• • • Studio Design Specifications – Recent Updates May 2014 – Added general clarification to specifications, replaced specs on lighting fixtures with LED, added Regency Lighting supplier contact info, updated Patcraft flooring representative contact info, April 2014 – Added Highland Forest LVT to replace previous spec, stipulated factory black ceiling tiles in place of P2-painted throughout studio except where noted, clarified door hardware in specific applications, specified all-black trim kits for recessed lighting, added flooring representative contact information, specified baseboards by-room, standardized interior door technical specs and removed option for upgrade, added standard power/data in break room for wall-mounted computer monitor, specified low-voltage punch down for linen room, added upgradeable plumbing fixtures and dispensers of restroom consumables, added specs for optional dedicated office, added specs for optional storage closet March 2014 – General Update – reconciled references and added spec sheets where applicable Studio Design Specifications Total Studio Area: 1600-1800 square feet Lobby: 280+ sq ft o Dimensions o o 14’ depth recommended minimum Walls o Wall separating lobby from rest of the space must be built full height to underside of roof deck o 5/8” Gyp. board standard o Sound batt insulation installed in all walls o For additional noise reduction add 5/8” sound board (Gold Bond® brand SoundBreak® or equal) in lieu of, or for best results, in addition to 5/8” sheet rock o Drywall level 4 finish or greater - Hamilton prep coat recommended Paint o Primary paint – P1 : Sherwin Williams #7527 Nantucket Dune (see spec – pg. 35) o Accent Paint – P2 : Sherwin Williams #6083 Sable (see spec – pg. 36) o All paints to be semi-gloss or egg shell. o Accent wall painted P2. Accent wall cannot be behind reception counter (recommend smallest wall.) All other walls P1. Floor o Contact Todd Stordahl, Patcraft Commercial Flooring Specialist, 303.775.1155 or todd.stordahl@patcraft.com o LVT (see spec – pgs. 14 – 15) o Franchise owner chooses between Ashwood, Walnut, or Barnwood finish. No substitutions. o 4” vinyl plank. Manufacturer: Patcraft • o Series: Highland Forest – 1200V Type B (Embosse) o Ashwood – 20100 o Walnut – 20700 o Barnwood – 20730 6” pine baseboard painted P2 Ceiling o Black 2’x2’ acoustical tiles and grid (see spec – pg. 11) o Factory black suspending ceiling tile and grid Page 1 of 52 Elements Massage Studio Design Specifications 5/2014 Armstrong - 24”x24”x5/8” Fine Fissured Tech Black inlay tiles or equal Black Mains – Armstrong 15/16” Black 7300 or equal Black Cross Tees – Armstrong XL7328-BL or equal o All HVAC diffusers, registers, grilles etc. Titus finish 84 factory black or equal o 10’-0” A.F.F. minimum – Support Center approval required if not standard o Sound batt insulation installed above suspended ceiling – 6¼”/R19 or greater recommended Lobby door: 3’x7’x1-3/4” full light/rain glass, MDF paint grade, Masonite or equal painted P2 semi-gloss o Knockdown hollow metal frame factory black o Push/pull non-latching passage dummy leverset in brushed nickel o Hydraulic door closer Power/data o (1) duplex outlet per wall, per corner o (2) quad outlets plus (2) data at reception desk o Additional outlets as needed per support center, franchise owner, or electrical code Lighting o Contact Brandon Melton, National Account Executive for Regency Lighting direct: 800.284.2024 ext. 4240, mobile: 303.748.8971, Email brandon.melton@regencylighting.com *Please note, all decorative light fixture specs are subject to change in the near future o (3) pendant lights (see spec – pgs. 16 – 17) on dedicated dimmer switch over the front desk Primary: Besa Lighting 1KX-412480-LED-BR • Cierro LED Pendant 1KX in 412480 Amber Matte with 10W GU-24 LED lamp (included) o 6” LED recessed can lights on dimmer switch with black baffle and trim ring Fixture: Elite B6IC-LED-14W-120V-DIM-FL-30K-AT (see spec – pg. 20) • Trim Kit: Elite L631P-BK (see spec – pg. 21) • o 6” New Construction IC Housing Phenolic Stepped Baffle (3) 6” LED recessed downlights on dimmer switch with black wall washer trim kits to shine on logo behind front desk Fixture: Elite Lighting HH6IC-LED-1200L-DIM10-120MD (see spec – pg. 22) • Trim Kit: Elite Lighting HH6-6507-MB-MB (see spec – pg. 23) • o Architectural High Lumen LED IC Downlight Wall Wash Reflector with Diffuse Lens – Matte Black Trim/Black Color Ring Ceiling fan (optional) Emerson 52” CF705BS fan or equal (see spec – pg. 12 – 13) GC to give allowance if alternate fan requested by franchise owner Page 2 of 52 Elements Massage Studio Design Specifications 5/2014 Pass through window (rain glass) installed between desk area and hallway or break room if applicable o Dimensions: Minimum 16”x 24”, maximum 24”x 24” o Lateral sliding pane on aluminum track with thumb-hold Hallway Walls o 5/8” Gyp. board standard o Sound batt insulation installed in all walls o For additional noise reduction add 5/8” sound board (Gold Bond® brand SoundBreak® or equal) in lieu of, or for best results, in addition to 5/8” sheet rock o Drywall level 4 finish or greater - Hamilton prep coat recommended o Painted P1 Sherwin Williams #7527 Nantucket Dune (see spec – pg. 29) Flooring o Contact Todd Stordahl, Patcraft Commercial Flooring Specialist, 303.775.1155 or todd.stordahl@patcraft.com o Carpet – CP1 (see spec – pgs. 30 – 31) o 2’ x 2’ Carpet Tile, installed with ¼ turn layout pattern Manufacturer: Patcraft • Series: #10096 Tweed Modular o o Color: #96102 Houndstooth 6” pine baseboard painted P2 Ceiling o Black acoustic ceiling tile and grid (see spec – pg. 11) All HVAC diffusers, registers, grilles etc. Titus finish 84 factory black or equal Same spec as lobby ceiling o 10’-0” A.F.F. minimum – Support Center approval required if not standard o Sound batt insulation installed above suspended ceiling – 6¼”/R19 or greater recommended Music System o o Speaker (see spec – pg. 32) Atlas C-series Model SD72 or equal Black, factory or painted Volume Control (see spec – pg. 33 – 34) Atlas AT35D or equal White or Ivory plate Dedicated volume control in each room Power (per code) Lighting Page 3 of 52 Elements Massage Studio Design Specifications 5/2014 o o 6” LED Recessed Can Lights (see spec – pg. 20 – 21) with black baffle and trim ring Every 10’-0” or per code Dedicated switch Same spec and source as lobby recessed cans Wall Sconces (see spec – pg. 18) Primary: Seagull Lighting 41585-710 • o One-Light Wall/Bath Sconce in Burnt Sienna with Café Tint Glass with LED Lamp Dedicated dimmer switch Installed alternating walls, between massage rooms or every 12’-0”, 82” to center A.F.F. • See hallway elevation example pg. 21 Massage Rooms: 96+ sq ft Dimensions o Minimum 8’ x 12’ o Couples’ Room Minimum 12’ x 14’ o Less than minimum requires Support Center approval Walls o 5/8” Gyp. board standard o Interior partitions to go ~6” above suspending ceiling, 3-5/8” metal studs, 3” high quality sound batt insulation, and 5/8” drywall o Partitions between massage rooms and lobby/break room/bathroom/linen framed full height to underside of roof deck For additional noise reduction may substitute Gold Bond® brand SoundBreak® or equal in lieu of 5/8” drywall o Drywall level 4 finish or greater - Hamilton prep coat recommended Paint o Primary paint – P1 : Sherwin Williams #7527 Nantucket Dune (pg. 35) o Accent Paint – P2 : Sherwin Williams #6083 Sable (pg. 36) o All paints to be semi-gloss or egg shell. o One accent wall in each massage room painted P2 – shortest wall; not the wall with the wall sconce. P1 all other walls. Floor o CP1 (see spec – pg. 30 – 31) o Same spec and source as hallway floor 4” Vinyl Cove Base (see spec – pg. 39 – 40) Roppe – 4” • 700 Series - 619 Java Page 4 of 52 Elements Massage Studio Design Specifications 5/2014 Ceiling o Black acoustic tile and grid (see spec – pg. 11) Same spec as lobby ceiling All HVAC diffusers, registers, grilles etc. Titus finish 84 factory black or equal o Air diffusers positioned not directly above massage table but offset toward foot of the table o (1) black speaker (see spec – pg. 32) located in middle of the room w/ dedicated volume control o 9’-0” A.F.F. minimum o Sound batt insulation installed above suspended ceiling – 6¼”/R19 or greater recommended Doors o 3’x7’x1-3/4” minimum, solid core, paint grade, Masonite or equal, painted P2 semi-gloss o Knockdown hollow metal frame factory black o Passage leverset in brushed nickel o Hydraulic door closer Power o (1) duplex outlet (standard height A.F.F.) located on the wall adjacent to the door o (1) duplex outlet (standard height A.F.F.) located in corner opposite the door. o (1) duplex outlet, recessed in middle of the floor, for massage table (floor trenching required) Lighting o o Wall sconce (see spec – pg. 18) centered on longest wall opposite door 82” A.F.F. to center Dimmer switch Same spec and source as hallway sconces (1) LED recessed can light (see spec – pg. 20 – 21) if required by permit or requested by owner with switch located next to sconce dimmer and volume control Break Room: minimum of 150 sq ft Break room will need to have room for at least a ¾ size refrigerator and 1-2 person work station with power and data Walls o 5/8” Gyp. board standard o 5/8” Green board at wet areas o Sound batt insulation installed in all walls o Drywall level 4 finish or greater o Painted P1 Floor o VCT (see spec – pg. 37 – 38) Armstrong – 12”x12” tile Page 5 of 52 Elements Massage Studio Design Specifications 5/2014 • o 51830 Cottage Tan 4” Vinyl Cove Base (see spec – pg. 39 – 40) Same spec as Massage Rooms Ceiling o Standard white 2’x2’ suspending ceiling tile and grid (see spec – pg. 11) Armstrong Prelude White 24”x24”x5/8” tiles or equal Armstrong Mains 15/16” 7300XR-White or equal Armstrong Cross Tees XL7328-WH or equal o All diffusers, registers, & grills to be white Titus finish 26 o 9’-0” A.F.F. minimum o Sound batt insulation installed above suspended ceiling – 6¼”/R19 or greater recommended Power o Per code - GFCI outlets as required o (2) duplex outlets between upper and lower cabinets o (2) duplex outlets near work station with data o (1) duplex outlet with data above or near work station 72” A.F.F. or as required for wall-mounted computer/tv monitor o Additional outlets at support center and/or franchise owner Lighting o Contact Brandon Melton, National Account Executive for Regency Lighting direct: 800.284.2024 ext. 4240, mobile: 303.748.8971, Email brandon.melton@regencylighting.com o 2’x2’ LED troffers and lighting on dedicated switch (see spec – pg. 24) Door o 3’x7’x1-3/4” minimum, solid core, paint grade, Masonite or equal, painted P2 semi-gloss o Knockdown hollow metal frame factory black o Push/pull non-latching passage dummy leverset in brushed nickel o Hydraulic door closer installed Linen Room: 40-80 sq ft (determined by the number of massage rooms) Walls o 5/8” Gyp. board standard o 5/8” Green board if applicable/required o Sound batt insulation installed in all walls o Level 4 finish or greater, Painted P1 Ceiling o Standard white 2’x2’ suspended ceiling tile and grid (see spec – pg. 11) Same spec as break room Page 6 of 52 Elements Massage Studio Design Specifications 5/2014 o 9’-0” A.F.F. minimum o Sound batt insulation installed above suspended ceiling – 6¼”/R19 or greater recommended Floor o VCT (see spec – pg. 37 – 38) and 4” vinyl cove base (see spec – pg. 39 – 40) same spec and source as break room floor Doors o 3’x7’x1-3/4” minimum, solid core, paint grade, Masonite or equal, painted P2 semi-gloss o Knockdown hollow metal frame factory black o Push/pull non-latching dummy leverset in brushed nickel o Hydraulic door closer installed Power o (2) GFCI duplex outlets o Punch down (low voltage) o Dynacom pre-wired 66 block with 12 2-pair RJ11 Jacks, Model DY-66BM12 – 2 or equal Separate 12-port CAT6 patch panel Intellinet Model #560269 or equal (for data) 220v dryer outlet (optional) Lighting o Contact Brandon Melton, National Account Executive for Regency Lighting direct: 800.284.2024 ext. 4240, mobile: 303.748.8971, Email brandon.melton@regencylighting.com o 2’x2’ LED troffers and lighting on dedicated switch (see spec – pg. 24) Plumbing o Mop sink and drain (per code) o Hot water heater (raised above ceiling ok); minimum 10 gallon o Washer hot/cold connection Utility Room (if required separate from Linen Room) Build and furnish all to linen room spec and per Code (2) ADA Bathroom compliant bathrooms Walls o 5/8” Green board o Sound batt insulation installed in all walls o For additional noise reduction add 5/8” sound board (Gold Bond® brand SoundBreak® or equal) in lieu of, or for best results, in addition to 5/8” sheet rock o P1 paint above tile o Drywall level 4 finish or greater Ceiling o Hard lid/drywall, painted P1, 8’-0” A.F.F. Page 7 of 52 Elements Massage Studio Design Specifications 5/2014 o LED recessed can light, on/off/motion switch o Same spec and source as lobby can lights Quiet operation exhaust fan Floor/Tile o Franchise owner chooses between light or dark option o Manufacturer: Daltile Series: Fidenza • Light: Bianco – FD01 (See spec pg 41 – 44) o • Dark: Café – FD02 (See spec pg 45 – 48) o o Grout: Poly Blend #382 Bone, or equal Grout: Poly Blend #22 Sahara Tan, or equal Tile size Floor – 18”x18” Wall – 9”x12” Bullnose – 3”x12” o Installed on floor and up walls 48” o Bullnose border tile on walls where appropriate o Decorative tile trim ok with support center approval, GC to provide allowance Doors o 3’x7’x1-3/4” minimum, solid core, paint grade, Masonite or equal, painted P2 semi-gloss o Knockdown hollow metal frame factory black o Privacy leverset in brushed nickel Fixtures o All fixtures must be ADA-compliant, installed per code o Water closet per spec (pg. 49) American Standard Cadet Flowise 2467.100 or equal, in white o Lavatory per spec (pg. 50 – 51) American Standard Lucerne model 0355.012 or equal, in white o upgrade ok with support center approval, GC to provide allowance upgrade ok with support center approval, GC to provide allowance Mirror per spec (pg. 52) Bobrick Model B-165-2436 or equal, stainless steel satin finish upgrade ok with support center approval, GC to provide allowance o Grab bars per code o Toilet paper and paper towel dispensers per code, upgrades supplied by franchise owner – to be discussed early enough to prevent unnecessary wall penetrations. Dedicated Office (if requested by owner) Walls o 5/8” Gyp. board standard Page 8 of 52 Elements Massage Studio Design Specifications 5/2014 o Same spec as massage rooms Partitions between office and lobby/break room/bathroom/linen framed full height to underside of roof deck, if applicable For additional noise reduction may substitute Gold Bond® brand SoundBreak® or equal in lieu of 5/8” drywall o Drywall level 4 finish or greater - Hamilton prep coat recommended Paint o Primary paint – P1 : Sherwin Williams #7527 Nantucket Dune (pg. 35) o All paints to be semi-gloss or egg shell. Floor o CP1 (see spec – pg. 30 – 31) and 4” Vinyl Cove Base (see spec – pg. 39 – 40) Same spec and source as massage room floor/base Ceiling o Black acoustic tile and grid (see spec – pg. 11) Same spec as lobby ceiling All diffusers, registers, & grills to be black Titus finish 84 o 9’-0” A.F.F. minimum o Sound batt insulation installed above suspended ceiling – 6¼”/R19 or greater recommended Doors o 3’x7’x1-3/4” minimum, solid core, paint grade, Masonite or equal, painted P2 semi-gloss o Knockdown hollow metal frame factory black o Privacy leverset in brushed nickel Power o Power and Data to support computer terminal, office equipment, or other as requested Lighting o LED recessed can lighting (see spec – pg. 24) if required by permit or requested by owner with switch located next to sconce dimmer Same spec and source as lobby can light Storage Closet (if required/requested) Walls o o 5/8” Gyp. board standard Same spec as massage rooms Painted P1 Wall-mounted wire shelving – 18” depth minimum, sized to fit Ceiling o Standard white 2’x2’ suspending ceiling tile and grid (see spec – pg. 11) Page 9 of 52 Elements Massage Studio Design Specifications 5/2014 9’-0” A.F.F. minimum Same spec as break room Doors o 3’x7’x1-3/4” minimum, solid core, paint grade, Masonite or equal, painted P2 semi-gloss o Knockdown hollow metal frame factory black o Privacy leverset in brushed nickel Lighting o 2’x2’ troffers and lighting on dedicated switch (see spec – pg. 24) Same spec and source as break room lighting Emergency/Egress Fixtures Contact Brandon Melton, National Account Executive for Regency Lighting for Regency Lighting direct: 800.284.2024 ext. 4240, mobile: 303.748.8971, Email brandon.melton@regencylighting.com Exit Signage as required by code o Exitronix GVEX-U-BP-LB-WH Thermoplastic combination LED Exit Emergency Lights as required by code o Exitronix TRL-EM-BR LED Emergency Light - Bronze Page 10 of 52 Elements Massage Studio Design Specifications 5/2014 Ceiling Tile Page 11 of 52 Elements Massage Studio Design Specifications 5/2014 Ceiling Fan Page 12 of 52 Elements Massage Studio Design Specifications 5/2014 Standard Ceiling Fan Technical Specs from Amazon.com Page 13 of 52 Elements Massage Studio Design Specifications 5/2014 LVT Flooring Page 14 of 52 Elements Massage Studio Design Specifications 5/2014 LVT Color Options Page 15 of 52 Elements Massage Studio Design Specifications 5/2014 Primary Pendant Light Page 16 of 52 Elements Massage Studio Design Specifications 5/2014 Page 17 of 52 Elements Massage Studio Design Specifications 5/2014 Primary Wall Sconce Page 18 of 52 Elements Massage Studio Design Specifications 5/2014 Hallway Elevation Example Page 19 of 52 Elements Massage Studio Design Specifications 5/2014 6” LED Recessed Can Light Page 20 of 52 Elements Massage Studio Design Specifications 5/2014 6” LED Recessed Can Light Trim Page 21 of 52 Elements Massage Studio Design Specifications 5/2014 6” LED Recessed Can Downlight – For Accent and Spot Lighting Page 22 of 52 Elements Massage Studio Design Specifications 5/2014 6” Recessed Downlight Directional Wall Washer Trim Page 23 of 52 Elements Massage Studio Design Specifications 5/2014 2’x2’ LED Troffer Page 24 of 52 Elements Massage Studio Design Specifications 5/2014 LED Exit Sign Page 25 of 52 Elements Massage Studio Design Specifications 5/2014 Page 26 of 52 Elements Massage Studio Design Specifications 5/2014 Page 27 of 52 Elements Massage Studio Design Specifications 5/2014 LED Emergency Light Page 28 of 52 Elements Massage Studio Design Specifications 5/2014 Page 29 of 52 Elements Massage Studio Design Specifications 5/2014 Carpet Page 30 of 52 Elements Massage Studio Design Specifications 5/2014 Page 31 of 52 Elements Massage Studio Design Specifications 5/2014 Music Speakers, Volume Controls, and Installation Instructions Page 32 of 52 Elements Massage Studio Design Specifications 5/2014 Page 33 of 52 Elements Massage Studio Design Specifications 5/2014 Page 34 of 52 Elements Massage Studio Design Specifications 5/2014 Primary Paint P1: Page 35 of 52 Elements Massage Studio Design Specifications 5/2014 Accent Paint P2 Page 36 of 52 Elements Massage Studio Design Specifications 5/2014 VCT Flooring Page 37 of 52 Elements Massage Studio Design Specifications 5/2014 Page 38 of 52 Elements Massage Studio Design Specifications 5/2014 Vinyl Cove Base Trim Page 39 of 52 Elements Massage Studio Design Specifications 5/2014 Page 40 of 52 Elements Massage Studio Design Specifications 5/2014 Light Option Floor Tile Page 41 of 52 Elements Massage Studio Design Specifications 5/2014 Light Option Wall Tile Page 42 of 52 Elements Massage Studio Design Specifications 5/2014 Light Option Bullnose Page 43 of 52 Elements Massage Studio Design Specifications 5/2014 Light Option Grout Page 44 of 52 Elements Massage Studio Design Specifications 5/2014 Dark Option Floor Tile Page 45 of 52 Elements Massage Studio Design Specifications 5/2014 Dark Option Wall Tile Page 46 of 52 Elements Massage Studio Design Specifications 5/2014 Dark Option Bullnose Page 47 of 52 Elements Massage Studio Design Specifications 5/2014 Dark Option Grout Page 48 of 52 Elements Massage Studio Design Specifications 5/2014 Toilet/Water Closet Page 49 of 52 Elements Massage Studio Design Specifications 5/2014 Wall-Hung Lavatory Page 50 of 52 Elements Massage Studio Design Specifications 5/2014 Page 51 of 52 Elements Massage Studio Design Specifications 5/2014 Bathroom Mirror Page 52 of 52 Elements Massage Studio Design Specifications 5/2014