INDC – Cubic Indirect
TYPE
• Hidden MR16 lamp in wall mount provides code-required emergency path of egress illumination
• Round or square upper reflectors available
• Integral ballast assembly in fixture for easy installation
• Uses the Indirect Reflector System for IES cutoff classification
• Tool-less access to integral ballast assembly
• IP 66 rating
• Lightweight aluminum composite upper reflector minimizes pole stress
• Powder coat finish in 13 standard colors with a polymer primer sealer
• Reflector tilts and locks at 0, 15 or 30 degrees
1. LUMINAIRE 2. REFLECTOR-UPPER 3. LAMP/BALLAST 4. COLOR
1.
LUMINAIRE
INDC
Square straight, fixed head.
2. REFLECTOR – UPPER
RD (30" round upper reflector)
SQ (30" square upper reflector)
SQ
RD
3.LAMP/BALLAST
LED (30 light emitting diode array, 33 watts. Warm white (3000K),
Neutral white (4000K), Bright white (5000K), 120 thru 277 volt)
30LED-WW (Warm white)
30LED-NW (Neutral white)
30LED-BW (Bright white)
COMPACT FLUORESCENT (GE F70QBX lamp. -10°C min
start temp)
CF
METAL HALIDE (120/208/240/277 volt ballast)
Medium base, ED-17 lamp
70MH 100MH
G12 base, T-6 ceramic lamp
70MHT6
GX8.5 base, R111 lamp 70R111
ELECTRONIC METAL HALIDE (120 thru 277 volt ballast)
Medium base, ED-17 lamp
150MHEB
70MHEB G12 base, T-6 ceramic lamp
150MHT6EB
70MHT6EB GX8.5 base, R111 lamp 70R111EB
PULSE START METAL HALIDE (120/208/240/277 volt
ballast)
Medium base, ED-17 lamp
150PSMH
G12 base, T-6 ceramic lamp
150PSMHT6
5. OPTIONS
INDC
SPECIFICATIONS
4. COLOR
WH Arctic White
BL Black
BLT Matte Black
DB Dark Bronze
DGN Dark Green
TT Titanium
WDB Weathered Bronze
MDB Bronze Metallic
6. MOUNTING
VBU Verde Blue
CRT Corten
MAL Matte Aluminum
MG Medium Grey
AGN Antique Green
LG Light Grey
RAL Premium Color
CUSTOM * * Contact Factory
5.OPTIONS
CDC (Center deflector cone for round reflector. Provides a wider light
distribution)
SR (Two aluminum rings attached to the fixture. Factory installed)
CFH (Color filter holder attached to the fixture includes solid rings.
Factory installed)
LAMP R111 (70 watt metal halide R111 reflector lamp)
SCP (Sensor Control Programmable) pole accessory is
available to provide occupancy detection for outdoor
applications meeting California Title 24. For complete
spec sheet and ordering information, visit www.aal.net/
products/sensor_control_programmable/
6. MOUNTING – Must choose one
WALL MOUNT
WMA2 (10 lbs. Features built in MR16 egress (50 watt))
WMA2-NEG (10 lbs. No egress lamp. Blocked opening
POLE MOUNT
PMAT2 (Twin arm, slips over a 4"/100mm O.D. pole or tenon)
PTS5 (Post top mount slips over a 2 3/8" O.D. round tenon 5"/127mm square pole)
PTS4 (Post top mount slips over a 4"/100mm square pole)
Visit www.aal.net for Arms, Poles & Accessories
Specification Guide
UPPER REFLECTOR
The upper reflector shall be light weight aluminum
composite. The reflector shall be finished in a
white, fluoropolymer finish. The reflector shall be
attached to the cast aluminum pivot joints and
secured with four stainless steel bolts. Two cast
aluminum, adjustable knuckles shall connect the
reflector assembly to the vertical, stainless steel
struts. The struts are #316 stainless steel with a
minimum .075” wall thickness. The struts shall
be clamped in place with 5/16-18 set screws for
attachment to the upper reflector and the lamp
module.
LAMP MODULE
The reflector shall be enclosed cast aluminum
housing. The front cover is secured with four
cap screws for re-lamping and internal access.
The top glass element is clear, tempered glass.
The top cover and electrical module are sealed
with memory retentive, molded silicone gaskets.
The parabolic reflector shall be pre-focused to
illuminate the upper reflector with no stray light
beyond the reflector. All internal and external
hardware is stainless steel.
HOUSING
The post top model shall slip over a 4"/100mm
pole on a 2 3/8" O.D. tenon or a 5"/127mm square
pole.
SAFETY
The wall mounted luminaire (WMA-2) includes
an integral secondary source to provide coderequired 1 footcandle emergency path-of-egress
illumination from building to the public way. The
hidden MR16 lamp, powered as a remote head, is
able to be angled up to 15° in either direction.
ELECTRICAL MODULE
The ballast is mounted on a pre-wired plate with
a quick disconnect plug. Magnetic metal halide
ballasts are high power factor, rated for -30°C
starting. Electronic metal halide ballasts are rated
for -30°C starting, sound rating A, 120 thru 277
volt. Sockets are pulse rated porcelain for medium
base ED-17; bi-pin, G12 for T-6 lamps; GX8.5
for R111. The compact fluorescent shall have an
electronic transformer, 120 thru 277 volt.
All ballasts are factory wired for 277 volts. Lamps not included (except
LED options).
See next page
JOB
TYPE
ARCHITECTURAL AREA LIGHTING
16555 East Gale Ave. | City of Industry | CA 91745
P 626.968.5666 | F 626.369.2695 | www.aal.net
Copyright © 2012 | REV 10.15
NOTES
| 1 |
FILENAME: INDC-RD-150MH.IES
IESNA:LM-63-2002
[TEST] 24270
[TESTLAB] LIGHTING SCIENCES, INC.
[ISSUEDATE] 01/06/09
[TESTDATE]
9/30/2008
TYPE
[MANUFAC] ARCHITECTURAL AREA LIGHTING
[LUMCAT] INDC-RD-150MH OR HEB
[LUMINAIRE] CUBIC INDIRECT AJUSTABLE POST TOP LUMINAIRE;
[MORE] UPPER REFLECTOR WHITE, LOWER REFLECTOR
2
[MORE] SPECULAR WITH CLEAR FLAT GLASS LENS
DIMENSIONS
[LAMP] ONE PHILIPS 150 WATT MH LAMP
[LAMPCAT] MH150/U/M-PHILIPS
[OTHER]
LUMENS=12250; WITH SAIL SET AT 0 DEGREES
device
with a
INDC – Cubic Indirect
CONTROLS
SCP shall have an integral surge protection
currentt rating of 10,000 Amps using the industrySUMMARY
standardDATA
8/20uSec wave and sure rating of 372J
EFFICIENCY (Total):
EFFICIENCY (Down / Up):
Sensor not intended for use with additional photo-control,
EFFICIENCY (Street / House):
ROADWAY CLASSIFICATION:
wireless control or dimming systems
CUTOFF CLASSIFICATION:
DATE
RECORD
DESN CHCK
30"/750mm
30.0
INDC
WT: 45.9 lbs
EPA:
INDC-SQ Sail:
0° = 1.70
15° = 3.27
30° = 5.01
34.6 %B
33.5 % / 1.1 %
17.3 % / 17.3 %
TYPE V,
CUTOFF
12250
41.4"/1035mm
1
41.4
CIRCULAR
2.50 (Feet)
186
LUMENS/LAMP:
FINISH
NO. OF LAMPS:
Fixture finish consists of a five stage pretreatmentLUMINOUS
regimenOPENING:
with a polymer primer sealer, oven dry off and top coated Diameter:
INPUT WATTS:
with a thermoset super TGIC polyester powder coat
finish. The finish shall meet the AAMA 605.2 performance
CATALOG NUMBER: INDC-SQ-LED-30
specification which includes passing a 3000 hour salt
FILENAME: INDC-SQ-LED-30.IES
spray test for corrosion resistance. The reflector shall be
IESNA:LM-63-2002
painted white. The lens frame shall be painted black
to
[TEST] 24693
further control any up light. The vertical struts are[TESTLAB]
stainlessLIGHTING SCIENCES, INC.
[ISSUEDATE]
01/12/09
steel. All other fixture parts shall be finished in the
same
[TESTDATE] 01/08/09
specified color.
[MANUFAC] ARCHITECTURAL AREA LIGHTING
CERTIFICATION
The fixture shall be listed with
wet location use, UL1598 and
NO.250. IP=66
1
REV
B
24.0
24"/600mm
Photometric Report
INDC-RD Sail:
0° = 1.46
15° = 2.89
30° = 4.28
A
A
CRITICAL DIMENSIONS
This document contains confidential and proprietary information of Architectural
Area Lighting, a division of Hubbell Lighting, Inc. (HLI). Receipt or possession of
this document does not convey any rights to reproduce or disclose its contents,
or to make, use , or sell anything it may disclose. Reproduction, disclosure, or
use of the document or its contents, without the specific written authorization of
HLI, may violate the intellectual property rights of HLI.
UNSPECIFED TOLERANCES: INCHES
X.X=u0.1 X.XX=u0.03 X.XXX=u0.010
FRACTIONS=u1/32 ANGULAR TOLERANCE=u1v
DRAWN:
DIMENSIONS IN INCHES
DIMENSIONS IN [ ] IN MM
Nora
CONFORMS TO ASME Y14.5M
CHECKED BY:
08/26/08
---
DO NOT SCALE PRINT
--/--/--
ENGINEERING:
INDC-PT
MATERIAL:
FINISH:
PART NO.
----/--/-[LUMCAT] INDC-SQ-LED-30
SHT 1
- - 1 SHTS
A
[LUMINAIRE] CUBIC INDIRECT AJUSTABLE POST TOP LUMINAIRE;
2
1
[MORE]
UPPER
REFLECTOR
WHITE,
LOWER
REFLECTOR
ETL and U.L. for outdoor,
[MORE] SPECULAR WITH CLEAR FLAT GLASS LENS
INDC 150MH
WATTAGE: 186
LUMEN OUTPUT:
Canadian CSA Std.[LAMP]
C22.2
30 LED'S
ISO-ILLUMINANCE DIAGRAM (fc)
[LAMPCAT] 30 1-W LED'S RATED AT 3000 INITIAL LUMENS
[OTHER] OPERATING AT 120 VAC AND 37 WATTS WITH SAIL
Name?:Finish
SCALE
CATALOG NO.
SIZE
DRAWING NO.
-
REV.
PV:1
THIRD ANGLE PROJECTION
4241
B2 U3 G1
WARRANTY / TERMS AND CONDITIONS OF SALE
SUMMARY DATA
FORWARD LIGHT
LUMEN
Download:
10.6%% 450
EFFICIENCY (Total):
FL30 o- 102032.6
http://www.hubbelllighting.com/resources/warranty/
EFFICIENCY (Down / Up):
- 92509.4 % / - 9523.2 %
25.1%
FM60 o- 80142.5
1064 %
EFFICIENCY (Street / House):
% / - 21889.9
11.2%
FH80 oTYPE
ROADWAY CLASSIFICATION:
IV, VERY SHORT
474
CUTOFF CLASSIFICATION:
NONCUTOFF
FVH90 o-1 1.6%
67
LUMENS/LAMP:
AAL reserves the right to change product specifications withoutNO.
notice
.
OF LAMPS:
1
BACK
LIGHT
LUMINOUS OPENING:
RECTANGULAR
Width:
(Feet)
450
BL30 o2.5010.6%
Length:
o2.50
BM60 0.0025.1% 1064
Height:
o
INPUT WATTS:
BH80 37 11.2%
474
1.6%
BVH90 o
67
UPLIGHT
UL100 o
UH180 o
0.2% 2.9%
7
125
0.02 0.05
0.01
0.2
0.51.
2.
0.1
B0 U2 G1
0.01
LUMEN
87
315
234
72
6.3%
12.7%
2.2% 0.1%
64
129
22
1
UPLIGHT
UL100 o 4.4%
o
4.9%
UH180
45
50
Mounting 1.1%
UPLIGHT
Height
Multiplier
DOWNLIGHT
33.5%
-----------------------10
15
20
25
30
35
40
45
50
4.000
1.778
1.000
0.640
0.444
0.327
0.250
0.198
0.160
+ = Point of max candela
Photometric Viewer v3.4
BACK LIGHT
BL30 o
BM60 o
BH80 o
BVH90 o
EFFICACY: 22.8 Lm/W
14'
MOUNTING
Mounting
Height =HEIGHT
20 Feet. Each box represents one mounting height.
Reported data calculated
from manufacturer's
data file, based on
IESNA recommended
methods.
INDC
30LED BW
WATTAGE:
37
LUMEN OUTPUT: 1020
ISO-ILLUMINANCE DIAGRAM (fc)
FORWARD LIGHT
FL30 o 8.5%
o
30.9%
FM60 FH80 o 22.9% FVH90 o 7.1%
Wednesday, July 11, 2012
0.02
0.05
0.1
0.2
EFFICACY: 27.6 Lm/W
Mounting
UPLIGHT
9.3%
Height
Multiplier
DOWNLIGHT
90.7%
-----------------------10
15
20
25
30
35
40
45
50
4.000
1.778
1.000
0.640
0.444
0.327
0.250
0.198
0.160
+ = Point of max candela
14' MOUNTING
Mounting
Height =HEIGHT
20 Feet. Each box represents one mounting height.
IES files can be found at www.aal.net
Reported data calculated from manufacturer's data file, based on IESNA recommended methods.
Photometric Viewer v3.4