Fieldbus Connectivity

advertisement
Fieldbus Connectivity
busstop® Overview
Connector Specifications
Pre-molded Fieldbus Cables
Part Number Keys
2
7
8
9
1
FOUNDATION™ Fieldbus Overview
Cable and Cordsets
Junctions (Bricks)
Device Glands
Terminating Resistors
Tees and Adapters
Surge Suppressor, Power Conditioner and Lokfast™ Guard
Receptacles
Field Wireables and Accessories
13
18
24
32
34
35
39
42
44
2
PROFIBUS®-PA Overview
Cable and Cordsets
Junctions (Bricks)
Device Glands
Terminating Resistors
Tees and Adapters
Surge Suppressor and Lokfast™ Guard
Receptacles
Field Wireables and Accessories
47
52
56
62
63
65
69
71
73
3
HART® Overview
Cable and Cordsets
Junctions
Device Glands
Tees and Adapters
Receptacles
Field Wireables and Accessories
76
80
86
90
91
95
98
4
Installations
102
5
Index of Components
120
6
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
1
AW
orldwide Fieldbus Solution
Worldwide
Interlink
BT® - A Banner
-TURCK Bus Pr
oducts Company
InterlinkBT
Banner-TURCK
Products
InterlinkBT® is a joint venture between two renowned sensor companies, TURCK, Inc. and Banner Engineering, to
focus specifically on bus products. The experience and advanced bus technologies of these companies are now
combined, resulting in the industry’s broadest, most complete line of stations, junctions, cordsets and components
for device-level networks. InterlinkBT® is the industry’s bus I/O specialist and leading supplier of top-quality bus
products. Most importantly, InterlinkBT® is your best solution to connect input/output devices to open buses.
Interlink
BT
InterlinkBT
BT’’S Fieldbus Connectivity Catalog
This catalog covers high quality on-the-machine and at-the-process FOUNDATION™ fieldbus H1, PROFIBUS®-PA
and HART® interconnect products. The product offering emphasizes materials for diverse applications where
aggressive environments are often the norm.
Cable
InterlinkBT® has the products for interconnecting all your devices on a network segment. By simply plugging
components together these products allow for quick installations of new plant layouts and easy alterations to
existing installations. InterlinkBT’s junction blocks are rugged and can be mounted in aggressive environments.
Spur or drop count can vary from 4 to 8 with the choice of minifast® or eurofast® connector sizes.
InterlinkBT® cable exceeds ISA SP50.02 specifications for impedance and attenuation. Pre-molded cordsets are
available with either minifast® or eurofast® connector sizes. The easy-to-use terminating resistor simply screws
into the end of the Home Run cable. You can reliably use InterlinkBT® fieldbus products in the harshest of
environments.
2
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connectors
1
Not all the I/O in a fieldbus system can be connectorized, but when it can it is extremely effective. A few minutes of
layout and bill-of-material planning can replace hours of costly wire installation. In addition, product replacement is
greatly facilitated by using industrial grade quick disconnect plug-and-play receptacles.
InterlinkBT® uses two industrial standardized connectors. The generic names for them are “Mini” and “Micro” or “Euro”.
In one variation or another these two standardized connectors are produced by the thousands. Rough estimates put
the “Mini” style at over 10,000 per day and the “Euro” at over 25,000 per day. They are used in every industry that
requires rugged economic plug-and-play connectorization. Both were standardized by DIN (German Industrial Standards) in their early design. Today they are recognized standards throughout the world.
The sheer volume means that the build processes for these two standards are understood, tooled, automated and
economical. The volume and breadth of applications means that broad selections of off-the-shelf products are available.
There are three materials for coupling nuts; stainless steel, nylon and nickel-plated brass. The mating pin and sleeves
are gold-plated brass. The body is made of polyurethane and is injection molded to the cable jacket to provide strain
relief and to seal the connections from the atmosphere.
The Mini’s pin and sleeve are rated at 9 amps and the Micro is rated at 4 amps. The designated ground pin of the Mini
family is longer than the other pins, resulting in a make-first/break-last ground. This feature is not explicitly required for IS
or NI applications, but is a sound engineering choice. All the pins of the Euro make and break at the same time during
insertion and removal.
Junction Boxes
The junction boxes shown in this catalog are passive hubs. Although no conditioning or monitoring takes place,
some junctions have short circuit protection. This protects the power on the trunk and allows use in Class 1, Div 2
locations. The boxes are made from two different materials; copper-free die-cast aluminum with a powder coated
enamel finish or polyurethane overmold. Both housings are available with either 316 stainless steel or nickel plated
brass connectors.
The junction boxes are rated NEMA 1, 3, 4, 4X, 12, 13 and IEC IP67. These ratings are conditional, requiring the
cordset or cap to be installed. Although the die cast housing is rated 4X (salt-water spray test) we highly recommend
the polyurethane or fiberglass housing for aggressive environments.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
3
Occupants on the Bus
Active Hub - a multiple port repeater or amplifier that lengthens the branching ability of a bus.
Barrier Box - limits current/voltage to an area.
Brick - fully connectorized passive junction.
Bridge - there are two types; one is a double-sided node that connects two segments together that are the same
protocol but different transmission speeds, the other is a smart repeater that only repeats the data between two bus
segments when the source and destination address are in different segments. The bridge must be programmed to
know what the addresses are and their respective segments.
Bus Junction - generic name for a passive hub.
Busline - any group of wires that carries data from node-to-node.
Dr
opline - a reduced branch (spur) from a trunkline.
Dropline
Gateway - a special node on two different buses that serves as a signal and data translator between the buses.
LAS (Link Active Scheduler) - controls communication on the bus. Creates a token circulation list (Live List) that
defines access on the bus. Devices may only communicate when given access by the LAS unit. Multiple devices may
have LAS capabilities but only one can communicate at a time.
Node - an addressable device on the bus.
Power Conditioner - device used to condition the power to be for a bus segment. Allows power and data to exist
on the same wires.
Repeater - a product that strengthens a signal, while adding up to a half-bit wait state and producing a fresh signal
without distortions. It also links two portions of the same bus together. A repeater is used when a signal is weak or
distorted.
Router - a higher level bridge for connection of wide area networks.
Simple Device - anything that does not have LAS capabilities.
Tee
System T
ee - a field wireable tee.
Tee - a product that creates a branch or drop from a bus.
esistor - a resistor that is put at the beginning and end of the main busline to stabilize and minimize
Terminating rresistor
reflections.
Trunk line - the main busline.
To Control Highway
Fieldbus I/O Host
24V
24V
Main Trunk Cable
Main Trunk Cable
Terminator
Spurs
BRPS-49-M213
JTBS-49SC-M633
Pressure Transmitter
4
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Bus T
opology
Topology
Topology is a term that applies to buses. It describes how the data lines connect the nodes together. The first bus
goes back to the original telegraph - two data lines hanging on wooden poles going from telegraph station to
telegraph station.
1
Bus - the simple straight-line topology is called a bus. Another term used is “Daisy Chain”, where the trunk simply
runs from device to device.
Branch - a common bus can have branches, and sometimes the branches can have branches. Another term
used to describe the branches is “drops” or “spurs”, as in FOUNDATION™ fieldbus. Depending on the bus the
branches may be restricted to just a few centimeters or a free-form topology with restrictions only on the
cumulative distance of all data lines.
Star - the bus lines radiate from a single point. A junction (either passive or active) looks like a star. FOUNDATION™
fieldbus also refers to this as a “chicken foot” topology with many branches connected in a relatively small area.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
5
Bus T
ypes
Types
There are several different bus types utilizing the following technologies:
Client / Server - upload/download information, setpoint changes, alarm management, remote diagnostics and one to
one communications.
Media Access - this is the “right-of-way” for talking on the bus. There are three main types:
Master Control - one super node controls all transmission, sequence and time. Remaining nodes do not talk
unless told to by the master.
Token Passing - this is a message shift method that is incremented in a manner that allows each node a chance
to talk during each cycle.
CSMA - an access method allowing each node to speak, provided that it has something to say and no other node
is talking on the line.
Message Collision A
voidance - when two people talk simultaneously there is a verbal collision. A few humans can
Avoidance
talk and listen to someone else at the same time but nodes cannot. Both token passing and master control do not
have that problem. A field node can only access the bus when it is its turn to talk or when it has been told to talk.
CSMA-type buses do have this problem. The problem goes away when they are operated as a master-to-slave.
When operating in the native CSMA access method two nodes could start talking simultaneously. Two major ways
have been developed to handle a potential collision:
CD - collision detection - all senders must also be receivers. If two nodes start talking at the same time they will
hear a collision. Both stop talking, wait a random length of time, then look for a clear line to start talking
again.
BA - bitwise arbitration - all senders must also be receivers. The busline must be of a specific length or less so
that all nodes hear the bit at the same time (actually the first node and the last node can be approximately
1/6 bit apart).
Messaging - there are three major types in the run mode, but many more during start-up and initialization.
Solicited - a response to another node or a response when it is the node’s predetermined time to speak
(token passing).
Unsolicited - a response to a change-of-state at the node.
Explicit - a command order. It may command an output be turned “On” or “Off”. It may command any node
to report its diagnostic status or identity itself in full detail.
One last distinction must be made for the output nodes. How do they get the information so they know what to do?
Although there is an overlap with the terms used for messaging, there are important differences:
Explicit Message - this is a command from another node.
Limited Peer
-to-Peer - exclusive one-to-one relationship between the input node and the output node. This could
Peer-to-Peer
also be called exclusive peer-to-peer.
Unlimited Peer
-to-Peer - similar to limited peer-to-peer, but the output node may get information from several input
Peer-to-Peer
nodes.
Publisher / Subscriber - scheduled distribution of data to nodes on the subscriber list.
6
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connector Specifications
minifast® Connector
- 7/8” - 16UNF thread
-100% electrically tested
-Meets: SAE H1738-2
-Current Rating: 9A
-Voltage Rating: 300V
-Protection: NEMA 1,3,4,6P IEC IP67
-NEMA 4X with stainless steel coupling nuts
-Temperature: -30ºC to +85ºC
-Oscillation: 65mm (2.5in.) to 125mm (5in.)
-Pull Strength: 100 lbs - 5 to 12.5 cycles/sec. for 2 million
cycles
eurofast® Connector
-M12 x 1 thread
-100% electrically tested
-Meets: IEC 61076
-Current Rating: 4A
-Voltage Rating: 300V
-Protection: NEMA 1,3,4,6P and IEC IP67
-NEMA 4X with stainless steel coupling nuts
-Temperature: -30ºC to +85ºC
-Vibration: 10 to 500 Hz and 0/35mm or 5g
-Pull Strength: 50 lbs
1
multifast® Connector
- M23 x 1 thread
-100% electrically tested
-Current Rating: 4A
-Voltage Rating: 300V
-Protection: NEMA 1,3,4,6P IEC IP67
-Temperature: -30ºC to +85ºC
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
7
Pr
e-molded Fieldbus Cables
Pre-molded
Pre-molded fieldbus cables ensure simple and secure wiring of the connected fieldbus components. Time-consuming wiring
of individual components and bus communication problems due to wiring errors or incomplete shielding are eliminated.
Molded polyurethane insulation provides IP67 protection.
Standard lengths of pre-molded cordsets and bulk cable are listed below. Consult the factory for other lengths.
Standar
d Cable Lengths
Standard
Cordsets
Bulk Cable
meters
feet
0.3
1.0
0.5
1.6
1.0
3.3
1.5
4.9
2.0
6.6
2.5
8.2
3.0
9.8
4.0
13
5.0
16
6.0
20
8.0
26
10
33
15
49
20
66
25
82
30
98
40
131
50
164
meters
feet
30
98
75
246
150
492
225
738
300
984
---
---
Other lengths available upon request.
Unit Conversions:
1 meter = 3.28 feet
1 meter = 39.79 inches
8
Tolerances:
+50/-0 mm or +4% of length which ever is greater
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Part Number Keys
Cor
dsets
Cordsets
R
S C
49x
V
1
*M
Length in Meters (*)
Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8)
Consult factory for other lengths
R = Straight
W = Right Angle
Gender
S = Male Connector
K = Female Connector
Cable T
ype (x)
Type
48x (see page 51)
49x (see page 17)
H4x (see page 79)
Designator for eurofast®
Coupling Nut Material
V
= Stainless Steel
(Blank) = Nickel-Plated Brass
Receptacles
F
Designator for eurofast®
Gender
S = Male Connector
K = Female Connector
S F
V
49x
*M
Length in Meters (*)
Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8)
Consult factory for other lengths
Cable T
ype (x)
Type
48x (see page 51)
49x (see page 17)
H4x (see page 79)
Designator for Receptacles
Coupling Nut Material
V
= Stainless Steel
(Blank) = Nickel-Plated Brass
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
9
minifast® Part Number Keys
Cor
dsets
Cordsets
W
K
4 9x
M
*M
Length in Meters (*)
Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8)
Consult factory for other lengths
R = Straight
W = Right Angle
Gender
S = Male Connector
K = Female Connector
Cable T
ype (x)
Type
48x (see page 51)
49x (see page 17)
H4x (see page 79)
Coupling Nut Material
M
= Nickel-Plated Brass
V
= Stainless Steel
(Blank) = PA 6.6 (Nylon)
Receptacles
R
K
F
V
4 9x
*M
Length in Meters (*)
R = Straight
Gender
S = Male Connector
K = Female Connector
Standard 0.3, 0.5, 1, 1.5, 2 ....(see page 8)
Consult factory for other lengths
Cable T
ype (x)
Type
48x (see page 51)
49x (see page 17)
H4x (see page 79)
Designator for Receptacles
Coupling Nut Material
V
P
10
= Stainless Steel
= Nickel-Plated Brass
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Junction T
ee Part Number Key
Tee
JT
B
S
49
SC
M
6
3
3
1
Connector Material
3 = Stainless Steel
4 = Nickel-Plated Brass
Housing
1 = Aluminum (JBBS only)
2 = Fiberglass (JBBS only)
3 = Polyurethane (JTBS only)
4 = Hytrel (JTBS only)
JT = Junction Tee
JB = Junction Box
Number of Ports
4 = 4 ports
6 = 6 ports
8 = 8 ports
Bus System
48 = PROFIBUS®-PA
49 = FOUNDATION™ fieldbus
Connector T
ype
Type
®
minifast
M =
®
eurofast
E =
Pr
otection
Protection
SC
= Short Circuit
(Blank) = None
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
11
For HART® Systems Only
H AR
T ® Junction Box Part Number Key
ART
V
B
Housing
VBM
- Metal Housing
eurofast® Connectors
4MB12 - Nylon Housing
or
eurofast® Connectors
8MB12
JTBS
- Polyurethane Housing
minifast® Connectors
Number of Ports
40 - 4 ports
60 - 6 ports
70 - 7 ports
80 - 8 ports
12
M
4
0
H
C
S
V
1
2
Home Run Connector
CS12 - multifast® 12-pin
CSV12* - multifast® 12-pin
CSV19* - multifast® 19-pin
CS19 - multifast® 19-pin
- minifast® 5-pin
RS
RSV* - minifast® 5-pin with
*stainless steel coupling nut
HAR
T® T
opology
ART
Topology
H - HART® Point-to-Point
HM - HART® Multidrop
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
1
FOUNDA
TION™ fieldbus Cables and Accessories
OUNDATION
2
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
13
FOUNDA
TION™ fieldbus Overview
OUNDATION
FOUNDATION™ fieldbus is a communication protocol and defined physical method to interconnect smart devices
such as temperature transmitters, pressure transmitters and valve actuators. The physical layer conforms to ISA
SP50.02 and IEC 1158-2 standards for fieldbuses. In comparison to 4-20 mA loops that only allow for one device
connection per twisted pair, fieldbus technology enables many smart devices to share one communication
medium. The digital communication signal is superimposed onto a DC carrier. This greatly reduces the amount of
terminations needed to connect all the field devices to a host system. It also allows greater flexibility for future
additions of I/O points.
A FOUNDATION™ fieldbus device is addressable and has capabilities to store and transmit data. The devices can
store values, track changes and use pre-set alarms to trigger. Based on pre-defined tag names, host systems can
read transmitter values such as temperature and pressure or set values of a valve actuator.
The digital signal encoding is done using Manchester BiPhase-L and error checking is done with the CRC
method. FOUNDATION™ fieldbus has two types of devices; a Basic Device (BD) and a Link Active Scheduler (LAS).
A Basic Device is designed to read inputs, track values and set outputs if programmed to do so. A LAS device
performs the same features as a BD, however it goes one step further by handling network communication timing
between all the active devices on the network. The LAS essentially creates a time table so that all devices can get
a chance to transmit/receive data on the bandwidth. A fieldbus segment can have many Basic Devices but must
have at least one Link Active Scheduler. At least two LAS devices are recommended on the network to provide
redundancy. If there is more than one LAS on the network, the one that powers-up first gets the LAS designation
and the other LAS unit switches to BD mode of operation.
General Layout T
opologies
Topologies
e 1 for an example. All transmitters
In essence, all devices on a fieldbus segment are connected in parallel. See Figur
Figure
connected to the fieldbus segment listen to all communication signals, however the protocol determines the rules as
to which devices respond to the messages. For the purpose of this guide only the physical layout will be discussed
in detail. The general layout is either a star (chicken foot) or daisy chain.
93.3FM
1
2
3
4
5
Figure11- Parallel
WiringDiagram
Diagram
Figure
Parallel Wiring
Communication Signal
The FOUNDATION™ fieldbus H1 communication signal is a square waveform superimposed on a DC carrier. The
frequency of the signal is 31.25Khz. Although they do not have to, most devices derive their supply power from
the fieldbus communications cable. The fieldbus specification states that devices must not be polarity sensitive. It
is good electrical practice though to have all devices wired with the same polarities. The voltage range allowed for
proper operation is 9-32 VDC. A typical fieldbus device will consume 20 mA of current.
14
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Star T
opology Method
Topology
A star topology has a central connection point for all terminations. This layout works well when there are many
devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker
tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the
fieldbus segment. The best design would be to connect them all to a junction brick and then run a home run cable
e 2 for a pictorial example.
from the junction brick back to the control room. See Figur
Figure
The Home Run cable is considered the main trunk line for communication. Each device that is connected to the
junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line.
2
Figure 2 - Star Topology Example
Daisy Chain Configuration
In a daisy chain configuration each device would require a tee so that the Home Run cable would be able to go to
each device. From a design standpoint, the Daisy Chain method is easiest to do when the exact cable tracks are
e 3 for an
known. Pre-made cordsets can then be purchased, making the network easy to assemble. See Figur
Figure
example drawing. A fieldbus transmitter is connected to each of the tanks in the field. The Home Run cable
essentially is routed to each device in series.
Transmitters
Figure 3 - Daisy Chain Layout
In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. The key to the
wiring design is to make layouts valid per the fieldbus specifications. One of the benefits to fieldbus is reduced
wiring of devices, leading to faster start-up times.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
15
Fieldbus Cable Specifications
The specifications for fieldbus H1 physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2 Physical
Layer Standards. The same standard is also listed in the FOUNDATION™ fieldbus specifications under 31.25 Kbps
Physical Layer Profile FF-816-1.4. There are essentially four types of cable designations for fieldbus. Type A cable is
the most preferred for new installations because it allows for the most versatile lengths. The other types of cable are
able 1.
for installations where cable already exists from 4-20 mA systems. See T
Table
Type
Cable Description
Conductor Size
Maximum Length
Type A
Shielded, Twisted Pair
# 18 Awg
1900 m (6232 ft)
Type B
Shielded, Multi Twisted Pair
# 22 Awg
1200 m (3936 ft)
Type C
Unshielded, Multi Twisted Pair
# 26 Awg
400 m (1312 ft)
Type D
Shielded, Untwisted Pair
# 16 Awg
200 m (656 ft)
Table 1 - Fieldbus Cable Specifications
InterlinkBT® offers cables with both two conductors and three conductors, with the third conductor available for a
centralized ground of devices if needed. InterlinkBT® cables meet or exceed the specifications of ANSI/ISA-SP50.021992, the fieldbus standard for use in industrial control systems.
The maximum spur length is determined by the number of devices in the segment.
Cable
Trunk
1900 m
16
Number of Devices
Maximum Spur Length
25-32
0 m (0 ft)
19-24
30 m (98 ft)
15-18
60 m (197 ft)
13-14
90 m (295 ft)
2-12
120 m (394 ft)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
F OUNDA
TION™ fieldbus - Cable Specifications
OUNDATION
Our cable meets the requirements of ISA/SP50
and FOUNDATION™ fieldbus requirements for Type
A cable. Cables are available in 3-wire versions
with a device ground or 2-wire versions.
1
2
Cable Specifications
Type A Cable
- Temperature range: -40 to 105°C (-40 to +221F)
11
- Governed by: ISA SP50.02 specification
- Sunlight resistant
- PLTC and ITC rated (CSA FT4)
- Impedence[Z0 at fr (31.25 kHz)] = 100Ω ± 20%
- Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km
- Maximum capacitive unbalance to shield = 2 nF/km
- Maximum DC resistance (per conductor) = 24 Ω/km
- Maximum propagation delay variance 0. 25 fr to 1.25 fr = 1.7 µs/km
- Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG)
or 1.2 mm2 (#16 AWG)
- Minimum shield coverage shall be 90%
Data Pair
AWG
DCR (/1000 ft)
Color Code
Insulation
Outer Jacket
Material Color
Nominal O.D.
Shields
Type
Drain Wire
18 AWG
Green/Yellow
PVC Yellow
7.9mm (.310 in)
Foil
20 AWG
RB50693-*M
1
6.5 Ohms
PE
18 AWG
Green/Yellow
PVC Blue
7.9mm (.310 in)
Foil
20 AWG
RB50783-*M
1
NEC ITC PLTC/CM 2/18 AWG
CEC[CMG HLBCD] Blue/Brn
CEC
6.5 Ohms
PE
18 AWG
Green/Yellow
Armor/PVC Yellow
12.7mm (0.5 in)
Foil
18 AWG
RB50874-*M
11
NEC ITC PLTC/CM 2/18 AWG
CEC[CMG HLBCD] Blue/Brn
CEC
6.5 Ohms
PE
18 AWG
Green/Yellow
Armor/PVC Blue
12.7mm (0.5 in)
Foil
18 AWG
RB50803-*M
11
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Yellow
7.9mm (.310 in)
Foil/Braid
20 AWG
RB50784-*M
1
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Blue
7.9mm (.310 in)
Foil/Braid
20 AWG
RB50786-*M
1
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Orange
7.9mm (.310 in.)
Foil/TC Braid
20 AWG
RB50785-*M
1
NEC ITC PLTC
CEC [CMG]
2/16 AWG
Blue/Brn
4.3 Ohms
PE
None
PVC Yellow
8.5mm (.335 in.)
Foil
20 AWG
RB50891-*M
1
Type
Approvals
490
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
105°C 300V
490B
105°C 300V
492A
105°C 300V
492BA
105°C 300V
493
105°C 300V
493B
105°C 300V
493O
105°C 300V
496
105°C 300V
Device Ground
AWG Color Code
Bulk Cable Ref.
Part No.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
17
F OUNDA
dsets
TION™ fieldbus - Cable and Cor
Cordsets
OUNDATION
Pin (Male)
www.interlinkbt.com
eurofast®
minifast® †
Try Cordset Builder Online!
RSV
WSV
Pin (Male)
Socket (Female)
RKV
RSCV
WKV
RSV 49x -*M
WSV 49x -*M
RKV 49x -*M
WKV 49x -*M
RSCV 49x -*M
RSV RSV 49x -*M
RSV WSV 49x -*M
RSV RKV 49x -*M
RSV WKV 49x -*M
RSV RSCV 49x -*M
WSV WSV 49x -*M
WSV RKV 49x -*M
WSV WKV 49x -*M
WSV RSCV 49x -*M
RKV RKV 49x -*M
RKV WKV 49x -*M
RKV RSCV 49x -*M
WKV WKV 49x -*M
WKV RSCV 49x -*M
Pin (Male)
RSV
WSV
Socket (Female)
minifast®
†
Bare
RKV
×
*
†
Pin (Male)
RSCV RSCV 49x -*M
RSCV
WSCV
Socket (Female)
eurofast®
WKV
RKCV
WKCV
Indicates cable type.
Indicates length in meters.
Consult factory for availability of armorfast® with eurofast® connectors.
armorfast® cable only - straight only.
For nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
Bulk cable, see page 8 for standard lengths.
Example
18
WSV RSCV 490-1M
1 METER
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
FOUNDA
dsets
TION™ fieldbus - Cable and Cor
OUNDATION
Cordsets
eurofast®
Pin (Male)
WSCV
minifast®
Socket (Female)
RKCV
WKCV
Pin (Male)
RSFPV
Socket (Female)
RKFPV
eurofast® bulkhead
Pin (Male)
FSFDV
Socket (Female)
2
FKFDV
WSCV 49x -*M
RKCV 49x -*M
WKCV 49x -*M
RSFPV 49x -*M
RKFPV 49x -*M
FSFDV 49x -*M
FKFDV 49x -*M
RSV WSCV 49x -*M
RSV RKCV 49x -*M
RSV WKCV 49x -*M
RSV RSFPV 49x -*M
RSV RKFPV 49x -*M
RSV FSFDV 49x -*M
RSV FKFDV 49x -*M
WSV WSCV 49x -*M
WSV RKCV 49x -*M
WSV WKCV 49x -*M
WSV RSFPV 49x -*M
WSV RKFPV 49x -*M
WSV FSFDV 49x -*M
WSV FKFDV 49x -*M
RKV WSCV 49x -*M
RKV RKCV 49x -*M
RKV WKCV 49x -*M
RKV RSFPV 49x -*M
RKV RKFPV 49x -*M
RKV FSFDV 49x -*M
RKV FKFDV 49x -*M
WKV WSCV 49x -*M
WKV RKCV 49x -*M
WKV WKCV 49x -*M
WKV RSFPV 49x -*M
WKV RKFPV 49x -*M
WKV FSFDV 49x -*M
WKV FKFDV 49x -*M
RSCV WSCV 49x -*M
RSCV RKCV 49x -*M
RSCV WKCV 49x -*M
×
RSCV RSFPV 49x -*M
RSCV RKFPV 49x -*M
RSCV FSFDV 49x -*M
RSCV FKFDV 49x -*M
WSCV WSCV 49x -*M
WSCV RKCV 49x -*M
WSCV WKCV 49x -*M
WSCV RSFPV 49x -*M WSCV RKFPV 49x -*M
WSCV FSFDV 49x -*M
WSCV FKFDV 49x -*M
RKCV RKCV 49x -*M
RKCV WKCV 49x -*M
RKCV RSFPV 49x -*M
RKCV RKFPV 49x -*M
RKCV FSFDV 49x -*M
RKCV FKFDV 49x -*M
WKCV WKCV 49x -*M
WKCV RSFPV 49x -*M
WKCV RKFPV 49x -*M
WKCV FSFDV 49x -*M
WKCV FKFDV 49x -*M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
19
minifast® Cor
dset and Receptacle Connector Dimensions and Pinouts
Cordset
RSV
-*
RSV-*
RKV
-*
RKV-*
WKV-*
WSV
-*
WSV-*
RSFPV
-*
RSFPV-*
RKFPV
-*
RKFPV-*
Male
Mounting Installation
Female
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
Pinouts according to CENELEC EN 50 044 numbering convention.
Bracket dimensions are in [inches].
20
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Cor
dset and Receptacle Connector Dimensions and Pinouts
Cordset
RSCV
-*
RSCV-*
RKCV
-*
RKCV-*
2
WSCV
-*
WSCV-*
WKCV
-*
WKCV-*
FSFDV
-*
FSFDV-*
FKFDV
-*
FKFDV-*
Male
Mounting Installation
Female
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
21
InterlinkBT offers a full line
of connectors approved by
DNV and ABS.
Marine Cable - Specifications
New FOUNDATION™ fieldbus cables that are
UL1309 and CSA 222 No. 245 approved.
•
•
•
•
•
•
Type
4910
UL1309
4911
UL1309
Approvals
Device Ground
Data Pair
AWG
DCR (/1000 ft)
AWG Color Code
Color Code
Insulation
Outer Jacket
Material Color
Nominal O.D.
Shield/Armor
Type
Drain Wire
Bulk Cable
Part No.
IEEE 1202/FT4
2/18 AWG
IEEE 45-1998
Blue/Brn
IEEE 1580-2001 x 90
6.5 Ohms
XL PE
18 AWG
Green/Yellow
TPE / Black
8.9mm (.350 in)
Foil
20 AWG
RB51047-*M
IEEE 1202/FT4
2/18 AWG
IEEE 45-1998
Blue/Brn
IEEE 1580-2001 x 90
6.5 Ohms
XL PE
18 AWG
Green/Yellow
TPE / Black
12.7mm (.500 in)
TC Braid
20 AWG
RB51048-*M
Drilling Muds
• Water Based
• Synthetic Based
• Diesel Based
• Mineral Oil Based
22
Highly flame retardant, IEEE 1202/FT4 and IEC 332-3 Category A
Meets cold bend at -55° C (-67° F)
Meets cold impact at -50° C (-58° F)
Excellent moisture and oil resistance
Excellent cut through and abrasion resistance
Sunlight resistant
extremelife-130™ cables have been
extensively tested in various drilling
muds/fluids. The extremelife-130
cables, with their exclusive arcticlife
jacket materials, were compared with
the industry standard neoprene
cables. All tested cables passed the
tensile strength and elogation tests.
The extremelife-130™ cables proved
to be much more stable in size through
the tests when compared to the
neoprene jacketed cables.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Heavy Duty Cor
dsets
Cordsets
To meet the needs of the most
demanding applications, use the
heavy duty cordset. The long, heavy
coupling nut completely supports
the molded plug body to provide
superior strength.
2
Extensive field and lab testing of the
RKG style exceed SAE H1738-2 requirements - right angle
pull force tested to over 200 lbs!
RSGV
-*
RSGV-*
RKGV
-*
RKGV-*
* For nickel-plated brass coupling nut RSGV... to RSG...
RKGV... to RKG...
Male
Female
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
23
Short Circuit minifast® Junction T
ee
Tee
SC models only
Description
The FOUNDATION™ fieldbus junction tee is available with short circuit protection
and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically rugged,
the new overmolded design provides unparalleled corrosive resistance.
JTBS-49SC-M633
4-Pin Male
P1
4-Pin Female
S0-S6
Dimensions
MOUNTING SCREW
1/4” (2)
NOT INCLUDED
Short Circuit Protection (only available with SC models)
Electrical
•
Short Circuit Protection: 55mA (Isc)
•
Voltage Open Circuit: 35VDC
•
Current Consumption: 5mA
Specifications
Diagnostic
•
LED Indication:
Green LED - Bus Power; P1 and S0 only
Red LED - Short Circuit Indication
Cl 1, Div 2; Groups A-D
see InterlinkBT® drawing N1-2.400
T6, Ta = 70°C
24
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Short Circuit Protected
Connector Size
Connector Material
Part Number
Number of Ports
Overmold Material
Quick Selection Guide
JTBS-49-M433
4
mini
polyurethane
stainless steel
No
JTBS-49-M434
4
mini
polyurethane
nickel-plated brass
No
JTBS-49-M633
6
mini
polyurethane
stainless steel
No
JTBS-49-M634
6
mini
polyurethane
nickel-plated brass
No
JTBS-49SC-M433
4
mini
polyurethane
stainless steel
Yes
JTBS-49SC-M434
4
mini
polyurethane
nickel-plated brass
Yes
JTBS-49SC-M633
6
mini
polyurethane
stainless steel
Yes
JTBS-49SC-M634
6
mini
polyurethane
nickel-plated brass
Yes
JTBS-49-E433
4
euro
polyurethane
stainless steel
No
JTBS-49-E434
4
euro
polyurethane
nickel-plated brass
No
JTBS-49-E633
6
euro
polyurethane
stainless steel
No
JTBS-49-E634
6
euro
polyurethane
nickel-plated brass
No
JTBS-49SC-E433
4
euro
polyurethane
stainless steel
Yes
JTBS-49SC-E434
4
euro
polyurethane
nickel-plated brass
Yes
JTBS-49SC-E633
6
euro
polyurethane
stainless steel
Yes
JTBS-49SC-E634
6
euro
polyurethane
nickel-plated brass
Yes
JTBS-49SC-IE433
4
idc
polyurethane
stainless steel
Yes
JTBS-49SC-IM633
6
idc/mini
polyurethane
nickel-plated brass
Yes
JTBS-49SC-IE633
6
idc/euro polyurethane
stainless steel
Yes
JTBS-49SC-IM433
4
idc/mini
nickel-plated brass
Yes
polyurethane
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
2
25
Fieldwireable Junction T
ee
Tee
JTBS-49SC-I633
Description
JTBS-49SC-IM633
JTBS-49SC-IE633
The FOUNDATION™ fieldbus fieldwireable junction tee is available with short circuit
protection and is FM approved for Cl 1, Div 2 hazardous locations. Mechanically
rugged, the new overmolded design provides unparalleled corrosive resistance.
JTBS-49SC-I633
MOUNTING SCREW
1/4” (2)
NOT INCLUDED
Dimensions
Electrical
•
Short Circuit Protection: 55mA (Isc)
•
Voltage Open Circuit: 35VDC
•
Current Consumption: 5mA
Specifications
Diagnostic
•
LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
Cl 1, Div 2; Groups A-D
see InterlinkBT® drawing N1-2.400
T6, Ta = 70°C
Pending
26
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable Junction T
ee Assembly
Wireable
Tee
Consult factory for availability.
2
Description
Includes termination kit for each port.
1. Trim cable jacket 15-20mm
2. Place nut and seal onto cable. Seal should rest on cable jacket
3. Insert conductors in carrier
4. Trim conductors flush
5. Insert keyed carrier into port
6. Tighten back nut
Carrier
Connector Assembly
Seal
Nut
Termination kit
1.
2.
3.
4.
Pinouts
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
Trim Length
15-20mm
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
27
minifast® Passive Multiport Junctions (Bricks)
SC models only
Description
The junction box is available with short circuit protection and is FM Approved for
Cl 1, Div 2 hazardous locations. The rugged, fully encapsulated die-cast aluminum
enclosure is available with stainless steel connectors.
JBBS-49-M813
JBBS-49-M613
JBBS-49-M413*
Dimensions /
Part Number
* JBBS-49SC-M413 overall dimensions 7.3mm X 2.52mm
Short Circuit Protection (only available with SC models)
Electrical
•
Short Circuit Protection: 55mA(Isc)
•
Voltage Open Circuit: 35VDC
•
Current Consumption: 5mA
Applications
Diagnostic
•
LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
Cl 1, Div 2; Groups A-D
see InterlinkBT® drawing N1-2.400
T6, Ta = 70 degrees C
For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-49-M413 to JBBS-49-M414
For fiberglass housing change part number to -Mx2x. Example: JBBS-49-M613 to JBBS-49-M623
28
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connector Size
Housing Material
Short Circuit Protected
Part Number
Number of Ports
Connector Material
Quick Selection Guide
JBBS-49-M813
8
mini
aluminum
stainless steel
No
JBBS-49-M613
6
mini
aluminum
stainless steel
No
JBBS-49-M413
4
mini
aluminum
stainless steel
No
JBBS-49-M814
8
mini
aluminum
nickel-plated brass
No
JBBS-49-M614
6
mini
aluminum
nickel-plated brass
No
JBBS-49-M414
4
mini
aluminum
nickel-plated brass
No
JBBS-49-M823
8
mini
fiberglass
stainless steel
No
JBBS-49-M623
6
mini
fiberglass
stainless steel
No
JBBS-49-M423
4
mini
fiberglass
stainless steel
No
JBBS-49-M824
8
mini
fiberglass
nickel-plated brass
No
JBBS-49-M624
6
mini
fiberglass
nickel-plated brass
No
JBBS-49-M424
4
mini
fiberglass
nickel-plated brass
No
JBBS-49SC-M813
8
mini
aluminum
stainless steel
Yes
JBBS-49SC-M613
6
mini
aluminum
stainless steel
Yes
JBBS-49SC-M413
4
mini
aluminum
stainless steel
Yes
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
2
29
eurofast® Passive Multiport Junctions (Bricks)
SC models only
Description
Rugged, fully encapsulated die-cast aluminum brick with eurofast® connectors.
JBBS-49-E813
JBBS-49-E613
JBBS-49-E413*
Dimensions /
Part Number
* JBBS-49SC-E413 overall dimensions 7.3mm X 2.52mm
Short Circuit Protection (only available with SC models)
Applications
Electrical
Short Circuit Protection: 55mA(Isc)
Voltage Open Circuit: 35VDC
Current Consumption: 5mA
•
•
•
Diagnostic
•
LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
Cl 1, Div 2; Groups A-D
see InterlinkBT® drawing N1-2.400
T6, Ta = 70 degrees C
For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-49-E413 to JBBS-49-E414
For fiberglass housing change part number to -Ex2x. Example: JBBS-49-E613 to JBBS-49-E623
30
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Short Circuit Protected
Connector Size
Connector Material
Part Number
Number of Ports
Housing Material
Quick Selection Guide
JBBS-49-E813
8
euro
aluminum
stainless steel
No
JBBS-49-E613
6
euro
aluminum
stainless steel
No
JBBS-49-E413
4
euro
aluminum
stainless steel
No
JBBS-49-E814
8
euro
aluminum
nickel-plated brass
No
JBBS-49-E614
6
euro
aluminum
nickel-plated brass
No
JBBS-49-E414
4
euro
aluminum
nickel-plated brass
No
JBBS-49-E823
8
euro
fiberglass
stainless steel
No
JBBS-49-E623
6
euro
fiberglass
stainless steel
No
JBBS-49-E423
4
euro
fiberglass
stainless steel
No
JBBS-49-E824
8
euro
fiberglass
nickel-plated brass
No
JBBS-49-E624
6
euro
fiberglass
nickel-plated brass
No
JBBS-49-E424
4
euro
fiberglass
nickel-plated brass
No
JBBS-49SC-E813
8
euro
aluminum
stainless steel
No
JBBS-49SC-E613
6
euro
aluminum
stainless steel
No
JBBS-49SC-E413
4
euro
aluminum
stainless steel
No
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
2
31
Device Gland Receptacles - 3 wire
Selection Guide
eurofast®
minifast®
1/2 - NPT
FSV 49-*M / 14.5
RSFV 49-*M / 14.5
3/4 - NPT
FSV 49-*M / 14.75
RSFV 49-*M / 14.75
M20
FSV 49-*M / M20
RSFV 49-*M / M20
* For female receptacles change part number to (FKV, RKFV...).
FSV 49-*M / 14.5
RSFV 49-*M / 14.5
FSV 49-*M / 14.75
RSFV 49-*M / 14.75
FSV 49-*M / M20
RSFV 49-*M / M20
minifast®
eurofast®
1.
2.
3.
4.
32
Blue (-Voltage)
Brown (+ Voltage)
N/C
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Device Gland Receptacles - 2 wire
Selection Guide
eurofast®
minifast®
1/2 - NPT
FSV 49T
-*M / 14.5
49T-*M
RSFV 49T
-*M / 14.5
49T-*M
3/4 - NPT
FSV 49T
-*M / 14.75
49T-*M
RSFV 49T
-*M / 14.75
49T-*M
M20
FSV 49T
-*M / M20
49T-*M
RSFV 49T
-*M / M20
49T-*M
* Indicates length in meters.
For female receptacles change part number to (FKV, RKFV...).
2
RSFV 49T
-*M / 14.5
49T-*M
FSV 49T
-*M / 14.5
49T-*M
FSV 49T
-*M / 14.75
49T-*M
RSFV 49T
-*M / 14.75
49T-*M
FSV 49T
-*M / M20
49T-*M
RSFV 49T
-*M / M20
49T-*M
minifast®
eurofast®
1.
2.
3.
4.
Blue (-Voltage)
Brown (+Voltage)
N/C
N/C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
33
Terminating Resistors
Terminate at the beginning and end
of each segment.
minifast® Terminating Resistor
• internal resistor and capacitor
• male connector
1µF
100Ω
RSV 49-TR
eurofast® Terminating Resistor
• internal resistor and capacitor
• male connector
1µF
100Ω
RSEV 49-TR
For nickel-plated brass change: RSEV 49-TR to RSE 49-TR
RSV 49-TR to RSM 49-TR
34
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
minifast®
eurofast®
2-port
BCA 49-M223
BCA 49-E223
1-port
Conduit Adapter
BCA 49-M123
BCA 49-E123
Schematic
trunk
drop
drop
trunk
drop
Change part number from BCA 49-M223 to BCA 49/P- M223
to fit on PVC coated conduit adapter.
2
Description
The conduit adapter attaches to a standard conduit
body for transition to minifast® or eurofast® connectors.
• Gasket and mounting hardware included (8-32 x 1/2”)
Pinout
Dimensions
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
CROUSE - HINDS Hub Size = 3/4
Shape
Style
Part Number
C
Form 8
Mark 9
C28
C29
LB
Form 8
Mark 9
LB28
LB29
LL
Form 8
Mark 9
LL28
LL29
LR
Form 8
Mark 9
LR28
LR29
Conduit Bodies
Conduit connectors for use with armorfast® cable
O-Z Gedney JMC-50-71 1/2NPT
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
35
FOUNDA
ees
TION™ fieldbus T
OUNDATION
Tees
Part Number
Dimensions
Description
RSV 2RKV 49
minifast® tee
• data, ground, shield
• stainless steel coupling nuts
RSV FKV RKV 49
minifast® to eurofast® drop
• data, ground, shield
• stainless steel coupling nuts
For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...)
For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...)
Part Number
Dimensions
Description
RSCV 2RKCV 49
eurofast ® tee
• stainless steel coupling nuts
36
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable T
ee
Wireable
Tee
2
Description
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience. This allows an extremely rapid changeover to a connectorized network, often in less
than 15 minutes. The Field Wireable IP67 Tee SPTTM13-A49 features standardized minifast®
connectors for the drop connection and field wireable terminals on the trunk connections. This
provides the best of both worlds, reliable connections on the short lengths and ease of
installation planning on the long trunk runs.
SPTTM13-A49
SPTT1-A49
Dimensions
W ir
eT
able
ire
Table
Specifications
Pin
Designation
Color
1
V-
Blue
2
V+
Brown
3
Shield
Bare
4
Ground
Green/Yellow
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
37
Gender Changers and Elbow Connectors
Part Number
Dimensions
Description
RSV RSV 49
minifast® Male Gender Changer
• female cordset to male receptacle
RKV RKV 49
minifast® Female Gender Changer
• male cordset to female receptacle
WSV RKV 49
minifast® Elbow
• right angle male to female connector
RSM 49-FK 4.5*
minifast® to eurofast® Adapter
• minifast ® male to eurofast® female
connector
• nickel-plated brass housing
For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...)
* = Consult factory for availability.
38
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Surge Suppressor
Description
This surge suppressor protects the data communication lines (V+ and V-) rather than just
the shield. The unique multi-stage design provides superior surge protection. The surge
suppressor absorbs the front end of the transient, responding in less than a nanosecond,
then diverts the surge energy to ground. Once the surge has been dissipated the
suppressor automatically resets and waits for the next surge.
2
The minifast ® connectors provide IEC IP67 protection in the rugged polyurethane overmolded
body. The surge suppressor is available with stainless steel coupling nuts and a ground stud.
RSV RKV 49 SS
Dimensions
Specifications
Electrical
• Maximum Operating Voltage: 27 Volts
• Maximum Operating Current: 200mA
• Clamping Action Turn-On: 28.5 Volts
• Maximum Clamping at 2 kA: (8 X 20 µSec): 44 Volts
• Maximum Surge Voltage: 20 kV
• Maximum Surge Current: 2.5kA
• Current Leakage/Line At Operating Voltage: 5µA
• Capacitance/Line At Operating Voltage: 500pF
• Response Time: Less than 1 nanosecond
Mechanical
• Ground Stud: 10-32 Stainless Steel
• Operating Temperature: -40°C to +85°C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
39
Power Supply Conditioner
Description
The Power Supply Conditioner meets the needs of redundant power supplies for
FOUNDATION™ fieldbus. This product has primary and secondary power inputs to supply
two Fieldbus H1 segments. Standard 24VDC power feeds into supplies A and B. It also
takes care of filtering the fieldbus signal from the power source. LED’s indicate which
Power Supply is primary and secondary. Diagnostics provide the status of each power
supply, indicating either READY or ACTIVE. The status is also provided through relay
outputs for further monitoring. Internal switches turn on/off terminators per segment.
BRPC-49-M213
4-Pin Euro = Monitor
5-Pin Mini = Supply A & B
Dimensions
4-Pin Mini = Segment 1 & 2
Electrical
• Supply Voltage (Supply A & B): 12 - 32 VDC
• Supply Surge Protection (Supply A & B): >36 VDC
• Supply Redundancy (Supply A & B):
Supply “A” is Primary. If Supply “A” Voltage drops below 11 V, Supply “B”
becomes Active Supply “A” becomes Active once Voltage >11V
Specifications
40
•
•
•
Output Voltage (Segment 1 & 2): Input Voltage - 3 Volts
Output Current (Segment 1 & 2): <1A
Short Circuit Protection (Segment 1 & 2): >1A to Infinite
Diagnostic
• Power LED Indications: Green - Active / Red - No Power
• Segment LED Indications: Green - Active
• Supply Monitor Contacts (Supply A & B):
Solid State, AC/DC <400 V, <70 mA when supply Voltage >11V, Contact Is Closed
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Lokfast™ Guard
Field
Standard
Wireable
minifast®
eurofast®
SHLD, MINI
SHLD, EURO
SHLD, MINI FW
SHLD, EURO FW
SHLD, MINI (10/bag)
2
Description
The JTBS-49SC series short circuit brick is classified as nonincendive equipment. This means
that it is considered nonarcing under normal operating conditions. In a fieldbus system the
trunk does not need to be serviced under normal operating conditions. The trunk connections
(P1 and S0) are to be locked with a Lokfast™ Guard to mechanically prevent separation.
Assembly/
Disassembly
Specifications
Mechanical
• Dimensions: 43mm X D/A X 39mm
• Material: Nylon 6
• Environmental: Sun Resistant, UV Stable
• Operating Temperature: -30ºC to 100ºC
• Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
41
Bulkhead Feed-Thru Receptacles
panel mount
minifast® Bulkhead Receptacle
• straight male/female feed thru
RSFV RKF 49/22
eurofast® Bulkhead Receptacle
• straight male/female feed thru
FKV FSV 49/M12
For nickel-plated brass coupling nuts change part number to: RSFV RKFV 49/22 to RSF RKF 49/22
or
FKV FSV 49/M12 to FKM FS 49/M12
42
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Panel Mount Receptacles - minifast®, eurofast®
Female
Male
minifast®
RKFV 49 - *M
RSFV 49 - *M
eurofast®
FKV 49 - *M
FSV 49 - *M
minifast®
RKFV 490 - *M
RSFV 490 - *M
eurofast®
FKV 490 - *M
FSV 490 - *M
Cable
Leads
Selection Guide
2
* Indicates length in meters.
RKFV 49
RSFV 49
FSV 49
FKV 49
Part numbers on diagrams represent solder cups only.
eurofast®
Female
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
43
Field W
ireable Connectors - minifast®
Wireable
Aluminumx
Stainless Steelx
Female
B 4149-0/9
BV 4149-0/9
Male
BS 4149-0/9
BSV 4149-0/9
Selection Guide
Accepts 6-8 mm (0.236” to 0.315”) cable
B 4149-0/9
BS 4149-0/9
BV 4149-0/9
BSV 4149-0/9
Male
Female
1.
2.
3.
4.
44
x - coupling nut material
housing material - nylon
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable Connectors - eurofast ®
Wireable
Selection Guide
Straight
Right Angle
Female
B8141-0/PG9
B8241-0/PG9
Male
BS8141-0/PG9
BS8241-0/PG9
Accepts 4-8 mm (0.157” to 0.315”) cable
2
B8141-0/PG9
B8241-0/PG9
BS8141-0/PG9
BS8241-0/PG9
Female eurofast®
Male eurofast®
1.
2.
3.
4.
Rating: 3 A, 36 VDC
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
Rating: 3 A, 36 VDC
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
45
Closure Caps
Closure caps are for unused ports on the junction box.
Dimensions
Description
RKMV BC
minifast® closure cap
• mates to male receptacles
• Stainless steel
• IP67 rated
RSMV BC
minifast® closure cap
• mates to female receptacles
• Stainless steel
• IP67 rated
RSFK-BC (10/BAG)
minifas
minifast® Closure Cap
• mates to female receptacles
• nylon
VZ-3 (8/BAG)
eurofast® Closure Cap
• mates to female receptacles
• nylon
46
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
PROFIBUS®-P
A Cables and Accessories
-PA
3
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
47
PROFIBUS®-P
A
-PA
PROFIBUS®-PA (Process Automation) uses synchronous transfer mode technology, as defined in IEC 61158-2,
to communicate between field devices and the RS 485 backbone of PROFIBUS®-DP. A segment coupler, or
gateway is installed to bridge PROFIBUS®-DP with PROFIBUS®-PA. Otherwise, the protocols are identical,
allowing transparent communication between general purpose automation systems and decentralized field
devices.
PROFIBUS®-PA is a master-slave bus. Transmitters used in the process industry are typically slave devices or
passive stations which only communicate at the request of the master.
General Layout T
opologies
Topologies
The topology for PROFIBUS®-DP is a linear bus. Branching can be accomplished with repeaters or, in the case of
PROFIBUS®-PA, this can be accomplished with the segment couplers. The PROFIBUS®-PA topology follows the
physical layer as defined in ISA SP50.02. daisy chain or star topologies are allowed.
48
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Star T
opology Method
Topology
A star topology has a central connection point to all terminations. This layout works well when there are many
devices in a localized area. For instance, the control room may be located about 300 meters away from a cracker
tower. This tower may have five or six temperature transmitters. All of these devices need to be connected to the
fieldbus segment. The best design would be to connect them all to a junction brick and then run a Home Run cable
e 4 for a pictorial example.
from the junction brick back to the control room. See Figur
Figure
The Home Run cable is considered the main trunk line of communication. Each device that is connected to the
junction brick is called a spur. In other industrial networks spurs are called drops off the trunk line.
3
Figure 4 - Star Topology Example
Daisy Chain Configuration
Another layout design is to daisy chain all the devices. Each device would require a tee so that the Home Run
cable would be able to go to each device. From a design standpoint, the Daisy Chain method is easiest to do
when the exact cable tracks are known. Pre-made cordsets can then be purchased and the network is easy to
e 5 for an example drawing. A fieldbus transmitter is connected to each of the tanks in the
assemble. See Figur
Figure
field. The Home Run cable essentially is routed to each device in series.
Transmitters
Figure 5 - Daisy Chain Layout
In many fieldbus installations it makes sense to mix both Star and Daisy Chain topology layouts. Remember that one
of the benefits to fieldbus is reduced wiring of devices, leading to faster start-up times.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
49
Fieldbus Cable Specifications
The specifications for PROFIBUS®-PA physical media are defined by IEC 1158-2 and the ISA-S50.02 Part 2
Physical Layer Standards. There are essentially four types of cable designations for fieldbus. Type A cable is the
most preferred for new installations because it allows for the most versatile lengths. The other types of cable are
able 1
for installations where cable already exists from 4-20 mA systems. See T
Table
1.
Type
Cable Description
Conductor Size
Maximum Length
Type A
Shielded, Twisted Pair
# 18 Awg
1900 m (6232 ft)
Type B
Shielded, Multi Twisted Pair
# 22 Awg
1200 m (3936 ft)
Type C
Unshielded, Multi Twisted Pair
# 26 Awg
400 m (1312 ft)
Type D
Shielded, Untwisted Pair
# 16 Awg
200 m (656 ft)
Table 1 Fieldbus Cable Specifications
InterlinkBT® offers cables with both two conductors and three conductors, with the third conductor available for a
centralized ground of devices if needed. InterlinkBT® cables meet or exceed the specifications of ANSI/ISA-SP50.021992, the fieldbus standard for use in industrial control systems.
The maximum spur length is determined by the number of devices in the segment.
Cable
Trunk
1900 m
50
Number of Devices
Maximum Spur Length
25-32
0 m (0 ft)
19-24
30 m (98 ft)
15-18
60 m (197 ft)
13-14
90 m (295 ft)
2-12
120 m (394 ft)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
PROFIBUS®-P
A - Cable Specifications
-PA
Our cable meets requirements of ISA/SP50
and PROFIBUS®-PA Type A cable. All cables
are rated -40ºC to 105ºC and are sunlight
resistant. Available in 3-wire versions with a
device ground or 2-wire versions.
1
Cable Specifications
Type A Cable
- Designed for harsh environments
- Temperature range of -40 to 105°C (-40 to +221F)
11
- Governed by: ISA SP50.02 specification
- Sunlight resistant per test
- PLTC and ITC rated (CSA FT4)
- Impedence[Z0 at fr (31.25 kHz)] = 100Ω ± 20%
- Maximum attenuation at 1.25 fr (39 kHZ) = 3.0 dB/km
- Maximum capacitive unbalance to shield = 2 nF/km
- Maximum DC resistance (per conductor) = 24 Ω/km
- Maximum propagation delay variance 0. 25 fr to 1.25 fr = 1.7 µs/km
- Conductor cross-sectional area (wire size) = nominal 0.8 mm2 (#18 AWG)
- Minimum shield coverage shall be 90%
Data Pair
Type
483
105°C 300V
483B
105°C 300V
482A
105°C 300V
482BA
105°C 300V
483BK
105°C 300V
Approvals
33
Device Ground
Outer Jacket
Shield
AWG
Color Code
DCR (/1000 ft)
Insulation
AWG Color Code
Material Color
Nominal O.D.
Type
Drain Wire
Bulk Cable
Part No.
Ref.
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Orange
7.9mm (.310 in.)
Foil/Braid
20 AWG
RB50785-*M
1
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Blue
7.9mm (.310 in.)
Foil/Braid
20 AWG
RB50786-*M
1
NEC ITC PLTC/CM
CEC [CMG HLBCD]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
18 AWG
Green/Yellow
Armor/PVC Orange
12.7mm (0.5 in.)
Foil
18 AWG
RB50929-*M
11
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
18 AWG
Green/Yellow
Armor/PVC Blue
12.7mm (0.5 in.)
Foil
18 AWG
RB50952-*M
11
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Black
7.9mm (.310 in.)
Foil/Braid
20 AWG
RB50860-*M
1
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
51
PROFIBUS®-P
A - C ables and C or
dsets
-PA
ordsets
minifast® †
Try Cordset Builder Online!
Pin (Male)
www.interlinkbt.com
RSV
WSV
eurofast®
Pin (Male)
Socket (Female)
RKV
RSCV
WKV
RSV 48x - *M
WSV 48x -*M
RKV 48x -*M
WKV 48x -*M
RSCV 48x -*M
RSV RSV 48x -*M
RSV WSV 48x -*M
RSV RKV 48x -*M
RSV WKV 48x -*M
RSV RSCV 48x -*M
WSV WSV 48x -*M
WSV RKV 48x -*M
WSV WKV 48x -*M
WSV RSCV 48x -*M
RKV RKV 48x -*M
RKV WKV 48x -*M
RKV RSCV 48x -*M
WKV WKV 48x -*M
WKV RSCV 48x -*M
RSV
WSV
Socket (Female)
minifast®†
Pin (Male)
Bare
RKV
×
*
†
RSCV RSCV 48x -*M
RSCV
WSCV
Socket (Female)
eurofast®
Pin (Male)
WKV
RKCV
WKCV
Indicates cable type
Indicates length in meters
Consult factory for availability of armorfast® with eurofast® connectors.
armorfast ® cable only
For nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
Bulk cable, see page 8 for standard lengths
WSV RSCV 482-*M
Example
1 METER
52
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
PROFIBUS®-P
A - C ables and Cor
dsets
-PA
ordsets
eurofast®
Pin (Male)
WSCV
WSCV 48x -*M
minifast® bulkhead
Socket (Female)
RKCV
RKCV 48x -*M
WKCV
WKCV 48x -*M
Pin (Male)
RSFPV
RSFPV 48x -*M
Socket (Female)
RKFPV
eurofast® bulkhead
Pin (Male)
FSFDV
Socket (Female)
FKFDV
RKFPV 48x -*M
FSFDV 48x -*M
FKFDV 48x -*M
RSV WSCV 48x -*M
RSV RKCV 48x -*M
RSV WKCV 48x -*M
RSV RSFPV 48x -*M
RSV RKFPV 48x -*M
RSV FSFDV 48x -*M
RSV FKFDV 48x -*M
WSV WSCV 48x -*M
WSV RKCV 48x -*M
WSV WKCV 48x -*M
WSV RSFPV 48x -*M
WSV RKFPV 48x -*M
WSV FSFDV 48x -*M
WSV FKFDV 48x -*M
RKV WSCV 48x -*M
RKV RKCV 48x -*M
RKV WKCV 48x -*M
RKV RSFPV 48x -*M
RKV RKFPV 48x -*M
RKV FSFDV 48x -*M
RKV FKFDV 48x -*M
WKV WSCV 48x -*M
WKV RKCV 48x -*M
WKV WKCV 48x -*M
WKV RSFPV 48x -*M
WKV RKFPV 48x -*M
WKV FSFDV 48x -*M
WKV FKFDV 48x -*M
RSCV WSCV 48x -*M
RSCV RKCV 48x -*M
RSCV WKCV 48x -*M
RSCV RSFPV 48x -*M
RSCV RKFPV 48x -*M RSCV FSFDV 48x -*M RSCV FKFDV 48x -*M
WSCV WSCV 48x -*M WSCV RKCV 48x -*M
WSCV WKCV 48x -*M
WSCV RSFPV 48x -*M
WSCV RKFPV 48x -*M WSCV FSFDV 48x -*M WSCV FKFDV 48x -*M
RKCV RKCV 48x -*M
RKCV WKCV 48x -*M
RKCV RSFPV 48x -*M
RKCV RKFPV 48x -*M RKCV FSFDV 48x -*M RKCV FKFDV 48x -*M
WKCV WKCV 48x -*M
WKCV RSFPV 48x -*M WKCV RKFPV 48x -*M WKCV FSFDV 48x -*M WKCV FKFDV 48x -*M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
3
53
minifast® C or
dset and Receptacle Connector D imensions and Pinouts
ordset
RSV
-*
RSV-*
RKV
-*
RKV-*
WSV
-*
WSV-*
WKV-*
RSFPV
-*
RSFPV-*
RKFPV
-*
RKFPV-*
Mounting Installation
5.0
1.8
30.5
Female
Male
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
54
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® C or
dset and R eceptacle C onnector D imensions and Pinouts
ordset
RSCV
-*
RSCV-*
RKCV
-*
RKCV-*
WSCV
-*
WSCV-*
WKCV
-*
WKCV-*
3
FSFDV
-*
FSFDV-*
Mounting Installation
FKFDV
-*
FKFDV-*
Female
Male
1. Brown (+ Voltage)
2. N/C
3. Blue (- Voltage)
4. Bare (Shield Drain Wire)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
55
Short Circuit minifast® Junction T
ee
Tee
SC models only
Description
The PROFIBUS®-PA junction tee is available with short circuit protection.
Mechanically rugged, the new overmolded design provides unparalleled corrosive resistance.
JTBS-48SC-M633
4-Pin Male
P1
4-Pin Female
Dimensions
S0-S6
MOUNTING SCREW
1/4” (2)
NOT INCLUDED
Short Circuit Protection (only available with SC models)
Specifications
Electrical
Short Circuit Protection: 55mA(Isc)
Voltage Open Circuit: 35VDC
Current Consumption: 5mA
•
•
•
Diagnostic
•
LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
56
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connector size
Overmold material
Short Circuit Protected
Number of ports
Connector material
Quick Selection Guide
JTBS-48-M433
4
mini
polyurethane
stainless steel
No
JTBS-48-M434
4
mini
polyurethane
nickel-plated brass
No
JTBS-48-M633
6
mini
polyurethane
stainless steel
No
JTBS-48-M634
6
mini
polyurethane
nickel-plated brass
No
JTBS-48SC-M433
4
mini
polyurethane
stainless steel
Yes
JTBS-48SC-M434
4
mini
polyurethane
nickel-plated brass
Yes
JTBS-48SC-M633
6
mini
polyurethane
stainless steel
Yes
JTBS-48SC-M634
6
mini
polyurethane
nickel-plated brass
Yes
JTBS-48-E433
4
euro
polyurethane
stainless steel
No
JTBS-48-E434
4
euro
polyurethane
nickel-plated brass
No
JTBS-48-E633
6
euro
polyurethane
stainless steel
No
JTBS-48-E634
6
euro
polyurethane
nickel-plated brass
No
JTBS-48SC-E433
4
euro
polyurethane
stainless steel
Yes
JTBS-48SC-E434
4
euro
polyurethane
nickel-plated brass
Yes
JTBS-48SC-E633
6
euro
polyurethane
stainless steel
Yes
JTBS-48SC-E634
6
euro
polyurethane
nickel-plated brass
Yes
Part Number
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
3
57
minifast® Passive Multiport Junctions (Bricks)
SC models only
Description
• Keyed for PROFIBUS®-PA Systems
• Rugged, fully encapsulated die-cast aluminum enclosures
• Bus-In/Bus-Out eliminate need for splitter tee
• Provide common ground for all devices
• Stainless steel receptacles
JBBS-48-M813
JBBS-48-M613
JBBS-48-M413
Dimensions /
Part Number
Short Circuit Protection (only available with SC models)
Applications
Electrical
•
Short Circuit Protection: 55mA(Isc)
•
Voltage Open Circuit: 35VDC
•
Current Consumption: 5mA
Diagnostic
•
LED Indication:
Green LED - Bus Power
Red LED - Short Circuit Indication
For nickel-plated brass receptacles change part number to -Mxx4. Example: JBBS-48-M413 to JBBS-48-M414
For fiberglass housing change part number to -Mx2x. Example: JBBS-48-M613 to JBBS-48-M623
58
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connector size
Housing material
Short Circuit Protected
Number of ports
Connector material
Quick Selection Guide
JBBS-48-M813
8
mini
aluminum
stainless steel
No
JBBS-48-M613
6
mini
aluminum
stainless steel
No
JBBS-48-M413
4
mini
aluminum
stainless steel
No
JBBS-48-M814
8
mini
aluminum
nickel-plated brass
No
JBBS-48-M614
6
mini
aluminum
nickel-plated brass
No
JBBS-48-M414
4
mini
aluminum
nickel-plated brass
No
JBBS-48-M823
8
mini
fiberglass
stainless steel
No
JBBS-48-M623
6
mini
fiberglass
stainless steel
No
JBBS-48-M423
4
mini
fiberglass
stainless steel
No
JBBS-48-M824
8
mini
fiberglass
nickel-plated brass
No
JBBS-48-M624
6
mini
fiberglass
nickel-plated brass
No
JBBS-48-M424
4
mini
fiberglass
nickel-plated brass
No
JBBS-48SC-M813
8
mini
aluminum
stainless steel
Yes
JBBS-48SC-M613
6
mini
aluminum
stainless steel
Yes
JBBS-48SC-M413
4
mini
aluminum
stainless steel
Yes
Part Number
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
3
59
eurofast® Passive Multiport Junctions (Bricks)
Description
•
•
•
•
•
Keyed for PROFIBUS®-PA Systems
Rugged, fully encapsulated die-cast aluminum enclosures
Bus-In/Bus-Out eliminate need for splitter tee
Provide common ground for all devices
Stainless steel receptacles
JBBS-48-E813
JBBS-48-E613
JBBS-48-E413
Dimensions /
Part Number
Applications
8, 6, and 4-Port Junction Bricks
• bus-in / bus-out straight throughports
• spurs with eurofast® connectors
For nickel-plated brass receptacles change part number to -Exx4. Example: JBBS-48-E413 to JBBS-48-E414
For fiberglass housing change part number to -Ex2x. Example: JBBS-48-E613 to JBBS-48-E623
60
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Connector size
Housing material
Short Circuit Protected
Part Number
Number of ports
Connector material
Quick Selection Guide
JBBS-48-E813
8
euro
aluminum
stainless steel
No
JBBS-48-E613
6
euro
aluminum
stainless steel
No
JBBS-48-E413
4
euro
aluminum
stainless steel
No
JBBS-48-E814
8
euro
aluminum
nickel-plated brass
No
JBBS-48-E614
6
euro
aluminum
nickel-plated brass
No
JBBS-48-E414
4
euro
aluminum
nickel-plated brass
No
JBBS-48-E823
8
euro
fiberglass
stainless steel
No
JBBS-48-E623
6
euro
fiberglass
stainless steel
No
JBBS-48-E423
4
euro
fiberglass
stainless steel
No
JBBS-48-E824
8
euro
fiberglass
nickel-plated brass
No
JBBS-48-E624
6
euro
fiberglass
nickel-plated brass
No
JBBS-48-E424
4
euro
fiberglass
nickel-plated brass
No
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
3
61
Device Gland Receptacles - 2 wire
Selection Guide
eurofast®
minifast®
1/2 - NPT
FSV 48T
-*M / 14.5
48T-*M
RSFV 48T
-*M / 14.5
48T-*M
3/4 - NPT
FSV 48T
-*M / 14.75
48T-*M
RSFV 48T
-*M / 14.75
48T-*M
M20
FSV 48T
-*M / M20
48T-*M
RSFV 48T
-*M / M20
48T-*M
* Indicates length in meters.
For female receptacles change part number to (FKV, RKFV...).
RSFV 48T
-*M / 14.5
48T-*M
FSV 48T
-*M / 14.5
48T-*M
FSV 48T
-*M / 14.75
48T-*M
RSFV 48T
-*M / 14.75
48T-*M
FSV 48T
-*M / M20
48T-*M
RSFV 48T
-*M / M20
48T-*M
eurofast®
minifast®
1.
2.
3.
4.
62
Brown (+ Voltage)
N/C
Blue (- Voltage)
N/C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Terminating Resistors
terminate at the beginning
and end of each segment
3
minifast® Terminating Resistor
• internal resistor and capacitor
• male connector
1µF 100Ω
RSV 48-TR
eurofast® Terminating Resistor
• internal resistor and capacitor
• male connector
1µF
100Ω
RSEV 48-TR
For nickel-plated brass change: RSEV 48-TR to RSE 48-TR
RSV 48-TR to RSM 48-TR
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
63
Terminating Resistors - Ex
terminate at the beginning
and end of each segment
minifast® Terminating Resistor
• internal resistor and capacitor
• male connector
1µF 100Ω
RSV 48-TR-Ex
eurofast ® Terminating Resistor
• internal resistor and capacitor
• male connector
1µF
100Ω
RSEV 48-TR-Ex
For nickel-plated brass change: RSEV 48-TR-Ex to RSE 48-TR-Ex
RSV 48-TR-Ex to RSM 48-TR-Ex
Ex Approval
BVS 99.E.2044X
Entity Parameters:
U : ≥ 16.2V
I : ≥ 500mA
P : ≥ 1.8W
T:
-40ºC...+70ºC (EEx ia IIC T4)
-40ºC...+70ºC (EEx ia IIC T6)
0
0
0
a
64
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Conduit Adapter
minifast®
Schematic
2-port
BCA 48-E223
BCA 48-M123
BCA 48-E123
drop
BCA 48-M223
1-port
trunk
drop
trunk
drop
Description
eurofast®
The conduit adapter attaches to a standard conduit
body for transition to minifast® or eurofast® connectors.
• Gasket and mounting hardware included (8-32 x 1/2”)
Pinout
3
Dimensions
1.
2.
3.
4.
Brown (+ Voltage)
N/C
Blue (- Voltage)
Bare (Shield Drain Wire)
CROUSE - HINDS Hub Size = 3/4
Shape
Style
Part Number
C
Form 8
Mark 9
C28
C29
LB
Form 8
Mark 9
LB28
LB29
LL
Form 8
Mark 9
LL28
LL29
LR
Form 8
Mark 9
LR28
LR29
Conduit Bodies
Conduit connectors for use with armorfast® cable
O-Z Gedney JMC-50-71 1/2NPT
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
65
PROFIBUS®-P
A T
ees
-PA
Tees
Part Number
Dimensions
Description
RSV 2RKV 48
minifast® tee
• data, ground, shield
• stainless steel coupling nuts
RSV FKV RKV 48
minifast ® to eurofast® drop
• data, ground, shield
• stainless steel coupling nuts
For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...)
For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...)
Part Number
Dimensions
Description
RSCV 2RKCV 48
eurofast® tee
• stainless steel coupling nuts
66
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable T
ee
Wireable
Tee
Description
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.
This allows an extremely rapid changeover to a connectorized network, often in less than 15
®
minutes. The Field Wireable IP67 SPTTM13-A48 tee features standardized minifast connectors
for the drop connection and field wireable terminals on the trunk connections. This provides the
best of both worlds, reliable connections on the short lengths and ease of installation planning on
the long trunk runs.
SPTT1-A48
SPTTM13-A48
3
Dimensions
W ir
eT
able
ire
Table
Specifications
Pin
Designation
Color
1
PA+
Brown
2
N/C
--
3
PA-
Blue
4
Shield
Drain
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
67
Gender Changers and Elbow Connectors
Part Number
Dimensions
Description
RSV RSV 48
minifast® Male Gender Changer
• female cordset to male receptacle
RKV RKV 48
minifast® Female Gender Changer
• male cordset to female receptacle
WSV RKV 48
minifast® Elbow
• right angle male to female connector
RSM 48-FK 4.5*
minifast® to eurofast® Adapter
• minifast® male to eurofast® female
connector
• nickel-plated brass housing
For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...)
Consult factory for availability of stainless steel.
68
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Surge Suppressor
Description
This surge suppressor protects the data communication lines (V+ and V-) rather than just the
shield. The unique multi-stage design provides superior surge protection. The surge suppressor
absorbs the front end of the transient, responding in less than a nanosecond, then diverts the
surge energy to ground. Once the surge has been dissipated the suppressor automatically
resets and waits for the next surge.
The minifast® connectors provide IP67 protection in the rugged polyurethane overmolded body.
The surge suppressor is available with stainless steel coupling nuts and ground stud.
RSV RKV 48 SS
3
Dimensions
Specifications
Electrical
• Maximum Operating Voltage: 27 Volts
• Maximum Operating Current: 200mA
• Clamping Action Turn-On: 28.5 Volts
• Maximum Clamping at 2 kA: (8 X 20 µSec) : 44 Volts
• Maximum Surge Voltage: 20 kV
• Maximum Surge Current: 2.5kA
• Current Leakage/Line At Operating Voltage: 5µA
• Capacitance/Line At Operating Voltage: 500pF
• Response Time: Less than 1 nanosecond
Mechanical
• Ground Stud: 10-32 Stainless Steel
• Operating Voltage: 24 Volts
• Operating Temperature: -40°C to +85°C
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
69
Lokfast™ Guard
Field
Standard
Wireable
minifast®
eurofast®
SHLD, MINI
SHLD, EURO
SHLD, MINI FW
SHLD, EURO FW
SHLD, MINI (10/bag)
Description
The JTBS-48SC series short circuit brick is classified as nonincendive equipment.
This means that it is considered nonarcing under normal operating conditions. In a
fieldbus system the trunk does not need to be serviced under normal operating
conditions. The trunk connections (P1 and S0) are to be locked with a Lokfast™
Guard to mechanically prevent separation.
Assembly/
Disassembly
Specifications
70
Mechanical
• Dimensions: 43mm X D/A X 39mm
• Material: Nylon 6
• Environmental: Sun Resistant, UV Stable
• Operating Temperature: -30ºC to 100ºC
• Flammability: UL94 (5=V-0; 4=V-1; 3=V-2; 1=HB)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Bulkhead Feed-Thru Receptacles
panel mount
3
minifast® Bulkhead Receptacle
• straight male/female feed thru
RSFV RKF 48/22
eurofast® Bulkhead Receptacle
• straight male/female feed thru
FKV FSV 48/M12
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
71
Panel Mount Receptacles - minifast®, eurofast®
Female
Male
minifast®
RKFV 48 - *M
RSFV 48 - *M
eurofast®
FKV 48 - *M
FSV 48 - *M
minifast®
RKFV 483 - *M
RSFV 483 - *M
eurofast®
FKV 483 - *M
FSV 483 - *M
cable
leads
Selection Guide
RKFV 48 - *M
RSFV 48 - *M
FKV 48 - *M
FSV 48 - *M
eurofast®
Female
1.
2.
3.
4.
72
Brown (+ Voltage)
N/C
Blue (- Voltage)
Bare (Shield Drain Wire)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable Connectors - minifast®
Wireable
Selection Guide
Aluminumx
Stainless Steelx
Female
B 4148-0/9
BV 4148-0/9
BS 4148-0/9
BSV 4148-0/9
Male
x - coupling nut
housing material - nylon
Accepts 6-8 mm (0.236” to 0.315”) cable
B 4148-0/9
BS 4148-0/9
3
BSV 4148-0/9
BV 4148-0/9
Male
Female
1.
2.
3.
4.
Brown (+ Voltage)
N/C
Blue (- Voltage)
Bare (Shield Drain Wire)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
73
Field W
ireable Connectors - eurofast®
Wireable
Selection Guide
Straight
Right Angle
Female
B8141-0/PG9
B8241-0/PG9
Male
BS8141-0/PG9
BS8241-0/PG9
Field wireable connectors for bus lines and drops facilitate field replacement.
B8141-0/PG9
B8241-0/PG9
BS8141-0/PG9
BS8241-0/PG9
Male eurofast®
Female eurofast®
1.
2.
3.
4.
Rating: 3 A, 36 VDC
74
Brown (+ Voltage)
N/C
Blue (- Voltage)
Bare (Shield Drain Wire)
Rating: 3 A, 36 VDC
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Closure Caps
Closure caps are for unused ports on the junction box.
Dimensions
Description
RKMV BC
minifast® closure cap
• mates to male receptacles
• Stainless steel
• IP67 rated
RSMV BC
minifast® closure cap
3
• mates to female receptacles
• Stainless steel
• IP67 rated
RSFK-BC (10/BAG)
minifast® Closure Cap
• mates to female receptacles
• nylon
VZ-3 (8/BAG)
eurofast® Closure Cap
• mates to female receptacles
• nylon
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
75
HAR
T ® Cables and Accessories
HART
76
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
HART® Overview
HART® (Highway Addressable Remote Transducer) is a protocol which supports two-way digital communication for
process measurement and control devices. Although it is not an international standard, it is considered an “open”
protocol, broadly accepted in the process industry. HART® devices can store process related information and
communicate digitally. It can also be used with traditional 4-20 mA devices. This is beneficial if there is a large
existing installed base of 4-20 mA transmitters.
HART® is a master-slave protocol. This means
that when the master calls out the slave’s
address, the slave responds. The master takes
control of the time and operational sequence of
the bus. There can be two masters, including a
hand-held communicator. Up to 15 slave
devices can be connected to one multidrop line
(limitations exist for intrinsically safe areas).
HART® uses the Bell 202 standard frequency
shift keying (FSK) for digital communication.
The FSK signal is superimposed on the 4 to 20
mA analog measurement signal. The FSK signal
does not cause interference with the analog measurement since the average value is zero. The frequency of 1200 hz
is used for a logical ‘1’ and 2200 hz is used for a logical ‘0’.
General Layout Topologies
Field wiring of HART® uses twisted pair cable, either screened as a pair in a cable or multiple screens and an overall
screen on cable containing multiple pairs. There are two basic structures for wiring a system. The first is point-topoint wiring. This means that every pair that connects to an instrument is returned to the control, completely isolated
from the other pairs. This can either be accomplished with twisted pair cable or a bundled multiple pair cable. See
Figure 6
6. The second type of structure is multidrop wiring. This can be used when the HART® enabled transmitters
are operating in digital communication only. The transmitters may be wired with a trunk and drop layout (or a Daisy
Chain). See Figure 7
7. Either of these methods greatly reduce wiring and allow for the most flexibility in expansion.
4
Figur
e 6 - Point-to-Point Example
Figure
Figur
e 7 - Multidrop Example
Figure
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
77
HART® Cable Specifications
The maximum HART® cable length is 1500 meters. However, the physical media is limited by a maximum system
attenuation of 3 dB. This is ensured if there is a resistance-capacitance combination having an RC time-constant
value of 65 µF (the circuit resistance R divided by the capacitance C). The system design must consider both
resistance of the device and the cable, likewise the capacitance of the device and the cable. In a typical system
the host load resistance is 250Ω. HART® recommends a maximum capacitance of 5000 pF on slave devices.
Devices with higher capacitance must list the capacitance number (CN). This number equals the actual device
capacitance divided by 5000 pF. For example, a device with a capacitance of 10,000 pF would have CN = 2.
Resistance is measured for both conductors in series. Capacitance is measured from one conductor to all others
and the screen. The values for InterlinkBT® cables are as follows:
Cable T
ype Description
Type
H40
H120
H190
HM40
2 X 22 AWG + 20 Device Ground
4 Pair, 2 X 22 AWG + 18 AWG Device Ground
8 Pair, 2 X 22 AWG + 18 AWG Device Ground
2 X 18 AWG + Device Ground
Capacitance
150 pF/m
190 pF/m
260 pF/m
140 pF/m
Pair Resistance
112Ω/1000 m
112Ω/1000 m
112Ω/1000 m
43Ω/1000 m
The maximum cable distance is dependent on the cable type and the total capacitance of the devices. The graph
below provides guidelines for cable distances based on the standard InterlinkBT® cable and assuming a 250Ω load
resistor. In the example if the system consisted of 9 devices with an average CN of 2 (i.e. 10,000 pF each) and a
host with 5000 pF capacitance, which totals 0.095 µF (95,000 pF), the maximum cable length would be 900
meters using multidrop structure cable HM40.
Maximum Cable Length
250 ohm Load Resistor
Device CTotal (µF)
0.30
H40
H120
H190
HM40
0.20
0.10
0.00
0
500
1000
1500
Length (meters)
HART® simulation software to determine maximum lengths can be found at www.romilly.co.uk. The software
H-SIM can be downloaded free of charge.
78
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
HAR
T ® - Cable Specifications
HART
A
B
C
D
Twisted pair cable, screened as individual pairs
as specified in HART® Field Communication
Protocol Technical Overview.
4
Data Pair
Approvals
Type
H40
105°C 300V
H40A
105°C 300V
H120
105°C 300V
H190
105°C 300V
HM40
105°C 300V
Device Ground
Outer Jacket
Shield
AWG
Color Code
DCR (/1000 ft)
Insulation
AWG Color Code
Material Color
Nominal O.D.
Type
Drain Wire
Network
Standard
Ref.
NEC PLTC
CEC [CMG]
2/22 AWG
Blue/Brn
16.5 Ohms
PE
20 AWG
Green/Yellow
PVC Grey
7.2mm (.285 in.)
Foil
22 AWG
RB50824-*M
A
NEC ITC PLTC
CEC [CMG]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
18 AWG
Green/Yellow
Armor/PVC Grey
7.9mm (.310 in.)
Foil
18 AWG
RB50939-*M
B
NEC ITC PLTC/CM
CEC [CMG HLBCD]
4 Pairs
2/22 AWG
16.5 Ohms
PE
18 AWG
Green/Yellow
PVC Grey
12.7mm (0.5 in.)
Foil
18 AWG
RB50825-*M
D
NEC ITC PLTC/CM
CEC [CMG HLBCD]
8 Pairs
2/22 AWG
16.5 Ohms
PE
18 AWG
Green/Yellow
PVC Grey
12.7mm (0.5 in.)
Foil
18 AWG
RB50826-*M
C
NEC PLTC
CEC [CMG]]
2/18 AWG
Blue/Brn
6.5 Ohms
PE
None
PVC Grey
7.9mm (.310 in.)
Foil
20 AWG
RB50938-*M
A
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
79
HAR
T ® - Cables and Cor
dsets
HART
Cordsets
minifast® †
Pin (Male)
RSV
RSV Hx 4x - *M
WSV
eurofast®
Pin (Male)
Socket (Female)
RKV
RSCV
WKV
WKV Hx 4x - *M
RSCV Hx 4x - *M
WSV Hx 4x - *M
RKV Hx 4x - *M
RSV WSV Hx 4x - *M
RSV RKV Hx 4x - *M
RSV WKV Hx 4x - *M
RSV RSCV Hx 4x - *M
WSV WSV Hx 4x - *M
WSV RKV Hx 4x - *M
WSV WKV Hx 4x - *M
WSV RSCV Hx 4x - *M
RKV RKV Hx 4x - *M
RKV WKV Hx 4x - *M
RKV RSCV Hx 4x - *M
WKV WKV Hx 4x - *M
WKV RSCV Hx 4x - *M
Pin (Male)
RSV RSV Hx 4x - *M
RSV
WSV
Socket (Female)
minifast® †
Bar
e
Bare
RKV
×
*
†
Pin (Male)
RSCV RSCV Hx 4x - *M
RSCV
WSCV
Socket (Female)
eurofast®
WKV
RKCV
WKCV
Indicates cable type
Indicates length in meters
Consult factory for availability of armorfast® with eurofast® connectors.
Armorfast® cable only
For nickel-plated brass coupling nut: RSV...to RSM...
RSCV...to RSC...
Bulk cable, see page 8 for standard lengths.
Example
80
WSV RSCV H40-1M
1 METER
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
HAR
T ® - Cables and Cor
dsets
HART
Cordsets
eurofast®
Pin (Male)
WSCV
minifast® bulkhead
Socket (Female)
RKCV
WKCV
Pin (Male)
RSFPV
Socket (Female)
RKFPV
eurofast® bulkhead
Pin (Male)
FSFDV
Socket (Female)
FKFDV
WSCV Hx 4x - *M
RKCV Hx 4x - *M
WKCV Hx 4x - *M
RSFPV Hx 4x - *M
RKFPV Hx 4x - *M
FSFDV Hx 4x - *M
FKFDV Hx 4x - *M
RSV WSCV Hx 4x - *M
RSV RKCV Hx 4x - *M
RSV WKCV Hx 4x - *M
RSV RSFPV Hx 4x - *M
RSV RKFPV Hx 4x - *M
RSV FSFDV Hx 4x - *M
RSV FKFDV Hx 4x - *M
WSV WSCV Hx 4x - *M
WSV RKCV Hx 4x - *M
WSV WKCV Hx 4x - *M
WSV RSFPV Hx 4x - *M
WSV RKFPV Hx 4x - *M
WSV FSFDV Hx 4x - *M
WSV FKFDV Hx 4x - *M
RKV WSCV Hx 4x - *M
RKV RKCV Hx 4x - *M
RKV WKCV Hx 4x - *M
RKV RSFPV Hx 4x - *M
RKV RKFPV Hx 4x - *M
RKV FSFDV Hx 4x - *M
RKV FKFDV Hx 4x - *M
WKV WSCV Hx 4x - *M
WKV RKCV Hx 4x - *M
WKV WKCV Hx 4x - *M
WKV RSFPV Hx 4x - *M
WKV RKFPV Hx 4x - *M
WKV FSFDV Hx 4x - *M
WKV FKFDV Hx 4x - *M
RSCV WSCV Hx 4x - *M
RSCV RKCV Hx 4x - *M
RSCV WKCV Hx 4x - *M
RSCV RSFPV Hx 4x - *M
RSCV RKFPV Hx 4x - *M RSCV FSFDV Hx 4x - *M
RSCV FKFDV Hx 4x - *M
4
WSCV WSCV Hx 4x - *M WSCV RKCV Hx 4x - *M WSCV WKCV Hx 4x - *M WSCV RSFPV Hx 4x - *M WSCV RKFPV Hx 4x - *M WSCV FSFDV Hx 4x - *M WSCV FKFDV Hx 4x - *M
RKCV RKCV Hx 4x - *M
RKCV WKCV Hx 4x - *M RKCV RSFPV Hx 4x - *M
RKCV RKFPV Hx 4x - *M RKCV FSFDV Hx 4x - *M
RKCV FKFDV Hx 4x - *M
WKCV WKCV Hx 4x - *M WKCV RSFPV Hx 4x - *M WKCV RKFPV Hx 4x - *M WKCV FSFDV Hx 4x - *M WKCV FKFDV Hx 4x - *M
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
81
minifast® Cor
dset and Receptacle Connector Dimensions and Pinouts
Cordset
RSV
-*
RSV-*
RKV
-*
RKV-*
WSV
-*
WSV-*
WKV-*
RSFPV
-*
RSFPV-*
RKFPV
-*
RKFPV-*
Male
Female
1.
2.
3.
4.
82
Mounting Installation
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Cor
dset and Receptacle Connector Dimensions and Pinouts
Cordset
RSCV
-*
RSCV-*
RKCV
-*
RKCV-*
WSCV
-*
WSCV-*
WKCV
-*
WKCV-*
FSFDV
-*
FSFDV-*
FKFDV
-*
FKFDV-*
Mounting Installation
4
Male
Female
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
83
HAR
T ® - Cables and Cor
dsets
HART
Cordsets
multifast®
Pin (Male)
CSM
CSM H1xx -*M
CSWM
Socket (Female)
CKM
CKWM
CSWM H1xx -*M
CKM H1xx -*M
CKWM H1xx -*M
CSM CSWM H1xx -*M
CSM CKM H1xx -*M
CSM CKWM H1xx -*M
CSWM CSWM H1xx -*M
CSWM CKM H1xx -*M
CSWM CKWM H1xx -*M
CKM CKM H1xx -*M
CKM CKWM H1xx -*M
Pin (Male)
CSM CSM H1xx -*M
CSM
CSWM
Socket (Female)
multifast®
Bare
CKM
CKWM CKWM H1xx -*M
CKWM
Coupling nuts shown are nickel-plated brass. Consult factory for availability of stainless steel.
×
*
Indicates cable type
Indicates length in meters
CSWM CKM H1 - 1M
Bulk cable, see page 8 for standard lengths.
Example
1 METER
84
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
multifast® Receptacle Connector Dimensions and Pinouts
CSM
...CKM...
CSM...CKM...
CSWM
...CKWM...
CSWM...CKWM...
Functional W
iring Diagram
Wiring
for 12-Pin Cor
dset
Cordset
NAMUR HAR
T®
HART
J1
J2
J3
J4
V+
VDrain
V+
VDrain
V+
VDrain
V+
VDrain
Gr
ound
Ground
Drain
Functional W
iring Diagram
Wiring
for 19-Pin Cor
dset
Cordset
NAMUR HAR
T®
HART
Color
VV+
Drain
VV+
Drain
VV+
Drain
VV+
Drain
Gr
ound
Ground
Drain
J1
J2
J3
J4
J5
J6
J7
J8
V+
VDrain
V+
VDrain
V+
VDrain
V+
VDrain
V+
VDrain
V+
VDrain
V+
VDrain
V+
VDrain
Gr
ound
Ground
Drain
Color
VV+
Drain
VV+
Drain
VV+
Drain
VV+
Drain
VV+
Drain
VV+
Drain
VV+
Drain
VV+
Drain
Gr
ound
Ground
Drain
4
Male
Female
Male
Female
12-pin
12-pin
19-pin
19-pin
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
85
HAR
T ® Junction T
ee
HART
Tee
Description
The HART® junction tee provides a rugged connection to all of your fieldbus devices.
Mechanically rugged, the new overmolded design provides unparalled corrosive
resistance. It is also available with either multifast® connectors for point-to-point
wiring, or minifast® connectors for multidrop installations.
JTBS-40H-CS12
P1 12-Pin Male
MOUNTING SCREW
1/4” (2)
NOT INCLUDED
J0-J4
JTBS-70H-CS19
P1 19-Pin Male
J0-J7
JTBS-60HM-RS4
P1 4-Pin Male
J0-J6
Dimensions
* change RS to RSV for stainless steel connectors
change CS to CSV for stainless steel connectors
(consult factory for availability)
Schematic/
Connector
W iring 4-port
W iring 7-port
W iring Multidr
op
Multidrop
HAR
TT
ransmitter
HART
Transmitter
NAMUR Sensor
86
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
mini
polyurethane
stainless steel
No
JTBS-40H-CS12
4
12-pin multi
mini
polyurethane
nickel-plated brass
No
JTBS-70H-CSV19*
7
19-pin multi
mini
polyurethane
stainless steel
No
JTBS-70H-CS19
7
19-pin multi
mini
polyurethane
nickel-plated brass
No
JTBS-40HM-RSV4
4
4-pin mini
mini
polyurethane
stainless steel
No
JTBS-40HM-RS4
4
4-pin mini
mini
polyurethane
nickel-plated brass
No
JTBS-60HM-RSV4
6
4-pin mini
mini
polyurethane
stainless steel
No
JTBS-60HM-RS4
6
4-pin mini
mini
polyurethane
nickel-plated brass
No
Connector Material
12-pin multi
Overmold Material
4
(J0-JX)
Home Run Connector
(P1)
JTBS-40H-CSV12*
Connector Size
Part Number
Number of Ports
Short Circuit Protected
Quick Selection Guide
* Consult factory for availability
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
4
87
eurofast® Multibox Aluminum Junctions (Bricks)
Brick for HART®; point-to-point with Home Run connector.
Description
• Aluminum enclosure
• Nickel-plated brass connectors
Consult factory for availability of stainless steel.
VBM-40H-CS12
VBM-80H-CS19
Dimensions
Schematic/
Connector
W iring 4-port
W iring 8-port
HAR
TT
ransmitter
HART
Transmitter
NAMUR Sensor
88
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
eurofast® Multibox Nylon Junctions (Bricks)
Description
Brick for HART®; point-to-point with Home Run connector
• Nylon enclosure
• Nickel-plated brass connectors
Consult factory for availability of stainless steel.
4MB12-40H-CS12
8MB12-40H-CS19
Dimensions
Schematic/
Connector
W iring 4-port
W iring 8-port
4
HAR
TT
ransmitter
HART
Transmitter
NAMUR Sensor
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
89
Device Gland Receptacles - 3 wire
Selection Guide
eurofast®
minifast®
1/2 - NPT
FSV H4-*M / 14.5
RSFV H4-*M / 14.5
3/4 - NPT
FSV H4-*M / 14.75
RSFV H4-*M / 14.75
M20
FSV H4-*M / M20
RSFV H4-*M / M20
* Indicates length in meters.
For female receptacles change part number to (FKV, RKFV...).
FSV H4-*M / 14.5
RSFV H4-*M / 14.5
FSV H4-*M / 14.75
RSFV H4-*M / 14.75
FSV H4 -*M / M20
RSFV H4-*M / M20
Female eurofast®
Male minifast®
1.
2.
3.
4.
90
Blue (-Voltage)
Brown (+ Voltage)
N/C
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Conduit Adapter
minifast®
Schematic
2-port
2-port
BCA 4H-E223
BCA 4HM-M123
BCA 4HM-E123
drop
BCA 4H-M223
drop
BCA 4HM-E223
drop
BCA 4HM-M223
1-port
trunk
drop
source
trunk
drop
Description
eurofast®
The conduit adapter attaches to a standard conduit
body for transition to minifast® or eurofast® connectors.
• Gasket and mounting hardware included (8-32 x 1/2”)
Pinout
Dimensions
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
N/C
Green/Yellow (Ground)
CROUSE - HINDS Hub Size = 3/4
Shape
Conduit Bodies
Style
Part Number
C
Form 8
Mark 9
C28
C29
LB
Form 8
Mark 9
LB28
LB29
LL
Form 8
Mark 9
LL28
LL29
LR
Form 8
Mark 9
LR28
LR29
4
Conduit connectors for use with armorfast® cable
O-Z Gedney JMC-50-71 1/2NPT
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
91
HAR
T ® Multidrop T
ees
HART
Tees
Part Number
Dimensions
Description
RSV 2RKV HM4
minifast® tee
• data, ground, shield
• stainless steel coupling nuts
RSV FKV RKV HM4
minifast® to eurofast® drop
• data, ground, shield
• stainless steel coupling nuts
For nickel-plated brass coupling nuts: Change part number (RSV 2RKV ... RSM 2RKM ...)
For nickel-plated brass coupling nuts: Change part number (RSCV 2RKCV ... RSC 2RKC ...)
Part Number
Dimensions
Description
RSCV 2RKCV H4
eurofast® tee
• stainless steel coupling nuts
92
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable multidrop® T
ee
Wireable
Tee
Description
The Field Wireable Tee is a hybrid connection offering system-wide “plug-and-play” convenience.
This allows an extremely rapid changeover to a connectorized network, often in less than 15
minutes. The Field Wireable IP67 Tee SPTTM13-AHM4 features standardized minifast® connectors
for the drop connection and field wireable terminals on the trunk connections. This provides the
best of both worlds, reliable connections on the short lengths and ease of installation planning on
the long trunk runs.
SPTTM13-AHM4
SPTT1-AHM4
Dimensions
4
W ir
eT
able
ire
Table
Specifications
Pin
Designation
Color
1
V-
Blue
2
V+
Brown
3
Shield
Bare
4
Ground
Green/Yellow
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
93
Gender Changers and Elbow Connectors
Part Number
Dimensions
Description
RSV RSV H4
minifast® Male Gender Changer
• female cordset to male receptacle
RKV RKV H4
minifast® Female Gender Changer
• male cordset to female receptacle
WSV RKV H4
minifast® Elbow
• right angle male to female connector
RSM H4-FK 4.5
minifast® to eurofast® Adapter
• minifast® male to eurofast® female
connector
• nickel-plated brass housing
For nickel-plated brass coupling nuts: Change part number (RSV RSV...RSM RSM...)
94
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Bulkhead Feed-Thru Receptacles
panel mount
minifast® Bulkhead Receptacle
• straight male/female feed thru
RSFV RKF H4/22
For jam nuts or spare nuts order: LN-SS 1/2-14[10/BAG]
or
LN-SS12[10/BAG]
44
eurofast® Bulkhead Receptacle
• straight male/female feed thru
FKV FSV H4/M12
For nickel-plated brass coupling nuts change part number: RSFV RKFV H4/22 to RSF RKF H4/22
or
FKV FSV H4/M12 to FKM FS H4/M12
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
95
Cable
Leads
Panel Mount Receptacles - minifast®, eurofast®
Selection Guide
Female
Male
minifast®
RKFV H4 - *M
RSFV H4 - *M
eurofast®
FKV H4 - *M
FSV H4 - *M
minifast®
RKFV H40 - *M
RSFV H40 - *M
eurofast®
FKV H40 - *M
FSV H40 - *M
* Indicates length in meters.
RKFV H4 - *M
RSFV H4 - *M
FKV H4 - *M
FSV H4 - *M
Male eurofast®
Female minifast®
1.
2.
3.
4.
96
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Cable
Leads
Panel Mount Receptacles - multifast®
Selection Guide
Female
Male
12-pin
CKF H12
CSF H12
19-pin
CKF H19
CSF H19
12-pin
CKF H120
CSF H120
19-pin
CKF H190
CSF H190
CKF
.. or CSF
..
CKF..
CSF..
4
See page 85 for functional wiring diagram.
Male
Female
Male
Female
12-pin
12-pin
19-pin
19-pin
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
97
Field W
ireable Connectors - minifast®
Wireable
Selection Guide
Aluminum
Stainless Steel
Female
B 4149-0/9
BV 4149-0/9
Male
BS 4149-0/9
BSV 4149-0/9
Accepts 6-8mm cable (.236” - .315”)
B 4149-0/9
BS 4149-0/9
BSV 4149-0/9
BV 4149-0/9
Male
Female
1.
2.
3.
4.
98
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Field W
ireable Connectors - eurofast®
Wireable
Selection Guide
Straight
Right Angle
Female
B8141-0/PG9
B8241-0/PG9
Male
BS8141-0/PG9
BS8241-0/PG9
Accepts 6-8mm cable (.236” - .315”)
B8141-0/PG9
B8241-0/PG9
BS8141-0/PG9
BS8241-0/PG9
4
Housing Material PBT
Coupling Nut Material - Female - nylon
Male - nickel-plated brass
Female eurofast®
Male eurofast®
1.
2.
3.
4.
Blue (-Voltage)
Brown (+ Voltage)
Bare (Shield Drain Wire)
Green/Yellow (Ground)
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
99
Field W
ireable Connectors - multifast®
Wireable
12-pin*
19-pin**
Female
CK 12-0
CKV 19-0
Male
CS 12-0
CSV 19-0
Selection Guide
* Accepts 4-10mm cable (.157” - .394”)
** Accepts 5-12mm cable (.197” - .472”)
CK..
CS..
Female contact holder, female threads
Male contact holder, female threads
See page 85 for functional wiring diagram.
Female
Male
12-pin
100
19-pin
12-pin
19-pin
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Closure Cap
Closure caps are for unused ports on the junction box.
Dimensions
Description
RKMV BC
minifast® closure cap
• mates to male receptacles
• Stainless steel
• IP67 rated
RSMV BC
minifast® closure cap
• mates to female receptacles
• Stainless steel
• IP67 rated
RSFK-BC (10/BAG)
minifast® Closure Cap
4
• mates to female receptacles
• nylon
VZ-3 (8/BAG)
eurofast® Closure Cap
• mates to female receptacles
• nylon
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
101
Index
Symbols
F
4MB12-40H-CS12 ............................................89
8MB12-40H-CS19 ............................................89
B 4148-0/9 .......................................................73
B 4149-09...................................................98, 44
B8141-0/PG9 .....................................99, 74, 45
B8241-0/PG9 ......................................99, 74, 45
BCA 48-E123 ...................................................65
BCA 48-E223 ...................................................65
BCA 48-M123 ..................................................65
BCA 48-M223 ..................................................65
BCA 49-E123 ...................................................35
BCA 49-E223 ...................................................35
BCA 49-M123 ..................................................35
BCA 49-M223 ..................................................35
BCA 4HM-E123 ................................................91
BCA 4HM-E223 ................................................91
BCA 4HM-M123 ...............................................91
BCA 4HM-M223 ...............................................91
BRPC-49-M213 ................................................40
BS 4148-0/9 .....................................................73
BS 4149-0/9 ..............................................98, 44
BS8141-0/PG9 ...................................99, 74, 45
BS8241-0/PG9 ...................................99, 74, 45
BSV 4148-0/9 ...................................................73
BSV 4149-0/9 ............................................98, 44
BV 4148-0/9 .....................................................73
BV 4149-0/9 ..............................................98, 44
FKV 48 - *M ...........................................................72
FKV 483 - *M .........................................................72
FKV 49 ...................................................................43
FKV 490 - *M .........................................................43
FKV FSV 48/M12 ....................................................71
FKV FSV 49/M12 ....................................................42
FKV FSV H4/M12 ...................................................95
FKV H4 - *M ...........................................................96
FKV H40 - *M .........................................................96
FOUNDATION fieldbus - Cable Specifications ........17
FOUNDATION fieldbus - Cable and Cordsets ...18-19
FSV 48 - *M ............................................................72
FSV 483 - *M ..........................................................72
FSV 48T-*M / 14.5 ..................................................62
FSV 48T-*M / 14.75 ................................................62
FSV 48T-*M / M20 ..................................................62
FSV 49 ...................................................................43
FSV 49-*M / 14.5 ....................................................32
FSV 49-*M / 14.75 ..................................................32
FSV 49-*M / M20 ....................................................32
FSV 490 - *M ..........................................................43
FSV 49T-*M / 14.5 ..................................................33
FSV 49T-*M / 14.75 ................................................33
FSV 49T-*M / M20 ..................................................33
FSV H4 - *M ...........................................................96
FSV H4-*M / 14.5 ...................................................90
FSV H4-*M / 14.75 .................................................90
FSV H4-*M / M20 ...................................................90
FSV H40 - *M .........................................................96
C
H
CK 12-0 ..........................................................100
CKF H12.............................................................97
CKF H120 .........................................................97
CKF H19 ...........................................................97
CKF H190 ..........................................................97
CKV 19-0 ........................................................100
Connector Specifications ....................................7
CS 12-0 ..........................................................100
CSF H12 ...........................................................97
CSF H120 .........................................................97
CSF H19 ...........................................................97
CSF H190 .........................................................97
CSV 19-0 ........................................................100
HART - Cable Specifications ..................................79
HART - Cables and Cordsets ......................80-81, 84
B
J
JBBS-48-E413 .......................................................60
JBBS-48-E613 .......................................................60
JBBS-48-E813 .......................................................60
JBBS-48-M413 ......................................................58
JBBS-48-M613 ......................................................58
JBBS-48-M813 ......................................................58
JBBS-49-E413 .......................................................30
JBBS-49-E613 .......................................................30
JBBS-49-E813 .......................................................30
JBBS-49-M413 ......................................................28
E
eurofast® Part Number Keys ...............................9
120
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
Index
JBBS-49-M613 .................................................28
JBBS-49-M813 .................................................28
JTBS-40H-CS12 ...............................................86
JTBS-48SC-M633 .............................................56
JTBS-49-I633 ....................................................26
JTBS-49SC-M633 .............................................24
JTBS-60HM-RS4 ..............................................86
JTBS-70H-CS19 ...............................................86
JTBS Part Number Key .....................................11
M
Marine Cable .....................................................22
minifast® Part Number Keys ..............................10
P
PROFIBUS-PA - Cable Specifications ................51
PROFIBUS-PA - Cables and Cordsets .........52-53
R
RKFV 48 - *M ....................................................72
RKFV 483 - *M ..................................................72
RKFV 49 ............................................................43
RKFV 490 - *M ..................................................43
RKFV H4 - *M ....................................................96
RKFV H40 - *M ..................................................96
RKGV-* ..............................................................23
RKMV BC ..........................................101, 75, 46
RKV RKV 48 ......................................................68
RKV RKV 49 ......................................................38
RKV RKV H4 .....................................................94
RSCV 2RKCV 48 ...............................................66
RSCV 2RKCV 49 ...............................................36
RSCV 2RKCV H4 ..............................................92
RSEV 48-TR ......................................................63
RSEV 48-TR-Ex .................................................64
RSEV 49-TR ......................................................34
RSFK-BC (10/BAG) ...........................101, 75, 46
RSFV 48 - *M ....................................................72
RSFV 483 - *M ..................................................72
RSFV 48T-*M / 14.5 ..........................................62
RSFV 48T-*M / 14.75 ........................................62
RSFV 48T-*M / M20 ..........................................62
RSFV 49 ............................................................43
RSFV 49-*M / 14.5 ............................................32
RSFV 49-*M / 14.75 ..........................................32
RSFV 49-*M / M20 ............................................32
RSFV 490 - *M ..................................................43
RSFV 49T-*M / 14.5 ..........................................33
RSFV 49T-*M / 14.75 ........................................33
RSFV 49T-*M / M20 ........................................33
RSFV H4 - *M .................................................96
RSFV H4-*M / 14.5 .........................................90
RSFV H4-*M / 14.75 .......................................90
RSFV H4-*M / M20 .........................................90
RSFV H40 - *M ...............................................96
RSFV RKF 48/22 .............................................71
RSFV RKF 49/22 .............................................42
RSFV RKF H4/22 ............................................95
RSGV-* ...........................................................23
RSM 48-FK 4.5 ...............................................68
RSM 49-FK 4.5 ...............................................38
RSM H4-FK 4.5 ................................................94
RSMV BC .........................................101, 75, 46
RSV 2RKV 48 ..................................................66
RSV 2RKV 49 ..................................................36
RSV 2RKV HM4 ..............................................92
RSV 48-TR ......................................................63
RSV 48-TR-Ex .................................................64
RSV 49-TR ......................................................34
RSV FKV RKV 48 ............................................66
RSV FKV RKV 49 ............................................36
RSV FKV RKV HM4 .........................................92
RSV RKV 48 SS ..............................................69
RSV RKV 49 SS ..............................................39
RSV RSV 48 ....................................................68
RSV RSV 49 ....................................................38
RSV RSV H4 ...................................................94
S
SHLD, EURO ............................................70, 41
SHLD, EURO FW ......................................70, 41
SHLD, MINI ...............................................70, 41
SHLD, MINI FW ........................................70, 41
SPTT1-A48 ......................................................67
SPTT1-A49 ......................................................37
SPTT1-AHM4 ..................................................93
SPTTM13-A48 .................................................67
SPTTM13-A49 .................................................37
SPTTM13-AHM4 .............................................93
V
VBM-40H-CS12 ..............................................88
VBM-80H-CS19 ..............................................88
VZ-3 (8/BAG) ...................................101, 75, 46
W
WSV RKV 48 ...................................................68
WSV RKV 49 ...................................................38
WSV RKV H4 ..................................................94
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
6
121
V isit us at www
.interlinkbt.com
www.interlinkbt.com
*
Link to support.interlinkbt.com
Web Site Featur
es:
Features:
What’
s New:
What’s
Pr
oducts:
Products:
Sear
ch:
Search:
Tech Support:
Calendar:
Literatur
e:
Literature:
Contacts:
About Us:
Login:
122
Check the latest articles, literature updates and product releases.
Complete listing of network cables and cordsets, interconnection products, accessories,
I/O stations and modules, I/O systems and more.
Use keywords and phrases to locate specific information.
See page 123.
Check out the events in your area.
Contains a complete listing of catalogs, brochures, tutorials, CAD drawings and electronic
news releases from InterlinkBT®. Download pdf files or register for mail copy.
Sales - Find reps and distributors in your area.
Partners - Lists affiliates and trade associations.
Integrators - Contains business summaries and web site links.
Us - Submit requests and comments directly to InterlinkBT®.
Contains company information and opportunities.
The login page provides access to the secure area for the InterlinkBT® sales channel.
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
V isit us at support.interlinkbt.com
* Click Tech Support from interlinkbt.com or visit support.interlinkbt.com
Technical Support W
eb Site Featur
es:
Web
Features:
App. Notes:
CAD Library:
Config. Files:
Documents:
Softwar
e:
Software:
Application Notes contain documents for approvals and testing, mapping and configuration
and application guidelines.
Contains Product CAD Files - search by network and/or part number.
EDS and GSD file search.
Download catalogs, guides, manuals and wiring diagrams.
Lists software that is available for download.
6
InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
123
Warranty
InterlinkBT, LLC (hereinafter “InterlinkBT”) warrants the Products covered by this WARRANTY AGREEMENT to be free from defects in
material and workmanship under normal and proper usage for 18 months from the date of shipment from InterlinkBT.
THE WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER REPRESENTATIONS MADE – BOTH EXPRESSED AND IMPLIED.
THERE ARE NO WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR PRODUCTS COVERED BY THESE TERMS AND CONDITIONS.
InterlinkBT warrants that the goods sold are as described, but no promise, description, affirmation of fact, sample model or representation,
oral or written shall be part of an order, unless set forth in these terms and conditions, or are in writing and signed by an authorized
representative of InterlinkBT. This warranty does not apply to any Product which has been subject to misuse, negligence, or accident – or
to any Product which has been modified or repaired, improperly installed, altered, or disassembled – except according to InterlinkBT’s
written instructions.
This WARRANTY is subject to the following conditions:
1.
2.
3.
4.
This WARRANTY is limited to the electronic and mechanical performance only, as expressly detailed in the Product specifications and
NOT to cosmetic performance.
This WARRANTY shall not apply to any cables attached to, or integrated with the Product. However, the 18 month warranty shall
apply to cables sold separately by InterlinkBT.
This WARRANTY shall not apply to any products which are stored, or utilized, in harsh environmental or electrical conditions outside
written specifications.
The WARRANTY is applicable only to Products shipped from InterlinkBT subsequent to May 1, 1998.
Purchaser’s Remedies
If an InterlinkBT Distributor desires to make a WARRANTY Claim, the Distributor shall, if requested by InterlinkBT, ship the Product to
InterlinkBT’s facility in Minneapolis, Minnesota, postage or freight prepaid. If the User desires to make a WARRANTY Claim, they shall
notify the authorized InterlinkBT Distributor from whom it was purchased or, if such Distributor is unknown, shall notify InterlinkBT. InterlinkBT
shall, at its option, take either of the following two courses of action for any products which InterlinkBT determines are defective in
materials or workmanship.
1.
2.
Repair or replace the Product and ship the Product to the Original Purchaser or to the authorized InterlinkBT Distributor, postage or
freight prepaid; or
Repay to the Original Purchaser that price paid by the Original Purchaser.
PURCHASER’S REMEDIES SHALL BE LIMITED EXCLUSIVELY TO THE RIGHT OF REPLACEMENT, REPAIR OR REPAYMENT AS PROVIDED AND DOES NOT INCLUDE ANY LABOR COST OR REPLACEMENT AT ORIGINAL PURCHASER’S SITE. INTERLINKBT SHALL
NOT BE LIABLE FOR ANY CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF ANY WARRANTY, EXPRESSED OR
IMPLIED, APPLICABLE TO THE PRODUCT, INCLUDING WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM PROPERTY DAMAGE, PERSONAL INJURY OR BUSINESS INTERRUPTION.
Risk of Loss
Delivery of the equipment to a common carrier shall constitute delivery to the Purchaser and the risk of loss shall transfer at that time to
Purchaser. Should delivery be delayed due to an act or omission on the part of the Purchaser, risk of loss shall transfer to the Purchaser
upon notification by InterlinkBT that the order is complete and ready for shipment.
Consider Safety and Protection Precautions
InterlinkBT takes great care to design and build reliable and dependable products, however, some products can fail eventually. You must
take precautions to design your equipment to prevent property damage and personal injury in the unlikely event of failure. As a matter of
policy, InterlinkBT does NOT recommend the installation of electronic controls as a sole device FOR THE PROTECTION OF PERSONNEL
in connection with power driven presses, brakes, shears and similar equipment and, therefore, the customer should build in redundancy
or dual control using approved safety devices for these applications.
Governing Law
The sale and purchase of Products covered hereby and all terms and conditions hereof shall be governed by the law of the State of
Minnesota.
Product Availability
InterlinkBT makes every effort to stock most of these part numbers in reasonable quantities. InterlinkBT also makes no guarantee of
availability of any product represented. Some part numbers are available on a special order basis only and may require longer lead times.
Please consult with InterlinkBT when you need a committed delivery date.
Special Order Items
Certain part numbers require minimum order quantities. As a general guideline, product not listed in this price list may be subject to 25
piece minimum order quantity. If there is any question on availability or minimum order quantities, please contact InterlinkBT before
ordering.
Field Service
124
Please
contact
InterlinkBT
details.
InterlinkBT
3000
Campus for
Drive
Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880
®
Download