Report No.: 14EAS03033 11
1
of 27
NO.L3098
EMC TEST REPORT
For Electromagnetic Interference of
Report Reference No........................:
14EAS03033 11
Date of issue.....................................:
2014-04-12
Testing Laboratory ............................:
ATT Product Service Co., Ltd.
No. 3, ChangLianShan Industrial Park, ChangAn Town,
DongGuan City, GuangDong, China.
Address.............................................:
Applicant’s name ..............................:
Address.............................................:
Manufacturer ....................................:
Mornsun Guangzhou Science &Technology Ltd.
No.5,Kehui St.1,Kehui development center,Science Ave.,
Guangzhou Science City,Luogang district,Guangzhou, P.R.
China
Mornsun Guangzhou Science &Technology Ltd.
Test specification:
Test item description.........................:
POWER SUPPLY
Trade Mark .......................................:
-A/B05XXS-2WR2
Refer to page 5 for details.
I/P: 5Vdc, 540mA
Model/Type reference .....................:
Ratings..............................................:
O/P: Refer to page 5 for details.
Responsible Engineer
Rock Huang / Engineer
ATT Product Service Co., Ltd (CBTL Lab of UL/Demko)
No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China.
Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn
Approved by
Tomy Wu /EMC Manager
Rev. 1.0
Report No.: 14EAS03033 11
2
of 27
NO.L3098
Table of Contents
Page
1 . CERTIFICATION
3
1.1. General product information:
4
2 . SUMMARY OF TEST RESULTS
5
2.1 MEASUREMENT UNCERTAINTY
6
2.2 DESCRIPTION OF TEST MODES
7
2.3 EQUIPMENT USED DURING TESTING:
8
2.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED
8
3 . EMC EMISSION TEST
3.1 RADIATED EMISSION MEASUREMENT
3.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT
3.1.2 MEASUREMENT INSTRUMENTS LIST
3.1.3 TEST PROCEDURE
3.1.4 DEVIATION FROM TEST STANDARD
3.1.5 TEST SETUP
3.1.6 EUT OPERATING CONDITIONS
3.1.7 TEST RESULTS
4 . EMC IMMUNITY TEST
9
9
9
10
10
10
11
11
12
17
4.1 STANDARD COMPLIANCE/SEVERITY LEVEL/CRITERIA AND CUSTOMER
REQUIREMENT
17
4.2 GENERAL PERFORMANCE CRITERIA
18
4.3 GENERAL PERFORMANCE CRITERIA TEST SETUP
18
4.4 ESD TESTING
4.4.1 TEST SPECIFICATION
4.4.2 MEASUREMENT INSTRUMENTS
4.4.3 TEST PROCEDURE
4.4.4 DEVIATION FROM TEST STANDARD
4.4.5 TEST SETUP
4.4.6 TEST RESULTS
19
19
19
19
20
20
21
4.5 RS TESTING
4.5.1 TEST SPECIFICATION
4.5.2 MEASUREMENT INSTRUMENTS
4.5.3 TEST PROCEDURE
4.5.4 DEVIATION FROM TEST STANDARD
4.5.5 TEST SETUP
4.5.6 TEST RESULTS
22
22
22
22
22
23
24
5 . EUT TEST PHOTO
ATT Product Service Co., Ltd (CBTL Lab of UL/Demko)
No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China.
Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn
25
Rev. 1.0
Test Report issued under the responsibility of:
NO.L3098
TEST REPORT
IEC/EN 60950-1
Information technology equipment – Safety –
Part 1: General requirements
Report Reference No. ......................:
14LAS03033 11
Date of issue.....................................:
Apr. 24, 2014
Total number of pages ......................
63 pages
CBTL Testing Laboratory ..............:
ATT Product Service Co., Ltd.
No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan
City, GuangDong, China.
Address ............................................:
Tested by (name + signature) ..... :
Henry Chen
Approved by (+ signature) ........... :
King Wang
Applicant’s name............................:
Mornsun Guangzhou Science &Technology Ltd.
Address ............................................:
5 KEHUI ST 1 KEHUI DEVELOPMENT CENTER, SCIENCE AVE,
GUANGZHOU SCIENCE CITY, LUOGANG DISTRICT, GUANGZHOU
GUANGDONG 510000 CHINA.
Manufacturer’s name .....................:
Same as applicant
Address ............................................:
Same as applicant
Test specification:
Test procedure .................................:
IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
(EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013)
LVD
Non-standard test method…………..:
N/A
Test Report Form No......................:
IEC60950_1F
Test Report Form(s) Originator ........:
SGS Fimko Ltd
Master TRF.......................................:
Dated 2014-02
Standard ...........................................:
Copyright © 2014 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE
is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due to
its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
ATT Product Service Co., Ltd (CBTL Lab of UL/Demko)
No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China
Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn
TRF No. IEC60950_1F
Report No.: 14LAS03033 11
2 of 63
NO.L3098
Test item description .....................:
DC-DC converter
Trade Mark .......................................:
Manufacturer ....................................:
Model/Type reference.......................:
Ratings .............................................:
Same as applicant
A05XXS-2WR2, B05XXS-2WR2 (XX=05, 09, 12, 15, 24 for output
voltage)
Input : 5Vdc, 540mA max.
Output: See model list on page 5
List of Attachments (including a total number of pages in each attachment):
- Photo documentation (4 pages)
Summary of testing:
Tests performed (name of test and test clause):
Testing location:
1. Following tests performed during evaluation:
All tests as described in Test Case and
Measurement Sections were performed at
the laboratory described on page 1.
Clause(s)
Test(s)
1.6.2
Input Current Test
1.7.11
Durability of Marking Test
2.1.1.5
Energy Hazard in Operator Access Area
2.9.2
Humidity Conditioning
4.5.1
Heating Test
4.5.5
Ball Pressure
5.1.6
Touch Current and PE current
5.2
Electric Strength Test
5.3
Fault Condition Test
All tests performed on models A0505S-2WR2, B0505S2WR2, A0509S-2WR2, A0512S-2WR2, A0515S-2WR2 and
A0524S-2WR2. Represented for all models.
The EUTs passed the test.
ATT Product Service Co., Ltd (CBTL Lab of UL/Demko)
No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China
Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn
TRF No. IEC60950_1F
Report No.: 14LAS03033 11
3 of 63
NO.L3098
Copy of marking plate:
The artwork below may be only a draft. The use of certification marks on a product must be authorized by
the respective NCBs that own these marks.
ATT Product Service Co., Ltd (CBTL Lab of UL/Demko)
No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China
Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn
TRF No. IEC60950_1F