FG-110 FF Modbus Gateway and Linking Device for Integrating FOUNDATION™ Fieldbus FG-110 FF allows integrating FOUNDATION Fieldbus (FF) technology into legacy plants and Modbus control systems. It includes a Windows-based FF configuration tool and can be used for implementing state-of-theart information services. AMS Suite FF HSE Ethernet Controller FOUNDATION Fieldbus H1 Field Device Field Device Extending Plants and Controllers by Integrating FF Advantages ▪ Optimally designed for addressing requirements of plant operators and system integrators ▪ Integration of up to four FF H1 segments with up tos 64 field devices into Modbus RTU based legacy plants or into control systems supporting Modbus TCP ▪ Access to process data ▪ Making use of FF advantages like reduced cabling, central field device parameterization, comprehensive diagnosis functionality, or intrinsically safe, fieldbus-powered field devices ▪ Chance for implementing “Control in the Field” by configuring available field devices as control loop without dedicated controller component Cost Savings Through Included Configuration Tool ▪ Delivered together with a Windows-based FF configuration tool ▪ Communication via FF HSE protocol ▪ Complete FF configuration functionality like definition of Function Block linking and scheduling, bus parameter settings and field device parameterization ▪ Usage of registered standard Device Description files, as available from field device manufacturers and the FieldComm Group ▪ Integrated web server for defining mapping of FF functions to Modbus registers or for monitoring process values Access Point for Using Additional Functionality in FF Segment ▪ Usage as key component for implementing additional automation functionality in FF section of the plant ▪ Integration of asset management systems and frame applications Technical Data Communication Physical Properties Product Certifications FOUNDATION Fieldbus H1 Transfer Rate: LED Indicators: Connectors: 31.25 Kbit/s Power on, activity LED per segment 3-position screw connection, galvanically isolated FOUNDATION Fieldbus HSE 100BASE-TX/10BASE-T, automatic recognition Connector: RJ45 Modbus TCP, Modbus RTU Assign registers to process values using TAG parameter of Analog Input Function Block Serial Interface EIA-232 9-pin D-sub female connector Transfer Rate: 1.2 Kbit/s … 115.2 Kbit/s Galvanically isolated Power Supply 24 VDC (±20 %), typically 200 mA No power supply to FF H1 segments through FG-110 FF Operating / Storage Temperature 0 °C … +70 °C / -20 °C … +70 °C Dimensions (W x H x D) 47 mm x 131 mm x 111 mm (1.9” x 5.2” x 4.4”) Relative Humidity 0 % ... 95 %, non-condensing Mounting DIN rail, 35 mm Degree of Protection IP20 CE EN61000-6-2, EN61000-6-4, EN55022 Limit Class A Electro Magnetic Compatibility (EMC) FCC Part 15 Subpart B Class C, VCCI Class 2 Information Technology Equipment 2002 Shock/Vibration DIN IEC68 Part 2 Hazardous Location Certifications UL508, CSA C22.2 No. 14-M95 Industrial Control Equipment Scope of Delivery Hardware FG-110 FF Software Windows-based FF configuration tool, web server for Modbus mapping configuration Documentation User’s manual Order Numbers GLA-YK-020110 FG-110 FF Technical changes reserved © Softing Industrial Automation GmbH, FG110_FF_D_EN_160601_200, June 2016 Options for Building Customer-Specific Fieldbus Interface Module Based on FG-110 FF AHA-YK-020111 FG-110 FF Option: IP65 Housing Plus Assembling Services APA-YK-020111 FG-110 FF Option: Power Conditioner GPA-YK-020111 FG-110 FF Option: EIA-232/EIA-485 Converter AAA-YK-020101 FG-110 FF Option: CM 20 Conduit Adapter (Only one adapter can be selected) AAA-YK-020102 FG-110 FF Option: PG 13.5 Conduit Adapter (Only one adapter can be selected) AAA-YK-020103 FG-110 FF Option: 3/4“ NPT Conduit Adapter (Only one adapter can be selected) AAA-YK-020104 FG-110 FF Option: 1/2“ NPT Conduit Adapter (Only one adapter can be selected) Additional Products and Services OPC-MODB-TCP Modbus TCP OPC-Server Your local Softing Contact Softing Industrial Automation GmbH Richard-Reitzner-Allee 6 85540 Haar / Germany Tel.: +49 89 456 56-340 Fax: +49 89 456 56-488 info.automation@softing.com http://industrial.softing.com Softing Industrial Automation GmbH Äußere Sulzbacher Straße 159-161 90491 Nürnberg / Germany Tel.: +49 911 544 27-0 Fax: +49 911 544 27-27 info.automation@softing.com http://industrial.softing.com Buxbaum Automation GmbH Thomas-Alva-Edison-Straße 1 7000 Eisenstadt / Austria Tel.: +43 2682 704 560 Fax: +43 2682 205 77 00-5610 office@myautomation.at http://myautomation.at Softing Inc. US Headquarter 7209 Chapman Highway Knoxville, TN 37920 / USA Tel.: +1 865 251 52 52 Fax: +1 865 579 47 40 info@softing.us http://www.softing.us Softing Inc. US Sales Office 29 Water Street, Suite 301 Newburyport, MA 01950 / USA Tel.: +1 978 499 96 50 Fax: +1 978 499 96 54 info@softing.us http://www.softing.us Softing Italia Srl Via Padre Massimiliano Kolbe, 6 20090 Cesano Boscone (MI) / Italy Tel.: +39 02 450 51 71 Fax: +39 02 450 41 41 info@softingitalia.it http://softingitalia.it