Product Installation Instructions IMPORTANT SAFETY

advertisement
Product Installation Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of death, injury or property damage from fire, electric shock, cuts,
abrasions, falling parts, and other hazards:
• Service of the equipment must be performed by qualified service personnel.
• Installation and maintenance must be performed by a person familiar with the construction
and operation of this product and any hazards involved. All applicable codes and
ordinances must be followed.
• Read this document before installing, servicing, or maintaining this equipment or installing a
lamp. These instructions do not cover all installation, service, and maintenance situations.
If your situation is not covered, or if you do not understand these instructions or additional
information is required, contact Peerless Lighting or your local Peerless Lighting Distributor.
• Read and follow all warnings and instructions provided by the lamp manufacturer.
WARNING
Before installing, servicing, or maintaining this equipment, follow these general precautions.
To reduce the risk of electrocution:
• Make sure the equipment is properly grounded.
• Always de-energize the circuit and/or equipment before connecting to, disconnecting from,
or servicing the equipment.
To prevent fixture row from over-current:
• By adding the input current of each fixture section marked on the fixture, the total current
per power feed must not exceed the maximum line wire amperage marked on the fixture
and the power feed cord/wire amperage rating whichever the least.
To reduce the risk of fire:
• Keep material away that can burn from hot lamp.
• Make sure lamps are correctly installed.
• Use supply conductors with a minimum installation temperature rating as specified on
equipment.
To reduce the risk of personal injury from cuts, abrasions, or falling parts:
• Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton,
handling and maintaining this equipment.
• Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. These
substances may damage equipment and cause parts to eventually break and fall.
• Do not install a damaged fixture.
CAUTION: Observe lamp manufacturer’s recommendations and restrictions on lamp operation,
including but not limited to ballast type, burning position, replacement and cycling. Use only lamps that
comply with applicable ANSI standards.
NOTICE: If lamp is marked
it contains mercury. Follow disposal laws. See www.lamprecycle.org
Peerless Lighting, a division of Acuity Brands Lighting, Inc., assumes no responsibility for claims arising out of improper
or careless installation or handling of this product.
SAVE THESE INSTRUCTIONS
PEERLESS LIGHTING
P.O. Box 2556
Berkeley, CA 94702-0556
Phone: 510-845-2760 Fax: 510-845-2776
www.peerless-lighting.com
Part Number: PIN004100
Revision: B
Effectivity Date: 3/3/2008
PIN004200
CONTRAIL™ Pendant
PEERLESS LIGHTING
INDIRECT/DIRECT
INSTALLATION INSTRUCTION
P.O. BOX 2556, BERKELEY CA94702-0556
TEL: 510-845-2760 FAX: 510-845-2776
WEB SITE: WWW.PEERLESS-LIGHTING.COM
Rev.F 01/09 ECO 3533
These installation instructions are used for installing the following fixtures and kits:
Fixture
End-cap Kit
Configuration Kit
Lens Kit
CLM9
CLM9EP
CLM9 CNR
CLM9TNN
CLM9SHD
WARNING: Please read the "IMPORTANT SAFETY INSTRUCTIONS" prior to installation of this product
A) Cable Mounting Fixture Run Installation-------------------------------------------------------------------------------- page 1-2
B) OTM (On Tenon Mount) Installation for fixture configurations ------------------------------------------------------- page 3
C) Mounting Kit Accessories ----------------------------------------------------------------------------------------------------- page 3
A) Cable Mounting Fixture Row Installation
Adjustable Cable Option
1. Attach adjustable cable gripper (ACG)
to fixture and tighten securely.
Gripper
Fixture
Canopy
2. Insert cable into
ACG while
supporting the
weight of fixture.
4. Loosen screw,
then insert
cable ferrule.
Tighten screw.
3. Press down
here while
adjusting the
cable length.
1" MIN
With TNN
(OPTIONAL)
CNR
(OPTIONAL)
3" MAX
APPROX 1/2"
IMPORTANT
Do NOT insert cable into ACG prior to ACG
being attached to fixture. Twisting the cable
could cause gripper to become loose.
TNN
(OPTIONAL)
Page 1 of 4
PIN004200
CONTRAIL™ Pendant
INDIRECT/DIRECT
INSTALLATION INSTRUCTION
Rev.F 01/09 ECO 3533
X
(2)#6-32
screws
(1) #8-32 screw
1. Insert bushing & power cord through joiner/hanger on the
first fixture at the male connector end. Plug in the wire
connectors. Screw cable stud onto fixture hanger/joiner.
Discard a #10-24 screw present on the joiner where endcap will be installed.
2. Install end-cap with two (2) #6-32 flat head screws at the
top of the end cap, and (1) #8-32 screw present at the
bottom. Insert screw driver through the hole provided on
the end cap to tighten the #8 screw. Screw cable stud
onto joiner/hanger on the other end of the fixture. Raise
fixture into position.
X
X
Filler
3.
5.
Screw cable stud onto joiner/hanger for the second fixture
at the end with female connector. Raise the fixture into
position and connect wire connectors. Bolt fixtures with
two (2) #10-24 screws and with the filler in between.
Adjust the cable studs to level the fixtures. Repeat until the
last fixture is joined.
Install end-cap as Step 1 & 2 to complete the fixture row.
Level the whole fixture row. Tighten lock nuts on all fixed
cable studs to complete the housing and end cap installation.
4.
6.
Page 2 of 4
Remove weld stud, nut and discard the filler. Discard a
#10-24 screw present on the hanger/joiner where end cap
will be installed. Perform this step for the last fixture.
Remove two (2) #8-32 screws from the end shield present
on the lens kit. Insert lens assembly (lens kit) through
wireshieild present on the housing. Secure the lens
assembly with two (2) #8-32 screws.
PIN004200
CONTRAIL™ Pendant
INDIRECT/DIRECT
INSTALLATION INSTRUCTION
Rev.F 01/09 ECO 3533
B) OTM (On Tenon Mount) Installation
X
1.
TNN WITH OTM
TNN WITH OTM
(OPTIONAL)
(OPTIONAL)
Without using cable stud at fixture/TNN joint, refer
standard method shown on “Cable Mounting” Steps to
connect TNN to fixture. Install the adjustable cable grip
and cables to the TNN hanger and tighten it. Remove
weld stud, nut and discard the filler. Repeat same step for
CNR.
2.
Connect the wire connectors. Securely fasten the TNN to
the fixture joiner/hanger by using (2) #10-24 screws.
CNR WITH OTM
TNN WITH OTM
(OPTIONAL)
(OPTIONAL)
3.
Adjust the cable at TNN to level the fixtures. Refer the
rest standard steps to complete the fixture row.
C) Mounting Kit Accessories
4.
Repeat step 1. Unlike TNN attach the bracket to the
housing assembly using (2) #8 screws. Securely fasten
the CNR to the fixture joiner/hanger bracket by using (4)
#10-24 screws. Adjust the cable at CNR to level the
fixtures. Refer the rest standard steps to complete the
fixture row.
4
Mounting Kit Name (Accessories)
Fixed Cable
Adjustable cable
Used On
Support location at normal power feed
Support location at emergency power feed
Support location without power feed
CLMFK
CLMEK
CLMSK
Page 3 of 4
ACGPFK
ACGPEK
ACGPSK
PIN004200
CONTRAIL™ Pendant
INDIRECT/DIRECT
INSTALLATION INSTRUCTION
Rev.F 01/09 ECO 3533
D) Automatic Daylight Photo Dimming Option (DPC) Installation
1.
2.
Unfasten the knurl screw present on the photosensor.
Insert the photosensor into the end cap and fasten it using
the knurl screw. Install end-cap with two (2) #6-32 flat head
screws at the top of the end cap, and (1) #8-32 screw
present at the bottom. Insert the screw driver through the
hole provided to tighten the #8 screw. Rotate the sensor to
fasten the #8 screw if needed.
TNN WITH OTM
AND DPC
(OPTIONAL)
3.
Unfasten the knurl screw present on the photosensor.
Insert the photosensor into TNN hole and fasten using
the knurl screw. Adjust the cable at TNN to level the
fixtures. Refer the rest standard steps to complete the
fixture row. Repeat same steps for CNR.
4.
Page 4 of 4
Repeat step 6 in fixture run installation to install lens kit.
Download