Fieldbus Connectivity busstop® Overview Connector Specifications Pre-molded Fieldbus Cables Part Number Keys 2 7 8 9 1 FOUNDATION™ Fieldbus Overview Cable and Cordsets Junctions (Bricks) Device Glands Terminating Resistors Tees and Adapters Surge Suppressor, Power Conditioner and Lokfast™ Guard Receptacles Field Wireables and Accessories 13 18 24 32 34 35 39 42 44 2 PROFIBUS®-PA Overview Cable and Cordsets Junctions (Bricks) Device Glands Terminating Resistors Tees and Adapters Surge Suppressor and Lokfast™ Guard Receptacles Field Wireables and Accessories 47 52 56 62 63 65 69 71 73 3 HART® Overview Cable and Cordsets Junctions Device Glands Tees and Adapters Receptacles Field Wireables and Accessories 76 80 86 90 91 95 98 4 Installations 102 5 Index of Components 120 6 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 1 AW orldwide Fieldbus Solution Worldwide Interlink BT® - A Banner -TURCK Bus Pr oducts Company InterlinkBT Banner-TURCK Products InterlinkBT® is a joint venture between two renowned sensor companies, TURCK, Inc. and Banner Engineering, to focus specifically on bus products. The experience and advanced bus technologies of these companies are now combined, resulting in the industry’s broadest, most complete line of stations, junctions, cordsets and components for device-level networks. InterlinkBT® is the industry’s bus I/O specialist and leading supplier of top-quality bus products. Most importantly, InterlinkBT® is your best solution to connect input/output devices to open buses. Interlink BT InterlinkBT BT’’S Fieldbus Connectivity Catalog This catalog covers high quality on-the-machine and at-the-process FOUNDATION™ fieldbus H1, PROFIBUS®-PA and HART® interconnect products. The product offering emphasizes materials for diverse applications where aggressive environments are often the norm. Cable InterlinkBT® has the products for interconnecting all your devices on a network segment. By simply plugging components together these products allow for quick installations of new plant layouts and easy alterations to existing installations. InterlinkBT’s junction blocks are rugged and can be mounted in aggressive environments. Spur or drop count can vary from 4 to 8 with the choice of minifast® or eurofast® connector sizes. InterlinkBT® cable exceeds ISA SP50.02 specifications for impedance and attenuation. Pre-molded cordsets are available with either minifast® or eurofast® connector sizes. The easy-to-use terminating resistor simply screws into the end of the Home Run cable. You can reliably use InterlinkBT® fieldbus products in the harshest of environments. 2 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Connectors 1 Not all the I/O in a fieldbus system can be connectorized, but when it can it is extremely effective. A few minutes of layout and bill-of-material planning can replace hours of costly wire installation. In addition, product replacement is greatly facilitated by using industrial grade quick disconnect plug-and-play receptacles. InterlinkBT® uses two industrial standardized connectors. The generic names for them are “Mini” and “Micro” or “Euro”. In one variation or another these two standardized connectors are produced by the thousands. Rough estimates put the “Mini” style at over 10,000 per day and the “Euro” at over 25,000 per day. They are used in every industry that requires rugged economic plug-and-play connectorization. Both were standardized by DIN (German Industrial Standards) in their early design. Today they are recognized standards throughout the world. The sheer volume means that the build processes for these two standards are understood, tooled, automated and economical. The volume and breadth of applications means that broad selections of off-the-shelf products are available. There are three materials for coupling nuts; stainless steel, nylon and nickel-plated brass. The mating pin and sleeves are gold-plated brass. The body is made of polyurethane and is injection molded to the cable jacket to provide strain relief and to seal the connections from the atmosphere. The Mini’s pin and sleeve are rated at 9 amps and the Micro is rated at 4 amps. The designated ground pin of the Mini family is longer than the other pins, resulting in a make-first/break-last ground. This feature is not explicitly required for IS or NI applications, but is a sound engineering choice. All the pins of the Euro make and break at the same time during insertion and removal. Junction Boxes The junction boxes shown in this catalog are passive hubs. Although no conditioning or monitoring takes place, some junctions have short circuit protection. This protects the power on the trunk and allows use in Class 1, Div 2 locations. The boxes are made from two different materials; copper-free die-cast aluminum with a powder coated enamel finish or polyurethane overmold. Both housings are available with either 316 stainless steel or nickel plated brass connectors. The junction boxes are rated NEMA 1, 3, 4, 4X, 12, 13 and IEC IP67. These ratings are conditional, requiring the cordset or cap to be installed. Although the die cast housing is rated 4X (salt-water spray test) we highly recommend the polyurethane or fiberglass housing for aggressive environments. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3 Occupants on the Bus Active Hub - a multiple port repeater or amplifier that lengthens the branching ability of a bus. Barrier Box - limits current/voltage to an area. Brick - fully connectorized passive junction. Bridge - there are two types; one is a double-sided node that connects two segments together that are the same protocol but different transmission speeds, the other is a smart repeater that only repeats the data between two bus segments when the source and destination address are in different segments. The bridge must be programmed to know what the addresses are and their respective segments. Bus Junction - generic name for a passive hub. Busline - any group of wires that carries data from node-to-node. Dr opline - a reduced branch (spur) from a trunkline. Dropline Gateway - a special node on two different buses that serves as a signal and data translator between the buses. LAS (Link Active Scheduler) - controls communication on the bus. Creates a token circulation list (Live List) that defines access on the bus. Devices may only communicate when given access by the LAS unit. Multiple devices may have LAS capabilities but only one can communicate at a time. Node - an addressable device on the bus. Power Conditioner - device used to condition the power to be for a bus segment. Allows power and data to exist on the same wires. Repeater - a product that strengthens a signal, while adding up to a half-bit wait state and producing a fresh signal without distortions. It also links two portions of the same bus together. A repeater is used when a signal is weak or distorted. Router - a higher level bridge for connection of wide area networks. Simple Device - anything that does not have LAS capabilities. Tee System T ee - a field wireable tee. Tee - a product that creates a branch or drop from a bus. esistor - a resistor that is put at the beginning and end of the main busline to stabilize and minimize Terminating rresistor reflections. Trunk line - the main busline. To Control Highway Fieldbus I/O Host 24V 24V Main Trunk Cable Main Trunk Cable Terminator Spurs BRPS-49-M213 JTBS-49SC-M633 Pressure Transmitter 4 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Bus T opology Topology Topology is a term that applies to buses. It describes how the data lines connect the nodes together. The first bus goes back to the original telegraph - two data lines hanging on wooden poles going from telegraph station to telegraph station. 1 Bus - the simple straight-line topology is called a bus. Another term used is “Daisy Chain”, where the trunk simply runs from device to device. Branch - a common bus can have branches, and sometimes the branches can have branches. Another term used to describe the branches is “drops” or “spurs”, as in FOUNDATION™ fieldbus. Depending on the bus the branches may be restricted to just a few centimeters or a free-form topology with restrictions only on the cumulative distance of all data lines. Star - the bus lines radiate from a single point. A junction (either passive or active) looks like a star. FOUNDATION™ fieldbus also refers to this as a “chicken foot” topology with many branches connected in a relatively small area. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 5 Bus T ypes Types There are several different bus types utilizing the following technologies: Client / Server - upload/download information, setpoint changes, alarm management, remote diagnostics and one to one communications. Media Access - this is the “right-of-way” for talking on the bus. There are three main types: Master Control - one super node controls all transmission, sequence and time. Remaining nodes do not talk unless told to by the master. Token Passing - this is a message shift method that is incremented in a manner that allows each node a chance to talk during each cycle. CSMA - an access method allowing each node to speak, provided that it has something to say and no other node is talking on the line. Message Collision A voidance - when two people talk simultaneously there is a verbal collision. A few humans can Avoidance talk and listen to someone else at the same time but nodes cannot. Both token passing and master control do not have that problem. A field node can only access the bus when it is its turn to talk or when it has been told to talk. CSMA-type buses do have this problem. The problem goes away when they are operated as a master-to-slave. When operating in the native CSMA access method two nodes could start talking simultaneously. Two major ways have been developed to handle a potential collision: CD - collision detection - all senders must also be receivers. If two nodes start talking at the same time they will hear a collision. Both stop talking, wait a random length of time, then look for a clear line to start talking again. BA - bitwise arbitration - all senders must also be receivers. The busline must be of a specific length or less so that all nodes hear the bit at the same time (actually the first node and the last node can be approximately 1/6 bit apart). Messaging - there are three major types in the run mode, but many more during start-up and initialization. Solicited - a response to another node or a response when it is the node’s predetermined time to speak (token passing). Unsolicited - a response to a change-of-state at the node. Explicit - a command order. It may command an output be turned “On” or “Off”. It may command any node to report its diagnostic status or identity itself in full detail. One last distinction must be made for the output nodes. How do they get the information so they know what to do? Although there is an overlap with the terms used for messaging, there are important differences: Explicit Message - this is a command from another node. Limited Peer -to-Peer - exclusive one-to-one relationship between the input node and the output node. This could Peer-to-Peer also be called exclusive peer-to-peer. Unlimited Peer -to-Peer - similar to limited peer-to-peer, but the output node may get information from several input Peer-to-Peer nodes. Publisher / Subscriber - scheduled distribution of data to nodes on the subscriber list. 6 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Connector Specifications minifast® Connector - 7/8” - 16UNF thread -100% electrically tested -Meets: SAE H1738-2 -Current Rating: 9A -Voltage Rating: 300V -Protection: NEMA 1,3,4,6P IEC IP67 -NEMA 4X with stainless steel coupling nuts -Temperature: -30ºC to +85ºC -Oscillation: 65mm (2.5in.) to 125mm (5in.) -Pull Strength: 100 lbs - 5 to 12.5 cycles/sec. for 2 million cycles eurofast® Connector -M12 x 1 thread -100% electrically tested -Meets: IEC 61076 -Current Rating: 4A -Voltage Rating: 300V -Protection: NEMA 1,3,4,6P and IEC IP67 -NEMA 4X with stainless steel coupling nuts -Temperature: -30ºC to +85ºC -Vibration: 10 to 500 Hz and 0/35mm or 5g -Pull Strength: 50 lbs 1 multifast® Connector - M23 x 1 thread -100% electrically tested -Current Rating: 4A -Voltage Rating: 300V -Protection: NEMA 1,3,4,6P IEC IP67 -Temperature: -30ºC to +85ºC InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 7 Pr e-molded Fieldbus Cables Pre-molded Pre-molded fieldbus cables ensure simple and secure wiring of the connected fieldbus components. Time-consuming wiring of individual components and bus communication problems due to wiring errors or incomplete shielding are eliminated. Molded polyurethane insulation provides IP67 protection. Standard lengths of pre-molded cordsets and bulk cable are listed below. Consult the factory for other lengths. Standar d Cable Lengths Standard Cordsets Bulk Cable meters feet 0.3 1.0 0.5 1.6 1.0 3.3 1.5 4.9 2.0 6.6 2.5 8.2 3.0 9.8 4.0 13 5.0 16 6.0 20 8.0 26 10 33 15 49 20 66 25 82 30 98 40 131 50 164 meters feet 30 98 75 246 150 492 225 738 300 984 --- --- Other lengths available upon request. Unit Conversions: 1 meter = 3.28 feet 1 meter = 39.79 inches 8 Tolerances: +50/-0 mm or +4% of length which ever is greater InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 eurofast® Part Number Keys Cor dsets Cordsets R S C 49x V 1 *M Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8) Consult factory for other lengths R = Straight W = Right Angle Gender S = Male Connector K = Female Connector Cable T ype (x) Type 48x (see page 51) 49x (see page 17) H4x (see page 79) Designator for eurofast® Coupling Nut Material V = Stainless Steel (Blank) = Nickel-Plated Brass Receptacles F Designator for eurofast® Gender S = Male Connector K = Female Connector S F V 49x *M Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8) Consult factory for other lengths Cable T ype (x) Type 48x (see page 51) 49x (see page 17) H4x (see page 79) Designator for Receptacles Coupling Nut Material V = Stainless Steel (Blank) = Nickel-Plated Brass InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 9 minifast® Part Number Keys Cor dsets Cordsets W K 4 9x M *M Length in Meters (*) Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8) Consult factory for other lengths R = Straight W = Right Angle Gender S = Male Connector K = Female Connector Cable T ype (x) Type 48x (see page 51) 49x (see page 17) H4x (see page 79) Coupling Nut Material M = Nickel-Plated Brass V = Stainless Steel (Blank) = PA 6.6 (Nylon) Receptacles R K F V 4 9x *M Length in Meters (*) R = Straight Gender S = Male Connector K = Female Connector Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8) Consult factory for other lengths Cable T ype (x) Type 48x (see page 51) 49x (see page 17) H4x (see page 79) Designator for Receptacles Coupling Nut Material V P 10 = Stainless Steel = Nickel-Plated Brass InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Junction T ee Part Number Key Tee JT B S 49 SC M 6 3 3 1 Connector Material 3 = Stainless Steel 4 = Nickel-Plated Brass Housing 1 = Aluminum (JBBS only) 2 = Fiberglass (JBBS only) 3 = Polyurethane (JTBS only) 4 = Hytrel (JTBS only) JT = Junction Tee JB = Junction Box Number of Ports 4 = 4 ports 6 = 6 ports 8 = 8 ports Bus System 48 = PROFIBUS®-PA 49 = FOUNDATION™ fieldbus Connector T ype Type ® minifast M = ® eurofast E = Pr otection Protection SC = Short Circuit (Blank) = None InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 11 For HART® Systems Only H AR T ® Junction Box Part Number Key ART V B Housing VBM - Metal Housing eurofast® Connectors 4MB12 - Nylon Housing or eurofast® Connectors 8MB12 JTBS - Polyurethane Housing minifast® Connectors Number of Ports 40 - 4 ports 60 - 6 ports 70 - 7 ports 80 - 8 ports 12 M 4 0 H C S V 1 2 Home Run Connector CS12 - multifast® 12-pin CSV12* - multifast® 12-pin CSV19* - multifast® 19-pin CS19 - multifast® 19-pin - minifast® 5-pin RS RSV* - minifast® 5-pin with *stainless steel coupling nut HAR T® T opology ART Topology H - HART® Point-to-Point HM - HART® Multidrop InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 1 FOUNDA TION™ fieldbus Cables and Accessories OUNDATION 2 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 13 FOUNDA TION™ fieldbus Overview OUNDATION FOUNDATION™ fieldbus is a communication protocol and defined physical method to interconnect smart devices such as temperature transmitters, pressure transmitters and valve actuators. The physical layer conforms to ISA SP50.02 and IEC 1158-2 standards for fieldbuses. In comparison to 4-20 mA loops that only allow for one device connection per twisted pair, fieldbus technology enables many smart devices to share one communication medium. The digital communication signal is superimposed onto a DC carrier. This greatly reduces the amount of terminations needed to connect all the field devices to a host system. It also allows greater flexibility for future additions of I/O points. A FOUNDATION™ fieldbus device is addressable and has capabilities to store and transmit data. The devices can store values, track changes and use pre-set alarms to trigger. Based on pre-defined tag names, host systems can read transmitter values such as temperature and pressure or set values of a valve actuator. The digital signal encoding is done using Manchester BiPhase-L and error checking is done with the CRC method. FOUNDATION™ fieldbus has two types of devices; a Basic Device (BD) and a Link Active Scheduler (LAS). A Basic Device is designed to read inputs, track values and set outputs if programmed to do so. A LAS device performs the same features as a BD, however it goes one step further by handling network communication timing between all the active devices on the network. The LAS essentially creates a time table so that all devices can get a chance to transmit/receive data on the bandwidth. A fieldbus segment can have many Basic Devices but must have at least one Link Active Scheduler. At least two LAS devices are recommended on the network to provide redundancy. If there is more than one LAS on the network, the one that powers-up first gets the LAS designation and the other LAS unit switches to BD mode of operation. General Layout T opologies Topologies e 1 for an example. All transmitters In essence, all devices on a fieldbus segment are connected in parallel. See Figur Figure connected to the fieldbus segment listen to all communication signals, however the protocol determines the rules as to which devices respond to the messages. For the purpose of this guide only the physical layout will be discussed in detail. The general layout is either a star (chicken foot) or daisy chain. 93.3FM 1 2 3 4 5 Figure11- Parallel WiringDiagram Diagram Figure Parallel Wiring Communication Signal The FOUNDATION™ fieldbus H1 communication signal is a square waveform superimposed on a DC carrier. The frequency of the signal is 31.25Khz. Although they do not have to, most devices derive their supply power from the fieldbus communications cable. The fieldbus specification states that devices must not be polarity sensitive. It is good electrical practice though to have all devices wired with the same polarities. The voltage range allowed for proper operation is 9-32 VDC. A typical fieldbus device will consume 20 mA of current. 14 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Star T opology Method Topology A star topology has a central connection point for all terminations. This layout works well when there are many devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the fieldbus segment. The best design would be to connect them all to a junction brick and then run a home run cable e 2 for a pictorial example. from the junction brick back to the control room. See Figur Figure The Home Run cable is considered the main trunk line for communication. Each device that is connected to the junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line. 2 Figure 2 - Star Topology Example Daisy Chain Configuration In a daisy chain configuration each device would require a tee so that the Home Run cable would be able to go to each device. From a design standpoint, the Daisy Chain method is easiest to do when the exact cable tracks are e 3 for an known. Pre-made cordsets can then be purchased, making the network easy to assemble. See Figur Figure example drawing. A fieldbus transmitter is connected to each of the tanks in the field. The Home Run cable essentially is routed to each device in series. Transmitters Figure 3 - Daisy Chain Layout In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. The key to the wiring design is to make layouts valid per the fieldbus specifications. One of the benefits to fieldbus is reduced wiring of devices, leading to faster start-up times. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 15 Fieldbus Cable Specifications The specifications for fieldbus H1 physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2 Physical Layer Standards. The same standard is also listed in the FOUNDATION™ fieldbus specifications under 31.25 Kbps Physical Layer Profile FF-816-1.4. There are essentially four types of cable designations for fieldbus. Type A cable is the most preferred for new installations because it allows for the most versatile lengths. The other types of cable are able 1. for installations where cable already exists from 4-20 mA systems. See T Table Type Cable Description Conductor Size Maximum Length Type A Shielded, Twisted Pair # 18 Awg 1900 m (6232 ft) Type B Shielded, Multi Twisted Pair # 22 Awg 1200 m (3936 ft) Type C Unshielded, Multi Twisted Pair # 26 Awg 400 m (1312 ft) Type D Shielded, Untwisted Pair # 16 Awg 200 m (656 ft) Table 1 - Fieldbus Cable Specifications InterlinkBT® offers cables with both two conductors and three conductors, with the third conductor available for a centralized ground of devices if needed. InterlinkBT® cables meet or exceed the specifications of ANSI/ISA-SP50.021992, the fieldbus standard for use in industrial control systems. The maximum spur length is determined by the number of devices in the segment. Cable Trunk 1900 m 16 Number of Devices Maximum Spur Length 25-32 0 m (0 ft) 19-24 30 m (98 ft) 15-18 60 m (197 ft) 13-14 90 m (295 ft) 2-12 120 m (394 ft) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 F OUNDA TION™ fieldbus - Cable Specifications OUNDATION Our cable meets the requirements of ISA/SP50 and FOUNDATION™ fieldbus requirements for Type A cable. Cables are available in 3-wire versions with a device ground or 2-wire versions. 1 2 Cable Specifications Type A Cable - Temperature range: -40 to 105°C (-40 to +221F) 11 - Governed by: ISA SP50.02 specification - Sunlight resistant - PLTC and ITC rated (CSA FT4) - Impedence[Z0 at fr (31.25 kHz)] = 100Ω ± 20% - Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km - Maximum capacitive unbalance to shield = 2 nF/km - Maximum DC resistance (per conductor) = 24 Ω/km - Maximum propagation delay variance 0. 25 fr to 1.25 fr = 1.7 µs/km - Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG) or 1.2 mm2 (#16 AWG) - Minimum shield coverage shall be 90% Data Pair AWG DCR (/1000 ft) Color Code Insulation Outer Jacket Material Color Nominal O.D. Shields Type Drain Wire 18 AWG Green/Yellow PVC Yellow 7.9mm (.310 in) Foil 20 AWG RB50693-*M 1 6.5 Ohms PE 18 AWG Green/Yellow PVC Blue 7.9mm (.310 in) Foil 20 AWG RB50783-*M 1 NEC ITC PLTC/CM 2/18 AWG CEC[CMG HLBCD] Blue/Brn CEC 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Yellow 12.7mm (0.5 in) Foil 18 AWG RB50874-*M 11 NEC ITC PLTC/CM 2/18 AWG CEC[CMG HLBCD] Blue/Brn CEC 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Blue 12.7mm (0.5 in) Foil 18 AWG RB50803-*M 11 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Yellow 7.9mm (.310 in) Foil/Braid 20 AWG RB50784-*M 1 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Blue 7.9mm (.310 in) Foil/Braid 20 AWG RB50786-*M 1 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Orange 7.9mm (.310 in.) Foil/TC Braid 20 AWG RB50785-*M 1 NEC ITC PLTC CEC [CMG] 2/16 AWG Blue/Brn 4.3 Ohms PE None PVC Yellow 8.5mm (.335 in.) Foil 20 AWG RB50891-*M 1 Type Approvals 490 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 105°C 300V 490B 105°C 300V 492A 105°C 300V 492BA 105°C 300V 493 105°C 300V 493B 105°C 300V 493O 105°C 300V 496 105°C 300V Device Ground AWG Color Code Bulk Cable Ref. Part No. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 17 F OUNDA dsets TION™ fieldbus - Cable and Cor Cordsets OUNDATION Pin (Male) www.interlinkbt.com eurofast® minifast® † Try Cordset Builder Online! RSV WSV Pin (Male) Socket (Female) RKV RSCV WKV RSV 49x -*M WSV 49x -*M RKV 49x -*M WKV 49x -*M RSCV 49x -*M RSV RSV 49x -*M RSV WSV 49x -*M RSV RKV 49x -*M RSV WKV 49x -*M RSV RSCV 49x -*M WSV WSV 49x -*M WSV RKV 49x -*M WSV WKV 49x -*M WSV RSCV 49x -*M RKV RKV 49x -*M RKV WKV 49x -*M RKV RSCV 49x -*M WKV WKV 49x -*M WKV RSCV 49x -*M Pin (Male) RSV WSV Socket (Female) minifast® † Bare RKV × * † Pin (Male) RSCV RSCV 49x -*M RSCV WSCV Socket (Female) eurofast® WKV RKCV WKCV Indicates cable type. Indicates length in meters. Consult factory for availability of armorfast® with eurofast® connectors. armorfast® cable only - straight only. For nickel-plated brass coupling nut: RSV...to RSM... RSCV...to RSC... Bulk cable, see page 8 for standard lengths. Example 18 WSV RSCV 490-1M 1 METER InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 FOUNDA dsets TION™ fieldbus - Cable and Cor OUNDATION Cordsets eurofast® Pin (Male) WSCV minifast® Socket (Female) RKCV WKCV Pin (Male) RSFPV Socket (Female) RKFPV eurofast® bulkhead Pin (Male) FSFDV Socket (Female) 2 FKFDV WSCV 49x -*M RKCV 49x -*M WKCV 49x -*M RSFPV 49x -*M RKFPV 49x -*M FSFDV 49x -*M FKFDV 49x -*M RSV WSCV 49x -*M RSV RKCV 49x -*M RSV WKCV 49x -*M RSV RSFPV 49x -*M RSV RKFPV 49x -*M RSV FSFDV 49x -*M RSV FKFDV 49x -*M WSV WSCV 49x -*M WSV RKCV 49x -*M WSV WKCV 49x -*M WSV RSFPV 49x -*M WSV RKFPV 49x -*M WSV FSFDV 49x -*M WSV FKFDV 49x -*M RKV WSCV 49x -*M RKV RKCV 49x -*M RKV WKCV 49x -*M RKV RSFPV 49x -*M RKV RKFPV 49x -*M RKV FSFDV 49x -*M RKV FKFDV 49x -*M WKV WSCV 49x -*M WKV RKCV 49x -*M WKV WKCV 49x -*M WKV RSFPV 49x -*M WKV RKFPV 49x -*M WKV FSFDV 49x -*M WKV FKFDV 49x -*M RSCV WSCV 49x -*M RSCV RKCV 49x -*M RSCV WKCV 49x -*M × RSCV RSFPV 49x -*M RSCV RKFPV 49x -*M RSCV FSFDV 49x -*M RSCV FKFDV 49x -*M WSCV WSCV 49x -*M WSCV RKCV 49x -*M WSCV WKCV 49x -*M WSCV RSFPV 49x -*M WSCV RKFPV 49x -*M WSCV FSFDV 49x -*M WSCV FKFDV 49x -*M RKCV RKCV 49x -*M RKCV WKCV 49x -*M RKCV RSFPV 49x -*M RKCV RKFPV 49x -*M RKCV FSFDV 49x -*M RKCV FKFDV 49x -*M WKCV WKCV 49x -*M WKCV RSFPV 49x -*M WKCV RKFPV 49x -*M WKCV FSFDV 49x -*M WKCV FKFDV 49x -*M InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 19 minifast® Cor dset and Receptacle Connector Dimensions and Pinouts Cordset RSV -* RSV-* RKV -* RKV-* WKV-* WSV -* WSV-* RSFPV -* RSFPV-* RKFPV -* RKFPV-* Male Mounting Installation Female 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) Pinouts according to CENELEC EN 50 044 numbering convention. Bracket dimensions are in [inches]. 20 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 eurofast® Cor dset and Receptacle Connector Dimensions and Pinouts Cordset RSCV -* RSCV-* RKCV -* RKCV-* 2 WSCV -* WSCV-* WKCV -* WKCV-* FSFDV -* FSFDV-* FKFDV -* FKFDV-* Male Mounting Installation Female 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 21 InterlinkBT offers a full line of connectors approved by DNV and ABS. Marine Cable - Specifications New FOUNDATION™ fieldbus cables that are UL1309 and CSA 222 No. 245 approved. • • • • • • Type 4910 UL1309 4911 UL1309 Approvals Device Ground Data Pair AWG DCR (/1000 ft) AWG Color Code Color Code Insulation Outer Jacket Material Color Nominal O.D. Shield/Armor Type Drain Wire Bulk Cable Part No. IEEE 1202/FT4 2/18 AWG IEEE 45-1998 Blue/Brn IEEE 1580-2001 x 90 6.5 Ohms XL PE 18 AWG Green/Yellow TPE / Black 8.9mm (.350 in) Foil 20 AWG RB51047-*M IEEE 1202/FT4 2/18 AWG IEEE 45-1998 Blue/Brn IEEE 1580-2001 x 90 6.5 Ohms XL PE 18 AWG Green/Yellow TPE / Black 12.7mm (.500 in) TC Braid 20 AWG RB51048-*M Drilling Muds • Water Based • Synthetic Based • Diesel Based • Mineral Oil Based 22 Highly flame retardant, IEEE 1202/FT4 and IEC 332-3 Category A Meets cold bend at -55° C (-67° F) Meets cold impact at -50° C (-58° F) Excellent moisture and oil resistance Excellent cut through and abrasion resistance Sunlight resistant extremelife-130™ cables have been extensively tested in various drilling muds/fluids. The extremelife-130 cables, with their exclusive arcticlife jacket materials, were compared with the industry standard neoprene cables. All tested cables passed the tensile strength and elogation tests. The extremelife-130™ cables proved to be much more stable in size through the tests when compared to the neoprene jacketed cables. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 eurofast® Heavy Duty Cor dsets Cordsets To meet the needs of the most demanding applications, use the heavy duty cordset. The long, heavy coupling nut completely supports the molded plug body to provide superior strength. 2 Extensive field and lab testing of the RKG style exceed SAE H1738-2 requirements - right angle pull force tested to over 200 lbs! RSGV -* RSGV-* RKGV -* RKGV-* * For nickel-plated brass coupling nut RSGV... to RSG... RKGV... to RKG... Male Female 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 23 Short Circuit minifast® Junction T ee Tee SC models only Description The FOUNDATION™ fieldbus junction tee is available with short circuit protection and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance. JTBS-49SC-M633 4-Pin Male P1 4-Pin Female S0-S6 Dimensions MOUNTING SCREW 1/4” (2) NOT INCLUDED Short Circuit Protection (only available with SC models) Electrical • Short Circuit Protection: 55mA (Isc) • Voltage Open Circuit: 35VDC • Current Consumption: 5mA Specifications Diagnostic • LED Indication: Green LED - Bus Power; P1 and S0 only Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see InterlinkBT® drawing N1-2.400 T6, Ta = 70°C 24 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Short Circuit Protected Connector Size Connector Material Part Number Number of Ports Overmold Material Quick Selection Guide JTBS-49-M433 4 mini polyurethane stainless steel No JTBS-49-M434 4 mini polyurethane nickel-plated brass No JTBS-49-M633 6 mini polyurethane stainless steel No JTBS-49-M634 6 mini polyurethane nickel-plated brass No JTBS-49SC-M433 4 mini polyurethane stainless steel Yes JTBS-49SC-M434 4 mini polyurethane nickel-plated brass Yes JTBS-49SC-M633 6 mini polyurethane stainless steel Yes JTBS-49SC-M634 6 mini polyurethane nickel-plated brass Yes JTBS-49-E433 4 euro polyurethane stainless steel No JTBS-49-E434 4 euro polyurethane nickel-plated brass No JTBS-49-E633 6 euro polyurethane stainless steel No JTBS-49-E634 6 euro polyurethane nickel-plated brass No JTBS-49SC-E433 4 euro polyurethane stainless steel Yes JTBS-49SC-E434 4 euro polyurethane nickel-plated brass Yes JTBS-49SC-E633 6 euro polyurethane stainless steel Yes JTBS-49SC-E634 6 euro polyurethane nickel-plated brass Yes JTBS-49SC-IE433 4 idc polyurethane stainless steel Yes JTBS-49SC-IM633 6 idc/mini polyurethane nickel-plated brass Yes JTBS-49SC-IE633 6 idc/euro polyurethane stainless steel Yes JTBS-49SC-IM433 4 idc/mini nickel-plated brass Yes polyurethane InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 2 25 Fieldwireable Junction T ee Tee JTBS-49SC-I633 Description JTBS-49SC-IM633 JTBS-49SC-IE633 The FOUNDATION™ fieldbus fieldwireable junction tee is available with short circuit protection and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance. JTBS-49SC-I633 MOUNTING SCREW 1/4” (2) NOT INCLUDED Dimensions Electrical • Short Circuit Protection: 55mA (Isc) • Voltage Open Circuit: 35VDC • Current Consumption: 5mA Specifications Diagnostic • LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see InterlinkBT® drawing N1-2.400 T6, Ta = 70°C Pending 26 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable Junction T ee Assembly Wireable Tee Consult factory for availability. 2 Description Includes termination kit for each port. 1. Trim cable jacket 15-20mm 2. Place nut and seal onto cable. Seal should rest on cable jacket 3. Insert conductors in carrier 4. Trim conductors flush 5. Insert keyed carrier into port 6. Tighten back nut Carrier Connector Assembly Seal Nut Termination kit 1. 2. 3. 4. Pinouts Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) Trim Length 15-20mm InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 27 minifast® Passive Multiport Junctions (Bricks) SC models only Description The junction box is available with short circuit protection and is FM Approved for Cl 1, Div 2 hazardous locations. The rugged, fully encapsulated die-cast aluminum enclosure is available with stainless steel connectors. JBBS-49-M813 JBBS-49-M613 JBBS-49-M413* Dimensions / Part Number * JBBS-49SC-M413 overall dimensions 7.3mm X 2.52mm Short Circuit Protection (only available with SC models) Electrical • Short Circuit Protection: 55mA(Isc) • Voltage Open Circuit: 35VDC • Current Consumption: 5mA Applications Diagnostic • LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see InterlinkBT® drawing N1-2.400 T6, Ta = 70 degrees C For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-49-M413 to JBBS-49-M414 For fiberglass housing change part number to -Mx2x. Example: JBBS-49-M613 to JBBS-49-M623 28 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Connector Size Housing Material Short Circuit Protected Part Number Number of Ports Connector Material Quick Selection Guide JBBS-49-M813 8 mini aluminum stainless steel No JBBS-49-M613 6 mini aluminum stainless steel No JBBS-49-M413 4 mini aluminum stainless steel No JBBS-49-M814 8 mini aluminum nickel-plated brass No JBBS-49-M614 6 mini aluminum nickel-plated brass No JBBS-49-M414 4 mini aluminum nickel-plated brass No JBBS-49-M823 8 mini fiberglass stainless steel No JBBS-49-M623 6 mini fiberglass stainless steel No JBBS-49-M423 4 mini fiberglass stainless steel No JBBS-49-M824 8 mini fiberglass nickel-plated brass No JBBS-49-M624 6 mini fiberglass nickel-plated brass No JBBS-49-M424 4 mini fiberglass nickel-plated brass No JBBS-49SC-M813 8 mini aluminum stainless steel Yes JBBS-49SC-M613 6 mini aluminum stainless steel Yes JBBS-49SC-M413 4 mini aluminum stainless steel Yes InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 2 29 eurofast® Passive Multiport Junctions (Bricks) SC models only Description Rugged, fully encapsulated die-cast aluminum brick with eurofast® connectors. JBBS-49-E813 JBBS-49-E613 JBBS-49-E413* Dimensions / Part Number * JBBS-49SC-E413 overall dimensions 7.3mm X 2.52mm Short Circuit Protection (only available with SC models) Applications Electrical Short Circuit Protection: 55mA(Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA • • • Diagnostic • LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication Cl 1, Div 2; Groups A-D see InterlinkBT® drawing N1-2.400 T6, Ta = 70 degrees C For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-49-E413 to JBBS-49-E414 For fiberglass housing change part number to -Ex2x. Example: JBBS-49-E613 to JBBS-49-E623 30 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Short Circuit Protected Connector Size Connector Material Part Number Number of Ports Housing Material Quick Selection Guide JBBS-49-E813 8 euro aluminum stainless steel No JBBS-49-E613 6 euro aluminum stainless steel No JBBS-49-E413 4 euro aluminum stainless steel No JBBS-49-E814 8 euro aluminum nickel-plated brass No JBBS-49-E614 6 euro aluminum nickel-plated brass No JBBS-49-E414 4 euro aluminum nickel-plated brass No JBBS-49-E823 8 euro fiberglass stainless steel No JBBS-49-E623 6 euro fiberglass stainless steel No JBBS-49-E423 4 euro fiberglass stainless steel No JBBS-49-E824 8 euro fiberglass nickel-plated brass No JBBS-49-E624 6 euro fiberglass nickel-plated brass No JBBS-49-E424 4 euro fiberglass nickel-plated brass No JBBS-49SC-E813 8 euro aluminum stainless steel No JBBS-49SC-E613 6 euro aluminum stainless steel No JBBS-49SC-E413 4 euro aluminum stainless steel No InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 2 31 Device Gland Receptacles - 3 wire Selection Guide eurofast® minifast® 1/2 - NPT FSV 49-*M / 14.5 RSFV 49-*M / 14.5 3/4 - NPT FSV 49-*M / 14.75 RSFV 49-*M / 14.75 M20 FSV 49-*M / M20 RSFV 49-*M / M20 * For female receptacles change part number to (FKV, RKFV...). FSV 49-*M / 14.5 RSFV 49-*M / 14.5 FSV 49-*M / 14.75 RSFV 49-*M / 14.75 FSV 49-*M / M20 RSFV 49-*M / M20 minifast® eurofast® 1. 2. 3. 4. 32 Blue (-Voltage) Brown (+ Voltage) N/C Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Device Gland Receptacles - 2 wire Selection Guide eurofast® minifast® 1/2 - NPT FSV 49T -*M / 14.5 49T-*M RSFV 49T -*M / 14.5 49T-*M 3/4 - NPT FSV 49T -*M / 14.75 49T-*M RSFV 49T -*M / 14.75 49T-*M M20 FSV 49T -*M / M20 49T-*M RSFV 49T -*M / M20 49T-*M * Indicates length in meters. For female receptacles change part number to (FKV, RKFV...). 2 RSFV 49T -*M / 14.5 49T-*M FSV 49T -*M / 14.5 49T-*M FSV 49T -*M / 14.75 49T-*M RSFV 49T -*M / 14.75 49T-*M FSV 49T -*M / M20 49T-*M RSFV 49T -*M / M20 49T-*M minifast® eurofast® 1. 2. 3. 4. Blue (-Voltage) Brown (+Voltage) N/C N/C InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 33 Terminating Resistors Terminate at the beginning and end of each segment. minifast® Terminating Resistor • internal resistor and capacitor • male connector 1µF 100Ω RSV 49-TR eurofast® Terminating Resistor • internal resistor and capacitor • male connector 1µF 100Ω RSEV 49-TR For nickel-plated brass change: RSEV 49-TR to RSE 49-TR RSV 49-TR to RSM 49-TR 34 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 minifast® eurofast® 2-port BCA 49-M223 BCA 49-E223 1-port Conduit Adapter BCA 49-M123 BCA 49-E123 Schematic trunk drop drop trunk drop Change part number from BCA 49-M223 to BCA 49/P- M223 to fit on PVC coated conduit adapter. 2 Description The conduit adapter attaches to a standard conduit body for transition to minifast® or eurofast® connectors. • Gasket and mounting hardware included (8-32 x 1/2”) Pinout Dimensions 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) CROUSE - HINDS Hub Size = 3/4 Shape Style Part Number C Form 8 Mark 9 C28 C29 LB Form 8 Mark 9 LB28 LB29 LL Form 8 Mark 9 LL28 LL29 LR Form 8 Mark 9 LR28 LR29 Conduit Bodies Conduit connectors for use with armorfast® cable O-Z Gedney JMC-50-71 1/2NPT InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 35 FOUNDA ees TION™ fieldbus T OUNDATION Tees Part Number Dimensions Description RSV 2RKV 49 minifast® tee • data, ground, shield • stainless steel coupling nuts RSV FKV RKV 49 minifast® to eurofast® drop • data, ground, shield • stainless steel coupling nuts For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...) For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...) Part Number Dimensions Description RSCV 2RKCV 49 eurofast ® tee • stainless steel coupling nuts 36 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable T ee Wireable Tee 2 Description The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience. This allows an extremely rapid changeover to a connectorized network, often in less than 15 minutes. The Field Wireable IP67 Tee SPTTM13-A49 features standardized minifast® connectors for the drop connection and field wireable terminals on the trunk connections. This provides the best of both worlds, reliable connections on the short lengths and ease of installation planning on the long trunk runs. SPTTM13-A49 SPTT1-A49 Dimensions W ir eT able ire Table Specifications Pin Designation Color 1 V- Blue 2 V+ Brown 3 Shield Bare 4 Ground Green/Yellow InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 37 Gender Changers and Elbow Connectors Part Number Dimensions Description RSV RSV 49 minifast® Male Gender Changer • female cordset to male receptacle RKV RKV 49 minifast® Female Gender Changer • male cordset to female receptacle WSV RKV 49 minifast® Elbow • right angle male to female connector RSM 49-FK 4.5* minifast® to eurofast® Adapter • minifast ® male to eurofast® female connector • nickel-plated brass housing For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...) * = Consult factory for availability. 38 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Surge Suppressor Description This surge suppressor protects the data communication lines (V+ and V-) rather than just the shield. The unique multi-stage design provides superior surge protection. The surge suppressor absorbs the front end of the transient, responding in less than a nanosecond, then diverts the surge energy to ground. Once the surge has been dissipated the suppressor automatically resets and waits for the next surge. 2 The minifast ® connectors provide IEC IP67 protection in the rugged polyurethane overmolded body. The surge suppressor is available with stainless steel coupling nuts and a ground stud. RSV RKV 49 SS Dimensions Specifications Electrical • Maximum Operating Voltage: 27 Volts • Maximum Operating Current: 200mA • Clamping Action Turn-On: 28.5 Volts • Maximum Clamping at 2 kA: (8 X 20 µSec): 44 Volts • Maximum Surge Voltage: 20 kV • Maximum Surge Current: 2.5kA • Current Leakage/Line At Operating Voltage: 5µA • Capacitance/Line At Operating Voltage: 500pF • Response Time: Less than 1 nanosecond Mechanical • Ground Stud: 10-32 Stainless Steel • Operating Temperature: -40°C to +85°C InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 39 Power Supply Conditioner Description The Power Supply Conditioner meets the needs of redundant power supplies for FOUNDATION™ fieldbus. This product has primary and secondary power inputs to supply two Fieldbus H1 segments. Standard 24VDC power feeds into supplies A and B. It also takes care of filtering the fieldbus signal from the power source. LED’s indicate which Power Supply is primary and secondary. Diagnostics provide the status of each power supply, indicating either READY or ACTIVE. The status is also provided through relay outputs for further monitoring. Internal switches turn on/off terminators per segment. BRPC-49-M213 4-Pin Euro = Monitor 5-Pin Mini = Supply A & B Dimensions 4-Pin Mini = Segment 1 & 2 Electrical • Supply Voltage (Supply A & B): 12 - 32 VDC • Supply Surge Protection (Supply A & B): >36 VDC • Supply Redundancy (Supply A & B): Supply “A” is Primary. If Supply “A” Voltage drops below 11 V, Supply “B” becomes Active Supply “A” becomes Active once Voltage >11V Specifications 40 • • • Output Voltage (Segment 1 & 2): Input Voltage - 3 Volts Output Current (Segment 1 & 2): <1A Short Circuit Protection (Segment 1 & 2): >1A to Infinite Diagnostic • Power LED Indications: Green - Active / Red - No Power • Segment LED Indications: Green - Active • Supply Monitor Contacts (Supply A & B): Solid State, AC/DC <400 V, <70 mA when supply Voltage >11V, Contact Is Closed InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Lokfast™ Guard Field Standard Wireable minifast® eurofast® SHLD, MINI SHLD, EURO SHLD, MINI FW SHLD, EURO FW SHLD, MINI (10/bag) 2 Description The JTBS-49SC series short circuit brick is classified as nonincendive equipment. This means that it is considered nonarcing under normal operating conditions. In a fieldbus system the trunk does not need to be serviced under normal operating conditions. The trunk connections (P1 and S0) are to be locked with a Lokfast™ Guard to mechanically prevent separation. Assembly/ Disassembly Specifications Mechanical • Dimensions: 43mm X D/A X 39mm • Material: Nylon 6 • Environmental: Sun Resistant, UV Stable • Operating Temperature: -30ºC to 100ºC • Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 41 Bulkhead Feed-Thru Receptacles panel mount minifast® Bulkhead Receptacle • straight male/female feed thru RSFV RKF 49/22 eurofast® Bulkhead Receptacle • straight male/female feed thru FKV FSV 49/M12 For nickel-plated brass coupling nuts change part number to: RSFV RKFV 49/22 to RSF RKF 49/22 or FKV FSV 49/M12 to FKM FS 49/M12 42 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Panel Mount Receptacles - minifast®, eurofast® Female Male minifast® RKFV 49 - *M RSFV 49 - *M eurofast® FKV 49 - *M FSV 49 - *M minifast® RKFV 490 - *M RSFV 490 - *M eurofast® FKV 490 - *M FSV 490 - *M Cable Leads Selection Guide 2 * Indicates length in meters. RKFV 49 RSFV 49 FSV 49 FKV 49 Part numbers on diagrams represent solder cups only. eurofast® Female 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 43 Field W ireable Connectors - minifast® Wireable Aluminumx Stainless Steelx Female B 4149-0/9 BV 4149-0/9 Male BS 4149-0/9 BSV 4149-0/9 Selection Guide Accepts 6-8 mm (0.236” to 0.315”) cable B 4149-0/9 BS 4149-0/9 BV 4149-0/9 BSV 4149-0/9 Male Female 1. 2. 3. 4. 44 x - coupling nut material housing material - nylon Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable Connectors - eurofast ® Wireable Selection Guide Straight Right Angle Female B8141-0/PG9 B8241-0/PG9 Male BS8141-0/PG9 BS8241-0/PG9 Accepts 4-8 mm (0.157” to 0.315”) cable 2 B8141-0/PG9 B8241-0/PG9 BS8141-0/PG9 BS8241-0/PG9 Female eurofast® Male eurofast® 1. 2. 3. 4. Rating: 3 A, 36 VDC Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) Rating: 3 A, 36 VDC InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 45 Closure Caps Closure caps are for unused ports on the junction box. Dimensions Description RKMV BC minifast® closure cap • mates to male receptacles • Stainless steel • IP67 rated RSMV BC minifast® closure cap • mates to female receptacles • Stainless steel • IP67 rated RSFK-BC (10/BAG) minifas minifast® Closure Cap • mates to female receptacles • nylon VZ-3 (8/BAG) eurofast® Closure Cap • mates to female receptacles • nylon 46 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 PROFIBUS®-P A Cables and Accessories -PA 3 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 47 PROFIBUS®-P A -PA PROFIBUS®-PA (Process Automation) uses synchronous transfer mode technology, as defined in IEC 61158-2, to communicate between field devices and the RS 485 backbone of PROFIBUS®-DP. A segment coupler, or gateway is installed to bridge PROFIBUS®-DP with PROFIBUS®-PA. Otherwise, the protocols are identical, allowing transparent communication between general purpose automation systems and decentralized field devices. PROFIBUS®-PA is a master-slave bus. Transmitters used in the process industry are typically slave devices or passive stations which only communicate at the request of the master. General Layout T opologies Topologies The topology for PROFIBUS®-DP is a linear bus. Branching can be accomplished with repeaters or, in the case of PROFIBUS®-PA, this can be accomplished with the segment couplers. The PROFIBUS®-PA topology follows the physical layer as defined in ISA SP50.02. daisy chain or star topologies are allowed. 48 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Star T opology Method Topology A star topology has a central connection point to all terminations. This layout works well when there are many devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the fieldbus segment. The best design would be to connect them all to a junction brick and then run a Home Run cable e 4 for a pictorial example. from the junction brick back to the control room. See Figur Figure The Home Run cable is considered the main trunk line of communication. Each device that is connected to the junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line. 3 Figure 4 - Star Topology Example Daisy Chain Configuration Another layout design is to daisy chain all the devices. Each device would require a tee so that the Home Run cable would be able to go to each device. From a design standpoint, the Daisy Chain method is easiest to do when the exact cable tracks are known. Pre-made cordsets can then be purchased and the network is easy to e 5 for an example drawing. A fieldbus transmitter is connected to each of the tanks in the assemble. See Figur Figure field. The Home Run cable essentially is routed to each device in series. Transmitters Figure 5 - Daisy Chain Layout In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. Remember that one of the benefits to fieldbus is reduced wiring of devices, leading to faster start-up times. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 49 Fieldbus Cable Specifications The specifications for PROFIBUS®-PA physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2 Physical Layer Standards. There are essentially four types of cable designations for fieldbus. Type A cable is the most preferred for new installations because it allows for the most versatile lengths. The other types of cable are able 1 for installations where cable already exists from 4-20 mA systems. See T Table 1. Type Cable Description Conductor Size Maximum Length Type A Shielded, Twisted Pair # 18 Awg 1900 m (6232 ft) Type B Shielded, Multi Twisted Pair # 22 Awg 1200 m (3936 ft) Type C Unshielded, Multi Twisted Pair # 26 Awg 400 m (1312 ft) Type D Shielded, Untwisted Pair # 16 Awg 200 m (656 ft) Table 1 Fieldbus Cable Specifications InterlinkBT® offers cables with both two conductors and three conductors, with the third conductor available for a centralized ground of devices if needed. InterlinkBT® cables meet or exceed the specifications of ANSI/ISA-SP50.021992, the fieldbus standard for use in industrial control systems. The maximum spur length is determined by the number of devices in the segment. Cable Trunk 1900 m 50 Number of Devices Maximum Spur Length 25-32 0 m (0 ft) 19-24 30 m (98 ft) 15-18 60 m (197 ft) 13-14 90 m (295 ft) 2-12 120 m (394 ft) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 PROFIBUS®-P A - Cable Specifications -PA Our cable meets requirements of ISA/SP50 and PROFIBUS®-PA Type A cable. All cables are rated -40ºC to 105ºC and are sunlight resistant. Available in 3-wire versions with a device ground or 2-wire versions. 1 Cable Specifications Type A Cable - Designed for harsh environments - Temperature range of -40 to 105°C (-40 to +221F) 11 - Governed by: ISA SP50.02 specification - Sunlight resistant per test - PLTC and ITC rated (CSA FT4) - Impedence[Z0 at fr (31.25 kHz)] = 100Ω ± 20% - Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km - Maximum capacitive unbalance to shield = 2 nF/km - Maximum DC resistance (per conductor) = 24 Ω/km - Maximum propagation delay variance 0. 25 fr to 1.25 fr = 1.7 µs/km - Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG) - Minimum shield coverage shall be 90% Data Pair Type 483 105°C 300V 483B 105°C 300V 482A 105°C 300V 482BA 105°C 300V 483BK 105°C 300V Approvals 33 Device Ground Outer Jacket Shield AWG Color Code DCR (/1000 ft) Insulation AWG Color Code Material Color Nominal O.D. Type Drain Wire Bulk Cable Part No. Ref. NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Orange 7.9mm (.310 in.) Foil/Braid 20 AWG RB50785-*M 1 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Blue 7.9mm (.310 in.) Foil/Braid 20 AWG RB50786-*M 1 NEC ITC PLTC/CM CEC [CMG HLBCD] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Orange 12.7mm (0.5 in.) Foil 18 AWG RB50929-*M 11 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Blue 12.7mm (0.5 in.) Foil 18 AWG RB50952-*M 11 NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Black 7.9mm (.310 in.) Foil/Braid 20 AWG RB50860-*M 1 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 51 PROFIBUS®-P A - C ables and C or dsets -PA ordsets minifast® † Try Cordset Builder Online! Pin (Male) www.interlinkbt.com RSV WSV eurofast® Pin (Male) Socket (Female) RKV RSCV WKV RSV 48x - *M WSV 48x -*M RKV 48x -*M WKV 48x -*M RSCV 48x -*M RSV RSV 48x -*M RSV WSV 48x -*M RSV RKV 48x -*M RSV WKV 48x -*M RSV RSCV 48x -*M WSV WSV 48x -*M WSV RKV 48x -*M WSV WKV 48x -*M WSV RSCV 48x -*M RKV RKV 48x -*M RKV WKV 48x -*M RKV RSCV 48x -*M WKV WKV 48x -*M WKV RSCV 48x -*M RSV WSV Socket (Female) minifast®† Pin (Male) Bare RKV × * † RSCV RSCV 48x -*M RSCV WSCV Socket (Female) eurofast® Pin (Male) WKV RKCV WKCV Indicates cable type Indicates length in meters Consult factory for availability of armorfast® with eurofast® connectors. armorfast ® cable only For nickel-plated brass coupling nut: RSV...to RSM... RSCV...to RSC... Bulk cable, see page 8 for standard lengths WSV RSCV 482-*M Example 1 METER 52 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 PROFIBUS®-P A - C ables and Cor dsets -PA ordsets eurofast® Pin (Male) WSCV WSCV 48x -*M minifast® bulkhead Socket (Female) RKCV RKCV 48x -*M WKCV WKCV 48x -*M Pin (Male) RSFPV RSFPV 48x -*M Socket (Female) RKFPV eurofast® bulkhead Pin (Male) FSFDV Socket (Female) FKFDV RKFPV 48x -*M FSFDV 48x -*M FKFDV 48x -*M RSV WSCV 48x -*M RSV RKCV 48x -*M RSV WKCV 48x -*M RSV RSFPV 48x -*M RSV RKFPV 48x -*M RSV FSFDV 48x -*M RSV FKFDV 48x -*M WSV WSCV 48x -*M WSV RKCV 48x -*M WSV WKCV 48x -*M WSV RSFPV 48x -*M WSV RKFPV 48x -*M WSV FSFDV 48x -*M WSV FKFDV 48x -*M RKV WSCV 48x -*M RKV RKCV 48x -*M RKV WKCV 48x -*M RKV RSFPV 48x -*M RKV RKFPV 48x -*M RKV FSFDV 48x -*M RKV FKFDV 48x -*M WKV WSCV 48x -*M WKV RKCV 48x -*M WKV WKCV 48x -*M WKV RSFPV 48x -*M WKV RKFPV 48x -*M WKV FSFDV 48x -*M WKV FKFDV 48x -*M RSCV WSCV 48x -*M RSCV RKCV 48x -*M RSCV WKCV 48x -*M RSCV RSFPV 48x -*M RSCV RKFPV 48x -*M RSCV FSFDV 48x -*M RSCV FKFDV 48x -*M WSCV WSCV 48x -*M WSCV RKCV 48x -*M WSCV WKCV 48x -*M WSCV RSFPV 48x -*M WSCV RKFPV 48x -*M WSCV FSFDV 48x -*M WSCV FKFDV 48x -*M RKCV RKCV 48x -*M RKCV WKCV 48x -*M RKCV RSFPV 48x -*M RKCV RKFPV 48x -*M RKCV FSFDV 48x -*M RKCV FKFDV 48x -*M WKCV WKCV 48x -*M WKCV RSFPV 48x -*M WKCV RKFPV 48x -*M WKCV FSFDV 48x -*M WKCV FKFDV 48x -*M InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3 53 minifast® C or dset and Receptacle Connector D imensions and Pinouts ordset RSV -* RSV-* RKV -* RKV-* WSV -* WSV-* WKV-* RSFPV -* RSFPV-* RKFPV -* RKFPV-* Mounting Installation 5.0 1.8 30.5 Female Male 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) 54 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 eurofast® C or dset and R eceptacle C onnector D imensions and Pinouts ordset RSCV -* RSCV-* RKCV -* RKCV-* WSCV -* WSCV-* WKCV -* WKCV-* 3 FSFDV -* FSFDV-* Mounting Installation FKFDV -* FKFDV-* Female Male 1. Brown (+ Voltage) 2. N/C 3. Blue (- Voltage) 4. Bare (Shield Drain Wire) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 55 Short Circuit minifast® Junction T ee Tee SC models only Description The PROFIBUS®-PA junction tee is available with short circuit protection. Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance. JTBS-48SC-M633 4-Pin Male P1 4-Pin Female Dimensions S0-S6 MOUNTING SCREW 1/4” (2) NOT INCLUDED Short Circuit Protection (only available with SC models) Specifications Electrical Short Circuit Protection: 55mA(Isc) Voltage Open Circuit: 35VDC Current Consumption: 5mA • • • Diagnostic • LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication 56 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Connector size Overmold material Short Circuit Protected Number of ports Connector material Quick Selection Guide JTBS-48-M433 4 mini polyurethane stainless steel No JTBS-48-M434 4 mini polyurethane nickel-plated brass No JTBS-48-M633 6 mini polyurethane stainless steel No JTBS-48-M634 6 mini polyurethane nickel-plated brass No JTBS-48SC-M433 4 mini polyurethane stainless steel Yes JTBS-48SC-M434 4 mini polyurethane nickel-plated brass Yes JTBS-48SC-M633 6 mini polyurethane stainless steel Yes JTBS-48SC-M634 6 mini polyurethane nickel-plated brass Yes JTBS-48-E433 4 euro polyurethane stainless steel No JTBS-48-E434 4 euro polyurethane nickel-plated brass No JTBS-48-E633 6 euro polyurethane stainless steel No JTBS-48-E634 6 euro polyurethane nickel-plated brass No JTBS-48SC-E433 4 euro polyurethane stainless steel Yes JTBS-48SC-E434 4 euro polyurethane nickel-plated brass Yes JTBS-48SC-E633 6 euro polyurethane stainless steel Yes JTBS-48SC-E634 6 euro polyurethane nickel-plated brass Yes Part Number InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3 57 minifast® Passive Multiport Junctions (Bricks) SC models only Description • Keyed for PROFIBUS®-PA Systems • Rugged, fully encapsulated die-cast aluminum enclosures • Bus-In/Bus-Out eliminate need for splitter tee • Provide common ground for all devices • Stainless steel receptacles JBBS-48-M813 JBBS-48-M613 JBBS-48-M413 Dimensions / Part Number Short Circuit Protection (only available with SC models) Applications Electrical • Short Circuit Protection: 55mA(Isc) • Voltage Open Circuit: 35VDC • Current Consumption: 5mA Diagnostic • LED Indication: Green LED - Bus Power Red LED - Short Circuit Indication For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-48-M413 to JBBS-48-M414 For fiberglass housing change part number to -Mx2x. Example: JBBS-48-M613 to JBBS-48-M623 58 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Connector size Housing material Short Circuit Protected Number of ports Connector material Quick Selection Guide JBBS-48-M813 8 mini aluminum stainless steel No JBBS-48-M613 6 mini aluminum stainless steel No JBBS-48-M413 4 mini aluminum stainless steel No JBBS-48-M814 8 mini aluminum nickel-plated brass No JBBS-48-M614 6 mini aluminum nickel-plated brass No JBBS-48-M414 4 mini aluminum nickel-plated brass No JBBS-48-M823 8 mini fiberglass stainless steel No JBBS-48-M623 6 mini fiberglass stainless steel No JBBS-48-M423 4 mini fiberglass stainless steel No JBBS-48-M824 8 mini fiberglass nickel-plated brass No JBBS-48-M624 6 mini fiberglass nickel-plated brass No JBBS-48-M424 4 mini fiberglass nickel-plated brass No JBBS-48SC-M813 8 mini aluminum stainless steel Yes JBBS-48SC-M613 6 mini aluminum stainless steel Yes JBBS-48SC-M413 4 mini aluminum stainless steel Yes Part Number InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3 59 eurofast® Passive Multiport Junctions (Bricks) Description • • • • • Keyed for PROFIBUS®-PA Systems Rugged, fully encapsulated die-cast aluminum enclosures Bus-In/Bus-Out eliminate need for splitter tee Provide common ground for all devices Stainless steel receptacles JBBS-48-E813 JBBS-48-E613 JBBS-48-E413 Dimensions / Part Number Applications 8, 6, and 4-Port Junction Bricks • bus-in / bus-out straight throughports • spurs with eurofast® connectors For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-48-E413 to JBBS-48-E414 For fiberglass housing change part number to -Ex2x. Example: JBBS-48-E613 to JBBS-48-E623 60 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Connector size Housing material Short Circuit Protected Part Number Number of ports Connector material Quick Selection Guide JBBS-48-E813 8 euro aluminum stainless steel No JBBS-48-E613 6 euro aluminum stainless steel No JBBS-48-E413 4 euro aluminum stainless steel No JBBS-48-E814 8 euro aluminum nickel-plated brass No JBBS-48-E614 6 euro aluminum nickel-plated brass No JBBS-48-E414 4 euro aluminum nickel-plated brass No JBBS-48-E823 8 euro fiberglass stainless steel No JBBS-48-E623 6 euro fiberglass stainless steel No JBBS-48-E423 4 euro fiberglass stainless steel No JBBS-48-E824 8 euro fiberglass nickel-plated brass No JBBS-48-E624 6 euro fiberglass nickel-plated brass No JBBS-48-E424 4 euro fiberglass nickel-plated brass No InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3 61 Device Gland Receptacles - 2 wire Selection Guide eurofast® minifast® 1/2 - NPT FSV 48T -*M / 14.5 48T-*M RSFV 48T -*M / 14.5 48T-*M 3/4 - NPT FSV 48T -*M / 14.75 48T-*M RSFV 48T -*M / 14.75 48T-*M M20 FSV 48T -*M / M20 48T-*M RSFV 48T -*M / M20 48T-*M * Indicates length in meters. For female receptacles change part number to (FKV, RKFV...). RSFV 48T -*M / 14.5 48T-*M FSV 48T -*M / 14.5 48T-*M FSV 48T -*M / 14.75 48T-*M RSFV 48T -*M / 14.75 48T-*M FSV 48T -*M / M20 48T-*M RSFV 48T -*M / M20 48T-*M eurofast® minifast® 1. 2. 3. 4. 62 Brown (+ Voltage) N/C Blue (- Voltage) N/C InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Terminating Resistors terminate at the beginning and end of each segment 3 minifast® Terminating Resistor • internal resistor and capacitor • male connector 1µF 100Ω RSV 48-TR eurofast® Terminating Resistor • internal resistor and capacitor • male connector 1µF 100Ω RSEV 48-TR For nickel-plated brass change: RSEV 48-TR to RSE 48-TR RSV 48-TR to RSM 48-TR InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 63 Terminating Resistors - Ex terminate at the beginning and end of each segment minifast® Terminating Resistor • internal resistor and capacitor • male connector 1µF 100Ω RSV 48-TR-Ex eurofast ® Terminating Resistor • internal resistor and capacitor • male connector 1µF 100Ω RSEV 48-TR-Ex For nickel-plated brass change: RSEV 48-TR-Ex to RSE 48-TR-Ex RSV 48-TR-Ex to RSM 48-TR-Ex Ex Approval BVS 99.E.2044X Entity Parameters: U : ≥ 16.2V I : ≥ 500mA P : ≥ 1.8W T: -40ºC...+70ºC (EEx ia IIC T4) -40ºC...+70ºC (EEx ia IIC T6) 0 0 0 a 64 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Conduit Adapter minifast® Schematic 2-port BCA 48-E223 BCA 48-M123 BCA 48-E123 drop BCA 48-M223 1-port trunk drop trunk drop Description eurofast® The conduit adapter attaches to a standard conduit body for transition to minifast® or eurofast® connectors. • Gasket and mounting hardware included (8-32 x 1/2”) Pinout 3 Dimensions 1. 2. 3. 4. Brown (+ Voltage) N/C Blue (- Voltage) Bare (Shield Drain Wire) CROUSE - HINDS Hub Size = 3/4 Shape Style Part Number C Form 8 Mark 9 C28 C29 LB Form 8 Mark 9 LB28 LB29 LL Form 8 Mark 9 LL28 LL29 LR Form 8 Mark 9 LR28 LR29 Conduit Bodies Conduit connectors for use with armorfast® cable O-Z Gedney JMC-50-71 1/2NPT InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 65 PROFIBUS®-P A T ees -PA Tees Part Number Dimensions Description RSV 2RKV 48 minifast® tee • data, ground, shield • stainless steel coupling nuts RSV FKV RKV 48 minifast ® to eurofast® drop • data, ground, shield • stainless steel coupling nuts For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...) For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...) Part Number Dimensions Description RSCV 2RKCV 48 eurofast® tee • stainless steel coupling nuts 66 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable T ee Wireable Tee Description The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience. This allows an extremely rapid changeover to a connectorized network, often in less than 15 ® minutes. The Field Wireable IP67 SPTTM13-A48 tee features standardized minifast connectors for the drop connection and field wireable terminals on the trunk connections. This provides the best of both worlds, reliable connections on the short lengths and ease of installation planning on the long trunk runs. SPTT1-A48 SPTTM13-A48 3 Dimensions W ir eT able ire Table Specifications Pin Designation Color 1 PA+ Brown 2 N/C -- 3 PA- Blue 4 Shield Drain InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 67 Gender Changers and Elbow Connectors Part Number Dimensions Description RSV RSV 48 minifast® Male Gender Changer • female cordset to male receptacle RKV RKV 48 minifast® Female Gender Changer • male cordset to female receptacle WSV RKV 48 minifast® Elbow • right angle male to female connector RSM 48-FK 4.5* minifast® to eurofast® Adapter • minifast® male to eurofast® female connector • nickel-plated brass housing For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...) Consult factory for availability of stainless steel. 68 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Surge Suppressor Description This surge suppressor protects the data communication lines (V+ and V-) rather than just the shield. The unique multi-stage design provides superior surge protection. The surge suppressor absorbs the front end of the transient, responding in less than a nanosecond, then diverts the surge energy to ground. Once the surge has been dissipated the suppressor automatically resets and waits for the next surge. The minifast® connectors provide IP67 protection in the rugged polyurethane overmolded body. The surge suppressor is available with stainless steel coupling nuts and ground stud. RSV RKV 48 SS 3 Dimensions Specifications Electrical • Maximum Operating Voltage: 27 Volts • Maximum Operating Current: 200mA • Clamping Action Turn-On: 28.5 Volts • Maximum Clamping at 2 kA: (8 X 20 µSec) : 44 Volts • Maximum Surge Voltage: 20 kV • Maximum Surge Current: 2.5kA • Current Leakage/Line At Operating Voltage: 5µA • Capacitance/Line At Operating Voltage: 500pF • Response Time: Less than 1 nanosecond Mechanical • Ground Stud: 10-32 Stainless Steel • Operating Voltage: 24 Volts • Operating Temperature: -40°C to +85°C InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 69 Lokfast™ Guard Field Standard Wireable minifast® eurofast® SHLD, MINI SHLD, EURO SHLD, MINI FW SHLD, EURO FW SHLD, MINI (10/bag) Description The JTBS-48SC series short circuit brick is classified as nonincendive equipment. This means that it is considered nonarcing under normal operating conditions. In a fieldbus system the trunk does not need to be serviced under normal operating conditions. The trunk connections (P1 and S0) are to be locked with a Lokfast™ Guard to mechanically prevent separation. Assembly/ Disassembly Specifications 70 Mechanical • Dimensions: 43mm X D/A X 39mm • Material: Nylon 6 • Environmental: Sun Resistant, UV Stable • Operating Temperature: -30ºC to 100ºC • Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Bulkhead Feed-Thru Receptacles panel mount 3 minifast® Bulkhead Receptacle • straight male/female feed thru RSFV RKF 48/22 eurofast® Bulkhead Receptacle • straight male/female feed thru FKV FSV 48/M12 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 71 Panel Mount Receptacles - minifast®, eurofast® Female Male minifast® RKFV 48 - *M RSFV 48 - *M eurofast® FKV 48 - *M FSV 48 - *M minifast® RKFV 483 - *M RSFV 483 - *M eurofast® FKV 483 - *M FSV 483 - *M cable leads Selection Guide RKFV 48 - *M RSFV 48 - *M FKV 48 - *M FSV 48 - *M eurofast® Female 1. 2. 3. 4. 72 Brown (+ Voltage) N/C Blue (- Voltage) Bare (Shield Drain Wire) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable Connectors - minifast® Wireable Selection Guide Aluminumx Stainless Steelx Female B 4148-0/9 BV 4148-0/9 BS 4148-0/9 BSV 4148-0/9 Male x - coupling nut housing material - nylon Accepts 6-8 mm (0.236” to 0.315”) cable B 4148-0/9 BS 4148-0/9 3 BSV 4148-0/9 BV 4148-0/9 Male Female 1. 2. 3. 4. Brown (+ Voltage) N/C Blue (- Voltage) Bare (Shield Drain Wire) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 73 Field W ireable Connectors - eurofast® Wireable Selection Guide Straight Right Angle Female B8141-0/PG9 B8241-0/PG9 Male BS8141-0/PG9 BS8241-0/PG9 Field wireable connectors for bus lines and drops facilitate field replacement. B8141-0/PG9 B8241-0/PG9 BS8141-0/PG9 BS8241-0/PG9 Male eurofast® Female eurofast® 1. 2. 3. 4. Rating: 3 A, 36 VDC 74 Brown (+ Voltage) N/C Blue (- Voltage) Bare (Shield Drain Wire) Rating: 3 A, 36 VDC InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Closure Caps Closure caps are for unused ports on the junction box. Dimensions Description RKMV BC minifast® closure cap • mates to male receptacles • Stainless steel • IP67 rated RSMV BC minifast® closure cap 3 • mates to female receptacles • Stainless steel • IP67 rated RSFK-BC (10/BAG) minifast® Closure Cap • mates to female receptacles • nylon VZ-3 (8/BAG) eurofast® Closure Cap • mates to female receptacles • nylon InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 75 HAR T ® Cables and Accessories HART 76 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 HART® Overview HART® (Highway Addressable Remote Transducer) is a protocol which supports two-way digital communication for process measurement and control devices. Although it is not an international standard, it is considered an “open” protocol, broadly accepted in the process industry. HART® devices can store process related information and communicate digitally. It can also be used with traditional 4-20 mA devices. This is beneficial if there is a large existing installed base of 4-20 mA transmitters. HART® is a master-slave protocol. This means that when the master calls out the slave’s address, the slave responds. The master takes control of the time and operational sequence of the bus. There can be two masters, including a hand-held communicator. Up to 15 slave devices can be connected to one multidrop line (limitations exist for intrinsically safe areas). HART® uses the Bell 202 standard frequency shift keying (FSK) for digital communication. The FSK signal is superimposed on the 4 to 20 mA analog measurement signal. The FSK signal does not cause interference with the analog measurement since the average value is zero. The frequency of 1200 hz is used for a logical ‘1’ and 2200 hz is used for a logical ‘0’. General Layout Topologies Field wiring of HART® uses twisted pair cable, either screened as a pair in a cable or multiple screens and an overall screen on cable containing multiple pairs. There are two basic structures for wiring a system. The first is point-topoint wiring. This means that every pair that connects to an instrument is returned to the control, completely isolated from the other pairs. This can either be accomplished with twisted pair cable or a bundled multiple pair cable. See Figure 6 6. The second type of structure is multidrop wiring. This can be used when the HART® enabled transmitters are operating in digital communication only. The transmitters may be wired with a trunk and drop layout (or a Daisy Chain). See Figure 7 7. Either of these methods greatly reduce wiring and allow for the most flexibility in expansion. 4 Figur e 6 - Point-to-Point Example Figure Figur e 7 - Multidrop Example Figure InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 77 HART® Cable Specifications The maximum HART® cable length is 1500 meters. However, the physical media is limited by a maximum system attenuation of 3 dB. This is ensured if there is a resistance-capacitance combination having an RC time-constant value of 65 µF (the circuit resistance R divided by the capacitance C). The system design must consider both resistance of the device and the cable, likewise the capacitance of the device and the cable. In a typical system the host load resistance is 250Ω. HART® recommends a maximum capacitance of 5000 pF on slave devices. Devices with higher capacitance must list the capacitance number (CN). This number equals the actual device capacitance divided by 5000 pF. For example, a device with a capacitance of 10,000 pF would have CN = 2. Resistance is measured for both conductors in series. Capacitance is measured from one conductor to all others and the screen. The values for InterlinkBT® cables are as follows: Cable T ype Description Type H40 H120 H190 HM40 2 X 22 AWG + 20 Device Ground 4 Pair, 2 X 22 AWG + 18 AWG Device Ground 8 Pair, 2 X 22 AWG + 18 AWG Device Ground 2 X 18 AWG + Device Ground Capacitance 150 pF/m 190 pF/m 260 pF/m 140 pF/m Pair Resistance 112Ω/1000 m 112Ω/1000 m 112Ω/1000 m 43Ω/1000 m The maximum cable distance is dependent on the cable type and the total capacitance of the devices. The graph below provides guidelines for cable distances based on the standard InterlinkBT® cable and assuming a 250Ω load resistor. In the example if the system consisted of 9 devices with an average CN of 2 (i.e. 10,000 pF each) and a host with 5000 pF capacitance, which totals 0.095 µF (95,000 pF), the maximum cable length would be 900 meters using multidrop structure cable HM40. Maximum Cable Length 250 ohm Load Resistor Device CTotal (µF) 0.30 H40 H120 H190 HM40 0.20 0.10 0.00 0 500 1000 1500 Length (meters) HART® simulation software to determine maximum lengths can be found at www.romilly.co.uk. The software H-SIM can be downloaded free of charge. 78 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 HAR T ® - Cable Specifications HART A B C D Twisted pair cable, screened as individual pairs as specified in HART® Field Communication Protocol Technical Overview. 4 Data Pair Approvals Type H40 105°C 300V H40A 105°C 300V H120 105°C 300V H190 105°C 300V HM40 105°C 300V Device Ground Outer Jacket Shield AWG Color Code DCR (/1000 ft) Insulation AWG Color Code Material Color Nominal O.D. Type Drain Wire Network Standard Ref. NEC PLTC CEC [CMG] 2/22 AWG Blue/Brn 16.5 Ohms PE 20 AWG Green/Yellow PVC Grey 7.2mm (.285 in.) Foil 22 AWG RB50824-*M A NEC ITC PLTC CEC [CMG] 2/18 AWG Blue/Brn 6.5 Ohms PE 18 AWG Green/Yellow Armor/PVC Grey 7.9mm (.310 in.) Foil 18 AWG RB50939-*M B NEC ITC PLTC/CM CEC [CMG HLBCD] 4 Pairs 2/22 AWG 16.5 Ohms PE 18 AWG Green/Yellow PVC Grey 12.7mm (0.5 in.) Foil 18 AWG RB50825-*M D NEC ITC PLTC/CM CEC [CMG HLBCD] 8 Pairs 2/22 AWG 16.5 Ohms PE 18 AWG Green/Yellow PVC Grey 12.7mm (0.5 in.) Foil 18 AWG RB50826-*M C NEC PLTC CEC [CMG]] 2/18 AWG Blue/Brn 6.5 Ohms PE None PVC Grey 7.9mm (.310 in.) Foil 20 AWG RB50938-*M A InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 79 HAR T ® - Cables and Cor dsets HART Cordsets minifast® † Pin (Male) RSV RSV Hx 4x - *M WSV eurofast® Pin (Male) Socket (Female) RKV RSCV WKV WKV Hx 4x - *M RSCV Hx 4x - *M WSV Hx 4x - *M RKV Hx 4x - *M RSV WSV Hx 4x - *M RSV RKV Hx 4x - *M RSV WKV Hx 4x - *M RSV RSCV Hx 4x - *M WSV WSV Hx 4x - *M WSV RKV Hx 4x - *M WSV WKV Hx 4x - *M WSV RSCV Hx 4x - *M RKV RKV Hx 4x - *M RKV WKV Hx 4x - *M RKV RSCV Hx 4x - *M WKV WKV Hx 4x - *M WKV RSCV Hx 4x - *M Pin (Male) RSV RSV Hx 4x - *M RSV WSV Socket (Female) minifast® † Bar e Bare RKV × * † Pin (Male) RSCV RSCV Hx 4x - *M RSCV WSCV Socket (Female) eurofast® WKV RKCV WKCV Indicates cable type Indicates length in meters Consult factory for availability of armorfast® with eurofast® connectors. Armorfast® cable only For nickel-plated brass coupling nut: RSV...to RSM... RSCV...to RSC... Bulk cable, see page 8 for standard lengths. Example 80 WSV RSCV H40-1M 1 METER InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 HAR T ® - Cables and Cor dsets HART Cordsets eurofast® Pin (Male) WSCV minifast® bulkhead Socket (Female) RKCV WKCV Pin (Male) RSFPV Socket (Female) RKFPV eurofast® bulkhead Pin (Male) FSFDV Socket (Female) FKFDV WSCV Hx 4x - *M RKCV Hx 4x - *M WKCV Hx 4x - *M RSFPV Hx 4x - *M RKFPV Hx 4x - *M FSFDV Hx 4x - *M FKFDV Hx 4x - *M RSV WSCV Hx 4x - *M RSV RKCV Hx 4x - *M RSV WKCV Hx 4x - *M RSV RSFPV Hx 4x - *M RSV RKFPV Hx 4x - *M RSV FSFDV Hx 4x - *M RSV FKFDV Hx 4x - *M WSV WSCV Hx 4x - *M WSV RKCV Hx 4x - *M WSV WKCV Hx 4x - *M WSV RSFPV Hx 4x - *M WSV RKFPV Hx 4x - *M WSV FSFDV Hx 4x - *M WSV FKFDV Hx 4x - *M RKV WSCV Hx 4x - *M RKV RKCV Hx 4x - *M RKV WKCV Hx 4x - *M RKV RSFPV Hx 4x - *M RKV RKFPV Hx 4x - *M RKV FSFDV Hx 4x - *M RKV FKFDV Hx 4x - *M WKV WSCV Hx 4x - *M WKV RKCV Hx 4x - *M WKV WKCV Hx 4x - *M WKV RSFPV Hx 4x - *M WKV RKFPV Hx 4x - *M WKV FSFDV Hx 4x - *M WKV FKFDV Hx 4x - *M RSCV WSCV Hx 4x - *M RSCV RKCV Hx 4x - *M RSCV WKCV Hx 4x - *M RSCV RSFPV Hx 4x - *M RSCV RKFPV Hx 4x - *M RSCV FSFDV Hx 4x - *M RSCV FKFDV Hx 4x - *M 4 WSCV WSCV Hx 4x - *M WSCV RKCV Hx 4x - *M WSCV WKCV Hx 4x - *M WSCV RSFPV Hx 4x - *M WSCV RKFPV Hx 4x - *M WSCV FSFDV Hx 4x - *M WSCV FKFDV Hx 4x - *M RKCV RKCV Hx 4x - *M RKCV WKCV Hx 4x - *M RKCV RSFPV Hx 4x - *M RKCV RKFPV Hx 4x - *M RKCV FSFDV Hx 4x - *M RKCV FKFDV Hx 4x - *M WKCV WKCV Hx 4x - *M WKCV RSFPV Hx 4x - *M WKCV RKFPV Hx 4x - *M WKCV FSFDV Hx 4x - *M WKCV FKFDV Hx 4x - *M InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 81 minifast® Cor dset and Receptacle Connector Dimensions and Pinouts Cordset RSV -* RSV-* RKV -* RKV-* WSV -* WSV-* WKV-* RSFPV -* RSFPV-* RKFPV -* RKFPV-* Male Female 1. 2. 3. 4. 82 Mounting Installation Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 eurofast® Cor dset and Receptacle Connector Dimensions and Pinouts Cordset RSCV -* RSCV-* RKCV -* RKCV-* WSCV -* WSCV-* WKCV -* WKCV-* FSFDV -* FSFDV-* FKFDV -* FKFDV-* Mounting Installation 4 Male Female 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 83 HAR T ® - Cables and Cor dsets HART Cordsets multifast® Pin (Male) CSM CSM H1xx -*M CSWM Socket (Female) CKM CKWM CSWM H1xx -*M CKM H1xx -*M CKWM H1xx -*M CSM CSWM H1xx -*M CSM CKM H1xx -*M CSM CKWM H1xx -*M CSWM CSWM H1xx -*M CSWM CKM H1xx -*M CSWM CKWM H1xx -*M CKM CKM H1xx -*M CKM CKWM H1xx -*M Pin (Male) CSM CSM H1xx -*M CSM CSWM Socket (Female) multifast® Bare CKM CKWM CKWM H1xx -*M CKWM Coupling nuts shown are nickel-plated brass. Consult factory for availability of stainless steel. × * Indicates cable type Indicates length in meters CSWM CKM H1 - 1M Bulk cable, see page 8 for standard lengths. Example 1 METER 84 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 multifast® Receptacle Connector Dimensions and Pinouts CSM ...CKM... CSM...CKM... CSWM ...CKWM... CSWM...CKWM... Functional W iring Diagram Wiring for 12-Pin Cor dset Cordset NAMUR HAR T® HART J1 J2 J3 J4 V+ VDrain V+ VDrain V+ VDrain V+ VDrain Gr ound Ground Drain Functional W iring Diagram Wiring for 19-Pin Cor dset Cordset NAMUR HAR T® HART Color VV+ Drain VV+ Drain VV+ Drain VV+ Drain Gr ound Ground Drain J1 J2 J3 J4 J5 J6 J7 J8 V+ VDrain V+ VDrain V+ VDrain V+ VDrain V+ VDrain V+ VDrain V+ VDrain V+ VDrain Gr ound Ground Drain Color VV+ Drain VV+ Drain VV+ Drain VV+ Drain VV+ Drain VV+ Drain VV+ Drain VV+ Drain Gr ound Ground Drain 4 Male Female Male Female 12-pin 12-pin 19-pin 19-pin InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 85 HAR T ® Junction T ee HART Tee Description The HART® junction tee provides a rugged connection to all of your fieldbus devices. Mechanically rugged, the new overmolded design provides unparalled corrosive resistance. It is also available with either multifast® connectors for point-to-point wiring, or minifast® connectors for multidrop installations. JTBS-40H-CS12 P1 12-Pin Male MOUNTING SCREW 1/4” (2) NOT INCLUDED J0-J4 JTBS-70H-CS19 P1 19-Pin Male J0-J7 JTBS-60HM-RS4 P1 4-Pin Male J0-J6 Dimensions * change RS to RSV for stainless steel connectors change CS to CSV for stainless steel connectors (consult factory for availability) Schematic/ Connector W iring 4-port W iring 7-port W iring Multidr op Multidrop HAR TT ransmitter HART Transmitter NAMUR Sensor 86 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 mini polyurethane stainless steel No JTBS-40H-CS12 4 12-pin multi mini polyurethane nickel-plated brass No JTBS-70H-CSV19* 7 19-pin multi mini polyurethane stainless steel No JTBS-70H-CS19 7 19-pin multi mini polyurethane nickel-plated brass No JTBS-40HM-RSV4 4 4-pin mini mini polyurethane stainless steel No JTBS-40HM-RS4 4 4-pin mini mini polyurethane nickel-plated brass No JTBS-60HM-RSV4 6 4-pin mini mini polyurethane stainless steel No JTBS-60HM-RS4 6 4-pin mini mini polyurethane nickel-plated brass No Connector Material 12-pin multi Overmold Material 4 (J0-JX) Home Run Connector (P1) JTBS-40H-CSV12* Connector Size Part Number Number of Ports Short Circuit Protected Quick Selection Guide * Consult factory for availability InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 4 87 eurofast® Multibox Aluminum Junctions (Bricks) Brick for HART®; point-to-point with Home Run connector. Description • Aluminum enclosure • Nickel-plated brass connectors Consult factory for availability of stainless steel. VBM-40H-CS12 VBM-80H-CS19 Dimensions Schematic/ Connector W iring 4-port W iring 8-port HAR TT ransmitter HART Transmitter NAMUR Sensor 88 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 eurofast® Multibox Nylon Junctions (Bricks) Description Brick for HART®; point-to-point with Home Run connector • Nylon enclosure • Nickel-plated brass connectors Consult factory for availability of stainless steel. 4MB12-40H-CS12 8MB12-40H-CS19 Dimensions Schematic/ Connector W iring 4-port W iring 8-port 4 HAR TT ransmitter HART Transmitter NAMUR Sensor InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 89 Device Gland Receptacles - 3 wire Selection Guide eurofast® minifast® 1/2 - NPT FSV H4-*M / 14.5 RSFV H4-*M / 14.5 3/4 - NPT FSV H4-*M / 14.75 RSFV H4-*M / 14.75 M20 FSV H4-*M / M20 RSFV H4-*M / M20 * Indicates length in meters. For female receptacles change part number to (FKV, RKFV...). FSV H4-*M / 14.5 RSFV H4-*M / 14.5 FSV H4-*M / 14.75 RSFV H4-*M / 14.75 FSV H4 -*M / M20 RSFV H4-*M / M20 Female eurofast® Male minifast® 1. 2. 3. 4. 90 Blue (-Voltage) Brown (+ Voltage) N/C Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Conduit Adapter minifast® Schematic 2-port 2-port BCA 4H-E223 BCA 4HM-M123 BCA 4HM-E123 drop BCA 4H-M223 drop BCA 4HM-E223 drop BCA 4HM-M223 1-port trunk drop source trunk drop Description eurofast® The conduit adapter attaches to a standard conduit body for transition to minifast® or eurofast® connectors. • Gasket and mounting hardware included (8-32 x 1/2”) Pinout Dimensions 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) N/C Green/Yellow (Ground) CROUSE - HINDS Hub Size = 3/4 Shape Conduit Bodies Style Part Number C Form 8 Mark 9 C28 C29 LB Form 8 Mark 9 LB28 LB29 LL Form 8 Mark 9 LL28 LL29 LR Form 8 Mark 9 LR28 LR29 4 Conduit connectors for use with armorfast® cable O-Z Gedney JMC-50-71 1/2NPT InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 91 HAR T ® Multidrop T ees HART Tees Part Number Dimensions Description RSV 2RKV HM4 minifast® tee • data, ground, shield • stainless steel coupling nuts RSV FKV RKV HM4 minifast® to eurofast® drop • data, ground, shield • stainless steel coupling nuts For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...) For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...) Part Number Dimensions Description RSCV 2RKCV H4 eurofast® tee • stainless steel coupling nuts 92 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable multidrop® T ee Wireable Tee Description The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience. This allows an extremely rapid changeover to a connectorized network, often in less than 15 minutes. The Field Wireable IP67 Tee SPTTM13-AHM4 features standardized minifast® connectors for the drop connection and field wireable terminals on the trunk connections. This provides the best of both worlds, reliable connections on the short lengths and ease of installation planning on the long trunk runs. SPTTM13-AHM4 SPTT1-AHM4 Dimensions 4 W ir eT able ire Table Specifications Pin Designation Color 1 V- Blue 2 V+ Brown 3 Shield Bare 4 Ground Green/Yellow InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 93 Gender Changers and Elbow Connectors Part Number Dimensions Description RSV RSV H4 minifast® Male Gender Changer • female cordset to male receptacle RKV RKV H4 minifast® Female Gender Changer • male cordset to female receptacle WSV RKV H4 minifast® Elbow • right angle male to female connector RSM H4-FK 4.5 minifast® to eurofast® Adapter • minifast® male to eurofast® female connector • nickel-plated brass housing For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...) 94 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Bulkhead Feed-Thru Receptacles panel mount minifast® Bulkhead Receptacle • straight male/female feed thru RSFV RKF H4/22 For jam nuts or spare nuts order: LN-SS 1/2-14[10/BAG] or LN-SS12[10/BAG] 44 eurofast® Bulkhead Receptacle • straight male/female feed thru FKV FSV H4/M12 For nickel-plated brass coupling nuts change part number: RSFV RKFV H4/22 to RSF RKF H4/22 or FKV FSV H4/M12 to FKM FS H4/M12 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 95 Cable Leads Panel Mount Receptacles - minifast®, eurofast® Selection Guide Female Male minifast® RKFV H4 - *M RSFV H4 - *M eurofast® FKV H4 - *M FSV H4 - *M minifast® RKFV H40 - *M RSFV H40 - *M eurofast® FKV H40 - *M FSV H40 - *M * Indicates length in meters. RKFV H4 - *M RSFV H4 - *M FKV H4 - *M FSV H4 - *M Male eurofast® Female minifast® 1. 2. 3. 4. 96 Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Cable Leads Panel Mount Receptacles - multifast® Selection Guide Female Male 12-pin CKF H12 CSF H12 19-pin CKF H19 CSF H19 12-pin CKF H120 CSF H120 19-pin CKF H190 CSF H190 CKF .. or CSF .. CKF.. CSF.. 4 See page 85 for functional wiring diagram. Male Female Male Female 12-pin 12-pin 19-pin 19-pin InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 97 Field W ireable Connectors - minifast® Wireable Selection Guide Aluminum Stainless Steel Female B 4149-0/9 BV 4149-0/9 Male BS 4149-0/9 BSV 4149-0/9 Accepts 6-8mm cable (.236” - .315”) B 4149-0/9 BS 4149-0/9 BSV 4149-0/9 BV 4149-0/9 Male Female 1. 2. 3. 4. 98 Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Field W ireable Connectors - eurofast® Wireable Selection Guide Straight Right Angle Female B8141-0/PG9 B8241-0/PG9 Male BS8141-0/PG9 BS8241-0/PG9 Accepts 6-8mm cable (.236” - .315”) B8141-0/PG9 B8241-0/PG9 BS8141-0/PG9 BS8241-0/PG9 4 Housing Material PBT Coupling Nut Material - Female - nylon Male - nickel-plated brass Female eurofast® Male eurofast® 1. 2. 3. 4. Blue (-Voltage) Brown (+ Voltage) Bare (Shield Drain Wire) Green/Yellow (Ground) InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 99 Field W ireable Connectors - multifast® Wireable 12-pin* 19-pin** Female CK 12-0 CKV 19-0 Male CS 12-0 CSV 19-0 Selection Guide * Accepts 4-10mm cable (.157” - .394”) ** Accepts 5-12mm cable (.197” - .472”) CK.. CS.. Female contact holder, female threads Male contact holder, female threads See page 85 for functional wiring diagram. Female Male 12-pin 100 19-pin 12-pin 19-pin InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Closure Cap Closure caps are for unused ports on the junction box. Dimensions Description RKMV BC minifast® closure cap • mates to male receptacles • Stainless steel • IP67 rated RSMV BC minifast® closure cap • mates to female receptacles • Stainless steel • IP67 rated RSFK-BC (10/BAG) minifast® Closure Cap 4 • mates to female receptacles • nylon VZ-3 (8/BAG) eurofast® Closure Cap • mates to female receptacles • nylon InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 101 Index Symbols F 4MB12-40H-CS12 ............................................89 8MB12-40H-CS19 ............................................89 B 4148-0/9 .......................................................73 B 4149-09...................................................98, 44 B8141-0/PG9 .....................................99, 74, 45 B8241-0/PG9 ......................................99, 74, 45 BCA 48-E123 ...................................................65 BCA 48-E223 ...................................................65 BCA 48-M123 ..................................................65 BCA 48-M223 ..................................................65 BCA 49-E123 ...................................................35 BCA 49-E223 ...................................................35 BCA 49-M123 ..................................................35 BCA 49-M223 ..................................................35 BCA 4HM-E123 ................................................91 BCA 4HM-E223 ................................................91 BCA 4HM-M123 ...............................................91 BCA 4HM-M223 ...............................................91 BRPC-49-M213 ................................................40 BS 4148-0/9 .....................................................73 BS 4149-0/9 ..............................................98, 44 BS8141-0/PG9 ...................................99, 74, 45 BS8241-0/PG9 ...................................99, 74, 45 BSV 4148-0/9 ...................................................73 BSV 4149-0/9 ............................................98, 44 BV 4148-0/9 .....................................................73 BV 4149-0/9 ..............................................98, 44 FKV 48 - *M ...........................................................72 FKV 483 - *M .........................................................72 FKV 49 ...................................................................43 FKV 490 - *M .........................................................43 FKV FSV 48/M12 ....................................................71 FKV FSV 49/M12 ....................................................42 FKV FSV H4/M12 ...................................................95 FKV H4 - *M ...........................................................96 FKV H40 - *M .........................................................96 FOUNDATION fieldbus - Cable Specifications ........17 FOUNDATION fieldbus - Cable and Cordsets ...18-19 FSV 48 - *M ............................................................72 FSV 483 - *M ..........................................................72 FSV 48T-*M / 14.5 ..................................................62 FSV 48T-*M / 14.75 ................................................62 FSV 48T-*M / M20 ..................................................62 FSV 49 ...................................................................43 FSV 49-*M / 14.5 ....................................................32 FSV 49-*M / 14.75 ..................................................32 FSV 49-*M / M20 ....................................................32 FSV 490 - *M ..........................................................43 FSV 49T-*M / 14.5 ..................................................33 FSV 49T-*M / 14.75 ................................................33 FSV 49T-*M / M20 ..................................................33 FSV H4 - *M ...........................................................96 FSV H4-*M / 14.5 ...................................................90 FSV H4-*M / 14.75 .................................................90 FSV H4-*M / M20 ...................................................90 FSV H40 - *M .........................................................96 C H CK 12-0 ..........................................................100 CKF H12.............................................................97 CKF H120 .........................................................97 CKF H19 ...........................................................97 CKF H190 ..........................................................97 CKV 19-0 ........................................................100 Connector Specifications ....................................7 CS 12-0 ..........................................................100 CSF H12 ...........................................................97 CSF H120 .........................................................97 CSF H19 ...........................................................97 CSF H190 .........................................................97 CSV 19-0 ........................................................100 HART - Cable Specifications ..................................79 HART - Cables and Cordsets ......................80-81, 84 B J JBBS-48-E413 .......................................................60 JBBS-48-E613 .......................................................60 JBBS-48-E813 .......................................................60 JBBS-48-M413 ......................................................58 JBBS-48-M613 ......................................................58 JBBS-48-M813 ......................................................58 JBBS-49-E413 .......................................................30 JBBS-49-E613 .......................................................30 JBBS-49-E813 .......................................................30 JBBS-49-M413 ......................................................28 E eurofast® Part Number Keys ...............................9 120 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 Index JBBS-49-M613 .................................................28 JBBS-49-M813 .................................................28 JTBS-40H-CS12 ...............................................86 JTBS-48SC-M633 .............................................56 JTBS-49-I633 ....................................................26 JTBS-49SC-M633 .............................................24 JTBS-60HM-RS4 ..............................................86 JTBS-70H-CS19 ...............................................86 JTBS Part Number Key .....................................11 M Marine Cable .....................................................22 minifast® Part Number Keys ..............................10 P PROFIBUS-PA - Cable Specifications ................51 PROFIBUS-PA - Cables and Cordsets .........52-53 R RKFV 48 - *M ....................................................72 RKFV 483 - *M ..................................................72 RKFV 49 ............................................................43 RKFV 490 - *M ..................................................43 RKFV H4 - *M ....................................................96 RKFV H40 - *M ..................................................96 RKGV-* ..............................................................23 RKMV BC ..........................................101, 75, 46 RKV RKV 48 ......................................................68 RKV RKV 49 ......................................................38 RKV RKV H4 .....................................................94 RSCV 2RKCV 48 ...............................................66 RSCV 2RKCV 49 ...............................................36 RSCV 2RKCV H4 ..............................................92 RSEV 48-TR ......................................................63 RSEV 48-TR-Ex .................................................64 RSEV 49-TR ......................................................34 RSFK-BC (10/BAG) ...........................101, 75, 46 RSFV 48 - *M ....................................................72 RSFV 483 - *M ..................................................72 RSFV 48T-*M / 14.5 ..........................................62 RSFV 48T-*M / 14.75 ........................................62 RSFV 48T-*M / M20 ..........................................62 RSFV 49 ............................................................43 RSFV 49-*M / 14.5 ............................................32 RSFV 49-*M / 14.75 ..........................................32 RSFV 49-*M / M20 ............................................32 RSFV 490 - *M ..................................................43 RSFV 49T-*M / 14.5 ..........................................33 RSFV 49T-*M / 14.75 ........................................33 RSFV 49T-*M / M20 ........................................33 RSFV H4 - *M .................................................96 RSFV H4-*M / 14.5 .........................................90 RSFV H4-*M / 14.75 .......................................90 RSFV H4-*M / M20 .........................................90 RSFV H40 - *M ...............................................96 RSFV RKF 48/22 .............................................71 RSFV RKF 49/22 .............................................42 RSFV RKF H4/22 ............................................95 RSGV-* ...........................................................23 RSM 48-FK 4.5 ...............................................68 RSM 49-FK 4.5 ...............................................38 RSM H4-FK 4.5 ................................................94 RSMV BC .........................................101, 75, 46 RSV 2RKV 48 ..................................................66 RSV 2RKV 49 ..................................................36 RSV 2RKV HM4 ..............................................92 RSV 48-TR ......................................................63 RSV 48-TR-Ex .................................................64 RSV 49-TR ......................................................34 RSV FKV RKV 48 ............................................66 RSV FKV RKV 49 ............................................36 RSV FKV RKV HM4 .........................................92 RSV RKV 48 SS ..............................................69 RSV RKV 49 SS ..............................................39 RSV RSV 48 ....................................................68 RSV RSV 49 ....................................................38 RSV RSV H4 ...................................................94 S SHLD, EURO ............................................70, 41 SHLD, EURO FW ......................................70, 41 SHLD, MINI ...............................................70, 41 SHLD, MINI FW ........................................70, 41 SPTT1-A48 ......................................................67 SPTT1-A49 ......................................................37 SPTT1-AHM4 ..................................................93 SPTTM13-A48 .................................................67 SPTTM13-A49 .................................................37 SPTTM13-AHM4 .............................................93 V VBM-40H-CS12 ..............................................88 VBM-80H-CS19 ..............................................88 VZ-3 (8/BAG) ...................................101, 75, 46 W WSV RKV 48 ...................................................68 WSV RKV 49 ...................................................38 WSV RKV H4 ..................................................94 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 6 121 V isit us at www .interlinkbt.com www.interlinkbt.com * Link to support.interlinkbt.com Web Site Featur es: Features: What’ s New: What’s Pr oducts: Products: Sear ch: Search: Tech Support: Calendar: Literatur e: Literature: Contacts: About Us: Login: 122 Check the latest articles, literature updates and product releases. Complete listing of network cables and cordsets, interconnection products, accessories, I/O stations and modules, I/O systems and more. Use keywords and phrases to locate specific information. See page 123. Check out the events in your area. Contains a complete listing of catalogs, brochures, tutorials, CAD drawings and electronic news releases from InterlinkBT®. Download pdf files or register for mail copy. Sales - Find reps and distributors in your area. Partners - Lists affiliates and trade associations. Integrators - Contains business summaries and web site links. Us - Submit requests and comments directly to InterlinkBT®. Contains company information and opportunities. The login page provides access to the secure area for the InterlinkBT® sales channel. InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 V isit us at support.interlinkbt.com * Click Tech Support from interlinkbt.com or visit support.interlinkbt.com Technical Support W eb Site Featur es: Web Features: App. Notes: CAD Library: Config. Files: Documents: Softwar e: Software: Application Notes contain documents for approvals and testing, mapping and configuration and application guidelines. Contains Product CAD Files - search by network and/or part number. EDS and GSD file search. Download catalogs, guides, manuals and wiring diagrams. Lists software that is available for download. 6 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 123 Warranty InterlinkBT, LLC (hereinafter “InterlinkBT”) warrants the Products covered by this WARRANTY AGREEMENT to be free from defects in material and workmanship under normal and proper usage for 18 months from the date of shipment from InterlinkBT. THE WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER REPRESENTATIONS MADE – BOTH EXPRESSED AND IMPLIED. THERE ARE NO WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR PRODUCTS COVERED BY THESE TERMS AND CONDITIONS. InterlinkBT warrants that the goods sold are as described, but no promise, description, affirmation of fact, sample model or representation, oral or written shall be part of an order, unless set forth in these terms and conditions, or are in writing and signed by an authorized representative of InterlinkBT. This warranty does not apply to any Product which has been subject to misuse, negligence, or accident – or to any Product which has been modified or repaired, improperly installed, altered, or disassembled – except according to InterlinkBT’s written instructions. This WARRANTY is subject to the following conditions: 1. 2. 3. 4. This WARRANTY is limited to the electronic and mechanical performance only, as expressly detailed in the Product specifications and NOT to cosmetic performance. This WARRANTY shall not apply to any cables attached to, or integrated with the Product. However, the 18 month warranty shall apply to cables sold separately by InterlinkBT. This WARRANTY shall not apply to any products which are stored, or utilized, in harsh environmental or electrical conditions outside written specifications. The WARRANTY is applicable only to Products shipped from InterlinkBT subsequent to May 1, 1998. Purchaser’s Remedies If an InterlinkBT Distributor desires to make a WARRANTY Claim, the Distributor shall, if requested by InterlinkBT, ship the Product to InterlinkBT’s facility in Minneapolis, Minnesota, postage or freight prepaid. If the User desires to make a WARRANTY Claim, they shall notify the authorized InterlinkBT Distributor from whom it was purchased or, if such Distributor is unknown, shall notify InterlinkBT. InterlinkBT shall, at its option, take either of the following two courses of action for any products which InterlinkBT determines are defective in materials or workmanship. 1. 2. Repair or replace the Product and ship the Product to the Original Purchaser or to the authorized InterlinkBT Distributor, postage or freight prepaid; or Repay to the Original Purchaser that price paid by the Original Purchaser. PURCHASER’S REMEDIES SHALL BE LIMITED EXCLUSIVELY TO THE RIGHT OF REPLACEMENT, REPAIR OR REPAYMENT AS PROVIDED AND DOES NOT INCLUDE ANY LABOR COST OR REPLACEMENT AT ORIGINAL PURCHASER’S SITE. INTERLINKBT SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF ANY WARRANTY, EXPRESSED OR IMPLIED, APPLICABLE TO THE PRODUCT, INCLUDING WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM PROPERTY DAMAGE, PERSONAL INJURY OR BUSINESS INTERRUPTION. Risk of Loss Delivery of the equipment to a common carrier shall constitute delivery to the Purchaser and the risk of loss shall transfer at that time to Purchaser. Should delivery be delayed due to an act or omission on the part of the Purchaser, risk of loss shall transfer to the Purchaser upon notification by InterlinkBT that the order is complete and ready for shipment. Consider Safety and Protection Precautions InterlinkBT takes great care to design and build reliable and dependable products, however, some products can fail eventually. You must take precautions to design your equipment to prevent property damage and personal injury in the unlikely event of failure. As a matter of policy, InterlinkBT does NOT recommend the installation of electronic controls as a sole device FOR THE PROTECTION OF PERSONNEL in connection with power driven presses, brakes, shears and similar equipment and, therefore, the customer should build in redundancy or dual control using approved safety devices for these applications. Governing Law The sale and purchase of Products covered hereby and all terms and conditions hereof shall be governed by the law of the State of Minnesota. Product Availability InterlinkBT makes every effort to stock most of these part numbers in reasonable quantities. InterlinkBT also makes no guarantee of availability of any product represented. Some part numbers are available on a special order basis only and may require longer lead times. Please consult with InterlinkBT when you need a committed delivery date. Special Order Items Certain part numbers require minimum order quantities. As a general guideline, product not listed in this price list may be subject to 25 piece minimum order quantity. If there is any question on availability or minimum order quantities, please contact InterlinkBT before ordering. Field Service 124 Please contact InterlinkBT details. InterlinkBT 3000 Campus for Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 ®