Series L10 Fusible & Non-fusible Disconnect Switches Sprecher + Schuh’s L10 series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications that require small panel space and superior short circuit protection. Big performance in a small package Maximum protection for downstream equipment L10 switches are engineered to provide excellent short-circuit protection for downstream equipment. These switches accept the latest small-dimension HRCI-J and HRCII-C fuses. This Type 2 protection limits let-through currents to levels specified for IEC equipment, and ensures that when the short circuit is cleared, the device will be operable. TIP! : Devices Meets the toughest safety standards ng he ct Switc Disconne Fusible n? plicatio Load or Control, r Your Ap Fo st Be Which is Manual Switchi s… on Data Applicati ct Switch le Disconne Typical Load ch Typical Fusib Break Swit ch SSNA9000 rol Swit Typical Cont To learn the basic differences between control, load and fusible disconnect switches and how to apply them, ask your Sprecher + Schuh representative for publication no: Tech-LMSD Common parts reduce inventory Universal auxiliary contact blocks fit on all frame sizes, reducing inventory. In addition, all 30 and 60A switches use the same operating handles and shafts, ditto for the 100, 200 and 400A frame sizes. On-board fuse carriers also eliminate the need for extra components while reducing panel space requirements. Comprehensive standards and approvals L10 disconnect switches conform to UL 98 standards (100-400A switches) and UL1087 standards (30 & 60A switches); are UL Listed, CSA and are designed to meet IEC 947-3, and applicable NEMA requirements. L Disconnect Switches L10 disconnects are rated to 400A and can be operated at up to 600V. They protect motors up to 250HP (@460V). The L10 may be installed on circuits capable of delivering up to 100,000A of short circuit fault current; levels typically found in modern industrial facilities. This performance comes in a small package, leaving room for additional branch circuit components within the panel. The L10 series is suitable for use in service entrance applications. Further insuring safety, line-side terminal shields are standard on all L10 disconnects. Non-fused switches (30 & 60A) feature “dead-front” construction while fuse covers are available for all devices, preventing contact with live parts. L10 Suitable as a Service Entrance Disconnecting Means ® Up to four auxiliary contact blocks can be fitted on each L10 disconnect switch L45 Disconnect Switches Series L10 UL/CSA Fused Disconnect Switches Maximum Horsepower ➊ 1 Ø (60Hz) 120V 240V Three Phase (60Hz) 200V 240V 460V DC 600V 125V 250V Catalog Number Price Dimension Code Switch (typical) Amp Rating (A) UL Class J and CSA HRCI-J Fuses ➋ 30 2 3 7.5 7.5 15 20 3 5 L10-NJ030P3 362 A1 60 3 10 15 15 30 50 5 10 L10-NJ060P3 471 B1 100 ~ 7.5 ~ 30 60 75 ~ 20 L10-NJ100P3 744 C1 200 ~ 10 ~ 60 125 150 ~ 40 L10-NJ200P3 1641 D1 400 ~ ~ 100 125 250 300 ~ 50 L10-NJ400P3 3136 F1 CSA HRCII-C Fuses 30 2 3 7.5 7.5 15 20 ~ ~ L10-NA200P3 362 A1 60 3 10 15 15 30 50 ~ ~ L10-NA300P3 471 B1 100 ~ 15 25 30 60 75 ~ ~ L10-NH100P3 744 D1 200 ~ 30 50 60 125 150 ~ ~ L10-NH200P3 1641 E1 400 ~ 50 100 125 250 300 ~ ~ L10-NH400P3 3136 F1 UL/CSA Non-Fused Disconnect Switches ➌ 240V 200V 240V 460V 600V 125V 30 2 3 7.5 7.5 15 20 3 5 L10-NN030P3 305 A2 60 3 10 15 15 30 50 5 10 L10-NN060P3 414 B2 100 ~ 7.5 ~ 30 60 75 ~ 20 L10-NN100P3 744 C1 200 ~ 10 ~ 60 125 150 ~ 40 L10-NN200P3 1641 D1 400 ~ ~ 100 125 250 300 ~ 50 L10-NN400P3 3136 F1 Three Phase (60Hz) DC 250V Catalog Number Price Note: L10 Fusible and Non-fusible Disconnect Switches with dimension codes D, E & F require lugs. Sprecher + Schuh lugs available on page L49. Ordering Instructions •Specify Disconnect Switch catalog number (page L46) •Specify desired switch handle catalog number (page L47) •Specify desired operating shaft catalog number (page L48) •Specify desired accessories (page L49) L46 ➊Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. ➋Only UL listed Class J and CSA Certified HRCI-J fuses are suitable for use with these disconnect switches. ➌Non-fused disconnect switches must use separately installed UL Listed Class J, CC or T fuses or CSA Certified HRCI-J fuses. Discount Schedule B-7 SSNA9000 L10 Disconnect Switches L 120V 1 Ø (60Hz) Dimension Code Switch (typical) Maximum Horsepower ➊ Amp Rating (A) Disconnect Switches Series L10 Switch Handle Assemblies Switch Handle Assembly ➊ Type R Handle with defeater Description Color Type R Handle For 30A and 60A switches -With Defeater -Lockable: 3 locks ➋ Black Type R Handle without defeater Pistol Grip Handle with defeater Pistol Grip Handle without defeater 103 X 103mm Type 1 – IP42 L10-HS1 36 Type 3R, 3, 12, 4, 4X – IP66 L10-HS4 56 Type 1 – IP42 L10-HS1E 36 Type 3R, 3, 12, 4, 4X – IP66 L10-HS4E 56 Type 1 – IP42 L10-HS1-N2 68 Type 3R, 3, 12, 4, 4X – IP66 L10-HS4-N2 56 Type 1 – IP42 L10-HS1E-N2 68 Type 3R, 3, 12, 4, 4X – IP66 L10-HS4E-N2 56 Type 1 – IP42 L10-HM1 68 Type 3R, 3, 12, 4, 4X – IP66 L10-HM4 104 Type 1 – IP42 L10-HM1E 68 Type 3R, 3, 12, 4, 4X – IP66 L10-HM4E 104 Type 1 – IP42 L10-HM1-N2 68 Type 3R, 3, 12, 4, 4X – IP66 L10-HM4-N2 104 Type 1 – IP42 L10-HM1E-N2 68 Type 3R, 3, 12, 4, 4X – IP66 L10-HM4E-N2 104 Red/Yellow Black Red/Yellow 103 X 103mm Pistol Grip Handle For 100A, 200A and 400A switches ➌ -Without Defeater -Lockable: 3 locks ➋ Price Black 76 x 76mm Pistol Grip Handle For 100A, 200A and 400A switches ➌ -With Defeater -Lockable: 3 locks ➋ Catalog Number Red/Yellow 76 x 76mm Type R Handle For 30A and 60A switches -Without Defeater -Lockable: 3 locks ➋ Degree of Protection Black Red/Yellow SSNA9000 L10 Disconnect Switches L ➊Mounting screws included with Switch Handle Assembly. ➋Lockable in OFF position (and ON position with special modification). ➌Can be used on 30 and 60A switches. Select L10-R1M or L10-R2M shaft. Discount Schedule B-7 L47 Disconnect Switches Series L10 Metal Operating Shafts Shaft (typical) Switch Dimension Code For use with handle type… A1, A2 B1, B2 Type R (L10-30/60A) A1, A2 B1, B2 Pistol Grip (L10-30/60A) C1, D1 Pistol Grip (L10-100/200A) E1, F1 Operating Shaft Length (mm) Pistol Grip (L10-NH200/400A) Catalog Number Price 263 L10-R1 22.75 457 L10-R2 32.50 263 L10-R1M 34.00 457 L10-R2M 45.50 200 L10-R3 27.50 403 L10-R4 52.00 278 L10-R5 52.00 532 L10-R6 97.50 Catalog Number Price L10-HSG1 6.50 Catalog Number Price L10-GA10 L10-GA01 L10-GA11 L10-GA20 L10-GA02 17.00 17.00 27.25 27.25 27.25 Operating Shaft Accessories Accessory Description Shaft Guide - Increases the alignment tolerance of the shaft to the switch handle. For L10-R1(2) shafts Accessories Accessory Description Auxiliary Contact Blocks One pole (NO) One pole (NC) Two pole (1 NO/1 NC) Two pole (NO) Two pole (NC) ➊➋ ➊➋ ➊➋ ➊➋ ➊➋ Auxiliary Contact Adaptor - Required for fitting auxiliary contacts to all 30 & 60A fused and non-fused disconnect switches. One required. L10-AA 8.00 Auxiliary Contact Support Kit - Required when mounting more than two Auxiliary Contact Blocks per switch. L10-A1 24.50 ➊30 & 60A disconnect switches require Auxiliary Contact Adaptor (L10-AA) for installation of auxiliary contacts. ➋A maximum of four contact blocks can be installed on each disconnect switch. When more than two contact blocks are used, the Auxiliary Contact Support Kit (L10-A1) must be installed. L48 Discount Schedule B-7 SSNA9000 L10 Disconnect Switches L Disconnect Switches Series L10 Accessories (Continued) Accessory Description Catalog Number Price Padlocking Kit For 30 & 60A switches L10-P1 19.50 Switch Handle Instruction Label - For use with all Switch Handle Assemblies (10 per package - priced per package) L10-L1 4.75 L10-FCA2 ➋ L10-FCJ60 ➋ L10-FCC1 ➌ L10-FCD1 L10-FCE1 L10-FCF1 34.00 40.50 37.50 52.00 71.50 97.50 L10-LNC1 ➋ L10-LNC2 ➋ L10-LNC3 ➌ L10-LNC4 L10-LNC5 L10-LNC6 13.00 22.75 32.50 45.50 65.00 84.50 L10-LE1 41.00 Fuse Covers ➊ Dim. Code Quantity Req’d A1, A2 1 B1, B2 1 C1 3 D1 3 E1 3 F1 3 Replacement Terminal Shield ➋➌ All Disconnect Switches come standard with one Terminal Shield. For use on either line or load side of the disconnect switch. Dim. Code A1, A2 B1, B2 C1 D1 E1 F1 Terminal Lugs - 3 per package Dimension Code Wire Size D1 10mm2–50mm2 (L10-NH100P3 only) #8–1/0 AWG 16mm2–120mm2 #6–250MCM AWG L10-LF1 92.75 E1 25mm2–240mm2 #4–500MCM AWG L10-LG1 136.50 F1 Two 50mm2–150mm2 Two 1/0–350MCM AWG L10-LH1 197.00 L SSNA9000 L10 Disconnect Switches D1 ➊Also used for covering the shorting bars on 100, 200 and 400A Non-fused Disconnect switches. ➋30…60A switches are supplied with line and load terminal shields, dead-front for non-fused disconnects, and fuse cover for fused disconnects. Terminal shields listed on this page are for renewal parts only. ➌100…400A switches are supplied with line side lug (terminal) shields only. 100…400A switches do not include dead-front or fuse covers. Load side terminal and fuse covers must be ordered separately as required. Discount Schedule B-7 L49 Disconnect Switches Series L10 L10 Enclosed Motor Disconnects (UL and CSA Approved Enclosures) Type 3/4/12 Watertight, Dusttight Sheetmetal Enclosure - IP66 Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure - IP66 Type 4/4X Watertight, Corrosion-Resistant Non-metallic Enclosure - IP66 Amp/Horsepower Rating 3Ø (60 Hz) 240V 200V 240V 460V 600V 2 3 7.5 7.5 15 20 Catalog Number Price Catalog Number Price L10-CN030P3 1056 A2 Catalog Number Price Dimension Code 1Ø (60 Hz) 120V Dimension Code Horsepower Dimension Code UL/ CSA Amps L10-KN030P3 561 A2 Non-Fused 30 L10-FN030P3 561 A2 60 3 10 15 15 30 50 L10-FN060P3 993 B2 L10-CN060P3 1337 B2 L10-KN060P3 993 B2 100 ~ 7.5 ~ 30 60 75 L10-FN100P3 1433 C1 L10-CN100P3 2629 C1 L10-KN100P3 1433 C1 200 ~ 10 ~ 60 125 150 L10-FN200P3 2390 D1 L10-CN200P3 3695 D1 L10-KN200P3 2389 D1 400 ~ ~ 100 125 250 300 L10-FN400P3 4402 F1 L10-CN400P3 7064 F1 L10-KN400P3 4401 F1 30 2 3 7.5 7.5 15 20 L10-FJ030P3 847 A1 L10-CJ030P3 1217 A1 L10-KJ030P3 850 A1 60 3 10 15 15 30 50 L10-FJ060P3 1053 B1 L10-CJ060P3 1398 B1 L10-KJ060P3 1053 B1 Class J Fused 100 ~ 7.5 ~ 30 60 75 L10-FJ100P3 1433 C1 L10-CJ100P3 2629 C1 L10-KJ100P3 1433 C1 200 ~ 10 ~ 60 125 150 L10-FJ200P3 2390 D1 L10-CJ200P3 3695 D1 L10-KJ200P3 2389 D1 400 ~ ~ 100 125 250 300 L10-FJ400P3 4402 F1 L10-CJ400P3 7064 F1 L10-KJ400P3 4401 F1 NOTE: All Enclosed Disconnects come standard with a black handle with ON/OFF marking. For a yellow and red handle, add suffix “E” to the end of the catalog number. Example: change L10FN030P3 to L10-FN030P3E. SSNA9000 L10 Disconnect Switches L L50 Discount Schedule B-7 Technical Information Series L10 Disconnect Switches Fused Disconnect Switches for CSA HRCI-J and UL Class Fuses ➊ L10NJ030P3 L10NJ060P3 L10NJ100P3 L10NJ200P3 L10NJ400P3 HRCI-J/ Class J 60 HRCI-J/ Class J 100 HRCI-J/ Class J 200 HRCI-J/ Class J 400 Electrical Ratings Standards and Approvals (see page L32) CSA Fuse Type/UL Fuse Type Maximum Fuse Cartridge Size [A] HRCI-J/ Class J 30 Maximum Voltage AC DC Ampere Rating [V] [V] [A] 600 250 30 600 250 60 600 250 100 600 250 200 600 250 400 [kA] 100 100 100 100 100 Max. Short Circuit Prospective Fault Current Fuse Operating Characteristics Time Delay Non-time Delay Time Delay Non-time Delay Time Delay Non-time Delay Time Delay Non-time Delay Time Delay Non-time Delay Maximum HP 3∅ AC 1∅ AC DC 200V, 60Hz 240V, 60Hz 460V, 60Hz 600V, 60Hz [HP] [HP] [HP] [HP] 7.5 7.5 15 20 3 3 5 7.5 15 15 30 50 7.5 7.5 15 15 ~ 30 60 75 ~ 15 25 30 50 60 125 150 25 25 50 60 100 125 250 300 50 50 100 125 120V, 60Hz 240V, 60Hz [HP] [HP] 2 3 0.5 1.5 3 10 1.5 3 ~ 7.5 ~ 7.5 ~ 10 ~ 10 ~ ~ ~ ~ 125V DC 250V DC [HP] [HP] 3 5 2 5 5 10 5 10 ~ 20 ~ 20 ~ 40 ~ 40 ~ 50 ~ 50 Mechanical Ratings IP00 IP00 IP00 IP00 IP20 10,000 IP20 10,000 IP20 10,000 IP20 8,000 IP20 8,000 4 35 4 35 17.5 155 20.3 180 31.4 275 [mm2] [AWG] [mm2] [AWG] 2.5…6 #14…#8 2.5…4 #14…#12 2.5…25 #14…#4 2.5…4 #14…#12 2.5…35 #14…#2 2.5…4 #14…#12 16…20 #6…250MCM 2.5…4 #14…#12 Two 50…150 Two 1/0…350MCM 2.5…4 #14…#12 [kg.] [lbs.] 4 0.92 2.03 4 1.32 2.9 8 4.12 9.08 8 6.16 13.59 8 13.83 30.50 [mm] [in.] 248 9 3/4 248 9 3/4 330 13 560 22 762 30 Width [mm] [in.] 171 6 3/4 197 7 3/4 301 11 27/32 344 13 17/32 424 16 45/64 Depth [mm] [in.] 148 5 13/16 148 5 13/16 162 6 3/8 178 7 243 9 9/16 Handle Mechanism Operating Torque (max.) Terminal Capacity ➌ Power terminals Auxiliary contact terminals [operations] [Nm] [Lb.-In.] Maximum number of auxiliary contact blocks Approximate Weight SSNA9000 Minimum Enclosure Size Height ➊Only CSA Certified HRCI-J and UL Listed Class J fuses are suitable for use with these disconnect switches. ➋Based on Rockwell Automation tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL98. ➌See L10 Power Wire Installation on page L58.1 for power terminal torque ratings. Discount Schedule B-7 L51 L Disconnect Switches IP00 L10 Degree of Protection (per IEC 947) Switch only Switch with Terminal Shields and Fuse Cover(s) Mechanical Endurance ➋ Technical Information Series L10 Disconnect Switches Fused Disconnect Switches for CSA HRCII-C Fuses L10NA200P3 L10NA300P3 L10NH100P3 L10NH200P3 L10NH400P3 [A] [V] [A] HRCII-C 30 600 30 HRCII-C 60 600 60 HRCII-C 100 600 100 HRCII-C 200 600 200 HRCII-C 400 600 400 [kA] 100 100 100 100 100 200V, 60Hz 230V, 60Hz 460V, 60Hz 575V, 60Hz [HP] [HP] [HP] [HP] 7.5 7.5 15 20 15 15 30 50 25 30 60 75 50 60 125 150 100 125 250 300 115V, 60Hz 230V, 60Hz [HP] [HP] 2 3 3 10 – 15 – 30 – 50 IP00 IP00 IP00 IP00 IP00 IP20 10,000 4 35 IP20 10,000 4 35 IP20 10,000 20.3 180 IP20 8,000 31.4 275 IP20 8,000 31.4 275 [kg.] [lbs.] 2.5…6 #14…#8 2.5…4 #14…#12 4 0.83 1.84 2.5…25 #14…#4 2.5…4 #14…#12 4 1.18 2.60 10…50 #8…#1/0 2.5…4 #14…#12 4 6.16 13.59 25…240 #4…500MCM 2.5…4 #14…#12 4 9.30 20.50 Two 50…150 Two 1/0…350MCM 2.5…4 #14…#12 4 13.83 30.50 Height [mm] [in.] 248 9 3/4 248 9 3/4 384 15 1/8 610 24 762 30 Width [mm] [in.] 171 6 3/4 197 7 3/4 344 13 17/32 394 15 33/64 424 16 45/64 Depth [mm] [in.] 148 5 13/16 148 5 13/16 178 7 227 8 15/16 243 9 9/16 Electrical Ratings Standards and Approvals (see page L32) CSA Fuse Type Maximum Fuse Cartridge Size Maximum Voltage - AC Ampere Rating Max. Short Circuit Prospective Fault Current Maximum HP 3∅ AC 1∅ AC Mechanical Ratings Degree of Protection (per IEC 947) Switch only Switch with Terminal Shields and Fuse Cover(s) Mechanical Endurance ➊ [operations] [Nm] Handle Mechanism Operating Torque (max.) [Lb.-In.] Terminal Capacity ➋ Power terminals Auxiliary contact terminals [mm2] [AWG] [mm2] [AWG] Max. number of auxiliary contact blocks Approximate Weight Minimum Enclosure Size ➊Based on Sprecher+Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4 and IEC 947-3. ➋See L10 Power Wire Installation on page L58.1 for power terminal torque ratings. L52 Discount Schedule B-7 SSNA9000 L10 Disconnect Switches L Technical Information Series L10 Disconnect Switches Non-Fused Disconnect Switches for CSA and UL Class Applications ➊ L10NN030P3 L10NN060P3 L10NN100P3 L10NN200P3 L10NN400P3 [A] 30 ➋ 60 ➋ 100 ➋ 200 ➋ 400 ➋ [V] [V] [A] 600 250 30 600 250 60 600 250 100 600 250 200 600 250 400 [kA] 100 100 100 100 100 Electrical Ratings Standards and Approvals (see page L32) Maximum Fuse Cartridge Size Maximum Voltage AC DC Ampere Rating Max. Short Circuit Prospective Fault Current Fuse Operating Characteristics Time Non-time Delay Time Non-time Delay Time Non-time Delay Time Non-time Delay Time Non-time Delay Maximum HP 200V, 60Hz 230V, 60Hz 460V, 60Hz 575V, 60Hz [HP] [HP] [HP] [HP] 7.5 7.5 15 20 3 3 5 7.5 15 15 30 50 7.5 7.5 15 15 25 30 60 75 15 15 25 30 50 60 125 150 25 25 50 60 100 125 250 300 50 50 100 125 1∅ AC 115V, 60Hz 230V, 60Hz [HP] [HP] 2 3 0.5 1.5 3 10 1.5 3 7.5 15 – 7.5 – 25 – 15 – 50 – 25 DC 125V DC 250V DC [HP] [HP] 3 5 2 5 5 10 5 10 – 20 – 20 – 40 – 40 – 50 – 50 3∅ AC Mechanical Ratings IP20 IP00 IP00 IP00 IP20 ➍ 10,000 4 35 IP20 ➍ 10,000 4 35 IP20 10,000 17.5 155 IP20 8,000 20.3 180 IP20 8,000 31.4 275 [kg.] [lbs.] 2.5…6 #14…#8 2.5…4 #14…#12 4 0.81 1.78 2.5…25 #14…#4 2.5…4 #14…#12 4 1.14 2.52 2.5…35 #14…#2 2.5…4 #14…#12 4 4.31 9.50 16…120 #6…250MCM 2.5…4 #14…#12 4 6.56 14.47 Two 50…150 Two 1/0…350MCM 2.5…4 #14…#12 4 14.97 33.00 [mm] [in.] 248 9 3/4 248 9 3/4 330 13 560 22 762 30 Width [mm] [in.] 171 6 3/4 197 7 3/4 301 11 27/32 344 13 17/32 424 16 45/64 Depth [mm] [in.] 111 4 3/8 111 4 3/8 162 6 3/8 178 7 243 9 9/16 Terminal Capacity ➎ Power terminals Auxiliary contact terminals Max. number of auxiliary contact blocks Approximate Weight SSNA9000 Minimum Enclosure Size Height [operations] [Nm] [Lb.-In.] [mm2] [AWG] [mm2] [AWG] ➊Non-fused disconnects must use separately installed CSA Certified HRCI-J, HRCI-T or HRCI-MISC (also UL Listed as Class CC) fuses; or UL Listed Class J, CC or T fuses. ➋When using CSA HRCI-J, HRCI-MISC (also UL Listed as Class CC) or HRCI-T fuses, and UL Class J, CC or T fuses. ➌Based on Sprecher + Schuh tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL98. ➍Line and load terminal shields supplied as standard. ➎See L10 Power Wire Installation on page L58.1 for power terminal torque ratings. Discount Schedule B-7 L53 L Disconnect Switches IP20 L10 Degree of Protection (per IEC 947) Switch only Switch with Terminal Shields and Fuse Cover(s) Mechanical Endurance ➌ Handle Mechanism Operating Torque (max.) Technical Information Series L10 Disconnect Switches Environmental Data For All L10 Fused and Non-Fused Disconnect Switches All L10 Fused and Non-Fused Disconnect Switches Environmental Ratings Ambient Temperature Open Enclosed Storage Altitude (per IEC 947-1) Relative Humidity (per IEC 947-1) [°C (F)] [°C (F)] [°C (F)] [m] –2…+55 (–4…+131) –20…+40 (–4…+104) –40…+65 (–40…+149) 2,000 90% at +20°C (+68°F) 50% at +40°C (+104°F) Auxiliary Contact Ratings All L10 Auxiliary Contacts AC-11 Rating Volts Ue 12…120 220…240 380…480 500…600 Thermal Current EEMAC/NEMA A600, P300 Insulation Voltage - IEC Ui [A] [V] Volts Ue 28 110 220 440 600 Amps Ie 5.0 1.25 0.62 0.27 0.20 10 660 -OLDED #ASE .%-!TYPE #ATALOG .UMBER .* .! .. .* .( .. 5, -ISCELLANEOUS 3WITCH .O 9ES 5, -OLDED #ASE 9ES .O #3! 9ES 9ES #% 9ES .O Conformity to Standards: IEC 947-3/EN60947-3 Low voltage switchgear and control gear part 3: Switches, disconnectors, switchdisconnectors and fuse-combination units. CE BS EN60947-3 VDE 0660 CSA 22.2 No. 4 NEMA KS-1 UL 1087 UL 98 SSNA9000 L10 Disconnect Switches L Approvals: UL Listed File Nos. E191715 E191716 E191717 E191718 E193035 CSA Certified File No. LR 113426-1 CE Marked Per IEC 947-3 Meets IEC, VDE and BS standard requirements LOVAG Certified ASTA Certified DC-11 Rating Amps Ie 6 3 1.5 1.2 L54 Discount Schedule B-7 Application Methods Series L10 Disconnect Switches Applications Within the United States and Canada Load HP Full-Load Current A Motor 1 5 7.6 (simultaneous) Motor 2 10 14.0 (not included) ➊ Motor 3 15 21.0 (simultaneous) Motor 4 20 27.0 (simultaneous) Other 7.0 (simultaneous) Total Equivalent 62.6 (simultaneous) Single Motor Applications Section 430-110 Paragraph (a) states that the disconnect switch must have an ampere rating of at least 115% of the full load current rating of the motor. ➊Motor 2 is not included in the total since it cannot operate simultaneously with the other motor, therefore, the disconnect switch must be rated at least 72A (1.15 x 62.6). Example 1: for a motor with a full-load current of 22A, the disconnect switch must be rated at least 25.3A (22 x 1.15). Consider now the locked-rotor current analysis for the same application: If the disconnecting means under evaluation is rated in horsepower, the selection of the disconnect switch is even more straightforward; a disconnect switch must have a horsepower rating equal to, or greater than the horsepower rating of the motor at the applicable voltage. Load HP Locked Rotor Current A 5 Motor 2 10 84.0 (not included) ➊ Example 2: For a motor with a 10HP rating at 460V AC, the disconnect switch must be rated at least 10HP at 460V AC. Motor 3 15 126.0 (simultaneous) ➋ Motor 4 20 162.0 (simultaneous) ➋ If the disconnect switch is rated in horsepower, and UL Listed, UL Component Recognized, or CSA Certified, it will meet the requirements for the 115% full-load current rating stipulated by the NEC. Other The individual full-load current values are to be selected from Tables 430-148, 430-149, or 430-150 and the locked-rotor values are to be from Table 430-151. The equivalent single motor full-load current is the sum of the simultaneously operating motor full-load currents and the rating in amperes of the other loads operating at the same time. The equivalent locked-rotor current is the sum of the simultaneously started motors’ locked-rotor currents and the full-load currents of the remaining operating motor and non-motor loads. Total Equivalent (7.6 FLA) 45.6 (simultaneous) Motor 1 Combination Load Applications Section 430-110 Paragraph (c) addresses the rating of the disconnecting means for combination loads. This paragraph essentially requires that the loads that “may be simultaneously on a single disconnecting means” be combined to provide equivalent full-load and locked-rotor currents for what is then to be considered as a single motor for the purpose of selecting the appropriate disconnecting means. This means that it is necessary to identify the particular combination of connected loads which can be operating simultaneously and will result in the maximum full-load and locked-rotor current sums. SSNA9000 Consider the following 460V application: 7.0 (simultaneous) 302.6 (simultaneous) ➊Note again that Motor 2 cannot operate simultaneously with the other loads. ➋The largest equivalent locked-rotor current occurs when motors 3 and 4 start together while the other loads marked “simultaneous” are already operating. Since Motor 1 is not starting with Motors 3 and 4, its full-load current will be added to the total instead of its locked-rotor current. Table 430-151, which provides the correlation between locked-rotor currents and HP ratings, shows that a 40 HP rating is the equivalent for 302.6 locked-rotor amperes. Therefore, the disconnect selected for this application must have a current rating of at least 72A and a HP rating of at least 40 HP. In this case, an L10 disconnect switch rated for 100A and 60 HP at 460V would be an appropriate choice. What can be seen from this analysis is that, depending upon the number of motors that can start simultaneously, the actual size of the required disconnect is sometimes determined by the equivalent full load current (72A) and other times by the equivalent horsepower determined from the locked-rotor analysis (40 HP). Discount Schedule B-7 L55 L Disconnect Switches The requirements for properly sizing a disconnect switch are dependent on the type of application. The NEC refers to two types of applications: single motor and combination loads. A combination load consists of an application where two or more motors are used together or where one or more motors are used in combination with other loads, such as resistance heaters. The disconnecting means shall have a current rating equal to or greater then 115% of the equivalent single motor full-load current and have a horsepower rating equal to or greater than the horsepower rating determined from the equivalent locked-rotor summation. L10 General The requirements for disconnect switches used in motor branch circuits rated 600V and less are defined in Article 430, Part H of the U.S. National Electrical Code (NEC), NFPA70. Canadian Electrical Code (CEC) requirements are very similar in the area of motor branch circuit disconnect requirements. For simplicity, we will treat the NEC and CEC requirements as being the same – and reference specific sections of the US National Electrical Code. Technical Information IP Ratings Definitions IP Ratings Definitions IP Ratings Definitions The first IP number (left side of chart) is protection against solid objects. The second IP number (across top) is protection against liquids. The chart itself shows degrees of protection according to IEC 529. 1 meter No protection IP…0 Protected against vertically falling drops of water (condensation) Protected against dripping water with enclosure up to 15° from vertical Protected against sprayed water up to 60° from vertical Protected against sprayed water from all directions (limited ingress permitted) Protected against low pressure water jets from all directions (limited ingress permitted) Protected against strong jets of water from all directions Protected against immersion up to one meter Protected against long periods of immersion under pressure IP…3 IP…4 IP…5 IP…6 IP…7 IP…8 IP55 IP56 IP65 IP66 IP…1 IP…2 IP10 IP11 IP12 IP20 IP21 IP22 IP23 IP30 IP31 IP32 IP33 IP34 IP40 IP41 IP42 IP43 IP44 IP53 IP54 IP0… IP00 No protection IP1… Protected against solid objects up to 50mm (accidental touch by hands) IP2… Protected against solid objects up to 12mm (fingers, knuckles) IP3… Protected against solid objects up to 2.5mm (tools, wires) Protected against solid objects up to 1mm (wires) IP5… L10 IP50 Protected against dust (limited engress permitted) IP6… IP60 Totally protected against dust L56 IP67 SSNA9000 Disconnect Switches L IP4… Discount Schedule B-7 Technical Information Ratings Definitions NEMA / UL Type Definitions NEMA / UL Type Indoor Use Outdoor Use Indoor or Outdoor Use For a degree of protection against: 1 12 13 3R 3 4 4X 6P 6 Incidental contact with enclosed equipment • • • • • • • • • Falling dirt • • • • • • • • • Rust • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Circulating dust, lint, fibers and flyings Windblown dust Falling liquids and light splashing Rain (limited water allowed inside) • Rain (no water allowed inside) Snow and sleet • Hosedown and splashing water Occasional prolonged submersion Oil or coolant spraying or splashing • Corrosive agents • Occasional temporary submersion • • • SSNA9000 L10 Disconnect Switches L Discount Schedule B-7 L57 Dimensions Series L10 Disconnect Switches L10 Disconnect Switch (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Disconnect Switch Approximate Dimensions Dimension Reference H 106 A1 (4 11/64) 106 (4 11/64) 118 (4 21/32) 118 (4 21/32) A2 B1 B2 W 102 (4 1/64) 102 (4 1/64) 134 (5 9/32) 134 (5 9/32) D 112 (4 13/32) 83 (3 17/64) 115 (4 33/64) 83 (3 17/64) A 82 (3 15/64) 82 (3 15/64) 100 (3 15/16) 100 (3 15/16) B 85 (3 11/32) 82 (3 15/64) 120 (4 23/32) 120 (4 23/32) FD 2-M4 2-#8 2-M4 2-#8 4-M4 4-#8 4-M4 4-#8 L10 Disconnect Switch (100, 200 & 400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. Disconnect Switch Dimension Reference H W C1 148 194 D1 E1 F1 L58 (5 53/64) 184 (7 1/4) 220 (8 21/32) 250 (9 27/32) (7 41/64) 236 (9 19/64) 278 (10 15/16) 308 (12 1/8) Approximate Dimensions D A 130 (5 7/64) 148 (5 53/64) 180 (7 3/32) 213 (8 25/64) 106 (4 11/64) 106 (4 11/64) 150 (5 29/32) 150 (5 29/32) Discount Schedule B-7 B FD 170 4-M6 (4 1/4) 4-M6 (4 1/4) 4-M8 (4 5/16) 4-M8 (4 5/16) (6 11/16) 212 (8 11/32) 252 (9 59/64) 282 (11 7/64) SSNA9000 L10 Disconnect Switches L Dimensions Series L10 Disconnect Switches L10 Power Wire Installation Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. L10-NH100P3 -NH200P3 -NJ200P3 -NN200P3 -NA400P3 -NH400P3 -NJ400P3 -NN400P3 D L10-NJ100P3 -NN100P3 C D1 D2 E1 F1 L10-LE1 L10-LF1 L10-LF1 L10-LF1 L10-LG1 L10-LH1 B C D #AWG N¥m lb-in N¥m lb-in 14-2 4.0 35 ~ ~ 8-1/0 16.9 150 16.9 150 6-4/0 31 275 31 275 6-4/0 31 275 31 275 #4-500MCM 42 375 45 400 (2) 1/0-350MCM 31 275 45 400 mm2 2.5-35 10-50 16-120 16-120 25-240 (2) 50-150 ON A C OFF Dimension Reference C1, C2 L10-NH100P3 -NH200P3 -NJ200P3 -NN200P3 -NA400P3 -NH400P3 -NJ400P3 -NN400P3 A B L10 Fuse Installation L10-NH100P3 -NJ100P3 -NJ200P3 -NA400P3 L10-NH200P3 -NJ400P3 -NH400P3 A L lb-in 35 35 55 55 140 140 200 SSNA9000 L10-NJ100P3 L10-NJ200P3 L10-NH100P3 L10-NA400P3 L10-NH200P3 L10-NH400P3 L10-NJ400P3 A N¥m 4.0 4.0 6.2 6.2 16 16 22 L10 Catalog Number Disconnect Switches A Discount Schedule B-7 L58.1 Dimensions Series L10 Disconnect Switches L10-HS… (Type R) Switch Handle Assembly Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. ON 76.2 mm 8.8 O F F 18.4 76.2 mm 40.3 65.1 25 50 25 Ø 5.5mm Ø 35 50 L10-HM… Pistol Grip Switch Handle Assembly Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 75 (2-61/64) 37.5 (1-15/32) 65 (2-9/16 dia.) L10 75 (2-61/64) SSNA9000 4 – 5.5 (4 7/32 dia.) Discount Schedule B-7 Disconnect Switches L 37.5 (1-15/32) L59 Dimensions Series L10 Disconnect Switches Type 3/4/12 - Watertight, Dusttight Sheet Metal Enclosure (30, 60 & 100A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. D Amps 30 60 100 Type Dim. Ref. Fused & Non-fused Fused & Non-fused Fused & Non-fused A1, A2 B1, B2 C1 A B C D E F G H 305 (12.00) 305 (12.00) 406 (16.00) 305 (12.00) 305 (12.00) 406 (16.00) 173 (6.80) 173 (6.80) 224 (8.80) 213 (8.39) 213 (8.39) 282 (11.10) 267 (10.5) 267 (10.5) 368 (14.5) 267 (10.5) 267 (10.5) 368 (14.5) 76 265 (3) (10-7/16) 76 265 (3) (10-7/16) 178 315 (7) (12-25/64) Type 3/4/12 - Watertight, Dusttight Sheet Metal Enclosure (200 & 400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. L10 Disconnect Switches L Type Dim. Ref. A B 200 Fused & Non-Fused Fused & Non-Fused D1 406 610 224 282 688 650 368 572 (16) (24) (8-51/64) (11-5/64) (27-5/64) (25-9/16) (13-31/64) (22-1/2) F1 610 762 326 384 840 802 572 724 (24) (30) (12-51/64) (15-5/64) (33-5/64) (31-9/16) (22-1/2) (28-1/2) 400 L60 C Discount Schedule B-7 D E F G H SSNA9000 Amps Dimensions Series L10 Disconnect Switches Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (30, 60 &100A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. D Amps 30 60 100 Type Fused & Non-fused Fused & Non-fused Fused & Non-fused Dim. Ref. A1, A2 B1, B2 C1 A B C D E F G H 305 (12.00) 305 (12.00) 406 (16.00) 305 (12.00) 305 (12.00) 406 (16.00) 173 (6.80) 173 (6.80) 224 (8.80) 213 (8.39) 213 (8.39) 282 (11.10) 267 (10.5) 267 (10.5) 368 (14.5) 267 (10.5) 267 (10.5) 368 (14.5) 76 265 (3) (10-7/16) 76 265 (3) (10-7/16) 178 315 (7) (12-25/64) Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure (200 & 400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. SSNA9000 L10 Disconnect Switches L Amps Type Dim. Ref. A B C D E F G H 200 Fused & Non-Fused Fused & Non-Fused D1 406 610 224 282 688 650 368 572 (16) (24) (8-51/64) (11-5/64) (27-5/64) (25-19/32) (14-1/2) (22-1/2) F1 610 762 326 384 840 802 572 724 (24) (30) (12-51/64) (15-5/64) (33-5/64) (31-15/32) (22-1/2) (28-1/2) 400 Discount Schedule B-7 L61 Dimensions Series L10 Disconnect Switches Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (30 & 60A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 5.5 (15/64) A H D C J F B (4)- 8 X 13 SLOT MTG. HOLES (11/32) (17/32) G 32 (1-1/4) Amps Type Dim. Ref. A B C D F G H J 30 & 60 Fused & Non-Fused A1 & A2 B1 & B2 226 267 163 203 278 152 216 305 K 6 (8-59/64) (10-33/64) (6-27/64) (7-31/32) (10-61/64) (6) (8-1/2) (12) (15/64) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (100A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 5 (3/16) A H D C Disconnect Switches L F B L10 J G 32 (1-9/32) (4)- 8 X 13 SLOT MTG. HOLES (11/32) (17/32) Type Dim. Ref. A B C D F G H J 100 Fused & Non-Fused C1 380 420 215 273 430 305 370 457 5 (14-31/32) (16-1/4) (8-31/64) (10-49/64) (16-61/64) (12) (14-9/16) (18) (13/64) L62 Discount Schedule B-7 K SSNA9000 Amps Dimensions Series L10 Disconnect Switches Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (200A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 11.5 (29/64) F D A C B J (4)- 10 DIA. MTG. HOLES (13/32) G Amps Type Dim. Ref. A B C D F G J K 200 Fused & Non-Fused D1 513 625 292 350 648 457 686 11.5 (20-13/64) (24-5/8) (11-31/64) (13-25/32) (25-1/2) (18) (27) (29/64) Type 3/4/4X/12 - Corrosion Resistant Non-Metallic Enclosure (400A) Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. K 10.5 (27/64) D C A B J L10 F Disconnect Switches L SSNA9000 57mm (2-1/4") (4)- 10 DIA. MTG. HOLES (13/32") G Amps Type Dim. Ref. A B C D F G J K 400 Fused & Non-Fused F1 612 (24 1/8) 775 (30 33/64) 343 (13 31/64) 401 (15 23/32) 796 (31 31/32) 555 (21 7/8) 834 (32 27/32) 10.5 Discount Schedule B-7 (13/32) L63 Disconnect Switches Series L10 Notes SSNA9000 L10 Disconnect Switches L L64 Discount Schedule B-7