Covelight 68 ™ FLUORESCENT DIMENSIONAL DATA FEATURES 3.00" 76.2mm 2.125" 53.9mm 5.625" 142.9mm Intended for concealed cove installations where directional light requirements may change. Multiple lamp configurations provide maximum flexibility. Continuous row installations may be configured with combinations of 3’ and 4’ standard length units. Adjustable asymmetric optical system adds flexibility and performance to any design. 7.50" 190.5mm lamping options BIAX LAMPS PERFORMANCE PRODUCT OVERVIEW T8 LAMPS Lumen Output: 2579-4446lm Wattage:33-63W Lamping: T5/T5HO LAMPS Biax, T5, T5HO, T8 fixture information 38" 36" 1–Lamp T8 82% Efficient 3' (3' 2") 50" 48" 1242 cd @ 115˚ (0° tilt) 4' (4' 2") Overall luminaire length will exceed nominal length. Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight Visit focalpointlights.com for complete photometric data. July 2014 C fixture: project: ORDERING DETAILS Luminaire Series Covelight run information 36" 6' 48" 6' 4" Profile 6" x 8" 36" 7' 4" Lamping 40 Watt Biax 50 Watt Biax 55 Watt Biax One Lamp T8 One Lamp T5 One Lamp T5HO 36" 7' 48" 8' 4" 48" 8' 36" 9' 6" 36" Circuits Single Circuit 36" 9' 48" 10' 6" 36" Voltage 120 Volt 277 Volt 347 Volt 36" 10' Fixtures are always independent and never joined. Overall luminaire length will exceed nominal length. Consult factory for additional row length information. Ballast Electronic Instant Start (T8 Only) (maximum <20% THD) 68 Mounting Cove Construction 20 Ga. steel reflector housing and remote ballast housing. 16 Ga. steel end plates attached to housing. Luminaires available in 3’ and 4’ nominal lengths only. 3’ unit weight: 12 lbs. 4’ unit weight: 16 lbs Optic Die-formed .02” specular aluminum reflector. Electrical Electronic ballasts are thermally protected and have a Class “P” rating. Optional dimming ballasts available. Consult factory for dimming specifications and availability. 68 BX40 BX50 BX55 1T8 1T5 1T5HO 1C 1C 120 277 347 E CV Factory Options Emergency Battery Pack* HLR/GLR Fuse Include 3000K Lamp* Include 3500K Lamp* Include 4100K Lamp* EM FU L830 L835 L841 Finish High Reflectance White HW Luminaire Length 3' 4' Labels (Note: Overall luminaire length will exceed nominal length.) 3' 4' Finish Polyester powder coat applied over a 5-stage pre-treatment. Standard luminaire housing finished in High Reflectance White. Focal Point LLC reserves the right to change specifications for product improvement without notification. FCV Electronic Program Start <10% THD S Electronic Dimming Ballast* D SPECIFICATIONS UL and cUL listed. FCV *For more information visit focalpointlights.com/reference or consult factory. CV HW Covelight 68 ™ FCV-68-1T8-1C-120-E-HW-4’ FLUORESCENT ADJUSTABLE CANDELPOWER DISTRIBUTION 180° 170° 160° 150° 1245 0° 0˚ 0 0 0 0 0 5˚ 0 0 0 0 0 120° 15˚ 0 0 0 0 110° 25˚ 0 0 0 35˚ 0 0 130° 996 747 498 249 100° Zonal Lumens % Lamp % Fixture 39.7 48.7 0 90°-130° 1431 50.2 61.6 0 0 90°-150° 1884 66.1 81.0 0 0 0 90°-180° 2105 73.9 90.6 0 0 0 0 2324 82 100.0 0 0 0 0 0 0 55˚ 17 8 0 0 0 2 249 80° 65˚ 72 47 12 0 0 12 498 70° 75˚ 243 208 103 1 0 55 747 60° 85˚ 530 462 276 91 0 151 0 0° 0° 45° 90° 10° 20° 30° 40° 90° 45° 0° 82% 1131 45˚ 1245 2324lm Efficiency Lumens 90° 50° Lumens: 8815.0 90°-120° 90° 0 996 FCV681T8.IES Test #: LUMEN SUMMARY Horizontal Angle 22.5° 45° 67.5° Vertical Angle 140° Filename: 90˚ 903 813 557 201 95˚ 1126 1030 728 307 8 365 105˚ 1215 1115 817 342 51 385 115˚ 1242 1122 741 413 89 381 125˚ 983 895 706 443 118 300 135˚ 907 847 688 455 142 255 145˚ 798 755 630 464 171 198 155˚ 691 658 590 390 183 130 165˚ 594 522 469 341 195 72 175˚ 295 283 254 219 195 20 180˚ 198 198 198 198 198 Zone Total Luminaire 0°-180° Go to www.focalpointlights.com for additional photometric data. note: Photometric testing performed in an independent lab with standard lamps and ballasts. Lamp and ballast type and configuration will affect photometric performance. Covelight ™ Fluorescent run Guide Continuous Runs consist of standard fixture lengths. Some fixtures may exceed nominal length consult individual cut sheets for details. Example: 31' run = three 8' fixtures and one 7' fixture. Nominal run length (in feet) Standard fixture lengths required Lamp sizes Nominal run length (in feet) Standard fixture lengths required Lamp sizes 2 2 2 32 8888 44444444 3 3 3 33 88863 444444333 4 4 4 34 88864 444444433 5 5 5 35 88883 444444443 6 6 33 36 88884 444444444 7 7 43 37 88867 4444444333 8 8 44 38 88886 4444444433 9 63 333 39 88887 4444444443 10 64 334 40 88888 4444444444 11 83 443 41 888863 44444444333 12 84 444 42 888864 44444444433 13 76 4333 43 888883 44444444443 14 86 4433 44 888884 44444444444 15 87 4443 45 888876 444444444333 16 88 4444 46 888886 444444444433 17 863 44333 47 888887 444444444443 18 864 44433 48 888888 444444444444 19 883 44443 49 8888863 4444444444333 20 884 44444 50 8888873 4444444444433 21 876 444333 22 886 444433 23 887 444443 24 888 444444 25 8863 4444333 26 8864 4444433 27 8883 4444443 28 8884 4444444 29 8876 44444333 30 8886 44444433 31 8887 44444443 Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight