Instrumentation Robust, educational and industrial measuring equipment for electrical laboratories and educational facilities. Multimeter Multimeter Lucas Nülle GmbH Page 1/35 www.lucas-nuelle.com List of articles: Pos. Product name Bestell-Nr. 1 Analog/digital multimeter, wattmeter + power-factor meter incl. software CO5127-1Z Anz. 1 The areas of electrical machines, power electronics and drive technology pose particular problems for measuring instruments. In addition to high-performance overload protection, the acquisition of measurement values must be performed accurately independently of the curve's shape. The universal measuring device has been designed particularly to satisfy these requirements. It can simultaneously replace as many as four different measuring instruments – constituting a current/voltmeter, power and phaseangle meter all in one. The graphic display allows for both student as well demonstration experiments. The VI Starter software included allows for visualisation of measurements on a PC. Simultaneous, measurement of voltage and current independent of the curve shape (max. 600 V, 20 A) (measurement of clocked voltages) Calculation of active, apparent and reactive power as well as the power factor Measurement of the total rms (RMS-AC+DC), AC rms (RMSAC) and arithmetic mean (AV-AC+DC) Impervious to electrical damage up to 20 A/600 V Large-scale, high-contrast background-illuminated graphic display (5.7") Large-scale display or display of up to 4 measurement values Digital or pseudo-analog display USB interface Internal resistance: current path 10 mΩ, voltage path 10 MΩ Voltage ranges: 30, 300, 600 V Current ranges: 1, 10, 20 A Measurement accuracy: 2% Automatic or manual measurement range selection Demonstration test instrument for measuring properties of the electricity supply Operating voltage: 230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxBxT) Weight: 2kg The VI Starter software allows all the measurements to be displayed on the PC. Up to 17 different displays can be opened. Oscilloscope display of voltage, current and power Consumption meter to display power consumed and output Data logger for 14 different variables Data export for data logger Characteristic recorder Labview driver and supplied examples 32-bit version for Windows Lucas Nülle GmbH Page 2/35 www.lucas-nuelle.com 2 Three-phase Smart Meter CO5127-1Y 1 The three-phase meter allows for measurement of all the relevant parameters for a three-phase supply network. It can measure single or double phase circuits as well as three-phase. Display and operation are controlled via a menu shown on the liquid crystal display or accessed via the integrated Ethernet port. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (Smart Grid). The “Smart Meter” acts as a digital electricity meter at the end points of the mains network to measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Measurement of three-phase current or voltage 3x400V/5A Measurement of phase voltages, linked voltages, current Determination of apparent active and reactive power Determination of apparent active and reactive work Determination of frequency and distortion factors for current and voltage Large, high-contrast graphic display with backlighting Digital I/O for assignment of custom functions Ethernet port Demonstration meter for mains operation max. measurement values: Voltage P-P: 690 V Current: 5A Measurement accuracy: Voltages 0,3% Currents 0,2% Apparent power 0,5% Active power 0,5% Reactiv power 2% Active energy Klasse 0,5 Reactive energy Klasse 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxBxT) Weight: 2kg Lucas Nülle GmbH Page 3/35 www.lucas-nuelle.com 3 Three-phase power quality meter with display and long-term memory CO5127-1S 1 The three-phase measuring instrument permits the measurement and display of relevant power network parameters. It is able to measure single, two-phase or three-phase measurements. The display and operation is carried out by means of menu navigation with an LC display or the integrated Ethernet interface. The optional SCADA software provides for the display of all measurements and allows the implementation and analysis of intelligent networks (smart grids). The “smart meter” acts as a digital electricity meter where end customers are connected to the grid in orderto measure electricity consumption and can be used to turn consumers on or off depending on the circumstances. Three-phase measurement of current and voltage 3x400V/5A Measurement of phase voltages, line-to-line voltages and currents Determination of the apparent, active and reactive power Determination of active, reactive and apparent work Determination of the frequency and distortion factors for current and voltage Detection of harmonic oscillations and neutral conductor current in the electricity supply Pulse measurement Peak and mean value detection Event logging Real-time clock Large-scale, contrast-rich graphic display with background illumination Display in tables, diagrams and vector diagrams 2 Digital inputs and outputs for free configuration including functions Ethernet interface Menu navigation in German/English/ French/Spanish/Italian/Portuguese/Turkish/ Chinese/Russian/Polish Demonstration measuring instrument for making measurements on the electricity supply grid Max. measurement values: Voltage P-P: 690 V Current: 5 A Fault tolerances: Voltage 0.2% Current 0.2% Apparent power 0.5% Active power 0.2% Reactive power 1% Active energy Class 0.2 Reactive energy Class 2 Operating voltage: 110V-230V, 50/60Hz Dimensions: 297 x 228 x 140mm (HxWxD) Weight: 2kg Lucas Nülle GmbH Page 4/35 www.lucas-nuelle.com 4 Analog multimeter 0...500V (DC1000V)/5A, 1-500kOhm LM1101 1 LM1121 1 Analog multimeter for the measurement of DC and AC voltages, DC and AC currents, resistance and DB values and impedances. Including overload protected movement, safety sockets. DC voltage ranges: 0...1.5V, 0...0.5V; 0...1.5V; 5V, 15V, 50V, 500V, 0...1000V AC voltage ranges: 0...1.5V, 5V, 15V, 50V, 150V, 500V DC current ranges: 0...50µA; 0...0.5mA; 5mA, 50mA; 500mA; 5A AC current ranges: 0...0.5mA; 5mA; 50mA; 500mA; 5A Resistance: 1ohm...1Mohm (4 ranges) Internal resistance: DC: Ri=20kOhm/V AC: Ri= 4kOhm/V Level: -15...+56dB (6 ranges) Power supply: 1.5V mignon battery, (type IEC R 6) Inputs/outputs: 4mm safety sockets Dimensions: 92 x 126 x 45mm (WxHxD) Weight: 0.25kg 5 Analog multimeter AC 300V/3A, DC 300V/10A Alternating voltage ranges: 10/30/100/300V Direct voltage ranges: 100mV/1/3/10/30/100 /300V Alternating current ranges: 3/30/300mA /3/10A Direct current ranges: 50uA/ 3/30/300mA / 3 A Resistance ranges: 1/10/100Ohm Accuracy class: 2.5 Ri = 20 kOhm/V DC6.66kOhm/V AC Weight: 0.3kg Lucas Nülle GmbH Page 5/35 www.lucas-nuelle.com 6 Analog multimeter, 600 V/10 A/2 MOhm LM1123 1 LM2322 1 Alternating voltage ranges: 10/50/250/600V Direct voltage ranges: 2.5/10/50/250/600V Alternating current ranges: 10/250/500mA/10A Direct current ranges: 10/250/500mA/10A Resistance ranges: 0.2/2/20/200 kOhm/2MOhm Accuracy class: 3% Ri = 10MOhm/DC, 1MOhm/AC Weight: 0.5kg 7 MetraHit WORLD digital multimeter with IR-Interface, TRMS Universal laboratory multimeter and temperature measuring instrument with patented automatic socket disabling and IR data interface, to fulfill the highest demands placed on measurement functions and accuracy. Resolution: ±31.000 digits Measurement functions voltage and current: 600mV 600VDC, 600 mV - 600V AC; 60mA - 10A DC; 60 mA - 10AAC Resistance ranges: 600Ohm - 40Mohms Special ranges: °C Continuity and diode test Automatic range selection and battery switch-off; Min/Max and Data Hold function MA - high current fuse for nominal voltage of 1000 V Protective rubber cover Lucas Nülle GmbH Page 6/35 www.lucas-nuelle.com 8 Multi13S digital multimeter LM2330 1 Universal precision lab multimeter and temperature meter with IR interface for high-quality, universal measurement and testing in educational settings, power plants, process control installations etc. 3¾-digit multimeter; resolution: ±3,100 digits Measurement classification CATII-1000V Can be connected to UniTrain-I system via IR interface Voltage and current measuring ranges: 30mV-1000V DC, 3V1000V AC; 3mA-16A DC; 30mA-10AAC Resistance ranges: 30ohm-30Mohm Special functions: °C for temperature measurements using PT100/1000 thermocouple Continuity and diode testing Automatic range selection and battery shut-off, min./max. and data hold function Safety fuse for current measurement range up to 300mA Protection against high currents in the mA range for nominal voltage of 1000V Display with bar chart and backlighting Includes protective sleeve, measuring leads, 1 x spare fuse, 9V battery, calibration certificate Lucas Nülle GmbH Page 7/35 www.lucas-nuelle.com 9 Multi 18 digital multimeter LM2331 1 Universal precision lab multimeter and temperature meter with IR interface for high-quality, universal measurement and testing in educational settings, power plants, process control installations etc. 4¾-digit multimeter; resolution: ±31,000 digits Measurement classification CATII-1000V Can be connected to UniTrain-I system via IR interface Real-time RMS measurement TRMS Voltage and current measuring ranges (AC and DC): 300mV1000V; 300µA-10A Decibel measurement Resistance ranges: 300ohm-30Mohm Capacitance measuring range 3nF to 10,000µF Frequency measuring range up to 100 kHz, counter and stopwatch Special functions: ° C for temperature measurements using PT100/1000 thermocouple Continuity and diode testing Automatic range selection and battery shut-off, min./max. and data hold function Protection against high currents in the mA range for nominal voltage of 1000V Safety fuse for all current measurement ranges (up to 10A) Display with bar chart and backlighting Includes protective sleeve, measuring leads, 2 x spare fuses, 9V battery, calibration certificate Lucas Nülle GmbH Page 8/35 www.lucas-nuelle.com 10 Max 10 digital multimeter LM2332 1 Universal and easy-to-use laboratory multimeter for measurement and testing in educational settings, power plants, process control installations etc. 3¾-digit multimeter; resolution: ±4 000 Digits Measurement classification CATII - 600V / CATIII - 300V Voltage and current measuring ranges: 400mV –1000V DC, 400mV–1000V AC; 40µA–10A DC; 40µA10A AC Measurement ranges: 100mohm-40Mohm Capacitance measuring range 1pF to 200µF Frequency measuring range 0.001Hz to 500kHz Duty cycle measurements Continuity and diode testing Automatic range selection and battery shut-off, min./max. and data hold function Includes protective sleeve, measuring leads and battery Lucas Nülle GmbH Page 9/35 www.lucas-nuelle.com 11 Insulation tester Insu 10 LM2333 1 A digital and analog meter for testing insulation resistance and continuity that can be used for all kinds of insulation measurements on electrical plant and equipment, such as domestic appliances, cables, motors, transformers etc. Insulation resistance ranges from 10kohm to 999Mohm Selection of test voltages 50V/100V/250V/500V/1000V Measurement of resistance from 0.01ohm to 99.9ohm Measurement of voltage from above 25V to 600V AC/DC "Equipment live" monitoring for voltages over 25V for any of the available functions Automatic discharging of capacitor circuits after testing Min./max. storage Memory for storing the 50 most recent measurements Adjustable threshold monitoring (Go/No Go) for the megohm range Adjustable time spans for measuring insulation resistance from 10 sec. up to 5 mins. Continuity testing with programmable threshold for continuity resistance plus acoustic signal Stopwatch function Blown fuse indication Auto power off Includes 1 set of measuring leads, 1 set of terminals, 1 set of 6 x 1.5V IEC LR6 batteries; protective rubber sleeves Lucas Nülle GmbH Page 10/35 www.lucas-nuelle.com 12 LCR-/ESR Meter 100Hz-100kHz, with USB-Interface LM2335 1 LCR-ESR-Meter, 100 Hz - 100 kHz, with USB-Port LCR meter with ESR (equivalent series resistance), for component testing in the workplace, as well as for service and maintenance. High measurement frequency of up to 100 kHz allows a highly precise work. PC software stores and evaluates the measured values. 4 ½ digit illuminated multi-function display with bargraph ESR measurement (equivalent series resistance) Basic accuracy: 0,3 % at 0,01 % resolution Auto LCR detection Pass / fail component sorting function Relative value measurement, data-hold function High Measuring frequency switchable 100/120 Hz, 1/10/100 kHz Auto-Power-Off (in battery mode) Self-calibration function USB interface and PC software Accessories: USB interface cable, software for Windows 2000/NT/XP/Vista/7, kelvin clips, case, battery and manual Measurement modes: DCR, Ls, Cs, Lp, Cp, D, Q, Rp, θ, ESR Ranges: - Capacitance: 200/2000 pF, 20 nF, 20/200 µF, 2/20 mF - Resistance: 20/200 Ω, 2/20/200 kΩ, 2/20/200 MΩ - Inductance: 20/200/2000 µH, 20/200 mH, 20/2000 H, 20 kH - DCR: 200 Ω - 200 MΩ - ESR: 0.00 Ω - 20.0 MΩ - Phase angle: -180° - 180° - D/Q: 0.001 - 1999 Operation voltages: 6 x 1,5 V AAA batteries; optional power adapter 12 V/0.5A Dimensions (WxHxD): 100x210x45mm Weight: 495g Lucas Nülle GmbH Page 11/35 www.lucas-nuelle.com 13 Power Clamp Meter with True RMS, 3 3/4-digit, 1000 A AC/DC LM2336 1 Power Clamp Meter with True RMS, 3 3/4-digit, 1000 A AC/DC Digital power clamp meter for measurements of power consumption in single-phase systems. Among other measurement functions, such as voltage, current, resistance, and Hz/Duty this clamp Meter measures the power consumption during a voltage measurement in kW. Through the illuminated LCD display with 3999 counts, the noncontact current measurement up to 1000 AAC/DC and the comprehensive multimeter functions this device is universally usable. 3 ¾ digit, 17 mm LCD; max. indication: 3999 True RMS Auto/manual range selection Data hold Backlight AC/DC power: 240 kW AC/DC current: 1000 A AC/DC voltage: 600 V Resistance- and frequency measurement Diode test and continuity test Auto power off Max. conductor size: 35 mm Safety: EN 61010-1; CAT III 600 V Accessories: carrying case, test leads, battery and manual Technical specifications: DC V: 400 mV/4/40/400/600 V; 100 µV; ± 1,5 % + 3 St. AC V: 400 mV/4/40/400/600 V; 100 µV ; ± 1,8 % + 5 St. DC A: 1000 A; 1 A; ± 1,8 % + 5 St. AC A: 1000 A; 1 A; ± 2,0 % + 5 St. DC kW: 40/240 kW; 10 W; ± 2,0 % + 5 St. AC kW: 40/240 kW; 10 W; ± 2,5 % + 5 St. Ohm: 400 Ω/4/40/400 kΩ/4/40 MΩ; 100 mΩ; ± 1,5 % + 2 St. Freq.: 5/50/500 Hz/5/50/100 kHz; 1 mHz ; ± 1,2 % + 2 St. Dimensions: 80x230x40mm (WHD) Weight: 300g Oscilloscope Oscilloscope Lucas Nülle GmbH Page 12/35 www.lucas-nuelle.com List of articles: Speicherozilloskope Pos. Product name Bestell-Nr. 14 Digital dual trace storage oscilloscope, incl. probes LM6205 Anz. 1 40-MHz analog/digital oscilloscope with unique measurement properties and evaluation capabilities. Includes an integrated 100MHz frequency and period counter and an integrated component tester. Technical data: Display: rectangular CRT 8 x 10 cm with internal grid and fastheating element Channel 1 or 2 displayed individually, alternately or in chop mode Invert, sum or difference – channel 1/2 Xt or XY modes Read-out and cursor measurement Input voltage: max. 400 V (DC + peak-to-peak AC) Vertical deviation: 14 calibrated ranges from 1 mV/cm to 20 V/cm in a 1-2-5 sequence, Horizontal deviation: 22 calibrated ranges from 0.5 s/cm to 50 ns/cm (± 3%) in a 1-2-5 sequence Triggering up to 100 MHz, automatic or level setting, rising or falling edge Trigger sources: channel 1 or 2, alternate, mains, external; LED trigger display Storage resolution: 2048 x 8 bits per channel Sampling rate (real time): 8-bit flash max. 100 MS/s, Sampling rate: max. 100 MS/s per channel in real time Component tester: 7 V rms, 7 mA rms, 50 Hz Interface RS-232 (standard) Protection: Protection class 1 (EN61010) Includes manual and software on CD-ROM, 2 probes 1:1/10:1 and mains lead Mains connection: 100 - 240 V, 50/60 Hz Dimensions: 285 x 125 x 380 mm (WxHxD) Weight: 6 kg Lucas Nülle GmbH Page 13/35 www.lucas-nuelle.com 15 Digital dual trace storage oscilloscope w. colour display, incl. probes 30MHz LM6210 1 Digital storage oscilloscope with colour LCD display, high resolution, backlighting and USB port for transmission of large quantities of data at high data rates. Technical data: Bandwidth 30MHz/125MS/s Maximum input voltage 400V 8" TFT colour display USB port, USB flash disk, LAN, VGA Cursor function Five automatic measurement functions, storage and retrieval of traces Edge and video trigger function Safety specifications: EN 61010-1 Supplied with accessories: 2 probes, mains lead, USB cable, software CD Dimensions: 350x157x120mm (WxHxD) Weight: 1.0kg Lucas Nülle GmbH Page 14/35 www.lucas-nuelle.com 16 Digital dual trace storage oscilloscope+ probes and colour-display multimeter LM6215 1 A combination of a 20MHz dual-channel digital storage oscilloscope and a true RMS multimeter to provide a mobile solution for any measuring requirements. Technical data: Bandwidth 20MHz/100MS/s 3.8" TFT colour display USB port Lithium ion rechargeable battery Video trigger function and optimised trigger sensitivity Storage capacity 6K True RMS multimeter Two isolated channels that can be used separately for multimeter use or shared with the oscilloscope USB port Safety specifications: EN 61010-1 Supplied with accessories: AC-DC adapter, 2 probes, test leads, enhancement pack for measuring small capacitances, cable for connecting USB memory, USB cable, software CD, case and instruction manual Dimensions: 115x180x40 mm (WxHxD) Weight: 0.65kg Frequency counter Frequency counter Lucas Nülle GmbH Page 15/35 www.lucas-nuelle.com Liste der Artikel: Pos. Product name Bestell-Nr. 17 Frequency counter, 100MHz LM3010 Anz. 1 Frequency counter 10 Hz to 1 GHz Universal counter with stabilised crystal oven oscillator, incorporating an 8-digit, 7-segment LED display. Modes of operation: Frequency, Period & Count Frequency range: Channel A: 10 Hz - 100 MHz Gate times, 0.01 to 10 sec. Channel B: 100 MHz to 1 GHz Period measurements: Range: 10 Hz to 2.5 MHz Gate times, 0.01 to 10 sec. Count: Frequency range. 10 Hz to 10 MHz Count range: 0 to 99 999 99 (8 digits) Input impedance: 1 Mohm/35 pF Input voltage: max. 230 V (DC + AC rms) Timebase error: < 1 ppm after 20 mins warm-up Ext. timebase: TTL-level, 10 MHz Dimensions: 205 x 76 x 267 mm (WxHxD) Weight: 2.0 kg. Function generator Function generator Lucas Nülle GmbH Page 16/35 www.lucas-nuelle.com List of articles: Pos. Product name Bestell-Nr. 18 Multi Power Supply 4x DC, 2x AC, 3-phase, function generator CO3538-8M Anz. 1 Multifunctional, compact power supply including function generator and three-phase source, suitable for any basic or advanced experiments in the fields of electrical engineering, electronics and digital electronics. It can be operated as desktop device or mounted in an experiment frame. The power supply has protective isolation and provides safety extra-low voltage in compliance with EN 61010. A standard 230-V plug is enough to connect it up. All outputs have selfresetting circuit breakers to cut off the power safely in the event of a current overload. The equipment is maintenance-free and especially suited for use by beginners. Modern power supply technology allows for low power consumption and reduced power loss. Stabilised fixed voltages, +15 V, -15 V, both 1 A Stabilised fixed voltage, +5 V, 1 A Stabilised fixed voltage for vehicles, 12 V, 1 A Stabilised adjustable voltage, 0 ... 30 V, 1 A with adjustable current limitation AC voltages, 12V, 24V, both 200 mA, 50 Hz Three-phase generator with 3 phases and N Amplitude 3 x 7/12 V Output current max. 3 x 200 mA, Frequency 1 Hz or 50 Hz Function generator 0.1 Hz ... 1 MHz in 5 ranges Output signals: sine-wave, triangle, square-wave, digital Output voltage: -10 V ... 0 ... 10 V Output with attenuator: 10:1 Output current max.: 200 mA Short-circuit-proof or with self-resetting circuit breakers on all outputs 6 Buttons for various functions 17 LEDs for use as status signal lights 2 LCD displays with blue illumination Display of DC voltage, current and current limitation Display of AC voltage and frequency USB port so that voltage sources can be controlled by computer Illuminated mains switch Experiment board with console housing Dimensions: 297 mm x 228 mm x 100 mm Weight: 3.5 kg Lucas Nülle GmbH Page 17/35 www.lucas-nuelle.com 19 Sweep Function generator 40mHz - 20MHz with frequency counter LM5710 1 These DDS function generators are of the high performance indexes with numerous function characteristics which are necessary for the fast completion of measuring. The simple and clear front panel design and the LED display interface of number and indicator light are convenient for the users to operate and observe. Moreover, the extended optional functions enhance the system characteristics. High frequency accuracy: up to 10-5 High frequency resolution: 40 mHz High waveform accuracy: 16 types of waveforms can be output Independent output for two channels Frequency- and amplitude sweeping Frequency, period, amplitude virtual - or peak-peak value selectable USB interface Crystal oscillator reference, high frequency and resolution Intregrated frequency counter up to 100 MHz and 7 W power amplifier Safety: EN 61010-1; CAT II Accessories: power cable, USB interface cable, software for Windows, BNC cable, spare fuse and operation manual Technical data: Frequency range : 40 mHz - 20 MHz Output waveforms : 16 waveforms such as sine, square, triangle, etc. Harmonic distortion : -40 dBc Total distortion :<1% Square waveform : < 35 ns rise/fall time Duty cycle : 1 - 99 % Frequency resolution : 40 mHz Amplitude range : 0 – 20 Vpp Amplitude offset : + 10 V Amplitude resolution : 2 mVpp Operation voltage : 100 – 204 V AC, 50/60 Hz, switching mode power supply Dimensions (WxHxD) : 254 x 100 x 340 mm Weight : 3 kg Lucas Nülle GmbH Page 18/35 www.lucas-nuelle.com Drehzahlmesser Pos. Product name Bestell-Nr. 20 Photo tachometer, 5-digits with laser LM3030 Anz. 1 Digital tachometer with built in laser pointer and high visible digital 5 digit, 13 mm, LCD display and blue backlight provides. Fast and accurate Non-contact RPM and surface speed measurements of rotating objects CPU-, photoelectrical technique and junction laser technique for one instrument combined (PHOTO TACH. (RPM&REV)) Plastic housing with integrated non-slip rubber-protection Measuring operation possible mobil with battery or stationary with AC-adaptor. Laser-targeting (class 2; <1 mW) Two test modes: rotate speed mode (unit: RPM) & count mode (unit: REV) Wide measure range and high resolution High visible digital LCD and backlight display Built-in memory recalls MAX / MIN and last value stored. Low battery indication / auto-range Accessories: carrying case, battery, adhesive reflecting tape mark and manual Functions and ranges: 2 ... 99999 rpm; 0,1 (2...999 rpm); 1 (1000...99999 rpm) ± 0,05 % + 1 dgt. Sample rate: 2x/sec. above 120 rpm Detecting distance: 50 mm ... 500 mm Count range RPM: 1 ... 19 999 rpm; 0,1 rpm Laser: class: 2, output: < 1 mW, wave length: 630 - 670 nm Dimensions (WxHxD): 58x160x39mm Weight: 150g Measurement Accessories: Measurement Accessories: List of articles: Pos. Product name Bestell-Nr. 21 Test probe adapter with 4mm safety plugs LM9009 Anz. 1 Adapter for test probes, with 4 mm safety plugs Lucas Nülle GmbH Page 19/35 www.lucas-nuelle.com 22 4mm Adapter for test probes LM9010 1 LM9019 1 24 Test probe, 100:1 LM9029 1 25 Test lead, BNC/4mm safety plugs, 160cm LM9031 1 LM9032 1 Flexible test probe adapter 4 mm socket for test probes 4 mm bunch plug 23 Adapter BNC/4mm safety sockets, insulated Adapter plug for connecting BNC connector to 4-mm safety sockets BNC plug, 2 insulated 4-mm safety sockets Contact rings and sockets for internal pin of BNC connector are made of gilded brass CAT II/1000 V Test lead BNC/4 mm safety plugs, 160mm long 26 Test lead, BNC/2x 4mm plug, 1.5m Coaxial test cable with BNC connector at one end and two banana plugs at the other. Terminations: BNC female (socket) and 2x 4mm plugs Dimensions: 1.5m Lucas Nülle GmbH Page 20/35 www.lucas-nuelle.com Safety connecting plugs 4mm Pos. Product name Bestell-Nr. 27 Safety connecting plug 4mm with tap (2x), black, 1000V/32A CAT II Anz. SO5126-3R 1 28 Safety connecting plug 4mm with tap (2x), brown, 1000V/32A CAT II SO5126-3S 1 Moulded insulation both sides with touch protection (saftey plug + saftey sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour black Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour brown 29 Safety connecting plug 4mm with tap (2x), grey, 1000V/32A CAT II SO5126-3T 1 SO5126-3U 1 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour grey 30 Safety connecting plug 4mm with tap (2x), red, 1000V/32A CAT II Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour red Lucas Nülle GmbH Page 21/35 www.lucas-nuelle.com 31 Safety connecting plug 4mm with tap (2x), blue, 1000V/32A CAT II SO5126-3V 1 SO5126-3W 1 SO5126-3X 1 34 Safety connecting plug 4mm with tap (2x), yellow, 1000V/32A CAT II SO5126-3Z 1 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour blue 32 Safety connecting plug 4mm with tap (2x), green/yellow, 1000V/32A CAT II Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green/yellow 33 Safety connecting plug 4mm with tap (2x), white, 1000V/32A CAT II Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour white Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour yellow Lucas Nülle GmbH Page 22/35 www.lucas-nuelle.com 35 Safety connecting plug 4mm with safety rear socket (2x), green, 1000V/32A CAT II SO5126-4A 1 Moulded insulation both sides with touch protection (safety plug + safety sockets), distance 19mm transition resistance max. 6mΩ rated data: 1000V/32A CAT II colour green Safety measurement lead, 4mm plugs Length 150 cm Pos. Product name Bestell-Nr. 36 Safety measurement cable (4mm) , 25cm, red Anz. SO5126-8A 1 SO5126-8B 1 Safety measurement lead with stackable, contact-proof 4mm plugs colour: red length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 37 Safety measurement cable (4mm), 25cm, black Safety measurement lead with stackable, contact-proof 4mm plugs colour: black length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 23/35 www.lucas-nuelle.com 38 Safety measurement cable (4mm) , 25cm, yellow SO5126-8C 1 SO5126-8D 1 SO5126-8E 1 Safety measurement lead with stackable, ccontact-proof 4mm plugs length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 39 Safety measurement cable (4mm) , 25cm, brown Safety measurement lead with stackable, contact-proof 4mm plugs colour: brown length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 40 Safety measurement cable (4mm) , 25cm, blue Safety measurement lead with stackable, ccontact-proof 4mm plugs colour: blue length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 24/35 www.lucas-nuelle.com 41 Safety measurement cable (4mm) , 25cm, white SO5126-8F 1 SO5126-8G 1 SO5126-8H 1 Safety measurement lead with stackable, contact-proof 4mm plugs colour: white length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 42 Safety measurement cable (4mm) , 25cm, green/yellow Safety measurement lead with stackable, contact-proof 4mm plugs colour: green/yellow length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 43 Safety measurement cable (4mm) , 25cm, grey Safety measurement lead with stackable, contact-proof 4mm plugs colour: grey length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A Lucas Nülle GmbH Page 25/35 www.lucas-nuelle.com 44 Safety measurement cable (4mm) , 25cm, green SO5126-8J 1 SO5126-8K 1 SO5126-8L 1 Safety measurement lead with stackable, contact-proof 4mm plugs colour: green length: 25 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 45 Safety measurement cable (4mm), 50cm, red Safety measurement lead with stackable, contact-proof 4mm plugs colour: red length: 50 cm cable cross-section 2,5 mm2 ratings deliver: 600V CAT II, 32A 46 Safety measurement cable (4mm), 50cm, black Safety measurement lead with stackable, contact-proof 4mm plugs Colour: black Length: 50 cm Wire cross section 2.5 mm2 Lucas Nülle GmbH Page 26/35 www.lucas-nuelle.com 47 Safety measurement cable (4mm), 50cm, yellow SO5126-8M 1 SO5126-8N 1 SO5126-8P 1 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: yellow Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A 48 Safety measurement cable (4mm), 50cm, brown Safety measurement lead with stackable, contact-proof 4mm plugs Colour: brown Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A 49 Safety measurement cable (4mm), 50cm, blue Safety measurement lead with stackable, contact-proof 4mm plugs Colour: blue Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A Lucas Nülle GmbH Page 27/35 www.lucas-nuelle.com 50 Safety measurement cable (4mm), 50cm, white SO5126-8Q 1 SO5126-8R 1 SO5126-8S 1 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: white Length: 50cm Cross-section: 2.5 mm2 Rating: 600V, CAT II, 32A 51 Safety measurement cable (4mm), 50cm, green/yellow Safety measurement lead with stackable, contact-proof 4mm plugs Colour: green/yellow Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A 52 Safety measurement cable (4mm), 50cm, grey Safety measurement lead with stackable, contact-proof 4mm plugs Colour: grey Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A Lucas Nülle GmbH Page 28/35 www.lucas-nuelle.com 53 Safety measurement cable (4mm), 50cm, green SO5126-8T 1 SO5126-8U 1 SO5126-8V 1 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: green Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A 54 Safety measurement cable (4mm), 100cm, red Safety measurement leads with stackable, contact-proof 4mm plugs Colour: red Length: 100 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A 55 Safety measurement cable (4mm), 100cm, black Safety measurement leads with stackable, contact-proof 4-mm plugs Colour :black Length: 100 cm Wire cross-section 2.5 mm 2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 29/35 www.lucas-nuelle.com 56 Safety measurement cable (4mm), 100cm, yellow SO5126-8W 1 SO5126-8X 1 SO5126-9A 1 Safety measurement lead with stackable, contact-proof 4mm plugs Colour: yellow Length: 50 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A 57 Safety measurement cable (4mm), 100cm, brown Safety measurement lead with stackable, contact-proof 4mm plugs Colour: brown Length: 100 cm Wire cross section 2.5 mm2 Rating data: 600V, CAT II, 32A 58 Safety measurement cable (4mm), 100cm, blue Safety measurement lead with stackable, contact-proof 4mm plugs Colour: blue Length: 100 cm Wire cross-section 2.5 mm2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 30/35 www.lucas-nuelle.com 59 Safety measurement cable (4mm), 100cm, white SO5126-9B 1 SO5126-9C 1 SO5126-9D 1 Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: white Length: 100 cm Wire cross-section, 2.5 mm 2 Rating: 600V, CAT II, 32A 60 Safety measurement cable (4mm), 100cm, green/yellow Safety measurement lead with stackable, contact-proof 4mm plugs Colour: green/yellow Length: 100 cm Wire cross-section 2.5 mm2 Rating: 600V, CAT II, 32A 61 Safety measurement cable (4mm), 100cm, grey Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: grey Length: 100 cm Wire cross-section, 2.5 mm 2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 31/35 www.lucas-nuelle.com 62 Safety measurement cable (4mm), 100cm, green SO5126-9E 1 SO5126-9F 1 SO5126-9G 1 Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: green Length: 100 cm Wire cross-section, 2.5 mm 2 Rating: 600V, CAT II, 32A 63 Safety measurement cable (4mm), 150cm, red Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: red Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A 64 Safety measurement cable (4mm), 150cm, black Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: black Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 32/35 www.lucas-nuelle.com 65 Safety measurement cable (4mm), 150cm, yellow SO5126-9H 1 SO5126-9J 1 SO5126-9K 1 Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: yellow Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A 66 Safety measurement cable (4mm), 150cm, brown Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: brown Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A 67 Safety measurement cable (4mm), 150cm, blue Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: blue Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 33/35 www.lucas-nuelle.com 68 Safety measurement cable (4mm), 150cm, white SO5126-9L 1 SO5126-9M 1 SO5126-9N 1 Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: white Length: 150 cm Wire cross-section, 2.5 mm 2 Rating: 600V, CAT II, 32A 69 Safety measurement cable (4mm), 150cm, green/yellow Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: yellow/green Length: 150 cm Wire cross-section, 2.5 mm 2 Rating: 600V, CAT II, 32A 70 Safety measurement cable (4mm), 150cm, grey Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: grey Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 34/35 www.lucas-nuelle.com 71 Safety measurement cable (4mm), 150cm, green SO5126-9P 1 Safety measurement cables with stackable, contact-proof 4-mm plugs Colour: green Length: 150 cm Wire cross-section, 2.5 mm2 Rating: 600V, CAT II, 32A Lucas Nülle GmbH Page 35/35 www.lucas-nuelle.com