HH4SQ-LED 4” ARCHITECTURAL LED SQUARE DOWNLIGHT HH4SQ-LED Catalog Number Type Project Name NE W A Height = 5-1/2” B Trim Aperture = 4-1/2” C Cut-out = 5-1/8” D Trim Outside Dia. = 5-3/4” E Width = 7-3/4” F Length = 7-1/8” 900 G Max. Length = 10” INPUT VOLT. INPUT FREQ. INPUT CUR. INPUT POWER THD POWER FACTOR LUMENS 120/277 120/277 50/60Hz 50/60Hz 133mA/57mA 116mA/50mA 16W(+/-5%) 14W(+/-5%) <20% <20% >0.9 >0.9 900 600 G DESCRIPTION - 4” Square LED dedicated New Construction housing with integral LED heat management casting and driver (installed on junction box). Available in 600 lumens (14W) & 900 lumens (16W). Lighting is smooth and comfortable while using 75% less energy than the equivalent 65W BR30 and 25% less than the common 18W CFL. Plus, the eco-friendly MAXILUME LED system features 70% lumen maintenance at 50,000 hours life, with Energy Star and California Title-24 (compliances pending). FEATURES - Greater light output than an 18W CFL or a 65W BR30 while consuming less than 14W & 16W of power. MAXILUME LED luminaires are ideally suited for use in hospitality, health care, commercial, institution, retail and residential applications. PENDING OPTICS - Anyone can mount a chip to a heat sink and make a downlight. Gather the light scattered by the LED chip, shape it into a functional beam with state of the art reflectors, integrate the light through a smooth lens to minimize brightness, then top it all of with a glare reducing reflector that has a 55-degree cut-off. Now you have the Elite engineered superior quality, light engine; producing 600 lumens (14W) & 900 lumens (16W). MOUNTING FRAME - Die-formed construction for maximum heat dissipation and rust protection. DURABILITY - Die-cast aluminum housing and heat management system are engineered for extremely long life and service period. Heat sink is attached to top of housing. The LED light engine is attached to the die-cast heat sink and is easily replaceable and upgradable. Life tests have shown the Elite light engine output will be maintained at 70% of initial at 50,000 hours of operation. Our LED driver is rated for 50 to 60 Hz at 120V input, produces less than 20% THD, has a power factor between 0.90 and 1.00 and is thermally protected for additional safety. Elite’s driver is installed on the junction box cover so it may be serviced from below the ceiling. RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame, for effortless and tool-less installation. REPEATABLE - Repeatability means quality. From our chip selection process, to our driver, to the thermal management, the MAXILUME LED Module is engineered for quality. All MAXILUME LED luminaries are rated at 85+ CRI and tested to LM-79 and LM-80 standards by a certified laboratory. California Title-24-2008 and Energy Star compliance are standard. DIMMABLE - The MAXILUME LED system is fully dimmable down to 10% of initial light output with a 0-10 Volt dimmer when ordered with the following options (DIM10-120, DIM10-277). Fixtures can be shipped with a Lutron Hi-lume A series Driver which can be dimmed with Lutron Dimming Systems when ordered with the following options (LUTH-120, LUTH-277). Triac & Electronic Low Voltage dimming driver also available when ordered with the following options (DIMTR-120). Consult Factory for details. MOUNTING BRACKET - Constructed from 16 gauge steel. Can be installed with 3/4” or 1-1/2” lathing channel, 1/2” EMT, or with optional C-channel mounting bars (Part# BP31) ordered separately. Housing can be adjusted from the inside of the ceiling. JUNCTION BOX - UL Listed for through-branch circuit wiring, provided with four ½” knockouts, one ¾” knockout and four Romex knockouts with true pry-out slots and strain clamps. Designed for straight through conduit runs. Driver is installed on the junction box cover so it may be serviced from below the ceiling. THERMAL PROTECTION - Standard thermal protection device guards against improper installation and misuse of insulation material. OUR WORD - The MAXILUME LED lighting system is warranted for 5 years. As a system, we stand behind the entire MAXILUME product from housing to bar hangers. LISTING c-UL-us / c-ETL-us - listed for Damp location. Feed Through Wiring. LM79 / LM80 DIMMING INFORMATION DIMTR (Triac & Electronic Low Voltage Dimming) DIM10 (0-10V Dimming) LUTH (Lutron® Hi-lume® Dimming) HH4SQ-LED Example: HH4SQ-LED-16W-DIM10-120-30K-LED-4601-CL-WH TYPE 600 LUMENS 900 LUMENS HH4SQ-LED o 14W-DIMTR-120 o 16W-LUTH-120 o 14W-LUTH-120 o 16W-LUTH-277 o 14W-LUTH-277 o 16W-DIM10-120 o 14W-DIM10-120 o 16W-DIM10-277 o 14W-DIM10-277 42 COLOR o 27K o 30K o 35K o 40K o 50K EMERGENCY o EMG-LED (Must have ceiling access for maintenance) OPTION o BP31 (C-CHannel Bar Hanger) TRIM TYPE o LED-4601 o LED-4607 WWW.MAXILUME.COM • TEL 1-877-375-5555 • FAX 1-877-375-3333 o LED-4614 o LED-4615 REFLECTOR/ RING FINISH o CL-WH o W-WH o CL-SCH o MB-WH o SHZ-SHZ o WT-WH o SHZ-WH ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING 4” LED SQUARE OPTICS LED-4601-CL - REFLECTOR REFLECTOR/ RING FINISH: CL-WH CL-SCH SHZ-WHWT-WH W-WHSHZ-SHZ MB-WH A = 3-1/8” B = 5-3/4” C = 4-5/8” CL WT MB SHZ W LED-4607-CL - WALL WASH REFLECTOR WITH LENS REFLECTOR/ RING FINISH: CL-WH CL-SCH SHZ-WHWT-WH W-WHSHZ-SHZ MB-WH A = 3-1/8” B = 5-3/4” C = 4-5/8” CL WT MB SHZ W LED-4614-CL - REFLECTOR WITH FROSTED GLASS LENS REFLECTOR/ RING FINISH: CL-WH CL-SCH SHZ-WHWT-WH W-WHSHZ-SHZ MB-WH A = 3-1/8” B = 5-3/4” C = 4-5/8” CL WT MB SHZ W LED-4615-CL - REFLECTOR WITH TEMPERED GLASS LENS REFLECTOR/ RING FINISH: CL-WH CL-SCH SHZ-WHWT-WH W-WHSHZ-SHZ MB-WH A = 3-1/8” B = 5-3/4” C = 4-5/8” CL ALL PRODUCTS ARE U.S. AND FOREIGN PATENT PENDING WWW.MAXILUME.COM • TEL 1-877-375-5555 • FAX 1-877-375-3333 WT MB SHZ W 43 HH4SQ-LED-14W-4601-SHZ-SHZ INPUT WATTS: 14 LUMENS: 580 Zonal Lumens Summary Candle Power Distribution (Candelas) Zone 90º 0-20 0-30 0-40 0-60 0-80 0-90 80º 97 70º 194 CRI: +85EFFICACY: 41.42 60º Lumens Luminance (Average candela/M2) %Lamp 138.47 294.80 437.23 556.11 580.21 580.49 %Fixt 23.90 50.80 75.40 95.90 100.00 100.10 23.90 50.80 75.30 95.80 100.00 100.00 Angle in Degrees Average Average Average 0º 45º 90º 45 55 65 75 85 17185 8503 5787 0 0 50º 290 TEST NO.: ELT-261 CCT: 4000K 7602 5082 3405 1866 0 SPACING CRITERIA: 1.24 Lumens Per Zone 9846 9144 4869 2203 367 40º Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30º 387 20º 10º 80% 70% 50% 30% 10% RC RW Cone of Light 22.5 5.6 2.5 12.9’ 25.9’ 38.8’ 16.0 20.0 1.4 0.9 51.7’ 64.6’ Distance to Plane Initial Footcandle at Nadir Beam diameter 0 1 2 3 4 5 6 7 8 9 10 ROOM CAVITY RATIO 4.0 8.0 12.0 BEAM DIA. MEASURED AT 50% OF NADIR F.C. 119 112 105 98 92 86 81 76 71 67 64 119 109 99 91 83 76 70 65 60 56 52 LUMENS: 220 Candle Power Distribution (Candelas) Zone 0-20 0-30 0-40 0-60 0-80 0-90 80º 67 116 110 103 96 90 84 79 74 70 66 62 116 107 98 89 82 75 69 64 60 56 52 70º 60º 116 102 89 79 71 64 58 53 48 44 41 111 103 94 86 79 73 68 63 58 54 51 CRI: +85EFFICACY: 20 Lumens 83.33 141.79 178.86 211.19 219.73 219.86 111 101 91 82 74 67 62 57 52 48 45 111 99 87 78 70 63 57 52 48 44 41 %Lamp %Fixt 38.00 64.60 81.50 96.30 100.20 100.20 37.90 64.50 81.40 96.10 99.90 100.00 Angle in Degrees Average Average Average 0º 45º 90º 45 55 65 75 85 6756 3118 1962 0 0 2751 3062 2995 1851 0 4028 4092 3454 2717 0 40º 268 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30º 10º 20º RC RW Cone of Light 16.39 4.10 1.82 8.9’ 17.9’ 26.8’ 16.0 20.0 1.02 0.66 35.8’ 44.7’ Distance to Plane Initial Footcandle at Nadir Beam diameter 0 1 2 3 4 5 6 7 8 9 10 ROOM CAVITY RATIO 4.0 8.0 12.0 BEAM DIA. MEASURED AT 50% OF NADIR F.C. 80% 70% 50% 30% 10% 119 113 107 101 95 90 85 81 77 73 70 LUMENS: 459 Candle Power Distribution (Candelas) 90º 80º 78 70º 155 119 107 97 88 81 75 69 64 60 57 53 60º 70% 70% 50% 30% 10% 119 105 93 84 76 70 65 60 56 52 49 RC - Ceiling Cavity Reflectance HH4SQ-LED-14W-4614-SHZ-SHZ INPUT WATTS: 14 119 110 101 94 87 81 76 71 67 63 59 117 111 104 99 93 88 84 79 76 72 69 117 108 100 92 86 80 75 70 66 62 59 0-20 0-30 0-40 0-60 0-80 0-90 117 103 92 83 76 70 64 60 56 52 49 111 104 96 90 84 78 73 69 65 61 58 112.07 231.16 339.89 440.77 458.90 459.07 111 102 93 85 79 73 68 63 59 56 53 111 100 90 82 75 69 64 59 56 52 49 24.40 50.40 74.10 96.10 100.00 100.10 %Fixt 24.40 50.40 74.00 96.00 100.00 100.00 Angle in Degrees Average Average Average 0º 45º 90º 45 55 65 75 85 12605 6902 4266 0 0 11634 5006 2648 1285 0 9821 7176 2726 1068 167 40º Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30º 10º 20º RC RW Cone of Light 4.0 8.0 12.0 19.07 4.77 2.12 13.8’ 27.7’ 41.5’ 16.0 20.0 1.19 0.76 55.3’ 69.1’ Distance to Plane Initial Footcandle at Nadir Beam diameter BEAM DIA. MEASURED AT 50% OF NADIR F.C. ROOM CAVITY RATIO 311 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 119 112 105 98 92 86 81 76 71 67 64 119 109 99 91 83 76 70 65 60 56 52 119 106 94 85 76 69 63 58 53 49 46 RC - Ceiling Cavity Reflectance 30% 50% 30% 10% 106 99 91 84 77 71 66 62 57 54 50 106 97 88 80 73 66 61 56 52 48 45 0 5 15 25 35 45 55 65 75 85 90 360 361 360 331 250 125 50 25 0 0 0 10% 50% 30% 10% 106 96 85 77 69 62 57 52 48 44 41 102 95 88 82 75 70 65 60 56 53 49 102 94 86 78 71 65 60 55 51 48 44 102 93 84 75 68 62 56 52 48 44 41 0% 0% 100 91 82 74 66 60 55 50 46 42 39 TEST NO.: ELT-264 SPACING CRITERIA: 0.76 Lumens Per Zone Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 24.26 59.07 58.45 37.07 21.57 10.77 6.40 2.13 0.13 30% 50% 30% 10% 107 100 93 87 81 76 72 68 64 60 57 107 98 91 83 77 72 67 63 59 56 52 Candela Tabulation 0 0 5 15 25 35 45 55 65 75 85 90 10% 50% 30% 10% 107 97 88 80 74 68 63 59 55 52 49 102 97 90 85 80 75 70 66 63 60 57 102 95 88 82 76 71 66 62 58 55 52 102 94 86 79 73 68 63 59 55 52 49 262 266 252 182 101 49 18 8 0 0 0 0% 0% 100 92 85 78 71 66 61 57 54 50 47 119 103 90 80 71 64 58 53 48 44 41 70% 70% 50% 30% 10% 116 110 103 96 90 84 79 74 70 66 62 116 107 98 89 82 75 69 64 60 55 52 116 104 93 84 75 68 62 57 53 49 45 RW - Wall Reflectance 116 102 89 79 71 64 58 52 48 44 41 TEST NO.: ELT-265 CCT: 4000K Luminance (Average candela/M2) %Lamp 50º 233 117 105 96 87 80 74 69 64 60 56 53 50% 50% 30% 10% CRI: +85EFFICACY: 32.78 Lumens 34.80 103.67 156.33 142.43 80.08 38.80 19.59 4.51 0.28 Candela Tabulation 0 RW - Wall Reflectance Zonal Lumens Summary Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 CCT: 4000K Luminance (Average candela/M2) 50º 201 116 104 93 84 76 69 63 57 53 49 45 50% 50% 30% 10% Lumens RW - Wall Reflectance Zonal Lumens Summary 90º 134 119 103 90 80 71 64 58 53 48 44 41 RC - Ceiling Cavity Reflectance HH4SQ-LED-14W-4607-SHZ-SHZ INPUT WATTS: 14 119 106 94 85 76 69 63 58 53 49 46 70% 70% 50% 30% 10% Zone 50% 50% 30% 10% 111 103 94 86 79 73 68 63 58 54 51 111 101 90 82 74 67 62 57 52 48 45 111 99 87 78 70 63 57 52 48 44 41 SPACING CRITERIA: 0.74 Lumens Per Zone Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 29.06 83.01 119.09 108.73 66.74 34.14 15.15 2.98 0.16 30% 50% 30% 10% 106 99 91 84 77 71 66 61 57 53 50 106 97 88 80 73 66 61 56 52 48 45 106 96 85 76 69 62 57 52 48 44 41 Candela Tabulation 0 0 5 15 25 35 45 55 65 75 85 90 10% 50% 30% 10% 102 95 88 81 75 70 65 60 56 53 49 102 94 86 78 71 65 60 55 51 47 44 102 93 84 75 68 62 56 52 47 44 41 305 302 286 242 171 91 40 18 0 0 0 0% 0% 100 91 82 73 66 60 55 50 46 42 39 HH4SQ-LED-16W-4601-SHZ-SHZ INPUT WATTS: 16.4 LUMENS: 911 Candle Power Distribution (Candelas) 90º 80º 151 70º 302 60º CRI: +85EFFICACY: 57 Zonal Lumens Summary Zone 0-20 0-30 0-40 0-60 0-80 0-90 Lumens 221.90 470.38 686.93 871.79 910.53 910.98 Luminance (Average candela/M2) %Lamp 24.40 51.70 75.50 95.80 100.00 100.10 %Fixt 24.40 51.60 75.40 95.70 100.00 100.00 50º 454 Angle in Degrees Average Average Average 0º 45º 90º 45 55 65 75 85 28465 13795 9647 0 0 15081 8493 5673 3282 0 15960 14875 7641 3447 501 40º 605 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30º 10º 20º RC RW 4.0 8.0 12.0 36.7 9.2 4.1 13.2’ 26.4’ 39.6’ 16.0 20.0 2.3 1.5 52.7’ 65.9’ Distance to Plane Initial Footcandle at Nadir Beam diameter ROOM CAVITY RATIO Cone of Light BEAM DIA. MEASURED AT 50% OF NADIR F.C. 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 119 112 105 98 92 86 81 76 72 68 64 LUMENS: 372 Candle Power Distribution (Candelas) 90º 80º 107 70º 214 119 106 94 85 76 69 63 58 53 49 46 60º 70% 70% 50% 30% 10% 119 103 90 80 71 64 58 53 49 45 41 RC - Ceiling Cavity Reflectance HH4SQ-LED-16W-4607-SHZ-SHZ INPUT WATTS: 16.4 119 109 99 91 83 76 70 65 60 56 53 116 110 103 96 90 85 79 75 70 66 63 116 107 98 89 82 75 70 64 60 56 52 0-20 0-30 0-40 0-60 0-80 0-90 111 103 94 87 80 73 68 63 59 55 51 CRI: +85EFFICACY: 23.25 Lumens 137.38 233.90 294.29 357.24 372.25 372.45 111 101 91 82 74 68 62 57 53 49 45 111 99 87 78 70 63 57 53 48 44 41 36.90 62.90 79.20 96.10 100.10 100.20 %Fixt 36.90 62.80 79.00 95.90 99.90 100.00 Angle in Degrees Average Average Average 0º 45º 90º 45 55 65 75 85 9875 2463 1992 0 0 5260 1997 805 555 0 2720 580 83 75 67 40º 429 Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30º 10º 20º RC RW 4.0 8.0 12.0 36.7 9.2 4.1 13.2’ 26.4’ 39.6’ 16.0 20.0 2.3 1.5 52.7’ 65.9’ Distance to Plane Initial Footcandle at Nadir Beam diameter ROOM CAVITY RATIO Cone of Light BEAM DIA. MEASURED AT 50% OF NADIR F.C. 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 119 113 106 100 95 89 84 80 76 72 69 LUMENS: 709 Candle Power Distribution (Candelas) 90º 80º 125 70º 250 119 107 96 88 80 74 68 63 59 56 52 60º 70% 70% 50% 30% 10% 119 105 93 83 75 69 63 59 55 51 48 RC - Ceiling Cavity Reflectance HH4SQ-LED-16W-4614-SHZ-SHZ INPUT WATTS: 16.4 119 110 101 93 86 80 75 70 66 62 59 116 110 104 98 93 88 83 79 75 71 68 116 108 99 92 85 79 74 69 65 61 58 0-20 0-30 0-40 0-60 0-80 0-90 116 103 92 82 75 69 63 59 55 51 48 111 104 96 89 83 77 72 68 64 60 57 180.76 369.00 531.24 681.18 708.55 708.81 111 102 92 85 78 72 67 62 58 55 52 111 100 90 81 74 68 63 58 54 51 48 Luminance (Average candela/M ) %Lamp 25.50 52.10 75.00 96.20 100.10 100.10 %Fixt 25.50 52.10 74.90 96.10 100.00 100.00 Angle in Degrees Average Average Average 0º 45º 90º 45 55 65 75 85 21309 11607 7297 0 0 17938 8131 4291 2087 0 15485 11184 4078 1559 234 40º Coefficients of Utilization - Zonal Cavity Method Effective Floor Cavity Reflectance 0.20 30º 10º 20º RC RW Cone of Light 4.0 8.0 12.0 30.9 7.7 3.4 13.3’ 26.5’ 39.8’ 16.0 20.0 1.9 1.2 53.0’ 66.3’ Distance to Plane Initial Footcandle at Nadir Beam diameter BEAM DIA. MEASURED AT 50% OF NADIR F.C. ROOM CAVITY RATIO 500 0 1 2 3 4 5 6 7 8 9 10 80% 70% 50% 30% 10% 119 112 105 99 92 87 81 76 72 68 64 119 109 100 91 83 77 71 65 61 57 53 119 106 95 85 77 70 64 58 54 50 46 RC - Ceiling Cavity Reflectance Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 56.21 165.69 248.48 216.55 122.47 62.39 31.49 7.25 0.45 30% 50% 30% 10% 106 99 91 84 77 72 66 62 58 54 50 106 97 88 80 73 67 61 56 52 48 45 106 96 85 77 69 63 57 52 48 44 41 Candela Tabulation 0 0 5 15 25 35 45 55 65 75 85 90 10% 50% 30% 10% 102 95 88 82 75 70 65 60 56 53 50 102 94 86 78 72 66 60 56 51 48 45 102 93 84 75 68 62 57 52 48 44 41 587 588 585 551 419 207 81 42 0 0 0 0% 0% 100 91 82 74 67 60 55 50 46 43 39 TEST NO.: ELT-00251 SPACING CRITERIA: 1.00 Lumens Per Zone Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 39.63 97.75 96.52 60.40 39.67 23.28 11.96 3.04 0.21 30% 50% 30% 10% 107 100 93 86 81 76 71 67 63 59 56 107 98 90 83 76 71 66 62 58 54 51 107 97 88 80 73 67 62 58 54 51 48 Candela Tabulation 0 0 5 15 25 35 45 55 65 75 85 90 10% 50% 30% 10% 102 96 90 84 79 74 69 66 62 59 56 102 95 88 81 75 70 65 61 57 54 51 102 94 86 78 72 67 62 58 54 51 48 428 426 405 313 180 72 14 8 0 0 0 0% 0% 100 92 84 77 71 65 60 56 52 49 46 119 104 91 80 72 64 58 53 49 45 42 70% 70% 50% 30% 10% 116 110 103 97 90 85 80 75 71 67 63 116 107 98 89 82 76 70 65 60 56 53 116 104 93 84 76 69 63 58 54 50 46 RW - Wall Reflectance TEST NO.: ELT-00252 CCT: 4000K 2 50º 375 116 105 95 87 79 73 68 63 59 55 52 50% 50% 30% 10% CRI: +85EFFICACY: 44.30 Lumens Zone RW - Wall Reflectance Zonal Lumens Summary Zone Lumens Per Zone CCT: 4000K Luminance (Average candela/M2) %Lamp 50º 321 116 102 89 79 71 64 58 53 48 45 41 50% 50% 30% 10% SPACING CRITERIA: 1.26 RW - Wall Reflectance Zonal Lumens Summary Zone 116 104 93 84 76 69 63 58 53 49 46 TEST NO.: ELT-00250 CCT: 4000K 116 102 90 79 71 64 58 53 49 45 42 50% 50% 30% 10% 111 103 94 87 80 74 68 63 59 55 52 111 101 91 82 74 68 62 57 53 49 46 111 99 88 78 70 64 58 53 49 45 42 SPACING CRITERIA: 1.12 Lumens Per Zone Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 47.03 133.73 188.25 162.23 98.59 51.36 22.80 4.57 0.26 30% 50% 30% 10% 106 99 91 84 78 72 67 62 58 54 51 106 97 88 80 73 67 61 57 52 49 45 106 96 86 77 69 63 57 53 48 45 41 Candela Tabulation 0 0 5 15 25 35 45 55 65 75 85 90 10% 50% 30% 10% 102 96 89 82 76 70 65 61 57 53 50 102 94 86 79 72 66 61 56 52 48 45 102 93 84 76 69 62 57 52 48 45 41 494 491 467 405 291 155 68 31 0 0 0 0% 0% 100 91 82 74 67 61 55 51 47 43 40