEATHER-RESISTANT FLIP LID COVER FOR INLETS AND OUTLETS 4720-CA IP64 Rated—Includes Gasket and Screws Ø 2.50 (63.5) 84003-40 84004-40 Locking Devices DESCRIPTION Dustguard™ Locking Plug, Yellow EPTR Body Dustguard™ Locking Connector, Yellow EPTR Body Duplex Flush Receptacle, Self Grounding, Back and Side Wired Duplex Flush Receptacle w/2 Hot Feeds and 1 Neutral Return, Self Grounding, Back and Side Wired Duplex Flush Receptacle w/Split Feed — 2 Hot Feeds and 2 Neutral Returns, Self Grounding, Back and Side Wired Duplex Flush Receptacle, Isolated Ground, Back and Side Wired Single Flush Receptacle Single Flush Receptacle, w/Short Strap Single Flush Receptacle, Isolated Ground Locking Flanged Outlet Locking Flanged Inlet Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Angle Locking Plug, Black & White Nylon Body Locking Plug, All Black Nylon for Stage and Studio Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, Black Nylon Body Locking Connector, All Black Nylon for Stage and Studio Locking Connector, Yellow Nylon Body WP1 1.78 (43.5) For complete wallplate selection, see Section E. Ø 1.69 (42.8) 4716-C SPECIFICATIONS AND FEATURES Locking Flush Receptacles • Rugged nylon body and cover for outstanding resistance to impact and harsh chemicals • Double-wipe phosphor-bronze power contacts Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life • Power Indication™ 15A Locking Plugs & Connectors equipped with green neon bulb rated at 30,000 hours (24/7) for 3.5 years Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in highabuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands Dustguard Plugs and Connectors • IEC IP44 Rated • Developed to withstand dusty and dirty environments, cracking and fading, temperature extremes • Rugged wiring modules have high performance singlepiece brass triple-wipe contacts, solid brass plug blades TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed. Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 5 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 15 AMP 250V, 277V and 3Ø 250V Industrial Grade Locking Devices 15 AMP 250V 2-Pole 3-Wire Grounding U R 1.30 (33.0) DESCRIPTION Duplex Flush Receptacle, Self Grounding, Back and Side Wired Duplex Flush Receptacle, Isolated Ground, Back and Side Wired Single Flush Receptacle Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Angle Locking Plug, Black & White Nylon Body Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Locking Connector, Yellow Nylon Body Locking Flanged Outlet Locking Flanged Inlet 2.09 (53.2) Ø 1.53 (38.9) 1.47 (35.7) Ø 1.39 (35.3) Ø 1.53 (38.9) 4570-CA Ø 1.53 (38.9) Ø 1.39 (35.3) Locking Devices 4570-CY 2.76 (70.0) NEMA CONFIG. X X L6-15P G L6-15R G Y Y 15 AMP 277V 2-Pole 3-Wire Grounding U R 1.98 (50.4) 4579-CY CAT. NO. 4550 4550-IG 4560 4560-IG 4570-C 4570-PLC 4570-CA 4570-CY 4579-C 4579-PLC 4579-CY 4585-C 4586-C DESCRIPTION Duplex Flush Receptacle, Self Grounding, Back and Side Wired Duplex Flush Receptacle, Isolated Ground, Back and Side Wired Single Flush Receptacle Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Angle Locking Plug, Black & White Nylon Body Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Locking Connector, Yellow Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Locking Flanged Outlet Locking Flanged Inlet CAT. NO. 4750 4570-IG 4760 4760-IG 4770-C 4770-PLC 4770-CA 4770-CY 4779-C 4779-CY 4779-PLC 4785-C 4786-C NEMA CONFIG. W W G G L7-15P L7-15R 15 AMP 3Ø 250V 3-Pole 3-Wire Non-Grounding U Cord Clamp Range—Black & White Plugs and Connectors: .240"–.700" #18–#10 AWG DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body CAT. NO. 4870 4880-C 4889-C NEMA CONFIG. Y L11-15P Y X Z L11-15R X Z Weather-Resistant Boots for 15A Locking Plugs and Connectors are listed on page N27 Wallplates and Covers 302 STAINLESS STEEL SINGLE RECEPTACLE 302 STAINLESS STEEL DUPLEX RECEPTACLE 1.41" Dia. Opening 84004-40 WEATHER-RESISTANT FLIP LID COVER FOR INLETS AND OUTLETS IP64 Rated—Includes Gasket and Screws 84003-40 WP1 For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Locking Flush Receptacles • Rugged nylon body and cover for outstanding resistance to impact and harsh chemicals • Double-wipe phosphor-bronze power contacts Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs N • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life • Power Indication™ 15A Locking Plugs & Connectors equipped with green neon bulb rated at 30,000 hours (24/7) for 3.5 years Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in highabuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94 Operating Temperature: -40°C to 60°C learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 6Courtesy of Steven Engineering,To Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 125V, 250V and 277V Industrial Grade Locking Devices 20 AMP 125V 2-Pole 3-Wire Grounding U R 0.75 (19.1) G L5-20R G 1.06 (26.8) NEMA CONFIG. 2.47 (63.0) X L6-20P X G L6-20R G Y Y Ø 2.08 (52.8) 2311 3.53 (89.7) 2313 Ø 2.88 (73.0) Ø 1.84 (46.8) 20 AMP 277V 2-Pole 3-Wire Grounding U R CAT. NO. 2330 2330-IG 2331 2331-PLC 2333 2333-PLC 2335 2336 NEMA CONFIG. W W L7-20P G L7-20R Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page N27 For recommended Wallplates and Covers, see page N8. For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life • Power Indication™ 20A Locking Plugs & Connectors equipped with green LED rated at 100,000 hours (24/7) for 11.5 years Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands G 2.11 (53.6) DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Locking Connector, Black Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet Locking Devices CAT. NO. 2320 2320-IG 2321 2321-PLC 2321-PLB 2321-CY 2323 2323-PLC 2323-PLB 2323-CY 2325 2326 Ø 2.08 (53.0) 2310 20 AMP 250V 2-Pole 3-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, All-Black Nylon Body Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, All-Black Nylon Body Locking Connector, Yellow Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.67 (67.8) W W L5-20P 3.28 (83.3) 3.63 (92.1) NEMA CONFIG. Ø 1.84 (46.8) CAT. NO. 2310 2310-IG 2311 2311-PLC 2311-B 2311-PLB 2311-CY 2313 2313-PLC 2313-B 2313-PLB 2313-CY 2315 2316 Ø 1.84 (46.8) DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Locking Plug, all Black for Stage and Studio Power Indication™ Locking Plug, All-Black Nylon Body Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Locking Connector, all Black for Stage and Studio Power Indication™ Locking Connector, All-Black Nylon Body Locking Connector, Yellow Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.69 (42.8) Ø 2.05 (52.0) 2316 Cord Clamp Range—Black & White Plugs and Connectors: .385"–.780" #16–#10 AWG TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 7 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 347V, 480V, 600V and 125/250V Industrial Grade Locking Devices 20 AMP 347V 2-Pole 3-Wire Grounding R DESCRIPTION V-O-MAX® Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.67 (67.8) 3.28 (83.3) 3.63 (92.1) 1.69 (42.8) 0.75 (19.1) DESCRIPTION V-O-MAX® Single Flush Receptacle V-O-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet Ø 1.84 (46.8) Ø 2.08 (53.0) 2340 Ø 2.08 (52.8) Ø 1.84 (46.8) Locking Devices 2341 Ø 2.88 (73.0) W W L24-20P L24-20R G G CAT. NO. 2340 2340-IG 2341 2343 2345 2346 NEMA CONFIG. X L8-20P X G L8-20R G Y Y 20 AMP 600V 2-Pole 3-Wire Grounding U R 2.47 (63.0) 2343 NEMA CONFIG. 20 AMP 480V 2-Pole 3-Wire Grounding U R 1.06 (26.8) 3.53 (89.7) CAT. NO. 3720 3721 3723 3755 3756 DESCRIPTION V-O-MAX® Single Flush Receptacle V-O-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2350 2350-IG 2351 2353 2355 2356 NEMA CONFIG. X X G L9-20P L9-20R G Y Y 20 AMP 125/250V 3-Pole 3-Wire Non-Grounding U DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2360 2361 2363 2365 2366 NEMA CONFIG. X L10-20P X W L10-20R Y W Y Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page N27 Cord Clamp Range—Black & White Plugs and Connectors: .385"–.780" #16–#10 AWG 2.11 (53.6) Wallplates and Covers 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 20A INLETS/OUTLETS AND 20A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws Ø 2.05 (52.0) 2365 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 8Courtesy of Steven Engineering,To Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 3Ø 250V, 480V and 125/250V Industrial Grade Locking Devices 20 AMP 3Ø 250V 3-Pole 3-Wire Non-Grounding U NEMA CONFIG. X L11-20R X Z Z 20 AMP 3Ø 480V 3-Pole 3-Wire Non-Grounding U NEMA CONFIG. 1.06 (26.8) Y Y L12-20P X L12-20R X Z 2410-IG Z CAT. NO. 2410 2410-IG 2411 2413 2415 2416 NEMA CONFIG. X L14-20P X W G L14-20R Y 2411 Y CAT. NO. 2420† 2420-IG† 2421 2423 2425 2426 Ø 1.97 (50.0) 20 AMP 3Ø 250V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet NEMA CONFIG. X L15-20P 2.70 (69.0) W G X G Y L15-20R Z G 3.78 (96.0) Y Z 2413 Ø 3.03 (77.0) Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page N27 Locking Devices DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet Ø 1.97 (50.0) 20 AMP 125/250V 3-Pole 4-Wire Grounding U R Ø 2.22 (56.4) CAT. NO. 2380 2381 2383 2385 2386 Ø 2.22 (56.4) DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.67 (67.8) Y Y L11-20P 4.06 (103.2) CAT. NO. 2370 2371 2373 2375 2376 3.28 (83.3) DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.69 (42.8) Cord Clamp Range—Black & White Plugs and Connectors 3-Wire: .385"–.780" #16–#10 AWG 4-Wire: .595"–.895" #14–#10 AWG 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 20A INLETS/OUTLETS AND 20A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws 2.31 (58.7) Wallplates and Covers Ø 2.22 (56.4) 2416 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 9 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 3Ø 480V; 3ØY 120/208V, 277/480V and 347/600V Industrial Grade Locking Devices 20 AMP 3Ø 480V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.67 (67.8) 3.28 (83.3) 3.63 (92.1) 1.69 (42.8) 0.75 (19.1) CAT. NO. 2430 2430-IG 2431 2433 2435 2436 NEMA CONFIG. X X L16-20P G Y L16-20R G Y Z Z 20 AMP 3ØY 120/208V 4-Pole 4-Wire Non-Grounding U Ø 1.97 (50.0) Ø 2.22 (56.4) 2430 DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.06 (26.8) DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.70 (69.0) Ø 2.22 (56.4) Ø 1.97 (50.0) Locking Devices 2433 Ø 3.03 (77.0) NEMA CONFIG. X L18-20P X Y W L18-20R Y W Z Z 20 AMP 3ØY 277/480V 4-Pole 4-Wire Non-Grounding U 2431 3.78 (96.0) CAT. NO. 2440 2441 2443 2445 2446 CAT. NO. 2450 2451 2453 2455 2456 NEMA CONFIG. X X L19-20P Y W L19-20R Y W Z Z 20 AMP 3ØY 347/600V 4-Pole 4-Wire Non-Grounding U DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2460 2461 2463 2465 2466 NEMA CONFIG. X X L20-20P W Y L20-20R Z Y W Z Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page N27 Cord Clamp Range—Black & White Plugs and Connectors: .595"–.895" #14–#10 AWG 2.31 (58.7) Wallplates and Covers 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 20A INLETS/OUTLETS AND 20A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws Ø 2.22 (56.4) 84020-40 2435 WP2 for Inlets/Outlets 7420-CR for Receptacles 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 10 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 3ØY 120/208V, 277/480V and 347/600V Industrial Grade Locking Devices 20 AMP 3ØY 120/208V 4-Pole 5-Wire Grounding U R NEMA CONFIG. X X Y W G L21-20R Y W 2.38 (60.3) L21-20P G 3.62 (92.1) CAT. NO. 2510 2510-IG 2511 2513 2515 2516 Z Z 3.28 (83.3) DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.70 (43.3) 0.75 (19.1) 20 AMP 3ØY 277/480V 4-Pole 5-Wire Grounding U R NEMA CONFIG. 2510 X L22-20P Y X W G L22-20R W Y G Z Z 20 AMP 3ØY 347/600V 4-Pole 5-Wire Grounding U R NEMA CONFIG. 2.70 (68.7) 2511 X X W G L23-20R Z Y W G Z Ø 2.22 (56.4) L23-20P Y Ø 1.97 (50.0) CAT. NO. 2530 2530-IG 2531 2533 2545 2546 Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page N27 Cord Clamp Range—Black & White Plugs and Connectors: .595"–.895" #14–#10 AWG 3.78 (96.0) Wallplates and Covers 2513 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 20A INLETS/OUTLETS AND 20A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles Locking Devices DESCRIPTION Single Flush Receptacle Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.13 (28.6) Ø 2.22 (56.4) CAT. NO. 2520 2520-IG 2521 2523 2525 2526 Ø 1.97 (50.0) DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickel-plated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 11 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 125V, 250V and 277V Industrial Grade Locking Devices 30 AMP 125V 2-Pole 3-Wire Grounding U R 3.63 (92.1) 3.28 (83.3) 2.67 (67.8) 1.69 (42.8) 0.75 (19.1) 1.06 (26.8) Ø 1.84 (46.8) Ø 2.08 (52.8) 2620 2.47 (62.9) Ø 2.88 (73.0) 2.11 (53.6) Locking Devices 2621-B DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Locking Plug, All Black for Stage and Studio Power Indication™ Locking Plug, All-Black Nylon Body Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Locking Connector, All Black for Stage and Studio Power Indication™ Locking Connector, All-Black Nylon Body Locking Connector, Yellow Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2610 2610-IG 2611 2611-PLC 2611-B 2611-PLB 2611-CY 2613 2613-PLC 2613-B 2613-PLB 2613-CY 2615 2616 NEMA CONFIG. W L5-30P W G L5-30R G 30 AMP 250V 2-Pole 3-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Power Indication™ Locking Plug, Black & White Nylon Body Locking Plug, All Black for Stage and Studio Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Power Indication™ Locking Connector, Black & White Nylon Body Locking Connector, All Black for Stage and Studio Locking Connector, Yellow Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2620 2620-IG 2621 2621-PLC 2621-B 2621-CY C2623 2623-PLC C2623-B C2623-CY 2625F 2626F NEMA CONFIG. X L6-30P X G L6-30R G Y Y 30 AMP 277V 2-Pole 3-Wire Grounding U R Ø 2.05 (52.0) 2625F Cord Clamp Range—Black & White Plugs and Connectors: .385"–.860" #16–#8 AWG DESCRIPTION CAT. NO. NEMA CONFIG. V-0-MAX® Single Flush Receptacle 2630 V-0-MAX® Single Flush Receptacle, Isolated Ground 2630-IG Locking Plug, Black & White Nylon Body 2631 Power Indication™ Locking Plug, Black & White Nylon Body 2631-PLC L7-30P L7-30R Locking Connector, Black & White Nylon Body 2633 Power Indication™ Locking Connector, Black& White Nylon Body 2633-PLC Locking Flanged Inlet 2635 Locking Flanged Outlet 2636 Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27 W W G G For recommended Wallplates and Covers, see page N13. For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals N • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life • Power Indication™ 30A Locking Plugs & Connectors equipped with green LED rated at 100,000 hours (24/7) for 11.5 years Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 12 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 480V, 600V, 125/250V and 3Ø 250V Industrial Grade Locking Devices 30 AMP 480V 2-Pole 3-Wire Grounding U R 0.75 (19.1) NEMA CONFIG. X L8-30R G Y 2.67 (67.8) X L8-30P G 3.63 (92.1) CAT. NO. 2640 2640-IG 2641 2643 2645 2646 Y 2.38 (83.3) DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.69 (42.8) 30 AMP 600V 2-Pole 3-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2650 2650-IG C2651 C2653 2655 2656 NEMA CONFIG. 1.06 (26.8) 2650-A X X L9-30P G L9-30R G Y Y Ø 2.88 (73.0) 30 AMP 125/250V 3-Pole 3-Wire Non-Grounding U NEMA CONFIG. X 2.11 (53.6) CAT. NO. 2660 2661 2663 2665 2666 X L10-30P W L10-30R W Y Y Ø 2.05 (52.0) 30 AMP 3Ø 250V 3-Pole 3-Wire Non-Grounding U DESCRIPTION V-0-MAX® Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2656 CAT. NO. 2670 2671 2673 2675 2676 NEMA CONFIG. Y Y L11-30P X L11-30R X Z Z Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27 Locking Devices DESCRIPTION V-0-MAX® Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet Cord Clamp Range—Black & White Plugs and Connectors: .385"–.860" #16–#8 AWG Wallplates and Covers 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 30A INLETS/OUTLETS AND 30A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickel-plated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 13 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 3Ø 480V, 3Ø 600V, 3Ø 250V and 125/250V Industrial Grade Locking Devices 30 AMP 3Ø 480V 3-Pole 3-Wire Non-Grounding U 1.69 (42.8) DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.67 (67.8) 3.28 (83.30 3.63 (92.1) 0.75 (19.1) DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.06 (26.8) Ø 2.22 (56.4) Ø 1.97 (50.0) 2.70 (68.7) Ø 2.22 (56.4) Ø 1.97 (50.0) Locking Devices Ø 3.03 (77.0) Y Y L12-30P X L12-30R X Z Z CAT. NO. 2690 2691 2693 2695 2696 NEMA CONFIG. Y Y L13-30P X L13-30R X Z Z 30 AMP 125/250V 3-Pole 4-Wire Grounding U R 2711 2713 NEMA CONFIG. 30 AMP 3Ø 600V 3-Pole 3-Wire Non-Grounding U 2710 3.78 (96.0) CAT. NO. 2680 2681 2683 2685 2686 DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Plug, Yellow Nylon Body Locking Connector, Black & White Nylon Body Locking Connector, Yellow Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2710 2710-IG 2711 2711-CY 2713 2713-CY 2715 2716 NEMA CONFIG. X L14-30P W X G L14-30R W G Y Y 30 AMP 3Ø 250V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2720 2720-IG 2721 2723 2725 2726 NEMA CONFIG. X X L15-30P G Y L15-30R Z G Y Z Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27 2.31 (58.7) Cord Clamp Range—Black & White Plugs and Connectors 3-Wire: .385"–.860" #16–#8 AWG 4-Wire: .595"–1.150" #14–#8 AWG Wallplates and Covers 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 30A INLETS/OUTLETS AND 30A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws Ø 2.22 (56.3) 2715 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES N V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 14 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 3Ø 480V, 3Ø 600V, 3ØY 120/208V and 3ØY 277/480V Industrial Grade Locking Devices 30 AMP 3Ø 480V 3-Pole 4-Wire Grounding U R NEMA CONFIG. X L16-30P X G Y L16-30R G Y Z 2.67 (67.8) CAT. NO. 2730 2730-IG 2731 2733 2735 2736 4.06 (103.2) 3.28 (83.3) DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.69 (42.8) Z 30 AMP 3Ø 600V 3-Pole 4-Wire Grounding U R 1.06 (26.8) NEMA CONFIG. 2730-IG X X L17-30P Y G L17-30R Y G Z Z 30 AMP 3ØY 120/208V 4-Pole 4-Wire Non-Grounding U NEMA CONFIG. 2.70 (68.7) 2731 X X Y W L18-30R Y W Z Z 30 AMP 3ØY 277/480V 4-Pole 4-Wire Non-Grounding U DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2760 2761 2763 2765 2766 Ø 2.22 (56.4) L18-30P Ø 1.97 (50.0) CAT. NO. 2750 2751 2753 2755 2756 NEMA CONFIG. 3.78 (96.0) X X L19-30P W Y L19-30R Z 2733 Y W Z Ø 3.03 (77.0) Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27 Locking Devices DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet Ø 2.22 (56.4) CAT. NO. 2740 2740-IG 2741 2743 2745 2746 Ø 1.97 (50.0) DESCRIPTION Single Flush Receptacle Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet Cord Clamp Range—Black & White Plugs and Connectors: .595"–1.150" #14–#8 AWG 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 30A INLETS/OUTLETS AND 30A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws 2.31 (58.7) Wallplates and Covers Ø 2.22 (56.4) 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles 2736 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES V-O-Max® Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickelplated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 15 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 3ØY 347/600V, 3ØY 120/208V and 3ØY 277/480V Industrial Grade Locking Devices 1.70 (43.3) 30 AMP 3ØY 347/600V 4-Pole 4-Wire Non-Grounding U DESCRIPTION Single Flush Receptacle Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2.39 (60.7) 3.28 (63.3) 3.62 (92.1) 0.75 (19.1) NEMA CONFIG. X L20-30P X Y W L20-30R Y W Z Z 30 AMP 3ØY 120/208V 4-Pole 5-Wire Grounding U R DESCRIPTION V-0-MAX® Single Flush Receptacle V-0-MAX® Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 1.13 (28.6) Ø 1.97 (50.0) Ø 2.22 (56.4) 2810 Ø 2.22 (56.4) 2811 Ø 1.97 (50.0) CAT. NO. 2810 2810-IG 2811 2813 2815 2816 NEMA CONFIG. X X L21-30P W Y G L21-30R Y W G Z Z 30 AMP 3ØY 277/480V 4-Pole 5-Wire Grounding U R 2.70 (68.7) 3.78 (96.0) DESCRIPTION Single Flush Receptacle Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 2820 2820-IG 2821 2823 2825 2826 Ø 3.03 (77.0) NEMA CONFIG. X X L22-30P Y W G L22-30R Y W G Z Z 30 AMP 3ØY 347/600V 4-Pole 5-Wire Grounding U R DESCRIPTION Single Flush Receptacle Single Flush Receptacle, Isolated Ground Locking Plug, Black & White Nylon Body Locking Connector, Black & White Nylon Body Locking Flanged Inlet Locking Flanged Outlet 2813 CAT. NO. 2830 2830-IG 2831 2833 2835 2836 NEMA CONFIG. X X L23-30P Y W G L23-30R Z Y W G Z Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27 Wallplates and Covers 2.31 (58.7) Locking Devices CAT. NO. 2770 2771 2773 2775 2776 302 STAINLESS STEEL SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 30A INLETS/OUTLETS AND 30A RECEPTACLES WEATHER-RESISTANT THERMOPLASTIC COVER FOR RECEPTACLES 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws Self-Closing Lid—Includes Gasket and Screws Ø 2.22 (56.4) 2816 Cord Clamp Range—Black & White Plugs and Connectors: .595"–1.150" #14–#8 AWG 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles 4980-GY For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Locking Flush Receptacles • UL 94 V-O Flammability Rating, the best rating of any material used in Industrial Locking Flush Receptacles available today • Extra-thick .050" nickel-plated brass mounting strap for high-abuse applications • Designed for maximum durability: One-piece .040" brass, high copper-content contacts with nickel-plated clamp-type terminals • Color-coded voltage rating on face for easy identification Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C to 60°C N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 16 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 15 & 20 AMP 125V, 250V and 277V Wetguard Locking Plugs and Connectors U R DESCRIPTION Yellow EPTR, 15A-125V 2-Pole, 3-Wire Black EPTR Yellow EPTR, 15A-250V 2-Pole, 3-Wire CAT. NO. PLUG 24W47 CAT. NO. CONNECTOR 25W47 W W L5-15P 24W47-B 24W49 G G 25W47-B 25W49 X L6-15R G 24W47 X G Y Yellow EPTR, 20A-125V 2-Pole, 3-Wire Black EPTR Yellow EPTR, 20A-250V 2-Pole, 3-Wire Black EPTR Yellow EPTR, 20A-277V 2-Pole, 3-Wire 26W47 Y W 25W34 G L7-15P 27W47 W G W L5-20R G 27W47B 27W48 X L6-20P 26W48-B 26W49 G L7-15R L5-20P 26W47B 26W48 W L6-20R G X G 27W48-B 27W49 Y W Y W G G L7-20R L7-20P 4.11 (104.4) 24W34 2.71 (68.8) L5-15R L6-15P Yellow EPTR, 15A-277V 2-Pole, 3-Wire Ø 1.50 (38.1) Wetguard® Devices Engineered to IP66 & IP67 Watertight Standards Replacement Closure Cap CAT. NO. YELLOW 50W50 50W52 14W 26W CAT. NO. BLACK 50W50-B 50W52-B 14W-B 26W-B Ø 2.30 (58.3) Ø 2.31 (58.7) 25W47 Cord Clamp Range—Wetguard® Locking Plugs and Connectors 15A: .375"–.655" #18–#10 AWG 20A: .375"–.875" #18–#10 AWG 3.58 (91.0) Locking Devices DESCRIPTION Connector Cap for 15A devices Connector Cap for 20A devices Plug Cap for 15A devices Plug Cap for 20A devices Ø 1.28 (32.5) Industrial Grade Wetguard® Locking Devices 26W47 SPECIFICATIONS AND FEATURES Wetguard • Multi-point sealing system utilizes nut, strain relief washer and rubber bushing to form a watertight • IEC IP66 and IP 67 Rated, in accordance with IEC cord grip seal 529 as evaluated by UL and CSA • NEMA Type 4, 4X, 6 and 6P Ratings in accordance • Non-magnetic stainless steel fast-threading assembly screws won’t interfere with sensitive equipment with UL 50 and CSA 94 • EPTR rubber parts provide outstanding resistance to • Connector “hood” closure cap seals device when not in use wet and damp environments, extreme temperature variations, acids, alkalis, grease, oils and solvents • Interlocking “tongue and groove” construction seals out water, moisture, dirt when plugs are mated with connectors TESTING AND CODE COMPLIANCE • Meet NEMA WD 1 & 6, ANSI requirements • UL Listed & meets Fed. Spec. requirements: (File #13393) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability, Rated V2 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 17 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 125/250V; 3Ø 250V, 480V, 3ØY 120/208V, 277/480V and 347/600V Ø 2.31 (58.7) Industrial Grade Wetguard® Locking Devices Wetguard® Devices Engineered to IP66 & IP67 Watertight Standards Wetguard Locking Plugs and Connectors U R 3.58 (91.0) 26W81 DESCRIPTION Yellow EPTR, 20A-125/250V 3-Pole, 4-Wire CAT. NO. PLUG 26W74 L14-20P CAT. NO. CONNECTOR 27W74 X X W G L14-20R W G Y Yellow EPTR, 20A-3Ø 250V 3-Pole, 4-Wire Black EPTR Yellow EPTR, 20A-3Ø 480V 3-Pole, 4-Wire Black EPTR Yellow EPTR, 20A-3ØY 120/208V 4-Pole, 5-Wire Black EPTR Yellow EPTR, 20A-3ØY 277/480V 4-Pole, 5-Wire Y 26W75 27W75 X L15-20P G Y 26W75-B 26W76 X G Y 26W76-B 26W81 X Y W G 26W81-B 26W82 L16-20R X G Y L21-20R Z X Y W G 27W81-B 27W82 Z X Y L22-20P Y Z 27W76-B 27W81 Z L21-20P G 27W75-B 27W76 Z L16-20P X L15-20R W G L22-20R Z X Y W G Z Yellow EPTR, 20A-3ØY 347/600V 4-Pole, 5-Wire 26W83 Z 27W83 X L23-20P Y W G X L23-20R Y W G Z Wetguard Non-NEMA, Non-Grounding Devices (Not UL Listed–For Replacement Use Only) Ø 2.50 (63.3) DESCRIPTION Yellow EPTR, 20A-125/250V 3-Pole, 3-Wire CAT. NO. PLUG 26W08 Yellow EPTR, 20A-3ØY 120/208V 4-Pole, 4-Wire 26W09 NONNEMA CAT. NO. CONNECTOR 27W08 X X Y W Y W 27W09 W NONNEMA NONNEMA X Z Y W NONNEMA X Y Z 27W81 Replacement Closure Cap DESCRIPTION Connector Cap for 20A devices Plug Cap for 20A devices Ø 2.31 (58.7) Locking Devices 5.46 (138.7) Z 3.58 (91.0) CAT. NO. YELLOW 50W52 26W CAT. NO. BLACK 50W52-B 26W-B Cord Clamp Range—Wetguard® 20A Locking Plugs and Connectors: .375"–.875" #18–#10 AWG 26W81-B SPECIFICATIONS AND FEATURES Wetguard • Multi-point sealing system utilizes nut, strain relief washer and rubber bushing to form a watertight • IEC IP66 and IP 67 Rated, in accordance with IEC cord grip seal 529 as evaluated by UL and CSA • Non-magnetic stainless steel fast-threading assembly • NEMA Type 4, 4X, 6 and 6P Ratings in accordance screws won’t interfere with sensitive equipment with UL 50 and CSA 94 • EPTR rubber part provide outstanding resistance to • Connector “hood” closure cap seals device when not in use wet and damp environments, extreme temperature variations, acids, alkalis, grease, oils and solvents • Interlocking “tongue and groove” construction seals out water, moisture, dirt when plugs are mated with connectors TESTING AND CODE COMPLIANCE • Meet NEMA WD 1 & 6, ANSI requirements • UL Listed & meets Fed. Spec. requirements: (File #13393) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability, Rated V2 Operating Temperature: -40°C to 60°C N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 18 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 125V, 250V, 277V, 125/250V; 3Ø 250V, 480V, 600V; 3ØY 120/208V, 277/480V, 347/600V Wetguard® Devices Engineered to IP66 & IP67 Watertight Standards Wetguard Locking Plugs and Connectors U R CAT. NO. PLUG 28W47 CAT. NO. CONNECTOR 29W47 W G 28W47-B 28W48 L5-30R G 28W47 29W47-B 29W48 X L6-30P G L6-30R X G Y Yellow EPTR, 30A-277V 2-Pole, 3-Wire 28W49 Yellow EPTR, 30A-125/250V 3-Pole, 4-Wire 28W74 Y 29W49 W L7-30P L14-30P G G 29W74 X W L7-30R W G L14-30R X W G Y Y 28W75 G Y 28W75-B 28W76 L16-30P X G Y X Y G 28W77-B 28W81 X G Y X G Y L17-30R Z X Y G 29W77-B 29W81 Z X W Y L16-30R Z 29W76-B 29W77 Z L17-30P L15-30R 29W75-B 29W76 Z 28W76-B 28W77 L21-30P 29W75 X L15-30P G L21-30R Z X Y W G Z Z Yellow EPTR, 30A-3ØY 277/480V 4-Pole, 5-Wire 28W82 L22-30P 29W82 X Y W G L22-30R X Y W Z Yellow EPTR, 30A-3ØY 347/600V 4-Pole, 5-Wire 28W83 L23-30P Z 29W83 X Y W G Ø 2.75 (69.9) G L23-30R 29W47 X Y W G Z Z Wetguard Non-NEMA, Non-Grounding Devices (Not UL Listed–For Replacement Use Only) DESCRIPTION Yellow EPTR, 30A-125/250V 3-Pole, 3-Wire CAT. NO. PLUG 28W08 Yellow EPTR, 30A-3ØY 120/208V 4-Pole, 4-Wire 28W09 NON-NEMA CAT. NO. CONNECTOR 29W08 NON-NEMA Locking Devices Yellow EPTR, 30A-3Ø 250V 3-Pole, 4-Wire Black EPTR Yellow EPTR, 30A-3Ø 480V 3-Pole, 4-Wire Black EPTR Yellow EPTR, 30A-3Ø 600V 3-Pole, 4-Wire Black EPTR Yellow EPTR, 30A-3ØY 120/208V 4-Pole, 5-Wire 3.62 (92.0) W L5-30P 5.46 (138.7) DESCRIPTION Yellow EPTR, 30A-125V 2-Pole, 3-Wire Black EPTR Yellow EPTR, 30A-250V 2-Pole, 3-Wire Ø 2.53 (64.3) Industrial Grade Wetguard® Locking Devices 29W09 NON-NEMA NON-NEMA CAT. NO. YELLOW 50W54 28W CAT. NO. BLACK 50W54-B 28W-B DESCRIPTION Connector Cap for 30A devices Plug Cap for 30A devices Cord Clamp Range—Wetguard® 30A Locking Plugs and Connectors: .625"–1.125" #12–#8 AWG 5.46 (138.7) Replacement Closure Cap Ø 2.75 (69.9) 29W47-B SPECIFICATIONS AND FEATURES Wetguard • Multi-point sealing system utilizes nut, strain relief washer and rubber bushing to form a watertight • IEC IP66 and IP 67 Rated, in accordance with IEC cord grip seal 529 as evaluated by UL and CSA • Non-magnetic stainless steel fast-threading assembly • NEMA Type 4, 4X, 6 and 6P Ratings in accordance screws won’t interfere with sensitive equipment with UL 50 and CSA 94 • EPTR rubber parts provide outstanding resistance to • Connector “hood” closure cap seals device when not in use wet and damp environments, extreme temperature variations, acids, alkalis, grease, oils and solvents • Interlocking “tongue and groove” construction seals out water, moisture, dirt when plugs are mated with connectors TESTING AND CODE COMPLIANCE • Meet NEMA WD 1 & 6, ANSI requirements • UL Listed & meets Fed. Spec. requirements: (File #13393) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability, Rated V2 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 19 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 15 AMP 125V, 250V and 277V Industrial Grade Corrosion Resistant Devices Ø 1.39 (35.3) Ø 1.53 (38.9) 15 AMP 125V 2-Pole 3-Wire Grounding U R 1.98 (50.4) Ø 1.39 (35.3) Ø 1.53 (38.9) 52CM-66C 1.98 (50.4) DESCRIPTION Straight Blade Plug, Yellow Nylon Body and Cord Clamp Straight Blade Connector, Yellow Nylon Body and Cord Clamp Duplex Receptacle, Smooth Face. One-Piece Electroless Nickel-Plated Brass Strap Single Receptacle, Smooth Face, Yellow Nylon Body Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp Single Locking Flush Receptacle CAT. NO. 52CM-66C 52CM-69C 52CM-62 NEMA CONFIG. 5-15P 5-15R W 5-15R 5261-CR 47CM-20C 47CM-29C 47CM-10 5-15R L5-15P L5-15R L5-15R DESCRIPTION Single Receptacle, Smooth Face, Yellow Nylon Body CAT. NO. 5661-CR NEMA CONFIG. 6-15R Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp Single Locking Flush Receptacle† 45CM-70C 45CM-79C 45CM-60 L6-15P L6-15R L6-15R CAT. NO. 47CM-60 NEMA CONFIG. L7-15R G G W 5-15P 5-15R W W G G L5-15P L5-15R 15 AMP 250V 2-Pole 3-Wire Grounding U R G G 6-15P 6-15R Ø 1.53 (38.9) Ø 1.39 (35.3) Corrosion Resistant Devices 47CM-20C 2.76 (70.1) X X G G Y Y L6-15P L6-15R 15 AMP 277V AC 2-Pole 3-Wire Grounding U R DESCRIPTION Single Locking Flush Receptacle W W G G 47CM-29C L7-15P L7-15R Weather-Resistant Boots for 15A Locking Plugs and Connectors are listed on page N27 Cord Clamp Range—15A St. Blade/Locking Plugs and Connectors: .240"–.700" #18–#10 AWG Wallplates and Covers 302 STAINLESS STEEL FOR 15A/20A ST. BLADE/15A SINGLE LOCKING RECEPTACLE 302 STAINLESS STEEL FOR 15A/20A ST. BLADE DUPLEX RECEPTACLE 1.41" Dia. Opening IP64 Rated—Includes Gasket and Screws 84003-40 84004-40 WETGUARD COVER AND GASKET FOR 15A/20A ST. BLADE/15A LOCKING DEVICES WEATHER-RESISTANT FLIP LID COVER FOR 15A/20A ST. BLADE/15A LOCKING DEVICES WP1 BLANK PLATE W/GASKET FD BOX GLASS-FILLED POLYESTER (2 KO OPENINGS) WP459 Yellow 452CR Yellow 1/2", 453CR Yellow 3/4", 454CR Yellow 1" IP66 Rated 60W03 Yellow, 60W03-B Black For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Plugs and Connectors • All current-carrying metal parts (blades, contacts, terminals and screws) are electroless nickel-coated • Captive, brass #8 terminal screws are color coded for easy wiring identification: green (ground), brass (hot) and silver (neutral) • Super tough nylon plug and connector body is bright yellow for easy corrosion resistant identification • Connector power contacts are heavy-duty, solid, one-piece brass, triple-wipe, set in deep pockets to resist rough use • Heavy-duty, impact-resistant, super tough ST801 all-nylon body construction; fluted body design provides sure grip • Wire clamp moves in individual chamber to provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • Plugs and connectors pass the ASTM B117-13 five-hundred hour Salt Spray (Fog) Test with no visible corrosion • Designed to meet or exceed UL Fed Spec. Listing WC-596. UL Listed (File #E-13399 for Receptacles; File #E-13393 for Plugs and Connectors) • CSA Certified (File #LR-406) • NOM Certified (#057) • Meets NEMA WD1 & WD6 requirements • NEMA configuration and rating molded on front • Backed by a Limited 10-Year Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL 94 Operating Temperature: -40°C (without impact) to 60°C maximum continuous N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 20 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 125V, 250V, 277V, 125/250V and 3Ø 250V, 480V DESCRIPTION Straight Blade Plug, Yellow Nylon Body and Cord Clamp Straight Blade Connector, Yellow Nylon Body and Cord Clamp Duplex Receptacle, smooth face. One Piece Electroless Nickel-Plated Brass Strap Single Receptacle, Smooth Face, Yellow Nylon Body Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp V-0-MAX® Single Locking Flush Receptacle CAT. NO. 53CM-66C 53CM-69C 53CM-62 NEMA CONFIG. 5-20P 5-20R W 5-20R G W G Ø 1.84 (46.8) 20 AMP 125V 2-Pole 3-Wire Grounding U R Ø 2.08 (53.0) Industrial Grade Corrosion Resistant Devices 2.47 (63.0) 5-20P 5-20R 23CM-11 5361-CR 23CM-11 23CM-13 23CM-10 5-20R L5-20P L5-20R L5-20R DESCRIPTION Single Receptacle, Smooth Face, Yellow Nylon Body CAT. NO. 5461-CR NEMA CONFIG. 6-20R G G 6-20P 6-20R V-0-MAX® Single Locking Flush Receptacle 23CM-20 L6-20R W W G 1.69 (42.8) G L5-20P 0.75 (19.1) L5-20R X X G G Y Y L6-20P 1.06 (26.8) L6-20R 23CM-10 DESCRIPTION V-0-MAX® Single Locking Flush Receptacle CAT. NO. 23CM-30 NEMA CONFIG. L7-20R W W G Cord Clamp Range— 20A St. Blade/3-Wire Locking Plugs and Connectors: .240"–.700" #18–#10 AWG 20A 4-Wire Locking Plugs and Connectors: .595"–.895" #14–#10 AWG G L7-20P L7-20R 20 AMP 125/250V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Locking Flush Receptacle CAT. NO. 24CM-10 NEMA CONFIG. L14-20R X W X G SPECIFICATIONS AND FEATURES W G Y Y L14-20P L14-20R 20 AMP 3Ø 250V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Locking Flush Receptacle CAT. NO. 24CM-20 NEMA CONFIG. L15-20R X X G Y G Y Z Z L15-20P L15-20R 20 AMP 3Ø 480V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Locking Flush Receptacle CAT. NO. 24CM-30 NEMA CONFIG. L16-20R X X G Y Z L16-20P G Y Z L16-20R TESTING AND CODE COMPLIANCE Weather-Resistant Boots for 20A Locking Plugs and Connectors are listed on page N27 Wallplates and Covers 302 STAINLESS STEEL 20A SINGLE LOCKING RECEPTACLE WEATHER-RESISTANT FLIP LID COVER 20A SINGLE LOCKING RECEPTACLE WETGUARD COVER AND GASKET 20A SINGLE LOCKING RECEPTACLE 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws IP66 Rated WP2 BLANK PLATE W/GASKET 7420-CR Plugs and Connectors • All current-carrying metal parts (blades, contacts, terminals and screws) are electroless nickel-coated • Captive, brass #8 terminal screws are color coded for easy wiring identification: green (ground), brass (hot) and silver (neutral) • Super tough nylon plug and connector body is bright yellow for easy corrosion resistant identification • Connector power contacts are heavy-duty, solid, one-piece brass, triple-wipe, set in deep pockets to resist rough use • Heavy-duty, impact-resistant, all-nylon body construction; fluted body design provides sure grip • Wire clamp moves in individual chamber to provide positive crimp lock without cutting wire strands Corrosion Resistant Devices 20 AMP 277V AC 2-Pole 3-Wire Grounding U R 84020-40 2.67 (67.8) 3.28 (83.3) 3.63 (92.1) 20 AMP 250V 2-Pole 3-Wire Grounding U R 60W04 Yellow, 60W04-B Black FD BOX GLASS-FILLED POLYESTER (2 KO OPENINGS) • Plugs and connectors pass the ASTM B117-13 five-hundred hour Salt Spray (Fog) Test with no visible corrosion • Designed to meet or exceed UL Fed Spec. Listing WC-596. UL Listed (File #E-13399 for Receptacles; File #E-13393 for Plugs and Connectors) • CSA Certified (File #LR-406) • NOM Certified (#057) • Meets NEMA WD1 & WD6 requirements • NEMA configuration and rating molded on front • Backed by a Limited 10-Year Warranty MATERIAL CHARACTERISTICS WP459 Yellow 452CR Yellow 1/2", 453CR Yellow 3/4", 454CR Yellow 1" Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C (without impact) to 60°C maximum continuous For complete wallplate selection, see Section E. N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 21 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 125V, 250V, 125/250V and 3Ø 250V Ø 1.84 (46.8) Ø 2.08 (52.8) Industrial Grade Corrosion Resistant Devices 2.47 (63.0) 30 AMP 125V 2-Pole 3-Wire Grounding U R DESCRIPTION Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp V-0-MAX® Single Locking Flush Receptacle CAT. NO. 26CM-11 26CM-13 26CM-10 NEMA CONFIG. L5-30P L5-30R L5-30R L5-30P CAT. NO. 26CM-21 26CM-23 26CM-20 NEMA CONFIG. L6-30P L6-30R L6-30R L6-30P CAT. NO. 27CM-10 NEMA CONFIG. L14-30R W W G G L5-30R 30 AMP 250V 2-Pole 3-Wire Grounding U R 26CM-11 DESCRIPTION Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp Single Locking Flush Receptacle 1.69 (42.8) 0.75 (19.1) X X G G Y Y L6-30R 2.67 (67.8) 2.38 (83.3) 3.63 (92.1) 30 AMP 125/250V 3-Pole 4-Wire Grounding U R DESCRIPTION V-0-MAX® Single Locking Flush Receptacle X W X G W G Y Y L14-30P L14-30R Corrosion Resistant Devices 30 AMP 3Ø 250V 3-Pole 4-Wire Grounding U R 1.06 (26.8) 26CM-10 DESCRIPTION V-0-MAX® Single Locking Flush Receptacle CAT. NO. 27CM-20 NEMA CONFIG. L15-30R X X G Y G Y Z Z L15-30P L15-30R Weather-Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27 Cord Clamp Range—30A 3-Wire Locking Plugs and Connectors: .385"–.860" #16–#8 AWG 30A 4-Wire Locking Plugs and Connectors: .595"–1.150" #14–#8 AWG Wallplates and Covers 302 STAINLESS STEEL 30A SINGLE LOCKING RECEPTACLE WEATHER-RESISTANT FLIP LID COVER 30A SINGLE LOCKING RECEPTACLE WETGUARD COVER AND GASKET 30A SINGLE LOCKING RECEPTACLE 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws IP66 Rated 84020-40 WP2 7420-CR 60W05 Yellow, 60W05-B Black BLANK PLATE W/GASKET FD BOX GLASS-FILLED POLYESTER (2 KO OPENINGS) WP459 Yellow 452CR Yellow 1/2", 453CR Yellow 3/4", 454CR Yellow 1" For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Plugs and Connectors • All current-carrying metal parts (blades, contacts, terminals and screws) are electroless nickel-coated • Captive, brass #8 terminal screws are color coded for easy wiring identification: green (ground), brass (hot) and silver (neutral) • Nylon plug and connector body is bright yellow for easy corrosion resistant identification • Connector power contacts are heavy-duty, solid, one-piece brass, triple-wipe, set in deep pockets to resist rough use • Heavy-duty, impact-resistant, all-nylon body construction; fluted body design provides sure grip • Wire clamp moves in individual chamber to provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • Plugs and connectors pass the ASTM B117-13 fivehundred hour Salt Spray (Fog) Test with no visible corrosion • Designed to meet or exceed UL Fed Spec. Listing WC-596. UL Listed (File #E-13399 for Receptacles; File #E-13393 for Plugs and Connectors) • CSA Certified (File #LR-406) • NOM Certified (#057) • Meets NEMA WD1 & WD6 requirements • NEMA configuration and rating molded on front • Backed by a Limited 10-Year Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94, V-O-MAX® Receptacles Rated V0 Operating Temperature: -40°C (without impact) to 60°C maximum continuous N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 22 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 50 AMP 125V, 125/250V Industrial Grade Corrosion Resistant Devices CAT. NO. 6361-CR 6360-CR 6370-CR 6372-CR NEMA CONFIG. W Ø 1.99 (50.5) DESCRIPTION Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp Single Locking Flush Receptacle Power Inlet, 316 Stainless Steel w/Threaded Cap W G Ø 2.38 (60.5) 50 AMP 125V 2-Pole 3-Wire Grounding U R G 4.97 (126.2) 50 AMP 125/250V 3-Pole 4-Wire Grounding U R DESCRIPTION Locking Plug, Yellow Nylon Body and Cord Clamp Locking Connector, Yellow Nylon Body and Cord Clamp Single Locking Flush Receptacle Power Inlet, 316 Stainless Steel w/Threaded Cap 6364-CR CAT. NO. 6365-CR 6364-CR 6369-CR 6374-CR NEMA CONFIG. Y Y X GR W X W GR Boots and Covers for 50 AMP Corrosion Resistant Devices CAT. NO. 7715-CRY 7715-CR 7717-CRY 7717-CR 7788-CR 7788-CR Corrosion Resistant Devices DESCRIPTION 50A Locking Plug Boot, High Visibility Yellow 50A Locking Plug Boot, Black 50A Locking Connector Boot, High Visibility Yellow 50A Locking Connector Boot, High Visibility Yellow Weather-Resistant Receptacle Flip Lid Cover, IP64 rated, Yellow Lexan Cast Aluminum Grey Flip Lid Cover, IP64 rated 7770 Cord Clamp Range—50A CR Locking Plugs and Connectors: .650"–1.125" #10–#4 AWG SPECIFICATIONS AND FEATURES • All current-carrying metal parts (blades, contacts, terminals and screws) are electroless nickel-coated • Color coded wire entrance holes for simple and easy wiring • Nylon plug and connector body are bright yellow for easy corrosion resistant identification • Nylon housing for excellent impact resistance and secure gripping • Boots are IP55 Rated • Longer contacts inside connector assure stronger, tighter fitting contact points • Backed by a lifetime warranty • External cord clamp with cable insert accomodates from smallest to largest wire size • Covers are IP64 rated for wet location with cover closed TESTING AND CODE COMPLIANCE • NOM Certified (#057) • CSA Certified (File# 152105) Receptacles • UL Listed (File #E-111198) Plugs & Connectors and Inlets • UL Listed (File #E-57672) MATERIAL CHARACTERISTICS Operating Temperature: -40°C to 75°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 23 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 15 AMP 125V/10A-250; 20 AMP 250V, 125/250V and 3ØY 120/208V Industrial Grade Non-NEMA Locking Devices 1.70 (43.3) 15 AMP 125V/10A-250V 3-Pole 3-Wire Non-Grounding Non-NEMA† DESCRIPTION Single Flush Receptacle† Locking Plug Locking Connector† Locking Flanged Inlet Locking Flanged Outlet 2.39 (60.7) 3.28 (83.3) 3.62 (92.1) 0.75 (19.1) 20 AMP 250V AC/DC / 10 AMP 600V AC 4-Pole 5-Wire Grounding Non-NEMA Ø 2.08 (53.0) Ø 1.84 (46.8) 3.53 (89.7) Ø 1.84 (46.8) Ø 2.08 (53.0) 7314-C Locking Devices NONNEMA NONNEMA devices are no longer UL Listed and are for replacement use only. Add (-G) for grounding version. *Grounding (-G) version not available. For grounding connector, use Cat. No. 7555-G **Uses stainless steel wallplate, Cat. No. 84004-40. 7310-B 2.47 (63.0) NON-NEMA CONFIG. †These 1.13 (28.6) 9965-C CAT. NO. 7582 7567-C* 7565-C* 7556 7557 DESCRIPTION Single Flush Receptacle Locking Plug, Black Nylon Body Locking Connector, Black Nylon Body Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 3520 3521-C 3523-C 3524-C 3525-C NON-NEMA CONFIG. NONNEMA NONNEMA 20 AMP 125V/250V 3-Pole 3-Wire Non-Grounding Non-NEMA†† DESCRIPTION Single Flush Receptacle Locking Plug Locking Connector Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 7310-B 9965-C 7314-C 3325-C 3326-C NON-NEMA CONFIG. X X NONNEMA Y W NONNEMA Y W 20 AMP 3ØY 120V/208V 4-Pole 4-Wire Non-Grounding Non-NEMA†† DESCRIPTION Single Flush Receptacle Locking Plug Locking Connector Locking Flanged Inlet Locking Flanged Outlet CAT. NO. 7410-B 7411-C 7413-C 7408-C 7409-C NON-NEMA CONFIG. NONNEMA W X NONNEMA Z Y W X Z Y Cord Clamp Range ††Effective July 1, 1981, rating for non-grounding versions was changed from 20A-250V AC/DC, 10A-600V AC to comply with Non-NEMA Locking Plugs and Connectors— UL requirements. Add (-G) for grounding devices: (-G) devices are rated 20A-250V AC/DC, 10A-600V AC and are no longer UL Listed — for replacement use only. 15A:.240"–.700" #18–#10 AWG Weather-Resistant Boots for 15A and 20A Locking Plugs and Connectors are listed on page N27 20A 3-Wire:.385"–.780" #16–#10 AWG 20A 4- & 5-Wire:.595"–.895" #14–#10 AWG Wallplates and Covers 302 STAINLESS STEEL 15A SINGLE RECEPTACLE 302 STAINLESS STEEL 20A SINGLE RECEPTACLE WEATHER-RESISTANT FLIP LID COVER FOR 20A INLETS/OUTLETS AND 20A RECEPTACLES 1.41" Dia. Opening 1.60" Dia. Opening IP64 Rated—Includes Gasket and Screws 84004-40 84020-40 WP2 for Inlets/Outlets 7420-CR for Receptacles For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Locking Flush Receptacles • Rugged nylon body and cover for outstanding resistance to impact and harsh chemicals • Double-wipe phosphor-bronze power contacts Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • Most non-NEMA locking devices are not UL Listed and are intended for replacement use only. Consult your Leviton representative for more information on UL Listing for Non-NEMA devices • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94 Operating Temperature: -40°C to 60°C N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 24 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 30 AMP 125/250V, 3ØY120/208V; 50 AMP 250V DC/600V Industrial Grade Non-NEMA Locking Devices 30 AMP 125V/250 3-Pole 3-Wire Non-Grounding Non-NEMA† NON-NEMA CONFIG. X X Y Y W NON-NEMA †Effective July 1, 1981, rating for non-grounding versions was changed from 30A-250V to comply with UL requirements. Add (-G) for grounding devices: (-G) devices are rated 30A-250V and are no longer UL Listed — for replacement use only. 2.38 (60.3) W 3.62 (92.1) CAT. NO. 3330 3331-C 3333-C 3334-C 3335-C 3.28 (83.3) DESCRIPTION Single Flush Receptacle Locking Plug Locking Connector Locking Flanged Inlet Locking Flanged Outlet 1.70 (43.3) 0.75 (19.1) 30 AMP 3ØY 120V/208V 4-Pole 4-Wire Non-Grounding Non-NEMA†† 1.13 (28.6) NON-NEMA CONFIG. 3330 NON-NEMA Ø 1.84 (46.8) ††Effective July 1, 1981, rating for non-grounding versions was changed from 30A-250V AC/DC, 30A-600V AC to comply with UL requirements. Add (-G) for grounding devices: (-G) devices are rated 30A-250V AC/DC, 30A-600V AC and are no longer UL Listed—for replacement use only. 50 AMP 250V DC/600V AC 2-Pole 3-Wire Grounding Non-NEMA U R NON-NEMA CONFIG. GR W G NON-NEMA 50 AMP 250V DC/600V AC 3-Pole 4-Wire Grounding Non-NEMA U R DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet CAT. NO. 7379* 7765-C* 7764-C* 7958* 3331-C GR W G 2.47 (63.0) NON-NEMA CONFIG. X X Z Z Y Y G Ø 1.84 (46.8) CAT. NO. 3771 3763-C 3762-C 3777 3.53 (89.7) G NON-NEMA 3333-C 50 AMP 250V DC/600V AC 3-Pole 4-Wire Grounding Non-NEMA U R DESCRIPTION CAT. NO. NON-NEMA CONFIG. Single Locking Receptacle 3769 Locking Plug 3765-C Locking Connector 3764-C NON-NEMA Locking Flanged Inlet 3775 Weather Resistant Boots for 30A Locking Plugs and Connectors are listed on page N27. Weather Resistant Boots for 50A Locking Plugs and Connectors are listed on page N23. Y Y X GR X Z Z Wallplates and Covers WEATHER-RESISTANT FLIP LID COVER FOR 30A INLETS AND OUTLETS AND 30A RECEPTACLES WEATHER-RESISTANT FLIP LID COVER FOR 50A RECEPTACLES IP64 Rated—Includes Gasket and Screws IP64 Rated—Includes Gasket and Screws WP2 for Inlets/Outlets 7420-CR for Receptacles 7788-CR Yellow Lexan 7770 Gray Metal For complete wallplate selection, see Section E. *For replacement use in existing installations only. SPECIFICATIONS AND FEATURES 30A Locking Flush Receptacles • Rugged nylon body and cover for outstanding resistance to impact and harsh chemicals • Double-wipe phosphor-bronze power contacts 30A Locking Plugs and Connectors • Super tough Nylon body resists damage from severe impact, abrasion and chemicals • Ergonomic, fluted body design with radial grip ridge is ideal for gripping, turning and pulling • Cord clamp does not have to be disassembled from body for wiring—accepts all wire mesh strain reliefs • One-piece, rivetless .035" thick brass connector contacts and solid brass plug blades provide maximum conductivity and long service life 30A Flanged Inlets and Outlets • Rugged nylon flange fits flush and won’t crack in high-abuse applications • Individual deep-funneled chamfered wire wells guide each wire into rectangular chambers • Wire clamps provide positive crimp lock without cutting wire strands 50A Locking Plugs and Connectors • Nylon housing for excellent impact and chemical resistance 50A Locking Receptacles and Flanged Inlets • Heavy-duty Nylon construction for excellent impact and chemical resistance • Clamp-type wire terminals GR Cord Clamp Range Non-NEMA Locking Plugs and Connectors 30A 3-Wire: .385"–.860" #16–#8 AWG 30A 4-Wire: .595"–1.150" #14–#10 AWG 50A 4-Wire: .650"–1.20" #10–#4 AWG Locking Devices DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet Ø 2.08 (52.8) CAT. NO. 3430 3431-C 3433-C 3434-C 3435-C Ø 2.08 (52.8) DESCRIPTION Single Flush Receptacle Locking Plug Locking Connector Locking Flanged Inlet Locking Flanged Outlet TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • Most non-NEMA locking devices are not UL Listed and are intended for replacement use only. Consult your Leviton representative for more information on UL Listing for Non-NEMA devices 50A Devices • UL Listed Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles (File #E-13399) • CSA Certified (File #LR-81290 • NOM certified (#057) MATERIAL CHARACTERISTICS Environmental: Flammability Rated VO per UL94 Operating Temperature: 30A Devices: -40°C to 60°C 50A Devices: -40°C to 75°C For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 N 25 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 50 AMP 125V, 250V, 125/250V, 480V and 3Ø 480V Ø 1.99 (50.5) Ø 2.38 (60.5) Industrial Grade “California Style” CS Non-NEMA Locking Devices CS63-60C DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet Ø 3.50 (88.9) 50 AMP 250V 2-Pole 3-Wire Grounding Non-NEMA U R 4.97 (126.2) Ø 2.12 (53.8) CAT. NO. CS82-69 CS82-65C CS82-64C CS82-75 NON-NEMA CONFIG. NON-NEMA NON-NEMA CONFIG. NON-NEMA 2.54 (64.5) 50 AMP 125/250V 3-Pole 4-Wire Grounding Non-NEMA U R DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet CS63-77 CAT. NO. CS63-69 CS63-65C CS63-64C CS63-75 NON-NEMA CONFIG. Y Y X G X G W W NON-NEMA 50 AMP 3Ø 250V AC 3-Pole 4-Wire Grounding Non-NEMA U R 2.12 (53.8) 0.63 (16.0) DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet Ø 1.98 (50.3) 3.28 (83.3) CAT. NO. CS63-70 CS63-61C CS63-60C CS63-77 DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet Ø 2.24 (56.9) Locking Devices 50 AMP 125V 2-Pole 3-Wire Grounding Non-NEMA U R CAT. NO. CS83-69 CS83-65C CS83-64C CS83-75 NON-NEMA CONFIG. Y Y X G X Z G Z NON-NEMA 50 AMP 480V 2-Pole 3-Wire Grounding Non-NEMA U R 0.89 (22.6) CS83-69 DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet CAT. NO. CS84-69 CS84-65C CS84-64C CS84-75 NON-NEMA CONFIG. Y Y X X G G NON-NEMA 50 AMP 3Ø 480V AC 3-Pole 4-Wire Grounding Non-NEMA U R SPECIFICATIONS AND FEATURES 50A CS Locking Plugs and Connectors • Nylon housing for excellent impact resistance and secure gripping • Color-coded wire entrance holes for simple, easy wiring 50A CS Locking Receptacles and Flanged Inlets • Heavy-duty nylon construction for excellent impact and chemical resistance • Clamp-type wire terminals TESTING AND CODE COMPLIANCE • UL Listed Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles (File #E-13399) • CSA Certified (File #LR-15105) DESCRIPTION Single Locking Receptacle Locking Plug Locking Connector Locking Flanged Inlet CAT. NO. CS81-69 CS81-65C CS81-64C CS8175 NON-NEMA CONFIG. Y Y X X Z Z NON-NEMA Weather Resistant Boots for 50A Locking Plugs and Connectors are listed on page N23 Cord Clamp Range—50A CS Locking Plugs and Connectors: .680"–1.125" #10–#4 AWG Wallplates and Covers WEATHER-RESISTANT FLIP LID COVER FOR 50A RECEPTACLES IP64 Rated—Includes Gasket and Screws • NOM Certified (#057) MATERIAL CHARACTERISTICS Environmental: Flammability Rated VO per UL94 Operating Temperature: -40°C to 75°C 7788-CR Yellow Lexan 7770 Gray Metal For complete wallplate selection, see Section E. N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 26 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com WEATHER-RESISTANT BOOTS Industrial Grade Locking Devices Ø 2.00 (50.8) Locking Plug and Connector Boots—Thermoplastic Elastomer Construction Boots for 15 AMP Industrial Locking Plugs and Connectors DESCRIPTION Locking Plug Boot, Black Locking Plug Boot, High-Visibility Yellow Locking Connector Boot, Black Locking Connector Boot, High Visibility Yellow CAT. NO. 6017-L 6017-LY 6018-L 6018-LY 2.73 (69.4) 6017-LY DESCRIPTION 3-wire Locking Plug Boot, Black 3-wire Locking Plug Boot, High Visibility Yellow 3-wire Locking Connector Boot, Black 3-wire Locking Connector Boot, High Visibility Yellow CAT. NO. 6031 6031-Y 6032 6032-Y Ø 2.81 (71.4) Boots for 3-Wire 20 AMP & 30 AMP Industrial Locking Plugs and Connectors 4.92 (125.0) Boots for 4 and 5-Wire 20 AMP & 30 AMP Industrial Locking Plugs and Connectors 6032 CAT. NO. 6033 6033-Y 6034 6034-Y Ø 2.00 (50.8) DESCRIPTION 4 & 5-wire Locking Plug Boot, black 4 & 5-wire Locking Plug Boot, High Visibility Yellow 4 & 5-wire Locking Connector Boot, black 4 & 5-wire Locking Connector Boot, High Visibility Yellow For Weather-Resistant Boots for 50A Locking Plugs and Connectors see page N23 2.73 (69.4) Ø 2.96 (71.1) 5.15 (131.0) 6034 SPECIFICATIONS AND FEATURES • Feature a triple seal action to protect straight blade and locking plugs and connectors against dirt and moisture in harsh applications • Plug and connector boots available in black and high-visibility yellow • Fluted surface and grip-ring design provide a non-slip grip even in wet conditions Locking Devices 6033 WARRANTY • Backed by a Limited Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability, Rated HB Operating Temperature: -40°C to 90°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 27 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 20 AMP 125V and 30A-600VAC / 20 AMP-250V DC Industrial Grade Locking Power Interrupting Devices—Non-NEMA 3.28 (83.3) 2.50 (63.5) 20 AMP 125V 2-Pole 3-Wire Grounding U R 1.66 (42.2) 23000-HG DESCRIPTION Single Flush Receptacle with a Thermoset body Locking Connector Locking Plug CAT. NO. 23000-HG* 23001-HG* 23004-HG* NON-NEMA CONFIG. W W GR GR B B RECEPTACLE *UL listed for “HOSPITAL USE ONLY” applications in non-hazardous locations 20 AMP 125V 2-Pole 3-Wire Grounding U DESCRIPTION Single Flush Receptacle Locking Connector Locking Plug CAT. NO. 23030 23031-A 23034-A NON-NEMA CONFIG. W W GR GR B B RECEPTACLE 30A-600VAC / 20AMP – 250V DC 3-Pole 4-Wire Grounding U DESCRIPTION Single Flush Receptacle Locking Connector Locking Plug CAT. NO. 20403 21414-B 21415-B NON-NEMA CONFIG. X X GR Y GR Y Z RECEPTACLE Locking Devices 30A-600VAC / 20AMP – 250V DC 4-Pole 5-Wire Grounding U DESCRIPTION Single Receptacle with Fiberglass Reinforced Nylon Interior with Cast Iron and Steel Shell. Fits FS or FD boxes Locking Connector Locking Plug CAT. NO. 25403 NON-NEMA CONFIG. Z Z Y 25414-B 25415-B W X Y EQ GR W Q GR X RECEPTACLE For complete wallplate selection, see Section E. N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 28 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com 15 AMP 125V and 125/250V Industrial Grade Midget Locking Devices 15 AMP 125V 2-Pole 2-Wire Non-Grounding U R NEMA CONFIG. W W Ø 1.07 (27.1) CAT. NO. ML1-P ML1-AP ML1-C ML1-AC ML1-PB ML1-PER Ø 0.96 (24.5) DESCRIPTION Midget Locking Plug Angle Plug Midget Locking Connector Angle Connector Plastic Midget Locking Flanged Inlet Plastic Midget Locking Flanged Outlet NEMA ML1 1.69 (42.9) 15 AMP 125V 2-Pole 3-Wire Grounding U R CAT. NO. ML2-P ML2-AP ML2-C ML2-AC ML2-PB ML2-PER NEMA CONFIG. Ø 0.96 (24.5) W G G NEMA ML2 15 AMP 125/250V 3-Pole 3-Wire Non-Grounding U R CAT. NO. ML3-P ML3-AP ML3-C ML3-AC ML3-PB ML3-PER NEMA CONFIG. Ø 1.11 (28.2) X X ML1-AP W W Y Y NEMA ML3 Straight Blade 15 AMP 125V 2-Pole 2-Wire Non-Grounding U R DESCRIPTION Midget Straight Blade Plug Black & White Nylon CAT. NO. PLUG MS2-P CAT. NO. ANGLE PLUG MS2-AP NEMA CONFIG. NEMA 1-15P W Cord Clamp Range Midget Locking/St. Blade Plugs and Connectors—.218"–.430" #18–#14 AWG SPECIFICATIONS AND FEATURES • Offer a smaller form factor for limited-space applications • Locking Plugs and Connectors feature heavy-duty construction for top performance in the environmental extremes of grueling industrial settings • Flanged Inlets and Outlets are built to endure hard use with rugged nylon flanges that assure a smooth, flush fit and outstanding resistance to cracking and breaking Locking Devices DESCRIPTION Midget Locking Plug Angle Plug Midget Locking Connector Angle Connector Plastic Midget Locking Flanged Inlet Plastic Midget Locking Flanged Outlet 0.96 (24.5) W 1.63 (41.3) DESCRIPTION Midget Locking Plug Angle Plug Midget Locking Connector Angle Connector Plastic Midget Locking Flanged Inlet Plastic Midget Locking Flanged Outlet ML1-P TESTING AND CODE COMPLIANCE • All receptacles, plugs, connectors, inlets and outlets are designed to meet NEMA WD-6, and ANSI C-73, and to meet/exceed UL 498 standards • UL Fed. Spec. Listed WC-596 – Plugs, Connectors and Flanged Inlets (File #E-13393), Receptacles and Flanged Outlets (File #E-13399) • CSA Certified (File No. LR-406) • NOM Certified (#057) • Backed by a Lifetime Warranty MATERIAL CHARACTERISTICS Environmental: Flammability Rated V2 per UL94 Operating Temperature: -40°C to 60°C N For answers to technical questions, call Leviton’s Techline at 1-800-824-3005 29 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com COMBINATION LOCKING & STRAIGHT BLADE • INTEGRATED INLETS & OUTLETS Industrial Grade Locking Devices Combination Locking and Straight Blade Duplex Receptacle 15 AMP 125V 2-Pole 3-Wire Grounding Back and Side Wired U R DESCRIPTION Duplex Combination Locking & Straight Blade Receptacle with Common Feed Duplex Combination Locking & Straight Blade Receptacle with 2 Hot Feeds, 1 Neutral Return Duplex Combination Locking & Straight Blade Receptacle with Split Feed — 2 Hot Feeds, 2 Neutral Returns 2.77 (70.4) 3.28 (83.3) 4.06 (103.2) 1.44 (36.4) CAT. NO. 4792 NEMA CONFIG. W L5-15R G 4794-1R G 4795-2R 5-15R W Integrated Power Inlets and Outlets with Weather-Resistant Covers • • 0.97 (24.7) Engineered to IP 64 and NEMA 3R Protection Ratings Suitable for Industrial Indoor and Outdoor Use Integrated Power Inlets and Outlets with Weather-Resistant Covers U R 4792 Gray, Glass-Filled Thermoplastic Cover and White, Nylon Device DESCRIPTION Standard Wire Wells, 15A-125V 2-Pole, 3-Wire CAT. NO. FLANGED INLET 4716-CWP CAT. NO. FLANGED OUTLET 4715-CWP W W NEMA L5-15P NEMA L5-15R Slots for Fork Terminals, 15A-125V 2-Pole, 3-Wire 4716-FWP G 4715-FWP W NEMA L5-15P W NEMA L5-15R G Standard Wire Wells, 15A-250V 2-Pole, 3-Wire 4586-CWP G 4585-CWP X NEMA L6-15P X G NEMA L6-15R G Y Y 1.88 (46.6) 2.84 (72.2) Note: For straight blade configurations, please see page M7. 4715-FWP 3.25 (82.6) Wallplates 1.88. (46.6) 2.84 (72.2) 4716-FWP 4.56 (115.9) Locking Devices 3.25 (82.6) 4.56 (115.9) G 302 STAINLESS STEEL DUPLEX RECEPTACLE THERMOPLASTIC DUPLEX RECEPTACLE 84003-40 80703-E For complete wallplate selection, see Section E. SPECIFICATIONS AND FEATURES Combination Devices • Impact-resistant black thermoplastic nylon face and body • Smooth face does not collect dirt • Large, triple-wipe brass “T” contacts for superior contact and conductivity • Triple-combination terminal screws • Back and side wire options accept #10–#14 AWG stranded or solid wire Integrated Devices • Glass-filled thermoplastic cover and plate provide outstanding impact resistance and durability • Dual gaskets, one under plate and one under lid, for weather-resistant fit • Stainless steel external hardware resists corrosive effects of moisture • Large thumb-tab makes it easy to open cover with gloved hand • Mounts to panels or FS/FD boxes • UL Listed and CSA Certified for wet locations with cover closed TESTING AND CODE COMPLIANCE Combination Devices • UL Listed (File #E-13393) • CSA Certified (File #LR-406) • NOM Certified (#057) • Backed by a Limited 10-Year Warranty Integrated Devices • UL Listed (File #E-13397) • CSA Certified (File #LR-16347) • NOM Certified (#057) • IP 64 Suitability Rating (protected against dust and splashing water) • NEMA Type 3R Enclosure Rating when properly installed (protected against rain, sleet and damage from external ice formations) • Backed by a Limited 2-Year Warranty MATERIAL CHARACTERISTICS Combination Devices Environmental: Flammability, Rated V2 Operating Temperature: -40°C (without impact) to 60°C maximum continuous Integrated Devices Environmental: VO Flammability Rating per UL 94 Operating Temperature: -40°C to 60°C N To learn more about Leviton’s outstanding offering of devices visit our Website at: www.leviton.com 30 Courtesy of Steven Engineering, Inc. ● 230 Ryan Way, South San Francisco, CA 94080-6370 ● General Inquiries: (800) 670-4183 ● www.stevenengineering.com