NEXION Commercial Lighting Controls Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Ceiling Mount Passive Infrared Occupancy Sensor with InstinctTM Technology Passive Infrared 10-30 V/DC INS Commercial Specification Grade Infrared Occupancy Sensor FEATURES • California Title 24 compliant. • Self-adjusting Auto OFF delay of 10 to 30 minutes. • Self-adapting sensors with Instinct Technology require no adjustment at installation and provide continuous, realtime, self-adjusting sensitivity and time delay. • DIP Switch override allows time delay to be locked at 30 minutes. • DIP Switch selectable feature prevents unnecessary “lights ON” following power sweeps in facilities with computer control systems. • BAS compatible. • Manual ON/OFF feature when wired to a normally open momentary push button switch. • Complete no-gap coverage; NEMA WD7 Guide robotic method utilized to verify coverage patterns. • Paintable off-white ABS molded housing. • Adjustable ambient light level feature. • Segmented Fresnel lens provides optimum sensitivity and performance. • Open collector output to switch up to 10 switchpacks. INSTINCT 4.70" (119.4mm) Wire Leads – Ceiling Mount Description Catalog No. 450 sq. ft. (41.7 sq. m) Surface Mount Passive Infrared Occupancy Sensor Isolated Relay 1200 sq. ft. (111.3 sq. m) Surface Mount Passive Infrared Occupancy Sensor Isolated Relay I AHOMC-P-0450-R • I AHOMC-P-1200-R • Coverage Areas TOP VIEW AHOMC-P-0450 15ft (4.6m) TOP VIEW Up to 450 sq. ft. Max. mounting height: 12 ft. 10ft (3m) Up to 1200 sq. ft. Max. mounting height: 12 ft. 20ft (6.1m) 5ft (1.5m) 10ft (3.0m) 0 ft. 0 ft. 5ft (1.5m) 10ft (3.0m) 10ft (3m) 20ft (6.1m) 15ft (4.6m) 30ft (9.1m) SIDE VIEW 0 ft. AHOMC-P-1200 30ft (9.1m) SIDE VIEW 0 ft. 8ft (2.4m) 24ft 14ft (7.3m) (4.3m) 8ft (2.4m) 12ft (3.7m) 9ft 7ft 5ft 3ft (2.7m) (2.1m) (1.5m) (0.9m) 0 3ft 5ft 7ft 9ft 12ft (0.9m) (1.5m) (2.1m) (2.7m) (3.7m) TESTING & CODE COMPLIANCE MATERIAL CHARACTERISTICS • Listed to UL 508 • California Title 24 Energy Code compliant • Environmental: Flammability meets UL94 requirements; V0 rated • Temperature Rating: 15ºC to 26ºC (60ºF to 80ºF) NAFTA Compliant www.cooperwiringdevices.com 8ft 3ft 0 3ft (2.4m) (0.9m) 8ft (0.9m) (2.4m) 14ft 24ft (4.3m) (7.3m) IN INS 4.70" (119.4mm) AHOMC-P-1200-R Coverage Area TM 1.50" (38.1mm) Occupancy Sensor Specification & Performance Data Project Name: Prepared By: Project Number: Date: Catalog Number: Type: Ceiling Mount Passive Infrared Occupancy Sensor with InstinctTM Technology Passive Infrared 10-30 V/DC Application The Passive Infrared ceiling sensors with Instinct Technology can be used individually or in combination to provide lighting control and integration with HVAC control throughout a building. Instinct Technology enabled sensors continuously self-adjusts sensitivity and time delay automatically and immediately in response to occupant behavior. There is no need for time consuming manual adjustments or for the sensor to “learn” behavior patterns over extensive periods of time. These ceiling mount PIR sensors are surface mounted low voltage models and are ideal for offices, conference rooms, storage areas, common areas, other indoor office spaces and hallways (refer to coverage patterns). Device Type Wiring Type One Switchpack, One Sensor Wiring Diagram Ceiling Mount Occupancy Sensor, AHOMC-P Series Use only one Manual-Off option Pre-stripped wire leads • Listed to UL 508 Specifications: Environmental Testing & Code Compliance • California Title 24 Energy Code compliant Warranty 5-year limited warranty Flammability Meets UL 94 requirements; V0 rated Optional Switch for Manual ON/OFF Capability. Use 3A 24VDC Momentary Wall Switch. Temperature Rating 15ºC to 26ºC (60°F to 80°F) Humidity Rating Relative humidity less than 95%, non-condensing Operating Areas For indoor ceiling use only Specifications: Materials Specifications: Operation Specifications: Mechanical Specifications: Electrical Power Requirements 10-30 VDC from switchpack Maximum Current Per Sensor 25mA Output Open collector output to switch up to 10 switchpacks Isolated Form C Relay Available in -R models; ratings: 1A, 30 VDC/VAC Detection Technology Passive Infrared Mounting NEMA double-gang box (use #AHACMP) or mounting post & washer Two Switchpacks, One Sensor Wiring Diagram LED Indicating Lamp Red from 10 min. to 30 Optional Switch for Manual Self-adjusting ON/OFF Time Delay Capability. Use 3A 24VDC Momentary min. Wall Switch. Adjustable, from 10 to 300 footAmbient Light candles Feature 1st sensor occupancy controlled 2nd sensor occupancy & daylight controlled Optional Switch for Manual ON/OFF Capability. Use 3A 24VDC Momentary Wall Switch. Coverage 450 sq ft. or 1200 sq. ft DIP Switch Accessed through removable plate Lens Fresnel lens Housing Medium-impact injection molded ABS resin housing, paintable Specifications subject to change without notice. www.cooperwiringdevices.com 2-CLCCPIRSPSH-0211