Report No.: 14EAS03033 11 1 of 27 NO.L3098 EMC TEST REPORT For Electromagnetic Interference of Report Reference No........................: 14EAS03033 11 Date of issue.....................................: 2014-04-12 Testing Laboratory ............................: ATT Product Service Co., Ltd. No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China. Address.............................................: Applicant’s name ..............................: Address.............................................: Manufacturer ....................................: Mornsun Guangzhou Science &Technology Ltd. No.5,Kehui St.1,Kehui development center,Science Ave., Guangzhou Science City,Luogang district,Guangzhou, P.R. China Mornsun Guangzhou Science &Technology Ltd. Test specification: Test item description.........................: POWER SUPPLY Trade Mark .......................................: -A/B05XXS-2WR2 Refer to page 5 for details. I/P: 5Vdc, 540mA Model/Type reference .....................: Ratings..............................................: O/P: Refer to page 5 for details. Responsible Engineer Rock Huang / Engineer ATT Product Service Co., Ltd (CBTL Lab of UL/Demko) No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China. Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn Approved by Tomy Wu /EMC Manager Rev. 1.0 Report No.: 14EAS03033 11 2 of 27 NO.L3098 Table of Contents Page 1 . CERTIFICATION 3 1.1. General product information: 4 2 . SUMMARY OF TEST RESULTS 5 2.1 MEASUREMENT UNCERTAINTY 6 2.2 DESCRIPTION OF TEST MODES 7 2.3 EQUIPMENT USED DURING TESTING: 8 2.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 8 3 . EMC EMISSION TEST 3.1 RADIATED EMISSION MEASUREMENT 3.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT 3.1.2 MEASUREMENT INSTRUMENTS LIST 3.1.3 TEST PROCEDURE 3.1.4 DEVIATION FROM TEST STANDARD 3.1.5 TEST SETUP 3.1.6 EUT OPERATING CONDITIONS 3.1.7 TEST RESULTS 4 . EMC IMMUNITY TEST 9 9 9 10 10 10 11 11 12 17 4.1 STANDARD COMPLIANCE/SEVERITY LEVEL/CRITERIA AND CUSTOMER REQUIREMENT 17 4.2 GENERAL PERFORMANCE CRITERIA 18 4.3 GENERAL PERFORMANCE CRITERIA TEST SETUP 18 4.4 ESD TESTING 4.4.1 TEST SPECIFICATION 4.4.2 MEASUREMENT INSTRUMENTS 4.4.3 TEST PROCEDURE 4.4.4 DEVIATION FROM TEST STANDARD 4.4.5 TEST SETUP 4.4.6 TEST RESULTS 19 19 19 19 20 20 21 4.5 RS TESTING 4.5.1 TEST SPECIFICATION 4.5.2 MEASUREMENT INSTRUMENTS 4.5.3 TEST PROCEDURE 4.5.4 DEVIATION FROM TEST STANDARD 4.5.5 TEST SETUP 4.5.6 TEST RESULTS 22 22 22 22 22 23 24 5 . EUT TEST PHOTO ATT Product Service Co., Ltd (CBTL Lab of UL/Demko) No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China. Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn 25 Rev. 1.0 Test Report issued under the responsibility of: NO.L3098 TEST REPORT IEC/EN 60950-1 Information technology equipment – Safety – Part 1: General requirements Report Reference No. ......................: 14LAS03033 11 Date of issue.....................................: Apr. 24, 2014 Total number of pages ...................... 63 pages CBTL Testing Laboratory ..............: ATT Product Service Co., Ltd. No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China. Address ............................................: Tested by (name + signature) ..... : Henry Chen Approved by (+ signature) ........... : King Wang Applicant’s name............................: Mornsun Guangzhou Science &Technology Ltd. Address ............................................: 5 KEHUI ST 1 KEHUI DEVELOPMENT CENTER, SCIENCE AVE, GUANGZHOU SCIENCE CITY, LUOGANG DISTRICT, GUANGZHOU GUANGDONG 510000 CHINA. Manufacturer’s name .....................: Same as applicant Address ............................................: Same as applicant Test specification: Test procedure .................................: IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 (EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013) LVD Non-standard test method ..: N/A Test Report Form No......................: IEC60950_1F Test Report Form(s) Originator ........: SGS Fimko Ltd Master TRF.......................................: Dated 2014-02 Standard ...........................................: Copyright © 2014 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. ATT Product Service Co., Ltd (CBTL Lab of UL/Demko) No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn TRF No. IEC60950_1F Report No.: 14LAS03033 11 2 of 63 NO.L3098 Test item description .....................: DC-DC converter Trade Mark .......................................: Manufacturer ....................................: Model/Type reference.......................: Ratings .............................................: Same as applicant A05XXS-2WR2, B05XXS-2WR2 (XX=05, 09, 12, 15, 24 for output voltage) Input : 5Vdc, 540mA max. Output: See model list on page 5 List of Attachments (including a total number of pages in each attachment): - Photo documentation (4 pages) Summary of testing: Tests performed (name of test and test clause): Testing location: 1. Following tests performed during evaluation: All tests as described in Test Case and Measurement Sections were performed at the laboratory described on page 1. Clause(s) Test(s) 1.6.2 Input Current Test 1.7.11 Durability of Marking Test 2.1.1.5 Energy Hazard in Operator Access Area 2.9.2 Humidity Conditioning 4.5.1 Heating Test 4.5.5 Ball Pressure 5.1.6 Touch Current and PE current 5.2 Electric Strength Test 5.3 Fault Condition Test All tests performed on models A0505S-2WR2, B0505S2WR2, A0509S-2WR2, A0512S-2WR2, A0515S-2WR2 and A0524S-2WR2. Represented for all models. The EUTs passed the test. ATT Product Service Co., Ltd (CBTL Lab of UL/Demko) No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn TRF No. IEC60950_1F Report No.: 14LAS03033 11 3 of 63 NO.L3098 Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. ATT Product Service Co., Ltd (CBTL Lab of UL/Demko) No. 3, ChangLianShan Industrial Park, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-8509 8000; Fax: 86-769-8509 8777 E-mail:att@attps.cn TRF No. IEC60950_1F