Dimension Sheet for
Half-wave Rectifiers and Bridge Rectifiers Type 02_.000.6
(M.02+0006.EN)
Application
Rectifiers are used to connect DC consumers to alternating voltage
supplies, for example electromagnetic brakes and clutches (ROBAstop®, ROBA-quick®, ROBATIC®), electromagnets, electrovalves,
contactors, switch-on safe DC motors, etc.
Function
The AC input voltage (VAC) is rectified (VDC) in order to operate
DC voltage units. Also, voltage peaks, which occur when switching
off inductive loads and which may cause damage to insulation and
contacts, are limited and the contact load reduced.
Dimensions (mm)
Electrical Connection (Terminals)
A
C
E
19
5
B
ØD
1 + 2 Input voltage
3 + 4Connection for an external switch for DC-side switching
5 + 6 Coil
7 – 10 Free nc terminals (only for Size 2)
Order Number
__
/ 0
2
Size
1
up to
4
__ . 0
4
5
0
0 . 6
Half-wave rectifier
Bridge rectifier
B
30
30
30
Bridge rectifier
Calculation output voltage
Type
Max. input voltage
Max. output voltage
Output current at
UAC = 115 VAC
UAC = 230 VAC
UAC = 400 VAC
UAC = 500 VAC
UAC = 600 VAC
± 10 %
≤ 50°C
max. 85 °C
≤ 50 °C
up to 85 °C
≤ 50 °C
up to 85 °C
≤ 50 °C
up to 85 °C
≤ 50 °C
up to 85 °C
≤ 50 °C
up to 85 °C
Peak reverse voltage
Rated insulation voltage
Pollution degree (insulation coordination)
Device fuses
Recommended microfuse, switching capacity H
UAC
UDC
IRMS
IRMS
PN
PN
PN
PN
PN
PN
PN
PN
PN
PN
URMS
[VAC]
[VDC]
[A]
[A]
[W]
[W]
[W]
[W]
[W]
[W]
[W]
[W]
[W]
[W]
[V]
[VRMS]
The microfuse corresponds to the max. possible connection
capacity. If fuses are used corresponding to the actual capacities,
the permitted limit integral I²t must be observed on selection.
Permitted limit integral
Protection
Terminals
Ambient temperature
Storage temperature
Conformity markings
Installation conditions
26/06/2015 GC/TH
Page 1 of 1
A
34
54
64
C
25
44
54
ØD
3.5
4.5
4.5
E
4.5
5.0
5.0
Accessories: Mounting bracket set for 35 mm rail acc. EN 60715: Article-No. 1803201
Technical Data
Max.
coil nominal
capacity
at
Size
1
2
3/4
VDC = VAC x 0.9
VDC = VAC x 0.45
1/025
2/025
1/024
2/024
3/024
230
230
400
400
500
207
207
180
180
225
2.5
2.5
3.0
4.0
4.0
1.7
1.7
1.8
2.4
2.4
260
260
177
177
517
517
312
416
416
352
352
187
250
250
540
720
720
324
432
432
900
540
1600
1600
2000
1600
2000
320
320
500
500
630
1
1
1
1
1
To be included in the input voltage line.
FF 3.15 A
l2t
[A2s]
[°C]
[°C]
Half-wave rectifier
FF 3.15 A
FF 4 A
40
FF 5 A
FF 5 A
4/024
600
270
4.0
2.4
416
250
720
432
900
540
1080
648
2000
630
1
FF 5 A
40
50
100
50
50
IP65 components, encapsulated / IP20 terminals
Cross-section 0.14 – 1.5 mm2 (AWG 26 – 14)
-25 up to +85
-40 up to +85
UL, CE
UL, CE
UL, CE
UL, CE
UL, CE
CE
The installation position can be user-defined. Please ensure sufficient
heat dissipation and air convection! Do not install near to sources of
intense heat!