Steel Square Boxes

advertisement
2007 Commercial Products Catalog
Distributed by:
For more information:
If further assistance is required, please contact an authorized Cooper
Crouse-Hinds Distributor, Sales Office or Customer Service Department:
In the U.S.:
In Australia:
Cooper Crouse-Hinds
P.O. Box 4999
Syracuse, NY 13221
Toll Free: 866-764-5454
(315) 477-5531
FAX ORDERS ONLY: 1-866-653-0640
FAX: (315) 477-5179
crouse.customerctr@crouse-hinds.com
Cooper Electrical Australia
61-29-743-7000
FAX: 61-29-743-7069
sales@cooperelectrical.com.au
In Canada:
Cooper Crouse-Hinds Canada
Toll Free: 800-265-0502
(905) 507-4187
FAX ORDERS ONLY: 1-866-653-0645
FAX: (905) 568-7048
In Asia (Singapore):
Cooper Crouse-Hinds Pte. Ltd.
65-6297-4849
FAX: 65-6297-4819
sales@cchspore.com.sg
In Middle East (Dubai):
CEAG Middle East LLC
971-4-324-1519
FAX: 971-4-324-1640
In Mexico:
In India:
Cooper Crouse-Hinds, S.A. de C.V.
52-555-804-4000
FAX: 52-555-804-4020
Cooper Crouse-Hinds India
91-22-5604-5150
FAX: 91-22-2404-1811
In Latin America/Caribbean:
For the latest in new products and
services, visit our website at:
Cooper Crouse-Hinds
(954) 764-3853
FAX: (954) 764-3854
www.crouse-hinds.com
In Europe (Germany):
Cooper Crouse-Hinds GmbH
49-6271-806500
FAX: 49-6271-806476
4733-0107
Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
© 2007 Cooper Industries, Inc.
back cover
Printed in U.S.A.
spine
front cover
Commercial Products Table of Contents
STEEL
OUTLET
BOXES
NONMETALLIC CEILING
BOXES
• 4" and 411/ 16" square,
switch, masonry,
utility, outlet, ceiling
fan and gangable
boxes
• Only full line of 4" square drawn and welded boxes
• All welded 4" square boxes offer raised ground screw base for
easier installation and labor savings – eliminates ground
screw/surface interference
• Drawn boxes available with concentric knockouts, combining 1/ 2"
and 3/ 4" knockout in one location; 1/ 2" may be thumb-pushed out,
requiring no tools
• For use with wood or metal studs, cable or conduit
• Complete line of covers, partitions, extension rings and accessories
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
• Made from heavy-duty engineered
thermoplastic material or steel
• Nonmetallic boxes offer quick entry and
integral clamp features for a significant
labor savings benefit
• Ceiling boxes are available as fixture and
ceiling fan rated
• Available in a number of mounting methods
See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
PVC SWITCH BOXES AND
COVERS
•
•
•
•
Single and multigang
For use with wood or metal studs
Fire rated
Device covers and low-voltage partitions
STEEL STUD
BRACKETED BOXES
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
• Special spring steel allows for quick
and easy tool-free installation
• Mounts on either side of stud and can
be easily removed or repositioned
• Sleek, low profile mounting bracket
• Far side support bracket provides support for boxes in 21/ 4" – 4"
studs
• Far side support snaps easily onto box and is secured in place by
plaster ring
• Available in shallow and deep boxes for use with conduit,
armored/metal cable or nonmetallic sheathed cable
SPEED-MOUNT™
NONMETALLIC
SWITCHBOXES
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
• Single and multigang
• For use with wood or metal studs
• Quick entry feature on all nonmetallic
boxes offers labor savings
• Integral labor saving clamping feature on
two, three, and four gang boxes
• Offer simple, labor saving press installation of devices
• Far side support available designed for use with speed-mount
boxes
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
UNI-MOUNT™ COVERS
• Cover for 4" square boxes for mounting to
metal and wood studs
• Combines mounting bracket and device
plate
WEATHERPROOF
PRODUCTS
• Available in 1/ 2", 5/ 8" and 3/ 4" raised, as a
single- or two-device cover
• Universal design fits all 4" square boxes
• Eliminates the need for far side support
• Can be ordered preassembled to popular 4" square boxes for even
greater labor savings
•
•
•
•
Single, multigang and round outlet boxes
Covers, adapters and extensions
Vaporproof fixtures
Lampholders, photo-controls, and
accessories
See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
FIXTURE HANGERS
See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
• Ideal for commercial or light industrial
applications where HID high bay and low
bay lighting fixtures are used
• Available in two styles; one for attachment
to round and octagonal boxes, the other
for attachment to 4" square boxes
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
1
Commercial Products Table of Contents
WEATHERPROOF HID
LUMINAIRES
• Suitable for general lighting indoors and out
• Available in Wall Packs, Floodlights and Area
Lighting
• Typical applications include parking garages,
street lighting, recreational lighting, storage
areas, stairwells, corridors, lobbies and
security lighting
FITTINGS (FOR USE WITH THINWALL &
RIGID CONDUIT)
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
MYERS® HUBS
The most complete
offering of the preeminent name in hubs
• Available as Scru-tite® hub in
zinc or aluminum, 1/ 2" – 6", with
or without grounding screw on
the lock nut
• Stainless steel hubs made from
316 stainless with stainless
steel grounding screw, available
from 1/ 2" – 2"
• Through bulk-head hubs without nipples, available in zinc or
aluminum from
1/ 2" – 2"; fittings supplied with nipples from 1/ 2" – 6"
• IEC/CENELEC-approved hubs including increased safety ground
terminal and locking screw on lock nut – ideal for OEMs with
international applications
• Metric-to-NPT adapters available in zinc or stainless
• Cap-offs for knockouts available in zinc 1/ 2" – 2" or aluminum
1/ 2" – 2"; drain plugs available in 1/ 2" in aluminum and stainless steel
• Optional nickel-chrome finish available for use with zinc Scru-tite
hubs 1/ 2" – 21/ 2"
• Extensive line of steel setscrew and compression connectors
(insulated and noninsulated) and couplings from 1/ 2" – 4" for use
with thinwall (EMT) conduit
• Die-cast zinc setscrew and compression connectors (insulated and
noninsulated) and couplings from 1/ 2" – 4" for use with thinwall
(EMT) conduit
• Extensive line of steel setscrew and compression connectors
(insulated and noninsulated) and couplings from 1/ 2" – 6" for use
with IMC and rigid conduit
• Malleable three-piece couplings available from 1/ 2" – 6"
• Rainboot, the only raintight threadless fitting, available from 1/ 2" – 2"
• Malleable split conduit couplings available from 1/ 2" – 6"
• Bushed nipples, pull elbows and offset conduit nipples available in
malleable iron and die-cast zinc
See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
EMT BENDSAVER™ CONDUIT STRAPS
AND COUPLINGS
• No offset bends required when installing conduit
• Only one strap and one coupling are required per conduit run
• Patented design eliminates conduit bending and allows for
automatic alignment of EMT to box knockouts
• Conduit straps are steel with zinc plating, couplings are zinc die
cast
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
RAINTIGHT MALLEABLE
IRON CONDUIT HUBS
• Male thread type
• Tapered female thread for rigid conduit
and IMC
• Recessed o-ring gasket assures raintight
and dust tight connections
• Insulated throat provides smooth pulling surface
• Locking screw on the nut doubles as a grounding screw for added
safety
• Complete size range from 1/ 2" to 6"
• Hubs fit standard knockouts. No special tools required
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
RAINTIGHT EMT
COMPRESSION
FITTINGS
• All steel construction with zinc
electroplate finish provides for durable
corrosion resistance
• Flat surface on gland nut provides smooth flat surface for easy
wrenching
• Integral ‘‘tri-level’’ sealing design includes steel compression ring,
metal washer and nylon gasket for secure, reliable installation
• Interior shoulder conduit stop provides positive seating of conduit
inside the body
• Gasket on male threads of box connector seals installation for
raintight connection between the box and the connector
• No disassembly required
• Available in insulated and non-insulated versions, trade sizes
1/ 2" – 4"
See page. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
2
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Commercial Products Table of Contents
SPACE-SAVER EMT SETSCREW & COMPRESSION
CONNECTORS &
COUPLINGS
GROUNDING BUSHINGS
• Male threads on locknut allow for more
room inside the box
• Smooth pulling surface won’t strip cable—
no bushing or insulated throat required
• Angled teeth on locknut bite into enclosure, preventing loosening
from vibration
• Knurled wrenching surface for easy tightening
• Zinc electroplated for corrosion resistance
• Concrete tight when taped
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
FORM 5™ MALLEABLE
IRON CONDUIT OUTLET
BODIES
• Available from 1/ 2" – 4" in the most
popular conduit body shapes (C, LB,
LL, LR, T, TB and X)
• Domed sheet steel covers with stainless
steel cover screws provide additional
internal capacity
• Cast iron covers available in 1/ 2" – 4"
• Neoprene gaskets have perforated centers that are easily removed,
if required
• Completely interchangeable with Appleton® Form 35® and
OZ/Gedney® malleable iron bodies and covers
• UL List NEMA 4 Rated integral asket covers
• All configurations available as SnapPack™
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
SERIES 5® DIE-CAST
ALUMINUM CONDUIT
BODIES, COVERS &
GASKETS
• Available for use with rigid or EMT conduit
(with setscrew)
• Bodies available from 1/ 2" – 4" in the most popular conduit body
shapes (C, LB, LL, LR, and T)
• Available with fiber or neoprene gasket and aluminum cover as
separate SKUs or prepackaged together and individually bar-coded
as "SnapPack™"
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
• Available in 1/ 2" – 6" in threaded or
setscrew style
• Available with aluminum or copper lug
which can be rotated 360°; open design
for easy lay-in of wiring
• Available in commercial-grade version rated for 105°C and hightemperature version rated for 150°C
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
LIQUIDTIGHT FITTINGS
Extensive product offering of Liquidtight
fittings including:
• Liquidator™ series available in malleable
iron, aluminum, insulated or noninsulated,
with or without grounding lug (copper or
aluminum), and in straight, 45° or 90°
configurations
• LiQuik™ series, no disassembly required available in straight
3/ 8" – 2" trade sizes, insulated or non-insulated
• Low Profile series available for confined space applications, in
straight, 45° or 90° configurations, 3/ 8" – 2" trade sizes
• Zinc Die Cast series available in straight or 90° configurations,
3/ 8" – 4" trade sizes, insulated or non-insulated
• Nonmetallic Liquidtight fittings for use with Type B liquidtight conduit
available in straight or 90° configurations, 1/ 2" – 1" trade sizes
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
CORD GRIPS IN METALLIC
AND NONMETALLIC
• Use with portable cords including S, SO,
STO, ST, SJT, SJTO and SVO
• Neoprene bushing
• Metallic cord grips available in straight in
1/ 2" – 11/ 2" and 45° and 90°in 1/ 2" – 1"
trade sizes
• Nonmetallic cord grips available in straight
3/ 8"– 1" trade sizes
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136
ACB SERIES CONNECTORS
(Armored Cable, Metal Clad and Flexible Metallic
Conduit fittings)
• Dual gripping saddle design on connector safely secures cable or
conduit in place and prevents loosening from vibration
• Insulated throat provides a smooth pulling surface that won’t strip
cable
• Angled teeth on locknut bit into enclosure, preventing loosening
from vibrations
• Available in straight 3/ 8" – 4", 45° 3/ 8" – 3/ 4" and 90° 3/ 8" – 1"
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
3
Commercial Products Table of Contents
ACC SERIES COUPLINGS
(Armored Cable, Metal Clad and Flexible Metallic
Conduit fittings)
CONDUIT CLAMPS &
STRAPS
• Dual gripping saddle design on the coupling safely secures cable or
conduit in place and prevents loosening from vibration
• Steel compression ring & nut provide a strong, secure termination
point for EMT conduit
• Available in both compression and set-screw (ACCSS) versions
3/ 8" – 3/ 4"
• Wide variety of conduit clamps and straps
for EMT, IMC and rigid conduit
• Clamps include: right angle, parallel,
edge, U-bolt and J series conduit beam
clamps
• Straps include: two hole, snap on, nailing, and malleable, plus cable
and conduit hangers
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
SSACB SERIES CONNECTORS
ACCESSORIES
(Armored Cable, Metal Clad and Flexible Metallic
Conduit fittings)
• Extensive offering including: locknuts, plugs,
pennies, reducing washers and conduit
reducers
• Male threads on locknut allow for more room inside the box
• Smooth pulling surface eliminates the need for insulated throat
fittings and/or conduit bushings
• Dual gripping saddle design on the fitting safely secures cable or
conduit in place and prevents loosening from vibration
• Available 3/ 8" – 1" trade sizes
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
QUICK-LOK™ SQUEEZEAND-CLAMP TYPE
CONNECTORS
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
W-SERIES CAST-IRON
WEATHERPROOF
JUNCTION BOXES &
ACCESSORIES
• Extensive line of over 196 boxes in five
different styles (WAB, WCB, WJB, WJBF
and WEB)
• Many of the most popular sizes are
available to ship within 24 hours when you
request Lightning Service™ delivery
• XJG internally grounded and XD
weathertight expansion and deflection
fittings available
• One-piece steel construction for easy
snap-in installation of MC and AC cable.
Also suitable for use with 3/ 8" and 1/ 2" FMC
connectors. Available in 1/ 2" and 3/ 4" sizes
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
See page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
ZINC DIE CAST FITTINGS
• Expanded line of connectors and
couplings for EMT, AC & FMC conduit
• Zinc EMT fittings available in set-screw
and compression type fittings
• Zinc AC & FMC fittings available in
squeeze type, clamp type and screw-in
type, straight or 90 degree angle
• Available with insulators
• Zinc material is naturally corrosion
resistant
See pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92-145
4
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
ALPHABETICAL INDEX
PRODUCT
CATALOG
PAGE NUMBERS
Adapters
Knockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Angle Connectors
Armored Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145
Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Flexible Metallic Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145
Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Thinwall (EMT) Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 149
Anti-Short Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141, 147
Armored Cable Fittings
ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
ACC Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
ACCSS Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Armored Cable Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Quik-Lok . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Space-Saver ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
BX Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Beam Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109, 141
Benders (EMT)
Benders (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100
EMT Bendsaver™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95
Bushings
Anti-Short . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 147
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Insulated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Insulating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
Non-insulated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Pennies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
Cable Selection Chart153
Clampbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95, 109
Clamps
AC/FMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109, 141
Edge Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Parallel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111, 141
Right Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111, 141
Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 141
Thinwall (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 149
Closure Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62, 75
Conduit Outlet Bodies
Bodies, Covers & Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Cast Iron Form 5™ Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109
Form 5™ Integral Gasket Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Form 5™ Malleable Iron Bodies
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83, 106
Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
Connectors
Armored Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
BX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Cord Metallic & Non-Metallic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136
Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149
EMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99
EMT Raintight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
EMT Space-Saver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
EMT Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100
Flexible Metal Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Greenfield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
Nonmetallic Sheathed Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149
Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100, 108
RAINBOOT™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83, 91, 141
Romex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Service Entrance Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Thinwall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99, 109, 149
Cord Grips Metallic & Non-Metallic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136
Couplings
Combination:
EMT–Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100, 109, 139
EMT–Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 99
US: 1-866-764-5454
CAN: 1-800-265-0502
PRODUCT
CATALOG
PAGE NUMBERS
Liquidtight–Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126, 131
Rigid–Flex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100
Compression:
EMT Raintight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89
EMT Space-Saver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
EMT Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100
EMT(Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99
Expansion/Deflection
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167
RAINBOOT™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99
Rigid/IMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 97
Duplex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149
Elbows
Entrance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Pull . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Entrance Caps
EMT (Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Entrance Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Far Side Support for Speed-Mount boxes . . . . . . . . . . . . . . . . . . . . . . . . . .56
Flexible Metallic Conduit Fittings
ACCSS Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Duplex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Greenfield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145, 149
Quik-Lok . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Flexible Metallic Conduit Fittings
ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
ACC Combination Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Flexible Metallic Conduit Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Space-Saver ACB Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 141, 145
Floodlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Form 5™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Gaskets
Conduit Body . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121
Sealing Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Grounding
Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Liquidtight Conduit Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125, 133
Locknuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Hangers, Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111, 141
Hangers, Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74, 88
Heads
Entrance, EMT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Entrance, Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Hubs
Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
Iron Space Saver Conduit Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . .83, 87, 114
Raintight Malleable Iron Conduit Hubs . . . . . . . . . . . . . . . . . . . . . .83, 87, 114
Insert Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113
Insulated Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Insulator Supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111, 141
Junction Boxes
Cast, Weatherproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Drill and Tapping Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Knockout, Reducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Knockout, Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Lampholder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57, 66
Lazy-Lug®
For Liquidtight Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128
Grounding Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .102
Liquidtight Conduit Connectors
LiQuik™ Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Liquidator Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
Liquidtight Conduit Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125, 133
Low Profile Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133
Non-metallic Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
Zinc Die Cast Liquidtight Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Liquidtight Replacement Ferrules . . . . . . . . . . . . . . . . . . . . . . . . . . .131, 133
Locknuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Locknuts, Sealing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Copyright© 2007 Cooper Crouse-Hinds
5
ALPHABETICAL INDEX
PRODUCT
CATALOG
PAGE NUMBERS
Luminaires
HID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74, 88
Incandescent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 76
Myers® Hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Nailing Straps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95, 109, 149
Nipples
Bushed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Threaded Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
No-Thread Fittings
EMT (Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99
Rigid Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 99
Non-insulated Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100
Offset Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100, 108
Offset Nipples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42, 50, 52
Pennies, Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Perforated Strap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
Plastic Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Plastic Bushings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Plugs, Insert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Pre-Fab 4" Square Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Pull Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Push Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Quick Lok® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141, 145, 149
RAINBOOT™ Set Screw Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Raintight Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reducing Washers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Romex Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Sealing Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Sealing Locknuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Series 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117
Service Entrance
Cable Clamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Cable Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Caps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Spacers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109, 149
Set Screw:
EMT Space-Saver Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
EMT Space-Saver Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91
EMT Zinc Die Cast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100
EMT(Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89, 99
Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91, 99
Split Conduit Couplings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
Three Piece Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
Two Piece (EMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92, 100
Speed-Mount™ Nonmetallic Switchboxes . . . . . . . . . . . . . . . . . . . . . . . . 56
Strain Relief Cord Connectors
Strain Relief Cord Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136
Wire Mesh Grip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Straps
EMT (Thinwall) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 149
Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Nailing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109, 149
Perforated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149
Rigid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95, 109
Switch & Outlet Boxes—Nonmetallic
Covers:
4" Square & Round PVC Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Nonmetallic – Ceiling Boxes:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
31/2" Diameter
4" Diameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 57
PVC – Switch Boxes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4" Square . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Multi-Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Multi-Gang Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Single Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Switch & Outlet Boxes—Steel
Bar Hangers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Box & Bar Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 57
6
US: 1-866-764-5454
CAN: 1-800-265-0502
PRODUCT
CATALOG
PAGE NUMBERS
Bracket & Clamp Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Ceiling Fan Boxes & Supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28, 57
Ceiling Pans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Concrete Boxes & Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Covers:
3-1/4" Round Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4" Octagon Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
4" Square Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
4" Square Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
411/16" Square Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Gang Box Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Gang Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Masonry Partitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Plenum Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27, 40, 45
Uni-Mount™ Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Utility Box Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Hung Ceiling Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Outlet Boxes:
31/4" Octagon & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4" Octagon & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4" Square & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
411/16" Square & Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Gang Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Masonry Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Plenum Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23, 30, 42
Pre-Fab 4" Square Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Steel Specialty Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Steel Stud Bracketed Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Utility Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Switch Boxes:
1" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
11/2" Deep
2" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1
2 /2" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
21/4" Deep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
23/4" Deep
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
31/2" Deep
EC–extra capacity boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Instant–on boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Switch Box
Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Utility Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Switch Box Accessories
Extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Grounding Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Hold It Switch Box Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Stud Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Swiv-L-Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74, 88
U-Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
Uni-Mount™ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Unions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
Wall Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Watertight Connectors
Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .136
Weatherproof
Covers:
1 & 2 Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
1 & 2 Gang GFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
1 & 2 Gang Toggle Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Aluminum Blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Extension Adaptor Rings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Round & Rectangular . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Indoor/Outdoor Decorative:
Lampholders & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
Wall Bracket Fixture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Outlet Boxes:
1 & 2 Gang extensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
2 & 3 Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Photoelectric Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Round . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Single Gang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Vapor Proof Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 76
Vapor Proof Fixtures & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .72, 76
Wire Mesh Grips (Liquidtight) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Copyright© 2007 Cooper Crouse-Hinds
O
U
T
L
E
T
B
O
X
E
S
OUTLET BOXES
MYERS® HUBS
Outlet Boxes
EMT FITTINGS
RIGID / IMC FITTINGS
GROUND BUSHINGS
OUTLET BODIES
LIQUIDTIGHT
FITTINGS
CORD AND CABLE
CONNECTORS
ARMORED CABLE
AND FMC FITTINGS
W-SERIES
JUNCTION BOXES
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
7
Technical Data – Switch & Outlet Boxes
Article 314 of the National Electrical Code®
(NEC®) covers the installation and use of
boxes. The article includes table references
that guide the electrician in the selection of
the proper size box necessary to safely
accommodate electrical service
requirements. The box capacity table is
reproduced in part from NEC as a quick
reference and guide. The NEC should be
consulted for complete details.
Cooper Crouse-Hinds products are
produced in accordance with the
requirements of UL-514-A, UL-514-B, UL514-C and are classified for fire resistance
according to the standard, Fire Tests of
Building Construction and Materials,
ANSI/UL 263, ASTM E 119 and NFPA 251.
This listing is based on products when
used in a fire rated (2 HR) wall or ceiling.
Cooper Crouse-Hinds steel boxes are listed
with U.L. File #E23156 and Cooper CrouseHinds nonmetallic boxes are listed with U.L.
File #E102328 and U.L. (2 HR. fire rated)
File #R9933.
Cooper Crouse-Hinds switch and outlet
boxes comply with the requirements of
NEMA standard OS-1, NFPA 70-370 and
Federal Spec. #W-J-800E.
Under File #E23156, Cooper Crouse-Hinds
concentric and "Moon" KO style boxes, the
following is stated "Suitable for bonding
without any additional bonding means
around concentric (or Eccentric) knockouts
where used in circuits above or below
250V."
Cooper Crouse-Hinds NAED/DCI/UPC
number is 786189-10 plus the 3-digit
product number. On the outlet box 4-digit
product number, the NAED/DCI/UPC
number is 786189-0 plus the 4-digit product
number and for the 5-digit product number,
the NAED/DCI/UPC number is 786189 plus
the 5-digit number.
Table 314.16 (A) Metal Boxes
Min.
Maximum Number of Conductors
Cu.
In.
Cap. No. 18 No. 16 No. 14 No. 12 No. 10 No. 8 No. 6
Box Dimension, Inches
Trade Size or Type
4 × 11/ 4 Round or Octagonal
4 × 11/ 2 Round or Octagonal
4 × 21/ 8 Round or Octagonal
4 × 11/ 4 Square
4 × 11/ 2 Square
4 × 21/ 8 Square
411/ 16 × 11/ 4 Square
411/ 16 × 21/ 2 Square
411/ 16 × 21/ 8 Square
3 × 2 × 11/ 2 Device
3 × 2 × 2 Device
3 × 2 × 21/ 4 Device
3 × 2 × 21/ 2 Device
3 × 2 × 23/ 4 Device
3 × 2 × 31/ 2 Device
4 × 21/ 8 × 11/ 2 Device
4 × 21/ 8 × 17/ 8 Device
4 × 21/ 8 × 21/ 8 Device
33/ 4 × 2 × 21/ 2 Masonry Box/Gang
33/ 4 × 2 × 31/ 2 Masonry Box/Gang
FS-Minimum Internal Depth
13/ 4 Single Cover Gang
FD-Minimum Internal Depth
23/ 8 Single Cover Gang
FS-Minimum Internal Depth
13/ 4 Single Cover Gang
FD-Minimum Internal Depth
23/ 8 Multiple Cover Gang
12.5
15.5
21.5
18.0
21.0
30.3
25.5
29.5
42.0
7.5
10.0
10.5
12.5
14.0
18.0
10.3
13.0
14.5
14.0
21.0
8
10
14
12
14
20
17
19
28
5
6
7
8
9
12
6
8
9
9
14
7
8
12
10
12
17
14
16
24
4
5
6
7
8
10
5
7
8
8
12
6
7
10
9
10
15
12
14
21
3
5
5
6
7
9
5
6
7
7
10
5
6
9
8
9
13
11
13
18
3
4
4
5
6
8
4
5
6
6
9
5
6
8
7
8
12
10
11
16
3
4
4
5
5
7
4
5
5
5
8
4
5
7
6
7
10
8
9
14
2
3
3
4
4
6
3
4
4
4
7
2
3
4
3
4
6
5
5
8
1
2
2
2
2
3
2
2
2
2
4
13.5
9
7
6
6
5
4
2
18.0
12
10
9
8
7
6
3
18.0
12
10
9
8
7
6
3
24.0
16
13
12
10
9
8
4
Table 314.16 (B) Volume
Required per Conductor
Size of
Conductor
Free Space
Within Box for
Each Conductor
No. 18
No. 16
No. 14
No. 12
No. 10
No. 8
No. 6
1.5 cubic inches
1.75 cubic inches
2 cubic inches
2.25 cubic inches
2.5 cubic inches
3 cubic inches
5 cubic inches
For SI units: one cubic inch = 16.4 cm3.
Reprinted with permission from NFPA 70-2005,
the National Electrical Code®, Copyright® 2005
National Fire Protection Association, Quincy MA
02269. This reprinted material is not the complete
and official position of the National Fire Protection
Asociation, on the referenced subject which is
represented only by the standard in its entirety.
National Electrical Code® and NEC® are registered
trademarks of the National Fire Protection
Association, Inc., Quincy, MA 02269.
Wall thickness on all Steel boxes is 0.0625"
8
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Technical Data – Switch & Outlet Boxes
COOPER CROUSE-HINDS SWITCH BOX DETAILS
1/ 2"
Conduit KO
3/ 4"
Conduit KO
1" Conduit KO
Concentric 1/2" and 3/4"
KO
Eccentric 1/2" and 3/4" KO
Cable Pry-outs always in pairs.
Knockouts and Pry-outs
Cooper Crouse-Hinds conduit KOs have
standard trade size dimensions. KOs are
uniform and true for attachment of cable or
conduit connectors. Pry-outs for cable
entrance are slotted – a twist with
screwdriver removes them. KOs and Pryouts are precision stamped to permit easy
removal, but remain sufficiently strong and
sturdy when not removed.
Cooper Crouse-Hinds 4" sq. drawn boxes
feature a 1/ 2" and 3/ 4" "inverted" concentric
KO – easily removed. Our 4" sq. welded
feature our 1/ 2" eccentric KO which also
features easy removability of both the 1/ 2"
and 3/ 4" KOs.
Notes:
These KOs are suitable for bonding without bonding
jumpers around concentric (or eccentric) knockouts where
used in circuits above or below 250V.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
9
Mounting Information
Steel Boxes
BRACKETS USED ON COOPER CROUSE–HINDS BOXES
"F" BRACKET
"D" BRACKET
"S" BRACKET
"C" BRACKET
Mounts on face of stud. See
catalog number for set back. For
wood studs.
Side mount bracket with set up
hook & guide tabs for automatic
positioning. Standard bracket set
back is 5/ 8". For wood and metal
studs.
Side mount brackets with set up
hook for wood or metal studs.
Standard bracket set back is 5/ 8".
Ceiling box bracket for wood
studs.
"VS" BRACKET
"VMS" BRACKET
"VP" BRACKET
"SSB" BRACKET
Plain flat mounted bracket for use
on wood or metal studs. No set
back.
Side bracket for use with wood or
metal studs. Provides set up tabs
to position on face of stud.
Side bracket with set up hooks for
wood studs.
Positions box on either side of a
steel stud.
CLAMPS USED ON COOPER CROUSE-HINDS BOXES
Cat. # TP900
MC-BX
FOR ARMORED & METAL CLAD
(MCI) CABLE
NM-1
NM-2
FOR NONMETALLIC CABLE
NM-4
MOUNTING EARS
Cat. # TP901
Cat. # TP902
ONE SCREW EAR
TWO SCREW EAR
Mounting ears are available on many of our switch boxes. They are set forward in
and one-screw ears on deep boxes.
10
US: 1-866-764-5454
1/ 16"
CAN: 1-800-265-0502
the "old way" position. Two-screw ears are generally used on shallow boxes
Copyright© 2007 Cooper Crouse-Hinds
Steel Switch Boxes
1" DEEP SWITCH BOXES – NON-GANGABLE – 6.5 CUBIC INCH CAPACITY
115/16" WIDE × 33/4" LONG
Steel Boxes
TP101
TP103
Cat. #
Bracket
Plastic Clamp
TP101
TP103
"S"
"S"
No
Yes
KNOCKOUTS
Conduit
Cable
1 – 1/ 2"
1 – 1/ 2"
2
2
Std. Unit Pkg.
Wt. Lbs. Per 100
25
25
38
39
11/2" DEEP SWITCH BOXES – NON-GANGABLE – 7.5 CUBIC INCH CAPACITY
2" WIDE × 3" LONG
TP100
Cat. #
Bracket
TP104
Ears
TP106
KNOCKOUTS
Each Side
Each End
TP114
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
50
50
43
50
FOR ARMOURED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP106
—
Yes
2 – Cable
—
1 – 1/ 2"
50
44
FOR CONDUIT – NO CLAMPS, FLUSH DEVICE
TP114
—
Yes
1 – 1/ 2"
1 – 1/ 2"
50
39
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
TP100
—
Yes
2 – Cable
TP104
—
2 – Cable
"S", set 1/ 2"
US: 1-866-764-5454
—
—
—
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
11
Steel Switch Boxes
2" DEEP SWITCH BOXES – GANGABLE – 10.0 CUBIC INCH CAPACITY
Steel Boxes
2" WIDE × 3" LONG,
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
TP116
TP118
Cat. #
Bracket
Ears
Each End
TP116
TP118
—
"S", Set 1/ 2"
Yes
—
2 – Cable
2 – Cable
KNOCKOUTS
Each Side
—
—
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
50
50
53
60
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP120
Cat. #
TP120
TP123
TP124
Bracket
—
"F", Set 1/ 2"
"S", Set 1/ 2"
TP123
Ears
Yes
—
—
Each End
KNOCKOUTS
Each Side
2 – Cable
2 – Cable
2 – Cable
TP124
Bottom
1/ 2"
—
—
—
1–
1 – 1/ 2"
1 – 1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
54
63
61
FOR CONDUIT – NO CLAMPS, FLUSH DEVICE
TP126
TP130
Cat. #
Bracket
Ears
Each End
TP126
TP130
TP132
TP131
—
—
"S", Set 1/ 2"
Hold-Tite
—
Yes
—
Yes
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"–T
12
US: 1-866-764-5454
TP132
KNOCKOUTS
Each Side
2 – 1/ 2"
2 – 1/ 2"
2 – 1/ 2", 1 Side
—
CAN: 1-800-265-0502
Bottom
1
1
1
1
–
–
–
–
TP131
Hold-Tite
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
47
48
58
52
1/ 2"
1/ 2"
1/ 2"
1/ 2"
Copyright© 2007 Cooper Crouse-Hinds
Steel Switch Boxes
21/4" DEEP SWITCH BOXES – GANGABLE – BEVELED CORNERS
10.5 CUBIC INCH CAPACITY
2" WIDE × 3" LONG,
CLAMP SCREWS THROUGH BEVELED CORNERS
Steel Boxes
TP134
Cat. #
TP134
TP137
TP138
Ears
—
Yes
Yes
TP137
Hold-Tite
Bumps
Yes
—
—
Each End
2 – Cable
2 – Cable
2 – Cable
US: 1-866-764-5454
KNOCKOUTS
Each Side
—
—
—
CAN: 1-800-265-0502
TP138
Bottom
1/ 2"
1–
1 – 1/ 2"
1 – 1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
51
57
55
Copyright© 2007 Cooper Crouse-Hinds
13
Steel Switch Boxes
21/2" DEEP SWITCH BOXES – GANGABLE – 12.5 CUBIC INCH CAPACITY
Steel Boxes
2" WIDE × 3" LONG
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
TP158
TP162
TP163
TP170
TP161
TP172
TP164
TP168
TP174
TP171
KNOCKOUTS
Cat. #
TP115
TP158
TP161
TP162
TP163
TP164
TP168
TP170
TP172
TP174
TP171
14
Bracket
—
—
Snap-In
—
Hold-Tite
"F", Set 1/ 2"
"F", Set 1/ 4"
"S", Set 5/ 8"
"D", Set 5/ 8"
"D", Set 5/ 8"
"VP", Set 1/ 2"
Ears
—
Yes
Yes
Yes
Yes
—
—
—
—
—
—
Ground Pigtail
—
Yes
—
—
—
—
—
—
—
Yes
—
US: 1-866-764-5454
Leveling
Bumps
Yes
—
—
—
—
—
—
—
—
—
—
Each End
2 – Cable, 1 –
2 – Cable
2 – Cable
2 – Cable
2 – Cable
2 – Cable, 1 –
2 – Cable, 1 –
2 – Cable, 1 –
2 – Cable, 1 –
2 – Cable, 1 –
2 – Cable, 1 –
CAN: 1-800-265-0502
Each Side
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
—
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
—
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
Bottom
1/ 2"
1–
1 – 1/ 2"
—
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
Copyright© 2007 Cooper Crouse-Hinds
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
50
50
50
50
50
50
50
59
63
73
62
65
71
71
69
70
71
73
Steel Switch Boxes
21/2" DEEP SWITCH BOXES – GANGABLE – 12.5 CUBIC INCH CAPACITY
2" WIDE × 3" LONG FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP178
TP179
Hold-Tite
TP184
TP185
KNOCKOUTS
Each Side
Cat. #
Bracket
Ears
Each End
TP177
TP178
TP179
TP180
TP184
TP185
Snap-In
—
Hold-Tite
"F", Set 1/ 2"
"S", Set 5/ 8"
"VP", Set 1/ 2"
Yes
Yes
Yes
—
—
—
2 – Cable
2 – Cable
2 – Cable
2 – Cable, 1 – 1/ 2"
2 – Cable, 1 – 1/ 2"
2 – Cable, 1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
—
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
Bottom
1
1
1
1
1
Steel Boxes
TP177
TP180
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
50
50
74
63
66
72
70
74
—
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
GANG SWITCH BOXES WITH VP BRACKET, SET BACK 1/2"
21/2" DEEP – 33/4" HIGH – 1/2" AND 3/4" CONCENTRIC KOs
TP632
TP633
Cat. #
Gang
Width
Each End
TP632
TP633
3
4
59/ 16"
73/ 8"
2
2
KNOCKOUTS
Each Side
US: 1-866-764-5454
3
4
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
6
8
5
5
143
179
46.5
62.0
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
15
Steel Switch Boxes
21/2" DEEP "EC" BOXES – GANGABLE – CUBIC INCH CAPACITY (SEE BELOW)
Steel Boxes
2" WIDE × 3" LONG
CLAMPS IN EACH END
TP188
TP190
TP196
NOW… The Cubic Capacity of any of our new work 21/ 2" Deep Switch Boxes can be increased to 18 cubic inches simply by adding our "EC" Extender to the sides
of the box. This provides 5.5 extra cubic inches of space necessary to conform to revisions in the National Electrical Code. "EC" boxes are stocked factory
assembled in popular styles, however the "EC" Extender can be ordered separately for "Instant-On" assembly on the job with Cooper Crouse-Hinds Switch Boxes.
Cat. #
Bracket
Each End
TP188
—
—
KNOCKOUTS
Each Side
FOR NONMETALLIC CABLE
TP190
"D", Set 5/ 8"
2 – Cable, 1 – 1/ 2"
TP196
"S", Set 5/ 8"
2 – Cable, 1 – 1/ 2"
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
—
—
50
32
5.5
—
—
1 – 1/ 2"
1 – 1/ 2"
25
25
89
89
18.0
18.0
21/2" DEEP SWITCH BOXES – GANGABLE – 12.5 CUBIC INCH CAPACITY
2" WIDE × 3" LONG
FOR CONDUIT – NO CLAMPS
Cat. #
TP214
TP216
TP217
TP218
TP220
TP222
TP224
16
TP214
TP216
TP217
TP220
TP222
TP224
Bracket
—
Snap-In
—
—
"F", Set 1/ 2"
"S", Set 5/ 8"
Hold-Tite
Ears
—
Yes
Yes
Yes
—
—
Yes
Leveling Bumps
Yes
—
—
—
—
—
—
US: 1-866-764-5454
Each End
1
1
1
1
1
1
1
–
–
–
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
CAN: 1-800-265-0502
KNOCKOUTS
Each Side
—
1 – 1/ 2"
—
1 – 1/ 2"
1 – 1/ 2", 1 Side
1 – 1/ 2", 1 Side
—
TP218
Bottom
1/ 2"
1–
—
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
Copyright© 2007 Cooper Crouse-Hinds
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
50
50
50
55
69
64
58
66
65
61
Steel Switch Boxes
21/2" DEEP SWITCH BOXES – "INSTANT ON" – 12.5 CUBIC INCH CAPACITY
2" WIDE × 3" LONG
WITH BUMPS – CLAMPS IN EACH END (BUMPS LEVEL THE BOX AGAINST THE SIDE OF STUD, TOP TO
BOTTOM, FRONT TO BACK)
Steel Boxes
TP206
TP210
Cat. #
Clamps
Nails
TP206
TP210
TP213
Nonmetallic
Nonmetallic
Armored Cable
—
Angle
Angle
TP213
KNOCKOUTS
Each End
Each Side
2 – Cable, 1 – 1/ 2"
2 – Cable, 1 – 1/ 2"
2 – Cable, 1 – 1/ 2"
—
—
—
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
50
50
50
61
66
66
23/4" DEEP SWITCH BOXES – GANGABLE – 14.0 CUBIC INCH CAPACITY
2" WIDE × 3" LONG
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
TP660
TP662
Cat. #
Bracket
Ears
Each End
TP660
TP662
TP664
—
—
"S", Set 5/ 8"
—
Yes
—
2 – Cable
2 – Cable
2 – Cable
KNOCKOUTS
Each Side
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
TP664
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
50
50
50
62
67
70
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP668
Cat. #
TP668
TP670
Bracket
—
"S", Set 5/ 8"
TP670
Ears
Yes
—
Each End
2 – Cable
2 – Cable
US: 1-866-764-5454
KNOCKOUTS
Each Side
1/ 2"
1–
1 – 1/ 2"
CAN: 1-800-265-0502
Bottom
1/ 2"
1–
1 – 1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
68
71
Copyright© 2007 Cooper Crouse-Hinds
17
Steel Switch Boxes
23/4" DEEP SWITCH BOXES – GANGABLE – 14.0 CUBIC INCH CAPACITY
Steel Boxes
2" WIDE × 3" LONG
FOR CONDUIT – NO CLAMPS
TP672
TP674
(TP676 – 1 screw ear)
(TP678 – 2 screw ear)
Cat. #
Bracket
Ears
TP672
TP674
TP676
TP678
TP680
TP677
—
—
—
—
"S", Set 5/ 8"
"S", Set 5/ 8"
—
—
Yes
Yes
—
—
Each End
1
1
1
1
1
1
–
–
–
–
–
–
KNOCKOUTS
Each Side
1/ 2"
1 – 1/ 2"
1 – 3/ 4"
1 – 1/ 2"
1 – 3/ 4"
1 – 1/ 2", 1 Side
1 – 3/ 4", 1 Side
3/ 4"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
TP680
TP677
Bottom
1
1
1
1
1
1
–
–
–
–
–
–
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
50
50
59
59
61
61
70
70
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
21/2" DEEP SWITCH BOX – GANGABLE – 16.0 CUBIC INCH CAPACITY
2" WIDE × 33/4" LONG
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
TP226
Cat. #
Clamps
Bracket
Each End
TP226
Nonmetallic
External Nail
1 – 1/ 2"
18
US: 1-866-764-5454
KNOCKOUTS
Each Side
2 – 1/ 2"
CAN: 1-800-265-0502
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
50
35
Copyright© 2007 Cooper Crouse-Hinds
Steel Switch Boxes
31/2" DEEP SWITCH BOXES – GANGABLE – 18.0 CUBIC INCH CAPACITY
2" WIDE × 3" LONG
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
Steel Boxes
TP236
TP238
TP239
TP242
TP243
Cat. #
Bracket
Ground Pigtail
Ears
TP236
TP238
TP239
TP240
TP242
TP243
—
—
—
"F", Set 1/ 2"
"S", Set 7/ 8"
"S", Set 7/ 8"
—
—
Yes
—
—
Yes
—
Yes
Yes
—
—
—
US: 1-866-764-5454
Each End
2
2
2
2
2
2
–
–
–
–
–
–
Cable,
Cable,
Cable,
Cable,
Cable,
Cable,
1
1
1
1
1
1
–
–
–
–
–
–
CAN: 1-800-265-0502
KNOCKOUTS
Each Side
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
2
2
2
2
2
2
–
–
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
TP240
Bottom
1
1
1
1
1
1
–
–
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
Copyright© 2007 Cooper Crouse-Hinds
Std. Unit Pkg.
Wt. Lbs. Per 100
25
25
25
25
25
25
78
80
81
88
87
88
19
Steel Switch Boxes
31/2" DEEP SWITCH BOXES – GANGABLE – 18.0 CUBIC INCH CAPACITY
Steel Boxes
2" WIDE × 3" LONG
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP244
TP249
TP246
KNOCKOUTS
Each Side
Cat. #
Bracket
Ground Pigtail
Ears
Each End
TP244
TP249
TP246
—
—
"S", Set 7/ 8"
—
Yes
—
Yes
Yes
—
2 – Cable, 1 – 1/ 2"
2 – Cable, 1 – 1/ 2"
2 – Cable, 1 – 1/ 2"
2 – 1/ 2"
2 – 1/ 2"
2 – 1/ 2"
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
25
25
25
81
82
88
FOR CONDUIT – NO CLAMPS
TP248
TP250
TP252
Cat. #
Bracket
Ears
TP248
TP250
TP252
TP254
—
—
—
—
—
—
Yes
Yes
20
Each End
2
2
2
2
1/ 2"
–
– 3/ 4"
– 1/ 2"
– 3/ 4"
US: 1-866-764-5454
KNOCKOUTS
Each Side
2
2
2
2
1/ 2"
–
– 3/ 4"
– 1/ 2"
– 3/ 4"
CAN: 1-800-265-0502
TP254
Bottom
1
1
1
1
1/ 2"
–
– 1/ 2"
– 1/ 2"
– 1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
25
25
25
25
74
74
76
76
Copyright© 2007 Cooper Crouse-Hinds
Switch Box Accessories
GROUNDING DEVICES
GROUNDING SCREW AND PIGTAIL
TP700 or TP702
TP703 or TP707
TP701 or TP705
Description
TP700
TP701
TP702*
TP703
TP705
TP707
TP704
Grounding Screw with 6" Bare No. 14 Copper Wire
Grounding Screw with Insulated No. 12 Stranded Wire – 8" overall
Grounding Screw with 6" Bare No. 12 Copper Wire
Grounding Screw with 6" Insulated No. 12 Copper Wire
Grounding Screw with Insulated No. 14 Stranded Wire – 8" overall
Grounding Screw with 6" Insulated No. 14 Copper Wire
#10-32 x 3/ 8" Grounding Screw
Std. Pkg.
Unit Pkg.
Wt. Lbs. Per 100
1000
1000
1000
1000
1000
1000
1000
50
50
50
50
50
50
100
1
2
2
2
1
1
.5
Steel Boxes
Cat. #
TP704
*TP702 is standard wire installed in Cooper Crouse-Hinds boxes
GROUNDING CLIP
TP706
Cat. #
Description
TP706
For Grounding Switch & Outlet Boxes Using Nonmetallic Sheathed Cables No. 14 &
No. 12, with Grounding Wire
Std. Pkg.
Unit Pkg.
Wt. Lbs. Per 100
1000
100
.5
OLD WORK CLIP
TP651
Cat. #
Description
Std. Pkg.
Unit Pkg.
Wt. Lbs. Per 100
TP651
Clips lock old-work steel switch boxes tightly to wall. Two required per box.
250 sets
25 sets
4
REPLACEMENT PARTS
TP900
TP901
Cat. #
Description
TP900
TP901
TP902
MC-BX Clamp with Screws
One Screw Mounting Ear with Screws
Two Screw Mounting Ear with Screws
US: 1-866-764-5454
CAN: 1-800-265-0502
TP902
Unit Pkg.
Wt. Lbs. Per 100
200
200
200
17.3
3.2
2.7
Copyright© 2007 Cooper Crouse-Hinds
21
Switch Box Accessories
Steel Boxes
HOLD-IT SWITCH BOX SUPPORTS
FIG. 1
FIG. 2
FIG. 3
Cat. #
Description
Std. Pkg.
Carton Quantity
Wt. Lbs. Per 100
TP708
Two metal holders for mounting old-work switch boxes in all types of wall
materials
500 Sets
50 Sets
5
Std. Pkg.
Capacity Cu. In.
Wt. Lbs. Per 100
50
3.5
13
SWITCH BOX EXTENSION
TP709
Cat. #
Description
TP709
Fits snugly inside all 3" x 2" width boxes. Maximum adjustable depth 7.8".
Furnished with mounting screws.
P-300 STEEL STUD SAFETY PLATE
•
•
•
•
Meets requirement of National Electric Code
Same size as face of stud
No nails required
Protects electrical cable and copper water pipes
Cat. #
Description
TP659
2" x 31/ 2" Steel Plate
22
US: 1-866-764-5454
CAN: 1-800-265-0502
Std. Pkg.
Wt. Lbs. Per 100
100
11
Copyright© 2007 Cooper Crouse-Hinds
Steel Octagon Boxes & Ceiling Pans
31/4" OCTAGON OUTLET BOXES* – 11.5 CUBIC INCH CAPACITY
11/2" DEEP
Cat. #
TP258
TP259
Description
FOR CONDUIT – NO CLAMPS
TP256
—
TP258
Extension Ring
FOR NONMETALLIC CABLE WITH CLAMPS
TP259
"S" Bracket, Set 1/ 2"
TP260
—
TP262
With Side Nail Holes
TP264
Two Screw Ears
4
4
4
4
–
–
–
–
TP260
TP262
TP264
KNOCKOUTS
Sides
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
4 – 1/ 2"
4 – 1/ 2"
1 – 1/ 2"
—
50
50
41
31
1/ 2"
50
50
50
50
53
44
43
47
Cable,
Cable,
Cable,
Cable,
1
2
2
2
–
–
–
–
1/ 2"
1
1
1
1
1/ 2"
1/ 2"
1/ 2"
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
Steel Boxes
TP256
31/4" ROUND CELING PAN* – 4.0 CUBIC INCH CAPACITY
1/ 2"
DEEP
CLAMPS IN BOTTOM
TP266
TP270
Cat. #
Cable
TP266
4
KNOCKOUTS
Conduit
1–
TP272
Std. Unit Pkg.
Wt. Lbs. Per 100
50
30
100
100
18
18
1/ 2"
31/4"
ROUND COVERS
TP270
TP272
Flat Blank
Flat, 1/ 2" KO in Center
4" ROUND CELING PANS* – 6.0 CUBIC INCH CAPACITY
1/ 2"
DEEP
TP269
Cat. #
Description
TP269
TP267
KOs Only
KOs and Clamps
TP267
Sides
—
—
KNOCKOUTS
Bottom
5 – 1/ 2"
4 – Cable, 3 – 1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
35
39
*Weight limit for 31/ 4" and 4" octagon outlet boxes and ceiling pans is 50lbs for fixture. Not suitable for fans.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
23
Steel Octagon Boxes
4" OCTAGON OUTLET BOXES† – 15.5 CUBIC INCH CAPACITY
Steel Boxes
11/2" DEEP
FOR CONDUIT – NO CLAMPS
TP274, TP276,
TP278, TP834*
TP273
TP280
TP282
TP284, TP286
KNOCKOUTS
Cat. #
Description
TP274
TP273
TP276
TP278
TP280
TP282
—
Blank Bottom
—
—
"C" Bracket
"S" Bracket, Set 1/ 2"
Air Plenum
TP834*
For Air Plenum
Sides
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
4–
4 – 1/ 2"
4 – 3/ 4"
2 – 1/ 2", 2 – 3/ 4"
4 – 1/ 2"
3 – 1/ 2"
1/ 2"
5–
—
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
5 – 1/ 2"
5 – 1/ 2"
50
50
50
50
50
50
50
51
50
50
60
58
4 – 1/ 2"
5 – 1/ 2"
50
52
1/ 2"
OCTAGON EXTENSION RINGS – (SLOT & KEY PERMIT MOUNTING WITHOUT REMOVING BOX SCREWS)
TP284‡
—
—
50
4 – 1/ 2"
—
50
TP286‡
—
2 – 1/ 2", 2 – 3/ 4"
36
36
*For Air Plenum (No Mounting Holes)
† Weight limit for 31/ 4" and 4" octagon outlet boxes and ceiling pans is 50lbs for fixture. Not suitable for fans
‡ CSA Certified
11/2" DEEP
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP310
Cat. #
Description
TP310
TP312
TP314
—
"C" Bracket
"S" Bracket, Set 1/ 2"
24
TP312
KNOCKOUTS
Sides
4 – Cable, 2 – 1/ 2"
4 – Cable, 2 – 1/ 2"
4 – Cable, 1 – 1/ 2"
US: 1-866-764-5454
CAN: 1-800-265-0502
TP314
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
50
50
50
57
66
64
Copyright© 2007 Cooper Crouse-Hinds
Steel Octagon Boxes
4" OCTAGON OUTLET BOXES – 15.5 CUBIC INCH CAPACITY
11/2" DEEP
FOR NONMETALLIC CABLE – WITH CLAMPS
Steel Boxes
TP298
Cat. #
TP298
TP300
TP302
TP304
TP306
TP308
TP300
TP302
KNOCKOUTS
Sides
Description
—
With Side Nail Holes
"C" Bracket
"S" Bracket, Set 1/ 2"
Two Screw Ears
"F" Bracket, Set 1/ 2"
TP304
4
4
4
4
4
4
–
–
–
–
–
–
Cable,
Cable,
Cable,
Cable,
Cable,
Cable,
2
2
2
1
2
1
–
–
–
–
–
–
Bottom
1/ 2"
1
1
1
1
1
1
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
–
–
–
–
–
–
TP306
TP308
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
50
50
56
55
65
64
58
64
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
1/ 2"
4" OCTAGON OUTLET BOXES – 21.5 CUBIC INCH CAPACITY
21/8" DEEP
FOR CONDUIT – NO CLAMPS
TP288, TP290, TP294
TP292, TP838*
TP339
KNOCKOUTS
Cat. #
Description
Sides
TP288
TP290
TP292
TP294
TP339
—
—
—
—
Blank Bottom
4 – 1/ 2"
4 – 3/ 4"
2 – 1/ 2", 2 – 3/ 4"
4 – 1"
4 – 1/ 2"
3
3
3
3
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
3/ 4"
25
25
25
25
25
64
64
64
64
65
Air Plenum
TP838*
Plenum
2 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
25
62
–
–
–
–
1/ 2",
2
1/ 2", 2
1/ 2", 2
1/ 2", 2
—
–
–
–
–
3/ 4"
3/ 4"
3/ 4"
*For Air Plenum (No Mounting Holes)
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
25
Steel Octagon Boxes
4" OCTAGON OUTLET BOXES – 21.5 CUBIC INCH CAPACITY
Steel Boxes
21/8" DEEP – WITH CABLE CLAMPS
TP316
Cat. #
TP318
TP320
KNOCKOUTS
Sides
Description
TP317
TP338
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
1 – 1/ 2"
25
25
25
68
88
81
FOR ARMORED & METAL CLAD (MCI) – CABLE-CLAMPS IN EACH END
TP317
—
4 – Cable, 2 – 1/ 2"
1 – 1/ 2"
TP338
4 – Cable, 1 – 1/ 2"
1 – 1/ 2"
"S" Bracket, Set 1/ 2"
25
25
69
82
FOR NONMETALLIC CABLE
TP316
—
TP318
"C" Bracket
TP320
"S" Bracket, Set 1/ 2"
26
4 – Cable, 2 – 1/ 2"
4 – Cable, 2 – 1/ 2"
4 – Cable, 1 – 1/ 2"
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Steel Octagon Covers & Accessories
4" OCTAGON BOX COVERS – CUBIC CAPACITY (SEE BELOW)
TP323
TP326, TP331,
TP332, TP333
TP328
TP329
TP335
TP334
TP336
TP330
Cat. #
Description
Capacity Cu. In.
Std. Unit Pkg.
Wt. Lbs. Per 100
TP322†
TP323†
TP333
TP332
TP326
TP331
TP328†
TP330
TP329†
TP335
TP334
TP336
Flat Blank – Octagon Shape
Flat Blank – Round Shape
Raised 1", Open With Ears 23/ 4"
Raised 1/ 2", Open With Ears 23/ 4"
Raised 5/ 8", Open With Ears 23/ 4"
Raised 3/ 4", Open With Ears 23/ 4"
Flat With 1/ 2" KO – Octagon Shape
Raised 5/ 8", With 1/ 2" KO
Flat With 1/ 2" KO – Round Shape
Flat, For Toggle Switch
Flat, Single Receptacle 113/ 32"
Flat, For Duplex Receptacle
—
—
7.0
3.3
3.8
5.0
—
3.8
—
—
—
—
50
50
25
50
50
50
50
50
50
50
50
50
22
24
30
22
20
26
22
31
24
23
21
18
Air Plenum
TP853*
Flat, Blank With PVC Gasket
—
50
24
Steel Boxes
TP322
TP853*
*For Air Plenum (No Mounting Holes)
†CSA Certified
ADJUSTABLE BAR HANGERS
HOLDING PRONG . . . HOLDS BOX IN PLACE FOR NAILING – DESIGN RESISTS BENDING
AND TWISTING – TP354 AND TP356 HAVE LOCKING TABS TO HOLD BAR IN POSITION
Weight Limits: 35 lbs. at 16", 15 lbs. at 24".
TP356
TP354
Cat. #
Stud Spacing
Length
Stud
Std. Unit Pkg.
Wt. Lbs. Per 100
TP354
TP356
16" & 24"
16" & 24"
14" – 221/ 2"
14" – 221/ 2"
Yes
—
50
50
43
41
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
27
Ceiling Fan Box And Supports
Steel Boxes
CEILING FAN BOXES –
CUBIC INCH CAPACITY (SEE BELOW)
Weight Limits: TP261 – 35 lbs. max.
for fans, 50 lbs. max. for fixture.
TP301 – Fan is supported
independent of outlet box, mounting
screws go through box and into
joist. Box will support fans up to 70
lbs. and fixtures up to 90 lbs. TP275
– 70 lbs, max. for fans, 90 lbs. max
for fixtures.
TP275
Cat. #
Description
TP275
11/ 2" Deep, Clamps
and Mounting
Screws (polybagged)
TP261
5/ 8" Deep with
External Clamp and
Mounting Screws
(polybagged)
8.0
TP301*
1/ 2" Deep, 4" Round,
with NM Snap-In
Connector, mtg.
screws, Protective
Cover (no bag)
6.8
TP261
Cubic In. Capacity
15.5
KNOCKOUTS
Sides
Bottom
TP301
WEIGHT LIMITS
Fans Fixtures
Std. Unit Pkg.
Wt. Lbs. Per 100
4 – Cable, 2 – 1/ 2" 1 – 1/ 2"
20
66.6
70 lbs.
90 lbs.
—
2 – 1/ 2"
20
50
35 lbs.
50 lbs.
—
3 – 1/ 2"
20
51
70 lbs.* 90 lbs.*
*TP301 fan is supported independent of outlet box
CEILING FAN BOXES AND
SUPPORTS
Weight Limits: Up to 35 lbs. for fans.
Up to 50 lbs. for fixtures.
TP315
Cat. #
Description
Stud Spacing
TP379
Capacity. Cu. In.
KNOCKOUTS
Bottom Side
1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
1/ 2"
12
192
12
207
TP315†
Fan Box with New Work Bar Hanger
16" – 24"
15.5
2–
TP379
11/ 2" Deep with Fan Brace Old Work
Bar Hanger
16" – 24"
15.5
2 – 1/ 2" 4 – 1/ 2"
2–
†TP315 comes with Romex clamp installed on one side. The other 3 sides have a 1/ 2" KO, a bagged MC clamp and screw and a bagged plastic NM connector
CEILING FAN BOXES – PVC
Weight Limits: Fans and fixtures are supported independent of outlet
box. Mounting screws go through box and into joist. Box will support up
to 70 lbs. for fans and 90 lbs. for fixtures. Provided with Romex
connector
TP1300
Cat. #
Description
Capacity Cu. In.
Knockouts
Integral Clamp
Std. Unit Pkg.
Wt. Lbs. Per 100
TP1300
41/ 16" diam., 1/ 2" deep pan section, 4"
deep overall – with mtg. hardware &
external clamp, protective cover
14.0
3 – 1/ 2"
1
24
34
TP1300 1
Same as 1300, packed in counter
display
14.0
3 – 1/ 2"
1
24
35
28
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Ceiling Fan Boxes & Steel Octagon Boxes
NONMETALLIC CEILING FAN BOXES
•
•
•
•
Made of heavy-duty, engineered thermoplastic material
Offers the labor-saving feature of quick entry and integral clamping
Eliminates the need to use a screwdriver to break open pry-outs
The easy access entry-point serves as a wire clamp, eliminating time
required to mechanically secure the wire to the box
TP16511
TP16511
Diameter
Mounting Method
Capacity Cu. In.
No. of Clamp Openings
Std. Unit Pkg.
Wt. Lbs. Per 100
4"
Nails only
22.5
6
25
21
4" OCTAGON BOX AND ADJUSTABLE BAR SETS – 15.5 CUBIC INCH CAPACITY
11/2" DEEP BOX SETS
Weight Limits: 35 lbs. at 16", 15 lbs. at 24"
Cat. #
TP376
TP372*
TP377
TP368
Stud
Std. Unit Pkg.
Wt. Lbs. Per 100
FOR CONDUIT – NO CLAMPS
TP372*
16" – 24"
Stud Spacing
Yes
25
85
FOR NONMETALLIC CABLE – WITH CLAMPS
TP376
16" – 24"
TP377
16" – 24"
Yes
—
25
25
104
102
25
100
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP368
16" – 24"
Yes
*4" Octagon Box and Adjustable Bar Sets have 1/ 2" KOs for conduit
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
29
Steel Boxes
Cat. #
Steel Square Boxes
4" SQUARE OUTLET BOXES – 18.0 CUBIC INCH CAPACITY
Steel Boxes
11/4" DEEP – FOR CONDUIT
TP408
Cat. #
TP408
30
Bracket
—
Description
Drawn
KNOCKOUTS
Sides
Bottom
12 –
US: 1-866-764-5454
1/ 2"
CAN: 1-800-265-0502
5–
1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
50
61
Copyright© 2007 Cooper Crouse-Hinds
Steel Square Boxes
4" SQUARE OUTLET BOXES – 22.0 CUBIC INCH CAPACITY (WELDED)†
21.0 CUBIC INCH CAPACITY (DRAWN)
11/2" DEEP – FOR CONDUIT
Steel Boxes
TP404/TP404PF
TP425
TP467
TP410
TP412
TP839*
TP414
TP469
TP830*
TP405
TP418
TP423
KNOCKOUTS
Metal Stud
Sizes
Bracket
TP404
TP404 PF‡
TP425
TP423
TP405
TP410
TP412
TP414
TP418
TP467
TP469
—
—
—
All
—
—
—
—
—
—
ALL
—
—
"VP"
"VMS"
—
—
—
—
"F", Set Flush
—
"VMS"
Welded
Welded
Welded
Welded
Drawn
Drawn
Drawn
Drawn
Welded
Welded
Welded
8 – 1/ 2", 4 – 1/ 2" + 3/ 4" E
8 – 1/ 2", 4 – 1/ 2" + 3/ 4" E
6 – 1/ 2", 3 – 1/ 2" + 3/ 4" E
6 – 1/ 2", 3 – 1/ 2" + 3/ 4" E
4 – 1/ 2", 6 – 1/ 2" & 3/ 4" C
12 – 1/ 2"
8 – 3/ 4"
1
8 – / 2", 4 – 3/ 4"
6 – 1/ 2", 3 – 1/ 2" + 3/ 4" E
8 – 3/ 4"
6 – 3/ 4"
Air Plenum
TP830*
TP839*
—
—
—
—
Drawn
Drawn
8 – 1/ 2", 4 – 3/ 4"
8 – 3/ 4" C
Cat. #
Description
Sides
Bottom
2 – 1/ 2" + 3/ 4"
2 – 1/ 2" + 3/ 4"
1/ 2", 2 – 1/ 2" + 3/ 4"
1/ 2", 2 – 1/ 2" + 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
5 – 1/ 2"
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
2 – 1/ 2", 2 – 1/ 2" + 3/ 4"
2 – 1/ 2", 2 – 1/ 2" + 3/ 4"
2 – 1/ 2", 2 – 1/ 2" + 3/ 4"
2
2
2
2
–
–
–
–
1/ 2",
1/ 2",
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
E
E
E
E
E
E
E
Std. Unit
Pkg.
Wt. Lbs.
Per 100
50
50
25
25
50
50
50
50
25
50
25
72
72
82
81
67
67
67
67
84
72
81
50
50
72
72
*For Air Plenum (No Mounting Holes)
† All welded 4" square outlet boxes have a raised dimple for ground screw
‡ TP404PF includes ground screw with pigtail lead
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
31
Steel Square Boxes
4" SQUARE OUTLET BOXES – 22.0 CUBIC INCH CAPACITY
Steel Boxes
11/2" DEEP
FOR NONMETALLIC CABLE – CLAMPS IN EACH END
TP444
Cat. #
Bracket
TP449
TP444
TP446
TP445
"VMS"
—
"F", Set Flush
"VP"
TP449
TP446
KNOCKOUTS
Sides
Description
Welded
Welded
Welded
Welded
4
4
4
4
–
–
–
–
Cable,
Cable,
Cable,
Cable,
2
4
2
2
–
–
–
–
1/ 2",
1
1/ 2", 2
1/ 2", 1
1/ 2", 1
–
–
–
–
1/ 2"
&
1/ 2" &
1/ 2" &
1/ 2" &
3/ 4"
E
3/ 4" E
3/ 4" E
3/ 4" E
TP445
Bottom
1
1
1
1
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
1/ 2"
Std. Unit Pkg.
Wt. Lbs. Per 100
25
50
25
25
85
77
88
85
4" SQUARE OUTLET BOXES – 22.0 CUBIC INCH CAPACITY
11/2" DEEP
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP454
Cat. #
Bracket
TP459
TP454
TP456
TP461
"VMS"
—
"F", Set Flush
"VP"
32
TP456
TP459
KNOCKOUTS
Sides
Description
Welded
Welded
Welded
Welded
4
4
4
4
–
–
–
–
US: 1-866-764-5454
Cable,
Cable,
Cable,
Cable,
2
4
2
2
–
–
–
–
1/ 2",
1
1/ 2", 2
1/ 2", 1
1/ 2", 1
CAN: 1-800-265-0502
–
–
–
–
1/ 2"
&
1/ 2" &
1/ 2" &
1/ 2" &
3/ 4"
E
3/ 4" E
3/ 4" E
3/ 4" E
TP461
Bottom
1
1
1
1
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
1/ 2"
Copyright© 2007 Cooper Crouse-Hinds
Std. Unit Pkg.
Wt. Lbs. Per 100
25
50
25
25
89
81
92
89
Steel Square Boxes
4" SQUARE OUTLET BOXES – 30.3 CUBIC INCH CAPACITY
21/8" DEEP WITH CONDUIT KOs
TP434
TP438
TP831*
TP432
TP436
TP840*
TP437
Steel Boxes
TP403/TP403PF
TP451
KNOCKOUTS
Cat. #
Bracket
Description
Sides
1/ 2",
1/ 2"
Bottom
3/ 4"
TP403
TP403 PF†
TP432
TP436
TP434
TP438
TP451
TP437
—
—
—
—
—
—
"VMS"
"VP"
Welded
Welded
Welded
Welded
Drawn
Drawn
Welded
Welded
4–
&
E
8–
8 – 1/ 2", 4 – 1/ 2" & 3/ 4" E
8 – 3/ 4"
8 – 1"
8 – 1/ 2", 4 – 3/ 4"
4 – 1/ 2", 6 – 1/ 2" & 3/ 4" C
6 – 1/ 2", 3 – 1/ 2" & 3/ 4" E
6 – 1/ 2", 3 – 1/ 2" & 3/ 4" E
Air Plenum
TP831*
TP840*
—
—
Drawn
Drawn
8 – 1/ 2", 4 – 3/ 4"
8 – 3/ 4"
2
2
2
2
1/ 2",
1/ 2"
3/ 4"
–
2–
&
– 1/ 2", 2 – 1/ 2" & 3/ 4"
– 1/ 2", 2 – 1/ 2" & 3/ 4"
– 1/ 2", 2 – 1/ 2" & 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
2 – 1/ 2", 2 – 1/ 2" & 3/ 4"
2 – 1/ 2", 2 – 1/ 2" & 3/ 4"
Std. Unit Pkg.
Wt. Lbs. Per 100
25
25
25
25
25
25
25
25
84
84
84
84
84
84
96
98
25
25
90
90
E
E
E
E
E
E
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
*For Air Plenum (No Mounting Holes)
†TP403PF includes ground screw with pigtail lead
21/8" DEEP – 30.3 CUBIC INCH CAPACITY
FOR NONMETALLIC CABLE CLAMPS
TP450
Cat. #
Bracket
TP450
TP452
—
"VMS"
TP452
KNOCKOUTS
Sides
Description
Welded
Welded
4 – Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" E
4 – Cable, 2 – 1/ 2", 1 – 1/ 2" & 3/ 4" E
US: 1-866-764-5454
CAN: 1-800-265-0502
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
25
25
90
104
Copyright© 2007 Cooper Crouse-Hinds
33
Steel Square Boxes
4" SQUARE OUTLET BOXES – 30.3 CUBIC INCH CAPACITY
Steel Boxes
21/8" DEEP
FOR ARMORED & METAL CLAD (MCI) CABLE – CLAMPS IN EACH END
TP431
Cat. #
Metal Stud Sizes
TP431
TP440
—
All
TP440
KNOCKOUTS
Sides
Bracket Description
—
"VMS"
Welded
Welded
4 – Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4" E
4 – Cable, 2 – 1/ 2", 1 – 1/ 2" & 3/ 4" E
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
1 – 1/ 2"
1 – 1/ 2"
25
25
91
103
4" SQUARE TWO–DEVICE BOXES – 30.3 CUBIC INCH CAPACITY
21/8" DEEP
TP391
Cat. #
Bracket
TP391
TP393
TP395
"VS"
—
—
34
TP393, TP395
Description
Drawn
Drawn
Drawn
Sides
KNOCKOUTS
Bottom
6 – 1/ 2", 3 – 3/ 4"
12 – 1/ 2"
8 – 1/ 2", 4 – 3/ 4"
US: 1-866-764-5454
CAN: 1-800-265-0502
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
Std. Unit Pkg.
Wt. Lbs. Per 100
25
25
25
95
84
84
Copyright© 2007 Cooper Crouse-Hinds
Steel Square Boxes & Covers
4" SQUARE EXTENSION RINGS – 21.0 CUBIC INCH CAPACITY
11/2" DEEP WITH CONDUIT KNOCKOUTS
Cat. #
TP424
TP422
TP426
TP428
TP833*
TP422
KNOCKOUTS
Sides
12 – 1/ 2"
8 – 1/ 2", 4 – 1/ 2" + 3/ 4" E
8 – 3/ 4"
8 – 1/ 2", 4 – 3/ 4"
8 – 1/ 2", 4 – 3/ 4"
21/8" DEEP WITH CONDUIT KNOCKOUTS
TP841*
8 – 1/ 2", 4 – 3/ 4"
TP426
Steel Boxes
TP424
TP428,
TP833*, TP841*
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
—
—
—
—
—
50
50
50
50
50
46
50
46
46
48
—
25
66
*For Air Plenum (No Mounting Holes). Requires the use of TP854, purchased separately.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
35
Steel Square Boxes & Covers
Features:
Steel Boxes
• Special spring steel allows for quick and easy tool-free installation.
• Mounts on either side of the stud and can be easily removed or
repositioned.
• Sleek, low profile mounting bracket.
• Far side support bracket provides support for boxes in 21/ 4" - 4"
studs.
• Far side support snaps easily onto box and is secured in place by
plaster ring.
• Available in shallow and deep boxes for use with conduit,
armored/metal clad cable or Nonmetallic sheathed cable.
• Steel bracket for lifting larger enclosures during installation supplied
as standard.
4" SQUARE BRACKETED OUTLET BOXES
TP404SSB
TP444SSB
TP454SSB
TP450SSB
TP431SSB
TP563SSB
TP403SSB
KNOCKOUTS
Cat. #
Box
Size
TP404SSB
TP444SSB
TP454SSB
TP403SSB
TP450SSB
TP431SSB
TP563SSB
4"
4"
4"
4"
4"
4"
411/ 16"
36
Box
Depth For Use With
11/ 2"
11/ 2"
11/ 2"
21/ 8"
21/ 8"
21/ 8"
21/ 8"
Cubic Inch
Capacity
Conduit
Nonmetallic Sheathed Cable
Armored/Metal Clad Cable
Conduit
Nonmetallic Sheathed Cable
Armored/Metal Clad Cable
Conduit
US: 1-866-764-5454
22.0
22.0
22.0
30.3
30.3
30.3
42.0
CAN: 1-800-265-0502
Sides
4–
4–
4–
4–
8 – 1/ 2", 4 – 1/ 2" & 3/ 4" E
Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4"
Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4"
8 – 1/ 2", 4 – 1/ 2" & 3/ 4" E
Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4"
Cable, 4 – 1/ 2", 2 – 1/ 2" & 3/ 4"
6 – 1/ 2", 6 – 1/ 2" & 3/ 4" C
Copyright© 2007 Cooper Crouse-Hinds
Bottom
E
E
E
E
2 – 1/ 2", 2 – 1/ 2" & 3/ 4" E
1 – 1/ 2"
1 – 1/ 2"
1
2 – / 2", 2 – 1/ 2" & 3/ 4" E
1 – 1/ 2"
1 – 1/ 2"
3 – 1/ 2", 2 – 3/ 4"
Steel Square Boxes & Covers
UNI-MOUNT™ COVERS
The Unimount combines the features of a mounting device plate with
those of a box support; giving you one universal plate for all of your
needs. Specifically designed for use with metal or wood studs:
Guide tabs ensure consistant alignment on stud
Stud alignment hole ensures consistent mounting height
Rigid bracket design elminates the need for far side support
Available as a single or two device cover
Universal design fits all 4" Square boxes
Available in 1/ 2", 5/ 6" and 3/ 4" raised.
Can be ordered preassembled to popular 4" square boxes.
Fast and easy installation
Can be used in multiple applications, resulting in less items to stock.
Less labor intensive.
Less material handling.
No multiple assemblies to handle.
Can be used in Class 2 communications outlets for low voltage
without a box.
• UL listed and CSA certified.*
Steel Boxes
•
•
•
•
•
•
•
•
•
•
•
•
•
Single Gang
Cat. #
Description
Capacity Cu. In.
Std. Unit Pkg.
Wt. Lbs. Per 100
3.8
4.3
5.5
50
50
50
43
46
50
6
8
9
50
50
50
38
52
54
—
1000
.5
SINGLE GANG
1/ 2" Raised
TP30000
5/ 8" Raised
TP31000
3/ 4" Raised
TP32000
TWO GANG
TP35000
TP36000
TP37000
Two Gang
1/ 2"
Raised
Raised
3/ 4" Raised
5/ 8"
LOW PROFILE SCREWS
TP710
L.P. Screws
* CSA requires a far side support.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
37
Steel Square Boxes & Covers
PRE-FABRICATED BOXES
Cooper Crouse-Hinds Pre-Fabricated Boxes take labor savings to a
whole new level! Includes the Uni-Mount™ cover attached to a 4"
square box with ground screw and lead installed.
Step 1 – Receive Uni-Mount™ Pre-Fabricated Box (Includes Uni-Mount
cover attached to box with ground screw + lead installed)
Steel Boxes
Step 2 – Attach to wood or metal stud. You're done!
TP404
11/ 2" Deep – Welded
22.0" Cubic Capacity
TP403
21/ 8" Deep – Welded
22.0" Cubic Capacity
TP436
21/ 8" Deep – Welded
30.3" Cubic Capacity
Cat. #
Description
Pre-Fabricated Box, Cover, Ground Screw and Lead Assembly
TP30404PF
TP31404PF
TP31436PF
TP31467PF
TP32404PF
TP32454PF
TP35404PF
TP36404PF
TP36467PF
TP37404PF
TP30403PF
TP31403PF
TP32403PF
TP35403PF
TP36403PF
TP37403PF
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
11/ 2" Welded
21/ 8" Welded
21/ 8" Welded
21/ 8" Welded
21/ 8" Welded
21/ 8" Welded
21/ 8" Welded
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
Box,
1/ 2"
5/ 8"
5/ 8"
5/ 8"
3/ 4"
3/ 4"
1/ 2"
5/ 8"
5/ 8"
3/ 4"
1/ 2"
5/ 8"
3/ 4"
1/ 2"
5/ 8"
3/ 4"
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Single Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Raised Two Gang Uni-Mount Cover, ground screw and lead
Note: The last three digits in the above catalog numbers designate the box type. See line art above.
38
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
TP467
11/ 2" Deep – Welded
22.0" Cubic Capacity
Capacity
Cu. In.
Std. Unit
Pkg.
Wt. Lbs.
Per 100
25.8
26.3
26.3
26.3
27.5
27.5
28.0
30.0
30.0
31.0
34.1
34.6
35.8
36.3
38.3
39.3
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
115
118
130
113
122
121
110
124
119
126
107
110
114
102
116
118
Steel Square Boxes & Covers
PREASSEMBLED BOXES
The Uni-Mount™ cover is available preassembled to four popular 4" square boxes for even greater labor
savings and reduced costs.
TP434
21/ 8" Deep – Welded
30.3" Cubic Capacity
TP454
11/ 2" Deep – Welded
22.0" Cubic Capacity
Cat. #
Description
Pre-Fabricated Box, Cover, Ground Screw and Lead Assembly
For Conduit
TP30414
TP31414
TP32414
TP35414
TP36414
TP37414
TP30434
TP31434
TP32434
TP35434
TP36434
TP37434
11/ 2"
11/ 2"
11/ 2"
11/ 2"
11/ 2"
11/ 2"
21/ 8"
21/ 8"
21/ 8"
21/ 8"
21/ 8"
21/ 8"
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Drawn
Box
Box
Box
Box
Box
Box
Box
Box
Box
Box
Box
Box
assembled
assembled
assembled
assembled
assembled
assembled
assembled
assembled
assembled
assembled
assembled
assembled
to
to
to
to
to
to
to
to
to
to
to
to
1/ 2"
5/ 8"
3/ 4"
1/ 2"
5/ 8"
3/ 4"
1/ 2"
5/ 8"
3/ 4"
1/ 2"
5/ 8"
3/ 4"
Steel Boxes
TP414
11/ 2" Deep – Welded
21.0" Cubic Capacity
TP431
21/ 8" Deep – Welded
30.3" Cubic Capacity
Capacity
Cu. In.
Std. Unit
Pkg.
Wt. Lbs.
Per 100
24.8
25.3
26.5
27.0
29.0
30.0
34.1
34.6
35.8
36.3
38.3
39.3
25
25
25
25
25
25
25
25
25
25
25
25
110
113
117
105
119
121
127
130
134
122
136
138
24.8
25.3
26.5
27.0
29.0
30.0
34.1
34.6
35.8
36.3
38.3
39.3
25
25
25
25
25
25
25
25
25
25
25
25
114
117
121
109
123
125
134
137
141
129
143
145
Raised Single Gang Uni-Mount Cover
Raised Single Gang Uni-Mount Cover
Raised Single Gang Uni-Mount Cover
Raised Two Gang Uni-Mount Cover
Raised Two Gang Uni-Mount Cover
Raised Two Gang Uni-Mount Cover
Raised Single Gang Uni-Mount Cover
Raised Single Gang Uni-Mount Cover
Raised Single Gang Uni-Mount Cover
Raised Two Gang Uni-Mount Cover
Raised Two Gang Uni-Mount Cover
Raised Two Gang Uni-Mount Cover
For AC/MC Cable
TP30454
11/ 2" Welded Box assembled to 1/ 2" Raised Single Gang Uni-Mount Cover
TP31454
11/ 2" Welded Box assembled to 5/ 8" Raised Single Gang Uni-Mount Cover
TP32454
11/ 2" Welded Box assembled to 3/ 4" Raised Single Gang Uni-Mount Cover
TP35454
11/ 2" Welded Box assembled to 1/ 2" Raised Two Gang Uni-Mount Cover
TP36454
11/ 2" Welded Box assembled to 5/ 8" Raised Two Gang Uni-Mount Cover
TP37454
11/ 2" Welded Box assembled to 3/ 4" Raised Two Gang Uni-Mount Cover
TP30431
21/ 8" Welded Box assembled to 1/ 2" Raised Single Gang Uni-Mount Cover
TP31431
21/ 8" Welded Box assembled to 5/ 8" Raised Single Gang Uni-Mount Cover
TP32431
21/ 8" Welded Box assembled to 3/ 4" Raised Single Gang Uni-Mount Cover
TP35431
21/ 8" Welded Box assembled to 1/ 2" Raised Two Gang Uni-Mount Cover
TP36431
21/ 8" Welded Box assembled to 5/ 8" Raised Two Gang Uni-Mount Cover
TP37431
21/ 8" Welded Box assembled to 3/ 4" Raised Two Gang Uni-Mount Cover
Note: The last three digits in the above catalog numbers designate the box type. See line art above.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
39
Steel Square Covers
COVERS FOR 4" SQUARE BOXES – CUBIC INCH CAPACITY (SEE BELOW)
Steel Boxes
#8-32 screw used on covers
TP472
TP474
TP478
TP473, TP475, TP476,
TP477, TP479, TP483
TP850*
TP854*
Cat. #
Description
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
TP472†
TP474
TP478†
TP473
TP476†
TP477
TP475
TP479
TP483
Flat Blank
Flat Blank, Open With Ears 23/ 4"
Flat with 1/ 2", ko
Raised 1/ 4", Open With Ears 23/ 4"
Raised 1/ 2", Open With Ears 23/ 4"
Raised 5/ 8", Open With Ears 23/ 4"
Raised 3/ 4", Open With Ears 23/ 4"
Raised 1", Open With Ears 23/ 4"
Raised 11/ 4", Open With Ears 23/ 4"
50
50
50
50
50
50
25
25
25
31
21
31
23
26
27
31
34
37
—
—
—
1.3
4.0
5.0
6.0
7.0
8.5
Air Plenum
TP850*
TP854*
Flat Blank Gasketed With Captive Screws
Flat Ring Double Gasketed
25
25
31
12
—
—
*For Air Plenum (No Mounting Holes)
†CSA Certified
ONE DEVICE
TP480
TP482, TP484, TP486,
TP488, TP489, TP490
Cat. #
Description
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
TP480
TP482
TP484
TP489
TP486
TP488
TP490
Flat
1/ 4" Raised
1/ 2" Raised
5/ 8" Raised
3/ 4" Raised
1" Raised
11/ 4" Raised
50
50
50
50
50
50
25
20
21
23
26
30
34
39
—
1.8
3.5
4.3
5.5
6.8
8.8
40
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Steel Square Covers
TWO DEVICE
TP494
TP494
TP496‡
TP498‡
TP499‡
TP500‡
TP501
TP502
Description
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
Flat
Raised
1/ 2" Raised
5/ 8" Raised
3/ 4" Raised
11/ 4" Raised
1" Raised
50
50
50
50
50
25
25
12
13
18
22
24
31
30
—
3.0
6.0
8.0
9.0
14.0
11.7
1/ 4"
Steel Boxes
Cat. #
TP496, TP488, TP499,
TP500, TP501, TP502
‡ Slotted design for use with 4" square box partitions
SURFACE COVERS FOR 4" SQUARE BOXES – 5.5 CUBIC INCH CAPACITY
RAISED 1/2"
TP503
TP504
TP506
TP508
TP510
TP512
TP516
TP509
TP518
TP513
TP511
TP515
TP517
Cat. #
Description
TP503†
TP504†
TP506†
TP508
TP510
TP512
TP507
TP514
TP519†
TP516
TP509
TP518
TP513
TP511
TP515
TP517
Raised Blank
For One Toggle Switch, One Single Receptacle 113/ 32" Dia.
For One Toggle Switch, One Duplex Receptacle
For Two Toggle Switches
For Two Duplex Receptacles
For One Toggle Switch
For One 20 Amp, Single Receptacle 119/ 32" Dia.
For One Single Receptacle 113/ 32" Dia.
For One 30 Amp. Twist-Lock Single Receptacle 123/ 32" Dia.
For One Duplex Receptacle
For One 30 – 60 Amp. Receptacle (4-wire) 27/ 16" Dia.
For One 30 – 50 Amp. Receptacle 29/ 64" Dia.
For One GFCI Receptacle
For Two GFCI Receptacles
For One Toggle Switch, One GFCI Receptacle
For One Duplex Receptacle, One GFCI Receptacle
TP507
TP514
TP519
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
35
31
31
35
26
35
37
34
37
31
23
34
31
26
31
26
† CSA Certified
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
41
Steel Square Boxes
Steel Boxes
TILE WALL COVERS FOR 4" SQUARE BOXES – CUBIC INCH CAPACITY (SEE BELOW)
TP524
TP534
Applications:
• Typically used with tile or brick
Cat. #
Description
ONE DEVICE
TP520
TP522
TP524
TP526
TP528
TP530
TWO DEVICE
TP532
TP534
TP536
TP538
TP540
TP542
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
1/ 2"
Raised
Raised
1" Raised
11/ 4" Raised
11/ 2" Raised
2" Raised
50
50
50
25
25
25
30
36
40
46
50
62
3.7
5.5
7.4
9.2
11.0
14.7
1/ 2"
10
10
10
10
10
10
24
30
36
44
50
66
5
7.8
10.3
13
15.5
20.8
3/ 4"
Raised
Raised
1" Raised
11/ 4" Raised
11/ 2" Raised
2" Raised
3/ 4"
4" SQUARE BOX PARTITIONS
TP860
Cat. #
TP861
TP862
Std. Unit Pkg.
Wt. Lbs. Per 100
FOR 11/2" DEEP BOX WITH SQUARE CUT TILE WALL TWO-GANG COVERS
TP860
For 1/ 2", 3/ 4", 1" Raised Covers
TP861
For 11/ 4", 11/ 2", 2" Raised Covers
25
25
13
18
FOR 21/8" DEEP BOX WITH SQUARE CUT TILE WALL TWO-GANG COVERS
TP862
For 1/ 2", 3/ 4", 1" Raised Covers
TP863
For 11/ 4", 11/ 2", 2" Raised Covers
25
25
16
21
42
Description
TP863
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Steel Square Boxes
411/16" SQUARE OUTLET BOXES – 29.5 CUBIC INCH CAPACITY
11/2" DEEP WITH CONDUIT KOs
Steel Boxes
TP548
TP550
KNOCKOUTS
Cat. #
Sides
Bottom
Std. Unit Pkg.
Wt. Lbs. Per 100
TP548
TP549
8 – 1/ 2", 4 – 3/ 4"
1
6 – / 2", 6 – 1/ 2" & 3/ 4" C
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
25
25
84
84
—
25
66
411/16" SQUARE EXTENSION RING
TP550
8 – 1/ 2", 4 – 3/ 4"
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
43
Steel Square Boxes
411/16" SQUARE OUTLET BOXES – 42.0 CUBIC INCH CAPACITY
Steel Boxes
21/8" DEEP WITH CONDUIT KOs
TP563
TP554
TP842*
TP556
TP832*
TP558
TP835*
TP560
TP836*
TP562
TP557
TP564
TP837*
KNOCKOUTS
Cat. #
Brackets
TP563
TP554
TP556
TP558
TP560
TP562
TP557
Air Plenum
TP835*
TP836*
TP842*
TP832*
411/16",
TP564
—
—
—
—
—
"VS"
—
6–
&
C
8 – 3/ 4"
8 – 1/ 2", 4 – 3/ 4"
4 – 3/ 4", 4 – 1"
8 – 1"
4 – 1 – 1/ 4"
4 – 1/ 2", 5 – 1/ 2" & 3/ 4" C
3
3
3
3
3
3
3
–
–
–
–
–
–
–
—
—
—
—
4 – 3/ 4", 4 – 1"
8 – 1"
12 – 3/ 4"
8 – 1/ 2", 4 – 3/ 4"
3
3
3
3
–
–
–
–
1/ 2",
—
6–
1/ 2",
1/ 2"
Bottom
1/ 2",
SQUARE EXTENSION RING
—
Air Plenum
TP837*
Sides
3/ 4"
2
2
2
2
2
2
2
–
–
–
–
–
–
–
3/ 4"
2
2
1/ 2", 2
1/ 2", 2
–
–
–
–
3/ 4"
1/ 2",
1/ 2",
1/ 2",
1/ 2",
1/ 2",
1/ 2",
1/ 2",
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
Std. Unit Pkg.
Wt. Lbs. Per 100
25
25
25
25
25
25
25
104
104
104
104
104
104
120
25
25
25
25
115
115
115
115
8 – 1/ 2", 4 – 3/ 4"
—
25
84
8 – 1/ 2", 4 – 3/ 4"
—
25
115
*For Air Plenum (No Mounting Holes)
Note:
44
TP837 requires the use of TP852, purchased separately.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Steel Square Covers
411/16" SQUARES COVERS – CUBIC INCH CAPACITY (SEE BELOW)
TP569, TP570, TP571,
TP573, TP575
TP574, – TP582,
TP529, TP531
TP584, TP586, TP589,
TP593, TP541, TP543
TP851*
TP852*
Cat. #
Description
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
TP568†
TP569
TP570
TP571
TP572†
TP573
TP575
Flat Blank
1/ 2" Raised, With Ears 23/ 4"
Raised 5/ 8", With Ears 23/ 4"
3/ 4" Raised, With Ears 23/ 4"
Flat, With 1/ 2" KO
1" Raised, With Ears 23/ 4"
11/ 4" Raised, With Ears 23/ 4"
25
25
25
25
25
25
25
40
36
38
40
40
44
48
—
3.3
3.8
5.0
—
7.0
9.0
Air Plenum
TP851*
TP852
Flat Blank Gasketed Captive Screws
Flat Ring Double Gasketed
50
25
42
20
—
—
ONE DEVICE
TP574
TP576
TP578
TP579
TP580
TP582
TP529
TP531
1/ 4"
Raised
Raised
3/ 4" Raised
5/ 8" Raised
1" Raised
11/ 4" Raised
11/ 2" Raised
2" Raised
25
25
25
25
25
25
25
25
32
36
42
39
46
52
64
76
1.8
3.3
5.0
4.3
6.8
8.8
11.3
15.0
TWO DEVICE
TP590
TP583
TP584
TP587
TP586
TP589
TP593
TP541
TP543
Flat
1/ 4" Raised
1/ 2" Raised
5/ 8" Raised
3/ 4" Raised
1" Raised
11/ 4" Raised
11/ 2" Raised
2" Raised
25
25
25
25
25
25
25
25
25
21
26
30
32
34
38
42
63
79
—
3.0
6.0
8.0
8.8
11.7
14.0
18.8
24.5
1/ 2"
Steel Boxes
TP568
*For Air Plenum (No Mounting Holes)
†CSA Certified
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
45
Steel Square Covers
411/16" SQUARE SURFACE COVERS – 9.0 CUBIC INCH CAPACITY
DEEP
Steel Boxes
1/ 2"
TP720
TP722
TP724
TP730
TP736
TP726
TP728
TP732
TP734
TP738
Cat. #
Description
TP720
TP722
TP724
TP730
TP736
TP726
TP728
TP732
TP734
TP738
TP741
For One Toggle Switch
For One Duplex Receptacle
For One Single Receptacle 113/ 32" Dia.
For One 20 Amp Single Receptacle 1.620" Dia.
For One 1.730" Dia. Power Outlet
For Two Toggle Switches
For Two Duplex Receptacles
For One 2.125" Dia. Range/Dryer Receptacle
For One 2.480" Dia. Power Outlet
For One Ground Fault Interrupter
For Two GFI Receptacles
46
US: 1-866-764-5454
CAN: 1-800-265-0502
Std. Unit Pkg.
Wt. Lbs. Per 100
10
10
10
10
10
10
10
10
10
10
10
52
49
53
50
51
52
44
48
45
45
43
Copyright© 2007 Cooper Crouse-Hinds
Steel Utility Boxes & Covers
UTILITY BOXES – CUBIC INCH CAPACITY (SEE BELOW)
4" LONG × 21/8" WIDE
Cat. #
TP591
Bracket
TP592, TP600,
TP602
KNOCKOUTS
Sides
Bottom
TP598
TP594, TP596,
TP604, TP606,
TP595 (41/8" × 23/8")
Std. Unit Pkg.
Wt. Lbs. Per 100
3 – 1/ 2"
50
40
3 – 1/ 2"
3 – 1/ 2"
50
50
42
51
50
36
50
50
50
50
50
60
17/8" DEEP EXTENSION RINGS – 13.0 CUBIC INCH CAPACTIY
TP600
—
—
8 – 1/ 2"
—
TP602
—
6 – 3/ 4"
50
50
41
41
21/8" DEEP – 14.5 CUBIC INCH CAPACITY
TP604
—
8 – 1/ 2"
TP606
—
6 – 3/ 4"
TP608*
"S", Set 1/ 2"
5 – 1/ 2"
3 – 1/ 2"
3 – 1/ 2"
3 – 1/ 2"
50
50
50
56
56
66
21/8" DEEP – 18.5 CUBIC INCH CAPACITY
TP595
—
8 – 1/ 2"
3 – 1/ 2"
50
60
11/4" DEEP – 8.5 CUBIC INCH CAPACITY
TP647
—
8 – 1/ 2"
11/2"
DEEP – 10.3 CUBIC INCH CAPACITY
TP588
—
8 – 1/ 2"
TP591
"F", Set 1/ 4"
5 – 1/ 2"
11/2" DEEP EXTENSION RINGS – 10.3 CUBIC INCH CAPACITY
—
TP592
—
8 – 1/ 2"
17/8"
DEEP – 13.0 CUBIC INCH CAPACITY
TP594
—
8 – 1/ 2"
TP596
—
6 – 3/ 4"
TP598
5 – 1/ 2"
"S", SET 1/ 2"
3 – 1/ 2"
3 – 1/ 2"
3 – 1/ 2"
Steel Boxes
TP588, TP647
Covers
TP608
TP610
TP612
TP613
Cat. #
Description
TP608*
TP610*
TP612*
TP613*
TP614*
TP616*
TP618*
Blank
For 20 and 30 AMP, Twist Lock, 119/ 32" Diameter
Single Receptacle, 113/ 32" Diameter
For GFCI Device
1/ 2" KO
Duplex Receptacle
One Toggle Switch
TP614
TP616
TP618
Std. Unit Pkg.
Wt. Lbs. Per 100
100
100
100
100
100
100
100
10
9
9
7
10
8
10
*CSA Certified
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
47
Steel Specialty Boxes
Steel Boxes
4" OCTAGON CONCRETE BOXES AND HUNG CEILING BOXES*
TP620, TP622, TP628
TP635, TP636, TP644
TP623, TP624
(bars not included)
TP348
KNOCKOUTS
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Capacity
Cu. In.
& 3/ 4" Single Row
& 3/ 4" Single Row
1/ 2" & 3/ 4" Single Row
1/ 2" Double Row
1/ 2" & 3/ 4" Double Row
1/ 2" & 3/ 4" Double Row
25
25
20
20
20
20
60
72
85
93
93
113
23.0
29.0
35.0
43.0
43.0
47.0
HUNG CEILING BOXES (WITH TP650 COVER, ORDER BARS SEPARATELY)
1/ 2" Double Row
TP623
31/ 2"
1/ 2" & 3/ 4" Double Row
TP624
31/ 2"
20
20
93
93
43.0
43.0
BARS FOR HUNG CEILING BOXES
TP348
30" bars (Bars Sold Separately)
40
60
–
Cat. #
Depth
TP620
TP622
TP628
TP635
TP636
TP644
2"
21/ 2"
3"
31/ 2"
31/ 2"
4"
1/ 2"
1/ 2"
*Weight limit for 4" octagon concrete boxes is 50lbs. Not suitable for fans.
CONCRETE BOX PLATES
TP648
TP649
Cat. #
Description
TP648
TP649
TP650
TP652
No Stud 3 – 1/ 2" & 2 – 3/ 4" KOs
Flat, Blank
3/ 8" Stud 2 – 1/ 2" & 2 – 3/ 4" KOs
Single Receptacle
48
US: 1-866-764-5454
CAN: 1-800-265-0502
TP650
TP652
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
50
50
28
28
33
24
Copyright© 2007 Cooper Crouse-Hinds
Steel Masonry Boxes
MASONRY BOXES
21/2" DEEP × 33/4" HIGH
1/ 2" AND 3/ 4" CONCENTRIC KOs
Steel Boxes
TP682
KNOCKOUTS
Cat. #
Gang
Width
Each Side
Each End
Bottom
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Capacity
Cu. In.
TP682
TP683
TP684
TP685
TP686
TP687
1
2
3
4
5
6
115/ 16"
33/ 4"
59/ 16"
73/ 8"
93/ 16"
11"
2
2
2
2
2
2
1
2
3
4
5
6
2
4
6
8
10
12
20
10
5
5
5
1
70
103
129
165
189
230
15.5
31.0
46.5
62.0
77.5
93.0
MASONRY BOXES
31/2" DEEP × 33/4" HIGH
1/ 2" AND 3/ 4" CONCENTRIC KOs
TP690
KNOCKOUTS
Cat. #
Gang
Width
Each Side
Each End
Bottom
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Capacity
Cu. In.
TP690
TP691
TP692
TP693
TP694
TP695
1
2
3
4
5
6
115/ 16"
33/ 4"
59/ 16"
73/ 8"
93/ 16"
11"
2
2
2
2
2
2
2
4
6
8
10
12
2
4
6
8
10
12
20
10
10
5
5
1
84
120
155
207
235
287
22.0
44.0
66.5
88.0
110.0
132.0
MASONRY BOX PARTITIONS
Cat. #
Description
TP820
TP821
Nonmetallic Partition for 21/ 2" Deep Masonry Boxes
Nonmetallic Partition for 31/ 2" Deep Masonry Boxes
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Std. Unit
Pkg.
Wt. Lbs.
Per 100
25
25
3
4
49
Steel Gang Boxes
GANG BOXES
Steel Boxes
15/8" DEEP × 41/2" HIGH
1/ 2" & 3/ 4" KOs
TP630
TP640
KNOCKOUTS
Cat. #
Gang
Cubic
Inches
TP629
TP630
TP631
TP640
TP641
2
3
4
5
6
45
58
70
85
95
Width
Each Side
613/ 16"
85/ 8"
107/ 16"
121/ 4"
141/ 16"
2 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 2 – 3/ 4"
3 – 1/ 2", 3 – 3/ 4"
4 – 1/ 2", 3 – 3/ 4"
4 – 1/ 2" 4 – 3/ 4"
Each End
1
1
1
1
1
–
–
–
–
–
1/ 2",
1
1
1/ 2", 1
1/ 2", 1
1/ 2", 1
1/ 2",
–
–
–
–
–
Bottom
3/ 4"
3
6
6
6
6
3/ 4"
3/ 4"
3/ 4"
3/ 4"
–
–
–
–
–
1/ 2",
2
4
1/ 2", 4
1/ 2", 4
1/ 2", 4
–
–
–
–
–
1/ 2",
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
Std. Unit
Pkg.
Wt. Lbs.
Per 100
5
5
5
1
1
45
58
70
85
95
Std. Unit
Pkg.
Wt. Lbs.
Per 100
10
10
5
5
5
147
183
216
263
282
GANG BOXES
21/2" DEEP × 41/2" HIGH
3/ 4" & 1" KOs
TP871
TP873
KNOCKOUTS
Cat. #
Gang
Cubic
Inches
TP870
TP871
TP872
TP873
TP874
2
3
4
5
6
71
90
110
132
150
Width
613/ 16"
85/ 8"
107/ 16"
121/ 4"
141/ 16"
Each Side
2
4
2
3
3
–
–
–
–
–
3/ 4",
1
1
3/ 4", 2
3/ 4", 2
3/ 4", 3
3/ 4",
–
–
–
–
–
1"
1"
1"
1"
1"
Each End
1
1
1
1
1
–
–
–
–
–
3/ 4",
1
1
3/ 4", 1
3/ 4", 1
3/ 4", 1
3/ 4",
–
–
–
–
–
Bottom
1"
1"
1"
1"
1"
3
6
6
6
6
–
–
–
–
–
1/ 2",
2
4
1/ 2", 4
1/ 2", 4
1/ 2", 4
1/ 2",
–
–
–
–
–
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
GANG BOX PARTITIONS
TP876
Cat. #
Description
TP876
TP877
For 15/ 8" Deep Box
For 21/ 2" Deep Box
50
TP877
US: 1-866-764-5454
CAN: 1-800-265-0502
Std. Unit
Pkg.
Wt. Lbs.
Per 100
25
50
19
24
Copyright© 2007 Cooper Crouse-Hinds
Steel Gang Box Covers
GANG BOX COVERS
RAISED 13/16" FOR PLASTER
Steel Boxes
TP653
TP667
Cat. #
Gang
Length
Std. Unit Pkg.
Wt. Lbs. Per 100
Capacity Cu. In.
TP657
TP653
TP655
TP661
TP667
2
3
4
5
6
7"
813/ 16"
105/ 8"
127/ 16"
141/ 4"
5
5
5
5
5
53
60
66
75
85
8.5
13.5
18.3
23.0
28.3
GANG BOX COVERS, FLAT, BLANK
TP803
TP806
Cat. #
Gang
Length
Std. Unit Pkg.
Wt. Lbs. Per 100
TP802
TP803
TP804
TP805
TP806
2
3
4
5
6
7"
813/ 16"
105/ 8"
127/ 16"
141/ 4"
5
5
5
1
1
66
85
94
122
132
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
51
PVC Switch Boxes
Applications:
Cooper Crouse-Hinds nonmetallic switch and outlet boxes are used:
• In branch circuit wiring as a splice point
• To mount wiring devices such as switches and receptacles
• To provide mechanical protection for wiring systems and electrical
devices
PVC Boxes
Features:
• Available for use with wood or metal studs to meet any construction
preference
• Quick entry feature on all nonmetallic boxes offers labor savings –
no need to break out knockouts – simply push the nonmetallic cable
into the box. No tools are required. No need to remove knockouts.
• Unique configuration of this quick entry feature on single gang
boxes provides a self-feeding feature that eliminates the need to
reach inside the box to pull the wire out.
• Integral labor saving clamping feature on two, three & four gang
boxes. The multiple gang box unique entry also serves as a clamp,
eliminating the need to mechanically secure the cable inside the
box. There are no separate clamps or screws to install or tighten.
Each entry into the multiple gang boxes has the quick entry feature
allowing the installer to simply push the cable into the box without
the need for tools or removal of knock-outs, so the cable can be
inserted where it is required.
Standard Materials:
• PVC-Polyvinyl Chloride compound
Certifications and Compliances:
• UL Listed File No. E102328
• Classified for use in fire rated (2 HR) wall or ceiling. Fire Rating No.
R9933.
SWITCH BOXES – ANGLED NAILS
TP1600
Cat. #
TP1600
TP1800
TP2000
TP2300
TP1800
TP2000
Bracket
or Nails
Capacity
Cu. In.
H
W
Nails
Nails
Nails
Nails
16.0
18.0
20.3
22.5
33/ 4"
33/ 4"
33/ 4"
33/ 4"
21/ 4"
21/ 4"
21/ 4"
21/ 4"
TP2300
D
Std. Unit
Pkg.
Wt. Lbs.
Per 100
21/ 2"
23/ 4"
33/ 16"
37/ 16"
100
100
100
50
21
23
25
27
For Labor Savings Speed-Mount™ Switchboxes, see page 56
52
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
PVC Switch Boxes
SWITCH BOXES – INTEGRAL CLAMPS
TP2030
(For Wood or Metal Studs)
Bracket
or Nails
Capacity
Cu. In.
H
W
D
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Swing Clips & Integral Clamps
Side Bracket (5/ 8" offset)
Face Bracket (1/ 2" offset)
16.0
20.3
20.3
35/ 8"
311/ 16"
311/ 16"
25/ 16"
21/ 4"
21/ 4"
23/ 4"
33/ 16"
33/ 16"
50
50
50
20
24
24
Cat. #
TP1690
TP2020
TP2030
TP2020
(For Wood or Metal Studs)
PVC Boxes
TP1690
(Old Work)
3" DEEP SWITCH BOXES – TWO GANG
TP3490
(Old Work)
Cat. #
TP3490
TP3600
TP3630*
TP3635*
TP3600
TP3630
TP3635
Bracket
or Nails
Capacity
Cu. In.
H
W
D
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Swing Clips
Nails
Brackets
Brackets & Nails
34.0
36.0
36.0
36.0
39/ 16"
33/ 4"
33/ 4"
33/ 4"
4"
4"
4"
4"
33/ 16"
3"
3"
3"
25
25
25
25
29
37
37
39
*Face Bracket on PVC Boxes are offset 1/ 2" unless stated otherwise
211/16" DEEP SWITCH BOXES – THREE GANG
TP4600
Cat. #
TP4600
TP4630*
TP4635*
TP4630
TP4635
Bracket
or Nails
Capacity
Cu. In.
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Nails
Brackets
Brackets & Nails
46.0
46.0
46.0
20
20
20
45
43
46
For Labor Savings Speed-Mount™ Switchboxes, see page 56
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
53
PVC Switch Boxes
211/16" DEEP SWITCH BOXES – FOUR GANG
PVC Boxes
TP6100
TP6135
Bracket
or Nails
Capacity
Cu. In.
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Nails
Nails & Brackets
Brackets & Bar Support
61.0
61.0
61.0
4
4
4
65
66
87
Cat. #
TP6100†
TP6135*†
TP6180*†
TP6180
*Face Bracket on PVC Boxes are offset 1/ 2" unless otherwise stated
†Not 2-Hour Fire Rated
LOW VOLTAGE PARTITION – TWO, THREE OR FOUR GANG PVC
TP1000
Cat. #
TP1000
Bracket
or Nails
Capacity
Cu. In.
Std. Unit
Pkg.
Master
Pkg.
Wt. Lbs.
Per 100
—
—
20
120
3
4" SQUARE WITH INTEGRAL CLAMPS – 20.3 CUBIC INCH CAPACITY
15/8" DEEP
TP1900
Cat. #
TP1900
TP1930
54
TP1930
Bracket
Capacity
Cu. In.
Std. Unit
Pkg.
Wt. Lbs.
Per 100
—
"F" Bracket
20.3
20.3
50
50
26
40
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
PVC Switch Boxes
4" SQUARE PVC DEVICE COVERS
TP1009
TP1009
TP1010
TP1020
TP1013
TP1014
TP1023
TP1024
TP1020
TP1013, TP1014
TP1023, TP1024
Raised
Capacity
Cu. In.
Std. Unit
Pkg.
Wt. Lbs.
Per 100
—
—
—
1/ 2"
5/ 8"
1/ 2"
5/ 8"
—
—
—
3.8
4.8
5.8
7.0
50
50
50
50
50
50
50
9
6
4
8
8
8
8
PVC Boxes
Cat. #
TP1010
ROUND BLANK COVER – PVC
43/4" DIA.
(FOR 31/2" AND 4" ROUND CEILING BOXES)
TP1040, TP1045
Cat. #
Color
Screws
Std. Unit
Pkg.
Wt. Lbs.
Per 100
TP1040
TP1045*
Gray
White
—
White
100
100
10
12
*TP1045 includes two white-headed wood and two #8-32" machine screws.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
55
Nonmetallic Ceiling Boxes
Nonmetallic Switchboxes
New! Speed-Mount™ Switchboxes
Features:
The labor saving Speed-Mount device installation feature is simple
and easy to use. The device is attached by simply pressing the device
mounting screw into the device hole in the box and turning the screw
to lock it in place. The spring steel clip locks the screw securely in
place. To remove the device, simply unscrew the screw in the
traditional manner.
• Available for use with wood or metal stud to meet any construction
preference
• Quick entry feature on all nonmetallic boxes offers labor savings –
no need to break out knockouts – simply push the nonmetallic cable
into the box. No tools are required. No need to remove knockouts.
• Unique configuration of this quick entry feature on single gang
boxes provides a self-feeding feature that eliminates the need to
reach inside the box to pull the wire out.
• Integral labor saving clamping feature on two, three & four gang
boxes. The multiple gang box unique quick entry also serves as a
clamp, eliminating the need to mechanically secure the cable inside
the box. There are no separate clamps or screws to install or
tighten. Each entry into the multiple gang boxes has the quick entry
feature allowing the installer to simply push the cable into the box
without the need for tools or removal of knockouts, so the cable can
be inserted where it is required.
• Speed-Mount Switchboxes offer simple, labor saving press
installation of devices. The device is attached by simply pressing the
device mounting screw into the device hole and turning the screw to
lock it in place. The spring steel clip locks the screw securely in
place.
Our new Speed-Mount™ SWITCHBOXES provide significant labor savings
through our quick cable entry feature and express device installation feature.
Applications:
Cooper Crouse-Hinds nonmetallic Speed-Mount Switchboxes are
used:
• In branch circuit wiring as a splice point
• To mount wiring devices such as switches, receptacles, GFCI’s,
dimmers etc.
• To provide mechanical protection for wiring systems and electrical
devices
Cat. #
TP1802
TP1832
TP2002
TP2302
TP2332
TP3602
TP3632
TP4602
TP4632
TP6102
TP6132
Standard Materials:
• PVC – Polyvinyl Chloride compound
Certifications and Compliances:
• UL Listed
• Classified for use in fire rated (2 HR) wall or ceiling
Capacity Cu. In.
Description
Bracket or Nails
Std. Unit Qty.
18.0
18.0
20.0
22.5
22.5
36.0
36.0
54.0
54.0
72.0
72.0
single gang
single gang
single gang
single gang
single gang
2 gang box
2 gang box
3 gang box
3 gang box
4 gang box
4 gang box
nails
bracket
nails
nails
bracket
nails
bracket
nails
bracket
nails
bracket
100
100
100
50
50
25
25
20
20
4
4
box
box
box
box
box
Far Side Support – For use with Speed-Mount™ Switchboxes
Applications:
How to use:
• Far Side Support is designed for use with Speed-Mount™
switchboxes used with either wood or metal studs to provide a
quick, easy economical way for far side support.
• The multi-gang Speed-Mount™ boxes have a molded-in-hole in the
back for attaching the TPFSS. The molded-in-hole has two flats as
you look at the back of the box. There are also two flats on the
TPFSS. To install, simply align the flats and push the TPFSS into
the hole. Turn 1/ 4 turn to lock into place.
• The TPFSS is designed for use with steel studs with a depth of
35/ 8". For use with 2 × 4 wood studs, simply break off the tip at the
notch of the TPFSS using a pair of pliers.
Cat. #
Capacity Cu. In.
TPFSS
—
56
Description
—
US: 1-866-764-5454
CAN: 1-800-265-0502
Bracket or Nails
Std. Unit Qty.
—
100
Copyright© 2007 Cooper Crouse-Hinds
Ceiling Boxes
31/2" NONMETALLIC CEILING BOXES
27/8" DEEP
Weight limit is 50 lbs for fixture except where indicated.
Cat. #
TP16200†
TP16201†
TP16310*
TP16311*
TP16307*‡
TP16308*‡
TP16317*
TP16318*
TP16310
TP16311
TP16307
TP16308
Nonmetallic Ceiling Boxes
TP16200,
(TP16201 – 21/8" Deep)
Old Work
TP16317
TP16318
Clamps
Ground
Plate
Bracket/Bar Hgr.
Capacity
Cu. In.
No. of Clamp
Openings
Std. Unit
Pkg.
Wt. Lbs.
Per 100
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—
Yes
—
Yes
—
Yes
—
Yes
Snap
Snap
Nails
Nails
14"–22-1/2"
14"–22-1/2"
"B"
"B"
16.0
16.0
19.3
19.3
19.3
19.3
19.3
19.3
4
4
4
4
4
4
4
4
50
50
50
50
25
25
50
50
27
29
18
20
57
59
26
20
*Nail Bracket is set 19/ 16" back from the face of the box.
† Weight limit 15lbs for ceiling mounted fixtures and 6lbs for wall mounted fixtures.
‡ Weight limit 15lbs at 24" stud spacing, 35lbs at 16" stud spacing.
LAMPHOLDER
TP16098
TP16099
Standard Materials:
• Plastic molded of heat and impact resistant material that prevents
discoloring and reduces breakage
Cat. #
Description
TP16098
TP16099
Lampholder, Pull Chain
Lampholder, Keyless, feed thru
US: 1-866-764-5454
CAN: 1-800-265-0502
Std. Unit Pkg.
Wt. Lbs. Per 100
50
50
29
23
Copyright© 2007 Cooper Crouse-Hinds
57
Ceiling Boxes
4" NONMETALLIC CEILING BOXES
Nonmetallic Ceiling Boxes
Weight limit is 50 lbs for fixture except where indicated
TP16111, TP16110
TP16012, TP16112
TP16007, TP16107
TP16002
TP16022, TP16122
Clamps
Ground
Plate
Bracket/Bar Hgr.
Capacity
Cu. In.
No. of Cable
Pry-outs
Std. Unit
Pkg.
Wt. Lbs.
Per 100
11/2" DEEP
TP16002
TP16003
TP16012
TP16013
TP16007
TP16008
TP16022*
TP16023*
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—
Yes
—
Yes
—
Yes
—
Yes
—
—
"V"
"V"
"B"
"B"
14"–22-1/2"
14"–22-1/2"
14.8
14.8
14.8
14.8
14.8
14.8
14.8
14.8
4
4
4
4
4
4
4
4
50
50
50
50
50
50
25
25
12
14
24
26
26
28
56
58
21/4" DEEP
TP16111
TP16110
TP16112
TP16113
TP16107
TP16108
TP16122*
TP16123*
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
—
Yes
—
Yes
—
Yes
—
Yes
Nails
Nails
"V"
"V"
"B"
"B"
14"–22-1/2"
14"–22-1/2"
22.5
22.5
20.8
20.8
20.8
20.8
20.8
20.8
4
4
4
4
4
4
4
4
50
50
50
50
50
50
20
20
19
21
27
29
28
30
59
61
Cat. #
*Weight limit 15 lbs at 24" stud spacing, 35 lbs at 16" stud spacing.
4" NONMETALLIC CEILING FAN BOXES
With clamps for nonmetallic cable.
All mounting hardware supplied, suitable for support of fans weighing up to 35 lbs.
TP16511
Cat. #
TP16511
58
Diameter
Mounting
Method
Capacity
Cu. In.
No. of Clamp
Openings
Std. Unit
Pkg.
Wt. Lbs.
Per 100
4"
Nails only
20.8
6
25
21
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Weatherproof Outlet Boxes
Cooper Crouse-Hinds weatherproof products are manufactured in
compliance with U.L. requirements for weatherproof boxes and covers
and meet U.L. Standard #514A. Cooper Crouse-Hinds lighting
products comply with the U.L. requirements of standard UL 1598 and
are suitable for wet locations.
Cooper Crouse-Hinds weatherproof boxes and covers are individually
shrink-wrapped. Cooper Crouse-Hinds weatherproof cast aluminum
boxes are lugged except where noted and are provided with plugs.
The self-closing weatherproof covers are zinc die-cast. The
weatherproof lampholders have porcelain sockets and are rated up to
150 watts and have 81/ 2" wire leads.
Cooper Crouse-Hinds weatherproof products are rust and corrosion
resistant made of rugged die-cast construction. Cooper Crouse-Hinds
weatherproof products are provided with necessary gaskets, plugs
and screws, making installation trouble free.
Vaporite fixtures are die-cast aluminum and the screw-on guards are
die-cast zinc, with Allen-Head set screws for locking in place. The
fixtures also have a neoprene gasket and porcelain clip-in socket.
All products are powder coat painted and various colors are available.
SINGLE GANG WEATHERPROOF OUTLET BOXES – 18.0 CUBIC INCH CAPACITY
– 2" DEEP
Weatherproof
CAST ALUMINUM – UL LISTED FOR WET LOCATIONS
TP7010 – TP7018
TP7026, TP7034
TP7042, TP7050
Cat. #
Description
Outlet
Holes
TP7010
TP7011
TP7012
TP7018
TP7026
TP7034
TP7042
TP7050
TP7058
TP7066
TP7071
With Lugs
With Lugs
With Lugs
With Lugs
With Lugs
With Lugs
With Lugs
With Lugs
Side Entry, With Lugs
Side Entry, With Lugs
Horiz. Mounting, With Lugs
3
3
3
3
4
4
5
5
5
5
4
–
–
–
–
–
–
–
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
TP7058, TP7066
TP7071
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
Gray
White
Bronze
Gray
Gray
Gray
Gray
Gray
Gray
Gray
Gray
50
50
50
50
50
50
50
50
50
50
50
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
58.3
SINGLE GANG WEATHERPROOF OUTLET BOXES – 24.0 CUBIC INCH CAPACITY
– 25/8" DEEP
CAST ALUMINUM – UL LISTED FOR WET LOCATIONS
TP7074, TP7078, TP7082
Cat. #
Description
Outlet
Holes
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
TP7074
TP7078
TP7082
With Lugs
With Lugs
With Lugs
3 – 1/ 2"
3 – 3/ 4"
3 – 1"
Gray
Gray
Gray
25
25
25
80
80
80
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
59
Weatherproof Outlet Boxes
TWO GANG WEATHERPROOF OUTLET BOXES – 30.5 CUBIC INCH CAPACITY
2" DEEP, ALL TWO GANG BOXES HAVE 2 MOUNTING LUGS AS STANDARD
CAST ALUMINUM – UL LISTED FOR WET LOCATIONS
Weatherproof
TP7086 – TP7090
TP7094, TP7098
Cat. #
Description
TP7086
TP7087
TP7088
TP7090
TP7094
TP7098
TP7102
TP7106
TP7110
TP7114
TP7118
TP7122
3
3
3
3
4
4
5
5
7
7
5
5
–
–
–
–
–
–
–
–
–
–
–
–
1/ 2"
1/ 2"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
Holes
Holes
Holes
Holes
Holes
Holes
Holes
Holes
Holes
Holes
Holes
Holes
TP7102, TP7106
TP7110, TP7114
TP7118, TP7122
Std. Unit
Carton
Color
Wt. Lbs.
Per 100
10
10
10
10
10
10
10
10
10
10
10
10
Gray
White
Bronze
Gray
Gray
Gray
Gray
Gray
Gray
Gray
Gray
Gray
83.3
83.3
83.3
83.3
83.3
83.3
83.3
83.3
83.3
83.3
83.3
83.3
TWO AND THREE GANG DEEP WEATHERPROOF OUTLET BOXES
25/8" DEEP, ALL BOXES ARE STANDARD WITH MOUNTING LUGS
CAST ALUMINUM – UL LISTED FOR WET LOCATIONS
TP7126, TP7130, TP7134
TP7137, TP7138, TP7142
TP7143, TP7144
Std. Unit
Carton
Capacity
Cu. In.
Wt. Lbs.
Per 100
TWO GANG DEEP WEATHERPROOF OUTLET BOXES
TP7126
Gray
5 – 1/ 2" Holes
Gray
TP7130
5 – 3/ 4" Holes
TP7134
5 – 1" Holes
Gray
Gray
TP7137
7 – 1/ 2" Holes
TP7138
Gray
7 – 3/ 4" Holes
TP7142
7 – 1" Holes
Gray
6
6
6
6
6
6
37
37
37
37
37
37
140
140
140
140
140
140
THREE GANG DEEP WEATHERPROOF OUTLET BOXES
TP7143
Gray
7 – 3/ 4" Holes
TP7144
7 – 1" Holes
Gray
5
5
59
59
159
159
Cat. #
60
Description
Color
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Weatherproof Outlet Boxes
ONE & TWO GANG WEATHERPROOF EXTENSIONS
1" DEEP, DIE-CAST ALUMINUM EXTENSION RING
GASKET AND MOUNTING SCREWS INCLUDED WITH COVER
UL LISTED FOR WET LOCATIONS
TP7120
TP7123
Description
Color
TP7120
TP7123
Single Gang
Two Gang
Gray
Gray
25
10
Capacity
Cu. In.
Wt. Lbs.
Per 100
9
10
27.2
27.2
Weatherproof
Cat. #
Std. Unit
Carton
EXTENSION ADAPTER
DIE-CAST ALUMINUM, UL LISTED FOR WET LOCATIONS 3 CLOSURE PLUGS,
MOUNTING SCREW AND GASKET INCLUDED WITH COVER
Cat. #
Description
Color
Std. Unit
Carton
Capacity
Cu. In.
Wt. Lbs.
Per 100
TP7173
TP7174
4 – 1/ 2" Holes
4 – 3/ 4" Holes
Gray
Gray
25
25
13.0
13.0
23.6
27.8
4" ROUND WEATHERPROOF OUTLET BOXES – 15.5 CUBIC INCH CAPACITY
11/2" DEEP, DIE-CAST ALUMINUM, UL LISTED FOR WET LOCATIONS
4 CLOSURE PLUGS AND GROUND SCREW INCLUDED WITH BOX
GASKET AND 2 MOUNTING SCREWS INCLUDED WITH COVER
Cat. #
TP7146
TP7148
TP7149
TP7150
TP7158
Side
Holes
4
4
4
4
–
–
–
–
Back
Hole
Std. Unit
Carton
Color
Wt. Lbs.
Per 100
1/ 2"
1/ 2"
1/ 2"
1/ 2"
25
25
25
25
50
Gray
White
Bronze
Gray
Gray
79.2
79.2
79.2
79.2
20.8
24
24
Gray
Gray
100
100
Gray
58.3
1/ 2"
1/ 2"
3/ 4"
3/ 4"
Blank Cover Plate
WITH BLANK PLATE
TP7147
4 – 1/ 2"
TP7151
4 – 3/ 4"
1/ 2"
3/ 4"
2" DEEP ROUND WEATHERPROOF OUTLET BOX EXTENSION (18.3 CUBIC INCH CAPACITY)
TP7152
—
25
4 – 1/ 2"
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
61
Weatherproof Outlet Covers
WEATHERPROOF COVERS
Weatherproof
ONE & TWO GANG, SELF-CLOSING COVERS WITH GASKETS
UL LISTED, ZINC DIE-CAST
TP7199
TP7202
TP7206 – TP7209
TP7214
TP7220
TP7224
TP7228
TP7232
Cat. #
Description
TP7199
TP7202
TP7206
TP7207
TP7208
TP7209
TP7214
TP7218
TP7220
One Gang Vertical Duplex Cover
One Gang – For Single Receptacle or Switch – 1.52" Dia. Opening
One Gang – For Duplex Receptacle or Combination Switch
One Gang – For Duplex Receptacle or Combination Switch
One Gang – For Duplex Receptacle or Combination Switch
One Gang – For Duplex Receptacle or Combination Switch
One Gang Vertical – For Single Receptacle or Switch 1.62" Dia. Opening
One Gang – For 20, 30 and 50 A Receptacles (2.125" Dia.)
Two Gang – For Two Single Receptacles and/or Switches
Two Gang – For One Single Receptacle or Switch and One Duplex Receptacle, Switch or
Combination Device
Two Gang – For Two Duplex Receptacles, Switches or Combination Device
One Gang Stay Open – For Duplex Receptacles, Switches or Combination Devices, Non UL
Listed
One Gang Stay Open – For Duplex Receptacles, Switches or Combination Devices, Non UL
Listed
TP7224
TP7228
TP7232
TP7233
TP7218
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
Gray
Gray
Natural
Gray
White
Bronze
Gray
Gray
Gray
50
25
50
50
50
50
25
25
10
61.1
42.0
38.0
38.0
38.0
38.0
61.1
55.6
66.7
Gray
10
62.0
Gray
10
61.1
Natural
50
38.0
Gray
50
38.0
CLOSURE PLUGS – ZINC DIE-CAST*
Cat. #
Description
TP7940
TP7942
TP7944
1/ 2"
1/ 2"
3/ 4"
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
Gray
Bronze
Gray
100
100
50
1.5
1.5
2.1
*CSA certified
62
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Weatherproof Outlet Covers
WEATHERPROOF COVERS
ONE & TWO GANG SELF-CLOSING GFI COVERS WITH GASKETS
UL LISTED, ZINC DIE-CAST
TP7236 – TP7238
TP7240 – TP7242
TP7244
TP7248
TP7252
Description
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
TP7236
TP7237
TP7238
TP7240
TP7241
TP7242
TP7244
One Gang – For Horizontal GFI Devices
One Gang – For Horizontal GFI Devices
One Gang – For Horizontal GFI Devices
One Gang – For Vertical GFI Devices
One Gang – For Vertical GFI Devices
One Gang – For Vertical GFI Devices
Two Gang – For Vertical GFI Devices and One Single Switch or Receptacle
Two Gang – For One Vertical GFI Device and One Duplex Receptacle, Switch or Combination
Device
Two Gang – For Two GFI Devices
Gray
White
Bronze
Gray
White
Bronze
Gray
25
25
25
25
25
25
10
42
42
42
54
54
54
61.1
Gray
10
61.1
Gray
10
55.6
TP7248
TP7252
Weatherproof
Cat. #
WEATHERPROOF COVERS
FOR ONE & TWO GANG BOXES
"CONSTANT USE" DUPLEX/GFI COVER
UL & CSA LISTED, POLYCARBONATE
TP7490
TP7495
31/8" Deep
21/4" Deep
Cat. #
Description
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
TP7490
TP7495
One Gang, Vertical Mtg. For Duplex or GFI Device (Inserts Included)
One or Two Gang, Vertical or Horizontal Mtg. For One Duplex or GFI Device (Inserts Included)
Clear
Clear
6
6
41.7
75
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
63
Weatherproof Outlet Covers
WEATHERPROOF COVERS
ONE & TWO GANG TOGGLE SWITCH COVERS
WITH GASKETS STAMPED ALUMINUM
UL LISTED
Weatherproof
TP7280
TP7268
5/ 8" Thick
Cat. #
Description
TP7260
TP7268
TP7272
TP7276
TP7280
One Gang With 15A 125V Single Pole Switch
Two Gang
Two Gang With 2 – 15A 125V Single Pole Switch
Two Gang With 2 – 15A 125V 3-Way Switch
One Gang Extended Switch Cover – (for use with Standard Switch)
Std. Unit
Carton
Wt. Lbs.
Per 100
50
10
10
10
50
27.8
16.7
33.3
33.3
34.1
ALUMINUM BLANK BOX WEATHERPROOF COVERS
WITH GASKETS
UL LISTED FOR WET LOCATIONS
TP7292 – TP7294
TP7296 – TP7298
Cat. #
Description
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
TP7292
TP7293
TP7294
TP7296
TP7297
TP7298
One Gang
One Gang
One Gang
Two Gang
Two Gang
Two Gang
Gray
White
Bronze
Gray
White
Bronze
100
100
100
50
50
50
8.3
8.3
8.3
12.5
12.5
12.5
64
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Weatherproof Outlet Covers
ROUND AND RECTANGULAR WEATHERPROOF COVERS
WITH GASKETS, ZINC DIE-CAST, UL LISTED FOR WET LOCATIONS
TP7300 – 7302
TP7308 – 7310
Description
TP7300
TP7301
TP7302
TP7308*
TP7309*
TP7310*
TP7312
TP7313
TP7314
TP7316
TP7317
TP7318
TP7320
TP7321
TP7322
TP7158
TP7159
TP7160
41/ 2" Round
41/ 2" Round
41/ 2" Round
41/ 2" Round
41/ 2" Round
41/ 2" Round
Rectangular
Rectangular
Rectangular
Rectangular
Rectangular
Rectangular
Rectangular
Rectangular
Rectangular
Blank Round
Blank Round
Blank Round
No. of Outlet
Holes
1
1
1
3
3
3
1
1
1
2
2
2
3
3
3
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
– 1/ 2"
—
—
—
TP7316 – 7318
TP7320 – 7322
TP7158 – 7160
Color
Std. Unit
Carton
Wt. Lbs.
Per 100
Gray
White
Bronze
Gray
White
Bronze
Gray
White
Bronze
Gray
White
Bronze
Gray
White
Bronze
Gray
White
Bronze
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
50
50
50
20.8
20.8
20.8
33.3
33.3
33.3
33.3
33.3
33.3
33.3
33.3
33.3
33.3
33.3
33.3
20.8
20.8
20.8
Weatherproof
Cat. #
TP7312 – 7314
*Comes with closure plug
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
65
Weatherproof Lampholders
WEATHERPROOF LAMPHOLDERS AND ACCESSORIES
ZINC DIE-CAST CONSTRUCTION, UP TO 150 WATTS, WITH LAMP GASKET, UL LISTED
Weatherproof
TP7162 – TP7165
TP7166
Cat. #
Description
TP7162
TP7163
TP7164
TP7165
TP7166
TP7170
TP7176
Universal Par Lampholder
Universal Par Lampholder
Universal Par Lampholder
Universal Par Lampholder
Universal Par Lampholder With External Gasket
External Gasket Only
Clamp-On Guard
TP7176
Color
Std. Unit Carton
Wt. Lbs. Per 100
Natural
Gray
White
Bronze
Gray
—
—
36
36
36
36
36
100
24
47.2
47.2
47.2
47.2
50
3
50
WEATHERPROOF LAMPHOLDERS AND ACCESSORIES
ZINC DIE-CAST CONSTRUCTION, UP TO 150 WATTS, WITH LAMP GASKET, UL LISTED
TP7178
TP7186
TP7188
(Aluminum)
Cat. #
Description
Color
Std. Unit Carton
Wt. Lbs. Per 100
TP7178
TP7186
TP7188
Par Lampholder With Reflector
Portable Par Lampholder With 6' Cord
21/ 2" Outside Diameter Pole Fitter with 1/ 2" Male Thread
Gray
Gray
Gray
6
12
24
166.7
100
50
WEATHERPROOF LAMPHOLDER COMBINATIONS
ZINC DIE-CAST CONSTRUCTION, WITH GASKETS, UL LISTED
TP7330 – TP7332
Cat. #
Description
Color
Std. Unit Carton
Wt. Lbs. Per 100
TP7330
TP7331
TP7332
2 Par Lampholders and 3-Hole Round Cover
2 Par Lampholders and 3-Hole Round Cover
2 Par Lampholders and 3-Hole Round Cover
Gray
White
Bronze
10
10
10
137.5
137.5
137.5
66
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Weatherproof Outdoor HID Luminaires
Luminarea™ Series Area Luminaires
Cooper Crouse-Hinds Luminarea Luminaires are ideally suited for
general and security lighting indoors or outdoors. Area luminaires are
available in 2 sizes in 70 to 175 watt metal halide and 70 to 150 watt
high pressure sodium. The bronze epoxy powder coated housing is
designed for an extended, trouble-free life. The housing is gasketed
for raintight (NEMA 3R) locations. The prismatic polycarbonate lens is
vandal resistant for even light distribution. Typical applications include
parking garages, storage areas, stairwells, corridors and lobbies.
Key Features and Benefits:
Materials and Finishes:
•
•
•
•
•
•
•
•
•
•
•
Housing – Die Cast Aluminum
Lens – Polycarbonate
Gasket – Silicone
Hardware – Stainless Steel
Weatherproof
Durable die cast aluminum housing for long product life.
Architectural bronze powder paint finish for corrosive enviroments.
Stainless steel hardware.
Internal white reflector for maximum light output.
Vandal resistant polycarbonate lens.
Side and top plugged threaded entries for easy field wiring.
High power factor ballast in multi-tap (120, 208, 240, 277 volt) or tritap (120, 277, 347 volt) configurations.
• Two housing sizes insure maximum utilization of space.
• Available in 70 to 175 watt metal halide or high pressure sodium
versions.
Ratings:
• 70 to 175 watt metal halide and high pressure sodium
• Multi-tap (120, 208, 240, 277 volts) or Tri-tap (120, 277, 347 volts)
• 480V
For accessories & dimensions, see pages 67–71
Certifications and Compliances:
• UL1598
• UL and cUL listed
• NEMA 3R raintight
Cat. #
Description
High Pressure Sodium
70
120/208/240/277
70
120/277/347
100
120/208/240/277
100
120/277/347
150
120/208/240/277
150
120/277/347
Watts
Voltage
Lamp Base
Ballast
WLPG70HPS/MT
WLPG70HPS/TT
WLPG100HPS/MT
WLPG100HPS/TT
WLPG150HPS/MT
WLPG150HPS/TT
8" × 8" Housing
8" × 8" Housing
12" × 12" Housing
12" × 12" Housing
12" × 12" Housing
12" × 12" Housing
Medium
Medium
Medium
Medium
Medium
Medium
HPF
HPF
HPF
HPF
HPF
HPF
Metal Halide
70
120/208/240/277
70
120/277/347
100
120/208/240/277
100
120/277/347
175
120/208/240/277
175
120/277/347
WLPG70MH/MT
WLPG70MH/TT
WLPG100MH/MT
WLPG100MH/TT
WLPG175MH/MT
WLPG175MH/TT
8" × 8" Housing
8" × 8" Housing
12" × 12" Housing
12" × 12" Housing
12" × 12" Housing
12" × 12" Housing
Medium
Medium
Medium
Medium
Medium
Medium
HPF
HPF
HPF
HPF
HPF
CWA
Lamp not included.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
67
Weatherproof Outdoor HID Luminaires
Luminarea™ Series Area Luminaires
Weatherproof
Cooper Crouse-Hinds Luminarea floodlights are ideally suited for area
and outdoor parking lot lighting. The floodlights are available in 3
housing sizes in 150 to 1000 watt metal halide or high pressure
sodium. The bronze epoxy powder coated housing is designed for an
extended, trouble-free life. The housing is gasketed for raintight
(NEMA 3R) locations. Floodlights are available with an optional slip
fitter or swivel bracket for mounting flexibility. Typical applications
include parking lots, area lighting, street lighting, recreational lighting
and security lighting.
Key Features and Benefits:
Materials and Finishes:
•
•
•
•
•
•
•
•
•
•
•
•
Durable die cast aluminum housing for long product life.
Bronze powder paint finish for corrosive enviroments.
Stainless steel hardware.
Hinged lens for easy access to wiring and lamp chamber.
Polished aluminum reflector maximizes light output.
Side, bottom & rear plugged threaded entries for easy wiring.
150W & 175W fixture includes adjustable mounting bracket.
250 to 1000 watt fixtures must be ordered with separate slipfitter or
swivel bracket (see page 67).
• Three housing sizes insure maximum utilization of space.
• Available in 150 to 1000 watt metal halide or high pressure sodium
versions.
Housing – Die Cast Aluminum
Lens – Tempered Glass
Gasket – Silicone
Hardware – Stainless Steel
Ratings:
•
•
•
•
150 to 1000 watt metal halide and high pressure sodium.
250 and 400 watt metal halide available with pulse start.
Multi-tap (120, 208, 240, 277 volts) or Tri-tap (120, 277, 347 volts)
480V
For accessories & dimensions, see pages 67–71
Certifications and Compliances:
• UL1598
• UL and cUL listed
• NEMA 3R raintight
Cat. #
Description
High Pressure Sodium
150
120/208/240/277
150
120/277/347
250
120/208/240/277
250
120/277/347
400
120/208/240/277
400
120/277/347
1000
120/208/240/277
1000
120/277/347
Watts
Voltage
Lamp Base
Ballast
WLFL150HPS/MT*
WLFL150HPS/TT*
WLFL250HPS/MT†
WLFL250HPS/TT†
WLFL400HPS/MT†
WLFL400HPS/TT†
WLFL1000HPS/MT‡
WLFL1000HPS/TT‡
Medium Housing
Medium Housing
16" × 16" Housing
16" × 16" Housing
16" × 16" Housing
16" × 16" Housing
23" × 23" Housing
23" × 23" Housing
Medium
Medium
Mogul
Mogul
Mogul
Mogul
Mogul
Mogul
HPF
HPF
CWA-HPF
CWA
CWA-HPF
CWA
CWA-HPF
CWA
Metal Halide
175
120/208/240/277
175
120/277/347
250
120/208/240/277
250
120/208/240/277
250
120/277/347
400
120/208/240/277
400
120/208/240/277
400
120/277/347
1000
120/208/240/277
1000
120/277/347
WLFL175MH/MT*
WLFL175MH/TT*
WLFL250MH/MT†
WLFL250MH/MT S828†
WLFL250MH/TT†
WLFL400MH/MT†
WLFL400MH/MT S828†
WLFL400MH/TT†
WLFL1000MH/MT‡
WLFL1000MH/TT‡
Medium Housing
Medium Housing
16" × 16" Housing
16" × 16" Housing, Pulse Start
16" × 16" Housing
16" × 16" Housing
16" × 16" Housing, Pulse Start
16" × 16" Housing
23" × 23" Housing
23" × 23" Housing
Medium
Medium
Mogul
Mogul
Mogul
Mogul
Mogul
Mogul
Mogul
Mogul
CWA
CWA
CWA-HPF
Pulse
CWA
CWA-HPF
Pulse
CWA
CWA-HPF
CWA
Lamp not included.
*150W & 175W Floodlight – Comes with adjustable mounting bracket with 1/ 2" thread.
†250W & 400W Floodlight – Must buy swivel bracket or slipfitter separately (see accessories, page 67).
‡1000W Floodlight – Must buy slipfitter separately (see accessories, page 67).
68
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Weatherproof Outdoor HID Luminaires
Luminarea™ Series Area Luminaires
Cooper Crouse-Hinds Luminarea wallpacks are ideally suited for
security and perimeter lighting indoors and outdoors. Wallpacks are
available in 3 housing sizes in 100 to 400 watt metal halide or high
pressure sodium. The bronze epoxy powder coated housing is
designed for an extended, trouble-free life. The housing is gasketed
for raintight (NEMA 3R) locations. The prismatic glass lens is
designed for optimal light distribution to minimize the total number of
luminaires required. Typical applications include office buildings,
stores, restaurants, warehouses, banks and parking garages.
Materials and Finishes:
•
•
•
•
•
•
•
•
•
•
•
Durable die cast aluminum housing for long product life.
Architectural bronze powder paint finish for corrosive environments.
Stainless steel hardware.
Hinged lens for easy access to wiring and lamp chamber.
Glass prismatic lens provides superior light distribution.
Top, side and rear plugged threaded entries for easy field wiring.
High power factor ballast in multi-tap (120, 208, 240, 277 volt) or tritap (120, 277, 347 volt) configurations.
• Three housing sizes insure maximum utilization of space.
• Available in 100 to 400 watt metal halide or high pressure sodium
versions.
Weatherproof
Key Features and Benefits:
Housing – Die Cast Aluminum
Lens – Tempered Glass
Gasket – Silicone
Hardware – Stainless Steel
Ratings:
• 100 to 400 watt metal halide and high pressure sodium.
• Multi-tap (120, 208, 240, 277 volts) or Tri-tap (120, 277, 347 volts)
• 480V
For accessories & dimensions, see pages 67–71
Certifications and Compliances:
• UL1598
• UL and cUL listed
• NEMA 3R raintight
Watts
Voltage
Cat. #
Description
Lamp Base
Ballast
High Pressure Sodium
100
120/208/240/277
100
120/277/347
150
120/208/240/277
150
120/277/347
250
120/208/240/277
250
120/277/347
400
120/208/240/277
400
120/277/347
WLWP100HPS/MT
WLWP100HPS/TT
WLWP150HPS/MT
WLWP150HPS/TT
WLWP250HPS/MT
WLWP250HPS/TT
WLWP400HPS/MT
WLWP400HPS/TT
Small Housing
Small Housing
Medium Housing
Medium Housing
Large Housing
Large Housing
Large Deep Housing
Large Deep Housing
Medium
Medium
Medium
Medium
Mogul
Mogul
Mogul
Mogul
HPF
HPF
HPF
HPF
CWA-HPF
CWA
CWA
CWA
Metal Halide
100
120/208/240/277
100
120/277/347
175
120/208/240/277
175
120/277/347
250
120/208/240/277
250
120/208/240/277
250
120/277/347
400
120/208/240/277
400
120/208/240/277
400
120/277/347
WLWP100MH/MT
WLWP100MH/TT
WLWP175MH/MT
WLWP175MH/TT
WLWP250MH/MT
WLWP250MH/MT S828
WLWP250MH/TT
WLWP400MH/MT
WLWP400MH/MT S828
WLWP400MH/TT
Small Housing
Small Housing
Medium Housing
Medium Housing
Large Housing
Large Housing, Pulse Start
Large Housing
Large Deep Housing
Large Deep Housing, Pulse Start
Large Deep Housing
Medium
Medium
Medium
Medium
Mogul
Mogul
Mogul
Mogul
Mogul
Mogul
HPF
HPF
CWA-HPF
CWA
CWA-HPF
Pulse
CWA
CWA
Pulse
CWA
Lamp not included.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
69
Weatherproof Outdoor HID Luminaires
Luminarea™ Series Area Luminaires
WALLPACKS
Mounting Plate
Wire Guards
Weatherproof
FLOODLIGHTS
Swivel Bracket
Cat. #
Slipfitters
Wire Guards
Description
Accessories for Wallpacks & Area Luminaires
WLWPMP 1
Mounting Plate for 100W Wallpack & Area Luminaire
WLWPWG 1
Wire Guard for 100W Wallpack
WLWPWG 2
Wire Guard for 150/175W Wallpack
WLWPWG 3
Wire Guard for 250 & 400W Wallpack
Accessories for Floodlights
WLFLSB 3
Swivel Bracket for 250 & 400W Floodlight
WLFLSF 3
Slipfitter for 250 and 400W Floodlight
WLFLSF 4
Slipfitter for 1000W Floodlight
WLFLWG 3
Wire Guard for 250 & 400W Floodlight
WLFLWG 4
Wire Guard for 1000W Floodlight
WLFLGS 2
Glare Shield for 150/175W Medium Floodlight
WLFLGS 3
Glare Shield for 250 & 400W Floodlight
WLFLGS 4
Glare Shield for 1000W Floodlight
70
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Glare Shields
Weatherproof Outdoor HID Luminaires
Luminarea™ Series Area Luminaires
Area Luminaires (Inches)
Weight: 15lbs.
100W to 175W
12.25W × 8.5H × 12.25D
Weatherproof
70W
8.75W × 7.5H × 8.75D
Floodlight Luminaires (Inches)
Weight: 15lbs.
150W & 175W
250W & 400W
1000W
9.0W × 6.75H × 5.75D
16.0W × 16.0H × 7.25D
23.0W × 23.0H × 10.25D
Wallpack Luminaires (Inches)
Weight: 15lbs.
100W
150W & 175W
250W
400W
8.5W × 9.375H × 7.0D
13.0W × 9H × 7.25D
18.0W × 9.0H × 9.75D
18.0W × 9.0H × 12.75D
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
71
Vapor Proof Lighting Incandescent
VAPOR PROOF FIXTURES – GASKETED CORROSION RESISTANT
DIE-CAST CONSTRUCTION, GLASS GLOBES, DIE-CAST GUARDS, UL LISTED
Weatherproof
TP7600, TP7601,
TP7800, TP7801,
TP7860
Cat. #
TP7610, TP7611,
TP7805
TP7620, TP7810
TP7621, TP7811
TP7630, TP7815
Hole
Size
Description
4" BOX MOUNTED
TP7600
Clear Globe, Cast Guard
TP7601
Clear Globe, Cast Guard
TP7800
Clear Globe, Wire Guard
TP7801
Clear Globe, Wire Guard
TP7860
Fluorescent Clear Globe, Wire Guard
TP7610
Clear Globe
TP7611
Clear Globe
TP7805
Clear Globe
TP7660, TP7830
Std. Unit
Carton
Wt. Lbs.
Per 100
100
100
200
200
13
100
100
200
1
1
1
1
1
1
1
1
325
324
516.7
516
413
258.3
258
283.3
1/ 2"
100
100
200
200
100
200
1
1
1
1
1
1
300
299
350
349
208.4
258.4
—
—
—
—
100
200
100
200
1
1
1
1
275
333.3
216.7
180
3/ 4"
1/ 2"
3/ 4"
1/ 2"
1/ 2"
3/ 4"
1/ 2"
1/ 2"
3/ 4"
1/ 2"
3/ 4"
1/ 2"
SURFACE MOUNT, FITS 3" and 4" ROUND BOXES
TP7640
Clear Globe, Cast Guard
TP7820
Clear Globe, Wire Guard
TP7650
Clear Globe
TP7825
Clear Globe
TP7670, TP7835
TP7650, TP7825
Watts
1/ 2"
PENDANT MOUNT
TP7620
Clear Globe, Cast Guard
TP7621
Clear Globe, Cast Guard
TP7810
Clear Globe, Wire Guard
TP7811
Clear Globe, Wire Guard
TP7630
Clear Globe
TP7815
Clear Globe
TP7640, TP7820
TP7680, TP7840, TP7870
TP7690, TP7845
Watts
Std. Unit
Carton
Wt. Lbs.
Per 100
RIGHT ANGLE BRACKET FIXTURES
TP7660
Clear Globe, Cast Guard
TP7830
Clear Globe, Wire Guard
TP7670
Clear Globe
TP7835
Clear Globe
100
200
100
200
1
1
1
1
300
516.7
200
400
BOX MOUNTED
TP7680
TP7840
TP7825
Clear Globe, Cast Guard
Clear Globe, Wire Guard
Clear Globe
100
200
200
1
1
1
350
560
450
FLUORESCENT
TP7870
Clear Globe, Wire Guard
13
1
462
Cat. #
72
Description
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Vapor Proof Lighting Incandescent
VAPOR PROOF COMPONENTS
Pendant
Ceiling Box Cap
Ceiling Box
Right Angle
Right Angle/Box
Wt. Lbs.
Per 100
PENDANT CAP, PORCELAIN SOCKET GASKET AND SCREWS
TP7496
100
Gray, 1/ 2"
TP7497
100
Gray, 3/ 4"
200
TP7498
Gray, 1/ 2"
TP7499
200
Gray, 3/ 4"
10
10
10
10
18
18
10
10
CEILING BOX CAP, SOCKET GASKET AND SCREWS
TP7447
Gray
TP7448
Gray
10
10
12
12
CEILING MOUNT BOX WITH GASKETS, PORCELAIN SOCKET AND SCREWS
TP7450
100
Gray, 1/ 2"
TP7478
100
Gray, 3/ 4"
200
TP7451
Gray, 1/ 2"
200
TP7478
Gray, 3/ 4"
10
10
10
10
19
19
19
19
RIGHT ANGLE BRACKET GASKET, SOCKET, SCREWS
TP7445
Gray
TP7446
Gray
10
6
21
12
1
1
1
1
3
3
1.5
1.5
Description
Watts
100
200
100
200
RIGHT ANGLE BRACKET ATTACHED BOX, GASKET, SOCKET AND SCREWS
TP7440
100
Gray, 1/ 2"
TP7441
100
Gray, 3/ 4"
TP7442
200
Gray, 1/ 2"
200
TP7443
Gray, 3/ 4"
Weatherproof
Std. Unit
Carton
Cat. #
VAPOR PROOF FIXTURE ACCESSORIES
TP7460 – TP7466
TP7468 – TP7472
Cat. #
Description
TP7460
TP7462
TP7463
TP7464
TP7466
TP7468
TP7469
TP7470
TP7471
TP7472
TP7474
TP7475
TP7476
TP7477
Glass Clear Globe, 130 °F Max
Glass Amber Globe
Glass Blue Globe
Glass Green Globe
Glass Clear Globe
Lexan Clear Prismatic
Lexan Blue Prismatic
Lexan Red Prismatic
Lexan Amber Prismatic
Lexan White
Bayonet Mount Die-Cast Guard
Wire Guard
Clamp-On Wire Guard
Adapter Plate
US: 1-866-764-5454
TP7474, TP7475
CAN: 1-800-265-0502
TP7476
TP7477
Watts
Std. Unit
Carton
Wt. Lbs.
Per 100
100
100
100
100
200
75
60
75
75
75
100
200
100
—
12
12
12
12
6
12
12
12
12
12
12
6
12
12
98
120
120
120
200
58.4
58.4
58.4
58.4
58.4
108.4
183.4
62.5
62.5
Copyright© 2007 Cooper Crouse-Hinds
73
Commercial Products Fixture Hangers
Flexible Fixture Hangers
Cooper Crouse-Hinds TPSFH & TPRFH flexible fixture hangers are
used in commercial or light industrial applications where HID high bay
and low bay lighting fixtures are used. Specific applications include
storage facilities, shipping warehouses, retail and DIY facilities.
Weatherproof
Features and Benefits:
• Suitable for use with 1/ 2" or 3/ 4" fixture conduit stems these hangers
allow the conduit stem of the fixture (luminaire) to swing in any
direction. Maximum swing angle is 26° from vertical max slope
angles 221/ 2°
• Available in two styles; one for attachment to round or octagonal
steel boxes, the other for attachment to 4" square steel boxes.
• Both styles are quickly and easily attached by two screws.
• Hangers are drilled and tapped for use with 3/ 4" conduit stem as
standard and come supplied with a 3/ 4" – 1/ 2" reducer for 1/ 2" conduit
stem applications.
Description
Support Wt. (lbs) Cat. #
For use with 4" Round or Octagon
Boxes
50
TPRFH12
For use with 4" Square boxes
50
TPSFH12
Certifications and Compliances:
• UL Listed – UL 1598
• CSA C22.2 No. 250
• Suitable for Damp Locations
Standard Materials and Finishes:
• Material: Sheet Steel
• Finish: Zinc Chromate for corrosion resistance
Swiv-L-Drop™ Canopy Fixture Hangers
The Swiv-L-Drop Canopy hanger utilizes a patented spring design to
provide vibration and shock protection for pendant mounted fixtures in
both horizontal and vertical directions. Designed to fit 3" or 4" outlet
boxes the Swiv-L-Drop is for use with 1/ 2" fixture conduit stems. The
smooth, white canopy provides an aesthetically pleasing appearance
and installs quickly and easily without the use of tools.
Certifications and Compliances:
Description
• UL Listed – UL 1598
• Suitable for Dry Locations
Swiv-L-Drop Canopy Hanger for use
with 3" or 4" Outlet boxes for use
with 1/ 2" Conduit Stems.
50*
S 1 1/2
Standard Materials and Finishes:
For use with 3/ 8" Conduit Stems.
50*
S 1 3/8
• Material: Sheet Steel
• Finish: Canopy – painted white
*65 lbs. rated with a minimum 12–inch stem if fully supported by other than an outlet box.
Support Wt. (lbs) Cat. #
Sway Adapters
The Sway Adapter installs quickly and easily to pendant mounted
fixtures and compensates for shocks and motion due to movements,
vibration, earthquakes or other sources by allowing for lateral
movement up to 45 degrees. The Sway Adapter can be used
independently or in conjunction with the Swiv-L-Drop hanger. The
Sway Adapter is also finished in an aesthetically pleasing white
painted finish and is designed for use with 1/ 2" conduit stems and has
3/ 8" male threads.
Certifications and Compliances:
Description
Cat. #
Sway adapter for use with 1/ 2" Conduit Stem
(male thread is 3/ 8")
SA 1W
• UL Listed – UL 1598
• Suitable for Dry Locations
Standard Materials and Finishes:
• Material: Sheet Steel
• Finish: sway adapter – painted white
74
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Photoelectric Lighting
PHOTOELECTRIC LIGHTING CONTROLS
TP7920
TP7924 – TP7925
Description
TP7920
TP7924
TP7925
TP7927
TP7928
300W Photo Cell With Plate 120V
300W Swivel Photo Cell 120V
1200W Swivel Photo Cell 120V
300W Photo Cell 120V
1000W Photo Cell 208 – 277V
Std. Unit Pkg.
10
10
10
10
10
Wt. Lbs. Per 100
50
8.3
8.3
8.3
8.3
Weatherproof
Cat. #
TP7927 – TP7928
CLOSURE PLUGS – ZINC DIE-CAST*
Cat. #
Description
TP7940
TP7942
TP7944
1/ 2"
1/ 2"
3/ 4"
Std. Unit Pkg.
Color
Wt. Lbs. Per 100
100
100
50
Gray
Bronze
Gray
1.5
1.5
2.1
*CSA Certified
Dimensions
In Inches:
Single Gang Boxes
Single Gang Deep Boxes
Two Gang Boxes
TP7010 – TP7071
TP7074 – TP7082
TP7086 – TP7122
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
75
Dimensional Data
Dimensions
Dimensions
In Inches:
76
Single Gang Boxes
Single Gang Deep Boxes
Two Gang Boxes
TP7010 – TP7071
TP7074 – TP7082
TP7086 – TP7122
Two Gang Deep Boxes
Round Boxes
Extension Rings and Flanged Boxes
TP7126 – TP7142
TP7146
TP7120
Extension Rings and Flanged Boxes
Single Gang, Duplex Receptacle Covers
TP7173 – TP7174
TP7206 – TP7209
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Dimensional Data
Dimensions
In Inches:
Two Gang, Single Receptacle Covers
Single Gang, Duplex Receptacle Covers –
Vertical Mount
TP7202
TP7220
TP7199
Two Gang, Duplex Receptacle Covers
Single Gang, GFCI Covers Horizontal
Mount
Single Gang, GFCI Covers Vertical Mount
TP7228
TP7236 – TP7238
TP7240 – TP7242
Two Gang, GFCI Covers
Blank Covers
Blank Covers
TP7248
TP7292 – TP7294
TP7296 – TP7298
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Dimensions
Single Gang, Single Receptacle Covers –
Vertical Mount
77
Dimensional Data
Dimensions
Dimensions
In Inches:
78
Blank Covers
Single Gang, Switch Covers Vertical Mount
Lampholders
TP7158
TP7256
TP7162 – TP7165
Hooded Lampholder
Rectangular Lampholder Covers
Round Lampholder Covers
TP7178
TP7312 – TP7322
TP7300 – TP7310
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Dimensional Data
VAPOR PROOF DIMENSIONS
200 WATT
Cat. #
TP7830
TP7840
TP7820
TP7810
TP7800
Length
Overall Width
Depth
121/ 2"
121/ 2"
71/ 2"
111/ 2"
103/ 4"
51/ 2"
51/ 2"
41/ 2"
51/ 2"
51/ 2"
61/ 8"
8"
—
—
—
100 WATT DIMENSIONS
Dimensions
Vapor Proof Lighting
Our Glass Globe Vapor proof fixtures comply with the latest U.L.
requirements for standard 1598, for enclosed and gasketed
incandescent fixtures.
Suitable For Wet Locations
Corrosion resistant, rugged die-cast construction castings. These
lights are designed for indoor and outdoor industrial or commercial
locations, gasketing allows their use in outdoor locations.
Designed by our engineers for fast, easy on the job site installation.
Cooper Crouse-Hinds Vapor proof series fixtures are perfect for
permanent or temporary lighting. Screw on cast guards are supplied
with allen head set screws locking it in place to help prevent
vandalism. Unit features snap-in, snap-out, copper screw shell
porcelain sockets with screws backed out.
US: 1-866-764-5454
CAN: 1-800-265-0502
• Fixtures may be purchased complete or as components.
• Fixtures constructed of Die-Cast Aluminum, Guards are Zinc DieCast.
• Heat Resistant Clear Globe Available on 100 watt series.
• Wire Guard Available.
Clear glass is standard, colors are available, plastic (polycarbonate)
globes which are virtually unbreakable are available in colors and are
used as an alternative to glass globe-guard combinations (not
recommended to exceed 60 watts).
Copyright© 2007 Cooper Crouse-Hinds
79
C
O
M
M
E
R
C
I
A
L
OUTLET BOXES
MYERS® HUBS
F
I
T
T
I
N
G
S
EMT FITTINGS
RIGID / IMC FITTINGS
GROUND BUSHINGS
Commercial
Fittings &
Accessories
OUTLET BODIES
LIQUIDTIGHT
FITTINGS
&
A
C
C
E
S
S
O
R
I
E
S
CORD AND CABLE
CONNECTORS
ARMORED CABLE
AND FMC FITTINGS
W-SERIES
JUNCTION BOXES
80
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Myers® Hubs
when installed in
accordance with the NEC.
Class I, Div. 2
Class II, Div. 1 and 2
Class III
Applications:
• Myers Scru-tite™ and Ground hub are used in the termination of
electrical circuits through wall of the enclosure
• Ideal for pharmaceutical, chemical and food processing, pulp/paper
and nuclear industries.
• Resistant to a variety of chemicals, including acetic, citric and salt
water.
• The O-ring is a special "Viton (75)" and has excellent chemical
resistance.
• Hub is provided with a stainless steel ground nut.
Features:
Vibration proof
Grounding screw for added safety
Captive o-ring gasket
No welding
Posi-Lok insulated throat (insuliner)
Fit standard knockouts
Easy installation
Controlled thread lengths
NPSL on male thread
No sharp edges (along parting line)
Hub Basic Scru-Tite® – NEMA 2, 3, 3R, 4, 4X and 12
Zinc
UL File No. E-27258
Conduit Hubs
•
•
•
•
•
•
•
•
•
•
Materials:
•
•
•
•
•
Nut: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316)
Body: Zamek-2, Zamek-3, Aluminium (Al 360), Stainless (316)
Insuliner: Lexan
O-Ring: Gasket Vi Ton
Ground Screw: Steel
Standard Finishes:
• Aluminum: Natural
• Zinc: Natural
Optional Materials and Finishes:
• Stainless: Natural
• Zinc: Chrome-plate
Certifications and Compliances:
• NEC/CEC:
Class I, Division 2
Class II, Division 1 & 2
Class III, Division 1 & 2
• UL Listed – UL Standard 514B
• CSA Certified – Certified by UL to CSA standard C22.2 No. 18
• NEMA Type 2, 3, 3R, 4, 4X, 12 (std hub)
• NEMA Type 2, 3, 3R, 4, 12 (ground hub)
Cat. #
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
03†
1†
2†
3†
4†
5†
6†
7†
8
9
10
11*
12*
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Wt. Lbs.
Per 100
25
25
25
25
10
10
10
5
2
2
2
1
1
12
20
32
40
60
70
90
200
250
300
350
600
800
Hub Basic Scru-Tite® – NEMA 2, 3, 3R, 4, 4X and 12
Aluminum
UL File No. E-27258
STA
STA
STA
STA
STA
STA
STA
STA
STA
STA
STA
STA
CAN: 1-800-265-0502
3/ 8"
Unit
Qty.
†Optional Nickel-Chrome Plate Finish. Add suffix -CP. See price list.
*Not supplied with insulator.
Cat. #
US: 1-866-764-5454
Size
1
2
3
4
5
6
7
8
9
10
11
12
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
25
25
25
10
10
10
5
2
2
2
1
1
8
16
16
30
30
50
80
100
150
150
300
300
81
Class I, Div. 2
Class II, Div. 1 and 2
Class III
Class I, ZONE 1, Ex e II
Myers® Hubs
Stainless Steel Ground Hub – NEMA 2, 3, 3R, 4, 4X
and 12
when installed in
accordance with the NEC.
Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12
Aluminum – Type 360
Stainless Steel – Type 316
UL File No. E-59509
Max. Copper
Grd. Wire Size
Conduit Hubs
Cat. #
SSTG
SSTG
SSTG
SSTG
SSTG
SSTG
SSTG
SSTG
SSTG
SSTG
Size
1/ 2"
1
2
3
4
5
6
7
8
9
10
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
10
10
10
5
5
5
2
2
2
2
20
30
43
55
73
95
—
—
—
—
Cat. #
STAG
STAG
STAG
STAG
STAG
STAG
STAG
STAG
STAG
STAG
STAG
STAG
Size
1
2
3
4
5
6
7
8
9
10
11
12
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Wt. Lbs.
Per 100
CSA
UL
25
25
25
10
10
10
5
2
2
2
1
1
10
14
18
25
33
45
90
125
138
150
325
350
#8
#8
#8
#8
#6
#4
#2
1/0
2/0
2/0
3/0
3/0
#8
#8
#8
#8
#8
#8
#6
#6
#6
#4
#2
#1
Ground Hub – NEMA 2, 3, 3R, 4, 4X and 12
Zinc
Ground Hub Basic Scru-Tite®
UL File No. E-59509
Zinc
ATEX Approval with DEMKO 07 ATEX 0618172U
II 2 G Ex e II
UL File No. 187273
Class I, Zone 1, AEx e II
Class I, Zone 1, Ex e II
Max. Copper
Grd. Wire Size
Cat. #
STG
STG
STG
STG
STG
STG
STG
STG
STG
STG
STG
STG
1
2
3
4
5
6
7
8
9
10
11*
12*
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Wt. Lbs.
Per 100
CSA
UL
25
25
25
10
10
10
5
2
2
2
1
1
20
30
43
55
73
95
190
263
300
350
625
750
#8
#8
#8
#8
#6
#4
#2
1/0
2/0
2/0
2/0
3/0
#8
#8
#8
#8
#8
#8
#6
#6
#6
#4
#2
#1
Cat. #
STGK
STGK
STGK
STGK
STGK
STGK
1
2
3
4
5
6
Size
Unit Qty.
Wt. Lbs.
Per 100
1/ 2"
10
10
10
5
5
5
20
30
43
55
73
95
3/ 4"
1"
11/ 4"
11/ 2"
2"
*Not supplied with insulator
82
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
when installed in
accordance with the NEC.
Class I, Div. 2
Class II, Div. 1 and 2
Class III
Class I, ZONE 1, Ex e II
Myers® Hubs
Stainless Steel – Type 316
Cap-Off
ATEX Approval with DEMKO 07 ATEX 0618172U
Zinc
II 2 G Ex e II
UL File No. E-187273
Class I, Zone 1, AEx e II
Class I, Zone 1, Ex e II
Cat. #
Cat. #
SSTGK
SSTGK
SSTGK
SSTGK
SSTGK
SSTGK
1
2
3
4
5
6
Size
Unit Qty.
Wt. Lbs.
Per 100
1/ 2"
10
10
10
5
5
5
20
30
43
55
73
95
3/ 4"
1
11/ 4"
11/ 2"
2
STC
STC
STC
STC
STC
STC
1
2
3
4
5
6
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
25
25
25
10
10
10
13
20
28
40
53
70
3/ 4"
1"
11/ 4"
11/ 2"
2"
Cap-Off
Aluminum
Ground Nut
Zinc
Cat. #
STGN
STGN
STGN
STGN
STGN
STGN
Size
1/ 2"
1
2
3
4
5
6
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
CSA
UL
25
25
25
10
10
10
6
10
13
15
23
30
#8
#8
#8
#8
#6
#4
#8
#8
#8
#8
#8
#8
Ground Nut
Aluminum
Max. Copper
Grd. Wire
Size
Cat. #
STAGN
STAGN
STAGN
STAGN
STAGN
STAGN
Size
1
2
3
4
5
6
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
CSA
UL
25
25
25
10
10
10
3
5
6
8
10
13
#8
#8
#8
#8
#6
#4
#8
#8
#8
#8
#8
#8
STAC 1
STAC 2
STAC 3
Wt. Lbs. Per 100
25
25
25
6
8
12
1"
Through-Bulkhead Fitting
Zinc
Cat. #
STTB
STTB
STTB
STTB
STTB
STTB
STTB
STTB
STTB
STTB
1
2
3
4
5
6
7
8
9
10
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
5
5
5
5
5
5
4
2
2
2
30
50
70
85
110
160
244
312
350
400
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Through-Bulkhead Fitting
Aluminum
STTBA
STTBA
STTBA
STTBA
STTBA
STTBA
STTBA
STTBA
CAN: 1-800-265-0502
Unit Qty.
1/ 2"
3/ 4"
Cat. #
US: 1-866-764-5454
Size
Conduit Hubs
Cat. #
Max. Copper
Grd. Wire Size
1
2
3
4
5
6
7
8
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
5
5
5
5
5
5
4
2
20
35
30
40
50
70
106
138
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
Copyright© 2007 Cooper Crouse-Hinds
83
when installed in
accordance with the NEC.
Class I, Div. 2
Class II, Div. 1 and 2
Class III
Class I, ZONE 1, Ex e II
Myers® Hubs
Through-Bulkhead Fitting without nipples
Metric To NPT Adapter
Zinc
Zinc
Cat. #
STTTB
STTTB
STTTB
STTTB
STTTB
STTTB
1
2
3
4
5
6
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
5
5
5
5
5
5
35
60
75
85
120
170
3/ 4"
1"
11/ 4"
11/ 2"
2"
Through–Bulkhead Fitting without nipples
Aluminum
Cat. #
Size
Unit Qty.
Wt. Lbs. Per 100
M20 to 1/ 2"
M25 to 3/ 4"
M32 to 1"
M40 to 11/ 4"
M50 to 11/ 2"
M63 to 2"
25
25
25
10
10
10
12
32
32
40
50
70
STM
STM
STM
STM
STM
STM
1
2
3
4
5
6
Note:
The Myers Metric to NPT hub adapter is used to convert a threaded metric entry to
a NPT entry. The female thread is NPT and the male thread is metric.
Metric To NPT Adapter
Stainless Steel
Conduit Hubs
Cat. #
STTTBA
STTTBA
STTTBA
STTTBA
STTTBA
STTTBA
1
2
3
4
5
6
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
5
5
5
5
5
5
15
25
35
40
50
75
3/ 4"
1"
11/ 4"
11/ 2"
2"
Non-Hazadous Drain Plug
Stainless Steel
UL File No. E-23223
Cat. #
SSTC 1
SSTC 1CD
Note:
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
25
10
13
13
1/ 2"
Cat. #
SSTM
SSTM
SSTM
SSTM
SSTM
SSTM
Size
1
2
3
4
5
6
1/ 2"
M20 to
M25 to 3/ 4"
M32 to 1"
M40 to 11/ 4"
M50 to 11/ 2"
M63 to 2"
SSTC-1 is for knockouts and is supplied with a locknut and straight threads.
SSTC-1CD is for threaded openings and is supplied without locknut and NPT
threads. Not gasketed to allow for water drainage
Non-Hazadous Drain Plug
Aluminum
UL File No. E-23223
Cat. #
STAC 1ST
STAC 1CD
Note:
84
Size
Unit Qty.
Wt. Lbs. Per 100
1/ 2"
25
25
6
6
1/ 2"
STAC-1ST is for knockouts and is supplied with a locknut and straight threads.
STAC-1CD is for threaded openings and is supplied without locknut and NPT
threads. Not gasketed to allow for water drainage
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Unit Qty.
Wt. Lbs. Per 100
10
10
10
5
5
5
12
20
32
40
50
70
Myers® Hubs
SCHEDULE OF DIMENSIONS
PIPE
SIZE
E
J "O" RING
Cat. #
A
B
C
D
MIN.
MAX.
ST 02
13/ 2
15/ 16
21/ 32
1/ 8
.350
.364
1/ 4
3/ 8
ST 03†
13/ 2
11/ 8
21/ 32
1/ 8
.468
1/ 2
ST 1†
111/ 32
17/ 16
13/ 16
3/ 16
.591
3/ 4
ST 2†
115/ 32
123/ 32
29/ 32
3/ 16
.783
1
ST 3†
121/ 32
2
11/ 32
1/ 4
.997
1.049
1 NPT
11/ 4
1.311
1.380
1/ 4
F
G
K
H
C.S.
O.D.
MIN.
60°
3/ 21
3/ 4
35/ 64
MAX.
9/ 16
15/ 16
43/ 64
11/ 16
NPT
1/ 4
.493
3/ 8
NPT
3/ 8
NPS
60°
3/ 32
.622
3/ 4
NPT
3/ 4
NPS
60°
1/ 8
11/ 2
55/ 64
7/ 8
.824
1/ 2
NPT
1/ 2
NPS
60°
1/ 8
17/ 16
11/ 16
11/ 8
1 NPS
60°
1/ 8
13/ 4
121/ 64
13/ 8
11/ 4 NPT
11/ 4 NPS
60°
1/ 8
21/ 8
143/ 64
13/ 4
11/ 2
11/ 2
21/ 2
159/ 64
2
21/ 2
NPS
111/ 16
23/ 8
11/ 32
1/ 4
ST 5†
111/ 16
23/ 4
11/ 32
1/ 4
1.529
1.610
60°
1/ 8
2
ST 6†
13/ 4
31/ 4
13/ 32
1/ 4
1.964
2.067
2 NPT
2 NPS
60°
1/ 8
3
225/ 64
21/ 2
ST 7
27/ 32
33/ 4
19/ 32
1/ 4
2.346
2.469
21/ 2 NPT
21/ 2 NPS
60°
1/ 8
31/ 2
257/ 64
3
3
ST 8
25/ 16
43/ 8
13/ 8
1/ 4
2.915
3.068
3 NPT
3 NPS
45°
1/ 8
41/ 8
333/ 64
35/ 8
31/ 2
ST 9
23/ 8
5
17/ 16
1/ 4
3.371
3.548
31/ 2 NPT
31/ 2 NPS
45°
1/ 8
45/ 8
41/ 64
41/ 8
4
ST 10
27/ 16
51/ 2
11/ 2
1/ 4
3.825
4.026
4 NPT
4 NPS
45°
1/ 8
51/ 8
433/ 64
45/ 8
5
ST 11*
215/ 16
67/ 8
2
1/ 4
4.795
5.047
5 NPT
5 NPS
45°
1/ 8
61/ 2
537/ 64
511/ 16
3
711/ 16
2
5/ 16
45°
1/ 8
71/ 4
641/ 64
63/ 4
6
ST 12*
5.762
6.065
NPT
6 NPT
NPS
6 NPS
Conduit Hubs
ST 4†
11/ 2
*Not supplied with insulator.
Options:
Tolerance
Description
† Optional Nickel-Chrome Plate Finish. See price list.
Suffix
-CP
Decimal
Fractional
Angular & Draft
+/–.010
+/–1/16
+/–2°
Cat. #
Material
ST
STA
SSTG
Zinc
Aluminium
Stainless
Dimensions and materials specified are subject to change without prior notice.
PLAN VIEW SIDE VIEW
"D" dimension indicated maximum panel thickness which hub will accommodate.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
85
Myers® Hubs
SPACING CHART FOR MYERS HUBS
Conduit Hubs
CONDUIT OR PIPE SIZE
HOLE
SIZE.
COND.
SIZE.
1/ 4
9/ 16
1/ 4
11/ 16
11/ 16
3/ 8
15/ 32
11/ 4
7/ 8
1/ 2
15/ 16
113/ 32
19/ 16
11/ 8
3/ 4
17/ 16
117/ 32
111/ 16
113/ 16
13/ 8
1
19/ 32
111/ 16
127/ 32
131/ 32
21/ 8
13/ 4
11/ 4
125/ 32
17/ 8
21/ 32
25/ 32
25/ 16
21/ 2
2
3/ 8
1/ 2
3/ 4
1
11/4
11/2
2
21/2
3
31/2
11/ 2
131/ 32
21/ 16
27/ 32
211/ 32
21/ 2
211/ 16
27/ 8
21/ 2
2
27/ 32
25/ 16
215/ 32
219/ 32
23/ 4
215/ 16
31/ 8
33/ 8
3
21/ 2
215/ 32
29/ 16
223/ 32
227/ 32
3
33/ 16
33/ 8
35/ 8
37/ 8
35/ 8
3
225/ 32
27/ 8
31/ 32
35/ 32
35/ 16
31/ 2
311/ 16
35/ 16
43/ 16
41/ 2
41/ 8
31/ 2
33/ 32
33/ 16
311/ 32
315/ 32
35/ 8
313/ 16
4
41/ 4
41/ 2
413/ 16
51/ 8
45/ 8
4
5
6
4
311/ 32
37/ 16
319/ 32
323/ 32
37/ 8
41/ 16
41/ 4
41/ 2
43/ 4
51/ 16
53/ 8
53/ 4
511/ 16
5
41/ 32
41/ 8
49/ 32
413/ 32
49/ 16
43/ 4
415/ 16
53/ 16
57/ 16
53/ 4
61/ 16
63/ 16
71/ 8
63/ 4
6
413/ 32
41/ 2
421/ 32
425/ 32
415/ 16
51/ 8
55/ 16
59/ 16
513/ 16
61/ 8
67/ 16
611/ 16
73/ 8
73/ 4
19/ 32
11/ 16
27/ 32
31/ 32
11/ 8
15/ 16
11/ 2
13/ 4
2
25/ 16
25/ 8
27/ 8
39/ 16
315/ 16
Minimum space from center of pipe or conduit to nearest obstruction.
1. Dimensions in black squares are centers for conduits of same size. Example: How close may 3 conduits be spaced?
Answer 41/ 2"
2.Dimensions in gray squares are for centers of conduits NOT of the same size. Example: What is the minimum spacing for 2" and 3/ 4" conduit?
Read down column marked 3/ 4" to figure opposite 2" and find dimensions is 211/ 32".
3.Minimum spacing dimensions as shown will give approximately 1/ 8" clearance between locking nuts.
86
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Conduit Hubs
Malleable Iron Conduit Hubs
Applications:
Iron Space Saver Conduit Hubs
Applications:
• Ideal for terminating electrical
conduit through the walls of
enclosures.
• Designed for use indoors or
outdoors with rigid conduit and
IMC, specific applications
include food processing plants,
distilleries, breweries, sewage
disposal plants, chemical plants,
paper processing mills and
refineries.
• Ideal for terminating electrical conduit through the walls of
enclosures.
• Designed for use indoors or outdoors with rigid conduit and IMC,
specific applications include food processing plants, distilleries,
breweries, sewage disposal plants, chemical plants, paper
processing mills and refineries.
Features:
Features:
Certifications and Compliances:
•
•
•
•
•
•
•
Class I, Division 2 – NEC 501.4 (B)
Class II, Divisions 1 & 2 – NEC 502.4 (A) (B)
Class III, Divisions 1 & 2 – NEC 503.3 (A) (B)
UL Listed – UL Standard 514B
cUL Listed – Certified by UL to CSA Standard C22.2 No. 18
NEMA: FB-1
Suitable for wet locations
Conduit Hubs
• Male thread type
• Tapered female thread for rigid conduit and IMC
• Recessed O-ring gasket assures raintight and dust tight
connections
• Insulated throat provides smooth pulling surface
• Locking screw on the nut doubles as a grounding screw for added
safety
• Complete size range from 1/ 2" to 6"
• Hubs fit standard knockouts. No special tools required
• Male thread is on the nut for
space saving.
• Quick and easy when installing
rigid conduit nipple between two
existing enclosures.
• Insulated throat provides smooth
pulling surface.
• Furnished with SG sealing gasket.
• Hub fits standard knockouts. No
special tools required.
Certifications and Compliances:
•
•
•
•
•
•
•
Class I, Division 2 - NEC 501.4(B).
Class II, Divisions 1 & 2 - NEC 502.4(A)(B).
Class III, Division 1 & 2 - NEC 503.3(A)(B).
UL Listed - UL Standard 514B.
cUL Listed - Certified by UL to CSA Standard C22.2 No. 18.
NEMA: FB-1
Suitable for wet locations.
Standard Materials & Finishes:
• Material: Malleable Iron
• Finish: Zinc Electroplate
Dimensions
In Inches:
Cat. #
MHUB1
MHUB2
MHUB3
MHUB4
MHUB5
MHUB6
MHUB7
MHUB8
MHUB9
MHUB10
MHUB11
MHUB12
Trade Size
Unit Qty.
Std. Pkg.
Wt. Lbs. Per 100
1/ 2"
25
25
5
5
2
1
1
1
1
1
1
1
100
100
50
25
20
10
10
5
5
2
1
1
18
25
50
25
20
10
10
5
5
2
1
1
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Conduit
Size
Cat. #
HUB1
HUB2
HUB3
HUB4
HUB5
HUB6
HUB7
HUB8
HUB9
HUB10
Note:
US: 1-866-764-5454
CAN: 1-800-265-0502
1/ 2
3/ 4
1
11/ 4
11/ 2
2
21/ 2
3
31/ 2
4
Unit
Qty.
25
10
5
5
2
1
1
1
1
1
Wt. Lbs.
Per 100
18
25
50
25
20
10
10
5
5
2
a
b
1
11/ 8
13/ 8
11/ 2
15/ 8
111/ 16
23/ 16
27/ 16
27/ 16
29/ 16
11/ 4
19/ 16
17/ 8
25/ 16
21/ 2
3
35/ 8
41/ 4
43/ 4
51/ 4
c
1
13/ 8
15/ 8
2
23/ 8
213/ 16
37/ 16
41/ 16
411/ 16
51/ 16
d
x
1/ 8 9/ 64
5/ 32 1/ 4
3/ 16 9/ 32
1/ 4 7/ 16
1/ 4 7/ 16
1/ 4 7/ 16
1/ 4 7/ 16
1/ 4 7/ 16
5/ 16 3/ 4
5/ 16 11/ 8
Dimension "x" is maximum wall thickness of box that will meet the requirement for
three full threads engagement of nipple and fitting body when box connector or rigid
conduit hub is installed in a knockout or slip hole.
Copyright© 2007 Cooper Crouse-Hinds
87
Commercial Products Fixture Hangers
Flexible Fixture Hangers
Fixture Hangers
Cooper Crouse-Hinds TPSFH & TPRFH flexible fixture hangers are
used in commercial or light industrial applications where HID high bay
and low bay lighting fixtures are used. Specific applications include
storage facilities, shipping warehouses, retail and DIY facilities.
Features and Benefits:
• Suitable for use with 1/ 2" or 3/ 4" fixture conduit stems these hangers
allow the conduit stem of the fixture (luminaire) to swing in any
direction. Maximum swing angle is 26° from vertical max slope
angles 221/ 2°
• Available in two styles; one for attachment to round or octagonal
steel boxes, the other for attachment to 4" square steel boxes.
• Both styles are quickly and easily attached by two screws.
• Hangers are drilled and tapped for use with 3/ 4" conduit stem as
standard and come supplied with a 3/ 4" – 1/ 2" reducer for 1/ 2" conduit
stem applications.
Description
For use with 4" Round or Octagon Boxes
For use with 4" Square boxes
Support
Wt. (lbs) Cat. #
50
50
TPRFH12
TPSFH12
Certifications and Compliances:
• UL Listed - UL 1598
• CSA C22.2 No. 250
• Suitable for Damp Locations
Standard Materials and Finishes:
• Material: Sheet Steel
• Finish: Zinc Chromate for corrosion resistance
Swiv-L-Drop™ Canopy Fixture Hangers
The Swiv-L-Drop Canopy hanger utilizes a patented spring design to
provide vibration and shock protection for pendant mounted fixtures in
both horizontal and vertical directions. Designed to fit 3" or 4" outlet
boxes the Swiv-L-Drop is for use with 1/ 2" fixture conduit stems. The
smooth, white canopy provides an aesthetically pleasing appearance
and installs quickly and easily without the use of tools.
Certifications and Compliances:
Description
• UL Listed - UL 1598
• Suitable for Dry Locations
Standard Materials and Finishes:
• Material: Sheet Steel
• Finish: Canopy – painted white
Support
Wt. (lbs) Cat. #
Swiv-L-Drop Canopy Hanger for use with 3"
or 4" Outlet boxes for use with 1/ 2" Conduit
Stems.
50*
S 1 1/2
For use with 3/ 8" Conduit Stems.
50*
S 1 3/8
*65 lbs. rated with a minimum 12–inch stem if fully supported by other than an outlet box.
Sway Adapters
The Sway Adapter installs quickly and easily to pendant mounted
fixtures and compensates for shocks and motion due to movements,
vibration, earthquakes or other sources by allowing for lateral
movement up to 45 degrees. The Sway Adapter can be used
independently or in conjunction with the Swiv-L-Drop hanger. The
Sway Adapter is also finished in an aesthetically pleasing white
painted finish and is designed for use with 1/ 2" conduit stems and has
3/ 8" male threads.
Certifications and Compliances:
Description
Cat. #
Sway adapter for use with 1/ 2" Conduit Stem
(male thread is 3/ 8")
SA 1W
• UL Listed – UL 1598
• Suitable for Dry Locations
Standard Materials and Finishes:
• Material: Sheet Steel
• Finish: Sway Adapter – painted white
88
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Thin Wall Conduit Fittings
(For EMT Conduit)
•
•
•
•
Raintight
Compression Type Fittings
Straight Connectors
Couplings
COMPRESSION TYPE FITTINGS –
RAINTIGHT CONNECTORS
Applications:
Straight Connectors – Non-Insulated – Raintight
UL File No. E-22132
• The Cooper Crouse-Hinds Raintight EMT connectors are used to
join EMT conduit to a box or enclosure in Raintight environments.
• The design prevents water seepage into conduit, box or enclosure.
Features and Benefits:
Certifications and Compliances:
•
•
•
•
UL Listed
cUL Listed
Concrete Tight
Raintight
Size
650RT
651RT
652RT
653RT
654RT
655RT
656RT
657RT
658RT
659RT
1/ 2"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
25
10
10
5
2
1
1
1
250
125
100
50
50
25
10
5
5
5
11
17
23
41
50
67
177
234
280
360
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
25
10
10
5
2
1
1
1
250
125
100
50
50
25
10
5
5
5
14
21
28
49
60
79
187
245
390
485
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Couplings – Raintight
UL File No. E-22132
Cat. #
Size
660RT
661RT
662RT
663RT
664RT
665RT
666RT
667RT
668RT
669RT
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Thinwall Fittings
• All steel construction with zinc electroplate finish provides for
durable corrosion resistance
• Flat surface on Gland nut provides smooth, flat surface for easy
wrenching
• Distinct black gland nut provides quick raintight identification
• Integral gasketed compression ring secures and seals for reliable
installation
• Interior shoulder conduit stop provides positive seating of conduit
inside the body
• Gasket on male threads of box connector seals installation for
raintight connection between the box and the connector
• Available in insulated and non-insulated versions to meet any
customer preference
• Angled teeth on locknut for secure bite into enclosure
• Extruded locknut with shoulder provides more threads for more
secure installation
• Concrete tight
• Standard material: Steel
• Standard finish: Zinc plated
Cat. #
Straight Connectors – Insulated – Raintight
UL File No. E-22132
Cat. #
1650RT
1651RT
1652RT
1653RT
1654RT
1655RT
1656RT
1657RT
1658RT
1659RT
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
25
10
10
5
2
1
1
1
250
125
100
50
50
25
10
5
5
5
11
17
23
41
50
67
177
234
330
360
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
89
Thin Wall Conduit Fittings
(For EMT Conduit)
• Compression Type Fittings
• Straight Connectors
• Couplings
COMPRESSION TYPE FITTINGS – STEEL
Applications:
Straight Connectors – Non-Insulated
UL File No. E-22132
Thinwall conduit fittings are used:
• To join EMT to a box or enclosure
• To couple two ends of EMT conduit
Features:
Compression Type
• Unique raised bump design affords fast, positive locking of
compression nuts
• Male Hub Threads - NPSM
• Steel Locknuts
• Heavy Steel Walls
• Standard Material: Steel
• Standard Finish: Zinc Plated
Concrete Tight Straight Connectors – Insulated
UL File No. E-22132
Cat. #
Size
650S
651S
652
653
654
655
656
657
658
659
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
25
10
10
5
2
1
1
1
9
16
25
43
54
76
190
300
280
360
Unit
Qty.
Wt. Lbs.
Per 100
50
25
25
10
10
5
2
1
1
1
12
18
27
46
63
92
250
410
390
485
Couplings
Thinwall Fittings
UL File No. E-22132
Cat. #
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
90
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
25
10
10
5
2
1
1
1
11
16
25
43
54
76
190
300
330
360
US: 1-866-764-5454
CAN: 1-800-265-0502
Cat. #
Size
660S
661S
662
663
664
665
666
667
668
669
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
Thin Wall Conduit Fittings
(For EMT Conduit)
• Compression Type Fittings
• Set Screw Type Fittings
• Combination Couplings
SPACE-SAVER EMT SET-SCREW
& COMPRESSION CONNECTORS
- STEEL
COMBINATION COUPLINGS – STEEL
UL File No. E22132
UL File No. E-19189
Concrete Tight
EMT (Compression) To Rigid (Threaded)
Applications:
• Use to join EMT conduit to box or enclosure
Features:
Cooper Crouse-Hinds
Space Saver EMT
Connector (on right)
provides maximum
useable space inside
the box unlike a
traditional connector
with bushing.
Traditional EMT
connector protrudes
inside box and
creates the
cumbersome and
labor intensive need
to clip the device
mounting screw to
install device.
Cat. #
690S
691
692
Size
1/ 2"
– 1/ 2"
– 3/ 4"
1" – 1"
3/ 4"
Unit
Qty.
Wt. Lbs.
Per 100
25
20
10
9
13
19
Thinwall Fittings
• Male threads on locknut allow for more room inside the box
• Smooth pulling surface won’t strip cable – no bushing or insulated
throat required
• Angled teeth on locknut bite into enclosure, preventing loosening
from vibration
• Knurled wrenching surface for easy tightening
• Zinc electroplated for corrosion resistance
• Concrete tight when taped
SET-SCREW CONNECTOR
• Tri-head set screw may be installed using a slotted, Phillips, or
Robertson head screwdriver
COMPRESSION CONNECTOR
• The split compression ring assures solid attachment to the conduit
and good ground continuity
• The hex surface on the compression nut provide for easy wrenching
to quickly and easily tighten the nut
The Space Saver
EMT Connector's low
profile design
eliminates this
cumbersome and
labor intensive
requirement.
Certifications and Compliances:
• UL Listed
• CUL Listed
Set Screw Type Connector
Compression Connector
Unit
Qty.
Wt. Lbs.
Per 100
1"
100
50
25
8
12
12
Compression Connector
1/ 2"
SSC50
3/ 4"
SSC75
SSC100
1"
50
25
25
8
12
12
Cat. #
Set Screw Connector
SSBC50
SSBC75
SSBC100
Size
1/ 2"
3/ 4"
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
91
Thin Wall Conduit Fittings
(For EMT Conduit)
• Set Screw Type Fittings
• Combination Couplings
Couplings
SET SCREW TYPE FITTINGS
Features:
•
•
•
•
•
•
•
UL File No. E-22132
Pre-set & Staked Robertson Head Screws
Male Hub Threads - NPSM
Steel Locknuts
Heavy Steel Walls
Standard Material: Steel
Standard Finish: Zinc Plated
Concrete Tight when taped
Straight Connectors – Insulated
UL File No. E-22132
Thinwall Fittings
Cat. #
Size
1/ 2"
1450
1451
1452
1453*
1454*
1455*
1456*†
1457*†
1458*†
1459*†
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
20
10
10
5
2
1
1
1
9
14
23
46
50
78
130
140
180
225
Cat. #
Size
460
461
462
463*
464*
465*
466*†
467*†
468*†
469*†
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
20
10
10
5
2
1
1
1
9
16
23
42
50
77
130
140
240
250
*Four Tightening Screws
†UL and cUL Listed for EMT, IMC and Rigid Conduit
COMBINATION COUPLINGS – STEEL
Standard Materials:
• Steel
Standard Finishes:
• Zinc plated
EMT (Set Screw) to Rigid (Set Screw)
UL File No. E-19819
*Two Tightening Screws
†UL and cUL Listed for EMT, IMC and Rigid Conduit
Straight Connectors – Non-Insulated
UL File No. E-22132
Cat. #
420
421
422
Cat. #
Size
450S
451
452
453*
454*
455*
456*
457*
458*
459*
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
20
10
10
5
2
1
1
1
9
15
23
46
50
77
130
140
180
225
Size
1/ 2"
3/ 4"
1"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
20
10
100
100
50
17
25
37
*Two Tightening Screw
92
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Thin Wall Conduit Fittings
(For EMT Conduit)
•
•
•
•
•
Set Screw Type Fittings
Combination Couplings
Straight Connectors
Couplings
Offset Connectors
SET SCREW TYPE FITTINGS –
ZINC DIE CAST
Features:
Couplings
UL File No. E-22132
• Tri-head Set Screw may be installed using a slottted, Phillips or
Robertson head screwdriver
• Concrete Tight when taped
Standard Materials:
Cat. #
• Zinc
460DC
461DC
462DC
463DC*
464DC*
465DC*
466DC*
467DC*
468DC*
469DC*
Standard Finishes:
• Natural
Straight Connectors – Insulated
UL File No. E-22132
Size
Unit
Qty.
Std
Pkg.
Wt. Lbs.
Per 100
50
25
20
10
10
5
12
12
6
6
500
250
200
100
60
20
12
12
6
6
5
7
13
18
28
36
64
81
98
116
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
*Four Tightening Screws
Cat. #
Size
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Std
Pkg.
Wt. Lbs.
Per 100
50
25
25
10
10
5
12
12
6
6
500
250
200
100
60
40
12
12
6
6
5
8
11
20
25
37
59
78
101
120
Offset Connectors – Non-Insulated
UL File No. E-22132
Cat. #
2400
2401
2402
Size
1/ 2"
3/ 4"
1"
Unit
Qty.
Wt. Lbs.
Per 100
10
10
10
11
18
25
Thinwall Fittings
1/ 2"
1450DC
1451DC
1452DC
1453DC*
1454DC*
1455DC*
1456DC*
1457DC*
1458DC*
1459DC*
Unit
Qty.
*Two Tightening Screws
Straight Connectors – Non-Insulated
UL File No. E-22132
Cat. #
450DC
451DC
452DC
453DC*
454DC*
455DC*
456DC*
457DC*
458DC*
459DC*
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std
Pkg.
Wt. Lbs.
Per 100
50
25
25
10
10
5
12
12
6
6
500
250
200
100
60
40
12
12
6
6
5
7
11
21
25
36
58
77
98
117
*Two Tightening Screws
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
93
Thin Wall Conduit Fittings
(For EMT Conduit)
•
•
•
•
Compression Type Fittings
Combination Couplings
Straight Connectors
Couplings
COMPRESSION TYPE FITTINGS –
ZINC DIE CAST
Features:
Couplings
UL File No. E-22132
• The split compression ring assures solid attachment to the conduit
and good ground continuity
• The hex surfaces on the compression nut provide for easy
wrenching to quickly and easily tighten the nut
• Concrete tight
Standard Materials:
• Zinc
Standard Finishes:
• Natural
Straight Connectors – Insulated
UL File No. E-22132
Cat. #
Size
660DC
661DC
662DC
663DC
664DC
665DC
666DC
667DC
668DC
669DC
1/ 2"
Unit
Qty.
Std
Pkg.
Wt. Lbs.
Per 100
50
25
15
10
10
5
12
12
6
6
500
250
150
100
50
20
12
12
6
6
11
16
22
40
48
64
124
144
190
228
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Thinwall Fittings
COMBINATION COUPLINGS – ZINC DIE
CAST
Cat. #
1650DC
1651DC
1652DC
1653DC
1654DC
1655DC
1656DC
1657DC
1658DC
1659DC
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std
Pkg.
Wt. Lbs.
Per 100
50
25
15
10
10
5
12
12
6
6
500
250
150
100
40
20
12
12
6
6
8
11
17
31
39
56
93
120
149
172
EMT (Set Screw) to Rigid (Set Screw) Concrete Tight
UL File No. E-19189
Cat. #
2420
2421
Size
1/ 2"
3/ 4"
– 1/ 2"
– 3/ 4"
Straight Connectors – Non-Insulated
UL File No. E-22132
Cat. #
Size
650DC
651DC
652DC
653DC
654DC
655DC
656DC
657DC
658DC
659DC
1/ 2"
94
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std
Pkg.
Wt. Lbs.
Per 100
50
25
15
10
10
5
12
12
6
6
500
250
150
100
40
20
12
12
6
6
8
11
17
31
39
56
93
120
149
172
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
50
25
8
12
Thin Wall Conduit Fittings
(For EMT Conduit)
•
•
•
•
•
Combination Couplings
90° Pulling Elbows
Straps
Clamps
Clampbacks/Spacers
COMBINATION COUPLINGS – ZINC DIE
CAST
Two Hole
EMT (Set Screw) to Flexible Steel (Clamp)
UL File No. E-184283
STRAPS – STEEL GALVANIZED
UL File No. E-19189
Cat. #
Size
Unit
Qty.
780DC
1/ 2"– 3/ 8"
50
Std.
Pkg.
Wt. Lbs.
Per 100
500
8
Cat. #
90 DEGREE PULLING ELBOWS – ZINC DIE
CAST
Applications:
• To connect EMT to form a 90° bend, or to connect EMT to box or
enclosure
• Removable cover and gasket facilitate wire pulling
1/ 2"
3/ 4"
1"
11/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Wt. Lbs.
Per 100
250
150
100
50
50
25
25
25
25
10
1500
300
—
—
—
—
—
—
—
—
2
3
5
8
13
14
19
23
93
108
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
A
B
C
D
20
15
6
3
200
150
60
30
17
24
54
80
1.77
2.13
3.18
3.26
1.02
1.28
1.54
1.91
.42
.43
.50
.63
.61
.77
.98
1.29
A = Length of cover, B = Width (not shown)
Cat. #
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
516*
517*
518*
519*
21/ 2"
3"
31/ 2"
4"
5
2
2
2
30
12
12
12
104
120
150
220
Thinwall Fittings
850EB DC
875EB DC
8100EB DC
8125EB DC
3/ 4"
Std.
Pkg.
UL File No. E-184283
UL File No. E-22132
Size
1/ 2"
1
2
3
4
5
6
9
10
11
12
Unit
Qty.
CLAMPS – MALLEABLE IRON
EMT To Box
Cat. #
497
497
497
497
497
497
496
496
496
496
Size
*Also for use with Rigid/IMC Conduit
EMT To EMT
CLAMPBACKS/SPACERS – IRON
Applications:
UL File No. E-22132
• Provides space between conduit and mounting surface
Standard Materials:
• Malleable Iron
Standard Finishes:
Cat. #
850EE DC
875EE DC
8100EE DC
8125EE DC
Size
1/ 2"
3/ 4"
1"
11/ 4"
• Zinc plated
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
A
B
C
D
20
15
6
3
200
150
60
30
15
22
52
80
1.77
2.13
3.18
3.26
1.02
1.28
1.54
1.91
.59
.80
.98
1.29
.93
1.18
1.53
1.91
A = Length of cover, B = Width (not shown)
UL File No. E-184283
Cat. #
Size
CB1
CB2
CB3
CB4
CB5
CB6
CB7
CB8
CB9
CB10
CB11†
CB12†
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
25
25
25
25
10
10
10
10
10
5
5
300
300
100
100
100
60
60
60
10
10
5
5
8
10
12
21
42
40
49
62
91
110
135
225
†Not UL Listed
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
95
Thin Wall Conduit Fittings
(For EMT Conduit)
• Clamps "Snap-On"
• Nailing Straps
• Bendsaver
CLAMPS "SNAP-ON" – STEEL
Applications:
BENDSAVER CONDUIT STRAPS
AND COUPLINGS
Features:
• To support EMT conduit to mounting surface
Heavy Gauge
UL File No. E-184283
Cat. #
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
100
100
50
25
25
25
25
10
10
500
500
500
250
100
25
25
25
10
10
5
6
6
13
17
20
64
71
120
130
1/ 2"
200
201
202
203
204
205
206*
207*
208*
209*
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
• Never offset bend 1/ 2" and 3/ 4" EMT conduit again when running
EMT into a junction box. Stand-off design eliminates conduit
bending and provides automatic alignment with electrical box
knockouts.
• Only one strap and one coupling are required per conduit run
• Patented design eliminates conduit bending and allows for
automatic alignment of EMT to box knockouts
• Conduit straps are steel with zinc plating, couplings are zinc die cast
Certifications and Compliances:
• UL Listed
• cUL Listed
Specification Grade
Steel Bendsaver Conduit Straps for EMT and Zinc Diecast Bendsaver
Coupling
Thinwall Fittings
*Not UL LIsted
NAILING STRAPS – CAST STEEL
Standard Materials:
Steel Bendsaver strap
• Cast Steel
Standard Finishes:
• Zinc plated
Support EMT, IMC and rigid conduit to mounting
surface
Conduit Sizes
Cat. #
EMT
Rigid
NS 1
NS 2
NS 3
1/ 2"
3/ 8"
1"
3/ 4"
3/ 4"
1/ 2"
Unit
Qty.
Wt. Lbs.
Per 100
100
100
100
2
2
3
Old way requires two
straps, one coupling
and two offset bends
Zinc die cast
Bendsaver coupling
Cat. #
Size
Dimensions
Cat. #
A
B
C
D
NS 1
NS 2
NS 3
3/ 16
1
11/ 4
11/ 2
17/ 8
2
21/ 2
3/ 4
15/ 16
3/ 4
3/ 16
BSS50
BSS75
BSC50DC
BSC75DC
11/ 8
1/ 2"
3/ 4"
1/ 2"
3/ 4"
NAILING STRAPS – STAMPED STEEL
Conduit Sizes
Cat. #
EMT
Rigid
NSS1
NSS2
NSS3
1/ 2"
3/ 8"
1"
3/ 4"
96
3/ 4"
1/ 2"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
100
100
1000
1000
1000
2
2
3
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
With the Bendsaver
fittings, no offset
bends are required
and only one strap
and one coupling!
Unit
Qty.
Wt. Lbs.
Per 100
100
50
100
50
8
9
9
14
Rigid/Intermediate Grade
Conduit Fittings
Concrete Tight
• Type CPR Compression Fittings
TYPE CPR COMPRESSION FITTINGS
Features and Benefits:
Straight Connectors – Insulated
UL File No. E-19189
• UL Listed for use with IMC as well as metallic rigid conduit.
• Unequalled versatility for the installer.
• Unique gland ring design tightens up in fewer turns; provides
outstanding pull-out strength; saves time and adds confidence.
• Advanced, thoughtful design and premium materials team up for an
installation you can be proud of.
Cat. #
Applications:
Use type CPR compression fittings for:
• Both IMC and metallic rigid conduit.
• New work in poured concrete.
• Maintenance, repairs and alterations.
• Connections at panels and boxes.
• New, altered or damaged stubups.
• Applicable locations where field threading is impractical or
undesirable.
Certifications and Compliances:
CPR11
CPR12
CPR13
CPR14
CPR15
CPR16
CPR17
CPR18
CPR19
CPR20
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
10
10
5
5
2
1
1
1
250
125
50
50
25
25
10
5
5
5
19
23
42
64
87
113
130
220
280
320
Straight Connectors – Non-Insulated
• UL 514B Fittings for Conduit and Outlet Boxes
UL File No. E-19189
Standard Materials:
Bodies – malleable iron
Compression nuts – iron
Compression rings – stainless steel
Locknuts – zinc plated steel
Insuliners – glass-reinforced polypropylene
Cat. #
CPR1
CPR2
CPR3
CPR4
CPR5
CPR6
CPR7
CPR8
CPR9
CPR10
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
10
10
5
5
2
1
1
1
250
125
50
50
25
25
10
5
5
5
19
23
42
64
87
113
130
220
280
320
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
20
10
5
5
2
2
1
1
1
125
100
50
25
25
10
10
5
5
5
26
38
59
85
124
162
220
320
380
440
Rigid Intermediate
•
•
•
•
•
Couplings
UL File No. E-19189
Cat. #
CPR21
CPR22
CPR23
CPR24
CPR25
CPR26
CPR27
CPR28
CPR29
CPR30
US: 1-866-764-5454
CAN: 1-800-265-0502
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
97
Rigid/Intermediate Grade
Conduit Fittings
Concrete Tight
• Set Screw Type Fittings
SET SCREW TYPE FITTINGS
SET SCREW TYPE FITTINGS
Straight Connectors – Insulated
Couplings
UL File No. E-19189
UL File No. E-19189
Cat. #
150S
151
152
153
154
155*
1456*†
1457*†
1458*†
1459*†
160I*†§
161I*†§
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
5
10
5
2
2
1
1
1
1
1
200
100
50
50
25
10
10
5
5
1
1
1
16
27
40
50
76
110
210
282
380
400
850
1100
Rigid Intermediate
*Two Tightening Screws
†Malleable Iron
§Not CSA Certified
Cat. #
160
161
162
163
164
165*
466*†
467*†
468*†
469*†
170C*†§
171C*†§
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
20
5
10
5
2
2
1
1
1
1
1
100
100
50
50
25
10
10
5
1
1
1
1
27
40
52
70
104
160
300
400
500
600
1500
1800
*Four Tightening Screws
†Malleable Iron
§Not CSA Certified
Notes:
1456 – 1459, 456 – 459 & 466 – 469 are dual listed for EMT, Rigid, and IMC conduit.
Straight Connectors – Non-Insulated
UL File No. E-19189
Cat. #
150P
151P
152P
153P
154P
155P*
456*
457*
458*
459*
160P*†§
161P*†§
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
5
10
5
2
2
1
1
1
1
1
200
100
50
50
25
10
10
5
5
1
1
1
16
26
40
50
76
110
210
281
380
400
850
1100
*Two Tightening Screws
†Malleable Iron
§Not CSA Certified
98
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Rigid/Intermediate Grade
Conduit Fittings
Concrete Tight
Raintight (SSR Series)
• Set Screw Type Fittings
• Combination Couplings
SET SCREW TYPE FITTINGS
Straight Connectors – Insulated
U. S. Patent #3951436
Applications:
Cat. #
Rainboot™ connectors and couplings are used with rigid conduit for
IMC, steel or aluminum. Outdoors or indoors. Use Rainboot fittings for:
• Conduit systems expansion and alterations.
• Maintenance and repair operations.
• New, altered or damaged stubups.
• Connections at panels and boxes.
• Embedment in concrete.
• Installations in tight quarters: near corners, walls, ceilings,
overhangs, obstacles or adjacent raceways.
• Situations where threading equipment or heavy pipe wrenches are
impractical.
• Conduit systems in NEC wet locations.
SSR11
SSR12
SSR13
SSR14
SSR15
SSR16
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Wt. Lbs.
Per 100
20
20
20
5
5
4
20
30
40
64
85
97
Straight Connectors – Non-Insulated
Cat. #
Size
• The only line of rigid/IMC threadless fittings suitable for raintight
applications.
• The only alternative to field threading in NEC wet locations.
• May be installed in any position.
• Tough and durable, long lasting, trouble free installations.
• Requires only a 3/ 8" wrench for installation.
• Full line – 1/ 2" through 2".
• Faster, easier method to install raintight rigid/IMC raceway systems.
SSR1
SSR2
SSR3
SSR4
SSR5
SSR6*
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
20
20
20
5
5
4
21
23
40
64
85
96
Rigid Intermediate
Features and Benefits:
Standard Materials:
Unit
Qty.
*Two Tightening Screws
For sealing at enclosure, use Type SG sealing gaskets (see page 125).
Couplings
• Bodies
Connectors – 1/ 2" – 2" steel
Couplings – 1/ 2" – 2" steel
• Boots – injection molded PVC attached with special epoxy.
• Setscrews hardened steel coated with special sealing resin
compound.
Cat. #
Size
1/ 2"
SSR21
SSR22
SSR23
SSR24
SSR25
SSR26†
Certifications and Compliances:
• UL 514B – Fittings for cable and conduit
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
20
20
5
5
4
4
31
45
64
86
116
165
†Four Tightening Screws
COMBINATION COUPLINGS – STEEL
Concrete Tight
EMT (Compression) To Rigid (Threaded)
UL File No. E-19189
Cat. #
690S
691
692
US: 1-866-764-5454
CAN: 1-800-265-0502
Size
1/ 2"
– 1/ 2"
– 3/ 4"
1" – 1"
3/ 4"
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
25
20
10
9
13
19
99
• Combination Couplings
• Fitting Locknuts
• Grounding Locknuts
Rigid/Intermediate
Grade Conduit Fittings
COMBINATION COUPLINGS
FITTING LOCKNUTS
Combination Couplings – Zinc Plated Steel
Concrete Tight
Steel
EMT (Set Screw) To Rigid (Set Screw)
UL File No. E-19189
Cat. #
420
421
422
Size
1/ 2"
– 1/ 2"
3/ 4" – 3/ 4"
1" – 1"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
20
10
100
100
50
17
25
37
Combination Couplings – Malleable Iron
Flexible Steel (Squeeze Type) To Rigid (Threaded)
Cat. #
Rigid Intermediate
65
66
67
68
Size
1/ 2"
–
3/ 4" –
1" –
11/ 4" –
1/ 2"
3/ 4"
1"
11/ 4"
Unit
Qty.
Wt. Lbs.
Per 100
10
10
5
5
17
22
31
31
Cat. #
Size
1/ 2"
11X
12X
13X
14X
15X
16X
17X
18X
19X
20X
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
500
100
50
100
50
50
25
20
10
10
2500
1000
500
500
250
250
100
100
50
50
1
1
3
3
4
4
10
15
18
22
GROUNDING LOCKNUTS
Applications:
• For use with bushing to bond 1/ 2" to 4" rigid conduit to boxes,
cabinets or other enclosures, only where a locknut is exposed.
Steel
Combination Couplings – Zinc Die Cast
UL File No. E-6225
Concrete Tight
EMT (Set Screw) To Rigid (Set Screw)
UL File No. E-19189
Cat. #
2420
2421
100
Size
1/ 2"
– 1/ 2"
3/ 4" – 3/ 4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
500
250
8
12
US: 1-866-764-5454
CAN: 1-800-265-0502
Cat. #
GL
GL
GL
GL
GL
GL
GL
GL
GL
GL
11
12
13
14
15
16
17
18
19
20
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
50
50
50
50
25
20
10
10
5
1000
500
500
250
250
100
100
50
50
25
2
3
4
6
7
9
28
38
48
52
Copyright© 2007 Cooper Crouse-Hinds
• Conduit Locknuts
• Insulated Throat Bushings
• Non-Insulated Throat brushings
Rigid/Intermediate
Grade Conduit Fittings
CONDUIT LOCKNUTS
THROAT BUSHINGS
3/ 8"
Malleable Iron Threaded 105°C Rated Plastic Throat
Liner
– 2" Steel,
21/2"
– 6" Malleable Iron
UL File No. E-19189
UL File No. E-19189
Cat. #
Size
3/ 8"
10
11
12
13
14
15
16
17
18
19
20
22
23
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
100
100
50
100
50
50
20
10
10
5
2
1
2500
2500
1000
500
500
250
250
100
50
50
25
2
1
1
1
2
3
4
5
7
10
15
18
22
79
166
Insulated
Cat. #
Size
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041*
1042*
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Wt. Lbs.
Per 100
100
100
50
50
10
20
10
10
5
5
1
1
3
4
7
15
19
22
44
54
72
95
100
127
*Not UL Listed
Aluminum
11
12
13
14
15
16
17
18
19
20
Size
1/ 2"
SA
SA
SA
SA
SA
SA
SA
SA
SA
SA
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
100
100
50
100
50
50
20
10
10
5
1
1
1
2
2
3
9
13
16
52
Zinc Die Cast
Cat. #
Size
11DC
12DC
13DC
14DC
15DC
16DC
17DC
18DC
19DC
20DC
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
400
250
100
60
50
30
20
15
10
10
4000
2500
1000
600
500
300
200
150
100
100
1
1
2
3
5
8
10
15
16
19
US: 1-866-764-5454
CAN: 1-800-265-0502
Rigid Intermediate
Cat. #
Non-Insulated
Cat. #
Size
1/ 2"
1031NI
1032NI
1033NI
1034NI
1035NI
1036NI
1037NI
1038NI
1039NI
1040NI
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
100
100
50
50
10
20
10
10
5
5
3
4
7
15
19
22
44
54
72
95
Set Screw Type – Threadless 105°C Rated Plastic
Throat Liner
UL File No. E-19189
Cat. #
Size
S1031
S1032
S1033
S1034
S1035
S1036
S1037
S1038
S1039
S1040
S1041
S1042
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
100
100
50
50
10
20
10
10
5
5
1
1
3
4
7
15
19
22
44
54
72
95
100
127
101
Rigid/Intermediate
Grade Conduit Fittings
•
•
•
•
Insulated Throat Grounding Bushings
Threaded
Copper or Aluminum Ground Lug
105°C Rated & 150°C Rated
INSULATED THROAT GROUNDING
BUSHINGS
Applications:
Aluminum Lug – For Copper Or Aluminum
Grounding Conductors – Threaded 105°C Rated
Plastic Throat Liner
UL File No. E-6225
• For use on threaded rigid/IMC conduit to provide a means of
grounding conduit through an insulated bushing
Malleable Iron-105°C Rated Plastic Throat Liner
Copper Lug – For Copper Grounding Conductors –
Threaded
UL File No. E-6225
Trade
Size
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
5
9
12
GLL4
GLL4 10
GLL5
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
19
23
24
GLL5 10
GLL6
GLL6 10
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
28
26
32
GLL7
GLL7 30
GLL7 250
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
53
60
67
GLL8
GLL8 30
GLL8 250
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
70
72
76
GLL9
GLL9 250
GLL10
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
100
100
110
GLL10 250
GLL11
GLL11 250
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
120
140
143
GLL12
GLL12 250
6"
6"
#3/0 – #6
250MCM – #6
1
1
160
163
Cat. #
GLL1
GLL2
GLL3
Trade
Size
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
8
12
14
GLL4 10C
GLL4C
GLL5 10C
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
19
30
21
GLL5C
GLL6C
GLL6 10C
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
32
29
40
GLL7C
GLL7 30C
GLL7 250C
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
65
88
97
GLL8C
GLL8 30C
GLL8 250C
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
77
100
109
GLL9C
GLL9 250C
GLL10C
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
125
134
145
GLL10 250C
GLL11C
GLL11 250C
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
154
165
174
GLL12C
GLL12 250C
6"
6"
#3/0 – #6
250MCM – #6
1
1
195
204
Cat. #
Rigid Intermediate
GLL1C
GLL2C
GLL3C
3/ 4"
Zinc Die Cast – 150°C Rated Plastic Throat Liner
Aluminum Lug – for Copper or
Aluminum Grounding Conductors
UL File No. E-6225
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
GLL1 DC
GLL2 DC
GLL3 DC
1/ 2"
1"
50
40
25
500
400
250
3
4
5
GLL4 DC
GLL5 DC
GLL6 DC
11/ 4"
11/ 2"
2"
25
25
10
250
250
100
9
10
14
GLL7 DC
GLL8 DC
GLL9 DC
GLL10 DC
21/ 2"
3"
31/ 2"
4"
5
5
4
4
50
50
40
40
25
33
38
44
Cat. #
102
US: 1-866-764-5454
CAN: 1-800-265-0502
3/ 4"
3/ 4"
Copyright© 2007 Cooper Crouse-Hinds
Rigid/Intermediate
Grade Conduit Fittings
•
•
•
•
Insulated Throat Grounding Bushings
Threadless
Copper or Aluminum Ground Lug
105°C Rated
Aluminum Lug – For Copper Or Aluminum
Grounding Conductors – Threadless
– Set Screw Type 105°C Rated Plastic Throat Liner
INSULATED THROAT GROUNDING
BUSHINGS
Applications:
UL File No. E-6225
• For use on threaded rigid/IMC conduit to provide a means of
grounding conduit through an insulated bushing
Copper Lug – For Copper Grounding Conductors –
Threadless
– Set Screw Type 105°C Rated Plastic Throat Liner
UL File No. E-6225
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
5
9
12
GLS4
GLS4 10
GLS5
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
19
23
24
GLS5 10
GLS6
GLS6 10
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
28
26
32
GLS7
GLS7 30
GLS7 250
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
53
60
67
GLS8
GLS8 30
GLS8 250
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
70
72
76
GLS9
GLS9 250
GLS10
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
100
100
110
GLS10 250
GLS11
GLS11 250
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
120
140
143
GLS12
GLS12 250
6"
6"
#3/0 – #6
250MCM – #6
1
1
160
163
GLS1
GLS2
GLS3
Trade
Size
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
8
12
14
GLS4C
GLS4 10C
GLS5C
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
19
30
21
GLS5 10C
GLS6C
GLS6 10C
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
32
29
40
GLS 7C
GLS7 30C
GLS7 250C
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
65
88
97
GLS8C
GLS8 30C
GLS8 250C
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
77
100
109
GLS9C
GLS9 250C
GLS10C
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
125
134
145
GLS10 250C
GLS11C
GLS11 250C
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
154
165
174
GLS12C
GLS12 250C
6"
6"
#3/0 – #6
250MCM – #6
1
1
195
204
Cat. #
GLS1C
GLS2C
GLS3C
3/ 4"
US: 1-866-764-5454
CAN: 1-800-265-0502
3/ 4"
Copyright© 2007 Cooper Crouse-Hinds
Rigid Intermediate
Trade
Size
Cat. #
103
• Insulating Bushings
• Insulated Throat Bushings
• Threaded and Threadless
Rigid/Intermediate
Grade Conduit Fittings
INSULATING BUSHINGS
Standard Materials:
150°C Rated
Threadless Set Screw Type
UL File No. E-19189
• Plastic
UL File No. E-19189
Rated 105°C
Cat. #
Rated 150°C
Cat. #
931
932
933
934
935
936
937
938
939
940
941
942
H
H
H
H
H
H
H
H
H
H
H
H
931
932
933
934
935
936
937
938
939
940
941
942
Trade
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
50
50
50
50
25
25
10
10
5
5
5
5
1
1
2
3
3
4
8
10
11
11
40
42
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Cat. #
Trade
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
100
100
50
50
10
20
10
10
5
5
1
1
6
7
10
13
15
21
42
51
65
80
100
128
HS1031
HS1032
HS1033
HS1034
HS1035
HS1036
HS1037
HS1038
HS1039
HS1040
HS1041
HS1042
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Rigid Intermediate
150°C Rated – Zinc Die Cast
Threaded
UL File No. E-19189
INSULATED THROAT BUSHINGS
Features:
• Plastic liner will not chip, crack, swell or shrink. It resists corrosion,
chemicals and temperature extremes.
Standard Materials:
• Body – Malleable Iron
• Insuliner – ULTEM1000 rated at 150°C
Cat. #
H1031DC
H1032DC
H1033DC
H1034DC
H1035DC
H1036DC
H1037DC
H1038DC
H1039DC
H1040DC
Standard Finishes:
• Body – Zinc Plated
150°C Rated
Threaded
UL File No. E-19189
Cat. #
H1031
H1032
H1033
H1034
H1035
H1036
H1037
H1038
H1039
H1040
H1041
H1042
104
Trade
Size
Unit
Qty.
Wt. Lbs.
per 100
1/ 2"
100
100
50
50
10
20
10
10
5
5
1
1
6
8
11
14
17
24
51
62
85
104
130
167
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
US: 1-866-764-5454
CAN: 1-800-265-0502
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
per 100
1/ 2"
100
100
50
50
20
10
10
5
5
2
1000
1000
500
100
100
50
25
25
25
20
2
3
5
7
9
11
27
33
39
46
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
Rigid/Intermediate
Grade Conduit Fittings
• Insulated Throat Grounding Bushings
• Threaded
Malleable Iron – 150°C Rated
INSULATED THROAT GROUNDING
BUSHINGS
Features:
Aluminum Lug – For Copper Or Aluminum Grounding Conductors –
Threaded
UL File No. E-6225
• Resilient plastic liner, resists corrosion, chemicals and temperature
extremes
• Insuliner – ULTEM1000 rated at 150°C
• 1 Set screw provided with each fitting locks bushing in any desired
position
• External stainless steel hardware as standard
Standard Finishes:
• Zinc Plated
Copper Lug – For Copper Grounding Conductors – Threaded
UL File No. E-6225
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
12
14
17
HGLL4C
HGLL4 10C
HGLL5C
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
20
32
23
HGLL5 10C
HGLL 6C
HGLL6 10C
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
35
30
42
HGLL7C
HGLL7 30C
HGLL7 250C
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
69
92
101
HGLL8C
HGLL8 30C
HGLL8 250C
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
80
103
112
HGLL9C
HGLL9 250C
HGLL10C
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
126
135
145
HGLL10 250C
HGLL 11C
HGLL11 250C
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
155
171
180
HGLL 12C
HGLL 12 250C
6"
6"
#3/0 – #6
250MCM – #6
1
1
210
317
3/ 4"
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
9
11
14
HGLL 4
HGLL4 10
HGLL 5
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
17
24
20
HGLL5 10
HGLL 6
HGLL6 10
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
24
27
31
HGLL 7
HGLL7 30
HGLL7 250
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
58
67
70
HGLL 8
HGLL8 30
HGLL8 250
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
69
78
81
HGLL 9
HGLL9 250
HGLL 10
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
101
104
120
HGLL10 250
HGLL 11
HGLL 11 250
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
123
145
150
HGLL 12
HGLL 12 250
6"
6"
#3/0 – #6
250MCM – #6
1
1
185
186
US: 1-866-764-5454
CAN: 1-800-265-0502
3/ 4"
Copyright© 2007 Cooper Crouse-Hinds
Rigid Intermediate
Trade
Size
Cat. #
Lug
Size
HGLL 1
HGLL 2
HGLL 3
Malleable Iron – 150°C Rated
HGLL1C
HGLL2C
HGLL3C
Trade
Size
Cat. #
105
Rigid/Intermediate
Grade Conduit Fittings
• Insulated Throat Grounding Bushings
• Threadless
INSULATED THROAT GROUNDING
BUSHINGS
Features:
Malleable Iron – 150°C Rated
Set Screw Type – Aluminum Lug – For Copper Or Aluminum
Grounding Conductors – Threadless
UL File No. E-6225
• Resilient plastic liner resists corossion, chemicals and temperature
extremes
• Insuliner – ULTEM1000 rated at 150°C
• 2 Set-screws provided with each fitting, locks bushings in any
desired position
Standard Finishes:
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
9
10
13
HGLS4
HGLS4 10
HGLS5
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
16
20
18
HGLS5 10
HGLS6
HGLS6 10
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
22
24
28
HGLS7
HGLS7 30
HGLS7 250
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
50
58
60
HGLS8
HGLS8 30
HGLS8 250
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
58
67
70
HGLS9
HGLS9 250
HGLS10
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
80
85
90
HGLS10 250
HGLS11
HGLS11 250
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
100
115
120
HGLS12
HGLS12 250
6"
6"
#3/0 – #6
250MCM – #6
1
1
145
150
Cat. #
Malleable Iron – 150°C Rated
HGLS1
HGLS2
HGLS3
Set Screw Type – Copper Lug – For Copper Grounding Conductors
– Threadless
UL File No. E-6225
Trade
Size
Lug
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
1"
#4 – #14
#4 – #14
#4 – #14
50
50
50
12
13
16
HGLS4C
HGLS4 10C
HGLS5C
11/ 4"
11/ 4"
11/ 2"
#4 – #14
#1/0 – #8
#4 – #14
25
25
10
19
31
21
HGLS5 10C
HGLS6C
HGLS6 10C
11/ 2"
2"
2"
#1/0 – #8
#4 – #14
#1/0 – #8
10
10
10
33
27
39
HGLS7C
HGLS7 30C
HGLS7 250C
21/ 2"
21/ 2"
21/ 2"
#1/0 – #8
#3/0 – #6
250MCM – #6
10
10
10
60
83
92
HGLS8C
HGLS8 30C
HGLS8 250C
3"
3"
3"
#1/0 – #8
#3/0 – #6
250MCM – #6
5
5
5
70
92
100
HGLS9C
HGLS9 250C
HGLS10C
31/ 2"
31/ 2"
4"
#3/0 – #6
250MCM – #6
#3/0 – #6
1
1
1
105
115
100
HGLS10 250C
HGLS11C
HGLS11 250C
4"
5"
5"
250MCM – #6
#3/0 – #6
250MCM – #6
1
1
1
130
140
150
HGLS12C
HGLS12 250C
6"
6"
#3/0 – #6
250MCM – #6
1
1
170
180
Cat. #
Rigid Intermediate
Trade
Size
• Body – Zinc Plated
HGLS1C
HGLS2C
HGLS3C
106
3/ 4"
US: 1-866-764-5454
CAN: 1-800-265-0502
3/ 4"
Copyright© 2007 Cooper Crouse-Hinds
• Three Piece Conduit Couplings
• Conduit Bushed Nipples
Rigid/Intermediate
Grade Conduit Fittings
THREE PIECE CONDUIT COUPLINGS
Applications:
CONDUIT BUSHED NIPPLES
Applications:
• Used to join two lengths of threaded conduit. Couples conduit when
conduit cannot be turned.
• Used thru knockout to connect box to conduit coupling.
• Used with a locknut to connect two boxes side by side or back to
back.
• Used with a locknut to connect fixture housing to continuous runs.
Standard Materials:
• Heavy duty casting
Standard Finishes:
Malleable Iron
• Zinc Plated
Non-Insulated Threaded NPSM for rigid conduit and IMC
UL File No. E-19189
Malleable Iron (Concrete Tight)
UL File No. E-19189
Cat. #
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Std.
Pkg.
Wt. Lbs.
Per 100
25
25
10
5
5
5
2
1
1
1
1
1
150
100
60
30
30
30
12
5
5
1
1
1
23
35
60
91
167
215
430
463
655
800
1200
2100
†Not UL Listed
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
10
10
10
10
5
5
1
1
1
1
3
8
13
19
30
37
68
92
130
200
350
425
Unit
Qty.
Wt. Lbs.
Per 100
50
25
10
10
10
10
5
5
1
1
1
1
3
4
11
19
30
37
72
96
113
187
350
450
Rigid Intermediate
Cat. #
190M
191
192
193
194
195
196
197
198
199
188†
189†
Unit
Qty.
50*
51
52
53
54
55
56
57
58
59
60†
61†
Size
*Steel
†Not UL Listed
Insulated
UL File No. E-19189
Cat. #
Size
1050*
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
*Steel
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
107
• Conduit Bushed Nipples
• 90° Pull Elbows
• Offset Conduit Nipples
Rigid/Intermediate
Grade Conduit Fittings
CONDUIT BUSHED NIPPLES – ZINC DIE
CAST
Non-Insulated
UL File No. E-19189
Cat. #
50D
51D
52D
53D
54D
55D
56D
57D
58D
59D
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
• For connecting threaded rigid or IMC to form a 90° bend, or for
connecting rigid or IMC to box or enclosure
• Removable cover and gasket facilitate wire pulling
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Standard Materials:
100
50
25
10
25
10
10
10
10
5
1000
500
100
100
100
50
30
—
—
—
4
5
10
11
20
30
40
49
68
70
Gasketed – Liquidtight
Rigid to Box
Rigid Intermediate
90 DEGREE PULL ELBOWS – MALLEABLE
IRON
Features:
•
•
•
•
•
•
•
90 DEGREE PULL ELBOWS – ZINC DIE
CAST
Applications:
Raintight
Furnished with Neoprene gasketed steel cover
Furnished with Steel lock nut
Furnished with Stamped Steel cover
Threaded for rigid conduit and IMC
For outdoor use
Standard Finish: Zinc plated
• Body — zinc
• Gasket — neoprene
• Cover — aluminum
UL File No. E-19189
Cat. #
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
per 100
1"
11/ 4"
20
15
6
3
200
150
60
30
17
25
53
80
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
20
15
6
3
200
150
60
30
15
23
50
80
Size
1/ 2"
850RB DC
875RB DC
8100RB DC
8125RB DC
3/ 4"
Rigid to Rigid
UL File No. E-19189
Gasketed – Liquidtight
Male To Female
UL File No. E-19189
Cat. #
1/ 2"
850RR DC
875RR DC
8100RR DC
8125RR DC
Cat. #
810
811
812
813
814
815
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
20
10
5
2
2
1
34
56
88
92
200
344
3/ 4"
1"
11/ 4"
OFFSET CONDUIT NIPPLES – MALLEABLE
IRON
Features:
• Threaded NPSM for rigid conduit and IMC
• Standard Finish: Zinc Plated
• USE: To offset the axis of raceways 3/ 4 of an inch
Female To Female
UL File No. E-19189
Cat. #
Cat. #
820
821
822
823
824
825
108
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
20
10
5
2
2
1
36
49
94
140
200
344
US: 1-866-764-5454
CAN: 1-800-265-0502
300
301
302
303
Size
1/ 2"
3/ 4"
1"
11/ 4"
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
25
25
10
10
24
34
49
54
•
•
•
•
Rigid/Intermediate
Grade Conduit Fittings
Offset Conduit Nipples
Knockout Snap-In Blanks
Push Plugs
Bushing Pennies
OFFSET CONDUIT NIPPLES – ZINC DIE
CAST
PUSH PLUGS – PLASTIC*
UL File No. E-19189
Cat. #
300DC
301DC
302DC
303DC
304DC
305DC
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
10
10
10
5
5
2
200
200
200
200
200
200
9
15
21
33
40
65
KNOCKOUT SNAP-IN BLANKS – STEEL
Cat. #
PPC
PPC
PPC
PPC
PPC
PPC
PPC
PPC
PPC
PPC
Size
1/ 2"
50
75
100
125
150
200
250
300
350
400
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
100
100
50
50
25
25
100
100
50
50
1
1
1
1
1
1
2
3
6
8
*Temperature Rating: 180° – 200°F
Tensile Strength: 600 – 2300 PSI
Cat. #
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Wt. Lbs.
Per 100
100
100
50
50
50
20
2
2
2
3
5
7
BUSHING PENNIES – STEEL
Applications:
• A penny under a bushing will seal the end of conduit during
construction.
Cat. #
90
91
92
93
94
95
96
97
98
99
US: 1-866-764-5454
CAN: 1-800-265-0502
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
100
100
100
50
50
50
50
50
50
50
1
1
1
1
2
3
5
7
10
14
Rigid Intermediate
335
336
337
338
339
340
Unit
Qty.
109
• Knockout Reducing Washers
• Nailing Straps
Rigid/Intermediate
Grade Conduit Fittings
KNOCKOUT REDUCING WASHERS –
STEEL
NAILING STRAPS – CAST STEEL
Standard Materials:
• Cast Steel
Standard Finishes:
• Zinc plated
Rigid Intermediate
Cat. #
Size
Std.
Pkg.
Wt. Lbs.
Per 100
100
100
100
2500
100
100
1
2
2
342
343
344
3/ 4"
345
346
347
11/ 4"
–
11/ 4" – 3/ 4"
11/ 4" – 1"
100
100
100
100
100
100
3
2
2
348
349
350S
11/ 2" – 1/ 2"
11/ 2" – 3/ 4"
11/ 2 – 1"
50
50
50
50
50
50
5
4
4
351
352
353
11/ 2 – 11/ 4"
2" – 1/ 2"
2" – 3/ 4
50
50
50
50
50
50
3
7
7
354
355
356
2" – 1"
2" – 11/ 4"
2" – 11/ 2"
50
50
50
50
50
50
6
5
3
360
361
362
21/ 2" – 1/ 2"
21/ 2" – 3/ 4"
21/ 2" – 1"
25
25
25
250
250
250
7
7
7
363
364
365
21/ 2" – 11/ 4"
21/ 2" – 11/ 2
21/ 2" – 2"
25
25
25
250
250
250
7
7
7
366
367
368
3" – 1"
3" – 11/ 4"
3" – 11/ 2"
25
25
25
250
250
250
14
14
14
369
370 S
371
3" – 2"
3" – 21/ 2"
3" – 11/ 2"
25
25
25
250
250
100
14
14
25
372
373
374
31/ 2" – 2"
31/ 2" – 21/ 2"
31/ 2" – 3"
25
25
25
100
100
100
25
25
25
375
376
377
378
4" – 2"
4" – 21/ 2"
4" – 3"
4" – 31/ 2"
25
25
25
25
100
100
100
100
35
35
35
35
110
– 1/ 2"
1" – 1/ 2"
1" – 3/ 4"
Unit
Qty.
1/ 2"
US: 1-866-764-5454
CAN: 1-800-265-0502
Support rigid conduit and IMC to mounting surface
Conduit Sizes
Cat. #
EMT
Rigid
NS 1
NS 2
NS 3
1/ 2"
3/ 8"
1"
3/ 4"
3/ 4"
1/ 2"
Unit
Qty.
Wt. Lbs.
Per 100
100
100
100
2
2
3
Dimensions
In Inches:
Cat. #
A
NS 1
NS 2
NS 3
3/ 16
3/ 4
3/ 16
B
C
D
1
11/ 4
11/ 2
17/ 8
3/ 4
2
21/ 2
15/ 16
11/ 8
NAILING STRAPS – STAMPED
STEEL
Conduit Sizes
Cat. #
EMT
Rigid
NSS1
NSS2
NSS3
1/ 2"
3/ 8"
1"
3/ 4"
3/ 4"
1/ 2"
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
100
100
1000
1000
1000
2
2
3
• Conduit Clamps
Rigid/Intermediate
Grade Conduit Fittings
CLAMPS – MALLEABLE IRON
Applications:
STRAPS – STEEL GALVANIZED
Applications:
• To support rigid conduit and IMC to mounting surface
• Used to secure rigid conduit or IMC to mounting surface
UL File No. E-184283
Two Hole
UL File No. E-184283
Cat. #
510
511
512
513
514
515
516*
517*
518*
519*
520†
521†
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
50
50
25
20
10
5
2
2
2
1
1
600
300
300
100
120
60
30
12
12
12
5
5
6
8
13
20
30
64
104
120
150
220
380
690
*Also for use with Thinwall (EMT) Conduit
†Not UL Listed
• To provide space between conduit and mounting surface
496
496
496
496
496
496
496
496
496
496
496
Size
3/ 8"
2
3
4
5
6
7
8
9
10
11
12
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
250
150
100
50
50
50
25
25
25
25
10
2
2
3
7
8
10
15
19
23
93
108
Rigid Intermediate
CLAMPBACKS/SPACERS – MALLEABLE
IRON
Applications:
Cat. #
CLAMPS "SNAP-ON" – STEEL
Applications:
• To support rigid conduit and IMC to mounting surface
Heavy Gauge
UL File No. E-184283
UL File No. E-184283
Cat. #
Size
CB1
CB2
CB3
CB4
CB5
CB6
CB7
CB8
CB9
CB10
CB11†
CB12†
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
25
25
25
25
10
10
10
10
10
5
5
300
300
100
100
100
60
60
60
10
10
5
5
8
10
12
21
42
40
49
62
91
110
135
225
Cat. #
410*
411*
412*
413*
414
415
206*
207*
208*
209*
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
50
50
50
25
25
25
25
10
10
500
500
250
250
100
25
25
25
10
10
5
6
11
13
20
22
64
71
120
130
*CSA Certified
†Not UL Listed
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
111
• Conduit Clamps
Rigid/Intermediate
Grade Conduit Fittings
CABLE AND CONDUIT HANGERS – STEEL
With Bolt
CONDUIT CLAMPS
Applications:
• Right Angle – to attach the conduit run at a 90° angle to a beam or
structural member
• Paralled Type – to attach the conduit run parallel to a beam or
structural member
Conduit
Size
EMT
Cat. #
1/ 2"
Rigid Intermediate
0B
1B
2B
2 1/2 B
3 B
4 B
5 B
6 B
7 B
8 B
9 B
3/ 4"
Conduit
Sizes
Rigid
3/ 8"
1"
11/ 4"
11/ 2"
—
2"
21/ 2"
3"
31/ 2"
4"
& 1/ 2"
3/ 4"
1"
—
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4
Right Angle Type – Electrogalvanized – Iron
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
100
100
100
100
100
50
50
25
10
10
400
400
600
—
—
—
—
—
—
—
—
6
6
8
10
11
16
23
29
31
38
38
BEAM CLAMPS/INSULATOR SUPPORTS –
MALLEABLE IRON
Standard Finishes:
Cat. #
RAC50HD
RAC75HD
RAC100HD
RAC125HD
RAC150HD
RAC200HD
RAC250HD
RAC300HD
RAC350HD
RAC400HD
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Load
Rating
Lbs
Std.
Pkg.
Wt. Lbs.
Per 100
30
50
60
75
80
100
125
165
200
330
50
50
50
25
25
25
10
10
10
10
37
40
42
49
54
71
95
107
120
131
• Zinc Plated
Parallel Type – Electrogalvanized – Iron
UL File No. E-184283
Base
Cat. # Size
528
529
530
531
532
533
534
Jaw Max. Wt.
Open Support
3/ 4"
5/ 8"
1"
1"
11/ 2"
2"
21/ 2"
3/ 4"
3/ 4"
5/ 8"
3/ 4"
3/ 4"
7/ 8"
7/ 8"
230
230
230
230
290
330
800
Tapped
Holes
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
10 – 24
– 20
10 – 24
1/ 4" – 20
5/ 16" – 18
3/ 8" – 16
1/ 2" – 13
25
25
25
25
50
25
25
100
100
100
100
50
—
—
14
13
23
24
47
81
155
1/ 4"
Beam Clamps/Insulator Supports – Steel
Cat. #
Base
Size
Jaw
Opening
529 S
3/ 4"
5/ 8"
112
Tapped
Holes
1/ 4"
– 20
Unit
Qty.
Wt. Lbs.
Per 100
50
13
US: 1-866-764-5454
CAN: 1-800-265-0502
Cat. #
PARC50HD
PARC75HD
PARC100HD
PARC125HD
PARC150HD
PARC200HD
PARC250HD
PARC300HD
PARC350HD
PARC400HD
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
Load
Rating
Lbs
Std.
Pkg.
Wt. Lbs.
Per 100
30
50
60
75
80
100
125
165
200
330
50
50
50
25
25
25
25
10
10
10
50
53
60
70
82
132
192
194
216
232
• Conduit Clamps
• Conduit Reducers
Rigid/Intermediate
Grade Conduit Fittings
CONDUIT REDUCERS – STEEL/FERALOY®
CONDUIT CLAMPS
Applications:
• Edge Type – to attach the conduit run at a 90° angle to a thin beam
or structural member
Edge Type – Electrogalvanized – Iron
Cat. #
Cat. #
ETC50HD
ETC75HD
ETC100HD
ETC125HD
ETC150HD
ETC200HD
ETC250HD
ETC300HD
Trade
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
50
50
50
25
25
25
25
10
63
69
82
95
108
121
153
214
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
JCC Series conduit beam clamps are:
• Available in 1/ 2" to 4" sizes
• Suitable for IMC, EMT and rigid conduit
• Designed to exceed UL load requirements
• Made from ductile iron with an electrogalvanized finish
• Designed to support conduit on vertical or horizontal beams
Conduit Beam Clamp – J Type – Iron
UL File No. E-184283
Cat. #
JCC1
JCC2
JCC34
JCC56
JCC78
JCC910
Size
1/ 2"
3/ 4"
1" & 11/ 4"
11/ 2" & 2"
21/ 2" & 3"
31/ 2" & 4"
Max
Weight
Support
Unit
Qty.
Wt. Lbs.
Per 100
150
150
225
300
500
700
25
25
10
5
2
2
35
43
90
190
380
575
US: 1-866-764-5454
CAN: 1-800-265-0502
Unit
Qty.
Wt. Lbs.
Per 100
251
252
253
3/ 4"
– 1/ 2"
1" – 1/ 2"
11/ 4" – 1/ 2"
50
25
10
4
13
30
254
255
260
11/ 2" – 1/ 2
2" – 1/ 2"
1" – 3/ 4"
10
5
25
43
83
7
261
262
263
11/ 4" – 3/ 4"
11/ 2" – 3/ 4"
2" – 3/ 4"
10
10
5
23
40
79
268
269
270 S
11/ 4" – 1"
11/ 2" – 1"
2" – 1"
10
10
5
18
27
66
275
276
281
11/ 2" – 11/ 4"
2" – 11/ 4"
2" – 11/ 2"
10
5
5
13
24
27
282
283
285
21/ 2" – 1"
21/ 2" – 11/ 4"
21/ 2" – 2"
10
10
10
120
130
150
3" – 11/ 2"
3" – 2"
3" – 21/ 2"
5
2
5
210
160
120
291
292
293
31/ 2" – 2"
31/ 2" – 21/ 2"
31/ 2" – 3"
2
2
2
200
225
150
294
295
296
4" – 2"
4" – 21/ 2"
4" – 3"
2
2
2
270
270
260
297
298
299
4" – 31/ 2"
5" – 4"
6" – 5"
2
1
1
160
385
475
288
289
290M
Copyright© 2007 Cooper Crouse-Hinds
Rigid Intermediate
Features:
Size
113
Rigid/Intermediate
Grade Conduit Fittings
• Heavy-Duty Conduit U-Bolts with Hex Nuts
• Plugs
• Split Conduit Couplings
PLUGS – CAST IRON
SPLIT CONDUIT COUPLINGS
Features:
Recessed
• Concrete Tight
• Suitable for use in Class I, Division 2 Areas
Cat. #
PLG1M
PLG2M
PLG3M
PLG4M
PLG5M
PLG6M
PLG7M
PLG8M
PLG9M
PLG10M
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
Wt. Lbs.
Per 100
50
50
25
25
10
10
2
2
1
1
6
11
22
34
48
82
150
222
340
380
Cat. #
TCC1
TCC2
TCC3
TCC4
TCC5
TCC6
TCC7
TCC8
TCC9
TCC10
TCC12
TCC14
Rigid Intermediate
Square Head
Cat. #
PLG15M
PLG25M
PLG35M
PLG45M
PLG55M
PLG65M
PLG75M
PLG85M
PLG95M
PLG105M
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Body – Ductile Iron
Clamping Hardware – Electrogalvanized Steel
Gasket-Neoprene
Unit
Qty.
Wt. Lbs.
Per 100
50
50
25
25
10
10
1
1
1
1
12
16
25
34
48
80
116
185
232
310
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
HEAVY-DUTY CONDUIT U-BOLTS WITH
HEX NUTS
Electrogalvanized – Iron
Cat. #
UBM50HD
UBM75HD
UBM100HD
UBM125HD
UBM150HD
UBM200HD
UBM250HD
UBM300HD
UBM350HD
UBM400HD
114
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Thread
Size
5/ 16"
– 18
– 18
5/ 16" – 18
5/ 16" – 18
5/ 16" – 18
3/ 8" – 16
3/ 8" – 16
3/ 8" – 16
3/ 8" – 16
3/ 8" – 16
5/ 16"
Unit
Qty.
Wt. Lbs.
Per 100
200
200
100
50
50
50
25
25
20
20
12
14
17
19
21
28
37
42
46
51
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
10
10
10
5
5
5
2
2
1
1
1
1
39
45
68
82
116
111
283
323
395
506
944
1218
• Conduit Hubs
Rigid/Intermediate
Grade Conduit Fittings
IRON SPACE SAVER CONDUIT HUBS
Applications:
MALLEABLE IRON CONDUIT
HUBS
Applications:
• Ideal for terminating electrical conduit through the walls of
enclosures.
• Designed for use indoors or outdoors with rigid conduit and IMC,
specific applications include food processing plants, distilleries,
breweries, sewage disposal plants, chemical plants, paper
processing mills and refineries.
• Ideal for terminating electrical
conduit through the walls of
enclosures.
• Designed for use indoors or
outdoors with rigid conduit and
IMC, specific applications
include food processing plants,
distilleries, breweries, sewage
disposal plants, chemical plants,
paper processing mills and
refineries.
Features:
Features:
Certifications and Compliances:
•
•
•
•
•
•
•
Class I, Division 2 – NEC 501.4 (B)
Class II, Divisions 1 & 2 – NEC 502.4 (A) (B)
Class III, Divisions 1 & 2 – NEC 503.3 (A) (B)
UL Listed – UL Standard 514B
cUL Listed – Certified by UL to CSA Standard C22.2 No. 18
NEMA: FB-1
Suitable for wet locations
Certifications and Compliances:
•
•
•
•
•
•
•
Class I, Division 2 - NEC 501.4(B).
Class II, Divisions 1 & 2 - NEC 502.4(A)(B).
Class III, Division 1 & 2 - NEC 503.3(A)(B).
UL Listed - UL Standard 514B.
cUL Listed - Certified by UL to CSA Standard C22.2 No. 18.
NEMA: FB-1
Suitable for wet locations.
Rigid Intermediate
• Male thread type
• Tapered female thread for rigid conduit and IMC
• Recessed O-ring gasket assures raintight and dust tight
connections
• Insulated throat provides smooth pulling surface
• Locking screw on the nut doubles as a grounding screw for added
safety
• Complete size range from 1/ 2" to 6"
• Hubs fit standard knockouts. No special tools required
• Male thread is on the nut for
space saving.
• Quick and easy when installing
rigid conduit nipple between two
existing enclosures.
• Insulated throat provides smooth
pulling surface.
• Furnished with SG sealing gasket.
• Hub fits standard knockouts. No
special tools required.
Standard Materials & Finishes:
• Material: Malleable Iron
• Finish: Zinc Electroplate
Dimensions
In Inches:
Cat. #
MHUB1
MHUB2
MHUB3
MHUB4
MHUB5
MHUB6
MHUB7
MHUB8
MHUB9
MHUB10
MHUB11
MHUB12
Trade Size
Unit Qty.
Std. Pkg.
Wt. Lbs. Per 100
1/ 2"
25
25
5
5
2
1
1
1
1
1
1
1
100
100
50
25
20
10
10
5
5
2
1
1
18
25
50
25
20
10
10
5
5
2
1
1
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
Cat. #
HUB1
HUB2
HUB3
HUB4
HUB5
HUB6
HUB7
HUB8
HUB9
HUB10
Note:
US: 1-866-764-5454
CAN: 1-800-265-0502
Conduit
Size
Unit
Qty.
Wt. Lbs.
Per 100
a
b
c
1/ 2
25
10
5
5
2
1
1
1
1
1
18
25
50
25
20
10
10
5
5
2
1
11/ 8
13/ 8
11/ 2
15/ 8
111/ 16
23/ 16
27/ 16
27/ 16
29/ 16
11/ 4
19/ 16
17/ 8
25/ 16
21/ 2
3
35/ 8
41/ 4
43/ 4
51/ 4
1
13/ 8
15/ 8
2
23/ 8
213/ 16
37/ 16
41/ 16
411/ 16
51/ 16
3/ 4
1
11/ 4
11/ 2
2
21/ 2
3
31/ 2
4
d
x
1/ 8 9/ 64
5/ 32 1/ 4
3/ 16 9/ 32
1/ 4 7/ 16
1/ 4 7/ 16
1/ 4 7/ 16
1/ 4 7/ 16
1/ 4 7/ 16
5/ 16 3/ 4
5/ 16 11/ 8
Dimension "x" is maximum wall thickness of box that will meet the requirement for
three full threads engagement of nipple and fitting body when box connector or rigid
conduit hub is installed in a knockout or slip hole.
Copyright© 2007 Cooper Crouse-Hinds
115
•
•
•
•
Series 5 Combination Conduit
Outlet Bodies For EMT
and IMC or Rigid Conduit
EMT CONDUIT OUTLET BODIES – CAST
ALUMINUM†
Combination Conduit Outlet Bodies
Die Cast Aluminum
Available in SnapPack™
Stainless Steel Cover Screws
Type T
UL File No. E-15022
Applications:
Die cast aluminium Series 5 Conduit Bodies are used in conduit
systems to:
• Act as pull outlets for conductors being installed
• Provide openings for making splices and taps in conductors
• Act as mounting outlets for lighting fixtures and wiring devices
• Connect conduit sections
• Provide taps for branch conduit runs
• Make 90 degree bends in conduit runs
• Provide for access to conductors for maintenance and future system
changes
• EMT Conduit bodies are supplied with threaded hubs for use with
IMC or Rigid conduit and set screws for use with EMT conduit
Cat. #
T15
T25
T35
T45
T55
T65
Trade
Size
MT
MT
MT
MT
MT
MT
Trade
Size
Outlet Bodies
Cat. #
C15
C25
C35
C45
C55
C65
MT
MT
MT
MT
MT
MT
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
33.5
33.5
69.5
10
10
5
2
2
1
100
50
25
10
10
5
27
40
64
165
150
270
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 1/0 AWAG
3 # 4/0 AWG
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
33.1
33.1
67.0
10
10
5
2
2
1
100
50
25
10
10
5
27
40
64
165
150
270
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 1/0 AWAG
3 # 4/0 AWG
3/ 4"
1"
11/ 4"
11/ 2"
2"
Type LB
Cat. #
Type C
Unit
Qty.
1/ 2"
Standard Materials:
• Copper Free Aluminum‡
Internal
Vol. in
Cu. In.
LB15 MT
LB25 MT
LB35 MT
LB45 MT
LB55 MT
LB65 MT
LB75 MT*
LB85 MT*
LB95 MT*
LB105 MT*
Trade
Size
Internal
Vol. in
Cu. In.
Unit
Qty.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.0
32.3
33.8
71.2
71.2
183.5
304.9
308.0
10
10
5
2
2
1
1
1
1
1
27
40
56
132
175
240
450
460
800
900
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 2 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 400 MCM
3 # 400 MCM
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
*Fittings greater than 2" are set-screw only (not combination threaded &
set-screw)
Covers, Aluminum
Type LL
Trade
Size
Cat. #
LL15
LL25
LL35
LL45
LL55
LL65
MT
MT
MT
MT
MT
MT
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Cat. #
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
35.8
35.8
69.7
10
10
5
2
2
1
100
50
25
10
10
5
27
40
64
165
150
270
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 1/0 AWAG
3 # 4/0 AWG
LR15
LR25
LR35
LR45
LR55
LR65
Trade
Size
116
MT
MT
MT
MT
MT
MT
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
1/ 2"
50
50
50
50
25
10
5
250
250
250
50
25
10
5
5
6
20
25
25
78
140
3/ 4"
1"
11/ 4" – 11/ 2"
2"
21/ 2" – 3"
31/ 2" – 4"
Gaskets, Neoprene
Type LR
Cat. #
150
250
350
450
650
850D
950D
Conduit
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Cat. #
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
35.8
35.8
69.7
10
10
5
2
2
1
100
50
25
10
10
5
27
40
64
165
150
270
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 1/0 AWAG
3 # 4/0 AWG
US: 1-866-764-5454
CAN: 1-800-265-0502
GASK015N
GASK025N
GASK035N
GASK045N
GASK065N
GASK085N
GASK095N
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
1/ 2"
100
100
50
50
25
10
10
100
100
50
50
25
10
10
2
2
3
6
10
20
30
3/ 4"
1"
11/ 4" – 11/ 2"
2"
21/ 2" – 3"
31/ 2" – 4"
†SnapPack™ EMT conduit bodies consisting of body, cover and gasket assembled and
shipped together, change "-MT" to "-MTC" in catalog number i.e.: LB25-MTC
‡Percentage of copper in conduit bodies is 0.1% min and 0.25 % max
Copyright© 2007 Cooper Crouse-Hinds
• Rigid Conduit Outlet Bodies
• Die Cast Aluminum
• Available in SnapPack™†
Series 5 Conduit Outlet
Bodies For Rigid/IMC Conduit
RIGID CONDUIT OUTLET BODIES – CAST
ALUMINUM
Standard Materials:
Type T †
• Copper Free Aluminum‡
Options:
Cat. #
Description
†SnapPack™ pre-packaged body, cover and neoprene gasket
ie. LB25-CGN
Suffix
CGN
Type C †
Cat. #
C15
C25
C35
C45
C55
C65
C75
C85
C95*
C105*
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
33.5
33.5
69.5
69.5
188.0
307.0
309.0
10
10
5
2
2
1
1
1
1
1
100
50
25
10
10
5
1
1
1
1
27
40
64
165
150
270
500
600
900
1000
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 2 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 400 MCM
3 # 400 MCM
*Not UL Listed
Cat. #
LL15
LL25
LL35
LL45
LL55
LL65
LL75
LL85
LL95
LL105
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
35.8
35.8
69.7
69.7
186.0
306.0
308.0
10
10
5
2
2
1
1
1
1
1
100
50
25
10
10
5
1
1
1
1
30
48
64
140
160
270
500
600
900
1000
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 1/0 AWAG
3 # 4/0 AWG
3 # 300 MCM
3 # 350 MCM
3 # 350 MCM
3 # 350 MCM
Type LR †
Cat. #
LR15
LR25
LR35
LR45
LR55
LR65
LR75
LR85
LR95
LR105
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
33.1
33.1
67.0
67.0
175.0
298.0
300.0
10
10
5
2
2
1
1
1
1
1
100
50
25
10
10
2
1
1
1
1
32
46
70
175
185
300
550
650
950
1050
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 2 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 400 MCM
3 # 400 MCM
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.25
7.3
12.0
32.3
33.8
71.2
71.2
183.5
304.9
308.0
10
10
5
2
2
1
1
1
1
1
100
50
25
10
10
5
1
1
1
1
27
40
56
132
175
240
450
460
800
900
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 2 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 4/0 AWG
3 # 400 MCM
3 # 400 MCM
*Not UL Listed
Type LB †
Cat. #
LB15
LB25
LB35
LB45
LB55
LB65
LB75
LB85
LB95
LB105
Trade
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Covers, Aluminum
Cat. #
150
250
350
450
650
850D
950D
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
1/ 2"
50
50
50
50
25
10
5
250
250
250
50
25
10
5
5
6
20
25
25
78
140
3/ 4"
1"
11/ 4" – 11/ 2"
2"
21/ 2" – 3"
31/ 2" – 4"
Gaskets, Neoprene
Internal
Vol. in
Cu. In.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Max. # of
Conductors
4.35
7.3
12.2
35.8
35.8
69.7
69.7
186.0
306.0
308.0
10
10
5
2
2
1
1
1
1
1
100
50
25
10
10
5
1
1
1
1
26
48
64
140
160
260
500
600
900
1000
NA
3 # 6 AWG
3 # 4 AWG
3 # 2 AWG
3 # 1/0 AWAG
3 # 4/0 AWG
3 # 300 MCM
3 # 350 MCM
3 # 350 MCM
3 # 350 MCM
US: 1-866-764-5454
CAN: 1-800-265-0502
Cat. #
GASK015N
GASK025N
GASK035N
GASK045N
GASK065N
GASK085N
GASK095N
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
1/ 2"
100
100
50
50
25
10
10
100
100
50
50
25
10
10
2
2
3
6
10
20
30
3/ 4"
1"
11/ 4" – 11/ 2"
2"
21/ 2" – 3"
31/ 2" – 4"
‡Percentage of copper in conduit bodies is 0.1% min and 0.25 % max
Copyright© 2007 Cooper Crouse-Hinds
117
Outlet Bodies
Type LL †
T15
T25
T35
T45
T55
T65
T75
T85
T95*
T105*
Trade
Size
• Rigid and combination Rigid or IMC and EMT
Conduit Outlet Bodies
• Die Cast Aluminum
Conduit Outlet Bodies
Series 5
Dimensions
Type LB Dimensions – Threaded & Set Screw
Conduit
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
A
B
C
D
E
F
111/ 32"
135/ 64"
13/ 4"
235/ 64"
219/ 32"
313/ 64"
41/ 2"
415/ 32"
539/ 64"
539/ 64"
157/ 64"
449/ 64"
53/ 8"
715/ 64"
717/ 64"
933/ 64"
123/ 16"
1217/ 64"
51/ 32"
151/ 32"
1/ 2"
211/ 64"
27/ 16"
23/ 4"
335/ 64"
323/ 32"
41/ 4"
55/ 32"
521/ 32"
661/ 64"
661/ 64"
413/ 32"
51/ 8"
515/ 16"
77/ 8"
77/ 8"
1015/ 64"
123/ 4"
1243/ 64"
1535/ 64"
1535/ 64"
15/ 32"
13/ 8"
123/ 32"
215/ 64"
23/ 8"
229/ 32"
313/ 32"
41/ 64"
55/ 32"
55/ 32"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Type C Dimensions – Threaded & Set Screw
Conduit
Size
1/ 2"
Outlet Bodies
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
A
B
C
D
E
F
15/ 16"
117/ 32"
13/ 4"
217/ 32"
217/ 32"
27/ 32"
41/ 2"
41/ 2"
51/ 2"
51/ 2"
327/ 32"
419/ 32"
511/ 32
71/ 4"
71/ 4"
97/ 16"
121/ 4"
121/ 4"
15"
15"
1/ 2"
11/ 2"
15/ 8"
129/ 32"
23/ 4"
23/ 4"
313/ 32"
41/ 2"
41/ 2"
59/ 16"
59/ 16"
427/ 32"
541/ 64"
61/ 2"
81/ 2"
81/ 2"
103/ 4"
13"
13"
165/ 16"
165/ 16"
11/ 8"
15/ 16"
11/ 2"
21/ 4"
21/ 4"
23/ 4"
41/ 2"
41/ 2"
51/ 2"
51/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Type LL Dimensions – Threaded & Set Screw
Conduit
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
118
A
B
C
D
E
F
13/ 32"
37/ 8"
1/ 2"
2"
211/ 32"
21/ 2"
313/ 32"
313/ 32"
327/ 32"
53/ 4"
53/ 4"
61/ 8"
61/ 8"
49/ 32"
113/ 32"
11/ 4"
11/ 2"
21/ 4"
21/ 4"
23/ 4"
45/ 8"
45/ 8"
57/ 16"
57/ 16"
421/ 32"
523/ 64"
717/ 64"
717/ 64"
915/ 32"
121/ 4"
121/ 4"
15"
15"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
US: 1-866-764-5454
CAN: 1-800-265-0502
51/ 8"
599/ 64"
755/ 64"
755/ 64"
1013/ 64"
13"
13"
165/ 16"
165/ 16"
113/ 32"
17/ 8"
27/ 8"
27/ 8"
327/ 64"
41/ 2"
41/ 2"
59/ 16"
59/ 16"
Copyright© 2007 Cooper Crouse-Hinds
• Rigid and combination Rigid or IMC and EMT
Conduit Outlet Bodies
• Die Cast Aluminum
Conduit Outlet Bodies
Series 5
Dimensions
Type LR Dimensions – Threaded & Set Screw
Conduit
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
A
B
C
D
E
F
17/ 64"
11/ 4"
11/ 2"
21/ 4"
21/ 4"
23/ 4"
47/ 16"
45/ 8"
57/ 16"
57/ 16"
37/ 8"
421/ 32"
523/ 64"
717/ 64"
717/ 64"
915/ 32"
121/ 4"
121/ 4"
15"
15"
1/ 2"
2"
211/ 32"
21/ 2"
313/ 32"
313/ 32"
327/ 32"
513/ 16"
513/ 16"
61/ 8"
61/ 8"
49/ 32"
51/ 8"
559/ 64"
755/ 64"
755/ 64"
1013/ 64"
121/ 4"
121/ 4"
15"
15"
113/ 32"
141/ 64"
17/ 8"
27/ 8"
27/ 8"
327/ 64"
41/ 2"
41/ 2"
61/ 4"
61/ 4"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Type T Dimensions – Threaded & Set Screw
Conduit
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
A
B
C
D
E
F
15/ 16"
117/ 16"
125/ 32"
21/ 2"
21/ 2"
31/ 4"
41/ 2"
41/ 2"
51/ 2"
51/ 2"
327/ 32"
439/ 64"
53/ 8"
71/ 4"
71/ 4"
97/ 16"
121/ 4"
121/ 4"
15"
15"
1/ 2"
13/ 8"
141/ 64"
129/ 32"
23/ 4"
23/ 4"
327/ 64"
41/ 2"
41/ 2"
59/ 16"
59/ 16"
427/ 32"
519/ 32"
61/ 2"
81/ 2"
81/ 2"
1013/ 16"
13"
13"
165/ 16"
165/ 16"
21/ 16"
211/ 32"
219/ 32"
335/ 64"
335/ 64"
43/ 64"
525/ 32"
525/ 32"
613/ 16"
613/ 16"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Outlet Bodies
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
119
Conduit Outlet Bodies
Form 5
•
•
•
•
•
Rigid Conduit Outlet Bodies
Malleable Iron
Stainless Steel Cover Screws
Integral Gasket Covers
Available in SnapPack™†
Applications:
Standard Materials:
Form 5 Malleable Iron Conduit Bodies are used in conduit systems to:
• Act as pull outlets for conductors being installed
• Provide openings for making splices and taps in conductors
• Act as mounting outlets for lighting fixtures and wiring devices
• Connect conduit sections
• Provide taps for branch conduit runs
• Make 90 degree bends in conduit runs
• Provide for access to conductors for maintenance and future system
changes
•
•
•
•
Features:
Standard Finishes:
•
•
•
•
Malleable iron – electrogalvanized and aluminum acrylic paint
Neoprene – natural
Sheet steel – electrogalvanized
Stainless steel – natural
Certifications and Compliances:
• UL Standard 514B
• cUL to CSA Standard C22.2 No. 18
Outlet Bodies
• Interchangeable with Appleton Form 35 Conduit Bodies
• Built–in rollers on 11/ 4" to 4" C and LB bodies to facilitate wire pulling
• Smooth and rounded integral bushings for protection of wire
insulation
• Solid neoprene gaskets may be converted to open type by pulling
out perforated center section
• Stainless steel cover screws
• Domed sheet steel covers provide additional cubic capacity
• Integral gasket cover provides NEMA 4 rating
Bodies – Malleable iron
Gaskets – Neoprene
Covers – sheet steel or malleable
Cover screws – stainless steel
Form 35 is a registered trademark of Appleton Electric/EGS.
120
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
• Rigid Conduit Outlet Bodies
• Malleable Iron
Conduit Outlet Bodies
Form 5
Options:
Type LR ‡
Description
‡Snapack™ -packaged body, cover and neoprene gasket
Available on all sizes
Suffix
CG
Type LB ‡
Cat.#
Internal
Vol. in
Size Cu. In.
Cat.#
LB50M
LB75M
LB100M
LB125M*
LB150M*
LB200M*
LB250M*
LB300M*
LB350M*
LB400M*
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Internal
Vol. in
Size Cu. In.
4.5
7.5
12.5
32.0
35.3
73.0
142.0
173.0
292.0
324.0
Wt.
Unit
Lbs.
Qty. Per 100
10
10
10
5
5
1
1
1
1
1
71
97
143
287
331
534
1105
1160
1989
2099
Max. # of
Conductors
3
3
3
3
N/A
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #2 XHHW MAX.
3 #1/0 XHHW MAX.
3 #4/0 XHHW MAX.
#300 MCM XHHW MAX.
#400 MCM XHHW MAX.
#500 MCM XHHW MAX.
#500 MCM XHHW MAX.
LR50M
LR75M
LR100M
LR125M
LR150M
LR200M
LR250M
LR300M
LR350M
LR400M
1/ 2"
LL50M
LL75M
LL100M
LL125M
LL150M
LL200M
LL250M
LL300M
LL350M
LL400M
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
4.5
7.5
12.5
32.0
33.0
68.0
142.0
173.0
292.0
324.0
10
10
10
5
5
1
1
1
1
1
76
95
138
309
332
497
1105
1437
2321
2431
Max. # of
Conductors
3
3
3
3
N/A
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #2 XHHW MAX.
3 #2 XHHW MAX.
3 #4/0 XHHW MAX.
#300 MCM XHHW MAX.
#350 MCM XHHW MAX.
#350 MCM XHHW MAX.
#350 MCM XHHW MAX.
T50M
T75M
T100M
T125M
T150M
T200M
T250M
T300M
T350M
T400M
Size
Cat.#
C50M
C75M
C100M
C125M*
C150M*
C200M*
C250M*
C300M*
C350M*
C400M*
Internal
Vol. in
Size Cu. In.
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
4.5
7.5
12.5
35.0
35.3
75.0
153.0
181.0
290.0
320.0
Wt.
Unit
Lbs.
Qty. Per 100
10
10
10
5
5
1
1
1
1
1
98
118
170
309
368
552
1216
1437
2210
2321
Max. # of
Conductors
3
3
3
3
N/A
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #2 XHHW MAX.
3 #1/0 XHHW MAX.
3 #4/0 XHHW MAX.
#300 MCM XHHW MAX.
#300 MCM XHHW MAX.
#350 MCM XHHW MAX.
#350 MCM XHHW MAX.
*1 1/ 4" – 4" LB and C Bodies supplied with built in rollers to facilitate wire pulling.
US: 1-866-764-5454
CAN: 1-800-265-0502
Unit
Qty.
Wt.
Lbs.
Per 100
6.0
9.5
15.0
33.0
36.0
76.0
142.0
173.0
292.0
324.0
10
10
10
5
5
1
1
1
1
1
111
137
196
332
368
663
1271
1547
2542
2542
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
3
3
3
3
N/A
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #2 XHHW MAX.
3 #2 XHHW MAX.
3 #4/0 XHHW MAX.
#300 MCM XHHW MAX.
#350 MCM XHHW MAX.
#350 MCM XHHW MAX.
#350 MCM XHHW MAX.
Max. # of
Conductors
3
3
3
3
N/A
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #2 XHHW MAX.
3 #1 XHHW MAX.
3 #2/0 XHHW MAX.
#300 MCM XHHW MAX.
#300 MCM XHHW MAX.
#350 MCM XHHW MAX.
#350 MCM XHHW MAX.
Type TB ‡
Cat.#
Type C ‡
Internal
Vol. in
Cu. In.
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
71
100
157
332
345
626
1105
1437
2321
2500
Size
1/ 2"
TB50M
TB75M
TB100M
TB125M
TB150M
TB200M
3/ 4"
1"
11/ 4"
11/ 2"
2"
Internal
Vol. in
Cu. In.
Unit
Qty.
Wt.
Lbs.
Per 100
Max. # of
Conductors
6.0
9.5
15.0
33.0
36.0
76.0
10
10
10
5
5
1
88
120
197
342
420
691
N/A
3 #6 AWG MAX.
3 #6 AWG MAX.
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #1/0 XHHW MAX.
Type X ‡
Cat.#
X50M
X75M
X100M
X125M
X150M
X200M
Size
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Internal
Vol. in
Cu. In.
Unit
Qty.
Wt.
Lbs.
Per 100
Max. # of
Conductors
6.0
9.5
15.0
33.0
36.0
76.0
10
10
10
5
5
1
139
172
247
416
463
833
N/A
3 #6 AWG MAX.
3 #4 XHHW MAX.
3 #2 XHHW MAX.
3 #1/0 XHHW MAX.
3 #2/0 XHHW MAX.
Copyright© 2007 Cooper Crouse-Hinds
121
Outlet Bodies
Cat.#
Wt.
Unit
Lbs.
Qty. Per 100
10
10
10
5
5
1
1
1
1
1
Max. # of
Conductors
Type T ‡
Cat.#
Internal
Vol. in
Size Cu. In.
4.5
7.5
12.5
32.0
35.3
68.0
142.0
173.0
292.0
324.0
3/ 4"
*1 1/ 4" – 4" LB and C Bodies supplied with built in rollers to facilitate wire pulling.
Type LL ‡
Wt.
Unit
Lbs.
Qty. Per 100
• Rigid Conduit Outlet Bodies
• Malleable Iron
Conduit Outlet Bodies
Form 5
Sheet Steel Covers
Neoprene Gaskets with perforated Center
Cat. #
Size
K50S
K75S
K100S
K125S
K200S
K250S
K350S
1/ 2"
3/ 4"
1"
& 11/ 2"
2"
21/ 2" & 3"
31/ 2" & 4"
11/ 4"
Unit
Qty.
Wt. Lbs.
Per 100
50
50
25
20
5
5
5
9
13
19
31
50
94
138
1/ 2"
GK50N
GK75N
GK100N
GK125N
GK200N
GK250N
GK350N
3/ 4"
1"
11/ 4" & 11/ 2"
2"
21/ 2" & 3"
31/ 2" & 4"
Size
1/ 2"
3/ 4"
1"
& 11/ 2"
2"
21/ 2" & 3"
31/ 2" & 4"
11/ 4"
Unit
Qty.
Wt. Lbs.
Per 100
50
50
25
20
5
5
5
23
31
41
91
208
358
550
Cat. #
K50SG
K75SG
K100SG
K125SG
K200SG
K250SG
K350SG
Size
1/ 2"
3/ 4"
1"
11/ 4" & 11/ 2"
2"
21/ 2" & 3"
31/ 2" & 4"
Outlet Bodies
K50CM
K75CM
K100CM
K125CM
K200CM
K250CM
K350CM
122
Unit
Qty.
Size
100
100
50
25
25
25
25
Sheet Steel Cover with Integral Gasket
Cast Iron Covers
Cat. #
Cat. #
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Unit
Qty.
Wt. Lbs.
Per 100
50
50
25
20
5
5
5
14
16
46
62
70
190
340
• Rigid Conduit Outlet Bodies
• Malleable Iron
Conduit Outlet Bodies
Form 5
Dimensions
Dimensions In Inches:
Form 5 Iron LB
Size
A
B
C
1/ 2
3/ 4
1
11/4
11/2
2
21/2
3
31/2
4
1.34
4.68
2.05
1.50
5.37
2.25
1.80
6.20
2.65
2.60
8.12
2.75
2.60
8.12
2.83
3.12
10.50
4.42
4.31
13.60
5.40
4.31
13.87
5.90
5.62
16.25
6.90
5.62
16.60
7.21
1/ 2
3/ 4
1
11/4
11/2
2
21/2
3
31/2
4
2.05
4.68
1.37
2.25
5.37
1.70
2.65
6.20
1.90
2.75
8.12
2.75
3.50
8.12
2.83
4.12
10.50
3.31
5.71
13.60
3.90
5.87
13.87
4.75
7.13
16.50
6.81
7.13
16.50
7.19
1/ 2
3/ 4
1
11/4
11/2
2
21/2
3
31/2
4
2.05
4.68
1.37
2.25
5.37
1.70
2.65
6.20
1.90
2.75
8.12
2.75
3.50
8.12
2.83
4.12
10.50
3.31
5.71
13.60
3.90
5.87
13.87
4.75
6.10
6.25
5.62
6.95
16.25
5.62
1/ 2
3/ 4
1
11/4
11/2
2
21/2
3
31/2
4
1.34
5.38
1.37
1.50
6.00
1.70
1.80
7.05
1.90
2.60
9.00
2.75
2.60
9.00
2.83
3.12
11.50
3.31
4.31
15.00
3.90
4.31
15.12
4.75
4.88
18.13
5.19
4.88
18.13
5.56
1/ 2
3/ 4
1
11/4
11/2
2
21/2
3
31/2
4
2.05
5.38
1.34
2.25
6.00
1.50
2.65
7.05
1.80
2.75
9.00
2.60
3.50
9.00
2.60
4.12
11.50
3.12
5.71
15.00
4.31
5.87
15.12
4.31
6.81
18.13
5.19
7.15
18.13
5.56
Form 5 Iron LL
Conduit
A
B
C
Form 5 Iron LR
Conduit
A
B
C
Form 5 Iron C
A
B
C
Outlet Bodies
Conduit
Form 5 Iron T
Conduit
A
B
C
Form 5 Iron TB
Conduit
A
B
C
1/ 2
3/ 4
1
11/4
11/2
2
1.34
5.38
2.05
1.50
6.00
2.25
1.80
7.05
2.65
2.60
9.00
2.75
2.60
9.00
2.83
3.12
11.50
4.42
1/ 2
3/ 4
1
11/4
11/2
2
2.79
5.41
1.75
2.93
6.08
1.97
3.56
7.1
2.25
4.43
9.1
2.55
4.43
9.1
2.75
5.4
11.75
3.45
Form 5 Type X
Conduit
A
B
C
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
123
Sealing Locknuts
Applications
UL File No. E-19189
Only one Sealing Locknut is required to:
• Functionally replace rigid threaded
enclosure connectors.
• Provide raintight, watertight, or oiltight
seal in any position.
• Provide positive ground connection.
• Provide economies in installation and
fitting costs.
Features And Benefits:
Sealing Locknuts
• Integrally fused PVC gasket provides
positive seal against water, oils and other
liquids.
• Designed for use with raintight, watertight
and oiltight enclosures, NEMA 2, 3, 3R, 4
and 12.
• UL Listed Raintight.
• UL Listed Liquidtight.
• Can be used with either sheet metal or
standard cast metal boxes.
• CSA Certified watertight.
• 1/ 2" – 2" Heavy-duty steel.
• 21/ 2" – 6" Malleable iron.
• U.S. Patent #4022262
124
Cat. #
Size
SL1
SL2
SL3
SL4
SL5
SL6
SL7
SL8
SL9
SL10
SL11
SL12
1/ 2"
US: 1-866-764-5454
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
CAN: 1-800-265-0502
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
100
50
25
25
25
25
10
10
10
5
2
1
100
500
250
250
100
100
50
50
50
25
2
1
1
2
4
4
5
8
28
38
46
52
125
140
Copyright© 2007 Cooper Crouse-Hinds
• Liquidator™ Liquidtight Flexible Metallic Conduit
Fittings
Liquidtight Conduit Fittings
Features and Benefits:
UL File No. E-19189
Applications:
Certifications and Compliances:
• NEC/CEC:
Class I, Division 2
Class II, Divisions 1 and 2
Class III, Divisions 1 and 2
• UL Standards: 514B, 467
• CSA Standard: C22.2 No. 18
US: 1-866-764-5454
CAN: 1-800-265-0502
Standard Materials:
• Body – Straight: 3/ 8" through 6" – malleable iron or aluminum
45° and 90°; 3/ 8" through 4" – malleable iron or aluminum
• Gland nut – malleable iron or aluminum
• Ferrule – 3/ 8" through 6" – steel
• Gland nut sealing ring – polyethylene
• Sealing gasket – thermoplastic elastomer
• Locknut – steel
Standard Finishes:
• Malleable iron – zinc electroplate
• Polyethylene, thermoplastic elastomer, aluminum and die cast –
natural
User Benefits:
• Assurance of safe and reliable performance. End user peace of
mind.
• Meets NEC and UL requirements for use in wet locations. Reduces
downtime and replacement costs.
• Complete selection of styles and sizes. Easy selection from one
source, saves time and money.
• High strength and excellent corrosion resistance. Long service life,
eliminates the need for replacement.
• Provides excellent pullout strength and grounding for safety of
personnel and equipment.
• Easy to install. Cannot be installed incorrectly. Saves labor.
• Eliminates leakage, potential downtime and replacement costs.
Protection against vibration.
• Can be disassembled and reused. Cost savings.
• Easy wrenching, Fast, easy installation results in labor savings.
• Eliminates leakage, potential downtime and replacement costs.
• Provides a reliable ground and safety of personnel and equipment.
Won’t vibrate loose.
• One-stop source to meet user needs. Saves time and money.
Copyright© 2007 Cooper Crouse-Hinds
125
Liquidtight
Typical applications for liquidtight conduit and the Liquidator include
the wiring of machine tools… motors… transformers… food
processing equipment… robotics… air conditioning units… illuminated
store front signs and billboards… etc. The flexible metallic conduit and
fittings protect conductors from mechanical damage due to vibration
and movement and seals out cutting oils, coolants, water, dust, etc.
Applications such as these can be found in, but are not limited to,
industries such as:
• Machine tool manufacturers.
• Electric power generating plants.
• Waste treatment facilities.
• Paint manufacturing facilities.
• Automobile manufacturing facilities.
• Aerospace industries.
• Breweries.
• Food processing plants.
• Dairies.
• Pulp and paper mills.
• Petroleum refineries.
• Chemical and petrochemical plants.
• UL and cUL Listed.
• Provided protection in wet locations.
• Straight available in 3/ 8" through 6" sizes; 45° and 90° available in
3/ 8" through 4" sizes.
• Malleable iron bodies and gland nuts with zinc electroplate; steel
ferrules and locknuts with zinc electroplate.
• Cupped grounding ferrule is distortion-free and reusable.
• Split polyethylene sealing ring is reversible.
• Grooves inside sealing ring. Jacket of liquidtight conduit will cold
flow into grooves.
• Reusable design.
• Hex surfaces on gland nut and body.
• Thermoplastic elastomer sealing gasket effectively seals out oil,
dust and dirt.
• Steel locknut bites into box.
• Available with or without insulated throats.
• Insulated throat versions, 105°C rated nylon.
• Liquidator™ Liquidtight Flexible Metallic Conduit
Fittings
Liquidtight Conduit Fittings
Straight Connectors – Non-Insulated – Malleable
Iron
Cat. #
LT38
LT50
LT75
LT100
LT125
LT150
LT200
LT250
LT300
LT350
LT400
LT500†
LT600†
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
25
5
5
2
1
1
1
1
1
1
1
100
100
100
50
25
20
10
5
5
5
5
1
1
18
20
26
45
69
85
120
340
430
510
600
800
1075
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
†Not UL Listed or CSA Certified
Straight Connectors – Insulated – Malleable Iron
Liquidtight
Cat. #
LTB38
LTB50
LTB75
LTB100
LTB125
LTB150
LTB200
LTB250
LTB300
LTB350
LTB400
LTB500†
LTB600†
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
25
5
5
2
1
1
1
1
1
1
1
100
100
100
50
25
20
10
5
5
5
5
1
1
18
20
26
45
69
86
120
340
430
510
600
800
1075
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
†Not UL Listed or CSA certified
Straight Connectors – Non-Insulated – Aluminum
Cat. #
LT38 SA
LT50 SA
LT75 SA
LT100 SA
LT125 SA
LT150 SA
LT200 SA
LT250 SA
LT300 SA
LT350 SA
LT400 SA
126
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
25
10
5
2
1
1
1
1
1
100
100
100
50
25
20
10
5
5
5
5
12
12
14
28
34
48
54
121
174
245
279
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
US: 1-866-764-5454
CAN: 1-800-265-0502
45° Angle Connectors — Non-Insulated – Malleable
Iron
Cat. #
LT3845
LT5045
LT7545
LT10045
LT12545
LT15045
LT20045
LT25045
LT30045
LT35045
LT40045
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
27
29
41
70
93
137
199
600
925
1150
1450
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
45° Angle Connectors – Insulated – Malleable Iron
Cat. #
LTB3845
LTB5045
LTB7545
LTB10045
LTB12545
LTB15045
LTB20045
LTB25045
LTB30045
LTB35045
LTB40045
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
27
29
41
70
93
137
195
600
925
1150
1450
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
90° Angle Connectors – Non-Insulated – Malleable
Iron
Cat. #
LT3890
LT5090
LT7590
LT10090
LT12590
LT15090
LT20090
LT25090
LT30090
LT35090
LT40090
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
31
33
48
76
112
155
230
900
1383
1875
2325
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
• Liquidator™ Liquidtight Flexible Metallic Conduit
Fittings
• Zinc Die Cast Liquidtight Fittings
Liquidtight Conduit Fittings
90° Angle Connectors – Insulated – Malleable Iron
SELF RETAINING PVC GASKET WITH
STEEL RING
UL File no. E-22133
Cat. #
LTB3890
LTB5090
LTB7590
LTB10090
LTB12590
LTB15090
LTB20090
LTB25090
LTB30090
LTB35090
LTB40090
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
30
33
48
76
112
155
230
900
1380
1825
2325
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
90° Angle Connectors – Non-Insulated – Aluminum
Cat. #
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
10
10
5
2
1
100
100
50
50
25
10
5
19
18
24
40
48
61
86
LT3890 SA
LT5090 SA
LT7590 SA
LT10090 SA
LT12590 SA
LT15090 SA
LT20090 SA
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
SG1
SG2
SG3
SG4
SG5
SG6
SG7
SG8
SG9
SG10
SG11
SG12
Conduit
Size
Unit
Qty.
Wt. Lbs.
Per 100
3/ 8"
100
50
50
25
25
25
10
10
10
10
5
5
1
2
2
2
4
3
5
10
12
10
15
22
– 1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
ZINC DIE CAST LIQUIDTIGHT
FITTING
Applications:
To terminate and seal liquidtight flexible metal conduit to oiltight,
liquidtight, or raintight box or enclosure. Connectors can be used with
tapered thread female entry or unthreaded knockout using the
provided sealing washer and lock nut.
Features:
• Furnished with lock nut and sealing ring
• Liquidtight/Raintight/Oiltight
• Suitable for wet locations
Liquidtight
Combination Couplings For Coupling Liquidtight To
Threaded RIGID/IMC Conduit
Cat. #
Standard Materials:
• Zinc Die Cast
Standard Finishes:
• Natural
Cat. #
LTR38*
LTR50
LTR75
LTR100
LTR125
LTR150
LTR200
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
25
25
25
5
2
2
1
100
100
100
50
20
20
10
17
29
33
59
105
105
160
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
*For 3/ 8" Liquidtight to 1/ 2" Rigid/IMC
Straight Connectors – Non-Insulated
Cat. #
LT38DC
LT50DC
LT75DC
LT100DC
LT125DC
LT150DC
LT200DC
LT250DC
LT300DC
LT350DC
LT400DC
US: 1-866-764-5454
CAN: 1-800-265-0502
Conduit
Size
Unit
Qty.
Std.
Pkg.
A
B
C
D
3/ 8"
25
25
15
8
5
4
2
1
1
1
1
250
250
150
80
50
40
20
10
10
6
6
1.07
1.07
1.07
1.34
1.15
1.52
1.54
2.20
2.22
2.36
2.44
.96
1.08
1.33
1.56
1.94
2.19
2.66
3.28
3.80
4.28
4.78
.62
.62
.82
1.02
1.36
1.60
2.07
2.51
3.13
3.58
4.05
.47
.47
.47
.57
.71
.71
.71
1.06
1.06
1.06
1.06
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
127
• Zinc Die Cast Liquidtight Fittings
• Grounding Type Liquidtight Flexible Metallic
Conduit Fittings
Liquidtight Conduit Fittings
LIQUIDATOR™ LIQUIDTIGHT FLEXIBLE
METALLIC CONDUIT FITTINGS WITH
GROUND LUG
Straight Connectors – Insulated
For Liquidtight Flexible Steel Conduit
Cat. #
LTB38DC
LTB50DC
LTB75DC
LTB100DC
LTB125DC
LTB150DC
LTB200DC
LTB250DC
LTB300DC
LTB350DC
LTB400DC
Conduit
Size
Unit
Qty.
Std.
Pkg.
A
B
C
D
3/ 8"
25
25
15
8
5
4
2
1
1
1
1
250
250
150
80
50
40
20
10
10
6
6
1.44
1.44
1.56
2.01
2.18
2.19
2.21
2.89
2.93
3.07
3.15
.96
1.08
1.33
1.56
1.94
2.19
2.66
3.28
3.80
4.28
4.78
.62
.62
.82
1.02
1.36
1.60
2.07
2.51
3.13
3.58
4.05
.47
.47
.47
.57
.71
.71
.71
1.06
1.06
1.06
1.06
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
UL File No. E-6225
Applications:
• Lazy-Lug liquidtight conduit fittings provide an easy, versatile
method to use an external grounding conductor with liquidtight
flexible metallic conduit as permitted by the National Electrical
Code.
• This section allows an external bonding jumper to be used with a 6foot or shorter length of liquidtight conduit.
90° Angle Connectors – Non-Insulated
UL File No. E-19189
Features and Benefits:
Liquidtight
Cat. #
LT3890DC
LT5090DC
LT7590DC
LT10090DC
LT12590DC
LT15090DC
LT20090DC
LT25090DC
LT30090DC
LT35090DC
LT40090DC
Conduit
Size
Unit
Qty.
Std.
Pkg.
A
B
C
D
3/ 8"
25
25
15
8
5
4
2
1
1
1
1
250
250
150
80
50
40
20
10
10
6
6
.62
.62
.80
1.02
1.36
1.61
2.08
2.51
3.13
3.58
4.06
.81
.91
1.15
1.38
1.77
2.01
2.58
3.15
3.67
4.17
4.74
.92
1.02
1.27
1.48
1.93
2.17
2.68
3.21
3.74
4.23
4.75
1.22
1.22
1.36
1.73
2.11
2.43
2.93
3.62
4.28
4.84
5.37
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
• Open lug design allows installer to quickly lay in the grounding
conductor.
• Aluminum lug – for copper or aluminum grounding conductors.
• Copper lug – for copper grounding conductors.
Certifications and Compliances:
• UL Standard 514B – Fittings for Conduit and Outlet Boxes
• UL Standard 467 – Grounding and Bonding Equipment
Straight Connectors – Non-Insulated – Malleable
Iron – Aluminum Lug
90° Angle Connectors – Insulated
Cat. #
Cat. #
LTB3890DC
LTB5090DC
LTB7590DC
LTB10090DC
LTB12590DC
LTB15090DC
LTB20090DC
LTB25090DC
LTB30090DC
LTB35090DC
LTB40090DC
128
Conduit
Size
Unit
Qty.
Std.
Pkg.
A
B
C
D
3/ 8"
25
25
15
8
5
4
2
1
1
1
1
250
250
150
80
50
40
20
10
10
6
6
.62
.62
.80
1.02
1.36
1.61
2.08
2.51
3.13
3.58
4.06
.81
.91
1.15
1.38
1.77
2.01
2.58
3.15
3.67
4.17
4.74
.92
1.02
1.27
1.48
1.93
2.17
2.68
3.21
3.74
4.23
4.75
1.22
1.22
1.36
1.73
2.11
2.43
2.93
3.62
4.28
4.84
5.37
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
US: 1-866-764-5454
CAN: 1-800-265-0502
LT38G
LT50G
LT75G
LT100G
LT125G
LT150G
LT200G
LT250G
LT300G
LT350G
LT400G
LT500G†
LT600G†
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
250MCM – #6
250MCM – #6
25
25
25
5
5
2
1
1
1
1
1
1
1
100
100
100
50
25
20
10
5
5
5
5
1
1
18
20
26
45
69
85
120
340
430
510
600
800
1100
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
†Not UL Listed
Copyright© 2007 Cooper Crouse-Hinds
Liquidtight Conduit Fittings
• Zinc Die Cast Liquidtight Fittings
• Grounding Type Liquidtight Flexible Metallic
Conduit Fittings
Straight Connectors – Insulated – Malleable Iron –
Aluminum Lug
45° Angle Connectors – Insulated – Malleable Iron –
Aluminum Lug
Cat. #
LTB38G
LTB50G
LTB75G
LTB100G
LTB125G
LTB150G
LTB200G
LTB250G
LTB300G
LTB350G
LTB400G
LTB500G†
LTB600G†
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
250MCM – #6
250MCM – #6
25
25
25
5
5
2
1
1
1
1
1
1
1
100
100
100
50
25
20
10
5
5
5
5
1
1
18
20
26
45
69
86
120
340
430
510
600
720
750
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
†Not UL Listed
Note:
Cat. #
LTB3845G
LTB5045G
LTB7545G
LTB10045G
LTB12545G
LTB15045G
LTB20045G
LTB25045G
LTB30045G
LTB35045G
LTB40045G
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
10
10
5
2
1
1
1
1
—
100
100
50
50
25
10
5
1
1
1
1
29
41
41
70
93
137
195
600
925
1150
1450
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
90° Angle Connectors – Non-Insulated – Malleable
Iron – Aluminum Lug
For other connector and lug combinations, consult factory.
Straight Connectors – Non-Insulated – Aluminum –
Aluminum Lug
Cat. #
Cat. #
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
25
5
5
2
1
1
1
1
1
25
25
25
5
5
2
1
1
1
1
1
12
12
14
28
34
48
54
121
174
245
279
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
US: 1-866-764-5454
CAN: 1-800-265-0502
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
32
33
48
76
112
155
230
900
1383
1875
2325
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Copyright© 2007 Cooper Crouse-Hinds
Liquidtight
LT38G SA
LT50G SA
LT75G SA
LT100G SA
LT125G SA
LT150G SA
LT200G SA
LT250G SA
LT300G SA
LT350G SA
LT400G SA
Conduit
Size
LT3890G
LT5090G
LT7590G
LT10090G
LT12590G
LT15090G
LT20090G
LT25090G
LT30090G
LT35090G
LT40090G
Conduit
Size
129
• Zinc Die Cast Liquidtight Fittings
• Grounding Type Liquidtight Flexible Metallic
Liquidtight Conduit Fittings
90° Angle Connectors – Insulated – Malleable Iron –
Aluminum Lug
GROUNDING TYPE LIQUIDTIGHT
FLEXIBLE METALLIC CONDUIT FITTINGS
Straight Connectors – Insulated – Copper Lug
Cat. #
LTB3890G
LTB5090G
LTB7590G
LTB10090G
LTB12590G
LTB15090G
LTB20090G
LTB25090G
LTB30090G
LTB35090G
LTB40090G
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #83
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
—
5
1
1
1
1
30
33
48
76
112
155
230
900
1300
1800
2300
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
90° Angle Connectors – Non-Insulated – Aluminum
– Aluminum Lug
Cat. #
LTB38GC
LTB50GC
LTB75GC
LTB100GC
LTB125GC
LTB150GC
LTB200GC
LTB250GC
LTB300GC
LTB350GC
LTB400GC
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
25
5
5
2
1
1
1
1
1
100
100
100
50
25
20
10
5
5
5
5
20
22
28
47
71
88
122
351
441
532
622
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
45° Angle Connectors – Insulated – Copper Lug
Conduit
Size
Liquidtight
Cat. #
LT3890G SA
LT5090G SA
LT7590G SA
LT10090G SA
LT12590G SA
LT15090G SA
LT20090G SA
Note:
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Lug
Size
#4
#4
#4
#4
#4
#4
#4
–
–
–
–
–
–
–
#14
#14
#14
#14
#14
#14
#14
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
25
10
10
5
2
1
25
25
25
5
5
2
1
19
18
24
40
48
61
86
For other connector and lug combinations, consult factory.
Cat. #
LTB3845GC
LTB5045GC
LTB7545GC
LTB10045GC
LTB12545GC
LTB15045GC
LTB20045GC
LTB25045GC
LTB30045GC
LTB35045GC
LTB40045GC
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
31
43
43
72
95
139
197
611
936
1172
1472
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
90° Angle Connectors – Insulated – Copper Lug
Cat. #
LTB3890GC
LTB5090GC
LTB7590GC
LTB10090GC
LTB12590GC
LTB15090GC
LTB20090GC
LTB25090GC
LTB30090GC
LTB35090GC
LTB40090GC
Note:
130
US: 1-866-764-5454
CAN: 1-800-265-0502
Conduit
Size
Lug
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#4 – #14
#1/0 – #8
#1/0 – #8
#3/0 – #6
#3/0 – #6
25
25
10
10
5
2
1
1
1
1
1
100
100
50
50
25
10
5
1
1
1
1
32
35
50
78
114
157
232
911
1311
1822
2322
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
For other connector and lug combinations, consult factory.
Copyright© 2007 Cooper Crouse-Hinds
• Combination Couplings for Coupling Liquidtight
to Threaded Rigid/IMC – Grounding Type –
Aluminum Lug
• Wire Mesh Grips for Liquidtight
Metallic Conduit Fittings
Liquidtight Conduit Fittings
COMBINATION COUPLINGS FOR
COUPLING LIQUIDTIGHT TO THREADED
RIGID/IMC – GROUNDING TYPE –
ALUMINUM LUG
Conduit
Size
Cat. #
LTR38G*
LTR50G
LTR75G
LTR100G
LTR125G
LTR150G
LTR200G
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Lug
Size
#4
#4
#4
#4
#4
#4
#4
–
–
–
–
–
–
–
#14
#14
#14
#14
#14
#14
#14
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
25
25
25
5
5
2
1
100
100
100
50
25
20
10
24
30
35
59
81
107
162
*For 3/ 8" Liquidtight to 1/ 2" Rigid/IMC
Note:
For other connector and lug combinations, consult factory.
Copper lugs are available also. Consult factory for details.
REPLACEMENT LIQUIDTIGHT FERRULES
For Steel Connectors Only
Cat. #
FEA38
FEA50
FEA75
FEA100
FEA125
FEA150
FEA200
FEA250
FEA300
FEA350
FEA400
Conduit
Size
Unit
Qty.
3/ 8"
100
100
100
100
50
50
10
10
10
10
10
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
WIRE MESH GRIPS FOR LIQUIDTIGHT
METALLIC CONDUIT FITTINGS
Applications:
Liquidtight
• Wire mesh grips are used with Liquidator liquidtight conduit fittings
to prevent conduit pullout due to stress, tension, strain, vibration, or
movement.
• Typical applications include the wiring of machine tools, motors,
transformers, food processing, equipment, robotics, or any
application that requires a flexible liquidtight conduit connection.
Wire Mesh Grip – Dimensions
Dimensions
Cat. #
WMG38
WMG50
WMG75
WMG100
WMG125
WMG150
WMG200
Conduit
Size
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
A
B
Unit
Qty.
Wt. Lbs.
Per 100
67/ 16"
61/ 8"
615/ 16"
83/ 16"
103/ 4"
1113/ 16"
147/ 16"
11/ 4"
17/ 16"
15/ 8"
115/ 16"
23/ 8"
23/ 4"
35/ 16"
10
10
10
10
2
2
1
10
12
17
21
37
56
79
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
131
• LiQuik™ Liquidtight Fittings
Liquidtight Conduit Fittings
LiQuik™ LIQUIDTIGHT FITTINGS
No disassembly required! The LiQuik liquidtight fittings are quick and
easy to install in 2 steps, offering huge labor saving potential. Available
in trade sizes 3/ 8"–2" straight insulated.
Traditional Assembly Installation
1. Slide nut over conduit.
4. Slide the conduit assembly inside body.
2. Slide compression ring over conduit.
5. Slide compression nut and ring towards the connector.
3. Thread ferrule inside the conduit.
6. Tighten the nut.
Liquidtight
New LiQuik Assembly Installation
In Just 2 Steps:
1. Slide conduit inside the fully assembled connector.
2. Turn the connector assembly or the conduit until the ferrule threads
engage the spirals in the conduit. The pins in the ferrule are locked
inside the holes in the connector body, preventing the ferrule from
turning. Tighten the nut against the connector.
LiQuik™ Liquidtight Fittings – Straight,
Non-Insulated
LiQuik™ Liquidtight Fittings – Straight, Insulated
Dimensions
Dimensions
Cat. #
LTQ38
LTQ50
LTQ75
LTQ100
LTQ125
LTQ150
LTQ200
Conduit
Size
KO
Size
Unit
Qty.
Wt. Lbs.
Per 100
A
B
C
3/ 8"
1/ 2"
3/ 4"
15
18
29
40
55
71
99
11/ 8"
11/ 4"
11/ 4"
17/ 16"
11/ 2"
15/ 8"
13/ 4"
1/ 2"
3/ 4"
25
25
25
5
5
2
1
11/ 8"
11/ 4"
19/ 16"
113/ 16"
21/ 4"
27/ 16"
3"
1/ 2"
1"
11/ 4"
11/ 2"
2"
1/ 2"
1"
11/ 4"
11/ 2"
2"
1/ 2"
1/ 2"
5/ 8"
11/ 16"
3/ 4"
3/ 4"
Cat. #
LTQB38
LTQB50
LTQB75
LTQB100
LTQB125
LTQB150
LTQB200
Conduit
Size
KO
Size
3/ 8"
1/ 2"
3/ 4"
3/ 4"
1/ 2"
1"
11/ 4"
11/ 2"
2"
1/ 2"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Wt. Lbs.
Per 100
25
25
25
5
5
2
1
16
18
29
40
56
71
100
A
B
11/ 8"
9/ 16"
11/ 8"
11/ 4" 9/ 16" 11/ 4"
11/ 4" 9/ 16" 19/ 16"
17/ 16" 11/ 16" 113/ 16"
11/ 2" 3/ 4" 21/ 4"
15/ 8" 13/ 16" 27/ 16"
13/ 4" 13/ 16" 3"
Replacement LiQuik™ Ferrules
Cat. #
Conduit
Size
Wt. Lbs.
Per 100
3/ 8"
100
100
100
100
50
50
10
LTQF38
LTQF50
LTQF75
LTQF100
LTQF125
LTQF150
LTQF200
132
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
C
Liquidtight Conduit Fittings
LTK Low Profile Series
Applications:
Standard Finishes:
• Flexible metalic (liquidtight) conduit used with Cooper CrouseHinds® Liquidtight fittings is designed to protect conductors from
mechanical damage due to vibration and movement while sealing
out cutting oils, coolants, water, dust, etc.
• Typical applications include the wiring of machine tools, motors,
transformers, food processing equipment, robotics, air conditioning
units, illuminated signs, etc.
• The low profile liquidtight fittings are designed specifically for OEM
applications that require close side-by-side mounting of multiple
liquidtight fittings in tight spaces.
•
•
•
•
Certifications and Compliances:
• NEC:
Class I, Division 2 (Zone 2)
Class II, Division 1 and 2
Class III, Division 1 and 2
• UL Standards: 514B, 467
• CSA Standard: C22.2 No. 18
Standard Materials:
•
•
•
•
•
Body – steel (straight fittings), malleable iron (angle fittings)
Gland nut – steel
Ferrule – steel
Gland nut sealing ring – nylon
Sealing gasket – polypropylene
Conduit
Size
Steel – zinc electroplate
Malleable iron – zinc electroplate
Nylon – natural
Polypropylene – natural
Insulated
Cat. #
Straight Connectors
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
LTK38
LTK50
LTK75
LTK100
LTK125
LTK150
LTK200
LTBK38
LTBK50
LTBK75
LTBK100
LTBK125
LTBK150
LTBK200
45° Connectors
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
LTK3845
LTK5045
LTK7545
LTK10045
LTK12545
LTK15045
LTK20045
LTBK3845
LTBK5045
LTBK7545
LTBK10045
LTBK12545
LTBK15045
LTBK20045
90° Connectors
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
LTK3890
LTK5090
LTK7590
LTK10090
LTK12590
LTK15090
LTK20090
LTBK3890
LTBK5090
LTBK7590
LTBK10090
LTBK12590
LTBK15090
LTBK20090
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Liquidtight
Non-insulated
Cat. #
133
Liquidtight Conduit Fittings
LTK Low Profile Series
Replacement Ferrules
Conduit
Size
Cat. #
3/ 8"
LTKF38
LTKF50
LTKF75
LTKF100
LTKF125
LTKF150
LTKF200
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Dimensions In Inches:
Straight Connectors
Conduit
Size
Over Round
Corner
A1 (in.)
Over Hex
A2 (in.)
B (in.)
13/ 32
13/ 16
17/ 16
13/ 4
25/ 32
23/ 8
27/ 8
11/ 32
11/ 8
13/ 8
111/ 16
21/ 16
29/ 32
225/ 32
13/ 16
111/ 32
17/ 16
15/ 8
127/ 32
2
21/ 8
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
N.P.T.
Thread Length
C (in.)
19/ 32
19/ 32
19/ 32
21/ 32
43/ 64
23/ 32
23/ 32
45°Connectors
Conduit
Size
Over Round
Corner
A1 (in.)
Over Hex
A2 (in.)
B (in.)
C (in.)
13/ 32
11/ 32
17/ 32
15/ 16
13/ 8
121/ 32
123/ 32
2
29/ 32
11/ 32
11/ 32
11/ 8
11/ 4
111/ 32
115/ 32
15/ 8
19/ 32
113/ 32
21/ 32
11/ 16
23/ 32
23/ 32
N.P.T.
Thread Length
D (in.)
3/ 8"
1/ 2"
13/ 16
17/ 16
13/ 4
25/ 32
23/ 8
27/ 8
11/ 32
13/ 8
111/ 16
21/ 16
29/ 32
225/ 32
Over Round
Corner
A1 (in.)
Over Hex
A2 (in.)
B (in.)
Over
C (in.)
13/ 32
13/ 16
17/ 16
13/ 4
25/ 32
23/ 8
27/ 8
11/ 32
11/ 8
13/ 8
111/ 16
21/ 16
29/ 32
225/ 32
119/ 32
121/ 32
125/ 32
23/ 16
33/ 8
25/ 8
31/ 16
11/ 4
11/ 4
117/ 32
127/ 32
115/ 16
23/ 32
213/ 32
Liquidtight
3/ 4"
1"
11/ 4"
11/ 2"
2"
N.P.T.
Thread Length
D (in.)
19/ 32
90° Connectors
Conduit
Size
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
134
US: 1-866-764-5454
CAN: 1-800-265-0502
19/ 32
19/ 32
113/ 32
21/ 32
11/ 16
23/ 32
23/ 32
Copyright© 2007 Cooper Crouse-Hinds
Nonmetallic Liquidtight
Conduit Fittings
Applications:
• For use with nonmetallic Type B liquidtight conduit to terminate and
seal conduit to liquidtight, oiltight, or raintight box or enclosure.
• Typical applications include wiring motors, transformers, processing
equipment, pumps, etc.
Features:
•
•
•
•
•
•
Liquidtight, Raintight Oiltight
Furnished with locknut and sealing ring
Corrosion resistant
Suitable for wet locations
No-Spin ferrule
90° has smooth interior to prevent abrasion of conductors
Standard Materials:
• Body – Nylon
• Locknut – Zinc Die Cast
Straight Connectors
Dimensions
Cat. #
LT50NM
LT75NM
LT100NM
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
A
1/ 2"
25
10
5
250
150
80
6
8
10
.55
.72
.94
Conduit
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
A
1/ 2"
25
10
5
150
100
50
7
9
13
.55
.72
.94
3/ 4"
1"
B
C
.85 .56
1.08 .72
1.30 .94
Liquidtight
Conduit
Size
90° Connectors
Dimensions
Cat. #
LT5090NM
LT7590NM
LT10090NM
3/ 4"
1"
US: 1-866-764-5454
B
C
.85 .56
1.08 .72
1.30 .94
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
135
Cord And Cable Connectors
CG Series Color-Coded Cord Grips
Applications:
Features:
CG Series color-coded grips with neoprene bushings are for use with
portable cords, including S, SO, STO, ST, SJ, SJT, SJTO, and SVO.
CG cord grips are installed to:
• Provide a means for passing a cord into an enclosure
• Form a watertight seal for cord
• Provide pullout protection for cord, ensuring a secure connection
• Neoprene bushings are color coded by cable diameter for quick and
easy identification of proper cord grip.
• Rugged construction protects cord from damage.
• Compact design permits close spacing of fittings on panel
applications.
• Tightening one nut creates watertight seal.
• Male tapered thread NPT.
• Available in straight, 45° and 90° entrance configurations.
Standard Materials and Finishes:
•
•
•
•
Straight Body – electrogalvanized steel
Angled Body – electrogalvanized malleable iron
Nut – electrogalvanized steel
Bushing – neoprene/natural
Certifications and Compliances:
•
•
•
•
UL Standard: 514B
CSA Standard: C22.2 No. 18
Suitable for NEMA 4 enclosures and other wet locations
Suitable for use in hazardous locations when installed in
accordance with NEC 501.4(B), 502.4(A) and 503.3(A).
• For Class I, Div.2, Class II, Div. 1 and 2 and Class III, Div. 1 and 2.
STRAIGHT BODY
Cord & Cable
Cat. #
Trade
Size
Color
Size
Cable
Range Min.
Cable
Range Max.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Red
White
Blue
Green
0.15
0.25
0.35
0.45
0.25
0.35
0.45
0.56
25
25
25
25
100
100
100
100
10
10
10
10
Brown
Red
White
Blue
0.55
0.15
0.25
0.35
0.65
0.25
0.35
0.45
25
10
10
10
100
50
50
50
10
14
14
14
3/ 4"
Green
Brown
Yellow
Purple
0.45
0.55
0.65
0.75
0.56
0.65
0.75
0.85
10
10
10
10
50
50
50
50
14
14
14
14
CG50
CG50
CG50
CG50
250
350
450
560
1/ 2"
CG50
CG75
CG75
CG75
650
250
350
450
1/ 2"
CG75
CG75
CG75
CG75
560
650
750
850
3/ 4"
1/ 2"
1/ 2"
1/ 2"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
CG100
CG100
CG100
CG100
560
650
750
850
1"
1"
1"
1"
Green
Brown
Yellow
Purple
0.45
0.55
0.65
0.75
0.56
0.65
0.75
0.85
5
5
5
5
25
25
25
25
20
20
20
20
CG100
CG100
CG125
CG125
950
1050
850
950
1"
1"
11/ 4"
11/ 4"
Gray
Black
Purple
Gray
0.85
0.95
0.75
0.85
0.95
1.05
0.85
0.95
5
5
5
5
25
25
25
25
20
20
40
40
CG125
CG125
CG125
CG125
1050
1150
1250
1375
11/ 4"
11/ 4"
11/ 4"
11/ 4"
Black
Orange
Red
White
0.95
1.05
1.15
1.25
1.05
1.15
1.25
1.375
5
5
5
5
25
25
25
25
40
40
40
40
CG150
CG150
CG150
CG150
1050
1150
1250
1375
11/ 2"
11/ 2"
11/ 2"
11/ 2"
Black
Orange
Red
White
0.95
1.05
1.15
1.25
1.05
1.15
1.25
1.375
2
2
2
2
10
10
10
10
70
70
70
70
136
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Cord And Cable Connectors
CG Series Color-Coded Cord Grips
45° BODY
Cat. #
Trade
Size
Color
Size
Cable
Range Min.
Cable
Range Max.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Red
White
Blue
Green
0.15
0.25
0.35
0.45
0.25
0.35
0.45
0.56
10
10
10
10
50
50
50
50
24
24
24
24
Brown
Red
White
Blue
0.55
0.15
0.25
0.35
0.65
0.25
0.35
0.45
10
10
10
10
50
50
50
50
24
36
36
36
3/ 4"
Green
Brown
Yellow
Purple
0.45
0.55
0.65
0.75
0.56
0.65
0.75
0.85
10
10
10
10
50
50
50
50
36
36
36
36
1"
1"
1"
1"
Green
Brown
Yellow
Purple
0.45
0.55
0.65
0.75
0.56
0.65
0.75
0.85
5
5
5
5
25
25
25
25
68
68
68
68
1"
1"
Gray
Black
0.85
0.95
0.95
1.05
5
5
25
25
68
68
CG5045
CG5045
CG5045
CG5045
250
350
450
560
1/ 2"
CG5045
CG7545
CG7545
CG7545
650
250
350
450
1/ 2"
CG7545
CG7545
CG7545
CG7545
560
650
750
850
3/ 4"
CG10045
CG10045
CG10045
CG10045
560
650
750
850
CG10045 950
CG10045 1050
1/ 2"
1/ 2"
1/ 2"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
90° BODY
Cat. #
Color
Size
Cable
Range Min.
Cable
Range Max.
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
Red
White
Blue
Green
0.15
0.25
0.35
0.45
0.25
0.35
0.45
0.56
10
10
10
10
50
50
50
50
26
26
26
26
Brown
Red
White
Blue
0.55
0.15
0.25
0.35
0.65
0.25
0.35
0.45
10
10
10
10
50
50
50
50
26
48
48
48
3/ 4"
Green
Brown
Yellow
Purple
0.45
0.55
0.65
0.75
0.56
0.65
0.75
0.85
10
10
10
10
50
50
50
50
48
48
48
48
1"
1"
1"
1"
Green
Brown
Yellow
Purple
0.45
0.55
0.65
0.75
0.56
0.65
0.75
0.85
5
5
5
5
25
25
25
25
68
68
68
68
1"
1"
Gray
Black
0.85
0.95
0.95
1.05
5
5
25
25
68
68
CG5090
CG5090
CG5090
CG5090
250
350
450
560
1/ 2"
CG5090
CG7590
CG7590
CG7590
650
250
350
450
1/ 2"
CG7590
CG7590
CG7590
CG7590
560
650
750
850
3/ 4"
CG10090
CG10090
CG10090
CG10090
560
650
750
850
CG10090 950
CG10090 1050
1/ 2"
1/ 2"
1/ 2"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
3/ 4"
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Cord & Cable
Trade
Size
137
Cord And Cable Connectors
NCG Series Nonmetallic Cord Grips
Applications:
Features:
For use with portable cord, NCG Series watertight cord grips
terminate and protect conductors from mechanical damage due to
vibration and movement. A neoprene bushing seals out oils, coolants,
water, dust and other abusive agents. NCG cord grips may be used
with types S, SO, STO, SJ, SJT, SJTO and SVO portable cords.
Typical applications include the termination of wiring for:
• Machine tools
• Motors
• Transformers
• Food processing equipment
• Robotics
• Air conditioning units
• Illuminated signs
• Terminal boxes
• Control cabinets
• Available in 3/ 8" to 1" trade sizes.
• Neoprene bushings cover a large cable range, reducing the number
of different fittings required.
• Polyamide nonmetallic construction stands up to most corrosive
environments.
• Polyamide locknut available, order separately.
• UL listed and cUL third party certified.
• Rain-tight and watertight construction for outdoor use.
• Tightening one nut creates watertight seal.
Certifications and Compliances:
•
•
•
•
•
Standard Materials:
UL Standard 514B
cUL to CSA Standard C22.2 No.18
IP 68
NEMA 4X Watertight
Zone 2, Division 2 use per Code
• Cable gland body and nut – polyamide 6
• Bushing – neoprene
• Locknut – polyamide 6
Cat. #
NCG38 35
NCG50 50
NCG75 75
NCG100 100
Trade Size
Cable Range Inches (MM)
Std. Pkg.
3/ 8"
0.1–0.35 (2.5–8)
0.20–0.50 (5–12)
0.35–0.75 (9–18)
0.55–1.00 (14–25)
25
25
25
20
1/ 2"
3/ 4"
1"
Locknuts – must be ordered separately
Cat. #
Trade Size
Std. Pkg.
3/ 8"
25
25
25
20
1/ 2"
3/ 4"
1"
Cord & Cable
10N
11N
12N
13N
138
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
• Set Screw Type Connectors
• Straight, 45°, and 90°
Armored and Metal
Clad Cable Fittings
ACB Series Connectors
ARMORED AND METAL CLAD
CABLE CONNECTORS – STEEL
ACB SERIES
Applications:
• ACB Series Connectors are used to connect armored cable, metal
clad cable or flexible metallic conduit to a box or enclosure.
Features and Benefits:
• Dual gripping saddle design on the connector safely secures cable
or conduit in place and prevents loosening from vibration.
• Insulated throat provides a smooth pulling surface that won't strip
cable.
• Angled teeth on locknut bite into enclosure, preventing loosening
from vibration.
• Tri-head set screw may be installed using a slotted, Phillips or
Robertson head Screwdriver.
• Steel connector is zinc electroplated for corrosion resistance.
45° Connectors*
Certifications and Compliances:
Cable
Opening
• UL Listed
• cUL Listed
Cat. #
Materials and Finishes:
•
•
•
•
ACB3845
ACB5045
ACB7545
Body: Steel – Zinc electroplated
Saddle: Steel – Zinc electroplated
Screw: Steel – Zinc electroplated
Insulated throat: Thermoplastic – Natural
Trade
Size
3/ 8"
1/ 2"
3/ 4"
Max.
Min.
0.656 0.437
0.937 0.750
1.125 0.906
Dimensions
Unit
Qty.
Std.
Pkg.
50
25
10
200
100
50
Unit
Qty.
Std.
Pkg.
A
50
25
10
5
200
100
50
25
13/ 4"
21/ 8"
21/ 2"
213/ 16"
A
B
C
113/ 16" 113/ 16" 15/ 16"
21/ 8" 21/ 8" 11/ 4"
23/ 8" 23/ 8" 17/ 16"
*45° not available in 1" size
90° Connectors
Straight Connectors
Cable
Opening
Cable
Opening
Cat. #
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Max.
Min.
Unit
Qty.
Std.
Pkg.
A
0.656
0.937
1.125
1.468
1.500
1.750
2.031
3.062
3.562
4.060
4.560
0.437
0.750
0.906
1.250
1.312
1.562
1.812
2.812
3.312
3.620
4.120
50
25
10
5
5
5
1
1
1
1
1
200
100
50
25
10
10
5
5
5
1
1
13/ 16"
13/ 8"
13/ 8"
19/ 16"
23/ 16"
27/ 16"
29/ 16"
211/ 16"
213/ 16"
215/ 16"
3"
US: 1-866-764-5454
B
C
11/ 4" 1/ 2"
11/ 4" 7/ 16"
17/ 16" 7/ 16"
113/ 16" 1/ 2"
21/ 8" 5/ 8"
21/ 2" 5/ 8"
5/ 8"
3"
35/ 8" 13/ 16"
41/ 4" 15/ 16"
1"
33/ 4"
53/ 16" 11/ 16"
CAN: 1-800-265-0502
Cat. #
ACB3890
ACB5090
ACB7590
ACB10090
Trade
Size
3/ 8"
1/ 2"
3/ 4"
1"
Max. Min.
0.656
0.937
1.125
1.468
0.437
0.750
0.906
1.250
Copyright© 2007 Cooper Crouse-Hinds
Dimensions
B
C
21/ 16" 1"
21/ 4" 11/ 4"
21/ 2" 13/ 8"
27/ 8" 111/ 16"
139
Cable Fittings
ACB38
ACB50
ACB75
ACB100
ACB125
ACB150
ACB200
ACB250
ACB300
ACB350
ACB400
Trade
Size
Dimensions
• Compression Type Couplings
• Set Screw Type Couplings
• Space Saver ACB
Armored and Metal
Clad Cable Fittings
ARMORED AND METAL CLAD
COUPLINGS – STEEL
ACC SERIES
Applications:
ARMORED AND METAL CLAD
CONNECTORS – STEEL
SPACE SAVER ACB SERIES
Features:
• ACC combination couplings are used to join EMT conduit to
armored cable, metal clad cable or flexible metallic conduit.
• Male threads on locknut allow for more
room inside the box
• Smooth pulling surface eliminates the
need for insulated throat fittings and/or
conduit bushings
• Angled teeth on locknut bite into
enclosure, preventing loosening from
vibration
• Dual gripping saddle design on the fitting
safely secures cable or conduit in place
and prevents loosening from vibration
• Tri-head set screw may be installed using
a slotted, Philips, or Robertson head
screwdriver
• Steel fitting is zinc electroplated for
corrosion resistance
• Suitable for use with steel or aluminum
cables
Features and Benefits:
• Dual gripping saddle design on the coupling safely secures cable or
conduit in place and prevents loosening from vibration
• Steel compression ring & nut provide a strong, secure termination
point for EMT conduit.
• Tri-head set screw may be installed using a slotted, Phillips or
Robertson head screwdriver.
• Steel combination coupling is zinc electroplated for corrosion
resistance.
Materials and Finishes:
• Body: Steel – Zinc electroplated
• Saddle: Steel – Zinc electroplated
• Screw: Steel – Zinc electroplated
Certifications and Compliances:
Certifications and Compliances:
• UL Listed
• cUL Listed
• UL Listed
• cUL Listed
Compression Coupling:
UL File No. E-22132
Cable Opening
Cat. #
ACC38
ACC50
ACC75
Trade
Size
3/ 8"
1/ 2"
3/ 4"
Max.
Min.
Unit
Qty.
0.656
0.937
1.125
0.437
0.750
0.906
25
10
10
Cable Fittings
Set-Screw Coupling:
Cat. #
ACCSS38*
ACCSS50
ACCSS75
Cable
Opening
Cat. #
Trade
Size
Unit
Qty.
Wt. Lbs.
Per 100
3/ 8"
25
10
10
9
12
14
1/ 2"
3/ 4"
SSACB38
SSACB50
SSACB75
SSACB100
Trade
Size
KO
Size Max. Min.
3/ 8"
1/ 2"
3/ 4"
3/ 4"
1/ 2"
1"
1/ 2"
1"
0.640
0.930
1.125
1.405
*not UL Listed
140
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
0.280
0.635
0.810
0.775
Dimensions
Unit
Qty.
Wt. Lbs.
Per 100
50
25
20
5
9
12
14
30
A
B
13/ 8" 3/ 4"
13/ 8" 11/ 16"
11/ 2" 11/ 4"
2" 19/ 16"
• Set Screw
• Quik-Lok
• Duplex
Armored and Metal
Clad Cable Fittings
ARMORED CABLE CONNECTORS –
MALLEABLE IRON
ARMORED CABLE CONNECTORS –
MALLEABLE IRON
Set Screw Type
Duplex Type
UL File No. E-19188
UL File No. E-19188
Cat. #
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
702V
3/ 8"
5/ 8"
7/ 16"
Unit
Qty.
Wt. Lbs.
Per 100
100
For 2 conductor No.'s 14, 12
3 conductor No.'s 14, 12
4 conductor No. 14, 5/ 16" flex
7
QUICK-LOK® CONNECTORS FOR
ARMORED AND METAL CLAD CABLE –
STEEL
Features:
• No Locknut required
• Single-unit or duplex construction with
captive clamp
• Connects 50 MC, AC, and Flex RW cable
sizes with just three fittings
• Easy to install: tilt, insert and snap down
• Single unit construction eliminates loose
component parts, integral green plastic
insulated throat bushing provides maximum
protection for wire installation
• Concrete tight when taped
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
5/ 8"
9/ 16"
25
100
20
90 Degree
3/ 8"
700*
5/ 8"
9/ 16"
25
100
14
Cat. #
Straight
699*
*UL Listed as grounding means.
ARMORED & METAL CLAD – ZINC DIE
CAST
Duplex Type
UL File No. E-19188
Cat. #
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
2699*
3/ 8"
5/ 8"
9/ 16"
25
250
13
*UL Listed as grounding means.
Standard Materials:
• Tubular Steel
Standard Finishes:
• Zinc plated
UL File No. E-19188
QLK50S
Trade
Size
1/ 2"
QLK75
QLK50D
1/ 2"
Unit
Qty.
single
50
3/ 4"
25
duplex
25
Cable Fittings
Cat. #
Wt. Lbs.
Per 100
9
For 14 / 4 to 1 0/ 3
For 3/ 8" FMC
11.5
For 10 / 3 to 6 / 3
For 3/ 8" and 1/ 2" FMC
11
For 14 / 4 to 10 / 3
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
141
• Clamp Type
• Clamps
• Anti-Short Bushings
Armored and Metal
Clad Cable Fittings
ARMORED CABLE CONNECTORS –
MALLEABLE IRON
Features:
CLAMPS – STEEL
Light Gauge
• Male hub treads – NPSM
Standard Materials:
• Mallable Iron
• Steel locknut
• Stamped steel covers
Cat. #
Conduit
Sizes
Rigid
Size of
Strap
Inside
Unit
Qty.
Wt. Lbs.
Per 100
1/ 4"
.540
.675
500
200
2
2
566
567
Standard Finishes:
• Zinc Plated
3/ 8"
ANTI-SHORT BUSHINGS
Clamp Type 45° Angle – Non-Insulated
UL File No. E-19188 or E-19189
Cat. #
Cat. #
723
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
3/ 8"
21/ 32"
17/ 32"
Unit
Qty.
Wt. Lbs.
Per 100
50
14
For 2 conductor No.'s 14, 12, 10
3 conductor No.'s 14, 12, 10
4 conductor No.'s 14, 12
Flexible metallic conduit 5/ 16" and 3/ 8"
735
1/ 2"
15/ 16"
737
3/ 4"
11/ 8"
9/ 16"
25
For 2 conductor No. 8
Flexible metallic conduit 1/ 2"
25/ 32"
25
For 2 conductor No.'s 6, 4
3 conductor No.'s 6, 4
Flexible metallic conduit 3/ 4"
18
24
Clamp Type 45° Angle – Insulated
Cable Fittings
UL File No. E-19188 or E-19189
Cat. #
1723
1735
1737
142
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
3/ 8"
21/ 32"
17/ 32"
3/ 4"
11/ 8"
25/ 32"
1/ 2"
15/ 16"
9/ 16"
Unit
Qty.
Wt. Lbs.
Per 100
50
25
25
14
17
24
US: 1-866-764-5454
CAN: 1-800-265-0502
Unit
Qty.
Std.
Pkg.
ASB 0
5/ 16"
14 – 2, 14 – 3, 12 – 2
100 22,500
ASB 1
3/ 8"
14 – 4, 12 – 3, 6 – 1, 4 – 1
100 18,000
ASB 2
7/ 16"
12 – 4, 10 – 2, 10 – 3, 2 – 1
50
ASB 3
1/ 2"
10 – 4, 8 – 2, 8 – 3, 1 – 1
50
5,250
ASB 4
3/ 4"
8 – 4, 6 – 4, 6 – 3, 6 – 2, 4 – 3, 4 – 2
50
3,000
ASB 5
1"
3 – 1, 2 – 1, 2 – 1 / 0, 1 – 300 MCM
1 – 350 MCM, 1 – 400 MCM,
1 – 450 MCM, 1 – 500 MCM
25
3,125
ASB 6
11/ 4"
4 – 1, 4 – 1 / 0, 4 – 2 / 0, 3 – 1 / 0,
3 – 2 / 0, 3 – 3 / 0, 2 – 2 / 0, 2 – 3 / 0
2 – 4 / 0, 1 – 600 MCM, 1 – 650
MCM, 1 – 700 MCM, 1 – 750
MCM, 1 – 800 MCM, 1 – 900
MCM
10
1,500
ASB 7
11/ 2"
4 – 3 / 0, 4 – 4 / 0, 3 – 4 / 0, 3 – 250
MCM, 3 – 300 MCM, 2 – 250
MCM, 2 – 300 MCM, 2 – 350
MCM, 1 – 1000 MCM
10
1,000
2" to
21/ 2"
4
4
4
3
3
2
2
10
1,000
ASB 8
Trade
Size
FMC
Trade
Size Armoured Cable Size
–
–
–
–
–
–
–
250
350
450
350
450
400
500
MCM,
MCM,
MCM,
MCM,
MCM,
MCM,
MCM
4
4
4
3
3
2
–
–
–
–
–
–
300
400
500
400
500
450
Bushings are packed in clear poly bags.
Anti-short bushings have a temperature rating of 90°C
Copyright© 2007 Cooper Crouse-Hinds
MCM,
MCM,
MCM,
MCM,
MCM,
MCM,
10,000
• Set Screw Type Connectors
• Straight, 45° and 90°
Flexible Metallic
Conduit Fittings
ACB Series Connectors
FLEXIBLE METALLIC CONDUIT
CONNECTORS – STEEL
ACB SERIES
Applications:
• ACB Series Connectors are used to connect armored cable, metal
clad cable or flexible metallic conduit to a box or enclosure.
Features:
• Dual gripping saddle design on the connector safely secures cable
or conduit in place and prevents loosening from vibration.
• Insulated throat provides a smooth pulling surface that won't strip
cable.
• Angled teeth on locknut bite into enclosure, preventing loosening
from vibration.
• Tri-head set screw may be installed using a slotted, Phillips or
Robertson head Screwdriver.
• Steel connector is zinc electroplated for corrosion resistance.
45° Connectors*
Cable
Opening
Certifications and Compliances:
• UL Listed
• cUL Listed
Cat. #
ACB3845
ACB5045
ACB7545
Materials and Finishes:
•
•
•
•
Body: Steel – Zinc electroplated
Saddle: Steel – Zinc electroplated
Screw: Steel – Zinc electroplated
Insulated throat: Thermoplastic – Natural
Trade
Size
3/ 8"
1/ 2"
3/ 4"
Max.
Min.
0.656 0.437
0.937 0.750
1.125 0.906
Dimensions
Unit
Qty.
Std.
Pkg.
50
25
10
200
100
50
Unit
Qty.
Std.
Pkg.
A
50
25
10
5
200
100
50
25
13/ 4"
21/ 8"
21/ 2"
213/ 16"
A
B
C
113/ 16" 113/ 16" 15/ 16"
21/ 8" 21/ 8" 11/ 4"
23/ 8" 23/ 8" 17/ 16"
*45° not available in 1" size
90° Connectors
Straight Connectors
Cable
Opening
Cat. #
Cable
Opening
Cat. #
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Dimensions
Max.
Min.
Unit
Qty.
0.656
0.937
1.125
1.468
1.500
1.750
2.031
3.062
3.562
4.060
4.560
0.437
0.750
0.906
1.250
1.312
1.562
1.812
2.812
3.312
3.620
4.120
50
25
10
5
5
5
1
1
1
1
1
Std.
Pkg.
A
200
100
50
25
10
10
5
5
5
1
1
13/ 16"
13/ 8"
13/ 8"
19/ 16"
23/ 16"
27/ 16"
29/ 16"
211/ 16"
213/ 16"
215/ 16"
3"
US: 1-866-764-5454
B
C
11/ 4" 1/ 2"
11/ 4" 7/ 16"
17/ 16" 7/ 16"
113/ 16" 1/ 2"
21/ 8" 5/ 8"
21/ 2" 5/ 8"
5/ 8"
3"
35/ 8" 13/ 16"
41/ 4" 15/ 16"
1"
33/ 4"
53/ 16" 11/ 16"
CAN: 1-800-265-0502
3/ 8"
1/ 2"
3/ 4"
1"
Max. Min.
0.656
0.937
1.125
1.468
Copyright© 2007 Cooper Crouse-Hinds
0.437
0.750
0.906
1.250
Dimensions
B
C
21/ 16" 1"
21/ 4" 11/ 4"
21/ 2" 13/ 8"
27/ 8" 111/ 16"
143
Cable Fittings
ACB38
ACB50
ACB75
ACB100
ACB125
ACB150
ACB200
ACB250
ACB300
ACB350
ACB400
Trade
Size
ACB3890
ACB5090
ACB7590
ACB10090
Trade
Size
• Compression Type Couplings
• Set Screw Type Couplings
• Spacesaver ACB
Flexible Metallic
Conduit Fittings
FLEXIBLE METALLIC CONDUIT
COUPLINGS – STEEL
ACC SERIES
Applications:
FLEXIBLE METALLIC CONDUIT,
CONNECTORS – STEEL
SPACE SAVER ACB SERIES
Features:
• ACC combination couplings are used to join EMT conduit to
armored cable, metal clad cable or flexible metallic conduit.
• Male threads on locknut allow for more
room inside the box
• Smooth pulling surface eliminates the
need for insulated throat fittings and/or
conduit bushings
• Angled teeth on locknut bite into
enclosure, preventing loosening from
vibration
• Dual gripping saddle design on the fitting
safely secures cable or conduit in place
and prevents loosening from vibration
• Tri-head set screw may be installed using
a slotted, Philips, or Robertson head
screwdriver
• Steel fitting is zinc electroplated for
corrosion resistance
• Suitable for use with steel or aluminum
cables
Features:
• Dual gripping saddle design on the coupling safely secures cable or
conduit in place and prevents loosening from vibration
• Steel compression ring & nut provide a strong, secure termination
point for EMT conduit.
• Tri-head set screw may be installed using a slotted, Phillips or
Robertson head screwdriver.
• Steel combination coupling is zinc electroplated for corrosion
resistance.
Materials and Finishes:
• Body: Steel – Zinc electroplated
• Saddle: Steel – Zinc electroplated
• Screw: Steel – Zinc electroplated
Certifications and Compliances:
Certifications and Compliances:
• UL Listed
• cUL Listed
• UL Listed
• cUL Listed
Compression Coupling:
UL File No. E-22132
Cable Opening
Cat. #
ACC38
ACC50
ACC75
Trade
Size
3/ 8"
1/ 2"
3/ 4"
Max.
Min.
Unit
Qty.
0.656
0.937
1.125
0.437
0.750
0.906
25
10
10
Cable Fittings
Set-Screw Coupling:
Cat. #
ACCSS38*
ACCSS50
ACCSS75
Cable
Opening
Cat. #
Trade
Size
Unit
Qty.
Wt. Lbs.
Per 100
3/ 8"
25
10
10
9
12
14
1/ 2"
3/ 4"
SSACB38
SSACB50
SSACB75
SSACB100
Trade
Size
KO
Size Max. Min.
3/ 8"
1/ 2"
3/ 4"
3/ 4"
1/ 2"
1"
1/ 2"
1"
0.640
0.930
1.125
1.405
*not UL Listed
144
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
0.280
0.635
0.810
0.775
Dimensions
Unit
Qty.
Wt. Lbs.
Per 100
50
25
10
5
9
12
14
30
A
B
13/ 8" 3/ 4"
13/ 8" 11/ 16"
11/ 2" 11/ 4"
2" 19/ 16"
• Set Screw
• Quik-Lok
• Duplex
Flexible Metallic
Conduit Fittings
FLEXIBLE METALLIC CONDUIT
CONNECTORS – MALLEABLE IRON
FLEXIBLE METALLIC CONDUIT
CONNECTORS – MALLEABLE IRON
Set Screw Type
Duplex Type
UL File No. E-19188
UL File No. E-19188
Trade
Size
Cat. #
702V
Diam. of
Opening
for Cable
3/ 8"
5/ 8"
Diam. of
Bushed
Hole
Unit
Qty.
Wt. Lbs.
Per 100
7/ 16"
100
For 2 conductor No.'s 14, 12
3 conductor No.'s 14, 12
4 conductor No. 14, 5/ 16" flex
7
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
5/ 8"
9/ 16"
25
100
20
90 Degree
3/ 8"
700*
5/ 8"
9/ 16"
25
100
14
Cat. #
Straight
699*
*UL Listed as grounding means.
QUICK-LOK® CONNECTORS FOR FMC –
STEEL
Features:
• No Locknut required
• Single-unit or duplex construction with captive
clamp
• Connects 50 MC, AC, and Flex RW cable
sizes with just three fittings
• Easy to install: tilt, insert and snap down
• Single unit construction eliminates loose
component parts, integral green plastic
insulated throat bushing provides maximum
protection for wire installation
• Concrete tight when taped
FLEXIBLE METALLIC CONDUIT
CONNECTORS – ZINC DIE CAST
Duplex Type
UL File No. E-19188
Cat. #
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
2699*
3/ 8"
5/ 8"
9/ 16"
25
250
13
*UL Listed as grounding means.
Standard Materials:
• Tubular Steel
Standard Finishes:
• Zinc plated
UL File No. E-19188
QLK50S
Trade
Size
1/ 2"
QLK75
QLK50D
1/ 2"
Unit
Qty.
single
50
3/ 4"
25
duplex
25
Cable Fittings
Cat. #
Wt. Lbs.
Per 100
9
For 14 / 4 to 10 / 3
For 3/ 8" FMC
11.5
For 10 / 3 to 6 / 3
For 3/ 8" and 1/ 2" FMC
11
For 14 / 4 to 10 / 3
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
145
• Squeeze Type Connectors
Flexible Metallic
Conduit Fittings
FLEXIBLE METALLIC CONDUIT
CONNECTORS – MALLEABLE IRON
Standard Materials:
FLEXIBLE METALLIC CONDUIT
CONNECTORS – ZINC DIE CAST
• Malleable Iron
• Steel Locknut
UL File No. E-19188
Squeeze Type* – Straight – Insulated
Standard Finishes:
• Zinc plated
Squeeze Type*
Cat. #
UL File No. E-19189
Cat. #
707†
708‡
709
710
711
712
713
714
715
721
722
Trade
Size
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Diam. of
Opening.
for Cable
Diam. of
Bushed
Hole
5/ 8"
15/ 16"
3/ 8"
11/ 8"
13/ 8"
121/ 32"
17/ 8"
21/ 2"
27/ 8"
39/ 16"
4"
419/ 32"
5/ 8"
3/ 4"
1"
15/ 16"
11/ 2"
2"
23/ 8"
3"
213/ 32"
331/ 32"
Unit
Qty.
Wt. Lbs.
Per 100
100
50
20
20
10
5
2
2
1
1
1
7
14
22
31
46
79
101
161
220
470
610
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
†Suitable for use with armored cable.
‡Suitable for use with metal clad cable.
Straight – Insulated*
Cable Fittings
UL File No. E-19189
Cat. #
1707†
1708‡
1709
1710
1711
1712
1713
1714
1715
1721
1722
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
3/ 8"
5/ 8"
3/ 8"
11/ 8"
13/ 8"
121/ 32"
17/ 8"
21/ 2"
27/ 8"
39/ 16"
4"
419/ 32"
3/ 4"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
15/ 16"
5/ 8"
1"
15/ 16"
11/ 2"
2"
23/ 8"
3"
313/ 32"
331/ 32"
Unit
Qty.
Wt. Lbs.
Per 100
100
50
20
20
10
5
2
2
1
1
1
8
14
17
26
42
77
100
160
221
470
610
1707DC
1708DC
1709DC
1710DC
1711DC
1712DC
1713DC
1714DC
1715DC
1721DC
1722DC
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
50
25
25
10
10
5
4
2
1
1
1
500
250
250
100
100
50
40
10
5
1
1
6
8
11
16
21
28
36
85
109
144
183
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
Squeeze Type* – Straight – Non-Insulated
Cat. #
707DC
708DC
709DC
710DC
711DC
712DC
713DC
714DC
715DC
721DC
722DC
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
50
25
25
10
10
5
4
2
1
1
1
500
250
250
100
100
50
40
10
5
1
1
6
8
11
16
21
28
36
85
109
144
183
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
†Suitable for use with armored cable.
‡Suitable for use with metal clad cable.
146
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
• Clamp Type 45° and 90° Connectors
Flexible Metallic
Conduit Fittings
FLEXIBLE METALLIC CONDUIT
CONNECTORS – MALLEABLE IRON
Features:
FLEXIBLE METALLIC CONDUIT
CONNECTORS – MALLEABLE IRON
Clamp Type* 90° Angle – Non-Insulated
UL File No. E-19188 or E-19189
• Male hub treads – NPSM
Standard Materials:
• Mallable Iron
• Steel locknut
• Stamped steel covers
Standard Finishes:
Trade
Size
Diam. of
Opening
for Cable
724†
3/ 8"
21/ 32"
736†
738†
739
740
741
742
744
745
746
747
1/ 2"
Cat. #
• Zinc Plated
Clamp Type 45° Angle – Non-Insulated
UL File No. E-19188 or E-19189
Cat. #
723
Trade
Size
Diam. of
Opening
for Cable
3/ 8"
21/ 32"
Diam. of
Bushed
Hole
Unit
Qty.
Wt. Lbs.
Per 100
17/ 32"
50
14
For 2 conductor No.'s 14, 12, 10
3 conductor No.'s 14, 12, 10
4 conductor No.'s 14, 12
Flexible metallic conduit 5/ 16" and 3/ 8"
735
1/ 2"
15/ 16"
737
3/ 4"
11/ 8"
9/ 16"
25
For 2 conductor No. 8
Flexible metallic conduit 1/ 2"
25/ 32"
25
For 2 conductor No.'s 6, 4
3 conductor No.'s 6, 4
Flexible metallic conduit 3/ 4"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
24
UL File No. E-19188 or E-19189
1723
1735
1737
3/ 8"
21/ 32"
17/ 32"
3/ 4"
11/ 8"
25/ 32"
1/ 2"
15/ 16"
9/ 16"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
25
200
100
100
14
17
24
1736†
1738†
1739
1740
1741
1742
1744
1745
1746
1747
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
1/ 2"
15/ 16"
9/ 16"
13/ 16"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
11/ 8"
113/ 32"
121/ 32"
17/ 8"
21/ 2"
3"
31/ 2"
4"
419/ 32"
1"
11/ 4"
11/ 2"
115/ 16"
21/ 2"
3"
313/ 32"
331/ 32"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
/100
25
20
5
2
1
1
1
1
1
1
100
100
25
10
10
5
1
1
1
1
19
31
50
113
188
236
400
600
1150
1460
Cable Fittings
Cat. #
17/ 32"
50
15
For 2 conductor No.'s 14, 12, 10
3 conductor No.'s 14, 12, 10
4 conductor No.'s 14, 12
Flexible metallic conduit 5/ 16" and 3/ 8"
15/ 16"
9/ 16"
25
19
13/ 16"
20
31
11/ 8"
1"
5
50
113/ 32"
2
113
121/ 32"
11/ 4"
1
188
17/ 8"
11/ 2"
1
236
115/ 16"
21/ 2"
3"
1
400
21/ 2"
3"
1
600
31/ 2"
4"
1
1150
313/ 32"
1
1460
419/ 32"
331/ 32"
Clamp Type 90° Angle – Insulated
Cat. #
Diam. of
Bushed
Hole
Wt. Lbs.
/100
18
UL File No. E-19188 or E-19189
Diam. of
Opening
for Cable
Unit
Qty.
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
†Suitable for use with armored cable.
Clamp Type 45° Angle – Insulated
Trade
Size
Diam. of
Bushed
Hole
†Suitable for use with armored cable.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
147
• Squeeze Type 90°
• Screw-In Type Connectors
• Screw-In Type Couplings
Flexible Metallic
Conduit Fittings
FLEXIBLE METALLIC CONDUIT
CONNECTORS – ZINC DIE CAST
FLEXIBLE METALLIC CONDUIT
FITTINGS – ZINC DIE CAST
Squeeze Type* 90° Angle – Non-Insulated
Straight Connectors – Non-Insulated
Screw-in Type
UL File No. 19189
UL File No. E-19189
Cat. #
Trade
Size
724DC
736DC
738DC
739DC
740DC
741DC
742DC
744DC
745DC
746DC
747DC
3/ 8"
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Unit
Qty.
50
25
10
5
10
1
1
1
1
1
1
Std.
Pkg.
500
250
100
50
40
5
5
1
1
1
1
Wt. Lbs.
Per 100
8
11
15
25
41
117
119
286
405
560
642
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
Cat. #
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
80
60
35
15
10
6
3
800
600
350
150
100
60
30
5
5
9
13
24
35
52
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
1/ 2"
40
25
15
10
6
3
400
250
150
100
60
30
4
8
12
21
31
44
770DC
771DC
772DC
773DC
774DC
775DC
776DC
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Couplings
Screw-in Type
UL File No. 19189
Squeeze Type* 90° Angle – Insulated
UL File No. 19189
Cat. #
Cable Fittings
Cat. #
1724DC
1736DC
1738DC
1739DC
1740DC
1741DC
1742DC
1744DC
1745DC
1746DC
1747DC
Trade
Size
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
3/ 8"
50
25
10
5
10
1
1
1
1
1
1
500
250
100
50
40
5
5
1
1
1
1
8
11
15
25
41
117
119
286
405
560
642
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
791DC
792DC
793DC
794DC
795DC
796DC
3/ 4"
1"
11/ 4"
11/ 2"
2"
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
148
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
• Combination Couplings
• Back to Back
• Anti-Short
Flexible Metallic
Conduit Fittings
ANTI-SHORT BUSHINGS
COMBINATION COUPLINGS –
ZINC DIE CAST
EMT (Set Screw) to Flexible Steel (Clamp)*
UL File No. E-19189
FMC
Trade
Size
Cat. #
Cat. #
780DC
Trade
Size
1/ 2"
to 3/ 8"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
500
8
*UL Listed flexible metallic conduit fittings are suitable as grounding means under NEC 3505 and suitable for hazardous location use per Class I, Division 2, NEC 501-4(b).
"BACK TO BACK" BOX CONNECTOR –
ZINC DIE CAST
Cat. #
5050
Size
Unit
Qty.
Wt. Lbs.
Per 100
1/ 2"
25
8
Armoured
Cable
Size
Unit
Qty.
Std.
Pkg.
ASB 0
5/ 16"
14 – 2, 14 – 3, 12 – 2
100 22,500
ASB 1
3/ 8"
14 – 4, 12 – 3, 6 – 1, 4 – 1
100 18,000
ASB 2
7/ 16"
12 – 4, 10 – 2, 10 – 3, 2 – 1
50
10,000
ASB 3
1/ 2"
10 – 4, 8 – 2, 8 – 3, 1 – 1
50
5,250
ASB 4
3/ 4"
8 – 4, 6 – 4, 6 – 3, 6 – 2, 4 – 3,
4–2
50
3,000
ASB 5
1"
3 – 1, 2 – 1, 2 – 1 / 0, 1 – 300 MCM
1 – 350 MCM, 1 – 400 MCM,
1 – 450 MCM, 1 – 500 MCM
25
3,125
10
1,500
10
1,000
10
1,000
ASB 6
11/ 4"
4 – 1, 4 – 1 / 0, 4 – 2 / 0, 3 – 1 / 0,
3 – 2 / 0, 3 – 3 / 0, 2 – 2 / 0,
2–3/0
2 – 4 / 0, 1 – 600 MCM, 1 – 650
MCM, 1 – 700 MCM, 1 – 750
MCM, 1 – 800 MCM, 1 – 900
MCM
ASB 7
11/ 2"
4 – 3 / 0, 4 – 4 / 0, 3 – 4 / 0, 3 – 250
MCM, 3 – 300 MCM, 2 – 250
MCM, 2 – 300 MCM, 2 – 350
MCM, 1 – 1000 MCM
4
4
4
ASB 8 2" to 21/ 2" 3
3
2
2
Note:
–
–
–
–
–
–
–
250
350
450
350
450
400
500
MCM,
MCM,
MCM,
MCM,
MCM,
MCM,
MCM
4
4
4
3
3
2
–
–
–
–
–
–
300
400
500
400
500
450
MCM,
MCM,
MCM,
MCM,
MCM,
MCM,
Bushings are packed in clear poly bags.
Anti-short bushings have a temperature rating of 90°C
Cable Fittings
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
149
• Clamp Type
• Duplex Type
Nonmetallic Cable
Connectors
NONMETALLIC SHEATHED CABLE AND
PORTABLE CORD CONNECTORS – STEEL
NONMETALLIC CABLE – ZINC DIE CAST
Duplex Type
UL File No. E-19188
Clamp Type
UL File No. E-22132
Clamp Opening
K.O.
Size
Min.
Max.
631
3/ 4"
33/ 64"
13/ 16"
13/ 16"
20
14
For 2 conductor No.'s 8, 6
3 conductor No.'s 8, 6
632
1"
3/ 8"
11/ 64"
10
21
11/ 64"
For 2 conductor No.'s 8, 6
3 conductor No.'s 8, 6
Cat. #
Width
Unit
Qty.
Wt. Lbs.
Per 100
Cat. #
Trade
Size
Diam. of
Opening
for Cable
Diam. of
Bushed
Hole
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
2699*
3/ 8"
5/ 8"
9/ 16"
25
250
13
*UL Listed as grounding means.
NONMETALLIC SHEATHED CABLE
CONNECTORS – ZINC DIE CAST
Cable Fittings
UL File No. E-10438
Cat. #
Trade
Size
K.O.
Size
759DC
3/ 8"
1/ 2"
100
1000
4
For 2 conductor No.'s 14, 12, 10
3 conductor No.'s 14, 12
2631
3/ 4"
3/ 4"
50
500
9
For 3 conductor No.'s 8, 6
2632
1"
1"
25
250
12
For 3 conductor No.'s 6, 4
2633
11/ 4"
11/ 4"
10
100
22
For 3 conductor No.'s 3, 2
2670
11/ 2"
11/ 2"
5
50
25
For 3 conductor No. 2 / 0
2671
2"
2"
10
40
40
For 3 conductor No. 4 / 0
150
Unit
Qty.
Std.
Pkg.
US: 1-866-764-5454
Wt. Lbs.
Per 100
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
• Service Entrance Elbows – Aluminum
• Entrance Caps
Service Entrance and
Grounding Fittings
SERVICE ENTRANCE FITTINGS
SERVICE ENTRANCE FITTINGS
Applications:
Service Entrance Elbows – Aluminum
Gasketed
• Use in overhead service entrance
• Mounts on top of EMT, Rigid or IMC conduit
• Serves as a connecting point for service
entrance wires
• Available in Clamp Type, Set-Screw, Threaded
and Mast Type styles
UL File No. E-19189
Cat. #
Size
SLB1
SLB2
SLB3
SLB4
SLB5
SLB6
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
10
10
5
2
1
1
50
50
25
10
5
5
25
30
51
83
117
192
UL File No. E-153721
Std.
Pkg.
Wt. Lbs.
Per 100
15
10
7
5
3
8
3
3
2
2
90
60
42
30
18
8
3
2
2
2
11
21
27
32
53
89
300
322
513
519
15
10
7
5
3
8
3
3
2
2
90
60
42
30
18
8
3
2
2
2
19
24
24
28
51
81
272
298
538
541
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
15
10
7
5
3
8
3
3
2
2
90
60
42
30
18
8
3
2
2
2
15
18
24
28
58
86
308
308
517
517
11/ 4" – 2"
11/ 4" – 2"
11/ 2" – 21/ 2"
2" – 21/ 2"
2
1
2
1
12
10
12
6
45
75
73
75
Size
Clamp Type
EHC1
EHC2
EHC3
EHC4
EHC5
EHC6
EHC7
EHC8
EHC9
EHC10
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Threaded Type
EHT1
EHT2
EHT3
EHT4
EHT5
EHT6
EHT7
EHT8
EHT9
EHT10
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Set Screw Type
EHSS1
EHSS2
EHSS3
EHSS4
EHSS5
EHSS6
EHSS7
EHSS8
EHSS9
EHSS10
Mast Type
EHMT1
EHMT2
EHMT3
EHMT4
US: 1-866-764-5454
CAN: 1-800-265-0502
1/ 2"
3/ 4"
Copyright© 2007 Cooper Crouse-Hinds
Service Entrance/Grounding
Unit
Qty.
Cat. #
151
•
•
•
•
Service Entrance and
Grounding Fittings
Service Entrance Cable Connectors
Perforated Strap
Ground Straps
Ground Clamp
Service Entrance Cable Connectors – Malleable Iron
Non-watertight for Oval Cable
PERFORATED STRAP – STEEL
10 Foot Coils
UL File No. E-22134
Cat. # Description
Clamp
Opening Width
Cat. #
K.O. Size
Min.
Max.
3/ 4"
33/ 64"
13/ 16"
1"
3/ 8"
631
632
3000
Std.
Pkg.
Wt. Lbs.
Per 100
200
14
For 2 conductor No.'s 8, 6
3 conductor No.'s 8, 6
3/ 4
× .035 Galvanized
holes – 1/ 2" to 1" Centers
1/ 4"
Cat. #
141DC
Grounding
Conductor
Electrode
Clamping
Range
1/ 2", 3/ 4",
1"
Lug
Conductor
Range
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
#8 – #2
25
300
16
Clamp Opening
Cat. # K.O. Size Min. Max. Width
.075"
.920"
.960"
1.00"
1.30"
.075"
.920"
.960"
1.00"
1.30"
Unit
Qty.
Std.
Pkg.
Wt. Lbs.
Per 100
50
25
10
5
10
500
250
100
50
40
9
12
22
25
40
Service Entrance/Grounding
.300"
.350"
.335"
.350"
.700"
152
10
100
21
11/ 64"
For 2 conductor No.'s 8, 6
3 conductor No.'s 8, 6
UL File No. E-10438
1"
11/ 4"
11/ 2"
2"
10
For Bare or Insulated Wire or Armored Grounding
Cable
Non-watertight for Oval Cable
3/ 4"
Wt. Lbs.
Per 100
GROUND CLAMP – ZINC DIE CAST
Service Entrance Cable Connectors – Zinc Die Cast
2631
2632
2633
2670
2671
Unit
Qty.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Cable Fittings
Reference Chart
Cat. #
AC
MC
FMC
FLEX
to
EMT
AC/
FLEX
to
EMT
Armored
Cables
Steel &
Aluminum
Metal Clad
Cables
Steel &
Aluminum
AC 0.470min / 12/4max FE & AL
MCI 0.470min / 0.500max FE
14/2, 14/3,
14/4, 12/2,
12/3,12/4
.470/.560
ST: 14/2, 14/3,
14/4, 12/2,
.470/.500
FE RWFMC
12/4
AL: 14/4
ST: 12/3
FE RWFMC
Cable Ranges
NM
SE
631
•
•
For 2 conductor No.'s 8, 6
3 conductor No.'s 8, 6
632
•
•
For 2 conductor No.'s 8, 6
3 conductor No.'s 8, 6
699
•
•
•
700
•
•
•
707
•
•
•
AC 0.560, MCI 0.500 FE & AL
•
MCI 0.870 AL
708
•
AL: 6/3
Conduit
Cable Type
FE RWFMC
709
•
FE RWFMC
710
•
FE RWFMC
711
•
FE RWFMC
712
•
FE RWFMC
713
•
FE RWFMC
714
•
FE RWFMC
715
•
FE RWFMC
721
•
FE RWFMC
722
•
723
724
•
•
•
•
FE RWFMC
AC 0.470min / 12/4max FE & AL
MCI 0.470min / 0.640max FE
MCI 0.500min / 0.630max AL
•
AC 0.460min / 12/4max FE & AL
MCI 0.500min / 0.630max FE
MCI 0.500min / 0.640max AL
•
•
736
•
FE RWFMC
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
.460/.550
AL: 14/4, 12/2,
12/3, 12/4,
10/2, 10/3,
10/4, 8/2,
.500/.630
ST: 12/3, 12/4,
10/2, 10/3,
10/4, 8/2,
.500/.630
FE RWFMC
FE RWFMC
Cable Fittings
735
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
.470/.550
AL: 14/4, 12/2,
12/3, 12/4,
10/2, 10/3,
10/4, 8/2,
.500/.630
ST: 14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
10/2, 10/3,
10/4, 8/2,
.470/.630
FE RWFMC
737
•
•
•
AC 0.990 FE & AL
MCI 0.950min /1.020max FE & AL
738
•
•
•
AC 0.920min / 4/3max FE & AL
MCI 0.840 FE
MCI 0.880min / 1.030max AL
4/3
6/4, 4/3
.950/1.020
FE RWFMC
6/4, 4/3,
.920/1.100
AL: 6/3, 6/4,
4/3,
.880/1.030
ST: 6/3
FE RWFMC
739
•
FE RWFMC
740
•
FE RWFMC
741
•
FE RWFMC
742
•
FE RWFMC
744
•
FE RWFMC
745
•
FE RWFMC
746
•
FE RWFMC
747
•
FE RWFMC
AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit
FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
153
Cable Fittings
Reference Chart
Armored
Cables
Steel &
Aluminum
Cable Ranges
AC
MC
FMC
1707
•
•
•
AC 0.560, MCI 0.500 FE & AL
•
•
MCI 0.870 AL
Metal Clad
Cables
Steel &
Aluminum
Conduit
Cable Type
AL: 6/3
FE RWFMC
FE RWFMC
1709
•
FE RWFMC
1710
•
FE RWFMC
1711
•
FE RWFMC
1712
•
FE RWFMC
1713
•
FE RWFMC
1714
•
FE RWFMC
1715
•
FE RWFMC
1721
•
FE RWFMC
1722
•
1723
•
1735
•
1736
•
1737
1738
Cable Fittings
SE
AC/
FLEX
to
EMT
Cat. #
1708
NM
FLEX
to
EMT
•
•
•
•
FE RWFMC
AC 0.470min / 12/4max FE & AL
MCI 0.470mon / 0.640max FE
MCI 0.500min / 0.630max AL
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
.470/.550
AL: 14/4, 12/2, 12/3, 12/4,
10/2, 10/3, 10/4, 8/2, .500/.630
ST: 14/2, 14/3, 14/4, 12/2,
12/3, 12/4, 10/2, 10/3,
10/4, 8/2, .470/.630
FE RWFMC
FE RWFMC
FE RWFMC
•
AC 0.990 FE & AL
MCI 0.950min /1.020max FE & AL
•
AC 0.920min / 4/3max FE & AL
MCI 0.840 FE
MCI 0.880min / 1.030max AL
4/3
6/4, 4/3,
.950/1.020
FE RWFMC
6/4, 4/3,
.920/1.100
AL: 6/3, 6/4, 4/3,
.880/1.030
ST: 6/3
FE RWFMC
1739
•
FE RWFMC
1740
•
FE RWFMC
1741
•
FE RWFMC
1742
•
FE RWFMC
1744
•
FE RWFMC
1745
•
FE RWFMC
1746
•
FE RWFMC
1747
•
FE RWFMC
2631
•
•
For 3 conductor No.'s 8, 6
2632
•
•
For 3 conductor No.'s 6, 4
2633
•
•
For 3 conductor No.'s 3, 2
2670
•
•
For 3 conductor No. 2/0
2671
•
•
For 3 conductor No. 4/0
2699
•
•
•
1707DC
•
1708DC
•
1709DC
•
1710DC
•
1711DC
•
1712DC
•
1713DC
•
1714DC
•
1715DC
•
1721DC
•
1722DC
•
1724DC
•
1736DC
•
1738DC
•
AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit
FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit
154
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Cable Fittings
Reference Chart
Cat. #
AC
MC
FMC
1739DC
•
1740DC
•
1741DC
•
1742DC
•
1744DC
•
1745DC
•
1746DC
•
1747DC
702V
SE
AC/
FLEX
to
EMT
Cable Ranges
Armored
Cables
Steel &
Aluminum
Metal Clad
Cables
Steel &
Aluminum
Conduit
Cable Type
•
•
•
•
707DC
•
708DC
•
709DC
•
710DC
•
711DC
•
712DC
•
713DC
•
714DC
•
715DC
•
721DC
•
722DC
•
724DC
•
736DC
•
738DC
•
739DC
•
740DC
•
741DC
•
742DC
•
744DC
•
745DC
•
746DC
•
747DC
•
759DC
For 2 conductor No.s 14, 12, 10
3 conductor No.'s 14, 12
•
•
771DC
•
772DC
•
773DC
•
774DC
•
775DC
•
776DC
•
780DC
Cable Fittings
770DC
791DC
NM
FLEX
to
EMT
•
•
792DC
•
793DC
•
794DC
•
795DC
•
796DC
•
AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit
FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
155
Cable Fittings
Reference Chart
Cat. #
MC
FMC
NM
SE
AC/
FLEX
to
EMT
Cable Ranges
AC 0.930min / 1/4max FE & AL
MCI 0.960min / 1.468max FE & AL
Armored
Cables
Steel &
Aluminum
Metal Clad
Cables
Steel &
Aluminum
6/4, 4/3,
4/4, 3/2,
3/3, 2/3,
2/4, 1/3,
1/4,
.930/1.468
6/4, 4/3,
4/4, 3/3,
3/4,
.960/1.468
Conduit
Cable Type
FEFMC
ACB100
•
•
•
ACB125
•
•
•
FEFMC
ACB150
•
•
•
FEFMC
ACB200
•
•
•
FEFMC
ACB250
•
•
•
FEFMC
ACB300
•
•
•
FEFMC
ACB350
•
•
•
AC 0.450min / 10/2max FE & AL
MCI 0.450min / 0.660max FE & AL
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
10/2,
.450/.660
FEFMC
•
AC 0.550min / 6/3max FE & AL
MCI 0.640min / 0.920max FE & AL
12/4, 10/2,
10/3, 10/4,
8/2, 8/3,
8/4, 6/2,
6/3,
.550/.920
10/2, 10/3,
10/4, 8/2,
8/3,
.640/.920
FEFMC
•
AC 0.930min / 4/3max FE
AC 0.680min / 4/3max AL
MCI 0.730min / 1.075max FE
MCI 0.930min / 1.075max AL
AL: 8/3, 8/4,
6/2, 6/3,
6/4, 4/2, 4/3,
.680/1.075
ST: 6/4, 4/2,
4/3,
.930/1.075
AL: 6/4, 4/3,
3/3,
.930/1.075
ST: 8/3, 8/4,
6/2, 6/3,
6/4, 4/3,
3/3,
.730/1.075
FEFMC
•
•
•
ACB400
•
•
•
ACB75
•
•
•
•
FEFMC
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
10/2,
.450/.660
ACB38
ACB50
Cable Fittings
AC
FLEX
to
EMT
ACC38
•
•
ACC50
•
•
ACC75
•
•
ACCSS38
•
•
ACCSS50
•
•
ACCSS75
•
•
ASB 0
•
•
ASB 1
•
•
14/2, 14/3, 12/2
14/4, 12/3, 6/1, 4/1
ASB 2
•
•
12/2, 10/2, 10/3, 2/1
ASB 3
•
•
10/4, 8/2, 8/3, 1/1
ASB 4
•
•
8/4, 6/4, 6/3, 6/2, 4/3, 4/2
ASB 5
•
•
3/1, 2/1, 2-1/0, 1-300 MCM,
1-350 MCM, 1-400 MCM,
1-450 MCM, 1-500 MCM
ASB 6
•
•
4/1, 4-1/0, 4-2/0, 3-1/0,
3-2/0, 3-3/0, 2-2/0, 2-3/0,
2-4/0, 1-600 MCM, 1-650 MCM,
1-700 MCM, 1-750 MCM,
1-800 MCM, 1-900 MCM,
ASB 7
•
•
4-3/0, 4-4/0, 3-4/0,
3-250 MCM, 3-300 MCM,
2-250MCM, 2-300 MCM,
2-350 MCM, 1-1000 MCM
ASB 8
•
•
4-250
4-400
3-350
3-500
2-500
MCM,
MCM,
MCM,
MCM,
MCM
4-300
4-450
3-400
2-400
MCM,
MCM,
MCM,
MCM,
4-350
4-500
3-450
2-450
MCM,
MCM,
MCM,
MCM,
AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit
FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit
156
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Cable Fittings
Reference Chart
NM
SE
FLEX
to
EMT
AC/
FLEX
to
EMT
Cable Ranges
Armored
Cables
Steel &
Aluminum
Metal Clad
Cables
Steel &
Aluminum
Conduit
Cable Type
Cat. #
AC
MC
FMC
QLK50D
•
•
•
14/2, 14/3,
14/4, 12/2,
12/3, 12/4
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
10/2
QLK50S
•
•
•
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
10/2, 10/3
14/2, 14/3,
14/4, 12/2,
12/3, 12/4,
10/2
QLK75
•
•
•
10/4, 10/5,
8/3, 8/4, 6/3
10/3, 10/4,
8/2, 8/3, 6/2,
SSACB38
•
•
•
AC 0.450min / 10/2max FE & AL
MCI 0.450min / 0.660max FE & AL
14/2, 14/3, 14/4, 12/2,
12/3, 12/4, 10/2,
.450/.660
.450/.660
FEFMC
SSACB50
•
•
•
AC 0.550min / 6/3max FE & AL
MCI 0.640min / 0920max FE & AL
12/4, 10/2, 10/3,
10/4, 8/2, 8/3,
8/4, 6/2, 6/3,
.550/.920
.640/3920
FEFMC
SSACB75
•
•
•
AC 0.930min / 4/3max FE
AC 0.680min / 4/3max AL
MCI 0.730min / 1.075max FE
MCI 0.930min / 1.075max AL
8/3, 8/4, 6/2,
6/3, 6/4, 4/2, 4/3,
.930/1.075
AL: .930/1.075
ST: .730/1.075
FEFMC
SSACB100
•
•
•
AC 0.930min / 1/4max FE & AL
MCI 0.960min / 1.468max FE & AL
6/4, 4/3, 4/4,
3/3, 3/4, 2/3,
2/4, 1/3, 1/4,
.930/1.468
.960/1.468
FEFMC
ACB3845
•
•
•
AC 0.450min / 10/2max FE & AL
MCI 0.450min / 0.660max FE & AL
14/2, 14/3, 14/4,
12/2, 12/3, 12/4, 10/2,
.450/.660
14/2, 14/3, 14/4,
12/2, 12/3,
12/4, 10/2,
.450/.660
FEFMC
ACB5045
•
•
•
AC 0.550min / 6/3max FE & AL
MCI 0.640min / 0.920max FE & AL
12/4, 10/2, 10/3,
10/4, 8/2, 8/3, 8/4,
6/2, 6/3,
.550/.920
10/2, 10/3, 10/4,
8/2, 8/3,
.640/.920
FEFMC
AL: 8/3, 8/4, 6/2,
6/3, 6/4, 4/2, 4/3,
.680/1.075
ST: 6/4, 4/2, 4/3,
.930/1.075
AL: 6/4, 4/3, 3/3,
.930/1.075
ST: 8/3, 8/4, 6/2,
6/3, 6/4, 4/3, 3/3,
.730/1.075
FEFMC
•
•
•
ACB3890
•
•
•
AC 0.450min / 10/2max FE & AL
MCI 0.450min / 0.660max FE & AL
14/2, 14/3, 14/4,
12/2, 12/3, 12/4, 10/2,
.450/.660
14/2, 14/3, 14/4,
12/2, 12/3,
12/4, 10/2,
.450/.660
FEFMC
ACB5090
•
•
•
AC 0.550min / 6/3max FE & AL
MCI 0.640min / 0.920max FE & AL
12/4, 10/2, 10/3,
10/4, 8/2, 8/3,
8/4, 6/2, 6/3,
.550/.920
10/2, 10/3,
10/4, 8/2, 8/3,
.640/.920
FEFMC
AL: 8/3, 8/4, 6/2,
6/3, 6/4, 4/2, 4/3,
.680/1.075
ST: 6/4, 4/2, 4/3,
.930/1.075
AL: 6/4, 4/3, 3/3,
.930/1.075
ST: 8/3, 8/4, 6/2,
6/3, 6/4, 4/3, 3/3,
.730/1.075
FEFMC
6/4, 4/3, 4/4,
3/2, 3/3, 2/3,
2/4, 1/3, 1/4,
.930/1.468
6/4, 4/3, 4/4,
3/3, 3/4,
.960/1.468
FEFMC
ACB7590
•
•
•
AC 0.930min / 4/3max FE
AC 0.680min / 4/3max AL
MCI 0.730min / 1.075max FE
MCI 0.930min / 1.075max AL
ACB10090
•
•
•
AC 0.930min / 1/4max FE & AL
MCI 0.960min / 1.468max FE & AL
Cable Fittings
ACB7545
AC 0.930min / 4/3max FE
AC 0.680min / 4/3max AL
MCI 0.730min / 1.075max FE
MCI 0.930min / 1.075max AL
AC = Armored Cable MCI = Metal/Clad Interlocked FE RWFMC = Steel Reduced/Wall Flexible Metallic Conduit
FE = Steel AL = Aluminum FEFMC = Steel Flexible Metallic Conduit
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
157
Junction Boxes
Application and Selection
Applications:
Junction boxes, designed for hazardous
and non-hazardous locations, are used in a
variety of industries to perform the following
functions:
• As a pull box
• To provide enclosures for splices and
taps
• As a mounting box for multi-device
control stations
• For housing apparatus, instruments, and
other devices
Considerations for
Selection:
• Number and size of conductors –
combined with the function to be
performed (i.e., splicing, pull box),
determines the amount of space needed,
and therefore, the required physical
dimensions of the box.
• Conduit layout – determines the number,
size, and location of the conduit openings
in the box. It will also determine the type
of mounting required (i.e., flush or surface
positioning of the box).
• Flexibility required – if changes in the
electrical system are anticipated, the box
chosen should be easily adaptable, either
by construction (i.e., detachable hub
plates) or size to the future system.
• Environmental location – the physical
location of the junction box will call for
proper construction of the box to meet
National Electrical Code requirements
and will affect the material and finish
needed to meet weather and corrosive
conditions, if present.
Options and Accessories:
A wide variety of options and accessories
for special application are available for the
various junction box families. These can be
selected once the type of junction box has
been determined. These options are shown
on the individual pages. Some of the
options available include:
• Special covers
• Hinged covers
• Materials and finishes
• Equipment mounting plates
• Openings for control station and other
device mounting
• Corro-free™ epoxy powder coat –
information available on request
Quick Selector Chart
Max.
Conduit
Opening
Size
Mtg.
4 × 4 × 2 to
24 × 24 × 8
5
Surface
Raintight/Type 3,
Watertight/Type 4,
Dust-tight/Type 12
4 × 4 × 2 to
24 × 24 × 8
5
WJB
Raintight/Type 3,
Watertight/Type 4
4 × 4 × 3 to
36 × 24 × 24
WJBF
Raintight/Type 3,
Watertight/Type 4
WEB
Raintight/Type 3
Environmental
Capability/Type
Designation
Size Range†
L, W, D Inside
WAB
Raintight/Type 3,
Dust-tight/Type 12
WCB
Junction
Boxes
Type of
Conduit
Opening
Cover
Type
Page
No.
Drilled and tapped,
slip holes
Unflanged
[1497]
Surface
Drilled and tapped,
slip holes
Overlapping
[1746]
6
Surface
Drilled and tapped,
slip holes
Flanged
[1747]
4 × 4 × 4 to
36 × 24 × 24
6
Flush
Drilled and tapped,
slip holes
External flanged
recessed sidewalk
[1748]
4 × 4 × 3 to
36 × 36 × 12
6
Flush
Drilled and tapped,
slip holes
Internal Flanged
[1749]
Junction Boxes
†Length and width are inside dimensions. Depth is inside dimension without cover.
Lightning Service™ Delivery Identification – Looking for junction boxes to meet tight
deadlines? Then specify Lightning Service. All products available with Lightning Service
delivery will be marked with a checkmark. Look for pages with the Lightning Service Logo
located at the top of the page.
Lightning Service is available for over 90 of the most popular size boxes in five different
styles.
Shipped within 24 hours: All enclosures marked with a check mark are available in 24 hours
without drilled and tapped openings or a mounting plate.
Shipped within 72 hours: All enclosures marked with a check mark are available in 72 hours
with standard drilled and tapped openings and/or a mounting plate.
In Canada: Enclosures without openings or mountings plate shipped within 1 week.
Enclosures with standard openings or mounting plate shipped within 2 weeks
158
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
WAB Junction Boxes
Heavy Duty
Unflanged for Surface Mounting
Dust-proof
Weatherproof
Applications:
Where a heavy duty dustproof or
weatherproof enclosure is desired, WAB
boxes are installed in conduit system to:
• Act as pull box for conductors
• Provide openings and space for making
splices and taps in conductors
• Provide for branch conduit runs
• Provide access to conductors for
maintenance and future system changes
• Enclose and protect electrical devices
Features:
• Flat neoprene gasket cemented to the
cover.
• Wide range of drilled and tapped and slip
hole conduit entrance sizes and locations
permits extreme flexibility of use in
conduit system.
• Internal equipment mounting pads
available blind tapped for 1/ 4" – 20
mounting screws.
• Blind tapped into internal mounting pads.
• Mounting straps are standard on all
boxes.
Standard Materials:
•
•
•
•
•
Feraloy iron alloy body
Heavy-gauge steel cover
Neoprene gaskets
Stainless steel cover screws
Steel mounting straps
®
Standard Finishes:
• Feraloy iron alloy and heavy gauge steel
– hot dip galvanized
Options:
Description
Factory installed mounting plate
Suffix
-MP
Size Ranges:
• 4" × 4" × 2" to 24" × 24"× 8"
Wall
Thickness (in.)
Length
(in.)
Width
(in.)
Depth
(in.)
5/ 32
4
4
4
5
5
6
6
6
6
6
8
8
8
8
8
8
9
10
10
10
10
12
12
12
12
12
12
12
16
16
18
18
18
18
18
24
24
4
4
4
5
5
4
4
6
6
6
4
6
6
8
8
8
6
6
8
8
10
6
6
8
8
12
12
12
6
12
12
12
12
18
18
12
24
2
3
4
3
4
3
4
3
4
6
3
4
6
4
6
8
4
4
4
6
6
4
6
6
8
4
6
8
6
8
6
8
10
6
12
12
8
WAB040402✓
WAB040403✓
WAB040404✓
WAB050503✓
WAB050504✓
WAB060403✓
WAB060404✓
WAB060603✓
WAB060604✓
WAB060606✓
WAB080403
WAB080604✓
WAB080606✓
WAB080804✓
WAB080806✓
WAB080808✓
WAB090604
WAB100604
WAB100804✓
WAB100806✓
WAB101006✓
WAB120604✓
WAB120606✓
WAB120806✓
WAB120808
WAB121204✓
WAB121206✓
WAB121208✓
WAB160606
WAB161208✓
WAB181206✓
WAB181208
WAB181210
WAB181806✓
WAB181812✓
WAB241212
WAB242408
3/ 16
1/ 4
1/ 4
1/ 4
1/ 4
7/ 32
1/ 4
3/ 16
9/ 32
5/ 16
7/ 32
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
1/ 4
1/ 4
9/ 32
1/ 4
9/ 32
9/ 32
9/ 32
3/ 8
9/ 32
9/ 32
9/ 32
1/ 4
5/ 16
5/ 16
5/ 16
3/ 8
3/ 8
7/ 16
7/ 16
11/ 32
Junction Boxes
See Ordering Information, beginning
pg. 164, for:
Drilled and tapped conduit holes
Slip holes
Cat. #
✓ – available with Lightning Service™
Certifications and
Compliances:
•
•
•
•
UL Standard: 50
Dust-proof
Weatherproof
H20 Vehicle Load Rating*
*Self certify to H20 vehicle load rating equivalent to
16,000 lbs. on cover center.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
159
Dust-tight
Weatherproof
Watertight
Raintight
WCB Junction Boxes
Heavy Duty
Overlapping Cover for
Surface Mounting
Applications:
Where a heavy duty dust-tight,
weatherproof, raintight, or watertight
enclosure is desired, WCB boxes are
installed in conduit systems to:
• Act as pull box for conductors
• Provide openings and space for making
splices and taps in conductors
• Provide for branch conduit runs
• Provide access to conductors for
maintenance and future system changes
• Enclose and protect electrical devices
Features:
• Flat neoprene gasket cemented to cover.
• Overlapping cover sheds environment.
• Wide range of drilled and tapped and slip
hole conduit entrance sizes and locations
permits maximum flexibility of use in
conduit system.
• Internal equipment mounting pads
available blind tapped for 1/ 4" – 20
mounting screws.
• Blind tapped into internal mounting pads.
• Mounting straps are standard on all
boxes.
Standard Materials:
•
•
•
•
Feraloy iron alloy cover and body
Neoprene gaskets
Stainless steel cover screws
Steel mounting straps
®
Standard Finishes:
• Feraloy iron alloy – hot dip galvanized
Options:
Description
Factory installed mounting plate
Junction Boxes
See Ordering Information, beginning
pg. 164, for:
Drilled and tapped conduit holes
Slip holes
Size Ranges:
• 4" × 4" × 2" to 24" × 24" × 8"
Certifications and
Compliances:
•
•
•
•
•
Suffix
-MP
Cat. #
Wall
Thickness (in.)
Length
(in.)
Width
(in.)
Depth
(in.)
5/ 32
4
4
4
5
5
6
6
6
6
6
8
8
8
8
8
8
9
10
10
10
10
12
12
12
12
12
12
12
16
16
18
18
18
18
18
24
24
4
4
4
5
5
4
4
6
6
6
4
6
6
8
8
8
6
6
8
8
10
6
6
8
8
12
12
12
6
12
12
12
12
18
18
12
24
2
3
4
3
4
3
4
3
4
6
3
4
6
4
6
8
4
4
4
6
6
4
6
6
8
4
6
8
6
8
6
8
10
6
12
12
8
WCB040402
WCB040403✓
WCB040404✓
WCB050503✓
WCB050504✓
WCB060403✓
WCB060404✓
WCB060603✓
WCB060604✓
WCB060606✓
WCB080403
WCB080604✓
WCB080606✓
WCB080804✓
WCB080806✓
WCB080808✓
WCB090604✓
WCB100604
WCB100804✓
WCB100806✓
WCB101006✓
WCB120604✓
WCB120606✓
WCB120806✓
WCB120808
WCB121204✓
WCB121206✓
WCB121208✓
WCB160606
WCB161208✓
WCB181206✓
WCB181208
WCB181210
WCB181806✓
WCB181812✓
WCB241212
WCB242408✓
3/ 16
1/ 4
1/ 4
1/ 4
1/ 4
7/ 32
1/ 4
3/ 16
9/ 32
5/ 16
7/ 32
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
1/ 4
1/ 4
9/ 32
1/ 4
9/ 32
9/ 32
9/ 32
3/ 8
9/ 32
9/ 32
9/ 32
1/ 4
5/ 16
5/ 16
5/ 16
3/ 8
3/ 8
7/ 16
7/ 16
11/ 32
✓ – available with Lightning Service™
UL Standard: 50
Dust-tight
Weatherproof
Raintight
Watertight
160
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
WJB Junction Boxes
Heavy Duty
Flanged for Surface Mounting
Weatherproof
Watertight
Raintight
Applications:
WJB boxes are standard with mounting
straps and are primarily designed for
surface mounting. WJB heavy duty junction
boxes are installed in conduit systems to:
• Act as pull box for conductors
• Provide openings and space for making
splices and taps in conductors
• Provide for branch conduit runs
• Provide access to conductors for
maintenance and future system changes
• Enclose and protect electrical equipment
Features:
• Neoprene gasket cemented to cover.
• Wide range of drilled and tapped conduit
entrance sizes and locations permits
extreme flexibility of use in conduit
system.
• Internal equipment mounting pads may
be drilled and tapped for 1/ 4" – 20
mounting screws.
• Blind tapped into internal mounting pads.
Standard Materials:
• Feraloy® iron alloy body
• Heavy-gauge steel – cover and mounting
straps
• Neoprene gaskets
Standard Finishes:
• Feraloy iron alloy and heavy-gauge steel
– hot-dip galvanized
Options:
Description
Factory installed mounting plate
Suffix
-MP
See Ordering Information, beginning
pg. 164, for:
Drilled and tapped conduit holes
Slip holes
•
•
•
•
•
UL Standard: 50
CSA Standard C22.2
Weatherproof
Watertight
CEC:
Class II, E, F, G
Class III
Encl. 3 – 4
• H20 Vehicle Load Rating*
*Self certify to H20 vehicle load rating equivalent to
16,000 lbs. on cover center.
Size Ranges:
• 4" x 4" x 3" to 36" x 24" x 24"
Wall
Thickness (in.)
Length
(in.)
Width
(in.)
Depth
(in.)
1/ 4
4
4
6
6
6
8
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
14
14
16
16
16
18
18
18
18
18
18
18
18
18
18
18
18
24
24
24
24
24
24
24
24
24
30
30
36
36
4
4
4
6
6
6
6
8
8
8
8
8
10
10
6
8
8
8
12
12
12
12
8
14
12
12
16
8
8
10
12
12
12
12
12
18
18
18
18
12
12
18
18
18
18
24
24
24
24
24
24
24
3
4
4
4
6
4
6
4
6
8
6
8
6
8
6
6
8
10
6
8
12
18
6
10
6
8
6
6
8
6
6
8
10
12
18
6
8
12
18
8
12
8
10
12
18
12
18
24
12
18
18
24
WJB040403
WJB040404✓
WJB060404
WJB060604✓
WJB060606✓
WJB080604
WJB080606✓
WJB080804✓
WJB080806
WJB080808
WJB100806
WJB100808
WJB101006✓
WJB101008
WJB120606
WJB120806
WJB120808
WJB120810
WJB121206✓
WJB121208✓
WJB121212
WJB121218
WJB140806
WJB141410
WJB161206
WJB161208
WJB161606
WJB180806
WJB180808
WJB181006
WJB181206
WJB181208✓
WJB181210
WJB181212
WJB181218
WJB181806
WJB181808
WJB181812
WJB181818
WJB241208
WJB241212
WJB241808
WJB241810
WJB241812
WJB241818
WJB242412
WJB242418
WJB242424
WJB302412
WJB302418
WJB362418
WJB362424
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
5/ 16
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
9/ 16
9/ 16
9/ 16
9/ 16
9/ 16
9/ 16
9/ 16
9/ 16
Junction Boxes
Certifications and
Compliances:
Cat. #
✓ – available with Lightning Service™
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
161
Weatherproof
Watertight
Raintight
NEMA 3, 4
WJBF Checkered Cover
Sidewalk Junction Boxes
Heavy Duty
External Flanged for Flush Mounting
Applications:
WJB boxes are standard with mounting
straps and are primarily designed for
surface mounting. WJB heavy duty junction
boxes are installed in conduit systems to:
• Act as pull box for conductors
• Provide openings and space for making
splices and taps in conductors
• Provide for branch conduit runs
• Provide access to conductors for
maintenance and future system changes
• Enclose and protect electrical equipment
Features:
• Covers are suitable for vehicular traffic
(H20 loading)
• Neoprene gasket cemented to cover
• Wide range of drilled and tapped conduit
entrance sizes and locations permits
extreme flexibility of use in conduit
system
• Internal equipment mounting pads may
be drilled and tapped for 1/ 4" – 20
mounting screws
• Blind tapped into internal mounting pads
Standard Materials:
• Feraloy® iron alloy body
• Heavy-guage Steel (checkered) – cover,
mounting straps
• Neoprene gaskets
Standard Finishes:
• Feraloy iron alloy and heavy-gauge steel
– hot-dip galvanized
Options:
Description
Factory installed mounting plate
Suffix
-MP
Junction Boxes
See Ordering Information, beginning
pg. 164, for:
Drilled and tapped conduit holes
Slip holes
Size Ranges:
• 4" x 4" x 4" to 36" x 24" x 24"
Certifications and
Compliances:
•
•
•
•
•
UL Standard: 50
CSA Standard C22.2 No. 40
Weatherproof
Watertight
CEC:
Class II, Division 1, Groups E, F, G
Class III
Encl. 3, 4
• H20 Vehicle Load Rating*
*Self certify to H20 vehicle load rating equivalent to
16,000 lbs. on cover center.
162
Cat. #
WJBF040404✓
WJBF060404✓
WJBF060604✓
WJBF060606✓
WJBF080604✓
WJBF080606✓
WJBF080804✓
WJBF080806✓
WJBF080808✓
WJBF100806
WJBF100808
WJBF101006✓
WJBF101008✓
WJBF120606
WJBF120806
WJBF120808✓
WJBF120810
WJBF121206✓
WJBF121208✓
WJBF121212✓
WJBF121218
WJBF140806
WJBF141410
WJBF161206
WJBF161208✓
WJBF161606
WJBF180806
WJBF180808
WJBF181006
WJBF181206
WJBF181208✓
WJBF181210
WJBF181212
WJBF181218
WJBF181806
WJBF181808
WJBF181812✓
WJBF181818
WJBF241208
WJBF241212
WJBF241808
WJBF241810✓
WJBF241812
WJBF241818
WJBF242412
WJBF242418
WJBF242424
WJBF302412
WJBF302418
WJBF362418
WJBF362424
Wall
Thickness (in.)
Length
(in.)
Width
(in.)
Depth
(in.)
1/ 4
4
6
6
6
8
8
8
8
8
10
10
10
10
12
12
12
12
12
12
12
12
14
14
16
16
16
18
18
18
18
18
18
18
18
18
18
18
18
24
24
24
24
24
24
24
24
24
30
30
36
36
4
4
6
6
6
6
8
8
8
8
8
10
10
6
8
8
8
12
12
12
12
8
14
12
12
16
8
8
10
12
12
12
12
12
18
18
18
18
12
12
18
18
18
18
24
24
24
24
24
24
24
4
4
4
6
4
6
4
6
8
6
8
6
8
6
6
8
10
6
8
12
18
6
10
6
8
6
6
8
6
6
8
10
12
18
6
8
12
18
8
12
8
10
12
18
12
18
24
12
18
18
24
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
5/ 16
1/ 4
1/ 4
5/ 16
5/ 16
1/ 4
5/ 16
1/ 4
1/ 4
1/ 4
1/ 4
1/ 4
5/ 16
5/ 16
5/ 16
3/ 8
5/ 16
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
3/ 8
✓ – available with Lightning Service™
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
WEB Junction Box
Heavy Duty
Internal Recess Flange for Flush Mounting
Dust-tight
Raintight
NEMA 3
Applications:
WEB Junction Boxes are installed:
• Where a heavy duty, dust-tight or raintight
enclosure is desired
• To act as pull box for conductors
• To provide openings and space for
making splices and taps in conductors
• To provide for branch conduit runs
• To provide access to conductors for
maintenance and future system changes
• To enclose and protect electrical devices
Features:
• Flat neoprene gasket cemented to cover
• Internal equipment mounting pads
• Standard attachable heavy-gauge steel
straps for mounting box
• Stainless-steel cover screws
• Internal ground screw
• Optional drilled and tapped conduit
entries or slip holes
• Optional mounting plate
Standard Materials:
• Body – Feraloy® iron alloy, hot dip
galvanized
• Cover – heavy-gauge steel, hot dip
galvanized
• Cover screws – stainless steel
• Mounting Strap – heavy-gauge steel,
electrogalvanized
• Gasket – neoprene
Cat. #
WEB040403
WEB040404
WEB060604
WEB060606
WEB080804
WEB080806
WEB121206
WEB160606
WEB160806
WEB180808
WEB240606
WEB240808
WEB241010
WEB241210
WEB241212
WEB241812
WEB361212
WEB361812
WEB362412
WEB363612
Wall
Thickness (in.)
Length
(in.)
Width
(in.)
Depth
(in.)
7/ 32
4
4
6
6
8
8
12
16
16
18
24
24
24
24
24
24
36
36
36
36
4
4
6
6
8
8
12
6
8
8
6
8
10
12
12
18
12
18
24
36
3
4
1/ 4
9/ 32
1/ 4
9/ 32
1/ 4
9/ 32
9/ 32
1/ 4
5/ 16
9/ 32
5/ 16
3/ 8
5/ 16
5/ 16
3/ 8
3/ 8
3/ 8
7/ 16
7/ 16
6
4
6
6
6
6
8
6
8
10
10
12
12
12
12
12
12
Certifications and
Compliances:
• UL Standard 50
• CSA certified C22.2
Options:
Description
Suffix
All boxes are available with optional
-MP
mounting plate
Junction Boxes
See Ordering Information, beginning
pg. 164, for:
Drilled and tapped conduit holes
Slip holes
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
163
W Series Junction Boxes
Ordering Information
DRILLED AND TAPPED CONDUIT OPENINGS OR SLIP HOLES
All W-Series cast-iron junction boxes may be ordered with drilled and tapped conduit openings or slip holes – subject to minimum spacing
limitations listed in Table 1.
To order a box from the factory with conduit openings:
Option 1:
Table 1
Send in a sketch of the box with openings
specified (subject to spacing limitations
specified in Table 1). OR
Minimum spacing between centers of conduits
1/ 2"
Option 2:
Step 1: Select one of the four standard
arrangements in Table 2, based
on number and location of conduit
entries.
Step 2: Pick a symbol from Table 3 for
each opening in the arrangement
(see example).
Step 3: Table 4 lists the maximum size
and number of conduit openings
by box size and the spacing
dimensions. Use Table 4 to verify
the openings selected are
permitted.
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
6"
5"
4"
31/2"
5
51/ 8
51/ 4
51/ 2
55/ 8
6
61/ 4
65/ 8
7
71/ 4
8
85/ 8
43/ 8
35/ 8
33/ 8
41/ 2
45/ 8
47/ 8
5
53/ 8
55/ 8
6
61/ 4
65/ 8
71/ 4
33/ 4
4
41/ 8
41/ 4
45/ 8
47/ 8
53/ 8
55/ 8
57/ 8
31/ 2
35/ 8
37/ 8
4
41/ 4
45/ 8
5
51/ 4
3"
21/2"
2"
3
31/ 8
31/ 4
31/ 2
35/ 8
37/ 8
41/ 4
45/ 8
25/ 8
23/ 8
23/ 4
3
31/ 8
31/ 4
35/ 8
37/ 8
21/ 2
25/ 8
27/ 8
3
31/ 4
11/2"
11/4"
1"
3/ 4"
1/ 2"
2
21/ 8
23/ 8
21/ 2
25/ 8
17/ 8
13/ 4
15/ 8
11/ 2
2
21/ 4
23/ 8
2
17/ 8
13/ 4
Table 2
Example – Catalog
number logic:
Standard conduit arrangements
1. Select box required: WAB121208.
2. User wants one 1/ 2" drilled and tapped
hole in the top of the box, two 1" drilled
and tapped holes on both sides and
three 1/ 2" slip holes in the bottom of the
box.
3. Select arrangement 3 because it allows
up to three openings per side.
4. Next the symbols for the openings are
substituted and written in clockwise
order starting with location "a". The
catalog number is written in three parts;
part 1 – box number, part 2 –
arrangement number, part 3 – symbols
for the conduit openings.
5. For this example the box would be
ordered as:
Junction Boxes
Size of
Conduit
Table 3
Symbols for openings
Conduit
Size
Drilled and
Tapped Hole
Slip
Hole
A
B
C
E
F
G
H
J
K
L
M
N
0 (Zero)
1A
1B
1C
1E
1F
1G
1H
1J
1K
1L
1M
1N
0 (Zero)
1/ 2"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
5"
6"
None
S = Dimension from wall
to hole center line
164
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
W Series Junction Boxes
Ordering Information
DRILLED AND TAPPED CONDUIT OPENINGS OR SLIP HOLES
Table 4
Maximum Size and Number of Drilled and Tapped Conduit
Openings
Top and Bottom†
Sides
W Series
Cat. #
040402
040403
040404
050503
050504
Spacing Dimensions*
1
2
3
4
1
2
3
4
s
t
u
v
w
x
y
3/ 4
3/ 4
—
—
—
—
—
—
—
—
—
—
3/ 4
3/ 4
—
—
—
—
—
—
—
—
—
—
11/ 4
15/ 8
21/ 4
15/ 8
21/ 4
7/ 8
7/ 8
7/ 8
11/ 4
11/ 4
7/ 8
11/ 4
11/ 4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
7/ 8
—
—
13/ 4
13/ 4
13/ 4
—
—
—
—
—
—
—
—
—
—
11/ 4
2
11/ 4
2
3/ 4
3/ 4
3/ 4
1
11/ 4
2
11/ 4
2
3/ 4
3/ 4
3/ 4
1
7/ 8
7/ 8
2
11/ 4
2
4
3/ 4
3/ 4
11/ 4
11/ 2
11/ 2
—
—
3/ 4
3/ 4
3/ 4
—
—
—
—
—
15/ 8
21/ 4
11/ 4
21/ 4
33/ 8
13/ 8
13/ 8
13/ 8
13/ 8
13/ 8
13/ 8
13/ 8
13/ 8
13/ 4
13/ 4
13/ 4
13/ 4
13/ 4
1
1
1
1
1
3/ 4
11/ 4
2
4
3
4
3/ 4
11/ 2
11/ 2
2
2
—
3/ 4
3/ 4
1
1
—
—
—
3/ 4
3/ 4
15/ 8
21/ 4
33/ 8
21/ 4
33/ 8
15/ 8
15/ 8
15/ 8
15/ 8
15/ 8
7/ 8
13/ 8
13/ 8
15/ 8
15/ 8
21/ 2
21/ 2
21/ 2
21/ 2
21/ 2
—
13/ 4
13/ 4
21/ 2
21/ 2
—
13/ 4
13/ 4
13/ 4
13/ 4
—
—
—
13/ 4
13/ 4
2
11/ 4
2
2
3
1
11/ 2
11/ 2
11/ 2
11/ 2
3/ 4
4
2
2
2
4
2
11/ 2
11/ 2
2
2
1
1
1
1
1
3/ 4
—
—
3/ 4
2/ 4
41/ 4
21/ 4
21/ 4
21/ 4
33/ 8
15/ 8
21/ 4
21/ 2
21/ 2
21/ 2
15/ 8
13/ 8
13/ 8
15/ 8
15/ 8
21/ 2
3
23/ 4
23/ 4
23/ 4
21/ 2
13/ 4
13/ 4
21/ 2
13/ 4
13/ 4
2
21/ 2
21/ 2
21/ 2
13/ 4
—
—
13/ 4
13/ 4
5
4
5
2
4
3
3
3
2
4
11/ 2
11/ 2
11/ 2
2
21/ 2
1
1
1
11/ 2
11/ 2
5
3
5
2
4
2
3
3
11/ 2
11/ 2
1
11/ 2
11/ 2
3/ 4
3/ 4
3/ 4
41/ 2
23/ 8
41/ 4
21/ 4
33/ 8
21/ 2
21/ 2
21/ 2
3
3
15/ 8
21/ 2
21/ 2
13/ 8
13/ 8
23/ 4
23/ 4
23/ 4
4
4
21/ 2
23/ 4
23/ 4
13/ 4
13/ 4
21/ 2
21/ 2
21/ 2
23/ 4
23/ 4
13/ 4
21/ 2
21/ 2
—
—
120806
120808
121204
121206
121208
4
5
2
4
5
4
4
2
4
4
21/ 2
21/ 2
2
21/ 2
21/ 2
21/ 2
21/ 2
11/ 2
11/ 2
11/ 2
4
5
2
4
5
2
2
2
4
4
1
1
2
21/ 2
21/ 2
11/ 2
11/ 2
11/ 2
33/ 8
41/ 4
21/ 4
33/ 8
41/ 4
3
3
3
3
3
15/ 8
15/ 8
3
3
3
4
4
4
4
4
21/ 2
21/ 2
4
4
4
23/ 4
23/ 4
23/ 4
23/ 4
23/ 4
13/ 4
11/ 4
23/ 4
23/ 4
23/ 4
121212
121218
140806
141206
141410
6
6
4
4
6
4
4
4
4
4
21/ 2
21/ 2
3
3
3
11/ 2
11/ 2
2
2
2
6
6
4
4
6
4
4
2
4
4
21/ 2
21/ 2
1
21/ 2
3
11/ 2
11/ 2
3/ 4
11/ 2
2
5
5
33/ 8
33/ 8
5
3
3
31/ 2
31/ 2
31/ 2
3
3
15/ 8
3
31/ 2
4
4
41/ 2
41/ 2
41/ 2
4
4
21/ 2
4
41/ 2
23/ 4
23/ 4
31/ 2
31/ 2
31/ 2
23/ 4
23/ 4
13/ 4
23/ 4
31/ 2
160606
160806
161206
161208
161606
4
4
4
5
4
4
4
4
5
4
31/ 2
31/ 2
31/ 2
31/ 2
31/ 2
21/ 2
21/ 2
21/ 2
21/ 2
21/ 2
4
4
4
5
4
11/ 2
21/ 2
4
4
4
3/ 4
11/ 2
21/ 2
21/ 2
31/ 2
—
3/ 4
11/ 2
11/ 2
21/ 2
33/ 8
33/ 8
33/ 8
41/ 4
33/ 8
4
4
4
4
4
11/ 2
2
3
3
4
53/ 8
53/ 8
53/ 8
53/ 8
53/ 8
2
25/ 8
4
4
53/ 8
4
4
4
4
4
—
2
3
3
4
180806
180808
181206
181208
181210
4
5
4
5
6
4
5
4
5
5
4
4
4
4
4
21/ 2
21/ 2
21/ 2
21/ 2
21/ 2
4
5
4
5
6
21/ 2
21/ 2
4
4
4
11/ 4
11/ 4
21/ 2
21/ 2
21/ 2
3/ 4
33/ 8
41/ 4
33/ 8
41/ 4
5
41/ 2
41/ 2
61/ 2
41/ 2
41/ 4
2
2
27/ 8
3
3
6
6
51/ 2
51/ 2
51/ 2
25/ 8
25/ 8
37/ 8
4
4
41/ 2
41/ 2
4
4
4
2
2
23/ 4
23/ 4
23/ 4
060403
060404
060603
060604
060606
11/ 4
2
11/ 4
2
4
3/ 4
11/ 4
11/ 2
11/ 2
080403
080604
080606
080804
080806
11/ 4
2
4
2
4
11/ 4
2
2
2
2
080808
090604
100604
100804
100806
4
2
2
2
4
100808
101006
101008
120604
120606
11/ 2
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
3/ 4
1
1
1
1
—
—
3/ 4
3/ 4
3/ 4
11/ 2
11/ 2
11/ 2
7/ 8
Junction Boxes
—
—
—
—
—
11/ 4
*Spacing dimensions apply to drilled and tapped holes. Space has been provided for a locknut and bushing when drilled and tapped holes are required.
†Top and bottom are the longer dimensions on enclosures which are not square.
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
165
W Series Junction Boxes
Ordering Information
DRILLED AND TAPPED CONDUIT OPENINGS OR SLIP HOLES
Table 4 (continued)
Maximum Size and Number of Drilled and Tapped Conduit
Openings
Top and Bottom†
Sides
Spacing Dimensions*
W Series
Cat. #
1
2
3
4
3
4
u
v
w
x
y
5
5
4
5
6
4
4
4
4
4
21/ 2
21/ 2
21/ 2
21/ 2
21/ 2
4
4
5
5
6
21/ 2
21/ 2
4
31/ 2
4
11/ 2
11/ 2
21/ 2
21/ 2
21/ 2
s
5
5
33/ 8
41/ 4
5
t
6
6
4
5
6
1
6
6
5
5
6
2
181212
181218
181806
181808
181812
41/ 2
41/ 2
41/ 2
41/ 2
41/ 2
3
3
4
4
41/ 2
51/ 2
51/ 2
6
6
6
4
4
53/ 8
53/ 8
6
4
4
41/ 2
41/ 2
41/ 2
21/ 4
23/ 4
4
4
41/ 2
240606
240808
241010
241208
241210
4
5
6
5
6
4
5
6
5
6
4
5
5
5
5
4
4
4
4
4
4
5
6
5
6
11/ 2
21/ 2
3
4
4
3/ 4
11/ 2
21/ 2
21/ 2
—
3/ 4
1
11/ 2
11/ 2
33/ 8
41/ 4
5
41/ 4
5
63/ 4
63/ 4
61/ 2
61/ 2
61/ 2
13/ 8
41/ 2
21/ 2
27/ 8
3
8
8
7
7
7
13/ 4
25/ 8
23/ 4
37/ 8
4
6
6
53/ 4
53/ 4
53/ 4
—
2
21/ 2
23/ 4
23/ 4
241212
241808
241810
241812
242408
6
5
6
6
5
6
5
6
6
5
5
5
5
5
5
4
4
4
4
4
6
5
6
6
5
4
5
6
5
5
21/ 2
4
4
4
5
11/ 2
21/ 2
21/ 2
21/ 2
4
5
41/ 4
5
5
41/ 4
61/ 2
61/ 2
61/ 2
61/ 2
61/ 2
27/ 8
41/ 2
41/ 2
41/ 2
61/ 2
7
7
7
7
7
37/ 8
53/ 4
53/ 4
53/ 4
71/ 2
53/ 4
53/ 4
53/ 4
53/ 4
53/ 4
23/ 4
4
4
4
53/ 4
242412
242424
302412
361212
361812
6
6
6
6
6
6
6
6
6
6
5
5
6
6
6
4
4
5
6
6
6
6
6
6
6
6
6
6
4
5
5
5
5
21/ 2
4
4
4
4
11/ 2
21/ 2
5
61/ 2
5
5
5
61/ 2
63/ 4
71/ 2
83/ 4
83/ 4
61/ 2
61/ 2
63/ 4
3
41/ 2
7
7
10
12
12
71/ 2
71/ 2
8
4
41/ 2
53/ 4
53/ 4
71/ 2
9
9
53/ 4
53/ 4
6
23/ 4
4
362412
363612
6
6
6
6
6
6
6
6
6
6
6
6
5
6
4
6
5
5
83/ 4
83/ 4
63/ 4
83/ 4
12
12
8
12
9
9
6
9
11/ 4
Junction Boxes
*Spacing dimensions apply to drilled and tapped holes. Space has been provided for a locknut and bushing when drilled and tapped holes are required.
†Top and bottom are the longer dimensions on enclosures which are not square.
166
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Watertight
Corrosion-Resistant
XD Expansion/Deflection Coupling
Applications:
Standard Finishes:
XD couplings can be installed indoors,
outdoors, buried underground, or
embedded in concrete in non-hazardous
areas. XD’ s are used with standard rigid
conduit or PVC rigid conduit. (PVC requires
rigid metal conduit nipples and rigid metalto-PVC conduit adapters.) XD’ s provide a
flexible and watertight connection for
protection of conduit wiring systems from
damage due to movement.
Typical applications include:
• Underground conduit feeder runs
• Runs between sections of concrete
subject to relative movement
• Runs between fixed structures
• Conduit entrances in high-rise buildings
• Bridges
• Marinas, docks, piers
• Feraloy – electrogalvanized
• Neoprene – natural (black)
• Molded plastic – natural (brown)
Features:
• UL standards: 514B
Size Ranges:
• 1" to 6" (Smaller sizes can be obtained
by using reducing bushings)
1. Axial expansion/contraction.
XD
Inches
Hub Size
Cat. #
1
11/ 4
11/ 2
2
21/ 2
XD3
XD4
XD5
XD6
XD7
Hub Size
Cat. #
3
31/ 2
4
5
6
XD8
XD9
XD010
XD012
XD014
2. Angular misalignment.
Dimensions
In Inches:
Hub Size
1
11/ 4
11/ 2
2
21/ 2
3
31/ 2
4
5
6
a
b
7
73/ 8
71/ 4
71/ 4
71/ 2
75/ 8
73/ 4
77/ 8
73/ 4
83/ 8
315/ 16
41/ 4
41/ 2
415/ 16
55/ 16
515/ 16
61/ 2
615/ 16
8
9
3. Parallel misalignment.
Junction Box Accessories
• XD couplings accommodate the following
movements without collapsing or
fracturing the conduit, and damaging the
wires it contains:
1. Axial expansion or contraction up to
3/ 4"
2. Angular misalignment of the axes of
the coupled conduit runs in any
direction to 30°
3. Parallel misalignment of the axes of
coupled conduit runs in any direction
to 3/ 4"
• Inner sleeve maintains constant I.D. in
any position and provides a smooth
insulated wireway for protection of wire
insulation
• Watertight flexible neoprene outer jacket
is corrosion resistant and protects the
grounding strap and the attachment
points of the hubs
• Tinned copper flexible braid grounding
straps assure grounding continuity
• Stainless steel jacket clamps for strength
and corrosion resistance
• Standard tapered electrical threads fit
standard rigid conduit
• Integral hub bushing protects insulation of
conductors
Certifications and
Compliances:
Standard Materials:
•
•
•
•
•
Hubs – Feraloy® iron alloy
Outer jacket – molded neoprene
Jacket clamps – stainless steel
Inner sleeve – molded plastic
Grounding straps – tinned copper flexible
braid
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
167
XJG Conduit Expansion Joints
With Internal Grounding
For Rigid Metal Conduit and IMC
Wet Locations
Applications:
XJG expansion couplings are used with
rigid metal conduit and IMC:
• Without the need for an external bonding
jumper and clamps (up to 4")
• To couple together two (2) sections of
conduit subject to longitudinal movement
• In long conduit runs to permit linear
movement caused by thermal expansion
and contraction
• On long conduit runs to prevent conduit
from buckling and ensuing circuit failures
• Indoors or outdoors where conduit
expansion occurs and there are wide
temperature ranges
• In conduit runs that cross structural joints
• In conduit runs to prevent damage to
conduit supports such as in a building or
on a bridge
• With optional redundant visible grounding
strap
Junction Box Accessories
Standard Materials and
Finishes:
Body
• Steel – electrogalvanized
• Copper-free aluminum – natural
• Feraloy® iron alloy – electrogalvanized (5"
+ 6" only)
Reducer
• 1/ 2" through 1" – Steel – electrogalvanized
• 11/ 4" through 6" – Feraloy® iron alloy –
electrogalvanized and aluminum paint
• Copper-free aluminum – natural
Gland Nut
• 1/ 2" through 1" – Steel – electrogalvanized
• 11/ 4" through 6" – Feraloy® iron alloy –
electrogalvanized and aluminum paint
• Copper–free aluminum – natural
Packing
• Teflon® (trademark of E.I. DuPont Co.)
Washer
• Steel – electrogalvanized
• Copper-free aluminum – natural
Gasket
• Vellum
Bushing
• 1/ 2" through 1" – Steel – electrogalvanized
• 11/ 4" through 6" – Feraloy® iron alloy –
electrogalvanized and aluminum paint
• Copper-free aluminum – natural
Ground Springs
• Phosphor bronze – electrogalvanized
Ground Strap
• Braided tinned copper
U-Bolts
• Malleable iron – electrogalvanized
168
Patent Pending*
XJG – For use with rigid metal conduit and IMC
Maximum
Conduit
Movement
Cat. #
Optional
Bonding
Jumper
A
Diameter
B
Length
Bonding
Jumper
Length
1/ 2
4
8
XJG14
XJG18
BJ14
BJ18
1.75
1.75
6.75
10.75
20"
30"
3/ 4
4
8
XJG24
XJG28
BJ24
BJ28
2.12
2.12
6.75
10.75
20"
30"
1
4
8
XJG34
XJG38
BJ34
BJ38
2.43
2.43
7.25
11.25
20"
30"
11/ 4
4
8
XJG44
XJG48
BJ44
BJ48
3.19
3.19
7.56
11.56
24"
30"
11/ 2
4
8
XJG54
XJG58
BJ54
BJ58
3.68
3.68
7.87
11.87
24"
30"
2
4
8
XJG64
XJG68
BJ64
BJ68
4.75
4.75
8.25
12.25
24"
30"
21/ 2
4
8
XJG74
XJG78
BJ74
BJ78
4.87
4.87
9.31
13.31
24"
36"
3
4
8
XJG84
XJG88
BJ84
BJ88
5.37
5.37
10.00
14.00
30"
36"
31/ 2
4
8
XJG94
XJG98
BJ94
BJ98
6.62
6.62
9.81
13.81
30"
36"
4
4
8
XJG104
XJG108
BJ104
BJ108
6.62
6.62
9.81
13.81
30"
36"
5
8
XJ128‡
—
7.64
15.50
—
6
8
XJ148‡
—
9.56
16.00
—
Conduit
Size
*Teflon® is a registered trademark of E.I. DuPont Co.
‡XJ128 and XJ148 are not internally grounded. A pair of 36" bonding jumpers are provided with fitting.
Options:
Description
Suffix
Available in copper-free aluminum
SA
Available with redundant ground strap
for visible indication of grounding –
order separately (BJ Series)†
†XJG expansion couplings use a metallic bushing and
ground springs to create a high integrity internal ground
connection. External ground straps offer a redundant
ground path and easy visible indication of ground
Size Ranges:
• 1/ 2" through 6" conduit size
• 4" and 8" maximum conduit movement
Certifications and
Compliances:
•
•
•
•
•
XJG shown with optional bonding
jumper
UL Standard: 514B
CSA Standard: C22.2 No. 18
NEC Articles 250-77 and 300-7 (b)
NEMA FB1
Wet Locations
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
XJG-EMT Conduit Expansion Joints
With Internal Grounding
For EMT Conduit
Applications:
XJG expansion couplings are used with
EMT Conduit:
• Without the need for an external bonding
jumper and clamps
• To couple together two (2) sections of
conduit subject to longitudinal movement
• In long conduit runs to permit linear
movement caused by thermal expansion
and contraction
• On long conduit runs to prevent conduit
from buckling and ensuing circuit failures
• Indoors or outdoors where conduit
expansion occurs and there are wide
temperature ranges
• In conduit runs that cross structural joints
• In conduit runs to prevent damage to
conduit supports such as in a building or
on a bridge
• With optional redundant visible grounding
strap
XJG – For use with rigid metal conduit and IMC
Conduit
Size
1/ 2"
Maximum
Conduit
Movement
4"
4"
4"
4"
4"
4"
4"
4"
4"
4"
3/ 4"
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Cat. #
Optional
Bonding
Jumper
XJG14 EMT
XJG24 EMT
XJG34 EMT
XJG44 EMT
XJG54 EMT
XJG64 EMT
XJG74 EMT
XJG84 EMT
XJG94 EMT
XJG104 EMT
BJ14
BJ24
BJ34
BJ44
BJ54
BJ64
BJ74
BJ84
BJ94
BJ104
A
Diameter
B
Length
13/ 4"
21/ 8"
27/ 16"
31/ 8"
35/ 8"
43/ 4"
47/ 8"
53/ 8"
65/ 8"
65/ 8"
103/ 4"
11"
111/ 2"
151/ 4"
151/ 2"
151/ 2"
183/ 4"
197/ 8"
211/ 4"
211/ 4"
Standard Materials and
Finishes:
XJG shown with optional bonding jumper
*Teflon® is a registered trademark of E.I. DuPont Co.
Options:
Size Ranges:
Description
Available with redundant ground strap for
visible indication of grounding – order
separately (BJ Series)†
• 1/ 2" through 4" conduit size
• 4" maximum conduit movement
†XJG expansion couplings use a metallic bushing and
ground springs to create a high integrity internal ground
connection. External ground straps offer a redundant
ground path and easy visible indication of ground
US: 1-866-764-5454
CAN: 1-800-265-0502
Certifications and
Compliances:
•
•
•
•
Junction Box Accessories
Body
• Steel – electrogalvanized
• Copper-free aluminum – natural
Reducer
• 1/ 2" through 1" – Steel – electrogalvanized
• 11/ 4" through 4" – Feraloy® iron alloy –
electrogalvanized and aluminum paint
Gland Nut
• 1/ 2" through 1" – Steel – electrogalvanized
• 11/ 4" through 4" – Feraloy® iron alloy –
electrogalvanized and aluminum paint
Packing
• Teflon® (trademark of E.I. DuPont Co.)
Washer
• Steel – electrogalvanized
Gasket
• Vellum
Bushing
• 1/ 2" through 1" – Steel – electrogalvanized
• 11/ 4" through 4" – Feraloy® iron alloy –
electrogalvanized and aluminum paint
Ground Springs
• Phosphor bronze – electrogalvanized
Ground Strap
• Braided tinned copper
U-Bolts
• Malleable iron – electrogalvanized
UL Standard: 514B
CSA Standard: C22.2 No. 18
NEC Articles 250-77 and 300-7 (b)
NEMA FB1
Copyright© 2007 Cooper Crouse-Hinds
169
Wet Locations
XJGD Combination
Expansion/Deflection Coupling
and Expansion Joint
Internally Grounded
Applications:
XJGD combination fittings are used with
rigid metal conduit and IMC:
• To accommodate axial expansion,
angular misalignment and parallel
misalignment
• To couple together two (2) sections of
conduit subject to longitudinal movement
• To maintain a ground connection without
the need for an external bonding jumper
and clamps
• In long conduit runs to prevent conduit
from buckling and causing circuit failures
• Indoors or outdoors where conduit
expansion occurs and there are wide
temperature swings
• In conduit runs that cross structural joints
• In conduit runs to prevent damage to
conduit supports such as in a building or
on a bridge
Hub Size
1"
11/ 4"
11/ 2"
2"
21/ 2"
3"
31/ 2"
4"
Maximum
Conduit
Movement
4"
4"
4"
4"
4"
4"
4"
4"
Cat. #
XJGD34
XJGD44
XJGD54
XJGD64
XJGD74
XJGD84
XJGD94
XJGD104
Standard Materials:
• Body, Hubs, Gland Nut, Washer, Bushing
– Feraloy®
• Packing – Teflon®
• Gasket – vellum
• Ground Spring – phosphor bronze
• Outer Jacket – molded neoprene
• Jacket Clamps – stainless steel
• Inner Sleeve – molded plastic
• Ground Straps – tinned copper braid
Standard Finishes:
• Feraloy® – electrogalvanized
Certifications and
Compliances:
Junction Box Accessories
• UL Standard: 514B
170
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
A
Diameter
B
Length
315/ 16"
41/ 4"
41/ 2"
415/ 16"
55/ 16"
515/ 16"
61/ 2"
8"
173/ 4"
181/ 8"
185/ 8"
191/ 4"
203/ 4"
215/ 8"
215/ 8"
273/ 4"
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
0B . . . . . . . . . . . . . . . . . . . . . . .111
10 . . . . . . . . . . . . . . . . . . . . . . .100
1031 . . . . . . . . . . . . . . . . . . . . .100
1031NI . . . . . . . . . . . . . . . . . . .100
1032 . . . . . . . . . . . . . . . . . . . . .100
1032NI . . . . . . . . . . . . . . . . . . .100
1453 . . . . . . . . . . . . . . . . . . . . . .91
1453DC . . . . . . . . . . . . . . . . . . .92
1454 . . . . . . . . . . . . . . . . . . . . . .91
1454DC . . . . . . . . . . . . . . . . . . .92
1455 . . . . . . . . . . . . . . . . . . . . . .91
1455DC . . . . . . . . . . . . . . . . . . .92
1655 . . . . . . . . . . . . . . . . . . . . . .89
1655DC . . . . . . . . . . . . . . . . . . .92
1655RT . . . . . . . . . . . . . . . . . . . .89
1656 . . . . . . . . . . . . . . . . . . . . . .89
1656DC . . . . . . . . . . . . . . . . . . .92
1656RT . . . . . . . . . . . . . . . . . . . .89
1744DC . . . . . . . . . . . . . . . . . . .147
1745 . . . . . . . . . . . . . . . . . . . . .147
1745DC . . . . . . . . . . . . . . . . . . .147
1746 . . . . . . . . . . . . . . . . . . . . .147
1746DC . . . . . . . . . . . . . . . . . . .147
1747 . . . . . . . . . . . . . . . . . . . . .147
1033 . . . . . . . . . . . . . . . . . . . . .100
1033NI . . . . . . . . . . . . . . . . . . .100
1034 . . . . . . . . . . . . . . . . . . . . .100
1034NI . . . . . . . . . . . . . . . . . . .100
1035 . . . . . . . . . . . . . . . . . . . . .100
1035NI . . . . . . . . . . . . . . . . . . .100
1456 . . . . . . . . . . . . . . . . . . .91, 97
1456DC . . . . . . . . . . . . . . . . . . .92
1457 . . . . . . . . . . . . . . . . . . .91, 97
1457DC . . . . . . . . . . . . . . . . . . .92
1458 . . . . . . . . . . . . . . . . . . .91, 97
1458DC . . . . . . . . . . . . . . . . . . .92
1657 . . . . . . . . . . . . . . . . . . . . . .89
1657DC . . . . . . . . . . . . . . . . . . .92
1657RT . . . . . . . . . . . . . . . . . . . .89
1658 . . . . . . . . . . . . . . . . . . . . . .89
1658DC . . . . . . . . . . . . . . . . . . .92
1658RT . . . . . . . . . . . . . . . . . . . .89
1747DC . . . . . . . . . . . . . . . . . . .147
17DC . . . . . . . . . . . . . . . . . . . .100
17X . . . . . . . . . . . . . . . . . . . . . .100
18 . . . . . . . . . . . . . . . . . . . . . . .100
18 SA . . . . . . . . . . . . . . . . . . . .100
188 . . . . . . . . . . . . . . . . . . . . . .106
1036 . . . . . . . . . . . . . . . . . . . . .100
1036NI . . . . . . . . . . . . . . . . . . .100
1037 . . . . . . . . . . . . . . . . . . . . .100
1037NI . . . . . . . . . . . . . . . . . . .100
1038 . . . . . . . . . . . . . . . . . . . . .100
1038NI . . . . . . . . . . . . . . . . . . .100
1459 . . . . . . . . . . . . . . . . . . .91, 97
1459DC . . . . . . . . . . . . . . . . . . .92
14DC . . . . . . . . . . . . . . . . . . . .100
14X . . . . . . . . . . . . . . . . . . . . . .100
15 . . . . . . . . . . . . . . . . . . . . . . .100
15 SA . . . . . . . . . . . . . . . . . . . .100
1659 . . . . . . . . . . . . . . . . . . . . . .89
1659DC . . . . . . . . . . . . . . . . . . .92
1659RT . . . . . . . . . . . . . . . . . . . .89
16DC . . . . . . . . . . . . . . . . . . . .100
16X . . . . . . . . . . . . . . . . . . . . . .100
17 . . . . . . . . . . . . . . . . . . . . . . .100
189 . . . . . . . . . . . . . . . . . . . . . .106
18DC . . . . . . . . . . . . . . . . . . . .100
18X . . . . . . . . . . . . . . . . . . . . . .100
19 . . . . . . . . . . . . . . . . . . . . . . .100
19 SA . . . . . . . . . . . . . . . . . . . .100
190M . . . . . . . . . . . . . . . . . . . . .106
1039 . . . . . . . . . . . . . . . . . . . . .100
1039NI . . . . . . . . . . . . . . . . . . .100
1040 . . . . . . . . . . . . . . . . . . . . .100
1040NI . . . . . . . . . . . . . . . . . . .100
1041 . . . . . . . . . . . . . . . . . . . . .100
1042 . . . . . . . . . . . . . . . . . . . . .100
150 . . . . . . . . . . . . . . . . . .116, 117
150P . . . . . . . . . . . . . . . . . . . . . .97
150S . . . . . . . . . . . . . . . . . . . . . .97
151 . . . . . . . . . . . . . . . . . . . . . . .97
151P . . . . . . . . . . . . . . . . . . . . . .97
152 . . . . . . . . . . . . . . . . . . . . . . .97
17 SA . . . . . . . . . . . . . . . . . . . .100
1707 . . . . . . . . . . . . . . . . . . . . .145
1707DC . . . . . . . . . . . . . . . . . .145
1708 . . . . . . . . . . . . . . . . . . . . .145
1708DC . . . . . . . . . . . . . . . . . .145
1709 . . . . . . . . . . . . . . . . . . . . .145
191
192
193
194
195
196
1050
1051
1052
1053
1054
1055
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
152P . . . . . . . . . . . . . . . . . . . . . .97
153 . . . . . . . . . . . . . . . . . . . . . . .97
153P . . . . . . . . . . . . . . . . . . . . . .97
154 . . . . . . . . . . . . . . . . . . . . . . .97
154P . . . . . . . . . . . . . . . . . . . . . .97
155 . . . . . . . . . . . . . . . . . . . . . . .97
1709DC . . . . . . . . . . . . . . . . . .145
170C . . . . . . . . . . . . . . . . . . . . . .97
1710 . . . . . . . . . . . . . . . . . . . . .145
1710DC . . . . . . . . . . . . . . . . . . .145
1711 . . . . . . . . . . . . . . . . . . . . .145
1711DC . . . . . . . . . . . . . . . . . . .145
197 . . . . . . . . . . . . . . . . . . . . . .106
198 . . . . . . . . . . . . . . . . . . . . . .106
199 . . . . . . . . . . . . . . . . . . . . . .106
19DC . . . . . . . . . . . . . . . . . . . .100
19X . . . . . . . . . . . . . . . . . . . . . .100
1B . . . . . . . . . . . . . . . . . . . . . . .111
1056
1057
1058
1059
1060
1061
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . .106
155P . . . . . . . . . . . . . . . . . . . . . .97
15DC . . . . . . . . . . . . . . . . . . . .100
15X . . . . . . . . . . . . . . . . . . . . . .100
16 . . . . . . . . . . . . . . . . . . . . . . .100
16 SA . . . . . . . . . . . . . . . . . . . .100
160 . . . . . . . . . . . . . . . . . . . . . . .97
1712 . . . . . . . . . . . . . . . . . . . . .145
1712DC . . . . . . . . . . . . . . . . . .145
1713 . . . . . . . . . . . . . . . . . . . . .145
1713DC . . . . . . . . . . . . . . . . . .145
1714 . . . . . . . . . . . . . . . . . . . . .145
1714DC . . . . . . . . . . . . . . . . . .145
2 1/2 B . . . . . . . . . . . . . . . . . . .111
20 . . . . . . . . . . . . . . . . . . . . . . .100
20 SA . . . . . . . . . . . . . . . . . . . .100
200 . . . . . . . . . . . . . . . . . . . . . . .95
201 . . . . . . . . . . . . . . . . . . . . . . .95
202 . . . . . . . . . . . . . . . . . . . . . . .95
10N . . . . . . . . . . . . . . . . . . . . . .136
11 . . . . . . . . . . . . . . . . . . . . . . .100
11 SA . . . . . . . . . . . . . . . . . . . .100
11DC . . . . . . . . . . . . . . . . . . . . .100
11N . . . . . . . . . . . . . . . . . . . . . .136
11X . . . . . . . . . . . . . . . . . . . . . .100
160I . . . . . . . . . . . . . . . . . . . . . .97
160P . . . . . . . . . . . . . . . . . . . . . .97
161 . . . . . . . . . . . . . . . . . . . . . . .97
161I . . . . . . . . . . . . . . . . . . . . . .97
161P . . . . . . . . . . . . . . . . . . . . . .97
162 . . . . . . . . . . . . . . . . . . . . . . .97
1715 . . . . . . . . . . . . . . . . . . . . .145
1715DC . . . . . . . . . . . . . . . . . .145
171C . . . . . . . . . . . . . . . . . . . . . .97
1721 . . . . . . . . . . . . . . . . . . . . .145
1721DC . . . . . . . . . . . . . . . . . .145
1722 . . . . . . . . . . . . . . . . . . . . .145
203
204
205
206
207
208
12 . . . . . . . . . . . . . . . . . . . . . . .100
12 SA . . . . . . . . . . . . . . . . . . . .100
12DC . . . . . . . . . . . . . . . . . . . .100
12N . . . . . . . . . . . . . . . . . . . . . .136
12X . . . . . . . . . . . . . . . . . . . . . .100
13 . . . . . . . . . . . . . . . . . . . . . . .100
163 . . . . . . . . . . . . . . . . . . . . . . .97
164 . . . . . . . . . . . . . . . . . . . . . . .97
165 . . . . . . . . . . . . . . . . . . . . . . .97
1650 . . . . . . . . . . . . . . . . . . . . . .89
1650DC . . . . . . . . . . . . . . . . . . .92
1650RT . . . . . . . . . . . . . . . . . . . .89
1722DC . . . . . . . . . . . . . . . . . .145
1723 . . . . . . . . . . . . . . . . .141, 147
1724DC . . . . . . . . . . . . . . . . . .147
1735 . . . . . . . . . . . . . . . . .141, 147
1736 . . . . . . . . . . . . . . . . . . . . .147
1736DC . . . . . . . . . . . . . . . . . .147
209 . . . . . . . . . . . . . . . . . . .95, 111
20DC . . . . . . . . . . . . . . . . . . . .100
20X . . . . . . . . . . . . . . . . . . . . . .100
22 . . . . . . . . . . . . . . . . . . . . . . .100
23 . . . . . . . . . . . . . . . . . . . . . . .100
2400 . . . . . . . . . . . . . . . . . . . . . .92
13 SA . . . . . . . . . . . . . . . . . . . .100
13DC . . . . . . . . . . . . . . . . . . . .100
13N . . . . . . . . . . . . . . . . . . . . . .136
13X . . . . . . . . . . . . . . . . . . . . . .100
14 . . . . . . . . . . . . . . . . . . . . . . .100
14 SA . . . . . . . . . . . . . . . . . . . .100
1651 . . . . . . . . . . . . . . . . . . . . . .89
1651DC . . . . . . . . . . . . . . . . . . .92
1651RT . . . . . . . . . . . . . . . . . . . .89
1652 . . . . . . . . . . . . . . . . . . . . . .89
1652DC . . . . . . . . . . . . . . . . . . .92
1652RT . . . . . . . . . . . . . . . . . . . .89
1737 . . . . . . . . . . . . . . . . .141, 147
1738 . . . . . . . . . . . . . . . . . . . . .147
1738DC . . . . . . . . . . . . . . . . . .147
1739 . . . . . . . . . . . . . . . . . . . . .147
1739DC . . . . . . . . . . . . . . . . . .147
1740 . . . . . . . . . . . . . . . . . . . . .147
2401 . . . . . . . . . . . . . . . . . . . . . .92
2402 . . . . . . . . . . . . . . . . . . . . . .92
2420 . . . . . . . . . . . . . . . . . .92, 100
2421 . . . . . . . . . . . . . . . . . .92, 100
250 . . . . . . . . . . . . . . . . . .116, 117
251 . . . . . . . . . . . . . . . . . . . . . .113
1450 . . . . . . . . . . . . . . . . . . . . . .91
1450DC . . . . . . . . . . . . . . . . . . .92
1451 . . . . . . . . . . . . . . . . . . . . . .91
1451DC . . . . . . . . . . . . . . . . . . .92
1452 . . . . . . . . . . . . . . . . . . . . . .91
1452DC . . . . . . . . . . . . . . . . . . .92
1653 . . . . . . . . . . . . . . . . . . . . . .89
1653DC . . . . . . . . . . . . . . . . . . .92
1653RT . . . . . . . . . . . . . . . . . . . .89
1654 . . . . . . . . . . . . . . . . . . . . . .89
1654DC . . . . . . . . . . . . . . . . . . .92
1654RT . . . . . . . . . . . . . . . . . . . .89
1740DC . . . . . . . . . . . . . . . . . . .147
1741 . . . . . . . . . . . . . . . . . . . . .147
1741DC . . . . . . . . . . . . . . . . . . .147
1742 . . . . . . . . . . . . . . . . . . . . .147
1742DC . . . . . . . . . . . . . . . . . . .147
1744 . . . . . . . . . . . . . . . . . . . . .147
252
253
254
255
260
261
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
. . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . .95, 111
. . . . . . . . . . . . . . . . . . .95, 111
. . . . . . . . . . . . . . . . . . .95, 111
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
171
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
262 . . . . . . . . . . . . . . . . . . . . . .113
263 . . . . . . . . . . . . . . . . . . . . . .113
2631 . . . . . . . . . . . . . . . . .149, 151
2632 . . . . . . . . . . . . . . . . .149, 151
2633 . . . . . . . . . . . . . . . . .149, 151
2670 . . . . . . . . . . . . . . . . .149, 151
353
354
355
356
360
361
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
463 . . . . . . . . . . . . . . . . . . . . . . .91
463DC . . . . . . . . . . . . . . . . . . . .92
464 . . . . . . . . . . . . . . . . . . . . . . .91
464DC . . . . . . . . . . . . . . . . . . . .92
465 . . . . . . . . . . . . . . . . . . . . . . .91
465DC . . . . . . . . . . . . . . . . . . . .92
53D . . . . . . . . . . . . . . . . . . . . . .108
54 . . . . . . . . . . . . . . . . . . . . . . .106
54D . . . . . . . . . . . . . . . . . . . . . .108
55 . . . . . . . . . . . . . . . . . . . . . . .106
55D . . . . . . . . . . . . . . . . . . . . . .108
56 . . . . . . . . . . . . . . . . . . . . . . .106
2671 . . . . . . . . . . . . . . . . .149, 151
268 . . . . . . . . . . . . . . . . . . . . . .113
269 . . . . . . . . . . . . . . . . . . . . . .113
2699 . . . . . . . . . . . . .141, 145, 149
270 S . . . . . . . . . . . . . . . . . . . .113
275 . . . . . . . . . . . . . . . . . . . . . .113
362
363
364
365
366
367
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
466 . . . . . . . . . . . . . . . . . . . .91, 97
466DC . . . . . . . . . . . . . . . . . . . .92
467 . . . . . . . . . . . . . . . . . . . .91, 97
467DC . . . . . . . . . . . . . . . . . . . .92
468 . . . . . . . . . . . . . . . . . . . .91, 97
468DC . . . . . . . . . . . . . . . . . . . .92
566 . . . . . . . . . . . . . . . . . . . . . .141
567 . . . . . . . . . . . . . . . . . . . . . .141
56D . . . . . . . . . . . . . . . . . . . . . .108
57 . . . . . . . . . . . . . . . . . . . . . . .106
57D . . . . . . . . . . . . . . . . . . . . . .108
58 . . . . . . . . . . . . . . . . . . . . . . .106
276
281
282
283
285
288
368
369
370
371
372
373
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
S . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
469 . . . . . . . . . . . . . . . . . . . .91, 97
469DC . . . . . . . . . . . . . . . . . . . .92
496 10 . . . . . . . . . . . . . . . .95, 109
496 11 . . . . . . . . . . . . . . . . .95, 109
496 12 . . . . . . . . . . . . . . . .95, 109
496 2 . . . . . . . . . . . . . . . . . . . .109
58D . . . . . . . . . . . . . . . . . . . . . .108
59 . . . . . . . . . . . . . . . . . . . . . . .106
59D . . . . . . . . . . . . . . . . . . . . . .108
6 B . . . . . . . . . . . . . . . . . . . . . . .111
60 . . . . . . . . . . . . . . . . . . . . . . .106
61 . . . . . . . . . . . . . . . . . . . . . . .106
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
. . . . . . . . . . . . . . . . . . . . . .113
289 . . . . . . . . . . . . . . . . . . . . . .113
290M . . . . . . . . . . . . . . . . . . . . .113
291 . . . . . . . . . . . . . . . . . . . . . .113
292 . . . . . . . . . . . . . . . . . . . . . .113
293 . . . . . . . . . . . . . . . . . . . . . .113
294 . . . . . . . . . . . . . . . . . . . . . .113
374 . . . . . . . . . . . . . . . . . . . . . .109
375 . . . . . . . . . . . . . . . . . . . . . .109
376 . . . . . . . . . . . . . . . . . . . . . .109
377 . . . . . . . . . . . . . . . . . . . . . .109
378 . . . . . . . . . . . . . . . . . . . . . .109
4 B . . . . . . . . . . . . . . . . . . . . . . .111
496
496
496
496
496
496
3
4
5
6
7
8
. . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . .109
631 . . . . . . . . . . . . . . . . . .149, 151
632 . . . . . . . . . . . . . . . . . .149, 151
65 . . . . . . . . . . . . . . . . . . . . . . .100
650 . . . . . . . . . . . . . . . . . .116, 117
650DC . . . . . . . . . . . . . . . . . . . .92
650RT . . . . . . . . . . . . . . . . . . . . .89
295 . . . . . . . . . . . . . . . . . . . . . .113
296 . . . . . . . . . . . . . . . . . . . . . .113
297 . . . . . . . . . . . . . . . . . . . . . .113
298 . . . . . . . . . . . . . . . . . . . . . .113
299 . . . . . . . . . . . . . . . . . . . . . .113
2B . . . . . . . . . . . . . . . . . . . . . . .111
410 . . . . . . . . . . . . . . . . . . . . . .111
411 . . . . . . . . . . . . . . . . . . . . . . .111
412 . . . . . . . . . . . . . . . . . . . . . .111
413 . . . . . . . . . . . . . . . . . . . . . .111
414 . . . . . . . . . . . . . . . . . . . . . .111
415 . . . . . . . . . . . . . . . . . . . . . .111
496
497
497
497
497
497
9
1
2
3
4
5
. . . . . . . . . . . . . . . . .95, 109
. . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . . . .95
. . . . . . . . . . . . . . . . . . . . .95
650S . . . . . . . . . . . . . . . . . . . . . .89
651DC . . . . . . . . . . . . . . . . . . . .92
651RT . . . . . . . . . . . . . . . . . . . . .89
651S . . . . . . . . . . . . . . . . . . . . . .89
652 . . . . . . . . . . . . . . . . . . . . . . .89
652DC . . . . . . . . . . . . . . . . . . . .92
3 B . . . . . . . . . . . . . . . . . . . . . . .111
300 . . . . . . . . . . . . . . . . . . . . . .108
3000 . . . . . . . . . . . . . . . . . . . . .151
300DC . . . . . . . . . . . . . . . . . . .108
301 . . . . . . . . . . . . . . . . . . . . . .108
301DC . . . . . . . . . . . . . . . . . . . .108
420 . . . . . . . . . . . . . . . . . . .92, 100
421 . . . . . . . . . . . . . . . . . . .92, 100
422 . . . . . . . . . . . . . . . . . . .92, 100
450 . . . . . . . . . . . . . . . . . .116, 117
450DC . . . . . . . . . . . . . . . . . . . .92
450S . . . . . . . . . . . . . . . . . . . . . .91
497 6 . . . . . . . . . . . . . . . . . . . . .95
5 B . . . . . . . . . . . . . . . . . . . . . . .111
50 . . . . . . . . . . . . . . . . . . . . . . .106
5050 . . . . . . . . . . . . . . . . . . . . .149
50D . . . . . . . . . . . . . . . . . . . . . .108
51 . . . . . . . . . . . . . . . . . . . . . . .106
652RT . . . . . . . . . . . . . . . . . . . . .89
653 . . . . . . . . . . . . . . . . . . . . . . .89
653DC . . . . . . . . . . . . . . . . . . . .92
653RT . . . . . . . . . . . . . . . . . . . . .89
654 . . . . . . . . . . . . . . . . . . . . . . .89
654DC . . . . . . . . . . . . . . . . . . . .92
302 . . . . . . . . . . . . . . . . . . . . . .108
302DC . . . . . . . . . . . . . . . . . . .108
303 . . . . . . . . . . . . . . . . . . . . . .108
303DC . . . . . . . . . . . . . . . . . . .108
304DC . . . . . . . . . . . . . . . . . . .108
305DC . . . . . . . . . . . . . . . . . . .108
451 . . . . . . . . . . . . . . . . . . . . . . .91
451DC . . . . . . . . . . . . . . . . . . . .92
452 . . . . . . . . . . . . . . . . . . . . . . .91
452DC . . . . . . . . . . . . . . . . . . . .92
453 . . . . . . . . . . . . . . . . . . . . . . .91
453DC . . . . . . . . . . . . . . . . . . . .92
510
511
512
513
514
515
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
654RT . . . . . . . . . . . . . . . . . . . . .89
655 . . . . . . . . . . . . . . . . . . . . . . .89
655DC . . . . . . . . . . . . . . . . . . . .92
655RT . . . . . . . . . . . . . . . . . . . . .89
656 . . . . . . . . . . . . . . . . . . . . . . .89
656DC . . . . . . . . . . . . . . . . . . . .92
335
336
337
338
339
340
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
454 . . . . . . . . . . . . . . . . . . . . . . .91
454DC . . . . . . . . . . . . . . . . . . . .92
455 . . . . . . . . . . . . . . . . . . . . . . .91
455DC . . . . . . . . . . . . . . . . . . . .92
456 . . . . . . . . . . . . . . . . . . . .91, 97
456DC . . . . . . . . . . . . . . . . . . . .92
516 . . . . . . . . . . . . . . . . . . .95, 109
517 . . . . . . . . . . . . . . . . . . .95, 109
518 . . . . . . . . . . . . . . . . . . .95, 109
519 . . . . . . . . . . . . . . . . . . .95, 109
51D . . . . . . . . . . . . . . . . . . . . . .108
52 . . . . . . . . . . . . . . . . . . . . . . .106
656RT . . . . . . . . . . . . . . . . . . . . .89
657 . . . . . . . . . . . . . . . . . . . . . . .89
657DC . . . . . . . . . . . . . . . . . . . .92
657RT . . . . . . . . . . . . . . . . . . . . .89
658 . . . . . . . . . . . . . . . . . . . . . . .89
658DC . . . . . . . . . . . . . . . . . . . .92
342
343
344
345
346
347
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
. . . . . . . . . . . . . . . . . . . . . .109
457 . . . . . . . . . . . . . . . . . . . .91, 97
457DC . . . . . . . . . . . . . . . . . . . .92
458 . . . . . . . . . . . . . . . . . . . .91, 97
458DC . . . . . . . . . . . . . . . . . . . .92
459 . . . . . . . . . . . . . . . . . . . .91, 97
459DC . . . . . . . . . . . . . . . . . . . .92
520 . . . . . . . . . . . . . . . . . . . . . .109
521 . . . . . . . . . . . . . . . . . . . . . .109
528 . . . . . . . . . . . . . . . . . . . . . .111
529 . . . . . . . . . . . . . . . . . . . . . .111
529 S . . . . . . . . . . . . . . . . . . . . .111
52D . . . . . . . . . . . . . . . . . . . . . .108
658RT . . . . . . . . . . . . . . . . . . . . .89
659 . . . . . . . . . . . . . . . . . . . . . . .89
659DC . . . . . . . . . . . . . . . . . . . .92
659RT . . . . . . . . . . . . . . . . . . . . .89
66 . . . . . . . . . . . . . . . . . . . . . . .100
660DC . . . . . . . . . . . . . . . . . . . .92
348 . . . . . . . . . . . . . . . . . . . . . .109
349 . . . . . . . . . . . . . . . . . . . . . .109
350 . . . . . . . . . . . . . . . . . .116, 117
350S . . . . . . . . . . . . . . . . . . . . .109
351 . . . . . . . . . . . . . . . . . . . . . .109
352 . . . . . . . . . . . . . . . . . . . . . .109
460 . . . . . . . . . . . . . . . . . . . . . . .91
460DC . . . . . . . . . . . . . . . . . . . .92
461 . . . . . . . . . . . . . . . . . . . . . . .91
461DC . . . . . . . . . . . . . . . . . . . .92
462 . . . . . . . . . . . . . . . . . . . . . . .91
462DC . . . . . . . . . . . . . . . . . . . .92
53 . . . . . . . . . . . . . . . . . . . . . . .106
530 . . . . . . . . . . . . . . . . . . . . . .111
531 . . . . . . . . . . . . . . . . . . . . . .111
532 . . . . . . . . . . . . . . . . . . . . . .111
533 . . . . . . . . . . . . . . . . . . . . . .111
534 . . . . . . . . . . . . . . . . . . . . . .111
660RT . . . . . . . . . . . . . . . . . . . . .89
660S . . . . . . . . . . . . . . . . . . . . . .89
661DC . . . . . . . . . . . . . . . . . . . .92
661RT . . . . . . . . . . . . . . . . . . . . .89
661S . . . . . . . . . . . . . . . . . . . . . .89
662 . . . . . . . . . . . . . . . . . . . . . . .89
172
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
662DC . . . . . . . . . . . . . . . . . . . .92
662RT . . . . . . . . . . . . . . . . . . . . .89
663 . . . . . . . . . . . . . . . . . . . . . . .89
663DC . . . . . . . . . . . . . . . . . . . .92
663RT . . . . . . . . . . . . . . . . . . . . .89
664 . . . . . . . . . . . . . . . . . . . . . . .89
737 . . . . . . . . . . . . . . . . . .141, 147
738 . . . . . . . . . . . . . . . . . . . . . .147
738DC . . . . . . . . . . . . . . . . . . .147
739 . . . . . . . . . . . . . . . . . . . . . .147
739DC . . . . . . . . . . . . . . . . . . .147
740 . . . . . . . . . . . . . . . . . . . . . .147
875EB DC . . . . . . . . . . . . . . . . .95
875EE DC . . . . . . . . . . . . . . . . .95
875RB DC . . . . . . . . . . . . . . . .108
875RR DC . . . . . . . . . . . . . . . .108
9 B . . . . . . . . . . . . . . . . . . . . . . .111
90 . . . . . . . . . . . . . . . . . . . . . . .109
ASB 8 . . . . . . . . . . . . . . . .141, 149
BJ104 . . . . . . . . . . . . . . . .168, 169
BJ108 . . . . . . . . . . . . . . . . . . . .168
BJ14 . . . . . . . . . . . . . . . . .168, 169
BJ18 . . . . . . . . . . . . . . . . . . . . .168
BJ24 . . . . . . . . . . . . . . . . .168, 169
664DC . . . . . . . . . . . . . . . . . . . .92
664RT . . . . . . . . . . . . . . . . . . . . .89
665 . . . . . . . . . . . . . . . . . . . . . . .89
665DC . . . . . . . . . . . . . . . . . . . .92
665RT . . . . . . . . . . . . . . . . . . . . .89
666 . . . . . . . . . . . . . . . . . . . . . . .89
740DC . . . . . . . . . . . . . . . . . . . .147
741 . . . . . . . . . . . . . . . . . . . . . .147
741DC . . . . . . . . . . . . . . . . . . . .147
742 . . . . . . . . . . . . . . . . . . . . . .147
742DC . . . . . . . . . . . . . . . . . . . .147
744 . . . . . . . . . . . . . . . . . . . . . .147
91 . . . . . . . . . . . . . . . . . . . . . . .109
92 . . . . . . . . . . . . . . . . . . . . . . .109
93 . . . . . . . . . . . . . . . . . . . . . . .109
931 . . . . . . . . . . . . . . . . . . . . . .104
932 . . . . . . . . . . . . . . . . . . . . . .104
933 . . . . . . . . . . . . . . . . . . . . . .104
BJ28
BJ34
BJ38
BJ44
BJ48
BJ54
. . . . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . .168, 169
. . . . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . .168, 169
. . . . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . .168, 169
666DC . . . . . . . . . . . . . . . . . . . .92
666RT . . . . . . . . . . . . . . . . . . . . .89
667 . . . . . . . . . . . . . . . . . . . . . . .89
667DC . . . . . . . . . . . . . . . . . . . .92
667RT . . . . . . . . . . . . . . . . . . . . .89
668 . . . . . . . . . . . . . . . . . . . . . . .89
744DC . . . . . . . . . . . . . . . . . . . .147
745 . . . . . . . . . . . . . . . . . . . . . .147
745DC . . . . . . . . . . . . . . . . . . . .147
746 . . . . . . . . . . . . . . . . . . . . . .147
746DC . . . . . . . . . . . . . . . . . . . .147
747 . . . . . . . . . . . . . . . . . . . . . .147
934
935
936
937
938
939
BJ58
BJ64
BJ68
BJ74
BJ78
BJ84
. . . . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . .168, 169
. . . . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . .168, 169
. . . . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . .168, 169
668DC . . . . . . . . . . . . . . . . . . . .92
668RT . . . . . . . . . . . . . . . . . . . . .89
669 . . . . . . . . . . . . . . . . . . . . . . .89
669DC . . . . . . . . . . . . . . . . . . . .92
669RT . . . . . . . . . . . . . . . . . . . . .89
67 . . . . . . . . . . . . . . . . . . . . . . .100
747DC . . . . . . . . . . . . . . . . . . . .147
759DC . . . . . . . . . . . . . . . . . . .149
770DC . . . . . . . . . . . . . . . . . . .147
771DC . . . . . . . . . . . . . . . . . . .147
772DC . . . . . . . . . . . . . . . . . . .147
773DC . . . . . . . . . . . . . . . . . . .147
94 . . . . . . . . . . . . . . . . . . . . . . .109
940 . . . . . . . . . . . . . . . . . . . . . .104
941 . . . . . . . . . . . . . . . . . . . . . .104
942 . . . . . . . . . . . . . . . . . . . . . .104
95 . . . . . . . . . . . . . . . . . . . . . . .109
950D . . . . . . . . . . . . . . . . .116, 117
BJ88 . . . . . . . . . . . . . . . . . . . . .168
BJ94 . . . . . . . . . . . . . . . . .168, 169
BJ98 . . . . . . . . . . . . . . . . . . . . .168
BSC50DC . . . . . . . . . . . . . . . . . .95
BSC75DC . . . . . . . . . . . . . . . . . .95
BSS50 . . . . . . . . . . . . . . . . . . . .95
68 . . . . . . . . . . . . . . . . . . . . . . .100
690S . . . . . . . . . . . . . . . . . . .91, 99
691 . . . . . . . . . . . . . . . . . . . .91, 99
692 . . . . . . . . . . . . . . . . . . . .91, 99
699 . . . . . . . . . . . . . . . . . .141, 145
7 B . . . . . . . . . . . . . . . . . . . . . . .111
774DC . . . . . . . . . . . . . . . . . . . .147
775DC . . . . . . . . . . . . . . . . . . .147
776DC . . . . . . . . . . . . . . . . . . .147
780DC . . . . . . . . . . . . . . . .95, 149
791DC . . . . . . . . . . . . . . . . . . .147
792DC . . . . . . . . . . . . . . . . . . .147
96 . . . . . . . . . . . . . . . . . . . . . . .109
97 . . . . . . . . . . . . . . . . . . . . . . .109
98 . . . . . . . . . . . . . . . . . . . . . . .109
99 . . . . . . . . . . . . . . . . . . . . . . .109
ACB100 . . . . . . . . . . . . . .139, 143
ACB10090 . . . . . . . . . . . .139, 143
BSS75 . . . . . . . . . . . . . . . . . . . .95
C100M . . . . . . . . . . . . . . . . . . .121
C105 . . . . . . . . . . . . . . . . . . . . .117
C125M . . . . . . . . . . . . . . . . . . .121
C15 . . . . . . . . . . . . . . . . . . . . . .117
C15 MT . . . . . . . . . . . . . . . . . . .116
700 . . . . . . . . . . . . . . . . . .141, 145
702V . . . . . . . . . . . . . . . . .141, 145
707 . . . . . . . . . . . . . . . . . . . . . .145
707DC . . . . . . . . . . . . . . . . . . .145
708 . . . . . . . . . . . . . . . . . . . . . .145
708DC . . . . . . . . . . . . . . . . . . .145
793DC . . . . . . . . . . . . . . . . . . .147
794DC . . . . . . . . . . . . . . . . . . .147
795DC . . . . . . . . . . . . . . . . . . .147
796DC . . . . . . . . . . . . . . . . . . .147
8 B . . . . . . . . . . . . . . . . . . . . . . .111
810 . . . . . . . . . . . . . . . . . . . . . .108
ACB125
ACB150
ACB200
ACB250
ACB300
ACB350
. . . . . . . . . . . . . .139,
. . . . . . . . . . . . . .139,
. . . . . . . . . . . . . .139,
. . . . . . . . . . . . . .139,
. . . . . . . . . . . . . .139,
. . . . . . . . . . . . . .139,
143
143
143
143
143
143
C150M . . . . . . . . . . . . . . . . . . .121
C200M . . . . . . . . . . . . . . . . . . .121
C25 . . . . . . . . . . . . . . . . . . . . . .117
C25 MT . . . . . . . . . . . . . . . . . . .116
C250M . . . . . . . . . . . . . . . . . . .121
C300M . . . . . . . . . . . . . . . . . . .121
709 . . . . . . . . . . . . . . . . . . . . . .145
709DC . . . . . . . . . . . . . . . . . . .145
710 . . . . . . . . . . . . . . . . . . . . . .145
710DC . . . . . . . . . . . . . . . . . . .145
711 . . . . . . . . . . . . . . . . . . . . . .145
711DC . . . . . . . . . . . . . . . . . . . .145
8100EB DC . . . . . . . . . . . . . . . .95
8100EE DC . . . . . . . . . . . . . . . .95
8100RB DC . . . . . . . . . . . . . . .108
8100RR DC . . . . . . . . . . . . . . .108
811 . . . . . . . . . . . . . . . . . . . . . .108
812 . . . . . . . . . . . . . . . . . . . . . .108
ACB38 . . . . . . . . . . . . . . .139,
ACB3845 . . . . . . . . . . . . .139,
ACB3890 . . . . . . . . . . . . .139,
ACB400 . . . . . . . . . . . . . .139,
ACB50 . . . . . . . . . . . . . . .139,
ACB5045 . . . . . . . . . . . . .139,
143
143
143
143
143
143
C35 . . . . . . . . . . . . . . . . . . . . . .117
C35 MT . . . . . . . . . . . . . . . . . . .116
C350M . . . . . . . . . . . . . . . . . . .121
C400M . . . . . . . . . . . . . . . . . . .121
C45 . . . . . . . . . . . . . . . . . . . . . .117
C45 MT . . . . . . . . . . . . . . . . . . .116
712 . . . . . . . . . . . . . . . . . . . . . .145
712DC . . . . . . . . . . . . . . . . . . .145
713 . . . . . . . . . . . . . . . . . . . . . .145
713DC . . . . . . . . . . . . . . . . . . .145
714 . . . . . . . . . . . . . . . . . . . . . .145
714DC . . . . . . . . . . . . . . . . . . .145
8125EB DC . . . . . . . . . . . . . . . .95
8125EE DC . . . . . . . . . . . . . . . .95
8125RB DC . . . . . . . . . . . . . . .108
8125RR DC . . . . . . . . . . . . . . .108
813 . . . . . . . . . . . . . . . . . . . . . .108
814 . . . . . . . . . . . . . . . . . . . . . .108
ACB5090 . . . . . . . . . . . . .139,
ACB75 . . . . . . . . . . . . . . .139,
ACB7545 . . . . . . . . . . . . .139,
ACB7590 . . . . . . . . . . . . .139,
ACC38 . . . . . . . . . . . . . . .140,
ACC50 . . . . . . . . . . . . . . .140,
143
143
143
143
143
143
C50M . . . . . . . . . . . . . . . . . . . .121
C55 . . . . . . . . . . . . . . . . . . . . . .117
C55 MT . . . . . . . . . . . . . . . . . . .116
C65 . . . . . . . . . . . . . . . . . . . . . .117
C65 MT . . . . . . . . . . . . . . . . . . .116
C75 . . . . . . . . . . . . . . . . . . . . . .117
715 . . . . . . . . . . . . . . . . . . . . . .145
715DC . . . . . . . . . . . . . . . . . . .145
721 . . . . . . . . . . . . . . . . . . . . . .145
721DC . . . . . . . . . . . . . . . . . . .145
722 . . . . . . . . . . . . . . . . . . . . . .145
722DC . . . . . . . . . . . . . . . . . . .145
815
820
821
822
823
824
ACC75 . . . . . . . . . . . . . . .140,
ACCSS38 . . . . . . . . . . . . .140,
ACCSS50 . . . . . . . . . . . . .140,
ACCSS75 . . . . . . . . . . . . .140,
ASB 0 . . . . . . . . . . . . . . . .141,
ASB 1 . . . . . . . . . . . . . . . .141,
143
143
143
143
149
149
C75M . . . . . . . . . . . . . . . . . . . .121
C85 . . . . . . . . . . . . . . . . . . . . . .117
C95 . . . . . . . . . . . . . . . . . . . . . .117
CB1 . . . . . . . . . . . . . . . . . .95, 109
CB10 . . . . . . . . . . . . . . . . . .95, 109
CB11 . . . . . . . . . . . . . . . . . .95, 109
723 . . . . . . . . . . . . . . . . . .141, 147
724 . . . . . . . . . . . . . . . . . . . . . .147
724DC . . . . . . . . . . . . . . . . . . .147
735 . . . . . . . . . . . . . . . . . .141, 147
736 . . . . . . . . . . . . . . . . . . . . . .147
736DC . . . . . . . . . . . . . . . . . . .147
825 . . . . . . . . . . . . . . . . . . . . . .108
850D . . . . . . . . . . . . . . . . .116, 117
850EB DC . . . . . . . . . . . . . . . . .95
850EE DC . . . . . . . . . . . . . . . . .95
850RB DC . . . . . . . . . . . . . . . .108
850RR DC . . . . . . . . . . . . . . . .108
ASB
ASB
ASB
ASB
ASB
ASB
149
149
149
149
149
149
CB12 . . . . . . . . . . . . . . . . . .95,
CB2 . . . . . . . . . . . . . . . . . .95,
CB3 . . . . . . . . . . . . . . . . . .95,
CB4 . . . . . . . . . . . . . . . . . .95,
CB5 . . . . . . . . . . . . . . . . . .95,
CB6 . . . . . . . . . . . . . . . . . .95,
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . . . . . .108
US: 1-866-764-5454
CAN: 1-800-265-0502
. . . . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . . . .104
2
3
4
5
6
7
. . . . . . . . . . . . . . . .141,
. . . . . . . . . . . . . . . .141,
. . . . . . . . . . . . . . . .141,
. . . . . . . . . . . . . . . .141,
. . . . . . . . . . . . . . . .141,
. . . . . . . . . . . . . . . .141,
Copyright© 2007 Cooper Crouse-Hinds
109
109
109
109
109
109
173
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
CB7 . . . . . . . . . . . . . . . . . .95, 109
CB8 . . . . . . . . . . . . . . . . . .95, 109
CB9 . . . . . . . . . . . . . . . . . .95, 109
CG100 1050 . . . . . . . . . . . . . . .136
CG100 560 . . . . . . . . . . . . . . . .136
CG100 650 . . . . . . . . . . . . . . . .136
CG7590
CG7590
CG7590
CG7590
CG7590
CG7590
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
EHSS9 . . . . . . . . . . . . . . . . . . .151
EHT1 . . . . . . . . . . . . . . . . . . . .151
EHT10 . . . . . . . . . . . . . . . . . . .151
EHT2 . . . . . . . . . . . . . . . . . . . .151
EHT3 . . . . . . . . . . . . . . . . . . . .151
EHT4 . . . . . . . . . . . . . . . . . . . .151
GLL10C . . . . . . . . . . . . . . . . . .102
GLL11 . . . . . . . . . . . . . . . . .85, 102
GLL11 250 . . . . . . . . . . . . . . . .102
GLL11 250C . . . . . . . . . . . . . . .102
GLL11C . . . . . . . . . . . . . . . . . .102
GLL12 . . . . . . . . . . . . . . . . .85, 102
CG100 750 . . . . . . . . . . . . . . . .136
CG100 850 . . . . . . . . . . . . . . . .136
CG100 950 . . . . . . . . . . . . . . . .136
CG10045 1050 . . . . . . . . . . . . .136
CG10045 560 . . . . . . . . . . . . . .136
CG10045 650 . . . . . . . . . . . . . .136
CG7590 850 . . . . . . . . . . . . . . .136
CPR1 . . . . . . . . . . . . . . . . . . . . .97
CPR10 . . . . . . . . . . . . . . . . . . . .97
CPR11 . . . . . . . . . . . . . . . . . . . .97
CPR12 . . . . . . . . . . . . . . . . . . . .97
CPR13 . . . . . . . . . . . . . . . . . . . .97
EHT5 . . . . . . . . . . . . . . . . . . . .151
EHT6 . . . . . . . . . . . . . . . . . . . .151
EHT7 . . . . . . . . . . . . . . . . . . . .151
EHT8 . . . . . . . . . . . . . . . . . . . .151
EHT9 . . . . . . . . . . . . . . . . . . . .151
ETC100HD . . . . . . . . . . . . . . . .111
GLL12 250 . . . . . . . . . . . . . . . .102
GLL12 250C . . . . . . . . . . . . . . .102
GLL12C . . . . . . . . . . . . . . . . . .102
GLL1C . . . . . . . . . . . . . . . . . . .102
GLL2 . . . . . . . . . . . . . . . . . .85, 102
GLL2 DC . . . . . . . . . . . . . . . . .102
CG10045
CG10045
CG10045
CG10090
CG10090
CG10090
CPR14
CPR15
CPR16
CPR17
CPR18
CPR19
. . . . . . . . . . . . . . . . . . . .97
. . . . . . . . . . . . . . . . . . . .97
. . . . . . . . . . . . . . . . . . . .97
. . . . . . . . . . . . . . . . . . . .97
. . . . . . . . . . . . . . . . . . . .97
. . . . . . . . . . . . . . . . . . . .97
ETC125HD . . . . . . . . . . . . . . . .111
ETC150HD . . . . . . . . . . . . . . . .111
ETC200HD . . . . . . . . . . . . . . . .111
ETC250HD . . . . . . . . . . . . . . . .111
ETC300HD . . . . . . . . . . . . . . . .111
ETC50HD . . . . . . . . . . . . . . . . .111
GLL2C . . . . . . . . . . . . . . . . . . .102
GLL3 . . . . . . . . . . . . . . . . . .85, 102
GLL3 DC . . . . . . . . . . . . . . . . .102
GLL3C . . . . . . . . . . . . . . . . . . .102
GLL4 . . . . . . . . . . . . . . . . . .85, 102
GLL4 10 . . . . . . . . . . . . . . . . . .102
CG10090 750 . . . . . . . . . . . . . .136
CG10090 850 . . . . . . . . . . . . . .136
CG10090 950 . . . . . . . . . . . . . .136
CG125 1050 . . . . . . . . . . . . . . .136
CG125 1150 . . . . . . . . . . . . . . .136
CG125 1250 . . . . . . . . . . . . . . .136
CPR2 . . . . . . . . . . . . . . . . . . . . .97
CPR20 . . . . . . . . . . . . . . . . . . . .97
CPR21 . . . . . . . . . . . . . . . . . . . .97
CPR22 . . . . . . . . . . . . . . . . . . . .97
CPR23 . . . . . . . . . . . . . . . . . . . .97
CPR24 . . . . . . . . . . . . . . . . . . . .97
ETC75HD . . . . . . . . . . . . . . . . .111
FEA100 . . . . . . . . . . . . . . . . . . .131
FEA125 . . . . . . . . . . . . . . . . . . .131
FEA150 . . . . . . . . . . . . . . . . . . .131
FEA200 . . . . . . . . . . . . . . . . . .131
FEA250 . . . . . . . . . . . . . . . . . .131
GLL4 10C . . . . . . . . . . . . . . . . .102
GLL4 DC . . . . . . . . . . . . . . . . .102
GLL4C . . . . . . . . . . . . . . . . . . .102
GLL5 . . . . . . . . . . . . . . . . . .85, 102
GLL5 10 . . . . . . . . . . . . . . . . . .102
GLL5 10C . . . . . . . . . . . . . . . . .102
CG125
CG125
CG125
CG150
CG150
CG150
1375 . . . . . . . . . . . . . . .136
850 . . . . . . . . . . . . . . . .136
950 . . . . . . . . . . . . . . . .136
1050 . . . . . . . . . . . . . . .136
1150 . . . . . . . . . . . . . . .136
1250 . . . . . . . . . . . . . . .136
CPR25 . . . . . . . . . . . . . . . . . . . .97
CPR26 . . . . . . . . . . . . . . . . . . . .97
CPR27 . . . . . . . . . . . . . . . . . . . .97
CPR28 . . . . . . . . . . . . . . . . . . . .97
CPR29 . . . . . . . . . . . . . . . . . . . .97
CPR3 . . . . . . . . . . . . . . . . . . . . .97
FEA300 . . . . . . . . . . . . . . . . . .131
FEA350 . . . . . . . . . . . . . . . . . .131
FEA38 . . . . . . . . . . . . . . . . . . .131
FEA400 . . . . . . . . . . . . . . . . . .131
FEA50 . . . . . . . . . . . . . . . . . . .131
FEA75 . . . . . . . . . . . . . . . . . . .131
GLL5 DC . . . . . . . . . . . . . . . . .102
GLL5C . . . . . . . . . . . . . . . . . . .102
GLL6 . . . . . . . . . . . . . . . . . .85, 102
GLL6 10 . . . . . . . . . . . . . . . . . .102
GLL6 10C . . . . . . . . . . . . . . . . .102
GLL6 DC . . . . . . . . . . . . . . . . .102
CG150 1375 . . . . . . . . . . . . . . .136
CG50 250 . . . . . . . . . . . . . . . . .136
CG50 350 . . . . . . . . . . . . . . . . .136
CG50 450 . . . . . . . . . . . . . . . . .136
CG50 560 . . . . . . . . . . . . . . . . .136
CG50 650 . . . . . . . . . . . . . . . . .136
CPR30 . . . . . . . . . . . . . . . . . . . .97
CPR4 . . . . . . . . . . . . . . . . . . . . .97
CPR5 . . . . . . . . . . . . . . . . . . . . .97
CPR6 . . . . . . . . . . . . . . . . . . . . .97
CPR7 . . . . . . . . . . . . . . . . . . . . .97
CPR8 . . . . . . . . . . . . . . . . . . . . .97
GASK015N
GASK025N
GASK035N
GASK045N
GASK065N
GASK085N
117
117
117
117
117
117
GLL6C . . . . . . . . . . . . . . . .85, 102
GLL7 . . . . . . . . . . . . . . . . . .85, 102
GLL7 250 . . . . . . . . . . . . . . . . .102
GLL7 250C . . . . . . . . . . . . .85, 102
GLL7 30 . . . . . . . . . . . . . . . . . .102
GLL7 30C . . . . . . . . . . . . . . . . .102
CG5045
CG5045
CG5045
CG5045
CG5045
CG5090
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
CPR9 . . . . . . . . . . . . . . . . . . . . .97
EHC1 . . . . . . . . . . . . . . . . . . . .151
EHC10 . . . . . . . . . . . . . . . . . . .151
EHC2 . . . . . . . . . . . . . . . . . . . .151
EHC3 . . . . . . . . . . . . . . . . . . . .151
EHC4 . . . . . . . . . . . . . . . . . . . .151
GASK095N . . . . . . . . . . . .116, 117
GK100N . . . . . . . . . . . . . . . . . .121
GK125N . . . . . . . . . . . . . . . . . .121
GK200N . . . . . . . . . . . . . . . . . .121
GK250N . . . . . . . . . . . . . . . . . .121
GK350N . . . . . . . . . . . . . . . . . .121
GLL7 DC . . . . . . . . . . . . . . . . .102
GLL7C . . . . . . . . . . . . . . . . . . .102
GLL8 . . . . . . . . . . . . . . . . . .85, 102
GLL8 250 . . . . . . . . . . . . . . . . .102
GLL8 250C . . . . . . . . . . . . . . . .102
GLL8 30 . . . . . . . . . . . . . . . . . .102
CG5090 350 . . . . . . . . . . . . . . .136
CG5090 450 . . . . . . . . . . . . . . .136
CG5090 560 . . . . . . . . . . . . . . .136
CG5090 650 . . . . . . . . . . . . . . .136
CG75 250 . . . . . . . . . . . . . . . . .136
CG75 350 . . . . . . . . . . . . . . . . .136
EHC5 . . . . . . . . . . . . . . . . . . . .151
EHC6 . . . . . . . . . . . . . . . . . . . .151
EHC7 . . . . . . . . . . . . . . . . . . . .151
EHC8 . . . . . . . . . . . . . . . . . . . .151
EHC9 . . . . . . . . . . . . . . . . . . . .151
EHMT1 . . . . . . . . . . . . . . . . . . .151
GK50N . . . . . . . . . . . . . . . . . . .121
GK75N . . . . . . . . . . . . . . . . . . .121
GL 11 . . . . . . . . . . . . . . . . . . . .100
GL 12 . . . . . . . . . . . . . . . . . . . .100
GL 13 . . . . . . . . . . . . . . . . . . . .100
GL 14 . . . . . . . . . . . . . . . . . . . .100
GLL8 30C . . . . . . . . . . . . . . . . .102
GLL8 DC . . . . . . . . . . . . . . . . .102
GLL8C . . . . . . . . . . . . . . . . . . .102
GLL9 . . . . . . . . . . . . . . . . . .85, 102
GLL9 250 . . . . . . . . . . . . . . . . .102
GLL9 250C . . . . . . . . . . . . . . . .102
CG75 450 . . . . . . . . . . . . . . . . .136
CG75 560 . . . . . . . . . . . . . . . . .136
CG75 650 . . . . . . . . . . . . . . . . .136
CG75 750 . . . . . . . . . . . . . . . . .136
CG75 850 . . . . . . . . . . . . . . . . .136
CG7545 250 . . . . . . . . . . . . . . .136
EHMT2 . . . . . . . . . . . . . . . . . . .151
EHMT3 . . . . . . . . . . . . . . . . . . .151
EHMT4 . . . . . . . . . . . . . . . . . . .151
EHSS1 . . . . . . . . . . . . . . . . . . .151
EHSS10 . . . . . . . . . . . . . . . . . .151
EHSS2 . . . . . . . . . . . . . . . . . . .151
GL
GL
GL
GL
GL
GL
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
GLL9 DC . . . . . . . . . . . . . . . . .102
GLL9C . . . . . . . . . . . . . . . . . . .102
GLS 7C . . . . . . . . . . . . . . . . . . .102
GLS1 . . . . . . . . . . . . . . . . . . . .102
GLS10 . . . . . . . . . . . . . . . . . . . .102
GLS10 250 . . . . . . . . . . . . . . . .102
CG7545
CG7545
CG7545
CG7545
CG7545
CG7545
EHSS3
EHSS4
EHSS5
EHSS6
EHSS7
EHSS8
GLL1 . . . . . . . . . . . . . . . . . .85, 102
GLL1 DC . . . . . . . . . . . . . . . . .102
GLL10 . . . . . . . . . . . . . . . . .85, 102
GLL10 250 . . . . . . . . . . . . . . . .102
GLL10 250C . . . . . . . . . . . . . . .102
GLL10 DC . . . . . . . . . . . . . . . . .102
GLS10 250C . . . . . . . . . . . . . . .102
GLS10C . . . . . . . . . . . . . . . . . .102
GLS11 . . . . . . . . . . . . . . . . . . . .102
GLS11 250 . . . . . . . . . . . . . . . .102
GLS11 250C . . . . . . . . . . . . . . .102
GLS11C . . . . . . . . . . . . . . . . . .102
174
750 . . . . . . . . . . . . . .136
850 . . . . . . . . . . . . . .136
950 . . . . . . . . . . . . . .136
1050 . . . . . . . . . . . . .136
560 . . . . . . . . . . . . . .136
650 . . . . . . . . . . . . . .136
250
350
450
560
650
250
350
450
560
650
750
850
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
. . . . . . . . . . . . . . .136
250
350
450
560
650
750
. . . . . . . . . . . . . . . . . . .151
. . . . . . . . . . . . . . . . . . .151
. . . . . . . . . . . . . . . . . . .151
. . . . . . . . . . . . . . . . . . .151
. . . . . . . . . . . . . . . . . . .151
. . . . . . . . . . . . . . . . . . .151
US: 1-866-764-5454
CAN: 1-800-265-0502
15
16
17
18
19
20
. . . . . . . . . . . .116,
. . . . . . . . . . . .116,
. . . . . . . . . . . .116,
. . . . . . . . . . . .116,
. . . . . . . . . . . .116,
. . . . . . . . . . . .116,
Copyright© 2007 Cooper Crouse-Hinds
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
GLS12 . . . . . . . . . . . . . . . . . . .102
GLS12 250 . . . . . . . . . . . . . . . .102
GLS12 250C . . . . . . . . . . . . . . .102
GLS12C . . . . . . . . . . . . . . . . . .102
GLS1C . . . . . . . . . . . . . . . . . . .102
GLS2 . . . . . . . . . . . . . . . . . . . .102
H1037 . . . . . . . . . . . . . . . . . . . .104
H1037DC . . . . . . . . . . . . . . . . .104
H1038 . . . . . . . . . . . . . . . . . . . .104
H1038DC . . . . . . . . . . . . . . . . .104
H1039 . . . . . . . . . . . . . . . . . . . .104
H1039DC . . . . . . . . . . . . . . . . .104
HGLS10C . . . . . . . . . . . . . . . . .106
HGLS11 . . . . . . . . . . . . . . . .87, 106
HGLS11 250 . . . . . . . . . . . . . . .106
HGLS11 250C . . . . . . . . . . . . .106
HGLS11C . . . . . . . . . . . . . . . . .106
HGLS12 . . . . . . . . . . . . . . .87, 106
HUB6 . . . . . . . . . . . . . . .83, 87, 115
HUB7 . . . . . . . . . . . . . . .83, 87, 115
HUB8 . . . . . . . . . . . . . . .83, 87, 115
HUB9 . . . . . . . . . . . . . . .83, 87, 115
JCC1 . . . . . . . . . . . . . . . . . . . . .111
JCC2 . . . . . . . . . . . . . . . . . . . . .111
GLS2C . . . . . . . . . . . . . . . . . . .102
GLS3 . . . . . . . . . . . . . . . . . . . .102
GLS3C . . . . . . . . . . . . . . . . . . .102
GLS4 . . . . . . . . . . . . . . . . . . . .102
GLS4 10 . . . . . . . . . . . . . . . . . .102
GLS4 10C . . . . . . . . . . . . . . . . .102
H1040 . . . . . . . . . . . . . . . . . . . .104
H1040DC . . . . . . . . . . . . . . . . .104
H1041 . . . . . . . . . . . . . . . . . . . .104
H1042 . . . . . . . . . . . . . . . . . . . .104
HGLL 1 . . . . . . . . . . . . . . . . . . .104
HGLL 10 . . . . . . . . . . . . . . . . . .104
HGLS12 250 . . . . . . . . . . . . . . .106
HGLS12 250C . . . . . . . . . . . . .106
HGLS12C . . . . . . . . . . . . . . . . .106
HGLS1C . . . . . . . . . . . . . . . . . .106
HGLS2 . . . . . . . . . . . . . . . . . . .106
HGLS2C . . . . . . . . . . . . . . . . . .106
JCC34 . . . . . . . . . . . . . . . . . . . .111
JCC56 . . . . . . . . . . . . . . . . . . . .111
JCC78 . . . . . . . . . . . . . . . . . . . .111
JCC910 . . . . . . . . . . . . . . . . . . .111
K100CM . . . . . . . . . . . . . . . . . .121
K100S . . . . . . . . . . . . . . . . . . . .121
GLS4C . . . . . . . . . . . . . . . . . . .102
GLS5 . . . . . . . . . . . . . . . . . . . .102
GLS5 10 . . . . . . . . . . . . . . . . . .102
GLS5 10C . . . . . . . . . . . . . . . . .102
GLS5C . . . . . . . . . . . . . . . . . . .102
GLS6 . . . . . . . . . . . . . . . . . . . .102
HGLL
HGLL
HGLL
HGLL
HGLL
HGLL
11 . . . . . . . . . . . . . . . . . .104
11 250 . . . . . . . . . . . . . .104
11C . . . . . . . . . . . . . . . . .104
12 . . . . . . . . . . . . . . . . . .104
12 250 . . . . . . . . . . . . . .104
12 250C . . . . . . . . . . . . .104
HGLS3 . . . . . . . . . . . . . . . . . . .106
HGLS3C . . . . . . . . . . . . . . . . . .106
HGLS4 . . . . . . . . . . . . . . . . . . .106
HGLS4 10 . . . . . . . . . . . . . . . . .106
HGLS4 10C . . . . . . . . . . . . . . .106
HGLS4C . . . . . . . . . . . . . . . . . .106
K100SG . . . . . . . . . . . . . . . . . .121
K125CM . . . . . . . . . . . . . . . . . .121
K125S . . . . . . . . . . . . . . . . . . . .121
K125SG . . . . . . . . . . . . . . . . . .121
K200CM . . . . . . . . . . . . . . . . . .121
K200S . . . . . . . . . . . . . . . . . . . .121
GLS6 10 . . . . . . . . . . . . . . . . . .102
GLS6 10C . . . . . . . . . . . . . . . . .102
GLS6C . . . . . . . . . . . . . . . . . . .102
GLS7 . . . . . . . . . . . . . . . . . . . .102
GLS7 250 . . . . . . . . . . . . . . . . .102
GLS7 250C . . . . . . . . . . . . . . . .102
HGLL
HGLL
HGLL
HGLL
HGLL
HGLL
12C . . . . . . . . . . . . . . . . .104
2 . . . . . . . . . . . . . . . . . . .104
3 . . . . . . . . . . . . . . . . . . .104
4 . . . . . . . . . . . . . . . . . . .104
5 . . . . . . . . . . . . . . . . . . .104
6 . . . . . . . . . . . . . . . . . . .104
HGLS5 . . . . . . . . . . . . . . . . . . .106
HGLS5 10 . . . . . . . . . . . . . . . . .106
HGLS5 10C . . . . . . . . . . . . . . .106
HGLS5C . . . . . . . . . . . . . . . . . .106
HGLS6 . . . . . . . . . . . . . . . . . . .106
HGLS6 10 . . . . . . . . . . . . . . . . .106
K200SG . . . . . . . . . . . . . . . . . .121
K250CM . . . . . . . . . . . . . . . . . .121
K250S . . . . . . . . . . . . . . . . . . . .121
K250SG . . . . . . . . . . . . . . . . . .121
K350CM . . . . . . . . . . . . . . . . . .121
K350S . . . . . . . . . . . . . . . . . . . .121
GLS7
GLS7
GLS8
GLS8
GLS8
GLS8
30 . . . . . . . . . . . . . . . . . .102
30C . . . . . . . . . . . . . . . . .102
. . . . . . . . . . . . . . . . . . . .102
250 . . . . . . . . . . . . . . . . .102
250C . . . . . . . . . . . . . . . .102
30 . . . . . . . . . . . . . . . . . .102
HGLL 6C . . . . . . . . . . . . . . . . .104
HGLL 7 . . . . . . . . . . . . . . . . . . .104
HGLL 8 . . . . . . . . . . . . . . . . . . .104
HGLL 9 . . . . . . . . . . . . . . . . . . .104
HGLL10 250 . . . . . . . . . . . . . . .104
HGLL10 250C . . . . . . . . . . . . . .104
HGLS6 10C . . . . . . . . . . . . . . .106
HGLS6C . . . . . . . . . . . . . . . . . .106
HGLS7 . . . . . . . . . . . . . . . . . . .106
HGLS7 250 . . . . . . . . . . . . . . . .106
HGLS7 250C . . . . . . . . . . . . . .106
HGLS7 30 . . . . . . . . . . . . . . . . .106
K350SG . . . . . . . . . . . . . . . . . .121
K50CM . . . . . . . . . . . . . . . . . . .121
K50S . . . . . . . . . . . . . . . . . . . . .121
K50SG . . . . . . . . . . . . . . . . . . .121
K75CM . . . . . . . . . . . . . . . . . . .121
K75S . . . . . . . . . . . . . . . . . . . . .121
GLS8 30C . . . . . . . . . . . . . . . . .102
GLS8C . . . . . . . . . . . . . . . . . . .102
GLS9 . . . . . . . . . . . . . . . . . . . .102
GLS9 250 . . . . . . . . . . . . . . . . .102
GLS9 250C . . . . . . . . . . . . . . . .102
GLS9C . . . . . . . . . . . . . . . . . . .102
HGLL10C . . . . . . . . . . . . . . . . .104
HGLL11 250C . . . . . . . . . . . . . .104
HGLL1C . . . . . . . . . . . . . . . . . .104
HGLL2C . . . . . . . . . . . . . . . . . .104
HGLL3C . . . . . . . . . . . . . . . . . .104
HGLL4 10 . . . . . . . . . . . . . . . . .104
HGLS7 30C . . . . . . . . . . . . . . .106
HGLS7C . . . . . . . . . . . . . . .87, 106
HGLS8 . . . . . . . . . . . . . . . . . . .106
HGLS8 250 . . . . . . . . . . . . . . . .106
HGLS8 250C . . . . . . . . . . . . . .106
HGLS8 30 . . . . . . . . . . . . . . . . .106
K75SG . . . . . . . . . . . . . . . . . . .121
LB100M . . . . . . . . . . . . . . . . . .121
LB105 . . . . . . . . . . . . . . . . . . . .117
LB105 MT . . . . . . . . . . . . . . . . .116
LB125M . . . . . . . . . . . . . . . . . .121
LB15 . . . . . . . . . . . . . . . . . . . . .117
H
H
H
H
H
H
931
932
933
934
935
936
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
HGLL4 10C . . . . . . . . . . . . . . . .104
HGLL4C . . . . . . . . . . . . . . . . . .104
HGLL5 10 . . . . . . . . . . . . . . . . .104
HGLL5 10C . . . . . . . . . . . . . . . .104
HGLL5C . . . . . . . . . . . . . . . . . .104
HGLL6 10 . . . . . . . . . . . . . . . . .104
HGLS8 30C . . . . . . . . . . . . . . .106
HGLS8C . . . . . . . . . . . . . . . . . .106
HGLS9 . . . . . . . . . . . . . . . . . . .106
HGLS9 250 . . . . . . . . . . . . . . . .106
HGLS9 250C . . . . . . . . . . . . . .106
HGLS9C . . . . . . . . . . . . . . . . . .106
LB15 MT . . . . . . . . . . . . . . . . . .116
LB150M . . . . . . . . . . . . . . . . . .121
LB200M . . . . . . . . . . . . . . . . . .121
LB25 . . . . . . . . . . . . . . . . . . . . .117
LB25 MT . . . . . . . . . . . . . . . . . .116
LB250M . . . . . . . . . . . . . . . . . .121
H
H
H
H
H
H
937
938
939
940
941
942
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . . .104
HGLL6 10C . . . . . . . . . . . . . . . .104
HGLL7 250 . . . . . . . . . . . . . . . .104
HGLL7 250C . . . . . . . . . . . . . .104
HGLL7 30 . . . . . . . . . . . . . . . . .104
HGLL7 30C . . . . . . . . . . . . . . .104
HGLL7C . . . . . . . . . . . . . . . . . .104
HS1031
HS1032
HS1033
HS1034
HS1035
HS1036
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
LB300M . . . . . . . . . . . . . . . . . .121
LB35 . . . . . . . . . . . . . . . . . . . . .117
LB35 MT . . . . . . . . . . . . . . . . . .116
LB350M . . . . . . . . . . . . . . . . . .121
LB400M . . . . . . . . . . . . . . . . . .121
LB45 . . . . . . . . . . . . . . . . . . . . .117
H1031 . . . . . . . . . . . . . . . . . . . .104
H1031DC . . . . . . . . . . . . . . . . .104
H1032 . . . . . . . . . . . . . . . . . . . .104
H1032DC . . . . . . . . . . . . . . . . .104
H1033 . . . . . . . . . . . . . . . . . . . .104
H1033DC . . . . . . . . . . . . . . . . .104
HGLL8 250 . . . . . . . . . . . . . . . .104
HGLL8 250C . . . . . . . . . . . . . .104
HGLL8 30 . . . . . . . . . . . . . . . . .104
HGLL8 30C . . . . . . . . . . . . . . .104
HGLL8C . . . . . . . . . . . . . . . . . .104
HGLL9 250 . . . . . . . . . . . . . . . .104
HS1037
HS1038
HS1039
HS1040
HS1041
HS1042
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
. . . . . . . . . . . . . . . . . . .104
LB45 MT . . . . . . . . . . . . . . . . . .116
LB50M . . . . . . . . . . . . . . . . . . .121
LB55 . . . . . . . . . . . . . . . . . . . . .117
LB55 MT . . . . . . . . . . . . . . . . . .116
LB65 . . . . . . . . . . . . . . . . . . . . .117
LB65 MT . . . . . . . . . . . . . . . . . .116
H1034 . . . . . . . . . . . . . . . . . . . .104
H1034DC . . . . . . . . . . . . . . . . .104
H1035 . . . . . . . . . . . . . . . . . . . .104
H1035DC . . . . . . . . . . . . . . . . .104
H1036 . . . . . . . . . . . . . . . . . . . .104
H1036DC . . . . . . . . . . . . . . . . .104
HGLL9 250C . . . . . . . . . . . . . .104
HGLL9C . . . . . . . . . . . . . . . . . .104
HGLS1 . . . . . . . . . . . . . . . . . . .106
HGLS10 . . . . . . . . . . . . . . . . . .106
HGLS10 250 . . . . . . . . . . . . . . .106
HGLS10 250C . . . . . . . . . . . . .106
HUB1 . . . . . . . . . . . . . . . . .83,
HUB10 . . . . . . . . . . . . . . . .83,
HUB2 . . . . . . . . . . . . . . . . .83,
HUB3 . . . . . . . . . . . . . . .83, 87,
HUB4 . . . . . . . . . . . . . . .83, 87,
HUB5 . . . . . . . . . . . . . . .83, 87,
US: 1-866-764-5454
CAN: 1-800-265-0502
115
115
115
115
115
115
Copyright© 2007 Cooper Crouse-Hinds
LB75 . . . . . . . . . . . . . . . . . . . . .117
LB75 MT . . . . . . . . . . . . . . . . . .116
LB75M . . . . . . . . . . . . . . . . . . .121
LB85 . . . . . . . . . . . . . . . . . . . . .117
LB85 MT . . . . . . . . . . . . . . . . . .116
LB95 . . . . . . . . . . . . . . . . . . . . .117
175
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
LB95 MT . . . . . . . . . . . . . . . . . .116
LL100M . . . . . . . . . . . . . . . . . . .121
LL105 . . . . . . . . . . . . . . . . . . . .117
LL125M . . . . . . . . . . . . . . . . . . .121
LL15 . . . . . . . . . . . . . . . . . . . . .117
LL15 MT . . . . . . . . . . . . . . . . . .116
LT10090G SA . . . . . . . . . . . . . .129
LT10090NM . . . . . . . . . . . . . . .135
LT100DC . . . . . . . . . . . . . . . . . .127
LT100G . . . . . . . . . . . . . . . . . . .128
LT100G SA . . . . . . . . . . . . . . . .128
LT100NM . . . . . . . . . . . . . . . . .135
LT35090 . . . . . . . . . . . . . . . . . .126
LT35090DC . . . . . . . . . . . . . . .127
LT35090G . . . . . . . . . . . . . . . . .129
LT350DC . . . . . . . . . . . . . . . . .127
LT350G . . . . . . . . . . . . . . . . . . .128
LT350G SA . . . . . . . . . . . . . . . .128
LTB10090 . . . . . . . . . . . . . . . . .126
LTB10090DC . . . . . . . . . . . . . .127
LTB10090G . . . . . . . . . . . . . . . .129
LTB10090GC . . . . . . . . . . . . . .129
LTB100DC . . . . . . . . . . . . . . . .127
LTB100G . . . . . . . . . . . . . . . . . .128
LL150M . . . . . . . . . . . . . . . . . . .121
LL200M . . . . . . . . . . . . . . . . . .121
LL25 . . . . . . . . . . . . . . . . . . . . .117
LL25 MT . . . . . . . . . . . . . . . . . .116
LL250M . . . . . . . . . . . . . . . . . .121
LL300M . . . . . . . . . . . . . . . . . .121
LT125 . . . . . . . . . . . . . . . . . . . .125
LT125 SA . . . . . . . . . . . . . . . . .126
LT12545 . . . . . . . . . . . . . . . . . .126
LT12590 . . . . . . . . . . . . . . . . . .126
LT12590 SA . . . . . . . . . . . . . . .126
LT12590DC . . . . . . . . . . . . . . . .127
LT38 . . . . . . . . . . . . . . . . . . . . .125
LT38 SA . . . . . . . . . . . . . . . . . .126
LT3845 . . . . . . . . . . . . . . . . . . .126
LT3890 . . . . . . . . . . . . . . . . . . .126
LT3890 SA . . . . . . . . . . . . . . . .126
LT3890DC . . . . . . . . . . . . . . . .127
LTB100GC . . . . . . . . . . . . . . . .129
LTB125 . . . . . . . . . . . . . . . . . . .125
LTB12545 . . . . . . . . . . . . . . . . .126
LTB12545G . . . . . . . . . . . . . . . .129
LTB12545GC . . . . . . . . . . . . . .129
LTB12590 . . . . . . . . . . . . . . . . .126
LL35 . . . . . . . . . . . . . . . . . . . . .117
LL35 MT . . . . . . . . . . . . . . . . . .116
LL350M . . . . . . . . . . . . . . . . . .121
LL400M . . . . . . . . . . . . . . . . . .121
LL45 . . . . . . . . . . . . . . . . . . . . .117
LL45 MT . . . . . . . . . . . . . . . . . .116
LT12590G . . . . . . . . . . . . . . . . .129
LT12590G SA . . . . . . . . . . . . . .129
LT125DC . . . . . . . . . . . . . . . . . .127
LT125G . . . . . . . . . . . . . . . . . . .128
LT125G SA . . . . . . . . . . . . . . . .128
LT150 . . . . . . . . . . . . . . . . . . . .125
LT3890G . . . . . . . . . . . . . . . . . .129
LT3890G SA . . . . . . . . . . . . . . .129
LT38DC . . . . . . . . . . . . . . . . . .127
LT38G . . . . . . . . . . . . . . . . . . . .128
LT38G SA . . . . . . . . . . . . . . . . .128
LT400 . . . . . . . . . . . . . . . . . . . .125
LTB12590DC . . . . . . . . . . . . . .127
LTB12590G . . . . . . . . . . . . . . . .129
LTB12590GC . . . . . . . . . . . . . .129
LTB125DC . . . . . . . . . . . . . . . .127
LTB125G . . . . . . . . . . . . . . . . . .128
LTB125GC . . . . . . . . . . . . . . . .129
LL50M . . . . . . . . . . . . . . . . . . .121
LL55 . . . . . . . . . . . . . . . . . . . . .117
LL55 MT . . . . . . . . . . . . . . . . . .116
LL65 . . . . . . . . . . . . . . . . . . . . .117
LL65 MT . . . . . . . . . . . . . . . . . .116
LL75 . . . . . . . . . . . . . . . . . . . . .117
LT150 SA . . . . . . . . . . . . . . . . .126
LT15045 . . . . . . . . . . . . . . . . . .126
LT15090 . . . . . . . . . . . . . . . . . .126
LT15090 SA . . . . . . . . . . . . . . .126
LT15090DC . . . . . . . . . . . . . . . .127
LT15090G . . . . . . . . . . . . . . . . .129
LT400 SA . . . . . . . . . . . . . . . . .126
LT40045 . . . . . . . . . . . . . . . . . .126
LT40090 . . . . . . . . . . . . . . . . . .126
LT40090DC . . . . . . . . . . . . . . .127
LT40090G . . . . . . . . . . . . . . . . .129
LT400DC . . . . . . . . . . . . . . . . .127
LTB150 . . . . . . . . . . . . . . . . . . .125
LTB15045 . . . . . . . . . . . . . . . . .126
LTB15045G . . . . . . . . . . . . . . . .129
LTB15045GC . . . . . . . . . . . . . .129
LTB15090 . . . . . . . . . . . . . . . . .126
LTB15090DC . . . . . . . . . . . . . .127
LL75M . . . . . . . . . . . . . . . . . . .121
LL85 . . . . . . . . . . . . . . . . . . . . .117
LL95 . . . . . . . . . . . . . . . . . . . . .117
LR100M . . . . . . . . . . . . . . . . . .121
LR105 . . . . . . . . . . . . . . . . . . . .117
LR125M . . . . . . . . . . . . . . . . . .121
LT15090G SA . . . . . . . . . . . . . .129
LT150DC . . . . . . . . . . . . . . . . . .127
LT150G . . . . . . . . . . . . . . . . . . .128
LT150G SA . . . . . . . . . . . . . . . .128
LT200 . . . . . . . . . . . . . . . . . . . .125
LT200 SA . . . . . . . . . . . . . . . . .126
LT400G . . . . . . . . . . . . . . . . . . .128
LT400G SA . . . . . . . . . . . . . . . .128
LT50 . . . . . . . . . . . . . . . . . . . . .125
LT50 SA . . . . . . . . . . . . . . . . . .126
LT500 . . . . . . . . . . . . . . . . . . . .125
LT500G . . . . . . . . . . . . . . . . . . .128
LTB15090G . . . . . . . . . . . . . . . .129
LTB15090GC . . . . . . . . . . . . . .129
LTB150DC . . . . . . . . . . . . . . . .127
LTB150G . . . . . . . . . . . . . . . . . .128
LTB150GC . . . . . . . . . . . . . . . .129
LTB200 . . . . . . . . . . . . . . . . . . .125
LR15 . . . . . . . . . . . . . . . . . . . . .117
LR15 MT . . . . . . . . . . . . . . . . . .116
LR150M . . . . . . . . . . . . . . . . . .121
LR200M . . . . . . . . . . . . . . . . . .121
LR25 . . . . . . . . . . . . . . . . . . . . .117
LR25 MT . . . . . . . . . . . . . . . . . .116
LT20045 . . . . . . . . . . . . . . . . . .126
LT20090 . . . . . . . . . . . . . . . . . .126
LT20090 SA . . . . . . . . . . . . . . .126
LT20090DC . . . . . . . . . . . . . . .127
LT20090G . . . . . . . . . . . . . . . . .129
LT20090G SA . . . . . . . . . . . . . .129
LT5045 . . . . . . . . . . . . . . . . . . .126
LT5090 . . . . . . . . . . . . . . . . . . .126
LT5090 SA . . . . . . . . . . . . . . . .126
LT5090DC . . . . . . . . . . . . . . . .127
LT5090G . . . . . . . . . . . . . . . . . .129
LT5090G SA . . . . . . . . . . . . . . .129
LTB20045 . . . . . . . . . . . . . . . . .126
LTB20045G . . . . . . . . . . . . . . .129
LTB20045GC . . . . . . . . . . . . . .129
LTB20090 . . . . . . . . . . . . . . . . .126
LTB20090DC . . . . . . . . . . . . . .127
LTB20090G . . . . . . . . . . . . . . .129
LR250M . . . . . . . . . . . . . . . . . .121
LR300M . . . . . . . . . . . . . . . . . .121
LR35 . . . . . . . . . . . . . . . . . . . . .117
LR35 MT . . . . . . . . . . . . . . . . . .116
LR350M . . . . . . . . . . . . . . . . . .121
LR400M . . . . . . . . . . . . . . . . . .121
LT200DC . . . . . . . . . . . . . . . . .127
LT200G . . . . . . . . . . . . . . . . . . .128
LT200G SA . . . . . . . . . . . . . . . .128
LT250 . . . . . . . . . . . . . . . . . . . .125
LT250 SA . . . . . . . . . . . . . . . . .126
LT25045 . . . . . . . . . . . . . . . . . .126
LT5090NM . . . . . . . . . . . . . . . .135
LT50DC . . . . . . . . . . . . . . . . . .127
LT50G . . . . . . . . . . . . . . . . . . . .128
LT50G SA . . . . . . . . . . . . . . . . .128
LT50NM . . . . . . . . . . . . . . . . . .135
LT600 . . . . . . . . . . . . . . . . . . . .125
LTB20090GC . . . . . . . . . . . . . .129
LTB200DC . . . . . . . . . . . . . . . .127
LTB200G . . . . . . . . . . . . . . . . .128
LTB200GC . . . . . . . . . . . . . . . .129
LTB250 . . . . . . . . . . . . . . . . . . .125
LTB25045 . . . . . . . . . . . . . . . . .126
LR45 . . . . . . . . . . . . . . . . . . . . .117
LR45 MT . . . . . . . . . . . . . . . . . .116
LR50M . . . . . . . . . . . . . . . . . . .121
LR55 . . . . . . . . . . . . . . . . . . . . .117
LR55 MT . . . . . . . . . . . . . . . . . .116
LR65 . . . . . . . . . . . . . . . . . . . . .117
LT25090 . . . . . . . . . . . . . . . . . .126
LT25090DC . . . . . . . . . . . . . . .127
LT25090G . . . . . . . . . . . . . . . . .129
LT250DC . . . . . . . . . . . . . . . . .127
LT250G . . . . . . . . . . . . . . . . . . .128
LT250G SA . . . . . . . . . . . . . . . .128
LT600G . . . . . . . . . . . . . . . . . . .128
LT75 . . . . . . . . . . . . . . . . . . . . .125
LT75 SA . . . . . . . . . . . . . . . . . .126
LT7545 . . . . . . . . . . . . . . . . . . .126
LT7590 . . . . . . . . . . . . . . . . . . .126
LT7590 SA . . . . . . . . . . . . . . . .126
LTB25045G . . . . . . . . . . . . . . .129
LTB25045GC . . . . . . . . . . . . . .129
LTB25090 . . . . . . . . . . . . . . . . .126
LTB25090DC . . . . . . . . . . . . . .127
LTB25090G . . . . . . . . . . . . . . .129
LTB25090GC . . . . . . . . . . . . . .129
LR65 MT . . . . . . . . . . . . . . . . . .116
LR75 . . . . . . . . . . . . . . . . . . . . .117
LR75M . . . . . . . . . . . . . . . . . . .121
LR85 . . . . . . . . . . . . . . . . . . . . .117
LR95 . . . . . . . . . . . . . . . . . . . . .117
LT100 . . . . . . . . . . . . . . . . . . . .125
LT300 . . . . . . . . . . . . . . . . . . . .125
LT300 SA . . . . . . . . . . . . . . . . .126
LT30045 . . . . . . . . . . . . . . . . . .126
LT30090 . . . . . . . . . . . . . . . . . .126
LT30090DC . . . . . . . . . . . . . . .127
LT30090G . . . . . . . . . . . . . . . . .129
LT7590DC . . . . . . . . . . . . . . . .127
LT7590G . . . . . . . . . . . . . . . . . .129
LT7590G SA . . . . . . . . . . . . . . .129
LT7590NM . . . . . . . . . . . . . . . .135
LT75DC . . . . . . . . . . . . . . . . . .127
LT75G . . . . . . . . . . . . . . . . . . . .128
LTB250DC . . . . . . . . . . . . . . . .127
LTB250G . . . . . . . . . . . . . . . . .128
LTB250GC . . . . . . . . . . . . . . . .129
LTB300 . . . . . . . . . . . . . . . . . . .125
LTB30045 . . . . . . . . . . . . . . . . .126
LTB30045G . . . . . . . . . . . . . . .129
LT100 SA . . . . . . . . . . . . . . . . .126
LT10045 . . . . . . . . . . . . . . . . . .126
LT10090 . . . . . . . . . . . . . . . . . .126
LT10090 SA . . . . . . . . . . . . . . .126
LT10090DC . . . . . . . . . . . . . . . .127
LT10090G . . . . . . . . . . . . . . . . .129
LT300DC . . . . . . . . . . . . . . . . .127
LT300G . . . . . . . . . . . . . . . . . . .128
LT300G SA . . . . . . . . . . . . . . . .128
LT350 . . . . . . . . . . . . . . . . . . . .125
LT350 SA . . . . . . . . . . . . . . . . .126
LT35045 . . . . . . . . . . . . . . . . . .126
LT75G SA . . . . . . . . . . . . . . . . .128
LT75NM . . . . . . . . . . . . . . . . . .135
LTB100 . . . . . . . . . . . . . . . . . . .125
LTB10045 . . . . . . . . . . . . . . . . .126
LTB10045G . . . . . . . . . . . . . . . .129
LTB10045GC . . . . . . . . . . . . . .129
LTB30045GC . . . . . . . . . . . . . .129
LTB30090 . . . . . . . . . . . . . . . . .126
LTB30090DC . . . . . . . . . . . . . .127
LTB30090G . . . . . . . . . . . . . . .129
LTB30090GC . . . . . . . . . . . . . .129
LTB300DC . . . . . . . . . . . . . . . .127
176
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
LTB300G . . . . . . . . . . . . . . . . .128
LTB300GC . . . . . . . . . . . . . . . .129
LTB350 . . . . . . . . . . . . . . . . . . .125
LTB35045 . . . . . . . . . . . . . . . . .126
LTB35045G . . . . . . . . . . . . . . .129
LTB35045GC . . . . . . . . . . . . . .129
LTB75GC . . . . . . . . . . . . . . . . .129
LTBK100 . . . . . . . . . . . . . . . . . .133
LTBK10045 . . . . . . . . . . . . . . . .133
LTBK10090 . . . . . . . . . . . . . . . .133
LTBK125 . . . . . . . . . . . . . . . . . .133
LTBK12545 . . . . . . . . . . . . . . . .133
LTQB200 . . . . . . . . . . . . . . . . .132
LTQB38 . . . . . . . . . . . . . . . . . .132
LTQB50 . . . . . . . . . . . . . . . . . .132
LTQB75 . . . . . . . . . . . . . . . . . .132
LTQF100 . . . . . . . . . . . . . . . . . .132
LTQF125 . . . . . . . . . . . . . . . . . .132
PLG1M . . . . . . . . . . . . . . . . . . .113
PLG25M . . . . . . . . . . . . . . . . . .113
PLG2M . . . . . . . . . . . . . . . . . . .113
PLG35M . . . . . . . . . . . . . . . . . .113
PLG3M . . . . . . . . . . . . . . . . . . .113
PLG45M . . . . . . . . . . . . . . . . . .113
LTB35090 . . . . . . . . . . . . . . . . .126
LTB35090DC . . . . . . . . . . . . . .127
LTB35090G . . . . . . . . . . . . . . .129
LTB35090GC . . . . . . . . . . . . . .129
LTB350DC . . . . . . . . . . . . . . . .127
LTB350G . . . . . . . . . . . . . . . . .128
LTBK12590 . . . . . . . . . . . . . . . .133
LTBK150 . . . . . . . . . . . . . . . . . .133
LTBK15045 . . . . . . . . . . . . . . . .133
LTBK15090 . . . . . . . . . . . . . . . .133
LTBK200 . . . . . . . . . . . . . . . . . .133
LTBK20045 . . . . . . . . . . . . . . . .133
LTQF150 . . . . . . . . . . . . . . . . . .132
LTQF200 . . . . . . . . . . . . . . . . . .132
LTQF38 . . . . . . . . . . . . . . . . . . .132
LTQF50 . . . . . . . . . . . . . . . . . . .132
LTQF75 . . . . . . . . . . . . . . . . . . .132
LTR100 . . . . . . . . . . . . . . . . . . .126
PLG4M . . . . . . . . . . . . . . . . . . .113
PLG55M . . . . . . . . . . . . . . . . . .113
PLG5M . . . . . . . . . . . . . . . . . . .113
PLG65M . . . . . . . . . . . . . . . . . .113
PLG6M . . . . . . . . . . . . . . . . . . .113
PLG75M . . . . . . . . . . . . . . . . . .113
LTB350GC . . . . . . . . . . . . . . . .129
LTB38 . . . . . . . . . . . . . . . . . . . .125
LTB3845 . . . . . . . . . . . . . . . . . .126
LTB3845G . . . . . . . . . . . . . . . .129
LTB3845GC . . . . . . . . . . . . . . .129
LTB3890 . . . . . . . . . . . . . . . . . .126
LTBK20090 . . . . . . . . . . . . . . . .133
LTBK38 . . . . . . . . . . . . . . . . . . .133
LTBK3845 . . . . . . . . . . . . . . . . .133
LTBK3890 . . . . . . . . . . . . . . . . .133
LTBK50 . . . . . . . . . . . . . . . . . . .133
LTBK5045 . . . . . . . . . . . . . . . . .133
LTR100G . . . . . . . . . . . . . . . . .131
LTR125 . . . . . . . . . . . . . . . . . . .126
LTR125G . . . . . . . . . . . . . . . . .131
LTR150 . . . . . . . . . . . . . . . . . . .126
LTR150G . . . . . . . . . . . . . . . . .131
LTR200 . . . . . . . . . . . . . . . . . . .126
PLG7M . . . . . . . . . . . . . . . . . . .113
PLG85M . . . . . . . . . . . . . . . . . .113
PLG8M . . . . . . . . . . . . . . . . . . .113
PLG95M . . . . . . . . . . . . . . . . . .113
PLG9M . . . . . . . . . . . . . . . . . . .113
PPC 100 . . . . . . . . . . . . . . . . . .108
LTB3890DC . . . . . . . . . . . . . . .127
LTB3890G . . . . . . . . . . . . . . . .129
LTB3890GC . . . . . . . . . . . . . . .129
LTB38DC . . . . . . . . . . . . . . . . .127
LTB38G . . . . . . . . . . . . . . . . . .128
LTB38GC . . . . . . . . . . . . . . . . .129
LTBK5090 . . . . . . . . . . . . . . . . .133
LTBK75 . . . . . . . . . . . . . . . . . . .133
LTBK7545 . . . . . . . . . . . . . . . . .133
LTBK7590 . . . . . . . . . . . . . . . . .133
LTK100 . . . . . . . . . . . . . . . . . . .133
LTK10045 . . . . . . . . . . . . . . . . .133
LTR200G . . . . . . . . . . . . . . . . .131
LTR38 . . . . . . . . . . . . . . . . . . . .126
LTR38G . . . . . . . . . . . . . . . . . .131
LTR50 . . . . . . . . . . . . . . . . . . . .126
LTR50G . . . . . . . . . . . . . . . . . .131
LTR75 . . . . . . . . . . . . . . . . . . . .126
PPC
PPC
PPC
PPC
PPC
PPC
LTB400 . . . . . . . . . . . . . . . . . . .125
LTB40045 . . . . . . . . . . . . . . . . .126
LTB40045G . . . . . . . . . . . . . . .129
LTB40045GC . . . . . . . . . . . . . .129
LTB40090 . . . . . . . . . . . . . . . . .126
LTB40090DC . . . . . . . . . . . . . .127
LTK10090 . . . . . . . . . . . . . . . . .133
LTK125 . . . . . . . . . . . . . . . . . . .133
LTK12545 . . . . . . . . . . . . . . . . .133
LTK12590 . . . . . . . . . . . . . . . . .133
LTK150 . . . . . . . . . . . . . . . . . . .133
LTK15045 . . . . . . . . . . . . . . . . .133
LTR75G . . . . . . . . . . . . . . . . . .131
MHUB1 . . . . . . . . . . . . . . . .87, 115
MHUB10 . . . . . . . . . . . . . . .87, 115
MHUB11 . . . . . . . . . . . . . . .87, 115
MHUB12 . . . . . . . . . . . . . . .87, 115
MHUB2 . . . . . . . . . . . . . . . .87, 115
PPC 400 . . . . . . . . . . . . . . . . . .108
PPC 50 . . . . . . . . . . . . . . . . . . .108
PPC 75 . . . . . . . . . . . . . . . . . . .108
QLK50D . . . . . . . . . . . . . .141, 145
QLK50S . . . . . . . . . . . . . .141, 145
QLK75 . . . . . . . . . . . . . . .141, 145
LTB40090G . . . . . . . . . . . . . . .129
LTB40090GC . . . . . . . . . . . . . .129
LTB400DC . . . . . . . . . . . . . . . .127
LTB400G . . . . . . . . . . . . . . . . .128
LTB400GC . . . . . . . . . . . . . . . .129
LTB50 . . . . . . . . . . . . . . . . . . . .125
LTK15090 . . . . . . . . . . . . . . . . .133
LTK200 . . . . . . . . . . . . . . . . . . .133
LTK20045 . . . . . . . . . . . . . . . . .133
LTK20090 . . . . . . . . . . . . . . . . .133
LTK38 . . . . . . . . . . . . . . . . . . . .133
LTK3845 . . . . . . . . . . . . . . . . . .133
MHUB3
MHUB4
MHUB5
MHUB6
MHUB7
MHUB8
RAC100HD
RAC125HD
RAC150HD
RAC200HD
RAC250HD
RAC300HD
LTB500 . . . . . . . . . . . . . . . . . . .125
LTB500G . . . . . . . . . . . . . . . . .128
LTB5045 . . . . . . . . . . . . . . . . . .126
LTB5045G . . . . . . . . . . . . . . . .129
LTB5045GC . . . . . . . . . . . . . . .129
LTB5090 . . . . . . . . . . . . . . . . . .126
LTK3890 . . . . . . . . . . . . . . . . . .133
LTK50 . . . . . . . . . . . . . . . . . . . .133
LTK5045 . . . . . . . . . . . . . . . . . .133
LTK5090 . . . . . . . . . . . . . . . . . .133
LTK75 . . . . . . . . . . . . . . . . . . . .133
LTK7545 . . . . . . . . . . . . . . . . . .133
MHUB9 . . . . . . . . . . . . . . . .87, 115
NCG100 100 . . . . . . . . . . . . . . .136
NCG38 35 . . . . . . . . . . . . . . . .136
NCG50 50 . . . . . . . . . . . . . . . .136
NCG75 75 . . . . . . . . . . . . . . . .136
NS 1 . . . . . . . . . . . . . . . . . .95, 109
RAC350HD . . . . . . . . . . . . . . . .111
RAC400HD . . . . . . . . . . . . . . . .111
RAC50HD . . . . . . . . . . . . . . . . .111
RAC75HD . . . . . . . . . . . . . . . . .111
S 1 1/2 . . . . . . . . . . . . . . . . .74, 88
S 1 3/8 . . . . . . . . . . . . . . . . .74, 88
LTB5090DC . . . . . . . . . . . . . . .127
LTB5090G . . . . . . . . . . . . . . . .129
LTB5090GC . . . . . . . . . . . . . . .129
LTB50DC . . . . . . . . . . . . . . . . .127
LTB50G . . . . . . . . . . . . . . . . . .128
LTB50GC . . . . . . . . . . . . . . . . .129
LTK7590 . . . . . . . . . . . . . . . . . .133
LTKF100 . . . . . . . . . . . . . . . . . .133
LTKF125 . . . . . . . . . . . . . . . . . .133
LTKF150 . . . . . . . . . . . . . . . . . .133
LTKF200 . . . . . . . . . . . . . . . . . .133
LTKF38 . . . . . . . . . . . . . . . . . . .133
NS 2 . . . . . . . . . . . . . . . . . .95, 109
NS 3 . . . . . . . . . . . . . . . . . .95, 109
NSS1 . . . . . . . . . . . . . . . . .95, 109
NSS2 . . . . . . . . . . . . . . . . .95, 109
NSS3 . . . . . . . . . . . . . . . . .95, 109
PARC100HD . . . . . . . . . . . . . . .111
S1031
S1032
S1033
S1034
S1035
S1036
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
LTB600 . . . . . . . . . . . . . . . . . . .125
LTB600G . . . . . . . . . . . . . . . . .128
LTB75 . . . . . . . . . . . . . . . . . . . .125
LTB7545 . . . . . . . . . . . . . . . . . .126
LTB7545G . . . . . . . . . . . . . . . .129
LTB7545GC . . . . . . . . . . . . . . .129
LTKF50
LTKF75
LTQ100
LTQ125
LTQ150
LTQ200
PARC125HD
PARC150HD
PARC200HD
PARC250HD
PARC300HD
PARC350HD
S1037
S1038
S1039
S1040
S1041
S1042
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
. . . . . . . . . . . . . . . . . . . .100
LTB7590 . . . . . . . . . . . . . . . . . .126
LTB7590DC . . . . . . . . . . . . . . .127
LTB7590G . . . . . . . . . . . . . . . .129
LTB7590GC . . . . . . . . . . . . . . .129
LTB75DC . . . . . . . . . . . . . . . . .127
LTB75G . . . . . . . . . . . . . . . . . .128
LTQ38 . . . . . . . . . . . . . . . . . . . .132
LTQ50 . . . . . . . . . . . . . . . . . . . .132
LTQ75 . . . . . . . . . . . . . . . . . . . .132
LTQB100 . . . . . . . . . . . . . . . . . .132
LTQB125 . . . . . . . . . . . . . . . . . .132
LTQB150 . . . . . . . . . . . . . . . . . .132
. . . . . . . . . . . . . . . . . . .133
. . . . . . . . . . . . . . . . . . .133
. . . . . . . . . . . . . . . . . . .132
. . . . . . . . . . . . . . . . . . .132
. . . . . . . . . . . . . . . . . . .132
. . . . . . . . . . . . . . . . . . .132
US: 1-866-764-5454
CAN: 1-800-265-0502
. . . . . . . . . . . . . . . .87,
. . . . . . . . . . . . . . . .87,
. . . . . . . . . . . . . . . .87,
. . . . . . . . . . . . . . . .87,
. . . . . . . . . . . . . . . .87,
. . . . . . . . . . . . . . . .87,
115
115
115
115
115
115
. . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . .111
PARC400HD . . . . . . . . . . . . . . .111
PARC50HD . . . . . . . . . . . . . . . .111
PARC75HD . . . . . . . . . . . . . . . .111
PLG105M . . . . . . . . . . . . . . . . .113
PLG10M . . . . . . . . . . . . . . . . . .113
PLG15M . . . . . . . . . . . . . . . . . .113
Copyright© 2007 Cooper Crouse-Hinds
125
150
200
250
300
350
. . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . . . .108
. . . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . . .111
. . . . . . . . . . . . . . . .111
SA 1W . . . . . . . . . . . . . . . . .74, 88
SG1 . . . . . . . . . . . . . . . . . . . . .126
SG10 . . . . . . . . . . . . . . . . . . . .126
SG11 . . . . . . . . . . . . . . . . . . . . .126
SG12 . . . . . . . . . . . . . . . . . . . .126
SG2 . . . . . . . . . . . . . . . . . . . . .126
177
Catalog
Number
SG3
SG4
SG5
SG6
SG7
SG8
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
. . . . . . . . . . . . . . . . . . . . .126
. . . . . . . . . . . . . . . . . . . . .126
. . . . . . . . . . . . . . . . . . . . .126
. . . . . . . . . . . . . . . . . . . . .126
. . . . . . . . . . . . . . . . . . . . .126
. . . . . . . . . . . . . . . . . . . . .126
SSTG 5 . . . . . . . . . . . . . . . . . . .81
SSTG 6 . . . . . . . . . . . . . . . . . . .81
SSTG 7 . . . . . . . . . . . . . . . . . . .81
SSTG 8 . . . . . . . . . . . . . . . . . . .81
SSTG 9 . . . . . . . . . . . . . . . . . . .81
SSTGK 1 . . . . . . . . . . . . . . . . . .82
STAGN 2 . . . . . . . . . . . . . . . . . .82
STAGN 3 . . . . . . . . . . . . . . . . . .82
STAGN 4 . . . . . . . . . . . . . . . . . .82
STAGN 5 . . . . . . . . . . . . . . . . . .82
STAGN 6 . . . . . . . . . . . . . . . . . .82
STC 1 . . . . . . . . . . . . . . . . . . . . .82
STTTB 2 . . . . . . . . . . . . . . . . . . .83
STTTB 3 . . . . . . . . . . . . . . . . . . .83
STTTB 4 . . . . . . . . . . . . . . . . . . .83
STTTB 5 . . . . . . . . . . . . . . . . . . .83
STTTB 6 . . . . . . . . . . . . . . . . . . .83
STTTBA 1 . . . . . . . . . . . . . . . . .83
SG9 . . . . . . . . . . . . . . . . . . . . .126
SL1 . . . . . . . . . . . . . . . . . . . . . .124
SL10 . . . . . . . . . . . . . . . . . . . . .124
SL11 . . . . . . . . . . . . . . . . . . . . .124
SL12 . . . . . . . . . . . . . . . . . . . . .124
SL2 . . . . . . . . . . . . . . . . . . . . . .124
SSTGK 2 . . . . . . . . . . . . . . . . . .82
SSTGK 3 . . . . . . . . . . . . . . . . . .82
SSTGK 4 . . . . . . . . . . . . . . . . . .82
SSTGK 5 . . . . . . . . . . . . . . . . . .82
SSTGK 6 . . . . . . . . . . . . . . . . . .82
SSTM 1 . . . . . . . . . . . . . . . . . . .83
STC 2
STC 3
STC 4
STC 5
STC 6
STG 1
. . . . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . . . .82
STTTBA 2 . . . . . . . . . . . . . . . . .83
STTTBA 3 . . . . . . . . . . . . . . . . .83
STTTBA 4 . . . . . . . . . . . . . . . . .83
STTTBA 5 . . . . . . . . . . . . . . . . .83
STTTBA 6 . . . . . . . . . . . . . . . . .83
T100M . . . . . . . . . . . . . . . . . . .121
SL3
SL4
SL5
SL6
SL7
SL8
SSTM
SSTM
SSTM
SSTM
SSTM
ST 03
STG
STG
STG
STG
STG
STG
10 . . . . . . . . . . . . . . . . . . . .82
11 . . . . . . . . . . . . . . . . . . . .82
12 . . . . . . . . . . . . . . . . . . . .82
2 . . . . . . . . . . . . . . . . . . . . .82
3 . . . . . . . . . . . . . . . . . . . . .82
4 . . . . . . . . . . . . . . . . . . . . .82
T105 . . . . . . . . . . . . . . . . . . . . .117
T125M . . . . . . . . . . . . . . . . . . .121
T15 . . . . . . . . . . . . . . . . . . . . . .117
T15 MT . . . . . . . . . . . . . . . . . . .116
T150M . . . . . . . . . . . . . . . . . . .121
T200M . . . . . . . . . . . . . . . . . . .121
. . . . . . . . . . . . . . . . . . . . . .124
. . . . . . . . . . . . . . . . . . . . . .124
. . . . . . . . . . . . . . . . . . . . . .124
. . . . . . . . . . . . . . . . . . . . . .124
. . . . . . . . . . . . . . . . . . . . . .124
. . . . . . . . . . . . . . . . . . . . . .124
2 . . . . . . . . . . . . . . . . . . .83
3 . . . . . . . . . . . . . . . . . . .83
4 . . . . . . . . . . . . . . . . . . .83
5 . . . . . . . . . . . . . . . . . . .83
6 . . . . . . . . . . . . . . . . . . .83
. . . . . . . . . . . . . . . . . . . . .81
SL9 . . . . . . . . . . . . . . . . . . . . . .124
SLB1 . . . . . . . . . . . . . . . . . . . . .151
SLB2 . . . . . . . . . . . . . . . . . . . . .151
SLB3 . . . . . . . . . . . . . . . . . . . . .151
SLB4 . . . . . . . . . . . . . . . . . . . . .151
SLB5 . . . . . . . . . . . . . . . . . . . . .151
ST
ST
ST
ST
ST
ST
1 . . . . . . . . . . . . . . . . . . . . . .81
10 . . . . . . . . . . . . . . . . . . . . .81
11 . . . . . . . . . . . . . . . . . . . . .81
12 . . . . . . . . . . . . . . . . . . . . .81
2 . . . . . . . . . . . . . . . . . . . . . .81
3 . . . . . . . . . . . . . . . . . . . . . .81
STG 5 . . . . . . . . . . . . . . . . . . . . .82
STG 6 . . . . . . . . . . . . . . . . . . . . .82
STG 7 . . . . . . . . . . . . . . . . . . . . .82
STG 8 . . . . . . . . . . . . . . . . . . . . .82
STG 9 . . . . . . . . . . . . . . . . . . . . .82
STGK 1 . . . . . . . . . . . . . . . . . . .82
T25 . . . . . . . . . . . . . . . . . . . . . .117
T25 MT . . . . . . . . . . . . . . . . . . .116
T250M . . . . . . . . . . . . . . . . . . .121
T300M . . . . . . . . . . . . . . . . . . .121
T35 . . . . . . . . . . . . . . . . . . . . . .117
T35 MT . . . . . . . . . . . . . . . . . . .116
SLB6 . . . . . . . . . . . . . . . . . . . . .151
SSACB100 . . . . . . . . . . . .140, 143
SSACB38 . . . . . . . . . . . . .140, 143
SSACB50 . . . . . . . . . . . . .140, 143
SSACB75 . . . . . . . . . . . . .140, 143
SSBC100 . . . . . . . . . . . . . . . . . .91
ST
ST
ST
ST
ST
ST
4
5
6
7
8
9
STGK 2
STGK 3
STGK 4
STGK 5
STGK 6
STGN 1
. . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . .82
T350M . . . . . . . . . . . . . . . . . . .121
T400M . . . . . . . . . . . . . . . . . . .121
T45 . . . . . . . . . . . . . . . . . . . . . .117
T45 MT . . . . . . . . . . . . . . . . . . .116
T50M . . . . . . . . . . . . . . . . . . . .121
T55 . . . . . . . . . . . . . . . . . . . . . .117
SSBC50 . . . . . . . . . . . . . . . . . . .91
SSBC75 . . . . . . . . . . . . . . . . . . .91
SSC100 . . . . . . . . . . . . . . . . . . .91
SSC50 . . . . . . . . . . . . . . . . . . . .91
SSC75 . . . . . . . . . . . . . . . . . . . .91
SSR1 . . . . . . . . . . . . . . . . . . . . .99
STA
STA
STA
STA
STA
STA
1 . . . . . . . . . . . . . . . . . . . . .81
10 . . . . . . . . . . . . . . . . . . . .81
11 . . . . . . . . . . . . . . . . . . . .81
12 . . . . . . . . . . . . . . . . . . . .81
2 . . . . . . . . . . . . . . . . . . . . .81
3 . . . . . . . . . . . . . . . . . . . . .81
STGN 2 . . . . . . . . . . . . . . . . . . .82
STGN 3 . . . . . . . . . . . . . . . . . . .82
STGN 4 . . . . . . . . . . . . . . . . . . .82
STGN 5 . . . . . . . . . . . . . . . . . . .82
STGN 6 . . . . . . . . . . . . . . . . . . .82
STM 1 . . . . . . . . . . . . . . . . . . . . .83
T55 MT . . . . . . . . . . . . . . . . . . .116
T65 . . . . . . . . . . . . . . . . . . . . . .117
T65 MT . . . . . . . . . . . . . . . . . . .116
T75 . . . . . . . . . . . . . . . . . . . . . .117
T75M . . . . . . . . . . . . . . . . . . . .121
T85 . . . . . . . . . . . . . . . . . . . . . .117
SSR11
SSR12
SSR13
SSR14
SSR15
SSR16
STA
STA
STA
STA
STA
STA
4
5
6
7
8
9
STM 2 . . . . . . . . . . . . . . . . . . . . .83
STM 3 . . . . . . . . . . . . . . . . . . . . .83
STM 4 . . . . . . . . . . . . . . . . . . . . .83
STM 5 . . . . . . . . . . . . . . . . . . . . .83
STM 6 . . . . . . . . . . . . . . . . . . . . .83
STTB 1 . . . . . . . . . . . . . . . . . . . .82
T95 . . . . . . . . . . . . . . . . . . . . . .117
TB100M . . . . . . . . . . . . . . . . . .121
TB125M . . . . . . . . . . . . . . . . . .121
TB150M . . . . . . . . . . . . . . . . . .121
TB200M . . . . . . . . . . . . . . . . . .121
TB50M . . . . . . . . . . . . . . . . . . .121
TB75M . . . . . . . . . . . . . . . . . . .121
TCC1 . . . . . . . . . . . . . . . . . . . .114
TCC10 . . . . . . . . . . . . . . . . . . . .114
TCC12 . . . . . . . . . . . . . . . . . . . .114
TCC14 . . . . . . . . . . . . . . . . . . . .114
TCC2 . . . . . . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . . . . . .99
. . . . . . . . . . . . . . . . . . . .99
. . . . . . . . . . . . . . . . . . . .99
. . . . . . . . . . . . . . . . . . . .99
. . . . . . . . . . . . . . . . . . . .99
. . . . . . . . . . . . . . . . . . . .99
. . . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . .81
. . . . . . . . . . . . . . . . . . . . .81
SSR2 . . . . . . . . . . . . . . . . . . . . .99
SSR21 . . . . . . . . . . . . . . . . . . . .99
SSR22 . . . . . . . . . . . . . . . . . . . .99
SSR23 . . . . . . . . . . . . . . . . . . . .99
SSR24 . . . . . . . . . . . . . . . . . . . .99
SSR25 . . . . . . . . . . . . . . . . . . . .99
STAC 1 . . . . . . . . . . . . . . . . . . . .82
STAC 1CD . . . . . . . . . . . . . . . . .83
STAC 1ST . . . . . . . . . . . . . . . . . .83
STAC 2 . . . . . . . . . . . . . . . . . . . .82
STAC 3 . . . . . . . . . . . . . . . . . . . .82
STAG 1 . . . . . . . . . . . . . . . . . . . .82
STTB
STTB
STTB
STTB
STTB
STTB
SSR26 . . . . . . . . . . . . . . . . . . . .99
SSR3 . . . . . . . . . . . . . . . . . . . . .99
SSR4 . . . . . . . . . . . . . . . . . . . . .99
SSR5 . . . . . . . . . . . . . . . . . . . . .99
SSR6 . . . . . . . . . . . . . . . . . . . . .99
SSTC 1 . . . . . . . . . . . . . . . . . . . .83
STAG
STAG
STAG
STAG
STAG
STAG
STTB 7 . . . . . . . . . . . . . . . . . . . .82
STTB 8 . . . . . . . . . . . . . . . . . . . .82
STTB 9 . . . . . . . . . . . . . . . . . . . .82
STTBA 1 . . . . . . . . . . . . . . . . . . .83
STTBA 2 . . . . . . . . . . . . . . . . . . .83
STTBA 3 . . . . . . . . . . . . . . . . . . .83
TCC3
TCC4
TCC5
TCC6
TCC7
TCC8
SSTC 1CD . . . . . . . . . . . . . . . . .83
SSTG 1 . . . . . . . . . . . . . . . . . . .81
SSTG 10 . . . . . . . . . . . . . . . . . . .81
SSTG 2 . . . . . . . . . . . . . . . . . . .81
SSTG 3 . . . . . . . . . . . . . . . . . . .81
SSTG 4 . . . . . . . . . . . . . . . . . . .81
STAG 5 . . . . . . . . . . . . . . . . . . . .82
STAG 6 . . . . . . . . . . . . . . . . . . . .82
STAG 7 . . . . . . . . . . . . . . . . . . . .82
STAG 8 . . . . . . . . . . . . . . . . . . . .82
STAG 9 . . . . . . . . . . . . . . . . . . . .82
STAGN 1 . . . . . . . . . . . . . . . . . .82
STTBA 4
STTBA 5
STTBA 6
STTBA 7
STTBA 8
STTTB 1
TCC9 . . . . . . . . . . . . . . . . . . . .114
TP100 . . . . . . . . . . . . . . . . . . . . .11
TP1000 . . . . . . . . . . . . . . . . . . . .52
TP1009 . . . . . . . . . . . . . . . . . . . .52
TP101 . . . . . . . . . . . . . . . . . . . . .11
TP1010 . . . . . . . . . . . . . . . . . . . .52
178
10 . . . . . . . . . . . . . . . . . . .82
11 . . . . . . . . . . . . . . . . . . .82
12 . . . . . . . . . . . . . . . . . . .82
2 . . . . . . . . . . . . . . . . . . . .82
3 . . . . . . . . . . . . . . . . . . . .82
4 . . . . . . . . . . . . . . . . . . . .82
US: 1-866-764-5454
CAN: 1-800-265-0502
10 . . . . . . . . . . . . . . . . . . .82
2 . . . . . . . . . . . . . . . . . . . .82
3 . . . . . . . . . . . . . . . . . . . .82
4 . . . . . . . . . . . . . . . . . . . .82
5 . . . . . . . . . . . . . . . . . . . .82
6 . . . . . . . . . . . . . . . . . . . .82
. . . . . . . . . . . . . . . . . . .83
. . . . . . . . . . . . . . . . . . .83
. . . . . . . . . . . . . . . . . . .83
. . . . . . . . . . . . . . . . . . .83
. . . . . . . . . . . . . . . . . . .83
. . . . . . . . . . . . . . . . . . .83
Copyright© 2007 Cooper Crouse-Hinds
. . . . . . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . . . . . .114
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
TP1013 . . . . . . . . . . . . . . . . . . . .52
TP1014 . . . . . . . . . . . . . . . . . . . .52
TP1020 . . . . . . . . . . . . . . . . . . . .52
TP1023 . . . . . . . . . . . . . . . . . . . .52
TP1024 . . . . . . . . . . . . . . . . . . . .52
TP103 . . . . . . . . . . . . . . . . . . . . .11
TP1690 . . . . . . . . . . . . . . . . . . . .52
TP170 . . . . . . . . . . . . . . . . . . . . .11
TP171 . . . . . . . . . . . . . . . . . . . . .11
TP172 . . . . . . . . . . . . . . . . . . . . .11
TP174 . . . . . . . . . . . . . . . . . . . . .11
TP177 . . . . . . . . . . . . . . . . . . . . .15
TP270
TP272
TP273
TP274
TP275
TP276
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .28
. . . . . . . . . . . . . . . . . . . . .23
TP331
TP332
TP333
TP334
TP335
TP336
TP104 . . . . . . . . . . . . . . . . . . . . .11
TP1040 . . . . . . . . . . . . . . . . . . . .52
TP1045 . . . . . . . . . . . . . . . . . . . .52
TP106 . . . . . . . . . . . . . . . . . . . . .11
TP114 . . . . . . . . . . . . . . . . . . . . .11
TP115 . . . . . . . . . . . . . . . . . . . . .11
TP178 . . . . . . . . . . . . . . . . . . . . .15
TP179 . . . . . . . . . . . . . . . . . . . . .15
TP180 . . . . . . . . . . . . . . . . . . . . .15
TP1800 . . . . . . . . . . . . . . . . . . . .52
TP1802 . . . . . . . . . . . . . . . . . . . .56
TP1832 . . . . . . . . . . . . . . . . . . . .56
TP278
TP280
TP282
TP284
TP286
TP288
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
TP338 . . . . . . . . . . . . . . . . . . . . .23
TP339 . . . . . . . . . . . . . . . . . . . . .23
TP348 . . . . . . . . . . . . . . . . . . . . .48
TP3490 . . . . . . . . . . . . . . . . . . . .52
TP35000 . . . . . . . . . . . . . . . . . . .37
TP354 . . . . . . . . . . . . . . . . . . . . .27
TP116
TP118
TP120
TP123
TP124
TP126
. . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . .11
. . . . . . . . . . . . . . . . . . . . .11
TP184 . . . . . . . . . . . . . . . . . . . . .15
TP185 . . . . . . . . . . . . . . . . . . . . .15
TP188 . . . . . . . . . . . . . . . . . . . . .15
TP190 . . . . . . . . . . . . . . . . . . . . .15
TP1900 . . . . . . . . . . . . . . . . . . . .52
TP1930 . . . . . . . . . . . . . . . . . . . .52
TP290 . . . . . . . . . . . . . . . . . . . . .23
TP292 . . . . . . . . . . . . . . . . . . . . .23
TP294 . . . . . . . . . . . . . . . . . . . . .23
TP298 . . . . . . . . . . . . . . . . . . . . .23
TP300 . . . . . . . . . . . . . . . . . . . . .23
TP30000 . . . . . . . . . . . . . . . . . . .37
TP35403PF . . . . . . . . . . . . . . . .38
TP35404PF . . . . . . . . . . . . . . . .38
TP35414 . . . . . . . . . . . . . . . . . . .38
TP35431 . . . . . . . . . . . . . . . . . . .38
TP35434 . . . . . . . . . . . . . . . . . . .38
TP35454 . . . . . . . . . . . . . . . . . . .38
TP130 . . . . . . . . . . . . . . . . . . . . .11
TP1300 . . . . . . . . . . . . . . . . . . . .28
TP1300 1 . . . . . . . . . . . . . . . . . .28
TP131 . . . . . . . . . . . . . . . . . . . . .11
TP132 . . . . . . . . . . . . . . . . . . . . .11
TP134 . . . . . . . . . . . . . . . . . . . . .11
TP196 . . . . . . . . . . . . . . . . . . . . .15
TP2000 . . . . . . . . . . . . . . . . . . . .52
TP2002 . . . . . . . . . . . . . . . . . . . .56
TP2020 . . . . . . . . . . . . . . . . . . . .52
TP2030 . . . . . . . . . . . . . . . . . . . .52
TP206 . . . . . . . . . . . . . . . . . . . . .15
TP301 . . . . . . . . . . . . . . . . . . . . .28
TP302 . . . . . . . . . . . . . . . . . . . . .23
TP304 . . . . . . . . . . . . . . . . . . . . .23
TP30403PF . . . . . . . . . . . . . . . .38
TP30404PF . . . . . . . . . . . . . . . .38
TP30414 . . . . . . . . . . . . . . . . . . .38
TP356 . . . . . . . . . . . . . . . . . . . . .27
TP3600 . . . . . . . . . . . . . . . . . . . .52
TP36000 . . . . . . . . . . . . . . . . . . .37
TP3602 . . . . . . . . . . . . . . . . . . . .56
TP3630 . . . . . . . . . . . . . . . . . . . .52
TP3632 . . . . . . . . . . . . . . . . . . . .56
TP137 . . . . . . . . . . . . . . . . . . . . .11
TP138 . . . . . . . . . . . . . . . . . . . . .11
TP158 . . . . . . . . . . . . . . . . . . . . .11
TP1600 . . . . . . . . . . . . . . . . . . . .52
TP16002 . . . . . . . . . . . . . . . . . . .57
TP16003 . . . . . . . . . . . . . . . . . . .57
TP210
TP213
TP214
TP216
TP217
TP218
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
TP30431 . . . . . . . . . . . . . . . . . . .38
TP30434 . . . . . . . . . . . . . . . . . . .38
TP30454 . . . . . . . . . . . . . . . . . . .38
TP306 . . . . . . . . . . . . . . . . . . . . .23
TP308 . . . . . . . . . . . . . . . . . . . . .23
TP310 . . . . . . . . . . . . . . . . . . . . .23
TP3635 . . . . . . . . . . . . . . . . . . . .52
TP36403PF . . . . . . . . . . . . . . . .38
TP36404PF . . . . . . . . . . . . . . . .38
TP36414 . . . . . . . . . . . . . . . . . . .38
TP36431 . . . . . . . . . . . . . . . . . . .38
TP36434 . . . . . . . . . . . . . . . . . . .38
TP16007
TP16008
TP16012
TP16013
TP16022
TP16023
. . . . . . . . . . . . . . . . . . .57
. . . . . . . . . . . . . . . . . . .57
. . . . . . . . . . . . . . . . . . .57
. . . . . . . . . . . . . . . . . . .57
. . . . . . . . . . . . . . . . . . .57
. . . . . . . . . . . . . . . . . . .57
TP220 . . . . . . . . . . . . . . . . . . . . .15
TP222 . . . . . . . . . . . . . . . . . . . . .15
TP224 . . . . . . . . . . . . . . . . . . . . .15
TP226 . . . . . . . . . . . . . . . . . . . . .18
TP2300 . . . . . . . . . . . . . . . . . . . .52
TP2302 . . . . . . . . . . . . . . . . . . . .56
TP31000 . . . . . . . . . . . . . . . . . . .37
TP312 . . . . . . . . . . . . . . . . . . . . .23
TP314 . . . . . . . . . . . . . . . . . . . . .23
TP31403PF . . . . . . . . . . . . . . . .38
TP31404PF . . . . . . . . . . . . . . . .38
TP31414 . . . . . . . . . . . . . . . . . . .38
TP36454 . . . . . . . . . . . . . . . . . . .38
TP36467PF . . . . . . . . . . . . . . . .38
TP368 . . . . . . . . . . . . . . . . . . . . .28
TP37000 . . . . . . . . . . . . . . . . . . .37
TP372 . . . . . . . . . . . . . . . . . . . . .28
TP37403PF . . . . . . . . . . . . . . . .38
TP16098 . . . . . . . . . . . . . . . . . . .57
TP16099 . . . . . . . . . . . . . . . . . . .57
TP161 . . . . . . . . . . . . . . . . . . . . .11
TP16107 . . . . . . . . . . . . . . . . . . .57
TP16108 . . . . . . . . . . . . . . . . . . .57
TP16110 . . . . . . . . . . . . . . . . . . .57
TP2332 . . . . . . . . . . . . . . . . . . . .56
TP236 . . . . . . . . . . . . . . . . . . . . .18
TP238 . . . . . . . . . . . . . . . . . . . . .18
TP239 . . . . . . . . . . . . . . . . . . . . .18
TP240 . . . . . . . . . . . . . . . . . . . . .18
TP242 . . . . . . . . . . . . . . . . . . . . .18
TP31431 . . . . . . . . . . . . . . . . . . .38
TP31434 . . . . . . . . . . . . . . . . . . .38
TP31436PF . . . . . . . . . . . . . . . .38
TP31454 . . . . . . . . . . . . . . . . . . .38
TP31467PF . . . . . . . . . . . . . . . .38
TP315 . . . . . . . . . . . . . . . . . . . . .28
TP37404PF . . . . . . . . . . . . . . . .38
TP37414 . . . . . . . . . . . . . . . . . . .38
TP37431 . . . . . . . . . . . . . . . . . . .38
TP37434 . . . . . . . . . . . . . . . . . . .38
TP37454 . . . . . . . . . . . . . . . . . . .38
TP376 . . . . . . . . . . . . . . . . . . . . .28
TP16111 . . . . . . . . . . . . . . . . . . .57
TP16112 . . . . . . . . . . . . . . . . . . .57
TP16113 . . . . . . . . . . . . . . . . . . .57
TP16122 . . . . . . . . . . . . . . . . . . .57
TP16123 . . . . . . . . . . . . . . . . . . .57
TP162 . . . . . . . . . . . . . . . . . . . . .11
TP243
TP244
TP246
TP248
TP249
TP250
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
TP316 . . . . . . . . . . . . . . . . . . . . .23
TP317 . . . . . . . . . . . . . . . . . . . . .23
TP318 . . . . . . . . . . . . . . . . . . . . .23
TP320 . . . . . . . . . . . . . . . . . . . . .23
TP32000 . . . . . . . . . . . . . . . . . . .37
TP322 . . . . . . . . . . . . . . . . . . . . .27
TP377
TP379
TP391
TP393
TP395
TP403
TP16200 . . . . . . . . . . . . . . . . . . .57
TP16201 . . . . . . . . . . . . . . . . . . .57
TP163 . . . . . . . . . . . . . . . . . . . . .11
TP16307 . . . . . . . . . . . . . . . . . . .57
TP16308 . . . . . . . . . . . . . . . . . . .57
TP16310 . . . . . . . . . . . . . . . . . . .57
TP252
TP254
TP256
TP258
TP259
TP260
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
TP323 . . . . . . . . . . . . . . . . . . . . .27
TP32403PF . . . . . . . . . . . . . . . .38
TP32404PF . . . . . . . . . . . . . . . .38
TP32414 . . . . . . . . . . . . . . . . . . .38
TP32431 . . . . . . . . . . . . . . . . . . .38
TP32434 . . . . . . . . . . . . . . . . . . .38
TP403 PF . . . . . . . . . . . . . . . . . .30
TP403SSB . . . . . . . . . . . . . . . . .36
TP404 . . . . . . . . . . . . . . . . . . . . .30
TP404 PF . . . . . . . . . . . . . . . . . .30
TP404SSB . . . . . . . . . . . . . . . . .36
TP405 . . . . . . . . . . . . . . . . . . . . .30
TP16311 . . . . . . . . . . . . . . . . . . .57
TP16317 . . . . . . . . . . . . . . . . . . .57
TP16318 . . . . . . . . . . . . . . . . . . .57
TP164 . . . . . . . . . . . . . . . . . . . . .11
TP16511 . . . . . . . . . . . . . . . .28, 57
TP168 . . . . . . . . . . . . . . . . . . . . .11
TP261
TP262
TP264
TP266
TP267
TP269
. . . . . . . . . . . . . . . . . . . . .28
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .23
TP32454 . . . . . . . . . . . . . . . . . . .38
TP32454PF . . . . . . . . . . . . . . . .38
TP326 . . . . . . . . . . . . . . . . . . . . .27
TP328 . . . . . . . . . . . . . . . . . . . . .27
TP329 . . . . . . . . . . . . . . . . . . . . .27
TP330 . . . . . . . . . . . . . . . . . . . . .27
TP408
TP410
TP412
TP414
TP418
TP422
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .28
. . . . . . . . . . . . . . . . . . . . .28
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .35
179
Catalog
Number
TP423
TP424
TP425
TP426
TP428
TP431
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .35
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .35
. . . . . . . . . . . . . . . . . . . . .35
. . . . . . . . . . . . . . . . . . . . .30
TP507
TP508
TP509
TP510
TP511
TP512
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
TP590
TP591
TP592
TP593
TP594
TP595
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
TP678
TP680
TP682
TP683
TP684
TP685
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
TP431SSB . . . . . . . . . . . . . . . . .36
TP432 . . . . . . . . . . . . . . . . . . . . .30
TP434 . . . . . . . . . . . . . . . . . . . . .30
TP436 . . . . . . . . . . . . . . . . . . . . .30
TP437 . . . . . . . . . . . . . . . . . . . . .30
TP438 . . . . . . . . . . . . . . . . . . . . .30
TP513
TP514
TP515
TP516
TP517
TP518
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
TP596
TP598
TP600
TP602
TP604
TP606
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .47
TP686
TP687
TP690
TP691
TP692
TP693
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
TP440 . . . . . . . . . . . . . . . . . . . . .30
TP444 . . . . . . . . . . . . . . . . . . . . .30
TP444SSB . . . . . . . . . . . . . . . . .36
TP445 . . . . . . . . . . . . . . . . . . . . .30
TP446 . . . . . . . . . . . . . . . . . . . . .30
TP449 . . . . . . . . . . . . . . . . . . . . .30
TP519
TP520
TP522
TP524
TP526
TP528
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
TP608 . . . . . . . . . . . . . . . . . . . . .47
TP610 . . . . . . . . . . . . . . . . . . . . .47
TP6100 . . . . . . . . . . . . . . . . . . . .52
TP6102 . . . . . . . . . . . . . . . . . . . .56
TP612 . . . . . . . . . . . . . . . . . . . . .47
TP613 . . . . . . . . . . . . . . . . . . . . .47
TP694 . . . . . . . . . . . . . . . . . . . . .49
TP695 . . . . . . . . . . . . . . . . . . . . .49
TP700 . . . . . . . . . . . . . . . . . . . . .21
TP701 . . . . . . . . . . . . . . . . . . . . .21
TP7010 . . . . . . . . . . . . . . . . . . . .59
TP7011 . . . . . . . . . . . . . . . . . . . .59
TP450 . . . . . . . . . . . . . . . . . . . . .30
TP450SSB . . . . . . . . . . . . . . . . .36
TP451 . . . . . . . . . . . . . . . . . . . . .30
TP452 . . . . . . . . . . . . . . . . . . . . .30
TP454 . . . . . . . . . . . . . . . . . . . . .30
TP454SSB . . . . . . . . . . . . . . . . .36
TP529
TP530
TP531
TP532
TP534
TP536
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
TP6132 . . . . . . . . . . . . . . . . . . . .56
TP6135 . . . . . . . . . . . . . . . . . . . .52
TP614 . . . . . . . . . . . . . . . . . . . . .47
TP616 . . . . . . . . . . . . . . . . . . . . .47
TP618 . . . . . . . . . . . . . . . . . . . . .47
TP6180 . . . . . . . . . . . . . . . . . . . .52
TP7012 . . . . . . . . . . . . . . . . . . . .59
TP7018 . . . . . . . . . . . . . . . . . . . .59
TP702 . . . . . . . . . . . . . . . . . . . . .21
TP7026 . . . . . . . . . . . . . . . . . . . .59
TP703 . . . . . . . . . . . . . . . . . . . . .21
TP7034 . . . . . . . . . . . . . . . . . . . .59
TP456 . . . . . . . . . . . . . . . . . . . . .30
TP459 . . . . . . . . . . . . . . . . . . . . .30
TP4600 . . . . . . . . . . . . . . . . . . . .52
TP4602 . . . . . . . . . . . . . . . . . . . .56
TP461 . . . . . . . . . . . . . . . . . . . . .30
TP4630 . . . . . . . . . . . . . . . . . . . .52
TP538
TP540
TP541
TP542
TP543
TP548
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .42
TP620
TP622
TP623
TP624
TP628
TP629
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .50
TP704 . . . . . . . . . . . . . . . . . . . . .21
TP7042 . . . . . . . . . . . . . . . . . . . .59
TP705 . . . . . . . . . . . . . . . . . . . . .21
TP7050 . . . . . . . . . . . . . . . . . . . .59
TP7058 . . . . . . . . . . . . . . . . . . . .59
TP706 . . . . . . . . . . . . . . . . . . . . .21
TP4632 . . . . . . . . . . . . . . . . . . . .56
TP4635 . . . . . . . . . . . . . . . . . . . .52
TP467 . . . . . . . . . . . . . . . . . . . . .30
TP469 . . . . . . . . . . . . . . . . . . . . .30
TP472 . . . . . . . . . . . . . . . . . . . . .40
TP473 . . . . . . . . . . . . . . . . . . . . .40
TP549
TP550
TP554
TP556
TP557
TP558
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
TP630
TP631
TP632
TP633
TP635
TP636
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .48
TP7066 . . . . . . . . . . . . . . . . . . . .59
TP707 . . . . . . . . . . . . . . . . . . . . .21
TP7071 . . . . . . . . . . . . . . . . . . . .59
TP7074 . . . . . . . . . . . . . . . . . . . .59
TP7078 . . . . . . . . . . . . . . . . . . . .59
TP708 . . . . . . . . . . . . . . . . . . . . .21
TP474
TP475
TP476
TP477
TP478
TP479
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
TP560 . . . . . . . . . . . . . . . . . . . . .42
TP562 . . . . . . . . . . . . . . . . . . . . .42
TP563 . . . . . . . . . . . . . . . . . . . . .42
TP563SSB . . . . . . . . . . . . . . . . .36
TP564 . . . . . . . . . . . . . . . . . . . . .42
TP568 . . . . . . . . . . . . . . . . . . . . .45
TP640
TP641
TP644
TP647
TP648
TP649
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .48
TP7082 . . . . . . . . . . . . . . . . . . . .59
TP7086 . . . . . . . . . . . . . . . . . . . .59
TP7087 . . . . . . . . . . . . . . . . . . . .59
TP7088 . . . . . . . . . . . . . . . . . . . .59
TP709 . . . . . . . . . . . . . . . . . . . . .21
TP7090 . . . . . . . . . . . . . . . . . . . .59
TP480
TP482
TP483
TP484
TP486
TP488
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
TP569
TP570
TP571
TP572
TP573
TP574
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
TP650
TP651
TP652
TP653
TP655
TP657
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .21
. . . . . . . . . . . . . . . . . . . . .48
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .51
TP7094 . . . . . . . . . . . . . . . . . . . .59
TP7098 . . . . . . . . . . . . . . . . . . . .59
TP710 . . . . . . . . . . . . . . . . . . . . .37
TP7102 . . . . . . . . . . . . . . . . . . . .59
TP7106 . . . . . . . . . . . . . . . . . . . .59
TP7110 . . . . . . . . . . . . . . . . . . . .59
TP489
TP490
TP494
TP496
TP498
TP499
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
TP575
TP576
TP578
TP579
TP580
TP582
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
TP659
TP660
TP661
TP662
TP664
TP667
. . . . . . . . . . . . . . . . . . . . .21
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .51
TP7114
TP7118
TP7120
TP7122
TP7123
TP7126
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
TP500
TP501
TP502
TP503
TP504
TP506
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .40
TP583
TP584
TP586
TP587
TP588
TP589
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .47
. . . . . . . . . . . . . . . . . . . . .45
TP668
TP670
TP672
TP674
TP676
TP677
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .15
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
. . . . . . . . . . . . . . . . . . . . .18
TP7130
TP7134
TP7137
TP7138
TP7142
TP7143
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
180
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
TP7144
TP7146
TP7147
TP7148
TP7149
TP7150
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
TP7298 . . . . . . . . . . . . . . . . . . . .62
TP730 . . . . . . . . . . . . . . . . . . . . .45
TP7300 . . . . . . . . . . . . . . . . . . . .62
TP7301 . . . . . . . . . . . . . . . . . . . .62
TP7302 . . . . . . . . . . . . . . . . . . . .62
TP7308 . . . . . . . . . . . . . . . . . . . .62
TP7620
TP7621
TP7630
TP7640
TP7650
TP7660
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
TP872
TP873
TP874
TP876
TP877
TP900
TP7151
TP7152
TP7158
TP7159
TP7160
TP7162
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . .59, 62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .66
TP7309
TP7310
TP7312
TP7313
TP7314
TP7316
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
TP7670
TP7680
TP7800
TP7801
TP7805
TP7810
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . .72, 76
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . .72, 76
TP901 . . . . . . . . . . . . . . . . . . . . .21
TP902 . . . . . . . . . . . . . . . . . . . . .21
TPFSS . . . . . . . . . . . . . . . . . . . .56
TPRFH12 . . . . . . . . . . . . . . .74, 88
TPSFH12 . . . . . . . . . . . . . . .74, 88
UBM100HD . . . . . . . . . . . . . . . .114
TP7163
TP7164
TP7165
TP7166
TP7170
TP7173
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .59
TP7317 . . . . . . . . . . . . . . . . . . . .62
TP7318 . . . . . . . . . . . . . . . . . . . .62
TP732 . . . . . . . . . . . . . . . . . . . . .45
TP7320 . . . . . . . . . . . . . . . . . . . .62
TP7321 . . . . . . . . . . . . . . . . . . . .62
TP7322 . . . . . . . . . . . . . . . . . . . .62
TP7811
TP7815
TP7820
TP7825
TP7830
TP7835
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . .72, 76
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . .72, 76
. . . . . . . . . . . . . . . . . . . .72
UBM125HD
UBM150HD
UBM200HD
UBM250HD
UBM300HD
UBM350HD
TP7174
TP7176
TP7178
TP7186
TP7188
TP7199
. . . . . . . . . . . . . . . . . . . .59
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .66
. . . . . . . . . . . . . . . . . . . .62
TP7330 . . . . . . . . . . . . . . . . . . . .66
TP7331 . . . . . . . . . . . . . . . . . . . .66
TP7332 . . . . . . . . . . . . . . . . . . . .66
TP734 . . . . . . . . . . . . . . . . . . . . .45
TP736 . . . . . . . . . . . . . . . . . . . . .45
TP738 . . . . . . . . . . . . . . . . . . . . .45
TP7840
TP7860
TP7870
TP7920
TP7924
TP7925
. . . . . . . . . . . . . . . . .72, 76
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .75
. . . . . . . . . . . . . . . . . . . .75
. . . . . . . . . . . . . . . . . . . .75
UBM400HD . . . . . . . . . . . . . . . .114
UBM50HD . . . . . . . . . . . . . . . . .114
UBM75HD . . . . . . . . . . . . . . . . .114
WAB040402 . . . . . . . . . . . . . . .159
WAB040403 . . . . . . . . . . . . . . .159
WAB040404 . . . . . . . . . . . . . . .159
TP720 . . . . . . . . . . . . . . . . . . . . .45
TP7202 . . . . . . . . . . . . . . . . . . . .62
TP7206 . . . . . . . . . . . . . . . . . . . .62
TP7207 . . . . . . . . . . . . . . . . . . . .62
TP7208 . . . . . . . . . . . . . . . . . . . .62
TP7209 . . . . . . . . . . . . . . . . . . . .62
TP741 . . . . . . . . . . . . . . . . . . . . .45
TP7440 . . . . . . . . . . . . . . . . . . . .72
TP7441 . . . . . . . . . . . . . . . . . . . .72
TP7442 . . . . . . . . . . . . . . . . . . . .72
TP7443 . . . . . . . . . . . . . . . . . . . .72
TP7445 . . . . . . . . . . . . . . . . . . . .72
TP7927 . . . . . . . . . . . . . . . . . . . .75
TP7928 . . . . . . . . . . . . . . . . . . . .75
TP7940 . . . . . . . . . . . . . . . . .62, 75
TP7942 . . . . . . . . . . . . . . . . .62, 75
TP7944 . . . . . . . . . . . . . . . . .62, 75
TP802 . . . . . . . . . . . . . . . . . . . . .51
WAB050503
WAB050504
WAB060403
WAB060404
WAB060603
WAB060604
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
TP7214 . . . . . . . . . . . . . . . . . . . .62
TP7218 . . . . . . . . . . . . . . . . . . . .62
TP722 . . . . . . . . . . . . . . . . . . . . .45
TP7220 . . . . . . . . . . . . . . . . . . . .62
TP7224 . . . . . . . . . . . . . . . . . . . .62
TP7228 . . . . . . . . . . . . . . . . . . . .62
TP7446
TP7447
TP7448
TP7450
TP7451
TP7460
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
TP803
TP804
TP805
TP806
TP820
TP821
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .51
. . . . . . . . . . . . . . . . . . . . .49
. . . . . . . . . . . . . . . . . . . . .49
WAB060606
WAB080403
WAB080604
WAB080606
WAB080804
WAB080806
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
TP7232 . . . . . . . . . . . . . . . . . . . .62
TP7233 . . . . . . . . . . . . . . . . . . . .62
TP7236 . . . . . . . . . . . . . . . . . . . .62
TP7237 . . . . . . . . . . . . . . . . . . . .62
TP7238 . . . . . . . . . . . . . . . . . . . .62
TP724 . . . . . . . . . . . . . . . . . . . . .45
TP7462
TP7463
TP7464
TP7466
TP7468
TP7469
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
TP830
TP831
TP832
TP833
TP834
TP835
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .35
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .42
WAB080808
WAB090604
WAB100604
WAB100804
WAB100806
WAB101006
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
TP7240
TP7241
TP7242
TP7244
TP7248
TP7252
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
TP7470
TP7471
TP7472
TP7474
TP7475
TP7476
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
TP836
TP837
TP838
TP839
TP840
TP841
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .23
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .30
. . . . . . . . . . . . . . . . . . . . .35
WAB120604
WAB120606
WAB120806
WAB120808
WAB121204
WAB121206
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
TP726 . . . . . . . . . . . . . . . . . . . . .45
TP7260 . . . . . . . . . . . . . . . . . . . .62
TP7268 . . . . . . . . . . . . . . . . . . . .62
TP7272 . . . . . . . . . . . . . . . . . . . .62
TP7276 . . . . . . . . . . . . . . . . . . . .62
TP728 . . . . . . . . . . . . . . . . . . . . .45
TP7477
TP7478
TP7490
TP7495
TP7496
TP7497
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
TP842
TP850
TP851
TP852
TP853
TP854
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .40
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .45
. . . . . . . . . . . . . . . . . . . . .27
. . . . . . . . . . . . . . . . . . . . .40
WAB121208
WAB160606
WAB161208
WAB181206
WAB181208
WAB181210
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
TP7280
TP7292
TP7293
TP7294
TP7296
TP7297
TP7498
TP7499
TP7600
TP7601
TP7610
TP7611
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
. . . . . . . . . . . . . . . . . . . .72
TP860
TP861
TP862
TP863
TP870
TP871
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .42
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
WAB181806
WAB181812
WAB241212
WAB242408
WCB040402
WCB040403
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .159
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
. . . . . . . . . . . . . . . . . . . .62
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .50
. . . . . . . . . . . . . . . . . . . . .21
. . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . .114
. . . . . . . . . . . . . . . .114
181
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
WCB040404
WCB050503
WCB050504
WCB060403
WCB060404
WCB060603
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
WJB080604
WJB080606
WJB080804
WJB080806
WJB080808
WJB100806
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF120606
WJBF120806
WJBF120808
WJBF120810
WJBF121206
WJBF121208
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLFLSF 3 . . . . . . . . . . . . . . . . .70
WLFLSF 4 . . . . . . . . . . . . . . . . .70
WLFLWG 3 . . . . . . . . . . . . . . . . .70
WLFLWG 4 . . . . . . . . . . . . . . . . .70
WLPG100HPS/MT . . . . . . . . . . .67
WLPG100HPS/TT . . . . . . . . . . .67
WCB060604
WCB060606
WCB080403
WCB080604
WCB080606
WCB080804
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
WJB100808
WJB101006
WJB101008
WJB120606
WJB120806
WJB120808
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF121212
WJBF121218
WJBF140806
WJBF141410
WJBF161206
WJBF161208
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLPG100MH/MT . . . . . . . . . . . .67
WLPG100MH/TT . . . . . . . . . . . .67
WLPG150HPS/MT . . . . . . . . . . .67
WLPG150HPS/TT . . . . . . . . . . .67
WLPG175MH/MT . . . . . . . . . . . .67
WLPG175MH/TT . . . . . . . . . . . .67
WCB080806
WCB080808
WCB090604
WCB100604
WCB100804
WCB100806
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
WJB120810
WJB121206
WJB121208
WJB121212
WJB121218
WJB140806
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF161606
WJBF180806
WJBF180808
WJBF181006
WJBF181206
WJBF181208
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLPG70HPS/MT . . . . . . . . . . . .67
WLPG70HPS/TT . . . . . . . . . . . .67
WLPG70MH/MT . . . . . . . . . . . . .67
WLPG70MH/TT . . . . . . . . . . . . .67
WLWP100HPS/MT . . . . . . . . . . .67
WLWP100HPS/TT . . . . . . . . . . .67
WCB101006
WCB120604
WCB120606
WCB120806
WCB120808
WCB121204
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
WJB141410
WJB161206
WJB161208
WJB161606
WJB180806
WJB180808
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF181210
WJBF181212
WJBF181218
WJBF181806
WJBF181808
WJBF181812
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLWP100MH/MT . . . . . . . . . . . .67
WLWP100MH/TT . . . . . . . . . . . .67
WLWP150HPS/MT . . . . . . . . . . .67
WLWP150HPS/TT . . . . . . . . . . .67
WLWP175MH/MT . . . . . . . . . . . .67
WLWP175MH/TT . . . . . . . . . . . .67
WCB121206
WCB121208
WCB160606
WCB161208
WCB181206
WCB181208
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
WJB181006
WJB181206
WJB181208
WJB181210
WJB181212
WJB181218
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF181818
WJBF241208
WJBF241212
WJBF241808
WJBF241810
WJBF241812
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLWP250HPS/MT . . . . . . . . . . .67
WLWP250HPS/TT . . . . . . . . . . .67
WLWP250MH/MT . . . . . . . . . . . .67
WLWP250MH/MT S828 . . . . . . .67
WLWP250MH/TT . . . . . . . . . . . .67
WLWP400HPS/MT . . . . . . . . . . .67
WCB181210
WCB181806
WCB181812
WCB241212
WCB242408
WEB040403
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .160
. . . . . . . . . . . . . . .163
WJB181806
WJB181808
WJB181812
WJB181818
WJB241208
WJB241212
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF241818
WJBF242412
WJBF242418
WJBF242424
WJBF302412
WJBF302418
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLWP400HPS/TT . . . . . . . . . . .67
WLWP400MH/MT . . . . . . . . . . . .67
WLWP400MH/MT S828 . . . . . . .67
WLWP400MH/TT . . . . . . . . . . . .67
WLWPMP 1 . . . . . . . . . . . . . . . .70
WLWPWG 1 . . . . . . . . . . . . . . . .70
WEB040404
WEB060604
WEB060606
WEB080804
WEB080806
WEB121206
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
WJB241808
WJB241810
WJB241812
WJB241818
WJB242412
WJB242418
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF362418 . . . . . . . . . . . . . .162
WJBF362424 . . . . . . . . . . . . . .162
WLFL1000HPS/MT . . . . . . . . . .67
WLFL1000HPS/TT . . . . . . . . . . .67
WLFL1000MH/MT . . . . . . . . . . .67
WLFL1000MH/TT . . . . . . . . . . . .67
WLWPWG 2 . . . . . . . . . . . . . . . .70
WLWPWG 3 . . . . . . . . . . . . . . . .70
WMG100 . . . . . . . . . . . . . . . . .131
WMG125 . . . . . . . . . . . . . . . . .131
WMG150 . . . . . . . . . . . . . . . . .131
WMG200 . . . . . . . . . . . . . . . . .131
WEB160606
WEB160806
WEB180808
WEB240606
WEB240808
WEB241010
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
WJB242424 . . . . . . . . . . . . . . .161
WJB302412 . . . . . . . . . . . . . . .161
WJB302418 . . . . . . . . . . . . . . .161
WJB362418 . . . . . . . . . . . . . . .161
WJB362424 . . . . . . . . . . . . . . .161
WJBF040404 . . . . . . . . . . . . . .162
WLFL150HPS/MT . . . . . . . . . . .67
WLFL150HPS/TT . . . . . . . . . . . .67
WLFL175MH/MT . . . . . . . . . . . .67
WLFL175MH/TT . . . . . . . . . . . . .67
WLFL250HPS/MT . . . . . . . . . . .67
WLFL250HPS/TT . . . . . . . . . . . .67
WMG38 . . . . . . . . . . . . . . . . . .131
WMG50 . . . . . . . . . . . . . . . . . .131
WMG75 . . . . . . . . . . . . . . . . . .131
X100M . . . . . . . . . . . . . . . . . . .121
X125M . . . . . . . . . . . . . . . . . . .121
X150M . . . . . . . . . . . . . . . . . . .121
WEB241210
WEB241212
WEB241812
WEB361212
WEB361812
WEB362412
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .163
WJBF060404
WJBF060604
WJBF060606
WJBF080604
WJBF080606
WJBF080804
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLFL250MH/MT . . . . . . . . . . . .67
WLFL250MH/MT S828 . . . . . . .67
WLFL250MH/TT . . . . . . . . . . . . .67
WLFL400HPS/MT . . . . . . . . . . .67
WLFL400HPS/TT . . . . . . . . . . . .67
WLFL400MH/MT . . . . . . . . . . . .67
X200M . . . . . . . . . . . . . . . . . . .121
X50M . . . . . . . . . . . . . . . . . . . .121
X75M . . . . . . . . . . . . . . . . . . . .121
XD010 . . . . . . . . . . . . . . . . . . . .167
XD012 . . . . . . . . . . . . . . . . . . . .167
XD014 . . . . . . . . . . . . . . . . . . . .167
WEB363612
WJB040403
WJB040404
WJB060404
WJB060604
WJB060606
. . . . . . . . . . . . . . .163
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
. . . . . . . . . . . . . . .161
WJBF080806
WJBF080808
WJBF100806
WJBF100808
WJBF101006
WJBF101008
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
. . . . . . . . . . . . . .162
WLFL400MH/MT S828 . . . . . . .67
WLFL400MH/TT . . . . . . . . . . . . .67
WLFLGS 2 . . . . . . . . . . . . . . . . .70
WLFLGS 3 . . . . . . . . . . . . . . . . .70
WLFLGS 4 . . . . . . . . . . . . . . . . .70
WLFLSB 3 . . . . . . . . . . . . . . . . .70
XD3
XD4
XD5
XD6
XD7
XD8
182
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
. . . . . . . . . . . . . . . . . . . . .167
. . . . . . . . . . . . . . . . . . . . .167
. . . . . . . . . . . . . . . . . . . . .167
. . . . . . . . . . . . . . . . . . . . .167
. . . . . . . . . . . . . . . . . . . . .167
. . . . . . . . . . . . . . . . . . . . .167
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
Catalog
Number
Page
XD9 . . . . . . . . . . . . . . . . . . . . .167
XJ128 . . . . . . . . . . . . . . . . . . . .168
XJ148 . . . . . . . . . . . . . . . . . . . .168
XJG104 . . . . . . . . . . . . . . . . . . .168
XJG104 EMT . . . . . . . . . . . . . .169
XJG108 . . . . . . . . . . . . . . . . . . .168
XJG14 . . . . . . . . . . . . . . . . . . . .168
XJG14 EMT . . . . . . . . . . . . . . .169
XJG18 . . . . . . . . . . . . . . . . . . . .168
XJG24 . . . . . . . . . . . . . . . . . . .168
XJG24 EMT . . . . . . . . . . . . . . .169
XJG28 . . . . . . . . . . . . . . . . . . .168
XJG34
XJG34
XJG38
XJG44
XJG44
XJG48
. . . . . . . . . . . . . . . . . . .168
EMT . . . . . . . . . . . . . . .169
. . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . . . .168
EMT . . . . . . . . . . . . . . .169
. . . . . . . . . . . . . . . . . . .168
XJG54
XJG54
XJG58
XJG64
XJG64
XJG68
. . . . . . . . . . . . . . . . . . .168
EMT . . . . . . . . . . . . . . .169
. . . . . . . . . . . . . . . . . . .168
. . . . . . . . . . . . . . . . . . .168
EMT . . . . . . . . . . . . . . .169
. . . . . . . . . . . . . . . . . . .168
XJG74 . . . . . . . . . . . . . . . . . . . .168
XJG74 EMT . . . . . . . . . . . . . . .169
XJG78 . . . . . . . . . . . . . . . . . . .168
XJG84 . . . . . . . . . . . . . . . . . . .168
XJG84 EMT . . . . . . . . . . . . . . .169
XJG88 . . . . . . . . . . . . . . . . . . .168
XJG94 . . . . . . . . . . . . . . . . . . .168
XJG94 EMT . . . . . . . . . . . . . . .169
XJG98 . . . . . . . . . . . . . . . . . . .168
XJGD104 . . . . . . . . . . . . . . . . .170
XJGD34 . . . . . . . . . . . . . . . . . .170
XJGD44 . . . . . . . . . . . . . . . . . .170
XJGD54
XJGD64
XJGD74
XJGD84
XJGD94
. . . . . . . . . . . . . . . . . .170
. . . . . . . . . . . . . . . . . .170
. . . . . . . . . . . . . . . . . .170
. . . . . . . . . . . . . . . . . .170
. . . . . . . . . . . . . . . . . .170
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2007 Cooper Crouse-Hinds
183
2007 Commercial Products Catalog
Distributed by:
For more information:
If further assistance is required, please contact an authorized Cooper
Crouse-Hinds Distributor, Sales Office or Customer Service Department:
In the U.S.:
In Australia:
Cooper Crouse-Hinds
P.O. Box 4999
Syracuse, NY 13221
Toll Free: 866-764-5454
(315) 477-5531
FAX ORDERS ONLY: 1-866-653-0640
FAX: (315) 477-5179
crouse.customerctr@crouse-hinds.com
Cooper Electrical Australia
61-29-743-7000
FAX: 61-29-743-7069
sales@cooperelectrical.com.au
In Canada:
Cooper Crouse-Hinds Canada
Toll Free: 800-265-0502
(905) 507-4187
FAX ORDERS ONLY: 1-866-653-0645
FAX: (905) 568-7048
In Asia (Singapore):
Cooper Crouse-Hinds Pte. Ltd.
65-6297-4849
FAX: 65-6297-4819
sales@cchspore.com.sg
In Middle East (Dubai):
CEAG Middle East LLC
971-4-324-1519
FAX: 971-4-324-1640
In Mexico:
In India:
Cooper Crouse-Hinds, S.A. de C.V.
52-555-804-4000
FAX: 52-555-804-4020
Cooper Crouse-Hinds India
91-22-5604-5150
FAX: 91-22-2404-1811
In Latin America/Caribbean:
For the latest in new products and
services, visit our website at:
Cooper Crouse-Hinds
(954) 764-3853
FAX: (954) 764-3854
www.crouse-hinds.com
In Europe (Germany):
Cooper Crouse-Hinds GmbH
49-6271-806500
FAX: 49-6271-806476
4733-0107
Crouse-Hinds is a registered trademark of Cooper Industries, Inc.
© 2007 Cooper Industries, Inc.
back cover
Printed in U.S.A.
spine
front cover
Download