NC-DSP-A - Crest Audio

advertisement
Power
Processing
Modules
INPUT PROCESSING MODULE
FOR CKS, CKV & CKX SERIES
POWER PROCESSING AMPLIFIERS
NC-DSP-A
Digital Signal Processor (DSP) with Analog Inputs
Product Information
Input sensitivity is selectable for 10 dBU or 20 dBU. Individual channel
attenuators are provided with removable knobs for extra security.
The NC-DSP-A Module fits in the Input Processing bay located on the
rear panel of Crest Audio CKS, CKV & CKX Series Power Processing
amplifiers. It provides state-of-the-art digital signal processing integrated with the amplifier channel. It is identical in operation to the NC-DSPD but adds ADC converters, allowing analog audio to be digitally
processed. Two post-processing analog outputs are provided to daisy
chain out to additional amp channels requiring the same processing.
Via NexSys® or N-Coder/PC software, algorithms are down-loaded to
the NC-DSP-A to perform crossover, equalizing, driver alignment, system delay, limiting, compression, gating functions, etc. All the requirements for loudspeaker processing can be performed by the NC-DSP-A.
Features:
• Digital signal processing and attenuation programmed by NexSys or N-Coder/PC software.
• Post-processing loop-thru outputs on barrier strip connectors
• Crossover, EQ, delay, and dynamics functions
• Two delays are equivalent to 600 feet (183 meters) each
• Amp channel gain pot knobs removable for security
• Simple setup, tamper-proof configuration
• Balanced input barrier strip connectors
• Can be used stand-alone after being programmed
• Selectable input sensitivity of 10 dBU or 20 dBU
NC-DSP-A connections
N-Coder
Crest Audio
Revision 1.03E
OR
PC Lap-Top running
N-Coder/PC software
To other amplifiers
Designed & manufactured in the USA by:
CLASS 2
WIRING MAY
BE USED
Output
–
A
+
+
Crest Audio Inc.
100 Eisenhower Dr.
Paramus, New Jersey 07652 USA
Model
Name
Output Power
@70.7V
Model
Name
Output Power
@8Ω/Ch.
CKV 100
CKV 200
CKV 400
CKV 800
CKV 1600
CKV 2400
50W
100W
200W
400W
800W
1200W
CKS 100
CKS 200
CKS 400
CKS 800
CKS 800-2
CKS 1200-2
CKS 1600-2
50W
100W
200W
400W
400W
600W
800W
Daisy Chain
Level
4 5 6
A 3
7
N-Coder
Data
Port
2
1
0
A
B
B
Network
Address
F
0
8
9
10
F
DCBA
9 8 7 6
Hi
2
1
E
+ –
DCBA
+ –
1
E
5 4 3 2
1
Level
4 5 6
B 3
7
Input B
Input A
Model
NC-NXS
5 4 3 2
Data
Signal
Ground
Lift
Jumper
9 8 7 6
–
8
9
10
Lo
+
–
+
–
Model
NC-DSP-A
NexSys Bus
Input
Signal A
Architects and Engineers Specifications - NC-DSP-A.
The module shall plug into Crest Audio CKS or CKV Power Processing amplifiers in the
Input Processing bay. The module shall provide full DSP (digital signal processing) functions. Capabilities for EQ, cross-over filters, delay, dynamics control, etc. are achievable
with Nexsys software modules The module shall be capable of being programmed and
updated over the NexSys network (if fitted in a CKS or CKV amplifier loaded with an NCNXS module and NexSys-compatible Power/Output module). The module shall operate as a
Input
Signal B
stand-alone unit after being programmed with the N-Coder/PC software. The audio inputs
shall consist of two balanced analog inputs on a barrier strip connector. Two, post-processing, analog outputs on barrier strip connectors shall be provided to loop-thru out to additional amp channels requiring the same processing. Two removable-knob gain pots shall be provided that control the level of each amplifier channel independent of programming. Input
sensitivity shall be selectable for either 10dBU or 20dBU. The module shall be designated
the Crest Audio model NC-DSP-A.
NC-DSP-A
Input Processing Module
Digital Signal Processor (DSP) with Analog Inputs
BLOCK
DIAGRAM
CH A OUT
Daisy Chain
CH B OUT
Vosc
For LM
Delay
MEM
CH A
+
G
CH B
DAC
DSP
+
G
I/F
ckt
Internal digital signal processing:
24-bit
Analog-to-digital converters:
18-bit
Digital-to-analog converters:
18-bit
Max input level:
+22dBu
Dynamic range:
100dB
Signal-to-noise ratio:
100dB
0.005%
Frequency response:
Common mode rejection:
Selectable input sensitivity:
CH B
Power
Amp
NexSys
Module Bus
The following NC-DSP-A parameters can be controlled by N-Coder/PC software or via NexSys
software.
N-Coder/PC software:
Channel A & B attenuation, phase reverse, muting,
all DSP functions*.
NexSys computer control:
Channel A & B attenuation, phase reverse, solo,
muting, input and output VU metering; all DSP
functions*.
20Hz-20kHz
100dB
10 dBU
20dBU
Connectors:
Balanced inputs and unbalanced
loop-thru daisy-chain outputs on barrier strips
with 0.325" (8mm) center & 0.27" (7mm) lug space,
RJ-14 (‘RJ-11 6-pin’) N-Coder data port
Controls:
Atten
CONTROL OPTIONS
S P E C I F I C AT I O N S
THD:
CH A
Power
Amp
DAC
ID
N-Coder
Data Port
Atten
*DSP Programs: Stereo BP, HP and LP
crossovers, mono BP/BP, BP/HP, LP/BP, and
LP/HP crossovers, dual mono 5-band EQ
*DSP Algorithms: Mixer, shelf, 4 and 5-band
parametric EQ, long delay, bandpass crossover, 4band parametric post EQ, short delay, limiter, gain
2 gain attenuators (w/removable knobs)
Crest Audio reserves the right to make improvements in manufacturing or design which may affect specification. Crest Audio specification literature is available in electronic form to qualified users.
Contact Crest Audio Inc. for more information. NexSys is a registered trademark of Crest Audio Inc. ©1996 Crest Audio Inc.
Crest Audio Inc.
100 Eisenhower Dr., Paramus NJ 07652 USA
TEL: 201.909.8700 FAX: 201.909.8744
http://www.crestaudio.com
*A3300021*
v. 2.1
4/7/97
Printed in USA
Download