2007 Commercial Products Catalog Distributed by: For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Australia: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 Toll Free: 866-764-5454 (315) 477-5531 FAX ORDERS ONLY: 1-866-653-0640 FAX: (315) 477-5179 crouse.customerctr@crouse-hinds.com Cooper Electrical Australia 61-29-743-7000 FAX: 61-29-743-7069 sales@cooperelectrical.com.au In Canada: Cooper Crouse-Hinds Canada Toll Free: 800-265-0502 (905) 507-4187 FAX ORDERS ONLY: 1-866-653-0645 FAX: (905) 568-7048 In Asia (Singapore): Cooper Crouse-Hinds Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819 sales@cchspore.com.sg In Middle East (Dubai): CEAG Middle East LLC 971-4-324-1519 FAX: 971-4-324-1640 In Mexico: In India: Cooper Crouse-Hinds, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4020 Cooper Crouse-Hinds India 91-22-5604-5150 FAX: 91-22-2404-1811 In Latin America/Caribbean: For the latest in new products and services, visit our website at: Cooper Crouse-Hinds (954) 764-3853 FAX: (954) 764-3854 www.crouse-hinds.com In Europe (Germany): Cooper Crouse-Hinds GmbH 49-6271-806500 FAX: 49-6271-806476 4733-0107 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2007 Cooper Industries, Inc. back cover Printed in U.S.A. spine front cover Commercial Products Table of Contents STEEL OUTLET BOXES NONMETALLIC CEILING BOXES • 4" and 411/ 16" square, switch, masonry, utility, outlet, ceiling fan and gangable boxes • Only full line of 4" square drawn and welded boxes • All welded 4" square boxes offer raised ground screw base for easier installation and labor savings – eliminates ground screw/surface interference • Drawn boxes available with concentric knockouts, combining 1/ 2" and 3/ 4" knockout in one location; 1/ 2" may be thumb-pushed out, requiring no tools • For use with wood or metal studs, cable or conduit • Complete line of covers, partitions, extension rings and accessories See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 • Made from heavy-duty engineered thermoplastic material or steel • Nonmetallic boxes offer quick entry and integral clamp features for a significant labor savings benefit • Ceiling boxes are available as fixture and ceiling fan rated • Available in a number of mounting methods See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PVC SWITCH BOXES AND COVERS • • • • Single and multigang For use with wood or metal studs Fire rated Device covers and low-voltage partitions STEEL STUD BRACKETED BOXES See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 • Special spring steel allows for quick and easy tool-free installation • Mounts on either side of stud and can be easily removed or repositioned • Sleek, low profile mounting bracket • Far side support bracket provides support for boxes in 21/ 4" – 4" studs • Far side support snaps easily onto box and is secured in place by plaster ring • Available in shallow and deep boxes for use with conduit, armored/metal cable or nonmetallic sheathed cable SPEED-MOUNT™ NONMETALLIC SWITCHBOXES See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 • Single and multigang • For use with wood or metal studs • Quick entry feature on all nonmetallic boxes offers labor savings • Integral labor saving clamping feature on two, three, and four gang boxes • Offer simple, labor saving press installation of devices • Far side support available designed for use with speed-mount boxes See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 UNI-MOUNT™ COVERS • Cover for 4" square boxes for mounting to metal and wood studs • Combines mounting bracket and device plate WEATHERPROOF PRODUCTS • Available in 1/ 2", 5/ 8" and 3/ 4" raised, as a single- or two-device cover • Universal design fits all 4" square boxes • Eliminates the need for far side support • Can be ordered preassembled to popular 4" square boxes for even greater labor savings • • • • Single, multigang and round outlet boxes Covers, adapters and extensions Vaporproof fixtures Lampholders, photo-controls, and accessories See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 FIXTURE HANGERS See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 • Ideal for commercial or light industrial applications where HID high bay and low bay lighting fixtures are used • Available in two styles; one for attachment to round and octagonal boxes, the other for attachment to 4" square boxes See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 1 Commercial Products Table of Contents WEATHERPROOF HID LUMINAIRES • Suitable for general lighting indoors and out • Available in Wall Packs, Floodlights and Area Lighting • Typical applications include parking garages, street lighting, recreational lighting, storage areas, stairwells, corridors, lobbies and security lighting FITTINGS (FOR USE WITH THINWALL & RIGID CONDUIT) See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 MYERS® HUBS The most complete offering of the preeminent name in hubs • Available as Scru-tite® hub in zinc or aluminum, 1/ 2" – 6", with or without grounding screw on the lock nut • Stainless steel hubs made from 316 stainless with stainless steel grounding screw, available from 1/ 2" – 2" • Through bulk-head hubs without nipples, available in zinc or aluminum from 1/ 2" – 2"; fittings supplied with nipples from 1/ 2" – 6" • IEC/CENELEC-approved hubs including increased safety ground terminal and locking screw on lock nut – ideal for OEMs with international applications • Metric-to-NPT adapters available in zinc or stainless • Cap-offs for knockouts available in zinc 1/ 2" – 2" or aluminum 1/ 2" – 2"; drain plugs available in 1/ 2" in aluminum and stainless steel • Optional nickel-chrome finish available for use with zinc Scru-tite hubs 1/ 2" – 21/ 2" • Extensive line of steel setscrew and compression connectors (insulated and noninsulated) and couplings from 1/ 2" – 4" for use with thinwall (EMT) conduit • Die-cast zinc setscrew and compression connectors (insulated and noninsulated) and couplings from 1/ 2" – 4" for use with thinwall (EMT) conduit • Extensive line of steel setscrew and compression connectors (insulated and noninsulated) and couplings from 1/ 2" – 6" for use with IMC and rigid conduit • Malleable three-piece couplings available from 1/ 2" – 6" • Rainboot, the only raintight threadless fitting, available from 1/ 2" – 2" • Malleable split conduit couplings available from 1/ 2" – 6" • Bushed nipples, pull elbows and offset conduit nipples available in malleable iron and die-cast zinc See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 EMT BENDSAVER™ CONDUIT STRAPS AND COUPLINGS • No offset bends required when installing conduit • Only one strap and one coupling are required per conduit run • Patented design eliminates conduit bending and allows for automatic alignment of EMT to box knockouts • Conduit straps are steel with zinc plating, couplings are zinc die cast See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81 RAINTIGHT MALLEABLE IRON CONDUIT HUBS • Male thread type • Tapered female thread for rigid conduit and IMC • Recessed o-ring gasket assures raintight and dust tight connections • Insulated throat provides smooth pulling surface • Locking screw on the nut doubles as a grounding screw for added safety • Complete size range from 1/ 2" to 6" • Hubs fit standard knockouts. No special tools required See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115 RAINTIGHT EMT COMPRESSION FITTINGS • All steel construction with zinc electroplate finish provides for durable corrosion resistance • Flat surface on gland nut provides smooth flat surface for easy wrenching • Integral ‘‘tri-level’’ sealing design includes steel compression ring, metal washer and nylon gasket for secure, reliable installation • Interior shoulder conduit stop provides positive seating of conduit inside the body • Gasket on male threads of box connector seals installation for raintight connection between the box and the connector • No disassembly required • Available in insulated and non-insulated versions, trade sizes 1/ 2" – 4" See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 2 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Commercial Products Table of Contents SPACE-SAVER EMT SETSCREW & COMPRESSION CONNECTORS & COUPLINGS GROUNDING BUSHINGS • Male threads on locknut allow for more room inside the box • Smooth pulling surface won’t strip cable— no bushing or insulated throat required • Angled teeth on locknut bite into enclosure, preventing loosening from vibration • Knurled wrenching surface for easy tightening • Zinc electroplated for corrosion resistance • Concrete tight when taped See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 FORM 5™ MALLEABLE IRON CONDUIT OUTLET BODIES • Available from 1/ 2" – 4" in the most popular conduit body shapes (C, LB, LL, LR, T, TB and X) • Domed sheet steel covers with stainless steel cover screws provide additional internal capacity • Cast iron covers available in 1/ 2" – 4" • Neoprene gaskets have perforated centers that are easily removed, if required • Completely interchangeable with Appleton® Form 35® and OZ/Gedney® malleable iron bodies and covers • UL List NEMA 4 Rated integral asket covers • All configurations available as SnapPack™ See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 SERIES 5® DIE-CAST ALUMINUM CONDUIT BODIES, COVERS & GASKETS • Available for use with rigid or EMT conduit (with setscrew) • Bodies available from 1/ 2" – 4" in the most popular conduit body shapes (C, LB, LL, LR, and T) • Available with fiber or neoprene gasket and aluminum cover as separate SKUs or prepackaged together and individually bar-coded as "SnapPack™" See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 • Available in 1/ 2" – 6" in threaded or setscrew style • Available with aluminum or copper lug which can be rotated 360°; open design for easy lay-in of wiring • Available in commercial-grade version rated for 105°C and hightemperature version rated for 150°C See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102 LIQUIDTIGHT FITTINGS Extensive product offering of Liquidtight fittings including: • Liquidator™ series available in malleable iron, aluminum, insulated or noninsulated, with or without grounding lug (copper or aluminum), and in straight, 45° or 90° configurations • LiQuik™ series, no disassembly required available in straight 3/ 8" – 2" trade sizes, insulated or non-insulated • Low Profile series available for confined space applications, in straight, 45° or 90° configurations, 3/ 8" – 2" trade sizes • Zinc Die Cast series available in straight or 90° configurations, 3/ 8" – 4" trade sizes, insulated or non-insulated • Nonmetallic Liquidtight fittings for use with Type B liquidtight conduit available in straight or 90° configurations, 1/ 2" – 1" trade sizes See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 CORD GRIPS IN METALLIC AND NONMETALLIC • Use with portable cords including S, SO, STO, ST, SJT, SJTO and SVO • Neoprene bushing • Metallic cord grips available in straight in 1/ 2" – 11/ 2" and 45° and 90°in 1/ 2" – 1" trade sizes • Nonmetallic cord grips available in straight 3/ 8"– 1" trade sizes See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136 ACB SERIES CONNECTORS (Armored Cable, Metal Clad and Flexible Metallic Conduit fittings) • Dual gripping saddle design on connector safely secures cable or conduit in place and prevents loosening from vibration • Insulated throat provides a smooth pulling surface that won’t strip cable • Angled teeth on locknut bit into enclosure, preventing loosening from vibrations • Available in straight 3/ 8" – 4", 45° 3/ 8" – 3/ 4" and 90° 3/ 8" – 1" See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 3 Commercial Products Table of Contents ACC SERIES COUPLINGS (Armored Cable, Metal Clad and Flexible Metallic Conduit fittings) CONDUIT CLAMPS & STRAPS • Dual gripping saddle design on the coupling safely secures cable or conduit in place and prevents loosening from vibration • Steel compression ring & nut provide a strong, secure termination point for EMT conduit • Available in both compression and set-screw (ACCSS) versions 3/ 8" – 3/ 4" • Wide variety of conduit clamps and straps for EMT, IMC and rigid conduit • Clamps include: right angle, parallel, edge, U-bolt and J series conduit beam clamps • Straps include: two hole, snap on, nailing, and malleable, plus cable and conduit hangers See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 SSACB SERIES CONNECTORS ACCESSORIES (Armored Cable, Metal Clad and Flexible Metallic Conduit fittings) • Extensive offering including: locknuts, plugs, pennies, reducing washers and conduit reducers • Male threads on locknut allow for more room inside the box • Smooth pulling surface eliminates the need for insulated throat fittings and/or conduit bushings • Dual gripping saddle design on the fitting safely secures cable or conduit in place and prevents loosening from vibration • Available 3/ 8" – 1" trade sizes See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 QUICK-LOK™ SQUEEZEAND-CLAMP TYPE CONNECTORS See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 W-SERIES CAST-IRON WEATHERPROOF JUNCTION BOXES & ACCESSORIES • Extensive line of over 196 boxes in five different styles (WAB, WCB, WJB, WJBF and WEB) • Many of the most popular sizes are available to ship within 24 hours when you request Lightning Service™ delivery • XJG internally grounded and XD weathertight expansion and deflection fittings available • One-piece steel construction for easy snap-in installation of MC and AC cable. Also suitable for use with 3/ 8" and 1/ 2" FMC connectors. Available in 1/ 2" and 3/ 4" sizes See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158 ZINC DIE CAST FITTINGS • Expanded line of connectors and couplings for EMT, AC & FMC conduit • Zinc EMT fittings available in set-screw and compression type fittings • Zinc AC & FMC fittings available in squeeze type, clamp type and screw-in type, straight or 90 degree angle • Available with insulators • Zinc material is naturally corrosion resistant See pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92-145 4 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds ALPHABETICAL INDEX PRODUCT CATALOG PAGE NUMBERS Adapters Knockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Angle Connectors Armored Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145 Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 Flexible Metallic Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145 Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126 Thinwall (EMT) Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 149 Anti-Short Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141, 147 Armored Cable Fittings ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 ACC Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 ACCSS Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Armored Cable Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 Quik-Lok . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 Space-Saver ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 BX Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Beam Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109, 141 Benders (EMT) Benders (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100 EMT Bendsaver™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 Bushings Anti-Short . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 147 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Insulated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104 Non-insulated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Pennies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104 Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 Cable Selection Chart153 Clampbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95, 109 Clamps AC/FMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109, 141 Edge Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Parallel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111, 141 Right Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111, 141 Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 141 Thinwall (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 149 Closure Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62, 75 Conduit Outlet Bodies Bodies, Covers & Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 Cast Iron Form 5™ Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109 Form 5™ Integral Gasket Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Form 5™ Malleable Iron Bodies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83, 106 Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 Connectors Armored Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 BX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Cord Metallic & Non-Metallic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136 Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149 EMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99 EMT Raintight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 EMT Space-Saver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 EMT Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100 Flexible Metal Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Greenfield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 Nonmetallic Sheathed Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149 Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100, 108 RAINBOOT™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83, 91, 141 Romex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Service Entrance Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Thinwall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99, 109, 149 Cord Grips Metallic & Non-Metallic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Couplings Combination: EMT–Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100, 109, 139 EMT–Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 99 US: 1-866-764-5454 CAN: 1-800-265-0502 PRODUCT CATALOG PAGE NUMBERS Liquidtight–Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126, 131 Rigid–Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100 Compression: EMT Raintight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 EMT Space-Saver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 EMT Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100 EMT(Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99 Expansion/Deflection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167 RAINBOOT™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 Rigid/IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 97 Duplex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149 Elbows Entrance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Pull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Entrance Caps EMT (Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Entrance Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Far Side Support for Speed-Mount boxes . . . . . . . . . . . . . . . . . . . . . . . . . .56 Flexible Metallic Conduit Fittings ACCSS Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 Greenfield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145, 149 Quik-Lok . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 Flexible Metallic Conduit Fittings ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 ACC Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Flexible Metallic Conduit Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Space-Saver ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 141, 145 Floodlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 Form 5™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120 Gaskets Conduit Body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 Sealing Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126 Grounding Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Liquidtight Conduit Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125, 133 Locknuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Hangers, Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111, 141 Hangers, Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74, 88 Heads Entrance, EMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Entrance, Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Hubs Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81 Iron Space Saver Conduit Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . .83, 87, 114 Raintight Malleable Iron Conduit Hubs . . . . . . . . . . . . . . . . . . . . . .83, 87, 114 Insert Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 Insulated Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Insulator Supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111, 141 Junction Boxes Cast, Weatherproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 Drill and Tapping Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164 Knockout, Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 Knockout, Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Lampholder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57, 66 Lazy-Lug® For Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128 Grounding Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102 Liquidtight Conduit Connectors LiQuik™ Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 Liquidator Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 Liquidtight Conduit Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125, 133 Low Profile Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 Non-metallic Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135 Zinc Die Cast Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127 Liquidtight Replacement Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . .131, 133 Locknuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Locknuts, Sealing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 Copyright© 2007 Cooper Crouse-Hinds 5 ALPHABETICAL INDEX PRODUCT CATALOG PAGE NUMBERS Luminaires HID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74, 88 Incandescent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 76 Myers® Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Nailing Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95, 109, 149 Nipples Bushed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Threaded Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 No-Thread Fittings EMT (Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99 Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 99 Non-insulated Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Offset Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100, 108 Offset Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42, 50, 52 Pennies, Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 Perforated Strap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Plastic Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Plastic Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Plugs, Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 Pre-Fab 4" Square Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Pull Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Push Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 Quick Lok® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149 RAINBOOT™ Set Screw Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Raintight Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reducing Washers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 Romex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 Sealing Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Sealing Locknuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Series 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117 Service Entrance Cable Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Spacers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109, 149 Set Screw: EMT Space-Saver Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 EMT Space-Saver Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 EMT Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100 EMT(Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99 Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 99 Split Conduit Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114 Three Piece Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106 Two Piece (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100 Speed-Mount™ Nonmetallic Switchboxes . . . . . . . . . . . . . . . . . . . . . . . . 56 Strain Relief Cord Connectors Strain Relief Cord Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136 Wire Mesh Grip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131 Straps EMT (Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 149 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Nailing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 149 Perforated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109 Switch & Outlet Boxes—Nonmetallic Covers: 4" Square & Round PVC Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Nonmetallic – Ceiling Boxes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 31/2" Diameter 4" Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 57 PVC – Switch Boxes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4" Square . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Multi-Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Multi-Gang Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Single Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Switch & Outlet Boxes—Steel Bar Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 Box & Bar Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 57 6 US: 1-866-764-5454 CAN: 1-800-265-0502 PRODUCT CATALOG PAGE NUMBERS Bracket & Clamp Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Ceiling Fan Boxes & Supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 57 Ceiling Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Concrete Boxes & Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Covers: 3-1/4" Round Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 4" Octagon Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 4" Square Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 4" Square Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 411/16" Square Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 Gang Box Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 Gang Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Masonry Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Plenum Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27, 40, 45 Uni-Mount™ Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Utility Box Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Hung Ceiling Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Outlet Boxes: 31/4" Octagon & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 4" Octagon & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 4" Square & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 411/16" Square & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Gang Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Masonry Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Plenum Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23, 30, 42 Pre-Fab 4" Square Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Steel Specialty Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Steel Stud Bracketed Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Utility Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Switch Boxes: 1" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 11/2" Deep 2" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 1 2 /2" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 21/4" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 23/4" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 31/2" Deep EC–extra capacity boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Instant–on boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Switch Box Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Utility Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 Switch Box Accessories Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Grounding Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Hold It Switch Box Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Stud Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Swiv-L-Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74, 88 U-Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 Uni-Mount™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 Unions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106 Wall Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 Watertight Connectors Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136 Weatherproof Covers: 1 & 2 Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 1 & 2 Gang GFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 1 & 2 Gang Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Aluminum Blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Extension Adaptor Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62 Round & Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Indoor/Outdoor Decorative: Lampholders & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 Wall Bracket Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72 Outlet Boxes: 1 & 2 Gang extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 2 & 3 Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Photoelectric Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 Round . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Single Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 Vapor Proof Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 76 Vapor Proof Fixtures & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 76 Wire Mesh Grips (Liquidtight) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Copyright© 2007 Cooper Crouse-Hinds O U T L E T B O X E S OUTLET BOXES MYERS® HUBS Outlet Boxes EMT FITTINGS RIGID / IMC FITTINGS GROUND BUSHINGS OUTLET BODIES LIQUIDTIGHT FITTINGS CORD AND CABLE CONNECTORS ARMORED CABLE AND FMC FITTINGS W-SERIES JUNCTION BOXES US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 7 Technical Data – Switch & Outlet Boxes Article 314 of the National Electrical Code® (NEC®) covers the installation and use of boxes. The article includes table references that guide the electrician in the selection of the proper size box necessary to safely accommodate electrical service requirements. The box capacity table is reproduced in part from NEC as a quick reference and guide. The NEC should be consulted for complete details. Cooper Crouse-Hinds products are produced in accordance with the requirements of UL-514-A, UL-514-B, UL514-C and are classified for fire resistance according to the standard, Fire Tests of Building Construction and Materials, ANSI/UL 263, ASTM E 119 and NFPA 251. This listing is based on products when used in a fire rated (2 HR) wall or ceiling. Cooper Crouse-Hinds steel boxes are listed with U.L. File #E23156 and Cooper CrouseHinds nonmetallic boxes are listed with U.L. File #E102328 and U.L. (2 HR. fire rated) File #R9933. Cooper Crouse-Hinds switch and outlet boxes comply with the requirements of NEMA standard OS-1, NFPA 70-370 and Federal Spec. #W-J-800E. Under File #E23156, Cooper Crouse-Hinds concentric and "Moon" KO style boxes, the following is stated "Suitable for bonding without any additional bonding means around concentric (or Eccentric) knockouts where used in circuits above or below 250V." Cooper Crouse-Hinds NAED/DCI/UPC number is 786189-10 plus the 3-digit product number. On the outlet box 4-digit product number, the NAED/DCI/UPC number is 786189-0 plus the 4-digit product number and for the 5-digit product number, the NAED/DCI/UPC number is 786189 plus the 5-digit number. Table 314.16 (A) Metal Boxes Min. Maximum Number of Conductors Cu. In. Cap. No. 18 No. 16 No. 14 No. 12 No. 10 No. 8 No. 6 Box Dimension, Inches Trade Size or Type 4 × 11/ 4 Round or Octagonal 4 × 11/ 2 Round or Octagonal 4 × 21/ 8 Round or Octagonal 4 × 11/ 4 Square 4 × 11/ 2 Square 4 × 21/ 8 Square 411/ 16 × 11/ 4 Square 411/ 16 × 21/ 2 Square 411/ 16 × 21/ 8 Square 3 × 2 × 11/ 2 Device 3 × 2 × 2 Device 3 × 2 × 21/ 4 Device 3 × 2 × 21/ 2 Device 3 × 2 × 23/ 4 Device 3 × 2 × 31/ 2 Device 4 × 21/ 8 × 11/ 2 Device 4 × 21/ 8 × 17/ 8 Device 4 × 21/ 8 × 21/ 8 Device 33/ 4 × 2 × 21/ 2 Masonry Box/Gang 33/ 4 × 2 × 31/ 2 Masonry Box/Gang FS-Minimum Internal Depth 13/ 4 Single Cover Gang FD-Minimum Internal Depth 23/ 8 Single Cover Gang FS-Minimum Internal Depth 13/ 4 Single Cover Gang FD-Minimum Internal Depth 23/ 8 Multiple Cover Gang 12.5 15.5 21.5 18.0 21.0 30.3 25.5 29.5 42.0 7.5 10.0 10.5 12.5 14.0 18.0 10.3 13.0 14.5 14.0 21.0 8 10 14 12 14 20 17 19 28 5 6 7 8 9 12 6 8 9 9 14 7 8 12 10 12 17 14 16 24 4 5 6 7 8 10 5 7 8 8 12 6 7 10 9 10 15 12 14 21 3 5 5 6 7 9 5 6 7 7 10 5 6 9 8 9 13 11 13 18 3 4 4 5 6 8 4 5 6 6 9 5 6 8 7 8 12 10 11 16 3 4 4 5 5 7 4 5 5 5 8 4 5 7 6 7 10 8 9 14 2 3 3 4 4 6 3 4 4 4 7 2 3 4 3 4 6 5 5 8 1 2 2 2 2 3 2 2 2 2 4 13.5 9 7 6 6 5 4 2 18.0 12 10 9 8 7 6 3 18.0 12 10 9 8 7 6 3 24.0 16 13 12 10 9 8 4 Table 314.16 (B) Volume Required per Conductor Size of Conductor Free Space Within Box for Each Conductor No. 18 No. 16 No. 14 No. 12 No. 10 No. 8 No. 6 1.5 cubic inches 1.75 cubic inches 2 cubic inches 2.25 cubic inches 2.5 cubic inches 3 cubic inches 5 cubic inches For SI units: one cubic inch = 16.4 cm3. Reprinted with permission from NFPA 70-2005, the National Electrical Code®, Copyright® 2005 National Fire Protection Association, Quincy MA 02269. This reprinted material is not the complete and official position of the National Fire Protection Asociation, on the referenced subject which is represented only by the standard in its entirety. National Electrical Code® and NEC® are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA 02269. Wall thickness on all Steel boxes is 0.0625" 8 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Technical Data – Switch & Outlet Boxes COOPER CROUSE-HINDS SWITCH BOX DETAILS 1/ 2" Conduit KO 3/ 4" Conduit KO 1" Conduit KO Concentric 1/2" and 3/4" KO Eccentric 1/2" and 3/4" KO Cable Pry-outs always in pairs. Knockouts and Pry-outs Cooper Crouse-Hinds conduit KOs have standard trade size dimensions. KOs are uniform and true for attachment of cable or conduit connectors. Pry-outs for cable entrance are slotted – a twist with screwdriver removes them. KOs and Pryouts are precision stamped to permit easy removal, but remain sufficiently strong and sturdy when not removed. Cooper Crouse-Hinds 4" sq. drawn boxes feature a 1/ 2" and 3/ 4" "inverted" concentric KO – easily removed. Our 4" sq. welded feature our 1/ 2" eccentric KO which also features easy removability of both the 1/ 2" and 3/ 4" KOs. Notes: These KOs are suitable for bonding without bonding jumpers around concentric (or eccentric) knockouts where used in circuits above or below 250V. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 9 Mounting Information Steel Boxes BRACKETS USED ON COOPER CROUSE–HINDS BOXES "F" BRACKET "D" BRACKET "S" BRACKET "C" BRACKET Mounts on face of stud. See catalog number for set back. For wood studs. Side mount bracket with set up hook & guide tabs for automatic positioning. Standard bracket set back is 5/ 8". For wood and metal studs. Side mount brackets with set up hook for wood or metal studs. Standard bracket set back is 5/ 8". Ceiling box bracket for wood studs. "VS" BRACKET "VMS" BRACKET "VP" BRACKET "SSB" BRACKET Plain flat mounted bracket for use on wood or metal studs. No set back. Side bracket for use with wood or metal studs. Provides set up tabs to position on face of stud. Side bracket with set up hooks for wood studs. Positions box on either side of a steel stud. CLAMPS USED ON COOPER CROUSE-HINDS BOXES Cat. # TP900 MC-BX FOR ARMORED & METAL CLAD (MCI) CABLE NM-1 NM-2 FOR NONMETALLIC CABLE NM-4 MOUNTING EARS Cat. # TP901 Cat. # TP902 ONE SCREW EAR TWO SCREW EAR Mounting ears are available on many of our switch boxes. They are set forward in and one-screw ears on deep boxes. 10 US: 1-866-764-5454 1/ 16" CAN: 1-800-265-0502 the "old way" position. Two-screw ears are generally used on shallow boxes Copyright© 2007 Cooper Crouse-Hinds Steel Switch Boxes 1" DEEP SWITCH BOXES – NON-GANGABLE – 6.5 CUBIC INCH CAPACITY 115/16" WIDE × 33/4" LONG Steel Boxes TP101 TP103 Cat. # Bracket Plastic Clamp TP101 TP103 "S" "S" No Yes KNOCKOUTS Conduit Cable 1 – 1/ 2" 1 – 1/ 2" 2 2 Std. Unit Pkg. Wt. Lbs. Per 100 25 25 38 39 11/2" DEEP SWITCH BOXES – NON-GANGABLE – 7.5 CUBIC INCH CAPACITY 2" WIDE × 3" LONG TP100 Cat. # Bracket TP104 Ears TP106 KNOCKOUTS Each Side Each End TP114 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 50 50 43 50 FOR ARMOURED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP106 — Yes 2 – Cable — 1 – 1/ 2" 50 44 FOR CONDUIT – NO CLAMPS, FLUSH DEVICE TP114 — Yes 1 – 1/ 2" 1 – 1/ 2" 50 39 FOR NONMETALLIC CABLE – CLAMPS IN EACH END TP100 — Yes 2 – Cable TP104 — 2 – Cable "S", set 1/ 2" US: 1-866-764-5454 — — — CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 11 Steel Switch Boxes 2" DEEP SWITCH BOXES – GANGABLE – 10.0 CUBIC INCH CAPACITY Steel Boxes 2" WIDE × 3" LONG, FOR NONMETALLIC CABLE – CLAMPS IN EACH END TP116 TP118 Cat. # Bracket Ears Each End TP116 TP118 — "S", Set 1/ 2" Yes — 2 – Cable 2 – Cable KNOCKOUTS Each Side — — Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 50 50 53 60 FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP120 Cat. # TP120 TP123 TP124 Bracket — "F", Set 1/ 2" "S", Set 1/ 2" TP123 Ears Yes — — Each End KNOCKOUTS Each Side 2 – Cable 2 – Cable 2 – Cable TP124 Bottom 1/ 2" — — — 1– 1 – 1/ 2" 1 – 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 54 63 61 FOR CONDUIT – NO CLAMPS, FLUSH DEVICE TP126 TP130 Cat. # Bracket Ears Each End TP126 TP130 TP132 TP131 — — "S", Set 1/ 2" Hold-Tite — Yes — Yes 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2"–T 12 US: 1-866-764-5454 TP132 KNOCKOUTS Each Side 2 – 1/ 2" 2 – 1/ 2" 2 – 1/ 2", 1 Side — CAN: 1-800-265-0502 Bottom 1 1 1 1 – – – – TP131 Hold-Tite Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 47 48 58 52 1/ 2" 1/ 2" 1/ 2" 1/ 2" Copyright© 2007 Cooper Crouse-Hinds Steel Switch Boxes 21/4" DEEP SWITCH BOXES – GANGABLE – BEVELED CORNERS 10.5 CUBIC INCH CAPACITY 2" WIDE × 3" LONG, CLAMP SCREWS THROUGH BEVELED CORNERS Steel Boxes TP134 Cat. # TP134 TP137 TP138 Ears — Yes Yes TP137 Hold-Tite Bumps Yes — — Each End 2 – Cable 2 – Cable 2 – Cable US: 1-866-764-5454 KNOCKOUTS Each Side — — — CAN: 1-800-265-0502 TP138 Bottom 1/ 2" 1– 1 – 1/ 2" 1 – 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 51 57 55 Copyright© 2007 Cooper Crouse-Hinds 13 Steel Switch Boxes 21/2" DEEP SWITCH BOXES – GANGABLE – 12.5 CUBIC INCH CAPACITY Steel Boxes 2" WIDE × 3" LONG FOR NONMETALLIC CABLE – CLAMPS IN EACH END TP158 TP162 TP163 TP170 TP161 TP172 TP164 TP168 TP174 TP171 KNOCKOUTS Cat. # TP115 TP158 TP161 TP162 TP163 TP164 TP168 TP170 TP172 TP174 TP171 14 Bracket — — Snap-In — Hold-Tite "F", Set 1/ 2" "F", Set 1/ 4" "S", Set 5/ 8" "D", Set 5/ 8" "D", Set 5/ 8" "VP", Set 1/ 2" Ears — Yes Yes Yes Yes — — — — — — Ground Pigtail — Yes — — — — — — — Yes — US: 1-866-764-5454 Leveling Bumps Yes — — — — — — — — — — Each End 2 – Cable, 1 – 2 – Cable 2 – Cable 2 – Cable 2 – Cable 2 – Cable, 1 – 2 – Cable, 1 – 2 – Cable, 1 – 2 – Cable, 1 – 2 – Cable, 1 – 2 – Cable, 1 – CAN: 1-800-265-0502 Each Side 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" — 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" — 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" Bottom 1/ 2" 1– 1 – 1/ 2" — 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" Copyright© 2007 Cooper Crouse-Hinds Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 50 50 50 50 50 50 50 59 63 73 62 65 71 71 69 70 71 73 Steel Switch Boxes 21/2" DEEP SWITCH BOXES – GANGABLE – 12.5 CUBIC INCH CAPACITY 2" WIDE × 3" LONG FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP178 TP179 Hold-Tite TP184 TP185 KNOCKOUTS Each Side Cat. # Bracket Ears Each End TP177 TP178 TP179 TP180 TP184 TP185 Snap-In — Hold-Tite "F", Set 1/ 2" "S", Set 5/ 8" "VP", Set 1/ 2" Yes Yes Yes — — — 2 – Cable 2 – Cable 2 – Cable 2 – Cable, 1 – 1/ 2" 2 – Cable, 1 – 1/ 2" 2 – Cable, 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" — 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" Bottom 1 1 1 1 1 Steel Boxes TP177 TP180 Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 50 50 74 63 66 72 70 74 — – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" GANG SWITCH BOXES WITH VP BRACKET, SET BACK 1/2" 21/2" DEEP – 33/4" HIGH – 1/2" AND 3/4" CONCENTRIC KOs TP632 TP633 Cat. # Gang Width Each End TP632 TP633 3 4 59/ 16" 73/ 8" 2 2 KNOCKOUTS Each Side US: 1-866-764-5454 3 4 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. 6 8 5 5 143 179 46.5 62.0 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 15 Steel Switch Boxes 21/2" DEEP "EC" BOXES – GANGABLE – CUBIC INCH CAPACITY (SEE BELOW) Steel Boxes 2" WIDE × 3" LONG CLAMPS IN EACH END TP188 TP190 TP196 NOW… The Cubic Capacity of any of our new work 21/ 2" Deep Switch Boxes can be increased to 18 cubic inches simply by adding our "EC" Extender to the sides of the box. This provides 5.5 extra cubic inches of space necessary to conform to revisions in the National Electrical Code. "EC" boxes are stocked factory assembled in popular styles, however the "EC" Extender can be ordered separately for "Instant-On" assembly on the job with Cooper Crouse-Hinds Switch Boxes. Cat. # Bracket Each End TP188 — — KNOCKOUTS Each Side FOR NONMETALLIC CABLE TP190 "D", Set 5/ 8" 2 – Cable, 1 – 1/ 2" TP196 "S", Set 5/ 8" 2 – Cable, 1 – 1/ 2" Bottom Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. — — 50 32 5.5 — — 1 – 1/ 2" 1 – 1/ 2" 25 25 89 89 18.0 18.0 21/2" DEEP SWITCH BOXES – GANGABLE – 12.5 CUBIC INCH CAPACITY 2" WIDE × 3" LONG FOR CONDUIT – NO CLAMPS Cat. # TP214 TP216 TP217 TP218 TP220 TP222 TP224 16 TP214 TP216 TP217 TP220 TP222 TP224 Bracket — Snap-In — — "F", Set 1/ 2" "S", Set 5/ 8" Hold-Tite Ears — Yes Yes Yes — — Yes Leveling Bumps Yes — — — — — — US: 1-866-764-5454 Each End 1 1 1 1 1 1 1 – – – – – – – 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" CAN: 1-800-265-0502 KNOCKOUTS Each Side — 1 – 1/ 2" — 1 – 1/ 2" 1 – 1/ 2", 1 Side 1 – 1/ 2", 1 Side — TP218 Bottom 1/ 2" 1– — 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" Copyright© 2007 Cooper Crouse-Hinds Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 50 50 50 55 69 64 58 66 65 61 Steel Switch Boxes 21/2" DEEP SWITCH BOXES – "INSTANT ON" – 12.5 CUBIC INCH CAPACITY 2" WIDE × 3" LONG WITH BUMPS – CLAMPS IN EACH END (BUMPS LEVEL THE BOX AGAINST THE SIDE OF STUD, TOP TO BOTTOM, FRONT TO BACK) Steel Boxes TP206 TP210 Cat. # Clamps Nails TP206 TP210 TP213 Nonmetallic Nonmetallic Armored Cable — Angle Angle TP213 KNOCKOUTS Each End Each Side 2 – Cable, 1 – 1/ 2" 2 – Cable, 1 – 1/ 2" 2 – Cable, 1 – 1/ 2" — — — Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 50 50 50 61 66 66 23/4" DEEP SWITCH BOXES – GANGABLE – 14.0 CUBIC INCH CAPACITY 2" WIDE × 3" LONG FOR NONMETALLIC CABLE – CLAMPS IN EACH END TP660 TP662 Cat. # Bracket Ears Each End TP660 TP662 TP664 — — "S", Set 5/ 8" — Yes — 2 – Cable 2 – Cable 2 – Cable KNOCKOUTS Each Side 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" TP664 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 50 50 50 62 67 70 FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP668 Cat. # TP668 TP670 Bracket — "S", Set 5/ 8" TP670 Ears Yes — Each End 2 – Cable 2 – Cable US: 1-866-764-5454 KNOCKOUTS Each Side 1/ 2" 1– 1 – 1/ 2" CAN: 1-800-265-0502 Bottom 1/ 2" 1– 1 – 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 50 50 68 71 Copyright© 2007 Cooper Crouse-Hinds 17 Steel Switch Boxes 23/4" DEEP SWITCH BOXES – GANGABLE – 14.0 CUBIC INCH CAPACITY Steel Boxes 2" WIDE × 3" LONG FOR CONDUIT – NO CLAMPS TP672 TP674 (TP676 – 1 screw ear) (TP678 – 2 screw ear) Cat. # Bracket Ears TP672 TP674 TP676 TP678 TP680 TP677 — — — — "S", Set 5/ 8" "S", Set 5/ 8" — — Yes Yes — — Each End 1 1 1 1 1 1 – – – – – – KNOCKOUTS Each Side 1/ 2" 1 – 1/ 2" 1 – 3/ 4" 1 – 1/ 2" 1 – 3/ 4" 1 – 1/ 2", 1 Side 1 – 3/ 4", 1 Side 3/ 4" 1/ 2" 3/ 4" 1/ 2" 3/ 4" TP680 TP677 Bottom 1 1 1 1 1 1 – – – – – – Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 50 50 59 59 61 61 70 70 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 21/2" DEEP SWITCH BOX – GANGABLE – 16.0 CUBIC INCH CAPACITY 2" WIDE × 33/4" LONG FOR NONMETALLIC CABLE – CLAMPS IN EACH END TP226 Cat. # Clamps Bracket Each End TP226 Nonmetallic External Nail 1 – 1/ 2" 18 US: 1-866-764-5454 KNOCKOUTS Each Side 2 – 1/ 2" CAN: 1-800-265-0502 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 50 35 Copyright© 2007 Cooper Crouse-Hinds Steel Switch Boxes 31/2" DEEP SWITCH BOXES – GANGABLE – 18.0 CUBIC INCH CAPACITY 2" WIDE × 3" LONG FOR NONMETALLIC CABLE – CLAMPS IN EACH END Steel Boxes TP236 TP238 TP239 TP242 TP243 Cat. # Bracket Ground Pigtail Ears TP236 TP238 TP239 TP240 TP242 TP243 — — — "F", Set 1/ 2" "S", Set 7/ 8" "S", Set 7/ 8" — — Yes — — Yes — Yes Yes — — — US: 1-866-764-5454 Each End 2 2 2 2 2 2 – – – – – – Cable, Cable, Cable, Cable, Cable, Cable, 1 1 1 1 1 1 – – – – – – CAN: 1-800-265-0502 KNOCKOUTS Each Side 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 2 2 2 2 2 2 – – – – – – 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" TP240 Bottom 1 1 1 1 1 1 – – – – – – 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" Copyright© 2007 Cooper Crouse-Hinds Std. Unit Pkg. Wt. Lbs. Per 100 25 25 25 25 25 25 78 80 81 88 87 88 19 Steel Switch Boxes 31/2" DEEP SWITCH BOXES – GANGABLE – 18.0 CUBIC INCH CAPACITY Steel Boxes 2" WIDE × 3" LONG FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP244 TP249 TP246 KNOCKOUTS Each Side Cat. # Bracket Ground Pigtail Ears Each End TP244 TP249 TP246 — — "S", Set 7/ 8" — Yes — Yes Yes — 2 – Cable, 1 – 1/ 2" 2 – Cable, 1 – 1/ 2" 2 – Cable, 1 – 1/ 2" 2 – 1/ 2" 2 – 1/ 2" 2 – 1/ 2" Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 25 25 25 81 82 88 FOR CONDUIT – NO CLAMPS TP248 TP250 TP252 Cat. # Bracket Ears TP248 TP250 TP252 TP254 — — — — — — Yes Yes 20 Each End 2 2 2 2 1/ 2" – – 3/ 4" – 1/ 2" – 3/ 4" US: 1-866-764-5454 KNOCKOUTS Each Side 2 2 2 2 1/ 2" – – 3/ 4" – 1/ 2" – 3/ 4" CAN: 1-800-265-0502 TP254 Bottom 1 1 1 1 1/ 2" – – 1/ 2" – 1/ 2" – 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 25 25 25 25 74 74 76 76 Copyright© 2007 Cooper Crouse-Hinds Switch Box Accessories GROUNDING DEVICES GROUNDING SCREW AND PIGTAIL TP700 or TP702 TP703 or TP707 TP701 or TP705 Description TP700 TP701 TP702* TP703 TP705 TP707 TP704 Grounding Screw with 6" Bare No. 14 Copper Wire Grounding Screw with Insulated No. 12 Stranded Wire – 8" overall Grounding Screw with 6" Bare No. 12 Copper Wire Grounding Screw with 6" Insulated No. 12 Copper Wire Grounding Screw with Insulated No. 14 Stranded Wire – 8" overall Grounding Screw with 6" Insulated No. 14 Copper Wire #10-32 x 3/ 8" Grounding Screw Std. Pkg. Unit Pkg. Wt. Lbs. Per 100 1000 1000 1000 1000 1000 1000 1000 50 50 50 50 50 50 100 1 2 2 2 1 1 .5 Steel Boxes Cat. # TP704 *TP702 is standard wire installed in Cooper Crouse-Hinds boxes GROUNDING CLIP TP706 Cat. # Description TP706 For Grounding Switch & Outlet Boxes Using Nonmetallic Sheathed Cables No. 14 & No. 12, with Grounding Wire Std. Pkg. Unit Pkg. Wt. Lbs. Per 100 1000 100 .5 OLD WORK CLIP TP651 Cat. # Description Std. Pkg. Unit Pkg. Wt. Lbs. Per 100 TP651 Clips lock old-work steel switch boxes tightly to wall. Two required per box. 250 sets 25 sets 4 REPLACEMENT PARTS TP900 TP901 Cat. # Description TP900 TP901 TP902 MC-BX Clamp with Screws One Screw Mounting Ear with Screws Two Screw Mounting Ear with Screws US: 1-866-764-5454 CAN: 1-800-265-0502 TP902 Unit Pkg. Wt. Lbs. Per 100 200 200 200 17.3 3.2 2.7 Copyright© 2007 Cooper Crouse-Hinds 21 Switch Box Accessories Steel Boxes HOLD-IT SWITCH BOX SUPPORTS FIG. 1 FIG. 2 FIG. 3 Cat. # Description Std. Pkg. Carton Quantity Wt. Lbs. Per 100 TP708 Two metal holders for mounting old-work switch boxes in all types of wall materials 500 Sets 50 Sets 5 Std. Pkg. Capacity Cu. In. Wt. Lbs. Per 100 50 3.5 13 SWITCH BOX EXTENSION TP709 Cat. # Description TP709 Fits snugly inside all 3" x 2" width boxes. Maximum adjustable depth 7.8". Furnished with mounting screws. P-300 STEEL STUD SAFETY PLATE • • • • Meets requirement of National Electric Code Same size as face of stud No nails required Protects electrical cable and copper water pipes Cat. # Description TP659 2" x 31/ 2" Steel Plate 22 US: 1-866-764-5454 CAN: 1-800-265-0502 Std. Pkg. Wt. Lbs. Per 100 100 11 Copyright© 2007 Cooper Crouse-Hinds Steel Octagon Boxes & Ceiling Pans 31/4" OCTAGON OUTLET BOXES* – 11.5 CUBIC INCH CAPACITY 11/2" DEEP Cat. # TP258 TP259 Description FOR CONDUIT – NO CLAMPS TP256 — TP258 Extension Ring FOR NONMETALLIC CABLE WITH CLAMPS TP259 "S" Bracket, Set 1/ 2" TP260 — TP262 With Side Nail Holes TP264 Two Screw Ears 4 4 4 4 – – – – TP260 TP262 TP264 KNOCKOUTS Sides Bottom Std. Unit Pkg. Wt. Lbs. Per 100 4 – 1/ 2" 4 – 1/ 2" 1 – 1/ 2" — 50 50 41 31 1/ 2" 50 50 50 50 53 44 43 47 Cable, Cable, Cable, Cable, 1 2 2 2 – – – – 1/ 2" 1 1 1 1 1/ 2" 1/ 2" 1/ 2" – – – – 1/ 2" 1/ 2" 1/ 2" Steel Boxes TP256 31/4" ROUND CELING PAN* – 4.0 CUBIC INCH CAPACITY 1/ 2" DEEP CLAMPS IN BOTTOM TP266 TP270 Cat. # Cable TP266 4 KNOCKOUTS Conduit 1– TP272 Std. Unit Pkg. Wt. Lbs. Per 100 50 30 100 100 18 18 1/ 2" 31/4" ROUND COVERS TP270 TP272 Flat Blank Flat, 1/ 2" KO in Center 4" ROUND CELING PANS* – 6.0 CUBIC INCH CAPACITY 1/ 2" DEEP TP269 Cat. # Description TP269 TP267 KOs Only KOs and Clamps TP267 Sides — — KNOCKOUTS Bottom 5 – 1/ 2" 4 – Cable, 3 – 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 50 50 35 39 *Weight limit for 31/ 4" and 4" octagon outlet boxes and ceiling pans is 50lbs for fixture. Not suitable for fans. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 23 Steel Octagon Boxes 4" OCTAGON OUTLET BOXES† – 15.5 CUBIC INCH CAPACITY Steel Boxes 11/2" DEEP FOR CONDUIT – NO CLAMPS TP274, TP276, TP278, TP834* TP273 TP280 TP282 TP284, TP286 KNOCKOUTS Cat. # Description TP274 TP273 TP276 TP278 TP280 TP282 — Blank Bottom — — "C" Bracket "S" Bracket, Set 1/ 2" Air Plenum TP834* For Air Plenum Sides Bottom Std. Unit Pkg. Wt. Lbs. Per 100 4– 4 – 1/ 2" 4 – 3/ 4" 2 – 1/ 2", 2 – 3/ 4" 4 – 1/ 2" 3 – 1/ 2" 1/ 2" 5– — 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 5 – 1/ 2" 5 – 1/ 2" 50 50 50 50 50 50 50 51 50 50 60 58 4 – 1/ 2" 5 – 1/ 2" 50 52 1/ 2" OCTAGON EXTENSION RINGS – (SLOT & KEY PERMIT MOUNTING WITHOUT REMOVING BOX SCREWS) TP284‡ — — 50 4 – 1/ 2" — 50 TP286‡ — 2 – 1/ 2", 2 – 3/ 4" 36 36 *For Air Plenum (No Mounting Holes) † Weight limit for 31/ 4" and 4" octagon outlet boxes and ceiling pans is 50lbs for fixture. Not suitable for fans ‡ CSA Certified 11/2" DEEP FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP310 Cat. # Description TP310 TP312 TP314 — "C" Bracket "S" Bracket, Set 1/ 2" 24 TP312 KNOCKOUTS Sides 4 – Cable, 2 – 1/ 2" 4 – Cable, 2 – 1/ 2" 4 – Cable, 1 – 1/ 2" US: 1-866-764-5454 CAN: 1-800-265-0502 TP314 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 50 50 50 57 66 64 Copyright© 2007 Cooper Crouse-Hinds Steel Octagon Boxes 4" OCTAGON OUTLET BOXES – 15.5 CUBIC INCH CAPACITY 11/2" DEEP FOR NONMETALLIC CABLE – WITH CLAMPS Steel Boxes TP298 Cat. # TP298 TP300 TP302 TP304 TP306 TP308 TP300 TP302 KNOCKOUTS Sides Description — With Side Nail Holes "C" Bracket "S" Bracket, Set 1/ 2" Two Screw Ears "F" Bracket, Set 1/ 2" TP304 4 4 4 4 4 4 – – – – – – Cable, Cable, Cable, Cable, Cable, Cable, 2 2 2 1 2 1 – – – – – – Bottom 1/ 2" 1 1 1 1 1 1 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" – – – – – – TP306 TP308 Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 50 50 56 55 65 64 58 64 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 1/ 2" 4" OCTAGON OUTLET BOXES – 21.5 CUBIC INCH CAPACITY 21/8" DEEP FOR CONDUIT – NO CLAMPS TP288, TP290, TP294 TP292, TP838* TP339 KNOCKOUTS Cat. # Description Sides TP288 TP290 TP292 TP294 TP339 — — — — Blank Bottom 4 – 1/ 2" 4 – 3/ 4" 2 – 1/ 2", 2 – 3/ 4" 4 – 1" 4 – 1/ 2" 3 3 3 3 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 3/ 4" 25 25 25 25 25 64 64 64 64 65 Air Plenum TP838* Plenum 2 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 25 62 – – – – 1/ 2", 2 1/ 2", 2 1/ 2", 2 1/ 2", 2 — – – – – 3/ 4" 3/ 4" 3/ 4" *For Air Plenum (No Mounting Holes) US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 25 Steel Octagon Boxes 4" OCTAGON OUTLET BOXES – 21.5 CUBIC INCH CAPACITY Steel Boxes 21/8" DEEP – WITH CABLE CLAMPS TP316 Cat. # TP318 TP320 KNOCKOUTS Sides Description TP317 TP338 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 1 – 1/ 2" 25 25 25 68 88 81 FOR ARMORED & METAL CLAD (MCI) – CABLE-CLAMPS IN EACH END TP317 — 4 – Cable, 2 – 1/ 2" 1 – 1/ 2" TP338 4 – Cable, 1 – 1/ 2" 1 – 1/ 2" "S" Bracket, Set 1/ 2" 25 25 69 82 FOR NONMETALLIC CABLE TP316 — TP318 "C" Bracket TP320 "S" Bracket, Set 1/ 2" 26 4 – Cable, 2 – 1/ 2" 4 – Cable, 2 – 1/ 2" 4 – Cable, 1 – 1/ 2" US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Steel Octagon Covers & Accessories 4" OCTAGON BOX COVERS – CUBIC CAPACITY (SEE BELOW) TP323 TP326, TP331, TP332, TP333 TP328 TP329 TP335 TP334 TP336 TP330 Cat. # Description Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 TP322† TP323† TP333 TP332 TP326 TP331 TP328† TP330 TP329† TP335 TP334 TP336 Flat Blank – Octagon Shape Flat Blank – Round Shape Raised 1", Open With Ears 23/ 4" Raised 1/ 2", Open With Ears 23/ 4" Raised 5/ 8", Open With Ears 23/ 4" Raised 3/ 4", Open With Ears 23/ 4" Flat With 1/ 2" KO – Octagon Shape Raised 5/ 8", With 1/ 2" KO Flat With 1/ 2" KO – Round Shape Flat, For Toggle Switch Flat, Single Receptacle 113/ 32" Flat, For Duplex Receptacle — — 7.0 3.3 3.8 5.0 — 3.8 — — — — 50 50 25 50 50 50 50 50 50 50 50 50 22 24 30 22 20 26 22 31 24 23 21 18 Air Plenum TP853* Flat, Blank With PVC Gasket — 50 24 Steel Boxes TP322 TP853* *For Air Plenum (No Mounting Holes) †CSA Certified ADJUSTABLE BAR HANGERS HOLDING PRONG . . . HOLDS BOX IN PLACE FOR NAILING – DESIGN RESISTS BENDING AND TWISTING – TP354 AND TP356 HAVE LOCKING TABS TO HOLD BAR IN POSITION Weight Limits: 35 lbs. at 16", 15 lbs. at 24". TP356 TP354 Cat. # Stud Spacing Length Stud Std. Unit Pkg. Wt. Lbs. Per 100 TP354 TP356 16" & 24" 16" & 24" 14" – 221/ 2" 14" – 221/ 2" Yes — 50 50 43 41 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 27 Ceiling Fan Box And Supports Steel Boxes CEILING FAN BOXES – CUBIC INCH CAPACITY (SEE BELOW) Weight Limits: TP261 – 35 lbs. max. for fans, 50 lbs. max. for fixture. TP301 – Fan is supported independent of outlet box, mounting screws go through box and into joist. Box will support fans up to 70 lbs. and fixtures up to 90 lbs. TP275 – 70 lbs, max. for fans, 90 lbs. max for fixtures. TP275 Cat. # Description TP275 11/ 2" Deep, Clamps and Mounting Screws (polybagged) TP261 5/ 8" Deep with External Clamp and Mounting Screws (polybagged) 8.0 TP301* 1/ 2" Deep, 4" Round, with NM Snap-In Connector, mtg. screws, Protective Cover (no bag) 6.8 TP261 Cubic In. Capacity 15.5 KNOCKOUTS Sides Bottom TP301 WEIGHT LIMITS Fans Fixtures Std. Unit Pkg. Wt. Lbs. Per 100 4 – Cable, 2 – 1/ 2" 1 – 1/ 2" 20 66.6 70 lbs. 90 lbs. — 2 – 1/ 2" 20 50 35 lbs. 50 lbs. — 3 – 1/ 2" 20 51 70 lbs.* 90 lbs.* *TP301 fan is supported independent of outlet box CEILING FAN BOXES AND SUPPORTS Weight Limits: Up to 35 lbs. for fans. Up to 50 lbs. for fixtures. TP315 Cat. # Description Stud Spacing TP379 Capacity. Cu. In. KNOCKOUTS Bottom Side 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 1/ 2" 12 192 12 207 TP315† Fan Box with New Work Bar Hanger 16" – 24" 15.5 2– TP379 11/ 2" Deep with Fan Brace Old Work Bar Hanger 16" – 24" 15.5 2 – 1/ 2" 4 – 1/ 2" 2– †TP315 comes with Romex clamp installed on one side. The other 3 sides have a 1/ 2" KO, a bagged MC clamp and screw and a bagged plastic NM connector CEILING FAN BOXES – PVC Weight Limits: Fans and fixtures are supported independent of outlet box. Mounting screws go through box and into joist. Box will support up to 70 lbs. for fans and 90 lbs. for fixtures. Provided with Romex connector TP1300 Cat. # Description Capacity Cu. In. Knockouts Integral Clamp Std. Unit Pkg. Wt. Lbs. Per 100 TP1300 41/ 16" diam., 1/ 2" deep pan section, 4" deep overall – with mtg. hardware & external clamp, protective cover 14.0 3 – 1/ 2" 1 24 34 TP1300 1 Same as 1300, packed in counter display 14.0 3 – 1/ 2" 1 24 35 28 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Ceiling Fan Boxes & Steel Octagon Boxes NONMETALLIC CEILING FAN BOXES • • • • Made of heavy-duty, engineered thermoplastic material Offers the labor-saving feature of quick entry and integral clamping Eliminates the need to use a screwdriver to break open pry-outs The easy access entry-point serves as a wire clamp, eliminating time required to mechanically secure the wire to the box TP16511 TP16511 Diameter Mounting Method Capacity Cu. In. No. of Clamp Openings Std. Unit Pkg. Wt. Lbs. Per 100 4" Nails only 22.5 6 25 21 4" OCTAGON BOX AND ADJUSTABLE BAR SETS – 15.5 CUBIC INCH CAPACITY 11/2" DEEP BOX SETS Weight Limits: 35 lbs. at 16", 15 lbs. at 24" Cat. # TP376 TP372* TP377 TP368 Stud Std. Unit Pkg. Wt. Lbs. Per 100 FOR CONDUIT – NO CLAMPS TP372* 16" – 24" Stud Spacing Yes 25 85 FOR NONMETALLIC CABLE – WITH CLAMPS TP376 16" – 24" TP377 16" – 24" Yes — 25 25 104 102 25 100 FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP368 16" – 24" Yes *4" Octagon Box and Adjustable Bar Sets have 1/ 2" KOs for conduit US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 29 Steel Boxes Cat. # Steel Square Boxes 4" SQUARE OUTLET BOXES – 18.0 CUBIC INCH CAPACITY Steel Boxes 11/4" DEEP – FOR CONDUIT TP408 Cat. # TP408 30 Bracket — Description Drawn KNOCKOUTS Sides Bottom 12 – US: 1-866-764-5454 1/ 2" CAN: 1-800-265-0502 5– 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 50 61 Copyright© 2007 Cooper Crouse-Hinds Steel Square Boxes 4" SQUARE OUTLET BOXES – 22.0 CUBIC INCH CAPACITY (WELDED)† 21.0 CUBIC INCH CAPACITY (DRAWN) 11/2" DEEP – FOR CONDUIT Steel Boxes TP404/TP404PF TP425 TP467 TP410 TP412 TP839* TP414 TP469 TP830* TP405 TP418 TP423 KNOCKOUTS Metal Stud Sizes Bracket TP404 TP404 PF‡ TP425 TP423 TP405 TP410 TP412 TP414 TP418 TP467 TP469 — — — All — — — — — — ALL — — "VP" "VMS" — — — — "F", Set Flush — "VMS" Welded Welded Welded Welded Drawn Drawn Drawn Drawn Welded Welded Welded 8 – 1/ 2", 4 – 1/ 2" + 3/ 4" E 8 – 1/ 2", 4 – 1/ 2" + 3/ 4" E 6 – 1/ 2", 3 – 1/ 2" + 3/ 4" E 6 – 1/ 2", 3 – 1/ 2" + 3/ 4" E 4 – 1/ 2", 6 – 1/ 2" & 3/ 4" C 12 – 1/ 2" 8 – 3/ 4" 1 8 – / 2", 4 – 3/ 4" 6 – 1/ 2", 3 – 1/ 2" + 3/ 4" E 8 – 3/ 4" 6 – 3/ 4" Air Plenum TP830* TP839* — — — — Drawn Drawn 8 – 1/ 2", 4 – 3/ 4" 8 – 3/ 4" C Cat. # Description Sides Bottom 2 – 1/ 2" + 3/ 4" 2 – 1/ 2" + 3/ 4" 1/ 2", 2 – 1/ 2" + 3/ 4" 1/ 2", 2 – 1/ 2" + 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 5 – 1/ 2" 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 2 – 1/ 2", 2 – 1/ 2" + 3/ 4" 2 – 1/ 2", 2 – 1/ 2" + 3/ 4" 2 – 1/ 2", 2 – 1/ 2" + 3/ 4" 2 2 2 2 – – – – 1/ 2", 1/ 2", 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" E E E E E E E Std. Unit Pkg. Wt. Lbs. Per 100 50 50 25 25 50 50 50 50 25 50 25 72 72 82 81 67 67 67 67 84 72 81 50 50 72 72 *For Air Plenum (No Mounting Holes) † All welded 4" square outlet boxes have a raised dimple for ground screw ‡ TP404PF includes ground screw with pigtail lead US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 31 Steel Square Boxes 4" SQUARE OUTLET BOXES – 22.0 CUBIC INCH CAPACITY Steel Boxes 11/2" DEEP FOR NONMETALLIC CABLE – CLAMPS IN EACH END TP444 Cat. # Bracket TP449 TP444 TP446 TP445 "VMS" — "F", Set Flush "VP" TP449 TP446 KNOCKOUTS Sides Description Welded Welded Welded Welded 4 4 4 4 – – – – Cable, Cable, Cable, Cable, 2 4 2 2 – – – – 1/ 2", 1 1/ 2", 2 1/ 2", 1 1/ 2", 1 – – – – 1/ 2" & 1/ 2" & 1/ 2" & 1/ 2" & 3/ 4" E 3/ 4" E 3/ 4" E 3/ 4" E TP445 Bottom 1 1 1 1 – – – – 1/ 2" 1/ 2" 1/ 2" 1/ 2" Std. Unit Pkg. Wt. Lbs. Per 100 25 50 25 25 85 77 88 85 4" SQUARE OUTLET BOXES – 22.0 CUBIC INCH CAPACITY 11/2" DEEP FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP454 Cat. # Bracket TP459 TP454 TP456 TP461 "VMS" — "F", Set Flush "VP" 32 TP456 TP459 KNOCKOUTS Sides Description Welded Welded Welded Welded 4 4 4 4 – – – – US: 1-866-764-5454 Cable, Cable, Cable, Cable, 2 4 2 2 – – – – 1/ 2", 1 1/ 2", 2 1/ 2", 1 1/ 2", 1 CAN: 1-800-265-0502 – – – – 1/ 2" & 1/ 2" & 1/ 2" & 1/ 2" & 3/ 4" E 3/ 4" E 3/ 4" E 3/ 4" E TP461 Bottom 1 1 1 1 – – – – 1/ 2" 1/ 2" 1/ 2" 1/ 2" Copyright© 2007 Cooper Crouse-Hinds Std. Unit Pkg. Wt. Lbs. Per 100 25 50 25 25 89 81 92 89 Steel Square Boxes 4" SQUARE OUTLET BOXES – 30.3 CUBIC INCH CAPACITY 21/8" DEEP WITH CONDUIT KOs TP434 TP438 TP831* TP432 TP436 TP840* TP437 Steel Boxes TP403/TP403PF TP451 KNOCKOUTS Cat. # Bracket Description Sides 1/ 2", 1/ 2" Bottom 3/ 4" TP403 TP403 PF† TP432 TP436 TP434 TP438 TP451 TP437 — — — — — — "VMS" "VP" Welded Welded Welded Welded Drawn Drawn Welded Welded 4– & E 8– 8 – 1/ 2", 4 – 1/ 2" & 3/ 4" E 8 – 3/ 4" 8 – 1" 8 – 1/ 2", 4 – 3/ 4" 4 – 1/ 2", 6 – 1/ 2" & 3/ 4" C 6 – 1/ 2", 3 – 1/ 2" & 3/ 4" E 6 – 1/ 2", 3 – 1/ 2" & 3/ 4" E Air Plenum TP831* TP840* — — Drawn Drawn 8 – 1/ 2", 4 – 3/ 4" 8 – 3/ 4" 2 2 2 2 1/ 2", 1/ 2" 3/ 4" – 2– & – 1/ 2", 2 – 1/ 2" & 3/ 4" – 1/ 2", 2 – 1/ 2" & 3/ 4" – 1/ 2", 2 – 1/ 2" & 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 2 – 1/ 2", 2 – 1/ 2" & 3/ 4" 2 – 1/ 2", 2 – 1/ 2" & 3/ 4" Std. Unit Pkg. Wt. Lbs. Per 100 25 25 25 25 25 25 25 25 84 84 84 84 84 84 96 98 25 25 90 90 E E E E E E 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" *For Air Plenum (No Mounting Holes) †TP403PF includes ground screw with pigtail lead 21/8" DEEP – 30.3 CUBIC INCH CAPACITY FOR NONMETALLIC CABLE CLAMPS TP450 Cat. # Bracket TP450 TP452 — "VMS" TP452 KNOCKOUTS Sides Description Welded Welded 4 – Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" E 4 – Cable, 2 – 1/ 2", 1 – 1/ 2" & 3/ 4" E US: 1-866-764-5454 CAN: 1-800-265-0502 Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 25 25 90 104 Copyright© 2007 Cooper Crouse-Hinds 33 Steel Square Boxes 4" SQUARE OUTLET BOXES – 30.3 CUBIC INCH CAPACITY Steel Boxes 21/8" DEEP FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END TP431 Cat. # Metal Stud Sizes TP431 TP440 — All TP440 KNOCKOUTS Sides Bracket Description — "VMS" Welded Welded 4 – Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" E 4 – Cable, 2 – 1/ 2", 1 – 1/ 2" & 3/ 4" E Bottom Std. Unit Pkg. Wt. Lbs. Per 100 1 – 1/ 2" 1 – 1/ 2" 25 25 91 103 4" SQUARE TWO–DEVICE BOXES – 30.3 CUBIC INCH CAPACITY 21/8" DEEP TP391 Cat. # Bracket TP391 TP393 TP395 "VS" — — 34 TP393, TP395 Description Drawn Drawn Drawn Sides KNOCKOUTS Bottom 6 – 1/ 2", 3 – 3/ 4" 12 – 1/ 2" 8 – 1/ 2", 4 – 3/ 4" US: 1-866-764-5454 CAN: 1-800-265-0502 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" Std. Unit Pkg. Wt. Lbs. Per 100 25 25 25 95 84 84 Copyright© 2007 Cooper Crouse-Hinds Steel Square Boxes & Covers 4" SQUARE EXTENSION RINGS – 21.0 CUBIC INCH CAPACITY 11/2" DEEP WITH CONDUIT KNOCKOUTS Cat. # TP424 TP422 TP426 TP428 TP833* TP422 KNOCKOUTS Sides 12 – 1/ 2" 8 – 1/ 2", 4 – 1/ 2" + 3/ 4" E 8 – 3/ 4" 8 – 1/ 2", 4 – 3/ 4" 8 – 1/ 2", 4 – 3/ 4" 21/8" DEEP WITH CONDUIT KNOCKOUTS TP841* 8 – 1/ 2", 4 – 3/ 4" TP426 Steel Boxes TP424 TP428, TP833*, TP841* Bottom Std. Unit Pkg. Wt. Lbs. Per 100 — — — — — 50 50 50 50 50 46 50 46 46 48 — 25 66 *For Air Plenum (No Mounting Holes). Requires the use of TP854, purchased separately. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 35 Steel Square Boxes & Covers Features: Steel Boxes • Special spring steel allows for quick and easy tool-free installation. • Mounts on either side of the stud and can be easily removed or repositioned. • Sleek, low profile mounting bracket. • Far side support bracket provides support for boxes in 21/ 4" - 4" studs. • Far side support snaps easily onto box and is secured in place by plaster ring. • Available in shallow and deep boxes for use with conduit, armored/metal clad cable or Nonmetallic sheathed cable. • Steel bracket for lifting larger enclosures during installation supplied as standard. 4" SQUARE BRACKETED OUTLET BOXES TP404SSB TP444SSB TP454SSB TP450SSB TP431SSB TP563SSB TP403SSB KNOCKOUTS Cat. # Box Size TP404SSB TP444SSB TP454SSB TP403SSB TP450SSB TP431SSB TP563SSB 4" 4" 4" 4" 4" 4" 411/ 16" 36 Box Depth For Use With 11/ 2" 11/ 2" 11/ 2" 21/ 8" 21/ 8" 21/ 8" 21/ 8" Cubic Inch Capacity Conduit Nonmetallic Sheathed Cable Armored/Metal Clad Cable Conduit Nonmetallic Sheathed Cable Armored/Metal Clad Cable Conduit US: 1-866-764-5454 22.0 22.0 22.0 30.3 30.3 30.3 42.0 CAN: 1-800-265-0502 Sides 4– 4– 4– 4– 8 – 1/ 2", 4 – 1/ 2" & 3/ 4" E Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" 8 – 1/ 2", 4 – 1/ 2" & 3/ 4" E Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" 6 – 1/ 2", 6 – 1/ 2" & 3/ 4" C Copyright© 2007 Cooper Crouse-Hinds Bottom E E E E 2 – 1/ 2", 2 – 1/ 2" & 3/ 4" E 1 – 1/ 2" 1 – 1/ 2" 1 2 – / 2", 2 – 1/ 2" & 3/ 4" E 1 – 1/ 2" 1 – 1/ 2" 3 – 1/ 2", 2 – 3/ 4" Steel Square Boxes & Covers UNI-MOUNT™ COVERS The Unimount combines the features of a mounting device plate with those of a box support; giving you one universal plate for all of your needs. Specifically designed for use with metal or wood studs: Guide tabs ensure consistant alignment on stud Stud alignment hole ensures consistent mounting height Rigid bracket design elminates the need for far side support Available as a single or two device cover Universal design fits all 4" Square boxes Available in 1/ 2", 5/ 6" and 3/ 4" raised. Can be ordered preassembled to popular 4" square boxes. Fast and easy installation Can be used in multiple applications, resulting in less items to stock. Less labor intensive. Less material handling. No multiple assemblies to handle. Can be used in Class 2 communications outlets for low voltage without a box. • UL listed and CSA certified.* Steel Boxes • • • • • • • • • • • • • Single Gang Cat. # Description Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 3.8 4.3 5.5 50 50 50 43 46 50 6 8 9 50 50 50 38 52 54 — 1000 .5 SINGLE GANG 1/ 2" Raised TP30000 5/ 8" Raised TP31000 3/ 4" Raised TP32000 TWO GANG TP35000 TP36000 TP37000 Two Gang 1/ 2" Raised Raised 3/ 4" Raised 5/ 8" LOW PROFILE SCREWS TP710 L.P. Screws * CSA requires a far side support. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 37 Steel Square Boxes & Covers PRE-FABRICATED BOXES Cooper Crouse-Hinds Pre-Fabricated Boxes take labor savings to a whole new level! Includes the Uni-Mount™ cover attached to a 4" square box with ground screw and lead installed. Step 1 – Receive Uni-Mount™ Pre-Fabricated Box (Includes Uni-Mount cover attached to box with ground screw + lead installed) Steel Boxes Step 2 – Attach to wood or metal stud. You're done! TP404 11/ 2" Deep – Welded 22.0" Cubic Capacity TP403 21/ 8" Deep – Welded 22.0" Cubic Capacity TP436 21/ 8" Deep – Welded 30.3" Cubic Capacity Cat. # Description Pre-Fabricated Box, Cover, Ground Screw and Lead Assembly TP30404PF TP31404PF TP31436PF TP31467PF TP32404PF TP32454PF TP35404PF TP36404PF TP36467PF TP37404PF TP30403PF TP31403PF TP32403PF TP35403PF TP36403PF TP37403PF 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 11/ 2" Welded 21/ 8" Welded 21/ 8" Welded 21/ 8" Welded 21/ 8" Welded 21/ 8" Welded 21/ 8" Welded Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, Box, 1/ 2" 5/ 8" 5/ 8" 5/ 8" 3/ 4" 3/ 4" 1/ 2" 5/ 8" 5/ 8" 3/ 4" 1/ 2" 5/ 8" 3/ 4" 1/ 2" 5/ 8" 3/ 4" Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Single Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Raised Two Gang Uni-Mount Cover, ground screw and lead Note: The last three digits in the above catalog numbers designate the box type. See line art above. 38 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds TP467 11/ 2" Deep – Welded 22.0" Cubic Capacity Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 25.8 26.3 26.3 26.3 27.5 27.5 28.0 30.0 30.0 31.0 34.1 34.6 35.8 36.3 38.3 39.3 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 115 118 130 113 122 121 110 124 119 126 107 110 114 102 116 118 Steel Square Boxes & Covers PREASSEMBLED BOXES The Uni-Mount™ cover is available preassembled to four popular 4" square boxes for even greater labor savings and reduced costs. TP434 21/ 8" Deep – Welded 30.3" Cubic Capacity TP454 11/ 2" Deep – Welded 22.0" Cubic Capacity Cat. # Description Pre-Fabricated Box, Cover, Ground Screw and Lead Assembly For Conduit TP30414 TP31414 TP32414 TP35414 TP36414 TP37414 TP30434 TP31434 TP32434 TP35434 TP36434 TP37434 11/ 2" 11/ 2" 11/ 2" 11/ 2" 11/ 2" 11/ 2" 21/ 8" 21/ 8" 21/ 8" 21/ 8" 21/ 8" 21/ 8" Drawn Drawn Drawn Drawn Drawn Drawn Drawn Drawn Drawn Drawn Drawn Drawn Box Box Box Box Box Box Box Box Box Box Box Box assembled assembled assembled assembled assembled assembled assembled assembled assembled assembled assembled assembled to to to to to to to to to to to to 1/ 2" 5/ 8" 3/ 4" 1/ 2" 5/ 8" 3/ 4" 1/ 2" 5/ 8" 3/ 4" 1/ 2" 5/ 8" 3/ 4" Steel Boxes TP414 11/ 2" Deep – Welded 21.0" Cubic Capacity TP431 21/ 8" Deep – Welded 30.3" Cubic Capacity Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 24.8 25.3 26.5 27.0 29.0 30.0 34.1 34.6 35.8 36.3 38.3 39.3 25 25 25 25 25 25 25 25 25 25 25 25 110 113 117 105 119 121 127 130 134 122 136 138 24.8 25.3 26.5 27.0 29.0 30.0 34.1 34.6 35.8 36.3 38.3 39.3 25 25 25 25 25 25 25 25 25 25 25 25 114 117 121 109 123 125 134 137 141 129 143 145 Raised Single Gang Uni-Mount Cover Raised Single Gang Uni-Mount Cover Raised Single Gang Uni-Mount Cover Raised Two Gang Uni-Mount Cover Raised Two Gang Uni-Mount Cover Raised Two Gang Uni-Mount Cover Raised Single Gang Uni-Mount Cover Raised Single Gang Uni-Mount Cover Raised Single Gang Uni-Mount Cover Raised Two Gang Uni-Mount Cover Raised Two Gang Uni-Mount Cover Raised Two Gang Uni-Mount Cover For AC/MC Cable TP30454 11/ 2" Welded Box assembled to 1/ 2" Raised Single Gang Uni-Mount Cover TP31454 11/ 2" Welded Box assembled to 5/ 8" Raised Single Gang Uni-Mount Cover TP32454 11/ 2" Welded Box assembled to 3/ 4" Raised Single Gang Uni-Mount Cover TP35454 11/ 2" Welded Box assembled to 1/ 2" Raised Two Gang Uni-Mount Cover TP36454 11/ 2" Welded Box assembled to 5/ 8" Raised Two Gang Uni-Mount Cover TP37454 11/ 2" Welded Box assembled to 3/ 4" Raised Two Gang Uni-Mount Cover TP30431 21/ 8" Welded Box assembled to 1/ 2" Raised Single Gang Uni-Mount Cover TP31431 21/ 8" Welded Box assembled to 5/ 8" Raised Single Gang Uni-Mount Cover TP32431 21/ 8" Welded Box assembled to 3/ 4" Raised Single Gang Uni-Mount Cover TP35431 21/ 8" Welded Box assembled to 1/ 2" Raised Two Gang Uni-Mount Cover TP36431 21/ 8" Welded Box assembled to 5/ 8" Raised Two Gang Uni-Mount Cover TP37431 21/ 8" Welded Box assembled to 3/ 4" Raised Two Gang Uni-Mount Cover Note: The last three digits in the above catalog numbers designate the box type. See line art above. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 39 Steel Square Covers COVERS FOR 4" SQUARE BOXES – CUBIC INCH CAPACITY (SEE BELOW) Steel Boxes #8-32 screw used on covers TP472 TP474 TP478 TP473, TP475, TP476, TP477, TP479, TP483 TP850* TP854* Cat. # Description Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. TP472† TP474 TP478† TP473 TP476† TP477 TP475 TP479 TP483 Flat Blank Flat Blank, Open With Ears 23/ 4" Flat with 1/ 2", ko Raised 1/ 4", Open With Ears 23/ 4" Raised 1/ 2", Open With Ears 23/ 4" Raised 5/ 8", Open With Ears 23/ 4" Raised 3/ 4", Open With Ears 23/ 4" Raised 1", Open With Ears 23/ 4" Raised 11/ 4", Open With Ears 23/ 4" 50 50 50 50 50 50 25 25 25 31 21 31 23 26 27 31 34 37 — — — 1.3 4.0 5.0 6.0 7.0 8.5 Air Plenum TP850* TP854* Flat Blank Gasketed With Captive Screws Flat Ring Double Gasketed 25 25 31 12 — — *For Air Plenum (No Mounting Holes) †CSA Certified ONE DEVICE TP480 TP482, TP484, TP486, TP488, TP489, TP490 Cat. # Description Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. TP480 TP482 TP484 TP489 TP486 TP488 TP490 Flat 1/ 4" Raised 1/ 2" Raised 5/ 8" Raised 3/ 4" Raised 1" Raised 11/ 4" Raised 50 50 50 50 50 50 25 20 21 23 26 30 34 39 — 1.8 3.5 4.3 5.5 6.8 8.8 40 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Steel Square Covers TWO DEVICE TP494 TP494 TP496‡ TP498‡ TP499‡ TP500‡ TP501 TP502 Description Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. Flat Raised 1/ 2" Raised 5/ 8" Raised 3/ 4" Raised 11/ 4" Raised 1" Raised 50 50 50 50 50 25 25 12 13 18 22 24 31 30 — 3.0 6.0 8.0 9.0 14.0 11.7 1/ 4" Steel Boxes Cat. # TP496, TP488, TP499, TP500, TP501, TP502 ‡ Slotted design for use with 4" square box partitions SURFACE COVERS FOR 4" SQUARE BOXES – 5.5 CUBIC INCH CAPACITY RAISED 1/2" TP503 TP504 TP506 TP508 TP510 TP512 TP516 TP509 TP518 TP513 TP511 TP515 TP517 Cat. # Description TP503† TP504† TP506† TP508 TP510 TP512 TP507 TP514 TP519† TP516 TP509 TP518 TP513 TP511 TP515 TP517 Raised Blank For One Toggle Switch, One Single Receptacle 113/ 32" Dia. For One Toggle Switch, One Duplex Receptacle For Two Toggle Switches For Two Duplex Receptacles For One Toggle Switch For One 20 Amp, Single Receptacle 119/ 32" Dia. For One Single Receptacle 113/ 32" Dia. For One 30 Amp. Twist-Lock Single Receptacle 123/ 32" Dia. For One Duplex Receptacle For One 30 – 60 Amp. Receptacle (4-wire) 27/ 16" Dia. For One 30 – 50 Amp. Receptacle 29/ 64" Dia. For One GFCI Receptacle For Two GFCI Receptacles For One Toggle Switch, One GFCI Receptacle For One Duplex Receptacle, One GFCI Receptacle TP507 TP514 TP519 Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 35 31 31 35 26 35 37 34 37 31 23 34 31 26 31 26 † CSA Certified US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 41 Steel Square Boxes Steel Boxes TILE WALL COVERS FOR 4" SQUARE BOXES – CUBIC INCH CAPACITY (SEE BELOW) TP524 TP534 Applications: • Typically used with tile or brick Cat. # Description ONE DEVICE TP520 TP522 TP524 TP526 TP528 TP530 TWO DEVICE TP532 TP534 TP536 TP538 TP540 TP542 Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. 1/ 2" Raised Raised 1" Raised 11/ 4" Raised 11/ 2" Raised 2" Raised 50 50 50 25 25 25 30 36 40 46 50 62 3.7 5.5 7.4 9.2 11.0 14.7 1/ 2" 10 10 10 10 10 10 24 30 36 44 50 66 5 7.8 10.3 13 15.5 20.8 3/ 4" Raised Raised 1" Raised 11/ 4" Raised 11/ 2" Raised 2" Raised 3/ 4" 4" SQUARE BOX PARTITIONS TP860 Cat. # TP861 TP862 Std. Unit Pkg. Wt. Lbs. Per 100 FOR 11/2" DEEP BOX WITH SQUARE CUT TILE WALL TWO-GANG COVERS TP860 For 1/ 2", 3/ 4", 1" Raised Covers TP861 For 11/ 4", 11/ 2", 2" Raised Covers 25 25 13 18 FOR 21/8" DEEP BOX WITH SQUARE CUT TILE WALL TWO-GANG COVERS TP862 For 1/ 2", 3/ 4", 1" Raised Covers TP863 For 11/ 4", 11/ 2", 2" Raised Covers 25 25 16 21 42 Description TP863 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Steel Square Boxes 411/16" SQUARE OUTLET BOXES – 29.5 CUBIC INCH CAPACITY 11/2" DEEP WITH CONDUIT KOs Steel Boxes TP548 TP550 KNOCKOUTS Cat. # Sides Bottom Std. Unit Pkg. Wt. Lbs. Per 100 TP548 TP549 8 – 1/ 2", 4 – 3/ 4" 1 6 – / 2", 6 – 1/ 2" & 3/ 4" C 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 25 25 84 84 — 25 66 411/16" SQUARE EXTENSION RING TP550 8 – 1/ 2", 4 – 3/ 4" US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 43 Steel Square Boxes 411/16" SQUARE OUTLET BOXES – 42.0 CUBIC INCH CAPACITY Steel Boxes 21/8" DEEP WITH CONDUIT KOs TP563 TP554 TP842* TP556 TP832* TP558 TP835* TP560 TP836* TP562 TP557 TP564 TP837* KNOCKOUTS Cat. # Brackets TP563 TP554 TP556 TP558 TP560 TP562 TP557 Air Plenum TP835* TP836* TP842* TP832* 411/16", TP564 — — — — — "VS" — 6– & C 8 – 3/ 4" 8 – 1/ 2", 4 – 3/ 4" 4 – 3/ 4", 4 – 1" 8 – 1" 4 – 1 – 1/ 4" 4 – 1/ 2", 5 – 1/ 2" & 3/ 4" C 3 3 3 3 3 3 3 – – – – – – – — — — — 4 – 3/ 4", 4 – 1" 8 – 1" 12 – 3/ 4" 8 – 1/ 2", 4 – 3/ 4" 3 3 3 3 – – – – 1/ 2", — 6– 1/ 2", 1/ 2" Bottom 1/ 2", SQUARE EXTENSION RING — Air Plenum TP837* Sides 3/ 4" 2 2 2 2 2 2 2 – – – – – – – 3/ 4" 2 2 1/ 2", 2 1/ 2", 2 – – – – 3/ 4" 1/ 2", 1/ 2", 1/ 2", 1/ 2", 1/ 2", 1/ 2", 1/ 2", 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" Std. Unit Pkg. Wt. Lbs. Per 100 25 25 25 25 25 25 25 104 104 104 104 104 104 120 25 25 25 25 115 115 115 115 8 – 1/ 2", 4 – 3/ 4" — 25 84 8 – 1/ 2", 4 – 3/ 4" — 25 115 *For Air Plenum (No Mounting Holes) Note: 44 TP837 requires the use of TP852, purchased separately. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Steel Square Covers 411/16" SQUARES COVERS – CUBIC INCH CAPACITY (SEE BELOW) TP569, TP570, TP571, TP573, TP575 TP574, – TP582, TP529, TP531 TP584, TP586, TP589, TP593, TP541, TP543 TP851* TP852* Cat. # Description Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. TP568† TP569 TP570 TP571 TP572† TP573 TP575 Flat Blank 1/ 2" Raised, With Ears 23/ 4" Raised 5/ 8", With Ears 23/ 4" 3/ 4" Raised, With Ears 23/ 4" Flat, With 1/ 2" KO 1" Raised, With Ears 23/ 4" 11/ 4" Raised, With Ears 23/ 4" 25 25 25 25 25 25 25 40 36 38 40 40 44 48 — 3.3 3.8 5.0 — 7.0 9.0 Air Plenum TP851* TP852 Flat Blank Gasketed Captive Screws Flat Ring Double Gasketed 50 25 42 20 — — ONE DEVICE TP574 TP576 TP578 TP579 TP580 TP582 TP529 TP531 1/ 4" Raised Raised 3/ 4" Raised 5/ 8" Raised 1" Raised 11/ 4" Raised 11/ 2" Raised 2" Raised 25 25 25 25 25 25 25 25 32 36 42 39 46 52 64 76 1.8 3.3 5.0 4.3 6.8 8.8 11.3 15.0 TWO DEVICE TP590 TP583 TP584 TP587 TP586 TP589 TP593 TP541 TP543 Flat 1/ 4" Raised 1/ 2" Raised 5/ 8" Raised 3/ 4" Raised 1" Raised 11/ 4" Raised 11/ 2" Raised 2" Raised 25 25 25 25 25 25 25 25 25 21 26 30 32 34 38 42 63 79 — 3.0 6.0 8.0 8.8 11.7 14.0 18.8 24.5 1/ 2" Steel Boxes TP568 *For Air Plenum (No Mounting Holes) †CSA Certified US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 45 Steel Square Covers 411/16" SQUARE SURFACE COVERS – 9.0 CUBIC INCH CAPACITY DEEP Steel Boxes 1/ 2" TP720 TP722 TP724 TP730 TP736 TP726 TP728 TP732 TP734 TP738 Cat. # Description TP720 TP722 TP724 TP730 TP736 TP726 TP728 TP732 TP734 TP738 TP741 For One Toggle Switch For One Duplex Receptacle For One Single Receptacle 113/ 32" Dia. For One 20 Amp Single Receptacle 1.620" Dia. For One 1.730" Dia. Power Outlet For Two Toggle Switches For Two Duplex Receptacles For One 2.125" Dia. Range/Dryer Receptacle For One 2.480" Dia. Power Outlet For One Ground Fault Interrupter For Two GFI Receptacles 46 US: 1-866-764-5454 CAN: 1-800-265-0502 Std. Unit Pkg. Wt. Lbs. Per 100 10 10 10 10 10 10 10 10 10 10 10 52 49 53 50 51 52 44 48 45 45 43 Copyright© 2007 Cooper Crouse-Hinds Steel Utility Boxes & Covers UTILITY BOXES – CUBIC INCH CAPACITY (SEE BELOW) 4" LONG × 21/8" WIDE Cat. # TP591 Bracket TP592, TP600, TP602 KNOCKOUTS Sides Bottom TP598 TP594, TP596, TP604, TP606, TP595 (41/8" × 23/8") Std. Unit Pkg. Wt. Lbs. Per 100 3 – 1/ 2" 50 40 3 – 1/ 2" 3 – 1/ 2" 50 50 42 51 50 36 50 50 50 50 50 60 17/8" DEEP EXTENSION RINGS – 13.0 CUBIC INCH CAPACTIY TP600 — — 8 – 1/ 2" — TP602 — 6 – 3/ 4" 50 50 41 41 21/8" DEEP – 14.5 CUBIC INCH CAPACITY TP604 — 8 – 1/ 2" TP606 — 6 – 3/ 4" TP608* "S", Set 1/ 2" 5 – 1/ 2" 3 – 1/ 2" 3 – 1/ 2" 3 – 1/ 2" 50 50 50 56 56 66 21/8" DEEP – 18.5 CUBIC INCH CAPACITY TP595 — 8 – 1/ 2" 3 – 1/ 2" 50 60 11/4" DEEP – 8.5 CUBIC INCH CAPACITY TP647 — 8 – 1/ 2" 11/2" DEEP – 10.3 CUBIC INCH CAPACITY TP588 — 8 – 1/ 2" TP591 "F", Set 1/ 4" 5 – 1/ 2" 11/2" DEEP EXTENSION RINGS – 10.3 CUBIC INCH CAPACITY — TP592 — 8 – 1/ 2" 17/8" DEEP – 13.0 CUBIC INCH CAPACITY TP594 — 8 – 1/ 2" TP596 — 6 – 3/ 4" TP598 5 – 1/ 2" "S", SET 1/ 2" 3 – 1/ 2" 3 – 1/ 2" 3 – 1/ 2" Steel Boxes TP588, TP647 Covers TP608 TP610 TP612 TP613 Cat. # Description TP608* TP610* TP612* TP613* TP614* TP616* TP618* Blank For 20 and 30 AMP, Twist Lock, 119/ 32" Diameter Single Receptacle, 113/ 32" Diameter For GFCI Device 1/ 2" KO Duplex Receptacle One Toggle Switch TP614 TP616 TP618 Std. Unit Pkg. Wt. Lbs. Per 100 100 100 100 100 100 100 100 10 9 9 7 10 8 10 *CSA Certified US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 47 Steel Specialty Boxes Steel Boxes 4" OCTAGON CONCRETE BOXES AND HUNG CEILING BOXES* TP620, TP622, TP628 TP635, TP636, TP644 TP623, TP624 (bars not included) TP348 KNOCKOUTS Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. & 3/ 4" Single Row & 3/ 4" Single Row 1/ 2" & 3/ 4" Single Row 1/ 2" Double Row 1/ 2" & 3/ 4" Double Row 1/ 2" & 3/ 4" Double Row 25 25 20 20 20 20 60 72 85 93 93 113 23.0 29.0 35.0 43.0 43.0 47.0 HUNG CEILING BOXES (WITH TP650 COVER, ORDER BARS SEPARATELY) 1/ 2" Double Row TP623 31/ 2" 1/ 2" & 3/ 4" Double Row TP624 31/ 2" 20 20 93 93 43.0 43.0 BARS FOR HUNG CEILING BOXES TP348 30" bars (Bars Sold Separately) 40 60 – Cat. # Depth TP620 TP622 TP628 TP635 TP636 TP644 2" 21/ 2" 3" 31/ 2" 31/ 2" 4" 1/ 2" 1/ 2" *Weight limit for 4" octagon concrete boxes is 50lbs. Not suitable for fans. CONCRETE BOX PLATES TP648 TP649 Cat. # Description TP648 TP649 TP650 TP652 No Stud 3 – 1/ 2" & 2 – 3/ 4" KOs Flat, Blank 3/ 8" Stud 2 – 1/ 2" & 2 – 3/ 4" KOs Single Receptacle 48 US: 1-866-764-5454 CAN: 1-800-265-0502 TP650 TP652 Std. Unit Pkg. Wt. Lbs. Per 100 50 50 50 50 28 28 33 24 Copyright© 2007 Cooper Crouse-Hinds Steel Masonry Boxes MASONRY BOXES 21/2" DEEP × 33/4" HIGH 1/ 2" AND 3/ 4" CONCENTRIC KOs Steel Boxes TP682 KNOCKOUTS Cat. # Gang Width Each Side Each End Bottom Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. TP682 TP683 TP684 TP685 TP686 TP687 1 2 3 4 5 6 115/ 16" 33/ 4" 59/ 16" 73/ 8" 93/ 16" 11" 2 2 2 2 2 2 1 2 3 4 5 6 2 4 6 8 10 12 20 10 5 5 5 1 70 103 129 165 189 230 15.5 31.0 46.5 62.0 77.5 93.0 MASONRY BOXES 31/2" DEEP × 33/4" HIGH 1/ 2" AND 3/ 4" CONCENTRIC KOs TP690 KNOCKOUTS Cat. # Gang Width Each Side Each End Bottom Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. TP690 TP691 TP692 TP693 TP694 TP695 1 2 3 4 5 6 115/ 16" 33/ 4" 59/ 16" 73/ 8" 93/ 16" 11" 2 2 2 2 2 2 2 4 6 8 10 12 2 4 6 8 10 12 20 10 10 5 5 1 84 120 155 207 235 287 22.0 44.0 66.5 88.0 110.0 132.0 MASONRY BOX PARTITIONS Cat. # Description TP820 TP821 Nonmetallic Partition for 21/ 2" Deep Masonry Boxes Nonmetallic Partition for 31/ 2" Deep Masonry Boxes US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Std. Unit Pkg. Wt. Lbs. Per 100 25 25 3 4 49 Steel Gang Boxes GANG BOXES Steel Boxes 15/8" DEEP × 41/2" HIGH 1/ 2" & 3/ 4" KOs TP630 TP640 KNOCKOUTS Cat. # Gang Cubic Inches TP629 TP630 TP631 TP640 TP641 2 3 4 5 6 45 58 70 85 95 Width Each Side 613/ 16" 85/ 8" 107/ 16" 121/ 4" 141/ 16" 2 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 2 – 3/ 4" 3 – 1/ 2", 3 – 3/ 4" 4 – 1/ 2", 3 – 3/ 4" 4 – 1/ 2" 4 – 3/ 4" Each End 1 1 1 1 1 – – – – – 1/ 2", 1 1 1/ 2", 1 1/ 2", 1 1/ 2", 1 1/ 2", – – – – – Bottom 3/ 4" 3 6 6 6 6 3/ 4" 3/ 4" 3/ 4" 3/ 4" – – – – – 1/ 2", 2 4 1/ 2", 4 1/ 2", 4 1/ 2", 4 – – – – – 1/ 2", 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" Std. Unit Pkg. Wt. Lbs. Per 100 5 5 5 1 1 45 58 70 85 95 Std. Unit Pkg. Wt. Lbs. Per 100 10 10 5 5 5 147 183 216 263 282 GANG BOXES 21/2" DEEP × 41/2" HIGH 3/ 4" & 1" KOs TP871 TP873 KNOCKOUTS Cat. # Gang Cubic Inches TP870 TP871 TP872 TP873 TP874 2 3 4 5 6 71 90 110 132 150 Width 613/ 16" 85/ 8" 107/ 16" 121/ 4" 141/ 16" Each Side 2 4 2 3 3 – – – – – 3/ 4", 1 1 3/ 4", 2 3/ 4", 2 3/ 4", 3 3/ 4", – – – – – 1" 1" 1" 1" 1" Each End 1 1 1 1 1 – – – – – 3/ 4", 1 1 3/ 4", 1 3/ 4", 1 3/ 4", 1 3/ 4", – – – – – Bottom 1" 1" 1" 1" 1" 3 6 6 6 6 – – – – – 1/ 2", 2 4 1/ 2", 4 1/ 2", 4 1/ 2", 4 1/ 2", – – – – – 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" GANG BOX PARTITIONS TP876 Cat. # Description TP876 TP877 For 15/ 8" Deep Box For 21/ 2" Deep Box 50 TP877 US: 1-866-764-5454 CAN: 1-800-265-0502 Std. Unit Pkg. Wt. Lbs. Per 100 25 50 19 24 Copyright© 2007 Cooper Crouse-Hinds Steel Gang Box Covers GANG BOX COVERS RAISED 13/16" FOR PLASTER Steel Boxes TP653 TP667 Cat. # Gang Length Std. Unit Pkg. Wt. Lbs. Per 100 Capacity Cu. In. TP657 TP653 TP655 TP661 TP667 2 3 4 5 6 7" 813/ 16" 105/ 8" 127/ 16" 141/ 4" 5 5 5 5 5 53 60 66 75 85 8.5 13.5 18.3 23.0 28.3 GANG BOX COVERS, FLAT, BLANK TP803 TP806 Cat. # Gang Length Std. Unit Pkg. Wt. Lbs. Per 100 TP802 TP803 TP804 TP805 TP806 2 3 4 5 6 7" 813/ 16" 105/ 8" 127/ 16" 141/ 4" 5 5 5 1 1 66 85 94 122 132 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 51 PVC Switch Boxes Applications: Cooper Crouse-Hinds nonmetallic switch and outlet boxes are used: • In branch circuit wiring as a splice point • To mount wiring devices such as switches and receptacles • To provide mechanical protection for wiring systems and electrical devices PVC Boxes Features: • Available for use with wood or metal studs to meet any construction preference • Quick entry feature on all nonmetallic boxes offers labor savings – no need to break out knockouts – simply push the nonmetallic cable into the box. No tools are required. No need to remove knockouts. • Unique configuration of this quick entry feature on single gang boxes provides a self-feeding feature that eliminates the need to reach inside the box to pull the wire out. • Integral labor saving clamping feature on two, three & four gang boxes. The multiple gang box unique entry also serves as a clamp, eliminating the need to mechanically secure the cable inside the box. There are no separate clamps or screws to install or tighten. Each entry into the multiple gang boxes has the quick entry feature allowing the installer to simply push the cable into the box without the need for tools or removal of knock-outs, so the cable can be inserted where it is required. Standard Materials: • PVC-Polyvinyl Chloride compound Certifications and Compliances: • UL Listed File No. E102328 • Classified for use in fire rated (2 HR) wall or ceiling. Fire Rating No. R9933. SWITCH BOXES – ANGLED NAILS TP1600 Cat. # TP1600 TP1800 TP2000 TP2300 TP1800 TP2000 Bracket or Nails Capacity Cu. In. H W Nails Nails Nails Nails 16.0 18.0 20.3 22.5 33/ 4" 33/ 4" 33/ 4" 33/ 4" 21/ 4" 21/ 4" 21/ 4" 21/ 4" TP2300 D Std. Unit Pkg. Wt. Lbs. Per 100 21/ 2" 23/ 4" 33/ 16" 37/ 16" 100 100 100 50 21 23 25 27 For Labor Savings Speed-Mount™ Switchboxes, see page 56 52 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds PVC Switch Boxes SWITCH BOXES – INTEGRAL CLAMPS TP2030 (For Wood or Metal Studs) Bracket or Nails Capacity Cu. In. H W D Std. Unit Pkg. Wt. Lbs. Per 100 Swing Clips & Integral Clamps Side Bracket (5/ 8" offset) Face Bracket (1/ 2" offset) 16.0 20.3 20.3 35/ 8" 311/ 16" 311/ 16" 25/ 16" 21/ 4" 21/ 4" 23/ 4" 33/ 16" 33/ 16" 50 50 50 20 24 24 Cat. # TP1690 TP2020 TP2030 TP2020 (For Wood or Metal Studs) PVC Boxes TP1690 (Old Work) 3" DEEP SWITCH BOXES – TWO GANG TP3490 (Old Work) Cat. # TP3490 TP3600 TP3630* TP3635* TP3600 TP3630 TP3635 Bracket or Nails Capacity Cu. In. H W D Std. Unit Pkg. Wt. Lbs. Per 100 Swing Clips Nails Brackets Brackets & Nails 34.0 36.0 36.0 36.0 39/ 16" 33/ 4" 33/ 4" 33/ 4" 4" 4" 4" 4" 33/ 16" 3" 3" 3" 25 25 25 25 29 37 37 39 *Face Bracket on PVC Boxes are offset 1/ 2" unless stated otherwise 211/16" DEEP SWITCH BOXES – THREE GANG TP4600 Cat. # TP4600 TP4630* TP4635* TP4630 TP4635 Bracket or Nails Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 Nails Brackets Brackets & Nails 46.0 46.0 46.0 20 20 20 45 43 46 For Labor Savings Speed-Mount™ Switchboxes, see page 56 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 53 PVC Switch Boxes 211/16" DEEP SWITCH BOXES – FOUR GANG PVC Boxes TP6100 TP6135 Bracket or Nails Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 Nails Nails & Brackets Brackets & Bar Support 61.0 61.0 61.0 4 4 4 65 66 87 Cat. # TP6100† TP6135*† TP6180*† TP6180 *Face Bracket on PVC Boxes are offset 1/ 2" unless otherwise stated †Not 2-Hour Fire Rated LOW VOLTAGE PARTITION – TWO, THREE OR FOUR GANG PVC TP1000 Cat. # TP1000 Bracket or Nails Capacity Cu. In. Std. Unit Pkg. Master Pkg. Wt. Lbs. Per 100 — — 20 120 3 4" SQUARE WITH INTEGRAL CLAMPS – 20.3 CUBIC INCH CAPACITY 15/8" DEEP TP1900 Cat. # TP1900 TP1930 54 TP1930 Bracket Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 — "F" Bracket 20.3 20.3 50 50 26 40 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds PVC Switch Boxes 4" SQUARE PVC DEVICE COVERS TP1009 TP1009 TP1010 TP1020 TP1013 TP1014 TP1023 TP1024 TP1020 TP1013, TP1014 TP1023, TP1024 Raised Capacity Cu. In. Std. Unit Pkg. Wt. Lbs. Per 100 — — — 1/ 2" 5/ 8" 1/ 2" 5/ 8" — — — 3.8 4.8 5.8 7.0 50 50 50 50 50 50 50 9 6 4 8 8 8 8 PVC Boxes Cat. # TP1010 ROUND BLANK COVER – PVC 43/4" DIA. (FOR 31/2" AND 4" ROUND CEILING BOXES) TP1040, TP1045 Cat. # Color Screws Std. Unit Pkg. Wt. Lbs. Per 100 TP1040 TP1045* Gray White — White 100 100 10 12 *TP1045 includes two white-headed wood and two #8-32" machine screws. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 55 Nonmetallic Ceiling Boxes Nonmetallic Switchboxes New! Speed-Mount™ Switchboxes Features: The labor saving Speed-Mount device installation feature is simple and easy to use. The device is attached by simply pressing the device mounting screw into the device hole in the box and turning the screw to lock it in place. The spring steel clip locks the screw securely in place. To remove the device, simply unscrew the screw in the traditional manner. • Available for use with wood or metal stud to meet any construction preference • Quick entry feature on all nonmetallic boxes offers labor savings – no need to break out knockouts – simply push the nonmetallic cable into the box. No tools are required. No need to remove knockouts. • Unique configuration of this quick entry feature on single gang boxes provides a self-feeding feature that eliminates the need to reach inside the box to pull the wire out. • Integral labor saving clamping feature on two, three & four gang boxes. The multiple gang box unique quick entry also serves as a clamp, eliminating the need to mechanically secure the cable inside the box. There are no separate clamps or screws to install or tighten. Each entry into the multiple gang boxes has the quick entry feature allowing the installer to simply push the cable into the box without the need for tools or removal of knockouts, so the cable can be inserted where it is required. • Speed-Mount Switchboxes offer simple, labor saving press installation of devices. The device is attached by simply pressing the device mounting screw into the device hole and turning the screw to lock it in place. The spring steel clip locks the screw securely in place. Our new Speed-Mount™ SWITCHBOXES provide significant labor savings through our quick cable entry feature and express device installation feature. Applications: Cooper Crouse-Hinds nonmetallic Speed-Mount Switchboxes are used: • In branch circuit wiring as a splice point • To mount wiring devices such as switches, receptacles, GFCI’s, dimmers etc. • To provide mechanical protection for wiring systems and electrical devices Cat. # TP1802 TP1832 TP2002 TP2302 TP2332 TP3602 TP3632 TP4602 TP4632 TP6102 TP6132 Standard Materials: • PVC – Polyvinyl Chloride compound Certifications and Compliances: • UL Listed • Classified for use in fire rated (2 HR) wall or ceiling Capacity Cu. In. Description Bracket or Nails Std. Unit Qty. 18.0 18.0 20.0 22.5 22.5 36.0 36.0 54.0 54.0 72.0 72.0 single gang single gang single gang single gang single gang 2 gang box 2 gang box 3 gang box 3 gang box 4 gang box 4 gang box nails bracket nails nails bracket nails bracket nails bracket nails bracket 100 100 100 50 50 25 25 20 20 4 4 box box box box box Far Side Support – For use with Speed-Mount™ Switchboxes Applications: How to use: • Far Side Support is designed for use with Speed-Mount™ switchboxes used with either wood or metal studs to provide a quick, easy economical way for far side support. • The multi-gang Speed-Mount™ boxes have a molded-in-hole in the back for attaching the TPFSS. The molded-in-hole has two flats as you look at the back of the box. There are also two flats on the TPFSS. To install, simply align the flats and push the TPFSS into the hole. Turn 1/ 4 turn to lock into place. • The TPFSS is designed for use with steel studs with a depth of 35/ 8". For use with 2 × 4 wood studs, simply break off the tip at the notch of the TPFSS using a pair of pliers. Cat. # Capacity Cu. In. TPFSS — 56 Description — US: 1-866-764-5454 CAN: 1-800-265-0502 Bracket or Nails Std. Unit Qty. — 100 Copyright© 2007 Cooper Crouse-Hinds Ceiling Boxes 31/2" NONMETALLIC CEILING BOXES 27/8" DEEP Weight limit is 50 lbs for fixture except where indicated. Cat. # TP16200† TP16201† TP16310* TP16311* TP16307*‡ TP16308*‡ TP16317* TP16318* TP16310 TP16311 TP16307 TP16308 Nonmetallic Ceiling Boxes TP16200, (TP16201 – 21/8" Deep) Old Work TP16317 TP16318 Clamps Ground Plate Bracket/Bar Hgr. Capacity Cu. In. No. of Clamp Openings Std. Unit Pkg. Wt. Lbs. Per 100 Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes — Yes — Yes Snap Snap Nails Nails 14"–22-1/2" 14"–22-1/2" "B" "B" 16.0 16.0 19.3 19.3 19.3 19.3 19.3 19.3 4 4 4 4 4 4 4 4 50 50 50 50 25 25 50 50 27 29 18 20 57 59 26 20 *Nail Bracket is set 19/ 16" back from the face of the box. † Weight limit 15lbs for ceiling mounted fixtures and 6lbs for wall mounted fixtures. ‡ Weight limit 15lbs at 24" stud spacing, 35lbs at 16" stud spacing. LAMPHOLDER TP16098 TP16099 Standard Materials: • Plastic molded of heat and impact resistant material that prevents discoloring and reduces breakage Cat. # Description TP16098 TP16099 Lampholder, Pull Chain Lampholder, Keyless, feed thru US: 1-866-764-5454 CAN: 1-800-265-0502 Std. Unit Pkg. Wt. Lbs. Per 100 50 50 29 23 Copyright© 2007 Cooper Crouse-Hinds 57 Ceiling Boxes 4" NONMETALLIC CEILING BOXES Nonmetallic Ceiling Boxes Weight limit is 50 lbs for fixture except where indicated TP16111, TP16110 TP16012, TP16112 TP16007, TP16107 TP16002 TP16022, TP16122 Clamps Ground Plate Bracket/Bar Hgr. Capacity Cu. In. No. of Cable Pry-outs Std. Unit Pkg. Wt. Lbs. Per 100 11/2" DEEP TP16002 TP16003 TP16012 TP16013 TP16007 TP16008 TP16022* TP16023* Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes — Yes — Yes — — "V" "V" "B" "B" 14"–22-1/2" 14"–22-1/2" 14.8 14.8 14.8 14.8 14.8 14.8 14.8 14.8 4 4 4 4 4 4 4 4 50 50 50 50 50 50 25 25 12 14 24 26 26 28 56 58 21/4" DEEP TP16111 TP16110 TP16112 TP16113 TP16107 TP16108 TP16122* TP16123* Yes Yes Yes Yes Yes Yes Yes Yes — Yes — Yes — Yes — Yes Nails Nails "V" "V" "B" "B" 14"–22-1/2" 14"–22-1/2" 22.5 22.5 20.8 20.8 20.8 20.8 20.8 20.8 4 4 4 4 4 4 4 4 50 50 50 50 50 50 20 20 19 21 27 29 28 30 59 61 Cat. # *Weight limit 15 lbs at 24" stud spacing, 35 lbs at 16" stud spacing. 4" NONMETALLIC CEILING FAN BOXES With clamps for nonmetallic cable. All mounting hardware supplied, suitable for support of fans weighing up to 35 lbs. TP16511 Cat. # TP16511 58 Diameter Mounting Method Capacity Cu. In. No. of Clamp Openings Std. Unit Pkg. Wt. Lbs. Per 100 4" Nails only 20.8 6 25 21 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Weatherproof Outlet Boxes Cooper Crouse-Hinds weatherproof products are manufactured in compliance with U.L. requirements for weatherproof boxes and covers and meet U.L. Standard #514A. Cooper Crouse-Hinds lighting products comply with the U.L. requirements of standard UL 1598 and are suitable for wet locations. Cooper Crouse-Hinds weatherproof boxes and covers are individually shrink-wrapped. Cooper Crouse-Hinds weatherproof cast aluminum boxes are lugged except where noted and are provided with plugs. The self-closing weatherproof covers are zinc die-cast. The weatherproof lampholders have porcelain sockets and are rated up to 150 watts and have 81/ 2" wire leads. Cooper Crouse-Hinds weatherproof products are rust and corrosion resistant made of rugged die-cast construction. Cooper Crouse-Hinds weatherproof products are provided with necessary gaskets, plugs and screws, making installation trouble free. Vaporite fixtures are die-cast aluminum and the screw-on guards are die-cast zinc, with Allen-Head set screws for locking in place. The fixtures also have a neoprene gasket and porcelain clip-in socket. All products are powder coat painted and various colors are available. SINGLE GANG WEATHERPROOF OUTLET BOXES – 18.0 CUBIC INCH CAPACITY – 2" DEEP Weatherproof CAST ALUMINUM – UL LISTED FOR WET LOCATIONS TP7010 – TP7018 TP7026, TP7034 TP7042, TP7050 Cat. # Description Outlet Holes TP7010 TP7011 TP7012 TP7018 TP7026 TP7034 TP7042 TP7050 TP7058 TP7066 TP7071 With Lugs With Lugs With Lugs With Lugs With Lugs With Lugs With Lugs With Lugs Side Entry, With Lugs Side Entry, With Lugs Horiz. Mounting, With Lugs 3 3 3 3 4 4 5 5 5 5 4 – – – – – – – – – – – 1/ 2" 1/ 2" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" TP7058, TP7066 TP7071 Color Std. Unit Carton Wt. Lbs. Per 100 Gray White Bronze Gray Gray Gray Gray Gray Gray Gray Gray 50 50 50 50 50 50 50 50 50 50 50 58.3 58.3 58.3 58.3 58.3 58.3 58.3 58.3 58.3 58.3 58.3 SINGLE GANG WEATHERPROOF OUTLET BOXES – 24.0 CUBIC INCH CAPACITY – 25/8" DEEP CAST ALUMINUM – UL LISTED FOR WET LOCATIONS TP7074, TP7078, TP7082 Cat. # Description Outlet Holes Color Std. Unit Carton Wt. Lbs. Per 100 TP7074 TP7078 TP7082 With Lugs With Lugs With Lugs 3 – 1/ 2" 3 – 3/ 4" 3 – 1" Gray Gray Gray 25 25 25 80 80 80 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 59 Weatherproof Outlet Boxes TWO GANG WEATHERPROOF OUTLET BOXES – 30.5 CUBIC INCH CAPACITY 2" DEEP, ALL TWO GANG BOXES HAVE 2 MOUNTING LUGS AS STANDARD CAST ALUMINUM – UL LISTED FOR WET LOCATIONS Weatherproof TP7086 – TP7090 TP7094, TP7098 Cat. # Description TP7086 TP7087 TP7088 TP7090 TP7094 TP7098 TP7102 TP7106 TP7110 TP7114 TP7118 TP7122 3 3 3 3 4 4 5 5 7 7 5 5 – – – – – – – – – – – – 1/ 2" 1/ 2" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" 3/ 4" Holes Holes Holes Holes Holes Holes Holes Holes Holes Holes Holes Holes TP7102, TP7106 TP7110, TP7114 TP7118, TP7122 Std. Unit Carton Color Wt. Lbs. Per 100 10 10 10 10 10 10 10 10 10 10 10 10 Gray White Bronze Gray Gray Gray Gray Gray Gray Gray Gray Gray 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 83.3 TWO AND THREE GANG DEEP WEATHERPROOF OUTLET BOXES 25/8" DEEP, ALL BOXES ARE STANDARD WITH MOUNTING LUGS CAST ALUMINUM – UL LISTED FOR WET LOCATIONS TP7126, TP7130, TP7134 TP7137, TP7138, TP7142 TP7143, TP7144 Std. Unit Carton Capacity Cu. In. Wt. Lbs. Per 100 TWO GANG DEEP WEATHERPROOF OUTLET BOXES TP7126 Gray 5 – 1/ 2" Holes Gray TP7130 5 – 3/ 4" Holes TP7134 5 – 1" Holes Gray Gray TP7137 7 – 1/ 2" Holes TP7138 Gray 7 – 3/ 4" Holes TP7142 7 – 1" Holes Gray 6 6 6 6 6 6 37 37 37 37 37 37 140 140 140 140 140 140 THREE GANG DEEP WEATHERPROOF OUTLET BOXES TP7143 Gray 7 – 3/ 4" Holes TP7144 7 – 1" Holes Gray 5 5 59 59 159 159 Cat. # 60 Description Color US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Weatherproof Outlet Boxes ONE & TWO GANG WEATHERPROOF EXTENSIONS 1" DEEP, DIE-CAST ALUMINUM EXTENSION RING GASKET AND MOUNTING SCREWS INCLUDED WITH COVER UL LISTED FOR WET LOCATIONS TP7120 TP7123 Description Color TP7120 TP7123 Single Gang Two Gang Gray Gray 25 10 Capacity Cu. In. Wt. Lbs. Per 100 9 10 27.2 27.2 Weatherproof Cat. # Std. Unit Carton EXTENSION ADAPTER DIE-CAST ALUMINUM, UL LISTED FOR WET LOCATIONS 3 CLOSURE PLUGS, MOUNTING SCREW AND GASKET INCLUDED WITH COVER Cat. # Description Color Std. Unit Carton Capacity Cu. In. Wt. Lbs. Per 100 TP7173 TP7174 4 – 1/ 2" Holes 4 – 3/ 4" Holes Gray Gray 25 25 13.0 13.0 23.6 27.8 4" ROUND WEATHERPROOF OUTLET BOXES – 15.5 CUBIC INCH CAPACITY 11/2" DEEP, DIE-CAST ALUMINUM, UL LISTED FOR WET LOCATIONS 4 CLOSURE PLUGS AND GROUND SCREW INCLUDED WITH BOX GASKET AND 2 MOUNTING SCREWS INCLUDED WITH COVER Cat. # TP7146 TP7148 TP7149 TP7150 TP7158 Side Holes 4 4 4 4 – – – – Back Hole Std. Unit Carton Color Wt. Lbs. Per 100 1/ 2" 1/ 2" 1/ 2" 1/ 2" 25 25 25 25 50 Gray White Bronze Gray Gray 79.2 79.2 79.2 79.2 20.8 24 24 Gray Gray 100 100 Gray 58.3 1/ 2" 1/ 2" 3/ 4" 3/ 4" Blank Cover Plate WITH BLANK PLATE TP7147 4 – 1/ 2" TP7151 4 – 3/ 4" 1/ 2" 3/ 4" 2" DEEP ROUND WEATHERPROOF OUTLET BOX EXTENSION (18.3 CUBIC INCH CAPACITY) TP7152 — 25 4 – 1/ 2" US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 61 Weatherproof Outlet Covers WEATHERPROOF COVERS Weatherproof ONE & TWO GANG, SELF-CLOSING COVERS WITH GASKETS UL LISTED, ZINC DIE-CAST TP7199 TP7202 TP7206 – TP7209 TP7214 TP7220 TP7224 TP7228 TP7232 Cat. # Description TP7199 TP7202 TP7206 TP7207 TP7208 TP7209 TP7214 TP7218 TP7220 One Gang Vertical Duplex Cover One Gang – For Single Receptacle or Switch – 1.52" Dia. Opening One Gang – For Duplex Receptacle or Combination Switch One Gang – For Duplex Receptacle or Combination Switch One Gang – For Duplex Receptacle or Combination Switch One Gang – For Duplex Receptacle or Combination Switch One Gang Vertical – For Single Receptacle or Switch 1.62" Dia. Opening One Gang – For 20, 30 and 50 A Receptacles (2.125" Dia.) Two Gang – For Two Single Receptacles and/or Switches Two Gang – For One Single Receptacle or Switch and One Duplex Receptacle, Switch or Combination Device Two Gang – For Two Duplex Receptacles, Switches or Combination Device One Gang Stay Open – For Duplex Receptacles, Switches or Combination Devices, Non UL Listed One Gang Stay Open – For Duplex Receptacles, Switches or Combination Devices, Non UL Listed TP7224 TP7228 TP7232 TP7233 TP7218 Color Std. Unit Carton Wt. Lbs. Per 100 Gray Gray Natural Gray White Bronze Gray Gray Gray 50 25 50 50 50 50 25 25 10 61.1 42.0 38.0 38.0 38.0 38.0 61.1 55.6 66.7 Gray 10 62.0 Gray 10 61.1 Natural 50 38.0 Gray 50 38.0 CLOSURE PLUGS – ZINC DIE-CAST* Cat. # Description TP7940 TP7942 TP7944 1/ 2" 1/ 2" 3/ 4" Color Std. Unit Carton Wt. Lbs. Per 100 Gray Bronze Gray 100 100 50 1.5 1.5 2.1 *CSA certified 62 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Weatherproof Outlet Covers WEATHERPROOF COVERS ONE & TWO GANG SELF-CLOSING GFI COVERS WITH GASKETS UL LISTED, ZINC DIE-CAST TP7236 – TP7238 TP7240 – TP7242 TP7244 TP7248 TP7252 Description Color Std. Unit Carton Wt. Lbs. Per 100 TP7236 TP7237 TP7238 TP7240 TP7241 TP7242 TP7244 One Gang – For Horizontal GFI Devices One Gang – For Horizontal GFI Devices One Gang – For Horizontal GFI Devices One Gang – For Vertical GFI Devices One Gang – For Vertical GFI Devices One Gang – For Vertical GFI Devices Two Gang – For Vertical GFI Devices and One Single Switch or Receptacle Two Gang – For One Vertical GFI Device and One Duplex Receptacle, Switch or Combination Device Two Gang – For Two GFI Devices Gray White Bronze Gray White Bronze Gray 25 25 25 25 25 25 10 42 42 42 54 54 54 61.1 Gray 10 61.1 Gray 10 55.6 TP7248 TP7252 Weatherproof Cat. # WEATHERPROOF COVERS FOR ONE & TWO GANG BOXES "CONSTANT USE" DUPLEX/GFI COVER UL & CSA LISTED, POLYCARBONATE TP7490 TP7495 31/8" Deep 21/4" Deep Cat. # Description Color Std. Unit Carton Wt. Lbs. Per 100 TP7490 TP7495 One Gang, Vertical Mtg. For Duplex or GFI Device (Inserts Included) One or Two Gang, Vertical or Horizontal Mtg. For One Duplex or GFI Device (Inserts Included) Clear Clear 6 6 41.7 75 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 63 Weatherproof Outlet Covers WEATHERPROOF COVERS ONE & TWO GANG TOGGLE SWITCH COVERS WITH GASKETS STAMPED ALUMINUM UL LISTED Weatherproof TP7280 TP7268 5/ 8" Thick Cat. # Description TP7260 TP7268 TP7272 TP7276 TP7280 One Gang With 15A 125V Single Pole Switch Two Gang Two Gang With 2 – 15A 125V Single Pole Switch Two Gang With 2 – 15A 125V 3-Way Switch One Gang Extended Switch Cover – (for use with Standard Switch) Std. Unit Carton Wt. Lbs. Per 100 50 10 10 10 50 27.8 16.7 33.3 33.3 34.1 ALUMINUM BLANK BOX WEATHERPROOF COVERS WITH GASKETS UL LISTED FOR WET LOCATIONS TP7292 – TP7294 TP7296 – TP7298 Cat. # Description Color Std. Unit Carton Wt. Lbs. Per 100 TP7292 TP7293 TP7294 TP7296 TP7297 TP7298 One Gang One Gang One Gang Two Gang Two Gang Two Gang Gray White Bronze Gray White Bronze 100 100 100 50 50 50 8.3 8.3 8.3 12.5 12.5 12.5 64 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Weatherproof Outlet Covers ROUND AND RECTANGULAR WEATHERPROOF COVERS WITH GASKETS, ZINC DIE-CAST, UL LISTED FOR WET LOCATIONS TP7300 – 7302 TP7308 – 7310 Description TP7300 TP7301 TP7302 TP7308* TP7309* TP7310* TP7312 TP7313 TP7314 TP7316 TP7317 TP7318 TP7320 TP7321 TP7322 TP7158 TP7159 TP7160 41/ 2" Round 41/ 2" Round 41/ 2" Round 41/ 2" Round 41/ 2" Round 41/ 2" Round Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Rectangular Blank Round Blank Round Blank Round No. of Outlet Holes 1 1 1 3 3 3 1 1 1 2 2 2 3 3 3 – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" – 1/ 2" — — — TP7316 – 7318 TP7320 – 7322 TP7158 – 7160 Color Std. Unit Carton Wt. Lbs. Per 100 Gray White Bronze Gray White Bronze Gray White Bronze Gray White Bronze Gray White Bronze Gray White Bronze 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 50 50 50 20.8 20.8 20.8 33.3 33.3 33.3 33.3 33.3 33.3 33.3 33.3 33.3 33.3 33.3 33.3 20.8 20.8 20.8 Weatherproof Cat. # TP7312 – 7314 *Comes with closure plug US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 65 Weatherproof Lampholders WEATHERPROOF LAMPHOLDERS AND ACCESSORIES ZINC DIE-CAST CONSTRUCTION, UP TO 150 WATTS, WITH LAMP GASKET, UL LISTED Weatherproof TP7162 – TP7165 TP7166 Cat. # Description TP7162 TP7163 TP7164 TP7165 TP7166 TP7170 TP7176 Universal Par Lampholder Universal Par Lampholder Universal Par Lampholder Universal Par Lampholder Universal Par Lampholder With External Gasket External Gasket Only Clamp-On Guard TP7176 Color Std. Unit Carton Wt. Lbs. Per 100 Natural Gray White Bronze Gray — — 36 36 36 36 36 100 24 47.2 47.2 47.2 47.2 50 3 50 WEATHERPROOF LAMPHOLDERS AND ACCESSORIES ZINC DIE-CAST CONSTRUCTION, UP TO 150 WATTS, WITH LAMP GASKET, UL LISTED TP7178 TP7186 TP7188 (Aluminum) Cat. # Description Color Std. Unit Carton Wt. Lbs. Per 100 TP7178 TP7186 TP7188 Par Lampholder With Reflector Portable Par Lampholder With 6' Cord 21/ 2" Outside Diameter Pole Fitter with 1/ 2" Male Thread Gray Gray Gray 6 12 24 166.7 100 50 WEATHERPROOF LAMPHOLDER COMBINATIONS ZINC DIE-CAST CONSTRUCTION, WITH GASKETS, UL LISTED TP7330 – TP7332 Cat. # Description Color Std. Unit Carton Wt. Lbs. Per 100 TP7330 TP7331 TP7332 2 Par Lampholders and 3-Hole Round Cover 2 Par Lampholders and 3-Hole Round Cover 2 Par Lampholders and 3-Hole Round Cover Gray White Bronze 10 10 10 137.5 137.5 137.5 66 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Weatherproof Outdoor HID Luminaires Luminarea™ Series Area Luminaires Cooper Crouse-Hinds Luminarea Luminaires are ideally suited for general and security lighting indoors or outdoors. Area luminaires are available in 2 sizes in 70 to 175 watt metal halide and 70 to 150 watt high pressure sodium. The bronze epoxy powder coated housing is designed for an extended, trouble-free life. The housing is gasketed for raintight (NEMA 3R) locations. The prismatic polycarbonate lens is vandal resistant for even light distribution. Typical applications include parking garages, storage areas, stairwells, corridors and lobbies. Key Features and Benefits: Materials and Finishes: • • • • • • • • • • • Housing – Die Cast Aluminum Lens – Polycarbonate Gasket – Silicone Hardware – Stainless Steel Weatherproof Durable die cast aluminum housing for long product life. Architectural bronze powder paint finish for corrosive enviroments. Stainless steel hardware. Internal white reflector for maximum light output. Vandal resistant polycarbonate lens. Side and top plugged threaded entries for easy field wiring. High power factor ballast in multi-tap (120, 208, 240, 277 volt) or tritap (120, 277, 347 volt) configurations. • Two housing sizes insure maximum utilization of space. • Available in 70 to 175 watt metal halide or high pressure sodium versions. Ratings: • 70 to 175 watt metal halide and high pressure sodium • Multi-tap (120, 208, 240, 277 volts) or Tri-tap (120, 277, 347 volts) • 480V For accessories & dimensions, see pages 67–71 Certifications and Compliances: • UL1598 • UL and cUL listed • NEMA 3R raintight Cat. # Description High Pressure Sodium 70 120/208/240/277 70 120/277/347 100 120/208/240/277 100 120/277/347 150 120/208/240/277 150 120/277/347 Watts Voltage Lamp Base Ballast WLPG70HPS/MT WLPG70HPS/TT WLPG100HPS/MT WLPG100HPS/TT WLPG150HPS/MT WLPG150HPS/TT 8" × 8" Housing 8" × 8" Housing 12" × 12" Housing 12" × 12" Housing 12" × 12" Housing 12" × 12" Housing Medium Medium Medium Medium Medium Medium HPF HPF HPF HPF HPF HPF Metal Halide 70 120/208/240/277 70 120/277/347 100 120/208/240/277 100 120/277/347 175 120/208/240/277 175 120/277/347 WLPG70MH/MT WLPG70MH/TT WLPG100MH/MT WLPG100MH/TT WLPG175MH/MT WLPG175MH/TT 8" × 8" Housing 8" × 8" Housing 12" × 12" Housing 12" × 12" Housing 12" × 12" Housing 12" × 12" Housing Medium Medium Medium Medium Medium Medium HPF HPF HPF HPF HPF CWA Lamp not included. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 67 Weatherproof Outdoor HID Luminaires Luminarea™ Series Area Luminaires Weatherproof Cooper Crouse-Hinds Luminarea floodlights are ideally suited for area and outdoor parking lot lighting. The floodlights are available in 3 housing sizes in 150 to 1000 watt metal halide or high pressure sodium. The bronze epoxy powder coated housing is designed for an extended, trouble-free life. The housing is gasketed for raintight (NEMA 3R) locations. Floodlights are available with an optional slip fitter or swivel bracket for mounting flexibility. Typical applications include parking lots, area lighting, street lighting, recreational lighting and security lighting. Key Features and Benefits: Materials and Finishes: • • • • • • • • • • • • Durable die cast aluminum housing for long product life. Bronze powder paint finish for corrosive enviroments. Stainless steel hardware. Hinged lens for easy access to wiring and lamp chamber. Polished aluminum reflector maximizes light output. Side, bottom & rear plugged threaded entries for easy wiring. 150W & 175W fixture includes adjustable mounting bracket. 250 to 1000 watt fixtures must be ordered with separate slipfitter or swivel bracket (see page 67). • Three housing sizes insure maximum utilization of space. • Available in 150 to 1000 watt metal halide or high pressure sodium versions. Housing – Die Cast Aluminum Lens – Tempered Glass Gasket – Silicone Hardware – Stainless Steel Ratings: • • • • 150 to 1000 watt metal halide and high pressure sodium. 250 and 400 watt metal halide available with pulse start. Multi-tap (120, 208, 240, 277 volts) or Tri-tap (120, 277, 347 volts) 480V For accessories & dimensions, see pages 67–71 Certifications and Compliances: • UL1598 • UL and cUL listed • NEMA 3R raintight Cat. # Description High Pressure Sodium 150 120/208/240/277 150 120/277/347 250 120/208/240/277 250 120/277/347 400 120/208/240/277 400 120/277/347 1000 120/208/240/277 1000 120/277/347 Watts Voltage Lamp Base Ballast WLFL150HPS/MT* WLFL150HPS/TT* WLFL250HPS/MT† WLFL250HPS/TT† WLFL400HPS/MT† WLFL400HPS/TT† WLFL1000HPS/MT‡ WLFL1000HPS/TT‡ Medium Housing Medium Housing 16" × 16" Housing 16" × 16" Housing 16" × 16" Housing 16" × 16" Housing 23" × 23" Housing 23" × 23" Housing Medium Medium Mogul Mogul Mogul Mogul Mogul Mogul HPF HPF CWA-HPF CWA CWA-HPF CWA CWA-HPF CWA Metal Halide 175 120/208/240/277 175 120/277/347 250 120/208/240/277 250 120/208/240/277 250 120/277/347 400 120/208/240/277 400 120/208/240/277 400 120/277/347 1000 120/208/240/277 1000 120/277/347 WLFL175MH/MT* WLFL175MH/TT* WLFL250MH/MT† WLFL250MH/MT S828† WLFL250MH/TT† WLFL400MH/MT† WLFL400MH/MT S828† WLFL400MH/TT† WLFL1000MH/MT‡ WLFL1000MH/TT‡ Medium Housing Medium Housing 16" × 16" Housing 16" × 16" Housing, Pulse Start 16" × 16" Housing 16" × 16" Housing 16" × 16" Housing, Pulse Start 16" × 16" Housing 23" × 23" Housing 23" × 23" Housing Medium Medium Mogul Mogul Mogul Mogul Mogul Mogul Mogul Mogul CWA CWA CWA-HPF Pulse CWA CWA-HPF Pulse CWA CWA-HPF CWA Lamp not included. *150W & 175W Floodlight – Comes with adjustable mounting bracket with 1/ 2" thread. †250W & 400W Floodlight – Must buy swivel bracket or slipfitter separately (see accessories, page 67). ‡1000W Floodlight – Must buy slipfitter separately (see accessories, page 67). 68 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Weatherproof Outdoor HID Luminaires Luminarea™ Series Area Luminaires Cooper Crouse-Hinds Luminarea wallpacks are ideally suited for security and perimeter lighting indoors and outdoors. Wallpacks are available in 3 housing sizes in 100 to 400 watt metal halide or high pressure sodium. The bronze epoxy powder coated housing is designed for an extended, trouble-free life. The housing is gasketed for raintight (NEMA 3R) locations. The prismatic glass lens is designed for optimal light distribution to minimize the total number of luminaires required. Typical applications include office buildings, stores, restaurants, warehouses, banks and parking garages. Materials and Finishes: • • • • • • • • • • • Durable die cast aluminum housing for long product life. Architectural bronze powder paint finish for corrosive environments. Stainless steel hardware. Hinged lens for easy access to wiring and lamp chamber. Glass prismatic lens provides superior light distribution. Top, side and rear plugged threaded entries for easy field wiring. High power factor ballast in multi-tap (120, 208, 240, 277 volt) or tritap (120, 277, 347 volt) configurations. • Three housing sizes insure maximum utilization of space. • Available in 100 to 400 watt metal halide or high pressure sodium versions. Weatherproof Key Features and Benefits: Housing – Die Cast Aluminum Lens – Tempered Glass Gasket – Silicone Hardware – Stainless Steel Ratings: • 100 to 400 watt metal halide and high pressure sodium. • Multi-tap (120, 208, 240, 277 volts) or Tri-tap (120, 277, 347 volts) • 480V For accessories & dimensions, see pages 67–71 Certifications and Compliances: • UL1598 • UL and cUL listed • NEMA 3R raintight Watts Voltage Cat. # Description Lamp Base Ballast High Pressure Sodium 100 120/208/240/277 100 120/277/347 150 120/208/240/277 150 120/277/347 250 120/208/240/277 250 120/277/347 400 120/208/240/277 400 120/277/347 WLWP100HPS/MT WLWP100HPS/TT WLWP150HPS/MT WLWP150HPS/TT WLWP250HPS/MT WLWP250HPS/TT WLWP400HPS/MT WLWP400HPS/TT Small Housing Small Housing Medium Housing Medium Housing Large Housing Large Housing Large Deep Housing Large Deep Housing Medium Medium Medium Medium Mogul Mogul Mogul Mogul HPF HPF HPF HPF CWA-HPF CWA CWA CWA Metal Halide 100 120/208/240/277 100 120/277/347 175 120/208/240/277 175 120/277/347 250 120/208/240/277 250 120/208/240/277 250 120/277/347 400 120/208/240/277 400 120/208/240/277 400 120/277/347 WLWP100MH/MT WLWP100MH/TT WLWP175MH/MT WLWP175MH/TT WLWP250MH/MT WLWP250MH/MT S828 WLWP250MH/TT WLWP400MH/MT WLWP400MH/MT S828 WLWP400MH/TT Small Housing Small Housing Medium Housing Medium Housing Large Housing Large Housing, Pulse Start Large Housing Large Deep Housing Large Deep Housing, Pulse Start Large Deep Housing Medium Medium Medium Medium Mogul Mogul Mogul Mogul Mogul Mogul HPF HPF CWA-HPF CWA CWA-HPF Pulse CWA CWA Pulse CWA Lamp not included. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 69 Weatherproof Outdoor HID Luminaires Luminarea™ Series Area Luminaires WALLPACKS Mounting Plate Wire Guards Weatherproof FLOODLIGHTS Swivel Bracket Cat. # Slipfitters Wire Guards Description Accessories for Wallpacks & Area Luminaires WLWPMP 1 Mounting Plate for 100W Wallpack & Area Luminaire WLWPWG 1 Wire Guard for 100W Wallpack WLWPWG 2 Wire Guard for 150/175W Wallpack WLWPWG 3 Wire Guard for 250 & 400W Wallpack Accessories for Floodlights WLFLSB 3 Swivel Bracket for 250 & 400W Floodlight WLFLSF 3 Slipfitter for 250 and 400W Floodlight WLFLSF 4 Slipfitter for 1000W Floodlight WLFLWG 3 Wire Guard for 250 & 400W Floodlight WLFLWG 4 Wire Guard for 1000W Floodlight WLFLGS 2 Glare Shield for 150/175W Medium Floodlight WLFLGS 3 Glare Shield for 250 & 400W Floodlight WLFLGS 4 Glare Shield for 1000W Floodlight 70 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Glare Shields Weatherproof Outdoor HID Luminaires Luminarea™ Series Area Luminaires Area Luminaires (Inches) Weight: 15lbs. 100W to 175W 12.25W × 8.5H × 12.25D Weatherproof 70W 8.75W × 7.5H × 8.75D Floodlight Luminaires (Inches) Weight: 15lbs. 150W & 175W 250W & 400W 1000W 9.0W × 6.75H × 5.75D 16.0W × 16.0H × 7.25D 23.0W × 23.0H × 10.25D Wallpack Luminaires (Inches) Weight: 15lbs. 100W 150W & 175W 250W 400W 8.5W × 9.375H × 7.0D 13.0W × 9H × 7.25D 18.0W × 9.0H × 9.75D 18.0W × 9.0H × 12.75D US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 71 Vapor Proof Lighting Incandescent VAPOR PROOF FIXTURES – GASKETED CORROSION RESISTANT DIE-CAST CONSTRUCTION, GLASS GLOBES, DIE-CAST GUARDS, UL LISTED Weatherproof TP7600, TP7601, TP7800, TP7801, TP7860 Cat. # TP7610, TP7611, TP7805 TP7620, TP7810 TP7621, TP7811 TP7630, TP7815 Hole Size Description 4" BOX MOUNTED TP7600 Clear Globe, Cast Guard TP7601 Clear Globe, Cast Guard TP7800 Clear Globe, Wire Guard TP7801 Clear Globe, Wire Guard TP7860 Fluorescent Clear Globe, Wire Guard TP7610 Clear Globe TP7611 Clear Globe TP7805 Clear Globe TP7660, TP7830 Std. Unit Carton Wt. Lbs. Per 100 100 100 200 200 13 100 100 200 1 1 1 1 1 1 1 1 325 324 516.7 516 413 258.3 258 283.3 1/ 2" 100 100 200 200 100 200 1 1 1 1 1 1 300 299 350 349 208.4 258.4 — — — — 100 200 100 200 1 1 1 1 275 333.3 216.7 180 3/ 4" 1/ 2" 3/ 4" 1/ 2" 1/ 2" 3/ 4" 1/ 2" 1/ 2" 3/ 4" 1/ 2" 3/ 4" 1/ 2" SURFACE MOUNT, FITS 3" and 4" ROUND BOXES TP7640 Clear Globe, Cast Guard TP7820 Clear Globe, Wire Guard TP7650 Clear Globe TP7825 Clear Globe TP7670, TP7835 TP7650, TP7825 Watts 1/ 2" PENDANT MOUNT TP7620 Clear Globe, Cast Guard TP7621 Clear Globe, Cast Guard TP7810 Clear Globe, Wire Guard TP7811 Clear Globe, Wire Guard TP7630 Clear Globe TP7815 Clear Globe TP7640, TP7820 TP7680, TP7840, TP7870 TP7690, TP7845 Watts Std. Unit Carton Wt. Lbs. Per 100 RIGHT ANGLE BRACKET FIXTURES TP7660 Clear Globe, Cast Guard TP7830 Clear Globe, Wire Guard TP7670 Clear Globe TP7835 Clear Globe 100 200 100 200 1 1 1 1 300 516.7 200 400 BOX MOUNTED TP7680 TP7840 TP7825 Clear Globe, Cast Guard Clear Globe, Wire Guard Clear Globe 100 200 200 1 1 1 350 560 450 FLUORESCENT TP7870 Clear Globe, Wire Guard 13 1 462 Cat. # 72 Description US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Vapor Proof Lighting Incandescent VAPOR PROOF COMPONENTS Pendant Ceiling Box Cap Ceiling Box Right Angle Right Angle/Box Wt. Lbs. Per 100 PENDANT CAP, PORCELAIN SOCKET GASKET AND SCREWS TP7496 100 Gray, 1/ 2" TP7497 100 Gray, 3/ 4" 200 TP7498 Gray, 1/ 2" TP7499 200 Gray, 3/ 4" 10 10 10 10 18 18 10 10 CEILING BOX CAP, SOCKET GASKET AND SCREWS TP7447 Gray TP7448 Gray 10 10 12 12 CEILING MOUNT BOX WITH GASKETS, PORCELAIN SOCKET AND SCREWS TP7450 100 Gray, 1/ 2" TP7478 100 Gray, 3/ 4" 200 TP7451 Gray, 1/ 2" 200 TP7478 Gray, 3/ 4" 10 10 10 10 19 19 19 19 RIGHT ANGLE BRACKET GASKET, SOCKET, SCREWS TP7445 Gray TP7446 Gray 10 6 21 12 1 1 1 1 3 3 1.5 1.5 Description Watts 100 200 100 200 RIGHT ANGLE BRACKET ATTACHED BOX, GASKET, SOCKET AND SCREWS TP7440 100 Gray, 1/ 2" TP7441 100 Gray, 3/ 4" TP7442 200 Gray, 1/ 2" 200 TP7443 Gray, 3/ 4" Weatherproof Std. Unit Carton Cat. # VAPOR PROOF FIXTURE ACCESSORIES TP7460 – TP7466 TP7468 – TP7472 Cat. # Description TP7460 TP7462 TP7463 TP7464 TP7466 TP7468 TP7469 TP7470 TP7471 TP7472 TP7474 TP7475 TP7476 TP7477 Glass Clear Globe, 130 °F Max Glass Amber Globe Glass Blue Globe Glass Green Globe Glass Clear Globe Lexan Clear Prismatic Lexan Blue Prismatic Lexan Red Prismatic Lexan Amber Prismatic Lexan White Bayonet Mount Die-Cast Guard Wire Guard Clamp-On Wire Guard Adapter Plate US: 1-866-764-5454 TP7474, TP7475 CAN: 1-800-265-0502 TP7476 TP7477 Watts Std. Unit Carton Wt. Lbs. Per 100 100 100 100 100 200 75 60 75 75 75 100 200 100 — 12 12 12 12 6 12 12 12 12 12 12 6 12 12 98 120 120 120 200 58.4 58.4 58.4 58.4 58.4 108.4 183.4 62.5 62.5 Copyright© 2007 Cooper Crouse-Hinds 73 Commercial Products Fixture Hangers Flexible Fixture Hangers Cooper Crouse-Hinds TPSFH & TPRFH flexible fixture hangers are used in commercial or light industrial applications where HID high bay and low bay lighting fixtures are used. Specific applications include storage facilities, shipping warehouses, retail and DIY facilities. Weatherproof Features and Benefits: • Suitable for use with 1/ 2" or 3/ 4" fixture conduit stems these hangers allow the conduit stem of the fixture (luminaire) to swing in any direction. Maximum swing angle is 26° from vertical max slope angles 221/ 2° • Available in two styles; one for attachment to round or octagonal steel boxes, the other for attachment to 4" square steel boxes. • Both styles are quickly and easily attached by two screws. • Hangers are drilled and tapped for use with 3/ 4" conduit stem as standard and come supplied with a 3/ 4" – 1/ 2" reducer for 1/ 2" conduit stem applications. Description Support Wt. (lbs) Cat. # For use with 4" Round or Octagon Boxes 50 TPRFH12 For use with 4" Square boxes 50 TPSFH12 Certifications and Compliances: • UL Listed – UL 1598 • CSA C22.2 No. 250 • Suitable for Damp Locations Standard Materials and Finishes: • Material: Sheet Steel • Finish: Zinc Chromate for corrosion resistance Swiv-L-Drop™ Canopy Fixture Hangers The Swiv-L-Drop Canopy hanger utilizes a patented spring design to provide vibration and shock protection for pendant mounted fixtures in both horizontal and vertical directions. Designed to fit 3" or 4" outlet boxes the Swiv-L-Drop is for use with 1/ 2" fixture conduit stems. The smooth, white canopy provides an aesthetically pleasing appearance and installs quickly and easily without the use of tools. Certifications and Compliances: Description • UL Listed – UL 1598 • Suitable for Dry Locations Swiv-L-Drop Canopy Hanger for use with 3" or 4" Outlet boxes for use with 1/ 2" Conduit Stems. 50* S 1 1/2 Standard Materials and Finishes: For use with 3/ 8" Conduit Stems. 50* S 1 3/8 • Material: Sheet Steel • Finish: Canopy – painted white *65 lbs. rated with a minimum 12–inch stem if fully supported by other than an outlet box. Support Wt. (lbs) Cat. # Sway Adapters The Sway Adapter installs quickly and easily to pendant mounted fixtures and compensates for shocks and motion due to movements, vibration, earthquakes or other sources by allowing for lateral movement up to 45 degrees. The Sway Adapter can be used independently or in conjunction with the Swiv-L-Drop hanger. The Sway Adapter is also finished in an aesthetically pleasing white painted finish and is designed for use with 1/ 2" conduit stems and has 3/ 8" male threads. Certifications and Compliances: Description Cat. # Sway adapter for use with 1/ 2" Conduit Stem (male thread is 3/ 8") SA 1W • UL Listed – UL 1598 • Suitable for Dry Locations Standard Materials and Finishes: • Material: Sheet Steel • Finish: sway adapter – painted white 74 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Photoelectric Lighting PHOTOELECTRIC LIGHTING CONTROLS TP7920 TP7924 – TP7925 Description TP7920 TP7924 TP7925 TP7927 TP7928 300W Photo Cell With Plate 120V 300W Swivel Photo Cell 120V 1200W Swivel Photo Cell 120V 300W Photo Cell 120V 1000W Photo Cell 208 – 277V Std. Unit Pkg. 10 10 10 10 10 Wt. Lbs. Per 100 50 8.3 8.3 8.3 8.3 Weatherproof Cat. # TP7927 – TP7928 CLOSURE PLUGS – ZINC DIE-CAST* Cat. # Description TP7940 TP7942 TP7944 1/ 2" 1/ 2" 3/ 4" Std. Unit Pkg. Color Wt. Lbs. Per 100 100 100 50 Gray Bronze Gray 1.5 1.5 2.1 *CSA Certified Dimensions In Inches: Single Gang Boxes Single Gang Deep Boxes Two Gang Boxes TP7010 – TP7071 TP7074 – TP7082 TP7086 – TP7122 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 75 Dimensional Data Dimensions Dimensions In Inches: 76 Single Gang Boxes Single Gang Deep Boxes Two Gang Boxes TP7010 – TP7071 TP7074 – TP7082 TP7086 – TP7122 Two Gang Deep Boxes Round Boxes Extension Rings and Flanged Boxes TP7126 – TP7142 TP7146 TP7120 Extension Rings and Flanged Boxes Single Gang, Duplex Receptacle Covers TP7173 – TP7174 TP7206 – TP7209 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Dimensional Data Dimensions In Inches: Two Gang, Single Receptacle Covers Single Gang, Duplex Receptacle Covers – Vertical Mount TP7202 TP7220 TP7199 Two Gang, Duplex Receptacle Covers Single Gang, GFCI Covers Horizontal Mount Single Gang, GFCI Covers Vertical Mount TP7228 TP7236 – TP7238 TP7240 – TP7242 Two Gang, GFCI Covers Blank Covers Blank Covers TP7248 TP7292 – TP7294 TP7296 – TP7298 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Dimensions Single Gang, Single Receptacle Covers – Vertical Mount 77 Dimensional Data Dimensions Dimensions In Inches: 78 Blank Covers Single Gang, Switch Covers Vertical Mount Lampholders TP7158 TP7256 TP7162 – TP7165 Hooded Lampholder Rectangular Lampholder Covers Round Lampholder Covers TP7178 TP7312 – TP7322 TP7300 – TP7310 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Dimensional Data VAPOR PROOF DIMENSIONS 200 WATT Cat. # TP7830 TP7840 TP7820 TP7810 TP7800 Length Overall Width Depth 121/ 2" 121/ 2" 71/ 2" 111/ 2" 103/ 4" 51/ 2" 51/ 2" 41/ 2" 51/ 2" 51/ 2" 61/ 8" 8" — — — 100 WATT DIMENSIONS Dimensions Vapor Proof Lighting Our Glass Globe Vapor proof fixtures comply with the latest U.L. requirements for standard 1598, for enclosed and gasketed incandescent fixtures. Suitable For Wet Locations Corrosion resistant, rugged die-cast construction castings. These lights are designed for indoor and outdoor industrial or commercial locations, gasketing allows their use in outdoor locations. Designed by our engineers for fast, easy on the job site installation. Cooper Crouse-Hinds Vapor proof series fixtures are perfect for permanent or temporary lighting. Screw on cast guards are supplied with allen head set screws locking it in place to help prevent vandalism. Unit features snap-in, snap-out, copper screw shell porcelain sockets with screws backed out. US: 1-866-764-5454 CAN: 1-800-265-0502 • Fixtures may be purchased complete or as components. • Fixtures constructed of Die-Cast Aluminum, Guards are Zinc DieCast. • Heat Resistant Clear Globe Available on 100 watt series. • Wire Guard Available. Clear glass is standard, colors are available, plastic (polycarbonate) globes which are virtually unbreakable are available in colors and are used as an alternative to glass globe-guard combinations (not recommended to exceed 60 watts). Copyright© 2007 Cooper Crouse-Hinds 79 C O M M E R C I A L OUTLET BOXES MYERS® HUBS F I T T I N G S EMT FITTINGS RIGID / IMC FITTINGS GROUND BUSHINGS Commercial Fittings & Accessories OUTLET BODIES LIQUIDTIGHT FITTINGS & A C C E S S O R I E S CORD AND CABLE CONNECTORS ARMORED CABLE AND FMC FITTINGS W-SERIES JUNCTION BOXES 80 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Myers® Hubs when installed in accordance with the NEC. Class I, Div. 2 Class II, Div. 1 and 2 Class III Applications: • Myers Scru-tite™ and Ground hub are used in the termination of electrical circuits through wall of the enclosure • Ideal for pharmaceutical, chemical and food processing, pulp/paper and nuclear industries. • Resistant to a variety of chemicals, including acetic, citric and salt water. • The O-ring is a special "Viton (75)" and has excellent chemical resistance. • Hub is provided with a stainless steel ground nut. Features: Vibration proof Grounding screw for added safety Captive o-ring gasket No welding Posi-Lok insulated throat (insuliner) Fit standard knockouts Easy installation Controlled thread lengths NPSL on male thread No sharp edges (along parting line) Hub Basic Scru-Tite® – NEMA 2, 3, 3R, 4, 4X and 12 Zinc UL File No. E-27258 Conduit Hubs • • • • • • • • • • Materials: • • • • • Nut: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316) Body: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316) Insuliner: Lexan O-Ring: Gasket Vi Ton Ground Screw: Steel Standard Finishes: • Aluminum: Natural • Zinc: Natural Optional Materials and Finishes: • Stainless: Natural • Zinc: Chrome-plate Certifications and Compliances: • NEC/CEC: Class I, Division 2 Class II, Division 1 & 2 Class III, Division 1 & 2 • UL Listed – UL Standard 514B • CSA Certified – Certified by UL to CSA standard C22.2 No. 18 • NEMA Type 2, 3, 3R, 4, 4X, 12 (std hub) • NEMA Type 2, 3, 3R, 4, 12 (ground hub) Cat. # ST ST ST ST ST ST ST ST ST ST ST ST ST 03† 1† 2† 3† 4† 5† 6† 7† 8 9 10 11* 12* 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Wt. Lbs. Per 100 25 25 25 25 10 10 10 5 2 2 2 1 1 12 20 32 40 60 70 90 200 250 300 350 600 800 Hub Basic Scru-Tite® – NEMA 2, 3, 3R, 4, 4X and 12 Aluminum UL File No. E-27258 STA STA STA STA STA STA STA STA STA STA STA STA CAN: 1-800-265-0502 3/ 8" Unit Qty. †Optional Nickel-Chrome Plate Finish. Add suffix -CP. See price list. *Not supplied with insulator. Cat. # US: 1-866-764-5454 Size 1 2 3 4 5 6 7 8 9 10 11 12 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 25 25 25 10 10 10 5 2 2 2 1 1 8 16 16 30 30 50 80 100 150 150 300 300 81 Class I, Div. 2 Class II, Div. 1 and 2 Class III Class I, ZONE 1, Ex e II Myers® Hubs Stainless Steel Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12 when installed in accordance with the NEC. Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12 Aluminum – Type 360 Stainless Steel – Type 316 UL File No. E-59509 Max. Copper Grd. Wire Size Conduit Hubs Cat. # SSTG SSTG SSTG SSTG SSTG SSTG SSTG SSTG SSTG SSTG Size 1/ 2" 1 2 3 4 5 6 7 8 9 10 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 10 10 10 5 5 5 2 2 2 2 20 30 43 55 73 95 — — — — Cat. # STAG STAG STAG STAG STAG STAG STAG STAG STAG STAG STAG STAG Size 1 2 3 4 5 6 7 8 9 10 11 12 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Wt. Lbs. Per 100 CSA UL 25 25 25 10 10 10 5 2 2 2 1 1 10 14 18 25 33 45 90 125 138 150 325 350 #8 #8 #8 #8 #6 #4 #2 1/0 2/0 2/0 3/0 3/0 #8 #8 #8 #8 #8 #8 #6 #6 #6 #4 #2 #1 Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12 Zinc Ground Hub Basic Scru-Tite® UL File No. E-59509 Zinc ATEX Approval with DEMKO 07 ATEX 0618172U II 2 G Ex e II UL File No. 187273 Class I, Zone 1, AEx e II Class I, Zone 1, Ex e II Max. Copper Grd. Wire Size Cat. # STG STG STG STG STG STG STG STG STG STG STG STG 1 2 3 4 5 6 7 8 9 10 11* 12* Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Wt. Lbs. Per 100 CSA UL 25 25 25 10 10 10 5 2 2 2 1 1 20 30 43 55 73 95 190 263 300 350 625 750 #8 #8 #8 #8 #6 #4 #2 1/0 2/0 2/0 2/0 3/0 #8 #8 #8 #8 #8 #8 #6 #6 #6 #4 #2 #1 Cat. # STGK STGK STGK STGK STGK STGK 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 10 10 10 5 5 5 20 30 43 55 73 95 3/ 4" 1" 11/ 4" 11/ 2" 2" *Not supplied with insulator 82 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds when installed in accordance with the NEC. Class I, Div. 2 Class II, Div. 1 and 2 Class III Class I, ZONE 1, Ex e II Myers® Hubs Stainless Steel – Type 316 Cap-Off ATEX Approval with DEMKO 07 ATEX 0618172U Zinc II 2 G Ex e II UL File No. E-187273 Class I, Zone 1, AEx e II Class I, Zone 1, Ex e II Cat. # Cat. # SSTGK SSTGK SSTGK SSTGK SSTGK SSTGK 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 10 10 10 5 5 5 20 30 43 55 73 95 3/ 4" 1 11/ 4" 11/ 2" 2 STC STC STC STC STC STC 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 25 25 25 10 10 10 13 20 28 40 53 70 3/ 4" 1" 11/ 4" 11/ 2" 2" Cap-Off Aluminum Ground Nut Zinc Cat. # STGN STGN STGN STGN STGN STGN Size 1/ 2" 1 2 3 4 5 6 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 CSA UL 25 25 25 10 10 10 6 10 13 15 23 30 #8 #8 #8 #8 #6 #4 #8 #8 #8 #8 #8 #8 Ground Nut Aluminum Max. Copper Grd. Wire Size Cat. # STAGN STAGN STAGN STAGN STAGN STAGN Size 1 2 3 4 5 6 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 CSA UL 25 25 25 10 10 10 3 5 6 8 10 13 #8 #8 #8 #8 #6 #4 #8 #8 #8 #8 #8 #8 STAC 1 STAC 2 STAC 3 Wt. Lbs. Per 100 25 25 25 6 8 12 1" Through-Bulkhead Fitting Zinc Cat. # STTB STTB STTB STTB STTB STTB STTB STTB STTB STTB 1 2 3 4 5 6 7 8 9 10 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 5 5 5 5 5 5 4 2 2 2 30 50 70 85 110 160 244 312 350 400 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Through-Bulkhead Fitting Aluminum STTBA STTBA STTBA STTBA STTBA STTBA STTBA STTBA CAN: 1-800-265-0502 Unit Qty. 1/ 2" 3/ 4" Cat. # US: 1-866-764-5454 Size Conduit Hubs Cat. # Max. Copper Grd. Wire Size 1 2 3 4 5 6 7 8 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 5 5 5 5 5 5 4 2 20 35 30 40 50 70 106 138 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" Copyright© 2007 Cooper Crouse-Hinds 83 when installed in accordance with the NEC. Class I, Div. 2 Class II, Div. 1 and 2 Class III Class I, ZONE 1, Ex e II Myers® Hubs Through-Bulkhead Fitting without nipples Metric To NPT Adapter Zinc Zinc Cat. # STTTB STTTB STTTB STTTB STTTB STTTB 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 5 5 5 5 5 5 35 60 75 85 120 170 3/ 4" 1" 11/ 4" 11/ 2" 2" Through–Bulkhead Fitting without nipples Aluminum Cat. # Size Unit Qty. Wt. Lbs. Per 100 M20 to 1/ 2" M25 to 3/ 4" M32 to 1" M40 to 11/ 4" M50 to 11/ 2" M63 to 2" 25 25 25 10 10 10 12 32 32 40 50 70 STM STM STM STM STM STM 1 2 3 4 5 6 Note: The Myers Metric to NPT hub adapter is used to convert a threaded metric entry to a NPT entry. The female thread is NPT and the male thread is metric. Metric To NPT Adapter Stainless Steel Conduit Hubs Cat. # STTTBA STTTBA STTTBA STTTBA STTTBA STTTBA 1 2 3 4 5 6 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 5 5 5 5 5 5 15 25 35 40 50 75 3/ 4" 1" 11/ 4" 11/ 2" 2" Non-Hazadous Drain Plug Stainless Steel UL File No. E-23223 Cat. # SSTC 1 SSTC 1CD Note: Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 25 10 13 13 1/ 2" Cat. # SSTM SSTM SSTM SSTM SSTM SSTM Size 1 2 3 4 5 6 1/ 2" M20 to M25 to 3/ 4" M32 to 1" M40 to 11/ 4" M50 to 11/ 2" M63 to 2" SSTC-1 is for knockouts and is supplied with a locknut and straight threads. SSTC-1CD is for threaded openings and is supplied without locknut and NPT threads. Not gasketed to allow for water drainage Non-Hazadous Drain Plug Aluminum UL File No. E-23223 Cat. # STAC 1ST STAC 1CD Note: 84 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 25 25 6 6 1/ 2" STAC-1ST is for knockouts and is supplied with a locknut and straight threads. STAC-1CD is for threaded openings and is supplied without locknut and NPT threads. Not gasketed to allow for water drainage US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 10 10 10 5 5 5 12 20 32 40 50 70 Myers® Hubs SCHEDULE OF DIMENSIONS PIPE SIZE E J "O" RING Cat. # A B C D MIN. MAX. ST 02 13/ 2 15/ 16 21/ 32 1/ 8 .350 .364 1/ 4 3/ 8 ST 03† 13/ 2 11/ 8 21/ 32 1/ 8 .468 1/ 2 ST 1† 111/ 32 17/ 16 13/ 16 3/ 16 .591 3/ 4 ST 2† 115/ 32 123/ 32 29/ 32 3/ 16 .783 1 ST 3† 121/ 32 2 11/ 32 1/ 4 .997 1.049 1 NPT 11/ 4 1.311 1.380 1/ 4 F G K H C.S. O.D. MIN. 60° 3/ 21 3/ 4 35/ 64 MAX. 9/ 16 15/ 16 43/ 64 11/ 16 NPT 1/ 4 .493 3/ 8 NPT 3/ 8 NPS 60° 3/ 32 .622 3/ 4 NPT 3/ 4 NPS 60° 1/ 8 11/ 2 55/ 64 7/ 8 .824 1/ 2 NPT 1/ 2 NPS 60° 1/ 8 17/ 16 11/ 16 11/ 8 1 NPS 60° 1/ 8 13/ 4 121/ 64 13/ 8 11/ 4 NPT 11/ 4 NPS 60° 1/ 8 21/ 8 143/ 64 13/ 4 11/ 2 11/ 2 21/ 2 159/ 64 2 21/ 2 NPS 111/ 16 23/ 8 11/ 32 1/ 4 ST 5† 111/ 16 23/ 4 11/ 32 1/ 4 1.529 1.610 60° 1/ 8 2 ST 6† 13/ 4 31/ 4 13/ 32 1/ 4 1.964 2.067 2 NPT 2 NPS 60° 1/ 8 3 225/ 64 21/ 2 ST 7 27/ 32 33/ 4 19/ 32 1/ 4 2.346 2.469 21/ 2 NPT 21/ 2 NPS 60° 1/ 8 31/ 2 257/ 64 3 3 ST 8 25/ 16 43/ 8 13/ 8 1/ 4 2.915 3.068 3 NPT 3 NPS 45° 1/ 8 41/ 8 333/ 64 35/ 8 31/ 2 ST 9 23/ 8 5 17/ 16 1/ 4 3.371 3.548 31/ 2 NPT 31/ 2 NPS 45° 1/ 8 45/ 8 41/ 64 41/ 8 4 ST 10 27/ 16 51/ 2 11/ 2 1/ 4 3.825 4.026 4 NPT 4 NPS 45° 1/ 8 51/ 8 433/ 64 45/ 8 5 ST 11* 215/ 16 67/ 8 2 1/ 4 4.795 5.047 5 NPT 5 NPS 45° 1/ 8 61/ 2 537/ 64 511/ 16 3 711/ 16 2 5/ 16 45° 1/ 8 71/ 4 641/ 64 63/ 4 6 ST 12* 5.762 6.065 NPT 6 NPT NPS 6 NPS Conduit Hubs ST 4† 11/ 2 *Not supplied with insulator. Options: Tolerance Description † Optional Nickel-Chrome Plate Finish. See price list. Suffix -CP Decimal Fractional Angular & Draft +/–.010 +/–1/16 +/–2° Cat. # Material ST STA SSTG Zinc Aluminium Stainless Dimensions and materials specified are subject to change without prior notice. PLAN VIEW SIDE VIEW "D" dimension indicated maximum panel thickness which hub will accommodate. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 85 Myers® Hubs SPACING CHART FOR MYERS HUBS Conduit Hubs CONDUIT OR PIPE SIZE HOLE SIZE. COND. SIZE. 1/ 4 9/ 16 1/ 4 11/ 16 11/ 16 3/ 8 15/ 32 11/ 4 7/ 8 1/ 2 15/ 16 113/ 32 19/ 16 11/ 8 3/ 4 17/ 16 117/ 32 111/ 16 113/ 16 13/ 8 1 19/ 32 111/ 16 127/ 32 131/ 32 21/ 8 13/ 4 11/ 4 125/ 32 17/ 8 21/ 32 25/ 32 25/ 16 21/ 2 2 3/ 8 1/ 2 3/ 4 1 11/4 11/2 2 21/2 3 31/2 11/ 2 131/ 32 21/ 16 27/ 32 211/ 32 21/ 2 211/ 16 27/ 8 21/ 2 2 27/ 32 25/ 16 215/ 32 219/ 32 23/ 4 215/ 16 31/ 8 33/ 8 3 21/ 2 215/ 32 29/ 16 223/ 32 227/ 32 3 33/ 16 33/ 8 35/ 8 37/ 8 35/ 8 3 225/ 32 27/ 8 31/ 32 35/ 32 35/ 16 31/ 2 311/ 16 35/ 16 43/ 16 41/ 2 41/ 8 31/ 2 33/ 32 33/ 16 311/ 32 315/ 32 35/ 8 313/ 16 4 41/ 4 41/ 2 413/ 16 51/ 8 45/ 8 4 5 6 4 311/ 32 37/ 16 319/ 32 323/ 32 37/ 8 41/ 16 41/ 4 41/ 2 43/ 4 51/ 16 53/ 8 53/ 4 511/ 16 5 41/ 32 41/ 8 49/ 32 413/ 32 49/ 16 43/ 4 415/ 16 53/ 16 57/ 16 53/ 4 61/ 16 63/ 16 71/ 8 63/ 4 6 413/ 32 41/ 2 421/ 32 425/ 32 415/ 16 51/ 8 55/ 16 59/ 16 513/ 16 61/ 8 67/ 16 611/ 16 73/ 8 73/ 4 19/ 32 11/ 16 27/ 32 31/ 32 11/ 8 15/ 16 11/ 2 13/ 4 2 25/ 16 25/ 8 27/ 8 39/ 16 315/ 16 Minimum space from center of pipe or conduit to nearest obstruction. 1. Dimensions in black squares are centers for conduits of same size. Example: How close may 3 conduits be spaced? Answer 41/ 2" 2.Dimensions in gray squares are for centers of conduits NOT of the same size. Example: What is the minimum spacing for 2" and 3/ 4" conduit? Read down column marked 3/ 4" to figure opposite 2" and find dimensions is 211/ 32". 3.Minimum spacing dimensions as shown will give approximately 1/ 8" clearance between locking nuts. 86 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Conduit Hubs Malleable Iron Conduit Hubs Applications: Iron Space Saver Conduit Hubs Applications: • Ideal for terminating electrical conduit through the walls of enclosures. • Designed for use indoors or outdoors with rigid conduit and IMC, specific applications include food processing plants, distilleries, breweries, sewage disposal plants, chemical plants, paper processing mills and refineries. • Ideal for terminating electrical conduit through the walls of enclosures. • Designed for use indoors or outdoors with rigid conduit and IMC, specific applications include food processing plants, distilleries, breweries, sewage disposal plants, chemical plants, paper processing mills and refineries. Features: Features: Certifications and Compliances: • • • • • • • Class I, Division 2 – NEC 501.4 (B) Class II, Divisions 1 & 2 – NEC 502.4 (A) (B) Class III, Divisions 1 & 2 – NEC 503.3 (A) (B) UL Listed – UL Standard 514B cUL Listed – Certified by UL to CSA Standard C22.2 No. 18 NEMA: FB-1 Suitable for wet locations Conduit Hubs • Male thread type • Tapered female thread for rigid conduit and IMC • Recessed O-ring gasket assures raintight and dust tight connections • Insulated throat provides smooth pulling surface • Locking screw on the nut doubles as a grounding screw for added safety • Complete size range from 1/ 2" to 6" • Hubs fit standard knockouts. No special tools required • Male thread is on the nut for space saving. • Quick and easy when installing rigid conduit nipple between two existing enclosures. • Insulated throat provides smooth pulling surface. • Furnished with SG sealing gasket. • Hub fits standard knockouts. No special tools required. Certifications and Compliances: • • • • • • • Class I, Division 2 - NEC 501.4(B). Class II, Divisions 1 & 2 - NEC 502.4(A)(B). Class III, Division 1 & 2 - NEC 503.3(A)(B). UL Listed - UL Standard 514B. cUL Listed - Certified by UL to CSA Standard C22.2 No. 18. NEMA: FB-1 Suitable for wet locations. Standard Materials & Finishes: • Material: Malleable Iron • Finish: Zinc Electroplate Dimensions In Inches: Cat. # MHUB1 MHUB2 MHUB3 MHUB4 MHUB5 MHUB6 MHUB7 MHUB8 MHUB9 MHUB10 MHUB11 MHUB12 Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 25 25 5 5 2 1 1 1 1 1 1 1 100 100 50 25 20 10 10 5 5 2 1 1 18 25 50 25 20 10 10 5 5 2 1 1 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Conduit Size Cat. # HUB1 HUB2 HUB3 HUB4 HUB5 HUB6 HUB7 HUB8 HUB9 HUB10 Note: US: 1-866-764-5454 CAN: 1-800-265-0502 1/ 2 3/ 4 1 11/ 4 11/ 2 2 21/ 2 3 31/ 2 4 Unit Qty. 25 10 5 5 2 1 1 1 1 1 Wt. Lbs. Per 100 18 25 50 25 20 10 10 5 5 2 a b 1 11/ 8 13/ 8 11/ 2 15/ 8 111/ 16 23/ 16 27/ 16 27/ 16 29/ 16 11/ 4 19/ 16 17/ 8 25/ 16 21/ 2 3 35/ 8 41/ 4 43/ 4 51/ 4 c 1 13/ 8 15/ 8 2 23/ 8 213/ 16 37/ 16 41/ 16 411/ 16 51/ 16 d x 1/ 8 9/ 64 5/ 32 1/ 4 3/ 16 9/ 32 1/ 4 7/ 16 1/ 4 7/ 16 1/ 4 7/ 16 1/ 4 7/ 16 1/ 4 7/ 16 5/ 16 3/ 4 5/ 16 11/ 8 Dimension "x" is maximum wall thickness of box that will meet the requirement for three full threads engagement of nipple and fitting body when box connector or rigid conduit hub is installed in a knockout or slip hole. Copyright© 2007 Cooper Crouse-Hinds 87 Commercial Products Fixture Hangers Flexible Fixture Hangers Fixture Hangers Cooper Crouse-Hinds TPSFH & TPRFH flexible fixture hangers are used in commercial or light industrial applications where HID high bay and low bay lighting fixtures are used. Specific applications include storage facilities, shipping warehouses, retail and DIY facilities. Features and Benefits: • Suitable for use with 1/ 2" or 3/ 4" fixture conduit stems these hangers allow the conduit stem of the fixture (luminaire) to swing in any direction. Maximum swing angle is 26° from vertical max slope angles 221/ 2° • Available in two styles; one for attachment to round or octagonal steel boxes, the other for attachment to 4" square steel boxes. • Both styles are quickly and easily attached by two screws. • Hangers are drilled and tapped for use with 3/ 4" conduit stem as standard and come supplied with a 3/ 4" – 1/ 2" reducer for 1/ 2" conduit stem applications. Description For use with 4" Round or Octagon Boxes For use with 4" Square boxes Support Wt. (lbs) Cat. # 50 50 TPRFH12 TPSFH12 Certifications and Compliances: • UL Listed - UL 1598 • CSA C22.2 No. 250 • Suitable for Damp Locations Standard Materials and Finishes: • Material: Sheet Steel • Finish: Zinc Chromate for corrosion resistance Swiv-L-Drop™ Canopy Fixture Hangers The Swiv-L-Drop Canopy hanger utilizes a patented spring design to provide vibration and shock protection for pendant mounted fixtures in both horizontal and vertical directions. Designed to fit 3" or 4" outlet boxes the Swiv-L-Drop is for use with 1/ 2" fixture conduit stems. The smooth, white canopy provides an aesthetically pleasing appearance and installs quickly and easily without the use of tools. Certifications and Compliances: Description • UL Listed - UL 1598 • Suitable for Dry Locations Standard Materials and Finishes: • Material: Sheet Steel • Finish: Canopy – painted white Support Wt. (lbs) Cat. # Swiv-L-Drop Canopy Hanger for use with 3" or 4" Outlet boxes for use with 1/ 2" Conduit Stems. 50* S 1 1/2 For use with 3/ 8" Conduit Stems. 50* S 1 3/8 *65 lbs. rated with a minimum 12–inch stem if fully supported by other than an outlet box. Sway Adapters The Sway Adapter installs quickly and easily to pendant mounted fixtures and compensates for shocks and motion due to movements, vibration, earthquakes or other sources by allowing for lateral movement up to 45 degrees. The Sway Adapter can be used independently or in conjunction with the Swiv-L-Drop hanger. The Sway Adapter is also finished in an aesthetically pleasing white painted finish and is designed for use with 1/ 2" conduit stems and has 3/ 8" male threads. Certifications and Compliances: Description Cat. # Sway adapter for use with 1/ 2" Conduit Stem (male thread is 3/ 8") SA 1W • UL Listed – UL 1598 • Suitable for Dry Locations Standard Materials and Finishes: • Material: Sheet Steel • Finish: Sway Adapter – painted white 88 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Thin Wall Conduit Fittings (For EMT Conduit) • • • • Raintight Compression Type Fittings Straight Connectors Couplings COMPRESSION TYPE FITTINGS – RAINTIGHT CONNECTORS Applications: Straight Connectors – Non-Insulated – Raintight UL File No. E-22132 • The Cooper Crouse-Hinds Raintight EMT connectors are used to join EMT conduit to a box or enclosure in Raintight environments. • The design prevents water seepage into conduit, box or enclosure. Features and Benefits: Certifications and Compliances: • • • • UL Listed cUL Listed Concrete Tight Raintight Size 650RT 651RT 652RT 653RT 654RT 655RT 656RT 657RT 658RT 659RT 1/ 2" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 25 10 10 5 2 1 1 1 250 125 100 50 50 25 10 5 5 5 11 17 23 41 50 67 177 234 280 360 Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 25 10 10 5 2 1 1 1 250 125 100 50 50 25 10 5 5 5 14 21 28 49 60 79 187 245 390 485 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Couplings – Raintight UL File No. E-22132 Cat. # Size 660RT 661RT 662RT 663RT 664RT 665RT 666RT 667RT 668RT 669RT 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Thinwall Fittings • All steel construction with zinc electroplate finish provides for durable corrosion resistance • Flat surface on Gland nut provides smooth, flat surface for easy wrenching • Distinct black gland nut provides quick raintight identification • Integral gasketed compression ring secures and seals for reliable installation • Interior shoulder conduit stop provides positive seating of conduit inside the body • Gasket on male threads of box connector seals installation for raintight connection between the box and the connector • Available in insulated and non-insulated versions to meet any customer preference • Angled teeth on locknut for secure bite into enclosure • Extruded locknut with shoulder provides more threads for more secure installation • Concrete tight • Standard material: Steel • Standard finish: Zinc plated Cat. # Straight Connectors – Insulated – Raintight UL File No. E-22132 Cat. # 1650RT 1651RT 1652RT 1653RT 1654RT 1655RT 1656RT 1657RT 1658RT 1659RT Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 25 10 10 5 2 1 1 1 250 125 100 50 50 25 10 5 5 5 11 17 23 41 50 67 177 234 330 360 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 89 Thin Wall Conduit Fittings (For EMT Conduit) • Compression Type Fittings • Straight Connectors • Couplings COMPRESSION TYPE FITTINGS – STEEL Applications: Straight Connectors – Non-Insulated UL File No. E-22132 Thinwall conduit fittings are used: • To join EMT to a box or enclosure • To couple two ends of EMT conduit Features: Compression Type • Unique raised bump design affords fast, positive locking of compression nuts • Male Hub Threads - NPSM • Steel Locknuts • Heavy Steel Walls • Standard Material: Steel • Standard Finish: Zinc Plated Concrete Tight Straight Connectors – Insulated UL File No. E-22132 Cat. # Size 650S 651S 652 653 654 655 656 657 658 659 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 50 25 25 10 10 5 2 1 1 1 9 16 25 43 54 76 190 300 280 360 Unit Qty. Wt. Lbs. Per 100 50 25 25 10 10 5 2 1 1 1 12 18 27 46 63 92 250 410 390 485 Couplings Thinwall Fittings UL File No. E-22132 Cat. # 1650 1651 1652 1653 1654 1655 1656 1657 1658 1659 90 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 50 25 25 10 10 5 2 1 1 1 11 16 25 43 54 76 190 300 330 360 US: 1-866-764-5454 CAN: 1-800-265-0502 Cat. # Size 660S 661S 662 663 664 665 666 667 668 669 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds Thin Wall Conduit Fittings (For EMT Conduit) • Compression Type Fittings • Set Screw Type Fittings • Combination Couplings SPACE-SAVER EMT SET-SCREW & COMPRESSION CONNECTORS - STEEL COMBINATION COUPLINGS – STEEL UL File No. E22132 UL File No. E-19189 Concrete Tight EMT (Compression) To Rigid (Threaded) Applications: • Use to join EMT conduit to box or enclosure Features: Cooper Crouse-Hinds Space Saver EMT Connector (on right) provides maximum useable space inside the box unlike a traditional connector with bushing. Traditional EMT connector protrudes inside box and creates the cumbersome and labor intensive need to clip the device mounting screw to install device. Cat. # 690S 691 692 Size 1/ 2" – 1/ 2" – 3/ 4" 1" – 1" 3/ 4" Unit Qty. Wt. Lbs. Per 100 25 20 10 9 13 19 Thinwall Fittings • Male threads on locknut allow for more room inside the box • Smooth pulling surface won’t strip cable – no bushing or insulated throat required • Angled teeth on locknut bite into enclosure, preventing loosening from vibration • Knurled wrenching surface for easy tightening • Zinc electroplated for corrosion resistance • Concrete tight when taped SET-SCREW CONNECTOR • Tri-head set screw may be installed using a slotted, Phillips, or Robertson head screwdriver COMPRESSION CONNECTOR • The split compression ring assures solid attachment to the conduit and good ground continuity • The hex surface on the compression nut provide for easy wrenching to quickly and easily tighten the nut The Space Saver EMT Connector's low profile design eliminates this cumbersome and labor intensive requirement. Certifications and Compliances: • UL Listed • CUL Listed Set Screw Type Connector Compression Connector Unit Qty. Wt. Lbs. Per 100 1" 100 50 25 8 12 12 Compression Connector 1/ 2" SSC50 3/ 4" SSC75 SSC100 1" 50 25 25 8 12 12 Cat. # Set Screw Connector SSBC50 SSBC75 SSBC100 Size 1/ 2" 3/ 4" US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 91 Thin Wall Conduit Fittings (For EMT Conduit) • Set Screw Type Fittings • Combination Couplings Couplings SET SCREW TYPE FITTINGS Features: • • • • • • • UL File No. E-22132 Pre-set & Staked Robertson Head Screws Male Hub Threads - NPSM Steel Locknuts Heavy Steel Walls Standard Material: Steel Standard Finish: Zinc Plated Concrete Tight when taped Straight Connectors – Insulated UL File No. E-22132 Thinwall Fittings Cat. # Size 1/ 2" 1450 1451 1452 1453* 1454* 1455* 1456*† 1457*† 1458*† 1459*† 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 50 25 20 10 10 5 2 1 1 1 9 14 23 46 50 78 130 140 180 225 Cat. # Size 460 461 462 463* 464* 465* 466*† 467*† 468*† 469*† 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 50 25 20 10 10 5 2 1 1 1 9 16 23 42 50 77 130 140 240 250 *Four Tightening Screws †UL and cUL Listed for EMT, IMC and Rigid Conduit COMBINATION COUPLINGS – STEEL Standard Materials: • Steel Standard Finishes: • Zinc plated EMT (Set Screw) to Rigid (Set Screw) UL File No. E-19819 *Two Tightening Screws †UL and cUL Listed for EMT, IMC and Rigid Conduit Straight Connectors – Non-Insulated UL File No. E-22132 Cat. # 420 421 422 Cat. # Size 450S 451 452 453* 454* 455* 456* 457* 458* 459* 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 50 25 20 10 10 5 2 1 1 1 9 15 23 46 50 77 130 140 180 225 Size 1/ 2" 3/ 4" 1" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 20 10 100 100 50 17 25 37 *Two Tightening Screw 92 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Thin Wall Conduit Fittings (For EMT Conduit) • • • • • Set Screw Type Fittings Combination Couplings Straight Connectors Couplings Offset Connectors SET SCREW TYPE FITTINGS – ZINC DIE CAST Features: Couplings UL File No. E-22132 • Tri-head Set Screw may be installed using a slottted, Phillips or Robertson head screwdriver • Concrete Tight when taped Standard Materials: Cat. # • Zinc 460DC 461DC 462DC 463DC* 464DC* 465DC* 466DC* 467DC* 468DC* 469DC* Standard Finishes: • Natural Straight Connectors – Insulated UL File No. E-22132 Size Unit Qty. Std Pkg. Wt. Lbs. Per 100 50 25 20 10 10 5 12 12 6 6 500 250 200 100 60 20 12 12 6 6 5 7 13 18 28 36 64 81 98 116 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" *Four Tightening Screws Cat. # Size 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Std Pkg. Wt. Lbs. Per 100 50 25 25 10 10 5 12 12 6 6 500 250 200 100 60 40 12 12 6 6 5 8 11 20 25 37 59 78 101 120 Offset Connectors – Non-Insulated UL File No. E-22132 Cat. # 2400 2401 2402 Size 1/ 2" 3/ 4" 1" Unit Qty. Wt. Lbs. Per 100 10 10 10 11 18 25 Thinwall Fittings 1/ 2" 1450DC 1451DC 1452DC 1453DC* 1454DC* 1455DC* 1456DC* 1457DC* 1458DC* 1459DC* Unit Qty. *Two Tightening Screws Straight Connectors – Non-Insulated UL File No. E-22132 Cat. # 450DC 451DC 452DC 453DC* 454DC* 455DC* 456DC* 457DC* 458DC* 459DC* Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std Pkg. Wt. Lbs. Per 100 50 25 25 10 10 5 12 12 6 6 500 250 200 100 60 40 12 12 6 6 5 7 11 21 25 36 58 77 98 117 *Two Tightening Screws US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 93 Thin Wall Conduit Fittings (For EMT Conduit) • • • • Compression Type Fittings Combination Couplings Straight Connectors Couplings COMPRESSION TYPE FITTINGS – ZINC DIE CAST Features: Couplings UL File No. E-22132 • The split compression ring assures solid attachment to the conduit and good ground continuity • The hex surfaces on the compression nut provide for easy wrenching to quickly and easily tighten the nut • Concrete tight Standard Materials: • Zinc Standard Finishes: • Natural Straight Connectors – Insulated UL File No. E-22132 Cat. # Size 660DC 661DC 662DC 663DC 664DC 665DC 666DC 667DC 668DC 669DC 1/ 2" Unit Qty. Std Pkg. Wt. Lbs. Per 100 50 25 15 10 10 5 12 12 6 6 500 250 150 100 50 20 12 12 6 6 11 16 22 40 48 64 124 144 190 228 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Thinwall Fittings COMBINATION COUPLINGS – ZINC DIE CAST Cat. # 1650DC 1651DC 1652DC 1653DC 1654DC 1655DC 1656DC 1657DC 1658DC 1659DC Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std Pkg. Wt. Lbs. Per 100 50 25 15 10 10 5 12 12 6 6 500 250 150 100 40 20 12 12 6 6 8 11 17 31 39 56 93 120 149 172 EMT (Set Screw) to Rigid (Set Screw) Concrete Tight UL File No. E-19189 Cat. # 2420 2421 Size 1/ 2" 3/ 4" – 1/ 2" – 3/ 4" Straight Connectors – Non-Insulated UL File No. E-22132 Cat. # Size 650DC 651DC 652DC 653DC 654DC 655DC 656DC 657DC 658DC 659DC 1/ 2" 94 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std Pkg. Wt. Lbs. Per 100 50 25 15 10 10 5 12 12 6 6 500 250 150 100 40 20 12 12 6 6 8 11 17 31 39 56 93 120 149 172 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 50 25 8 12 Thin Wall Conduit Fittings (For EMT Conduit) • • • • • Combination Couplings 90° Pulling Elbows Straps Clamps Clampbacks/Spacers COMBINATION COUPLINGS – ZINC DIE CAST Two Hole EMT (Set Screw) to Flexible Steel (Clamp) UL File No. E-184283 STRAPS – STEEL GALVANIZED UL File No. E-19189 Cat. # Size Unit Qty. 780DC 1/ 2"– 3/ 8" 50 Std. Pkg. Wt. Lbs. Per 100 500 8 Cat. # 90 DEGREE PULLING ELBOWS – ZINC DIE CAST Applications: • To connect EMT to form a 90° bend, or to connect EMT to box or enclosure • Removable cover and gasket facilitate wire pulling 1/ 2" 3/ 4" 1" 11/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Wt. Lbs. Per 100 250 150 100 50 50 25 25 25 25 10 1500 300 — — — — — — — — 2 3 5 8 13 14 19 23 93 108 Unit Qty. Std. Pkg. Wt. Lbs. Per 100 A B C D 20 15 6 3 200 150 60 30 17 24 54 80 1.77 2.13 3.18 3.26 1.02 1.28 1.54 1.91 .42 .43 .50 .63 .61 .77 .98 1.29 A = Length of cover, B = Width (not shown) Cat. # Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 516* 517* 518* 519* 21/ 2" 3" 31/ 2" 4" 5 2 2 2 30 12 12 12 104 120 150 220 Thinwall Fittings 850EB DC 875EB DC 8100EB DC 8125EB DC 3/ 4" Std. Pkg. UL File No. E-184283 UL File No. E-22132 Size 1/ 2" 1 2 3 4 5 6 9 10 11 12 Unit Qty. CLAMPS – MALLEABLE IRON EMT To Box Cat. # 497 497 497 497 497 497 496 496 496 496 Size *Also for use with Rigid/IMC Conduit EMT To EMT CLAMPBACKS/SPACERS – IRON Applications: UL File No. E-22132 • Provides space between conduit and mounting surface Standard Materials: • Malleable Iron Standard Finishes: Cat. # 850EE DC 875EE DC 8100EE DC 8125EE DC Size 1/ 2" 3/ 4" 1" 11/ 4" • Zinc plated Unit Qty. Std. Pkg. Wt. Lbs. Per 100 A B C D 20 15 6 3 200 150 60 30 15 22 52 80 1.77 2.13 3.18 3.26 1.02 1.28 1.54 1.91 .59 .80 .98 1.29 .93 1.18 1.53 1.91 A = Length of cover, B = Width (not shown) UL File No. E-184283 Cat. # Size CB1 CB2 CB3 CB4 CB5 CB6 CB7 CB8 CB9 CB10 CB11† CB12† 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 25 25 25 25 10 10 10 10 10 5 5 300 300 100 100 100 60 60 60 10 10 5 5 8 10 12 21 42 40 49 62 91 110 135 225 †Not UL Listed US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 95 Thin Wall Conduit Fittings (For EMT Conduit) • Clamps "Snap-On" • Nailing Straps • Bendsaver CLAMPS "SNAP-ON" – STEEL Applications: BENDSAVER CONDUIT STRAPS AND COUPLINGS Features: • To support EMT conduit to mounting surface Heavy Gauge UL File No. E-184283 Cat. # Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 100 100 50 25 25 25 25 10 10 500 500 500 250 100 25 25 25 10 10 5 6 6 13 17 20 64 71 120 130 1/ 2" 200 201 202 203 204 205 206* 207* 208* 209* 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" • Never offset bend 1/ 2" and 3/ 4" EMT conduit again when running EMT into a junction box. Stand-off design eliminates conduit bending and provides automatic alignment with electrical box knockouts. • Only one strap and one coupling are required per conduit run • Patented design eliminates conduit bending and allows for automatic alignment of EMT to box knockouts • Conduit straps are steel with zinc plating, couplings are zinc die cast Certifications and Compliances: • UL Listed • cUL Listed Specification Grade Steel Bendsaver Conduit Straps for EMT and Zinc Diecast Bendsaver Coupling Thinwall Fittings *Not UL LIsted NAILING STRAPS – CAST STEEL Standard Materials: Steel Bendsaver strap • Cast Steel Standard Finishes: • Zinc plated Support EMT, IMC and rigid conduit to mounting surface Conduit Sizes Cat. # EMT Rigid NS 1 NS 2 NS 3 1/ 2" 3/ 8" 1" 3/ 4" 3/ 4" 1/ 2" Unit Qty. Wt. Lbs. Per 100 100 100 100 2 2 3 Old way requires two straps, one coupling and two offset bends Zinc die cast Bendsaver coupling Cat. # Size Dimensions Cat. # A B C D NS 1 NS 2 NS 3 3/ 16 1 11/ 4 11/ 2 17/ 8 2 21/ 2 3/ 4 15/ 16 3/ 4 3/ 16 BSS50 BSS75 BSC50DC BSC75DC 11/ 8 1/ 2" 3/ 4" 1/ 2" 3/ 4" NAILING STRAPS – STAMPED STEEL Conduit Sizes Cat. # EMT Rigid NSS1 NSS2 NSS3 1/ 2" 3/ 8" 1" 3/ 4" 96 3/ 4" 1/ 2" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 100 100 1000 1000 1000 2 2 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds With the Bendsaver fittings, no offset bends are required and only one strap and one coupling! Unit Qty. Wt. Lbs. Per 100 100 50 100 50 8 9 9 14 Rigid/Intermediate Grade Conduit Fittings Concrete Tight • Type CPR Compression Fittings TYPE CPR COMPRESSION FITTINGS Features and Benefits: Straight Connectors – Insulated UL File No. E-19189 • UL Listed for use with IMC as well as metallic rigid conduit. • Unequalled versatility for the installer. • Unique gland ring design tightens up in fewer turns; provides outstanding pull-out strength; saves time and adds confidence. • Advanced, thoughtful design and premium materials team up for an installation you can be proud of. Cat. # Applications: Use type CPR compression fittings for: • Both IMC and metallic rigid conduit. • New work in poured concrete. • Maintenance, repairs and alterations. • Connections at panels and boxes. • New, altered or damaged stubups. • Applicable locations where field threading is impractical or undesirable. Certifications and Compliances: CPR11 CPR12 CPR13 CPR14 CPR15 CPR16 CPR17 CPR18 CPR19 CPR20 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 10 10 5 5 2 1 1 1 250 125 50 50 25 25 10 5 5 5 19 23 42 64 87 113 130 220 280 320 Straight Connectors – Non-Insulated • UL 514B Fittings for Conduit and Outlet Boxes UL File No. E-19189 Standard Materials: Bodies – malleable iron Compression nuts – iron Compression rings – stainless steel Locknuts – zinc plated steel Insuliners – glass-reinforced polypropylene Cat. # CPR1 CPR2 CPR3 CPR4 CPR5 CPR6 CPR7 CPR8 CPR9 CPR10 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 10 10 5 5 2 1 1 1 250 125 50 50 25 25 10 5 5 5 19 23 42 64 87 113 130 220 280 320 Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 20 10 5 5 2 2 1 1 1 125 100 50 25 25 10 10 5 5 5 26 38 59 85 124 162 220 320 380 440 Rigid Intermediate • • • • • Couplings UL File No. E-19189 Cat. # CPR21 CPR22 CPR23 CPR24 CPR25 CPR26 CPR27 CPR28 CPR29 CPR30 US: 1-866-764-5454 CAN: 1-800-265-0502 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds 97 Rigid/Intermediate Grade Conduit Fittings Concrete Tight • Set Screw Type Fittings SET SCREW TYPE FITTINGS SET SCREW TYPE FITTINGS Straight Connectors – Insulated Couplings UL File No. E-19189 UL File No. E-19189 Cat. # 150S 151 152 153 154 155* 1456*† 1457*† 1458*† 1459*† 160I*†§ 161I*†§ Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 5 10 5 2 2 1 1 1 1 1 200 100 50 50 25 10 10 5 5 1 1 1 16 27 40 50 76 110 210 282 380 400 850 1100 Rigid Intermediate *Two Tightening Screws †Malleable Iron §Not CSA Certified Cat. # 160 161 162 163 164 165* 466*† 467*† 468*† 469*† 170C*†§ 171C*†§ Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 20 5 10 5 2 2 1 1 1 1 1 100 100 50 50 25 10 10 5 1 1 1 1 27 40 52 70 104 160 300 400 500 600 1500 1800 *Four Tightening Screws †Malleable Iron §Not CSA Certified Notes: 1456 – 1459, 456 – 459 & 466 – 469 are dual listed for EMT, Rigid, and IMC conduit. Straight Connectors – Non-Insulated UL File No. E-19189 Cat. # 150P 151P 152P 153P 154P 155P* 456* 457* 458* 459* 160P*†§ 161P*†§ Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 5 10 5 2 2 1 1 1 1 1 200 100 50 50 25 10 10 5 5 1 1 1 16 26 40 50 76 110 210 281 380 400 850 1100 *Two Tightening Screws †Malleable Iron §Not CSA Certified 98 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Rigid/Intermediate Grade Conduit Fittings Concrete Tight Raintight (SSR Series) • Set Screw Type Fittings • Combination Couplings SET SCREW TYPE FITTINGS Straight Connectors – Insulated U. S. Patent #3951436 Applications: Cat. # Rainboot™ connectors and couplings are used with rigid conduit for IMC, steel or aluminum. Outdoors or indoors. Use Rainboot fittings for: • Conduit systems expansion and alterations. • Maintenance and repair operations. • New, altered or damaged stubups. • Connections at panels and boxes. • Embedment in concrete. • Installations in tight quarters: near corners, walls, ceilings, overhangs, obstacles or adjacent raceways. • Situations where threading equipment or heavy pipe wrenches are impractical. • Conduit systems in NEC wet locations. SSR11 SSR12 SSR13 SSR14 SSR15 SSR16 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Wt. Lbs. Per 100 20 20 20 5 5 4 20 30 40 64 85 97 Straight Connectors – Non-Insulated Cat. # Size • The only line of rigid/IMC threadless fittings suitable for raintight applications. • The only alternative to field threading in NEC wet locations. • May be installed in any position. • Tough and durable, long lasting, trouble free installations. • Requires only a 3/ 8" wrench for installation. • Full line – 1/ 2" through 2". • Faster, easier method to install raintight rigid/IMC raceway systems. SSR1 SSR2 SSR3 SSR4 SSR5 SSR6* 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 20 20 20 5 5 4 21 23 40 64 85 96 Rigid Intermediate Features and Benefits: Standard Materials: Unit Qty. *Two Tightening Screws For sealing at enclosure, use Type SG sealing gaskets (see page 125). Couplings • Bodies Connectors – 1/ 2" – 2" steel Couplings – 1/ 2" – 2" steel • Boots – injection molded PVC attached with special epoxy. • Setscrews hardened steel coated with special sealing resin compound. Cat. # Size 1/ 2" SSR21 SSR22 SSR23 SSR24 SSR25 SSR26† Certifications and Compliances: • UL 514B – Fittings for cable and conduit 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 20 20 5 5 4 4 31 45 64 86 116 165 †Four Tightening Screws COMBINATION COUPLINGS – STEEL Concrete Tight EMT (Compression) To Rigid (Threaded) UL File No. E-19189 Cat. # 690S 691 692 US: 1-866-764-5454 CAN: 1-800-265-0502 Size 1/ 2" – 1/ 2" – 3/ 4" 1" – 1" 3/ 4" Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 25 20 10 9 13 19 99 • Combination Couplings • Fitting Locknuts • Grounding Locknuts Rigid/Intermediate Grade Conduit Fittings COMBINATION COUPLINGS FITTING LOCKNUTS Combination Couplings – Zinc Plated Steel Concrete Tight Steel EMT (Set Screw) To Rigid (Set Screw) UL File No. E-19189 Cat. # 420 421 422 Size 1/ 2" – 1/ 2" 3/ 4" – 3/ 4" 1" – 1" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 20 10 100 100 50 17 25 37 Combination Couplings – Malleable Iron Flexible Steel (Squeeze Type) To Rigid (Threaded) Cat. # Rigid Intermediate 65 66 67 68 Size 1/ 2" – 3/ 4" – 1" – 11/ 4" – 1/ 2" 3/ 4" 1" 11/ 4" Unit Qty. Wt. Lbs. Per 100 10 10 5 5 17 22 31 31 Cat. # Size 1/ 2" 11X 12X 13X 14X 15X 16X 17X 18X 19X 20X 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 500 100 50 100 50 50 25 20 10 10 2500 1000 500 500 250 250 100 100 50 50 1 1 3 3 4 4 10 15 18 22 GROUNDING LOCKNUTS Applications: • For use with bushing to bond 1/ 2" to 4" rigid conduit to boxes, cabinets or other enclosures, only where a locknut is exposed. Steel Combination Couplings – Zinc Die Cast UL File No. E-6225 Concrete Tight EMT (Set Screw) To Rigid (Set Screw) UL File No. E-19189 Cat. # 2420 2421 100 Size 1/ 2" – 1/ 2" 3/ 4" – 3/ 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 500 250 8 12 US: 1-866-764-5454 CAN: 1-800-265-0502 Cat. # GL GL GL GL GL GL GL GL GL GL 11 12 13 14 15 16 17 18 19 20 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 50 50 50 50 25 20 10 10 5 1000 500 500 250 250 100 100 50 50 25 2 3 4 6 7 9 28 38 48 52 Copyright© 2007 Cooper Crouse-Hinds • Conduit Locknuts • Insulated Throat Bushings • Non-Insulated Throat brushings Rigid/Intermediate Grade Conduit Fittings CONDUIT LOCKNUTS THROAT BUSHINGS 3/ 8" Malleable Iron Threaded 105°C Rated Plastic Throat Liner – 2" Steel, 21/2" – 6" Malleable Iron UL File No. E-19189 UL File No. E-19189 Cat. # Size 3/ 8" 10 11 12 13 14 15 16 17 18 19 20 22 23 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 100 100 50 100 50 50 20 10 10 5 2 1 2500 2500 1000 500 500 250 250 100 50 50 25 2 1 1 1 2 3 4 5 7 10 15 18 22 79 166 Insulated Cat. # Size 1031 1032 1033 1034 1035 1036 1037 1038 1039 1040 1041* 1042* 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Wt. Lbs. Per 100 100 100 50 50 10 20 10 10 5 5 1 1 3 4 7 15 19 22 44 54 72 95 100 127 *Not UL Listed Aluminum 11 12 13 14 15 16 17 18 19 20 Size 1/ 2" SA SA SA SA SA SA SA SA SA SA 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 100 100 50 100 50 50 20 10 10 5 1 1 1 2 2 3 9 13 16 52 Zinc Die Cast Cat. # Size 11DC 12DC 13DC 14DC 15DC 16DC 17DC 18DC 19DC 20DC 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 400 250 100 60 50 30 20 15 10 10 4000 2500 1000 600 500 300 200 150 100 100 1 1 2 3 5 8 10 15 16 19 US: 1-866-764-5454 CAN: 1-800-265-0502 Rigid Intermediate Cat. # Non-Insulated Cat. # Size 1/ 2" 1031NI 1032NI 1033NI 1034NI 1035NI 1036NI 1037NI 1038NI 1039NI 1040NI 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 100 100 50 50 10 20 10 10 5 5 3 4 7 15 19 22 44 54 72 95 Set Screw Type – Threadless 105°C Rated Plastic Throat Liner UL File No. E-19189 Cat. # Size S1031 S1032 S1033 S1034 S1035 S1036 S1037 S1038 S1039 S1040 S1041 S1042 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 100 100 50 50 10 20 10 10 5 5 1 1 3 4 7 15 19 22 44 54 72 95 100 127 101 Rigid/Intermediate Grade Conduit Fittings • • • • Insulated Throat Grounding Bushings Threaded Copper or Aluminum Ground Lug 105°C Rated & 150°C Rated INSULATED THROAT GROUNDING BUSHINGS Applications: Aluminum Lug – For Copper Or Aluminum Grounding Conductors – Threaded 105°C Rated Plastic Throat Liner UL File No. E-6225 • For use on threaded rigid/IMC conduit to provide a means of grounding conduit through an insulated bushing Malleable Iron-105°C Rated Plastic Throat Liner Copper Lug – For Copper Grounding Conductors – Threaded UL File No. E-6225 Trade Size Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 5 9 12 GLL4 GLL4 10 GLL5 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 19 23 24 GLL5 10 GLL6 GLL6 10 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 28 26 32 GLL7 GLL7 30 GLL7 250 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 53 60 67 GLL8 GLL8 30 GLL8 250 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 70 72 76 GLL9 GLL9 250 GLL10 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 100 100 110 GLL10 250 GLL11 GLL11 250 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 120 140 143 GLL12 GLL12 250 6" 6" #3/0 – #6 250MCM – #6 1 1 160 163 Cat. # GLL1 GLL2 GLL3 Trade Size Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 8 12 14 GLL4 10C GLL4C GLL5 10C 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 19 30 21 GLL5C GLL6C GLL6 10C 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 32 29 40 GLL7C GLL7 30C GLL7 250C 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 65 88 97 GLL8C GLL8 30C GLL8 250C 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 77 100 109 GLL9C GLL9 250C GLL10C 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 125 134 145 GLL10 250C GLL11C GLL11 250C 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 154 165 174 GLL12C GLL12 250C 6" 6" #3/0 – #6 250MCM – #6 1 1 195 204 Cat. # Rigid Intermediate GLL1C GLL2C GLL3C 3/ 4" Zinc Die Cast – 150°C Rated Plastic Throat Liner Aluminum Lug – for Copper or Aluminum Grounding Conductors UL File No. E-6225 Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 GLL1 DC GLL2 DC GLL3 DC 1/ 2" 1" 50 40 25 500 400 250 3 4 5 GLL4 DC GLL5 DC GLL6 DC 11/ 4" 11/ 2" 2" 25 25 10 250 250 100 9 10 14 GLL7 DC GLL8 DC GLL9 DC GLL10 DC 21/ 2" 3" 31/ 2" 4" 5 5 4 4 50 50 40 40 25 33 38 44 Cat. # 102 US: 1-866-764-5454 CAN: 1-800-265-0502 3/ 4" 3/ 4" Copyright© 2007 Cooper Crouse-Hinds Rigid/Intermediate Grade Conduit Fittings • • • • Insulated Throat Grounding Bushings Threadless Copper or Aluminum Ground Lug 105°C Rated Aluminum Lug – For Copper Or Aluminum Grounding Conductors – Threadless – Set Screw Type 105°C Rated Plastic Throat Liner INSULATED THROAT GROUNDING BUSHINGS Applications: UL File No. E-6225 • For use on threaded rigid/IMC conduit to provide a means of grounding conduit through an insulated bushing Copper Lug – For Copper Grounding Conductors – Threadless – Set Screw Type 105°C Rated Plastic Throat Liner UL File No. E-6225 Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 5 9 12 GLS4 GLS4 10 GLS5 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 19 23 24 GLS5 10 GLS6 GLS6 10 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 28 26 32 GLS7 GLS7 30 GLS7 250 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 53 60 67 GLS8 GLS8 30 GLS8 250 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 70 72 76 GLS9 GLS9 250 GLS10 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 100 100 110 GLS10 250 GLS11 GLS11 250 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 120 140 143 GLS12 GLS12 250 6" 6" #3/0 – #6 250MCM – #6 1 1 160 163 GLS1 GLS2 GLS3 Trade Size Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 8 12 14 GLS4C GLS4 10C GLS5C 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 19 30 21 GLS5 10C GLS6C GLS6 10C 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 32 29 40 GLS 7C GLS7 30C GLS7 250C 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 65 88 97 GLS8C GLS8 30C GLS8 250C 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 77 100 109 GLS9C GLS9 250C GLS10C 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 125 134 145 GLS10 250C GLS11C GLS11 250C 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 154 165 174 GLS12C GLS12 250C 6" 6" #3/0 – #6 250MCM – #6 1 1 195 204 Cat. # GLS1C GLS2C GLS3C 3/ 4" US: 1-866-764-5454 CAN: 1-800-265-0502 3/ 4" Copyright© 2007 Cooper Crouse-Hinds Rigid Intermediate Trade Size Cat. # 103 • Insulating Bushings • Insulated Throat Bushings • Threaded and Threadless Rigid/Intermediate Grade Conduit Fittings INSULATING BUSHINGS Standard Materials: 150°C Rated Threadless Set Screw Type UL File No. E-19189 • Plastic UL File No. E-19189 Rated 105°C Cat. # Rated 150°C Cat. # 931 932 933 934 935 936 937 938 939 940 941 942 H H H H H H H H H H H H 931 932 933 934 935 936 937 938 939 940 941 942 Trade Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 50 50 50 50 25 25 10 10 5 5 5 5 1 1 2 3 3 4 8 10 11 11 40 42 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Cat. # Trade Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 100 100 50 50 10 20 10 10 5 5 1 1 6 7 10 13 15 21 42 51 65 80 100 128 HS1031 HS1032 HS1033 HS1034 HS1035 HS1036 HS1037 HS1038 HS1039 HS1040 HS1041 HS1042 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Rigid Intermediate 150°C Rated – Zinc Die Cast Threaded UL File No. E-19189 INSULATED THROAT BUSHINGS Features: • Plastic liner will not chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Standard Materials: • Body – Malleable Iron • Insuliner – ULTEM1000 rated at 150°C Cat. # H1031DC H1032DC H1033DC H1034DC H1035DC H1036DC H1037DC H1038DC H1039DC H1040DC Standard Finishes: • Body – Zinc Plated 150°C Rated Threaded UL File No. E-19189 Cat. # H1031 H1032 H1033 H1034 H1035 H1036 H1037 H1038 H1039 H1040 H1041 H1042 104 Trade Size Unit Qty. Wt. Lbs. per 100 1/ 2" 100 100 50 50 10 20 10 10 5 5 1 1 6 8 11 14 17 24 51 62 85 104 130 167 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" US: 1-866-764-5454 CAN: 1-800-265-0502 Trade Size Unit Qty. Std. Pkg. Wt. Lbs. per 100 1/ 2" 100 100 50 50 20 10 10 5 5 2 1000 1000 500 100 100 50 25 25 25 20 2 3 5 7 9 11 27 33 39 46 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds Rigid/Intermediate Grade Conduit Fittings • Insulated Throat Grounding Bushings • Threaded Malleable Iron – 150°C Rated INSULATED THROAT GROUNDING BUSHINGS Features: Aluminum Lug – For Copper Or Aluminum Grounding Conductors – Threaded UL File No. E-6225 • Resilient plastic liner, resists corrosion, chemicals and temperature extremes • Insuliner – ULTEM1000 rated at 150°C • 1 Set screw provided with each fitting locks bushing in any desired position • External stainless steel hardware as standard Standard Finishes: • Zinc Plated Copper Lug – For Copper Grounding Conductors – Threaded UL File No. E-6225 Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 12 14 17 HGLL4C HGLL4 10C HGLL5C 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 20 32 23 HGLL5 10C HGLL 6C HGLL6 10C 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 35 30 42 HGLL7C HGLL7 30C HGLL7 250C 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 69 92 101 HGLL8C HGLL8 30C HGLL8 250C 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 80 103 112 HGLL9C HGLL9 250C HGLL10C 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 126 135 145 HGLL10 250C HGLL 11C HGLL11 250C 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 155 171 180 HGLL 12C HGLL 12 250C 6" 6" #3/0 – #6 250MCM – #6 1 1 210 317 3/ 4" Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 9 11 14 HGLL 4 HGLL4 10 HGLL 5 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 17 24 20 HGLL5 10 HGLL 6 HGLL6 10 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 24 27 31 HGLL 7 HGLL7 30 HGLL7 250 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 58 67 70 HGLL 8 HGLL8 30 HGLL8 250 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 69 78 81 HGLL 9 HGLL9 250 HGLL 10 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 101 104 120 HGLL10 250 HGLL 11 HGLL 11 250 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 123 145 150 HGLL 12 HGLL 12 250 6" 6" #3/0 – #6 250MCM – #6 1 1 185 186 US: 1-866-764-5454 CAN: 1-800-265-0502 3/ 4" Copyright© 2007 Cooper Crouse-Hinds Rigid Intermediate Trade Size Cat. # Lug Size HGLL 1 HGLL 2 HGLL 3 Malleable Iron – 150°C Rated HGLL1C HGLL2C HGLL3C Trade Size Cat. # 105 Rigid/Intermediate Grade Conduit Fittings • Insulated Throat Grounding Bushings • Threadless INSULATED THROAT GROUNDING BUSHINGS Features: Malleable Iron – 150°C Rated Set Screw Type – Aluminum Lug – For Copper Or Aluminum Grounding Conductors – Threadless UL File No. E-6225 • Resilient plastic liner resists corossion, chemicals and temperature extremes • Insuliner – ULTEM1000 rated at 150°C • 2 Set-screws provided with each fitting, locks bushings in any desired position Standard Finishes: Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 9 10 13 HGLS4 HGLS4 10 HGLS5 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 16 20 18 HGLS5 10 HGLS6 HGLS6 10 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 22 24 28 HGLS7 HGLS7 30 HGLS7 250 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 50 58 60 HGLS8 HGLS8 30 HGLS8 250 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 58 67 70 HGLS9 HGLS9 250 HGLS10 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 80 85 90 HGLS10 250 HGLS11 HGLS11 250 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 100 115 120 HGLS12 HGLS12 250 6" 6" #3/0 – #6 250MCM – #6 1 1 145 150 Cat. # Malleable Iron – 150°C Rated HGLS1 HGLS2 HGLS3 Set Screw Type – Copper Lug – For Copper Grounding Conductors – Threadless UL File No. E-6225 Trade Size Lug Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 1" #4 – #14 #4 – #14 #4 – #14 50 50 50 12 13 16 HGLS4C HGLS4 10C HGLS5C 11/ 4" 11/ 4" 11/ 2" #4 – #14 #1/0 – #8 #4 – #14 25 25 10 19 31 21 HGLS5 10C HGLS6C HGLS6 10C 11/ 2" 2" 2" #1/0 – #8 #4 – #14 #1/0 – #8 10 10 10 33 27 39 HGLS7C HGLS7 30C HGLS7 250C 21/ 2" 21/ 2" 21/ 2" #1/0 – #8 #3/0 – #6 250MCM – #6 10 10 10 60 83 92 HGLS8C HGLS8 30C HGLS8 250C 3" 3" 3" #1/0 – #8 #3/0 – #6 250MCM – #6 5 5 5 70 92 100 HGLS9C HGLS9 250C HGLS10C 31/ 2" 31/ 2" 4" #3/0 – #6 250MCM – #6 #3/0 – #6 1 1 1 105 115 100 HGLS10 250C HGLS11C HGLS11 250C 4" 5" 5" 250MCM – #6 #3/0 – #6 250MCM – #6 1 1 1 130 140 150 HGLS12C HGLS12 250C 6" 6" #3/0 – #6 250MCM – #6 1 1 170 180 Cat. # Rigid Intermediate Trade Size • Body – Zinc Plated HGLS1C HGLS2C HGLS3C 106 3/ 4" US: 1-866-764-5454 CAN: 1-800-265-0502 3/ 4" Copyright© 2007 Cooper Crouse-Hinds • Three Piece Conduit Couplings • Conduit Bushed Nipples Rigid/Intermediate Grade Conduit Fittings THREE PIECE CONDUIT COUPLINGS Applications: CONDUIT BUSHED NIPPLES Applications: • Used to join two lengths of threaded conduit. Couples conduit when conduit cannot be turned. • Used thru knockout to connect box to conduit coupling. • Used with a locknut to connect two boxes side by side or back to back. • Used with a locknut to connect fixture housing to continuous runs. Standard Materials: • Heavy duty casting Standard Finishes: Malleable Iron • Zinc Plated Non-Insulated Threaded NPSM for rigid conduit and IMC UL File No. E-19189 Malleable Iron (Concrete Tight) UL File No. E-19189 Cat. # Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Std. Pkg. Wt. Lbs. Per 100 25 25 10 5 5 5 2 1 1 1 1 1 150 100 60 30 30 30 12 5 5 1 1 1 23 35 60 91 167 215 430 463 655 800 1200 2100 †Not UL Listed 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Wt. Lbs. Per 100 50 25 10 10 10 10 5 5 1 1 1 1 3 8 13 19 30 37 68 92 130 200 350 425 Unit Qty. Wt. Lbs. Per 100 50 25 10 10 10 10 5 5 1 1 1 1 3 4 11 19 30 37 72 96 113 187 350 450 Rigid Intermediate Cat. # 190M 191 192 193 194 195 196 197 198 199 188† 189† Unit Qty. 50* 51 52 53 54 55 56 57 58 59 60† 61† Size *Steel †Not UL Listed Insulated UL File No. E-19189 Cat. # Size 1050* 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 1061 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" *Steel US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 107 • Conduit Bushed Nipples • 90° Pull Elbows • Offset Conduit Nipples Rigid/Intermediate Grade Conduit Fittings CONDUIT BUSHED NIPPLES – ZINC DIE CAST Non-Insulated UL File No. E-19189 Cat. # 50D 51D 52D 53D 54D 55D 56D 57D 58D 59D Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" • For connecting threaded rigid or IMC to form a 90° bend, or for connecting rigid or IMC to box or enclosure • Removable cover and gasket facilitate wire pulling Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Standard Materials: 100 50 25 10 25 10 10 10 10 5 1000 500 100 100 100 50 30 — — — 4 5 10 11 20 30 40 49 68 70 Gasketed – Liquidtight Rigid to Box Rigid Intermediate 90 DEGREE PULL ELBOWS – MALLEABLE IRON Features: • • • • • • • 90 DEGREE PULL ELBOWS – ZINC DIE CAST Applications: Raintight Furnished with Neoprene gasketed steel cover Furnished with Steel lock nut Furnished with Stamped Steel cover Threaded for rigid conduit and IMC For outdoor use Standard Finish: Zinc plated • Body — zinc • Gasket — neoprene • Cover — aluminum UL File No. E-19189 Cat. # Unit Qty. Std. Pkg. Wt. Lbs. per 100 1" 11/ 4" 20 15 6 3 200 150 60 30 17 25 53 80 Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 20 15 6 3 200 150 60 30 15 23 50 80 Size 1/ 2" 850RB DC 875RB DC 8100RB DC 8125RB DC 3/ 4" Rigid to Rigid UL File No. E-19189 Gasketed – Liquidtight Male To Female UL File No. E-19189 Cat. # 1/ 2" 850RR DC 875RR DC 8100RR DC 8125RR DC Cat. # 810 811 812 813 814 815 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 20 10 5 2 2 1 34 56 88 92 200 344 3/ 4" 1" 11/ 4" OFFSET CONDUIT NIPPLES – MALLEABLE IRON Features: • Threaded NPSM for rigid conduit and IMC • Standard Finish: Zinc Plated • USE: To offset the axis of raceways 3/ 4 of an inch Female To Female UL File No. E-19189 Cat. # Cat. # 820 821 822 823 824 825 108 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 20 10 5 2 2 1 36 49 94 140 200 344 US: 1-866-764-5454 CAN: 1-800-265-0502 300 301 302 303 Size 1/ 2" 3/ 4" 1" 11/ 4" Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 25 25 10 10 24 34 49 54 • • • • Rigid/Intermediate Grade Conduit Fittings Offset Conduit Nipples Knockout Snap-In Blanks Push Plugs Bushing Pennies OFFSET CONDUIT NIPPLES – ZINC DIE CAST PUSH PLUGS – PLASTIC* UL File No. E-19189 Cat. # 300DC 301DC 302DC 303DC 304DC 305DC Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 10 10 10 5 5 2 200 200 200 200 200 200 9 15 21 33 40 65 KNOCKOUT SNAP-IN BLANKS – STEEL Cat. # PPC PPC PPC PPC PPC PPC PPC PPC PPC PPC Size 1/ 2" 50 75 100 125 150 200 250 300 350 400 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 100 100 50 50 25 25 100 100 50 50 1 1 1 1 1 1 2 3 6 8 *Temperature Rating: 180° – 200°F Tensile Strength: 600 – 2300 PSI Cat. # Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Wt. Lbs. Per 100 100 100 50 50 50 20 2 2 2 3 5 7 BUSHING PENNIES – STEEL Applications: • A penny under a bushing will seal the end of conduit during construction. Cat. # 90 91 92 93 94 95 96 97 98 99 US: 1-866-764-5454 CAN: 1-800-265-0502 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 100 100 100 50 50 50 50 50 50 50 1 1 1 1 2 3 5 7 10 14 Rigid Intermediate 335 336 337 338 339 340 Unit Qty. 109 • Knockout Reducing Washers • Nailing Straps Rigid/Intermediate Grade Conduit Fittings KNOCKOUT REDUCING WASHERS – STEEL NAILING STRAPS – CAST STEEL Standard Materials: • Cast Steel Standard Finishes: • Zinc plated Rigid Intermediate Cat. # Size Std. Pkg. Wt. Lbs. Per 100 100 100 100 2500 100 100 1 2 2 342 343 344 3/ 4" 345 346 347 11/ 4" – 11/ 4" – 3/ 4" 11/ 4" – 1" 100 100 100 100 100 100 3 2 2 348 349 350S 11/ 2" – 1/ 2" 11/ 2" – 3/ 4" 11/ 2 – 1" 50 50 50 50 50 50 5 4 4 351 352 353 11/ 2 – 11/ 4" 2" – 1/ 2" 2" – 3/ 4 50 50 50 50 50 50 3 7 7 354 355 356 2" – 1" 2" – 11/ 4" 2" – 11/ 2" 50 50 50 50 50 50 6 5 3 360 361 362 21/ 2" – 1/ 2" 21/ 2" – 3/ 4" 21/ 2" – 1" 25 25 25 250 250 250 7 7 7 363 364 365 21/ 2" – 11/ 4" 21/ 2" – 11/ 2 21/ 2" – 2" 25 25 25 250 250 250 7 7 7 366 367 368 3" – 1" 3" – 11/ 4" 3" – 11/ 2" 25 25 25 250 250 250 14 14 14 369 370 S 371 3" – 2" 3" – 21/ 2" 3" – 11/ 2" 25 25 25 250 250 100 14 14 25 372 373 374 31/ 2" – 2" 31/ 2" – 21/ 2" 31/ 2" – 3" 25 25 25 100 100 100 25 25 25 375 376 377 378 4" – 2" 4" – 21/ 2" 4" – 3" 4" – 31/ 2" 25 25 25 25 100 100 100 100 35 35 35 35 110 – 1/ 2" 1" – 1/ 2" 1" – 3/ 4" Unit Qty. 1/ 2" US: 1-866-764-5454 CAN: 1-800-265-0502 Support rigid conduit and IMC to mounting surface Conduit Sizes Cat. # EMT Rigid NS 1 NS 2 NS 3 1/ 2" 3/ 8" 1" 3/ 4" 3/ 4" 1/ 2" Unit Qty. Wt. Lbs. Per 100 100 100 100 2 2 3 Dimensions In Inches: Cat. # A NS 1 NS 2 NS 3 3/ 16 3/ 4 3/ 16 B C D 1 11/ 4 11/ 2 17/ 8 3/ 4 2 21/ 2 15/ 16 11/ 8 NAILING STRAPS – STAMPED STEEL Conduit Sizes Cat. # EMT Rigid NSS1 NSS2 NSS3 1/ 2" 3/ 8" 1" 3/ 4" 3/ 4" 1/ 2" Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 100 100 1000 1000 1000 2 2 3 • Conduit Clamps Rigid/Intermediate Grade Conduit Fittings CLAMPS – MALLEABLE IRON Applications: STRAPS – STEEL GALVANIZED Applications: • To support rigid conduit and IMC to mounting surface • Used to secure rigid conduit or IMC to mounting surface UL File No. E-184283 Two Hole UL File No. E-184283 Cat. # 510 511 512 513 514 515 516* 517* 518* 519* 520† 521† Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 50 50 25 20 10 5 2 2 2 1 1 600 300 300 100 120 60 30 12 12 12 5 5 6 8 13 20 30 64 104 120 150 220 380 690 *Also for use with Thinwall (EMT) Conduit †Not UL Listed • To provide space between conduit and mounting surface 496 496 496 496 496 496 496 496 496 496 496 Size 3/ 8" 2 3 4 5 6 7 8 9 10 11 12 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 250 150 100 50 50 50 25 25 25 25 10 2 2 3 7 8 10 15 19 23 93 108 Rigid Intermediate CLAMPBACKS/SPACERS – MALLEABLE IRON Applications: Cat. # CLAMPS "SNAP-ON" – STEEL Applications: • To support rigid conduit and IMC to mounting surface Heavy Gauge UL File No. E-184283 UL File No. E-184283 Cat. # Size CB1 CB2 CB3 CB4 CB5 CB6 CB7 CB8 CB9 CB10 CB11† CB12† 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 25 25 25 25 10 10 10 10 10 5 5 300 300 100 100 100 60 60 60 10 10 5 5 8 10 12 21 42 40 49 62 91 110 135 225 Cat. # 410* 411* 412* 413* 414 415 206* 207* 208* 209* Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 50 50 50 25 25 25 25 10 10 500 500 250 250 100 25 25 25 10 10 5 6 11 13 20 22 64 71 120 130 *CSA Certified †Not UL Listed US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 111 • Conduit Clamps Rigid/Intermediate Grade Conduit Fittings CABLE AND CONDUIT HANGERS – STEEL With Bolt CONDUIT CLAMPS Applications: • Right Angle – to attach the conduit run at a 90° angle to a beam or structural member • Paralled Type – to attach the conduit run parallel to a beam or structural member Conduit Size EMT Cat. # 1/ 2" Rigid Intermediate 0B 1B 2B 2 1/2 B 3 B 4 B 5 B 6 B 7 B 8 B 9 B 3/ 4" Conduit Sizes Rigid 3/ 8" 1" 11/ 4" 11/ 2" — 2" 21/ 2" 3" 31/ 2" 4" & 1/ 2" 3/ 4" 1" — 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4 Right Angle Type – Electrogalvanized – Iron Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 100 100 100 100 100 50 50 25 10 10 400 400 600 — — — — — — — — 6 6 8 10 11 16 23 29 31 38 38 BEAM CLAMPS/INSULATOR SUPPORTS – MALLEABLE IRON Standard Finishes: Cat. # RAC50HD RAC75HD RAC100HD RAC125HD RAC150HD RAC200HD RAC250HD RAC300HD RAC350HD RAC400HD Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Load Rating Lbs Std. Pkg. Wt. Lbs. Per 100 30 50 60 75 80 100 125 165 200 330 50 50 50 25 25 25 10 10 10 10 37 40 42 49 54 71 95 107 120 131 • Zinc Plated Parallel Type – Electrogalvanized – Iron UL File No. E-184283 Base Cat. # Size 528 529 530 531 532 533 534 Jaw Max. Wt. Open Support 3/ 4" 5/ 8" 1" 1" 11/ 2" 2" 21/ 2" 3/ 4" 3/ 4" 5/ 8" 3/ 4" 3/ 4" 7/ 8" 7/ 8" 230 230 230 230 290 330 800 Tapped Holes Unit Qty. Std. Pkg. Wt. Lbs. Per 100 10 – 24 – 20 10 – 24 1/ 4" – 20 5/ 16" – 18 3/ 8" – 16 1/ 2" – 13 25 25 25 25 50 25 25 100 100 100 100 50 — — 14 13 23 24 47 81 155 1/ 4" Beam Clamps/Insulator Supports – Steel Cat. # Base Size Jaw Opening 529 S 3/ 4" 5/ 8" 112 Tapped Holes 1/ 4" – 20 Unit Qty. Wt. Lbs. Per 100 50 13 US: 1-866-764-5454 CAN: 1-800-265-0502 Cat. # PARC50HD PARC75HD PARC100HD PARC125HD PARC150HD PARC200HD PARC250HD PARC300HD PARC350HD PARC400HD Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds Load Rating Lbs Std. Pkg. Wt. Lbs. Per 100 30 50 60 75 80 100 125 165 200 330 50 50 50 25 25 25 25 10 10 10 50 53 60 70 82 132 192 194 216 232 • Conduit Clamps • Conduit Reducers Rigid/Intermediate Grade Conduit Fittings CONDUIT REDUCERS – STEEL/FERALOY® CONDUIT CLAMPS Applications: • Edge Type – to attach the conduit run at a 90° angle to a thin beam or structural member Edge Type – Electrogalvanized – Iron Cat. # Cat. # ETC50HD ETC75HD ETC100HD ETC125HD ETC150HD ETC200HD ETC250HD ETC300HD Trade Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 50 50 50 25 25 25 25 10 63 69 82 95 108 121 153 214 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" JCC Series conduit beam clamps are: • Available in 1/ 2" to 4" sizes • Suitable for IMC, EMT and rigid conduit • Designed to exceed UL load requirements • Made from ductile iron with an electrogalvanized finish • Designed to support conduit on vertical or horizontal beams Conduit Beam Clamp – J Type – Iron UL File No. E-184283 Cat. # JCC1 JCC2 JCC34 JCC56 JCC78 JCC910 Size 1/ 2" 3/ 4" 1" & 11/ 4" 11/ 2" & 2" 21/ 2" & 3" 31/ 2" & 4" Max Weight Support Unit Qty. Wt. Lbs. Per 100 150 150 225 300 500 700 25 25 10 5 2 2 35 43 90 190 380 575 US: 1-866-764-5454 CAN: 1-800-265-0502 Unit Qty. Wt. Lbs. Per 100 251 252 253 3/ 4" – 1/ 2" 1" – 1/ 2" 11/ 4" – 1/ 2" 50 25 10 4 13 30 254 255 260 11/ 2" – 1/ 2 2" – 1/ 2" 1" – 3/ 4" 10 5 25 43 83 7 261 262 263 11/ 4" – 3/ 4" 11/ 2" – 3/ 4" 2" – 3/ 4" 10 10 5 23 40 79 268 269 270 S 11/ 4" – 1" 11/ 2" – 1" 2" – 1" 10 10 5 18 27 66 275 276 281 11/ 2" – 11/ 4" 2" – 11/ 4" 2" – 11/ 2" 10 5 5 13 24 27 282 283 285 21/ 2" – 1" 21/ 2" – 11/ 4" 21/ 2" – 2" 10 10 10 120 130 150 3" – 11/ 2" 3" – 2" 3" – 21/ 2" 5 2 5 210 160 120 291 292 293 31/ 2" – 2" 31/ 2" – 21/ 2" 31/ 2" – 3" 2 2 2 200 225 150 294 295 296 4" – 2" 4" – 21/ 2" 4" – 3" 2 2 2 270 270 260 297 298 299 4" – 31/ 2" 5" – 4" 6" – 5" 2 1 1 160 385 475 288 289 290M Copyright© 2007 Cooper Crouse-Hinds Rigid Intermediate Features: Size 113 Rigid/Intermediate Grade Conduit Fittings • Heavy-Duty Conduit U-Bolts with Hex Nuts • Plugs • Split Conduit Couplings PLUGS – CAST IRON SPLIT CONDUIT COUPLINGS Features: Recessed • Concrete Tight • Suitable for use in Class I, Division 2 Areas Cat. # PLG1M PLG2M PLG3M PLG4M PLG5M PLG6M PLG7M PLG8M PLG9M PLG10M Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. Wt. Lbs. Per 100 50 50 25 25 10 10 2 2 1 1 6 11 22 34 48 82 150 222 340 380 Cat. # TCC1 TCC2 TCC3 TCC4 TCC5 TCC6 TCC7 TCC8 TCC9 TCC10 TCC12 TCC14 Rigid Intermediate Square Head Cat. # PLG15M PLG25M PLG35M PLG45M PLG55M PLG65M PLG75M PLG85M PLG95M PLG105M Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Body – Ductile Iron Clamping Hardware – Electrogalvanized Steel Gasket-Neoprene Unit Qty. Wt. Lbs. Per 100 50 50 25 25 10 10 1 1 1 1 12 16 25 34 48 80 116 185 232 310 Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" HEAVY-DUTY CONDUIT U-BOLTS WITH HEX NUTS Electrogalvanized – Iron Cat. # UBM50HD UBM75HD UBM100HD UBM125HD UBM150HD UBM200HD UBM250HD UBM300HD UBM350HD UBM400HD 114 Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Thread Size 5/ 16" – 18 – 18 5/ 16" – 18 5/ 16" – 18 5/ 16" – 18 3/ 8" – 16 3/ 8" – 16 3/ 8" – 16 3/ 8" – 16 3/ 8" – 16 5/ 16" Unit Qty. Wt. Lbs. Per 100 200 200 100 50 50 50 25 25 20 20 12 14 17 19 21 28 37 42 46 51 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 10 10 10 5 5 5 2 2 1 1 1 1 39 45 68 82 116 111 283 323 395 506 944 1218 • Conduit Hubs Rigid/Intermediate Grade Conduit Fittings IRON SPACE SAVER CONDUIT HUBS Applications: MALLEABLE IRON CONDUIT HUBS Applications: • Ideal for terminating electrical conduit through the walls of enclosures. • Designed for use indoors or outdoors with rigid conduit and IMC, specific applications include food processing plants, distilleries, breweries, sewage disposal plants, chemical plants, paper processing mills and refineries. • Ideal for terminating electrical conduit through the walls of enclosures. • Designed for use indoors or outdoors with rigid conduit and IMC, specific applications include food processing plants, distilleries, breweries, sewage disposal plants, chemical plants, paper processing mills and refineries. Features: Features: Certifications and Compliances: • • • • • • • Class I, Division 2 – NEC 501.4 (B) Class II, Divisions 1 & 2 – NEC 502.4 (A) (B) Class III, Divisions 1 & 2 – NEC 503.3 (A) (B) UL Listed – UL Standard 514B cUL Listed – Certified by UL to CSA Standard C22.2 No. 18 NEMA: FB-1 Suitable for wet locations Certifications and Compliances: • • • • • • • Class I, Division 2 - NEC 501.4(B). Class II, Divisions 1 & 2 - NEC 502.4(A)(B). Class III, Division 1 & 2 - NEC 503.3(A)(B). UL Listed - UL Standard 514B. cUL Listed - Certified by UL to CSA Standard C22.2 No. 18. NEMA: FB-1 Suitable for wet locations. Rigid Intermediate • Male thread type • Tapered female thread for rigid conduit and IMC • Recessed O-ring gasket assures raintight and dust tight connections • Insulated throat provides smooth pulling surface • Locking screw on the nut doubles as a grounding screw for added safety • Complete size range from 1/ 2" to 6" • Hubs fit standard knockouts. No special tools required • Male thread is on the nut for space saving. • Quick and easy when installing rigid conduit nipple between two existing enclosures. • Insulated throat provides smooth pulling surface. • Furnished with SG sealing gasket. • Hub fits standard knockouts. No special tools required. Standard Materials & Finishes: • Material: Malleable Iron • Finish: Zinc Electroplate Dimensions In Inches: Cat. # MHUB1 MHUB2 MHUB3 MHUB4 MHUB5 MHUB6 MHUB7 MHUB8 MHUB9 MHUB10 MHUB11 MHUB12 Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 25 25 5 5 2 1 1 1 1 1 1 1 100 100 50 25 20 10 10 5 5 2 1 1 18 25 50 25 20 10 10 5 5 2 1 1 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" Cat. # HUB1 HUB2 HUB3 HUB4 HUB5 HUB6 HUB7 HUB8 HUB9 HUB10 Note: US: 1-866-764-5454 CAN: 1-800-265-0502 Conduit Size Unit Qty. Wt. Lbs. Per 100 a b c 1/ 2 25 10 5 5 2 1 1 1 1 1 18 25 50 25 20 10 10 5 5 2 1 11/ 8 13/ 8 11/ 2 15/ 8 111/ 16 23/ 16 27/ 16 27/ 16 29/ 16 11/ 4 19/ 16 17/ 8 25/ 16 21/ 2 3 35/ 8 41/ 4 43/ 4 51/ 4 1 13/ 8 15/ 8 2 23/ 8 213/ 16 37/ 16 41/ 16 411/ 16 51/ 16 3/ 4 1 11/ 4 11/ 2 2 21/ 2 3 31/ 2 4 d x 1/ 8 9/ 64 5/ 32 1/ 4 3/ 16 9/ 32 1/ 4 7/ 16 1/ 4 7/ 16 1/ 4 7/ 16 1/ 4 7/ 16 1/ 4 7/ 16 5/ 16 3/ 4 5/ 16 11/ 8 Dimension "x" is maximum wall thickness of box that will meet the requirement for three full threads engagement of nipple and fitting body when box connector or rigid conduit hub is installed in a knockout or slip hole. Copyright© 2007 Cooper Crouse-Hinds 115 • • • • Series 5 Combination Conduit Outlet Bodies For EMT and IMC or Rigid Conduit EMT CONDUIT OUTLET BODIES – CAST ALUMINUM† Combination Conduit Outlet Bodies Die Cast Aluminum Available in SnapPack™ Stainless Steel Cover Screws Type T UL File No. E-15022 Applications: Die cast aluminium Series 5 Conduit Bodies are used in conduit systems to: • Act as pull outlets for conductors being installed • Provide openings for making splices and taps in conductors • Act as mounting outlets for lighting fixtures and wiring devices • Connect conduit sections • Provide taps for branch conduit runs • Make 90 degree bends in conduit runs • Provide for access to conductors for maintenance and future system changes • EMT Conduit bodies are supplied with threaded hubs for use with IMC or Rigid conduit and set screws for use with EMT conduit Cat. # T15 T25 T35 T45 T55 T65 Trade Size MT MT MT MT MT MT Trade Size Outlet Bodies Cat. # C15 C25 C35 C45 C55 C65 MT MT MT MT MT MT 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 33.5 33.5 69.5 10 10 5 2 2 1 100 50 25 10 10 5 27 40 64 165 150 270 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 1/0 AWAG 3 # 4/0 AWG Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 33.1 33.1 67.0 10 10 5 2 2 1 100 50 25 10 10 5 27 40 64 165 150 270 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 1/0 AWAG 3 # 4/0 AWG 3/ 4" 1" 11/ 4" 11/ 2" 2" Type LB Cat. # Type C Unit Qty. 1/ 2" Standard Materials: • Copper Free Aluminum‡ Internal Vol. in Cu. In. LB15 MT LB25 MT LB35 MT LB45 MT LB55 MT LB65 MT LB75 MT* LB85 MT* LB95 MT* LB105 MT* Trade Size Internal Vol. in Cu. In. Unit Qty. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.0 32.3 33.8 71.2 71.2 183.5 304.9 308.0 10 10 5 2 2 1 1 1 1 1 27 40 56 132 175 240 450 460 800 900 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 2 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 400 MCM 3 # 400 MCM 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" *Fittings greater than 2" are set-screw only (not combination threaded & set-screw) Covers, Aluminum Type LL Trade Size Cat. # LL15 LL25 LL35 LL45 LL55 LL65 MT MT MT MT MT MT 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Cat. # Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 35.8 35.8 69.7 10 10 5 2 2 1 100 50 25 10 10 5 27 40 64 165 150 270 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 1/0 AWAG 3 # 4/0 AWG LR15 LR25 LR35 LR45 LR55 LR65 Trade Size 116 MT MT MT MT MT MT Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 50 50 50 50 25 10 5 250 250 250 50 25 10 5 5 6 20 25 25 78 140 3/ 4" 1" 11/ 4" – 11/ 2" 2" 21/ 2" – 3" 31/ 2" – 4" Gaskets, Neoprene Type LR Cat. # 150 250 350 450 650 850D 950D Conduit Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Cat. # Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 35.8 35.8 69.7 10 10 5 2 2 1 100 50 25 10 10 5 27 40 64 165 150 270 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 1/0 AWAG 3 # 4/0 AWG US: 1-866-764-5454 CAN: 1-800-265-0502 GASK015N GASK025N GASK035N GASK045N GASK065N GASK085N GASK095N Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 100 100 50 50 25 10 10 100 100 50 50 25 10 10 2 2 3 6 10 20 30 3/ 4" 1" 11/ 4" – 11/ 2" 2" 21/ 2" – 3" 31/ 2" – 4" †SnapPack™ EMT conduit bodies consisting of body, cover and gasket assembled and shipped together, change "-MT" to "-MTC" in catalog number i.e.: LB25-MTC ‡Percentage of copper in conduit bodies is 0.1% min and 0.25 % max Copyright© 2007 Cooper Crouse-Hinds • Rigid Conduit Outlet Bodies • Die Cast Aluminum • Available in SnapPack™† Series 5 Conduit Outlet Bodies For Rigid/IMC Conduit RIGID CONDUIT OUTLET BODIES – CAST ALUMINUM Standard Materials: Type T † • Copper Free Aluminum‡ Options: Cat. # Description †SnapPack™ pre-packaged body, cover and neoprene gasket ie. LB25-CGN Suffix CGN Type C † Cat. # C15 C25 C35 C45 C55 C65 C75 C85 C95* C105* Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 33.5 33.5 69.5 69.5 188.0 307.0 309.0 10 10 5 2 2 1 1 1 1 1 100 50 25 10 10 5 1 1 1 1 27 40 64 165 150 270 500 600 900 1000 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 2 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 400 MCM 3 # 400 MCM *Not UL Listed Cat. # LL15 LL25 LL35 LL45 LL55 LL65 LL75 LL85 LL95 LL105 Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 35.8 35.8 69.7 69.7 186.0 306.0 308.0 10 10 5 2 2 1 1 1 1 1 100 50 25 10 10 5 1 1 1 1 30 48 64 140 160 270 500 600 900 1000 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 1/0 AWAG 3 # 4/0 AWG 3 # 300 MCM 3 # 350 MCM 3 # 350 MCM 3 # 350 MCM Type LR † Cat. # LR15 LR25 LR35 LR45 LR55 LR65 LR75 LR85 LR95 LR105 Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 33.1 33.1 67.0 67.0 175.0 298.0 300.0 10 10 5 2 2 1 1 1 1 1 100 50 25 10 10 2 1 1 1 1 32 46 70 175 185 300 550 650 950 1050 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 2 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 400 MCM 3 # 400 MCM Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.25 7.3 12.0 32.3 33.8 71.2 71.2 183.5 304.9 308.0 10 10 5 2 2 1 1 1 1 1 100 50 25 10 10 5 1 1 1 1 27 40 56 132 175 240 450 460 800 900 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 2 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 4/0 AWG 3 # 400 MCM 3 # 400 MCM *Not UL Listed Type LB † Cat. # LB15 LB25 LB35 LB45 LB55 LB65 LB75 LB85 LB95 LB105 Trade Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Covers, Aluminum Cat. # 150 250 350 450 650 850D 950D Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 50 50 50 50 25 10 5 250 250 250 50 25 10 5 5 6 20 25 25 78 140 3/ 4" 1" 11/ 4" – 11/ 2" 2" 21/ 2" – 3" 31/ 2" – 4" Gaskets, Neoprene Internal Vol. in Cu. In. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Max. # of Conductors 4.35 7.3 12.2 35.8 35.8 69.7 69.7 186.0 306.0 308.0 10 10 5 2 2 1 1 1 1 1 100 50 25 10 10 5 1 1 1 1 26 48 64 140 160 260 500 600 900 1000 NA 3 # 6 AWG 3 # 4 AWG 3 # 2 AWG 3 # 1/0 AWAG 3 # 4/0 AWG 3 # 300 MCM 3 # 350 MCM 3 # 350 MCM 3 # 350 MCM US: 1-866-764-5454 CAN: 1-800-265-0502 Cat. # GASK015N GASK025N GASK035N GASK045N GASK065N GASK085N GASK095N Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 100 100 50 50 25 10 10 100 100 50 50 25 10 10 2 2 3 6 10 20 30 3/ 4" 1" 11/ 4" – 11/ 2" 2" 21/ 2" – 3" 31/ 2" – 4" ‡Percentage of copper in conduit bodies is 0.1% min and 0.25 % max Copyright© 2007 Cooper Crouse-Hinds 117 Outlet Bodies Type LL † T15 T25 T35 T45 T55 T65 T75 T85 T95* T105* Trade Size • Rigid and combination Rigid or IMC and EMT Conduit Outlet Bodies • Die Cast Aluminum Conduit Outlet Bodies Series 5 Dimensions Type LB Dimensions – Threaded & Set Screw Conduit Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" A B C D E F 111/ 32" 135/ 64" 13/ 4" 235/ 64" 219/ 32" 313/ 64" 41/ 2" 415/ 32" 539/ 64" 539/ 64" 157/ 64" 449/ 64" 53/ 8" 715/ 64" 717/ 64" 933/ 64" 123/ 16" 1217/ 64" 51/ 32" 151/ 32" 1/ 2" 211/ 64" 27/ 16" 23/ 4" 335/ 64" 323/ 32" 41/ 4" 55/ 32" 521/ 32" 661/ 64" 661/ 64" 413/ 32" 51/ 8" 515/ 16" 77/ 8" 77/ 8" 1015/ 64" 123/ 4" 1243/ 64" 1535/ 64" 1535/ 64" 15/ 32" 13/ 8" 123/ 32" 215/ 64" 23/ 8" 229/ 32" 313/ 32" 41/ 64" 55/ 32" 55/ 32" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Type C Dimensions – Threaded & Set Screw Conduit Size 1/ 2" Outlet Bodies 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" A B C D E F 15/ 16" 117/ 32" 13/ 4" 217/ 32" 217/ 32" 27/ 32" 41/ 2" 41/ 2" 51/ 2" 51/ 2" 327/ 32" 419/ 32" 511/ 32 71/ 4" 71/ 4" 97/ 16" 121/ 4" 121/ 4" 15" 15" 1/ 2" 11/ 2" 15/ 8" 129/ 32" 23/ 4" 23/ 4" 313/ 32" 41/ 2" 41/ 2" 59/ 16" 59/ 16" 427/ 32" 541/ 64" 61/ 2" 81/ 2" 81/ 2" 103/ 4" 13" 13" 165/ 16" 165/ 16" 11/ 8" 15/ 16" 11/ 2" 21/ 4" 21/ 4" 23/ 4" 41/ 2" 41/ 2" 51/ 2" 51/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Type LL Dimensions – Threaded & Set Screw Conduit Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 118 A B C D E F 13/ 32" 37/ 8" 1/ 2" 2" 211/ 32" 21/ 2" 313/ 32" 313/ 32" 327/ 32" 53/ 4" 53/ 4" 61/ 8" 61/ 8" 49/ 32" 113/ 32" 11/ 4" 11/ 2" 21/ 4" 21/ 4" 23/ 4" 45/ 8" 45/ 8" 57/ 16" 57/ 16" 421/ 32" 523/ 64" 717/ 64" 717/ 64" 915/ 32" 121/ 4" 121/ 4" 15" 15" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" US: 1-866-764-5454 CAN: 1-800-265-0502 51/ 8" 599/ 64" 755/ 64" 755/ 64" 1013/ 64" 13" 13" 165/ 16" 165/ 16" 113/ 32" 17/ 8" 27/ 8" 27/ 8" 327/ 64" 41/ 2" 41/ 2" 59/ 16" 59/ 16" Copyright© 2007 Cooper Crouse-Hinds • Rigid and combination Rigid or IMC and EMT Conduit Outlet Bodies • Die Cast Aluminum Conduit Outlet Bodies Series 5 Dimensions Type LR Dimensions – Threaded & Set Screw Conduit Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" A B C D E F 17/ 64" 11/ 4" 11/ 2" 21/ 4" 21/ 4" 23/ 4" 47/ 16" 45/ 8" 57/ 16" 57/ 16" 37/ 8" 421/ 32" 523/ 64" 717/ 64" 717/ 64" 915/ 32" 121/ 4" 121/ 4" 15" 15" 1/ 2" 2" 211/ 32" 21/ 2" 313/ 32" 313/ 32" 327/ 32" 513/ 16" 513/ 16" 61/ 8" 61/ 8" 49/ 32" 51/ 8" 559/ 64" 755/ 64" 755/ 64" 1013/ 64" 121/ 4" 121/ 4" 15" 15" 113/ 32" 141/ 64" 17/ 8" 27/ 8" 27/ 8" 327/ 64" 41/ 2" 41/ 2" 61/ 4" 61/ 4" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Type T Dimensions – Threaded & Set Screw Conduit Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" A B C D E F 15/ 16" 117/ 16" 125/ 32" 21/ 2" 21/ 2" 31/ 4" 41/ 2" 41/ 2" 51/ 2" 51/ 2" 327/ 32" 439/ 64" 53/ 8" 71/ 4" 71/ 4" 97/ 16" 121/ 4" 121/ 4" 15" 15" 1/ 2" 13/ 8" 141/ 64" 129/ 32" 23/ 4" 23/ 4" 327/ 64" 41/ 2" 41/ 2" 59/ 16" 59/ 16" 427/ 32" 519/ 32" 61/ 2" 81/ 2" 81/ 2" 1013/ 16" 13" 13" 165/ 16" 165/ 16" 21/ 16" 211/ 32" 219/ 32" 335/ 64" 335/ 64" 43/ 64" 525/ 32" 525/ 32" 613/ 16" 613/ 16" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Outlet Bodies US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 119 Conduit Outlet Bodies Form 5 • • • • • Rigid Conduit Outlet Bodies Malleable Iron Stainless Steel Cover Screws Integral Gasket Covers Available in SnapPack™† Applications: Standard Materials: Form 5 Malleable Iron Conduit Bodies are used in conduit systems to: • Act as pull outlets for conductors being installed • Provide openings for making splices and taps in conductors • Act as mounting outlets for lighting fixtures and wiring devices • Connect conduit sections • Provide taps for branch conduit runs • Make 90 degree bends in conduit runs • Provide for access to conductors for maintenance and future system changes • • • • Features: Standard Finishes: • • • • Malleable iron – electrogalvanized and aluminum acrylic paint Neoprene – natural Sheet steel – electrogalvanized Stainless steel – natural Certifications and Compliances: • UL Standard 514B • cUL to CSA Standard C22.2 No. 18 Outlet Bodies • Interchangeable with Appleton Form 35 Conduit Bodies • Built–in rollers on 11/ 4" to 4" C and LB bodies to facilitate wire pulling • Smooth and rounded integral bushings for protection of wire insulation • Solid neoprene gaskets may be converted to open type by pulling out perforated center section • Stainless steel cover screws • Domed sheet steel covers provide additional cubic capacity • Integral gasket cover provides NEMA 4 rating Bodies – Malleable iron Gaskets – Neoprene Covers – sheet steel or malleable Cover screws – stainless steel Form 35 is a registered trademark of Appleton Electric/EGS. 120 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds • Rigid Conduit Outlet Bodies • Malleable Iron Conduit Outlet Bodies Form 5 Options: Type LR ‡ Description ‡Snapack™ -packaged body, cover and neoprene gasket Available on all sizes Suffix CG Type LB ‡ Cat.# Internal Vol. in Size Cu. In. Cat.# LB50M LB75M LB100M LB125M* LB150M* LB200M* LB250M* LB300M* LB350M* LB400M* 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Internal Vol. in Size Cu. In. 4.5 7.5 12.5 32.0 35.3 73.0 142.0 173.0 292.0 324.0 Wt. Unit Lbs. Qty. Per 100 10 10 10 5 5 1 1 1 1 1 71 97 143 287 331 534 1105 1160 1989 2099 Max. # of Conductors 3 3 3 3 N/A 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #2 XHHW MAX. 3 #1/0 XHHW MAX. 3 #4/0 XHHW MAX. #300 MCM XHHW MAX. #400 MCM XHHW MAX. #500 MCM XHHW MAX. #500 MCM XHHW MAX. LR50M LR75M LR100M LR125M LR150M LR200M LR250M LR300M LR350M LR400M 1/ 2" LL50M LL75M LL100M LL125M LL150M LL200M LL250M LL300M LL350M LL400M 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 4.5 7.5 12.5 32.0 33.0 68.0 142.0 173.0 292.0 324.0 10 10 10 5 5 1 1 1 1 1 76 95 138 309 332 497 1105 1437 2321 2431 Max. # of Conductors 3 3 3 3 N/A 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #2 XHHW MAX. 3 #2 XHHW MAX. 3 #4/0 XHHW MAX. #300 MCM XHHW MAX. #350 MCM XHHW MAX. #350 MCM XHHW MAX. #350 MCM XHHW MAX. T50M T75M T100M T125M T150M T200M T250M T300M T350M T400M Size Cat.# C50M C75M C100M C125M* C150M* C200M* C250M* C300M* C350M* C400M* Internal Vol. in Size Cu. In. 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 4.5 7.5 12.5 35.0 35.3 75.0 153.0 181.0 290.0 320.0 Wt. Unit Lbs. Qty. Per 100 10 10 10 5 5 1 1 1 1 1 98 118 170 309 368 552 1216 1437 2210 2321 Max. # of Conductors 3 3 3 3 N/A 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #2 XHHW MAX. 3 #1/0 XHHW MAX. 3 #4/0 XHHW MAX. #300 MCM XHHW MAX. #300 MCM XHHW MAX. #350 MCM XHHW MAX. #350 MCM XHHW MAX. *1 1/ 4" – 4" LB and C Bodies supplied with built in rollers to facilitate wire pulling. US: 1-866-764-5454 CAN: 1-800-265-0502 Unit Qty. Wt. Lbs. Per 100 6.0 9.5 15.0 33.0 36.0 76.0 142.0 173.0 292.0 324.0 10 10 10 5 5 1 1 1 1 1 111 137 196 332 368 663 1271 1547 2542 2542 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 3 3 3 3 N/A 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #2 XHHW MAX. 3 #2 XHHW MAX. 3 #4/0 XHHW MAX. #300 MCM XHHW MAX. #350 MCM XHHW MAX. #350 MCM XHHW MAX. #350 MCM XHHW MAX. Max. # of Conductors 3 3 3 3 N/A 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #2 XHHW MAX. 3 #1 XHHW MAX. 3 #2/0 XHHW MAX. #300 MCM XHHW MAX. #300 MCM XHHW MAX. #350 MCM XHHW MAX. #350 MCM XHHW MAX. Type TB ‡ Cat.# Type C ‡ Internal Vol. in Cu. In. 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 71 100 157 332 345 626 1105 1437 2321 2500 Size 1/ 2" TB50M TB75M TB100M TB125M TB150M TB200M 3/ 4" 1" 11/ 4" 11/ 2" 2" Internal Vol. in Cu. In. Unit Qty. Wt. Lbs. Per 100 Max. # of Conductors 6.0 9.5 15.0 33.0 36.0 76.0 10 10 10 5 5 1 88 120 197 342 420 691 N/A 3 #6 AWG MAX. 3 #6 AWG MAX. 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #1/0 XHHW MAX. Type X ‡ Cat.# X50M X75M X100M X125M X150M X200M Size 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Internal Vol. in Cu. In. Unit Qty. Wt. Lbs. Per 100 Max. # of Conductors 6.0 9.5 15.0 33.0 36.0 76.0 10 10 10 5 5 1 139 172 247 416 463 833 N/A 3 #6 AWG MAX. 3 #4 XHHW MAX. 3 #2 XHHW MAX. 3 #1/0 XHHW MAX. 3 #2/0 XHHW MAX. Copyright© 2007 Cooper Crouse-Hinds 121 Outlet Bodies Cat.# Wt. Unit Lbs. Qty. Per 100 10 10 10 5 5 1 1 1 1 1 Max. # of Conductors Type T ‡ Cat.# Internal Vol. in Size Cu. In. 4.5 7.5 12.5 32.0 35.3 68.0 142.0 173.0 292.0 324.0 3/ 4" *1 1/ 4" – 4" LB and C Bodies supplied with built in rollers to facilitate wire pulling. Type LL ‡ Wt. Unit Lbs. Qty. Per 100 • Rigid Conduit Outlet Bodies • Malleable Iron Conduit Outlet Bodies Form 5 Sheet Steel Covers Neoprene Gaskets with perforated Center Cat. # Size K50S K75S K100S K125S K200S K250S K350S 1/ 2" 3/ 4" 1" & 11/ 2" 2" 21/ 2" & 3" 31/ 2" & 4" 11/ 4" Unit Qty. Wt. Lbs. Per 100 50 50 25 20 5 5 5 9 13 19 31 50 94 138 1/ 2" GK50N GK75N GK100N GK125N GK200N GK250N GK350N 3/ 4" 1" 11/ 4" & 11/ 2" 2" 21/ 2" & 3" 31/ 2" & 4" Size 1/ 2" 3/ 4" 1" & 11/ 2" 2" 21/ 2" & 3" 31/ 2" & 4" 11/ 4" Unit Qty. Wt. Lbs. Per 100 50 50 25 20 5 5 5 23 31 41 91 208 358 550 Cat. # K50SG K75SG K100SG K125SG K200SG K250SG K350SG Size 1/ 2" 3/ 4" 1" 11/ 4" & 11/ 2" 2" 21/ 2" & 3" 31/ 2" & 4" Outlet Bodies K50CM K75CM K100CM K125CM K200CM K250CM K350CM 122 Unit Qty. Size 100 100 50 25 25 25 25 Sheet Steel Cover with Integral Gasket Cast Iron Covers Cat. # Cat. # US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Unit Qty. Wt. Lbs. Per 100 50 50 25 20 5 5 5 14 16 46 62 70 190 340 • Rigid Conduit Outlet Bodies • Malleable Iron Conduit Outlet Bodies Form 5 Dimensions Dimensions In Inches: Form 5 Iron LB Size A B C 1/ 2 3/ 4 1 11/4 11/2 2 21/2 3 31/2 4 1.34 4.68 2.05 1.50 5.37 2.25 1.80 6.20 2.65 2.60 8.12 2.75 2.60 8.12 2.83 3.12 10.50 4.42 4.31 13.60 5.40 4.31 13.87 5.90 5.62 16.25 6.90 5.62 16.60 7.21 1/ 2 3/ 4 1 11/4 11/2 2 21/2 3 31/2 4 2.05 4.68 1.37 2.25 5.37 1.70 2.65 6.20 1.90 2.75 8.12 2.75 3.50 8.12 2.83 4.12 10.50 3.31 5.71 13.60 3.90 5.87 13.87 4.75 7.13 16.50 6.81 7.13 16.50 7.19 1/ 2 3/ 4 1 11/4 11/2 2 21/2 3 31/2 4 2.05 4.68 1.37 2.25 5.37 1.70 2.65 6.20 1.90 2.75 8.12 2.75 3.50 8.12 2.83 4.12 10.50 3.31 5.71 13.60 3.90 5.87 13.87 4.75 6.10 6.25 5.62 6.95 16.25 5.62 1/ 2 3/ 4 1 11/4 11/2 2 21/2 3 31/2 4 1.34 5.38 1.37 1.50 6.00 1.70 1.80 7.05 1.90 2.60 9.00 2.75 2.60 9.00 2.83 3.12 11.50 3.31 4.31 15.00 3.90 4.31 15.12 4.75 4.88 18.13 5.19 4.88 18.13 5.56 1/ 2 3/ 4 1 11/4 11/2 2 21/2 3 31/2 4 2.05 5.38 1.34 2.25 6.00 1.50 2.65 7.05 1.80 2.75 9.00 2.60 3.50 9.00 2.60 4.12 11.50 3.12 5.71 15.00 4.31 5.87 15.12 4.31 6.81 18.13 5.19 7.15 18.13 5.56 Form 5 Iron LL Conduit A B C Form 5 Iron LR Conduit A B C Form 5 Iron C A B C Outlet Bodies Conduit Form 5 Iron T Conduit A B C Form 5 Iron TB Conduit A B C 1/ 2 3/ 4 1 11/4 11/2 2 1.34 5.38 2.05 1.50 6.00 2.25 1.80 7.05 2.65 2.60 9.00 2.75 2.60 9.00 2.83 3.12 11.50 4.42 1/ 2 3/ 4 1 11/4 11/2 2 2.79 5.41 1.75 2.93 6.08 1.97 3.56 7.1 2.25 4.43 9.1 2.55 4.43 9.1 2.75 5.4 11.75 3.45 Form 5 Type X Conduit A B C US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 123 Sealing Locknuts Applications UL File No. E-19189 Only one Sealing Locknut is required to: • Functionally replace rigid threaded enclosure connectors. • Provide raintight, watertight, or oiltight seal in any position. • Provide positive ground connection. • Provide economies in installation and fitting costs. Features And Benefits: Sealing Locknuts • Integrally fused PVC gasket provides positive seal against water, oils and other liquids. • Designed for use with raintight, watertight and oiltight enclosures, NEMA 2, 3, 3R, 4 and 12. • UL Listed Raintight. • UL Listed Liquidtight. • Can be used with either sheet metal or standard cast metal boxes. • CSA Certified watertight. • 1/ 2" – 2" Heavy-duty steel. • 21/ 2" – 6" Malleable iron. • U.S. Patent #4022262 124 Cat. # Size SL1 SL2 SL3 SL4 SL5 SL6 SL7 SL8 SL9 SL10 SL11 SL12 1/ 2" US: 1-866-764-5454 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" CAN: 1-800-265-0502 Unit Qty. Std. Pkg. Wt. Lbs. Per 100 100 50 25 25 25 25 10 10 10 5 2 1 100 500 250 250 100 100 50 50 50 25 2 1 1 2 4 4 5 8 28 38 46 52 125 140 Copyright© 2007 Cooper Crouse-Hinds • Liquidator™ Liquidtight Flexible Metallic Conduit Fittings Liquidtight Conduit Fittings Features and Benefits: UL File No. E-19189 Applications: Certifications and Compliances: • NEC/CEC: Class I, Division 2 Class II, Divisions 1 and 2 Class III, Divisions 1 and 2 • UL Standards: 514B, 467 • CSA Standard: C22.2 No. 18 US: 1-866-764-5454 CAN: 1-800-265-0502 Standard Materials: • Body – Straight: 3/ 8" through 6" – malleable iron or aluminum 45° and 90°; 3/ 8" through 4" – malleable iron or aluminum • Gland nut – malleable iron or aluminum • Ferrule – 3/ 8" through 6" – steel • Gland nut sealing ring – polyethylene • Sealing gasket – thermoplastic elastomer • Locknut – steel Standard Finishes: • Malleable iron – zinc electroplate • Polyethylene, thermoplastic elastomer, aluminum and die cast – natural User Benefits: • Assurance of safe and reliable performance. End user peace of mind. • Meets NEC and UL requirements for use in wet locations. Reduces downtime and replacement costs. • Complete selection of styles and sizes. Easy selection from one source, saves time and money. • High strength and excellent corrosion resistance. Long service life, eliminates the need for replacement. • Provides excellent pullout strength and grounding for safety of personnel and equipment. • Easy to install. Cannot be installed incorrectly. Saves labor. • Eliminates leakage, potential downtime and replacement costs. Protection against vibration. • Can be disassembled and reused. Cost savings. • Easy wrenching, Fast, easy installation results in labor savings. • Eliminates leakage, potential downtime and replacement costs. • Provides a reliable ground and safety of personnel and equipment. Won’t vibrate loose. • One-stop source to meet user needs. Saves time and money. Copyright© 2007 Cooper Crouse-Hinds 125 Liquidtight Typical applications for liquidtight conduit and the Liquidator include the wiring of machine tools… motors… transformers… food processing equipment… robotics… air conditioning units… illuminated store front signs and billboards… etc. The flexible metallic conduit and fittings protect conductors from mechanical damage due to vibration and movement and seals out cutting oils, coolants, water, dust, etc. Applications such as these can be found in, but are not limited to, industries such as: • Machine tool manufacturers. • Electric power generating plants. • Waste treatment facilities. • Paint manufacturing facilities. • Automobile manufacturing facilities. • Aerospace industries. • Breweries. • Food processing plants. • Dairies. • Pulp and paper mills. • Petroleum refineries. • Chemical and petrochemical plants. • UL and cUL Listed. • Provided protection in wet locations. • Straight available in 3/ 8" through 6" sizes; 45° and 90° available in 3/ 8" through 4" sizes. • Malleable iron bodies and gland nuts with zinc electroplate; steel ferrules and locknuts with zinc electroplate. • Cupped grounding ferrule is distortion-free and reusable. • Split polyethylene sealing ring is reversible. • Grooves inside sealing ring. Jacket of liquidtight conduit will cold flow into grooves. • Reusable design. • Hex surfaces on gland nut and body. • Thermoplastic elastomer sealing gasket effectively seals out oil, dust and dirt. • Steel locknut bites into box. • Available with or without insulated throats. • Insulated throat versions, 105°C rated nylon. • Liquidator™ Liquidtight Flexible Metallic Conduit Fittings Liquidtight Conduit Fittings Straight Connectors – Non-Insulated – Malleable Iron Cat. # LT38 LT50 LT75 LT100 LT125 LT150 LT200 LT250 LT300 LT350 LT400 LT500† LT600† Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 25 5 5 2 1 1 1 1 1 1 1 100 100 100 50 25 20 10 5 5 5 5 1 1 18 20 26 45 69 85 120 340 430 510 600 800 1075 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" †Not UL Listed or CSA Certified Straight Connectors – Insulated – Malleable Iron Liquidtight Cat. # LTB38 LTB50 LTB75 LTB100 LTB125 LTB150 LTB200 LTB250 LTB300 LTB350 LTB400 LTB500† LTB600† Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 25 5 5 2 1 1 1 1 1 1 1 100 100 100 50 25 20 10 5 5 5 5 1 1 18 20 26 45 69 86 120 340 430 510 600 800 1075 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" †Not UL Listed or CSA certified Straight Connectors – Non-Insulated – Aluminum Cat. # LT38 SA LT50 SA LT75 SA LT100 SA LT125 SA LT150 SA LT200 SA LT250 SA LT300 SA LT350 SA LT400 SA 126 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 25 10 5 2 1 1 1 1 1 100 100 100 50 25 20 10 5 5 5 5 12 12 14 28 34 48 54 121 174 245 279 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" US: 1-866-764-5454 CAN: 1-800-265-0502 45° Angle Connectors — Non-Insulated – Malleable Iron Cat. # LT3845 LT5045 LT7545 LT10045 LT12545 LT15045 LT20045 LT25045 LT30045 LT35045 LT40045 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 27 29 41 70 93 137 199 600 925 1150 1450 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 45° Angle Connectors – Insulated – Malleable Iron Cat. # LTB3845 LTB5045 LTB7545 LTB10045 LTB12545 LTB15045 LTB20045 LTB25045 LTB30045 LTB35045 LTB40045 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 27 29 41 70 93 137 195 600 925 1150 1450 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 90° Angle Connectors – Non-Insulated – Malleable Iron Cat. # LT3890 LT5090 LT7590 LT10090 LT12590 LT15090 LT20090 LT25090 LT30090 LT35090 LT40090 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 31 33 48 76 112 155 230 900 1383 1875 2325 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds • Liquidator™ Liquidtight Flexible Metallic Conduit Fittings • Zinc Die Cast Liquidtight Fittings Liquidtight Conduit Fittings 90° Angle Connectors – Insulated – Malleable Iron SELF RETAINING PVC GASKET WITH STEEL RING UL File no. E-22133 Cat. # LTB3890 LTB5090 LTB7590 LTB10090 LTB12590 LTB15090 LTB20090 LTB25090 LTB30090 LTB35090 LTB40090 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 30 33 48 76 112 155 230 900 1380 1825 2325 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 90° Angle Connectors – Non-Insulated – Aluminum Cat. # Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 10 10 5 2 1 100 100 50 50 25 10 5 19 18 24 40 48 61 86 LT3890 SA LT5090 SA LT7590 SA LT10090 SA LT12590 SA LT15090 SA LT20090 SA 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" SG1 SG2 SG3 SG4 SG5 SG6 SG7 SG8 SG9 SG10 SG11 SG12 Conduit Size Unit Qty. Wt. Lbs. Per 100 3/ 8" 100 50 50 25 25 25 10 10 10 10 5 5 1 2 2 2 4 3 5 10 12 10 15 22 – 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" ZINC DIE CAST LIQUIDTIGHT FITTING Applications: To terminate and seal liquidtight flexible metal conduit to oiltight, liquidtight, or raintight box or enclosure. Connectors can be used with tapered thread female entry or unthreaded knockout using the provided sealing washer and lock nut. Features: • Furnished with lock nut and sealing ring • Liquidtight/Raintight/Oiltight • Suitable for wet locations Liquidtight Combination Couplings For Coupling Liquidtight To Threaded RIGID/IMC Conduit Cat. # Standard Materials: • Zinc Die Cast Standard Finishes: • Natural Cat. # LTR38* LTR50 LTR75 LTR100 LTR125 LTR150 LTR200 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 25 25 25 5 2 2 1 100 100 100 50 20 20 10 17 29 33 59 105 105 160 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" *For 3/ 8" Liquidtight to 1/ 2" Rigid/IMC Straight Connectors – Non-Insulated Cat. # LT38DC LT50DC LT75DC LT100DC LT125DC LT150DC LT200DC LT250DC LT300DC LT350DC LT400DC US: 1-866-764-5454 CAN: 1-800-265-0502 Conduit Size Unit Qty. Std. Pkg. A B C D 3/ 8" 25 25 15 8 5 4 2 1 1 1 1 250 250 150 80 50 40 20 10 10 6 6 1.07 1.07 1.07 1.34 1.15 1.52 1.54 2.20 2.22 2.36 2.44 .96 1.08 1.33 1.56 1.94 2.19 2.66 3.28 3.80 4.28 4.78 .62 .62 .82 1.02 1.36 1.60 2.07 2.51 3.13 3.58 4.05 .47 .47 .47 .57 .71 .71 .71 1.06 1.06 1.06 1.06 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds 127 • Zinc Die Cast Liquidtight Fittings • Grounding Type Liquidtight Flexible Metallic Conduit Fittings Liquidtight Conduit Fittings LIQUIDATOR™ LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT FITTINGS WITH GROUND LUG Straight Connectors – Insulated For Liquidtight Flexible Steel Conduit Cat. # LTB38DC LTB50DC LTB75DC LTB100DC LTB125DC LTB150DC LTB200DC LTB250DC LTB300DC LTB350DC LTB400DC Conduit Size Unit Qty. Std. Pkg. A B C D 3/ 8" 25 25 15 8 5 4 2 1 1 1 1 250 250 150 80 50 40 20 10 10 6 6 1.44 1.44 1.56 2.01 2.18 2.19 2.21 2.89 2.93 3.07 3.15 .96 1.08 1.33 1.56 1.94 2.19 2.66 3.28 3.80 4.28 4.78 .62 .62 .82 1.02 1.36 1.60 2.07 2.51 3.13 3.58 4.05 .47 .47 .47 .57 .71 .71 .71 1.06 1.06 1.06 1.06 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" UL File No. E-6225 Applications: • Lazy-Lug liquidtight conduit fittings provide an easy, versatile method to use an external grounding conductor with liquidtight flexible metallic conduit as permitted by the National Electrical Code. • This section allows an external bonding jumper to be used with a 6foot or shorter length of liquidtight conduit. 90° Angle Connectors – Non-Insulated UL File No. E-19189 Features and Benefits: Liquidtight Cat. # LT3890DC LT5090DC LT7590DC LT10090DC LT12590DC LT15090DC LT20090DC LT25090DC LT30090DC LT35090DC LT40090DC Conduit Size Unit Qty. Std. Pkg. A B C D 3/ 8" 25 25 15 8 5 4 2 1 1 1 1 250 250 150 80 50 40 20 10 10 6 6 .62 .62 .80 1.02 1.36 1.61 2.08 2.51 3.13 3.58 4.06 .81 .91 1.15 1.38 1.77 2.01 2.58 3.15 3.67 4.17 4.74 .92 1.02 1.27 1.48 1.93 2.17 2.68 3.21 3.74 4.23 4.75 1.22 1.22 1.36 1.73 2.11 2.43 2.93 3.62 4.28 4.84 5.37 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" • Open lug design allows installer to quickly lay in the grounding conductor. • Aluminum lug – for copper or aluminum grounding conductors. • Copper lug – for copper grounding conductors. Certifications and Compliances: • UL Standard 514B – Fittings for Conduit and Outlet Boxes • UL Standard 467 – Grounding and Bonding Equipment Straight Connectors – Non-Insulated – Malleable Iron – Aluminum Lug 90° Angle Connectors – Insulated Cat. # Cat. # LTB3890DC LTB5090DC LTB7590DC LTB10090DC LTB12590DC LTB15090DC LTB20090DC LTB25090DC LTB30090DC LTB35090DC LTB40090DC 128 Conduit Size Unit Qty. Std. Pkg. A B C D 3/ 8" 25 25 15 8 5 4 2 1 1 1 1 250 250 150 80 50 40 20 10 10 6 6 .62 .62 .80 1.02 1.36 1.61 2.08 2.51 3.13 3.58 4.06 .81 .91 1.15 1.38 1.77 2.01 2.58 3.15 3.67 4.17 4.74 .92 1.02 1.27 1.48 1.93 2.17 2.68 3.21 3.74 4.23 4.75 1.22 1.22 1.36 1.73 2.11 2.43 2.93 3.62 4.28 4.84 5.37 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" US: 1-866-764-5454 CAN: 1-800-265-0502 LT38G LT50G LT75G LT100G LT125G LT150G LT200G LT250G LT300G LT350G LT400G LT500G† LT600G† Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 250MCM – #6 250MCM – #6 25 25 25 5 5 2 1 1 1 1 1 1 1 100 100 100 50 25 20 10 5 5 5 5 1 1 18 20 26 45 69 85 120 340 430 510 600 800 1100 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" †Not UL Listed Copyright© 2007 Cooper Crouse-Hinds Liquidtight Conduit Fittings • Zinc Die Cast Liquidtight Fittings • Grounding Type Liquidtight Flexible Metallic Conduit Fittings Straight Connectors – Insulated – Malleable Iron – Aluminum Lug 45° Angle Connectors – Insulated – Malleable Iron – Aluminum Lug Cat. # LTB38G LTB50G LTB75G LTB100G LTB125G LTB150G LTB200G LTB250G LTB300G LTB350G LTB400G LTB500G† LTB600G† Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 250MCM – #6 250MCM – #6 25 25 25 5 5 2 1 1 1 1 1 1 1 100 100 100 50 25 20 10 5 5 5 5 1 1 18 20 26 45 69 86 120 340 430 510 600 720 750 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" †Not UL Listed Note: Cat. # LTB3845G LTB5045G LTB7545G LTB10045G LTB12545G LTB15045G LTB20045G LTB25045G LTB30045G LTB35045G LTB40045G Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – # #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 10 10 5 2 1 1 1 1 — 100 100 50 50 25 10 5 1 1 1 1 29 41 41 70 93 137 195 600 925 1150 1450 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 90° Angle Connectors – Non-Insulated – Malleable Iron – Aluminum Lug For other connector and lug combinations, consult factory. Straight Connectors – Non-Insulated – Aluminum – Aluminum Lug Cat. # Cat. # Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 25 5 5 2 1 1 1 1 1 25 25 25 5 5 2 1 1 1 1 1 12 12 14 28 34 48 54 121 174 245 279 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" US: 1-866-764-5454 CAN: 1-800-265-0502 Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 32 33 48 76 112 155 230 900 1383 1875 2325 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Copyright© 2007 Cooper Crouse-Hinds Liquidtight LT38G SA LT50G SA LT75G SA LT100G SA LT125G SA LT150G SA LT200G SA LT250G SA LT300G SA LT350G SA LT400G SA Conduit Size LT3890G LT5090G LT7590G LT10090G LT12590G LT15090G LT20090G LT25090G LT30090G LT35090G LT40090G Conduit Size 129 • Zinc Die Cast Liquidtight Fittings • Grounding Type Liquidtight Flexible Metallic Liquidtight Conduit Fittings 90° Angle Connectors – Insulated – Malleable Iron – Aluminum Lug GROUNDING TYPE LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT FITTINGS Straight Connectors – Insulated – Copper Lug Cat. # LTB3890G LTB5090G LTB7590G LTB10090G LTB12590G LTB15090G LTB20090G LTB25090G LTB30090G LTB35090G LTB40090G Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #83 #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 — 5 1 1 1 1 30 33 48 76 112 155 230 900 1300 1800 2300 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 90° Angle Connectors – Non-Insulated – Aluminum – Aluminum Lug Cat. # LTB38GC LTB50GC LTB75GC LTB100GC LTB125GC LTB150GC LTB200GC LTB250GC LTB300GC LTB350GC LTB400GC Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 25 5 5 2 1 1 1 1 1 100 100 100 50 25 20 10 5 5 5 5 20 22 28 47 71 88 122 351 441 532 622 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 45° Angle Connectors – Insulated – Copper Lug Conduit Size Liquidtight Cat. # LT3890G SA LT5090G SA LT7590G SA LT10090G SA LT12590G SA LT15090G SA LT20090G SA Note: 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Lug Size #4 #4 #4 #4 #4 #4 #4 – – – – – – – #14 #14 #14 #14 #14 #14 #14 Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 25 10 10 5 2 1 25 25 25 5 5 2 1 19 18 24 40 48 61 86 For other connector and lug combinations, consult factory. Cat. # LTB3845GC LTB5045GC LTB7545GC LTB10045GC LTB12545GC LTB15045GC LTB20045GC LTB25045GC LTB30045GC LTB35045GC LTB40045GC Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 31 43 43 72 95 139 197 611 936 1172 1472 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 90° Angle Connectors – Insulated – Copper Lug Cat. # LTB3890GC LTB5090GC LTB7590GC LTB10090GC LTB12590GC LTB15090GC LTB20090GC LTB25090GC LTB30090GC LTB35090GC LTB40090GC Note: 130 US: 1-866-764-5454 CAN: 1-800-265-0502 Conduit Size Lug Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #4 – #14 #1/0 – #8 #1/0 – #8 #3/0 – #6 #3/0 – #6 25 25 10 10 5 2 1 1 1 1 1 100 100 50 50 25 10 5 1 1 1 1 32 35 50 78 114 157 232 911 1311 1822 2322 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" For other connector and lug combinations, consult factory. Copyright© 2007 Cooper Crouse-Hinds • Combination Couplings for Coupling Liquidtight to Threaded Rigid/IMC – Grounding Type – Aluminum Lug • Wire Mesh Grips for Liquidtight Metallic Conduit Fittings Liquidtight Conduit Fittings COMBINATION COUPLINGS FOR COUPLING LIQUIDTIGHT TO THREADED RIGID/IMC – GROUNDING TYPE – ALUMINUM LUG Conduit Size Cat. # LTR38G* LTR50G LTR75G LTR100G LTR125G LTR150G LTR200G 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Lug Size #4 #4 #4 #4 #4 #4 #4 – – – – – – – #14 #14 #14 #14 #14 #14 #14 Unit Qty. Std. Pkg. Wt. Lbs. Per 100 25 25 25 5 5 2 1 100 100 100 50 25 20 10 24 30 35 59 81 107 162 *For 3/ 8" Liquidtight to 1/ 2" Rigid/IMC Note: For other connector and lug combinations, consult factory. Copper lugs are available also. Consult factory for details. REPLACEMENT LIQUIDTIGHT FERRULES For Steel Connectors Only Cat. # FEA38 FEA50 FEA75 FEA100 FEA125 FEA150 FEA200 FEA250 FEA300 FEA350 FEA400 Conduit Size Unit Qty. 3/ 8" 100 100 100 100 50 50 10 10 10 10 10 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" WIRE MESH GRIPS FOR LIQUIDTIGHT METALLIC CONDUIT FITTINGS Applications: Liquidtight • Wire mesh grips are used with Liquidator liquidtight conduit fittings to prevent conduit pullout due to stress, tension, strain, vibration, or movement. • Typical applications include the wiring of machine tools, motors, transformers, food processing, equipment, robotics, or any application that requires a flexible liquidtight conduit connection. Wire Mesh Grip – Dimensions Dimensions Cat. # WMG38 WMG50 WMG75 WMG100 WMG125 WMG150 WMG200 Conduit Size 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" A B Unit Qty. Wt. Lbs. Per 100 67/ 16" 61/ 8" 615/ 16" 83/ 16" 103/ 4" 1113/ 16" 147/ 16" 11/ 4" 17/ 16" 15/ 8" 115/ 16" 23/ 8" 23/ 4" 35/ 16" 10 10 10 10 2 2 1 10 12 17 21 37 56 79 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 131 • LiQuik™ Liquidtight Fittings Liquidtight Conduit Fittings LiQuik™ LIQUIDTIGHT FITTINGS No disassembly required! The LiQuik liquidtight fittings are quick and easy to install in 2 steps, offering huge labor saving potential. Available in trade sizes 3/ 8"–2" straight insulated. Traditional Assembly Installation 1. Slide nut over conduit. 4. Slide the conduit assembly inside body. 2. Slide compression ring over conduit. 5. Slide compression nut and ring towards the connector. 3. Thread ferrule inside the conduit. 6. Tighten the nut. Liquidtight New LiQuik Assembly Installation In Just 2 Steps: 1. Slide conduit inside the fully assembled connector. 2. Turn the connector assembly or the conduit until the ferrule threads engage the spirals in the conduit. The pins in the ferrule are locked inside the holes in the connector body, preventing the ferrule from turning. Tighten the nut against the connector. LiQuik™ Liquidtight Fittings – Straight, Non-Insulated LiQuik™ Liquidtight Fittings – Straight, Insulated Dimensions Dimensions Cat. # LTQ38 LTQ50 LTQ75 LTQ100 LTQ125 LTQ150 LTQ200 Conduit Size KO Size Unit Qty. Wt. Lbs. Per 100 A B C 3/ 8" 1/ 2" 3/ 4" 15 18 29 40 55 71 99 11/ 8" 11/ 4" 11/ 4" 17/ 16" 11/ 2" 15/ 8" 13/ 4" 1/ 2" 3/ 4" 25 25 25 5 5 2 1 11/ 8" 11/ 4" 19/ 16" 113/ 16" 21/ 4" 27/ 16" 3" 1/ 2" 1" 11/ 4" 11/ 2" 2" 1/ 2" 1" 11/ 4" 11/ 2" 2" 1/ 2" 1/ 2" 5/ 8" 11/ 16" 3/ 4" 3/ 4" Cat. # LTQB38 LTQB50 LTQB75 LTQB100 LTQB125 LTQB150 LTQB200 Conduit Size KO Size 3/ 8" 1/ 2" 3/ 4" 3/ 4" 1/ 2" 1" 11/ 4" 11/ 2" 2" 1/ 2" 1" 11/ 4" 11/ 2" 2" Unit Qty. Wt. Lbs. Per 100 25 25 25 5 5 2 1 16 18 29 40 56 71 100 A B 11/ 8" 9/ 16" 11/ 8" 11/ 4" 9/ 16" 11/ 4" 11/ 4" 9/ 16" 19/ 16" 17/ 16" 11/ 16" 113/ 16" 11/ 2" 3/ 4" 21/ 4" 15/ 8" 13/ 16" 27/ 16" 13/ 4" 13/ 16" 3" Replacement LiQuik™ Ferrules Cat. # Conduit Size Wt. Lbs. Per 100 3/ 8" 100 100 100 100 50 50 10 LTQF38 LTQF50 LTQF75 LTQF100 LTQF125 LTQF150 LTQF200 132 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" C Liquidtight Conduit Fittings LTK Low Profile Series Applications: Standard Finishes: • Flexible metalic (liquidtight) conduit used with Cooper CrouseHinds® Liquidtight fittings is designed to protect conductors from mechanical damage due to vibration and movement while sealing out cutting oils, coolants, water, dust, etc. • Typical applications include the wiring of machine tools, motors, transformers, food processing equipment, robotics, air conditioning units, illuminated signs, etc. • The low profile liquidtight fittings are designed specifically for OEM applications that require close side-by-side mounting of multiple liquidtight fittings in tight spaces. • • • • Certifications and Compliances: • NEC: Class I, Division 2 (Zone 2) Class II, Division 1 and 2 Class III, Division 1 and 2 • UL Standards: 514B, 467 • CSA Standard: C22.2 No. 18 Standard Materials: • • • • • Body – steel (straight fittings), malleable iron (angle fittings) Gland nut – steel Ferrule – steel Gland nut sealing ring – nylon Sealing gasket – polypropylene Conduit Size Steel – zinc electroplate Malleable iron – zinc electroplate Nylon – natural Polypropylene – natural Insulated Cat. # Straight Connectors 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" LTK38 LTK50 LTK75 LTK100 LTK125 LTK150 LTK200 LTBK38 LTBK50 LTBK75 LTBK100 LTBK125 LTBK150 LTBK200 45° Connectors 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" LTK3845 LTK5045 LTK7545 LTK10045 LTK12545 LTK15045 LTK20045 LTBK3845 LTBK5045 LTBK7545 LTBK10045 LTBK12545 LTBK15045 LTBK20045 90° Connectors 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" LTK3890 LTK5090 LTK7590 LTK10090 LTK12590 LTK15090 LTK20090 LTBK3890 LTBK5090 LTBK7590 LTBK10090 LTBK12590 LTBK15090 LTBK20090 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Liquidtight Non-insulated Cat. # 133 Liquidtight Conduit Fittings LTK Low Profile Series Replacement Ferrules Conduit Size Cat. # 3/ 8" LTKF38 LTKF50 LTKF75 LTKF100 LTKF125 LTKF150 LTKF200 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Dimensions In Inches: Straight Connectors Conduit Size Over Round Corner A1 (in.) Over Hex A2 (in.) B (in.) 13/ 32 13/ 16 17/ 16 13/ 4 25/ 32 23/ 8 27/ 8 11/ 32 11/ 8 13/ 8 111/ 16 21/ 16 29/ 32 225/ 32 13/ 16 111/ 32 17/ 16 15/ 8 127/ 32 2 21/ 8 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" N.P.T. Thread Length C (in.) 19/ 32 19/ 32 19/ 32 21/ 32 43/ 64 23/ 32 23/ 32 45°Connectors Conduit Size Over Round Corner A1 (in.) Over Hex A2 (in.) B (in.) C (in.) 13/ 32 11/ 32 17/ 32 15/ 16 13/ 8 121/ 32 123/ 32 2 29/ 32 11/ 32 11/ 32 11/ 8 11/ 4 111/ 32 115/ 32 15/ 8 19/ 32 113/ 32 21/ 32 11/ 16 23/ 32 23/ 32 N.P.T. Thread Length D (in.) 3/ 8" 1/ 2" 13/ 16 17/ 16 13/ 4 25/ 32 23/ 8 27/ 8 11/ 32 13/ 8 111/ 16 21/ 16 29/ 32 225/ 32 Over Round Corner A1 (in.) Over Hex A2 (in.) B (in.) Over C (in.) 13/ 32 13/ 16 17/ 16 13/ 4 25/ 32 23/ 8 27/ 8 11/ 32 11/ 8 13/ 8 111/ 16 21/ 16 29/ 32 225/ 32 119/ 32 121/ 32 125/ 32 23/ 16 33/ 8 25/ 8 31/ 16 11/ 4 11/ 4 117/ 32 127/ 32 115/ 16 23/ 32 213/ 32 Liquidtight 3/ 4" 1" 11/ 4" 11/ 2" 2" N.P.T. Thread Length D (in.) 19/ 32 90° Connectors Conduit Size 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 134 US: 1-866-764-5454 CAN: 1-800-265-0502 19/ 32 19/ 32 113/ 32 21/ 32 11/ 16 23/ 32 23/ 32 Copyright© 2007 Cooper Crouse-Hinds Nonmetallic Liquidtight Conduit Fittings Applications: • For use with nonmetallic Type B liquidtight conduit to terminate and seal conduit to liquidtight, oiltight, or raintight box or enclosure. • Typical applications include wiring motors, transformers, processing equipment, pumps, etc. Features: • • • • • • Liquidtight, Raintight Oiltight Furnished with locknut and sealing ring Corrosion resistant Suitable for wet locations No-Spin ferrule 90° has smooth interior to prevent abrasion of conductors Standard Materials: • Body – Nylon • Locknut – Zinc Die Cast Straight Connectors Dimensions Cat. # LT50NM LT75NM LT100NM Unit Qty. Std. Pkg. Wt. Lbs. Per 100 A 1/ 2" 25 10 5 250 150 80 6 8 10 .55 .72 .94 Conduit Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 A 1/ 2" 25 10 5 150 100 50 7 9 13 .55 .72 .94 3/ 4" 1" B C .85 .56 1.08 .72 1.30 .94 Liquidtight Conduit Size 90° Connectors Dimensions Cat. # LT5090NM LT7590NM LT10090NM 3/ 4" 1" US: 1-866-764-5454 B C .85 .56 1.08 .72 1.30 .94 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 135 Cord And Cable Connectors CG Series Color-Coded Cord Grips Applications: Features: CG Series color-coded grips with neoprene bushings are for use with portable cords, including S, SO, STO, ST, SJ, SJT, SJTO, and SVO. CG cord grips are installed to: • Provide a means for passing a cord into an enclosure • Form a watertight seal for cord • Provide pullout protection for cord, ensuring a secure connection • Neoprene bushings are color coded by cable diameter for quick and easy identification of proper cord grip. • Rugged construction protects cord from damage. • Compact design permits close spacing of fittings on panel applications. • Tightening one nut creates watertight seal. • Male tapered thread NPT. • Available in straight, 45° and 90° entrance configurations. Standard Materials and Finishes: • • • • Straight Body – electrogalvanized steel Angled Body – electrogalvanized malleable iron Nut – electrogalvanized steel Bushing – neoprene/natural Certifications and Compliances: • • • • UL Standard: 514B CSA Standard: C22.2 No. 18 Suitable for NEMA 4 enclosures and other wet locations Suitable for use in hazardous locations when installed in accordance with NEC 501.4(B), 502.4(A) and 503.3(A). • For Class I, Div.2, Class II, Div. 1 and 2 and Class III, Div. 1 and 2. STRAIGHT BODY Cord & Cable Cat. # Trade Size Color Size Cable Range Min. Cable Range Max. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Red White Blue Green 0.15 0.25 0.35 0.45 0.25 0.35 0.45 0.56 25 25 25 25 100 100 100 100 10 10 10 10 Brown Red White Blue 0.55 0.15 0.25 0.35 0.65 0.25 0.35 0.45 25 10 10 10 100 50 50 50 10 14 14 14 3/ 4" Green Brown Yellow Purple 0.45 0.55 0.65 0.75 0.56 0.65 0.75 0.85 10 10 10 10 50 50 50 50 14 14 14 14 CG50 CG50 CG50 CG50 250 350 450 560 1/ 2" CG50 CG75 CG75 CG75 650 250 350 450 1/ 2" CG75 CG75 CG75 CG75 560 650 750 850 3/ 4" 1/ 2" 1/ 2" 1/ 2" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" CG100 CG100 CG100 CG100 560 650 750 850 1" 1" 1" 1" Green Brown Yellow Purple 0.45 0.55 0.65 0.75 0.56 0.65 0.75 0.85 5 5 5 5 25 25 25 25 20 20 20 20 CG100 CG100 CG125 CG125 950 1050 850 950 1" 1" 11/ 4" 11/ 4" Gray Black Purple Gray 0.85 0.95 0.75 0.85 0.95 1.05 0.85 0.95 5 5 5 5 25 25 25 25 20 20 40 40 CG125 CG125 CG125 CG125 1050 1150 1250 1375 11/ 4" 11/ 4" 11/ 4" 11/ 4" Black Orange Red White 0.95 1.05 1.15 1.25 1.05 1.15 1.25 1.375 5 5 5 5 25 25 25 25 40 40 40 40 CG150 CG150 CG150 CG150 1050 1150 1250 1375 11/ 2" 11/ 2" 11/ 2" 11/ 2" Black Orange Red White 0.95 1.05 1.15 1.25 1.05 1.15 1.25 1.375 2 2 2 2 10 10 10 10 70 70 70 70 136 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Cord And Cable Connectors CG Series Color-Coded Cord Grips 45° BODY Cat. # Trade Size Color Size Cable Range Min. Cable Range Max. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Red White Blue Green 0.15 0.25 0.35 0.45 0.25 0.35 0.45 0.56 10 10 10 10 50 50 50 50 24 24 24 24 Brown Red White Blue 0.55 0.15 0.25 0.35 0.65 0.25 0.35 0.45 10 10 10 10 50 50 50 50 24 36 36 36 3/ 4" Green Brown Yellow Purple 0.45 0.55 0.65 0.75 0.56 0.65 0.75 0.85 10 10 10 10 50 50 50 50 36 36 36 36 1" 1" 1" 1" Green Brown Yellow Purple 0.45 0.55 0.65 0.75 0.56 0.65 0.75 0.85 5 5 5 5 25 25 25 25 68 68 68 68 1" 1" Gray Black 0.85 0.95 0.95 1.05 5 5 25 25 68 68 CG5045 CG5045 CG5045 CG5045 250 350 450 560 1/ 2" CG5045 CG7545 CG7545 CG7545 650 250 350 450 1/ 2" CG7545 CG7545 CG7545 CG7545 560 650 750 850 3/ 4" CG10045 CG10045 CG10045 CG10045 560 650 750 850 CG10045 950 CG10045 1050 1/ 2" 1/ 2" 1/ 2" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 90° BODY Cat. # Color Size Cable Range Min. Cable Range Max. Unit Qty. Std. Pkg. Wt. Lbs. Per 100 Red White Blue Green 0.15 0.25 0.35 0.45 0.25 0.35 0.45 0.56 10 10 10 10 50 50 50 50 26 26 26 26 Brown Red White Blue 0.55 0.15 0.25 0.35 0.65 0.25 0.35 0.45 10 10 10 10 50 50 50 50 26 48 48 48 3/ 4" Green Brown Yellow Purple 0.45 0.55 0.65 0.75 0.56 0.65 0.75 0.85 10 10 10 10 50 50 50 50 48 48 48 48 1" 1" 1" 1" Green Brown Yellow Purple 0.45 0.55 0.65 0.75 0.56 0.65 0.75 0.85 5 5 5 5 25 25 25 25 68 68 68 68 1" 1" Gray Black 0.85 0.95 0.95 1.05 5 5 25 25 68 68 CG5090 CG5090 CG5090 CG5090 250 350 450 560 1/ 2" CG5090 CG7590 CG7590 CG7590 650 250 350 450 1/ 2" CG7590 CG7590 CG7590 CG7590 560 650 750 850 3/ 4" CG10090 CG10090 CG10090 CG10090 560 650 750 850 CG10090 950 CG10090 1050 1/ 2" 1/ 2" 1/ 2" 3/ 4" 3/ 4" 3/ 4" 3/ 4" 3/ 4" US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Cord & Cable Trade Size 137 Cord And Cable Connectors NCG Series Nonmetallic Cord Grips Applications: Features: For use with portable cord, NCG Series watertight cord grips terminate and protect conductors from mechanical damage due to vibration and movement. A neoprene bushing seals out oils, coolants, water, dust and other abusive agents. NCG cord grips may be used with types S, SO, STO, SJ, SJT, SJTO and SVO portable cords. Typical applications include the termination of wiring for: • Machine tools • Motors • Transformers • Food processing equipment • Robotics • Air conditioning units • Illuminated signs • Terminal boxes • Control cabinets • Available in 3/ 8" to 1" trade sizes. • Neoprene bushings cover a large cable range, reducing the number of different fittings required. • Polyamide nonmetallic construction stands up to most corrosive environments. • Polyamide locknut available, order separately. • UL listed and cUL third party certified. • Rain-tight and watertight construction for outdoor use. • Tightening one nut creates watertight seal. Certifications and Compliances: • • • • • Standard Materials: UL Standard 514B cUL to CSA Standard C22.2 No.18 IP 68 NEMA 4X Watertight Zone 2, Division 2 use per Code • Cable gland body and nut – polyamide 6 • Bushing – neoprene • Locknut – polyamide 6 Cat. # NCG38 35 NCG50 50 NCG75 75 NCG100 100 Trade Size Cable Range Inches (MM) Std. Pkg. 3/ 8" 0.1–0.35 (2.5–8) 0.20–0.50 (5–12) 0.35–0.75 (9–18) 0.55–1.00 (14–25) 25 25 25 20 1/ 2" 3/ 4" 1" Locknuts – must be ordered separately Cat. # Trade Size Std. Pkg. 3/ 8" 25 25 25 20 1/ 2" 3/ 4" 1" Cord & Cable 10N 11N 12N 13N 138 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds • Set Screw Type Connectors • Straight, 45°, and 90° Armored and Metal Clad Cable Fittings ACB Series Connectors ARMORED AND METAL CLAD CABLE CONNECTORS – STEEL ACB SERIES Applications: • ACB Series Connectors are used to connect armored cable, metal clad cable or flexible metallic conduit to a box or enclosure. Features and Benefits: • Dual gripping saddle design on the connector safely secures cable or conduit in place and prevents loosening from vibration. • Insulated throat provides a smooth pulling surface that won't strip cable. • Angled teeth on locknut bite into enclosure, preventing loosening from vibration. • Tri-head set screw may be installed using a slotted, Phillips or Robertson head Screwdriver. • Steel connector is zinc electroplated for corrosion resistance. 45° Connectors* Certifications and Compliances: Cable Opening • UL Listed • cUL Listed Cat. # Materials and Finishes: • • • • ACB3845 ACB5045 ACB7545 Body: Steel – Zinc electroplated Saddle: Steel – Zinc electroplated Screw: Steel – Zinc electroplated Insulated throat: Thermoplastic – Natural Trade Size 3/ 8" 1/ 2" 3/ 4" Max. Min. 0.656 0.437 0.937 0.750 1.125 0.906 Dimensions Unit Qty. Std. Pkg. 50 25 10 200 100 50 Unit Qty. Std. Pkg. A 50 25 10 5 200 100 50 25 13/ 4" 21/ 8" 21/ 2" 213/ 16" A B C 113/ 16" 113/ 16" 15/ 16" 21/ 8" 21/ 8" 11/ 4" 23/ 8" 23/ 8" 17/ 16" *45° not available in 1" size 90° Connectors Straight Connectors Cable Opening Cable Opening Cat. # 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Max. Min. Unit Qty. Std. Pkg. A 0.656 0.937 1.125 1.468 1.500 1.750 2.031 3.062 3.562 4.060 4.560 0.437 0.750 0.906 1.250 1.312 1.562 1.812 2.812 3.312 3.620 4.120 50 25 10 5 5 5 1 1 1 1 1 200 100 50 25 10 10 5 5 5 1 1 13/ 16" 13/ 8" 13/ 8" 19/ 16" 23/ 16" 27/ 16" 29/ 16" 211/ 16" 213/ 16" 215/ 16" 3" US: 1-866-764-5454 B C 11/ 4" 1/ 2" 11/ 4" 7/ 16" 17/ 16" 7/ 16" 113/ 16" 1/ 2" 21/ 8" 5/ 8" 21/ 2" 5/ 8" 5/ 8" 3" 35/ 8" 13/ 16" 41/ 4" 15/ 16" 1" 33/ 4" 53/ 16" 11/ 16" CAN: 1-800-265-0502 Cat. # ACB3890 ACB5090 ACB7590 ACB10090 Trade Size 3/ 8" 1/ 2" 3/ 4" 1" Max. Min. 0.656 0.937 1.125 1.468 0.437 0.750 0.906 1.250 Copyright© 2007 Cooper Crouse-Hinds Dimensions B C 21/ 16" 1" 21/ 4" 11/ 4" 21/ 2" 13/ 8" 27/ 8" 111/ 16" 139 Cable Fittings ACB38 ACB50 ACB75 ACB100 ACB125 ACB150 ACB200 ACB250 ACB300 ACB350 ACB400 Trade Size Dimensions • Compression Type Couplings • Set Screw Type Couplings • Space Saver ACB Armored and Metal Clad Cable Fittings ARMORED AND METAL CLAD COUPLINGS – STEEL ACC SERIES Applications: ARMORED AND METAL CLAD CONNECTORS – STEEL SPACE SAVER ACB SERIES Features: • ACC combination couplings are used to join EMT conduit to armored cable, metal clad cable or flexible metallic conduit. • Male threads on locknut allow for more room inside the box • Smooth pulling surface eliminates the need for insulated throat fittings and/or conduit bushings • Angled teeth on locknut bite into enclosure, preventing loosening from vibration • Dual gripping saddle design on the fitting safely secures cable or conduit in place and prevents loosening from vibration • Tri-head set screw may be installed using a slotted, Philips, or Robertson head screwdriver • Steel fitting is zinc electroplated for corrosion resistance • Suitable for use with steel or aluminum cables Features and Benefits: • Dual gripping saddle design on the coupling safely secures cable or conduit in place and prevents loosening from vibration • Steel compression ring & nut provide a strong, secure termination point for EMT conduit. • Tri-head set screw may be installed using a slotted, Phillips or Robertson head screwdriver. • Steel combination coupling is zinc electroplated for corrosion resistance. Materials and Finishes: • Body: Steel – Zinc electroplated • Saddle: Steel – Zinc electroplated • Screw: Steel – Zinc electroplated Certifications and Compliances: Certifications and Compliances: • UL Listed • cUL Listed • UL Listed • cUL Listed Compression Coupling: UL File No. E-22132 Cable Opening Cat. # ACC38 ACC50 ACC75 Trade Size 3/ 8" 1/ 2" 3/ 4" Max. Min. Unit Qty. 0.656 0.937 1.125 0.437 0.750 0.906 25 10 10 Cable Fittings Set-Screw Coupling: Cat. # ACCSS38* ACCSS50 ACCSS75 Cable Opening Cat. # Trade Size Unit Qty. Wt. Lbs. Per 100 3/ 8" 25 10 10 9 12 14 1/ 2" 3/ 4" SSACB38 SSACB50 SSACB75 SSACB100 Trade Size KO Size Max. Min. 3/ 8" 1/ 2" 3/ 4" 3/ 4" 1/ 2" 1" 1/ 2" 1" 0.640 0.930 1.125 1.405 *not UL Listed 140 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 0.280 0.635 0.810 0.775 Dimensions Unit Qty. Wt. Lbs. Per 100 50 25 20 5 9 12 14 30 A B 13/ 8" 3/ 4" 13/ 8" 11/ 16" 11/ 2" 11/ 4" 2" 19/ 16" • Set Screw • Quik-Lok • Duplex Armored and Metal Clad Cable Fittings ARMORED CABLE CONNECTORS – MALLEABLE IRON ARMORED CABLE CONNECTORS – MALLEABLE IRON Set Screw Type Duplex Type UL File No. E-19188 UL File No. E-19188 Cat. # Trade Size Diam. of Opening for Cable Diam. of Bushed Hole 702V 3/ 8" 5/ 8" 7/ 16" Unit Qty. Wt. Lbs. Per 100 100 For 2 conductor No.'s 14, 12 3 conductor No.'s 14, 12 4 conductor No. 14, 5/ 16" flex 7 QUICK-LOK® CONNECTORS FOR ARMORED AND METAL CLAD CABLE – STEEL Features: • No Locknut required • Single-unit or duplex construction with captive clamp • Connects 50 MC, AC, and Flex RW cable sizes with just three fittings • Easy to install: tilt, insert and snap down • Single unit construction eliminates loose component parts, integral green plastic insulated throat bushing provides maximum protection for wire installation • Concrete tight when taped Trade Size Diam. of Opening for Cable Diam. of Bushed Hole Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 5/ 8" 9/ 16" 25 100 20 90 Degree 3/ 8" 700* 5/ 8" 9/ 16" 25 100 14 Cat. # Straight 699* *UL Listed as grounding means. ARMORED & METAL CLAD – ZINC DIE CAST Duplex Type UL File No. E-19188 Cat. # Trade Size Diam. of Opening for Cable Diam. of Bushed Hole Unit Qty. Std. Pkg. Wt. Lbs. Per 100 2699* 3/ 8" 5/ 8" 9/ 16" 25 250 13 *UL Listed as grounding means. Standard Materials: • Tubular Steel Standard Finishes: • Zinc plated UL File No. E-19188 QLK50S Trade Size 1/ 2" QLK75 QLK50D 1/ 2" Unit Qty. single 50 3/ 4" 25 duplex 25 Cable Fittings Cat. # Wt. Lbs. Per 100 9 For 14 / 4 to 1 0/ 3 For 3/ 8" FMC 11.5 For 10 / 3 to 6 / 3 For 3/ 8" and 1/ 2" FMC 11 For 14 / 4 to 10 / 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 141 • Clamp Type • Clamps • Anti-Short Bushings Armored and Metal Clad Cable Fittings ARMORED CABLE CONNECTORS – MALLEABLE IRON Features: CLAMPS – STEEL Light Gauge • Male hub treads – NPSM Standard Materials: • Mallable Iron • Steel locknut • Stamped steel covers Cat. # Conduit Sizes Rigid Size of Strap Inside Unit Qty. Wt. Lbs. Per 100 1/ 4" .540 .675 500 200 2 2 566 567 Standard Finishes: • Zinc Plated 3/ 8" ANTI-SHORT BUSHINGS Clamp Type 45° Angle – Non-Insulated UL File No. E-19188 or E-19189 Cat. # Cat. # 723 Trade Size Diam. of Opening for Cable Diam. of Bushed Hole 3/ 8" 21/ 32" 17/ 32" Unit Qty. Wt. Lbs. Per 100 50 14 For 2 conductor No.'s 14, 12, 10 3 conductor No.'s 14, 12, 10 4 conductor No.'s 14, 12 Flexible metallic conduit 5/ 16" and 3/ 8" 735 1/ 2" 15/ 16" 737 3/ 4" 11/ 8" 9/ 16" 25 For 2 conductor No. 8 Flexible metallic conduit 1/ 2" 25/ 32" 25 For 2 conductor No.'s 6, 4 3 conductor No.'s 6, 4 Flexible metallic conduit 3/ 4" 18 24 Clamp Type 45° Angle – Insulated Cable Fittings UL File No. E-19188 or E-19189 Cat. # 1723 1735 1737 142 Diam. of Opening for Cable Diam. of Bushed Hole 3/ 8" 21/ 32" 17/ 32" 3/ 4" 11/ 8" 25/ 32" 1/ 2" 15/ 16" 9/ 16" Unit Qty. Wt. Lbs. Per 100 50 25 25 14 17 24 US: 1-866-764-5454 CAN: 1-800-265-0502 Unit Qty. Std. Pkg. ASB 0 5/ 16" 14 – 2, 14 – 3, 12 – 2 100 22,500 ASB 1 3/ 8" 14 – 4, 12 – 3, 6 – 1, 4 – 1 100 18,000 ASB 2 7/ 16" 12 – 4, 10 – 2, 10 – 3, 2 – 1 50 ASB 3 1/ 2" 10 – 4, 8 – 2, 8 – 3, 1 – 1 50 5,250 ASB 4 3/ 4" 8 – 4, 6 – 4, 6 – 3, 6 – 2, 4 – 3, 4 – 2 50 3,000 ASB 5 1" 3 – 1, 2 – 1, 2 – 1 / 0, 1 – 300 MCM 1 – 350 MCM, 1 – 400 MCM, 1 – 450 MCM, 1 – 500 MCM 25 3,125 ASB 6 11/ 4" 4 – 1, 4 – 1 / 0, 4 – 2 / 0, 3 – 1 / 0, 3 – 2 / 0, 3 – 3 / 0, 2 – 2 / 0, 2 – 3 / 0 2 – 4 / 0, 1 – 600 MCM, 1 – 650 MCM, 1 – 700 MCM, 1 – 750 MCM, 1 – 800 MCM, 1 – 900 MCM 10 1,500 ASB 7 11/ 2" 4 – 3 / 0, 4 – 4 / 0, 3 – 4 / 0, 3 – 250 MCM, 3 – 300 MCM, 2 – 250 MCM, 2 – 300 MCM, 2 – 350 MCM, 1 – 1000 MCM 10 1,000 2" to 21/ 2" 4 4 4 3 3 2 2 10 1,000 ASB 8 Trade Size FMC Trade Size Armoured Cable Size – – – – – – – 250 350 450 350 450 400 500 MCM, MCM, MCM, MCM, MCM, MCM, MCM 4 4 4 3 3 2 – – – – – – 300 400 500 400 500 450 Bushings are packed in clear poly bags. Anti-short bushings have a temperature rating of 90°C Copyright© 2007 Cooper Crouse-Hinds MCM, MCM, MCM, MCM, MCM, MCM, 10,000 • Set Screw Type Connectors • Straight, 45° and 90° Flexible Metallic Conduit Fittings ACB Series Connectors FLEXIBLE METALLIC CONDUIT CONNECTORS – STEEL ACB SERIES Applications: • ACB Series Connectors are used to connect armored cable, metal clad cable or flexible metallic conduit to a box or enclosure. Features: • Dual gripping saddle design on the connector safely secures cable or conduit in place and prevents loosening from vibration. • Insulated throat provides a smooth pulling surface that won't strip cable. • Angled teeth on locknut bite into enclosure, preventing loosening from vibration. • Tri-head set screw may be installed using a slotted, Phillips or Robertson head Screwdriver. • Steel connector is zinc electroplated for corrosion resistance. 45° Connectors* Cable Opening Certifications and Compliances: • UL Listed • cUL Listed Cat. # ACB3845 ACB5045 ACB7545 Materials and Finishes: • • • • Body: Steel – Zinc electroplated Saddle: Steel – Zinc electroplated Screw: Steel – Zinc electroplated Insulated throat: Thermoplastic – Natural Trade Size 3/ 8" 1/ 2" 3/ 4" Max. Min. 0.656 0.437 0.937 0.750 1.125 0.906 Dimensions Unit Qty. Std. Pkg. 50 25 10 200 100 50 Unit Qty. Std. Pkg. A 50 25 10 5 200 100 50 25 13/ 4" 21/ 8" 21/ 2" 213/ 16" A B C 113/ 16" 113/ 16" 15/ 16" 21/ 8" 21/ 8" 11/ 4" 23/ 8" 23/ 8" 17/ 16" *45° not available in 1" size 90° Connectors Straight Connectors Cable Opening Cat. # Cable Opening Cat. # 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Dimensions Max. Min. Unit Qty. 0.656 0.937 1.125 1.468 1.500 1.750 2.031 3.062 3.562 4.060 4.560 0.437 0.750 0.906 1.250 1.312 1.562 1.812 2.812 3.312 3.620 4.120 50 25 10 5 5 5 1 1 1 1 1 Std. Pkg. A 200 100 50 25 10 10 5 5 5 1 1 13/ 16" 13/ 8" 13/ 8" 19/ 16" 23/ 16" 27/ 16" 29/ 16" 211/ 16" 213/ 16" 215/ 16" 3" US: 1-866-764-5454 B C 11/ 4" 1/ 2" 11/ 4" 7/ 16" 17/ 16" 7/ 16" 113/ 16" 1/ 2" 21/ 8" 5/ 8" 21/ 2" 5/ 8" 5/ 8" 3" 35/ 8" 13/ 16" 41/ 4" 15/ 16" 1" 33/ 4" 53/ 16" 11/ 16" CAN: 1-800-265-0502 3/ 8" 1/ 2" 3/ 4" 1" Max. Min. 0.656 0.937 1.125 1.468 Copyright© 2007 Cooper Crouse-Hinds 0.437 0.750 0.906 1.250 Dimensions B C 21/ 16" 1" 21/ 4" 11/ 4" 21/ 2" 13/ 8" 27/ 8" 111/ 16" 143 Cable Fittings ACB38 ACB50 ACB75 ACB100 ACB125 ACB150 ACB200 ACB250 ACB300 ACB350 ACB400 Trade Size ACB3890 ACB5090 ACB7590 ACB10090 Trade Size • Compression Type Couplings • Set Screw Type Couplings • Spacesaver ACB Flexible Metallic Conduit Fittings FLEXIBLE METALLIC CONDUIT COUPLINGS – STEEL ACC SERIES Applications: FLEXIBLE METALLIC CONDUIT, CONNECTORS – STEEL SPACE SAVER ACB SERIES Features: • ACC combination couplings are used to join EMT conduit to armored cable, metal clad cable or flexible metallic conduit. • Male threads on locknut allow for more room inside the box • Smooth pulling surface eliminates the need for insulated throat fittings and/or conduit bushings • Angled teeth on locknut bite into enclosure, preventing loosening from vibration • Dual gripping saddle design on the fitting safely secures cable or conduit in place and prevents loosening from vibration • Tri-head set screw may be installed using a slotted, Philips, or Robertson head screwdriver • Steel fitting is zinc electroplated for corrosion resistance • Suitable for use with steel or aluminum cables Features: • Dual gripping saddle design on the coupling safely secures cable or conduit in place and prevents loosening from vibration • Steel compression ring & nut provide a strong, secure termination point for EMT conduit. • Tri-head set screw may be installed using a slotted, Phillips or Robertson head screwdriver. • Steel combination coupling is zinc electroplated for corrosion resistance. Materials and Finishes: • Body: Steel – Zinc electroplated • Saddle: Steel – Zinc electroplated • Screw: Steel – Zinc electroplated Certifications and Compliances: Certifications and Compliances: • UL Listed • cUL Listed • UL Listed • cUL Listed Compression Coupling: UL File No. E-22132 Cable Opening Cat. # ACC38 ACC50 ACC75 Trade Size 3/ 8" 1/ 2" 3/ 4" Max. Min. Unit Qty. 0.656 0.937 1.125 0.437 0.750 0.906 25 10 10 Cable Fittings Set-Screw Coupling: Cat. # ACCSS38* ACCSS50 ACCSS75 Cable Opening Cat. # Trade Size Unit Qty. Wt. Lbs. Per 100 3/ 8" 25 10 10 9 12 14 1/ 2" 3/ 4" SSACB38 SSACB50 SSACB75 SSACB100 Trade Size KO Size Max. Min. 3/ 8" 1/ 2" 3/ 4" 3/ 4" 1/ 2" 1" 1/ 2" 1" 0.640 0.930 1.125 1.405 *not UL Listed 144 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 0.280 0.635 0.810 0.775 Dimensions Unit Qty. Wt. Lbs. Per 100 50 25 10 5 9 12 14 30 A B 13/ 8" 3/ 4" 13/ 8" 11/ 16" 11/ 2" 11/ 4" 2" 19/ 16" • Set Screw • Quik-Lok • Duplex Flexible Metallic Conduit Fittings FLEXIBLE METALLIC CONDUIT CONNECTORS – MALLEABLE IRON FLEXIBLE METALLIC CONDUIT CONNECTORS – MALLEABLE IRON Set Screw Type Duplex Type UL File No. E-19188 UL File No. E-19188 Trade Size Cat. # 702V Diam. of Opening for Cable 3/ 8" 5/ 8" Diam. of Bushed Hole Unit Qty. Wt. Lbs. Per 100 7/ 16" 100 For 2 conductor No.'s 14, 12 3 conductor No.'s 14, 12 4 conductor No. 14, 5/ 16" flex 7 Trade Size Diam. of Opening for Cable Diam. of Bushed Hole Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 5/ 8" 9/ 16" 25 100 20 90 Degree 3/ 8" 700* 5/ 8" 9/ 16" 25 100 14 Cat. # Straight 699* *UL Listed as grounding means. QUICK-LOK® CONNECTORS FOR FMC – STEEL Features: • No Locknut required • Single-unit or duplex construction with captive clamp • Connects 50 MC, AC, and Flex RW cable sizes with just three fittings • Easy to install: tilt, insert and snap down • Single unit construction eliminates loose component parts, integral green plastic insulated throat bushing provides maximum protection for wire installation • Concrete tight when taped FLEXIBLE METALLIC CONDUIT CONNECTORS – ZINC DIE CAST Duplex Type UL File No. E-19188 Cat. # Trade Size Diam. of Opening for Cable Diam. of Bushed Hole Unit Qty. Std. Pkg. Wt. Lbs. Per 100 2699* 3/ 8" 5/ 8" 9/ 16" 25 250 13 *UL Listed as grounding means. Standard Materials: • Tubular Steel Standard Finishes: • Zinc plated UL File No. E-19188 QLK50S Trade Size 1/ 2" QLK75 QLK50D 1/ 2" Unit Qty. single 50 3/ 4" 25 duplex 25 Cable Fittings Cat. # Wt. Lbs. Per 100 9 For 14 / 4 to 10 / 3 For 3/ 8" FMC 11.5 For 10 / 3 to 6 / 3 For 3/ 8" and 1/ 2" FMC 11 For 14 / 4 to 10 / 3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 145 • Squeeze Type Connectors Flexible Metallic Conduit Fittings FLEXIBLE METALLIC CONDUIT CONNECTORS – MALLEABLE IRON Standard Materials: FLEXIBLE METALLIC CONDUIT CONNECTORS – ZINC DIE CAST • Malleable Iron • Steel Locknut UL File No. E-19188 Squeeze Type* – Straight – Insulated Standard Finishes: • Zinc plated Squeeze Type* Cat. # UL File No. E-19189 Cat. # 707† 708‡ 709 710 711 712 713 714 715 721 722 Trade Size 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Diam. of Opening. for Cable Diam. of Bushed Hole 5/ 8" 15/ 16" 3/ 8" 11/ 8" 13/ 8" 121/ 32" 17/ 8" 21/ 2" 27/ 8" 39/ 16" 4" 419/ 32" 5/ 8" 3/ 4" 1" 15/ 16" 11/ 2" 2" 23/ 8" 3" 213/ 32" 331/ 32" Unit Qty. Wt. Lbs. Per 100 100 50 20 20 10 5 2 2 1 1 1 7 14 22 31 46 79 101 161 220 470 610 *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). †Suitable for use with armored cable. ‡Suitable for use with metal clad cable. Straight – Insulated* Cable Fittings UL File No. E-19189 Cat. # 1707† 1708‡ 1709 1710 1711 1712 1713 1714 1715 1721 1722 Trade Size Diam. of Opening for Cable Diam. of Bushed Hole 3/ 8" 5/ 8" 3/ 8" 11/ 8" 13/ 8" 121/ 32" 17/ 8" 21/ 2" 27/ 8" 39/ 16" 4" 419/ 32" 3/ 4" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 15/ 16" 5/ 8" 1" 15/ 16" 11/ 2" 2" 23/ 8" 3" 313/ 32" 331/ 32" Unit Qty. Wt. Lbs. Per 100 100 50 20 20 10 5 2 2 1 1 1 8 14 17 26 42 77 100 160 221 470 610 1707DC 1708DC 1709DC 1710DC 1711DC 1712DC 1713DC 1714DC 1715DC 1721DC 1722DC Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 50 25 25 10 10 5 4 2 1 1 1 500 250 250 100 100 50 40 10 5 1 1 6 8 11 16 21 28 36 85 109 144 183 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). Squeeze Type* – Straight – Non-Insulated Cat. # 707DC 708DC 709DC 710DC 711DC 712DC 713DC 714DC 715DC 721DC 722DC Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 50 25 25 10 10 5 4 2 1 1 1 500 250 250 100 100 50 40 10 5 1 1 6 8 11 16 21 28 36 85 109 144 183 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). †Suitable for use with armored cable. ‡Suitable for use with metal clad cable. 146 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds • Clamp Type 45° and 90° Connectors Flexible Metallic Conduit Fittings FLEXIBLE METALLIC CONDUIT CONNECTORS – MALLEABLE IRON Features: FLEXIBLE METALLIC CONDUIT CONNECTORS – MALLEABLE IRON Clamp Type* 90° Angle – Non-Insulated UL File No. E-19188 or E-19189 • Male hub treads – NPSM Standard Materials: • Mallable Iron • Steel locknut • Stamped steel covers Standard Finishes: Trade Size Diam. of Opening for Cable 724† 3/ 8" 21/ 32" 736† 738† 739 740 741 742 744 745 746 747 1/ 2" Cat. # • Zinc Plated Clamp Type 45° Angle – Non-Insulated UL File No. E-19188 or E-19189 Cat. # 723 Trade Size Diam. of Opening for Cable 3/ 8" 21/ 32" Diam. of Bushed Hole Unit Qty. Wt. Lbs. Per 100 17/ 32" 50 14 For 2 conductor No.'s 14, 12, 10 3 conductor No.'s 14, 12, 10 4 conductor No.'s 14, 12 Flexible metallic conduit 5/ 16" and 3/ 8" 735 1/ 2" 15/ 16" 737 3/ 4" 11/ 8" 9/ 16" 25 For 2 conductor No. 8 Flexible metallic conduit 1/ 2" 25/ 32" 25 For 2 conductor No.'s 6, 4 3 conductor No.'s 6, 4 Flexible metallic conduit 3/ 4" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 24 UL File No. E-19188 or E-19189 1723 1735 1737 3/ 8" 21/ 32" 17/ 32" 3/ 4" 11/ 8" 25/ 32" 1/ 2" 15/ 16" 9/ 16" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 25 200 100 100 14 17 24 1736† 1738† 1739 1740 1741 1742 1744 1745 1746 1747 Trade Size Diam. of Opening for Cable Diam. of Bushed Hole 1/ 2" 15/ 16" 9/ 16" 13/ 16" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 11/ 8" 113/ 32" 121/ 32" 17/ 8" 21/ 2" 3" 31/ 2" 4" 419/ 32" 1" 11/ 4" 11/ 2" 115/ 16" 21/ 2" 3" 313/ 32" 331/ 32" Unit Qty. Std. Pkg. Wt. Lbs. /100 25 20 5 2 1 1 1 1 1 1 100 100 25 10 10 5 1 1 1 1 19 31 50 113 188 236 400 600 1150 1460 Cable Fittings Cat. # 17/ 32" 50 15 For 2 conductor No.'s 14, 12, 10 3 conductor No.'s 14, 12, 10 4 conductor No.'s 14, 12 Flexible metallic conduit 5/ 16" and 3/ 8" 15/ 16" 9/ 16" 25 19 13/ 16" 20 31 11/ 8" 1" 5 50 113/ 32" 2 113 121/ 32" 11/ 4" 1 188 17/ 8" 11/ 2" 1 236 115/ 16" 21/ 2" 3" 1 400 21/ 2" 3" 1 600 31/ 2" 4" 1 1150 313/ 32" 1 1460 419/ 32" 331/ 32" Clamp Type 90° Angle – Insulated Cat. # Diam. of Bushed Hole Wt. Lbs. /100 18 UL File No. E-19188 or E-19189 Diam. of Opening for Cable Unit Qty. *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). †Suitable for use with armored cable. Clamp Type 45° Angle – Insulated Trade Size Diam. of Bushed Hole †Suitable for use with armored cable. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 147 • Squeeze Type 90° • Screw-In Type Connectors • Screw-In Type Couplings Flexible Metallic Conduit Fittings FLEXIBLE METALLIC CONDUIT CONNECTORS – ZINC DIE CAST FLEXIBLE METALLIC CONDUIT FITTINGS – ZINC DIE CAST Squeeze Type* 90° Angle – Non-Insulated Straight Connectors – Non-Insulated Screw-in Type UL File No. 19189 UL File No. E-19189 Cat. # Trade Size 724DC 736DC 738DC 739DC 740DC 741DC 742DC 744DC 745DC 746DC 747DC 3/ 8" 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Unit Qty. 50 25 10 5 10 1 1 1 1 1 1 Std. Pkg. 500 250 100 50 40 5 5 1 1 1 1 Wt. Lbs. Per 100 8 11 15 25 41 117 119 286 405 560 642 *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). Cat. # Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 80 60 35 15 10 6 3 800 600 350 150 100 60 30 5 5 9 13 24 35 52 Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 1/ 2" 40 25 15 10 6 3 400 250 150 100 60 30 4 8 12 21 31 44 770DC 771DC 772DC 773DC 774DC 775DC 776DC 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Couplings Screw-in Type UL File No. 19189 Squeeze Type* 90° Angle – Insulated UL File No. 19189 Cat. # Cable Fittings Cat. # 1724DC 1736DC 1738DC 1739DC 1740DC 1741DC 1742DC 1744DC 1745DC 1746DC 1747DC Trade Size Unit Qty. Std. Pkg. Wt. Lbs. Per 100 3/ 8" 50 25 10 5 10 1 1 1 1 1 1 500 250 100 50 40 5 5 1 1 1 1 8 11 15 25 41 117 119 286 405 560 642 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 791DC 792DC 793DC 794DC 795DC 796DC 3/ 4" 1" 11/ 4" 11/ 2" 2" *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). 148 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds • Combination Couplings • Back to Back • Anti-Short Flexible Metallic Conduit Fittings ANTI-SHORT BUSHINGS COMBINATION COUPLINGS – ZINC DIE CAST EMT (Set Screw) to Flexible Steel (Clamp)* UL File No. E-19189 FMC Trade Size Cat. # Cat. # 780DC Trade Size 1/ 2" to 3/ 8" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 500 8 *UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b). "BACK TO BACK" BOX CONNECTOR – ZINC DIE CAST Cat. # 5050 Size Unit Qty. Wt. Lbs. Per 100 1/ 2" 25 8 Armoured Cable Size Unit Qty. Std. Pkg. ASB 0 5/ 16" 14 – 2, 14 – 3, 12 – 2 100 22,500 ASB 1 3/ 8" 14 – 4, 12 – 3, 6 – 1, 4 – 1 100 18,000 ASB 2 7/ 16" 12 – 4, 10 – 2, 10 – 3, 2 – 1 50 10,000 ASB 3 1/ 2" 10 – 4, 8 – 2, 8 – 3, 1 – 1 50 5,250 ASB 4 3/ 4" 8 – 4, 6 – 4, 6 – 3, 6 – 2, 4 – 3, 4–2 50 3,000 ASB 5 1" 3 – 1, 2 – 1, 2 – 1 / 0, 1 – 300 MCM 1 – 350 MCM, 1 – 400 MCM, 1 – 450 MCM, 1 – 500 MCM 25 3,125 10 1,500 10 1,000 10 1,000 ASB 6 11/ 4" 4 – 1, 4 – 1 / 0, 4 – 2 / 0, 3 – 1 / 0, 3 – 2 / 0, 3 – 3 / 0, 2 – 2 / 0, 2–3/0 2 – 4 / 0, 1 – 600 MCM, 1 – 650 MCM, 1 – 700 MCM, 1 – 750 MCM, 1 – 800 MCM, 1 – 900 MCM ASB 7 11/ 2" 4 – 3 / 0, 4 – 4 / 0, 3 – 4 / 0, 3 – 250 MCM, 3 – 300 MCM, 2 – 250 MCM, 2 – 300 MCM, 2 – 350 MCM, 1 – 1000 MCM 4 4 4 ASB 8 2" to 21/ 2" 3 3 2 2 Note: – – – – – – – 250 350 450 350 450 400 500 MCM, MCM, MCM, MCM, MCM, MCM, MCM 4 4 4 3 3 2 – – – – – – 300 400 500 400 500 450 MCM, MCM, MCM, MCM, MCM, MCM, Bushings are packed in clear poly bags. Anti-short bushings have a temperature rating of 90°C Cable Fittings US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 149 • Clamp Type • Duplex Type Nonmetallic Cable Connectors NONMETALLIC SHEATHED CABLE AND PORTABLE CORD CONNECTORS – STEEL NONMETALLIC CABLE – ZINC DIE CAST Duplex Type UL File No. E-19188 Clamp Type UL File No. E-22132 Clamp Opening K.O. Size Min. Max. 631 3/ 4" 33/ 64" 13/ 16" 13/ 16" 20 14 For 2 conductor No.'s 8, 6 3 conductor No.'s 8, 6 632 1" 3/ 8" 11/ 64" 10 21 11/ 64" For 2 conductor No.'s 8, 6 3 conductor No.'s 8, 6 Cat. # Width Unit Qty. Wt. Lbs. Per 100 Cat. # Trade Size Diam. of Opening for Cable Diam. of Bushed Hole Unit Qty. Std. Pkg. Wt. Lbs. Per 100 2699* 3/ 8" 5/ 8" 9/ 16" 25 250 13 *UL Listed as grounding means. NONMETALLIC SHEATHED CABLE CONNECTORS – ZINC DIE CAST Cable Fittings UL File No. E-10438 Cat. # Trade Size K.O. Size 759DC 3/ 8" 1/ 2" 100 1000 4 For 2 conductor No.'s 14, 12, 10 3 conductor No.'s 14, 12 2631 3/ 4" 3/ 4" 50 500 9 For 3 conductor No.'s 8, 6 2632 1" 1" 25 250 12 For 3 conductor No.'s 6, 4 2633 11/ 4" 11/ 4" 10 100 22 For 3 conductor No.'s 3, 2 2670 11/ 2" 11/ 2" 5 50 25 For 3 conductor No. 2 / 0 2671 2" 2" 10 40 40 For 3 conductor No. 4 / 0 150 Unit Qty. Std. Pkg. US: 1-866-764-5454 Wt. Lbs. Per 100 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds • Service Entrance Elbows – Aluminum • Entrance Caps Service Entrance and Grounding Fittings SERVICE ENTRANCE FITTINGS SERVICE ENTRANCE FITTINGS Applications: Service Entrance Elbows – Aluminum Gasketed • Use in overhead service entrance • Mounts on top of EMT, Rigid or IMC conduit • Serves as a connecting point for service entrance wires • Available in Clamp Type, Set-Screw, Threaded and Mast Type styles UL File No. E-19189 Cat. # Size SLB1 SLB2 SLB3 SLB4 SLB5 SLB6 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 10 10 5 2 1 1 50 50 25 10 5 5 25 30 51 83 117 192 UL File No. E-153721 Std. Pkg. Wt. Lbs. Per 100 15 10 7 5 3 8 3 3 2 2 90 60 42 30 18 8 3 2 2 2 11 21 27 32 53 89 300 322 513 519 15 10 7 5 3 8 3 3 2 2 90 60 42 30 18 8 3 2 2 2 19 24 24 28 51 81 272 298 538 541 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 15 10 7 5 3 8 3 3 2 2 90 60 42 30 18 8 3 2 2 2 15 18 24 28 58 86 308 308 517 517 11/ 4" – 2" 11/ 4" – 2" 11/ 2" – 21/ 2" 2" – 21/ 2" 2 1 2 1 12 10 12 6 45 75 73 75 Size Clamp Type EHC1 EHC2 EHC3 EHC4 EHC5 EHC6 EHC7 EHC8 EHC9 EHC10 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Threaded Type EHT1 EHT2 EHT3 EHT4 EHT5 EHT6 EHT7 EHT8 EHT9 EHT10 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Set Screw Type EHSS1 EHSS2 EHSS3 EHSS4 EHSS5 EHSS6 EHSS7 EHSS8 EHSS9 EHSS10 Mast Type EHMT1 EHMT2 EHMT3 EHMT4 US: 1-866-764-5454 CAN: 1-800-265-0502 1/ 2" 3/ 4" Copyright© 2007 Cooper Crouse-Hinds Service Entrance/Grounding Unit Qty. Cat. # 151 • • • • Service Entrance and Grounding Fittings Service Entrance Cable Connectors Perforated Strap Ground Straps Ground Clamp Service Entrance Cable Connectors – Malleable Iron Non-watertight for Oval Cable PERFORATED STRAP – STEEL 10 Foot Coils UL File No. E-22134 Cat. # Description Clamp Opening Width Cat. # K.O. Size Min. Max. 3/ 4" 33/ 64" 13/ 16" 1" 3/ 8" 631 632 3000 Std. Pkg. Wt. Lbs. Per 100 200 14 For 2 conductor No.'s 8, 6 3 conductor No.'s 8, 6 3/ 4 × .035 Galvanized holes – 1/ 2" to 1" Centers 1/ 4" Cat. # 141DC Grounding Conductor Electrode Clamping Range 1/ 2", 3/ 4", 1" Lug Conductor Range Unit Qty. Std. Pkg. Wt. Lbs. Per 100 #8 – #2 25 300 16 Clamp Opening Cat. # K.O. Size Min. Max. Width .075" .920" .960" 1.00" 1.30" .075" .920" .960" 1.00" 1.30" Unit Qty. Std. Pkg. Wt. Lbs. Per 100 50 25 10 5 10 500 250 100 50 40 9 12 22 25 40 Service Entrance/Grounding .300" .350" .335" .350" .700" 152 10 100 21 11/ 64" For 2 conductor No.'s 8, 6 3 conductor No.'s 8, 6 UL File No. E-10438 1" 11/ 4" 11/ 2" 2" 10 For Bare or Insulated Wire or Armored Grounding Cable Non-watertight for Oval Cable 3/ 4" Wt. Lbs. Per 100 GROUND CLAMP – ZINC DIE CAST Service Entrance Cable Connectors – Zinc Die Cast 2631 2632 2633 2670 2671 Unit Qty. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Cable Fittings Reference Chart Cat. # AC MC FMC FLEX to EMT AC/ FLEX to EMT Armored Cables Steel & Aluminum Metal Clad Cables Steel & Aluminum AC 0.470min / 12/4max FE & AL MCI 0.470min / 0.500max FE 14/2, 14/3, 14/4, 12/2, 12/3,12/4 .470/.560 ST: 14/2, 14/3, 14/4, 12/2, .470/.500 FE RWFMC 12/4 AL: 14/4 ST: 12/3 FE RWFMC Cable Ranges NM SE 631 • • For 2 conductor No.'s 8, 6 3 conductor No.'s 8, 6 632 • • For 2 conductor No.'s 8, 6 3 conductor No.'s 8, 6 699 • • • 700 • • • 707 • • • AC 0.560, MCI 0.500 FE & AL • MCI 0.870 AL 708 • AL: 6/3 Conduit Cable Type FE RWFMC 709 • FE RWFMC 710 • FE RWFMC 711 • FE RWFMC 712 • FE RWFMC 713 • FE RWFMC 714 • FE RWFMC 715 • FE RWFMC 721 • FE RWFMC 722 • 723 724 • • • • FE RWFMC AC 0.470min / 12/4max FE & AL MCI 0.470min / 0.640max FE MCI 0.500min / 0.630max AL • AC 0.460min / 12/4max FE & AL MCI 0.500min / 0.630max FE MCI 0.500min / 0.640max AL • • 736 • FE RWFMC 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, .460/.550 AL: 14/4, 12/2, 12/3, 12/4, 10/2, 10/3, 10/4, 8/2, .500/.630 ST: 12/3, 12/4, 10/2, 10/3, 10/4, 8/2, .500/.630 FE RWFMC FE RWFMC Cable Fittings 735 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, .470/.550 AL: 14/4, 12/2, 12/3, 12/4, 10/2, 10/3, 10/4, 8/2, .500/.630 ST: 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, 10/3, 10/4, 8/2, .470/.630 FE RWFMC 737 • • • AC 0.990 FE & AL MCI 0.950min /1.020max FE & AL 738 • • • AC 0.920min / 4/3max FE & AL MCI 0.840 FE MCI 0.880min / 1.030max AL 4/3 6/4, 4/3 .950/1.020 FE RWFMC 6/4, 4/3, .920/1.100 AL: 6/3, 6/4, 4/3, .880/1.030 ST: 6/3 FE RWFMC 739 • FE RWFMC 740 • FE RWFMC 741 • FE RWFMC 742 • FE RWFMC 744 • FE RWFMC 745 • FE RWFMC 746 • FE RWFMC 747 • FE RWFMC AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 153 Cable Fittings Reference Chart Armored Cables Steel & Aluminum Cable Ranges AC MC FMC 1707 • • • AC 0.560, MCI 0.500 FE & AL • • MCI 0.870 AL Metal Clad Cables Steel & Aluminum Conduit Cable Type AL: 6/3 FE RWFMC FE RWFMC 1709 • FE RWFMC 1710 • FE RWFMC 1711 • FE RWFMC 1712 • FE RWFMC 1713 • FE RWFMC 1714 • FE RWFMC 1715 • FE RWFMC 1721 • FE RWFMC 1722 • 1723 • 1735 • 1736 • 1737 1738 Cable Fittings SE AC/ FLEX to EMT Cat. # 1708 NM FLEX to EMT • • • • FE RWFMC AC 0.470min / 12/4max FE & AL MCI 0.470mon / 0.640max FE MCI 0.500min / 0.630max AL 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, .470/.550 AL: 14/4, 12/2, 12/3, 12/4, 10/2, 10/3, 10/4, 8/2, .500/.630 ST: 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, 10/3, 10/4, 8/2, .470/.630 FE RWFMC FE RWFMC FE RWFMC • AC 0.990 FE & AL MCI 0.950min /1.020max FE & AL • AC 0.920min / 4/3max FE & AL MCI 0.840 FE MCI 0.880min / 1.030max AL 4/3 6/4, 4/3, .950/1.020 FE RWFMC 6/4, 4/3, .920/1.100 AL: 6/3, 6/4, 4/3, .880/1.030 ST: 6/3 FE RWFMC 1739 • FE RWFMC 1740 • FE RWFMC 1741 • FE RWFMC 1742 • FE RWFMC 1744 • FE RWFMC 1745 • FE RWFMC 1746 • FE RWFMC 1747 • FE RWFMC 2631 • • For 3 conductor No.'s 8, 6 2632 • • For 3 conductor No.'s 6, 4 2633 • • For 3 conductor No.'s 3, 2 2670 • • For 3 conductor No. 2/0 2671 • • For 3 conductor No. 4/0 2699 • • • 1707DC • 1708DC • 1709DC • 1710DC • 1711DC • 1712DC • 1713DC • 1714DC • 1715DC • 1721DC • 1722DC • 1724DC • 1736DC • 1738DC • AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit 154 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Cable Fittings Reference Chart Cat. # AC MC FMC 1739DC • 1740DC • 1741DC • 1742DC • 1744DC • 1745DC • 1746DC • 1747DC 702V SE AC/ FLEX to EMT Cable Ranges Armored Cables Steel & Aluminum Metal Clad Cables Steel & Aluminum Conduit Cable Type • • • • 707DC • 708DC • 709DC • 710DC • 711DC • 712DC • 713DC • 714DC • 715DC • 721DC • 722DC • 724DC • 736DC • 738DC • 739DC • 740DC • 741DC • 742DC • 744DC • 745DC • 746DC • 747DC • 759DC For 2 conductor No.s 14, 12, 10 3 conductor No.'s 14, 12 • • 771DC • 772DC • 773DC • 774DC • 775DC • 776DC • 780DC Cable Fittings 770DC 791DC NM FLEX to EMT • • 792DC • 793DC • 794DC • 795DC • 796DC • AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 155 Cable Fittings Reference Chart Cat. # MC FMC NM SE AC/ FLEX to EMT Cable Ranges AC 0.930min / 1/4max FE & AL MCI 0.960min / 1.468max FE & AL Armored Cables Steel & Aluminum Metal Clad Cables Steel & Aluminum 6/4, 4/3, 4/4, 3/2, 3/3, 2/3, 2/4, 1/3, 1/4, .930/1.468 6/4, 4/3, 4/4, 3/3, 3/4, .960/1.468 Conduit Cable Type FEFMC ACB100 • • • ACB125 • • • FEFMC ACB150 • • • FEFMC ACB200 • • • FEFMC ACB250 • • • FEFMC ACB300 • • • FEFMC ACB350 • • • AC 0.450min / 10/2max FE & AL MCI 0.450min / 0.660max FE & AL 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 FEFMC • AC 0.550min / 6/3max FE & AL MCI 0.640min / 0.920max FE & AL 12/4, 10/2, 10/3, 10/4, 8/2, 8/3, 8/4, 6/2, 6/3, .550/.920 10/2, 10/3, 10/4, 8/2, 8/3, .640/.920 FEFMC • AC 0.930min / 4/3max FE AC 0.680min / 4/3max AL MCI 0.730min / 1.075max FE MCI 0.930min / 1.075max AL AL: 8/3, 8/4, 6/2, 6/3, 6/4, 4/2, 4/3, .680/1.075 ST: 6/4, 4/2, 4/3, .930/1.075 AL: 6/4, 4/3, 3/3, .930/1.075 ST: 8/3, 8/4, 6/2, 6/3, 6/4, 4/3, 3/3, .730/1.075 FEFMC • • • ACB400 • • • ACB75 • • • • FEFMC 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 ACB38 ACB50 Cable Fittings AC FLEX to EMT ACC38 • • ACC50 • • ACC75 • • ACCSS38 • • ACCSS50 • • ACCSS75 • • ASB 0 • • ASB 1 • • 14/2, 14/3, 12/2 14/4, 12/3, 6/1, 4/1 ASB 2 • • 12/2, 10/2, 10/3, 2/1 ASB 3 • • 10/4, 8/2, 8/3, 1/1 ASB 4 • • 8/4, 6/4, 6/3, 6/2, 4/3, 4/2 ASB 5 • • 3/1, 2/1, 2-1/0, 1-300 MCM, 1-350 MCM, 1-400 MCM, 1-450 MCM, 1-500 MCM ASB 6 • • 4/1, 4-1/0, 4-2/0, 3-1/0, 3-2/0, 3-3/0, 2-2/0, 2-3/0, 2-4/0, 1-600 MCM, 1-650 MCM, 1-700 MCM, 1-750 MCM, 1-800 MCM, 1-900 MCM, ASB 7 • • 4-3/0, 4-4/0, 3-4/0, 3-250 MCM, 3-300 MCM, 2-250MCM, 2-300 MCM, 2-350 MCM, 1-1000 MCM ASB 8 • • 4-250 4-400 3-350 3-500 2-500 MCM, MCM, MCM, MCM, MCM 4-300 4-450 3-400 2-400 MCM, MCM, MCM, MCM, 4-350 4-500 3-450 2-450 MCM, MCM, MCM, MCM, AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit 156 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Cable Fittings Reference Chart NM SE FLEX to EMT AC/ FLEX to EMT Cable Ranges Armored Cables Steel & Aluminum Metal Clad Cables Steel & Aluminum Conduit Cable Type Cat. # AC MC FMC QLK50D • • • 14/2, 14/3, 14/4, 12/2, 12/3, 12/4 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2 QLK50S • • • 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, 10/3 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2 QLK75 • • • 10/4, 10/5, 8/3, 8/4, 6/3 10/3, 10/4, 8/2, 8/3, 6/2, SSACB38 • • • AC 0.450min / 10/2max FE & AL MCI 0.450min / 0.660max FE & AL 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 .450/.660 FEFMC SSACB50 • • • AC 0.550min / 6/3max FE & AL MCI 0.640min / 0920max FE & AL 12/4, 10/2, 10/3, 10/4, 8/2, 8/3, 8/4, 6/2, 6/3, .550/.920 .640/3920 FEFMC SSACB75 • • • AC 0.930min / 4/3max FE AC 0.680min / 4/3max AL MCI 0.730min / 1.075max FE MCI 0.930min / 1.075max AL 8/3, 8/4, 6/2, 6/3, 6/4, 4/2, 4/3, .930/1.075 AL: .930/1.075 ST: .730/1.075 FEFMC SSACB100 • • • AC 0.930min / 1/4max FE & AL MCI 0.960min / 1.468max FE & AL 6/4, 4/3, 4/4, 3/3, 3/4, 2/3, 2/4, 1/3, 1/4, .930/1.468 .960/1.468 FEFMC ACB3845 • • • AC 0.450min / 10/2max FE & AL MCI 0.450min / 0.660max FE & AL 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 FEFMC ACB5045 • • • AC 0.550min / 6/3max FE & AL MCI 0.640min / 0.920max FE & AL 12/4, 10/2, 10/3, 10/4, 8/2, 8/3, 8/4, 6/2, 6/3, .550/.920 10/2, 10/3, 10/4, 8/2, 8/3, .640/.920 FEFMC AL: 8/3, 8/4, 6/2, 6/3, 6/4, 4/2, 4/3, .680/1.075 ST: 6/4, 4/2, 4/3, .930/1.075 AL: 6/4, 4/3, 3/3, .930/1.075 ST: 8/3, 8/4, 6/2, 6/3, 6/4, 4/3, 3/3, .730/1.075 FEFMC • • • ACB3890 • • • AC 0.450min / 10/2max FE & AL MCI 0.450min / 0.660max FE & AL 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 14/2, 14/3, 14/4, 12/2, 12/3, 12/4, 10/2, .450/.660 FEFMC ACB5090 • • • AC 0.550min / 6/3max FE & AL MCI 0.640min / 0.920max FE & AL 12/4, 10/2, 10/3, 10/4, 8/2, 8/3, 8/4, 6/2, 6/3, .550/.920 10/2, 10/3, 10/4, 8/2, 8/3, .640/.920 FEFMC AL: 8/3, 8/4, 6/2, 6/3, 6/4, 4/2, 4/3, .680/1.075 ST: 6/4, 4/2, 4/3, .930/1.075 AL: 6/4, 4/3, 3/3, .930/1.075 ST: 8/3, 8/4, 6/2, 6/3, 6/4, 4/3, 3/3, .730/1.075 FEFMC 6/4, 4/3, 4/4, 3/2, 3/3, 2/3, 2/4, 1/3, 1/4, .930/1.468 6/4, 4/3, 4/4, 3/3, 3/4, .960/1.468 FEFMC ACB7590 • • • AC 0.930min / 4/3max FE AC 0.680min / 4/3max AL MCI 0.730min / 1.075max FE MCI 0.930min / 1.075max AL ACB10090 • • • AC 0.930min / 1/4max FE & AL MCI 0.960min / 1.468max FE & AL Cable Fittings ACB7545 AC 0.930min / 4/3max FE AC 0.680min / 4/3max AL MCI 0.730min / 1.075max FE MCI 0.930min / 1.075max AL AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 157 Junction Boxes Application and Selection Applications: Junction boxes, designed for hazardous and non-hazardous locations, are used in a variety of industries to perform the following functions: • As a pull box • To provide enclosures for splices and taps • As a mounting box for multi-device control stations • For housing apparatus, instruments, and other devices Considerations for Selection: • Number and size of conductors – combined with the function to be performed (i.e., splicing, pull box), determines the amount of space needed, and therefore, the required physical dimensions of the box. • Conduit layout – determines the number, size, and location of the conduit openings in the box. It will also determine the type of mounting required (i.e., flush or surface positioning of the box). • Flexibility required – if changes in the electrical system are anticipated, the box chosen should be easily adaptable, either by construction (i.e., detachable hub plates) or size to the future system. • Environmental location – the physical location of the junction box will call for proper construction of the box to meet National Electrical Code requirements and will affect the material and finish needed to meet weather and corrosive conditions, if present. Options and Accessories: A wide variety of options and accessories for special application are available for the various junction box families. These can be selected once the type of junction box has been determined. These options are shown on the individual pages. Some of the options available include: • Special covers • Hinged covers • Materials and finishes • Equipment mounting plates • Openings for control station and other device mounting • Corro-free™ epoxy powder coat – information available on request Quick Selector Chart Max. Conduit Opening Size Mtg. 4 × 4 × 2 to 24 × 24 × 8 5 Surface Raintight/Type 3, Watertight/Type 4, Dust-tight/Type 12 4 × 4 × 2 to 24 × 24 × 8 5 WJB Raintight/Type 3, Watertight/Type 4 4 × 4 × 3 to 36 × 24 × 24 WJBF Raintight/Type 3, Watertight/Type 4 WEB Raintight/Type 3 Environmental Capability/Type Designation Size Range† L, W, D Inside WAB Raintight/Type 3, Dust-tight/Type 12 WCB Junction Boxes Type of Conduit Opening Cover Type Page No. Drilled and tapped, slip holes Unflanged [1497] Surface Drilled and tapped, slip holes Overlapping [1746] 6 Surface Drilled and tapped, slip holes Flanged [1747] 4 × 4 × 4 to 36 × 24 × 24 6 Flush Drilled and tapped, slip holes External flanged recessed sidewalk [1748] 4 × 4 × 3 to 36 × 36 × 12 6 Flush Drilled and tapped, slip holes Internal Flanged [1749] Junction Boxes †Length and width are inside dimensions. Depth is inside dimension without cover. Lightning Service™ Delivery Identification – Looking for junction boxes to meet tight deadlines? Then specify Lightning Service. All products available with Lightning Service delivery will be marked with a checkmark. Look for pages with the Lightning Service Logo located at the top of the page. Lightning Service is available for over 90 of the most popular size boxes in five different styles. Shipped within 24 hours: All enclosures marked with a check mark are available in 24 hours without drilled and tapped openings or a mounting plate. Shipped within 72 hours: All enclosures marked with a check mark are available in 72 hours with standard drilled and tapped openings and/or a mounting plate. In Canada: Enclosures without openings or mountings plate shipped within 1 week. Enclosures with standard openings or mounting plate shipped within 2 weeks 158 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds WAB Junction Boxes Heavy Duty Unflanged for Surface Mounting Dust-proof Weatherproof Applications: Where a heavy duty dustproof or weatherproof enclosure is desired, WAB boxes are installed in conduit system to: • Act as pull box for conductors • Provide openings and space for making splices and taps in conductors • Provide for branch conduit runs • Provide access to conductors for maintenance and future system changes • Enclose and protect electrical devices Features: • Flat neoprene gasket cemented to the cover. • Wide range of drilled and tapped and slip hole conduit entrance sizes and locations permits extreme flexibility of use in conduit system. • Internal equipment mounting pads available blind tapped for 1/ 4" – 20 mounting screws. • Blind tapped into internal mounting pads. • Mounting straps are standard on all boxes. Standard Materials: • • • • • Feraloy iron alloy body Heavy-gauge steel cover Neoprene gaskets Stainless steel cover screws Steel mounting straps ® Standard Finishes: • Feraloy iron alloy and heavy gauge steel – hot dip galvanized Options: Description Factory installed mounting plate Suffix -MP Size Ranges: • 4" × 4" × 2" to 24" × 24"× 8" Wall Thickness (in.) Length (in.) Width (in.) Depth (in.) 5/ 32 4 4 4 5 5 6 6 6 6 6 8 8 8 8 8 8 9 10 10 10 10 12 12 12 12 12 12 12 16 16 18 18 18 18 18 24 24 4 4 4 5 5 4 4 6 6 6 4 6 6 8 8 8 6 6 8 8 10 6 6 8 8 12 12 12 6 12 12 12 12 18 18 12 24 2 3 4 3 4 3 4 3 4 6 3 4 6 4 6 8 4 4 4 6 6 4 6 6 8 4 6 8 6 8 6 8 10 6 12 12 8 WAB040402✓ WAB040403✓ WAB040404✓ WAB050503✓ WAB050504✓ WAB060403✓ WAB060404✓ WAB060603✓ WAB060604✓ WAB060606✓ WAB080403 WAB080604✓ WAB080606✓ WAB080804✓ WAB080806✓ WAB080808✓ WAB090604 WAB100604 WAB100804✓ WAB100806✓ WAB101006✓ WAB120604✓ WAB120606✓ WAB120806✓ WAB120808 WAB121204✓ WAB121206✓ WAB121208✓ WAB160606 WAB161208✓ WAB181206✓ WAB181208 WAB181210 WAB181806✓ WAB181812✓ WAB241212 WAB242408 3/ 16 1/ 4 1/ 4 1/ 4 1/ 4 7/ 32 1/ 4 3/ 16 9/ 32 5/ 16 7/ 32 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 1/ 4 1/ 4 9/ 32 1/ 4 9/ 32 9/ 32 9/ 32 3/ 8 9/ 32 9/ 32 9/ 32 1/ 4 5/ 16 5/ 16 5/ 16 3/ 8 3/ 8 7/ 16 7/ 16 11/ 32 Junction Boxes See Ordering Information, beginning pg. 164, for: Drilled and tapped conduit holes Slip holes Cat. # ✓ – available with Lightning Service™ Certifications and Compliances: • • • • UL Standard: 50 Dust-proof Weatherproof H20 Vehicle Load Rating* *Self certify to H20 vehicle load rating equivalent to 16,000 lbs. on cover center. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 159 Dust-tight Weatherproof Watertight Raintight WCB Junction Boxes Heavy Duty Overlapping Cover for Surface Mounting Applications: Where a heavy duty dust-tight, weatherproof, raintight, or watertight enclosure is desired, WCB boxes are installed in conduit systems to: • Act as pull box for conductors • Provide openings and space for making splices and taps in conductors • Provide for branch conduit runs • Provide access to conductors for maintenance and future system changes • Enclose and protect electrical devices Features: • Flat neoprene gasket cemented to cover. • Overlapping cover sheds environment. • Wide range of drilled and tapped and slip hole conduit entrance sizes and locations permits maximum flexibility of use in conduit system. • Internal equipment mounting pads available blind tapped for 1/ 4" – 20 mounting screws. • Blind tapped into internal mounting pads. • Mounting straps are standard on all boxes. Standard Materials: • • • • Feraloy iron alloy cover and body Neoprene gaskets Stainless steel cover screws Steel mounting straps ® Standard Finishes: • Feraloy iron alloy – hot dip galvanized Options: Description Factory installed mounting plate Junction Boxes See Ordering Information, beginning pg. 164, for: Drilled and tapped conduit holes Slip holes Size Ranges: • 4" × 4" × 2" to 24" × 24" × 8" Certifications and Compliances: • • • • • Suffix -MP Cat. # Wall Thickness (in.) Length (in.) Width (in.) Depth (in.) 5/ 32 4 4 4 5 5 6 6 6 6 6 8 8 8 8 8 8 9 10 10 10 10 12 12 12 12 12 12 12 16 16 18 18 18 18 18 24 24 4 4 4 5 5 4 4 6 6 6 4 6 6 8 8 8 6 6 8 8 10 6 6 8 8 12 12 12 6 12 12 12 12 18 18 12 24 2 3 4 3 4 3 4 3 4 6 3 4 6 4 6 8 4 4 4 6 6 4 6 6 8 4 6 8 6 8 6 8 10 6 12 12 8 WCB040402 WCB040403✓ WCB040404✓ WCB050503✓ WCB050504✓ WCB060403✓ WCB060404✓ WCB060603✓ WCB060604✓ WCB060606✓ WCB080403 WCB080604✓ WCB080606✓ WCB080804✓ WCB080806✓ WCB080808✓ WCB090604✓ WCB100604 WCB100804✓ WCB100806✓ WCB101006✓ WCB120604✓ WCB120606✓ WCB120806✓ WCB120808 WCB121204✓ WCB121206✓ WCB121208✓ WCB160606 WCB161208✓ WCB181206✓ WCB181208 WCB181210 WCB181806✓ WCB181812✓ WCB241212 WCB242408✓ 3/ 16 1/ 4 1/ 4 1/ 4 1/ 4 7/ 32 1/ 4 3/ 16 9/ 32 5/ 16 7/ 32 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 1/ 4 1/ 4 9/ 32 1/ 4 9/ 32 9/ 32 9/ 32 3/ 8 9/ 32 9/ 32 9/ 32 1/ 4 5/ 16 5/ 16 5/ 16 3/ 8 3/ 8 7/ 16 7/ 16 11/ 32 ✓ – available with Lightning Service™ UL Standard: 50 Dust-tight Weatherproof Raintight Watertight 160 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds WJB Junction Boxes Heavy Duty Flanged for Surface Mounting Weatherproof Watertight Raintight Applications: WJB boxes are standard with mounting straps and are primarily designed for surface mounting. WJB heavy duty junction boxes are installed in conduit systems to: • Act as pull box for conductors • Provide openings and space for making splices and taps in conductors • Provide for branch conduit runs • Provide access to conductors for maintenance and future system changes • Enclose and protect electrical equipment Features: • Neoprene gasket cemented to cover. • Wide range of drilled and tapped conduit entrance sizes and locations permits extreme flexibility of use in conduit system. • Internal equipment mounting pads may be drilled and tapped for 1/ 4" – 20 mounting screws. • Blind tapped into internal mounting pads. Standard Materials: • Feraloy® iron alloy body • Heavy-gauge steel – cover and mounting straps • Neoprene gaskets Standard Finishes: • Feraloy iron alloy and heavy-gauge steel – hot-dip galvanized Options: Description Factory installed mounting plate Suffix -MP See Ordering Information, beginning pg. 164, for: Drilled and tapped conduit holes Slip holes • • • • • UL Standard: 50 CSA Standard C22.2 Weatherproof Watertight CEC: Class II, E, F, G Class III Encl. 3 – 4 • H20 Vehicle Load Rating* *Self certify to H20 vehicle load rating equivalent to 16,000 lbs. on cover center. Size Ranges: • 4" x 4" x 3" to 36" x 24" x 24" Wall Thickness (in.) Length (in.) Width (in.) Depth (in.) 1/ 4 4 4 6 6 6 8 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 14 14 16 16 16 18 18 18 18 18 18 18 18 18 18 18 18 24 24 24 24 24 24 24 24 24 30 30 36 36 4 4 4 6 6 6 6 8 8 8 8 8 10 10 6 8 8 8 12 12 12 12 8 14 12 12 16 8 8 10 12 12 12 12 12 18 18 18 18 12 12 18 18 18 18 24 24 24 24 24 24 24 3 4 4 4 6 4 6 4 6 8 6 8 6 8 6 6 8 10 6 8 12 18 6 10 6 8 6 6 8 6 6 8 10 12 18 6 8 12 18 8 12 8 10 12 18 12 18 24 12 18 18 24 WJB040403 WJB040404✓ WJB060404 WJB060604✓ WJB060606✓ WJB080604 WJB080606✓ WJB080804✓ WJB080806 WJB080808 WJB100806 WJB100808 WJB101006✓ WJB101008 WJB120606 WJB120806 WJB120808 WJB120810 WJB121206✓ WJB121208✓ WJB121212 WJB121218 WJB140806 WJB141410 WJB161206 WJB161208 WJB161606 WJB180806 WJB180808 WJB181006 WJB181206 WJB181208✓ WJB181210 WJB181212 WJB181218 WJB181806 WJB181808 WJB181812 WJB181818 WJB241208 WJB241212 WJB241808 WJB241810 WJB241812 WJB241818 WJB242412 WJB242418 WJB242424 WJB302412 WJB302418 WJB362418 WJB362424 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 5/ 16 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 9/ 16 9/ 16 9/ 16 9/ 16 9/ 16 9/ 16 9/ 16 9/ 16 Junction Boxes Certifications and Compliances: Cat. # ✓ – available with Lightning Service™ US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 161 Weatherproof Watertight Raintight NEMA 3, 4 WJBF Checkered Cover Sidewalk Junction Boxes Heavy Duty External Flanged for Flush Mounting Applications: WJB boxes are standard with mounting straps and are primarily designed for surface mounting. WJB heavy duty junction boxes are installed in conduit systems to: • Act as pull box for conductors • Provide openings and space for making splices and taps in conductors • Provide for branch conduit runs • Provide access to conductors for maintenance and future system changes • Enclose and protect electrical equipment Features: • Covers are suitable for vehicular traffic (H20 loading) • Neoprene gasket cemented to cover • Wide range of drilled and tapped conduit entrance sizes and locations permits extreme flexibility of use in conduit system • Internal equipment mounting pads may be drilled and tapped for 1/ 4" – 20 mounting screws • Blind tapped into internal mounting pads Standard Materials: • Feraloy® iron alloy body • Heavy-guage Steel (checkered) – cover, mounting straps • Neoprene gaskets Standard Finishes: • Feraloy iron alloy and heavy-gauge steel – hot-dip galvanized Options: Description Factory installed mounting plate Suffix -MP Junction Boxes See Ordering Information, beginning pg. 164, for: Drilled and tapped conduit holes Slip holes Size Ranges: • 4" x 4" x 4" to 36" x 24" x 24" Certifications and Compliances: • • • • • UL Standard: 50 CSA Standard C22.2 No. 40 Weatherproof Watertight CEC: Class II, Division 1, Groups E, F, G Class III Encl. 3, 4 • H20 Vehicle Load Rating* *Self certify to H20 vehicle load rating equivalent to 16,000 lbs. on cover center. 162 Cat. # WJBF040404✓ WJBF060404✓ WJBF060604✓ WJBF060606✓ WJBF080604✓ WJBF080606✓ WJBF080804✓ WJBF080806✓ WJBF080808✓ WJBF100806 WJBF100808 WJBF101006✓ WJBF101008✓ WJBF120606 WJBF120806 WJBF120808✓ WJBF120810 WJBF121206✓ WJBF121208✓ WJBF121212✓ WJBF121218 WJBF140806 WJBF141410 WJBF161206 WJBF161208✓ WJBF161606 WJBF180806 WJBF180808 WJBF181006 WJBF181206 WJBF181208✓ WJBF181210 WJBF181212 WJBF181218 WJBF181806 WJBF181808 WJBF181812✓ WJBF181818 WJBF241208 WJBF241212 WJBF241808 WJBF241810✓ WJBF241812 WJBF241818 WJBF242412 WJBF242418 WJBF242424 WJBF302412 WJBF302418 WJBF362418 WJBF362424 Wall Thickness (in.) Length (in.) Width (in.) Depth (in.) 1/ 4 4 6 6 6 8 8 8 8 8 10 10 10 10 12 12 12 12 12 12 12 12 14 14 16 16 16 18 18 18 18 18 18 18 18 18 18 18 18 24 24 24 24 24 24 24 24 24 30 30 36 36 4 4 6 6 6 6 8 8 8 8 8 10 10 6 8 8 8 12 12 12 12 8 14 12 12 16 8 8 10 12 12 12 12 12 18 18 18 18 12 12 18 18 18 18 24 24 24 24 24 24 24 4 4 4 6 4 6 4 6 8 6 8 6 8 6 6 8 10 6 8 12 18 6 10 6 8 6 6 8 6 6 8 10 12 18 6 8 12 18 8 12 8 10 12 18 12 18 24 12 18 18 24 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 5/ 16 1/ 4 1/ 4 5/ 16 5/ 16 1/ 4 5/ 16 1/ 4 1/ 4 1/ 4 1/ 4 1/ 4 5/ 16 5/ 16 5/ 16 3/ 8 5/ 16 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 3/ 8 ✓ – available with Lightning Service™ US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds WEB Junction Box Heavy Duty Internal Recess Flange for Flush Mounting Dust-tight Raintight NEMA 3 Applications: WEB Junction Boxes are installed: • Where a heavy duty, dust-tight or raintight enclosure is desired • To act as pull box for conductors • To provide openings and space for making splices and taps in conductors • To provide for branch conduit runs • To provide access to conductors for maintenance and future system changes • To enclose and protect electrical devices Features: • Flat neoprene gasket cemented to cover • Internal equipment mounting pads • Standard attachable heavy-gauge steel straps for mounting box • Stainless-steel cover screws • Internal ground screw • Optional drilled and tapped conduit entries or slip holes • Optional mounting plate Standard Materials: • Body – Feraloy® iron alloy, hot dip galvanized • Cover – heavy-gauge steel, hot dip galvanized • Cover screws – stainless steel • Mounting Strap – heavy-gauge steel, electrogalvanized • Gasket – neoprene Cat. # WEB040403 WEB040404 WEB060604 WEB060606 WEB080804 WEB080806 WEB121206 WEB160606 WEB160806 WEB180808 WEB240606 WEB240808 WEB241010 WEB241210 WEB241212 WEB241812 WEB361212 WEB361812 WEB362412 WEB363612 Wall Thickness (in.) Length (in.) Width (in.) Depth (in.) 7/ 32 4 4 6 6 8 8 12 16 16 18 24 24 24 24 24 24 36 36 36 36 4 4 6 6 8 8 12 6 8 8 6 8 10 12 12 18 12 18 24 36 3 4 1/ 4 9/ 32 1/ 4 9/ 32 1/ 4 9/ 32 9/ 32 1/ 4 5/ 16 9/ 32 5/ 16 3/ 8 5/ 16 5/ 16 3/ 8 3/ 8 3/ 8 7/ 16 7/ 16 6 4 6 6 6 6 8 6 8 10 10 12 12 12 12 12 12 Certifications and Compliances: • UL Standard 50 • CSA certified C22.2 Options: Description Suffix All boxes are available with optional -MP mounting plate Junction Boxes See Ordering Information, beginning pg. 164, for: Drilled and tapped conduit holes Slip holes US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 163 W Series Junction Boxes Ordering Information DRILLED AND TAPPED CONDUIT OPENINGS OR SLIP HOLES All W-Series cast-iron junction boxes may be ordered with drilled and tapped conduit openings or slip holes – subject to minimum spacing limitations listed in Table 1. To order a box from the factory with conduit openings: Option 1: Table 1 Send in a sketch of the box with openings specified (subject to spacing limitations specified in Table 1). OR Minimum spacing between centers of conduits 1/ 2" Option 2: Step 1: Select one of the four standard arrangements in Table 2, based on number and location of conduit entries. Step 2: Pick a symbol from Table 3 for each opening in the arrangement (see example). Step 3: Table 4 lists the maximum size and number of conduit openings by box size and the spacing dimensions. Use Table 4 to verify the openings selected are permitted. 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" 6" 5" 4" 31/2" 5 51/ 8 51/ 4 51/ 2 55/ 8 6 61/ 4 65/ 8 7 71/ 4 8 85/ 8 43/ 8 35/ 8 33/ 8 41/ 2 45/ 8 47/ 8 5 53/ 8 55/ 8 6 61/ 4 65/ 8 71/ 4 33/ 4 4 41/ 8 41/ 4 45/ 8 47/ 8 53/ 8 55/ 8 57/ 8 31/ 2 35/ 8 37/ 8 4 41/ 4 45/ 8 5 51/ 4 3" 21/2" 2" 3 31/ 8 31/ 4 31/ 2 35/ 8 37/ 8 41/ 4 45/ 8 25/ 8 23/ 8 23/ 4 3 31/ 8 31/ 4 35/ 8 37/ 8 21/ 2 25/ 8 27/ 8 3 31/ 4 11/2" 11/4" 1" 3/ 4" 1/ 2" 2 21/ 8 23/ 8 21/ 2 25/ 8 17/ 8 13/ 4 15/ 8 11/ 2 2 21/ 4 23/ 8 2 17/ 8 13/ 4 Table 2 Example – Catalog number logic: Standard conduit arrangements 1. Select box required: WAB121208. 2. User wants one 1/ 2" drilled and tapped hole in the top of the box, two 1" drilled and tapped holes on both sides and three 1/ 2" slip holes in the bottom of the box. 3. Select arrangement 3 because it allows up to three openings per side. 4. Next the symbols for the openings are substituted and written in clockwise order starting with location "a". The catalog number is written in three parts; part 1 – box number, part 2 – arrangement number, part 3 – symbols for the conduit openings. 5. For this example the box would be ordered as: Junction Boxes Size of Conduit Table 3 Symbols for openings Conduit Size Drilled and Tapped Hole Slip Hole A B C E F G H J K L M N 0 (Zero) 1A 1B 1C 1E 1F 1G 1H 1J 1K 1L 1M 1N 0 (Zero) 1/ 2" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" 5" 6" None S = Dimension from wall to hole center line 164 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds W Series Junction Boxes Ordering Information DRILLED AND TAPPED CONDUIT OPENINGS OR SLIP HOLES Table 4 Maximum Size and Number of Drilled and Tapped Conduit Openings Top and Bottom† Sides W Series Cat. # 040402 040403 040404 050503 050504 Spacing Dimensions* 1 2 3 4 1 2 3 4 s t u v w x y 3/ 4 3/ 4 — — — — — — — — — — 3/ 4 3/ 4 — — — — — — — — — — 11/ 4 15/ 8 21/ 4 15/ 8 21/ 4 7/ 8 7/ 8 7/ 8 11/ 4 11/ 4 7/ 8 11/ 4 11/ 4 — — — — — — — — — — — — — — — — — — — — 7/ 8 — — 13/ 4 13/ 4 13/ 4 — — — — — — — — — — 11/ 4 2 11/ 4 2 3/ 4 3/ 4 3/ 4 1 11/ 4 2 11/ 4 2 3/ 4 3/ 4 3/ 4 1 7/ 8 7/ 8 2 11/ 4 2 4 3/ 4 3/ 4 11/ 4 11/ 2 11/ 2 — — 3/ 4 3/ 4 3/ 4 — — — — — 15/ 8 21/ 4 11/ 4 21/ 4 33/ 8 13/ 8 13/ 8 13/ 8 13/ 8 13/ 8 13/ 8 13/ 8 13/ 8 13/ 4 13/ 4 13/ 4 13/ 4 13/ 4 1 1 1 1 1 3/ 4 11/ 4 2 4 3 4 3/ 4 11/ 2 11/ 2 2 2 — 3/ 4 3/ 4 1 1 — — — 3/ 4 3/ 4 15/ 8 21/ 4 33/ 8 21/ 4 33/ 8 15/ 8 15/ 8 15/ 8 15/ 8 15/ 8 7/ 8 13/ 8 13/ 8 15/ 8 15/ 8 21/ 2 21/ 2 21/ 2 21/ 2 21/ 2 — 13/ 4 13/ 4 21/ 2 21/ 2 — 13/ 4 13/ 4 13/ 4 13/ 4 — — — 13/ 4 13/ 4 2 11/ 4 2 2 3 1 11/ 2 11/ 2 11/ 2 11/ 2 3/ 4 4 2 2 2 4 2 11/ 2 11/ 2 2 2 1 1 1 1 1 3/ 4 — — 3/ 4 2/ 4 41/ 4 21/ 4 21/ 4 21/ 4 33/ 8 15/ 8 21/ 4 21/ 2 21/ 2 21/ 2 15/ 8 13/ 8 13/ 8 15/ 8 15/ 8 21/ 2 3 23/ 4 23/ 4 23/ 4 21/ 2 13/ 4 13/ 4 21/ 2 13/ 4 13/ 4 2 21/ 2 21/ 2 21/ 2 13/ 4 — — 13/ 4 13/ 4 5 4 5 2 4 3 3 3 2 4 11/ 2 11/ 2 11/ 2 2 21/ 2 1 1 1 11/ 2 11/ 2 5 3 5 2 4 2 3 3 11/ 2 11/ 2 1 11/ 2 11/ 2 3/ 4 3/ 4 3/ 4 41/ 2 23/ 8 41/ 4 21/ 4 33/ 8 21/ 2 21/ 2 21/ 2 3 3 15/ 8 21/ 2 21/ 2 13/ 8 13/ 8 23/ 4 23/ 4 23/ 4 4 4 21/ 2 23/ 4 23/ 4 13/ 4 13/ 4 21/ 2 21/ 2 21/ 2 23/ 4 23/ 4 13/ 4 21/ 2 21/ 2 — — 120806 120808 121204 121206 121208 4 5 2 4 5 4 4 2 4 4 21/ 2 21/ 2 2 21/ 2 21/ 2 21/ 2 21/ 2 11/ 2 11/ 2 11/ 2 4 5 2 4 5 2 2 2 4 4 1 1 2 21/ 2 21/ 2 11/ 2 11/ 2 11/ 2 33/ 8 41/ 4 21/ 4 33/ 8 41/ 4 3 3 3 3 3 15/ 8 15/ 8 3 3 3 4 4 4 4 4 21/ 2 21/ 2 4 4 4 23/ 4 23/ 4 23/ 4 23/ 4 23/ 4 13/ 4 11/ 4 23/ 4 23/ 4 23/ 4 121212 121218 140806 141206 141410 6 6 4 4 6 4 4 4 4 4 21/ 2 21/ 2 3 3 3 11/ 2 11/ 2 2 2 2 6 6 4 4 6 4 4 2 4 4 21/ 2 21/ 2 1 21/ 2 3 11/ 2 11/ 2 3/ 4 11/ 2 2 5 5 33/ 8 33/ 8 5 3 3 31/ 2 31/ 2 31/ 2 3 3 15/ 8 3 31/ 2 4 4 41/ 2 41/ 2 41/ 2 4 4 21/ 2 4 41/ 2 23/ 4 23/ 4 31/ 2 31/ 2 31/ 2 23/ 4 23/ 4 13/ 4 23/ 4 31/ 2 160606 160806 161206 161208 161606 4 4 4 5 4 4 4 4 5 4 31/ 2 31/ 2 31/ 2 31/ 2 31/ 2 21/ 2 21/ 2 21/ 2 21/ 2 21/ 2 4 4 4 5 4 11/ 2 21/ 2 4 4 4 3/ 4 11/ 2 21/ 2 21/ 2 31/ 2 — 3/ 4 11/ 2 11/ 2 21/ 2 33/ 8 33/ 8 33/ 8 41/ 4 33/ 8 4 4 4 4 4 11/ 2 2 3 3 4 53/ 8 53/ 8 53/ 8 53/ 8 53/ 8 2 25/ 8 4 4 53/ 8 4 4 4 4 4 — 2 3 3 4 180806 180808 181206 181208 181210 4 5 4 5 6 4 5 4 5 5 4 4 4 4 4 21/ 2 21/ 2 21/ 2 21/ 2 21/ 2 4 5 4 5 6 21/ 2 21/ 2 4 4 4 11/ 4 11/ 4 21/ 2 21/ 2 21/ 2 3/ 4 33/ 8 41/ 4 33/ 8 41/ 4 5 41/ 2 41/ 2 61/ 2 41/ 2 41/ 4 2 2 27/ 8 3 3 6 6 51/ 2 51/ 2 51/ 2 25/ 8 25/ 8 37/ 8 4 4 41/ 2 41/ 2 4 4 4 2 2 23/ 4 23/ 4 23/ 4 060403 060404 060603 060604 060606 11/ 4 2 11/ 4 2 4 3/ 4 11/ 4 11/ 2 11/ 2 080403 080604 080606 080804 080806 11/ 4 2 4 2 4 11/ 4 2 2 2 2 080808 090604 100604 100804 100806 4 2 2 2 4 100808 101006 101008 120604 120606 11/ 2 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 3/ 4 1 1 1 1 — — 3/ 4 3/ 4 3/ 4 11/ 2 11/ 2 11/ 2 7/ 8 Junction Boxes — — — — — 11/ 4 *Spacing dimensions apply to drilled and tapped holes. Space has been provided for a locknut and bushing when drilled and tapped holes are required. †Top and bottom are the longer dimensions on enclosures which are not square. US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 165 W Series Junction Boxes Ordering Information DRILLED AND TAPPED CONDUIT OPENINGS OR SLIP HOLES Table 4 (continued) Maximum Size and Number of Drilled and Tapped Conduit Openings Top and Bottom† Sides Spacing Dimensions* W Series Cat. # 1 2 3 4 3 4 u v w x y 5 5 4 5 6 4 4 4 4 4 21/ 2 21/ 2 21/ 2 21/ 2 21/ 2 4 4 5 5 6 21/ 2 21/ 2 4 31/ 2 4 11/ 2 11/ 2 21/ 2 21/ 2 21/ 2 s 5 5 33/ 8 41/ 4 5 t 6 6 4 5 6 1 6 6 5 5 6 2 181212 181218 181806 181808 181812 41/ 2 41/ 2 41/ 2 41/ 2 41/ 2 3 3 4 4 41/ 2 51/ 2 51/ 2 6 6 6 4 4 53/ 8 53/ 8 6 4 4 41/ 2 41/ 2 41/ 2 21/ 4 23/ 4 4 4 41/ 2 240606 240808 241010 241208 241210 4 5 6 5 6 4 5 6 5 6 4 5 5 5 5 4 4 4 4 4 4 5 6 5 6 11/ 2 21/ 2 3 4 4 3/ 4 11/ 2 21/ 2 21/ 2 — 3/ 4 1 11/ 2 11/ 2 33/ 8 41/ 4 5 41/ 4 5 63/ 4 63/ 4 61/ 2 61/ 2 61/ 2 13/ 8 41/ 2 21/ 2 27/ 8 3 8 8 7 7 7 13/ 4 25/ 8 23/ 4 37/ 8 4 6 6 53/ 4 53/ 4 53/ 4 — 2 21/ 2 23/ 4 23/ 4 241212 241808 241810 241812 242408 6 5 6 6 5 6 5 6 6 5 5 5 5 5 5 4 4 4 4 4 6 5 6 6 5 4 5 6 5 5 21/ 2 4 4 4 5 11/ 2 21/ 2 21/ 2 21/ 2 4 5 41/ 4 5 5 41/ 4 61/ 2 61/ 2 61/ 2 61/ 2 61/ 2 27/ 8 41/ 2 41/ 2 41/ 2 61/ 2 7 7 7 7 7 37/ 8 53/ 4 53/ 4 53/ 4 71/ 2 53/ 4 53/ 4 53/ 4 53/ 4 53/ 4 23/ 4 4 4 4 53/ 4 242412 242424 302412 361212 361812 6 6 6 6 6 6 6 6 6 6 5 5 6 6 6 4 4 5 6 6 6 6 6 6 6 6 6 6 4 5 5 5 5 21/ 2 4 4 4 4 11/ 2 21/ 2 5 61/ 2 5 5 5 61/ 2 63/ 4 71/ 2 83/ 4 83/ 4 61/ 2 61/ 2 63/ 4 3 41/ 2 7 7 10 12 12 71/ 2 71/ 2 8 4 41/ 2 53/ 4 53/ 4 71/ 2 9 9 53/ 4 53/ 4 6 23/ 4 4 362412 363612 6 6 6 6 6 6 6 6 6 6 6 6 5 6 4 6 5 5 83/ 4 83/ 4 63/ 4 83/ 4 12 12 8 12 9 9 6 9 11/ 4 Junction Boxes *Spacing dimensions apply to drilled and tapped holes. Space has been provided for a locknut and bushing when drilled and tapped holes are required. †Top and bottom are the longer dimensions on enclosures which are not square. 166 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Watertight Corrosion-Resistant XD Expansion/Deflection Coupling Applications: Standard Finishes: XD couplings can be installed indoors, outdoors, buried underground, or embedded in concrete in non-hazardous areas. XD’ s are used with standard rigid conduit or PVC rigid conduit. (PVC requires rigid metal conduit nipples and rigid metalto-PVC conduit adapters.) XD’ s provide a flexible and watertight connection for protection of conduit wiring systems from damage due to movement. Typical applications include: • Underground conduit feeder runs • Runs between sections of concrete subject to relative movement • Runs between fixed structures • Conduit entrances in high-rise buildings • Bridges • Marinas, docks, piers • Feraloy – electrogalvanized • Neoprene – natural (black) • Molded plastic – natural (brown) Features: • UL standards: 514B Size Ranges: • 1" to 6" (Smaller sizes can be obtained by using reducing bushings) 1. Axial expansion/contraction. XD Inches Hub Size Cat. # 1 11/ 4 11/ 2 2 21/ 2 XD3 XD4 XD5 XD6 XD7 Hub Size Cat. # 3 31/ 2 4 5 6 XD8 XD9 XD010 XD012 XD014 2. Angular misalignment. Dimensions In Inches: Hub Size 1 11/ 4 11/ 2 2 21/ 2 3 31/ 2 4 5 6 a b 7 73/ 8 71/ 4 71/ 4 71/ 2 75/ 8 73/ 4 77/ 8 73/ 4 83/ 8 315/ 16 41/ 4 41/ 2 415/ 16 55/ 16 515/ 16 61/ 2 615/ 16 8 9 3. Parallel misalignment. Junction Box Accessories • XD couplings accommodate the following movements without collapsing or fracturing the conduit, and damaging the wires it contains: 1. Axial expansion or contraction up to 3/ 4" 2. Angular misalignment of the axes of the coupled conduit runs in any direction to 30° 3. Parallel misalignment of the axes of coupled conduit runs in any direction to 3/ 4" • Inner sleeve maintains constant I.D. in any position and provides a smooth insulated wireway for protection of wire insulation • Watertight flexible neoprene outer jacket is corrosion resistant and protects the grounding strap and the attachment points of the hubs • Tinned copper flexible braid grounding straps assure grounding continuity • Stainless steel jacket clamps for strength and corrosion resistance • Standard tapered electrical threads fit standard rigid conduit • Integral hub bushing protects insulation of conductors Certifications and Compliances: Standard Materials: • • • • • Hubs – Feraloy® iron alloy Outer jacket – molded neoprene Jacket clamps – stainless steel Inner sleeve – molded plastic Grounding straps – tinned copper flexible braid US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 167 XJG Conduit Expansion Joints With Internal Grounding For Rigid Metal Conduit and IMC Wet Locations Applications: XJG expansion couplings are used with rigid metal conduit and IMC: • Without the need for an external bonding jumper and clamps (up to 4") • To couple together two (2) sections of conduit subject to longitudinal movement • In long conduit runs to permit linear movement caused by thermal expansion and contraction • On long conduit runs to prevent conduit from buckling and ensuing circuit failures • Indoors or outdoors where conduit expansion occurs and there are wide temperature ranges • In conduit runs that cross structural joints • In conduit runs to prevent damage to conduit supports such as in a building or on a bridge • With optional redundant visible grounding strap Junction Box Accessories Standard Materials and Finishes: Body • Steel – electrogalvanized • Copper-free aluminum – natural • Feraloy® iron alloy – electrogalvanized (5" + 6" only) Reducer • 1/ 2" through 1" – Steel – electrogalvanized • 11/ 4" through 6" – Feraloy® iron alloy – electrogalvanized and aluminum paint • Copper-free aluminum – natural Gland Nut • 1/ 2" through 1" – Steel – electrogalvanized • 11/ 4" through 6" – Feraloy® iron alloy – electrogalvanized and aluminum paint • Copper–free aluminum – natural Packing • Teflon® (trademark of E.I. DuPont Co.) Washer • Steel – electrogalvanized • Copper-free aluminum – natural Gasket • Vellum Bushing • 1/ 2" through 1" – Steel – electrogalvanized • 11/ 4" through 6" – Feraloy® iron alloy – electrogalvanized and aluminum paint • Copper-free aluminum – natural Ground Springs • Phosphor bronze – electrogalvanized Ground Strap • Braided tinned copper U-Bolts • Malleable iron – electrogalvanized 168 Patent Pending* XJG – For use with rigid metal conduit and IMC Maximum Conduit Movement Cat. # Optional Bonding Jumper A Diameter B Length Bonding Jumper Length 1/ 2 4 8 XJG14 XJG18 BJ14 BJ18 1.75 1.75 6.75 10.75 20" 30" 3/ 4 4 8 XJG24 XJG28 BJ24 BJ28 2.12 2.12 6.75 10.75 20" 30" 1 4 8 XJG34 XJG38 BJ34 BJ38 2.43 2.43 7.25 11.25 20" 30" 11/ 4 4 8 XJG44 XJG48 BJ44 BJ48 3.19 3.19 7.56 11.56 24" 30" 11/ 2 4 8 XJG54 XJG58 BJ54 BJ58 3.68 3.68 7.87 11.87 24" 30" 2 4 8 XJG64 XJG68 BJ64 BJ68 4.75 4.75 8.25 12.25 24" 30" 21/ 2 4 8 XJG74 XJG78 BJ74 BJ78 4.87 4.87 9.31 13.31 24" 36" 3 4 8 XJG84 XJG88 BJ84 BJ88 5.37 5.37 10.00 14.00 30" 36" 31/ 2 4 8 XJG94 XJG98 BJ94 BJ98 6.62 6.62 9.81 13.81 30" 36" 4 4 8 XJG104 XJG108 BJ104 BJ108 6.62 6.62 9.81 13.81 30" 36" 5 8 XJ128‡ — 7.64 15.50 — 6 8 XJ148‡ — 9.56 16.00 — Conduit Size *Teflon® is a registered trademark of E.I. DuPont Co. ‡XJ128 and XJ148 are not internally grounded. A pair of 36" bonding jumpers are provided with fitting. Options: Description Suffix Available in copper-free aluminum SA Available with redundant ground strap for visible indication of grounding – order separately (BJ Series)† †XJG expansion couplings use a metallic bushing and ground springs to create a high integrity internal ground connection. External ground straps offer a redundant ground path and easy visible indication of ground Size Ranges: • 1/ 2" through 6" conduit size • 4" and 8" maximum conduit movement Certifications and Compliances: • • • • • XJG shown with optional bonding jumper UL Standard: 514B CSA Standard: C22.2 No. 18 NEC Articles 250-77 and 300-7 (b) NEMA FB1 Wet Locations US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds XJG-EMT Conduit Expansion Joints With Internal Grounding For EMT Conduit Applications: XJG expansion couplings are used with EMT Conduit: • Without the need for an external bonding jumper and clamps • To couple together two (2) sections of conduit subject to longitudinal movement • In long conduit runs to permit linear movement caused by thermal expansion and contraction • On long conduit runs to prevent conduit from buckling and ensuing circuit failures • Indoors or outdoors where conduit expansion occurs and there are wide temperature ranges • In conduit runs that cross structural joints • In conduit runs to prevent damage to conduit supports such as in a building or on a bridge • With optional redundant visible grounding strap XJG – For use with rigid metal conduit and IMC Conduit Size 1/ 2" Maximum Conduit Movement 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" 3/ 4" 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Cat. # Optional Bonding Jumper XJG14 EMT XJG24 EMT XJG34 EMT XJG44 EMT XJG54 EMT XJG64 EMT XJG74 EMT XJG84 EMT XJG94 EMT XJG104 EMT BJ14 BJ24 BJ34 BJ44 BJ54 BJ64 BJ74 BJ84 BJ94 BJ104 A Diameter B Length 13/ 4" 21/ 8" 27/ 16" 31/ 8" 35/ 8" 43/ 4" 47/ 8" 53/ 8" 65/ 8" 65/ 8" 103/ 4" 11" 111/ 2" 151/ 4" 151/ 2" 151/ 2" 183/ 4" 197/ 8" 211/ 4" 211/ 4" Standard Materials and Finishes: XJG shown with optional bonding jumper *Teflon® is a registered trademark of E.I. DuPont Co. Options: Size Ranges: Description Available with redundant ground strap for visible indication of grounding – order separately (BJ Series)† • 1/ 2" through 4" conduit size • 4" maximum conduit movement †XJG expansion couplings use a metallic bushing and ground springs to create a high integrity internal ground connection. External ground straps offer a redundant ground path and easy visible indication of ground US: 1-866-764-5454 CAN: 1-800-265-0502 Certifications and Compliances: • • • • Junction Box Accessories Body • Steel – electrogalvanized • Copper-free aluminum – natural Reducer • 1/ 2" through 1" – Steel – electrogalvanized • 11/ 4" through 4" – Feraloy® iron alloy – electrogalvanized and aluminum paint Gland Nut • 1/ 2" through 1" – Steel – electrogalvanized • 11/ 4" through 4" – Feraloy® iron alloy – electrogalvanized and aluminum paint Packing • Teflon® (trademark of E.I. DuPont Co.) Washer • Steel – electrogalvanized Gasket • Vellum Bushing • 1/ 2" through 1" – Steel – electrogalvanized • 11/ 4" through 4" – Feraloy® iron alloy – electrogalvanized and aluminum paint Ground Springs • Phosphor bronze – electrogalvanized Ground Strap • Braided tinned copper U-Bolts • Malleable iron – electrogalvanized UL Standard: 514B CSA Standard: C22.2 No. 18 NEC Articles 250-77 and 300-7 (b) NEMA FB1 Copyright© 2007 Cooper Crouse-Hinds 169 Wet Locations XJGD Combination Expansion/Deflection Coupling and Expansion Joint Internally Grounded Applications: XJGD combination fittings are used with rigid metal conduit and IMC: • To accommodate axial expansion, angular misalignment and parallel misalignment • To couple together two (2) sections of conduit subject to longitudinal movement • To maintain a ground connection without the need for an external bonding jumper and clamps • In long conduit runs to prevent conduit from buckling and causing circuit failures • Indoors or outdoors where conduit expansion occurs and there are wide temperature swings • In conduit runs that cross structural joints • In conduit runs to prevent damage to conduit supports such as in a building or on a bridge Hub Size 1" 11/ 4" 11/ 2" 2" 21/ 2" 3" 31/ 2" 4" Maximum Conduit Movement 4" 4" 4" 4" 4" 4" 4" 4" Cat. # XJGD34 XJGD44 XJGD54 XJGD64 XJGD74 XJGD84 XJGD94 XJGD104 Standard Materials: • Body, Hubs, Gland Nut, Washer, Bushing – Feraloy® • Packing – Teflon® • Gasket – vellum • Ground Spring – phosphor bronze • Outer Jacket – molded neoprene • Jacket Clamps – stainless steel • Inner Sleeve – molded plastic • Ground Straps – tinned copper braid Standard Finishes: • Feraloy® – electrogalvanized Certifications and Compliances: Junction Box Accessories • UL Standard: 514B 170 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds A Diameter B Length 315/ 16" 41/ 4" 41/ 2" 415/ 16" 55/ 16" 515/ 16" 61/ 2" 8" 173/ 4" 181/ 8" 185/ 8" 191/ 4" 203/ 4" 215/ 8" 215/ 8" 273/ 4" Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page 0B . . . . . . . . . . . . . . . . . . . . . . .111 10 . . . . . . . . . . . . . . . . . . . . . . .100 1031 . . . . . . . . . . . . . . . . . . . . .100 1031NI . . . . . . . . . . . . . . . . . . .100 1032 . . . . . . . . . . . . . . . . . . . . .100 1032NI . . . . . . . . . . . . . . . . . . .100 1453 . . . . . . . . . . . . . . . . . . . . . .91 1453DC . . . . . . . . . . . . . . . . . . .92 1454 . . . . . . . . . . . . . . . . . . . . . .91 1454DC . . . . . . . . . . . . . . . . . . .92 1455 . . . . . . . . . . . . . . . . . . . . . .91 1455DC . . . . . . . . . . . . . . . . . . .92 1655 . . . . . . . . . . . . . . . . . . . . . .89 1655DC . . . . . . . . . . . . . . . . . . .92 1655RT . . . . . . . . . . . . . . . . . . . .89 1656 . . . . . . . . . . . . . . . . . . . . . .89 1656DC . . . . . . . . . . . . . . . . . . .92 1656RT . . . . . . . . . . . . . . . . . . . .89 1744DC . . . . . . . . . . . . . . . . . . .147 1745 . . . . . . . . . . . . . . . . . . . . .147 1745DC . . . . . . . . . . . . . . . . . . .147 1746 . . . . . . . . . . . . . . . . . . . . .147 1746DC . . . . . . . . . . . . . . . . . . .147 1747 . . . . . . . . . . . . . . . . . . . . .147 1033 . . . . . . . . . . . . . . . . . . . . .100 1033NI . . . . . . . . . . . . . . . . . . .100 1034 . . . . . . . . . . . . . . . . . . . . .100 1034NI . . . . . . . . . . . . . . . . . . .100 1035 . . . . . . . . . . . . . . . . . . . . .100 1035NI . . . . . . . . . . . . . . . . . . .100 1456 . . . . . . . . . . . . . . . . . . .91, 97 1456DC . . . . . . . . . . . . . . . . . . .92 1457 . . . . . . . . . . . . . . . . . . .91, 97 1457DC . . . . . . . . . . . . . . . . . . .92 1458 . . . . . . . . . . . . . . . . . . .91, 97 1458DC . . . . . . . . . . . . . . . . . . .92 1657 . . . . . . . . . . . . . . . . . . . . . .89 1657DC . . . . . . . . . . . . . . . . . . .92 1657RT . . . . . . . . . . . . . . . . . . . .89 1658 . . . . . . . . . . . . . . . . . . . . . .89 1658DC . . . . . . . . . . . . . . . . . . .92 1658RT . . . . . . . . . . . . . . . . . . . .89 1747DC . . . . . . . . . . . . . . . . . . .147 17DC . . . . . . . . . . . . . . . . . . . .100 17X . . . . . . . . . . . . . . . . . . . . . .100 18 . . . . . . . . . . . . . . . . . . . . . . .100 18 SA . . . . . . . . . . . . . . . . . . . .100 188 . . . . . . . . . . . . . . . . . . . . . .106 1036 . . . . . . . . . . . . . . . . . . . . .100 1036NI . . . . . . . . . . . . . . . . . . .100 1037 . . . . . . . . . . . . . . . . . . . . .100 1037NI . . . . . . . . . . . . . . . . . . .100 1038 . . . . . . . . . . . . . . . . . . . . .100 1038NI . . . . . . . . . . . . . . . . . . .100 1459 . . . . . . . . . . . . . . . . . . .91, 97 1459DC . . . . . . . . . . . . . . . . . . .92 14DC . . . . . . . . . . . . . . . . . . . .100 14X . . . . . . . . . . . . . . . . . . . . . .100 15 . . . . . . . . . . . . . . . . . . . . . . .100 15 SA . . . . . . . . . . . . . . . . . . . .100 1659 . . . . . . . . . . . . . . . . . . . . . .89 1659DC . . . . . . . . . . . . . . . . . . .92 1659RT . . . . . . . . . . . . . . . . . . . .89 16DC . . . . . . . . . . . . . . . . . . . .100 16X . . . . . . . . . . . . . . . . . . . . . .100 17 . . . . . . . . . . . . . . . . . . . . . . .100 189 . . . . . . . . . . . . . . . . . . . . . .106 18DC . . . . . . . . . . . . . . . . . . . .100 18X . . . . . . . . . . . . . . . . . . . . . .100 19 . . . . . . . . . . . . . . . . . . . . . . .100 19 SA . . . . . . . . . . . . . . . . . . . .100 190M . . . . . . . . . . . . . . . . . . . . .106 1039 . . . . . . . . . . . . . . . . . . . . .100 1039NI . . . . . . . . . . . . . . . . . . .100 1040 . . . . . . . . . . . . . . . . . . . . .100 1040NI . . . . . . . . . . . . . . . . . . .100 1041 . . . . . . . . . . . . . . . . . . . . .100 1042 . . . . . . . . . . . . . . . . . . . . .100 150 . . . . . . . . . . . . . . . . . .116, 117 150P . . . . . . . . . . . . . . . . . . . . . .97 150S . . . . . . . . . . . . . . . . . . . . . .97 151 . . . . . . . . . . . . . . . . . . . . . . .97 151P . . . . . . . . . . . . . . . . . . . . . .97 152 . . . . . . . . . . . . . . . . . . . . . . .97 17 SA . . . . . . . . . . . . . . . . . . . .100 1707 . . . . . . . . . . . . . . . . . . . . .145 1707DC . . . . . . . . . . . . . . . . . .145 1708 . . . . . . . . . . . . . . . . . . . . .145 1708DC . . . . . . . . . . . . . . . . . .145 1709 . . . . . . . . . . . . . . . . . . . . .145 191 192 193 194 195 196 1050 1051 1052 1053 1054 1055 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 152P . . . . . . . . . . . . . . . . . . . . . .97 153 . . . . . . . . . . . . . . . . . . . . . . .97 153P . . . . . . . . . . . . . . . . . . . . . .97 154 . . . . . . . . . . . . . . . . . . . . . . .97 154P . . . . . . . . . . . . . . . . . . . . . .97 155 . . . . . . . . . . . . . . . . . . . . . . .97 1709DC . . . . . . . . . . . . . . . . . .145 170C . . . . . . . . . . . . . . . . . . . . . .97 1710 . . . . . . . . . . . . . . . . . . . . .145 1710DC . . . . . . . . . . . . . . . . . . .145 1711 . . . . . . . . . . . . . . . . . . . . .145 1711DC . . . . . . . . . . . . . . . . . . .145 197 . . . . . . . . . . . . . . . . . . . . . .106 198 . . . . . . . . . . . . . . . . . . . . . .106 199 . . . . . . . . . . . . . . . . . . . . . .106 19DC . . . . . . . . . . . . . . . . . . . .100 19X . . . . . . . . . . . . . . . . . . . . . .100 1B . . . . . . . . . . . . . . . . . . . . . . .111 1056 1057 1058 1059 1060 1061 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . .106 155P . . . . . . . . . . . . . . . . . . . . . .97 15DC . . . . . . . . . . . . . . . . . . . .100 15X . . . . . . . . . . . . . . . . . . . . . .100 16 . . . . . . . . . . . . . . . . . . . . . . .100 16 SA . . . . . . . . . . . . . . . . . . . .100 160 . . . . . . . . . . . . . . . . . . . . . . .97 1712 . . . . . . . . . . . . . . . . . . . . .145 1712DC . . . . . . . . . . . . . . . . . .145 1713 . . . . . . . . . . . . . . . . . . . . .145 1713DC . . . . . . . . . . . . . . . . . .145 1714 . . . . . . . . . . . . . . . . . . . . .145 1714DC . . . . . . . . . . . . . . . . . .145 2 1/2 B . . . . . . . . . . . . . . . . . . .111 20 . . . . . . . . . . . . . . . . . . . . . . .100 20 SA . . . . . . . . . . . . . . . . . . . .100 200 . . . . . . . . . . . . . . . . . . . . . . .95 201 . . . . . . . . . . . . . . . . . . . . . . .95 202 . . . . . . . . . . . . . . . . . . . . . . .95 10N . . . . . . . . . . . . . . . . . . . . . .136 11 . . . . . . . . . . . . . . . . . . . . . . .100 11 SA . . . . . . . . . . . . . . . . . . . .100 11DC . . . . . . . . . . . . . . . . . . . . .100 11N . . . . . . . . . . . . . . . . . . . . . .136 11X . . . . . . . . . . . . . . . . . . . . . .100 160I . . . . . . . . . . . . . . . . . . . . . .97 160P . . . . . . . . . . . . . . . . . . . . . .97 161 . . . . . . . . . . . . . . . . . . . . . . .97 161I . . . . . . . . . . . . . . . . . . . . . .97 161P . . . . . . . . . . . . . . . . . . . . . .97 162 . . . . . . . . . . . . . . . . . . . . . . .97 1715 . . . . . . . . . . . . . . . . . . . . .145 1715DC . . . . . . . . . . . . . . . . . .145 171C . . . . . . . . . . . . . . . . . . . . . .97 1721 . . . . . . . . . . . . . . . . . . . . .145 1721DC . . . . . . . . . . . . . . . . . .145 1722 . . . . . . . . . . . . . . . . . . . . .145 203 204 205 206 207 208 12 . . . . . . . . . . . . . . . . . . . . . . .100 12 SA . . . . . . . . . . . . . . . . . . . .100 12DC . . . . . . . . . . . . . . . . . . . .100 12N . . . . . . . . . . . . . . . . . . . . . .136 12X . . . . . . . . . . . . . . . . . . . . . .100 13 . . . . . . . . . . . . . . . . . . . . . . .100 163 . . . . . . . . . . . . . . . . . . . . . . .97 164 . . . . . . . . . . . . . . . . . . . . . . .97 165 . . . . . . . . . . . . . . . . . . . . . . .97 1650 . . . . . . . . . . . . . . . . . . . . . .89 1650DC . . . . . . . . . . . . . . . . . . .92 1650RT . . . . . . . . . . . . . . . . . . . .89 1722DC . . . . . . . . . . . . . . . . . .145 1723 . . . . . . . . . . . . . . . . .141, 147 1724DC . . . . . . . . . . . . . . . . . .147 1735 . . . . . . . . . . . . . . . . .141, 147 1736 . . . . . . . . . . . . . . . . . . . . .147 1736DC . . . . . . . . . . . . . . . . . .147 209 . . . . . . . . . . . . . . . . . . .95, 111 20DC . . . . . . . . . . . . . . . . . . . .100 20X . . . . . . . . . . . . . . . . . . . . . .100 22 . . . . . . . . . . . . . . . . . . . . . . .100 23 . . . . . . . . . . . . . . . . . . . . . . .100 2400 . . . . . . . . . . . . . . . . . . . . . .92 13 SA . . . . . . . . . . . . . . . . . . . .100 13DC . . . . . . . . . . . . . . . . . . . .100 13N . . . . . . . . . . . . . . . . . . . . . .136 13X . . . . . . . . . . . . . . . . . . . . . .100 14 . . . . . . . . . . . . . . . . . . . . . . .100 14 SA . . . . . . . . . . . . . . . . . . . .100 1651 . . . . . . . . . . . . . . . . . . . . . .89 1651DC . . . . . . . . . . . . . . . . . . .92 1651RT . . . . . . . . . . . . . . . . . . . .89 1652 . . . . . . . . . . . . . . . . . . . . . .89 1652DC . . . . . . . . . . . . . . . . . . .92 1652RT . . . . . . . . . . . . . . . . . . . .89 1737 . . . . . . . . . . . . . . . . .141, 147 1738 . . . . . . . . . . . . . . . . . . . . .147 1738DC . . . . . . . . . . . . . . . . . .147 1739 . . . . . . . . . . . . . . . . . . . . .147 1739DC . . . . . . . . . . . . . . . . . .147 1740 . . . . . . . . . . . . . . . . . . . . .147 2401 . . . . . . . . . . . . . . . . . . . . . .92 2402 . . . . . . . . . . . . . . . . . . . . . .92 2420 . . . . . . . . . . . . . . . . . .92, 100 2421 . . . . . . . . . . . . . . . . . .92, 100 250 . . . . . . . . . . . . . . . . . .116, 117 251 . . . . . . . . . . . . . . . . . . . . . .113 1450 . . . . . . . . . . . . . . . . . . . . . .91 1450DC . . . . . . . . . . . . . . . . . . .92 1451 . . . . . . . . . . . . . . . . . . . . . .91 1451DC . . . . . . . . . . . . . . . . . . .92 1452 . . . . . . . . . . . . . . . . . . . . . .91 1452DC . . . . . . . . . . . . . . . . . . .92 1653 . . . . . . . . . . . . . . . . . . . . . .89 1653DC . . . . . . . . . . . . . . . . . . .92 1653RT . . . . . . . . . . . . . . . . . . . .89 1654 . . . . . . . . . . . . . . . . . . . . . .89 1654DC . . . . . . . . . . . . . . . . . . .92 1654RT . . . . . . . . . . . . . . . . . . . .89 1740DC . . . . . . . . . . . . . . . . . . .147 1741 . . . . . . . . . . . . . . . . . . . . .147 1741DC . . . . . . . . . . . . . . . . . . .147 1742 . . . . . . . . . . . . . . . . . . . . .147 1742DC . . . . . . . . . . . . . . . . . . .147 1744 . . . . . . . . . . . . . . . . . . . . .147 252 253 254 255 260 261 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . .95, 111 . . . . . . . . . . . . . . . . . . .95, 111 . . . . . . . . . . . . . . . . . . .95, 111 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 171 Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page 262 . . . . . . . . . . . . . . . . . . . . . .113 263 . . . . . . . . . . . . . . . . . . . . . .113 2631 . . . . . . . . . . . . . . . . .149, 151 2632 . . . . . . . . . . . . . . . . .149, 151 2633 . . . . . . . . . . . . . . . . .149, 151 2670 . . . . . . . . . . . . . . . . .149, 151 353 354 355 356 360 361 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 463 . . . . . . . . . . . . . . . . . . . . . . .91 463DC . . . . . . . . . . . . . . . . . . . .92 464 . . . . . . . . . . . . . . . . . . . . . . .91 464DC . . . . . . . . . . . . . . . . . . . .92 465 . . . . . . . . . . . . . . . . . . . . . . .91 465DC . . . . . . . . . . . . . . . . . . . .92 53D . . . . . . . . . . . . . . . . . . . . . .108 54 . . . . . . . . . . . . . . . . . . . . . . .106 54D . . . . . . . . . . . . . . . . . . . . . .108 55 . . . . . . . . . . . . . . . . . . . . . . .106 55D . . . . . . . . . . . . . . . . . . . . . .108 56 . . . . . . . . . . . . . . . . . . . . . . .106 2671 . . . . . . . . . . . . . . . . .149, 151 268 . . . . . . . . . . . . . . . . . . . . . .113 269 . . . . . . . . . . . . . . . . . . . . . .113 2699 . . . . . . . . . . . . .141, 145, 149 270 S . . . . . . . . . . . . . . . . . . . .113 275 . . . . . . . . . . . . . . . . . . . . . .113 362 363 364 365 366 367 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 466 . . . . . . . . . . . . . . . . . . . .91, 97 466DC . . . . . . . . . . . . . . . . . . . .92 467 . . . . . . . . . . . . . . . . . . . .91, 97 467DC . . . . . . . . . . . . . . . . . . . .92 468 . . . . . . . . . . . . . . . . . . . .91, 97 468DC . . . . . . . . . . . . . . . . . . . .92 566 . . . . . . . . . . . . . . . . . . . . . .141 567 . . . . . . . . . . . . . . . . . . . . . .141 56D . . . . . . . . . . . . . . . . . . . . . .108 57 . . . . . . . . . . . . . . . . . . . . . . .106 57D . . . . . . . . . . . . . . . . . . . . . .108 58 . . . . . . . . . . . . . . . . . . . . . . .106 276 281 282 283 285 288 368 369 370 371 372 373 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 S . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 469 . . . . . . . . . . . . . . . . . . . .91, 97 469DC . . . . . . . . . . . . . . . . . . . .92 496 10 . . . . . . . . . . . . . . . .95, 109 496 11 . . . . . . . . . . . . . . . . .95, 109 496 12 . . . . . . . . . . . . . . . .95, 109 496 2 . . . . . . . . . . . . . . . . . . . .109 58D . . . . . . . . . . . . . . . . . . . . . .108 59 . . . . . . . . . . . . . . . . . . . . . . .106 59D . . . . . . . . . . . . . . . . . . . . . .108 6 B . . . . . . . . . . . . . . . . . . . . . . .111 60 . . . . . . . . . . . . . . . . . . . . . . .106 61 . . . . . . . . . . . . . . . . . . . . . . .106 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 . . . . . . . . . . . . . . . . . . . . . .113 289 . . . . . . . . . . . . . . . . . . . . . .113 290M . . . . . . . . . . . . . . . . . . . . .113 291 . . . . . . . . . . . . . . . . . . . . . .113 292 . . . . . . . . . . . . . . . . . . . . . .113 293 . . . . . . . . . . . . . . . . . . . . . .113 294 . . . . . . . . . . . . . . . . . . . . . .113 374 . . . . . . . . . . . . . . . . . . . . . .109 375 . . . . . . . . . . . . . . . . . . . . . .109 376 . . . . . . . . . . . . . . . . . . . . . .109 377 . . . . . . . . . . . . . . . . . . . . . .109 378 . . . . . . . . . . . . . . . . . . . . . .109 4 B . . . . . . . . . . . . . . . . . . . . . . .111 496 496 496 496 496 496 3 4 5 6 7 8 . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . .109 631 . . . . . . . . . . . . . . . . . .149, 151 632 . . . . . . . . . . . . . . . . . .149, 151 65 . . . . . . . . . . . . . . . . . . . . . . .100 650 . . . . . . . . . . . . . . . . . .116, 117 650DC . . . . . . . . . . . . . . . . . . . .92 650RT . . . . . . . . . . . . . . . . . . . . .89 295 . . . . . . . . . . . . . . . . . . . . . .113 296 . . . . . . . . . . . . . . . . . . . . . .113 297 . . . . . . . . . . . . . . . . . . . . . .113 298 . . . . . . . . . . . . . . . . . . . . . .113 299 . . . . . . . . . . . . . . . . . . . . . .113 2B . . . . . . . . . . . . . . . . . . . . . . .111 410 . . . . . . . . . . . . . . . . . . . . . .111 411 . . . . . . . . . . . . . . . . . . . . . . .111 412 . . . . . . . . . . . . . . . . . . . . . .111 413 . . . . . . . . . . . . . . . . . . . . . .111 414 . . . . . . . . . . . . . . . . . . . . . .111 415 . . . . . . . . . . . . . . . . . . . . . .111 496 497 497 497 497 497 9 1 2 3 4 5 . . . . . . . . . . . . . . . . .95, 109 . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . . . .95 . . . . . . . . . . . . . . . . . . . . .95 650S . . . . . . . . . . . . . . . . . . . . . .89 651DC . . . . . . . . . . . . . . . . . . . .92 651RT . . . . . . . . . . . . . . . . . . . . .89 651S . . . . . . . . . . . . . . . . . . . . . .89 652 . . . . . . . . . . . . . . . . . . . . . . .89 652DC . . . . . . . . . . . . . . . . . . . .92 3 B . . . . . . . . . . . . . . . . . . . . . . .111 300 . . . . . . . . . . . . . . . . . . . . . .108 3000 . . . . . . . . . . . . . . . . . . . . .151 300DC . . . . . . . . . . . . . . . . . . .108 301 . . . . . . . . . . . . . . . . . . . . . .108 301DC . . . . . . . . . . . . . . . . . . . .108 420 . . . . . . . . . . . . . . . . . . .92, 100 421 . . . . . . . . . . . . . . . . . . .92, 100 422 . . . . . . . . . . . . . . . . . . .92, 100 450 . . . . . . . . . . . . . . . . . .116, 117 450DC . . . . . . . . . . . . . . . . . . . .92 450S . . . . . . . . . . . . . . . . . . . . . .91 497 6 . . . . . . . . . . . . . . . . . . . . .95 5 B . . . . . . . . . . . . . . . . . . . . . . .111 50 . . . . . . . . . . . . . . . . . . . . . . .106 5050 . . . . . . . . . . . . . . . . . . . . .149 50D . . . . . . . . . . . . . . . . . . . . . .108 51 . . . . . . . . . . . . . . . . . . . . . . .106 652RT . . . . . . . . . . . . . . . . . . . . .89 653 . . . . . . . . . . . . . . . . . . . . . . .89 653DC . . . . . . . . . . . . . . . . . . . .92 653RT . . . . . . . . . . . . . . . . . . . . .89 654 . . . . . . . . . . . . . . . . . . . . . . .89 654DC . . . . . . . . . . . . . . . . . . . .92 302 . . . . . . . . . . . . . . . . . . . . . .108 302DC . . . . . . . . . . . . . . . . . . .108 303 . . . . . . . . . . . . . . . . . . . . . .108 303DC . . . . . . . . . . . . . . . . . . .108 304DC . . . . . . . . . . . . . . . . . . .108 305DC . . . . . . . . . . . . . . . . . . .108 451 . . . . . . . . . . . . . . . . . . . . . . .91 451DC . . . . . . . . . . . . . . . . . . . .92 452 . . . . . . . . . . . . . . . . . . . . . . .91 452DC . . . . . . . . . . . . . . . . . . . .92 453 . . . . . . . . . . . . . . . . . . . . . . .91 453DC . . . . . . . . . . . . . . . . . . . .92 510 511 512 513 514 515 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 654RT . . . . . . . . . . . . . . . . . . . . .89 655 . . . . . . . . . . . . . . . . . . . . . . .89 655DC . . . . . . . . . . . . . . . . . . . .92 655RT . . . . . . . . . . . . . . . . . . . . .89 656 . . . . . . . . . . . . . . . . . . . . . . .89 656DC . . . . . . . . . . . . . . . . . . . .92 335 336 337 338 339 340 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 454 . . . . . . . . . . . . . . . . . . . . . . .91 454DC . . . . . . . . . . . . . . . . . . . .92 455 . . . . . . . . . . . . . . . . . . . . . . .91 455DC . . . . . . . . . . . . . . . . . . . .92 456 . . . . . . . . . . . . . . . . . . . .91, 97 456DC . . . . . . . . . . . . . . . . . . . .92 516 . . . . . . . . . . . . . . . . . . .95, 109 517 . . . . . . . . . . . . . . . . . . .95, 109 518 . . . . . . . . . . . . . . . . . . .95, 109 519 . . . . . . . . . . . . . . . . . . .95, 109 51D . . . . . . . . . . . . . . . . . . . . . .108 52 . . . . . . . . . . . . . . . . . . . . . . .106 656RT . . . . . . . . . . . . . . . . . . . . .89 657 . . . . . . . . . . . . . . . . . . . . . . .89 657DC . . . . . . . . . . . . . . . . . . . .92 657RT . . . . . . . . . . . . . . . . . . . . .89 658 . . . . . . . . . . . . . . . . . . . . . . .89 658DC . . . . . . . . . . . . . . . . . . . .92 342 343 344 345 346 347 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 . . . . . . . . . . . . . . . . . . . . . .109 457 . . . . . . . . . . . . . . . . . . . .91, 97 457DC . . . . . . . . . . . . . . . . . . . .92 458 . . . . . . . . . . . . . . . . . . . .91, 97 458DC . . . . . . . . . . . . . . . . . . . .92 459 . . . . . . . . . . . . . . . . . . . .91, 97 459DC . . . . . . . . . . . . . . . . . . . .92 520 . . . . . . . . . . . . . . . . . . . . . .109 521 . . . . . . . . . . . . . . . . . . . . . .109 528 . . . . . . . . . . . . . . . . . . . . . .111 529 . . . . . . . . . . . . . . . . . . . . . .111 529 S . . . . . . . . . . . . . . . . . . . . .111 52D . . . . . . . . . . . . . . . . . . . . . .108 658RT . . . . . . . . . . . . . . . . . . . . .89 659 . . . . . . . . . . . . . . . . . . . . . . .89 659DC . . . . . . . . . . . . . . . . . . . .92 659RT . . . . . . . . . . . . . . . . . . . . .89 66 . . . . . . . . . . . . . . . . . . . . . . .100 660DC . . . . . . . . . . . . . . . . . . . .92 348 . . . . . . . . . . . . . . . . . . . . . .109 349 . . . . . . . . . . . . . . . . . . . . . .109 350 . . . . . . . . . . . . . . . . . .116, 117 350S . . . . . . . . . . . . . . . . . . . . .109 351 . . . . . . . . . . . . . . . . . . . . . .109 352 . . . . . . . . . . . . . . . . . . . . . .109 460 . . . . . . . . . . . . . . . . . . . . . . .91 460DC . . . . . . . . . . . . . . . . . . . .92 461 . . . . . . . . . . . . . . . . . . . . . . .91 461DC . . . . . . . . . . . . . . . . . . . .92 462 . . . . . . . . . . . . . . . . . . . . . . .91 462DC . . . . . . . . . . . . . . . . . . . .92 53 . . . . . . . . . . . . . . . . . . . . . . .106 530 . . . . . . . . . . . . . . . . . . . . . .111 531 . . . . . . . . . . . . . . . . . . . . . .111 532 . . . . . . . . . . . . . . . . . . . . . .111 533 . . . . . . . . . . . . . . . . . . . . . .111 534 . . . . . . . . . . . . . . . . . . . . . .111 660RT . . . . . . . . . . . . . . . . . . . . .89 660S . . . . . . . . . . . . . . . . . . . . . .89 661DC . . . . . . . . . . . . . . . . . . . .92 661RT . . . . . . . . . . . . . . . . . . . . .89 661S . . . . . . . . . . . . . . . . . . . . . .89 662 . . . . . . . . . . . . . . . . . . . . . . .89 172 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page 662DC . . . . . . . . . . . . . . . . . . . .92 662RT . . . . . . . . . . . . . . . . . . . . .89 663 . . . . . . . . . . . . . . . . . . . . . . .89 663DC . . . . . . . . . . . . . . . . . . . .92 663RT . . . . . . . . . . . . . . . . . . . . .89 664 . . . . . . . . . . . . . . . . . . . . . . .89 737 . . . . . . . . . . . . . . . . . .141, 147 738 . . . . . . . . . . . . . . . . . . . . . .147 738DC . . . . . . . . . . . . . . . . . . .147 739 . . . . . . . . . . . . . . . . . . . . . .147 739DC . . . . . . . . . . . . . . . . . . .147 740 . . . . . . . . . . . . . . . . . . . . . .147 875EB DC . . . . . . . . . . . . . . . . .95 875EE DC . . . . . . . . . . . . . . . . .95 875RB DC . . . . . . . . . . . . . . . .108 875RR DC . . . . . . . . . . . . . . . .108 9 B . . . . . . . . . . . . . . . . . . . . . . .111 90 . . . . . . . . . . . . . . . . . . . . . . .109 ASB 8 . . . . . . . . . . . . . . . .141, 149 BJ104 . . . . . . . . . . . . . . . .168, 169 BJ108 . . . . . . . . . . . . . . . . . . . .168 BJ14 . . . . . . . . . . . . . . . . .168, 169 BJ18 . . . . . . . . . . . . . . . . . . . . .168 BJ24 . . . . . . . . . . . . . . . . .168, 169 664DC . . . . . . . . . . . . . . . . . . . .92 664RT . . . . . . . . . . . . . . . . . . . . .89 665 . . . . . . . . . . . . . . . . . . . . . . .89 665DC . . . . . . . . . . . . . . . . . . . .92 665RT . . . . . . . . . . . . . . . . . . . . .89 666 . . . . . . . . . . . . . . . . . . . . . . .89 740DC . . . . . . . . . . . . . . . . . . . .147 741 . . . . . . . . . . . . . . . . . . . . . .147 741DC . . . . . . . . . . . . . . . . . . . .147 742 . . . . . . . . . . . . . . . . . . . . . .147 742DC . . . . . . . . . . . . . . . . . . . .147 744 . . . . . . . . . . . . . . . . . . . . . .147 91 . . . . . . . . . . . . . . . . . . . . . . .109 92 . . . . . . . . . . . . . . . . . . . . . . .109 93 . . . . . . . . . . . . . . . . . . . . . . .109 931 . . . . . . . . . . . . . . . . . . . . . .104 932 . . . . . . . . . . . . . . . . . . . . . .104 933 . . . . . . . . . . . . . . . . . . . . . .104 BJ28 BJ34 BJ38 BJ44 BJ48 BJ54 . . . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . .168, 169 . . . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . .168, 169 . . . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . .168, 169 666DC . . . . . . . . . . . . . . . . . . . .92 666RT . . . . . . . . . . . . . . . . . . . . .89 667 . . . . . . . . . . . . . . . . . . . . . . .89 667DC . . . . . . . . . . . . . . . . . . . .92 667RT . . . . . . . . . . . . . . . . . . . . .89 668 . . . . . . . . . . . . . . . . . . . . . . .89 744DC . . . . . . . . . . . . . . . . . . . .147 745 . . . . . . . . . . . . . . . . . . . . . .147 745DC . . . . . . . . . . . . . . . . . . . .147 746 . . . . . . . . . . . . . . . . . . . . . .147 746DC . . . . . . . . . . . . . . . . . . . .147 747 . . . . . . . . . . . . . . . . . . . . . .147 934 935 936 937 938 939 BJ58 BJ64 BJ68 BJ74 BJ78 BJ84 . . . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . .168, 169 . . . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . .168, 169 . . . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . .168, 169 668DC . . . . . . . . . . . . . . . . . . . .92 668RT . . . . . . . . . . . . . . . . . . . . .89 669 . . . . . . . . . . . . . . . . . . . . . . .89 669DC . . . . . . . . . . . . . . . . . . . .92 669RT . . . . . . . . . . . . . . . . . . . . .89 67 . . . . . . . . . . . . . . . . . . . . . . .100 747DC . . . . . . . . . . . . . . . . . . . .147 759DC . . . . . . . . . . . . . . . . . . .149 770DC . . . . . . . . . . . . . . . . . . .147 771DC . . . . . . . . . . . . . . . . . . .147 772DC . . . . . . . . . . . . . . . . . . .147 773DC . . . . . . . . . . . . . . . . . . .147 94 . . . . . . . . . . . . . . . . . . . . . . .109 940 . . . . . . . . . . . . . . . . . . . . . .104 941 . . . . . . . . . . . . . . . . . . . . . .104 942 . . . . . . . . . . . . . . . . . . . . . .104 95 . . . . . . . . . . . . . . . . . . . . . . .109 950D . . . . . . . . . . . . . . . . .116, 117 BJ88 . . . . . . . . . . . . . . . . . . . . .168 BJ94 . . . . . . . . . . . . . . . . .168, 169 BJ98 . . . . . . . . . . . . . . . . . . . . .168 BSC50DC . . . . . . . . . . . . . . . . . .95 BSC75DC . . . . . . . . . . . . . . . . . .95 BSS50 . . . . . . . . . . . . . . . . . . . .95 68 . . . . . . . . . . . . . . . . . . . . . . .100 690S . . . . . . . . . . . . . . . . . . .91, 99 691 . . . . . . . . . . . . . . . . . . . .91, 99 692 . . . . . . . . . . . . . . . . . . . .91, 99 699 . . . . . . . . . . . . . . . . . .141, 145 7 B . . . . . . . . . . . . . . . . . . . . . . .111 774DC . . . . . . . . . . . . . . . . . . . .147 775DC . . . . . . . . . . . . . . . . . . .147 776DC . . . . . . . . . . . . . . . . . . .147 780DC . . . . . . . . . . . . . . . .95, 149 791DC . . . . . . . . . . . . . . . . . . .147 792DC . . . . . . . . . . . . . . . . . . .147 96 . . . . . . . . . . . . . . . . . . . . . . .109 97 . . . . . . . . . . . . . . . . . . . . . . .109 98 . . . . . . . . . . . . . . . . . . . . . . .109 99 . . . . . . . . . . . . . . . . . . . . . . .109 ACB100 . . . . . . . . . . . . . .139, 143 ACB10090 . . . . . . . . . . . .139, 143 BSS75 . . . . . . . . . . . . . . . . . . . .95 C100M . . . . . . . . . . . . . . . . . . .121 C105 . . . . . . . . . . . . . . . . . . . . .117 C125M . . . . . . . . . . . . . . . . . . .121 C15 . . . . . . . . . . . . . . . . . . . . . .117 C15 MT . . . . . . . . . . . . . . . . . . .116 700 . . . . . . . . . . . . . . . . . .141, 145 702V . . . . . . . . . . . . . . . . .141, 145 707 . . . . . . . . . . . . . . . . . . . . . .145 707DC . . . . . . . . . . . . . . . . . . .145 708 . . . . . . . . . . . . . . . . . . . . . .145 708DC . . . . . . . . . . . . . . . . . . .145 793DC . . . . . . . . . . . . . . . . . . .147 794DC . . . . . . . . . . . . . . . . . . .147 795DC . . . . . . . . . . . . . . . . . . .147 796DC . . . . . . . . . . . . . . . . . . .147 8 B . . . . . . . . . . . . . . . . . . . . . . .111 810 . . . . . . . . . . . . . . . . . . . . . .108 ACB125 ACB150 ACB200 ACB250 ACB300 ACB350 . . . . . . . . . . . . . .139, . . . . . . . . . . . . . .139, . . . . . . . . . . . . . .139, . . . . . . . . . . . . . .139, . . . . . . . . . . . . . .139, . . . . . . . . . . . . . .139, 143 143 143 143 143 143 C150M . . . . . . . . . . . . . . . . . . .121 C200M . . . . . . . . . . . . . . . . . . .121 C25 . . . . . . . . . . . . . . . . . . . . . .117 C25 MT . . . . . . . . . . . . . . . . . . .116 C250M . . . . . . . . . . . . . . . . . . .121 C300M . . . . . . . . . . . . . . . . . . .121 709 . . . . . . . . . . . . . . . . . . . . . .145 709DC . . . . . . . . . . . . . . . . . . .145 710 . . . . . . . . . . . . . . . . . . . . . .145 710DC . . . . . . . . . . . . . . . . . . .145 711 . . . . . . . . . . . . . . . . . . . . . .145 711DC . . . . . . . . . . . . . . . . . . . .145 8100EB DC . . . . . . . . . . . . . . . .95 8100EE DC . . . . . . . . . . . . . . . .95 8100RB DC . . . . . . . . . . . . . . .108 8100RR DC . . . . . . . . . . . . . . .108 811 . . . . . . . . . . . . . . . . . . . . . .108 812 . . . . . . . . . . . . . . . . . . . . . .108 ACB38 . . . . . . . . . . . . . . .139, ACB3845 . . . . . . . . . . . . .139, ACB3890 . . . . . . . . . . . . .139, ACB400 . . . . . . . . . . . . . .139, ACB50 . . . . . . . . . . . . . . .139, ACB5045 . . . . . . . . . . . . .139, 143 143 143 143 143 143 C35 . . . . . . . . . . . . . . . . . . . . . .117 C35 MT . . . . . . . . . . . . . . . . . . .116 C350M . . . . . . . . . . . . . . . . . . .121 C400M . . . . . . . . . . . . . . . . . . .121 C45 . . . . . . . . . . . . . . . . . . . . . .117 C45 MT . . . . . . . . . . . . . . . . . . .116 712 . . . . . . . . . . . . . . . . . . . . . .145 712DC . . . . . . . . . . . . . . . . . . .145 713 . . . . . . . . . . . . . . . . . . . . . .145 713DC . . . . . . . . . . . . . . . . . . .145 714 . . . . . . . . . . . . . . . . . . . . . .145 714DC . . . . . . . . . . . . . . . . . . .145 8125EB DC . . . . . . . . . . . . . . . .95 8125EE DC . . . . . . . . . . . . . . . .95 8125RB DC . . . . . . . . . . . . . . .108 8125RR DC . . . . . . . . . . . . . . .108 813 . . . . . . . . . . . . . . . . . . . . . .108 814 . . . . . . . . . . . . . . . . . . . . . .108 ACB5090 . . . . . . . . . . . . .139, ACB75 . . . . . . . . . . . . . . .139, ACB7545 . . . . . . . . . . . . .139, ACB7590 . . . . . . . . . . . . .139, ACC38 . . . . . . . . . . . . . . .140, ACC50 . . . . . . . . . . . . . . .140, 143 143 143 143 143 143 C50M . . . . . . . . . . . . . . . . . . . .121 C55 . . . . . . . . . . . . . . . . . . . . . .117 C55 MT . . . . . . . . . . . . . . . . . . .116 C65 . . . . . . . . . . . . . . . . . . . . . .117 C65 MT . . . . . . . . . . . . . . . . . . .116 C75 . . . . . . . . . . . . . . . . . . . . . .117 715 . . . . . . . . . . . . . . . . . . . . . .145 715DC . . . . . . . . . . . . . . . . . . .145 721 . . . . . . . . . . . . . . . . . . . . . .145 721DC . . . . . . . . . . . . . . . . . . .145 722 . . . . . . . . . . . . . . . . . . . . . .145 722DC . . . . . . . . . . . . . . . . . . .145 815 820 821 822 823 824 ACC75 . . . . . . . . . . . . . . .140, ACCSS38 . . . . . . . . . . . . .140, ACCSS50 . . . . . . . . . . . . .140, ACCSS75 . . . . . . . . . . . . .140, ASB 0 . . . . . . . . . . . . . . . .141, ASB 1 . . . . . . . . . . . . . . . .141, 143 143 143 143 149 149 C75M . . . . . . . . . . . . . . . . . . . .121 C85 . . . . . . . . . . . . . . . . . . . . . .117 C95 . . . . . . . . . . . . . . . . . . . . . .117 CB1 . . . . . . . . . . . . . . . . . .95, 109 CB10 . . . . . . . . . . . . . . . . . .95, 109 CB11 . . . . . . . . . . . . . . . . . .95, 109 723 . . . . . . . . . . . . . . . . . .141, 147 724 . . . . . . . . . . . . . . . . . . . . . .147 724DC . . . . . . . . . . . . . . . . . . .147 735 . . . . . . . . . . . . . . . . . .141, 147 736 . . . . . . . . . . . . . . . . . . . . . .147 736DC . . . . . . . . . . . . . . . . . . .147 825 . . . . . . . . . . . . . . . . . . . . . .108 850D . . . . . . . . . . . . . . . . .116, 117 850EB DC . . . . . . . . . . . . . . . . .95 850EE DC . . . . . . . . . . . . . . . . .95 850RB DC . . . . . . . . . . . . . . . .108 850RR DC . . . . . . . . . . . . . . . .108 ASB ASB ASB ASB ASB ASB 149 149 149 149 149 149 CB12 . . . . . . . . . . . . . . . . . .95, CB2 . . . . . . . . . . . . . . . . . .95, CB3 . . . . . . . . . . . . . . . . . .95, CB4 . . . . . . . . . . . . . . . . . .95, CB5 . . . . . . . . . . . . . . . . . .95, CB6 . . . . . . . . . . . . . . . . . .95, . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . . . . . .108 US: 1-866-764-5454 CAN: 1-800-265-0502 . . . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . . . .104 2 3 4 5 6 7 . . . . . . . . . . . . . . . .141, . . . . . . . . . . . . . . . .141, . . . . . . . . . . . . . . . .141, . . . . . . . . . . . . . . . .141, . . . . . . . . . . . . . . . .141, . . . . . . . . . . . . . . . .141, Copyright© 2007 Cooper Crouse-Hinds 109 109 109 109 109 109 173 Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page CB7 . . . . . . . . . . . . . . . . . .95, 109 CB8 . . . . . . . . . . . . . . . . . .95, 109 CB9 . . . . . . . . . . . . . . . . . .95, 109 CG100 1050 . . . . . . . . . . . . . . .136 CG100 560 . . . . . . . . . . . . . . . .136 CG100 650 . . . . . . . . . . . . . . . .136 CG7590 CG7590 CG7590 CG7590 CG7590 CG7590 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 EHSS9 . . . . . . . . . . . . . . . . . . .151 EHT1 . . . . . . . . . . . . . . . . . . . .151 EHT10 . . . . . . . . . . . . . . . . . . .151 EHT2 . . . . . . . . . . . . . . . . . . . .151 EHT3 . . . . . . . . . . . . . . . . . . . .151 EHT4 . . . . . . . . . . . . . . . . . . . .151 GLL10C . . . . . . . . . . . . . . . . . .102 GLL11 . . . . . . . . . . . . . . . . .85, 102 GLL11 250 . . . . . . . . . . . . . . . .102 GLL11 250C . . . . . . . . . . . . . . .102 GLL11C . . . . . . . . . . . . . . . . . .102 GLL12 . . . . . . . . . . . . . . . . .85, 102 CG100 750 . . . . . . . . . . . . . . . .136 CG100 850 . . . . . . . . . . . . . . . .136 CG100 950 . . . . . . . . . . . . . . . .136 CG10045 1050 . . . . . . . . . . . . .136 CG10045 560 . . . . . . . . . . . . . .136 CG10045 650 . . . . . . . . . . . . . .136 CG7590 850 . . . . . . . . . . . . . . .136 CPR1 . . . . . . . . . . . . . . . . . . . . .97 CPR10 . . . . . . . . . . . . . . . . . . . .97 CPR11 . . . . . . . . . . . . . . . . . . . .97 CPR12 . . . . . . . . . . . . . . . . . . . .97 CPR13 . . . . . . . . . . . . . . . . . . . .97 EHT5 . . . . . . . . . . . . . . . . . . . .151 EHT6 . . . . . . . . . . . . . . . . . . . .151 EHT7 . . . . . . . . . . . . . . . . . . . .151 EHT8 . . . . . . . . . . . . . . . . . . . .151 EHT9 . . . . . . . . . . . . . . . . . . . .151 ETC100HD . . . . . . . . . . . . . . . .111 GLL12 250 . . . . . . . . . . . . . . . .102 GLL12 250C . . . . . . . . . . . . . . .102 GLL12C . . . . . . . . . . . . . . . . . .102 GLL1C . . . . . . . . . . . . . . . . . . .102 GLL2 . . . . . . . . . . . . . . . . . .85, 102 GLL2 DC . . . . . . . . . . . . . . . . .102 CG10045 CG10045 CG10045 CG10090 CG10090 CG10090 CPR14 CPR15 CPR16 CPR17 CPR18 CPR19 . . . . . . . . . . . . . . . . . . . .97 . . . . . . . . . . . . . . . . . . . .97 . . . . . . . . . . . . . . . . . . . .97 . . . . . . . . . . . . . . . . . . . .97 . . . . . . . . . . . . . . . . . . . .97 . . . . . . . . . . . . . . . . . . . .97 ETC125HD . . . . . . . . . . . . . . . .111 ETC150HD . . . . . . . . . . . . . . . .111 ETC200HD . . . . . . . . . . . . . . . .111 ETC250HD . . . . . . . . . . . . . . . .111 ETC300HD . . . . . . . . . . . . . . . .111 ETC50HD . . . . . . . . . . . . . . . . .111 GLL2C . . . . . . . . . . . . . . . . . . .102 GLL3 . . . . . . . . . . . . . . . . . .85, 102 GLL3 DC . . . . . . . . . . . . . . . . .102 GLL3C . . . . . . . . . . . . . . . . . . .102 GLL4 . . . . . . . . . . . . . . . . . .85, 102 GLL4 10 . . . . . . . . . . . . . . . . . .102 CG10090 750 . . . . . . . . . . . . . .136 CG10090 850 . . . . . . . . . . . . . .136 CG10090 950 . . . . . . . . . . . . . .136 CG125 1050 . . . . . . . . . . . . . . .136 CG125 1150 . . . . . . . . . . . . . . .136 CG125 1250 . . . . . . . . . . . . . . .136 CPR2 . . . . . . . . . . . . . . . . . . . . .97 CPR20 . . . . . . . . . . . . . . . . . . . .97 CPR21 . . . . . . . . . . . . . . . . . . . .97 CPR22 . . . . . . . . . . . . . . . . . . . .97 CPR23 . . . . . . . . . . . . . . . . . . . .97 CPR24 . . . . . . . . . . . . . . . . . . . .97 ETC75HD . . . . . . . . . . . . . . . . .111 FEA100 . . . . . . . . . . . . . . . . . . .131 FEA125 . . . . . . . . . . . . . . . . . . .131 FEA150 . . . . . . . . . . . . . . . . . . .131 FEA200 . . . . . . . . . . . . . . . . . .131 FEA250 . . . . . . . . . . . . . . . . . .131 GLL4 10C . . . . . . . . . . . . . . . . .102 GLL4 DC . . . . . . . . . . . . . . . . .102 GLL4C . . . . . . . . . . . . . . . . . . .102 GLL5 . . . . . . . . . . . . . . . . . .85, 102 GLL5 10 . . . . . . . . . . . . . . . . . .102 GLL5 10C . . . . . . . . . . . . . . . . .102 CG125 CG125 CG125 CG150 CG150 CG150 1375 . . . . . . . . . . . . . . .136 850 . . . . . . . . . . . . . . . .136 950 . . . . . . . . . . . . . . . .136 1050 . . . . . . . . . . . . . . .136 1150 . . . . . . . . . . . . . . .136 1250 . . . . . . . . . . . . . . .136 CPR25 . . . . . . . . . . . . . . . . . . . .97 CPR26 . . . . . . . . . . . . . . . . . . . .97 CPR27 . . . . . . . . . . . . . . . . . . . .97 CPR28 . . . . . . . . . . . . . . . . . . . .97 CPR29 . . . . . . . . . . . . . . . . . . . .97 CPR3 . . . . . . . . . . . . . . . . . . . . .97 FEA300 . . . . . . . . . . . . . . . . . .131 FEA350 . . . . . . . . . . . . . . . . . .131 FEA38 . . . . . . . . . . . . . . . . . . .131 FEA400 . . . . . . . . . . . . . . . . . .131 FEA50 . . . . . . . . . . . . . . . . . . .131 FEA75 . . . . . . . . . . . . . . . . . . .131 GLL5 DC . . . . . . . . . . . . . . . . .102 GLL5C . . . . . . . . . . . . . . . . . . .102 GLL6 . . . . . . . . . . . . . . . . . .85, 102 GLL6 10 . . . . . . . . . . . . . . . . . .102 GLL6 10C . . . . . . . . . . . . . . . . .102 GLL6 DC . . . . . . . . . . . . . . . . .102 CG150 1375 . . . . . . . . . . . . . . .136 CG50 250 . . . . . . . . . . . . . . . . .136 CG50 350 . . . . . . . . . . . . . . . . .136 CG50 450 . . . . . . . . . . . . . . . . .136 CG50 560 . . . . . . . . . . . . . . . . .136 CG50 650 . . . . . . . . . . . . . . . . .136 CPR30 . . . . . . . . . . . . . . . . . . . .97 CPR4 . . . . . . . . . . . . . . . . . . . . .97 CPR5 . . . . . . . . . . . . . . . . . . . . .97 CPR6 . . . . . . . . . . . . . . . . . . . . .97 CPR7 . . . . . . . . . . . . . . . . . . . . .97 CPR8 . . . . . . . . . . . . . . . . . . . . .97 GASK015N GASK025N GASK035N GASK045N GASK065N GASK085N 117 117 117 117 117 117 GLL6C . . . . . . . . . . . . . . . .85, 102 GLL7 . . . . . . . . . . . . . . . . . .85, 102 GLL7 250 . . . . . . . . . . . . . . . . .102 GLL7 250C . . . . . . . . . . . . .85, 102 GLL7 30 . . . . . . . . . . . . . . . . . .102 GLL7 30C . . . . . . . . . . . . . . . . .102 CG5045 CG5045 CG5045 CG5045 CG5045 CG5090 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 CPR9 . . . . . . . . . . . . . . . . . . . . .97 EHC1 . . . . . . . . . . . . . . . . . . . .151 EHC10 . . . . . . . . . . . . . . . . . . .151 EHC2 . . . . . . . . . . . . . . . . . . . .151 EHC3 . . . . . . . . . . . . . . . . . . . .151 EHC4 . . . . . . . . . . . . . . . . . . . .151 GASK095N . . . . . . . . . . . .116, 117 GK100N . . . . . . . . . . . . . . . . . .121 GK125N . . . . . . . . . . . . . . . . . .121 GK200N . . . . . . . . . . . . . . . . . .121 GK250N . . . . . . . . . . . . . . . . . .121 GK350N . . . . . . . . . . . . . . . . . .121 GLL7 DC . . . . . . . . . . . . . . . . .102 GLL7C . . . . . . . . . . . . . . . . . . .102 GLL8 . . . . . . . . . . . . . . . . . .85, 102 GLL8 250 . . . . . . . . . . . . . . . . .102 GLL8 250C . . . . . . . . . . . . . . . .102 GLL8 30 . . . . . . . . . . . . . . . . . .102 CG5090 350 . . . . . . . . . . . . . . .136 CG5090 450 . . . . . . . . . . . . . . .136 CG5090 560 . . . . . . . . . . . . . . .136 CG5090 650 . . . . . . . . . . . . . . .136 CG75 250 . . . . . . . . . . . . . . . . .136 CG75 350 . . . . . . . . . . . . . . . . .136 EHC5 . . . . . . . . . . . . . . . . . . . .151 EHC6 . . . . . . . . . . . . . . . . . . . .151 EHC7 . . . . . . . . . . . . . . . . . . . .151 EHC8 . . . . . . . . . . . . . . . . . . . .151 EHC9 . . . . . . . . . . . . . . . . . . . .151 EHMT1 . . . . . . . . . . . . . . . . . . .151 GK50N . . . . . . . . . . . . . . . . . . .121 GK75N . . . . . . . . . . . . . . . . . . .121 GL 11 . . . . . . . . . . . . . . . . . . . .100 GL 12 . . . . . . . . . . . . . . . . . . . .100 GL 13 . . . . . . . . . . . . . . . . . . . .100 GL 14 . . . . . . . . . . . . . . . . . . . .100 GLL8 30C . . . . . . . . . . . . . . . . .102 GLL8 DC . . . . . . . . . . . . . . . . .102 GLL8C . . . . . . . . . . . . . . . . . . .102 GLL9 . . . . . . . . . . . . . . . . . .85, 102 GLL9 250 . . . . . . . . . . . . . . . . .102 GLL9 250C . . . . . . . . . . . . . . . .102 CG75 450 . . . . . . . . . . . . . . . . .136 CG75 560 . . . . . . . . . . . . . . . . .136 CG75 650 . . . . . . . . . . . . . . . . .136 CG75 750 . . . . . . . . . . . . . . . . .136 CG75 850 . . . . . . . . . . . . . . . . .136 CG7545 250 . . . . . . . . . . . . . . .136 EHMT2 . . . . . . . . . . . . . . . . . . .151 EHMT3 . . . . . . . . . . . . . . . . . . .151 EHMT4 . . . . . . . . . . . . . . . . . . .151 EHSS1 . . . . . . . . . . . . . . . . . . .151 EHSS10 . . . . . . . . . . . . . . . . . .151 EHSS2 . . . . . . . . . . . . . . . . . . .151 GL GL GL GL GL GL . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 GLL9 DC . . . . . . . . . . . . . . . . .102 GLL9C . . . . . . . . . . . . . . . . . . .102 GLS 7C . . . . . . . . . . . . . . . . . . .102 GLS1 . . . . . . . . . . . . . . . . . . . .102 GLS10 . . . . . . . . . . . . . . . . . . . .102 GLS10 250 . . . . . . . . . . . . . . . .102 CG7545 CG7545 CG7545 CG7545 CG7545 CG7545 EHSS3 EHSS4 EHSS5 EHSS6 EHSS7 EHSS8 GLL1 . . . . . . . . . . . . . . . . . .85, 102 GLL1 DC . . . . . . . . . . . . . . . . .102 GLL10 . . . . . . . . . . . . . . . . .85, 102 GLL10 250 . . . . . . . . . . . . . . . .102 GLL10 250C . . . . . . . . . . . . . . .102 GLL10 DC . . . . . . . . . . . . . . . . .102 GLS10 250C . . . . . . . . . . . . . . .102 GLS10C . . . . . . . . . . . . . . . . . .102 GLS11 . . . . . . . . . . . . . . . . . . . .102 GLS11 250 . . . . . . . . . . . . . . . .102 GLS11 250C . . . . . . . . . . . . . . .102 GLS11C . . . . . . . . . . . . . . . . . .102 174 750 . . . . . . . . . . . . . .136 850 . . . . . . . . . . . . . .136 950 . . . . . . . . . . . . . .136 1050 . . . . . . . . . . . . .136 560 . . . . . . . . . . . . . .136 650 . . . . . . . . . . . . . .136 250 350 450 560 650 250 350 450 560 650 750 850 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 . . . . . . . . . . . . . . .136 250 350 450 560 650 750 . . . . . . . . . . . . . . . . . . .151 . . . . . . . . . . . . . . . . . . .151 . . . . . . . . . . . . . . . . . . .151 . . . . . . . . . . . . . . . . . . .151 . . . . . . . . . . . . . . . . . . .151 . . . . . . . . . . . . . . . . . . .151 US: 1-866-764-5454 CAN: 1-800-265-0502 15 16 17 18 19 20 . . . . . . . . . . . .116, . . . . . . . . . . . .116, . . . . . . . . . . . .116, . . . . . . . . . . . .116, . . . . . . . . . . . .116, . . . . . . . . . . . .116, Copyright© 2007 Cooper Crouse-Hinds Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page GLS12 . . . . . . . . . . . . . . . . . . .102 GLS12 250 . . . . . . . . . . . . . . . .102 GLS12 250C . . . . . . . . . . . . . . .102 GLS12C . . . . . . . . . . . . . . . . . .102 GLS1C . . . . . . . . . . . . . . . . . . .102 GLS2 . . . . . . . . . . . . . . . . . . . .102 H1037 . . . . . . . . . . . . . . . . . . . .104 H1037DC . . . . . . . . . . . . . . . . .104 H1038 . . . . . . . . . . . . . . . . . . . .104 H1038DC . . . . . . . . . . . . . . . . .104 H1039 . . . . . . . . . . . . . . . . . . . .104 H1039DC . . . . . . . . . . . . . . . . .104 HGLS10C . . . . . . . . . . . . . . . . .106 HGLS11 . . . . . . . . . . . . . . . .87, 106 HGLS11 250 . . . . . . . . . . . . . . .106 HGLS11 250C . . . . . . . . . . . . .106 HGLS11C . . . . . . . . . . . . . . . . .106 HGLS12 . . . . . . . . . . . . . . .87, 106 HUB6 . . . . . . . . . . . . . . .83, 87, 115 HUB7 . . . . . . . . . . . . . . .83, 87, 115 HUB8 . . . . . . . . . . . . . . .83, 87, 115 HUB9 . . . . . . . . . . . . . . .83, 87, 115 JCC1 . . . . . . . . . . . . . . . . . . . . .111 JCC2 . . . . . . . . . . . . . . . . . . . . .111 GLS2C . . . . . . . . . . . . . . . . . . .102 GLS3 . . . . . . . . . . . . . . . . . . . .102 GLS3C . . . . . . . . . . . . . . . . . . .102 GLS4 . . . . . . . . . . . . . . . . . . . .102 GLS4 10 . . . . . . . . . . . . . . . . . .102 GLS4 10C . . . . . . . . . . . . . . . . .102 H1040 . . . . . . . . . . . . . . . . . . . .104 H1040DC . . . . . . . . . . . . . . . . .104 H1041 . . . . . . . . . . . . . . . . . . . .104 H1042 . . . . . . . . . . . . . . . . . . . .104 HGLL 1 . . . . . . . . . . . . . . . . . . .104 HGLL 10 . . . . . . . . . . . . . . . . . .104 HGLS12 250 . . . . . . . . . . . . . . .106 HGLS12 250C . . . . . . . . . . . . .106 HGLS12C . . . . . . . . . . . . . . . . .106 HGLS1C . . . . . . . . . . . . . . . . . .106 HGLS2 . . . . . . . . . . . . . . . . . . .106 HGLS2C . . . . . . . . . . . . . . . . . .106 JCC34 . . . . . . . . . . . . . . . . . . . .111 JCC56 . . . . . . . . . . . . . . . . . . . .111 JCC78 . . . . . . . . . . . . . . . . . . . .111 JCC910 . . . . . . . . . . . . . . . . . . .111 K100CM . . . . . . . . . . . . . . . . . .121 K100S . . . . . . . . . . . . . . . . . . . .121 GLS4C . . . . . . . . . . . . . . . . . . .102 GLS5 . . . . . . . . . . . . . . . . . . . .102 GLS5 10 . . . . . . . . . . . . . . . . . .102 GLS5 10C . . . . . . . . . . . . . . . . .102 GLS5C . . . . . . . . . . . . . . . . . . .102 GLS6 . . . . . . . . . . . . . . . . . . . .102 HGLL HGLL HGLL HGLL HGLL HGLL 11 . . . . . . . . . . . . . . . . . .104 11 250 . . . . . . . . . . . . . .104 11C . . . . . . . . . . . . . . . . .104 12 . . . . . . . . . . . . . . . . . .104 12 250 . . . . . . . . . . . . . .104 12 250C . . . . . . . . . . . . .104 HGLS3 . . . . . . . . . . . . . . . . . . .106 HGLS3C . . . . . . . . . . . . . . . . . .106 HGLS4 . . . . . . . . . . . . . . . . . . .106 HGLS4 10 . . . . . . . . . . . . . . . . .106 HGLS4 10C . . . . . . . . . . . . . . .106 HGLS4C . . . . . . . . . . . . . . . . . .106 K100SG . . . . . . . . . . . . . . . . . .121 K125CM . . . . . . . . . . . . . . . . . .121 K125S . . . . . . . . . . . . . . . . . . . .121 K125SG . . . . . . . . . . . . . . . . . .121 K200CM . . . . . . . . . . . . . . . . . .121 K200S . . . . . . . . . . . . . . . . . . . .121 GLS6 10 . . . . . . . . . . . . . . . . . .102 GLS6 10C . . . . . . . . . . . . . . . . .102 GLS6C . . . . . . . . . . . . . . . . . . .102 GLS7 . . . . . . . . . . . . . . . . . . . .102 GLS7 250 . . . . . . . . . . . . . . . . .102 GLS7 250C . . . . . . . . . . . . . . . .102 HGLL HGLL HGLL HGLL HGLL HGLL 12C . . . . . . . . . . . . . . . . .104 2 . . . . . . . . . . . . . . . . . . .104 3 . . . . . . . . . . . . . . . . . . .104 4 . . . . . . . . . . . . . . . . . . .104 5 . . . . . . . . . . . . . . . . . . .104 6 . . . . . . . . . . . . . . . . . . .104 HGLS5 . . . . . . . . . . . . . . . . . . .106 HGLS5 10 . . . . . . . . . . . . . . . . .106 HGLS5 10C . . . . . . . . . . . . . . .106 HGLS5C . . . . . . . . . . . . . . . . . .106 HGLS6 . . . . . . . . . . . . . . . . . . .106 HGLS6 10 . . . . . . . . . . . . . . . . .106 K200SG . . . . . . . . . . . . . . . . . .121 K250CM . . . . . . . . . . . . . . . . . .121 K250S . . . . . . . . . . . . . . . . . . . .121 K250SG . . . . . . . . . . . . . . . . . .121 K350CM . . . . . . . . . . . . . . . . . .121 K350S . . . . . . . . . . . . . . . . . . . .121 GLS7 GLS7 GLS8 GLS8 GLS8 GLS8 30 . . . . . . . . . . . . . . . . . .102 30C . . . . . . . . . . . . . . . . .102 . . . . . . . . . . . . . . . . . . . .102 250 . . . . . . . . . . . . . . . . .102 250C . . . . . . . . . . . . . . . .102 30 . . . . . . . . . . . . . . . . . .102 HGLL 6C . . . . . . . . . . . . . . . . .104 HGLL 7 . . . . . . . . . . . . . . . . . . .104 HGLL 8 . . . . . . . . . . . . . . . . . . .104 HGLL 9 . . . . . . . . . . . . . . . . . . .104 HGLL10 250 . . . . . . . . . . . . . . .104 HGLL10 250C . . . . . . . . . . . . . .104 HGLS6 10C . . . . . . . . . . . . . . .106 HGLS6C . . . . . . . . . . . . . . . . . .106 HGLS7 . . . . . . . . . . . . . . . . . . .106 HGLS7 250 . . . . . . . . . . . . . . . .106 HGLS7 250C . . . . . . . . . . . . . .106 HGLS7 30 . . . . . . . . . . . . . . . . .106 K350SG . . . . . . . . . . . . . . . . . .121 K50CM . . . . . . . . . . . . . . . . . . .121 K50S . . . . . . . . . . . . . . . . . . . . .121 K50SG . . . . . . . . . . . . . . . . . . .121 K75CM . . . . . . . . . . . . . . . . . . .121 K75S . . . . . . . . . . . . . . . . . . . . .121 GLS8 30C . . . . . . . . . . . . . . . . .102 GLS8C . . . . . . . . . . . . . . . . . . .102 GLS9 . . . . . . . . . . . . . . . . . . . .102 GLS9 250 . . . . . . . . . . . . . . . . .102 GLS9 250C . . . . . . . . . . . . . . . .102 GLS9C . . . . . . . . . . . . . . . . . . .102 HGLL10C . . . . . . . . . . . . . . . . .104 HGLL11 250C . . . . . . . . . . . . . .104 HGLL1C . . . . . . . . . . . . . . . . . .104 HGLL2C . . . . . . . . . . . . . . . . . .104 HGLL3C . . . . . . . . . . . . . . . . . .104 HGLL4 10 . . . . . . . . . . . . . . . . .104 HGLS7 30C . . . . . . . . . . . . . . .106 HGLS7C . . . . . . . . . . . . . . .87, 106 HGLS8 . . . . . . . . . . . . . . . . . . .106 HGLS8 250 . . . . . . . . . . . . . . . .106 HGLS8 250C . . . . . . . . . . . . . .106 HGLS8 30 . . . . . . . . . . . . . . . . .106 K75SG . . . . . . . . . . . . . . . . . . .121 LB100M . . . . . . . . . . . . . . . . . .121 LB105 . . . . . . . . . . . . . . . . . . . .117 LB105 MT . . . . . . . . . . . . . . . . .116 LB125M . . . . . . . . . . . . . . . . . .121 LB15 . . . . . . . . . . . . . . . . . . . . .117 H H H H H H 931 932 933 934 935 936 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 HGLL4 10C . . . . . . . . . . . . . . . .104 HGLL4C . . . . . . . . . . . . . . . . . .104 HGLL5 10 . . . . . . . . . . . . . . . . .104 HGLL5 10C . . . . . . . . . . . . . . . .104 HGLL5C . . . . . . . . . . . . . . . . . .104 HGLL6 10 . . . . . . . . . . . . . . . . .104 HGLS8 30C . . . . . . . . . . . . . . .106 HGLS8C . . . . . . . . . . . . . . . . . .106 HGLS9 . . . . . . . . . . . . . . . . . . .106 HGLS9 250 . . . . . . . . . . . . . . . .106 HGLS9 250C . . . . . . . . . . . . . .106 HGLS9C . . . . . . . . . . . . . . . . . .106 LB15 MT . . . . . . . . . . . . . . . . . .116 LB150M . . . . . . . . . . . . . . . . . .121 LB200M . . . . . . . . . . . . . . . . . .121 LB25 . . . . . . . . . . . . . . . . . . . . .117 LB25 MT . . . . . . . . . . . . . . . . . .116 LB250M . . . . . . . . . . . . . . . . . .121 H H H H H H 937 938 939 940 941 942 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . . .104 HGLL6 10C . . . . . . . . . . . . . . . .104 HGLL7 250 . . . . . . . . . . . . . . . .104 HGLL7 250C . . . . . . . . . . . . . .104 HGLL7 30 . . . . . . . . . . . . . . . . .104 HGLL7 30C . . . . . . . . . . . . . . .104 HGLL7C . . . . . . . . . . . . . . . . . .104 HS1031 HS1032 HS1033 HS1034 HS1035 HS1036 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 LB300M . . . . . . . . . . . . . . . . . .121 LB35 . . . . . . . . . . . . . . . . . . . . .117 LB35 MT . . . . . . . . . . . . . . . . . .116 LB350M . . . . . . . . . . . . . . . . . .121 LB400M . . . . . . . . . . . . . . . . . .121 LB45 . . . . . . . . . . . . . . . . . . . . .117 H1031 . . . . . . . . . . . . . . . . . . . .104 H1031DC . . . . . . . . . . . . . . . . .104 H1032 . . . . . . . . . . . . . . . . . . . .104 H1032DC . . . . . . . . . . . . . . . . .104 H1033 . . . . . . . . . . . . . . . . . . . .104 H1033DC . . . . . . . . . . . . . . . . .104 HGLL8 250 . . . . . . . . . . . . . . . .104 HGLL8 250C . . . . . . . . . . . . . .104 HGLL8 30 . . . . . . . . . . . . . . . . .104 HGLL8 30C . . . . . . . . . . . . . . .104 HGLL8C . . . . . . . . . . . . . . . . . .104 HGLL9 250 . . . . . . . . . . . . . . . .104 HS1037 HS1038 HS1039 HS1040 HS1041 HS1042 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 . . . . . . . . . . . . . . . . . . .104 LB45 MT . . . . . . . . . . . . . . . . . .116 LB50M . . . . . . . . . . . . . . . . . . .121 LB55 . . . . . . . . . . . . . . . . . . . . .117 LB55 MT . . . . . . . . . . . . . . . . . .116 LB65 . . . . . . . . . . . . . . . . . . . . .117 LB65 MT . . . . . . . . . . . . . . . . . .116 H1034 . . . . . . . . . . . . . . . . . . . .104 H1034DC . . . . . . . . . . . . . . . . .104 H1035 . . . . . . . . . . . . . . . . . . . .104 H1035DC . . . . . . . . . . . . . . . . .104 H1036 . . . . . . . . . . . . . . . . . . . .104 H1036DC . . . . . . . . . . . . . . . . .104 HGLL9 250C . . . . . . . . . . . . . .104 HGLL9C . . . . . . . . . . . . . . . . . .104 HGLS1 . . . . . . . . . . . . . . . . . . .106 HGLS10 . . . . . . . . . . . . . . . . . .106 HGLS10 250 . . . . . . . . . . . . . . .106 HGLS10 250C . . . . . . . . . . . . .106 HUB1 . . . . . . . . . . . . . . . . .83, HUB10 . . . . . . . . . . . . . . . .83, HUB2 . . . . . . . . . . . . . . . . .83, HUB3 . . . . . . . . . . . . . . .83, 87, HUB4 . . . . . . . . . . . . . . .83, 87, HUB5 . . . . . . . . . . . . . . .83, 87, US: 1-866-764-5454 CAN: 1-800-265-0502 115 115 115 115 115 115 Copyright© 2007 Cooper Crouse-Hinds LB75 . . . . . . . . . . . . . . . . . . . . .117 LB75 MT . . . . . . . . . . . . . . . . . .116 LB75M . . . . . . . . . . . . . . . . . . .121 LB85 . . . . . . . . . . . . . . . . . . . . .117 LB85 MT . . . . . . . . . . . . . . . . . .116 LB95 . . . . . . . . . . . . . . . . . . . . .117 175 Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page LB95 MT . . . . . . . . . . . . . . . . . .116 LL100M . . . . . . . . . . . . . . . . . . .121 LL105 . . . . . . . . . . . . . . . . . . . .117 LL125M . . . . . . . . . . . . . . . . . . .121 LL15 . . . . . . . . . . . . . . . . . . . . .117 LL15 MT . . . . . . . . . . . . . . . . . .116 LT10090G SA . . . . . . . . . . . . . .129 LT10090NM . . . . . . . . . . . . . . .135 LT100DC . . . . . . . . . . . . . . . . . .127 LT100G . . . . . . . . . . . . . . . . . . .128 LT100G SA . . . . . . . . . . . . . . . .128 LT100NM . . . . . . . . . . . . . . . . .135 LT35090 . . . . . . . . . . . . . . . . . .126 LT35090DC . . . . . . . . . . . . . . .127 LT35090G . . . . . . . . . . . . . . . . .129 LT350DC . . . . . . . . . . . . . . . . .127 LT350G . . . . . . . . . . . . . . . . . . .128 LT350G SA . . . . . . . . . . . . . . . .128 LTB10090 . . . . . . . . . . . . . . . . .126 LTB10090DC . . . . . . . . . . . . . .127 LTB10090G . . . . . . . . . . . . . . . .129 LTB10090GC . . . . . . . . . . . . . .129 LTB100DC . . . . . . . . . . . . . . . .127 LTB100G . . . . . . . . . . . . . . . . . .128 LL150M . . . . . . . . . . . . . . . . . . .121 LL200M . . . . . . . . . . . . . . . . . .121 LL25 . . . . . . . . . . . . . . . . . . . . .117 LL25 MT . . . . . . . . . . . . . . . . . .116 LL250M . . . . . . . . . . . . . . . . . .121 LL300M . . . . . . . . . . . . . . . . . .121 LT125 . . . . . . . . . . . . . . . . . . . .125 LT125 SA . . . . . . . . . . . . . . . . .126 LT12545 . . . . . . . . . . . . . . . . . .126 LT12590 . . . . . . . . . . . . . . . . . .126 LT12590 SA . . . . . . . . . . . . . . .126 LT12590DC . . . . . . . . . . . . . . . .127 LT38 . . . . . . . . . . . . . . . . . . . . .125 LT38 SA . . . . . . . . . . . . . . . . . .126 LT3845 . . . . . . . . . . . . . . . . . . .126 LT3890 . . . . . . . . . . . . . . . . . . .126 LT3890 SA . . . . . . . . . . . . . . . .126 LT3890DC . . . . . . . . . . . . . . . .127 LTB100GC . . . . . . . . . . . . . . . .129 LTB125 . . . . . . . . . . . . . . . . . . .125 LTB12545 . . . . . . . . . . . . . . . . .126 LTB12545G . . . . . . . . . . . . . . . .129 LTB12545GC . . . . . . . . . . . . . .129 LTB12590 . . . . . . . . . . . . . . . . .126 LL35 . . . . . . . . . . . . . . . . . . . . .117 LL35 MT . . . . . . . . . . . . . . . . . .116 LL350M . . . . . . . . . . . . . . . . . .121 LL400M . . . . . . . . . . . . . . . . . .121 LL45 . . . . . . . . . . . . . . . . . . . . .117 LL45 MT . . . . . . . . . . . . . . . . . .116 LT12590G . . . . . . . . . . . . . . . . .129 LT12590G SA . . . . . . . . . . . . . .129 LT125DC . . . . . . . . . . . . . . . . . .127 LT125G . . . . . . . . . . . . . . . . . . .128 LT125G SA . . . . . . . . . . . . . . . .128 LT150 . . . . . . . . . . . . . . . . . . . .125 LT3890G . . . . . . . . . . . . . . . . . .129 LT3890G SA . . . . . . . . . . . . . . .129 LT38DC . . . . . . . . . . . . . . . . . .127 LT38G . . . . . . . . . . . . . . . . . . . .128 LT38G SA . . . . . . . . . . . . . . . . .128 LT400 . . . . . . . . . . . . . . . . . . . .125 LTB12590DC . . . . . . . . . . . . . .127 LTB12590G . . . . . . . . . . . . . . . .129 LTB12590GC . . . . . . . . . . . . . .129 LTB125DC . . . . . . . . . . . . . . . .127 LTB125G . . . . . . . . . . . . . . . . . .128 LTB125GC . . . . . . . . . . . . . . . .129 LL50M . . . . . . . . . . . . . . . . . . .121 LL55 . . . . . . . . . . . . . . . . . . . . .117 LL55 MT . . . . . . . . . . . . . . . . . .116 LL65 . . . . . . . . . . . . . . . . . . . . .117 LL65 MT . . . . . . . . . . . . . . . . . .116 LL75 . . . . . . . . . . . . . . . . . . . . .117 LT150 SA . . . . . . . . . . . . . . . . .126 LT15045 . . . . . . . . . . . . . . . . . .126 LT15090 . . . . . . . . . . . . . . . . . .126 LT15090 SA . . . . . . . . . . . . . . .126 LT15090DC . . . . . . . . . . . . . . . .127 LT15090G . . . . . . . . . . . . . . . . .129 LT400 SA . . . . . . . . . . . . . . . . .126 LT40045 . . . . . . . . . . . . . . . . . .126 LT40090 . . . . . . . . . . . . . . . . . .126 LT40090DC . . . . . . . . . . . . . . .127 LT40090G . . . . . . . . . . . . . . . . .129 LT400DC . . . . . . . . . . . . . . . . .127 LTB150 . . . . . . . . . . . . . . . . . . .125 LTB15045 . . . . . . . . . . . . . . . . .126 LTB15045G . . . . . . . . . . . . . . . .129 LTB15045GC . . . . . . . . . . . . . .129 LTB15090 . . . . . . . . . . . . . . . . .126 LTB15090DC . . . . . . . . . . . . . .127 LL75M . . . . . . . . . . . . . . . . . . .121 LL85 . . . . . . . . . . . . . . . . . . . . .117 LL95 . . . . . . . . . . . . . . . . . . . . .117 LR100M . . . . . . . . . . . . . . . . . .121 LR105 . . . . . . . . . . . . . . . . . . . .117 LR125M . . . . . . . . . . . . . . . . . .121 LT15090G SA . . . . . . . . . . . . . .129 LT150DC . . . . . . . . . . . . . . . . . .127 LT150G . . . . . . . . . . . . . . . . . . .128 LT150G SA . . . . . . . . . . . . . . . .128 LT200 . . . . . . . . . . . . . . . . . . . .125 LT200 SA . . . . . . . . . . . . . . . . .126 LT400G . . . . . . . . . . . . . . . . . . .128 LT400G SA . . . . . . . . . . . . . . . .128 LT50 . . . . . . . . . . . . . . . . . . . . .125 LT50 SA . . . . . . . . . . . . . . . . . .126 LT500 . . . . . . . . . . . . . . . . . . . .125 LT500G . . . . . . . . . . . . . . . . . . .128 LTB15090G . . . . . . . . . . . . . . . .129 LTB15090GC . . . . . . . . . . . . . .129 LTB150DC . . . . . . . . . . . . . . . .127 LTB150G . . . . . . . . . . . . . . . . . .128 LTB150GC . . . . . . . . . . . . . . . .129 LTB200 . . . . . . . . . . . . . . . . . . .125 LR15 . . . . . . . . . . . . . . . . . . . . .117 LR15 MT . . . . . . . . . . . . . . . . . .116 LR150M . . . . . . . . . . . . . . . . . .121 LR200M . . . . . . . . . . . . . . . . . .121 LR25 . . . . . . . . . . . . . . . . . . . . .117 LR25 MT . . . . . . . . . . . . . . . . . .116 LT20045 . . . . . . . . . . . . . . . . . .126 LT20090 . . . . . . . . . . . . . . . . . .126 LT20090 SA . . . . . . . . . . . . . . .126 LT20090DC . . . . . . . . . . . . . . .127 LT20090G . . . . . . . . . . . . . . . . .129 LT20090G SA . . . . . . . . . . . . . .129 LT5045 . . . . . . . . . . . . . . . . . . .126 LT5090 . . . . . . . . . . . . . . . . . . .126 LT5090 SA . . . . . . . . . . . . . . . .126 LT5090DC . . . . . . . . . . . . . . . .127 LT5090G . . . . . . . . . . . . . . . . . .129 LT5090G SA . . . . . . . . . . . . . . .129 LTB20045 . . . . . . . . . . . . . . . . .126 LTB20045G . . . . . . . . . . . . . . .129 LTB20045GC . . . . . . . . . . . . . .129 LTB20090 . . . . . . . . . . . . . . . . .126 LTB20090DC . . . . . . . . . . . . . .127 LTB20090G . . . . . . . . . . . . . . .129 LR250M . . . . . . . . . . . . . . . . . .121 LR300M . . . . . . . . . . . . . . . . . .121 LR35 . . . . . . . . . . . . . . . . . . . . .117 LR35 MT . . . . . . . . . . . . . . . . . .116 LR350M . . . . . . . . . . . . . . . . . .121 LR400M . . . . . . . . . . . . . . . . . .121 LT200DC . . . . . . . . . . . . . . . . .127 LT200G . . . . . . . . . . . . . . . . . . .128 LT200G SA . . . . . . . . . . . . . . . .128 LT250 . . . . . . . . . . . . . . . . . . . .125 LT250 SA . . . . . . . . . . . . . . . . .126 LT25045 . . . . . . . . . . . . . . . . . .126 LT5090NM . . . . . . . . . . . . . . . .135 LT50DC . . . . . . . . . . . . . . . . . .127 LT50G . . . . . . . . . . . . . . . . . . . .128 LT50G SA . . . . . . . . . . . . . . . . .128 LT50NM . . . . . . . . . . . . . . . . . .135 LT600 . . . . . . . . . . . . . . . . . . . .125 LTB20090GC . . . . . . . . . . . . . .129 LTB200DC . . . . . . . . . . . . . . . .127 LTB200G . . . . . . . . . . . . . . . . .128 LTB200GC . . . . . . . . . . . . . . . .129 LTB250 . . . . . . . . . . . . . . . . . . .125 LTB25045 . . . . . . . . . . . . . . . . .126 LR45 . . . . . . . . . . . . . . . . . . . . .117 LR45 MT . . . . . . . . . . . . . . . . . .116 LR50M . . . . . . . . . . . . . . . . . . .121 LR55 . . . . . . . . . . . . . . . . . . . . .117 LR55 MT . . . . . . . . . . . . . . . . . .116 LR65 . . . . . . . . . . . . . . . . . . . . .117 LT25090 . . . . . . . . . . . . . . . . . .126 LT25090DC . . . . . . . . . . . . . . .127 LT25090G . . . . . . . . . . . . . . . . .129 LT250DC . . . . . . . . . . . . . . . . .127 LT250G . . . . . . . . . . . . . . . . . . .128 LT250G SA . . . . . . . . . . . . . . . .128 LT600G . . . . . . . . . . . . . . . . . . .128 LT75 . . . . . . . . . . . . . . . . . . . . .125 LT75 SA . . . . . . . . . . . . . . . . . .126 LT7545 . . . . . . . . . . . . . . . . . . .126 LT7590 . . . . . . . . . . . . . . . . . . .126 LT7590 SA . . . . . . . . . . . . . . . .126 LTB25045G . . . . . . . . . . . . . . .129 LTB25045GC . . . . . . . . . . . . . .129 LTB25090 . . . . . . . . . . . . . . . . .126 LTB25090DC . . . . . . . . . . . . . .127 LTB25090G . . . . . . . . . . . . . . .129 LTB25090GC . . . . . . . . . . . . . .129 LR65 MT . . . . . . . . . . . . . . . . . .116 LR75 . . . . . . . . . . . . . . . . . . . . .117 LR75M . . . . . . . . . . . . . . . . . . .121 LR85 . . . . . . . . . . . . . . . . . . . . .117 LR95 . . . . . . . . . . . . . . . . . . . . .117 LT100 . . . . . . . . . . . . . . . . . . . .125 LT300 . . . . . . . . . . . . . . . . . . . .125 LT300 SA . . . . . . . . . . . . . . . . .126 LT30045 . . . . . . . . . . . . . . . . . .126 LT30090 . . . . . . . . . . . . . . . . . .126 LT30090DC . . . . . . . . . . . . . . .127 LT30090G . . . . . . . . . . . . . . . . .129 LT7590DC . . . . . . . . . . . . . . . .127 LT7590G . . . . . . . . . . . . . . . . . .129 LT7590G SA . . . . . . . . . . . . . . .129 LT7590NM . . . . . . . . . . . . . . . .135 LT75DC . . . . . . . . . . . . . . . . . .127 LT75G . . . . . . . . . . . . . . . . . . . .128 LTB250DC . . . . . . . . . . . . . . . .127 LTB250G . . . . . . . . . . . . . . . . .128 LTB250GC . . . . . . . . . . . . . . . .129 LTB300 . . . . . . . . . . . . . . . . . . .125 LTB30045 . . . . . . . . . . . . . . . . .126 LTB30045G . . . . . . . . . . . . . . .129 LT100 SA . . . . . . . . . . . . . . . . .126 LT10045 . . . . . . . . . . . . . . . . . .126 LT10090 . . . . . . . . . . . . . . . . . .126 LT10090 SA . . . . . . . . . . . . . . .126 LT10090DC . . . . . . . . . . . . . . . .127 LT10090G . . . . . . . . . . . . . . . . .129 LT300DC . . . . . . . . . . . . . . . . .127 LT300G . . . . . . . . . . . . . . . . . . .128 LT300G SA . . . . . . . . . . . . . . . .128 LT350 . . . . . . . . . . . . . . . . . . . .125 LT350 SA . . . . . . . . . . . . . . . . .126 LT35045 . . . . . . . . . . . . . . . . . .126 LT75G SA . . . . . . . . . . . . . . . . .128 LT75NM . . . . . . . . . . . . . . . . . .135 LTB100 . . . . . . . . . . . . . . . . . . .125 LTB10045 . . . . . . . . . . . . . . . . .126 LTB10045G . . . . . . . . . . . . . . . .129 LTB10045GC . . . . . . . . . . . . . .129 LTB30045GC . . . . . . . . . . . . . .129 LTB30090 . . . . . . . . . . . . . . . . .126 LTB30090DC . . . . . . . . . . . . . .127 LTB30090G . . . . . . . . . . . . . . .129 LTB30090GC . . . . . . . . . . . . . .129 LTB300DC . . . . . . . . . . . . . . . .127 176 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page LTB300G . . . . . . . . . . . . . . . . .128 LTB300GC . . . . . . . . . . . . . . . .129 LTB350 . . . . . . . . . . . . . . . . . . .125 LTB35045 . . . . . . . . . . . . . . . . .126 LTB35045G . . . . . . . . . . . . . . .129 LTB35045GC . . . . . . . . . . . . . .129 LTB75GC . . . . . . . . . . . . . . . . .129 LTBK100 . . . . . . . . . . . . . . . . . .133 LTBK10045 . . . . . . . . . . . . . . . .133 LTBK10090 . . . . . . . . . . . . . . . .133 LTBK125 . . . . . . . . . . . . . . . . . .133 LTBK12545 . . . . . . . . . . . . . . . .133 LTQB200 . . . . . . . . . . . . . . . . .132 LTQB38 . . . . . . . . . . . . . . . . . .132 LTQB50 . . . . . . . . . . . . . . . . . .132 LTQB75 . . . . . . . . . . . . . . . . . .132 LTQF100 . . . . . . . . . . . . . . . . . .132 LTQF125 . . . . . . . . . . . . . . . . . .132 PLG1M . . . . . . . . . . . . . . . . . . .113 PLG25M . . . . . . . . . . . . . . . . . .113 PLG2M . . . . . . . . . . . . . . . . . . .113 PLG35M . . . . . . . . . . . . . . . . . .113 PLG3M . . . . . . . . . . . . . . . . . . .113 PLG45M . . . . . . . . . . . . . . . . . .113 LTB35090 . . . . . . . . . . . . . . . . .126 LTB35090DC . . . . . . . . . . . . . .127 LTB35090G . . . . . . . . . . . . . . .129 LTB35090GC . . . . . . . . . . . . . .129 LTB350DC . . . . . . . . . . . . . . . .127 LTB350G . . . . . . . . . . . . . . . . .128 LTBK12590 . . . . . . . . . . . . . . . .133 LTBK150 . . . . . . . . . . . . . . . . . .133 LTBK15045 . . . . . . . . . . . . . . . .133 LTBK15090 . . . . . . . . . . . . . . . .133 LTBK200 . . . . . . . . . . . . . . . . . .133 LTBK20045 . . . . . . . . . . . . . . . .133 LTQF150 . . . . . . . . . . . . . . . . . .132 LTQF200 . . . . . . . . . . . . . . . . . .132 LTQF38 . . . . . . . . . . . . . . . . . . .132 LTQF50 . . . . . . . . . . . . . . . . . . .132 LTQF75 . . . . . . . . . . . . . . . . . . .132 LTR100 . . . . . . . . . . . . . . . . . . .126 PLG4M . . . . . . . . . . . . . . . . . . .113 PLG55M . . . . . . . . . . . . . . . . . .113 PLG5M . . . . . . . . . . . . . . . . . . .113 PLG65M . . . . . . . . . . . . . . . . . .113 PLG6M . . . . . . . . . . . . . . . . . . .113 PLG75M . . . . . . . . . . . . . . . . . .113 LTB350GC . . . . . . . . . . . . . . . .129 LTB38 . . . . . . . . . . . . . . . . . . . .125 LTB3845 . . . . . . . . . . . . . . . . . .126 LTB3845G . . . . . . . . . . . . . . . .129 LTB3845GC . . . . . . . . . . . . . . .129 LTB3890 . . . . . . . . . . . . . . . . . .126 LTBK20090 . . . . . . . . . . . . . . . .133 LTBK38 . . . . . . . . . . . . . . . . . . .133 LTBK3845 . . . . . . . . . . . . . . . . .133 LTBK3890 . . . . . . . . . . . . . . . . .133 LTBK50 . . . . . . . . . . . . . . . . . . .133 LTBK5045 . . . . . . . . . . . . . . . . .133 LTR100G . . . . . . . . . . . . . . . . .131 LTR125 . . . . . . . . . . . . . . . . . . .126 LTR125G . . . . . . . . . . . . . . . . .131 LTR150 . . . . . . . . . . . . . . . . . . .126 LTR150G . . . . . . . . . . . . . . . . .131 LTR200 . . . . . . . . . . . . . . . . . . .126 PLG7M . . . . . . . . . . . . . . . . . . .113 PLG85M . . . . . . . . . . . . . . . . . .113 PLG8M . . . . . . . . . . . . . . . . . . .113 PLG95M . . . . . . . . . . . . . . . . . .113 PLG9M . . . . . . . . . . . . . . . . . . .113 PPC 100 . . . . . . . . . . . . . . . . . .108 LTB3890DC . . . . . . . . . . . . . . .127 LTB3890G . . . . . . . . . . . . . . . .129 LTB3890GC . . . . . . . . . . . . . . .129 LTB38DC . . . . . . . . . . . . . . . . .127 LTB38G . . . . . . . . . . . . . . . . . .128 LTB38GC . . . . . . . . . . . . . . . . .129 LTBK5090 . . . . . . . . . . . . . . . . .133 LTBK75 . . . . . . . . . . . . . . . . . . .133 LTBK7545 . . . . . . . . . . . . . . . . .133 LTBK7590 . . . . . . . . . . . . . . . . .133 LTK100 . . . . . . . . . . . . . . . . . . .133 LTK10045 . . . . . . . . . . . . . . . . .133 LTR200G . . . . . . . . . . . . . . . . .131 LTR38 . . . . . . . . . . . . . . . . . . . .126 LTR38G . . . . . . . . . . . . . . . . . .131 LTR50 . . . . . . . . . . . . . . . . . . . .126 LTR50G . . . . . . . . . . . . . . . . . .131 LTR75 . . . . . . . . . . . . . . . . . . . .126 PPC PPC PPC PPC PPC PPC LTB400 . . . . . . . . . . . . . . . . . . .125 LTB40045 . . . . . . . . . . . . . . . . .126 LTB40045G . . . . . . . . . . . . . . .129 LTB40045GC . . . . . . . . . . . . . .129 LTB40090 . . . . . . . . . . . . . . . . .126 LTB40090DC . . . . . . . . . . . . . .127 LTK10090 . . . . . . . . . . . . . . . . .133 LTK125 . . . . . . . . . . . . . . . . . . .133 LTK12545 . . . . . . . . . . . . . . . . .133 LTK12590 . . . . . . . . . . . . . . . . .133 LTK150 . . . . . . . . . . . . . . . . . . .133 LTK15045 . . . . . . . . . . . . . . . . .133 LTR75G . . . . . . . . . . . . . . . . . .131 MHUB1 . . . . . . . . . . . . . . . .87, 115 MHUB10 . . . . . . . . . . . . . . .87, 115 MHUB11 . . . . . . . . . . . . . . .87, 115 MHUB12 . . . . . . . . . . . . . . .87, 115 MHUB2 . . . . . . . . . . . . . . . .87, 115 PPC 400 . . . . . . . . . . . . . . . . . .108 PPC 50 . . . . . . . . . . . . . . . . . . .108 PPC 75 . . . . . . . . . . . . . . . . . . .108 QLK50D . . . . . . . . . . . . . .141, 145 QLK50S . . . . . . . . . . . . . .141, 145 QLK75 . . . . . . . . . . . . . . .141, 145 LTB40090G . . . . . . . . . . . . . . .129 LTB40090GC . . . . . . . . . . . . . .129 LTB400DC . . . . . . . . . . . . . . . .127 LTB400G . . . . . . . . . . . . . . . . .128 LTB400GC . . . . . . . . . . . . . . . .129 LTB50 . . . . . . . . . . . . . . . . . . . .125 LTK15090 . . . . . . . . . . . . . . . . .133 LTK200 . . . . . . . . . . . . . . . . . . .133 LTK20045 . . . . . . . . . . . . . . . . .133 LTK20090 . . . . . . . . . . . . . . . . .133 LTK38 . . . . . . . . . . . . . . . . . . . .133 LTK3845 . . . . . . . . . . . . . . . . . .133 MHUB3 MHUB4 MHUB5 MHUB6 MHUB7 MHUB8 RAC100HD RAC125HD RAC150HD RAC200HD RAC250HD RAC300HD LTB500 . . . . . . . . . . . . . . . . . . .125 LTB500G . . . . . . . . . . . . . . . . .128 LTB5045 . . . . . . . . . . . . . . . . . .126 LTB5045G . . . . . . . . . . . . . . . .129 LTB5045GC . . . . . . . . . . . . . . .129 LTB5090 . . . . . . . . . . . . . . . . . .126 LTK3890 . . . . . . . . . . . . . . . . . .133 LTK50 . . . . . . . . . . . . . . . . . . . .133 LTK5045 . . . . . . . . . . . . . . . . . .133 LTK5090 . . . . . . . . . . . . . . . . . .133 LTK75 . . . . . . . . . . . . . . . . . . . .133 LTK7545 . . . . . . . . . . . . . . . . . .133 MHUB9 . . . . . . . . . . . . . . . .87, 115 NCG100 100 . . . . . . . . . . . . . . .136 NCG38 35 . . . . . . . . . . . . . . . .136 NCG50 50 . . . . . . . . . . . . . . . .136 NCG75 75 . . . . . . . . . . . . . . . .136 NS 1 . . . . . . . . . . . . . . . . . .95, 109 RAC350HD . . . . . . . . . . . . . . . .111 RAC400HD . . . . . . . . . . . . . . . .111 RAC50HD . . . . . . . . . . . . . . . . .111 RAC75HD . . . . . . . . . . . . . . . . .111 S 1 1/2 . . . . . . . . . . . . . . . . .74, 88 S 1 3/8 . . . . . . . . . . . . . . . . .74, 88 LTB5090DC . . . . . . . . . . . . . . .127 LTB5090G . . . . . . . . . . . . . . . .129 LTB5090GC . . . . . . . . . . . . . . .129 LTB50DC . . . . . . . . . . . . . . . . .127 LTB50G . . . . . . . . . . . . . . . . . .128 LTB50GC . . . . . . . . . . . . . . . . .129 LTK7590 . . . . . . . . . . . . . . . . . .133 LTKF100 . . . . . . . . . . . . . . . . . .133 LTKF125 . . . . . . . . . . . . . . . . . .133 LTKF150 . . . . . . . . . . . . . . . . . .133 LTKF200 . . . . . . . . . . . . . . . . . .133 LTKF38 . . . . . . . . . . . . . . . . . . .133 NS 2 . . . . . . . . . . . . . . . . . .95, 109 NS 3 . . . . . . . . . . . . . . . . . .95, 109 NSS1 . . . . . . . . . . . . . . . . .95, 109 NSS2 . . . . . . . . . . . . . . . . .95, 109 NSS3 . . . . . . . . . . . . . . . . .95, 109 PARC100HD . . . . . . . . . . . . . . .111 S1031 S1032 S1033 S1034 S1035 S1036 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 LTB600 . . . . . . . . . . . . . . . . . . .125 LTB600G . . . . . . . . . . . . . . . . .128 LTB75 . . . . . . . . . . . . . . . . . . . .125 LTB7545 . . . . . . . . . . . . . . . . . .126 LTB7545G . . . . . . . . . . . . . . . .129 LTB7545GC . . . . . . . . . . . . . . .129 LTKF50 LTKF75 LTQ100 LTQ125 LTQ150 LTQ200 PARC125HD PARC150HD PARC200HD PARC250HD PARC300HD PARC350HD S1037 S1038 S1039 S1040 S1041 S1042 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 . . . . . . . . . . . . . . . . . . . .100 LTB7590 . . . . . . . . . . . . . . . . . .126 LTB7590DC . . . . . . . . . . . . . . .127 LTB7590G . . . . . . . . . . . . . . . .129 LTB7590GC . . . . . . . . . . . . . . .129 LTB75DC . . . . . . . . . . . . . . . . .127 LTB75G . . . . . . . . . . . . . . . . . .128 LTQ38 . . . . . . . . . . . . . . . . . . . .132 LTQ50 . . . . . . . . . . . . . . . . . . . .132 LTQ75 . . . . . . . . . . . . . . . . . . . .132 LTQB100 . . . . . . . . . . . . . . . . . .132 LTQB125 . . . . . . . . . . . . . . . . . .132 LTQB150 . . . . . . . . . . . . . . . . . .132 . . . . . . . . . . . . . . . . . . .133 . . . . . . . . . . . . . . . . . . .133 . . . . . . . . . . . . . . . . . . .132 . . . . . . . . . . . . . . . . . . .132 . . . . . . . . . . . . . . . . . . .132 . . . . . . . . . . . . . . . . . . .132 US: 1-866-764-5454 CAN: 1-800-265-0502 . . . . . . . . . . . . . . . .87, . . . . . . . . . . . . . . . .87, . . . . . . . . . . . . . . . .87, . . . . . . . . . . . . . . . .87, . . . . . . . . . . . . . . . .87, . . . . . . . . . . . . . . . .87, 115 115 115 115 115 115 . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . .111 PARC400HD . . . . . . . . . . . . . . .111 PARC50HD . . . . . . . . . . . . . . . .111 PARC75HD . . . . . . . . . . . . . . . .111 PLG105M . . . . . . . . . . . . . . . . .113 PLG10M . . . . . . . . . . . . . . . . . .113 PLG15M . . . . . . . . . . . . . . . . . .113 Copyright© 2007 Cooper Crouse-Hinds 125 150 200 250 300 350 . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . . . .108 . . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . . .111 . . . . . . . . . . . . . . . .111 SA 1W . . . . . . . . . . . . . . . . .74, 88 SG1 . . . . . . . . . . . . . . . . . . . . .126 SG10 . . . . . . . . . . . . . . . . . . . .126 SG11 . . . . . . . . . . . . . . . . . . . . .126 SG12 . . . . . . . . . . . . . . . . . . . .126 SG2 . . . . . . . . . . . . . . . . . . . . .126 177 Catalog Number SG3 SG4 SG5 SG6 SG7 SG8 Page Catalog Number Page Catalog Number Page Catalog Number Page . . . . . . . . . . . . . . . . . . . . .126 . . . . . . . . . . . . . . . . . . . . .126 . . . . . . . . . . . . . . . . . . . . .126 . . . . . . . . . . . . . . . . . . . . .126 . . . . . . . . . . . . . . . . . . . . .126 . . . . . . . . . . . . . . . . . . . . .126 SSTG 5 . . . . . . . . . . . . . . . . . . .81 SSTG 6 . . . . . . . . . . . . . . . . . . .81 SSTG 7 . . . . . . . . . . . . . . . . . . .81 SSTG 8 . . . . . . . . . . . . . . . . . . .81 SSTG 9 . . . . . . . . . . . . . . . . . . .81 SSTGK 1 . . . . . . . . . . . . . . . . . .82 STAGN 2 . . . . . . . . . . . . . . . . . .82 STAGN 3 . . . . . . . . . . . . . . . . . .82 STAGN 4 . . . . . . . . . . . . . . . . . .82 STAGN 5 . . . . . . . . . . . . . . . . . .82 STAGN 6 . . . . . . . . . . . . . . . . . .82 STC 1 . . . . . . . . . . . . . . . . . . . . .82 STTTB 2 . . . . . . . . . . . . . . . . . . .83 STTTB 3 . . . . . . . . . . . . . . . . . . .83 STTTB 4 . . . . . . . . . . . . . . . . . . .83 STTTB 5 . . . . . . . . . . . . . . . . . . .83 STTTB 6 . . . . . . . . . . . . . . . . . . .83 STTTBA 1 . . . . . . . . . . . . . . . . .83 SG9 . . . . . . . . . . . . . . . . . . . . .126 SL1 . . . . . . . . . . . . . . . . . . . . . .124 SL10 . . . . . . . . . . . . . . . . . . . . .124 SL11 . . . . . . . . . . . . . . . . . . . . .124 SL12 . . . . . . . . . . . . . . . . . . . . .124 SL2 . . . . . . . . . . . . . . . . . . . . . .124 SSTGK 2 . . . . . . . . . . . . . . . . . .82 SSTGK 3 . . . . . . . . . . . . . . . . . .82 SSTGK 4 . . . . . . . . . . . . . . . . . .82 SSTGK 5 . . . . . . . . . . . . . . . . . .82 SSTGK 6 . . . . . . . . . . . . . . . . . .82 SSTM 1 . . . . . . . . . . . . . . . . . . .83 STC 2 STC 3 STC 4 STC 5 STC 6 STG 1 . . . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . . . .82 STTTBA 2 . . . . . . . . . . . . . . . . .83 STTTBA 3 . . . . . . . . . . . . . . . . .83 STTTBA 4 . . . . . . . . . . . . . . . . .83 STTTBA 5 . . . . . . . . . . . . . . . . .83 STTTBA 6 . . . . . . . . . . . . . . . . .83 T100M . . . . . . . . . . . . . . . . . . .121 SL3 SL4 SL5 SL6 SL7 SL8 SSTM SSTM SSTM SSTM SSTM ST 03 STG STG STG STG STG STG 10 . . . . . . . . . . . . . . . . . . . .82 11 . . . . . . . . . . . . . . . . . . . .82 12 . . . . . . . . . . . . . . . . . . . .82 2 . . . . . . . . . . . . . . . . . . . . .82 3 . . . . . . . . . . . . . . . . . . . . .82 4 . . . . . . . . . . . . . . . . . . . . .82 T105 . . . . . . . . . . . . . . . . . . . . .117 T125M . . . . . . . . . . . . . . . . . . .121 T15 . . . . . . . . . . . . . . . . . . . . . .117 T15 MT . . . . . . . . . . . . . . . . . . .116 T150M . . . . . . . . . . . . . . . . . . .121 T200M . . . . . . . . . . . . . . . . . . .121 . . . . . . . . . . . . . . . . . . . . . .124 . . . . . . . . . . . . . . . . . . . . . .124 . . . . . . . . . . . . . . . . . . . . . .124 . . . . . . . . . . . . . . . . . . . . . .124 . . . . . . . . . . . . . . . . . . . . . .124 . . . . . . . . . . . . . . . . . . . . . .124 2 . . . . . . . . . . . . . . . . . . .83 3 . . . . . . . . . . . . . . . . . . .83 4 . . . . . . . . . . . . . . . . . . .83 5 . . . . . . . . . . . . . . . . . . .83 6 . . . . . . . . . . . . . . . . . . .83 . . . . . . . . . . . . . . . . . . . . .81 SL9 . . . . . . . . . . . . . . . . . . . . . .124 SLB1 . . . . . . . . . . . . . . . . . . . . .151 SLB2 . . . . . . . . . . . . . . . . . . . . .151 SLB3 . . . . . . . . . . . . . . . . . . . . .151 SLB4 . . . . . . . . . . . . . . . . . . . . .151 SLB5 . . . . . . . . . . . . . . . . . . . . .151 ST ST ST ST ST ST 1 . . . . . . . . . . . . . . . . . . . . . .81 10 . . . . . . . . . . . . . . . . . . . . .81 11 . . . . . . . . . . . . . . . . . . . . .81 12 . . . . . . . . . . . . . . . . . . . . .81 2 . . . . . . . . . . . . . . . . . . . . . .81 3 . . . . . . . . . . . . . . . . . . . . . .81 STG 5 . . . . . . . . . . . . . . . . . . . . .82 STG 6 . . . . . . . . . . . . . . . . . . . . .82 STG 7 . . . . . . . . . . . . . . . . . . . . .82 STG 8 . . . . . . . . . . . . . . . . . . . . .82 STG 9 . . . . . . . . . . . . . . . . . . . . .82 STGK 1 . . . . . . . . . . . . . . . . . . .82 T25 . . . . . . . . . . . . . . . . . . . . . .117 T25 MT . . . . . . . . . . . . . . . . . . .116 T250M . . . . . . . . . . . . . . . . . . .121 T300M . . . . . . . . . . . . . . . . . . .121 T35 . . . . . . . . . . . . . . . . . . . . . .117 T35 MT . . . . . . . . . . . . . . . . . . .116 SLB6 . . . . . . . . . . . . . . . . . . . . .151 SSACB100 . . . . . . . . . . . .140, 143 SSACB38 . . . . . . . . . . . . .140, 143 SSACB50 . . . . . . . . . . . . .140, 143 SSACB75 . . . . . . . . . . . . .140, 143 SSBC100 . . . . . . . . . . . . . . . . . .91 ST ST ST ST ST ST 4 5 6 7 8 9 STGK 2 STGK 3 STGK 4 STGK 5 STGK 6 STGN 1 . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . .82 T350M . . . . . . . . . . . . . . . . . . .121 T400M . . . . . . . . . . . . . . . . . . .121 T45 . . . . . . . . . . . . . . . . . . . . . .117 T45 MT . . . . . . . . . . . . . . . . . . .116 T50M . . . . . . . . . . . . . . . . . . . .121 T55 . . . . . . . . . . . . . . . . . . . . . .117 SSBC50 . . . . . . . . . . . . . . . . . . .91 SSBC75 . . . . . . . . . . . . . . . . . . .91 SSC100 . . . . . . . . . . . . . . . . . . .91 SSC50 . . . . . . . . . . . . . . . . . . . .91 SSC75 . . . . . . . . . . . . . . . . . . . .91 SSR1 . . . . . . . . . . . . . . . . . . . . .99 STA STA STA STA STA STA 1 . . . . . . . . . . . . . . . . . . . . .81 10 . . . . . . . . . . . . . . . . . . . .81 11 . . . . . . . . . . . . . . . . . . . .81 12 . . . . . . . . . . . . . . . . . . . .81 2 . . . . . . . . . . . . . . . . . . . . .81 3 . . . . . . . . . . . . . . . . . . . . .81 STGN 2 . . . . . . . . . . . . . . . . . . .82 STGN 3 . . . . . . . . . . . . . . . . . . .82 STGN 4 . . . . . . . . . . . . . . . . . . .82 STGN 5 . . . . . . . . . . . . . . . . . . .82 STGN 6 . . . . . . . . . . . . . . . . . . .82 STM 1 . . . . . . . . . . . . . . . . . . . . .83 T55 MT . . . . . . . . . . . . . . . . . . .116 T65 . . . . . . . . . . . . . . . . . . . . . .117 T65 MT . . . . . . . . . . . . . . . . . . .116 T75 . . . . . . . . . . . . . . . . . . . . . .117 T75M . . . . . . . . . . . . . . . . . . . .121 T85 . . . . . . . . . . . . . . . . . . . . . .117 SSR11 SSR12 SSR13 SSR14 SSR15 SSR16 STA STA STA STA STA STA 4 5 6 7 8 9 STM 2 . . . . . . . . . . . . . . . . . . . . .83 STM 3 . . . . . . . . . . . . . . . . . . . . .83 STM 4 . . . . . . . . . . . . . . . . . . . . .83 STM 5 . . . . . . . . . . . . . . . . . . . . .83 STM 6 . . . . . . . . . . . . . . . . . . . . .83 STTB 1 . . . . . . . . . . . . . . . . . . . .82 T95 . . . . . . . . . . . . . . . . . . . . . .117 TB100M . . . . . . . . . . . . . . . . . .121 TB125M . . . . . . . . . . . . . . . . . .121 TB150M . . . . . . . . . . . . . . . . . .121 TB200M . . . . . . . . . . . . . . . . . .121 TB50M . . . . . . . . . . . . . . . . . . .121 TB75M . . . . . . . . . . . . . . . . . . .121 TCC1 . . . . . . . . . . . . . . . . . . . .114 TCC10 . . . . . . . . . . . . . . . . . . . .114 TCC12 . . . . . . . . . . . . . . . . . . . .114 TCC14 . . . . . . . . . . . . . . . . . . . .114 TCC2 . . . . . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . . . . . .99 . . . . . . . . . . . . . . . . . . . .99 . . . . . . . . . . . . . . . . . . . .99 . . . . . . . . . . . . . . . . . . . .99 . . . . . . . . . . . . . . . . . . . .99 . . . . . . . . . . . . . . . . . . . .99 . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . .81 . . . . . . . . . . . . . . . . . . . . .81 SSR2 . . . . . . . . . . . . . . . . . . . . .99 SSR21 . . . . . . . . . . . . . . . . . . . .99 SSR22 . . . . . . . . . . . . . . . . . . . .99 SSR23 . . . . . . . . . . . . . . . . . . . .99 SSR24 . . . . . . . . . . . . . . . . . . . .99 SSR25 . . . . . . . . . . . . . . . . . . . .99 STAC 1 . . . . . . . . . . . . . . . . . . . .82 STAC 1CD . . . . . . . . . . . . . . . . .83 STAC 1ST . . . . . . . . . . . . . . . . . .83 STAC 2 . . . . . . . . . . . . . . . . . . . .82 STAC 3 . . . . . . . . . . . . . . . . . . . .82 STAG 1 . . . . . . . . . . . . . . . . . . . .82 STTB STTB STTB STTB STTB STTB SSR26 . . . . . . . . . . . . . . . . . . . .99 SSR3 . . . . . . . . . . . . . . . . . . . . .99 SSR4 . . . . . . . . . . . . . . . . . . . . .99 SSR5 . . . . . . . . . . . . . . . . . . . . .99 SSR6 . . . . . . . . . . . . . . . . . . . . .99 SSTC 1 . . . . . . . . . . . . . . . . . . . .83 STAG STAG STAG STAG STAG STAG STTB 7 . . . . . . . . . . . . . . . . . . . .82 STTB 8 . . . . . . . . . . . . . . . . . . . .82 STTB 9 . . . . . . . . . . . . . . . . . . . .82 STTBA 1 . . . . . . . . . . . . . . . . . . .83 STTBA 2 . . . . . . . . . . . . . . . . . . .83 STTBA 3 . . . . . . . . . . . . . . . . . . .83 TCC3 TCC4 TCC5 TCC6 TCC7 TCC8 SSTC 1CD . . . . . . . . . . . . . . . . .83 SSTG 1 . . . . . . . . . . . . . . . . . . .81 SSTG 10 . . . . . . . . . . . . . . . . . . .81 SSTG 2 . . . . . . . . . . . . . . . . . . .81 SSTG 3 . . . . . . . . . . . . . . . . . . .81 SSTG 4 . . . . . . . . . . . . . . . . . . .81 STAG 5 . . . . . . . . . . . . . . . . . . . .82 STAG 6 . . . . . . . . . . . . . . . . . . . .82 STAG 7 . . . . . . . . . . . . . . . . . . . .82 STAG 8 . . . . . . . . . . . . . . . . . . . .82 STAG 9 . . . . . . . . . . . . . . . . . . . .82 STAGN 1 . . . . . . . . . . . . . . . . . .82 STTBA 4 STTBA 5 STTBA 6 STTBA 7 STTBA 8 STTTB 1 TCC9 . . . . . . . . . . . . . . . . . . . .114 TP100 . . . . . . . . . . . . . . . . . . . . .11 TP1000 . . . . . . . . . . . . . . . . . . . .52 TP1009 . . . . . . . . . . . . . . . . . . . .52 TP101 . . . . . . . . . . . . . . . . . . . . .11 TP1010 . . . . . . . . . . . . . . . . . . . .52 178 10 . . . . . . . . . . . . . . . . . . .82 11 . . . . . . . . . . . . . . . . . . .82 12 . . . . . . . . . . . . . . . . . . .82 2 . . . . . . . . . . . . . . . . . . . .82 3 . . . . . . . . . . . . . . . . . . . .82 4 . . . . . . . . . . . . . . . . . . . .82 US: 1-866-764-5454 CAN: 1-800-265-0502 10 . . . . . . . . . . . . . . . . . . .82 2 . . . . . . . . . . . . . . . . . . . .82 3 . . . . . . . . . . . . . . . . . . . .82 4 . . . . . . . . . . . . . . . . . . . .82 5 . . . . . . . . . . . . . . . . . . . .82 6 . . . . . . . . . . . . . . . . . . . .82 . . . . . . . . . . . . . . . . . . .83 . . . . . . . . . . . . . . . . . . .83 . . . . . . . . . . . . . . . . . . .83 . . . . . . . . . . . . . . . . . . .83 . . . . . . . . . . . . . . . . . . .83 . . . . . . . . . . . . . . . . . . .83 Copyright© 2007 Cooper Crouse-Hinds . . . . . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . . . . . .114 Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page TP1013 . . . . . . . . . . . . . . . . . . . .52 TP1014 . . . . . . . . . . . . . . . . . . . .52 TP1020 . . . . . . . . . . . . . . . . . . . .52 TP1023 . . . . . . . . . . . . . . . . . . . .52 TP1024 . . . . . . . . . . . . . . . . . . . .52 TP103 . . . . . . . . . . . . . . . . . . . . .11 TP1690 . . . . . . . . . . . . . . . . . . . .52 TP170 . . . . . . . . . . . . . . . . . . . . .11 TP171 . . . . . . . . . . . . . . . . . . . . .11 TP172 . . . . . . . . . . . . . . . . . . . . .11 TP174 . . . . . . . . . . . . . . . . . . . . .11 TP177 . . . . . . . . . . . . . . . . . . . . .15 TP270 TP272 TP273 TP274 TP275 TP276 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .28 . . . . . . . . . . . . . . . . . . . . .23 TP331 TP332 TP333 TP334 TP335 TP336 TP104 . . . . . . . . . . . . . . . . . . . . .11 TP1040 . . . . . . . . . . . . . . . . . . . .52 TP1045 . . . . . . . . . . . . . . . . . . . .52 TP106 . . . . . . . . . . . . . . . . . . . . .11 TP114 . . . . . . . . . . . . . . . . . . . . .11 TP115 . . . . . . . . . . . . . . . . . . . . .11 TP178 . . . . . . . . . . . . . . . . . . . . .15 TP179 . . . . . . . . . . . . . . . . . . . . .15 TP180 . . . . . . . . . . . . . . . . . . . . .15 TP1800 . . . . . . . . . . . . . . . . . . . .52 TP1802 . . . . . . . . . . . . . . . . . . . .56 TP1832 . . . . . . . . . . . . . . . . . . . .56 TP278 TP280 TP282 TP284 TP286 TP288 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 TP338 . . . . . . . . . . . . . . . . . . . . .23 TP339 . . . . . . . . . . . . . . . . . . . . .23 TP348 . . . . . . . . . . . . . . . . . . . . .48 TP3490 . . . . . . . . . . . . . . . . . . . .52 TP35000 . . . . . . . . . . . . . . . . . . .37 TP354 . . . . . . . . . . . . . . . . . . . . .27 TP116 TP118 TP120 TP123 TP124 TP126 . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . .11 . . . . . . . . . . . . . . . . . . . . .11 TP184 . . . . . . . . . . . . . . . . . . . . .15 TP185 . . . . . . . . . . . . . . . . . . . . .15 TP188 . . . . . . . . . . . . . . . . . . . . .15 TP190 . . . . . . . . . . . . . . . . . . . . .15 TP1900 . . . . . . . . . . . . . . . . . . . .52 TP1930 . . . . . . . . . . . . . . . . . . . .52 TP290 . . . . . . . . . . . . . . . . . . . . .23 TP292 . . . . . . . . . . . . . . . . . . . . .23 TP294 . . . . . . . . . . . . . . . . . . . . .23 TP298 . . . . . . . . . . . . . . . . . . . . .23 TP300 . . . . . . . . . . . . . . . . . . . . .23 TP30000 . . . . . . . . . . . . . . . . . . .37 TP35403PF . . . . . . . . . . . . . . . .38 TP35404PF . . . . . . . . . . . . . . . .38 TP35414 . . . . . . . . . . . . . . . . . . .38 TP35431 . . . . . . . . . . . . . . . . . . .38 TP35434 . . . . . . . . . . . . . . . . . . .38 TP35454 . . . . . . . . . . . . . . . . . . .38 TP130 . . . . . . . . . . . . . . . . . . . . .11 TP1300 . . . . . . . . . . . . . . . . . . . .28 TP1300 1 . . . . . . . . . . . . . . . . . .28 TP131 . . . . . . . . . . . . . . . . . . . . .11 TP132 . . . . . . . . . . . . . . . . . . . . .11 TP134 . . . . . . . . . . . . . . . . . . . . .11 TP196 . . . . . . . . . . . . . . . . . . . . .15 TP2000 . . . . . . . . . . . . . . . . . . . .52 TP2002 . . . . . . . . . . . . . . . . . . . .56 TP2020 . . . . . . . . . . . . . . . . . . . .52 TP2030 . . . . . . . . . . . . . . . . . . . .52 TP206 . . . . . . . . . . . . . . . . . . . . .15 TP301 . . . . . . . . . . . . . . . . . . . . .28 TP302 . . . . . . . . . . . . . . . . . . . . .23 TP304 . . . . . . . . . . . . . . . . . . . . .23 TP30403PF . . . . . . . . . . . . . . . .38 TP30404PF . . . . . . . . . . . . . . . .38 TP30414 . . . . . . . . . . . . . . . . . . .38 TP356 . . . . . . . . . . . . . . . . . . . . .27 TP3600 . . . . . . . . . . . . . . . . . . . .52 TP36000 . . . . . . . . . . . . . . . . . . .37 TP3602 . . . . . . . . . . . . . . . . . . . .56 TP3630 . . . . . . . . . . . . . . . . . . . .52 TP3632 . . . . . . . . . . . . . . . . . . . .56 TP137 . . . . . . . . . . . . . . . . . . . . .11 TP138 . . . . . . . . . . . . . . . . . . . . .11 TP158 . . . . . . . . . . . . . . . . . . . . .11 TP1600 . . . . . . . . . . . . . . . . . . . .52 TP16002 . . . . . . . . . . . . . . . . . . .57 TP16003 . . . . . . . . . . . . . . . . . . .57 TP210 TP213 TP214 TP216 TP217 TP218 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 TP30431 . . . . . . . . . . . . . . . . . . .38 TP30434 . . . . . . . . . . . . . . . . . . .38 TP30454 . . . . . . . . . . . . . . . . . . .38 TP306 . . . . . . . . . . . . . . . . . . . . .23 TP308 . . . . . . . . . . . . . . . . . . . . .23 TP310 . . . . . . . . . . . . . . . . . . . . .23 TP3635 . . . . . . . . . . . . . . . . . . . .52 TP36403PF . . . . . . . . . . . . . . . .38 TP36404PF . . . . . . . . . . . . . . . .38 TP36414 . . . . . . . . . . . . . . . . . . .38 TP36431 . . . . . . . . . . . . . . . . . . .38 TP36434 . . . . . . . . . . . . . . . . . . .38 TP16007 TP16008 TP16012 TP16013 TP16022 TP16023 . . . . . . . . . . . . . . . . . . .57 . . . . . . . . . . . . . . . . . . .57 . . . . . . . . . . . . . . . . . . .57 . . . . . . . . . . . . . . . . . . .57 . . . . . . . . . . . . . . . . . . .57 . . . . . . . . . . . . . . . . . . .57 TP220 . . . . . . . . . . . . . . . . . . . . .15 TP222 . . . . . . . . . . . . . . . . . . . . .15 TP224 . . . . . . . . . . . . . . . . . . . . .15 TP226 . . . . . . . . . . . . . . . . . . . . .18 TP2300 . . . . . . . . . . . . . . . . . . . .52 TP2302 . . . . . . . . . . . . . . . . . . . .56 TP31000 . . . . . . . . . . . . . . . . . . .37 TP312 . . . . . . . . . . . . . . . . . . . . .23 TP314 . . . . . . . . . . . . . . . . . . . . .23 TP31403PF . . . . . . . . . . . . . . . .38 TP31404PF . . . . . . . . . . . . . . . .38 TP31414 . . . . . . . . . . . . . . . . . . .38 TP36454 . . . . . . . . . . . . . . . . . . .38 TP36467PF . . . . . . . . . . . . . . . .38 TP368 . . . . . . . . . . . . . . . . . . . . .28 TP37000 . . . . . . . . . . . . . . . . . . .37 TP372 . . . . . . . . . . . . . . . . . . . . .28 TP37403PF . . . . . . . . . . . . . . . .38 TP16098 . . . . . . . . . . . . . . . . . . .57 TP16099 . . . . . . . . . . . . . . . . . . .57 TP161 . . . . . . . . . . . . . . . . . . . . .11 TP16107 . . . . . . . . . . . . . . . . . . .57 TP16108 . . . . . . . . . . . . . . . . . . .57 TP16110 . . . . . . . . . . . . . . . . . . .57 TP2332 . . . . . . . . . . . . . . . . . . . .56 TP236 . . . . . . . . . . . . . . . . . . . . .18 TP238 . . . . . . . . . . . . . . . . . . . . .18 TP239 . . . . . . . . . . . . . . . . . . . . .18 TP240 . . . . . . . . . . . . . . . . . . . . .18 TP242 . . . . . . . . . . . . . . . . . . . . .18 TP31431 . . . . . . . . . . . . . . . . . . .38 TP31434 . . . . . . . . . . . . . . . . . . .38 TP31436PF . . . . . . . . . . . . . . . .38 TP31454 . . . . . . . . . . . . . . . . . . .38 TP31467PF . . . . . . . . . . . . . . . .38 TP315 . . . . . . . . . . . . . . . . . . . . .28 TP37404PF . . . . . . . . . . . . . . . .38 TP37414 . . . . . . . . . . . . . . . . . . .38 TP37431 . . . . . . . . . . . . . . . . . . .38 TP37434 . . . . . . . . . . . . . . . . . . .38 TP37454 . . . . . . . . . . . . . . . . . . .38 TP376 . . . . . . . . . . . . . . . . . . . . .28 TP16111 . . . . . . . . . . . . . . . . . . .57 TP16112 . . . . . . . . . . . . . . . . . . .57 TP16113 . . . . . . . . . . . . . . . . . . .57 TP16122 . . . . . . . . . . . . . . . . . . .57 TP16123 . . . . . . . . . . . . . . . . . . .57 TP162 . . . . . . . . . . . . . . . . . . . . .11 TP243 TP244 TP246 TP248 TP249 TP250 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 TP316 . . . . . . . . . . . . . . . . . . . . .23 TP317 . . . . . . . . . . . . . . . . . . . . .23 TP318 . . . . . . . . . . . . . . . . . . . . .23 TP320 . . . . . . . . . . . . . . . . . . . . .23 TP32000 . . . . . . . . . . . . . . . . . . .37 TP322 . . . . . . . . . . . . . . . . . . . . .27 TP377 TP379 TP391 TP393 TP395 TP403 TP16200 . . . . . . . . . . . . . . . . . . .57 TP16201 . . . . . . . . . . . . . . . . . . .57 TP163 . . . . . . . . . . . . . . . . . . . . .11 TP16307 . . . . . . . . . . . . . . . . . . .57 TP16308 . . . . . . . . . . . . . . . . . . .57 TP16310 . . . . . . . . . . . . . . . . . . .57 TP252 TP254 TP256 TP258 TP259 TP260 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 TP323 . . . . . . . . . . . . . . . . . . . . .27 TP32403PF . . . . . . . . . . . . . . . .38 TP32404PF . . . . . . . . . . . . . . . .38 TP32414 . . . . . . . . . . . . . . . . . . .38 TP32431 . . . . . . . . . . . . . . . . . . .38 TP32434 . . . . . . . . . . . . . . . . . . .38 TP403 PF . . . . . . . . . . . . . . . . . .30 TP403SSB . . . . . . . . . . . . . . . . .36 TP404 . . . . . . . . . . . . . . . . . . . . .30 TP404 PF . . . . . . . . . . . . . . . . . .30 TP404SSB . . . . . . . . . . . . . . . . .36 TP405 . . . . . . . . . . . . . . . . . . . . .30 TP16311 . . . . . . . . . . . . . . . . . . .57 TP16317 . . . . . . . . . . . . . . . . . . .57 TP16318 . . . . . . . . . . . . . . . . . . .57 TP164 . . . . . . . . . . . . . . . . . . . . .11 TP16511 . . . . . . . . . . . . . . . .28, 57 TP168 . . . . . . . . . . . . . . . . . . . . .11 TP261 TP262 TP264 TP266 TP267 TP269 . . . . . . . . . . . . . . . . . . . . .28 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .23 TP32454 . . . . . . . . . . . . . . . . . . .38 TP32454PF . . . . . . . . . . . . . . . .38 TP326 . . . . . . . . . . . . . . . . . . . . .27 TP328 . . . . . . . . . . . . . . . . . . . . .27 TP329 . . . . . . . . . . . . . . . . . . . . .27 TP330 . . . . . . . . . . . . . . . . . . . . .27 TP408 TP410 TP412 TP414 TP418 TP422 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .28 . . . . . . . . . . . . . . . . . . . . .28 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .35 179 Catalog Number TP423 TP424 TP425 TP426 TP428 TP431 Page Catalog Number Page Catalog Number Page Catalog Number Page . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .35 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .35 . . . . . . . . . . . . . . . . . . . . .35 . . . . . . . . . . . . . . . . . . . . .30 TP507 TP508 TP509 TP510 TP511 TP512 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 TP590 TP591 TP592 TP593 TP594 TP595 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 TP678 TP680 TP682 TP683 TP684 TP685 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 TP431SSB . . . . . . . . . . . . . . . . .36 TP432 . . . . . . . . . . . . . . . . . . . . .30 TP434 . . . . . . . . . . . . . . . . . . . . .30 TP436 . . . . . . . . . . . . . . . . . . . . .30 TP437 . . . . . . . . . . . . . . . . . . . . .30 TP438 . . . . . . . . . . . . . . . . . . . . .30 TP513 TP514 TP515 TP516 TP517 TP518 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 TP596 TP598 TP600 TP602 TP604 TP606 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .47 TP686 TP687 TP690 TP691 TP692 TP693 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 TP440 . . . . . . . . . . . . . . . . . . . . .30 TP444 . . . . . . . . . . . . . . . . . . . . .30 TP444SSB . . . . . . . . . . . . . . . . .36 TP445 . . . . . . . . . . . . . . . . . . . . .30 TP446 . . . . . . . . . . . . . . . . . . . . .30 TP449 . . . . . . . . . . . . . . . . . . . . .30 TP519 TP520 TP522 TP524 TP526 TP528 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 TP608 . . . . . . . . . . . . . . . . . . . . .47 TP610 . . . . . . . . . . . . . . . . . . . . .47 TP6100 . . . . . . . . . . . . . . . . . . . .52 TP6102 . . . . . . . . . . . . . . . . . . . .56 TP612 . . . . . . . . . . . . . . . . . . . . .47 TP613 . . . . . . . . . . . . . . . . . . . . .47 TP694 . . . . . . . . . . . . . . . . . . . . .49 TP695 . . . . . . . . . . . . . . . . . . . . .49 TP700 . . . . . . . . . . . . . . . . . . . . .21 TP701 . . . . . . . . . . . . . . . . . . . . .21 TP7010 . . . . . . . . . . . . . . . . . . . .59 TP7011 . . . . . . . . . . . . . . . . . . . .59 TP450 . . . . . . . . . . . . . . . . . . . . .30 TP450SSB . . . . . . . . . . . . . . . . .36 TP451 . . . . . . . . . . . . . . . . . . . . .30 TP452 . . . . . . . . . . . . . . . . . . . . .30 TP454 . . . . . . . . . . . . . . . . . . . . .30 TP454SSB . . . . . . . . . . . . . . . . .36 TP529 TP530 TP531 TP532 TP534 TP536 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 TP6132 . . . . . . . . . . . . . . . . . . . .56 TP6135 . . . . . . . . . . . . . . . . . . . .52 TP614 . . . . . . . . . . . . . . . . . . . . .47 TP616 . . . . . . . . . . . . . . . . . . . . .47 TP618 . . . . . . . . . . . . . . . . . . . . .47 TP6180 . . . . . . . . . . . . . . . . . . . .52 TP7012 . . . . . . . . . . . . . . . . . . . .59 TP7018 . . . . . . . . . . . . . . . . . . . .59 TP702 . . . . . . . . . . . . . . . . . . . . .21 TP7026 . . . . . . . . . . . . . . . . . . . .59 TP703 . . . . . . . . . . . . . . . . . . . . .21 TP7034 . . . . . . . . . . . . . . . . . . . .59 TP456 . . . . . . . . . . . . . . . . . . . . .30 TP459 . . . . . . . . . . . . . . . . . . . . .30 TP4600 . . . . . . . . . . . . . . . . . . . .52 TP4602 . . . . . . . . . . . . . . . . . . . .56 TP461 . . . . . . . . . . . . . . . . . . . . .30 TP4630 . . . . . . . . . . . . . . . . . . . .52 TP538 TP540 TP541 TP542 TP543 TP548 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .42 TP620 TP622 TP623 TP624 TP628 TP629 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .50 TP704 . . . . . . . . . . . . . . . . . . . . .21 TP7042 . . . . . . . . . . . . . . . . . . . .59 TP705 . . . . . . . . . . . . . . . . . . . . .21 TP7050 . . . . . . . . . . . . . . . . . . . .59 TP7058 . . . . . . . . . . . . . . . . . . . .59 TP706 . . . . . . . . . . . . . . . . . . . . .21 TP4632 . . . . . . . . . . . . . . . . . . . .56 TP4635 . . . . . . . . . . . . . . . . . . . .52 TP467 . . . . . . . . . . . . . . . . . . . . .30 TP469 . . . . . . . . . . . . . . . . . . . . .30 TP472 . . . . . . . . . . . . . . . . . . . . .40 TP473 . . . . . . . . . . . . . . . . . . . . .40 TP549 TP550 TP554 TP556 TP557 TP558 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 TP630 TP631 TP632 TP633 TP635 TP636 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .48 TP7066 . . . . . . . . . . . . . . . . . . . .59 TP707 . . . . . . . . . . . . . . . . . . . . .21 TP7071 . . . . . . . . . . . . . . . . . . . .59 TP7074 . . . . . . . . . . . . . . . . . . . .59 TP7078 . . . . . . . . . . . . . . . . . . . .59 TP708 . . . . . . . . . . . . . . . . . . . . .21 TP474 TP475 TP476 TP477 TP478 TP479 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 TP560 . . . . . . . . . . . . . . . . . . . . .42 TP562 . . . . . . . . . . . . . . . . . . . . .42 TP563 . . . . . . . . . . . . . . . . . . . . .42 TP563SSB . . . . . . . . . . . . . . . . .36 TP564 . . . . . . . . . . . . . . . . . . . . .42 TP568 . . . . . . . . . . . . . . . . . . . . .45 TP640 TP641 TP644 TP647 TP648 TP649 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .48 TP7082 . . . . . . . . . . . . . . . . . . . .59 TP7086 . . . . . . . . . . . . . . . . . . . .59 TP7087 . . . . . . . . . . . . . . . . . . . .59 TP7088 . . . . . . . . . . . . . . . . . . . .59 TP709 . . . . . . . . . . . . . . . . . . . . .21 TP7090 . . . . . . . . . . . . . . . . . . . .59 TP480 TP482 TP483 TP484 TP486 TP488 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 TP569 TP570 TP571 TP572 TP573 TP574 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 TP650 TP651 TP652 TP653 TP655 TP657 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .21 . . . . . . . . . . . . . . . . . . . . .48 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .51 TP7094 . . . . . . . . . . . . . . . . . . . .59 TP7098 . . . . . . . . . . . . . . . . . . . .59 TP710 . . . . . . . . . . . . . . . . . . . . .37 TP7102 . . . . . . . . . . . . . . . . . . . .59 TP7106 . . . . . . . . . . . . . . . . . . . .59 TP7110 . . . . . . . . . . . . . . . . . . . .59 TP489 TP490 TP494 TP496 TP498 TP499 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 TP575 TP576 TP578 TP579 TP580 TP582 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 TP659 TP660 TP661 TP662 TP664 TP667 . . . . . . . . . . . . . . . . . . . . .21 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .51 TP7114 TP7118 TP7120 TP7122 TP7123 TP7126 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 TP500 TP501 TP502 TP503 TP504 TP506 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .40 TP583 TP584 TP586 TP587 TP588 TP589 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .47 . . . . . . . . . . . . . . . . . . . . .45 TP668 TP670 TP672 TP674 TP676 TP677 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .15 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 . . . . . . . . . . . . . . . . . . . . .18 TP7130 TP7134 TP7137 TP7138 TP7142 TP7143 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 180 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page TP7144 TP7146 TP7147 TP7148 TP7149 TP7150 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 TP7298 . . . . . . . . . . . . . . . . . . . .62 TP730 . . . . . . . . . . . . . . . . . . . . .45 TP7300 . . . . . . . . . . . . . . . . . . . .62 TP7301 . . . . . . . . . . . . . . . . . . . .62 TP7302 . . . . . . . . . . . . . . . . . . . .62 TP7308 . . . . . . . . . . . . . . . . . . . .62 TP7620 TP7621 TP7630 TP7640 TP7650 TP7660 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 TP872 TP873 TP874 TP876 TP877 TP900 TP7151 TP7152 TP7158 TP7159 TP7160 TP7162 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . .59, 62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .66 TP7309 TP7310 TP7312 TP7313 TP7314 TP7316 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 TP7670 TP7680 TP7800 TP7801 TP7805 TP7810 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . .72, 76 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . .72, 76 TP901 . . . . . . . . . . . . . . . . . . . . .21 TP902 . . . . . . . . . . . . . . . . . . . . .21 TPFSS . . . . . . . . . . . . . . . . . . . .56 TPRFH12 . . . . . . . . . . . . . . .74, 88 TPSFH12 . . . . . . . . . . . . . . .74, 88 UBM100HD . . . . . . . . . . . . . . . .114 TP7163 TP7164 TP7165 TP7166 TP7170 TP7173 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .59 TP7317 . . . . . . . . . . . . . . . . . . . .62 TP7318 . . . . . . . . . . . . . . . . . . . .62 TP732 . . . . . . . . . . . . . . . . . . . . .45 TP7320 . . . . . . . . . . . . . . . . . . . .62 TP7321 . . . . . . . . . . . . . . . . . . . .62 TP7322 . . . . . . . . . . . . . . . . . . . .62 TP7811 TP7815 TP7820 TP7825 TP7830 TP7835 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . .72, 76 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . .72, 76 . . . . . . . . . . . . . . . . . . . .72 UBM125HD UBM150HD UBM200HD UBM250HD UBM300HD UBM350HD TP7174 TP7176 TP7178 TP7186 TP7188 TP7199 . . . . . . . . . . . . . . . . . . . .59 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .66 . . . . . . . . . . . . . . . . . . . .62 TP7330 . . . . . . . . . . . . . . . . . . . .66 TP7331 . . . . . . . . . . . . . . . . . . . .66 TP7332 . . . . . . . . . . . . . . . . . . . .66 TP734 . . . . . . . . . . . . . . . . . . . . .45 TP736 . . . . . . . . . . . . . . . . . . . . .45 TP738 . . . . . . . . . . . . . . . . . . . . .45 TP7840 TP7860 TP7870 TP7920 TP7924 TP7925 . . . . . . . . . . . . . . . . .72, 76 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .75 . . . . . . . . . . . . . . . . . . . .75 . . . . . . . . . . . . . . . . . . . .75 UBM400HD . . . . . . . . . . . . . . . .114 UBM50HD . . . . . . . . . . . . . . . . .114 UBM75HD . . . . . . . . . . . . . . . . .114 WAB040402 . . . . . . . . . . . . . . .159 WAB040403 . . . . . . . . . . . . . . .159 WAB040404 . . . . . . . . . . . . . . .159 TP720 . . . . . . . . . . . . . . . . . . . . .45 TP7202 . . . . . . . . . . . . . . . . . . . .62 TP7206 . . . . . . . . . . . . . . . . . . . .62 TP7207 . . . . . . . . . . . . . . . . . . . .62 TP7208 . . . . . . . . . . . . . . . . . . . .62 TP7209 . . . . . . . . . . . . . . . . . . . .62 TP741 . . . . . . . . . . . . . . . . . . . . .45 TP7440 . . . . . . . . . . . . . . . . . . . .72 TP7441 . . . . . . . . . . . . . . . . . . . .72 TP7442 . . . . . . . . . . . . . . . . . . . .72 TP7443 . . . . . . . . . . . . . . . . . . . .72 TP7445 . . . . . . . . . . . . . . . . . . . .72 TP7927 . . . . . . . . . . . . . . . . . . . .75 TP7928 . . . . . . . . . . . . . . . . . . . .75 TP7940 . . . . . . . . . . . . . . . . .62, 75 TP7942 . . . . . . . . . . . . . . . . .62, 75 TP7944 . . . . . . . . . . . . . . . . .62, 75 TP802 . . . . . . . . . . . . . . . . . . . . .51 WAB050503 WAB050504 WAB060403 WAB060404 WAB060603 WAB060604 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 TP7214 . . . . . . . . . . . . . . . . . . . .62 TP7218 . . . . . . . . . . . . . . . . . . . .62 TP722 . . . . . . . . . . . . . . . . . . . . .45 TP7220 . . . . . . . . . . . . . . . . . . . .62 TP7224 . . . . . . . . . . . . . . . . . . . .62 TP7228 . . . . . . . . . . . . . . . . . . . .62 TP7446 TP7447 TP7448 TP7450 TP7451 TP7460 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 TP803 TP804 TP805 TP806 TP820 TP821 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .51 . . . . . . . . . . . . . . . . . . . . .49 . . . . . . . . . . . . . . . . . . . . .49 WAB060606 WAB080403 WAB080604 WAB080606 WAB080804 WAB080806 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 TP7232 . . . . . . . . . . . . . . . . . . . .62 TP7233 . . . . . . . . . . . . . . . . . . . .62 TP7236 . . . . . . . . . . . . . . . . . . . .62 TP7237 . . . . . . . . . . . . . . . . . . . .62 TP7238 . . . . . . . . . . . . . . . . . . . .62 TP724 . . . . . . . . . . . . . . . . . . . . .45 TP7462 TP7463 TP7464 TP7466 TP7468 TP7469 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 TP830 TP831 TP832 TP833 TP834 TP835 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .35 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .42 WAB080808 WAB090604 WAB100604 WAB100804 WAB100806 WAB101006 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 TP7240 TP7241 TP7242 TP7244 TP7248 TP7252 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 TP7470 TP7471 TP7472 TP7474 TP7475 TP7476 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 TP836 TP837 TP838 TP839 TP840 TP841 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .23 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .30 . . . . . . . . . . . . . . . . . . . . .35 WAB120604 WAB120606 WAB120806 WAB120808 WAB121204 WAB121206 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 TP726 . . . . . . . . . . . . . . . . . . . . .45 TP7260 . . . . . . . . . . . . . . . . . . . .62 TP7268 . . . . . . . . . . . . . . . . . . . .62 TP7272 . . . . . . . . . . . . . . . . . . . .62 TP7276 . . . . . . . . . . . . . . . . . . . .62 TP728 . . . . . . . . . . . . . . . . . . . . .45 TP7477 TP7478 TP7490 TP7495 TP7496 TP7497 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 TP842 TP850 TP851 TP852 TP853 TP854 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .40 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .45 . . . . . . . . . . . . . . . . . . . . .27 . . . . . . . . . . . . . . . . . . . . .40 WAB121208 WAB160606 WAB161208 WAB181206 WAB181208 WAB181210 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 TP7280 TP7292 TP7293 TP7294 TP7296 TP7297 TP7498 TP7499 TP7600 TP7601 TP7610 TP7611 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 . . . . . . . . . . . . . . . . . . . .72 TP860 TP861 TP862 TP863 TP870 TP871 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .42 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 WAB181806 WAB181812 WAB241212 WAB242408 WCB040402 WCB040403 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .159 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 . . . . . . . . . . . . . . . . . . . .62 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .50 . . . . . . . . . . . . . . . . . . . . .21 . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . .114 . . . . . . . . . . . . . . . .114 181 Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page WCB040404 WCB050503 WCB050504 WCB060403 WCB060404 WCB060603 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 WJB080604 WJB080606 WJB080804 WJB080806 WJB080808 WJB100806 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF120606 WJBF120806 WJBF120808 WJBF120810 WJBF121206 WJBF121208 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLFLSF 3 . . . . . . . . . . . . . . . . .70 WLFLSF 4 . . . . . . . . . . . . . . . . .70 WLFLWG 3 . . . . . . . . . . . . . . . . .70 WLFLWG 4 . . . . . . . . . . . . . . . . .70 WLPG100HPS/MT . . . . . . . . . . .67 WLPG100HPS/TT . . . . . . . . . . .67 WCB060604 WCB060606 WCB080403 WCB080604 WCB080606 WCB080804 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 WJB100808 WJB101006 WJB101008 WJB120606 WJB120806 WJB120808 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF121212 WJBF121218 WJBF140806 WJBF141410 WJBF161206 WJBF161208 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLPG100MH/MT . . . . . . . . . . . .67 WLPG100MH/TT . . . . . . . . . . . .67 WLPG150HPS/MT . . . . . . . . . . .67 WLPG150HPS/TT . . . . . . . . . . .67 WLPG175MH/MT . . . . . . . . . . . .67 WLPG175MH/TT . . . . . . . . . . . .67 WCB080806 WCB080808 WCB090604 WCB100604 WCB100804 WCB100806 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 WJB120810 WJB121206 WJB121208 WJB121212 WJB121218 WJB140806 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF161606 WJBF180806 WJBF180808 WJBF181006 WJBF181206 WJBF181208 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLPG70HPS/MT . . . . . . . . . . . .67 WLPG70HPS/TT . . . . . . . . . . . .67 WLPG70MH/MT . . . . . . . . . . . . .67 WLPG70MH/TT . . . . . . . . . . . . .67 WLWP100HPS/MT . . . . . . . . . . .67 WLWP100HPS/TT . . . . . . . . . . .67 WCB101006 WCB120604 WCB120606 WCB120806 WCB120808 WCB121204 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 WJB141410 WJB161206 WJB161208 WJB161606 WJB180806 WJB180808 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF181210 WJBF181212 WJBF181218 WJBF181806 WJBF181808 WJBF181812 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLWP100MH/MT . . . . . . . . . . . .67 WLWP100MH/TT . . . . . . . . . . . .67 WLWP150HPS/MT . . . . . . . . . . .67 WLWP150HPS/TT . . . . . . . . . . .67 WLWP175MH/MT . . . . . . . . . . . .67 WLWP175MH/TT . . . . . . . . . . . .67 WCB121206 WCB121208 WCB160606 WCB161208 WCB181206 WCB181208 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 WJB181006 WJB181206 WJB181208 WJB181210 WJB181212 WJB181218 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF181818 WJBF241208 WJBF241212 WJBF241808 WJBF241810 WJBF241812 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLWP250HPS/MT . . . . . . . . . . .67 WLWP250HPS/TT . . . . . . . . . . .67 WLWP250MH/MT . . . . . . . . . . . .67 WLWP250MH/MT S828 . . . . . . .67 WLWP250MH/TT . . . . . . . . . . . .67 WLWP400HPS/MT . . . . . . . . . . .67 WCB181210 WCB181806 WCB181812 WCB241212 WCB242408 WEB040403 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .160 . . . . . . . . . . . . . . .163 WJB181806 WJB181808 WJB181812 WJB181818 WJB241208 WJB241212 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF241818 WJBF242412 WJBF242418 WJBF242424 WJBF302412 WJBF302418 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLWP400HPS/TT . . . . . . . . . . .67 WLWP400MH/MT . . . . . . . . . . . .67 WLWP400MH/MT S828 . . . . . . .67 WLWP400MH/TT . . . . . . . . . . . .67 WLWPMP 1 . . . . . . . . . . . . . . . .70 WLWPWG 1 . . . . . . . . . . . . . . . .70 WEB040404 WEB060604 WEB060606 WEB080804 WEB080806 WEB121206 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 WJB241808 WJB241810 WJB241812 WJB241818 WJB242412 WJB242418 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF362418 . . . . . . . . . . . . . .162 WJBF362424 . . . . . . . . . . . . . .162 WLFL1000HPS/MT . . . . . . . . . .67 WLFL1000HPS/TT . . . . . . . . . . .67 WLFL1000MH/MT . . . . . . . . . . .67 WLFL1000MH/TT . . . . . . . . . . . .67 WLWPWG 2 . . . . . . . . . . . . . . . .70 WLWPWG 3 . . . . . . . . . . . . . . . .70 WMG100 . . . . . . . . . . . . . . . . .131 WMG125 . . . . . . . . . . . . . . . . .131 WMG150 . . . . . . . . . . . . . . . . .131 WMG200 . . . . . . . . . . . . . . . . .131 WEB160606 WEB160806 WEB180808 WEB240606 WEB240808 WEB241010 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 WJB242424 . . . . . . . . . . . . . . .161 WJB302412 . . . . . . . . . . . . . . .161 WJB302418 . . . . . . . . . . . . . . .161 WJB362418 . . . . . . . . . . . . . . .161 WJB362424 . . . . . . . . . . . . . . .161 WJBF040404 . . . . . . . . . . . . . .162 WLFL150HPS/MT . . . . . . . . . . .67 WLFL150HPS/TT . . . . . . . . . . . .67 WLFL175MH/MT . . . . . . . . . . . .67 WLFL175MH/TT . . . . . . . . . . . . .67 WLFL250HPS/MT . . . . . . . . . . .67 WLFL250HPS/TT . . . . . . . . . . . .67 WMG38 . . . . . . . . . . . . . . . . . .131 WMG50 . . . . . . . . . . . . . . . . . .131 WMG75 . . . . . . . . . . . . . . . . . .131 X100M . . . . . . . . . . . . . . . . . . .121 X125M . . . . . . . . . . . . . . . . . . .121 X150M . . . . . . . . . . . . . . . . . . .121 WEB241210 WEB241212 WEB241812 WEB361212 WEB361812 WEB362412 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .163 WJBF060404 WJBF060604 WJBF060606 WJBF080604 WJBF080606 WJBF080804 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLFL250MH/MT . . . . . . . . . . . .67 WLFL250MH/MT S828 . . . . . . .67 WLFL250MH/TT . . . . . . . . . . . . .67 WLFL400HPS/MT . . . . . . . . . . .67 WLFL400HPS/TT . . . . . . . . . . . .67 WLFL400MH/MT . . . . . . . . . . . .67 X200M . . . . . . . . . . . . . . . . . . .121 X50M . . . . . . . . . . . . . . . . . . . .121 X75M . . . . . . . . . . . . . . . . . . . .121 XD010 . . . . . . . . . . . . . . . . . . . .167 XD012 . . . . . . . . . . . . . . . . . . . .167 XD014 . . . . . . . . . . . . . . . . . . . .167 WEB363612 WJB040403 WJB040404 WJB060404 WJB060604 WJB060606 . . . . . . . . . . . . . . .163 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 . . . . . . . . . . . . . . .161 WJBF080806 WJBF080808 WJBF100806 WJBF100808 WJBF101006 WJBF101008 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 . . . . . . . . . . . . . .162 WLFL400MH/MT S828 . . . . . . .67 WLFL400MH/TT . . . . . . . . . . . . .67 WLFLGS 2 . . . . . . . . . . . . . . . . .70 WLFLGS 3 . . . . . . . . . . . . . . . . .70 WLFLGS 4 . . . . . . . . . . . . . . . . .70 WLFLSB 3 . . . . . . . . . . . . . . . . .70 XD3 XD4 XD5 XD6 XD7 XD8 182 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds . . . . . . . . . . . . . . . . . . . . .167 . . . . . . . . . . . . . . . . . . . . .167 . . . . . . . . . . . . . . . . . . . . .167 . . . . . . . . . . . . . . . . . . . . .167 . . . . . . . . . . . . . . . . . . . . .167 . . . . . . . . . . . . . . . . . . . . .167 Catalog Number Page Catalog Number Page Catalog Number Page Catalog Number Page XD9 . . . . . . . . . . . . . . . . . . . . .167 XJ128 . . . . . . . . . . . . . . . . . . . .168 XJ148 . . . . . . . . . . . . . . . . . . . .168 XJG104 . . . . . . . . . . . . . . . . . . .168 XJG104 EMT . . . . . . . . . . . . . .169 XJG108 . . . . . . . . . . . . . . . . . . .168 XJG14 . . . . . . . . . . . . . . . . . . . .168 XJG14 EMT . . . . . . . . . . . . . . .169 XJG18 . . . . . . . . . . . . . . . . . . . .168 XJG24 . . . . . . . . . . . . . . . . . . .168 XJG24 EMT . . . . . . . . . . . . . . .169 XJG28 . . . . . . . . . . . . . . . . . . .168 XJG34 XJG34 XJG38 XJG44 XJG44 XJG48 . . . . . . . . . . . . . . . . . . .168 EMT . . . . . . . . . . . . . . .169 . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . . . .168 EMT . . . . . . . . . . . . . . .169 . . . . . . . . . . . . . . . . . . .168 XJG54 XJG54 XJG58 XJG64 XJG64 XJG68 . . . . . . . . . . . . . . . . . . .168 EMT . . . . . . . . . . . . . . .169 . . . . . . . . . . . . . . . . . . .168 . . . . . . . . . . . . . . . . . . .168 EMT . . . . . . . . . . . . . . .169 . . . . . . . . . . . . . . . . . . .168 XJG74 . . . . . . . . . . . . . . . . . . . .168 XJG74 EMT . . . . . . . . . . . . . . .169 XJG78 . . . . . . . . . . . . . . . . . . .168 XJG84 . . . . . . . . . . . . . . . . . . .168 XJG84 EMT . . . . . . . . . . . . . . .169 XJG88 . . . . . . . . . . . . . . . . . . .168 XJG94 . . . . . . . . . . . . . . . . . . .168 XJG94 EMT . . . . . . . . . . . . . . .169 XJG98 . . . . . . . . . . . . . . . . . . .168 XJGD104 . . . . . . . . . . . . . . . . .170 XJGD34 . . . . . . . . . . . . . . . . . .170 XJGD44 . . . . . . . . . . . . . . . . . .170 XJGD54 XJGD64 XJGD74 XJGD84 XJGD94 . . . . . . . . . . . . . . . . . .170 . . . . . . . . . . . . . . . . . .170 . . . . . . . . . . . . . . . . . .170 . . . . . . . . . . . . . . . . . .170 . . . . . . . . . . . . . . . . . .170 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2007 Cooper Crouse-Hinds 183 2007 Commercial Products Catalog Distributed by: For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office or Customer Service Department: In the U.S.: In Australia: Cooper Crouse-Hinds P.O. Box 4999 Syracuse, NY 13221 Toll Free: 866-764-5454 (315) 477-5531 FAX ORDERS ONLY: 1-866-653-0640 FAX: (315) 477-5179 crouse.customerctr@crouse-hinds.com Cooper Electrical Australia 61-29-743-7000 FAX: 61-29-743-7069 sales@cooperelectrical.com.au In Canada: Cooper Crouse-Hinds Canada Toll Free: 800-265-0502 (905) 507-4187 FAX ORDERS ONLY: 1-866-653-0645 FAX: (905) 568-7048 In Asia (Singapore): Cooper Crouse-Hinds Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819 sales@cchspore.com.sg In Middle East (Dubai): CEAG Middle East LLC 971-4-324-1519 FAX: 971-4-324-1640 In Mexico: In India: Cooper Crouse-Hinds, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4020 Cooper Crouse-Hinds India 91-22-5604-5150 FAX: 91-22-2404-1811 In Latin America/Caribbean: For the latest in new products and services, visit our website at: Cooper Crouse-Hinds (954) 764-3853 FAX: (954) 764-3854 www.crouse-hinds.com In Europe (Germany): Cooper Crouse-Hinds GmbH 49-6271-806500 FAX: 49-6271-806476 4733-0107 Crouse-Hinds is a registered trademark of Cooper Industries, Inc. © 2007 Cooper Industries, Inc. back cover Printed in U.S.A. spine front cover