Passive Infrared

advertisement
NEXION Commercial
Lighting Controls
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Ceiling Mount Passive Infrared
Occupancy Sensor with
InstinctTM Technology
Passive Infrared
10-30 V/DC
INS
Commercial Specification Grade Infrared Occupancy Sensor
FEATURES
• California Title 24 compliant.
• Self-adjusting Auto OFF delay of 10 to 30
minutes.
• Self-adapting sensors with Instinct
Technology require no adjustment at
installation and provide continuous, realtime, self-adjusting sensitivity and time delay.
• DIP Switch override allows time delay to be
locked at 30 minutes.
• DIP Switch selectable feature prevents
unnecessary “lights ON” following power
sweeps in facilities with computer control
systems.
• BAS compatible.
• Manual ON/OFF feature when wired to a
normally open momentary push button switch.
• Complete no-gap coverage; NEMA WD7
Guide robotic method utilized to verify
coverage patterns.
• Paintable off-white ABS molded housing.
• Adjustable ambient light level feature.
• Segmented Fresnel lens provides optimum
sensitivity and performance.
• Open collector output to switch up to 10
switchpacks.
INSTINCT
4.70"
(119.4mm)
Wire Leads – Ceiling Mount
Description
Catalog No.
450 sq. ft.
(41.7 sq. m)
Surface Mount Passive Infrared
Occupancy Sensor Isolated Relay
1200 sq. ft.
(111.3 sq. m)
Surface Mount Passive Infrared
Occupancy Sensor Isolated Relay
I AHOMC-P-0450-R
•
I AHOMC-P-1200-R
•
Coverage Areas
TOP VIEW
AHOMC-P-0450
15ft
(4.6m)
TOP VIEW
Up to 450 sq. ft.
Max. mounting
height: 12 ft.
10ft
(3m)
Up to 1200 sq. ft.
Max. mounting
height: 12 ft.
20ft
(6.1m)
5ft
(1.5m)
10ft
(3.0m)
0 ft.
0 ft.
5ft
(1.5m)
10ft
(3.0m)
10ft
(3m)
20ft
(6.1m)
15ft
(4.6m)
30ft
(9.1m)
SIDE VIEW 0 ft.
AHOMC-P-1200
30ft
(9.1m)
SIDE VIEW 0 ft.
8ft
(2.4m)
24ft
14ft
(7.3m)
(4.3m)
8ft
(2.4m)
12ft
(3.7m)
9ft
7ft 5ft 3ft
(2.7m) (2.1m) (1.5m) (0.9m)
0
3ft 5ft 7ft 9ft 12ft
(0.9m) (1.5m) (2.1m) (2.7m) (3.7m)
TESTING & CODE COMPLIANCE
MATERIAL CHARACTERISTICS
• Listed to UL 508
• California Title 24 Energy Code compliant
• Environmental: Flammability meets UL94
requirements; V0 rated
• Temperature Rating: 15ºC to 26ºC (60ºF to 80ºF)
NAFTA Compliant
www.cooperwiringdevices.com
8ft
3ft 0 3ft
(2.4m) (0.9m)
8ft
(0.9m) (2.4m)
14ft
24ft
(4.3m)
(7.3m)
IN
INS
4.70"
(119.4mm)
AHOMC-P-1200-R
Coverage Area
TM
1.50"
(38.1mm)
Occupancy Sensor
Specification & Performance Data
Project Name:
Prepared By:
Project Number:
Date:
Catalog Number:
Type:
Ceiling Mount Passive Infrared
Occupancy Sensor with
InstinctTM Technology
Passive Infrared
10-30 V/DC
Application
The Passive Infrared ceiling sensors with Instinct Technology can be used individually or in combination to provide lighting control
and integration with HVAC control throughout a building. Instinct Technology enabled sensors continuously self-adjusts sensitivity
and time delay automatically and immediately in response to occupant behavior. There is no need for time consuming manual
adjustments or for the sensor to “learn” behavior patterns over extensive periods of time. These ceiling mount PIR sensors are
surface mounted low voltage models and are ideal for offices, conference rooms, storage areas, common areas, other indoor office
spaces and hallways (refer to coverage patterns).
Device Type
Wiring Type
One Switchpack, One Sensor Wiring Diagram
Ceiling Mount Occupancy
Sensor, AHOMC-P Series
Use only one Manual-Off option
Pre-stripped wire leads
• Listed to UL 508
Specifications:
Environmental
Testing & Code
Compliance
• California Title 24 Energy Code
compliant
Warranty
5-year limited warranty
Flammability
Meets UL 94 requirements; V0
rated
Optional Switch for Manual ON/OFF
Capability. Use 3A 24VDC Momentary
Wall Switch.
Temperature Rating 15ºC to 26ºC (60°F to 80°F)
Humidity Rating
Relative humidity less than 95%,
non-condensing
Operating Areas
For indoor ceiling use only
Specifications:
Materials
Specifications:
Operation
Specifications:
Mechanical
Specifications:
Electrical
Power Requirements 10-30 VDC from switchpack
Maximum Current
Per Sensor
25mA
Output
Open collector output to switch up
to 10 switchpacks
Isolated Form C
Relay
Available in -R models; ratings: 1A,
30 VDC/VAC
Detection
Technology
Passive Infrared
Mounting
NEMA double-gang box (use
#AHACMP) or mounting post &
washer
Two Switchpacks, One Sensor Wiring Diagram
LED Indicating Lamp Red
from 10 min. to 30
Optional Switch for Manual Self-adjusting
ON/OFF
Time Delay
Capability. Use 3A 24VDC Momentary
min.
Wall Switch.
Adjustable, from 10 to 300 footAmbient Light
candles
Feature
1st sensor occupancy controlled
2nd sensor occupancy & daylight
controlled
Optional Switch for Manual ON/OFF
Capability. Use 3A 24VDC Momentary
Wall Switch.
Coverage
450 sq ft. or 1200 sq. ft
DIP Switch
Accessed through removable plate
Lens
Fresnel lens
Housing
Medium-impact injection molded
ABS resin housing, paintable
Specifications subject to
change without notice.
www.cooperwiringdevices.com
2-CLCCPIRSPSH-0211