Application Note 1 Spectra Wiring diagram DC Input and Output

advertisement
Application Note 1
Spectra Wiring diagram
Introduction
Spectra LED Driver is an Intelligent LED Driver Designed for Colour Mixing Applications.
This Application Note (AN1 Spectra Wiring Diagram) provides technical information for the wiring connection and
mounting of the Spectra LED Driver (all models)
Spectra LED Driver has one input connector and four output connectors for LEDs connection and LED thermal
protection. It has also several connectors for communication and controls.
This document describes how to connect the Spectra LED Driver (DC Input, Output Channels, Communication
and Controls).
The last part of the document contains useful suggestions regarding the fixing of the Spectra LED Driver to the
host system.
DC Input and Output Channels Overview
The figures below show the DC input Connector and the 4 Output Connectors, one for each Output Channel.
Figure 1: Input DC Connector
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Figure 2: Output DC Connectors
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Application Note 1
Spectra Wiring diagram
DC Input Connection
Spectra LED Driver is powered by a DC Input. The DC Input Voltage comes whether from a AC-DC Power Supply
or from a low voltage DC bus. Refers to the Figure 3 or 4 for the DC Input connection polarity.
Please consult the Spectra datasheet for the Input Voltage and Current ratings.
+Vin
RTN
+Vin RTN
Figure 3: Input DC Connector and polarity
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Figure 4: Input DC Connector and polarity
(Open Frame Model RSPT190-OPEN)
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 2/8
Application Note 1
Spectra Wiring diagram
Output Channels Connection
Spectra LED Driver has 4 independent output channels.
Each output channel has a dedicated 4-vie colour coded connector (figures 5 and 6) for easy and intuitive
connection. Please Consult the Spectra datasheet for the Output Voltage and Current ratings.
C
H
A
N
N
E
L
C
H
A
N
N
E
L
C
H
A
N
N
E
L
C
H
A
N
N
E
L
4
3
2
1
Figure 5: Output Channels Connectors
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
C
H
A
N
N
E
L
C
H
A
N
N
E
L
C
H
A
N
N
E
L
C
H
A
N
N
E
L
4
3
2
1
Figure 6: Output Channels Connectors
(Open Frame Model RSPT190-OPEN)
Each Spectra output channel provides the controlled current to a LED String and can also be connected to a
Negative Temperature Coefficient sensor (NTC) dedicated to the channel, as showed in the figures 7 and 8.
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 3/8
Application Note 1
Spectra Wiring diagram
CHANNEL 1
LEDn .....LED1
NTC1
CHANNEL 4
LEDn .....LED1
NTC4
Figure 7: Output Wiring (Boxed Models RSPT190-BWOD and RSPT190-BWD)
CHANNEL 1
LEDn .....LED1
NTC1
CHANNEL 4
LEDn ....LED1
NTC4
Figure 8: Output Wiring (Open Frame Model RSPT190-OPEN)
The NTC can be mounted to the LED Board Assembly to realize a thermal feedback in order to have an Over
Temperature Protection of LEDs.
Up to 4 NTCs (one for each output channel) can be connected to Spectra, as showed in the figures 7 and 8.
See the Application Note 2 “AN2 Spectra Temperature Sense” for the correct NTC choice.
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 4/8
Application Note 1
Spectra Wiring diagram
DMX/RDM Connection
Spectra LED Driver can work in the Stand Alone mode (only 1 Spectra is used), in the Master-Slave mode or can
be remotely controlled through the DMX/RDM communication. It has also several analog and digital
Input/Outputs for the display connection or for OEM Options.
DMX IN and DMX OUT Signals are available in the connector called “DMX” and showed in the figures 9 and 10.
The connection can be easily realized by using the DMX Cabling (available as optional); this cable can be ordered
apart (Code RHSM000175), as written in the Spectra Datasheet.
B A
B A
B A
DMX Cable
RHSM000175
DMX IN DMX OUT
DMX Cable
RHSM000175
DMX IN DMX OUT
Figure 9: DMX/RDM Connector
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
B A
Figure 10: DMX/RDM Connector
(Open Frame Model RSPT190-OPEN)
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 5/8
Application Note 1
Spectra Wiring diagram
Display/Keyboard Connection
Spectra LED Driver can be used also with the Display/Keyboard that allows the setting of the main product
parameters.
The Display/Keyboard module is already included in the Model RSPT190-BWD and its is available as optional in
the models RSPT190-BWOD and RSPT190-OPEN, as showed in the Spectra Datasheet (Options section).
When the Display is used as optional, it can be connected with Spectra by using the dedicated Display Cable
(available as optional, Code RHSM000229), as showed in the figures 11 and 12.
Display Cable
RHSM000229
Display Cable
RHSM000229
Display / Keyboard
RHPS218
Display / Keyboard
RHPS218
Figure 11: Display Connector
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Figure 12: Display Connector
(Open Frame Model RSPT190-OPEN)
Other Connectors
Spectra LED Driver has other connectors (AUX, IR1,IR2) not explained in this document, in fact it is able to work
with several Input/Output Sensors digital and analog. Moreover Spectra is able to receive the signal that comes
from InfraRed sensor.
All these connectors are intended for OEM uses or factory reserved; see the Spectra Datasheet, OEM Options
section.
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 6/8
Application Note 1
Spectra Wiring diagram
Mounting Spectra LED Driver
Spectra is designed for convection cooled operation, therefore the LED Driver mounting does not require
heatsink. The mounting surface has to be flat and it can be metallic or plastic.
It is recommended to guarantee that the Ambient Temperature is within the range specified in the Spectra
Datasheet. The mounting position (vertical, horizontal) does not influence the temperature (TBV).
Spectra LED Driver is made to be fixed on a flat surface through 2 x M4 screws.
Figures 13 and 14 show how to mount the enclosed version models.
Figure 13: Mounting, Input Side screw
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Figure 14: Mounting, Output Side screw
(Boxed Models RSPT190-BWOD and RSPT190-BWD)
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 7/8
Application Note 1
Spectra Wiring diagram
Figures 15 and 16 show how to mount the Spectra open frame model on a host surface.
The recommended distances (expressed in millimeters) to respect are specified in figure 17.
Host Surface
Host Surface
Figure 15: Fixing the Spectra Open Frame (RSPT190OPEN) on a host surface
Figure 16: Fixing the Spectra Open Frame
(RSPT190-OPEN) on a host surface
Host Surface
Figure 17: Spectra Open Frame (RSPT190-OPEN) mounted on a host surface;
distances are expressed in millimetres
Roal Electronics, S.p.A. may change product specifications and accordingly the information presented in this document. Customers are responsible for
their products and applications using Roal Electronics, S.p.A. products. Roal Electronics, S.p.A. assumes no liability from the use of its products outside
of specifications. No license is granted to any intellectual property rights by this document. ROAL ELECTRONICS, S.P.A. DISCLAIMS ALL
REPRESENTATIONS AND WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED
WARRANTIES OF NONINFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Eu and RoW
ROAL Electronics S.p.A
Via Jesina 56/A
60022 – Castelfidardo (AN) - Italy
Tel:+39 071 721461
Fax:+ 39 071 72146 480
North America
www.roallivingenergy.com
ROAL Electronics USA, Inc.
701, Main St. Suite 405
Stroudsburg, PA18360
Phone: + 1 570 421 5750
Fax: +1 570 421 5687
Rev. 01 – 03 Aug. 2011 - Pag. 8/8
Download