SUITABLE FOR WET LOCATIONS
TYPE
PARADOX
JOB NAME
PART NO.
ARCHITECTURAL IN-GRADE
DESCRIPTION:
Model
Material
Lamp Type
Lens
Conduit
Accessories
Voltage
Lamp
Distribution
Options
Listing
Hydrel’s Paradox Series sealed modular in-grade luminaires are
multi-purpose units designed for up lighting architectural and landscape features. These units can be flush mounted into a variety of
substrates or landscape materials, and are ideal when aperture size
or luminaire depth is a priority.
SPECIFICATIONS:
DOOR MATERIAL: Die cast bronze or stainless steel.
HOUSING: Compression molded polyester with patent pending
internal direct access junction box for through-branch wiring. Internal junction box provides 44in3 volume to ensure proper seal during
installation. The housing is U.V. stabilized, impact and corrosion
resistant for use in all types of environments. The housing has a sidecar configuration and houses the lamp and power module components as well as the lens/ door finishing section.
LAMP TYPE:
Low Voltage:
MR11 GZ4 base, 35W max
MR16 GX5.3 base, 75W max
AR111 G53 base, 75W max
Incandescent: PAR20, PAR30, medium base
HID:
T-4 or T-6 bi-pin base, 70W max
PAR-20 or PAR-30 medium base, 70W max
Color Corrected Metal Halide
Fluorescent:
Triple tube CFL 4-pin base, 26W max
If a specific lamp is desired, specify manufacturer’s lamp number,
most lamps can be supplied. LAMP INCLUDED.
VOLTAGE: See ordering guide.
LIGHT DISTRIBUTION: Narrow spot through wide flood available.
See ordering guide for complete list of distribution options.
REFLECTORS: (Non-reflectorized lamps): High purity anodized
specular or semi-specular materials in various distributions provide
maximum performance and uniformity. Lamps can be aimed 15° from
vertical and rotated 360°. All configurations available with Hydrel’s
patented Aim-Lock® indexed and locking components to allow relamping and maintenance without re-aiming.
LENS/SEAL: Tempered clear flat borosilicate glass. The patent
pending door / lens seal uses proprietary knife edge technology to
secure the assembly to the housing. Three captive screws hold the
assembly in place. The lens is notched to provide maximum aperture
opening.
CONDUIT ENTRIES: Two molded ¾” NPT side entries standard,
bottom hubs are molded with a ¾” NPT membrane knockout.
ACCESSORIES: Decorative rock-guard, internal glare control, antislip lenses, and color filter options available. See ordering guide for
complete list of accessories.
BALLAST: Integrally mounted modular ballast package, prewired
with quick connectors for easy installation and maintenance. Ballasts
are rated for low starting temperatures. High power factor magnetic
ballasts standard, electronic ballasts also available.
FINISH: Natural bronze or stainless steel with a brushed finish.
APPROVALS
Bronze doors may be painted. Contact factory for color options.
LISTING: U.L., C.U.L
Hydrel is an ISO 9001
Certified Manufacturer
©2007 Acuity Brands Lighting, Inc.
Revised 6/26/08
PDX7 Rev_1
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION
WITHOUT NOTICE. Any dimension on this sheet is to be assumed as a
reference dimension: "Used for information purposes only. It does not
govern manufacturing or inspection requirements." (ANSI Y14.5-1973)
12881 Bradley Ave
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
www.hydrel.com
SUITABLE FOR WET LOCATIONS
PDX7 ORDERING INFORMATION
60 Hz Application
Choose the boldface catalog nomenclature that best suits your needs.
PART NO.
EXAMPLE:
PDX7 B
*Model
35CMT6
120
*Lamp Type
NSP
FLC
*Light Distribution
34S
RG
LPI
SF
*Conduit Entries
Low Voltage
† 34S Two 3/4"
† NSP Narrow Spot
*Lamp
NPT Side
†
M20 MR11 GZ4 base
†
SP Spot
(Standard)
†
M35 MR11 GZ4 base
† NFL Narrow Flood
†
LPI Lamp
† MFL Medium Flood
†
M50 MR16 GX5.3
Included
†
WFL
Wide
Flood
base
21
† FL Flood
†
M75 MR16 GX5.3
Accessories
Options
† WWD 7 Wall Wash
base
Distribution
Fusing
†
P3650 PAR36, screw
Internal
† SF 16 Single
terminal base
† IHL18 Internal
Fuse
†
P3675 PAR36, screw
honeycomb
† DF 17 Double
terminal base
louver
Fuse
† AR11135 G53 base
†
ISS8 Internal
Ballasting
† AR11150 G53 base
Source Shield
† GEB 6 Electronic
† AR11175 G53 base
† WWL 9 Wall wash
Ballast
2
Incandescent
internal louver
†
P2050I PAR20, med.
†
LSF Linear Spread
base
Filter
†
P3050I PAR30, med.
†CFAMB Color Filter
*Lens
*Material
*Voltage
base
Amber
† 12 3
P3075I PAR30, med.
† SS Stainless †
†
FLC Flat lens
† CFBLU Color Filter
†
120
base
Steel
Blue
clear
† 208
†BSS14 Brushed HID
14
† CFGRN Color Filter
4
†
FLCAS
Flat
Lens
†
220
Stainless † 20MHCP 10,12 PGJ5 base
Green
Clear, Anti† 240
Steel
† 20MHCG11,12 GU6.5 base
† CFRED Color Filter
† 277
Slip
† B Bronze † 20CMT412,13,19 T4 G8.5 base
Red
† 347
† FLCSR14 Flat Lens
† 35CMT412,13,19 T4 G8.5 base
6
External
†
MVOLT
12,13,19
Frosted,
† 70CMT4
T4 G8.5 base
†
RG Decorative
Slip
†
35CMT620 T6 G12 base
Rock guard
20
Resistant
†
70CMT6 T6 G12 base
†
P2035CM PAR20
medium
base
†
P3035CM PAR30
medium
*Required Categories
base
†
P3070CM PAR30
medium
base
†
R11135CM GX8.5
†
R11170CM GX8.5
Fluorescent 5
†
18TRT 15 Triple Tube,
GX24q2 base
†
26TRT 15 Triple Tube,
GX24q3 base
Notes:
9
1
Available only with WWD distributions and 18TRT, 26TRT lamps.
Low voltage only available in with 120, 240, 277
10
Philips Mini MasterColor available in 20W and 120V only.
inputs.
11
2
GE Mini UltraMax available in 20W and120V only.
Incandescent models are available with 120 Volt
12
Available with electronic ballast only.
only.
13
3
20CMT4, 35CMT4 or 70CMT4 only valid with MVOLT and GEB.
Available for Low Voltage lamps only.
14
4
Not available with Decorative Rock Guard.
220 only available with 70CMT6 & P3070CM.
15
5
Available only in MFL light distribution.
18TRT or 26TRT available with MVOLT only.
16
6
SF is only available with 120, 277 or 347 volts on HID only.
If GEB and a HID source is chosen, insert MVOLT.
7
Available with T4 G8.5 base, 20MH PGJ5 base, and 17 DF is only available with 208, 220 or 240 volts on HID only.
18
IHL not available with color filters.
20MH G46.5 base.
8
Available with T6 and T4 lamps in NSP distribution 19 Available with NSP, MFL and WWD only.
20
only. Not valid with WWD.
Available with NSP, MFL and WFL only.
Hydrel is an ISO 9001
21
Only available with PAR lamps.
Certified Manufacturer
† PDX7
1
©2007 Acuity Brands Lighting, Inc.
Revised6/26/08
PDX7 Rev_1
12881 Bradley Ave.
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
www.hydrel.com
SUITABLE FOR WET LOCATIONS
PDX7 ORDERING INFORMATION
50 Hz Application
Choose the boldface catalog nomenclature that best suits your needs.
PART NO.
EXAMPLE:
PDX7 B
*Model
35CMT6
23050HZ
*Lamp Type
† PDX7
Low Voltage1
†
M20 MR11 GZ4
base
†
M35 MR11 GZ4
base
†
M50 MR16 GX5.3
base
†
M75 MR16 GX5.3
base
†
P3650 PAR36, screw
terminal base
†
P3675 PAR36, screw
terminal base
† AR11135 G53 base
† AR11150 G53 base
† AR11175 G53 base
Incandescent 2
†
P2050I PAR20, E27
*Material
†
P3050I PAR30, E27
P3075I PAR30, E27
† SS Stainless †
HID
Steel
†BSS10 Brushed † 20CMT4 8,9,13 T4 G8.5 base
Stainless † 35CMT4 8,9,13 T4 G8.5 base
Steel
† 70CMT4 8,9,13 T4 G8.5 base
† B Bronze † 35CMT6 14 T6 G12 base
† 70CMT6 14 T6 G12 base
† P2035CM PAR20 E27
base
† P3035CM PAR30 E27
base
† P3070CM PAR30 E27
base
† R11135CM GX8.5
† R11170CM GX8.5
Fluorescent 4
†
18TRT 11 Triple Tube,
GX24q2 base
†
26TRT 11 Triple Tube,
GX24q3 base
NSP
FLC
25S
†
†
†
†
†
† 20S Two 20mm
Side
† 25S Two 25mm
Side
Narrow Spot
Spot
Narrow Flood
Medium Flood
Wide Flood
Flood
Wall Wash
Distribution
123
22050HZ
23050HZ
24050HZ
MVOLT5
SF
IEC
Listing
*Lamp
†
LPI Lamp
Included
Accessories
*Lens
*Voltage
LPI
*Conduit Entries
*Light Distribution
† NSP
† SP
† NFL
† MFL
† WFL
† FL15
†WWD
RG
†
FLC Flat lens
clear
† FLCAS10 Flat Lens
Clear,
Anti-Slip
† FLCSR10 Flat Lens
Frosted,
Slip
Resistant
Internal
† IHL12 Internal
honeycomb
louver
†
ISS6 Internal
Source Shield
† WWL 7 Wall wash
internal louver
†
LSF Linear Spread
Filter
†CFAMB Color Filter
Amber
† CFBLU Color Filter
Blue
† CFGRN Color Filter
Green
† CFRED Color Filter
Red
External
†
RG Decorative
Rock guard
†IEC International
Electrotechnical
Commission.
Options
Ballasting
† GEB 5 Electronic
Ballast
*Required Categories
Notes:
1
Low voltage only available in with 230, 240 inputs.
2
Incandescent models are available with 230 Volt
only.
3
Available for Low Voltage lamps only.
4
18TRT or 26TRT available with MVOLT only.
5
If GEB and a HID source is chosen, insert MVOLT.
6
Available with T6 and T4 lamps in NSP distribution
only. Not valid with WWD.
7
8
9
10
11
12
13
14
15
Available only with WWD distributions and 18TRT, 26TRT lamps.
Available with electronic ballast only.
20CMT4, 35CMT4 or 70CMT4 only valid with MVOLT and GEB.
Not available with Decorative Rock Guard.
Available only in MFL light distribution.
IHL not available with color filters.
Available with NSP, MFL and WWD only.
Available with NSP, MFL and WFL only.
Only available with PAR lamps.
Hydrel is an ISO 9001
Certified Manufacturer
©2007 Acuity Brands Lighting, Inc.
Revised 6/26/08
PDX7 Rev_1
12881 Bradley Ave.
Sylmar, CA 91342
Phone: 818-362-9465
Fax: 818-362-6548
www.hydrel.com
Download