www.mars-energo.com Meter Test Systems Transformer Test Sets Power Quality Analyzers Digital Substation Solutions 1 Meter Test Systems MTS ME 3.1KM Multipurpose Test System (stationary) The MTS ME 3.1K is meant for conducting adjustment and accuracy tests of service-class or referenceclass measuring instruments of electric quantities. Supplied as typical equipment for test labs. The implied use is testing and adjustment of referenceclass or service-class instruments involved in power quality measurements. The new functions implemented in this version, namely, generation and measurement of 50 harmonics including interharmonics (0.5th, 1.5th, 2.5th...50.5th) make it possible to test instruments measuring power quality (see p. 5 for details). Basic delivery package: Energomonitor 3.1KM reference-class meter; Energoforma 3.1 Programmable waveform generator; current amplifier (3 ps.); voltage amplifier (1 p.); switchgear unit; meter test accessory kit; Energoform software, Energomonitoring software; USB to 4COM adapter. MTS ME 3.1KM-S-05 is supplied with Energomonitor 3.1KM-S-05, accuracy class 0.05 MTS ME 3.1KM-S-02 is supplied with Energomonitor 3.1KM-S-02, accuracy class 0.02 Accessories: CVFC Current/Voltage-to-Frequency Converter, accuracy class 0.02 SMCD Shunt Meter Calibration Device (up to 3 meters) Suspension rack for one three-phase meter for three three-phase meters 2 Precision-turns coils for testing clamp-on instruments: 100-turns coil 20-turns coil 10-turns coil DCA Amplifier of DC voltage and current IDV-3.1 Inductive divider of voltage Mars-Energo Version 01.08.2015 www.mars-energo.com Meter Test Systems MTS ME 3.3 Mobile Test System for electric energy meters The MTS ME 3.3 is meant for testing serviceclass or reference-class measuring instruments commercially used in the power industry. On-site or in-lab tests of instruments (including electric energy meters) can be conducted in automated mode. “Energoform” software Energoforma 3.3 MTS ME 3.3Т1-P-10 MTS ME 3.1КМ-P-05 MTS ME 3.1КМ-P-02 (accuracy class 0.1) (accuracy class 0.05) (accuracy class 0.02) Purpose for testing the instruments of accuracy classes below 0.5S or less accurate 0.2S or less accurate 0.05 or less accurate Device under test Delivery package Energomonitor 3.3Т1 supplied as “Special Plus” set (described on p. 12) Energomonitor 3.1КM-P-05 Energomonitor 3.1КM-P-02 Supplied complete with power cord, PC connection cable, meter test kit, PC-oriented software Energoforma 3.3 Programmable three-phase source of current and voltage (portable design, 7.5А; 380V), complete with Energoform software or Energomonitor 3.3T1, accuracy class 0.1 Energomonitor 3.1KM accuracy class 0.05; 0.02 Energoforma 3.3 Programmable three-phase source of current and voltage Designed to create three-phase or single-phase system of currents and voltages, as specified by programmable digital model of the signal. Range of output voltage setting per each phase of: voltage................................................. 6 to 268 V with 0.01 increments. current............................................ 0.002 to 7.7А with 0.0001 increments. The new functions implemented in this version, namely, generation and measurement of 50 harmonics including interharmonics (0.5th, 1.5th, 2.5th....50.5th) make it possible to test instruments measuring power quality. Energoforma 3.3-100 Programmable three-phase source of current and voltage The range of output current setting per each phase is extended, now it is specified as 2 mA to 100 А. Mars-Energo 3 Meter Test Systems Energomonitor 3.1KM Multifunctional reference standard Introduced for testing/adjustment of referenceclass or service-class instruments that measure electric quantities and power quality parameters. Energomonitor 3.1K meets the needs of large-scale enterprises offering metrological services, electricity companies, and Centers for standardization, metrology and certification. Portable design (IP51 dust-tight enclosure) Energomonitor 3.1KM-P-02, accuracy class 0.02 Desktop design Available as part of MTS ME 3.1KM test system Energomonitor 3.1KM-P-05, accuracy class 0.05 Energomonitor 3.1KM-S, accuracy class 0.02; 0.05 Basic delivery package: Energomonitor 3.1KM instrument; meter test kit (three devices) including photoelectric heads and fixtures for automatic scanning of disk mark passages or LED flashes; Energoform software, connection cables. Specifications Voltage range 0.1 to 960 V (measurement ranges with Unom = 1, 2, 5, 10, 30, 60, 120, 240, 480 and 800 V) Current range 0.005 to 120 A (measurement ranges with Inom = 0.05, 0.1, 0.25, 0.5, 1, 2.5, 5, 10, 25, 50 and 100 A) Impedance of voltage measurement circuits 1 MOhm for Unom = 30, 60, 120, 240, 480 and 800 V; 176 kOhm for Unom = 1, 2, 5 and 10 V Input current scaling converters - Built-in AC Current Transformers Options: - Built-in AC and DC Current Transformers (up to 100 A); - Current clamps 10, 100, 1000, 30/300/3000A; - CT Calibration Switch (provides correct and safe connections to CT under test) Testing of meters Built-in divider of input and out frequencies makes it possible to test reference-class meters with meter constants varying over a wide range Power quality measurements IEC 61000-4-30:2008 and IEC 61000-4-7:2002 compliant power quality parameters are measured and displayed, including: a) RMS of 50 harmonics of current and voltage; b) RMS of 51 interharmonics of current and voltage (0.5th, 1.5th, 2.5th...50.5th) c) Overdeviation and underdeviation of voltage, frequency deviation Optional functions Testing of current and voltage instrument transformers Peak/Amplitude voltmeter Interfaces RS-232 and USB 4 Mars-Energo www.mars-energo.com Meter Test Systems Energomonitor 3.3T1-C Portable meter of reference-class Supports calibration of: electric energy meters of 0.5S accuracy class; class 0.5 or less accurate measuring instruments; class 0.2 or less accurate instrument transformers of voltage or current; peak voltmeters. Additional measurements include three-phase unsymmetry, power factor and frequency parameters. Complete set as per option* Current Transformer Block Current clamps (input converters), 3 ps. (CTB) 10А 100А 100/1000А 5А 50А PF** More auxiliary devices Current measurement ranges Energomonitor 3.3T1-C applicable for testing Class 0.5 or less accurate meters or other instruments*** 50mА÷15А; + + + 250mА÷75А Energomonitor 3.3T1-C applicable for testing meters or other instruments without breaking into current circuits + + + + + + 500mА÷15А 5÷150А 5÷1500А + Energomonitor 3.3T1-C applicable for testing Class 0.5 or less accurate meters or other instruments*** and performance testing of meters without breaking into current circuits 50mА÷15А; + + 500mА÷15А 50mА÷15А; + + + 5÷150А 50mА÷15А; + + + 5÷1500А Energomonitor 3.3T1-C applicable (as a comparator) for testing Class 0.2 or less accurate instrument transformers of current or voltage + * Energomonitor 3.3T1-C delivery package can be tailored to include different types of current clamps or CTBs. ** PF facilitates meter testing by generating pulses either automatically (as a repeater of the pulses coming from the meter), or in respond to operator’s stroke of a button. *** Test system shall involve three-phase current/voltage waveform generator Energoforma 3.3. Optional meter test kit includes photoelectric heads and fixtures attached to meters under test. They generate indicator pulses by scanning disk mark passages (SH-I) or LED flashes (SH-E). Testing of current instrument transformers Testing of electric energy meters Inspection of secondary circuits Calibration of 0.5S meters (direct measurements with 5 А or 50 А CTB) CTCS (Current Transformer Calibration Switch) SH-I, SH-E (photoelectric scanning heads for testing electronic and induction meters) CTB (Current Transformer Block) TBMD (Transformer Burden Measuring Device) Performance testing (without breaking into current circuits) Clip-on CTs 10 A Mars-Energo 5 Meter Test Systems RS series Current shunts (reference-class, reactance-free) Specifications TCR.......................................................2.0 · 10–6 K–1; Permissible value of basic resistance error..............................±0.005%; Permissible value of phase error (absolute)............................. ±10μrad; Nominal AC frequency..................................... 50Hz. The shunts are supplied calibrated, with Certificate of calibration issued by D.I. Mendeleev Institute for Metrology (VNIIM, Saint-Petersburg, Russia). The following records are included in the Certificate: nominal resistance, as measured in normal conditions or at 0 ...100 kHz frequency; TCR; the effect of spontaneous heating at the currents of 3.5A; 5A and 7A; frequency responses, as compared against standard shunt. PCS-ME-1.0 High Accuracy Power Calibration System (conventional) By introducing the PCS-ME-1.0, Mars-Energo have made new step in development of multipurpose test systems and reference standards. Just as MTS ME 3.1KM, new product is meant for testing/adjustment of reference-class or service-class instruments that measure electric quantities and power quality parameters. A feature of the PSC-ME-1.0 is the use of newgeneration products. As latest reference standards and instruments, they provide for: reducing by half the error intrinsic in measurement of electric quantities; extending the functionality of the equipment, which makes it applicable to testing/adjustment of up-to-date measuring instruments for AC and DC determinations; operating in extended frequency range (0 to 5kHz). Basic specifications for PCS-ME-1.0: Parameter Measurement uncertainty Current 0.01–50А 0.004% Voltage 0.1–600V 0.003% Active power (reactive power) PF = 1 0.003% (0.005%) PF = 0.5 0.006% Angle between current and voltage 1st harmonics –180º...+180° 0.0011° at 50Hz 6 Mars-Energo RS-1.0 RS-2.5 1.0А 2.5А 1.0 Ohm 0.4 Ohm RS-5.0 RS-10.0 Nominal current 5.0А 10.0А Nominal resistance 0.2 Ohm 0.1 Ohm www.mars-energo.com 2 Transformer Test Sets HML High-voltage Mobile Lab operating within the ranges of 6 to 330kV; 5kA; 30kA Applicable to tests of instrument transformers (VTs rated 6 to 330kV or CTs rated 5kA or 30kA), as well as comprehensive tests of metering stations. HMLs for the range of 330 to 750kV can be supplied to order. Subset “Multipurpose” 6; 10; 15; 35kV; 5kA Subset “Broadband 110kV” 6; 10; 15; 35; 110kV; 5kA Subset “Broadband 220kV” 6; 10; 15; 35; 110; 220kV; 5kA Subset «Broadband 330kV» 6; 10; 15; 35; 110; 220; 330kV; 5kA Delivery package Subset for current transformer tests within the range of up to 5kA Subset for voltage transformer tests based on the use of Energomonitor 3.3T1 VTs 6; 10; 15; 35kV VTs 6; 10; 15; 35; 110kV VTs 6; 10; 15; 35; 110; 220kV VTs 6; 10; 15; 35; 110; 220; 330kV Subset for comprehensive tests of metering stations Documents on operating techniques (tests, certificates, commissioning) HML “Electrical Lab” – adaptation of light commercial vehicles from Ford, Volkswagen or other (at customer option) HTCS-3-10, HTCS-3-35 HSCS-1-220 Mars-Energo 7 Transformer Test Sets HSCS-1 HTCS-3-10, HTCS-3-35 High-voltage Single-phase Calibration Set High-voltage Three-phase Calibration Sets Introduced for: on-site test/adjustment of Class 0.2 (or less accurate) single-phase instrument voltage transformers (VTs); measurements of VT load power; measurements of basic power quality parameters. Provides for test/adjustment of Class 0.2 (or less accurate) single-phase and three-phase instrument voltage transformers (VTs). Patent N 67285 Patent N 67285 Delivery package includes: Energomonitor 3.3T1 supplied as comparator complete with VTCS; capacitive high-voltage transducer (CHVT series); two burden boxes, each rated 100/√3V, 200VA; one burden box rated 100/√3V, 80VA; single-phase variable-ratio transformer unit (220kV; 330kV); console unit CU-110/220/330; HTB-100 High-voltage Test Bench (not required for 220kV or 330kV applications); complete set of cables; software. Delivery package includes: three-phase HTCS-3-10 or HTCS-3-35 console unit; three-phase variable-ratio transformer unit; loading voltage transformer unit (LVT-10 or LVT-35) (3 ps.) capacitive high-voltage transducers (CHVT-10-2 or CHVT-35-2), each complete with its instrument amplifier of voltage (IAV); Energomonitor 3.3T1 supplied as comparator complete with VTCS; four МР 3025 burden boxes for VT tests software. HSCS-1-110 test set for 110kV voltage transformers HSCS-1-220 test set for 110, 220kV voltage transformers HSCS-1-330 test set for 110, 220, 330kV voltage transformers HTCS-3-10 test set for 6; 10kV voltage transformers HTCS-3-35 test set for 15; 35kV voltage transformers Transformer of NAMI-35 series being calibrated with EmCalibrTrans software (the procedure is completed by producing test report) EmCalibrTrans software 8 Mars-Energo www.mars-energo.com Transformer Test Sets Capacitive High-Voltage Transducers (CHVT series) Voltage measurement error Model CHVT-10 CHVT-10-2* CHVT-35 CHVT-35-2* CHVT-110 CHVT-220 CHVT-330 (HIC stands for High-voltage Insulating Cable) * + + + + + + + + + + + + + + Differential circuitry supports testing of 3-phase VTs. Instrument-class High-voltage Capacitors (IHC series: 10, 35, 110, 220kV) IHC-10 IHC-35 IHC-110 IHC-220 IHC-330 500 mm 1200 mm Designed to fit various measurement equipment, such as VT testers, voltage dividers, testers of highvoltage insulation (that can determine capacitance and tangent of loss angle) and to calibrate VT test systems of 0.2 accuracy class or less accurate. IAV-35 IAV-110 IAV-220 Patent N 118069 IAV ±0.05% 250 mm HIC ±0.1% Optional Instrument Amplifier of Voltage (IAV) VA 3.1 AC/DC Peak voltmeter Designed specifically for high voltage labs where the ultimate accuracy of measurements is required. Accuracy class 0.05 (0.02 – subject to special order). VA 3.1 is meant for measurements of amplitude and peak values, as applied to AC voltages of up to 500Hz frequency, across its three channels including the differential channel, for measurements of DC voltages, for testing/adjustment of 0.02 accuracy class (or less accurate) peak voltmeters and for recording pulse voltage oscillograms. Together with a high-range DC voltage source, VA 3.1 can be used as part of a reference system meant for dissemination of DC voltage unit to working measurement standards in the ranges of up to 100, 200 and 500 kV. Mars-Energo 9 Transformer Test Sets Current transformer test set (range 5A to 5000A) Supports current transformer tests conducted in compliance with national regulations in force. The test set includes: Instrument current transformers (reference-class, portable design, PCTI series): PCTI-100/5, rated at 5–100А; PCTI-5000/5, rated at 100–5000А. Accuracy class 0.05. Energomonitor 3.3T1-C supplied as comparator complete with CTCS (1A and 5А) IT5000 Adjustable current source operating within the range of up to 6000A МР 3027 Burden box (1A and 5А) EmCalibrTrans software (used to handle test logs and generate test reports) Supports current transformer tests conducted in compliance with national regulations in force and МI 3123–2008 procedure. The test set includes: Energomonitor 3.3T1-C supplied as comparator complete with CTCS (1A and 5А) and Current Transformer Block CTB 0.5A Class 0.05 reference current transformer PCTI-5000/5 rated at 100–5000А IT5000 Adjustable current source operating within the range of up to 6000A МР 3027 Burden box (1A and 5А) 10 Mars-Energo Patent N 87539 Current transformer test set (range 6kA to 30kA, indirect method) CT VCC Converter (converts parameters of CT’s voltage-current curve) and dedicated software Delta-T (automatic calculation of CT error and analysing of test results) Generation of test reports with EmCalibrTrans or Delta-T software www.mars-energo.com 3 Digital Substation Solutions Energomonitor 61850 Reference instrument for calibration of electronic current/voltage analogue and digital instrument transformers and Merging Units General Measurement of ratio and angular errors of current and voltage scaling converters (electronic instrument voltage and current transformers) with analogue outputs or digital outputs per IEC 61850-9-2LE; Determining metrological parameters of Merging Units; Measurement of current- and voltage-related quantities with further conversion into IEC 61850-9-2 compliant digital data streams. Components 4 multi-range input current converters; 4 multi-range input voltage converters; 8-channel ADC; Control unit based on built-in single-board computer; Synchronization unit; Power supply module; External tablet PC. Metrological data Measurement error Measurement range Limits of permissible measurement error Notes VT ratio error ±19.99 % absolute ±0.02 % 0.2Unom ≤ U ≤ 1.2Unom; VT angle error ±180° absolute ±1.0' CT ratio error ±19.99 % absolute ±0.02 % CT angle error ±180° absolute ±1.0' f = (fnom ± 1) Hz 0.01Inom ≤ I ≤ 1.2Inom; f = (fnom ± 1) Hz Unom – nominal secondary voltage of the VT under test (100/√3 or 100 V); Inom – nominal secondary current of the CT under test (1 or 5 A); fnom – nominal frequency of the CT or VT under test (50 or 60 Hz). Mars-Energo 11 Digital Substation Solutions KSP-61850 Test Set for testing of electronic voltage and current transformers Purpose KSP-61850 is meant for testing and calibration of electronic transformers designed in conformity with IEC 60044-7-2010 and IEC 60044-8-2010 standards. The purpose of KSP-61850 is to convert (considering scaling factors), measure and compare signals (including IEC 61850-9-2LE signals) from analogue or digital outputs of electronic current (up to 5 kA) and voltage (up to 220, 330 kV) transformers. Components 1. Equipment for testing voltage and current transformers - High-Voltage module High Voltage Source Reference Voltage Transducer CHVT-220 (accuracy 0.05) or Reference Voltage Transformer from EPRO (accuracy 0.01) 2. Equipment for testing voltage and current transformers - Low-Voltage module For laboratory use: single-phase Digital Calibration System DCS ME 61850 (vectorized quantities, comparison principle); accuracy class 0.02, or For on-site use: portable Energomonitor 61850 (8-channel; multi-functional); accuracy class 0.05. 3. Equipment for testing current transformers High-Voltage module Source of test current Reference current transformer PCTI (accuracy 0.05) or reference current transformer from EPRO (accuracy 0.01) 12 Mars-Energo www.mars-energo.com Power Quality Analyzers 4 Instrument Converter Marsen-PQP Marsen-PQP Instrument Converter is a power quality recorder and analyzer. Purpose: Measurement and monitoring of power quality parameters specified in IEC 61000-4-30 and IEC 61000-4-7 standards with further transfer of measurement results to a PC (power quality test reports according to EN 50160); Measurement and monitoring of basic power quality parameters (PQP); Measurement and monitoring of basic electrical network parameters. Field of application: In power quality monitoring and control systems: permanent recording of power quality parameters and events on every cycle (can be installed at electrical substations of any voltage rating); Monitoring of power consumption characteristics and power related parameter sat “power-to-consumer” distribution points. Basic characteristics: Input: Three-phase AC voltage (50 Hz); Un = 57 (100) V or Un = 220 (380) V; AC current (50 Hz); In = 1 A or In = 5 A (4 channels). Interface - Ethernet 100 Mb/s. Data exchange protocols: РТР – (synchronization to UTC); WEB Interface – (configuring; dataprocessing and analysis; generating test reports); IEC 60870-5-104; Modbus TCP. Power supply (at customer's option): 100..240 V (50 Hz); DC 18...36 V; Ethernet (PoE). Mars-Energo 13 Power Quality Analyzers PQP-A Energotester Instrument for electric and PQ (class A) measurements Purpose Designed to measure and log power quality parameters as defined by IEC 61000-4-30 (class A) Measured parameters Frequency Frequency deviation AC frequency Voltage Steady-state voltage deviation (underdeviation and overdeviation) Negative sequence and zero sequence voltage components Harmonic composition - THD and nth harmonic ratios (up to 50) Interharmonics Flicker long-term and short-term perceptibility DC voltage Events Duration and residual voltage of a voltage dip Duration and maximum swell voltage magnitude of a voltage swell Duration of a voltage interruption Current RMS of AC current and RMS of 1st current harmonic Positive, zero and negative sequence current Angles Phase angle between 1st harmonics of phase voltages and currents Power and Energy Active, reactive and apparent power Power factor Active and reactive energy Active power (positive, negative and zero sequence components) Basic delivery package* (no current or power measurement capabilities): Instrument complete with Power supply unit Rechargeable batteries Test probes PC connection cable, USB interface Portable containers: one bag, one case PC-oriented software of Energomonitoring family GPS-antenna * Version for class S measurements is available. Application notes Measured parameters 14 Can be applied for Power quality parameters (underand overdeviation of voltage, frequency deviation as defined by IEC 61000-4-30, class A «AC power certification»; measurement results can be used in arbitration as a proof of compliance/non-compliance of AC power to the quality declared by a distributor Accidental events: •voltage interruptions •dips, •swells Detection and analysis of emergency situations Short circuits, power cutoffs, distorting loads, overloads etc. Active power of: •harmonics •negative sequence •zero sequence Detecting sources of distortion and calculation of respective energy losses Used to pinpoint power quality problems - track down root causes of distortion (particular circuit components, devices etc.). This helps to work out protection techniques, e.g. to determine a new place for the distorting component in the circuit or calculate parameters for protection filters •Voltage (0.1–600V), •Current (0.01–3500A), •Active, reactive and apparent power •Power factor Energy savings Logging of these values make it possible to build detailed graphs of consumer demand (consumer load graphs) and achieve energy savings by discovering energy wastes and, e.g., deciding on measures for reactive load compensation Energy efficiency classification Logging of power consumption data makes it possible to classify appliances with respect to power consumed in various operation modes Active (kWh) and reactive (kVarh) energy (export and import), phase and phase-to-phase angles for currents and voltages, vector diagram Inspection of meter reading and billing systems Check of meter’s connectivity and performance; testing of AMR systems Active energy (kWh) (measured synchronously by two class A instruments) Determining energy losses in power transmission lines Makes it possible to localize points with limits-exceeding energy losses (focusing on either technical or commecial aspect) Mars-Energo www.mars-energo.com Power Quality Analyzers EmWorkNet software is used to display data collected by PQP-A Energotester, view graphs and generate reports as per national and IEC standards in force. Specifications Measuring category: IEC 61010-1, 600V, cat. III Operating temperature: –20 to +55 °С Time of continuous operation when powered from internal batteries: at least 2 hours Protection provided by the enclosure: IP 51 Capacity of internal memory: 512 MB ADC sampling rate: 40 kHz Max. error of synchronization against UTC: ±5 ms Dimensions (L × W × H): 250 × 120 × 80 mm Weight: no more than 1.0 kg Power supply voltage: 80 to 240V Complete set as per option «10А» set «10А+1000А» set «10А+3000А» set Current measurement ranges: 10mA÷15A, In = 10А Current measurement ranges: 10mA÷15A, In = 10А; 10÷1500A, In = 1000A Current measurement ranges: 10mA÷15A, In = 10A; 0.3÷45A, In = 30A; 3÷450A, In = 300A; 30÷4500A, In = 3000A Basic set Instrument GPS antenna Leather bag Test leads Power supply unit (Uout = 12.6V, Iout = 0.8A) PC-oriented software of Energomonitoring family Current clamps 10A, accuracy class 1.0 Current clamps 10A, accuracy class 1.0 Optional current sensors: Current clamps 10A, accuracy class 0.2 Current clamps 10A, accuracy class 1.0 Current clamps 1000A, accuracy class 0.5 Flexible current sensors 30 / 300 / 3000 A ME FLEX 3003, accuracy class 2.0 Block of current transformers, accuracy class 0.1 Mars-Energo 15 www.mars-energo.com Russia Mars-Energo Established in 1991 Mars-Energo specializes in design, manufacturing and service of high accuracy metrological equipment and meter test systems for power industry applications. The company takes an active part in developing and maintaining of the aggregate of measurement standards on national and CIS scales. Mars-Energo’s reference instruments provide calibration of the wide range of measuring instruments for quality control and electricity metering: instrument-class transformers, power quality analyzers, electric energy meters including measuring instruments for digital substations and Smart Grids. V.O. 13 Line, 6-8 Saint-Petersburg, Russia, 199034 E-mail: mail@mars-energo.ru www.mars-energo.com Sales E-mail: mars@mars-energo.com korneeva@mars-energo.ru Tel./Fax: +7 812 331-87-36 +7 812 327-21-11 Estonia OU “ESME” Kalda tu 9, Narva, Estonia, 20103 E-mail: mail@esme.ee Tel.: +372 568-099-99 www.esme.ee Quality management system complies with ISO 9001:2008