Pressure & Flow Monitor PFM Product Manual No part of this publication may be reproduced in any form whatsoever without the prior written approval of Netafim™. Netafim™ provides the information contained within “as is”. Netafim™ assumes no responsibility to persons or property resulting from any information contained within this book. Copyright Netafim™ 2008 PFM Product Manual Version 1.08 PFM Product Manual Contents Pressure & Flow Monitor ...................... 1 Introduction .......................................... 1 Power ON.............................................. 2 Measuring Pressure............................... 3 Measuring Flow .................................... 4 Selecting Mode & Scale ........................ 6 Power OFF............................................. 7 Replacing the Battery ........................... 8 PFM Product Manual Version 1.08 PFM Product Manual 1 Introduction The PFM Reader enables measurement of both water flow and pressure. Although the device measures both flow and pressure it can be operated in only one mode at a time. You must select which mode to use when first starting the device. Features • Flow Measurements (Gallons/minute or Liters/hour) • • • • • • Pressure Measurements Using NetafimTM pressure sensors, pressure can be measured in six different ranges, see page 6. Power ON/OFF Push button for manual ON/OFF. Automatic Power OFF Memory Mode When turned on the device remembers the mode it was last used in. Automatic Measurement In both Flow and Pressure operation modes the reader automatically displays the measurement. Low Battery Indication When 9V battery needs replacing “LOW BATT” is displayed. PFM Product Manual Version 1.08 PFM Product Manual • • • 2 No Pressure Indication When in pressure mode and either no pressure exists or a sensor is not connected, “No Pressure” is displayed. Version Display The version is displayed when the device is switched ON. Circuit Protection The pressure sensor is very sensitive to reverse polarity and voltage spikes. Protection is provided by a thermal fuse. Power ON Turn on the PFM Reader by pressing the ON/OFF button. As soon as the reader turns on the version number is displayed. PFM Product Manual Version 1.08 PFM Product Manual 3 Measuring Pressure Only NetafimTM pressure sensors can be used with this device. To measure pressure: 1. Connect the Switchcraft connector to the PFM reader as shown. 2. Select pressure mode and the correct scale for the reader (see page 6). The range for the pressure sensor is shown on its back. It is also indicated by the color on the heat shrink tubing on the cable. 3. In pressure mode, the reader measures pressure every 5 seconds. PFM Product Manual Version 1.08 PFM Product Manual 4 Measuring Flow In flow mode, the reader recalculates the value with the arrival of each pulse. Flow is measured in Gallons/minute or Liters/hour. The actual flow measurement L/h or G/m is actually the output of the meter according to pulses and you must adjust the value according to your water meter's rating. To measure flow: 1. Connect the water meter to the PFM reader as shown. 2. Select flow mode and the correct scale for the reader (see page 6). 3. In flow mode, the reader displays a new value with the arrival of each pulse. PFM Product Manual Version 1.08 PFM Product Manual 5 Some water meters provide different pulse rates. It's important to adjust the output rating according to your water meter's specifications. For example: Water meter A: PFM measurement = 25 pulse/h Meter output = 100 l/pulse Flow = 25 x 100 = 2500 L/h = 2.5 m3/h Water meter B: PFM measurement = 25 pulse/hour Meter output = 10 l/pulse Flow = 250 L/h = 0.25 m3/h Water meter C: PFM measurement = 25 pulse/minute Meter output = 0.1 g/pulse Flow = 25/10 = 2.5 G/m PFM Product Manual Version 1.08 PFM Product Manual 6 Selecting Mode & Scale The device operates in two modes: Flow and Pressure. It remembers the last mode it was used in. • • Flow can be measured in Liters/hour or Gallons/minute. Pressure can be measured in the following different ranges. The range for the pressure sensor is shown on its back. It is also indicated by the color of the heat shrink tubing. Bar PSI Heat Shrink 0-0.25 0-3.6 yellow 0-0.5 0-7.3 green 0-1 0-14.5 red 0-2 0-29 brown 0-6 0-87 blue Select the mode and scale by pressing the up and down arrow keys. PFM Product Manual Version 1.08 PFM Product Manual 7 Power OFF The PFM Reader features automatic Power OFF. In Flow Mode: • • The PFM Reader will automatically turn itself OFF after 7 minutes if irrigation is turned OFF. The PFM Reader will automatically turn itself OFF after 60 minutes if irrigation is turned ON. In Pressure Mode: • The PFM Reader will automatically turn itself OFF after 1 minute. You can manually turn the PFM Reader OFF by pressing the ON/OFF button until the reader shuts down. PFM Product Manual Version 1.08 PFM Product Manual 8 Replacing the Battery When the 9V battery needs replacing “LOW BATT” is displayed. Replace the battery as follows: 1. Remove the lid on the back of the PFM Reader by pressing down firmly on the arrow while sliding the cover open. 2. Remove the old battery and replace it with a new 9V battery. 3. Replace the cover. PFM Product Manual Version 1.08 www.netafim.com 08-1207-TLB-BK-0461-EN