4 - Elite Lighting

advertisement
HH4SQ-LED 4” ARCHITECTURAL
LED SQUARE DOWNLIGHT
HH4SQ-LED
Catalog Number
Type
Project Name
NE
W
A Height = 5-1/2”
B Trim Aperture = 4-1/2”
C Cut-out = 5-1/8”
D Trim Outside Dia. = 5-3/4”
E Width = 7-3/4”
F Length = 7-1/8”
900
G Max. Length = 10”
INPUT VOLT.
INPUT FREQ.
INPUT CUR.
INPUT POWER
THD
POWER FACTOR
LUMENS
120/277
120/277
50/60Hz
50/60Hz
133mA/57mA
116mA/50mA
16W(+/-5%)
14W(+/-5%)
<20%
<20%
>0.9
>0.9
900
600
G
DESCRIPTION - 4” Square LED dedicated New Construction housing with integral LED heat management casting and driver (installed on junction box). Available in 600
lumens (14W) & 900 lumens (16W). Lighting is smooth and comfortable while using 75% less energy than the equivalent 65W BR30 and 25% less than the common 18W
CFL. Plus, the eco-friendly MAXILUME LED system features 70% lumen maintenance at 50,000 hours life, with Energy Star and California Title-24 (compliances pending).
FEATURES - Greater light output than an 18W CFL or a 65W BR30 while consuming less than 14W & 16W of
power. MAXILUME LED luminaires are ideally suited for use in hospitality, health care, commercial, institution, retail
and residential applications.
PENDING
OPTICS - Anyone can mount a chip to a heat sink and make a downlight. Gather
the light scattered by the LED chip, shape it into a functional beam with state of
the art reflectors, integrate the light through a smooth lens to minimize brightness,
then top it all of with a glare reducing reflector that has a 55-degree cut-off. Now
you have the Elite engineered superior quality, light engine; producing 600 lumens
(14W) & 900 lumens (16W).
MOUNTING FRAME - Die-formed construction for maximum heat dissipation and
rust protection.
DURABILITY - Die-cast aluminum housing and heat management system are
engineered for extremely long life and service period. Heat sink is attached to top
of housing. The LED light engine is attached to the die-cast heat sink and is easily
replaceable and upgradable. Life tests have shown the Elite light engine output will be
maintained at 70% of initial at 50,000 hours of operation. Our LED driver is rated for
50 to 60 Hz at 120V input, produces less than 20% THD, has a power factor between
0.90 and 1.00 and is thermally protected for additional safety. Elite’s driver is installed
on the junction box cover so it may be serviced from below the ceiling.
RETAINING SPRINGS - Precision tooled springs secure trim to mounting frame,
for effortless and tool-less installation.
REPEATABLE - Repeatability means quality. From our chip selection process, to our
driver, to the thermal management, the MAXILUME LED Module is engineered for
quality. All MAXILUME LED luminaries are rated at 85+ CRI and tested to LM-79
and LM-80 standards by a certified laboratory. California Title-24-2008 and Energy
Star compliance are standard.
DIMMABLE - The MAXILUME LED system is fully dimmable down to 10% of initial
light output with a 0-10 Volt dimmer when ordered with the following options
(DIM10-120, DIM10-277). Fixtures can be shipped with a Lutron Hi-lume A series
Driver which can be dimmed with Lutron Dimming Systems when ordered with the
following options (LUTH-120, LUTH-277). Triac & Electronic Low Voltage dimming
driver also available when ordered with the following options (DIMTR-120). Consult
Factory for details.
MOUNTING BRACKET - Constructed from 16 gauge steel. Can be installed with
3/4” or 1-1/2” lathing channel, 1/2” EMT, or with optional C-channel mounting bars (Part#
BP31) ordered separately. Housing can be adjusted from the inside of the ceiling.
JUNCTION BOX - UL Listed for through-branch circuit wiring, provided with four
½” knockouts, one ¾” knockout and four Romex knockouts with true pry-out slots
and strain clamps. Designed for straight through conduit runs. Driver is installed on
the junction box cover so it may be serviced from below the ceiling.
THERMAL PROTECTION - Standard thermal protection device guards against
improper installation and misuse of insulation material.
OUR WORD - The MAXILUME LED lighting system is warranted for 5 years. As a
system, we stand behind the entire MAXILUME product from housing to bar hangers.
LISTING
c-UL-us / c-ETL-us - listed for Damp location. Feed Through Wiring.
LM79 / LM80
DIMMING INFORMATION
DIMTR (Triac & Electronic Low Voltage Dimming)
DIM10 (0-10V Dimming)
LUTH (Lutron® Hi-lume® Dimming)
HH4SQ-LED
Example: HH4SQ-LED-16W-DIM10-120-30K-LED-4601-CL-WH
TYPE
600 LUMENS
900 LUMENS
HH4SQ-LED
o 14W-DIMTR-120
o 16W-LUTH-120
o 14W-LUTH-120
o 16W-LUTH-277
o 14W-LUTH-277
o 16W-DIM10-120
o 14W-DIM10-120
o 16W-DIM10-277
o 14W-DIM10-277
42
COLOR
o 27K
o 30K
o 35K
o 40K
o 50K
EMERGENCY
o EMG-LED
(Must have
ceiling access for
maintenance)
OPTION
o BP31
(C-CHannel Bar Hanger)
TRIM TYPE
o LED-4601
o LED-4607
WWW.MAXILUME.COM • TEL 1-877-375-5555 • FAX 1-877-375-3333
o LED-4614
o LED-4615
REFLECTOR/ RING FINISH
o CL-WH
o W-WH
o CL-SCH
o MB-WH
o SHZ-SHZ
o WT-WH
o SHZ-WH
ALL PRODUCTS ARE U.S. AND
FOREIGN PATENT PENDING
4” LED SQUARE OPTICS
LED-4601-CL - REFLECTOR
REFLECTOR/ RING FINISH:
CL-WH
CL-SCH
SHZ-WHWT-WH
W-WHSHZ-SHZ
MB-WH
A = 3-1/8”
B = 5-3/4”
C = 4-5/8”
CL
WT
MB
SHZ
W
LED-4607-CL - WALL WASH REFLECTOR WITH LENS
REFLECTOR/ RING FINISH:
CL-WH
CL-SCH
SHZ-WHWT-WH
W-WHSHZ-SHZ
MB-WH
A = 3-1/8”
B = 5-3/4”
C = 4-5/8”
CL
WT
MB
SHZ
W
LED-4614-CL - REFLECTOR WITH FROSTED GLASS LENS
REFLECTOR/ RING FINISH:
CL-WH
CL-SCH
SHZ-WHWT-WH
W-WHSHZ-SHZ
MB-WH
A = 3-1/8”
B = 5-3/4”
C = 4-5/8”
CL
WT
MB
SHZ
W
LED-4615-CL - REFLECTOR WITH TEMPERED GLASS LENS
REFLECTOR/ RING FINISH:
CL-WH
CL-SCH
SHZ-WHWT-WH
W-WHSHZ-SHZ
MB-WH
A = 3-1/8”
B = 5-3/4”
C = 4-5/8”
CL
ALL PRODUCTS ARE U.S. AND
FOREIGN PATENT PENDING
WWW.MAXILUME.COM • TEL 1-877-375-5555 • FAX 1-877-375-3333
WT
MB
SHZ
W
43
HH4SQ-LED-14W-4601-SHZ-SHZ
INPUT WATTS: 14
LUMENS: 580
Zonal Lumens Summary
Candle Power Distribution (Candelas)
Zone
90º
0-20
0-30
0-40
0-60
0-80
0-90
80º
97
70º
194
CRI: +85EFFICACY: 41.42 60º
Lumens
Luminance (Average candela/M2)
%Lamp
138.47
294.80
437.23
556.11
580.21
580.49
%Fixt
23.90
50.80
75.40
95.90
100.00
100.10
23.90
50.80
75.30
95.80
100.00
100.00
Angle
in
Degrees
Average Average Average
0º
45º
90º
45
55
65
75
85
17185
8503
5787
0
0
50º
290
TEST NO.: ELT-261
CCT: 4000K
7602
5082
3405
1866
0
SPACING CRITERIA: 1.24
Lumens Per Zone
9846
9144
4869
2203
367
40º
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30º
387
20º
10º
80%
70% 50% 30% 10%
RC
RW
Cone of Light
22.5
5.6
2.5
12.9’
25.9’
38.8’
16.0
20.0
1.4
0.9
51.7’
64.6’
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
0
1
2
3
4
5
6
7
8
9
10
ROOM CAVITY RATIO
4.0
8.0
12.0
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
119
112
105
98
92
86
81
76
71
67
64
119
109
99
91
83
76
70
65
60
56
52
LUMENS: 220
Candle Power Distribution (Candelas)
Zone
0-20
0-30
0-40
0-60
0-80
0-90
80º
67
116
110
103
96
90
84
79
74
70
66
62
116
107
98
89
82
75
69
64
60
56
52
70º
60º
116
102
89
79
71
64
58
53
48
44
41
111
103
94
86
79
73
68
63
58
54
51
CRI: +85EFFICACY: 20 Lumens
83.33
141.79
178.86
211.19
219.73
219.86
111
101
91
82
74
67
62
57
52
48
45
111
99
87
78
70
63
57
52
48
44
41
%Lamp
%Fixt
38.00
64.60
81.50
96.30
100.20
100.20
37.90
64.50
81.40
96.10
99.90
100.00
Angle
in
Degrees
Average Average Average
0º
45º
90º
45
55
65
75
85
6756
3118
1962
0
0
2751
3062
2995
1851
0
4028
4092
3454
2717
0
40º
268
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30º
10º
20º
RC
RW
Cone of Light
16.39
4.10
1.82
8.9’
17.9’
26.8’
16.0
20.0
1.02
0.66
35.8’
44.7’
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
0
1
2
3
4
5
6
7
8
9
10
ROOM CAVITY RATIO
4.0
8.0
12.0
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
80%
70% 50% 30% 10%
119
113
107
101
95
90
85
81
77
73
70
LUMENS: 459
Candle Power Distribution (Candelas)
90º
80º
78
70º
155
119
107
97
88
81
75
69
64
60
57
53
60º
70%
70% 50% 30% 10%
119
105
93
84
76
70
65
60
56
52
49
RC - Ceiling Cavity Reflectance
HH4SQ-LED-14W-4614-SHZ-SHZ
INPUT WATTS: 14
119
110
101
94
87
81
76
71
67
63
59
117
111
104
99
93
88
84
79
76
72
69
117
108
100
92
86
80
75
70
66
62
59
0-20
0-30
0-40
0-60
0-80
0-90
117
103
92
83
76
70
64
60
56
52
49
111
104
96
90
84
78
73
69
65
61
58
112.07
231.16
339.89
440.77
458.90
459.07
111
102
93
85
79
73
68
63
59
56
53
111
100
90
82
75
69
64
59
56
52
49
24.40
50.40
74.10
96.10
100.00
100.10
%Fixt
24.40
50.40
74.00
96.00
100.00
100.00
Angle
in
Degrees
Average Average Average
0º
45º
90º
45
55
65
75
85
12605
6902
4266
0
0
11634
5006
2648
1285
0
9821
7176
2726
1068
167
40º
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30º
10º
20º
RC
RW
Cone of Light
4.0
8.0
12.0
19.07
4.77
2.12
13.8’
27.7’
41.5’
16.0
20.0
1.19
0.76
55.3’
69.1’
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
ROOM CAVITY RATIO
311
0
1
2
3
4
5
6
7
8
9
10
80%
70% 50% 30% 10%
119
112
105
98
92
86
81
76
71
67
64
119
109
99
91
83
76
70
65
60
56
52
119
106
94
85
76
69
63
58
53
49
46
RC - Ceiling Cavity Reflectance
30%
50% 30% 10%
106
99
91
84
77
71
66
62
57
54
50
106
97
88
80
73
66
61
56
52
48
45
0
5
15
25
35
45
55
65
75
85
90
360
361
360
331
250
125
50
25
0
0
0
10%
50% 30% 10%
106
96
85
77
69
62
57
52
48
44
41
102
95
88
82
75
70
65
60
56
53
49
102
94
86
78
71
65
60
55
51
48
44
102
93
84
75
68
62
56
52
48
44
41
0%
0%
100
91
82
74
66
60
55
50
46
42
39
TEST NO.: ELT-264
SPACING CRITERIA: 0.76
Lumens Per Zone
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
24.26
59.07
58.45
37.07
21.57
10.77
6.40
2.13
0.13
30%
50% 30% 10%
107
100
93
87
81
76
72
68
64
60
57
107
98
91
83
77
72
67
63
59
56
52
Candela Tabulation
0
0
5
15
25
35
45
55
65
75
85
90
10%
50% 30% 10%
107
97
88
80
74
68
63
59
55
52
49
102
97
90
85
80
75
70
66
63
60
57
102
95
88
82
76
71
66
62
58
55
52
102
94
86
79
73
68
63
59
55
52
49
262
266
252
182
101
49
18
8
0
0
0
0%
0%
100
92
85
78
71
66
61
57
54
50
47
119
103
90
80
71
64
58
53
48
44
41
70%
70% 50% 30% 10%
116
110
103
96
90
84
79
74
70
66
62
116
107
98
89
82
75
69
64
60
55
52
116
104
93
84
75
68
62
57
53
49
45
RW - Wall Reflectance
116
102
89
79
71
64
58
52
48
44
41
TEST NO.: ELT-265
CCT: 4000K
Luminance (Average candela/M2)
%Lamp
50º
233
117
105
96
87
80
74
69
64
60
56
53
50%
50% 30% 10%
CRI: +85EFFICACY: 32.78 Lumens
34.80
103.67
156.33
142.43
80.08
38.80
19.59
4.51
0.28
Candela Tabulation
0
RW - Wall Reflectance
Zonal Lumens Summary
Zone
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
CCT: 4000K
Luminance (Average candela/M2)
50º
201
116
104
93
84
76
69
63
57
53
49
45
50%
50% 30% 10%
Lumens
RW - Wall Reflectance
Zonal Lumens Summary
90º
134
119
103
90
80
71
64
58
53
48
44
41
RC - Ceiling Cavity Reflectance
HH4SQ-LED-14W-4607-SHZ-SHZ
INPUT WATTS: 14
119
106
94
85
76
69
63
58
53
49
46
70%
70% 50% 30% 10%
Zone
50%
50% 30% 10%
111
103
94
86
79
73
68
63
58
54
51
111
101
90
82
74
67
62
57
52
48
45
111
99
87
78
70
63
57
52
48
44
41
SPACING CRITERIA: 0.74
Lumens Per Zone
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
29.06
83.01
119.09
108.73
66.74
34.14
15.15
2.98
0.16
30%
50% 30% 10%
106
99
91
84
77
71
66
61
57
53
50
106
97
88
80
73
66
61
56
52
48
45
106
96
85
76
69
62
57
52
48
44
41
Candela Tabulation
0
0
5
15
25
35
45
55
65
75
85
90
10%
50% 30% 10%
102
95
88
81
75
70
65
60
56
53
49
102
94
86
78
71
65
60
55
51
47
44
102
93
84
75
68
62
56
52
47
44
41
305
302
286
242
171
91
40
18
0
0
0
0%
0%
100
91
82
73
66
60
55
50
46
42
39
HH4SQ-LED-16W-4601-SHZ-SHZ
INPUT WATTS: 16.4
LUMENS: 911
Candle Power Distribution (Candelas)
90º
80º
151
70º
302
60º
CRI: +85EFFICACY: 57 Zonal Lumens Summary
Zone
0-20
0-30
0-40
0-60
0-80
0-90
Lumens
221.90
470.38
686.93
871.79
910.53
910.98
Luminance (Average candela/M2)
%Lamp
24.40
51.70
75.50
95.80
100.00
100.10
%Fixt
24.40
51.60
75.40
95.70
100.00
100.00
50º
454
Angle
in
Degrees
Average Average Average
0º
45º
90º
45
55
65
75
85
28465
13795
9647
0
0
15081
8493
5673
3282
0
15960
14875
7641
3447
501
40º
605
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30º
10º
20º
RC
RW
4.0
8.0
12.0
36.7
9.2
4.1
13.2’
26.4’
39.6’
16.0
20.0
2.3
1.5
52.7’
65.9’
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
ROOM CAVITY RATIO
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
0
1
2
3
4
5
6
7
8
9
10
80%
70% 50% 30% 10%
119
112
105
98
92
86
81
76
72
68
64
LUMENS: 372
Candle Power Distribution (Candelas)
90º
80º
107
70º
214
119
106
94
85
76
69
63
58
53
49
46
60º
70%
70% 50% 30% 10%
119
103
90
80
71
64
58
53
49
45
41
RC - Ceiling Cavity Reflectance
HH4SQ-LED-16W-4607-SHZ-SHZ
INPUT WATTS: 16.4
119
109
99
91
83
76
70
65
60
56
53
116
110
103
96
90
85
79
75
70
66
63
116
107
98
89
82
75
70
64
60
56
52
0-20
0-30
0-40
0-60
0-80
0-90
111
103
94
87
80
73
68
63
59
55
51
CRI: +85EFFICACY: 23.25 Lumens
137.38
233.90
294.29
357.24
372.25
372.45
111
101
91
82
74
68
62
57
53
49
45
111
99
87
78
70
63
57
53
48
44
41
36.90
62.90
79.20
96.10
100.10
100.20
%Fixt
36.90
62.80
79.00
95.90
99.90
100.00
Angle
in
Degrees
Average Average Average
0º
45º
90º
45
55
65
75
85
9875
2463
1992
0
0
5260
1997
805
555
0
2720
580
83
75
67
40º
429
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30º
10º
20º
RC
RW
4.0
8.0
12.0
36.7
9.2
4.1
13.2’
26.4’
39.6’
16.0
20.0
2.3
1.5
52.7’
65.9’
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
ROOM CAVITY RATIO
Cone of Light
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
0
1
2
3
4
5
6
7
8
9
10
80%
70% 50% 30% 10%
119
113
106
100
95
89
84
80
76
72
69
LUMENS: 709
Candle Power Distribution (Candelas)
90º
80º
125
70º
250
119
107
96
88
80
74
68
63
59
56
52
60º
70%
70% 50% 30% 10%
119
105
93
83
75
69
63
59
55
51
48
RC - Ceiling Cavity Reflectance
HH4SQ-LED-16W-4614-SHZ-SHZ
INPUT WATTS: 16.4
119
110
101
93
86
80
75
70
66
62
59
116
110
104
98
93
88
83
79
75
71
68
116
108
99
92
85
79
74
69
65
61
58
0-20
0-30
0-40
0-60
0-80
0-90
116
103
92
82
75
69
63
59
55
51
48
111
104
96
89
83
77
72
68
64
60
57
180.76
369.00
531.24
681.18
708.55
708.81
111
102
92
85
78
72
67
62
58
55
52
111
100
90
81
74
68
63
58
54
51
48
Luminance (Average candela/M )
%Lamp
25.50
52.10
75.00
96.20
100.10
100.10
%Fixt
25.50
52.10
74.90
96.10
100.00
100.00
Angle
in
Degrees
Average Average Average
0º
45º
90º
45
55
65
75
85
21309
11607
7297
0
0
17938
8131
4291
2087
0
15485
11184
4078
1559
234
40º
Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
30º
10º
20º
RC
RW
Cone of Light
4.0
8.0
12.0
30.9
7.7
3.4
13.3’
26.5’
39.8’
16.0
20.0
1.9
1.2
53.0’
66.3’
Distance to
Plane
Initial
Footcandle
at Nadir
Beam
diameter
BEAM DIA. MEASURED AT 50% OF NADIR F.C.
ROOM CAVITY RATIO
500
0
1
2
3
4
5
6
7
8
9
10
80%
70% 50% 30% 10%
119
112
105
99
92
87
81
76
72
68
64
119
109
100
91
83
77
71
65
61
57
53
119
106
95
85
77
70
64
58
54
50
46
RC - Ceiling Cavity Reflectance
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
56.21
165.69
248.48
216.55
122.47
62.39
31.49
7.25
0.45
30%
50% 30% 10%
106
99
91
84
77
72
66
62
58
54
50
106
97
88
80
73
67
61
56
52
48
45
106
96
85
77
69
63
57
52
48
44
41
Candela Tabulation
0
0
5
15
25
35
45
55
65
75
85
90
10%
50% 30% 10%
102
95
88
82
75
70
65
60
56
53
50
102
94
86
78
72
66
60
56
51
48
45
102
93
84
75
68
62
57
52
48
44
41
587
588
585
551
419
207
81
42
0
0
0
0%
0%
100
91
82
74
67
60
55
50
46
43
39
TEST NO.: ELT-00251
SPACING CRITERIA: 1.00
Lumens Per Zone
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
39.63
97.75
96.52
60.40
39.67
23.28
11.96
3.04
0.21
30%
50% 30% 10%
107
100
93
86
81
76
71
67
63
59
56
107
98
90
83
76
71
66
62
58
54
51
107
97
88
80
73
67
62
58
54
51
48
Candela Tabulation
0
0
5
15
25
35
45
55
65
75
85
90
10%
50% 30% 10%
102
96
90
84
79
74
69
66
62
59
56
102
95
88
81
75
70
65
61
57
54
51
102
94
86
78
72
67
62
58
54
51
48
428
426
405
313
180
72
14
8
0
0
0
0%
0%
100
92
84
77
71
65
60
56
52
49
46
119
104
91
80
72
64
58
53
49
45
42
70%
70% 50% 30% 10%
116
110
103
97
90
85
80
75
71
67
63
116
107
98
89
82
76
70
65
60
56
53
116
104
93
84
76
69
63
58
54
50
46
RW - Wall Reflectance
TEST NO.: ELT-00252
CCT: 4000K
2
50º
375
116
105
95
87
79
73
68
63
59
55
52
50%
50% 30% 10%
CRI: +85EFFICACY: 44.30 Lumens
Zone
RW - Wall Reflectance
Zonal Lumens Summary
Zone
Lumens Per Zone
CCT: 4000K
Luminance (Average candela/M2)
%Lamp
50º
321
116
102
89
79
71
64
58
53
48
45
41
50%
50% 30% 10%
SPACING CRITERIA: 1.26
RW - Wall Reflectance
Zonal Lumens Summary
Zone
116
104
93
84
76
69
63
58
53
49
46
TEST NO.: ELT-00250
CCT: 4000K
116
102
90
79
71
64
58
53
49
45
42
50%
50% 30% 10%
111
103
94
87
80
74
68
63
59
55
52
111
101
91
82
74
68
62
57
53
49
46
111
99
88
78
70
64
58
53
49
45
42
SPACING CRITERIA: 1.12
Lumens Per Zone
Zone
Lumens
0-10
10-20
20-30
30-40
40-50
50-60
60-70
70-80
80-90
47.03
133.73
188.25
162.23
98.59
51.36
22.80
4.57
0.26
30%
50% 30% 10%
106
99
91
84
78
72
67
62
58
54
51
106
97
88
80
73
67
61
57
52
49
45
106
96
86
77
69
63
57
53
48
45
41
Candela Tabulation
0
0
5
15
25
35
45
55
65
75
85
90
10%
50% 30% 10%
102
96
89
82
76
70
65
61
57
53
50
102
94
86
79
72
66
61
56
52
48
45
102
93
84
76
69
62
57
52
48
45
41
494
491
467
405
291
155
68
31
0
0
0
0%
0%
100
91
82
74
67
61
55
51
47
43
40
Download