Dimension Sheet for Half-wave Rectifiers and Bridge Rectifiers Type 02_.000.6 (M.02+0006.EN) Application Rectifiers are used to connect DC consumers to alternating voltage supplies, for example electromagnetic brakes and clutches (ROBAstop®, ROBA-quick®, ROBATIC®), electromagnets, electrovalves, contactors, switch-on safe DC motors, etc. Function The AC input voltage (VAC) is rectified (VDC) in order to operate DC voltage units. Also, voltage peaks, which occur when switching off inductive loads and which may cause damage to insulation and contacts, are limited and the contact load reduced. Dimensions (mm) Electrical Connection (Terminals) A C E 19 5 B ØD 1 + 2 Input voltage 3 + 4Connection for an external switch for DC-side switching 5 + 6 Coil 7 – 10 Free nc terminals (only for Size 2) Order Number __ / 0 2 Size 1 up to 4 __ . 0 4 5 0 0 . 6 Half-wave rectifier Bridge rectifier B 30 30 30 Bridge rectifier Calculation output voltage Type Max. input voltage Max. output voltage Output current at UAC = 115 VAC UAC = 230 VAC UAC = 400 VAC UAC = 500 VAC UAC = 600 VAC ± 10 % ≤ 50°C max. 85 °C ≤ 50 °C up to 85 °C ≤ 50 °C up to 85 °C ≤ 50 °C up to 85 °C ≤ 50 °C up to 85 °C ≤ 50 °C up to 85 °C Peak reverse voltage Rated insulation voltage Pollution degree (insulation coordination) Device fuses Recommended microfuse, switching capacity H UAC UDC IRMS IRMS PN PN PN PN PN PN PN PN PN PN URMS [VAC] [VDC] [A] [A] [W] [W] [W] [W] [W] [W] [W] [W] [W] [W] [V] [VRMS] The microfuse corresponds to the max. possible connection capacity. If fuses are used corresponding to the actual capacities, the permitted limit integral I²t must be observed on selection. Permitted limit integral Protection Terminals Ambient temperature Storage temperature Conformity markings Installation conditions 26/06/2015 GC/TH Page 1 of 1 A 34 54 64 C 25 44 54 ØD 3.5 4.5 4.5 E 4.5 5.0 5.0 Accessories: Mounting bracket set for 35 mm rail acc. EN 60715: Article-No. 1803201 Technical Data Max. coil nominal capacity at Size 1 2 3/4 VDC = VAC x 0.9 VDC = VAC x 0.45 1/025 2/025 1/024 2/024 3/024 230 230 400 400 500 207 207 180 180 225 2.5 2.5 3.0 4.0 4.0 1.7 1.7 1.8 2.4 2.4 260 260 177 177 517 517 312 416 416 352 352 187 250 250 540 720 720 324 432 432 900 540 1600 1600 2000 1600 2000 320 320 500 500 630 1 1 1 1 1 To be included in the input voltage line. FF 3.15 A l2t [A2s] [°C] [°C] Half-wave rectifier FF 3.15 A FF 4 A 40 FF 5 A FF 5 A 4/024 600 270 4.0 2.4 416 250 720 432 900 540 1080 648 2000 630 1 FF 5 A 40 50 100 50 50 IP65 components, encapsulated / IP20 terminals Cross-section 0.14 – 1.5 mm2 (AWG 26 – 14) -25 up to +85 -40 up to +85 UL, CE UL, CE UL, CE UL, CE UL, CE CE The installation position can be user-defined. Please ensure sufficient heat dissipation and air convection! Do not install near to sources of intense heat! Chr. Mayr GmbH + Co. KG Eichenstraße 1, D-87665 Mauerstetten, Germany Tel.: +49 8341 804-0, Fax: +49 8341 804-421 www.mayr.com, E-Mail: info@mayr.com