APPENDIX 1:
CUT SHEETS
ENGINEERED
LIGHTING PRODUCTS
ID & IDTB SERIES
RECESSED 1´x 1´, 1´x 2´, 1´x 4´, 2´x 2´ and 2´x 4´ Indirect
Specifically designed for
computer environments
where minimum reflector
brightness is essential
and low ceiling contrast
ratios are required.
IR-10
ENGINEERED
LIGHTING PRODUCTS
ID & IDTB SERIES
RECESSED 1´x 1´, 1´x 2´, 1´x 4´, 2´x 2´ and 2´x 4´ Indirect
MINIMIZE
REFLECTED
IMAGE GLARE IN
VDT SCREENS
with a formed reflector
that allows no excessive
brightness above 55˚.
KEEP VISUAL
ACUITY SHARP
by shielding the lamp to
eliminate bare bulb
brightness directly over
the work station.
ENGINEERED
LIGHTING PRODUCTS
ELIMINATE
VEILING
REFLECTIONS
with diffused, indirect
light that allows even a
shiny printed page to
be read easily.
The reflector is
diffuse silver, high
purity aluminum with
a stepped crosssection. Concise
0.10˝ steps have a
sharp return angle
that presents a
clean light cut-off at
each step, assuring
no high angle glare.
Indirect
10768 LOWER AZUSA ROAD • EL MONTE • CA 91731 • 626-579-0943 • FAX: 626-579-6803 • E-mail: elp2@aol.com • WEB: www.elplighting.com
ENGINEERED
LIGHTING PRODUCTS
ID SERIES
E
MORLE!
W
NO RDAB
RECESSED 1´x 1´, 1´x 2´, 1´x 4´, 2´x 2´ and 2´x 4´
AFFO
Indirect for Plaster or Drywall
C
SYSTEM
Recessed, indirect 1´ x 1´, 1´ x 2´, 1´ x 4´, 2´ x 2´
and 2´ x 4´ fluorescent fixtures for plaster or drywall
installations. Available as a single or double lamp
unit for use with the 26 watt Quad, the 18, 40, 50 or
55 watt Biax, T-8 and T-5 linear lamps. Specifically
designed for computer environments where low
reflector brightness is essential.
UL/CUL Damp Location listed.
U.S. Patent #5,988,836
SPECIFICATIONS
Recessed, indirect 1´ x 1´, 1´ x 2´, 1´ x 4´, 2´ x 2´ and
2´ x 4´ fluorescent fixtures for plaster or drywall
installations. Available as a single or double lamp unit
for use with the 26 watt Quad, the 18, 40, 50 or 55
watt Biax, T-8 and T-5 linear lamps. The 4-1/2˝ or 6˝
deep housing has the lamp(s) centered at the bottom
plane of the fixture which is shielded such that the
lamp is not visible from any angle below the fixture.
The reflector is diffuse silver, high-purity aluminum
with a stepped cross-section. Concise 0.10˝ steps
have a sharp return angle that presents a clean
light cut-off at each step. Formed reflector will allow
no brightness in the area above 550 that exceeds
an average of 800 footlamberts. The reflector is
easily removable for access to the ballast and
wiring, and to re-lamp the 1´ wide fixtures.
The housing structure is 20 gauge CRS and is
post painted with a TGIC polyester powder coat.
Cover and knock-outs provided for pull-through
conductors with wiring space available within
fixture. Trim is extruded aluminum.
OPTIONS
Ballast
Finish
Reflector
Lamp Shield
Mini Lens
120 HPF Electronic (Standard)
277 HPF Electronic
Dimming (Some models) -DM
Emergency (Some models) -EPP
Magnetic -MG
White (Standard)
Custom -Custom
Stepped (Standard)
Brushed Aluminum -DS
Specular Silver (Standard)
Brushed Aluminum -BS
Lexan -ML-LEX
A
B
DE
2-5/8˝
C
All Single Lamp Section Fixtures
(and T-5 Double Lamp Section Fixtures)
A
Section
Model No.
126 QDID1
118 BXID1
140 BXID1
150 BXID1*
155 BXID1*
240 BXID1
250 BXID1*
255 BXID1*
140 BXID
150 BXID*
155 BXID*
240 BXID2†
250 BXID2*†
255 BXID2*†
240 BXID
250 BXID*
255 BXID*
440 BXID†
450 BXID*†
455 BXID*†
124 T-5ID1*
154 T-5ID1*
124 T-5ID*
224 T-5ID2*†
154 T-5ID*
254 T-5ID*†
117 T-8ID1
132 T-8ID1
117 T-8ID
217 T-8ID2†
132 T-8ID
232 T-8ID†
Front View
A
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
B
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
4-1/2˝
4-1/2˝
6˝
6˝
6˝
6˝
4-1/2˝
4-1/2˝
6˝
6˝
6˝
6˝
C
13-1/2˝
13-1/2˝
13-1/2˝
13-1/2˝
13-1/2˝
13-1/2˝
13-1/2˝
13-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
13-1/2˝
13-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
13-1/2˝
13-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
25-1/2˝
D
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
23-3/4˝
47-3/4˝
23-3/4˝
23-3/4˝
47-3/4˝
47-3/4˝
24-13/16˝
48-13/16˝
24-13/16˝
24-13/16˝
48-13/16˝
48-13/16˝
E
10-15/16˝
10-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
22-15/16˝
46-15/16˝
22-15/16˝
22-15/16˝
46-15/16˝
46-15/16˝
24˝
48˝
24˝
24˝
48˝
48˝
F
Lamp
13-1/2˝
26 watt Quad
13-1/2˝
18 watt Biax
25-1/2˝
40 watt Biax
25-1/2˝
50 watt Biax
25-1/2˝
55 watt Biax
49-1/2˝
(2) 40 watt Biax
49-1/2˝
(2) 50 watt Biax
49-1/2˝
(2) 55 watt Biax
25-1/2˝
40 watt Biax
25-1/2˝
50 watt Biax
25-1/2˝
55 watt Biax
25-1/2˝
(2) 40 watt Biax
25-1/2˝
(2) 50 watt Biax
25-1/2˝
(2) 55 watt Biax
49-1/2˝
(2) 40 watt Biax
49-1/2˝
(2) 50 watt Biax
49-1/2˝
(2) 55 watt Biax
49-1/2˝
(4) 40 watt Biax
49-1/2˝
(4) 50 watt Biax
49-1/2˝
(4) 55 watt Biax
25-1/2˝
24 watt T-5 HO
49-1/2˝
54 watt T-5 HO
25-1/2˝
24 watt T-5 HO
25-1/2˝ (2) 24 watt T-5 HO
49-1/2˝
54 watt T-5 HO
49-1/2˝ (2) 54 watt T-5 HO
26-9/16˝
17 watt T-8
50-9/16˝
32 watt T-8
26-9/16˝
17 watt T-8
26-9/16˝
(2) 17 watt T-8
50-9/16˝
32 watt T-8
50-9/16˝
(2) 32 watt T-8
Size
1´ x 1´
1´ x 2´
1´ x 4´
2´ x 2´
2´ x 4´
2´ x 2´ (T-8)
2´ x 4´ (T-8)
23-3/4˝
6˝
2˝
4˝
Double Lamp Section Fixtures
(Except T-5)
2´ x 2´ & 2´ x 4´ Only
F
2´ x 2´
© 2003 Engineered Lighting Products. 1996/Rev. 2003
Rough-In Dimensions
12-1/2˝ x 12-1/2˝
12-1/2˝ x 24-1/2˝
12-1/2˝ x 48-1/2˝
24-1/2˝ x 24-1/2˝
24-1/2˝ x 48-1/2˝
24-1/2˝ x 25-9/16˝
24-1/2˝ x 49-9/16˝
* Magnetic ballast not available
† Double lamp fixtures.
NOTE: Standard T-5 lamps are available: for
2´ fixtures, replace the “24” with “14”;
4´ fixtures, replace the “54” with “28.”
10768 LOWER AZUSA ROAD • EL MONTE • CA 91731 • 626-579-0943 • FAX: 626-579-6803 • E-mail: elp2@aol.com • WEB: www.elplighting.com
ENGINEERED
LIGHTING PRODUCTS
E
MORLE!
W
NO RDAB
AFFO
IDTB SERIES
RECESSED 1´x 1´, 1´x 2´, 1´x 4´, 2´x 2´ and 2´x 4´
Indirect for T-Bar Lay-In
SYSTEM
Recessed, indirect 1´ x 1´, 1´ x 2´, 1´ x 4´, 2´ x 2´
and 2´ x 4´ fluorescent fixtures for T-Bar ceilings.
Available as a single or double lamp unit for use
with the 26 watt Quad, the 18, 40, 50 or 55 watt
Biax and T-5 linear lamps. Specifically designed
for computer environments where low reflector
brightness is essential.
UL/CUL Damp Location Listed.
U.S. Patent #5,988,836
SPECIFICATIONS
Recessed, indirect 1´ x 1´, 1´ x 2´, 1´ x 4´, 2´ x 2´
and 2´ x 4´ fluorescent fixtures for T-Bar ceiling
installations. Available as a single or double lamp unit
for use with the 26 watt Quad, the 18, 40, 50 or 55
watt Biax and T-5 linear lamps. The 4-1/2˝ or 6˝ deep
housing has the lamp(s) centered at the bottom
plane of the fixture which is shielded such that the
lamp is not visible from any angle below the fixture.
The reflector is diffuse silver, high-purity aluminum
with a stepped cross-section. Concise 0.10˝ steps
have a sharp return angle that presents a clean
light cut-off at each step. Formed reflector will allow
no brightness in the area above 550 that exceeds
an average of 800 footlamberts. The reflector is
easily removable for access to the ballast and
wiring, and to re-lamp the 1´ wide fixtures.
The housing structure is 20 gauge CRS and is
post painted with a TGIC polyester powder coat.
Cover and knock-outs provided for pull-through
conductors with wiring space available within fixture.
OPTIONS
Ballast
Finish
Reflector
Lamp Shield
Mini Lens
120 HPF Electronic (Standard)
277 HPF Electronic
Dimming (Some models) -DM
Emergency (Some models) -EPP
Magnetic -MG
White (Standard)
Custom -Custom
Stepped (Standard)
Brushed Aluminum -DS
Specular Silver (Standard)
Brushed Aluminum -BS
Lexan -ML-LEX
A
C D
B
2-5/8˝
All Single Lamp Section Fixtures
(and T-5 Double Lamp Section Fixtures)
A
Section
Model No.
126 QDID-TB1
118 BXID-TB1
140 BXID-TB1
150 BXID-TB1*
155 BXID-TB1*
240 BXID-TB1
250 BXID-TB1*
255 BXID-TB1*
140 BXID-TB
150 BXID-TB*
155 BXID-TB*
240 BXID-TB2†
250 BXID-TB2*†
255 BXID-TB2*†
240 BXID-TB
250 BXID-TB*
255 BXID-TB*
440 BXID-TB†
450 BXID-TB*†
455 BXID-TB*†
124 T-5ID-TB1*
154 T-5ID-TB1*
124 T-5ID-TB*
224 T-5ID-TB2*†
154 T-5ID-TB*
254 T-5ID-TB*†
Front View
A
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
B
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
4-1/2˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
6˝
4-1/2˝
4-1/2˝
6˝
6˝
6˝
6˝
C
11-3/4˝
11-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
23-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
47-3/4˝
23-3/4˝
47-3/4˝
23-3/4˝
23-3/4˝
47-3/4˝
47-3/4˝
D
10-15/16˝
10-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
22-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
46-15/16˝
22-15/16˝
46-15/16˝
22-15/16˝
22-15/16˝
46-15/16˝
46-15/16˝
Lamp
26 watt Quad
18 watt Biax
40 watt Biax
50 watt Biax
55 watt Biax
(2) 40 watt Biax
(2) 50 watt Biax
(2) 55 watt Biax
40 watt Biax
50 watt Biax
55 watt Biax
(2) 40 watt Biax
(2) 50 watt Biax
(2) 55 watt Biax
(2) 40 watt Biax
(2) 50 watt Biax
(2) 55 watt Biax
(4) 40 watt Biax
(4) 50 watt Biax
(4) 55 watt Biax
24 watt T-5 HO
54 watt T-5 HO
24 watt T-5 HO
(2) 24 watt T-5 HO
54 watt T-5 HO
(2) 54 watt T-5 HO
* Magnetic ballast not available
† Double lamp fixtures.
NOTE: Standard T-5 lamps are available: for 2´ fixtures, replace the “24” with “14”;
4´ fixtures, replace the “54” with “28.”
23-3/4˝
6˝
2˝
4˝
Double Lamp Section Fixtures
(Except T-5)
2´ x 2´ & 2´ x 4´ Only
2´ x 2´
10768 LOWER AZUSA ROAD • EL MONTE • CA 91731 • 626-579-0943 • FAX: 626-579-6803 • E-mail: elp2@aol.com • WEB: www.elplighting.com
Recessed
Wall/Wash™
Highly effective for vertical
surface illumination, Recessed
Wall/Wash provides a very even
luminance ratio of 4 to 1 with
high illuminance levels and
minimum energy consumption.
Wide distribution and washing of
wall surfaces within several
inches of the floor and ceiling
makes Recessed Wall/Wash
perfect for stores, schools, offices,
and galleries with wall displays.
Recessed
Wall/Wash™
Asymmetric
Recessed Direct
G-D-1000
❍ Asymmetric recessed direct lighting for vertical surfaces
❍ 4 to 1 luminance ratio and high illuminance levels
❍ Clean ceiling appearance - no hardware hanging below the ceiling
❍ Perfect for retail, classroom, and other spaces with wall displays
SPECIFICATIONS
HOUSING. Die-formed and welded 20-gauge steel finished in baked Matte White enamel. Ends are notched to allow
installation in exposed inverted T-bar grid ceiling (NEMA type GF) with main T-bars at 2'-0" OC or 4'-0" OC. Exposed flanges
along the sides of the fixture support the ceiling tiles. The housing ends are provided with 7/8" diameter knockouts (1/2" trade
size). The top of the housing has an access opening covered by a plate containing two 7/8" diameter knockouts.
REFLECTOR. Die-formed .025" thick specular aluminum .
BALLAST. Electronic, high power factor, thermally protected Class P, Sound Rated A, 20% total harmonic distortion (THD) or
less, manufactured by Advance, ESI, Magnetek, Osram Sylvania (OSI) , or other UL Listed manufacturer, as available, determined by Litecontrol. The minimum number of ballasts will be used.
MOUNTING. The fixture is intended for installation in standard exposed inverted T-bar grid ceiling (NEMA type GF) with main
T-bars at 2'-0" OC or 4'-0" OC. Exposed flanges along the side of the fixture support the tiles. T-bar safety clips at the end of
the fixture shall be attached at the factory prior to shipping. 1/4" diameter holes have been provided, positioned at 90° to each
other, along the upper edges of the housing for installation of supplementary chain or wire support as may be required by
local codes. Estimated installed weight of 4-foot fixture is 20 lbs.
CERTIFICATION. Fixture and electrical components shall be UL and/or CUL Listed and shall bear the I.B.E.W., A.F. of L. label.
9 1/16"
(230)
4 3/4"
(121)
6 3/8"
(162)
10 1/2"
(267)
Section
Mounting
-
Distribution - Series
Lamp
Count
Nominal
Length (ft.)
Lamp
Type
-
Finish
-
Ballast
-
Option
-
Volts
Lamps
Length
in. (mm)
G
D
10
1
2
T8
CWM
ELB
1-F17T8
24 (610)
G
D
10
1
4
T8
CWM
ELB
1-F32T8
48 (1219)
G
D
10
2
2
T8
CWM
ELB
2-F17T8
24 (610)
G
D
10
2
4
T8
CWM
ELB
2-F32T8
48 (1219)
G
D
10
1
2
BX
CWM
ELB
1-FT40W
24 (610)
G
D
10
2
4
BX
CWM
ELB
2-FT40W
48 (1219)
G-D-1014T8-CWM-ELB-120 is a typical catalog number for a one-lamp, 4 foot long T8 fixture, painted Matte White, with electronic ballast, 120 volts.
Finish: CWM (Matte White) is standard.
For Photometric Data and Planning for Installation see G-D-1000 technical sheet for details.
BALLAST OPTIONS
OTHER OPTIONS
Specify in place of ELB, contact factory for availability/compatibility with lamping:
ELB10
Electronic ballast, same specification as above,
except less than 10% THD.
MKV/ELB
Advance Mark V electronic ballast.
DA-ELB
Advance Mark VII dimming ballast.
HEL/ELB
Motorola Helios dimming ballast.
ECO/ELB
Lutron ECO-10 dimming ballast.
EF
Cover Photography:
The Concord Book Shop, Concord, MA
Janovsky/Hurley Architects Inc., Lexington, MA
Charles Mayer, Photography
100 HAWKS AVENUE
. . . an employee owned company
HANSON
MA
02341
781 294 0100
F
RF
T2M, T2S
Emergency fluorescent ballast. Battery-powered ballast from
Bodine Corp. will operate one T8 lamp in a 4' or 8' fixture for 1 1/2 hours.
Fuse. HLR/GLR-size determined by Litecontrol.
HLR/GMF (slow blow) also available.
Radio frequency interference filter. Valmont 89G635,
unless otherwise specified.
Tandem ballasting. For energy considerations combine T2M
(Master) with T2S (Slave).
T2M - Fixture would contain one two-lamp ballast.
T2S - Fixture would not contain a ballast.
FAX 781 293 2849
info@litecontrol.com
www.litecontrol.com
© 2002 LITECONTROL, PDF 202
ORDERING GUIDE
TYPE:
CATALOG#:
DESCRIPTION
SPECIFICATION FEATURES
Low brightness 7 3/8" aperture
reflector for use with either
26W Quad tube 2-pin or 4-pin
compact fluorescents. The
precisely formed non-imaging
optical reflector ensures 45°
cutoff to lamp and lamp image
and the one piece design
eliminates light leaks at the
ceiling. Standard features
include low iridescent finish on
all reflector colors to eliminate
“rainbowing” and venting to
ensure maximum lamp life and
lumen output. Choice of
electronic or HPF magnetic
ballasts. Optics offer
unparalleled performance in
glare free lighting with a
smooth beam devoid of hot
spots.
spring clip mounting provides
nesting without light leaks in
outer housing. Other finish
options available upon request.
SPECIFICATION FEATURES
A ...R e f l e c t o r
One piece, .050 thick aluminum,
spun outer reflector in Low
Iridescent Alzak®, finished in
specular clear, haze, straw and
wheat. Positive reflector
mounting pulls trim tight to
ceiling. Upper inner reflector is
specular clear Alzak® for
maximum light output. Positive
PORTFOLIO
B ...T r i m R i n g O p t i o n s
High impact polymer with satin
white finish, metal trim, rimless
trim or self flanged reflector.
G ...J u n c t i o n B o x
Listed for eight #12AWG (four
in, four out) 90°C conductors
feed through branch wiring.
Four 1/2" and two 3/4" pry outs.
Positioned to allow straight
conduit runs. Access to junction
box by removing reflector.
H ...S o c k e t
C ...S o c k e t C a p
One piece vented and finned
die cast aluminum cap for
maximum thermal
performance.
D ...H o u s i n g M o u n t i n g F r a m e
One piece precision die cast
aluminum 1 1/2" deep collar
accommodates varying
dimensions of ceiling materials.
E ...U n i v e r s a l M o u n t i n g
Bracket
Accepts 1/2" EMT, C Channel, T
bar fasteners, and bar hangers.
Adjusts 5” vertically from
above or below ceiling.
F ...C o n d u i t F i t t i n g s
Die cast screw tight connectors.
2 pin G24d3 base or 4-pin
G24q3 with fatigue free
stainless steel lamp spring
ensures positive lamp retention.
I ...E l e c t r o n i c B a l l a s t
Thermally protected, fused,
encased and potted high
frequency electronic ballast
provides full light output and
rated lamp life. Provides flicker
free and noise free operation
and starting. End of lamp life
protection is standard.
Labels
2 6 W Q u a d
Compact
Fluorescent
7 3/8" NARROW
BEAM
OPEN REFLECTOR
U.L. listed,
C.S.A. certified,
standard damp label,
IBEW union made.
Energy Data
26W Quad 4-pin
Ballast: Electronic
120V Input Watts: 27
Line Amps: 0.22
277V Input Watts: 27
Line Amps: 0.09
Power Factor: >.99
THD: <10%:
Min Starting Temp.: -10°C (15°F)
Sound Rating: A
C ....................
Top View
H .........................
.........F
13 5/16"
[338mm]
I ........
A ..................
G .......
12 1/2"
[317mm]
13 7/8"
[352mm]
E .....
17"
[432mm]
C7726-7070
B .....
7 3/8" [187mm]
8 1/8" [209mm]
With EM Option
Ballast: HPF Magnetic
120V Input Watts: 35
Line Amps: 0.39
277V Input Watts: 28
Line Amps: 0.10
Power Factor: >.90
THD: <20%:
Min Starting Temp.: -5°C (23°F)
Sound Rating: A
26W Quad 4-pin
Ballast: Dimming
120V Input Watts: 27
Line Amps: 0.23
277V Input Watts: 27
Line Amps: 0.10
Power Factor: >.90
THD: <20%:
Min Starting Temp.: 10°C (50°F)
Sound Rating: A
D .....
17 5/8"
[448mm]
26W Quad 2-pin
8 3/4" [222mm]
Luminaire Efficacy Rating:
C7726-7070LI=51.82
ORDERING INFORMATION
SAMPLE NUMBER: C7726E-7070LI
Complete unit consists of housing, ballast and trim.
Housing
Ballast
Trims
Color
Accessories
C7726
C7726=7 3/8"
26W (1) Lamp
E, EEM*, ECP*=120V through 277V
7070=Reflector with
LI=Specular Clear,
Electronic
Polymer Trim
Low Iridescent
3E=347V Electronic
H=Haze
7071=Self Flanged
1H, 1HEM*=120V Magnetic HPF
S=Straw
Reflector
2H=277V Magnetic HPF
WH=Wheat
3H=347V Magnetic HPF
*EM=Emergency Module Option See ADV952040
1D,* 1DEM*,1DCP*=120V
*CP=Chicago Plenum Option See ADV953033
Dimming**
2D,* 2DCP*=277V Dimming**
** Lutron Hi-Lume ® or 100% compatible.
DLS1=120V to 277V Digital Lighting
Use with 4-pin lamps only
System (See DLS Section for
details)
COOPER LIGHTING
Trim Rings
TRM8P=White
TRM8-MB=Black
TRR8=White
NOTES:
Accessories should be ordered
separately.
For additional options please consult
factory.
Alzak is a registered trademark of
Aluminum Company of America.
Slope Ceiling Adapter
HSA-7-XX=Specify Slope
1 1/2” C-Channel Bar
Hangers
HB26=26” Long
HB50=50” Long
ADP012065
(Supersedes ADV985014)
C7726-7070
PHOTOMETRICS
Test No. H23189
C7726-7070
Open Reflector
Lamp=26W DTT
Lumens=1800
Spacing
Criterion=0.6
250
500
750
1000
Efficiency=54.7%
1250
Average
Luminance
Candlepower
Candlepower Distribution
1500
Deg.
CD
0
5
15
25
35
45
55
65
75
85
90
Deg.
45
55
65
75
85
1363
1353
942
633
372
96
5
0
0
0
0
Cone of Light
CD/SQ M
4294
316
0
0
0
Distance to
Illuminated Plane
Initial Nadir
Footcandles
4'6"
5'6"
6'6"
8'0"
10'0"
12'0"
Beam
Diameter
3'0"
3'6"
4'0"
5'0"
6'6"
8'0"
67
45
32
21
14
9
Beam diameter is to 50% of maximum footcandles, rounded
to the nearest half-foot.
Footcandle values are initial, apply appropriate light loss
factors where necessary.
Reflector
Multiplier:
Haze=.95
Straw=.9
Wheat=.9
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
090-180
0-180
Lumens
677
907
982
984
0
984
%Lamp
37.6
50.4
54.6
54.7
0.0
54.7
Coefficient of Utilization
%Luminaire
68.8
92.2
99.9
100.0
0.0
100.0
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
70
50
80%
30
10
50
70%
30
50%
10
50
65
65
65
65
64
64
64
61
62
61
60
59
60
59
58
58
60
58
56
54
57
55
54
55
58
55
52
51
54
52
50
53
55
52
49
47
51
49
47
50
53
49
46
44
49
46
44
48
51
47
44
42
46
44
42
45
48
44
41
39
44
41
39
43
46
42
39
37
41
39
37
41
44
39
37
35
39
36
35
39
42
37
35
33
37
34
33
37
rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio
CU Data Based on 20% Effective Floor Cavity Reflectance.
10
50
30%
10
50
10%
10
0%
0
61
56
53
49
47
44
41
39
37
34
33
58
56
54
51
49
47
45
43
40
38
36
58
55
51
49
46
43
41
39
37
34
32
56
54
52
50
48
46
44
42
40
38
36
56
53
50
48
46
43
41
39
36
34
32
55
52
50
47
45
42
40
38
36
34
32
Note: Specifications and Dimensions subject to change without notice.
Visit our website at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049
(Supersedes ADV985014) ADP012065
MODEL 01- 082
TWO-WAY ROOM & INDOOR GARAGE SENSOR
•
•
•
•
•
•
Automatic electronic lighting control.
Bi-directional pattern.
Full coverage. No gaps.
Replaceable circuit board.
Convenient and safe for occupants. Silent.
Compatible with GE or Sierra low voltage
remote control relays.
• Five-year warranty.
How It Operates:
The 01-082 is a motion sensor which controls lighting and other
electrical loads automatically based on the presence or absence of
people. It is designed for use in large office, classroom and indoor
garage spaces up to 2,100 square feet. The Novitas® Sensor
activates approved low voltage remote control relays which switch
the loads on and off. (See Power Requirements.)
The Sensor produces a low intensity, inaudible sound. It detects
changes in the sound waves caused by motion, such as reaching
for a telephone, turning the pages of a book, walking into a room,
turning in a swivel chair, etc. The Sensor does not respond to
audible sound. When the Sensor detects motion, a low voltage
pulse is transmitted to a relay which turns on the lights. If no
motion occurs within a pre-set period of time, the lights are turned
off. The time delay can be set from 15 seconds (for installer
testing) to 30 minutes. The recommended time delay is usually six
to eight minutes. People who remain very still for long periods may
need a longer time delay.
Special Features:
• Precisely-positioned fixed transducer angle makes installation
fast and accurate. No swivel to adjust. No accidental change in
coverage.
• Two frequencies are available to allow separate control of
adjacent areas.
• Crystal control provides consistent and stable performance.
Frequency variations will not exceed +0.005 percent.
• Four-relay control capability. 20 amps per relay. Enables use in
a wide range of applications.
• A manual override switch inside the Sensor allows the load to be
turned on quickly and easily should a Sensor ever malfunction.
No tool necessary.
• Snap-out circuit board allows fast, easy replacement without
affecting hard wiring or mounting.
• Teflon-insulated pigtails are fire rated for ceiling plenums.
Range & Coverage:
Approximately 2,100 square feet with dimensions of 36’ x 60’
(11.0m x 18.3m). See Coverage Diagrams. Multiple sensors may
be wired together for complete coverage of larger areas. If
partitions between 49 and 71 inches in height are present, use one
Sensor per 640 square feet. For greater partition heights, each
partitioned area should be treated as an individual space with floorto-ceiling walls. Range and coverage vary slightly according to
room shape and acoustics. In “soft” rooms with carpeting and
drapes, coverage may be reduced by approximately 15 percent.
An adjustable Range Control permits adaptation to different areas.
The NEMA WD 7 Guide and robotic method were utilized to verify
coverage patterns.
Mounting:
The Sensor mounts through a single 3/4” hole in the ceiling tile. All
hardware is provided. An adapter plate is available to allow
mounting to a standard fixture ring and junction box.
U.S. Letters Patent No. Des. 290,239
Multiple Frequencies:
Large open areas can be divided into individually-controlled spaces
without gaps in coverage. Each adjacent area can be independently controlled by using alternate frequency Sensors. Two
frequencies are available:
Frequency A = 25 KHz (Standard)
Frequency B = 27 KHz
Coverage is slighted reduced with Frequency B. (See Coverage
Diagrams.)
Wiring:
Novitas Sensors are provided with Teflon-insulated pigtails.
Sensors, relays and transformers are interconnected using 18
AWG Class 2 wiring per NEC 725. Use UL-recognized Teflonnsulated wire approved for plenum areas per NEC 725-2(b) where
required.
Power Requirements:
24 VAC + 10%
1 VA maximum for each Sensor
7 VA maximum for each GE RR7 type Relay
8.5 VA maximum for each Sierra 1070-B type Relay
Sensor is fused internally for maximum safety and protection.
CAUTION: Use only approved relays.
Output:
Half-wave rectified 24 VAC for 300 ms pulse for driving up to four
GE RR7 type Relays or up to two Sierra 1070-B type Relays.
Additional relays can be controlled when sensors are interconnected in a Master/Auxiliary configuration.
Housing:
Handsome design. Medium impact injection-molded housing.
ABS resin complies with UL 94V0. Sensor guard available.
Color:
Off-white. May be easily painted to match custom ceilings.
Size & Weight:
1-5/8” x 2-5/16” x 6-1/8” (41mm x 59mm x 156mm). HDW.
Approximately 5 oz. (142 g).
Installation Considerations:
The Sensor must have a clear view of the area to be controlled. It
should not be blocked from “seeing” people by high partitions. (For
partitioned areas, refer to Coverage Diagrams.) The Sensor will
not “see” through glass. Mounting height should be kept below 12
feet. Avoid pointing into hallways. To prevent false activation, the
Sensor should be mounted four feet away from the path of strong
air turbulence for standard sensitivity settings and at least six feet
away for maximum sensitivity settings. Not for use where temperao
o
tures fall below 32 F or exceed 100 F. For indoor use only. Note:
The life of some compact fluorescent lamps (CFLs) is shortened by
frequent automatic or manual switching. Check with CFL and
ballast manufacturer to determine effects of cycling.
c Novitas, Inc., 1986, 1990, 1991, 1995, 1997, 1998, 2000, 2002. All rights reserved.
MODEL 01- 082
Wiring Diagram
Sensor Controls
NEUTRAL
LINE
LOAD
HOT
MANUAL
“OFF”
SWITCH
(OPTIONAL)
Range
Minutes
RELAY
24 VAC
TO ADDITIONAL
RELAYS
(OPTIONAL)
(MAXIMUM OF 4
TOTAL)
NOTE: Use only
approved relays:
GE RR7 type or
Sierra 1070-B type.
Minimum
Sensitivity
Maximum
Sensitivity
15
30
Seconds
30
12
Minutes
TO
ADDITIONAL
SENSORS
WIRED AS
AUXILIARIES
(OPTIONAL)
01-082 SENSOR WIRED AS MASTER
01-082 SENSOR WIRED AS AUXILIARY
Standard Sensor Coverage Diagrams
NON-PARTITIONED AREAS
No partitions or partitions not to exceed 48” in height
PARTITIONED AREAS
Partition heights of 49” to 71”
17’
24’
25’
36’
56’
38’
60’
41’
Frequency B Sensor Coverage Diagrams
NON-PARTITIONED AREAS
No partitions or partitions not to exceed 48” in height
PARTITIONED AREAS
Partition heights of 49” to 71”
23’
16’
35’
24’
54’
36’
57’
39’
Half-step walk coverage
----------------------------Motion-at-desk coverage
Novitas, Inc., 370 Amapola Ave., No. 212, Torrance, CA 90501
(310) 218-5360 FAX (310) 218-5370
L1213
Lighting the Ceiling
Style 306
T5 Fluorescent
T8 Fluorescent
Small concealed, integral
Cove
1:8 Scale
A
B
C
D
3-3/4"
(95mm)
1:10 Scale
Sightline Angle
(see chart)
Maximum
Candlepower
(adjustable)
A
G
E
F
J
Style 306
Setback
(see
chart)
F
Lip Height
(see chart)
K
5-7/8"
(149mm)
Length (see chart)
1-1/8"
(29mm)
Width
(see chart)
Cove Dimensions
Joint
1:4 Scale
(Ballast compartment
not shown for clarity.)
(Max. candlepower aimed 15° above horiz.)
G
H
C
J
Nominal
Lamp
Length
1 x 2'
1 x 3'
1 x 4'
1 x 5'
2 x 3'
2 x 4'
2 x 5'
Luminaire
Length
T5
23-1/16" (586mm)
34-7/8" (886mm)
46-11/16" (1186mm)
58-1/2" (1486mm)
69-1/2" (1765mm)
93-1/8" (2365mm)
116-5/8" (2963mm)
T8
24-3/4" (628mm)
36-3/4" (932mm)
48-3/4" (1237mm)
60-1/2" (1537mm)
73-3/16" (1859mm)
97-3/16" (2468mm)
120-7/8" (3069mm)
Sightline
Width
(inside)
Lip
(inside)
Setback
(varies)
0°(horiz.
5°
10°
cutoff)
10-5/8" 8-1/4"
6-3/4"
(270mm) (210mm) (171mm)
3-3/4"
3"
2-5/8"
(95mm) (76mm) (67mm)
Recommended minimum:
10" T8, 12" T5, 18" T5HO
Note: Finish interior of cove matte white
for best results.
Specifications
A Specular extruded
aluminum reflector
B Stainless steel lampholder/support brackets
C Aluminum sidearm with
mounting tab
Features
D Extruded aluminum
ballast/wireway
channel cover
E Conduit entry (one
each end, conduit and
connector by others)
Extruded aluminum
ballast/wireway
compartment
G Rotation locking screw
H Joiner/alignment screw
F
Mounting tab (fastener
by others)
K Integral electronic
ballast
J
■ Choose T5 for precise optical control or widely utilized T8
■ Compact and flexible - effective indirect cove lighting for
malls, offices, lobbies, conference rooms and corridors
■ Adjustable - all reflectors in a row join and aim together;
rotation locking screws secure position*
■ Integral electronic ballast thru wiring for easy installation
Performance
Finish:
Reflector - extruded high purity aluminum with clear anodized
specular finish. Sidearms and ballast/ wireway compartment mill finish aluminum. All luminaire hardware - stainless steel.
Mounting:
Lay-in installation requires only one fastener per joint (by
others). Sidearms with mounting tabs can be base or wall
mounted. Luminaires can be mounted individually or joined
together to form a continuous row.
Reflector aiming is adjustable and is fixed in position by
rotation locking screws at each sidearm. When mounted in a
continuous row, joiner screws lock reflectors together allowing
all in the row to be aimed together.
Standard:
UL listed or CSA certified for damp locations.
(Style 151 smooth painted model with gasketed lens
recommended for damp location use; see Outdoor Section.)
REV. 12/02
*U.S. Patent No. 5,550,725 and foreign.
Electrical:
Use 90°C wire for supply connections.
Integral electronic HPF thermally protected class P ballast
(with end-of-life protection for T5 lamps). Ballast/wireway
compartment includes one conduit entry at each end.
Channel cover removes for access to ballast and wiring.
Luminaires may be butted end-to-end (connectors by others)
for through wiring.
Master/satellite combination is available (Configuration 3, see
ordering information). Master supplied with 2-lamp ballast.
(Wiring, conduit and connectors between master and satellite
units by others.)
Optional electronic dimming ballast dims to 1% of full light
output (5% for T8). Compatible dimming control is required
(by others). Consult sales representative for specifications.
Optional integral emergency battery operates one lamp.
Separate unswitched supply is required.
For complete ballast specifications, see Accessories Section.
Two parabolic reflector
sections drive light
across the ceiling from
one edge. An elliptical
section shields the lamp
from normal viewing
angles and redirects its
light to a parabola.
Glare is minimized and
asymmetry of the beam
is maximized resulting
in high beam efficiency
and superior surface
uniformity.
1x55W
T5 HO
1x32W
T8
2200
Cd
For complete photometrics, see Indoor Applications Section.
elliptipar
C
12.8
Style 306
To Order
Project:
To form a Catalog Number
F 3 0 6 1
2
-S -0 0 3
4
5
6
Type:
4 Mounting
7
8
1 Source
S = Sidearms with mounting tabs for base or wall
mounting
F = Linear fluorescent
5 Finish
2 Style
00 = Bright anodized reflector with mill finish ballast
compartment
306 = Small concealed, integral ballast
3 Lamp
Note: To order by overall row length, enter ROW CODE in
place of Lamp Code below (see Row Charts on page C-12.10
for T8 or C-12.12 for T5). Row Code specifies a row complete
with all necessary reflectors, brackets and ballasts.
= Lamp Code
Lamp Wattage (see chart below)
Reflector Configuration, specify 1, 2 or 3
(see chart below)
A = T8 Fluorescent
T = T5 Fluorescent
Example: A325 = two nominal 3' reflectors, each for use with
one 25W T8 lamp; one 2-lamp ballast
Reflector Configuration
1 - Lamp Ballast
1
C
12.9
1-Lamp Reflector
2 - Lamp Ballast
6 Voltage/Ballast
Electronic
1 = 120V
2 = 277V
Dimming *
T = 120V
V = 277V
* Dimming available for 3' F25T8 and 4' F32T8 (lamp codes A125,
A225, A132 and A232) and for 4' F55T5HO (lamp codes T155 and
T255). For other T8 and T5HO lamp lengths or for T5 standard
lamps, consult sales representative.
Dimming not available for Reflector Configuration 3.
7 Option (See Accessories Section for specifications)
00 = No options
0E = Integral emergency battery pack with indicator lamp
and test button. Operates one lamp. Available in
nominal 4', 6' and 8' units only (lamp codes A132,
A225, A232, A332, T128, T221, T228, T328, T155,
T239, T255 and T355).
XX = For modification not listed, include detailed
description. Consult factory prior to specification.
8 Standard
0 = UL, Underwriters Laboratories
J = CSA, Canadian Standards Association
2
2-Lamp Reflector
2 - Lamp Ballast
Example
3
1-Lamp Reflector (Master)
1-Lamp Reflector (Satellite)
Lamp Wattage
Lamp Length
(nominal)
2'
3'
4'
5'
Lamp Wattage (Lamp Number)
T8
T5
T5 HO
17 (F17T8)
14 (F14T5)
24 (F24T5/HO)
25 (F25T8)
21 (F21T5)
39 (F39T5/HO)
32 (F32T8)
28 (F28T5)
55 (F55T5/HO)
40 (F40T8)
35 (F35T5)
80 (F80T5/HO)
F306 - A240 - S - 00 - 1 - 0E0
Small concealed fluorescent consisting of one nominal 10'
luminaire, for use with two 40W T8 lamps. Integral 120V
electronic 2-lamp ballast. Sidearm with mounting tabs.
Supplied with integral emergency battery pack. UL.
For complete lamp and ballast information, see Accessories Section.
Standard T5 lamp color is 3000K / 80+ CRI. T8 lamps by others.
REV. 12/02
elliptipar
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
n
n
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. © 2002 elliptipar.
Lighting the Ceiling
Style 306
T8 Fluorescent
Small concealed, integral
Time saving - simplifies specification and ordering
One catalog number - includes all necessary reflectors
to install row
■ Assured fit - all you need is the clear inside length of the
ceiling slot or valance
■
■
REV. 3/02
Nominal Row Length in feet, between 3' and 50' **
* Not all lamp combinations are available for each nominal row length
(see chart)
** Nominal row lengths over 50' can be formed by combining shorter
row lengths. (Example: a nominal 60' row can be ordered as two
nominal 30' rows.)
Example
F306 - R16C - S - 00 - 2 - 000
Nominal 16' long row of Style 306 small concealed T8
fluorescent using only nominal 5' (40W) lamps. Row includes
one nominal 10' reflector for use with two 5' lamps, one
nominal 5' reflector for use with one 5' lamp, mounting
brackets and integral 277V electronic ballasts. Overall row
length is 15' 0-7/8".
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
3
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
A
B
C
A
D
B
F
A
G
C
D
D
F
A
B
D
F
G
D
F
G
C
D
B
F
D
F
G
A
D
F
G
D
F
G
Nominal 8' Luminaire
(2 x nominal 4' lamps)
4
5
6
7
8
9
9
10
10
11
11
12
12
13
13
14
14
14
15
15
15
16
16
17
17
18
18
18
19
19
19
19
20
20
20
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Lamp Combination*
A = All nominal 3' lamps
B = All nominal 4' lamps
C = All nominal 5' lamps
D = Nominal 3' and 4' lamps
F = Nominal 3' and 5' lamps
G = Nominal 4' and 5' lamps
Nominal 5' Luminaire
(1 x nominal 5' lamp)
= Row Code
R
Nominal 4' Luminaire
(1 x nominal 4' lamp)
Note: Enter row code in place of Lamp Code described on
page C-12.9.
Lamp
Combination
Features
3 Row Code
Nominal Row
Length (feet)
When the Style 306 small concealed fluorescent is run
continuously in a straight ceiling slot or valance, elliptipar
offers the option of specifying and ordering the entire row as
one catalog number. Ordering by row eliminates the need to
calculate length, type and quantity of reflectors.
Steps to specify Row Code:
1. Determine clear inside length of ceiling slot or valance.
2. Round up to nearest foot and find the nominal row length
in chart.
3. Determine what lengths/wattages of lamps will be used and
select the corresponding lamp combination codes.
Example: If only 3' and 4' lamps are to be used on the
project, specify row codes ending with A, B and/or D only.
4. If for a given nominal row length a preferred lamp
combination is not listed, select the next shorter row that is
available in the desired lamp combination.
5. Once the nominal row length and lamp combination has
been found in the chart, note the actual overall row length
(last column).
6. Consider the unlighted length at each end of the row.
(Subtract the overall row length from the clear inside length,
and divide the remainder by two.) It is generally
recommended that the unlighted length at each end be
between 6" and 12".
7. Enter the four character Row Code in place of the Lamp
Code described on page C-12.9. The remainder of the
catalog number is formed as shown on page C-12.9.
Nominal 3' Luminaire
(1 x nominal 3' lamp)
To order by Row Code - T8 lamps
3'-0 3/4"
4' 0-3/4"
5' 0-1/2"
6' 1-3/16"
7' 1-1/2"
8' 1-3/16"
8' 1-1/4"
9' 1-15/16"
9' 1-1/4"
10' 0-7/8"
10' 1-15/16"
11' 1-15/16"
11' 1-11/16"
12' 2-3/8"
12' 1-15/16"
13' 2-11/16"
13' 1-5/8"
13' 1-11/16"
14' 2-3/8"
14' 2-7/16"
14' 1-5/8"
15' 1-3/8"
15' 2-11/16"
16' 2-3/8"
16' 2-1/16"
17' 3-1/8"
17' 2-7/8"
17' 2-7/16"
18' 3-9/16"
18' 3-1/8"
18' 2-1/8"
18' 2-1/16"
19' 3-1/8"
19' 2-13/16"
19' 2-1/8"
elliptipar
C
12.10
REV. 3/02
1
1
1
3
1
1
2
1
1
1
1
1
2
2
1
2
1
1
3
1
1
1
1
1
1
1
2
2
2
2
1
1
2
1
4
1
1
1
1
1
2
1
2
2
1
1
1
1
3
1
3
1
1
1
1
1
1
1
2
1
2
2
2
2
1
5
3
1
1
1
1
1
1
3
2
3
1
2
1
2
1
20'-3 1/8"
20' 1-3/4"
21' 4-5/16"
21' 2-9/16"
21' 2-7/8"
22' 3-9/16"
22' 3-1/4"
22' 2-13/16"
23' 3-7/8"
23' 2-1/2"
23' 2-9/16"
24' 3-9/16"
24' 2-1/2"
25' 2-1/4"
25' 4-5/16"
25' 3-5/8"
26' 4-5/16"
26' 2-15/16"
26' 3-1/4"
27' 5-1/2"
27' 4-5/16"
27' 3-5/16"
28' 4-5/16"
28' 3"
28' 2-15/16"
29' 5-1/16"
29' 3-11/16"
29' 3"
30' 5-15/16"
30' 2-5/8"
30' 4-3/4"
30' 4"
31' 5-1/16"
31' 3-7/16"
31' 3-3/4"
elliptipar
elliptipar
4
2
1
1
1
1
2
2
5
1
1
1
1
1
3
1
1
3
2
2
3
3
1
1
1
4
6
1
4
1
1
1
1
1
2
3
1
2
2
4
4
1
1
1
1
1
1
3
2
3
3
6
1
1
4
1
3
5
4
1
1
1
1
1
1
2
1
1
3
4
3
4
7
1
2
4
4
3
1
32'-4 3/4"
32' 4-1/8"
32' 3-11/16"
33' 6-11/16"
33' 3-3/8"
33' 3-7/16"
34' 5-1/2"
34' 4-3/16"
34' 3-3/8"
35' 3-1/8"
35' 5-1/2"
36' 7-1/8"
36' 5-1/2"
36' 3-13/16"
36' 4-1/8"
37' 6-1/4"
37' 4-5/8"
37' 5-1/4"
38' 5-15/16"
38' 3-7/8"
38' 3-13/16"
39' 7-7/8"
39' 6-1/4"
39' 3-7/8"
40' 5-15/16"
40' 3-1/2"
40' 6-11/16"
41' 6-11/16"
41' 4-5/16"
41' 6"
42' 8-5/16"
42' 6-11/16"
42' 5"
42' 5-5/8"
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
■
■
1
1
5
1
1
5
1
1
1
1
1
4
3
3
4
1
7
1
1
4
1
1
1
2
5
1
1
5
5
1
1
2
1
4
3
3
3
8
6
1
1
1
1
1
1
1
1
1
5
4
4
4
4
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
D
F
G
B
F
G
A
C
G
D
F
G
D
F
G
A
B
F
G
D
F
G
Nominal 4' Luminaire
(1 x nominal 4' lamp)
44
44
44
45
45
45
46
46
46
47
47
47
48
48
48
49
49
49
49
50
50
50
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
B
F
G
A
F
G
D
F
G
C
D
A
B
F
G
D
F
G
D
F
G
A
D
G
B
C
D
D
F
G
A
D
F
G
Nominal 3' Luminaire
(1 x nominal 3' lamp)
33
33
33
34
34
34
35
35
35
36
36
37
37
37
37
38
38
38
39
39
39
40
40
40
41
41
41
42
42
42
43
43
43
43
Lamp
Combination
2
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
2
Nominal Row
Length (feet)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
Lamp
Combination
B
C
A
F
G
D
F
G
D
F
G
B
G
C
D
G
D
F
G
A
D
G
B
F
G
D
F
G
A
C
D
G
D
F
G
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Nominal Row
Length (feet)
C
12.11
21
21
22
22
22
23
23
23
24
24
24
25
25
26
26
26
27
27
27
28
28
28
29
29
29
30
30
30
31
31
31
31
32
32
32
Type:
Lamp
Combination
Project:
To form a Catalog Number
Style 306
Page 4 of 6
T8 Fluorescent
Small concealed
Nominal Row
Length (feet)
Lighting the Ceiling
43'-6 11/16"
43' 4-1/4"
43' 4-5/16"
44' 6-11/16"
44' 5-1/16"
44' 4-1/4"
45' 9-1/16"
45' 4"
45' 6-7/16"
46' 7-1/8"
46' 4-11/16"
46' 5"
47' 7-7/16"
47' 5-1/2"
47' 5-1/16"
48' 9-1/2"
48' 7-1/8"
48' 4-3/4"
48' 4-11/16"
49' 7-7/8"
49' 5-7/16"
49' 4-3/4"
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. © 2002 elliptipar.
Lighting the Ceiling
Style 306
T5 Fluorescent
Small concealed, integral
Time saving - simplifies specification and ordering
One catalog number - includes all necessary reflectors
to install row
■ Assured fit - all you need is the clear inside length of the
ceiling slot or valance
■
■
REV. 12/02
Nominal Row Length in feet, between 3' and 50' **
S = T5 fluorescent
V = T5 HO fluorescent
* Not all lamp combinations are available for each nominal row length
(see chart)
** Nominal row lengths over 50' can be formed by combining shorter
row lengths. (Example: a nominal 60' row can be ordered as two
nominal 30' rows.)
Example
F306 - S18G - S - 00 - 2 - 000
Nominal 18' long row of Style 306 small concealed T5
fluorescent using only nominal 4' (28W) and 5' (35W) lamps.
Row includes one nominal 10' reflector for use with two 5'
lamps, one nominal 8' reflector for use with two 4' lamps,
mounting brackets and integral 277V electronic ballasts.
Overall row length is 17' 5 3/4".
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
3
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
Overall
Row
Length
A
B
C
A
D
B
F
A
G
C
D
D
F
A
B
D
F
G
D
F
G
A
C
D
B
F
D
F
G
A
D
F
G
D
F
G
Nominal 10' Luminaire
(2 x nominal 5' lamps)
3
4
5
6
7
8
8
9
9
10
10
11
11
12
12
13
13
13
14
14
14
15
15
15
16
16
17
17
17
18
18
18
18
19
19
19
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Combination*
All nominal 3' lamps
All nominal 4' lamps
All nominal 5' lamps
Nominal 3' and 4' lamps
Nominal 3' and 5' lamps
Nominal 4' and 5' lamps
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Lamp
A =
B =
C =
D =
F =
G =
Nominal 5' Luminaire
(1 x nominal 5' lamp)
= Row Code
Nominal 4' Luminaire
(1 x nominal 4' lamp)
Note: Enter row code in place of Lamp Code described on
page C-12.9.
Lamp
Combination
Features
3 Row Code
Nominal Row
Length (feet)
When the Style 306 small concealed fluorescent is run
continuously in a straight ceiling slot or valance, elliptipar
offers the option of specifying and ordering the entire row as
one catalog number. Ordering by row eliminates the need to
calculate length, type and quantity of reflectors.
Steps to specify Row Code:
1. Determine clear inside length of ceiling slot or valance.
2. Round up to nearest foot and find the nominal row length
in chart.
3. Determine what lengths/wattages of lamps will be used and
select the corresponding lamp combination codes.
Example: If only 3' and 4' lamps are to be used on the
project, specify row codes ending with A, B and/or D only.
4. If for a given nominal row length a preferred lamp
combination is not listed, select the next shorter row that is
available in the desired lamp combination.
5. Once the nominal row length and lamp combination has
been found in the chart, note the actual overall row length
(last column).
6. Consider the unlighted length at each end of the row.
(Subtract the overall row length from the clear inside length,
and divide the remainder by two.) It is generally
recommended that the unlighted length at each end be
between 6" and 12".
7. Enter the four character Row Code in place of the Lamp
Code described on page C-12.9. The remainder of the
catalog number is formed as shown on page C-12.9.
Nominal 3' Luminaire
(1 x nominal 3' lamp)
To order by Row Code - T5 lamps
2' 10-7/8"
3' 10-11/16"
4' 10-1/2"
5' 9-1/2"
6' 9-9/16"
7' 9-1/8"
7' 9-3/8"
8' 8-3/8"
8' 9-3/16"
9' 8-5/8"
9' 8-3/16"
10' 8"
10' 8"
11' 7"
11' 7-13/16"
12' 7-1/16"
12' 7-1/2"
12' 7-5/8"
13' 6-5/8"
13' 6-7/8"
13' 7-5/16"
14' 5-7/8"
14' 7-1/8"
14' 6-11/16"
15' 6-1/4"
15' 6-1/8"
16' 5-1/2"
16' 5-1/2"
16' 6-5/16"
17' 4-1/2"
17' 5-5/16"
17' 6"
17' 5-3/4"
18' 5-1/8"
18' 5"
18' 5-13/16"
elliptipar
C
12.12
REV. 3/02
1
1
1
1
1
1
1
2
3
2
1
1
1
2
1
1
1
1
2
1
4
3
1
1
1
1
2
2
1
1
1
1
1
1
1
2
2
2
1
1
4
3
1
1
1
1
1
2
1
1
1
2
1
3
1
1
1
1
1
1
2
1
1
2
2
2
2
1
5
3
1
3
elliptipar
elliptipar
3
2
1
5
1
1
2
1
1
4
3
1
3
1
1
1
1
1
1
2
1
1
4
1
3
2
2
3
2
2
1
6
1
4
1
1
1
3
1
3
4
4
1
1
3
1
1
1
2
3
6
1
1
4
1
3
5
4
1
1
1
1
1
1
4
2
7
1
2
3
2
4
1
1
3
3
30'
30'
30'
31'
31'
31'
31'
31'
32'
32'
32'
33'
33'
33'
34'
34'
34'
35'
35'
36'
36'
36'
37'
37'
37'
38'
38'
39'
39'
39'
40'
40'
40'
40'
0-15/16"
1-1/4"
1-3/8"
10-3/8"
0-1/2"
11-3/4"
0-1/4"
1-1/16"
11-9/16"
0-3/4"
0-7/8"
11-3/8"
0-1/8"
0"
9"
11-3/16"
0-3/8"
10-7/16"
11"
10"
9-3/4"
11"
7-7/8"
10-1/16"
11-1/16"
9-5/8"
10-1/2"
8-7/8"
9-7/8"
10"
6-1/2"
8-11/16"
8-7/8"
9-11/16"
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
■
■
1
1
5
1
1
1
3
5
4
1
7
1
1
4
1
2
4
1
1
1
4
1
1
1
2
5
1
1
4
5
1
1
2
1
4
3
3
3
8
6
1
1
1
1
1
1
1
1
5
4
4
5
1
3
8
1
1
4
4
4
6
1
1
1
2
4
3
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
D
F
G
B
F
G
A
C
D
D
F
G
D
F
G
A
B
F
G
D
F
G
C
D
A
D
F
G
Nominal 5' Luminaire
(1 x nominal 5' lamp)
42
42
42
43
43
43
44
44
44
45
45
45
46
46
46
47
47
47
47
48
48
48
49
49
50
50
50
50
Nominal 4' Luminaire
(1 x nominal 4' lamp)
1
Nominal 3' Luminaire
(1 x nominal 3' lamp)
1
1
Overall
Row
Length
1
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 3' Luminaire
(1 x nominal 3' lamp)
D
F
G
A
B
D
F
G
D
F
G
D
F
G
A
B
C
D
G
D
F
G
A
D
G
B
C
D
F
G
A
D
F
G
Nominal 6' Luminaire
(2 x nominal 3' lamps)
3
1
1
31
31
31
32
32
32
32
32
33
33
33
34
34
34
35
35
35
36
36
37
37
37
38
38
38
39
39
40
40
40
41
41
41
41
Lamp
Combination
1
4-15/16"
5-1/4"
3-3/8"
4-3/16"
4-5/8"
4-3/4"
3-3/16"
3-5/8"
4-7/16"
3-13/16"
4-1/8"
4-1/4"
2"
3-3/8"
3-1/2"
3-15/16"
3-3/4"
2-5/8"
2-7/16"
2-3/4"
2-7/8"
0-7/8"
2-1/4"
2-1/8"
2-15/16"
2-1/16"
2-5/8"
2-3/8"
1-5/16"
1-5/8"
2-7/16"
11-1/2"
1-7/8"
0-7/8"
Nominal 5' Luminaire
(1 x nominal 5' lamp)
1
1
19'
19'
20'
20'
20'
20'
21'
21'
21'
22'
22'
22'
23'
23'
23'
23'
24'
24'
25'
25'
25'
26'
26'
26'
26'
27'
27'
27'
28'
28'
28'
28'
29'
29'
Lamp
Combination
2
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
2
Style 306
Type:
Nominal Row
Length (feet)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
B
C
A
D
F
G
D
F
G
D
F
G
A
B
F
G
C
D
D
F
G
A
D
F
G
B
F
G
D
F
G
A
C
D
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Lamp
Combination
C
12.13
Nominal Row
Length (feet)
Project:
20
20
21
21
21
21
22
22
22
23
23
23
24
24
24
24
25
25
26
26
26
27
27
27
27
28
28
28
29
29
29
30
30
30
Page 6 of 6
T5 Fluorescent
Small concealed
Nominal Row
Length (feet)
Lighting the Ceiling
41'
41'
41'
42'
42'
42'
43'
43'
43'
44'
44'
44'
45'
45'
45'
46'
46'
46'
46'
47'
47'
47'
48'
48'
49'
49'
49'
49'
8-1/2"
9-3/8"
9-3/16"
8-5/16"
7-1/4"
9-3/16"
5-3/8"
9"
7-9/16"
7-1/8"
8"
8-1/8"
7-3/16"
7-3/8"
8-3/16"
4"
6-3/4"
7-7/8"
7-5/8"
6"
6-7/8"
7-11/16"
7-1/8"
5"
2-7/8"
5-5/8"
6-1/2"
6-5/8"
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. ©2002 elliptipar.
Lighting the Ceiling
Style 306
T5 Fluorescent
T8 Fluorescent
Small concealed, integral
Cove
1:8 Scale
A
B
C
D
3-3/4"
(95mm)
1:10 Scale
Sightline Angle
(see chart)
Maximum
Candlepower
(adjustable)
A
G
E
F
J
Style 306
Setback
(see
chart)
F
Lip Height
(see chart)
K
5-7/8"
(149mm)
Length (see chart)
1-1/8"
(29mm)
Width
(see chart)
Cove Dimensions
Joint
1:4 Scale
(Ballast compartment
not shown for clarity.)
(Max. candlepower aimed 15° above horiz.)
G
H
C
J
Nominal
Lamp
Length
1 x 2'
1 x 3'
1 x 4'
1 x 5'
2 x 3'
2 x 4'
2 x 5'
Luminaire
Length
T5
23-1/16" (586mm)
34-7/8" (886mm)
46-11/16" (1186mm)
58-1/2" (1486mm)
69-1/2" (1765mm)
93-1/8" (2365mm)
116-5/8" (2963mm)
T8
24-3/4" (628mm)
36-3/4" (932mm)
48-3/4" (1237mm)
60-1/2" (1537mm)
73-3/16" (1859mm)
97-3/16" (2468mm)
120-7/8" (3069mm)
Sightline
Width
(inside)
Lip
(inside)
Setback
(varies)
0°(horiz.
5°
10°
cutoff)
10-5/8" 8-1/4"
6-3/4"
(270mm) (210mm) (171mm)
3-3/4"
3"
2-5/8"
(95mm) (76mm) (67mm)
Recommended minimum:
10" T8, 12" T5, 18" T5HO
Note: Finish interior of cove matte white
for best results.
Specifications
A Specular extruded
aluminum reflector
B Stainless steel lampholder/support brackets
C Aluminum sidearm with
mounting tab
Features
D Extruded aluminum
ballast/wireway
channel cover
E Conduit entry (one
each end, conduit and
connector by others)
Extruded aluminum
ballast/wireway
compartment
G Rotation locking screw
H Joiner/alignment screw
F
Mounting tab (fastener
by others)
K Integral electronic
ballast
J
■ Choose T5 for precise optical control or widely utilized T8
■ Compact and flexible - effective indirect cove lighting for
malls, offices, lobbies, conference rooms and corridors
■ Adjustable - all reflectors in a row join and aim together;
rotation locking screws secure position*
■ Integral electronic ballast thru wiring for easy installation
Performance
Finish:
Reflector - extruded high purity aluminum with clear anodized
specular finish. Sidearms and ballast/ wireway compartment mill finish aluminum. All luminaire hardware - stainless steel.
Mounting:
Lay-in installation requires only one fastener per joint (by
others). Sidearms with mounting tabs can be base or wall
mounted. Luminaires can be mounted individually or joined
together to form a continuous row.
Reflector aiming is adjustable and is fixed in position by
rotation locking screws at each sidearm. When mounted in a
continuous row, joiner screws lock reflectors together allowing
all in the row to be aimed together.
Standard:
UL listed or CSA certified for damp locations.
(Style 151 smooth painted model with gasketed lens
recommended for damp location use; see Outdoor Section.)
REV. 12/02
*U.S. Patent No. 5,550,725 and foreign.
Electrical:
Use 90°C wire for supply connections.
Integral electronic HPF thermally protected class P ballast
(with end-of-life protection for T5 lamps). Ballast/wireway
compartment includes one conduit entry at each end.
Channel cover removes for access to ballast and wiring.
Luminaires may be butted end-to-end (connectors by others)
for through wiring.
Master/satellite combination is available (Configuration 3, see
ordering information). Master supplied with 2-lamp ballast.
(Wiring, conduit and connectors between master and satellite
units by others.)
Optional electronic dimming ballast dims to 1% of full light
output (5% for T8). Compatible dimming control is required
(by others). Consult sales representative for specifications.
Optional integral emergency battery operates one lamp.
Separate unswitched supply is required.
For complete ballast specifications, see Accessories Section.
Two parabolic reflector
sections drive light
across the ceiling from
one edge. An elliptical
section shields the lamp
from normal viewing
angles and redirects its
light to a parabola.
Glare is minimized and
asymmetry of the beam
is maximized resulting
in high beam efficiency
and superior surface
uniformity.
1x55W
T5 HO
1x32W
T8
2200
Cd
For complete photometrics, see Indoor Applications Section.
elliptipar
C
12.8
Style 306
To Order
Project:
To form a Catalog Number
F 3 0 6 1
2
-S -0 0 3
4
5
6
Type:
4 Mounting
7
8
1 Source
S = Sidearms with mounting tabs for base or wall
mounting
F = Linear fluorescent
5 Finish
2 Style
00 = Bright anodized reflector with mill finish ballast
compartment
306 = Small concealed, integral ballast
3 Lamp
Note: To order by overall row length, enter ROW CODE in
place of Lamp Code below (see Row Charts on page C-12.10
for T8 or C-12.12 for T5). Row Code specifies a row complete
with all necessary reflectors, brackets and ballasts.
= Lamp Code
Lamp Wattage (see chart below)
Reflector Configuration, specify 1, 2 or 3
(see chart below)
A = T8 Fluorescent
T = T5 Fluorescent
Example: A325 = two nominal 3' reflectors, each for use with
one 25W T8 lamp; one 2-lamp ballast
Reflector Configuration
1 - Lamp Ballast
1
C
12.9
1-Lamp Reflector
2 - Lamp Ballast
6 Voltage/Ballast
Electronic
1 = 120V
2 = 277V
Dimming *
T = 120V
V = 277V
* Dimming available for 3' F25T8 and 4' F32T8 (lamp codes A125,
A225, A132 and A232) and for 4' F55T5HO (lamp codes T155 and
T255). For other T8 and T5HO lamp lengths or for T5 standard
lamps, consult sales representative.
Dimming not available for Reflector Configuration 3.
7 Option (See Accessories Section for specifications)
00 = No options
0E = Integral emergency battery pack with indicator lamp
and test button. Operates one lamp. Available in
nominal 4', 6' and 8' units only (lamp codes A132,
A225, A232, A332, T128, T221, T228, T328, T155,
T239, T255 and T355).
XX = For modification not listed, include detailed
description. Consult factory prior to specification.
8 Standard
0 = UL, Underwriters Laboratories
J = CSA, Canadian Standards Association
2
2-Lamp Reflector
2 - Lamp Ballast
Example
3
1-Lamp Reflector (Master)
1-Lamp Reflector (Satellite)
Lamp Wattage
Lamp Length
(nominal)
2'
3'
4'
5'
Lamp Wattage (Lamp Number)
T8
T5
T5 HO
17 (F17T8)
14 (F14T5)
24 (F24T5/HO)
25 (F25T8)
21 (F21T5)
39 (F39T5/HO)
32 (F32T8)
28 (F28T5)
55 (F55T5/HO)
40 (F40T8)
35 (F35T5)
80 (F80T5/HO)
F306 - A240 - S - 00 - 1 - 0E0
Small concealed fluorescent consisting of one nominal 10'
luminaire, for use with two 40W T8 lamps. Integral 120V
electronic 2-lamp ballast. Sidearm with mounting tabs.
Supplied with integral emergency battery pack. UL.
For complete lamp and ballast information, see Accessories Section.
Standard T5 lamp color is 3000K / 80+ CRI. T8 lamps by others.
REV. 12/02
elliptipar
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
n
n
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. © 2002 elliptipar.
Lighting the Ceiling
Style 306
T8 Fluorescent
Small concealed, integral
Time saving - simplifies specification and ordering
One catalog number - includes all necessary reflectors
to install row
■ Assured fit - all you need is the clear inside length of the
ceiling slot or valance
■
■
REV. 3/02
Nominal Row Length in feet, between 3' and 50' **
* Not all lamp combinations are available for each nominal row length
(see chart)
** Nominal row lengths over 50' can be formed by combining shorter
row lengths. (Example: a nominal 60' row can be ordered as two
nominal 30' rows.)
Example
F306 - R16C - S - 00 - 2 - 000
Nominal 16' long row of Style 306 small concealed T8
fluorescent using only nominal 5' (40W) lamps. Row includes
one nominal 10' reflector for use with two 5' lamps, one
nominal 5' reflector for use with one 5' lamp, mounting
brackets and integral 277V electronic ballasts. Overall row
length is 15' 0-7/8".
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
3
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
A
B
C
A
D
B
F
A
G
C
D
D
F
A
B
D
F
G
D
F
G
C
D
B
F
D
F
G
A
D
F
G
D
F
G
Nominal 8' Luminaire
(2 x nominal 4' lamps)
4
5
6
7
8
9
9
10
10
11
11
12
12
13
13
14
14
14
15
15
15
16
16
17
17
18
18
18
19
19
19
19
20
20
20
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Lamp Combination*
A = All nominal 3' lamps
B = All nominal 4' lamps
C = All nominal 5' lamps
D = Nominal 3' and 4' lamps
F = Nominal 3' and 5' lamps
G = Nominal 4' and 5' lamps
Nominal 5' Luminaire
(1 x nominal 5' lamp)
= Row Code
R
Nominal 4' Luminaire
(1 x nominal 4' lamp)
Note: Enter row code in place of Lamp Code described on
page C-12.9.
Lamp
Combination
Features
3 Row Code
Nominal Row
Length (feet)
When the Style 306 small concealed fluorescent is run
continuously in a straight ceiling slot or valance, elliptipar
offers the option of specifying and ordering the entire row as
one catalog number. Ordering by row eliminates the need to
calculate length, type and quantity of reflectors.
Steps to specify Row Code:
1. Determine clear inside length of ceiling slot or valance.
2. Round up to nearest foot and find the nominal row length
in chart.
3. Determine what lengths/wattages of lamps will be used and
select the corresponding lamp combination codes.
Example: If only 3' and 4' lamps are to be used on the
project, specify row codes ending with A, B and/or D only.
4. If for a given nominal row length a preferred lamp
combination is not listed, select the next shorter row that is
available in the desired lamp combination.
5. Once the nominal row length and lamp combination has
been found in the chart, note the actual overall row length
(last column).
6. Consider the unlighted length at each end of the row.
(Subtract the overall row length from the clear inside length,
and divide the remainder by two.) It is generally
recommended that the unlighted length at each end be
between 6" and 12".
7. Enter the four character Row Code in place of the Lamp
Code described on page C-12.9. The remainder of the
catalog number is formed as shown on page C-12.9.
Nominal 3' Luminaire
(1 x nominal 3' lamp)
To order by Row Code - T8 lamps
3'-0 3/4"
4' 0-3/4"
5' 0-1/2"
6' 1-3/16"
7' 1-1/2"
8' 1-3/16"
8' 1-1/4"
9' 1-15/16"
9' 1-1/4"
10' 0-7/8"
10' 1-15/16"
11' 1-15/16"
11' 1-11/16"
12' 2-3/8"
12' 1-15/16"
13' 2-11/16"
13' 1-5/8"
13' 1-11/16"
14' 2-3/8"
14' 2-7/16"
14' 1-5/8"
15' 1-3/8"
15' 2-11/16"
16' 2-3/8"
16' 2-1/16"
17' 3-1/8"
17' 2-7/8"
17' 2-7/16"
18' 3-9/16"
18' 3-1/8"
18' 2-1/8"
18' 2-1/16"
19' 3-1/8"
19' 2-13/16"
19' 2-1/8"
elliptipar
C
12.10
REV. 3/02
1
1
1
3
1
1
2
1
1
1
1
1
2
2
1
2
1
1
3
1
1
1
1
1
1
1
2
2
2
2
1
1
2
1
4
1
1
1
1
1
2
1
2
2
1
1
1
1
3
1
3
1
1
1
1
1
1
1
2
1
2
2
2
2
1
5
3
1
1
1
1
1
1
3
2
3
1
2
1
2
1
20'-3 1/8"
20' 1-3/4"
21' 4-5/16"
21' 2-9/16"
21' 2-7/8"
22' 3-9/16"
22' 3-1/4"
22' 2-13/16"
23' 3-7/8"
23' 2-1/2"
23' 2-9/16"
24' 3-9/16"
24' 2-1/2"
25' 2-1/4"
25' 4-5/16"
25' 3-5/8"
26' 4-5/16"
26' 2-15/16"
26' 3-1/4"
27' 5-1/2"
27' 4-5/16"
27' 3-5/16"
28' 4-5/16"
28' 3"
28' 2-15/16"
29' 5-1/16"
29' 3-11/16"
29' 3"
30' 5-15/16"
30' 2-5/8"
30' 4-3/4"
30' 4"
31' 5-1/16"
31' 3-7/16"
31' 3-3/4"
elliptipar
elliptipar
4
2
1
1
1
1
2
2
5
1
1
1
1
1
3
1
1
3
2
2
3
3
1
1
1
4
6
1
4
1
1
1
1
1
2
3
1
2
2
4
4
1
1
1
1
1
1
3
2
3
3
6
1
1
4
1
3
5
4
1
1
1
1
1
1
2
1
1
3
4
3
4
7
1
2
4
4
3
1
32'-4 3/4"
32' 4-1/8"
32' 3-11/16"
33' 6-11/16"
33' 3-3/8"
33' 3-7/16"
34' 5-1/2"
34' 4-3/16"
34' 3-3/8"
35' 3-1/8"
35' 5-1/2"
36' 7-1/8"
36' 5-1/2"
36' 3-13/16"
36' 4-1/8"
37' 6-1/4"
37' 4-5/8"
37' 5-1/4"
38' 5-15/16"
38' 3-7/8"
38' 3-13/16"
39' 7-7/8"
39' 6-1/4"
39' 3-7/8"
40' 5-15/16"
40' 3-1/2"
40' 6-11/16"
41' 6-11/16"
41' 4-5/16"
41' 6"
42' 8-5/16"
42' 6-11/16"
42' 5"
42' 5-5/8"
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
■
■
1
1
5
1
1
5
1
1
1
1
1
4
3
3
4
1
7
1
1
4
1
1
1
2
5
1
1
5
5
1
1
2
1
4
3
3
3
8
6
1
1
1
1
1
1
1
1
1
5
4
4
4
4
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
D
F
G
B
F
G
A
C
G
D
F
G
D
F
G
A
B
F
G
D
F
G
Nominal 4' Luminaire
(1 x nominal 4' lamp)
44
44
44
45
45
45
46
46
46
47
47
47
48
48
48
49
49
49
49
50
50
50
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
B
F
G
A
F
G
D
F
G
C
D
A
B
F
G
D
F
G
D
F
G
A
D
G
B
C
D
D
F
G
A
D
F
G
Nominal 3' Luminaire
(1 x nominal 3' lamp)
33
33
33
34
34
34
35
35
35
36
36
37
37
37
37
38
38
38
39
39
39
40
40
40
41
41
41
42
42
42
43
43
43
43
Lamp
Combination
2
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
2
Nominal Row
Length (feet)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
Lamp
Combination
B
C
A
F
G
D
F
G
D
F
G
B
G
C
D
G
D
F
G
A
D
G
B
F
G
D
F
G
A
C
D
G
D
F
G
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Nominal Row
Length (feet)
C
12.11
21
21
22
22
22
23
23
23
24
24
24
25
25
26
26
26
27
27
27
28
28
28
29
29
29
30
30
30
31
31
31
31
32
32
32
Type:
Lamp
Combination
Project:
To form a Catalog Number
Style 306
Page 4 of 6
T8 Fluorescent
Small concealed
Nominal Row
Length (feet)
Lighting the Ceiling
43'-6 11/16"
43' 4-1/4"
43' 4-5/16"
44' 6-11/16"
44' 5-1/16"
44' 4-1/4"
45' 9-1/16"
45' 4"
45' 6-7/16"
46' 7-1/8"
46' 4-11/16"
46' 5"
47' 7-7/16"
47' 5-1/2"
47' 5-1/16"
48' 9-1/2"
48' 7-1/8"
48' 4-3/4"
48' 4-11/16"
49' 7-7/8"
49' 5-7/16"
49' 4-3/4"
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. © 2002 elliptipar.
Lighting the Ceiling
Style 306
T5 Fluorescent
Small concealed, integral
Time saving - simplifies specification and ordering
One catalog number - includes all necessary reflectors
to install row
■ Assured fit - all you need is the clear inside length of the
ceiling slot or valance
■
■
REV. 12/02
Nominal Row Length in feet, between 3' and 50' **
S = T5 fluorescent
V = T5 HO fluorescent
* Not all lamp combinations are available for each nominal row length
(see chart)
** Nominal row lengths over 50' can be formed by combining shorter
row lengths. (Example: a nominal 60' row can be ordered as two
nominal 30' rows.)
Example
F306 - S18G - S - 00 - 2 - 000
Nominal 18' long row of Style 306 small concealed T5
fluorescent using only nominal 4' (28W) and 5' (35W) lamps.
Row includes one nominal 10' reflector for use with two 5'
lamps, one nominal 8' reflector for use with two 4' lamps,
mounting brackets and integral 277V electronic ballasts.
Overall row length is 17' 5 3/4".
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
3
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
Overall
Row
Length
A
B
C
A
D
B
F
A
G
C
D
D
F
A
B
D
F
G
D
F
G
A
C
D
B
F
D
F
G
A
D
F
G
D
F
G
Nominal 10' Luminaire
(2 x nominal 5' lamps)
3
4
5
6
7
8
8
9
9
10
10
11
11
12
12
13
13
13
14
14
14
15
15
15
16
16
17
17
17
18
18
18
18
19
19
19
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Combination*
All nominal 3' lamps
All nominal 4' lamps
All nominal 5' lamps
Nominal 3' and 4' lamps
Nominal 3' and 5' lamps
Nominal 4' and 5' lamps
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Lamp
A =
B =
C =
D =
F =
G =
Nominal 5' Luminaire
(1 x nominal 5' lamp)
= Row Code
Nominal 4' Luminaire
(1 x nominal 4' lamp)
Note: Enter row code in place of Lamp Code described on
page C-12.9.
Lamp
Combination
Features
3 Row Code
Nominal Row
Length (feet)
When the Style 306 small concealed fluorescent is run
continuously in a straight ceiling slot or valance, elliptipar
offers the option of specifying and ordering the entire row as
one catalog number. Ordering by row eliminates the need to
calculate length, type and quantity of reflectors.
Steps to specify Row Code:
1. Determine clear inside length of ceiling slot or valance.
2. Round up to nearest foot and find the nominal row length
in chart.
3. Determine what lengths/wattages of lamps will be used and
select the corresponding lamp combination codes.
Example: If only 3' and 4' lamps are to be used on the
project, specify row codes ending with A, B and/or D only.
4. If for a given nominal row length a preferred lamp
combination is not listed, select the next shorter row that is
available in the desired lamp combination.
5. Once the nominal row length and lamp combination has
been found in the chart, note the actual overall row length
(last column).
6. Consider the unlighted length at each end of the row.
(Subtract the overall row length from the clear inside length,
and divide the remainder by two.) It is generally
recommended that the unlighted length at each end be
between 6" and 12".
7. Enter the four character Row Code in place of the Lamp
Code described on page C-12.9. The remainder of the
catalog number is formed as shown on page C-12.9.
Nominal 3' Luminaire
(1 x nominal 3' lamp)
To order by Row Code - T5 lamps
2' 10-7/8"
3' 10-11/16"
4' 10-1/2"
5' 9-1/2"
6' 9-9/16"
7' 9-1/8"
7' 9-3/8"
8' 8-3/8"
8' 9-3/16"
9' 8-5/8"
9' 8-3/16"
10' 8"
10' 8"
11' 7"
11' 7-13/16"
12' 7-1/16"
12' 7-1/2"
12' 7-5/8"
13' 6-5/8"
13' 6-7/8"
13' 7-5/16"
14' 5-7/8"
14' 7-1/8"
14' 6-11/16"
15' 6-1/4"
15' 6-1/8"
16' 5-1/2"
16' 5-1/2"
16' 6-5/16"
17' 4-1/2"
17' 5-5/16"
17' 6"
17' 5-3/4"
18' 5-1/8"
18' 5"
18' 5-13/16"
elliptipar
C
12.12
REV. 3/02
1
1
1
1
1
1
1
2
3
2
1
1
1
2
1
1
1
1
2
1
4
3
1
1
1
1
2
2
1
1
1
1
1
1
1
2
2
2
1
1
4
3
1
1
1
1
1
2
1
1
1
2
1
3
1
1
1
1
1
1
2
1
1
2
2
2
2
1
5
3
1
3
elliptipar
elliptipar
3
2
1
5
1
1
2
1
1
4
3
1
3
1
1
1
1
1
1
2
1
1
4
1
3
2
2
3
2
2
1
6
1
4
1
1
1
3
1
3
4
4
1
1
3
1
1
1
2
3
6
1
1
4
1
3
5
4
1
1
1
1
1
1
4
2
7
1
2
3
2
4
1
1
3
3
30'
30'
30'
31'
31'
31'
31'
31'
32'
32'
32'
33'
33'
33'
34'
34'
34'
35'
35'
36'
36'
36'
37'
37'
37'
38'
38'
39'
39'
39'
40'
40'
40'
40'
0-15/16"
1-1/4"
1-3/8"
10-3/8"
0-1/2"
11-3/4"
0-1/4"
1-1/16"
11-9/16"
0-3/4"
0-7/8"
11-3/8"
0-1/8"
0"
9"
11-3/16"
0-3/8"
10-7/16"
11"
10"
9-3/4"
11"
7-7/8"
10-1/16"
11-1/16"
9-5/8"
10-1/2"
8-7/8"
9-7/8"
10"
6-1/2"
8-11/16"
8-7/8"
9-11/16"
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
■
■
1
1
5
1
1
1
3
5
4
1
7
1
1
4
1
2
4
1
1
1
4
1
1
1
2
5
1
1
4
5
1
1
2
1
4
3
3
3
8
6
1
1
1
1
1
1
1
1
5
4
4
5
1
3
8
1
1
4
4
4
6
1
1
1
2
4
3
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
D
F
G
B
F
G
A
C
D
D
F
G
D
F
G
A
B
F
G
D
F
G
C
D
A
D
F
G
Nominal 5' Luminaire
(1 x nominal 5' lamp)
42
42
42
43
43
43
44
44
44
45
45
45
46
46
46
47
47
47
47
48
48
48
49
49
50
50
50
50
Nominal 4' Luminaire
(1 x nominal 4' lamp)
1
Nominal 3' Luminaire
(1 x nominal 3' lamp)
1
1
Overall
Row
Length
1
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 3' Luminaire
(1 x nominal 3' lamp)
D
F
G
A
B
D
F
G
D
F
G
D
F
G
A
B
C
D
G
D
F
G
A
D
G
B
C
D
F
G
A
D
F
G
Nominal 6' Luminaire
(2 x nominal 3' lamps)
3
1
1
31
31
31
32
32
32
32
32
33
33
33
34
34
34
35
35
35
36
36
37
37
37
38
38
38
39
39
40
40
40
41
41
41
41
Lamp
Combination
1
4-15/16"
5-1/4"
3-3/8"
4-3/16"
4-5/8"
4-3/4"
3-3/16"
3-5/8"
4-7/16"
3-13/16"
4-1/8"
4-1/4"
2"
3-3/8"
3-1/2"
3-15/16"
3-3/4"
2-5/8"
2-7/16"
2-3/4"
2-7/8"
0-7/8"
2-1/4"
2-1/8"
2-15/16"
2-1/16"
2-5/8"
2-3/8"
1-5/16"
1-5/8"
2-7/16"
11-1/2"
1-7/8"
0-7/8"
Nominal 5' Luminaire
(1 x nominal 5' lamp)
1
1
19'
19'
20'
20'
20'
20'
21'
21'
21'
22'
22'
22'
23'
23'
23'
23'
24'
24'
25'
25'
25'
26'
26'
26'
26'
27'
27'
27'
28'
28'
28'
28'
29'
29'
Lamp
Combination
2
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
2
Style 306
Type:
Nominal Row
Length (feet)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
B
C
A
D
F
G
D
F
G
D
F
G
A
B
F
G
C
D
D
F
G
A
D
F
G
B
F
G
D
F
G
A
C
D
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Lamp
Combination
C
12.13
Nominal Row
Length (feet)
Project:
20
20
21
21
21
21
22
22
22
23
23
23
24
24
24
24
25
25
26
26
26
27
27
27
27
28
28
28
29
29
29
30
30
30
Page 6 of 6
T5 Fluorescent
Small concealed
Nominal Row
Length (feet)
Lighting the Ceiling
41'
41'
41'
42'
42'
42'
43'
43'
43'
44'
44'
44'
45'
45'
45'
46'
46'
46'
46'
47'
47'
47'
48'
48'
49'
49'
49'
49'
8-1/2"
9-3/8"
9-3/16"
8-5/16"
7-1/4"
9-3/16"
5-3/8"
9"
7-9/16"
7-1/8"
8"
8-1/8"
7-3/16"
7-3/8"
8-3/16"
4"
6-3/4"
7-7/8"
7-5/8"
6"
6-7/8"
7-11/16"
7-1/8"
5"
2-7/8"
5-5/8"
6-1/2"
6-5/8"
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. ©2002 elliptipar.
MODEL 01-BAS320
HIGH BAY SENSOR
• Automatic control for indoor high bay applications.
• Microprocessor-based Airflow Tolerant Technology.
• Two adjustable coverage zones for maximum savings
and placement flexibility.
• Avoids false activation from motion in cross-aisle.
• Compatible with High/Low HID and fluorescent.
• Immune to RFI, EMI and voltage fluctuations.
• BAS compatible.
• Five-year warranty.
How It Operates:
Designed specifically for use in indoor high bay applications like
warehouse aisles and gymnasiums, Model 01-BAS320 is an
ultrasonic motion sensor which controls lighting and other
electrical loads automatically based on the presence or absence of
people. Microprocessor-based Airflow Tolerant Technology
filters out the portion of the frequency spectrum related to air
movement to minimize false activations. The sensor activates a
Novitas® Switchpack to turn loads on and off.
When the Sensor detects motion, relays in all connected
Switchpacks are closed and lights are turned on. If no motion
occurs within a preset period of time, lights are turned off or
lowered, if two-level HID lamps or dimming ballasts are used.
Digital microprocessor-based circuitry allows time delay settings
from 15 seconds (for installer testing) to 30 minutes.
Separate sensitivity adjustments and two Switchpack outputs allow
for two coverage zones per aisle, simplifying placement. Twozone coverage also maximizes savings by lighting only the
occupied portion of the aisle and avoiding false activation from
cross-aisle occupancy. Separate LEDs indicate which side of the
Sensor detected motion.
When connecting to a BAS, the 01-BAS320 Warehouse Aisle
Sensor offers the most versatile connection possibilities available
including an open collector output with or without pull-up feature
and a direct BAS connection. See Power Requirements and
Wiring Diagram.
Special Features:
• Self-adjusts sensitivity in real-time to optimize performance.
• Coverage remains stable regardless of environmental
conditions.
• High/Low HID function forces HID lamps into “high” mode for the
first 20 minutes to ensure sufficient warm-up.
• Selectable slide switch enables sensor to convert from High/Low
HID lighting to fluorescent on/off capability.
• Lighting sweep delay function prevents unnecessary activation
of lights in unoccupied areas as a result of “power up.”
• Internal pull-up option simplifies BAS interface.
• Airflow Tolerant Technology resists false activation in high
airflow environments.
• Simplifies installation with 10-minute time delay default when
potentiometer is left at minimum setting.
• Slide switch permits override should a Sensor ever fail. Open
door allows override mode to be detected easily.
• Snap-out circuit board for fast, easy replacement without
affecting hard wiring or mounting.
• Multiple frequencies enable separate control of adjacent areas.
• Crystal control provides consistent and stable performance.
Frequency variations will not exceed +0.005 percent.
Range & Coverage:
Coverage with maximum dimensions of 80x10 linear feet (up to
40x10 lin. ft. in each direction) at a height of 30 feet. Coverage is
reduced for heights above 30’. Multiple Sensors may be used for
long aisles. Five Sensors may be connected to each Switchpack.
Patent Pending
Mounting:
Versatile mounting scheme. Sensor mounts through a 3/4” hole
in the ceiling tile using provided hardware, to a standard 2S or 4S
junction box for hard ceilings, or to the surface.
Multiple Frequencies:
In warehouse applications, adjacent aisles can be isolated from
each other by using alternate frequencies. This prevents false
activation of lighting in adjacent areas where no solid partitions
are present. Two frequencies are available:
Frequency A = 25 KHz (Standard)
Frequency B = 27 KHz
Coverage is slightly reduced with frequency B (see Coverage
Diagrams).
Wiring:
Novitas Sensors are provided with extra-long, 16-inch Teflon
insulated pigtails, for increased flexibility during installation.
Sensors and Switchpacks are interconnected using 18 AWG class
2 wiring per NEC 725. Use UL-recognized Teflon insulated wire
for plenum areas per NEC 725-2(b) where required.
Power Requirements:
15 VDC from Novitas Switchpack. Up to five Sensors may be
powered by one Novitas Switchpack. Direct connection to a
Building Automation System is possible if the BAS provides
between 10 and 30 VDC at 25mA. Sensor circuit includes jumper
selectable pull-ups which enable the BAS to recognize the
sensor’s open collector output.
Output:
Two Switchpack outputs permit separate control of each portion
of the aisle. They can also be combined to control the warehouse
aisle as a single zone. If controlled as a single zone, up to 10
Novitas Switchpacks can be connected to one Sensor. If
controlled as two zones, up to 10 Switchpacks can be connected
together per zone for a maximum limit of 20 Switchpacks.
Housing:
Impact-resistant injection molded housing in off-white. ABS resin
complies with UL 94V0. Protective Sensor Guard available.
Size & Weight:
1-11/16” x 3-7/8” x 6-3/8” (4mm x 99mm x 162mm) HDW.
Approximately 6.9 oz. (196g).
Installation Considerations:
To prevent false activation, the Sensor should not be mounted in the
path of strong air turbulence. Not for use where temperatures fall
below 32o F. Coverage reduced if temperatures exceed 100o F. For
indoor use only. Note: The life of some compact fluorescent lamps
(CFLs) is shortened by frequent automatic or manual switching. Check
with CFL and ballast manufacturer to determine effects of cycling.
c Novitas, Inc. 1998, 1999, 2002. All rights reserved.
MODEL 01-BAS320
Wiring Diagram for Controlling
Fluorescent On/Off Lamps
Printed Circuit Board Diagram
*Use ONLY ONE Manual Off Switch Option per Switchpack
LINE VOLTAGE
Range
Time Delay
Slide Switch
Pull-up
Shunt
(JP2)
Range
HOT**
HOT**
Pull-up
Shunt
(JP1)
Lighting Sweep Shunt (JP3)
Potentiometers
Directly to a BAS System when 10-30 VDC,
25 mA is available. (Do not use Switchpack.)
Sensor provides two separate, jumper
selectable “pull-ups” if required by BAS.
Selection enables a change in output level
during periods of occupancy.
Low = Occupied
Supply Voltage = Unoccupied
Slide Switch
Note: For High/Low HID lamps or
fluorescent dimming wiring diagrams,
see the Novitas Engineering Manual
or visit http://www.novitas.com.
BI-LEVEL
HID
Coverage Diagram
Novitas, Inc., 370 Amapola Ave., No. 212, Torrance, CA 90501
(310) 218-5360 · FAX (310) 218-5370 · http://www.novitas.com
L1231
MODELS 01-PCI, 01-PCO, 01-PCA, 01-PCS, 02-PCC
DAYLIGHTING SYSTEM
• Photocell sensors for indoor, outdoor, atrium and
skylight applications.
• Selectable time delay.
• Adjustable footcandle calibration.
• Combine with occupancy sensors for added savings.
• Compatible with High/Low HID and fluorescent.
• Optional HID timer.
• Controller powered by a Novitas Switchpack.
• BAS compatible.
• Five-year warranty.
How It Operates:
Daylighting control systems are used to either turn lighting on or
off based upon the amount of natural light detected by the
photocell sensor. Sensors can be used in indoor (01-PCI),
outdoor (01-PCO), atrium (01-PCA) and skylight (01-PCS) applications and for single or multiple load areas.
Photocell sensors use a lens to gather light energy from various
parts of the monitored area and send this information as a signal
to a Controller device (02-PCC). The Controller compares the light
level signal to a preset threshold and activates a Novitas ®
Switchpack to turn loads on if lighting is insufficient. If lighting is
sufficient, the Controller will not activate the Switchpack.
The preset threshold is calibrated at the control board upon installation. A low setpoint and high setpoint are established and
separated by a “deadband” to avoid intermittent or false activation.
When daylighting controls are used in combination with Novitas
occupancy sensors, occupancy/vacancy determines whether the load
is activated or deactivated. When the photocell sensor sends an
insufficient light signal to the Controller, the lighting will be turned on
upon occupancy of the monitored area. If the ambient light level
increases above the preset threshold while the room is occupied, the
lighting will be deactivated. When no motion is detected by the
occupancy sensor and the time delay elapses, the lights will be deactivated regardless of the light level sensed by the photocell.
Patent No. RE 32,450; 5,055,669; 5,039,850
Mounting:
• The indoor sensor (01-PCI) requires a 3/8” penetration hole
and is secured with double-sided adhesive foam (provided) to
the ceiling facing down onto the work surface.
• The outdoor sensor (01-PCO) mounts horizontally facing
north to a standard threaded 1/2” conduit or fits a 1/2”
knockout.
• The atrium sensor (01-PCA) mounts horizontally to a standard
threaded 1/2” conduit or fits a 1/2” knockout.
• The skylight sensor (01-PCS) mounts to a standard threaded
1/2” conduit or fits a 1/2” knockout pointing upward.
• The Controller (02-PCC) can be mounted above the ceiling or
on the wall to a standard NEMA 2S junction box or mounted
on the surface. Secured with double-sided adhesive foam
(provided).
Wiring:
Sensors are provided with insulated pigtails. Sensors and
Switchpacks are interconnected by 18 AWG Class 2 wiring per
NEC 725. Use UL-recognized Teflon-insulated wire approved for
plenum areas per NEC 725-2 (b) where required.
Power Requirements:
Controller is powered by 15 VDC from a Novitas Switchpack only.
• Photocell sensors are connected to Controllers in a 1:1 ratio.
• Up to two Controllers may be powered from one Switchpack.
Output:
Special Features:
• Light measurement setpoints remain constant due to precision
calibration and deadband.
• 30-second time delay available in Controller to prevent false
activation/deactivation from brief changes in natural light.
• Compatible with incandescent, fluorescent and High/Low HID
lighting.
• A flat Fresnel lens on the indoor model avoids false triggers due
to changes in reflected light outside 60 degree field of view.
• Form C relay available for connection to a Building Automation
System (BAS).
• Optional “Hold On” timer ensures sufficient HID lamp warm-up
with an automatic 30-minute run time.
• Manual bypass allows the load to be turned on quickly and easily
should the Controller ever fail.
Up to 10 Novitas Switchpacks may be connected to one
Controller with 20 amps maximum per Switchpack.
Housing:
The outdoor sensor circuitry is protected by a clear epoxy resin
making it waterproof. A visor shields its lens from the natural
elements and its housing is UV stabilized for long life. Plastic
enclosure of the Controller meets flame-retardant requirements
of UL 94V0. LEDs indicate High/Low setpoints and Circuit
On/Off.
Size & Weight:
01-PCI: Length 1.15”; Diameter 2”; Lens diameter 1.28”; 1 oz.
01-PCO: Length 1.35”; Lens diameter 1.48”; 1 oz.
01-PCA and 01-PCS: Length 2.25”; Lens diameter 1.28”; 1 oz.
02-PCC: 4.75”x1.5”x2.5” HDW. Approximately 5 oz.
Range & Coverage:
Installation Considerations:
The indoor sensor (01-PCI) looks downward into the work area
with a 60 degree field of view. Its range is between 6 and 50
footcandles (FC). The outdoor sensor points horizontally, typically
to the north, and has a range between 2 and 40 FC. The atrium
sensor points horizontally and ranges from 40 to 750 FC. The
skylight sensor points upward and ranges from 400 to 3,000 FC.
Both atrium and skylight sensors have 180 degree field of view.
The Sensor must have a clear view of the work surface to be
controlled. Place 6 to 8 feet from windows. Avoid pointing down
onto dark furnishings or carpet. Use where temperatures are
between -11°C (13°F) and 60°C (140°F). Note: The life of some
compact fluorescent lamps (CFLs) is shortened by frequent
automatic or manual switching. Check with CFL and ballast
manufacturer to determine effects of cycling.
c Novitas, Inc. 1998, 1999, 2000, 2002. All rights reserved.
MODELS 01-PCI, 01-PCO, 01-PCA, 01-PCS, 02-PCC
Wiring Diagram
Sensor Table
Sensors
01-PCI
01-PCO
01-PCA
01-PCS
Application
Indoor
Outdoor
Atrium
Skylight
FC Range
6 - 50 FC
2 - 40 FC
40 - 750 FC
400 - 3,000 FC
Lens
Flat Fresnel
Clear Flat
Opaque Dome
Dark Dome
Novitas, Inc., 370 Amapola Ave., No. 212, Torrance, CA 90501
(310) 218-5360 · FAX (310) 218-5370 · http://www.novitas.com
Orientation
Downward
Horizontal
Horizontal
Upward
L1229
ICN4S5490C2LS@120
Brand Name
Ballast Type
Starting Method
Lamp Connection
Input Voltage
Input Frequency
Status
Electrical Specifications
Lamp Type
Num. of
Lamps
* F54T5/HO
F54T5/HO
F54T5/HO
F54T5/HO
F58T8
F58T8
F58T8
F58T8
FT36W/2G11
FT36W/2G11
Rated
Min. Start
Lamp Watts Temp (°F/C)
1
2
3
4
1
2
3
4
1
2
54
54
54
54
58
58
58
58
36
36
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
Wiring Diagram
Input
Current
(Amps)
0.52
0.99
1.52
2.00
0.49
0.92
1.43
1.88
0.39
0.74
Input
Ballast
Power
Factor
(ANSI Watts)
62
0.99
118
0.99
182
1.00
240
1.00
58
0.99
110
0.99
171
1.00
225
1.00
46
1.20
88
1.20
MAX
THD
%
15
10
10
10
15
10
10
10
20
20
CENTIUM
Electronic
Programmed Start
Series/Parallel
120
50/60 HZ
Active
Power
Factor
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.97
0.95
MAX Lamp
B.E.F.
Current
Crest Factor
1.7
1.60
1.7
0.84
1.7
0.55
1.7
0.42
1.7
1.71
1.7
0.90
1.7
0.58
1.7
0.44
1.7
2.61
1.7
1.36
1-10 Continued...
Enclosure
4-lamp
3-lamp
3-lamp
The wiring diagram that appears above is for
the lamp type denoted by the asterisk (*)
Standard Lead Length (inches)
Black
White
Blue
Red
Yellow
Gray
Violet
in.
0
0
0
0
0
0
0
cm.
0
0
0
0
0
0
0
Yellow/Blue
Blue/White
Brown
Orange
Orange/Black
Black/White
Red/White
in.
0
0
0
0
0
0
0
cm.
0
0
0
0
0
0
0
Revised 07/23/2003
Data is based upon tests performed by Advance Transformer in a controlled environment and representative of relative performance. Actual performance
can vary depending on operating conditions. Specifications are subject to change without notice. All specifications are nominal unless otherwise noted.
ADVANCE TRANSFORMER CO.
O'HARE INTERNATIONAL CENTER · 10275 WEST HIGGINS ROAD · ROSEMONT, IL 60018
Customer Support/Technical Service: Phone: 800-372-3331 · Fax: 630-307-3071
Corporate Offices: Phone: 800-322-2086
Lighting the Ceiling
Style 305
1:8 Scale
2-5/8"
(67mm)
A
B
C
D
A
G
E
F
J
F
K
5-5/8"
(143mm)
Length (see chart)
Cove
Cove Dimensions
(Max. candlepower aimed 15° above horiz.)
Sightline Angle
(see chart)
Setback
(see
chart)
1-1/8"
(29mm)
Style 305
T5 Fluorescent
Xtra small concealed, integral
Sightline
Width
(inside)
Lip
(inside)
Setback
(varies)
Maximum
Candlepower
(adjustable)
Width
(see chart)
Lip Height
(see chart)
0°(horiz.
5°
10°
cutoff)
6-1/2"
5-7/8"
5-7/8"
(165mm) (150mm) (150mm)
Lamp
Length
1 x 2'
1 x 3'
1 x 4'
1 x 5'
2 x 3'
2 x 4'
2 x 5'
Luminaire
Length
23-1/16" (586mm)
34-7/8" (886mm)
46-11/16" (1186mm)
58-1/2" (1486mm)
69-1/2" (1765mm)
93-1/8" (2365mm)
116-5/8" (2963mm)
Joint
1:4 Scale
(Ballast compartment
not shown for clarity.)
G
2-5/8"
2-1/8"
1-5/8"
(67mm) (54mm) (41mm)
Recommended minimum:
12" T5, 18" T5HO
H
C
J
Note: Finish interior of cove matte white
for best results.
Specifications
A Specular extruded
aluminum reflector
B Stainless steel lampholder/support brackets
C Aluminum sidearm with
mounting tab
Features
D Extruded aluminum
ballast/wireway
channel cover
E Conduit entry (one
each end, conduit and
connector by others)
Extruded aluminum
ballast/wireway
compartment
G Rotation locking screw
H Joiner/alignment screw
F
Mounting tab (fastener
by others)
K Integral electronic
ballast
J
■ T5 fluorescent - precise optical control for unequaled
projection of light from perimeter coves
■ Adjustable - all reflectors in a row join and aim together;
rotation locking screws secure position*
■ Only 2-5/8" high - fits in low profile coves
■ Integral electronic ballast, thru wiring for easy installation
Performance
Finish:
Reflector - extruded high purity aluminum with clear anodized
specular finish. Sidearms and ballast/ wireway compartment mill finish aluminum. All luminaire hardware - stainless steel.
Mounting:
Lay-in installation requires only one fastener per joint (by
others). Sidearms with mounting tabs can be base or wall
mounted. Luminaires can be mounted individually or joined
together to form a continuous row.
Reflector aiming is adjustable and is fixed in position by
rotation locking screws at each sidearm. When mounted in a
continuous row, joiner screws lock reflectors together allowing
all in the row to be aimed together.
Standard:
UL listed or CSA certified for damp locations.
(Style 151 smooth painted model with gasketed lens
recommended for damp location use; see Outdoor Section.)
Electrical:
Use 90°C wire for supply connections.
Integral electronic HPF thermally protected class P ballast
with end-of-life protection. Ballast/wireway compartment
includes one conduit entry at each end. Channel cover
removes for access to ballast and wiring. Luminaires may be
butted end-to-end (connectors by others) for through wiring.
Master/satellite combination is available (Configuration 3, see
ordering information). Master supplied with 2-lamp ballast.
(Wiring, conduit and connectors between master and satellite
units by others.)
Optional electronic dimming ballast dims to 1% of full light
output. Compatible dimming control is required (by others).
Consult sales representative for specifications.
Optional integral emergency battery operates one lamp.
Separate unswitched supply is required.
For complete ballast specifications, see Accessories Section.
Two parabolic reflector
sections drive light
across the ceiling from
one edge. An elliptical
section shields the lamp
from normal viewing
angles and redirects its
light to a parabola.
Glare is minimized and
asymmetry of the beam
is maximized resulting
in high beam efficiency
and superior surface
uniformity.
1x55W
T5 HO
1x28W
T5
1700
Cd
For complete photometrics, see Indoor Applications Section.
REV. 10/00
*U.S. Patent No. 5,550,725 and foreign.
elliptipar
C
12.4
Style 305
To Order
Project:
To form a Catalog Number
F 3 0 5 -T
1
2
-S -0 0 3
4
5
6
Type:
4 Mounting
7
8
S = Sidearms with mounting tabs for base or wall mounting
1 Source
5 Finish
F = Linear fluorescent
00 = Bright anodized reflector with mill finish ballast
compartment
2 Style
305 = Xtra small concealed, integral ballast
6 Voltage/Ballast
3 Lamp
Electronic
1 = 120V
2 = 277V
Note: To order by overall row length, enter ROW CODE in
place of Lamp Code below (see Row Charts on page
C-12.6). Row Code specifies a row complete with all
necessary reflectors, brackets and ballasts.
* Dimming available for 4' F55T5HO (lamp codes T155 and T255).
For other T5HO lamp lengths or for T5 standard lamps, consult sales
representative. Dimming not available for Reflector Configuration 3.
= Lamp Code (to specify individual units)
T
Lamp Wattage (see chart below)
Reflector Configuration, specify 1, 2 or 3
(see chart below)
Example: T228 = two 28W T5 lamps in nominal 8' reflector;
one 2-lamp ballast
Reflector Configuration
1 - Lamp Ballast
1
2-Lamp Reflector
Example
2 - Lamp Ballast
3
Lamp Wattage
T5 Fluorescent
14
21
28
35
T5 HO Fluorescent *
24
39
55
80
00 = No options
0E = Integral emergency battery pack with indicator lamp
and test button. Operates one lamp. Available in
nominal 4', 6' and 8' units only (lamp codes T128,
T221, T228, T328, T155, T239, T255 and T355).
XX = For modification not listed, include detailed
description. Consult factory prior to specification.
0 = UL, Underwriters Laboratories
J = CSA, Canadian Standards Association
2
1-Lamp Reflector (Master)
7 Option (See Accessories Section for specifications)
8 Standard
1-Lamp Reflector
2 - Lamp Ballast
C
12.5
Dimming *
T = 120V
V = 277V
1-Lamp Reflector (Satellite)
Lamp Length
Lamp Number
2'
3'
4'
5'
F14T5
F21T5
F28T5
F35T5
2'
3'
4'
5'
F24T5/HO
F39T5/HO
F55T5/HO
F80T5/HO
F305 - T221 - S - 00 - 1 - 000
Xtra small concealed fluorescent unit consisting of one
nominal 6' reflector with two 21W T5 lamps. Integral 120V
electronic 2-lamp ballast. Sidearms with mounting tabs. UL.
For complete lamp and ballast information, see Accessories Section.
Standard T5 and T5HO lamp color is 3000K / 80+ CRI.
REV. 12/02
elliptipar
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
n
n
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. © 2002 elliptipar.
Lighting the Ceiling
Xtra small concealed, integral
Style 305
T5 Fluorescent
Time saving - simplifies specification and ordering
One catalog number - includes all necessary reflectors
to install row
■ Assured fit - all you need is the clear inside length of
the cove
■
■
REV 12/02
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
1
1
1
1
1
3
1
1
1
1
1
2
1
1
1
2
1
1
1
1
1
1
1
1
1
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
A
B
C
A
D
B
F
A
G
C
D
D
F
A
B
D
F
G
D
F
G
A
C
D
B
F
D
F
G
A
D
F
G
D
F
G
Nominal 4' Luminaire
(1 x nominal 4' lamp)
3
4
5
6
7
8
8
9
9
10
10
11
11
12
12
13
13
13
14
14
14
15
15
15
16
16
17
17
17
18
18
18
18
19
19
19
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Lamp
Combination
3 Row Code
When the Style 305 xtra small concealed T5 fluorescent is run
continuously in straight coves, elliptipar offers the option of
Note: Enter row code in place of Lamp Code described on
specifying and ordering the entire row as one catalog number.
page C-12.5.
Ordering by row eliminates the need to calculate length, type
and quantity of reflectors.
= Row Code
Steps to specify Row Code:
Lamp Combination*
1. Determine clear inside length of cove.
A = All nominal 3' lamps
B = All nominal 4' lamps
2. Round up to nearest foot and find the nominal row length
in chart.
C = All nominal 5' lamps
D = Nominal 3' and 4' lamps
3. Determine what lengths/wattages of lamps will be used and
F = Nominal 3' and 5' lamps
select the corresponding lamp combination codes.
G = Nominal 4' and 5' lamps
Example: If only 3' and 4' lamps are to be used on the
project, specify row codes ending with A, B and/or D only.
Nominal Row Length in feet, between 3' and 50' **
4. If for a given nominal row length a preferred lamp
S = T5 fluorescent
combination is not listed, select the next shorter row that is
V = T5/HO fluorescent
available in the desired lamp combination.
* Not all lamp combinations are available for each nominal row length
5. Once the nominal row length and lamp combination has
(see chart)
been found in the chart, note the actual overall row length
** Nominal row lengths over 50' can be formed by combining shorter
(last column).
row lengths. (Example: a nominal 60' row can be ordered as two
6. Consider the unlighted length at each end of the row.
nominal 30' rows.)
(Subtract the overall row length from the clear inside length,
and divide the remainder by two.) It is generally
Example
recommended that the unlighted length at each end be
between 6" and 12".
F305 - S15A - S - 00 - 2 - 000
7. Enter the four character Row Code in place of the Lamp
Code described on page C-12.5. The remainder of the
Nominal 15' long row of Style 305 xtra small concealed T5
catalog number is formed as shown on page C-12.5.
fluorescent using only nominal 3' (21W) lamps. Row includes
two nominal 6' luminaires for use with two 3' lamps each, one
nominal 3' luminaire for use with one 3' lamp and integral
277V electronic ballasts. Overall row length is 14' 5-7/8".
Features
Nominal Row
Length (feet)
To order by Row Code
2' 10-7/8"
3' 10-11/16"
4' 10-1/2"
5' 9-1/2"
6' 9-9/16"
7' 9-1/8"
7' 9-3/8"
8' 8-3/8"
8' 9-3/16"
9' 8-5/8"
9' 8-3/16"
10' 8"
10' 8"
11' 7"
11' 7-13/16"
12' 7-1/16"
12' 7-1/2"
12' 7-5/8"
13' 6-5/8"
13' 6-7/8"
13' 7-5/16"
14' 5-7/8"
14' 7-1/8"
14' 6-11/16"
15' 6-1/4"
15' 6-1/8"
16' 5-1/2"
16' 5-1/2"
16' 6-5/16"
17' 4-1/2"
17' 5-5/16"
17' 6"
17' 5-3/4"
18' 5-1/8"
18' 5"
18' 5-13/16"
elliptipar
C
12.6
Style 305
T5 Fluorescent
Xtra small concealed
REV. 3/02
1
1
1
1
1
1
1
2
3
2
1
1
1
2
1
1
1
1
2
1
4
3
1
1
1
1
2
2
1
1
1
1
1
1
1
2
2
2
1
1
4
3
1
1
1
1
1
2
1
1
1
2
1
3
1
1
1
1
1
1
2
1
1
2
2
2
2
1
5
3
1
3
elliptipar
3
2
1
5
1
1
2
1
1
4
3
1
3
1
1
1
1
1
1
2
1
1
4
1
3
2
2
3
2
2
1
6
1
4
1
1
1
3
1
3
4
4
1
1
3
1
1
1
2
3
6
1
1
4
1
3
5
4
1
1
1
1
1
1
4
2
7
1
2
3
2
4
1
1
3
3
30'
30'
30'
31'
31'
31'
31'
31'
32'
32'
32'
33'
33'
33'
34'
34'
34'
35'
35'
36'
36'
36'
37'
37'
37'
38'
38'
39'
39'
39'
40'
40'
40'
40'
0-15/16"
1-1/4"
1-3/8"
10-3/8"
0-1/2"
11-3/4"
0-1/4"
1-1/16"
11-9/16"
0-3/4"
0-7/8"
11-3/8"
0-1/8"
0"
9"
11-3/16"
0-3/8"
10-7/16"
11"
10"
9-3/4"
11"
7-7/8"
10-1/16"
11-1/16"
9-5/8"
10-1/2"
8-7/8"
9-7/8"
10"
6-1/2"
8-11/16"
8-7/8"
9-11/16"
elliptipar
114 Orange Avenue, West Haven, Connecticut 06516, USA
Voice 203.931.4455 Fax 203.931.4464 www.elliptipar.com
n
n
1
1
5
1
1
1
3
5
4
1
7
1
1
4
1
2
4
1
1
1
4
1
1
1
2
5
1
1
4
5
1
1
2
1
4
3
3
3
8
6
1
1
1
1
1
1
1
1
5
4
4
5
1
3
8
1
1
4
4
4
6
1
1
1
2
4
3
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
D
F
G
B
F
G
A
C
D
D
F
G
D
F
G
A
B
F
G
D
F
G
C
D
A
D
F
G
Nominal 5' Luminaire
(1 x nominal 5' lamp)
42
42
42
43
43
43
44
44
44
45
45
45
46
46
46
47
47
47
47
48
48
48
49
49
50
50
50
50
Nominal 4' Luminaire
(1 x nominal 4' lamp)
1
Nominal 3' Luminaire
(1 x nominal 3' lamp)
1
1
Overall
Row
Length
1
Nominal 10' Luminaire
(2 x nominal 5' lamps)
Nominal 4' Luminaire
(1 x nominal 4' lamp)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 3' Luminaire
(1 x nominal 3' lamp)
D
F
G
A
B
D
F
G
D
F
G
D
F
G
A
B
C
D
G
D
F
G
A
D
G
B
C
D
F
G
A
D
F
G
Nominal 6' Luminaire
(2 x nominal 3' lamps)
3
1
1
31
31
31
32
32
32
32
32
33
33
33
34
34
34
35
35
35
36
36
37
37
37
38
38
38
39
39
40
40
40
41
41
41
41
Lamp
Combination
1
4-15/16"
5-1/4"
3-3/8"
4-3/16"
4-5/8"
4-3/4"
3-3/16"
3-5/8"
4-7/16"
3-13/16"
4-1/8"
4-1/4"
2"
3-3/8"
3-1/2"
3-15/16"
3-3/4"
2-5/8"
2-7/16"
2-3/4"
2-7/8"
0-7/8"
2-1/4"
2-1/8"
2-15/16"
2-1/16"
2-5/8"
2-3/8"
1-5/16"
1-5/8"
2-7/16"
11-1/2"
1-7/8"
0-7/8"
Nominal 5' Luminaire
(1 x nominal 5' lamp)
1
1
19'
19'
20'
20'
20'
20'
21'
21'
21'
22'
22'
22'
23'
23'
23'
23'
24'
24'
25'
25'
25'
26'
26'
26'
26'
27'
27'
27'
28'
28'
28'
28'
29'
29'
Lamp
Combination
2
Overall
Row
Length
Nominal 10' Luminaire
(2 x nominal 5' lamps)
2
Type:
Nominal Row
Length (feet)
1
Nominal 8' Luminaire
(2 x nominal 4' lamps)
Nominal 6' Luminaire
(2 x nominal 3' lamps)
Nominal 5' Luminaire
(1 x nominal 5' lamp)
B
C
A
D
F
G
D
F
G
D
F
G
A
B
F
G
C
D
D
F
G
A
D
F
G
B
F
G
D
F
G
A
C
D
Nominal 4' Luminaire
(1 x nominal 4' lamp)
20
20
21
21
21
21
22
22
22
23
23
23
24
24
24
24
25
25
26
26
26
27
27
27
27
28
28
28
29
29
29
30
30
30
Nominal 3' Luminaire
(1 x nominal 3' lamp)
Lamp
Combination
C
12.7
Nominal Row
Length (feet)
Project:
Nominal Row
Length (feet)
Lighting the Ceiling
41'
41'
41'
42'
42'
42'
43'
43'
43'
44'
44'
44'
45'
45'
45'
46'
46'
46'
46'
47'
47'
47'
48'
48'
49'
49'
49'
49'
8-1/2"
9-3/8"
9-3/16"
8-5/16"
7-1/4"
9-3/16"
5-3/8"
9"
7-9/16"
7-1/8"
8"
8-1/8"
7-3/16"
7-3/8"
8-3/16"
4"
6-3/4"
7-7/8"
7-5/8"
6"
6-7/8"
7-11/16"
7-1/8"
5"
2-7/8"
5-5/8"
6-1/2"
6-5/8"
The external shapes of the asymmetric reflectors are trademarks of elliptipar.
Certain products illustrated may be covered by applicable patents and patents pending.
For a list of patents, see Contents pages. These specifications supersede all prior
publications and are subject to change without notice. © 2002 elliptipar.
E
Lightcast Double washlight
for low-voltage halogen lamps
157
20
∅ 157
∅ 170
Size 5
40°
QT12-ax
7z
22457.000
Reflector colour Silver
QT12-ax 100W 12V GY6,35 2200lm
Product description
Lampholder carrier: cast aluminium, black powder-coated, designed
as heat sink.
Mounting ring: cast aluminium,
white (RAL9002) powder-coated.
Tools not required for mounting
with 4-point support and screw
fixing.
Cable, L 500mm.
Darklight reflector: aluminium,
bright anodised. Cut-off angle 40°.
Diffuser as lamp cover: glass,
frosted.
Transformer according to EN
61558 or EN 61347 to be ordered
separately.
Weight: 0.70 kg
ERCO Leuchten GmbH
Postfach 24 60
58505 Lüdenscheid
Deutschland
Tel.: +49 2351 551-0
Fax: +49 2351 551-300
info@erco.com
Mean illuminances Em (lx)
Specifications:
Number of luminaires n > 5
Light loss factor 1,25
without indirect component
without peripheral area
QT12-ax 100W 12V GY6,35 2200lm
Wall height (m) 3,00
Offset from wall (m)
Luminaire spacing (m)
0.60
0.60
0.90
0.90
0.90
1.20
1.20
1.20
Illuminance (lx)
227
112
84
60
Technical Region: 230V/50Hz
Edition: 03.03.2004
Please download the current version
from
www.erco.com/22457.000
1/3
Lightcast Double washlight
E
42
32
ta 50° C
215
42
83582.000
Concrete housing
Metal, powder-coated.
L 440mm, W 300mm.
Recessed depth 170mm.
Ceiling aperture ø 157mm.
115
270
295
CO 157
170
300
440
83951.000
Plaster ring
Metal, white.
Height 20mm.
1150
83833.000
Electronic transformer EN 61347
230/12V, 20-105W at max. 50°C
ambient temperature, controllable
1V-10V.
Secondary voltage 11.7V.
Installation in ceiling voids, showcases, furniture.
Plastic housing. Primary and secondary cable clamps and terminal
blocks.
Short-circuit protection: electronic
cut-out, reconnection once shortcircuit is cleared.
Overload and overheat protection:
automatic load-sensing.
Use dimmers for electronic transformers (trailing edge).
For interference suppression to
VDE 0875, part 2, secondary cable
length max. 2m.
For ceiling aperture ø 58mm,
recessed depth 180mm
IP rating II.
L 215mm, B 42mm, H 32mm.
Weight 0.20kg.
i ta 50° C
83819.000
Overvoltage protection device
For max. 10 electronic transformers.
L 45mm, B 25mm, H 22mm.
2x1.5mm², L 80mm.
Weight 0.05kg.
Only in conjunction with:
83831.000
83833.000
83774.000
Mounting ring
Metal, white powder-coated. For
flush-mounting installation in
plasterboard ceilings.
Diameter 170mm.
Ceiling aperture ø 174mm.
12,5–20,0
152
83831.000
Electronic transformer EN 61347
230/12V, 50Hz. 20-105W at max.
50°C ambient temperature.
Secondary voltage 11.8V.
Installation in ceiling voids, showcases, furniture.
Plastic housing. Primary and secondary cable clamps and terminal
blocks.
Short-circuit protection: electronic
cut-out, reconnection once shortcircuit is cleared.
Overload and overheat protection:
automatic load-sensing.
Use dimmers for electronic transformers (trailing edge).
For interference suppression to
VDE 0875, part 2, secondary cable
length max. 2m.
For ceiling aperture ø 58mm,
recessed depth 110mm
MM sign.
ENEC10 sign, VDE sign.
IP rating II.
SELV sign.
L 152mm, B 42mm, H 32mm.
Weight 0.19kg.
0 q i S t V SELV MM
18
32
Accessories
∅ 170
CO ∅ 174
82950.000
Mounting plate for panelled
ceilings
Metal, white (RAL9002) powdercoated. Individual design of
mounting plates according to
ceiling type and luminaire. Quote
ceiling type and dimensions.
Lightcast Double washlight
22457.000
2/3
E
Lightcast Double washlight
Accessories
83980.000
Cover ring
Metal, white. For covering the gap
where ceiling cut-outs are too big.
Inner and outer diameter to be
specified when placing order.
Lightcast Double washlight
22457.000
3/3
A total of 20 set points are provided allowing up to 140 operations
each week (20 set points X 7 days = 140 operations ). Repeat this
procedure for as many of the 20 set points as required. Attempts
to enter additional set points (beyond 20) will cause “F:UL” to
appear in the display.
TO OVERRIDE PROGRAM: Program can be overridden at any
time by selecting the MANUAL position. Program set points will be
maintained but will not operate the controlled load(s)
automatically.
TO REVIEW PROGRAM SET POINTS: Place the three position
selector in the PROGRAM mode. Place the two position selector
in OUTPUT mode. The display will show all zeros if there are no
set points programmed or will show the first programmed set
point and a programmed time with an ON or OFF depending on
whether the time which appears is an ON set point or an OFF set
point. Pressing the ENTER button will advance the display to the
next set point in chronological order. In other words, the next set
point on Sunday or the set point on Monday (day 2) will appear.
Pressing the ENTER button after the last set point has been
displayed will cause ‘E:nd” to appear in the display. Further
operation of the ENTER button will repeat the review cycle.
TO ADD OR DELETE SET POINTS: Press the HOUR and/or
MINUTE buttons to change the time displayed to show the new
time you wish to add, then press the ENTER pushbutton. To
remove a programmed time, press the ON/OFF button two
times. when this is done, the set point displayed will be removed
and the display will show all dashes.
To Operate Timer
After programming is complete, move the selector switches to
the CLK and AUTO positions. The time switch will follow the
scheduled program but will not immediately “catch up” to the
presently programmed load condition; the time switch will “catch
up” at the next scheduled ON or OFF setpoint. If necessary,
press the ON/OFF button to turn the load on or off.
Trouble Shooting
SYMPTOM
POSSIBLE CAUSE(S)
Battery not properly installed or
defective.
Check battery and replace if necessary.
Display shows scrambled or
erratic times.
Time switch has not been reset.
Press the recessed reset switch and hold for
approximately 5 seconds.
Electrical noise interference is highly unlikely
since the electronic circuitry and the power
supply are completely isolated. The installation
of surge suppressors (metal oxide varistorsMOVS) across terminals 3/4 (model ET173C
and ET174C across terminals 3/4 & 5/6) will help
to reduce electrical noise generated at the
switching contacts.
Electrical noise is interfering with the
operation of the microprocessor.
Display shows “L-bA”.
Display means “Low Battery”.
Display shows “Err 1” message.Slide switch not fully in its detent
position (open circuit).
Display shows “Err 2” message.
Display shows “Err 3” message.
Load does not switch atprogrammed time.
PROGRAM/MANUAL/AUTO selector
not in AUTO position.
Time switch is programmed incorrectly.
Power has not been supplied to the
load. Note that the Neutral and Line
terminals #1 & 2 (Line 1 and Line 2
are terminals for model ET174C) are
isolated from the output terminals.
With Battery Carryover
ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR INTERMATIC
TIME SWITCH. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE! RETAIN FOR FUTURE REFERENCE.
Specifications
AM
ON
5:20
Be sure MANUAL./AUTO is in the AUTO
position.
Check program - place the Program Selector in
the PROGRAM mode and press the Enter button
to review all twenty.
Be sure power is applied to the line terminals #3
(#3 and #5 for ET173C and ET174C) in order to
power the load. Note that the output contacts are
isolated from the timer power (terminals 1
and 2). This allows the timer to switch various
loads from 24 volts through 277 volts.
SPRING GROVE, ILLINOIS 60081-9698
CLOCK VOLTAGE: 120 V.A.C., 60 Hz. (ET171, ET173C, &
ET175C)
240 V.A.C., 60 Hz. (ET174C)
POWER CONSUMPTION: 3.0 Watts Max. (ET171C &ET175C)
5.0 Watts Max. (ET173C & ET174C)
CONTACT CONFIGURATION: SPST model ET171C
DPST model ET173C & ET174C & SPDT model ET175C
SWITCH RATING: (Per Pole for ET173C & ET174C)
• 30 Amps Inductive/Resistive, 24/120/240 V.A.C., 60 Hz.
• 20 Amps Resistive - 28 V.D.C.,
• 1 H.P. 120 V.A.C., 60 Hz.
• 2 H.P. 240 V.A.C., 60 Hz.
• 5 Amps Tungsten, 120/240 V.A.C., 60 Hz.
• 20 Amps Ballast 277 V.A.C., 60 Hz.
SWITCH RATINGS: ET175C
N.O.
N.C. CONTACT
20 AMP
10 AMP
Resistive and
General Purpose
1 H.P.
1/4 H.P.
MOTOR
2 H.P.
1/2 H.P.
MOTOR
5 Amp
TUNGSTEN
20 Amp
3 Amp
BALLAST
Reposition slide switch into detent or “wiggle” until
display is corrected. If display does not correct,
contact or return to factory for service.
Slide switch shorted circuit.
Slide switch illegal position.
INTERMATIC INCORPORATED
INCLUDING MODELS:
ET171C (SPST) 120V Supply
ET173C (DPST) 120V Supply
ET174C (DPST) 240V Supply
ET175C (SPDT) 120V Supply
OWNER/INSTALLER INSTRUCTION MANUAL
Replace battery within 30 days.
LIMITED ONE YEAR WARRANTY
If within one (1) year from date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace, at its sole option,
the unit free of charge. This warranty applies only to the original purchaser and is not transferable.
The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to
unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with directions; (d) damages exceeding the cost of the product. Some
states do not allow a limitation of damages, so the foregoing limitation may not apply to you.
This warranty gives you specific legal rights and you may have other rights that vary from state to state.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER
EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS
FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME
DURATION AS THE WARRANTY PERIOD STATED ABOVE.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing postage prepaid to the nearest
authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by: Intermatic
Incorporated,/After Sales Service/ 7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-7000 http://www.intermatic.com
158ET10371
Electronic 7 - Day Time Switches
CORRECTIVE ACTION
Time switch has no display.
ET170 SERIES
®
Description
The Intermatic Electronic 7-Day Time Switch automatically
switches loads according to a preset weekly schedule with to-theminute accuracy. This time switch is designed to directly switch
inductive or resistive loads up to 30 amps at 24, 120 or 240 volts
and to switch tungsten or ballast loads up to the time switch rating.
For use as a control timer in applications requiring 7-day load
control such as lighting, heating, air conditioning systems, pumps,
etcetera. Up to 20 (10 ON/10 OFF or any combination) set points
(EVENTS) can be preset. These set points can be programmed for
any or all 7 days to provide for up to 140 set points each week.
Independent 7 day programming provides complete flexibility for
applications where load switching differs each day of the week.
The program can be overridden by selecting the MANUAL position.
28 VDC.
120-240 VAC
120 V.A.C.
240 V.A.C.
120-240 V.A.C.
120-277 V.A.C.
SET POINTS (EVENTS): 20 total (10 ON/10 OFF or any
combination) daily.
Up to 140 (70 ON/70 OFF or any combination) weekly.
BATTERY POWERED CLOCK OPERATION: 3 Years minimum
(AA industrial grade alkaline supplied with time switch)
MIN. “ON” or “OFF” TIME: 1 minute.
MAX. “ON” or “OFF” TIME: 6 days 23 hours 59 minutes.
SHIPPING WEIGHT: 2.5 Lbs. (1.1 Kg)
CASE: Drawn steel; 7-3/4” (19.7 cm) high, 5” (12.7 cm)
wide, 3” (7.6 cm) deep; gray finish w/lockable spring hasp.
KNOCKOUTS: Combination 1/2 - 3/4” (one on back and
each side, two on bottom).
WIRE SIZE: AWG #10 through #18.
General Safety Information
WARNING: Disconnect all power before installing or servicing this time
switch or its connected loads.
1. Follow all local electrical and safety codes, National Electric Code
(NEC), as well as Occupational Safety and Health Act (OSHA).
2. If the power disconnect point is out of sight, lock it in the “OFF”
position and tag it to prevent unexpected application of power.
3. This time switch case must be grounded.
4. Do not exceed the maximum current carrying capacity of this
time switch.
5. Always replace the plastic insulator covering the terminal before
turning power “ON”.
Installation
DAY
WARNING: DISCONNECT THE POWER TO THE TIME
SWITCH AND THE LOADS BEFORE INSTALLING THIS TIME
SWITCH.
1. Mount the time switch in the desired location using the
three mounting holes which are provided. Mount the
time switch at eye level, if possible, providing sufficient
room to the left of the enclosure for the cover to swing open
fully. (See Figure #1 and Figure #2). The time switch
mechanism does not need to be removed from the enclosure
to mount the time switch since the top mounting hole is a
slotted type mounting hole. Secure a screw or other fastener
at eye level. The head of the screw or fastener should be
slightly larger than the narrow portion of the slotted hole to
ensure that the time switch is securely held in place. The
remaining two mounting holes are accessible without
removing the time switch mechanism and will provide secure
and permanent mounting of the time switch.
2.If you do remove the mechanism, refer to Figure #1 and
remove the mechanism from the case by depressing
the catch at the top of the case and pulling out.
CAUTION: DO NOT TOUCH THE CIRCUIT BOARD
COMPONENTS SINCE STATIC DISCHARGE COULD
DAMAGE THE MICROPROCESSOR.
3.Replace the mechanism in the case if it has been
removed.
EVENT
MON.
2
TUES.
3
WED.
4
THUR.
5
FRI.
6
SAT.
7
120 or 240 VAC
Input
Install jumper Only If Timer
Input and Load Voltage Are
The Same, Otherwise provide
a separate source of load
power to terminal 3 & 5.
FIG. #4
ET173C DPST
ET174C DPST
Programming Steps
Mounting Holes
Refer to programming instructions in this manual or the abbreviated
instructions on time switch door label and note the following:
6.Replace the plastic insulator.
Knockouts
FIG. #2
NOTE: For 120 Volt loads only since the timer voltage is 120 VAC
a jumper can be added between terminals 2 and 3 to supply load
power.
CAUTION: Do not use jumper if load(s) are not 120V. because the
load can be damaged. Supply separate power of the correct voltage
to terminal 3.
9.Reapply power to the time switch.
10.Press the reset switch for three to five seconds. The
display will now show 12:00 A.M. and day #1. Note that
the days of the week are numbered 1 through 7 for
Sunday through Saturday. The timer is now ready for
programming. Refer to the chart which follows and
enter the scheduled events (set points) required. Assign
each of the 20 set points (EVENTS) entered to
whichever day or days of the week you wish an ON or
OFF operation to occur. simply put a check in the box
that applies. Note that programming two off times in
sequence, allows the user to manually turn a load on,
after normal working hours for example, and allows the
time switch to automatically turn the load back off. This
is an energy saving feature which allows loads to be
manually switched on after normal occupancy times,
but provides for automatic off switching of these loads.
Note that several off times in a row can be programmed
to provide several “auto off” times.
SUN.
1
FIG. #1
5.Strip the supply and load wires by removing 1/2 inch of
insulation. DO NOT USE ALUMINUM WIRE. (See
figures 3, 4 or 5). Insert the wire ends under the proper
terminal plates and tighten the screws firmly. Use AWG
#10 through #18. Connect ground wire to grounding
terminal at bottom of case.
8.Place the selector switches in the AUTO and CLK
position.
“ON” OR “OFF”
OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
4.Lift the left side of the insulator off of the retaining post
and pivot it up and away to expose the terminal strip.
7.Be sure that the battery is functioning properly. This can
be checked by making sure the display is visible. If the
display has scrambled information, press the RESET
switch and hold for three to five seconds. Note that the
battery can easily be replaced without removing the time
switch mechanism or field wiring. Simply press in and down
ward (in the direction of the arrow) on the battery cover which
is identified with the word “Battery”. It is recommended that
the battery be replaced with a “AA” industrial grade alkaline
cell at two to three year intervals as part of the normal
time switch maintenance observing battery polarity
markings when installing. No other maintenance is
required.
SWITCHING
TIMES
Install Jumper Only If
Timer Input and Load
Voltage Are The Same,
Otherwise provide a
separate source of load
power to terminal 3.
FIG. #3
ET171C SPST
• The three position slide switch is used to select automatic operation
(AUTO), manual operation (MANUAL) or to select programming
(PROGRAM). The MANUAL position can be used to temporarily
override the program. Under normal operation, the selector should
be in the AUTO mode. The MANUAL mode maintains the program but
prevents the loads from automatically switching. FOR A PROGRAM
TO SWITCH LOADS AT THE CORRECT TIMES, THE SELECTOR
SWITCH MUST BE IN THE AUTO POSITION.
• The two position selector switch is used to select programming for
the time of day and day of week (CLK) or select programming for the
switching times (OUTPUT).
• The RESET switch is used only prior to programming to reset the
microprocessor or to erase all programmed set points.
• By holding the hour and/or minute buttons depressed, you can
achieve a fast roll of the displayed time. This is useful when setting
the time of day or programming set points (EVENTS).
• UP to 10 ON and 10 OFF set points or any combination up to 20 set
points (EVENTS) can be programmed and can be assigned to any
or all 7 days for up to a maximum of 140 set points each week.
• The load can be manually switched ON or OFF at any time if the
selector switch is in either the MANUAL or AUTO mode by pressing
the ON/OFF button.The two position selector MUST BE IN OUTPUT
MODE.
• Pressing the ON/OFF button two times in the PROGRAM mode
causes the event time displayed to be removed from the program.
(only if the set point event has already been entered). The display
will show “-:--”.
NOTE: For 120 Volt loads only since the timer voltage is 120 VAC
jumpers can be added between terminals 2 and 3 to supply load power.
CAUTION: Do not use jumpers if load(s) are not 120V. because the load can be
damaged. Supply separate power of the correct voltage to terminal 3.
TIMER
POWER
1
NEUTRAL
3
LINE
4
5
LINE 1
Install jumper Only If Timer
LOAD 1
Input and Load Voltage Are
The Same, Otherwise provide
a separate source of load
power to terminal 3.
LOAD 2
For breaking one side of
120 volt loads.
NEUTRAL
NEUTRAL
FIG. #5
ET175C SPDT
LOAD STATUS INDICATOR
“ON” or “OFF”
Programming
RESET TIME SWITCH: Press the recessed RESET switch to reset the
microprocessor and delete any set point information which has been
programmed. NOTE: DO NOT press RESET after programming has
begun or you will loose all of your program information.
TO SET TIME AND DAY OF WEEK: Place the three position selector
in PROGRAM and the two position selector in CLK mode. Press the
HOUR, MINUTE and DAY buttons individually to select the current time
of day (12 hour AM/PM repeating) and the day of the week. Day 1 is
Sunday, day 2 is Monday, etc.
TO PROGRAM SET POINTS: Select PROGRAM mode with the three
position selector and OUTPUT mode with the two position selector.
Press the HOUR and MINUTE buttons separately to program the first
set point time desired. Press the DAY button to select the day the event
is to occur. Press the ON/OFF button to select an ON or OFF set point.
Press the ENTER button to enter that set point for the selected day.
Note that the ON or OFF indicator stops flashing only after pressing
ENTER. If this set point is to occur for other days of the week, simply
press the DAY button to select the next day then ENTER. Repeat for
any additional days. Note that this allows you to utilize one set point for
any or all days of the week.
2
AM ON
DAY
INDICATOR
5:20
PROGRAM OUTPUT
PROGRAM CLOCK
SELECTOR
2 POSITION
PROGRAM
AUTOMATIC
MANUAL
OVERRIDE
SELECTOR
3 POSITION
PROGRAMMING
BUTTONS
PROGRAMMING/
MANUAL LOAD
CONTROL
BUTTON
FIG. #6
Recessed Wall/Wash
G-D-1000
TYPE:
PROJECT:
ASYMMETRIC
RECESSED DIRECT
SPECIFICATIONS
HOUSING. Die-formed and welded 20-gauge steel finished in baked Matte White enamel. Ends are notched to allow
installation in exposed inverted T-bar grid ceiling (NEMA type GF) with main T-bars at 2'-0" OC or 4'-0" OC. Exposed flanges along
the sides of the fixture support the ceiling tiles. The housing ends are provided with 7/8" diameter knockouts (1/2" trade size). The
top of the housing has an access opening covered by a plate containing two 7/8" diameter knockouts.
REFLECTOR. Die-formed .025" thick specular aluminum .
BALLAST. Electronic, high power factor, thermally protected Class P, Sound Rated A, manufactured by a UL Listed
4 3/4"
manufacturer,
as available, determined by Litecontrol. The minimum number of ballasts will be used.
(121)
MOUNTING. The fixture is intended for installation in standard exposed inverted T-bar grid ceiling (NEMA type GF) with main Tbars at 2'-0" OC or 4'-0" OC. Exposed flanges along the side of the fixture support the tiles. T-bar safety clips at the end of the fixture shall be attached at the factory prior to shipping. 1/4" diameter holes have been provided, positioned at 90° to each other,
along the upper edges of the housing for installation of supplementary chain or wire support as may be required by local codes.
Estimated installed weight of 4-foot fixture is 20 lbs. For drywall or plaster ceiling installations, a ceiling trim
conversion kit is available. Consult factory.
CERTIFICATION. Fixture and electrical components shall be UL and/or CUL Listed and shall bear the I.B.E.W., A.F. of L. label.
9 1/16"
(230)
6 3/8"
(162)
10 1/2"
(267)
Note: Litecontrol reserves the right to change specifications without notice for product development and improvement.
U.S. Patent No. D351,039
ORDERING GUIDE
Section
Mounting - Distribution -
Series
Lamp
Count
Nominal
Lamp
Length (ft.) Type
-
Finish -
Ballast
-
Option
-
Volts
Lamps
Length
in. (mm)
G
D
10
1
2
T8
CWM
ELB
1-F17T8
24 (610)
G
D
10
1
4
T8
CWM
ELB
1-F32T8
48 (1219)
G
D
10
2
2
T8
CWM
ELB
2-F17T8
24 (610)
G
D
10
2
4
T8
CWM
ELB
2-F32T8
48 (1219)
G
D
10
1
2
BX
CWM
ELB
1-FT40W
24 (610)
G
D
10
2
4
BX
CWM
ELB
2-FT40W
48 (1219)
G-D-1014T8-CWM-ELB-120 is a typical catalog number for a one-lamp, 4-foot long T8 fixture, painted Matte White, with electronic ballast, 120 volts.
Finish: CWM (Matte White) is standard.
BALLAST OPTIONS
OTHER OPTIONS
Specify in place of ELB, contact factory for availability/compatibility with lamping:
ELB10
Electronic ballast, same specification as above,
except less than 10% THD.
MKV/ELB
Advance Mark V electronic ballast.
DA-ELB
Advance Mark VII dimming ballast.
HEL/ELB
Motorola Helios dimming ballast.
ECO/ELB
Lutron ECO-10 dimming ballast.
EF
100 HAWKS AVENUE
. . . an employee owned company
HANSON
MA
02341
781 294 0100
Emergency fluorescent ballast. Battery-powered ballast from a UL Listed
manufacturer will operate one T8 lamp in a 4' or 8' fixture for 1 1/2 hours.
F
Fuse. Slow or fast blow, determined by Litecontrol.
RF
Radio frequency interference filter. Advance RIF-1,
unless otherwise specified.
T2M, T2S Tandem ballasting. For energy considerations combine T2M
(Master) with T2S (Slave).
T2M - Fixture would contain one two-lamp ballast.
T2S - Fixture would not contain a ballast.
FAX 781 293 2849
info@litecontrol.com
www.litecontrol.com
PHOTOMETRIC DATA
22
2
44
99
360
571
623
636
719
814
964
1140
1294
1358
1222
1042
879
728
562
407
45
2
19
37
64
93
124
157
191
224
258
288
316
341
362
381
395
402
403
407
67
1
5
5
8
9
9
11
12
13
13
17
36
57
52
67
136
217
292
407
90
0
3
5
3
3
2
3
2
4
4
5
6
9
34
43
49
138
251
407
OUTPUT
LUMENS
29
154
296
337
354
345
277
145
ZONE
RCC
RW
70
80
50 30
10
.81
.74
.68
.62
.56
.51
.47
.43
.39
.36
.33
.81
.71
.62
.55
.48
.42
.37
.33
.30
.27
.24
.81
.66
.54
.45
.38
.31
.27
.23
.20
.17
.15
ANGLE
0
1
65
195
497
770
1041
1286
1371
1495
1659
1752
1811
1814
1813
2108
2161
2083
1505
1006
22
3
65
238
492
767
945
1068
1245
1375
1482
1568
1569
1839
2010
2076
2068
1761
1353
1006
45
4
33
66
122
195
274
361
449
536
621
700
772
836
893
941
973
995
1004
1006
67
3
9
12
13
13
17
20
21
22
26
31
57
135
130
199
306
436
661
1006
90
0
7
7
7
7
7
7
7
7
8
8
11
16
57
133
164
318
529
1006
0
1
2
3
4
5
6
7
8
9
10
440
537
587
552
472
314
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
0
4
115
291
507
657
799
812
854
883
943
1063
1192
1310
1430
1285
810
538
356
22
1
13
130
293
451
545
604
667
749
869
1008
1131
1294
1362
1219
869
649
479
356
45
1
19
36
50
65
94
132
169
201
230
258
284
305
325
340
352
358
357
356
67
2
6
9
10
13
14
15
18
20
19
22
25
45
90
139
202
252
300
356
90
1
3
3
1
1
1
1
1
5
4
5
6
7
16
66
125
213
279
356
RCC
RW
250
304
331
328
274
151
.76
.67
.58
.52
.46
.40
.35
.32
.28
.25
.23
.76
.65
.55
.47
.41
.35
.30
.26
.23
.20
.18
.76
.63
.52
.44
.37
.31
.26
.23
.19
.17
.15
10
.72
.64
.56
.50
.44
.39
.34
.31
.28
.25
.22
.72
.62
.53
.46
.40
.34
.30
.26
.23
.20
.18
.72
.61
.51
.43
.36
.30
.26
.22
.19
.16
.14
50
10
.79
.67
.57
.48
.42
.35
.31
.27
.24
.21
.18
.69
.62
.54
.48
.42
.37
.33
.30
.27
.24
.22
.69
.60
.52
.45
.39
.33
.29
.26
.22
.20
.17
.69
.59
.50
.42
.36
.30
.26
.22
.19
.16
.14
.68
.58
.48
.41
.34
.29
.24
.21
.18
.15
.13
180-90°
90-0°
180-0°
%
%
LUMENS
LAMP
LUMINAIRE
0
1973
1973
0.0
68.05
68.05
0.0
100.00
100.00
LUMINANCE SUMMARY (fL)
0
45
2023
2413
2902
1367
820
2033
1869
2198
2071
758
ANGLE
45°
55°
65°
75°
85°
90 135 180
541
495
435
368
328
27
30
31
46
83
9
6
8
19
58
ZONAL LUMEN SUMMARY
70
80
50 30
10
70
70
50 30
10
50
50
30
10
50
30
30
10
50
10
30
10
0
0
.67
.62
.57
.52
.48
.43
.40
.37
.34
.31
.29
.67
.60
.52
.46
.41
.36
.32
.29
.26
.23
.21
.67
.55
.45
.38
.32
.27
.24
.21
.18
.15
.13
.66
.61
.55
.50
.46
.42
.39
.36
.33
.30
.28
.66
.58
.51
.45
.40
.35
.32
.29
.25
.23
.21
.66
.54
.45
.38
.32
.27
.23
.20
.18
.15
.13
.63
.56
.49
.44
.39
.34
.31
.28
.25
.22
.20
.63
.54
.46
.40
.35
.30
.26
.23
.21
.18
.16
.63
.53
.44
.37
.32
.27
.23
.20
.18
.15
.13
.60
.54
.47
.42
.37
.33
.30
.27
.24
.22
.20
.60
.52
.45
.39
.34
.29
.26
.23
.20
.18
.16
.60
.51
.43
.37
.31
.27
.23
.20
.17
.15
.13
.58
.52
.46
.41
.36
.32
.29
.26
.23
.21
.19
.58
.51
.44
.38
.33
.29
.25
.23
.20
.18
.16
.58
.49
.42
.36
.31
.26
.23
.20
.17
.15
.13
.57
.48
.41
.35
.30
.25
.22
.19
.16
.14
.12
RCR
0
1
2
3
4
5
6
7
8
9
10
.67
.57
.49
.42
.36
.31
.27
.24
.21
.19
.17
.66
.56
.48
.41
.36
.31
.27
.24
.21
.18
.17
180-90°
90-0°
180-0°
%
%
LUMENS
LAMP
LUMINAIRE
0
3288
3288
0.0
56.69
56.69
0.0
100.00
100.00
LUMINANCE SUMMARY (fL)
0
ANGLE
45°
55°
65°
75°
85°
3499
3564
3673
2864
1119
45
90 135 180
3125 1305 54 17
3236 1163 54 19
3333 963 61 26
2827 703 77 39
1102 569 151 117
Floor Cavity Reflectance 20
ZONAL LUMEN SUMMARY
G-D-1012BX40
58.1 % Efficiency
Litecontrol Certified Test Report #18910000
OUTPUT
LUMENS
23
.79
.65
.53
.44
.37
.31
.27
.23
.20
.17
.15
50
0
0
ZONE
99
136
.79
.70
.61
.53
.47
.41
.37
.33
.29
.26
.24
10
10
30
G-D-1024T8
56.7 % Efficiency
Litecontrol Certified Test Report #18921002
OUTPUT
LUMENS
242
.79
.73
.66
.60
.55
.50
.45
.42
.38
.35
.33
50
30
30
Floor Cavity Reflectance 20
CANDLEPOWER SUMMARY
ANGLE
.81
.68
.58
.49
.42
.36
.31
.27
.24
.21
.18
42
50
10
50
30
RCR
CANDLEPOWER SUMMARY
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
70
70
50 30
ZONE
RCC
RW
70
80
50 30
10
.69
.64
.58
.53
.49
.45
.41
.38
.35
.32
.30
.69
.61
.54
.47
.42
.37
.33
.30
.27
.24
.22
.69
.57
.47
.39
.33
.29
.25
.21
.19
.16
.14
70
70
50 30
10
.68
.62
.57
.52
.48
.43
.40
.37
.34
.31
.29
.68
.60
.53
.46
.41
.37
.33
.29
.26
.24
.22
.68
.56
.46
.39
.33
.28
.24
.21
.18
.16
.14
50
50
30
10
.65
.57
.51
.45
.40
.36
.32
.28
.26
.23
.21
.65
.56
.48
.41
.36
.31
.27
.24
.21
.19
.17
.65
.54
.45
.38
.33
.28
.24
.21
.18
.16
.14
50
30
30
10
.62
.55
.49
.43
.39
.34
.31
.27
.25
.23
.21
.62
.54
.46
.40
.35
.31
.27
.24
.21
.19
.17
.62
.52
.44
.37
.32
.28
.24
.21
.18
.16
.14
50
10
30
10
0
0
.59
.53
.47
.42
.37
.33
.30
.27
.24
.22
.20
.59
.52
.45
.39
.34
.30
.26
.23
.21
.18
.16
.59
.51
.43
.37
.32
.27
.24
.20
.18
.16
.14
.58
.50
.42
.36
.31
.26
.23
.19
.17
.15
.13
RCR
0
1
2
3
4
5
6
7
8
9
10
.69
.59
.50
.43
.37
.32
.28
.25
.22
.19
.17
38
.68
.58
.49
.42
.37
.32
.28
.24
.22
.19
.17
180-90°
90-0°
180-0°
%
%
LUMENS
LAMP
LUMINAIRE
0
1830
1830
0.0
58.11
58.11
0.0
100.00
100.00
LUMINANCE SUMMARY (fL)
ANGLE
45°
55°
65°
75°
85°
45
90 135 180
3759 698
4260 3500
4677 3882
3382 3401
122 463
0
975 81 15
884 94 6
665 99 8
574 120 14
644 203 106
© 2003 LITECONTROL, PDF 203
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
0
0
48
116
237
582
823
919
928
883
959
1038
1174
1359
1503
1454
1135
872
636
407
ZONAL LUMEN SUMMARY
G-D-1014T8
68.0 % Efficiency
Litecontrol Certified Test Report #18911000
CANDLEPOWER SUMMARY
ANGLE
Floor Cavity Reflectance 20
PLANNING FOR INSTALLATION
chain or wire supports
(by others) per local code
Lift fixture diagonally through the opening above ceiling grid. Rest the fixture on
the T-bars so that safety clips straddle T-bars, and fixture support flanges (which
support ceiling tiles) are positioned between T-bars.
18-36"
FROM WALL
FIXTURE
ACCESS
COVER
Loosen access cover screws and remove cover using keyhole openings. Remove
one knockout in cover and attach flexible conduit feed (supplied by electrical
contractor). Remove tape holding fixture wires and make wiring connections. Push
wire connections back into housing and reinstall access cover.
NOTE: For drywall or plaster ceiling installations, a ceiling trim
conversion kit is available. Consult factory.
T-BARS
(by others)
SAFETY CLIP
FIXTURE SUPPORT FLANGE
(to support ceiling tile)
CEILING TILE
100 HAWKS AVENUE
. . . an employee owned company
HANSON
MA
02341
781 294 0100
WALL
REFERENCE
FAX 781 293 2849
info@litecontrol.com
www.litecontrol.com
®
2930 South Fairview Street
Santa Ana, CA 92704
Phone: 714 668 3660
Fax: 714 668 1107
Email: alllighting@earthlink.net
AL- 11
Parking Areas
Roadway
Pedestrian Walkways
Large Areas
Al-11-Y
AL-11-BC
(24" diameter housing only)
Specifications
Certifications
Light Distribution
UL Listed for wet location
The AL-11 luminaire shall meet the specified light distribution and footcandle
levels with an internal optical system and internal lamping.
Assembly Field installation to bracket or pole shall be accomplished without having to
remove or disassemble any fixture components. Fixture shall be UL listed
“suitable for wet locations.”
aluminum.
Door Frame Assembly Aluminum door frame shall be furnished with clear glass fully tempered lens,
thermal and shock resistant. White dacron open cell gasket prevents entry of
moisture, dust and insects. All external hardware shall be stainless steel.
Ballast Ballast shall be readily accessible, removable and insulated. The fixture is to be
pre-wired, completely assembled and electronically tested prior to shipment.
Quick disconnects are standard.
Optical Assembly The optical assembly shall be of all non-ferrous components with a multi
faceted specular finished reflector, rotatable 90°.
Finish BK-BZ-WH-GR-GRAY-NA baked enamel standard, other colors available.
Duranodic® anodized finishes shall be applied over brushed aluminum surfaces
of a uniform fine grain. (Specify baked enamel or anodized finish color).
AL
Housing Luminaire body shall be one piece, heavy gauge, anodizing quality spun
AL- 11
PROJECT
FIXTURE TYPE
CATALOG#
Product Order Guide
Mounting Lamp
Series Type
Watts
AL-11 BC/
100
Y/*
175
250
400
100
150
250
400
Lamp
Ballast
MH
HPS
Primary
Voltage
120
208
240
277
480
Reflector
Type
A
SXII
SXIII
SQ
SQV
Finish
BZ
Bronze
BK
Black
GR Green
WH White
CC Custom Color
BAA Clear Anodize
BZA Bronze Anodize
BKA Black Anodize
NA Natural Aluminum
GRAY
Options
F
Fusing
FF Double Fusing
PCC Photo Control W/Receptacle
PL Polycarbonate Lens Shield
HSS House Side Shield
QS Quartz Standby
Note: Lamps 175 W and below are medium base
Example: AL-11-Y-400MH-120-SXIII-GR-PCC
Reflector Type
Mounting Type
BC
Concealed Hardware Mounting Arm
Y
Yoke Mount
AL
*24" diameter housing only
Type A
Asymmetric Forward Throw
Type SXII
Roadway Type 2 Distribution
Type SXIII
Roadway Type 3 Distribution
Type SQ
Type 5 Square Distribution
Luminaire Dimension
Luminaire
AL-11-70W-175W
AL-11-250W-400W
A
18"
24"
B
11"
15"
Type SQV
Type 5 Vertical Lamp 150HPS
and 175 MH Max Wattage
Weight
60#
72#
EPA
1.10
1.41
A
B
®
2930 South Fairview Street
Santa Ana, CA 92704
Phone: 714 668 3660
Fax: 714 668 1107
Email: alllighting@earthlink.net
© Architectural Landscape Lighting 2003
Due to a program of continuous improvement, Architectural Landscape Lighting reserves the
right to make any variation in design or construction to the equipment described.
®
2930 South Fairview Street
Santa Ana, CA 92704
Phone: 714 668 3660
Fax: 714 668 1107
Email: alllighting@earthlink.net
BL-80/81
Building Mount
Corridor
Walkways
Accent
Building Entrances
Luminaire Dimensions
A
9”
12”
B
8-3/4”
12-1/2”
C
9-3/4”
14-1/2”
BL
Luminaire
BL-80
BL-81
A
Specifications
C
B
Certifications
Ballast Housing
Lens Frame
Lens
Reflector
Up/Down Mounting
Finish
UL- and CUL-listed for wet locations. Also meets IP65 standard
Cast aluminum.
Cast aluminum mounted to ballast housing with stainless steel screws.
The lens shall be clear tempered prismatic glass (BL-80).
The lens shall be clear tempered glass (BL-81).
The reflector shall be an adjustable (40˚) assymetric reflector (BL-81). Optional
spot and flood reflectors available.
Each fixture can be mounted in an upward or downward orientation.
BK-BZ-WH-GR-GRAY-NA baked enamel standard, other colors available.
Product Order Guide
Series
BL-80
BL-81
Wattage &
Source
35HPS
70HPS
70MH
42CFT
Voltage
120
120/277
120/277
120/277
Lens
PG Prismatic Tempered Glass
175MH
150HPS
18LPS
120/277
120/277
120/277
CG Clear Tempered Glass
Finish
BK Black
BZ Bronze
WH White
GR Green
NA Natural Aluminum
GRAY
CC Custom Color
Note: Lamps 175 W and below are medium base
Consult Factory For Other voltages
PROJECT
FIXTURE TYPE
CATALOG#
Options
CG Clear Tempered Glass
PG Prismatic Tempered Glass
ADJ Adjustable Assymetric
SPT Spot 1V1H
FLD Flood 3V3H
WeeBee LED
LED
Design: Paul Sayers
Type:
Project:
Catalog Number:
NOTES:
INSTALLATION IS SUBJECT TO
LOCAL CODES AND JURISDICTION
(3) M4 X 12mm STAINLESS STEEL
SOCKET CAP SCREWS
316 MARINE GRADE STAINLESS STEEL
TOP PLATE BEVELED EDGE, .240" THICK
louis
poulsen
HEAT TEMPERED IMPACT RESISTANT
CLEAR OR FROSTED SODA LIME GLASS,
.197" THICK
Ø3.54"
WATERTIGHT SILICONE GASKET
GROUND LEVEL
0.24" TRIM
PROJECTION
Ø3.00"
SLEEVE
(17) X 0.03W LIGHT EMITTING DIODES
(LED) AVAILABLE IN BLUE, GREEN,
AMBER, WHITE OR RED
LIGHT EMITTING DIODE (LED) PRINTED
CIRCUIT BOARD TRANSFORMER 120V
HIGH PRESSURE DIE CAST ALUMINUM
BODY ANODIZED AND POWDER COATED
WITH PAINT CONTAINING PTFE TO
PROVIDE MAXIMUM CORROSION
PROTECTION
3.70"
316 MARINE GRADE STAINLESS STEEL
SLEEVE WITH WELDED BRACKET FOR
LUMINAIRE ATTACHMENT
9.00"
1/2" NPT NICKEL PLATED BRASS
FEMALE CONDUIT CONNECTOR
FASTENED INTO CAST HOUSING BY
M16 THREAD
1/2" NPT LIQUID TIGHT STRAIGHT-THRU
CONNECTOR (BY OTHERS)
COMPARTMENT TO ALLOW FOR
AMPLE LENGTH OF CABLE FOR
REMOVAL OF INGROUND LUMINAIRE
FROM STAINLESS STEEL SLEEVE
DURING MAINTENANCE
REMOVABLE SLEEVE BOTTOM WITH A
Ø.875" HOLE
WARNING:
A LIQUID TIGHT CONNECTOR MUST BE USED TO PREVENT
MOISTURE PENETRATION INTO THE WIRE COMPARTMENT
LIQUID TIGHT STRAIGHT-THRU CONNECTOR,
FLEXIBLE CONDUIT, RIGID PVC CONDUIT
AND (2) 1/2" NPT CONDUIT CONNECTORS
(BY OTHERS)
Louis Poulsen Lighting, Inc., 3260 Meridian Parkway, Fort Lauderdale, FL 33331 Telephone: (954) 349-2525 Fax: (954) 349-2550
www.louispoulsen.com
03/03
WeeBee LED
Photometric Report:
Report No.:
Poulsen Report No.:
Luminaire:
Lamp:
Efficiency:
Description:
Candlepower Distribution
Vertical Angle
Candela
0
0
10
0
40
0
70
0
110
0
120
0.1
130
0.4
140
0.7
150
2.6
160
8.3
170
10.6
180
9.4
LED
Weebee-LED-White-Clear Glass Top Plate.IES
LP44534a
Weebee-LED-White-Clear Glass Top Plate.IES
Weebee-LED-White-Clear Glass Top Plate.IES
LED White
0.8%
All data shown are per 1000 lumens. This report can be used for calculation on
all versions listed below. Use only actual lumen data when calculating.
Zonal Lumen Summary
Zone
Lumens
0-30
0
0-40
0
0-60
0
0-90
0
90-120
0
90-130
0
90-150
2
90-180
8
0-180
8
% Lamp
0
0
0
0
0
0
0.2
0.8
0.8
% Fixture
0
0
0
0
0
0
25.0
100.0
100.0
WeeBee LED, with 17 light emitting
diodes, is a symmetrical illuminator.
Depending on the chosen shield or
diffuser, the characteristics of the
light can vary. WeeBee LED is suitable
for decorative accent lighting, both
for indoor and outdoor use.
s p e c i f i c a t i o n
Finish
Stainless steel.
1
Product code
WEEBEE
Material
Glass: Tempered clear or frosted
glass. Top plate: Machined marine
grade 316 stainless steel. Body:
Anodized and powder coated paint
containing PTFE, die cast aluminum.
2
Light source
LED Ambera,b
LED Bluea,b
LED Greena,b
LED Reda,b
LED Whitea,b
Mounting
Installation: Suitable for burial in
earth/gravel or cast into concrete.
Sleeve: Recommended mounting in
supplied installation sleeve.
3
Voltage
120V
4
Finish
ST. STEEL
Weight
Max. 3 lbs.
5
Glass
CLEAR
FROSTED
6
Top plate style
BEVELED
STRAIGHT
Label
cUL, Wet location. IBEW.
Ordering example:
1
2
3
Prod.code
Light source
Volt.
WEEBEE
LED Blue
120V
4
Finish
ST. STEEL
5
Glass
CLEAR
6
Top plate
STRAIGHT
Specification notes:
a. Provided with integral pre-assembled
LED board and 120V transformer.
b. LED 50º beam spread provided as
standard.
Info notes:
I. The comparable EU version has the
following classification: Ingress
Protection Code: IP67.
Louis Poulsen Lighting, Inc., 3260 Meridian Parkway, Fort Lauderdale, FL 33331 Telephone: (954) 349-2525 Fax: (954) 349-2550