ENGINEER STAMP: SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL LEGEND SYMBOL REFERENCE AND LINE SYMBOLS XX X-XXX ? X XX-XX WP DETAIL INDICATOR: XX INDICATES DETAIL NUMBER, X-XXX INDICATES DRAWING SHEET WHERE DETAIL IS SHOWN. DESCRIPTION SYMBOL LEGEND SYMBOL RECEPTACLE, DUPLEX WITH GROUND FAULT CIRCUIT INTERRUPTER, WEATHERPROOF: NEMA 5-20R. SYMBOL DESCRIPTION STRUCTURED CABLING XX C/B DIGITAL MULTIMETER (ONE-LINE DIAGRAM). SERVICE ENTRANCE SURGE PROTECTION (ONE-LINE DIAGRAM). RECEPTACLE, QUADRAPLEX: NEMA 5-20R. KEYNOTE INDICATOR. REVISION INDICATOR. RECEPTACLE, SPECIAL PURPOSE. PROVIDE RECEPTACLE TO MATCH EQUIPMENT PLUG. EQUIPMENT INDICATOR. SWITCH, SINGLE POLE ("x" INDICATES FIXTURES CONTROLLED). BREAK, ROUND. 2 SWITCH, DOUBLE POLE ("x" INDICATES FIXTURES CONTROLLED). 3 SWITCH, THREE-WAY ("x" INDICATES FIXTURES CONTROLLED). SOLID STATE REDUCED VOLTAGE MOTOR STARTER. GENERATOR, POWER (ONE-LINE DIAGRAM). X METER. XX VARIABLE FREQUENCY DRIVE (ONE-LINE DIAGRAM). DISCONNECT SWITCH, FUSED. STARTER (ONE-LINE DIAGRAM). W TELEPHONE, WALL MOUNTED: WALL PHONE. X OUTLET, DATA COMMUNICATION ("X" INDICATES QUANTITY OF CABLES). X OUTLET, BUILDING STANDARD COMBINATION TELEPHONE/ DATA COMMUNICATION. SYMBOL C/B WI-FI. CIRCUIT BREAKER, MOLDED CASE (ONE-LINE DIAGRAM). PANELBOARD CABINET, SURFACE MOUNTED, 1 SECTION. C/B ELECTRICAL POWER AND DISTRIBUTION CIRCUIT BREAKER, MOLDED CASE WITH SHUNT TRIP CONT? (ONE-LINE DIAGRAM). FUSE WITH RATING (ONE-LINE DIAGRAM). J JUNCTION BOX. X PULL BOX. FUSE EARTH GROUND (ONE-LINE DIAGRAM). DISC DISC DESCRIPTION PANELBOARD CABINET, FLUSH MOUNTED. SWITCH, ESD (EMERGENCY STOP DEVICE). CONDUCTOR & CONDUIT ("CC") SCHEDULE INDICATOR. REFER TO ONE-LINE DIAGRAM. MISCELLANEOUS SYMBOL LEGEND DISCONNECT SWITCH, NONFUSED. CONT? WIRING METHODS X OVERLOAD RELAY (ONE-LINE DIAGRAM). SWITCH, KEY OPERATED. K LIGHTING (REFER TO FIXTURE SCHEDULE FOR SYMBOLS) (W-3) FIXTURE IDENTIFICATION: (W-3) INDICATES FIXTURE TYPE AS SCHEDULED. C/B CIRCUIT BREAKER, MOTOR CIRCUIT PROTECTION (ONE-LINE CONT? DIAGRAM). DISCONNECT, FUSED (ONE-LINE DIAGRAM). (W-3) C/B DISCONNECT, NONFUSED (ONE-LINE DIAGRAM). CONT? CIRCUIT BREAKER, SOLID STATE (ONE-LINE DIAGRAM). FIXTURE IDENTIFICATION, EMERGENCY WITH BATTERY PACK, CONNECTED TO GENERATOR AS INDICATED: (W-3) INDICATES FIXTURE TYPE AS SCHEDULED. GROUND CONNECTION. CONDUIT SEAL OFF (ONE LINE DIAGRAM). C/B C/B WIRING DEVICES CIRCUIT BREAKER, SOLID STATE WITH GROUND FAULT CONT? PROTECTION (ONE-LINE DIAGRAM). GFP CONT? RECEPTACLE, SINGLE: NEMA 5-20R. MOTOR. X RECEPTACLE, SINGLE: NEMA 10-30R. G GREEN LIGHT. R RED STROBE. LIGHTING CONTROL P MOTOR CIRCUIT PROTECTOR (MCP) COMBINATION MOTOR STARTER. RECEPTACLE, DUPLEX: NEMA 5-20R. X DESCRIPTION SYMBOL LEGEND CONT? RECEPTACLE, QUADRAPLEX, CONNECTED TO UPS: NEMA 5-20R. CONDUIT STUB. DIMENSION RECORD DRAWINGS AND MARK. SYMBOL RECEPTACLE, DUPLEX, CONNECTED TO UPS: NEMA 5-20R. BREAK, STRAIGHT: TO BREAK PARTS OF DRAWING. X-X DESCRIPTION SYMBOL LEGEND EXHAUST FAN OUTLET. HEATER, ELECTRIC RESISTANCE. PHOTOCELL SENSOR, DIRECTIONAL. WALL MOUNTED LED LIGHT FIXTURE CLASS I DIV 2,CLASS I ZONE 2, CLASS II DIV 1 CLASS II DIV 2, CLASS III. SURFACE MOUNTED LED LIGHT FIXTURE CLASS I DIV 2,CLASS I ZONE 2, CLASS II DIV 1 CLASS II DIV 2, CLASS III. TRANSFORMER (ONE-LINE DIAGRAM). A AMBER STROBE. Y YELLOW BEACON. M SIERRA MONITOR METHANE SENSOR. REVISIONS: REV NO. DESCRIPTION REV DATE SPECIALITY EQUIPMENT TRANSFORMER, CURRENT (ONE-LINE DIAGRAM). DELTA CONNECTION (ONE-LINE DIAGRAM). PURGE BLOWER. WYE CONNECTION (ONE-LINE DIAGRAM). CCT CAMERA. XXX A/3 PANELBOARD WITH MAIN CIRCUIT BREAKER. SIZE AND PHASE AS SHOWN (ONE-LINE DIAGRAM). CONNECTION TO THE GROUND CIRCUIT CONDUCTOR (NEUTRAL). ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: SYMBOLS AND LEGENDS SHEET: E-0 ENGINEER STAMP: SITE COORDINATION THE LOCATION, CAPACITY, AND VOLTAGE OF THE LINES ARE ALL IN ACCORDANCE WITH DATA GIVEN THIS OFFICE BY THE UTILITY COMPANY. ACCORDANCE WITH DATA GIVEN THIS OFFICE BY THE UTILITY COMPANY. ACCORDANCE WITH DATA GIVEN THIS OFFICE BY THE UTILITY COMPANY. COORDINATE WITH THE LOCAL UTILITY COMPANY THE INSTALLATION OF THE ELECTRICAL SERVICE. COMPLY WITH UTILITY REGULATIONS. REPORT DISCREPANCIES TO THE ENGINEER. ELECTRIC UTILITY - PERSON CONTACTED: DATE: PHONE NUMBER: - CODES 1. NATIONAL ELECTRICAL CODE 2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA). A. NFPA 52, 2010 EDITION : COMPRESSED NATURAL GAS (CNG) VEHICULAR FUEL SYSTEMS CODE. B. NFPA 70, 2011 EDITION: NATIONAL ELECTRIC CODE AMENDMENTS, AS APPLICABLE. C. NFPA 30A, 2012 EDITION: CODE FOR MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES. D. NFPA 496: STANDARD FOR PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT. 3. INTERNATIONAL BUILDING CODE W/ LOCAL AMENDMENTS. 4. INTERNATIONAL FIRE CODE, WITH LOCAL AMENDMENTS. A. IFC 2208.7 5. OCCUPATIONAL SAFETY AND HEALTH ACT (WORK AREA SOUND-LEVEL LIMITS). 6. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). 7. NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NEMA 250 ENCLOSURES FOR ELECTRICAL EQUIPMENT (1000 VOLTS MAXIMUM). DEFINITIONS NOTE: ALL DEFINITIONS MAY NOT BE USED. INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN", "NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE REFERENCE, NO LIMITATION ON LOCATION IS INTENDED. DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE ENGINEER", AND SIMILAR PHRASES. APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY CONDITIONS. FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS." PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-SUBCONTRACTOR, FOR PERFORMANCE OF A PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY ARE ENGAGED TO PERFORM. TECHNOLOGY SYSTEMS: THE TERM "TECHNOLOGY SYSTEMS" IS USED TO DESCRIBE ALL LOW VOLTAGE SYSTEMS GENERALLY REFERRED TO AS "SPECIAL SYSTEMS". THESE SYSTEMS INCLUDE BUT ARE NOT NECESSARILY LIMITED TO ALL SYSTEMS WHICH UTILIZE VOLTAGES OF LESS THAN 71 VOLTS SUCH AS SOUND SYSTEMS, VIDEO SYSTEMS, TV SYSTEMS, SECURITY SYSTEMS, VOICE AND DATA CABLING SYSTEMS, ETC... ABBREVIATIONS NOTE: ALL ABBREVIATIONS MAY NOT BE USED. 1P 1PH 1WAY 2/C 2WAY 3/C 3PH 3WAY 4OUT SINGLE POLE SINGLE-PHASE ONE-WAY TWO-CONDUCTOR TWO-WAY THREE-CONDUCTOR THREE-PHASE THREE-WAY QUADRUPLE RECEPTACLE OUTLET 4PDT FOUR-POLE DOUBLE THROW 4PST FOUR-POLE SINGLE THROW 4W FOUR-WIRE 4WAY FOUR-WAY A ABOVE COUNTER AC ARMORED CABLE ADA AMERICANS WITH DISABILITIES ACT ADJ ADJACENT AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AIC AMPERE INTERRUPTING CAPACITY ALUM ALUMINUM AMP AMPERE ANN ANNUNCIATOR AP ACCESS POINT (WIRELESS DATA) AR AS REQUIRED ASC AMPS SHORT CIRCUIT ATS AUTOMATIC TRANSFER SWITCH AV AUDIO VISUAL AWG AMERICAN WIRE GAGE BB XFMR BUCK-BOOST TRANSFORMER C CEILING MOUNTED CATV COMMUNITY ANTENNA TELEVISION CB CIRCUIT BREAKER CCBA CUSTOM COLOR AS SELECTED BY ARCHITECT CCTV CLOSED CIRCUIT TELEVISION CFBA CUSTOM FINISH AS SELECTED BY ARCHITECT CF/CI CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CF/OI CONTRACTOR FURNISHED/ OWNER INSTALLED CKT CIRCUIT CM CONSTRUCTION MANAGER CND CONDUIT CO CONVENIENCE OUTLET COR CONTRACTING OFFICER'S REPRESENTATIVE CP CONTROL PANEL CT CURRENT TRANSFORMER CTV CABLE TELEVISION CU COPPER dBA UNIT OF SOUND LEVEL DPDT DOUBLE POLE DOUBLE THROW DS DISCONNECT SWITCH EA EACH EM EMERGENCY EMT ELECTRICAL METALLIC TUBING ENT ELECTRICAL NONMETALLIC TUBING EPO EMERGENCY POWER OFF EQUIP EQUIPMENT EXIST EXISTING F FURNITURE MOUNTED FA FIRE ALARM FCP FIRE ALARM CONTROL PANEL FLA FULL LOAD AMPS FMC FLEXIBLE METAL CONDUIT FOB FREIGHT ON BOARD FVNR FULL VOLTAGE NON-REVERSING FVR FULL VOLTAGE REVERSING G GROUND GEN GENERATOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GFP GROUND FAULT PROTECTION HD HEAVY DUTY HID HIGH INTENSITY DISCHARGE HOA HAND-OFF-AUTOMATIC HP HORSE POWER HPF HIGH POWER FACTOR HPS HIGH PRESSURE SODIUM HV HIGH VOLTAGE HZ HERTZ IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT IN/IS INSULATED/ISOLATED I/O INPUT/OUTPUT IR INFRARED J-BOX JUNCTION BOX KV KILOVOLT KVA kVAR kW kWh LED LFMC LFNC LPS LRA LTG LV MATV MAX MC MCA MCB MCC MCP MDP MG MH MIN MLO MOCP NA NC NEC NEMA NFC NFPA NIC NL NO NTS OC OCP OF/CI OF/OI OFP OH DR OL PB PF PH PNL PT PTZ QTY R RCP RMC RNC RPM RR RVNR SCA SCBA SF SFBA SPDT SPEC SPST S/S ST SWBD SWGR TL TP TP TTB TV TVSS TYP UF UGND UPS V VA VFC W/ W/O WP XFMR KILOVOLT AMPERE KILOVOLT AMPERE REACTIVE KILOWATT KILOWATT HOUR LIGHT EMITTING DIODE LIQUID TIGHT FLEXIBLE METAL CONDUIT CONDUIT LIQUID TIGHT FLEXIBLE NONMETALLIC CONDUIT LOW PRESSURE SODIUM LOCKED ROTOR AMPS LIGHTING LOW VOLTAGE MASTER ANTENNA TELEVISION SYSTEM MAXIMUM METAL CLAD MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MOTOR CIRCUIT PROTECTION MAIN DISTRIBUTION PANEL MOTOR GENERATOR MANHOLE MINIMUM MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NATIONAL FIRE CODE NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NOT TO SCALE ON CENTER OVER CURRENT PROTECTION OWNER FURNISHED/ CONTRACTOR INSTALLED OWNER FURNISHED/ OWNER INSTALLED OBTAIN FROM PLANS OVERHEAD (COILING) DOOR OVERLOAD PUSHBUTTON POWER FACTOR PHASE PANEL POTENTIAL TRANSFORMER PAN/TILT/ZOOM QUANTITY REMOVE REFLECTED CEILING PLAN RIGID METAL CONDUIT RIGID NONMETALLIC CONDUIT REVOLUTIONS PER MINUTE REMOVE AND RELOCATE REDUCED VOLTAGE NON REVERSING SHORT CIRCUIT AMPS STANDARD COLOR AS SELECTED BY ARCHITECT SQUARE FOOT (FEET) SFBA STANDARD FINISH AS SELECTED BY ARCHITECT SINGLE POLE, DOUBLE THROW SPECIFICATION SINGLE POLE, SINGLE THROW START/STOP SINGLE THROW SWITCHBOARD SWITCHGEAR TWIST LOCK TELEPHONE POLE TWISTED PAIR TELEPHONE TERMINAL BOARD TELEVISION TRANSIENT VOLTAGE SURGE SUPPRESSER TYPICAL UNDER FLOOR UNDERGROUND UNINTERRUPTIBLE POWER SUPPLY VOLTS VOLT AMPERE VARIABLE FREQUENCY CONTROLLER WITH WITHOUT WEATHERPROOF TRANSFORMER GENERAL ELECTRICAL NOTES 1. CLARIFICATION METHODS: AT THE TIME OF BIDDING, BIDDERS SHALL FAMILIARIZE THEMSELVES WITH THE DRAWINGS AND SPECIFICATIONS. ANY QUESTIONS, MISUNDERSTANDINGS, CONFLICTS, DELETIONS, DISCONTINUED PRODUCTS, CATALOG NUMBER DISCREPANCIES, DISCREPANCIES BETWEEN THE EQUIPMENT SUPPLIED AND THE INTENT OR FUNCTION OF THE EQUIPMENT, ETC., SHALL BE SUBMITTED TO THE ENGINEER IN WRITING FOR CLARIFICATION PRIOR TO ISSUANCE OF THE FINAL ADDENDUM AND BIDDING OF THE PROJECT. WHERE DISCREPANCIES OR MULTIPLE INTERPRETATIONS OCCUR, THE MOST STRINGENT THAT MEETS THE INTENT OF THE THAT MEETS THE INTENT OF THE DOCUMENTS SHALL BE ENFORCED. 2. OWNER FURNISHED ITEMS: THE OWNER WILL FURNISH MATERIAL AND EQUIPMENT AS INDICATED IN THE CONTRACT DOCUMENTS TO BE INCORPORATED INTO THE WORK. THESE ITEMS ARE ASSIGNED TO THE INSTALLER AND COSTS FOR RECEIVING, HANDLING, STORAGE (IF REQUIRED) AND INSTALLATION ARE INCLUDED IN THE CONTRACT SUM. A. THE INSTALLER'S RESPONSIBILITIES ARE THE SAME AS IF THE INSTALLER FURNISHED THE MATERIALS OR EQUIPMENT. B. THE OWNER WILL ARRANGE AND PAY FOR DELIVERY OF OWNER FURNISHED ITEMS FREIGHT ON BOARD JOB SITE AND THE INSTALLER WILL INSPECT DELIVERIES FOR DAMAGE. IF OWNER FURNISHED ITEMS ARE DAMAGED, DEFECTIVE OR MISSING, DOCUMENT DAMAGED ITEMS WITH THE TRANSPORT COMPANY AND THE OWNER WILL ARRANGE FOR REPLACEMENT. THE OWNER WILL ALSO ARRANGE FOR MANUFACTURER'S FIELD SERVICES, AND THE DELIVERY OF MANUFACTURER'S WARRANTIES AND BONDS TO THE INSTALLER. C. THE INSTALLER IS RESPONSIBLE FOR DESIGNATING THE DELIVERY DATES OF OWNER FURNISHED ITEMS AND FOR RECEIVING, UNLOADING AND HANDLING OWNER FURNISHED ITEMS AT THE SITE. THE INSTALLER IS RESPONSIBLE FOR PROTECTING OWNER FURNISHED ITEMS FROM DAMAGE, INCLUDING DAMAGE FROM EXPOSURE TO THE ELEMENTS, AND TO REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OF HIS OPERATIONS. REVISIONS: REV NO. DESCRIPTION REV DATE 3. EXPOSED STRUCTURE AREAS (EXCLUDING MECHANICAL, ELECTRICAL, AND COMMUNICATION SPACES): INSTALL RACEWAYS BETWEEN DECK AND STRUCTURE WHEREVER POSSIBLE IN EXPOSED STRUCTURE CEILING AREAS. ROUTE RACEWAYS IN CONCEALED AREAS WHEREVER POSSIBLE. REFER ALL CONDITIONS WHERE RACEWAYS MUST BE INSTALLED WHICH CANNOT COMPLY WITH THESE REQUIREMENTS TO THE ENGINEER. 4. SUBMITTALS: PROVIDE SUBMITTALS IN THREE RING BINDERS WITH JOB NAME, SUBCONTRACTOR, AND VOLUME ON THE BINDING. PREPARE TABS FOR EACH SPECIFICATION SECTION REQUIRING SUBMITTALS. PREPARE INDEX OF EQUIPMENT SUBMITTED IN EACH TAB. ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: SYMBOLS AND LEGENDS SHEET: E-1 ENGINEER STAMP: GENERAL NOTES 1. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC, SIZES AND LOCATION OF EQUIPMENT AND WIRING ARE SHOWN TO SCALE WHERE POSSIBLE, BUT MAY BE DISTORTED FOR CLARITY ON THE DRAWINGS. FINAL LOCATION OF OUTLETS AND EQUIPMENT SHALL BE AS APPROVED BY THE ENGINEER OR HIS REPRESENTATIVE. IT IS NOT WITHIN THE SCOPE OF DRAWINGS TO SHOW ALL NECESSARY BENDS, OFFSETS, PULL BOXES AND OBSTRUCTIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM TO THE STRUCTURE, PRESERVE HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAN. 2. BIDDERS, BEFORE SUBMITTING A PROPOSAL, SHALL VISIT AND CAREFULLY EXAMINE THE AREAS AFFECTED BY THIS WORK TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND WITH THE DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THIS WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD SUCH EXAMINATION BEEN MADE. 3. BIDS SHALL INCLUDE ALL POWER, GROUNDING, AND EMPTY CONDUIT REQUIREMENTS NECESSARY FOR THE COMPLETE ELECTRICAL INSTALLATION. 4. FURNISH AND INSTALL WIRING FOR EQUIPMENT FURNISHED BY OTHERS, AS SHOWN ON MECHANICAL, HVAC, PLUMBING AND/OR ELECTRICAL DRAWINGS. COORDINATE WITH OTHER TRADES FOR DETAILS OF INSTALLATION AND WIRING REQUIREMENTS. THE TERM "WIRING" AS USED HEREIN SHALL INCLUDE FURNISHING AND INSTALLING CONDUIT, WIRES, JUNCTION/OUTLET BOXES, DISCONNECTS, OVER CURRENT PROTECTION AND FINAL CONNECTIONS. COORDINATE FINAL CONDUCTOR SIZES, QUANTITIES, VOLTAGE REQUIREMENTS, AND OVER CURRENT DEVICE AND OUTLET RATINGS WITH ACTUAL EQUIPMENT TO BE FURNISHED TO THE SITE PRIOR TO FINALIZING WIRING INSTALLATION. MINOR ADJUSTMENTS TO WIRING REQUIREMENTS NECESSARY TO ACCOMMODATE ACTUAL FURNISHED EQUIPMENT SHALL BE PROVIDED AT NO ADDITIONAL COST TO OWNER. 5. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS: A. B. C. D. E. F. G. H. I. UNDERWRITERS LABORATORIES, INC. (UL). NATIONAL ELECTRICAL CODE (NEC) NFPA 70. INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS. INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA). NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AMERICAN DISABILITIES ACT (ADA). BUILDING RULES AND REGULATIONS ALL LOCAL JURISDICTION DIRECTIVES AND REQUIREMENTS. 6. THIS CONTRACTOR SHALL DO ALL CUTTING AND PATCHING OF THE EXISTING CONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER INSTALLATION OF THE ELECTRICAL WORK. ALL PATCHING SHALL BE OF THE SAME MATERIALS, WORKMANSHIP AND FINISH AS, AND SHALL ACCURATELY MATCH, ALL SURROUNDING CONSTRUCTION. 7. VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT. IN CENTERING OUTLETS AND LOCATING BOXES OR OUTLETS, ALLOW FOR OVERHEAD PIPES, DUCTS, MECHANICAL EQUIPMENT, VARIATIONS IN FIREPROOFING AND PLASTERING, WINDOW AND DOOR TRIM, PANELING, HUNG CEILING, ETC., AND CORRECT ANY INACCURACY RESULTING FROM FAILURE TO DO SO WITHOUT EXPENSE TO TRILLIUM. 8. LOCATE JUNCTION AND PULL BOXES TO BE CONCEALED IN FINISH SPACES. WHERE NECESSARY, REROUTE RACEWAYS OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. PROVIDE PULL BOXES WHERE NECESSARY FOR WIRE PULLING. COORDINATE ALL BOX LOCATIONS WITH OTHER TRADES. COVERS OF JUNCTION AND PULL BOXES SHALL BE ACCESSIBLE. 9. SECURE ALL SUPPORTS TO BUILDING STRUCTURE AS REQUIRED. SUPPORT HORIZONTAL CONDUIT RUNS AT NO MORE THAN 10' INTERVALS. 10. UPON COMPLETION OF ALL ELECTRICAL WORK, ELECTRICAL CONTRACTOR SHALL ADJUST AND TEST ALL CIRCUITS, OUTLETS, SWITCHES, LIGHTS, MOTORS AND ANY OTHER ELECTRICAL ITEMS INSTALLED. ANY DEFECTIVE ITEMS SHALL BE IMMEDIATELY REPAIRED OR REPLACED WITH NEW EQUIPMENT OR MATERIALS AND THAT PORTION OF THE SYSTEM SHALL BE RETESTED. ALL SUCH REMEDIAL WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE TRILLIUM. TESTING SHALL BE DONE IN ACCORDANCE WITH THE "ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER DISTRIBUTION EQUIPMENT AND SYSTEMS" OF THE INTERNATIONAL ELECTRICAL TESTING ASSOCIATION (NETA). 17. ALL PENETRATIONS THROUGH FIRE RATED WALLS OR FLOORS SHALL BE SEALED TO PREVENT THE SPREAD OF SMOKE AND FIRE. THE FIRE RATING OF THE PENETRATION SEALING METHOD SHALL MATCH THE RATING OF THE WALL OR FLOOR. USE A UL MEA/BSA APPROVED SEALING METHOD WHICH IS ACCEPTABLE TO BUILDING MANAGEMENT. 18. ALL HARD WIRING OF FIRE ALARM SYSTEM SHALL BE DONE BY THIS CONTRACTOR AND SHALL MEET BUILDING AND FIRE DEPARTMENT STANDARDS. 19. UPON COMPLETION OF JOB, CONTRACTOR MUST OBTAIN A LETTER OF ACCEPTANCE OF SYSTEM FROM FIRE DEPARTMENT AND SUBMIT TO TRILLIUM'S REPRESENTATIVE. 20. CONTRACTOR SHALL FURNISH ALL NEW CONDUIT, WIRE, BOXES, ETC., AS REQUIRED AND SHALL RECONNECT ALL EXISTING OUTLETS TO REMAIN. ALL DISTURBED ELECTRICAL WORK TO REMAIN, AFTER REMOVAL OF PARTITIONS, CEILINGS, ETC., SHALL BE REROUTED AND RECONNECTED WITH ALL NEW CONDUITS WIRE, BOXES, OUTLETS, ETC., AS REQUIRED. ALL EXISTING WORK TO REMAIN SHALL BE LEFT IN COMPLETE, OPERATING CONDITION. 21. ABANDONED OUTLETS SHALL BE REMOVED COMPLETE WITH ALL WIRING AND CONDUITS. SAME SHALL BE DISCONNECTED, CUT, AND DEAD-ENDED IN AN APPROVED MANNER. 22. PROVIDE GFI TYPE PROTECTION FOR ANY RECEPTACLES WITHIN 5' OF WATER OR LIQUIDS. 23. ALL WORK ON BRANCH CIRCUITRY, FEEDERS, RISERS, AND EQUIPMENT SHALL BE COMPLETED WITH EQUIPMENT OR CIRCUITS DE-ENERGIZED (SHUT DOWN). 24. FURNISH AND INSTALL INCLUDING LABOR, SUPERVISION, MATERIAL, TOOLS, SERVICES, TRANSPORTATION, OVERHEAD COSTS, FEES, PLAN CHECK FEES, INSPECTION CHARGES, ROYALTIES, PROFIT, ETC., A COMPLETE ELECTRICAL INSTALLATION AS SPECIFIED HEREIN AND INDICATED ON THE ELECTRICAL DRAWINGS IN AN APPROVED, NEAT, FIRST-CLASS, FINISHED, SAFE, WORKMANSHIP LIKE MANNER THAT COMPLIES WITH ALL APPLICABLE LOCAL, STATE, FEDERAL, ETC., CODES, ORDINANCES, RULES, REGULATIONS, STANDARDS, ETC. THE ENTIRE ELECTRICAL INSTALLATION SHALL COMPLY WITH OR SURPASS THE MOST RECENT EDITION OF THE NATIONAL ELECTRICAL CODE AND OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) STANDARDS. 25. ALL MATERIALS AND EQUIPMENT FURNISHED BY THE ELECTRICAL CONTRACTOR SHALL BE NEW OF FIRST CLASS QUALITY, UNLESS NOTED OTHERWISE, FREE FROM DEFECTS, AND CONFORM WITH UNDERWRITERS LABORATORIES, INC. STANDARDS AND BE SO LABELED. MATERIALS, EQUIPMENT, ETC., NOT INDICATED ON DRAWING OR SPECIFIED HEREIN, BUT REQUIRED FOR A SUCCESSFUL AND EFFICIENT COMPLETION OF THE ELECTRICAL INSTALLATION SHALL BE HELD TO BE IMPLIED AND SHALL BE FURNISHED AND INSTALLED FOR NO ADDITIONAL COST. ENCLOSURES FOR ALL EQUIPMENT SHALL BE SUITABLE FOR USE INTENDED, E.G., WEATHERPROOF FOR EXTERIOR AND WET LOCATIONS. ALL EQUIPMENT SHALL BE RATED FOR USE INTENDED, E.G., VOLTAGE, HORSEPOWER, RATING OF DISCONNECT SWITCHES, ETC. 26. MATERIALS, EQUIPMENT, ETC., INCLUDING THOSE FURNISHED BY OTHERS, THAT ARE TO BE INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE RECEIVED AND PROPERLY PROTECTED BY THIS CONTRACTOR UNTIL ENTIRE INSTALLATION IS COMPLETE. 27. MAKE NO INSTALLATION OF WORK WHICH WOULD LEAVE INADEQUATE OPERATION OR SERVICING SPACE FOR ANY ITEM FOR THE ENTIRE PROJECT. DRAWINGS ARE NOT INTENDED TO SHOW IN DETAIL ALL FEATURES OF WORK, CHECK LOCATION AT ELECTRICAL WORK TO DETERMINE IN ADVANCE THAT IT CLEARS ALL OPENINGS, STRUCTURAL MEMBERS, ETC. WHERE CONTRACT DOCUMENTS, E.G., DRAWINGS AND SPECIFICATIONS DO NOT MEET WITH MINIMUM CODES, ETC., THIS CONTRACTOR SHALL INSTALL ALL THE MINIMUM REQUIRED MATERIALS AND EQUIPMENT FOR NO ADDITIONAL COST. 28. ALL WIRING SHALL BE INSTALLED IN APPROVED RACEWAYS PER CODE. RACEWAYS SHALL BE APPROVED FOR USE INTENDED. ALL EMT CONDUIT SHALL HAVE COMPRESSION TYPE FITTINGS. PVC CONDUIT AND FITTINGS FOR ALL UNDERGROUND CONDUITS. ALL ELECTRICAL CONDUCTORS SHOWN ARE COPPER, MINIMUM SIZE IS NO. 12 AWG. INSULATION TO BE THHN/THWN FOR WIRE SIZES #6 AND SMALLER THHN/THWN/XHHW FOR WIRE SIZES #4 AND LARGER. THE USE OF "MC" CABLE IS NOT APPROVED. 12. AFTER COMPLETION OF WORK, CLEAN UP ALL RESULTANT DEBRIS AND REMOVE FROM THE SITE. DISPOSE OF PROPERLY. 13. ALL ABOVE GROUND CONDUIT SHALL BE THREADED RIGID STEEL (RGS), MINIMUM 3/4", UNLESS OTHERWISE NOTED. FLEXIBLE METAL CONDUIT ("GREENFIELD") MAY BE USED ONLY FOR FINAL CONNECTIONS TO LIGHTING FIXTURES OR VIBRATING EQUIPMENT UNLESS OTHERWISE INDICATED ON DRAWINGS. 31. PROVIDE NECESSARY LABOR, TOOLS, EQUIPMENT, E.G., VOLTMETER, AMMETER, MEGGER, ETC., AND CHECK ELECTRICAL SYSTEM IN THE PRESENCE OF THE TRILLIUM'S REPRESENTATIVE. ALL TESTING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATION OF EQUIPMENT, MATERIAL, ETC., BEING TESTED. 14. CONDUCTORS #10 AWG AND SMALLER SHALL BE COPPER, STRANDED, TYPE THHN/THWN; #8 AWG AND LARGER SHALL BE COPPER, STRANDED, TYPE THHN/THWN. ALL WIRING FOR LIGHTING AND POWER SHALL BE #12 AWG MINIMUM. 32. THE ELECTRICAL CONTRACTOR SHALL FULLY GUARANTEE THE ENTIRE ELECTRICAL INSTALLATION AND ALL WORK UNDER THIS SECTION FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER AGAINST ALL EVIDENCE OF IMPERFECT WORKMANSHIP OF FAILURE OR MALFUNCTION OF MATERIALS AND EQUIPMENT. WORK FOUND TO BE DEFECTIVE WITHIN THIS PERIOD SHALL BE REPLACED PROMPTLY AT NO EXPENSE TO THE OWNER. 15. BRANCH CIRCUIT HOME RUN CONDUCTORS SHALL BE INCREASED ONE SIZE (MINIMUM) TO COMPENSATE FOR VOLTAGE DROP FOR 120 VOLT CIRCUITS EXCEEDING 100' FEET AND FOR 277 VOLT CIRCUITS EXCEEDING 150' FEET. 16. ALL CHOPPING FOR ELECTRICAL INSTALLATION SHALL BE COORDINATED WITH CONSTRUCTION MANAGER AND OTHER TRADES. 37. ALL WIRING AND CONDUIT FITTINGS AT DISPENSER, DISPENSER PIT, COMPRESSOR, STORAGE VESSELS AND METER SET ASSEMBLY SHALL BE IN COMPLIANCE WITH HAZARDOUS LOCATION AS DEFINED IN NFPA 70 (NEC) ARTICLE 501 AND NFPA 52 (CNG FUEL SYSTEMS). 38. ALL CONDUIT FITTINGS AND BOXES SHALL BE LISTED AND/OR LABELED BY UNDERWRITERS LABORATORIES OR FACTORY MUTUAL TESTING LABORATORIES. THIS INCLUDES DEVICES, MOTORS AND RELATED ELECTRICAL EQUIPMENT. 39. UNDERGROUND ELECTRICAL CONDUITS SHALL BE PVC CONDUIT AND INSTALLED A MINIMUM OF 8" FROM GAS LINES. ALL BENDS SHALL BE LARGE RADIUS, CONDUIT RUNS OVER 200' WILL HAVE RIGID GALVANIZED STEEL SWEEPS, THAT HAVE BEEN WRAPPED WITH TAPE TO PREVENT CORROSION. 40. CONTRACTOR SHALL VERIFY CONDUIT STUB-UP LOCATION(S) ON PAD PRIOR TO INSTALLATION AND SUBMIT DRAWINGS FOR APPROVAL. ALL CONDUIT STUB-UPS SHALL BE PVC COATED RIDGID STEEL CONDUIT, OR WRAPPED RIDGED STEEL CONDUIT AS APPROVED BY TRILLIUM & OWNER. IF APPROVED, STEEL CONDUIT WILL BE WRAPPED WITH TWO (2) WRAPS OF 20 MIL CONDUIT WRAP. 41. CONTRACTOR MUST VERIFY ALL MEASUREMENTS AFFECTING HIS WORK AND ASSUME THE RESPONSIBILITY FOR THEIR CORRECTNESS. 50. GROUND RODS SHALL BE TESTED FOR RESISTANCE TO GROUND. WHERE RESISTANCE OF ANY SINGLE GROUND ROD EXCEEDS 25 OHMS, ADDITIONAL GROUND ROD(S) SHALL BE DRIVEN. UNTIL GROUND RESISTANCE OF LESS THAN 25 OHMS IS OBTAINED. 51. ALL GROUNDING STUB-UPS IN CONCRETE FOR EQUIPMENT GROUND SHALL BE PROTECTED BY 1" PVC CONDUIT. 52. ALL EQUIPMENT USED IN HAZARDOUS AREAS SHALL BE LISTED AND/OR LABELED FOR USE IN CLASS 1, GROUP D, AND DIVISION 1 OR 2 AS REQUIRED. CONTRACTOR SHALL PATCH, PAINT, REPAIR, AND CLEAN AS REQUIRED TO MATCH SURROUNDING OF ANY SURFACE DISTURBED OR DAMAGED DURING THE DURATION OF THE PROJECT. 53. CONTRACTOR IS RESPONSIBLE FOR TERMINATION OF ALL CONDUCTORS. 54. UNLESS OTHERWISE NOTED, ALL ELECTRICAL COMPONENTS SHALL BE SUPPLIED BY CONTRACTOR. REVISIONS: REV NO. DESCRIPTION 33. ALL CONDUITS ABOVE GROUND SHALL BE RIGID GALVANIZED STEEL UNLESS NOTED OTHERWISE. 34. ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY & COUNTY CODES, NFPA 52 (CNG FUEL SYSTEMS), & NFPA 70 (NEC). 35. ALL WORK SHOWN IS NEW UNLESS OTHERWISE INDICATED. REV DATE 55. ALL CONDUCTORS SHALL BE RATED FOR WET LOCATIONS FOR UNDERGROUND INSTALLATIONS & A MIN. OF THHN FOR ABOVE GROUND INSTALLATION. 56. IN CASE OF A CONFLICT BETWEEN SPECIFICATIONS, NOTES AND GENERAL REQUIREMENTS, OR CODES AND STANDARDS FOR THE INSTALLATION - MOST STRINGENT REQUIREMENTS SHALL GOVERN. OBTAIN CLARIFICATION FROM ENGINEER WHERE CONFLICT IS ENCOUNTERED. 57. SEISMIC REQUIREMENTS: ALL EQUIPMENT PROVIDED SHALL WITHSTAND SEISMIC FORCES DEFINED IN IBC 2012 FOR SEISMIC RISK CATEGORY II AND SEISMIC DESIGN CATEGORY FOR SITE LOCATION . THE TERM "WITHSTAND" MEANS THE UNIT WILL REMAIN IN PLACE WITHOUT SEPARATION OF ANY PARTS FROM THE DEVICE WHEN SUBJECTED TO THE SEISMIC FORCES SPECIFIED AND THE UNIT WILL BE FULLY OPERATIONAL AFTER THE SEISMIC EVENT. ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 29. THIS CONTRACT IS TO INCLUDE ALL CONTINGENCIES WHICH MAY ARISE AND WHICH MAY BE REQUIRED TO MAKE A COMPLETE ELECTRICAL SYSTEM. 30. THE ELECTRICAL CONTRACTOR SHALL VISIT SITE AND DETERMINE EXTENT OF THE WORK. AT COMPLETION OF ELECTRICAL INSTALLATION PROVIDE TRILLIUM WITH ACCURATE AS-BUILT DRAWINGS INDICATING ALL VARIATIONS FROM CONTRACT DRAWINGS, AND A LETTER TO THE OWNER'S REPRESENTATIVE STATING PROJECT FULLY COMPLIES WITH ALL CONTRACT DOCUMENTS AND IF NOT, HOW INSTALLATION WAS ACCOMPLISHED. ALL CHANGES SHALL BE SUBJECT TO TRILLIUM'S REPRESENTATIVE'S APPROVAL. 11. UPON COMPLETION OF ALL ELECTRICAL WORK, ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANEL BOARDS AFFECTED TO WITHIN 10% DEVIATION BETWEEN PHASES. 36. PROVIDE CONDUIT SEALS AT EACH CONDUIT AS REQUIRED BY NFPA 70 (NEC) ARTICLE 501-15. SEALS ARE REQUIRED WITHIN 18" OF ALL GRADE PENETRATIONS WITHIN HAZARDOUS AREAS. ALL CONDUITS SHALL HAVE SEALOFFS WHERE ENTERINR OR LEAVING CLASSIFIED LOCATIONS PER NEC 501. J BARBER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: ELECTRICAL NOTES SHEET: E-2 ENGINEER STAMP: ELECTRICAL SPECIFICATIONS 1. SCOPE OF WORK A. THE WORK UNDER THIS DIVISION INCLUDES PROVIDING ALL MATERIAL AND LABOR NECESSARY FOR A COMPLETE, FUNCTIONAL INSTALLATION OF ELECTRICAL WORK AS SHOWN ON THE DRAWINGS AND AS HEREINAFTER SPECIFIED, UNLESS SPECIFICALLY INDICATED TO THE CONTRARY. THIS CONTRACTOR SHALL ALSO PROVIDE TEMPORARY LIGHT AND POWER FOR ALL TRADES AS REQUIRED BY FIELD CONDITIONS. TEMPORARY POWER PROVISIONS SHALL COMPLY WITH ALL OSHA REQUIREMENTS INCLUDING THOSE FOR GFCI PROTECTION FOR RECEPTACLE CIRCUITS. B. BIDDERS, BEFORE SUBMITTING PROPOSALS, SHALL VISIT THE SITE AND CAREFULLY EXAMINE THE AREAS AFFECTED BY THE WORK IN THIS CONTRACT, AND SHALL FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND ANY DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THIS WORK. 2. CONNECTIONS TO EXISTING WORK SHALL BE PERFORMED AS FOLLOWS: A. INSTALL NEW WORK AND CONNECT TO EXISTING WORK WITH MINIMUM INTERFERENCE TO EXISTING FACILITIES. B. TEMPORARY SHUTDOWNS OF EXISTING SERVICES: 1. AT NO ADDITIONAL CHARGES. 2. AT TIMES NOT TO INTERFERE WITH NORMAL OPERATION OF EXISTING FACILITIES 3. ONLY WITH WRITTEN CONSENT OF BUILDING MANAGEMENT. 8. INSPECTION A. ALL STAGES OF THE INSTALLATION WILL BE INSPECTED FOR COMPLIANCE WITH THE REQUIREMENTS OF THE CONTRACT DRAWINGS AND SPECIFICATIONS. REPLACE ANY PORTION OF THE CONSTRUCTION THAT DOES NOT MEET SUCH REQUIREMENTS TO THE SATISFACTION OF TRILLIUM. B. PROVIDE PROPER FACILITIES AS THE ENGINEER AND INSPECTORS MAY REQUIRE FOR ACCESS AND FOR INSPECTION AT THE CONSTRUCTION SITE. C. CONTRACTOR SHALL PROVIDE ELECTRICIANS TO ASSIST ANY INSPECTORS, MANUFACTURER'S REPRESENTATIVES, AND/OR TESTING AGENCY'S THAT HAVE WORK ON SITE. L. PULL AND SPLICE BOXES SHALL BE CODE GAUGE GALVANIZED STEEL OF SIZE INDICATED OR REQUIRED TO MEET CALIFORNIA CODE SUFFICIENT TO PULL, RACK AND SPLICE CABLES CONTAINED THEREIN. PROVIDE A GROUND LUG WELDED TO BOXES CONTAINING FEEDER CONDUCTORS. M. PROVIDE STEEL CORE NYLON ROPE DRAG LINE WITH TERMINAL BALL IN ALL EMPTY CONDUITS OVER 10' LONG. 11. OUTLET BOXES A. ALL DEVICE PLATES FOR WALL OUTLETS (LIGHTING CONTROL SWITCH, POWER, DATA, TELEPHONE, TV, ETC.) SHALL BE LEVITON WITH SEPARATE SUBPLATE. DEVICE PLATES FOR TELEPHONE, DATA AND TV OUTLETS SHALL CONTAIN APPROPRIATE JACKS; COORDINATE WITH TRILLIUM. 9. CUTTING AND PATCHING A. ALL CUTTING AND PATCHING REQUIRED FOR EQUIPMENT INCLUDED IN THESE SPECIFICATIONS SHALL BE DONE BY THIS CONTRACTOR. IF CUTTING IS DONE DUE TO FAILURE TO PERFORM PRELIMINARY ROUGHING WORK, THIS CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF THE ADDITIONAL PATCHING. B. IN THOSE PARTITIONS OF THE BUILDING WHERE NEW FLOORS, WALLS OR PARTITIONS ARE REQUIRED TO BE CONSTRUCTED, THE CONTRACTOR SHALL FURNISH AND LOCATE ALL REQUIRED SLEEVES CONSTRUCTED. WHERE SLEEVES AND INSERTS WERE NOT INSTALLED, OR WHERE SLEEVES AND INSERTS WERE INCORRECTLY LOCATED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF ANY REQUIRED CUTTING AND PATCHING. B. PROVIDE TELCOM DEVICE PLATE FOR EACH VOICE/DATA OUTLET. FINAL CONFIGURATION OF TERMINATION DEVICES SHALL BE AS PER OWNER'S REQUIREMENTS. C. ALL CONVENIENCE TYPE RECEPTACLES SHALL BE OF THE GROUNDING TYPE. D. IN GENERAL, THE MOUNTING HEIGHTS OF THE VARIOUS OUTLETS SHALL BE AS SHOWN ON DRAWINGS. IN CERTAIN LOCATIONS, THE REQUIRED HEIGHTS WILL VARY TO ACCOMMODATE EQUIPMENT TO BE LOCATED PROPERLY IN THE DRAWINGS, OR SHALL BE DETERMINED AT THE CONSTRUCTION SITE BY TRILLIUM'S REPRESENTATIVE. E. CEILING OUTLET BOXES MUST BE ACCESSIBLE FROM FIXTURE SERVED. C. ALARM AND EMERGENCY SYSTEMS: NOT TO BE INTERRUPTED. D. MAINTAIN CONTINUOUS OPERATION OF EXISTING FACILITIES AS REQUIRED WITH NECESSARY TEMPORARY CONNECTIONS BETWEEN NEW AND EXISTING WORK. E. CONNECT NEW WORK TO EXISTING WORK IN NEAT AND ACCEPTABLE MANNER. RESTORE EXISTING DISTURBED WORK TO ORIGINAL CONDITION INCLUDING MAINTENANCE OF WIRING CONTINUITY AS REQUIRED. 3. REMOVAL AND RELOCATION OF EXISTING WORK: A. DISCONNECT, REMOVE AND/OR RELOCATE EXISTING MATERIAL, EQUIPMENT, AND OTHER WORK AS NOTED OR REQUIRED FOR PROPER INSTALLATION OF NEW SYSTEM. B. DISPOSE OF REMOVED ELECTRICAL EQUIPMENT AS DIRECTED IN ACCORDANCE WITH LOCAL CODES AND STANDARDS. 4. CODES AND STANDARDS A. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES AND STANDARDS: A. B. C. D. E. F. G. H. I. J. K. UNDERWRITERS LABORATORIES, INC. (UL) NATIONAL ELECTRICAL CODE OF THE NFPA (NEC) ELECTRICAL CODE 2011 EDITION INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS INTERNATIONAL FIRE CODE WITH LOCAL AMENDMENTS OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA) NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) AMERICAN DISABILITIES ACT (ADA) BUILDING RULES AND REGULATIONS. ALL LOCAL JURISDICTION DIRECTIVES AND REQUIREMENTS. INTERNATIONAL ELECTRICAL TESTING ASSOCIATION INC. ACCEPTANCE TESTING SPECIFICATI0NS. 5. SHOP DRAWINGS AND CATALOG CUTS A. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO TRILLIUM FOR APPROVAL, DETAILED SHOP DRAWINGS, CATALOG CUTS AND WIRING DIAGRAMS FOR THE FOLLOWING: 1. 2. 3. 4. 5. 6. PANEL BOARDS DISCONNECT SWITCHES LIGHTING FIXTURES WIRING DEVICES TRANSFORMERS CONDUIT FITTINGS, GROUNDING EQUIPMENT 6. SUBSTITUTIONS A. ANY SUBSTITUTIONS FOR ELECTRICAL ITEMS DESCRIBED IN THIS SPECIFICATION WILL ONLY BE PERMITTED UPON WRITTEN PRIOR APPROVAL BY TRILLIUM. BASE BID SHALL BE FOR SPECIFIED EQUIPMENT. B. REQUESTS FOR APPROVAL OF SUBSTITUTIONS FOR ITEMS OF LESSER MATERIAL AND/OR LABOR COSTS THAN THOSE SPECIFIED MUST BE ACCOMPANIED BY AN ITEMIZED COST SAVINGS BREAKDOWN TO BE CONSIDERED. 7. QUALITY ASSURANCE A. THE CONTRACTOR SHALL HAVE HAD EXPERIENCE ON AT LEAST FIVE PROJECTS INVOLVING QUANTITIES AND COMPLEXITIES AT LEAST EQUAL TO THOSE REQUIRED FOR UNDER THIS DIVISIONS OR THE APPLICABLE SECTION THEREOF. B. ALL WORKMEN PERFORMING UNDER THIS DIVISIONS SHALL BE SKILLED WORKMEN OF THE TRADE INVOLVED. C. THIS CONTRACTOR SHALL NOT DO ANY CUTTING THAT MAY IMPAIR THE STRENGTH OF BUILDING CONSTRUCTION. NO HOLES ARE TO BE DRILLED INTO THE TENSION SIDE OF STRUCTURAL MEMBERS. CLAMPS AND OTHER APPROVED HOLDING DEVICES ARE TO BE USED. ALL WORK SHALL BE DONE IN A NEAT MANNER BY MECHANICS SKILLED IN THEIR TRADES AND AS APPROVED. 10. RACEWAYS AND BOXES A. WHERE SIZES OF RACEWAY OR BOXES ARE NOT INDICATED, THE CONTRACTOR SHALL SIZE THESE ITEMS AS REQUIRED FOR THE INSTALLATION. ALL ABOVE GROUND CONDUIT SHALL BE RIGID THREADED STEEL MINIMUM 3/4" UNLESS OTHERWISE NOTED. B. FITTINGS FOR RIGID CONDUIT SHALL BE OF THE THREADED TYPE. FITTINGS FOR STEEL CONDUIT SHALL BE HOT DIPPED GALVANIZED MALLEABLE IRON. FITTINGS FOR FLEXIBLE CONDUIT SHALL BE STEEL WITH NYLON INSULATED THROATS. C. FLEXIBLE METAL CONDUIT SHALL BE USED FOR FINAL CONNECTION OF RECESSED LIGHTING FIXTURES AND OUTLET BOXES IN HUNG CEILINGS, AND WIRING DEVICES INDICATED TO BE INSTALLED IN HUNG CEILINGS OR IN REMOVABLE HOLLOW METAL STUD PARTITION CONSTRUCTION. D. LIQUID TIGHT GALVANIZED FLEXIBLE STEEL CONDUIT, MINIMUM 18 INCHES LONG, MAXIMUM 36 INCHES LONG, SHALL BE PROVIDED AT ROTATING EQUIPMENT AND TRANSFORMER CONNECTIONS. E. ALL CONDUIT AND TUBING SHALL BE CUT SQUARE AND REAMED AT THE ENDS. F. PAINT MALE THREADS OF FIELD THREADED RACEWAYS WITH GRAPHITE BASE PIPE COMPOUND. DRAW UP TIGHT WITH COUPLINGS WITH NO EXPOSED THREADS. G. CONDUIT AND TUBING RUNS SHALL BE MECHANICALLY AND ELECTRICALLY CONTINUOUS FROM THE POINT OF SERVICE TO THE LAST OUTLETS. CONDUIT SHALL ENTER AND BE SECURELY CONNECTED TO CABINET, JUNCTION BOX, PULL BOX OR OUTLET BOX BY MEANS OF LOCK NUTS ON THE OUTSIDE AND INSIDE AND PROVIDED WITH AN INSULATED BUSHING ON THE INSIDE. IN TUBING OR FLEXIBLE METAL CONDUIT, THE ONE COMPRESSION LOCK NUT SHALL BE MADE WRENCH-TIGHT. ALL LOCK NUTS SHALL BE OF THE BONDING TYPE WITH SHARP EDGES AND DIGGING INTO THE METAL WALL OF AN ENCLOSURE AND SHALL BE INSTALLED IN A MANNER THAT WILL ASSURE A LOCKING AND ELECTRICALLY CONTINUOUS INSTALLATION. LOCK NUTS AND BUSHINGS WILL NOT BE REQUIRED WHERE CONDUITS ARE SCREWED INTO TAPPED CONNECTIONS. H. ALL VERTICAL RUNS OF CONDUIT OR TUBING TERMINATING IN THE BOTTOMS OF WALL BOXES OR CABINETS, OR SIMILAR LOCATIONS, SHALL BE PROTECTED FROM THE ENTRANCE OF FOREIGN MATERIAL PRIOR TO THE INSTALLATION OF CONDUCTORS. I. UNLESS OTHERWISE SPECIFIED, ALL CONDUIT AND TUBING SHALL BE INSTALLED CONCEALED. IN GENERAL, ALL CONDUIT AND TUBING SHALL BE RUN IN HUNG CEILINGS AND FURRED SPACES, WHERE THEY EXIST. WHERE CONDUIT IS RUN EXPOSED, IT SHALL BE SECURELY SUPPORTED WITH ZINC COATED MALLEABLE IRON PIPE STRAPS OR OTHER APPROVED MEANS. CONDUITS SHALL NOT BE RUN WITHIN ONE FOOT OF AND PARALLEL TO HOT WATER PIPES. CONDUITS SHALL BE RUN PARALLEL OR PERPENDICULAR TO BUILDING STRUCTURAL ELEMENTS. 15. WIRING A. UNLESS OTHERWISE SPECIFIED OR SPECIFICALLY INDICATED ON THE DRAWINGS, ALL CONDUCTORS FOR LIGHTING AND POWER SHALL BE TINNED SINGLE CONDUCTOR ANNEALED COPPER BUILDING WIRES OF MINIMUM 98% CONDUCTIVITY WITH DISTINCTIVE COLOR MARKING, 600 VOLT INSULATION, COLOR CODED AS SPECIFIED HEREINAFTER. CONDUCTORS #10 AWG AND SMALLER SHALL BE STRANDED, TYPE THHN/THWN; #8 AWG AND LARGER SHALL BE STRANDED, TYPE THHN/THWN. B. WIRING FOR LIGHTING AND POWER SHALL BE #12 AWG MINIMUM. CONTROL WIRING SHALL BE #12 AWG MINIMUM, UNLESS OTHERWISE INDICATED. C. BRANCH CIRCUIT HOME RUN CONDUCTORS SHALL BE INCREASED ONE SIZE (MINIMUM) TO COMPENSATE FOR VOLTAGE DROP FOR 120 VOLT CIRCUITS EXCEEDING 100' AND 277 VOLT CIRCUITS EXCEEDING 140'. D. ALL WIRES AND CABLES FOR BOTH LIGHTING AND POWER SHALL BE PHASED OUT AND CONNECTED IN SUCH MANNER THAT CABLES HAVING INSULATION OF THE SAME COLOR WILL BE CONNECTED TO THE SAME PHASE THROUGHOUT. WIRE JOINTS THAT BECOME NECESSARY IN CIRCUIT WORK AT THE OUTLETS SHALL BE MADE WITH APPROVED PRESSURE CONNECTORS AS MANUFACTURED BY SCOTCH-LOCK, BUCHANAN, T&B OR APPROVED EQUAL. ALL JOINTS SHALL BE COVERED WITH TAPE OF AN INSULATION EQUAL TO THAT OF THE CONDUCTORS. E. ALL WIRES 1/0 AND LARGER WILL BE MEGGERED TO ENSURE INSULATION INTEGRITY BY CONTRACTOR. CONTRACTOR WILL SUBMIT A REPORT TO TRILLIUM STATING COMPLIANCE AND RESULTS OF TEST. 12. WIRING DEVICES 16. COLOR CODING A. WIRING DEVICES SHALL BE OF THE MOLDED COMPOSITION TYPE, INDUSTRIAL SPECIFICATION GRADE, UNLESS OTHERWISE INDICATED. WIRING DEVICES SHALL BE AS MANUFACTURED BY LEVITON, LUTRON, HUBBELL, RUSSELL STOLL OR APPROVED EQUAL. ALL WIRING DEVICES SHALL BE WHITE IN GENERAL UNLESS OTHERWISE SELECTED BY TRILLIUM OR OTHERWISE INDICATED IN CONTRACT DOCUMENTS FOR SPECIFIC FUNCTIONS. B. WALL SWITCHES SHALL BE INDUSTRIAL SPECIFICATION GRADE AND SHALL HAVE ALTERNATING CURRENT RATINGS EQUAL TO FULL NOMINAL CAPACITY WHEREVER HANDLING TUNGSTEN FILAMENT OR INDUCTIVE LOADS AND THEN SHALL BE OF THE FLUSH QUIET TUMBLER TYPE. SWITCHES SHALL BE WHITE IN COLOR (OR COLOR AS SELECTED BY TRILLIUM) OR OTHER COLOR TO INDICATE SPECIAL FUNCTION. 1. 120/277 VOLT AC, 20 AMP, SINGLE POLE, ROCKER TYPE, SELF GROUNDING LEVITON# 5621-2 2. 120/277 VOLT AC, 20 AMP, THREE WAY, ROCKER TYPE, SELF GROUNDING LEVITON# 5623-2 3. 20 AMP, AC, PILOT TYPE, ROCKER TYPE, SELF GROUNDING, 120V SINGLE POLE - LEVITON #5628-2, 120V THREE WAY - LEVITON #5638-2, 277V SINGLE POLE - LEVITON #5629-2, 277V THREE WAY - LEVITON #5639-2, C. RECEPTACLES SHALL BE INDUSTRIAL SPECIFICATION GRADE OF THE NEMA STANDARD CONFIGURATION FOR EACH APPLICATION USING A HORSESHOE SHAPED GROUNDING POLE, AS FOLLOWS: 1. 120 VOLT CONVENIENCE: DUPLEX RECEPTACLE, 15 AMPERE 125 VOLT RATED, PARALLEL BLADE AND U SHAPED GROUNDING CONTACT, SIDE WIRED. LEVITON 16242. 2. 120 VOLT APPLIANCE: DUPLEX RECEPTACLE, 20 AMPERE 125 VOLT RATED, PARALLEL BLADE AND U SHAPED GROUNDING CONTACT, SIDE WIRED. LEVITON 16342 3. OTHER RECEPTACLE TYPES AS REQUIRED SHALL BE SPECIFIED ON DRAWINGS OR SYMBOLS LIST. D. ALL RECEPTACLES AND SWITCHES SHALL BE SIDE WIRED WITH CONDUCTORS TERMINATED AT SCREW TERMINALS. PUSH IN WIRING WILL NOT BE PERMITTED. E. SWITCHES SHALL BE INSTALLED AT THE STRIKE SIDE DIRECTLY ADJACENT TO THE ENTRANCE DOOR OF THE ROOM. CHECK THE DRAWINGS FOR DOOR SWINGS SO THAT ALL SWITCHES SHALL BE LOCATED ON THE LOCK SIDE OF THE OPENINGS. F. ALL DEVICE PLATES FOR WALL OUTLETS (LIGHTING CONTROL SWITCH, POWER, DATA, TELEPHONE, TV, ETC.) SHALL BE LEVITON. DEVICE PLATES FOR TELEPHONE, DATA AND TV OUTLETS SHALL CONTAIN APPROPRIATE JACKS; COORDINATE WITH ENGINEER AND OWNER. 13. GROUNDING A. TRANSFORMERS, METAL RACEWAYS, METAL ENCLOSURES OF ELECTRICAL DEVICES LIGHTING FIXTURES, ELECTRICAL EQUIPMENT AND OTHER EQUIPMENT SHALL BE COMPLETELY GROUNDED IN AN APPROVED MANNER TO NEAREST EFFECTIVELY GROUNDED BUILDING STEEL OR COLD WATER PIPE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE APPLICABLE CODES AND AUTHORITIES. THIS IS IN ADDITION TO THOSE GROUNDING CONDUCTORS REQUIRED BY THE DRAWINGS. J. CONDUIT SYSTEMS SHALL BE INSTALLED COMPLETE BEFORE ANY CONDUCTORS ARE DRAWN IN. WIRE PULLING LUBRICANTS, WHEN UTILIZED, SHALL BE IN ACCORDANCE WITH UL REQUIREMENTS REGARDING THE SPECIFIC CONDUCTOR OR CABLE INSULATION AND RACEWAY MATERIAL. 14. EQUIPMENT MOUNTING K. SHERARDIZED OR HOT DIPPED GALVANIZED STAMPED STEEL OR ELECTRO-GALVANIZED CAST IRON OR COPPER FREE CAST ALUMINUM ALLOY OUTLET BOXES SHALL BE PROVIDED FOR EVERY OUTLET CALLED FOR ON DRAWINGS, SUITABLE FOR THE NUMBER AND ARRANGEMENT OF CONDUITS, CABLES, LOCATION, ETC. WHERE REQUIRED AND APPROVED BY ENGINEER, EXTRA DEEP OR EXTRA SHALLOW OUTLET BOXES SHALL BE USED TO FACILITATE THE INSTALLATION OF THE CONDUIT SYSTEM. A. PROVIDE INSERTS, EXPANSION SHIELD LUGS, ANCHORS, BOLTS WITH NUTS AND WASHER SHIM OR ANY OTHER TYPE OF FASTENING DEVICES REQUIRED TO FASTEN PANELS OR OTHER EQUIPMENT, TO FOUNDATIONS, FLOORS, WALLS OR CEILINGS. UNLESS OTHERWISE SPECIFIED HEREIN OR SHOWN ON THE CONTRACT DRAWINGS, ALL FASTENERS SHALL BE HOT DIPPED GALVANIZED AND OF SIZES AND TYPES RECOMMENDED BY THE EQUIPMENT MANUFACTURER AND AS APPROVED BY TRILLIUM. B. ALL PROPER HARDWARE REQUIRED FOR A COMPLETE GROUNDING SYSTEM SHALL BE INSTALLED BY THE CONTRACTOR. A. THE CONTRACTOR SHALL MATCH THE COLOR-CODING THAT IS BEING USED IN THE BUILDING, IF APPLICABLE, OR AS FOLLOWS (DEVIATION DUE TO LIMITED QUANTITIES OF CABLE MAY BE PERMITTED UPON WRITTEN APPROVAL BY THE ENGINEER): SYSTEM VOLTAGE PHASE A B C NEUTRAL GROUND ISOLATED GROUND 277/480V BROWN ORANGE YELLOW GRAY GREEN - 120/208V BLACK RED BLUE WHITE GREEN GREEN/YELLOW STRIPE REVISIONS: REV NO. DESCRIPTION REV DATE 17. IDENTIFICATION EQUIPMENT AND CONDUCTORS SHALL BE IDENTIFIED AS FOLLOWS: A. ALL MAJOR COMPONENTS OF THE DISTRIBUTION SYSTEM SUCH AS STARTERS, DISCONNECT SWITCHES, PANEL BOARD, ETC, MUST HAVE NAMEPLATES WITH EQUIPMENT IDENTIFICATION, VOLTAGE AND PHASE RATINGS AND SOURCE OF FEED OR CIRCUIT UTILIZATION. PANEL BOARDS SHALL HAVE TYPED DIRECTORIES. B. ALL STARTERS, DISCONNECT SWITCHES AND CONTROLS SHALL HAVE NAMEPLATES IDENTIFYING THE EQUIPMENT SERVED. NAMEPLATES SHALL BE LAMINATED PHENOLIC, WITH WHITE LETTERS ON A BLACK FIELD SECURED WITH FLUSHED FASTENINGS. LETTERS TO BE 1/4" HIGH, MINIMUM. C. ALL WIRES SHALL BE IDENTIFIED BY CIRCUITS IN ALL CABINETS, BOXES, WIRING TROUGH AND OTHER ENCLOSURES, AND AT ALL TERMINAL POINTS (I.E., RECEPTACLES, ETC.). D. THE CIRCUIT DESIGNATIONS SHALL BE AS SHOWN ON THE CONTRACT DRAWINGS OR AS DIRECTED BY THE ENGINEER. TAGS SHALL BE ATTACHED TO WIRES SO THAT THEY WILL BE READILY VISIBLE. ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 E. BRADY-B500 VINYL CLOTH WIRE AND TERMINAL MARKERS SHALL BE USED FOR ALL WIRE IDENTIFICATION OR APPROVED EQUAL. F. ALL CONDUCTORS TO BE IDENTIFIED WITH NON-REPETITIVE NUMBERS, ALL CONDUCTORS TO BE IDENTIFIED ON BOTH ENDS, AND WITHIN 18" OF CONDUIT ENTRANCE OF ENCLOSURE. 18. SAFETY SWITCHES A. SAFETY TYPE DISCONNECTING SWITCHES SHALL BE RATED AT 250 OR 600 VOLTS AS REQUIRED BY THE UTILIZATION VOLTAGE AND SHALL BE QUICK-MAKE, QUICK-BREAK TYPE, HORSEPOWER RATED. SWITCHES SHALL BE MANUFACTURED BY AMERICAN CIRCUIT BREAKER CORP., SIEMENS, SQUARE D, OR APPROVED EQUAL. PROVIDE HEAVY DUTY SWITCHES J BARBER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: B. ALL PARTS OF THE SWITCH SHALL BE MOUNTED ON INSULATED BASE TO PERMIT REPLACEMENT OF ANY PARTS FROM THE FRONT OF THE SWITCH. ALL CURRENT CARRYING PARTS SHALL BE OF HIGH CONDUCTIVITY COPPER, DESIGNED TO CARRY RATED LOAD WITHOUT EXCESSIVE HEATING. SWITCH CONTACTS SHALL BE SILVER TUNGSTEN TYPE OR PLATED TO PREVENT CORROSION, PITTING AND OXIDATION AND TO ASSUME SUITABLE CONDUCTIVITY. FUSE CLIPS, WHERE REQUIRED, SHALL BE OF THE POSITIVE PRESSURE REJECTION TYPE. SWITCHES SHALL BE CAPABLE OF WITHSTANDING THE AVAILABLE FAULT CURRENT OR LET-THROUGH CURRENT BEFORE THE FUSE OPERATES WITHOUT DAMAGE OR CHANGE IN RATING. PROVIDE GROUND LUGS IN ALL SWITCHES. PROVIDE INTERLOCKING COVER WHICH NORMALLY CANNOT BE OPENED WHEN SWITCH IS IN "ON" POSITION AND WITH MEANS OF BYPASSING THE MECHANICALLY INTERLOCK DOOR AND HANDLE. ELECTRICAL NOTES SHEET: E-3 C. LUGS SHALL BE RATED FOR THE USE OF CABLES WITH EITHER 75 DEG. C OR 90 DEG. C INSULATION WITHOUT DERATING. MULTI-BARREL LUGS SHALL BE PROVIDED TO ACCOMMODATE PARALLEL FEEDER CABLES AND/OR TAPS AS REQUIRED. "DOUBLE LUGGING" WILL NOT BE PERMITTED. D. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL DISCONNECT SWITCHES, COPPER DETAIL, TROUGH, ETC., AS SHOWN IN ELECTRICAL DRAWINGS, AND WIRING BETWEEN ALL DISCONNECT SWITCHES, STARTERS, LIGHTING AND POWER PANELS AS WELL AS TO ALL MECHANICAL EQUIPMENT AS SHOWN IN ELECTRICAL DRAWINGS. 19. FUSES A. FUSES SHALL BE OF THE RATINGS SHOWN ON THE DRAWINGS AND THEY SHALL BE UL LISTED. WHERE SIZES ARE NOT SHOWN, THEY SHALL BE OF REQUIRED SIZE FOR PROPER OPERATION OF EQUIPMENT PROTECTED. B. ALL FUSES SHALL HAVE AN INTERRUPTING CAPACITY AS REQUIRED TO INTERRUPT THE AVAILABLE SHORT CIRCUIT CURRENT. CURRENT LIMITING FUSES SHALL BE PROVIDED. C. THE TIME CURRENT CHARACTERISTICS AND RATINGS OF FUSES SHALL BE SUCH THAT POSITIVE SELECTIVE COORDINATION IS ASSURED. 2. RIGID CONDUIT WITH EXPLOSION PROOF JOINTS AND FITTINGS SHALL BE EMPLOYED AS THE TYPE OF WIRING. WHERE IT IS NECESSARY TO EMPLOY FLEXIBLE CONNECTIONS, AS AT MOTOR TERMINALS, A FLEXIBLE FITTING OF THE EXPLOSION PROOF TYPE SHALL BE USED. AT POINTS WHERE CONDUIT TERMINATES IN AN ENCLOSURE IN WHICH ARCING OR SPARKING IS LIKELY TO OCCUR, SUCH AS AT MOTOR TERMINALS, SWITCH BOXES AND THE LIKE, AND WHEREVER A CONDUIT LEADS FROM A HAZARDOUS TO A NONHAZARDOUS LOCATION, THE CONDUIT SHALL BE SEALED OFF BY A SEALING COMPOUND WHICH IS NOT AFFECTED BY THE SURROUNDING ATMOSPHERE OR LIQUIDS, AND WHICH HAS A MELTING POINT OF NOT LESS THAN TWO HUNDRED DEGREES FAHRENHEIT. THE SEALING COMPOUND SHALL HAVE A THICKNESS OF NOT LESS THAN FIVE-EIGHTHS INCH. JOINTS IN RIGID CONDUIT MADE WITH THREADED COUPLINGS HAVING FIVE FULL THREADS ENGAGED ARE RECOGNIZED AS BEING EXPLOSION PROOF. 3. FUSES SHALL NOT BE INSTALLED UNLESS MOUNTED WITHIN EXPLOSION PROOF ENCLOSURES. THE FUSE CUTOUT BASES AND THEIR ENCLOSURES SHALL BE APPROVED AS UNIT DEVICES FOR USE IN CLASS 1, DIV 1 AREAS. CIRCUIT BREAKERS, IF USED, SHALL BE OF A TYPE APPROVED FOR USE IN CLASS 1, DIV 1 AREAS. C. ALL LUMINARIES AND LIGHTING EQUIPMENT SHALL BE DELIVERED TO THE PREMISES COMPLETE, INCLUDING ALL MOUNTING ACCESSORIES AND COMPONENTS NECESSARY FOR THE PROPER OPERATION OF THE EQUIPMENT EXCLUSIVE OF LAMPS. D. ALL FIXTURES AND COMPONENTS SHALL BE MADE IN ACCORDANCE WITH THE NEC AND CALIFORNIA CODE AND SHALL CONFORM TO ALL APPLICABLE UL REQUIREMENTS. E. LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, WESTINGHOUSE, OSRAM/SYLVANIA OR PHILLIPS. ALL FLUORESCENT LAMPS SHALL BE ENERGY SAVING TYPE. INCANDESCENT LAMPS (INCLUDING ANY HALOGEN TYPE) SHALL BE 130 VOLT RATED, LONG LIFE TYPE. PROVIDE ALL LAMPS REQUIRED. PROVIDE ONE SPARE LAMP OF EACH TYPE UTILIZED IN THE PROJECT. F. ALL LAMPS INCLUDING FLUORESCENT TUBES, INCANDESCENT BULBS, ETC., ARE TO BE GUARANTEED FOR A MINIMUM 3 MONTH PERIOD. DURING THIS THREE MONTH PERIOD THE CONTRACTOR IS TO REPLACE, AT NO COST TO THE OWNER, ANY "BURNED-OUT" LAMPS. THE THREE MONTH PERIOD IS TO COMMENCE AT THE COMPLETION OF THE PAINTING PHASE OF THE PROJECT. 4. MOTORS SHALL BE CLASS 1,DIV 1 RATED. INSTALLATION AND LOCATING OF FIXTURES 20. PANEL BOARDS A. PANEL BOARDS SHALL BE DESIGNED FOR THE SPECIFIED VOLTAGES AND NUMBER OF CIRCUIT BREAKERS AS SHOWN IN THE SCHEDULES. PANEL BOARD INTERIORS AND CIRCUIT BREAKERS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, EATION/CUTLER-HAMMER, AMERICAN CIRCUIT BREAKER CORP., SIEMENS, SQUARE D OR APPROVED EQUAL. B. PANEL BOARD CABINETS SHALL BE OF THE GENERAL PURPOSE DEAD FRONT TYPE FOR FLUSH OR SURFACE MOUNTING AS INDICATED ON THE DRAWINGS. TRIM OF PANEL BOARD FRONT SHALL BE MADE OF COLD ROLLED SHEET STEEL OF NOT LESS THAN 12 GAUGE PROVIDED WITH A COAT OF ZINC CHROMATE PRIMER AND ONE FINISH COAT OF ANSI-61LIGHT GRAY ENAMEL. TRIMS SHALL HAVE FLUSH CLOSING DOORS OF SHEET STEEL HAVING CONCEALED CONTINUOUS HINGES COMPLETE WITH CHROME PLATED FLUSH TYPE COMBINATION LOCK AND CATCH. ALL CNG PANELS SHALL BE KEYED ALIKE. GUTTER SPACE SHALL CONFORM TO CALIFORNIA CODE REQUIREMENTS. C. BUS BARS SHALL BE OF HARD DRAWN COPPER AND SHALL EXTEND FULL HEIGHT OF PANEL. PROVIDE A SEPARATE AND ISOLATED GROUND BUS IN ADDITION TO THE NEUTRAL BUS WHERE INDICATED IN THE SCHEDULES. D. THE PHASE BUS TO WHICH EACH SINGLE POLE BRANCH IS CONNECTED SHALL BE SO ARRANGED THAT THE SAME RELATIONSHIP OF PHASE SEQUENCE IS MAINTAINED FOR EACH CONSECUTIVE POLE. E. CIRCUIT BREAKERS SHALL BE BOLT-DOWN TYPE. MINIMUM AIC RATING SHALL BE 10,000 A FOR 250 VOLT CLASS AND 14,000 A FOR 600 VOLT CLASS OR AS INDICATED IN THE SCHEDULE. CIRCUIT BREAKERS SHALL BE IN ACCORDANCE WITH AVAILABLE SHORT CIRCUIT CURRENT. F. PROVIDE HACR TYPE CIRCUIT BREAKERS FOR HVAC EQUIPMENT CIRCUITS. G. ALL PANEL BOARDS SHALL BE BALANCED TO WITHIN 10% DEVIATION BETWEEN PHASES PRIOR TO FINAL PAYMENT, IN SO FAR AS IS POSSIBLE. H. ALL LUGS, BUSSING, AND SECTIONS WILL BE TORQUED ACCORDING TO PANEL BOARD MANUFACTURES RECOMMENDATIONS. CONTRACTOR TO SUBMIT A REPORT TO TRILLIUM STATING COMPLIANCE AND TORQUE SETTINGS. 21. DRY TYPE TRANSFORMERS A. TRANSFORMERS SHALL BE DRY TYPE, TWO WINDING, DESIGNED FOR 460V DELTA PRIMARY, 208/120V WYE SECONDARY, 3 PHASE, 60 HZ SERVICE. OPEN DELTA OR T-WOUND TRANSFORMERS WILL NOT BE ACCEPTABLE. B. ALL INSULATED MATERIALS SHALL BE 200 DEGREES C CLASS. C. TRANSFORMERS SHALL BE DESIGNED NOT TO EXCEED 115 DEGREES RISE ABOVE 40 DEGREES C AMBIENT TEMPERATURE AT FULL LOAD. D. TRANSFORMER SHALL HAVE A MINIMUM OF FOUR 2-1/2% FULL CAPACITY TAPS, TWO ABOVE AND TWO BELOW NORMAL. E. WINDINGS SHALL BE COPPER. F. TRANSFORMERS SHALL BE AS MANUFACTURED BY GENERAL ELECTRIC, EATON/CUTLER HAMMER, SORGEL, SQUARE D OR APPROVED EQUAL. G. PROVIDE SYSTEM AND EQUIPMENT GROUNDING IN ACCORDANCE WITH NEC. H. CONNECT ISOLATED GROUNDING CONDUCTORS TO TRANSFORMER NEUTRAL GROUNDING POINT, AS REQUIRED. 22. ELECTRICAL CODE CLASS I DIVISION 1 LOCATION REQUIREMENTS A. IN CLASS I LOCATIONS, THE FOLLOWING PROVISIONS SHALL BE OBSERVED: 1. NO SERVICE ENTRANCE EQUIPMENT, SWITCHBOARDS OR PANEL BOARDS SHALL BE INSTALLED UNLESS OF A TYPE APPROVED FOR USE IN CLASS 1, DIV 1 AREAS. 5. MOTOR CONTROLLERS, THERMAL CUTOUTS, SWITCHES, RELAYS, THE SWITCHES AND CONTACTORS OF AUTO TRANSFORMER STARTERS, RESISTANCE OR IMPEDANCE DEVICES OR OTHER DEVICES OR APPARATUS WHICH, IN THEIR NORMAL OPERATION, TEND TO CREATE ARCS, SPARKS, OR HIGH TEMPERATURES, SHALL NOT BE INSTALLED UNLESS SUCH DEVICES OR APPARATUS ARE OF A TYPE APPROVED FOR USE IN CLASS 1, DIV 1 AREAS. MOTOR CONTROLLERS SHALL PREFERABLY BE OF THE REMOTE CONTROL TYPE WITH THE MAIN CONTACTORS LOCATED AT A POINT WHERE THE HAZARDOUS CONDITIONS OF THIS CLASS DO NOT PREVAIL. AUXILIARY CONTROL PUSH BUTTON OR SWITCHES OF A TYPE APPROVED FOR USE IN CLASS 1, DIV 1 AREAS MAY BE PLACED IN THE MOST CONVENIENT LOCATIONS. 6. ELECTRIC HEATING APPLIANCES SHALL NOT BE USED UNLESS OF A TYPE APPROVED FOR THE PARTICULAR LOCATION OR TYPE OF MATERIAL IN OR WITH WHICH THEY ARE USED. 7. SWITCHES CONTROLLING LIGHTING CIRCUITS SHALL NOT BE INSTALLED UNLESS OF A TYPE APPROVED FOR USE IN CLASS 1, DIV 1 AREAS. G. FIXTURE LOCATION AS INDICATED ON THE ELECTRICAL DRAWINGS IS GENERALIZED AND APPROXIMATE. THE CONTRACTOR SHALL CAREFULLY VERIFY FIXTURE LOCATION WITH TRILLIUM REPRESENTATIVE, REFLECTED CEILING PLAN AND OTHER REFERENCE DATA PRIOR TO INSTALLATION. H. CEILING JUNCTION BOXES MUST BE ACCESSIBLE FROM FIXTURE SERVED. 9. SUFFICIENT GENERAL ILLUMINATION SHALL BE PROVIDED BY FIXED LIGHTING UNITS TO ELIMINATE, SO FAR AS POSSIBLE, THE NEED FOR PORTABLE LAMPS. WHEN PORTABLE LAMPS ARE NECESSARY, THEY SHALL BE ENCLOSED IN A MANNER APPROVED FOR CLASS 1, DIV 1 AREAS AND SHALL BE PROPERLY PROTECTED BY SUBSTANTIAL METAL OR OTHER TYPES OF GUARDS TO PREVENT BREAKAGE. SOCKETS FOR PORTABLE LAMPS SHALL BE OF THE KEYLESS MOLDED COMPOSITION TYPE WITH NO EXPOSED METAL PARTS. 10. WHEN NECESSARY TO USE PORTABLE LAMPS OR OTHER PORTABLE CURRENT CONSUMING DEVICES, FLEXIBLE CORD APPROVED FOR HARD USAGE, SUCH AS TYPE S OR TYPE PA, SHALL BE USED. SUCH A FLEXIBLE CORD SHALL CONTAIN ONE EXTRA INSULATED CONDUCTOR WHICH SHALL BE PROPERLY CONNECTED TO FORM A GROUNDING CONNECTION FOR METAL LAMP GUARDS, MOTOR FRAMES AND ALL OTHER EXPOSED METAL PORTIONS OF SUCH PORTABLE LAMPS AND DEVICES. 11. CONNECTIONS OF PORTABLE CORDS DIRECT TO SUPPLY CONDUCTORS SHALL FIRST BE MADE MECHANICALLY SECURE AND SHALL THEN BE SOLDERED AND HEAVILY TAPED. IN ADDITION, THE CORD SHALL BE SECURELY SUPPORTED SO THAT THE PROBABILITY OF A BREAK IN THE CONDUCTORS AT THIS POINT WILL BE MINIMIZED. 12. RECEPTACLES AND ATTACHMENT PLUGS, IF USED, SHALL BE SO CONNECTED AS A PART OF A UNIT DEVICE WITH AN EXPLOSION PROOF INTERLOCKING SWITCH THAT THE PLUG CANNOT BE REMOVED WHILE THE SWITCH IS IN THE "ON" POSITION, OR APPROVED DEVICES WHICH SEAL THE ARC, MADE WHEN CURRENT IS INTERRUPTED, BY MEANS OF AN EXPLOSION PROOF ENCLOSURE, SHALL BE USED. SUCH RECEPTACLES AND PLUGS SHALL BE OF THE POLARIZED TYPE PROVIDING A CONNECTION FOR THE GROUNDING WIRE OF THE PORTABLE CORD. I. SPLICES SHALL NOT BE PERMITTED IN ANY RUN OF FIXTURE HOOKUP WIRE. J. CONNECTIONS TO BRANCH CIRCUIT CONDUCTORS AND TO EXISTING FIXTURE WIRING SHALL BE MADE BY INSULATED SPRING CONNECTORS OR CRIMP TYPE CONNECTORS. K. WIRING BETWEEN FLUORESCENT LAMPHOLDERS AND ASSOCIATED OPERATING AND STARTING EQUIPMENT SHALL BE OF THE SAME OR HEAVIER GAUGE THAN THE LEADS FURNISHED WITH THE APPROVED TYPES OF BALLASTS AND SHALL HAVE EQUAL OR BETTER INSULATING AND HEAT-RESISTING CHARACTERISTICS. ALL OTHER WIRING WITHIN FLUORESCENT LIGHTING FIXTURES OR FROM A FIXTURE TO THE SPLICE WITH THE BUILDING WIRING SHALL CONFORM TO THE APPLICABLE REQUIREMENTS AND SHALL HAVE A MINIMUM OF 90 DEG. C RATED INSULATION. L. UNLESS OTHERWISE SPECIFIED OR SHOWN ON DRAWINGS, ALL WIRING IN CONJUNCTION WITH INCANDESCENT FIXTURES SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST ISSUE OF THE NATIONAL ELECTRICAL CODE AND SHALL BE NOT LESS THAN #16 AWG. WIRING SHALL BE PROTECTED WITH TAPE OR TUBING AT ALL POINTS WHERE ABRASION IS LIABLE TO OCCUR. WIRING SHALL BE CONCEALED WITHIN FIXTURE CONSTRUCTION, EXCEPT WHERE THE FIXTURE DESIGN OR MOUNTING DICTATES OTHERWISE. M. CONNECTIONS OF WIRES TO TERMINALS OF LAMPHOLDERS AND OTHER ACCESSORIES SHALL BE MADE IN A NEAT AND WORKMANLIKE MANNER AND SHALL BE ELECTRICALLY AND MECHANICALLY SECURE WITH NO LOOSE STRANDS PROTRUDING. THE NUMBER OF WIRES EXTENDING TO OR FROM THE TERMINALS OF A LAMPHOLDER SHALL NOT EXCEED THAT WHICH THE ACCESSORY IS DESIGNED TO ACCOMMODATE. N. JOINTS IN WIRING WITHIN LIGHTING FIXTURES AND CONNECTIONS OF THE FIXTURE WIRING TO THE WIRING OF THE BUILDING SHALL BE SO SPLICED THAT THEY WILL BE MECHANICALLY AND ELECTRICALLY SECURE AND THEN SOLDERED AND TAPED TO PROVIDE INSULATION EQUAL TO THAT OF THE CONDUCTORS BEING JOINED. IN LIEU OF SOLDER AND TAPE, APPROVED TYPES OF ADEQUATELY INSULATED SOLDERLESS PRESSURE CRIMPED TYPE CONNECTORS MAY BE FURNISHED, PROVIDED SIZES USED, METHOD OF APPLICATION AND TOOLS EMPLOYED ARE IN ACCORDANCE WITH THE CONNECTOR MANUFACTURER'S RECOMMENDATIONS. O. WIRING CHANNELS AND WIREWAYS SHALL BE FREE FROM PROJECTIONS AND ROUGH OR SHARP EDGED THROUGHOUT, AND ALL POINTS OR EDGES OVER WHICH CONDUCTORS MUST PASS AND MAY BE SUBJECT TO INJURY OR WEAR SHALL BE ROUNDED OR BUSHED. INSULATED BUSHINGS SHALL BE INSTALLED AT POINTS OF ENTRANCE AND EXIT OF FLEXIBLE WIRING. FLUORESCENT FIXTURES 13. THE EXPOSED NONCURRENT CARRYING METAL PARTS OF EQUIPMENT, SUCH AS THE FRAMES OR METAL EXTERIORS OF MOTORS, FIXED OR PORTABLE APPLIANCES, FIXTURES, CABINETS, CASES AND CONDUIT SHALL BE GROUNDED AS DESCRIBED ABOVE. THE LOCKNUT BUSHING AND THE DOUBLE LOCKNUT TYPE OF CONTACT SHALL NOT BE DEPENDED UPON FOR BONDING PURPOSES, BONDING JUMPERS WITH PROPER FITTINGS OR OTHER APPROVED MEANS BEING REQUIRED TO ASSURE AN EFFECTIVE GROUNDING CIRCUIT. 14. THERE SHALL BE NO EXPOSED LIVE PARTS. 23. LIGHTING FIXTURES GENERAL A. THIS CLAUSE OF THE SPECIFICATIONS COVERS THE FURNISHING OF LABOR, MATERIALS, EQUIPMENT AND THE INSTALLATION OF ALL LIGHTING FIXTURES, LIGHTING, EQUIPMENT AND LAMPS, INCLUDING THE CONNECTION OF FIXTURES AND EQUIPMENT TO THE ELECTRICAL WIRING SYSTEM AS SHOWN ON PLANS. B. THE CONTRACTOR IS DIRECTED TO REVIEW THE APPLICABLE ELECTRICAL DRAWINGS FOR DETAILS ON FIXTURE CONSTRUCTION AND INSTALLATION MEDIA FOR FIXTURES TO BE PURCHASED BY ELECTRICAL CONTRACTOR. ENGINEER STAMP: 24. EMERGENCY LIGHTING A. EXIT SIGNS PROVIDE EDGE LIT SELF-POWERED EXIT SIGNS WITH SEALED NICKEL CADMIUM BATTERY, 8" LETTERS AND COMBINATION TEST SWITCH/CHARGE MONITOR LED. UNIT SHALL BE APPROVED BY LOS ANGELES FIRE DEPARTMENT, AND MANUFACTURED IN ACCORDANCE WITH UL 924 REQUIREMENTS, ATLITE EDGE LIT SERIES OR APPROVED EQUAL, WITH RED LETTERS ON CLEAR FACE PANEL. ARROW DIRECTIONS, NUMBER OF FACES, MOUNTING METHOD AND TRIM PLATE FINISH SHALL BE AS REQUIRED FOR EACH LOCATION. EXIT SIGNS SHALL BE CONNECTED TO A SEPARATE, DEDICATED BRANCH CIRCUIT. B. BATTERY PACKS PROVIDE EMERGENCY FLUORESCENT POWER PACK UNIT WITH SEALED NICKEL CADMIUM BATTERY AND EXTERNAL TEST SWITCH AND PILOT LIGHT FOR NEW OR EXISTING FLUORESCENT FIXTURES INDICATED, UNIT SHALL BE TRILLIUM AND OWNER APPROVED, WIRED TO TWO LAMPS, LIGHT ALARMS SERIES AM10 OR APPROVED EQUAL. PROVIDE ADDITIONAL WIRING AS REQUIRED TO ENERGIZE CHARGER FROM UNSWITCHED POWER SUPPLY, PROVIDE LIGHT ALARMS SERIES AM11 OR APPROVED EQUAL EMERGENCY POWER PACK FOR COMPACT FLUORESCENT LAMPS WHERE INDICATED. LIGHTING FIXTURE HOOKUP WIRE WIRING 8. LAMPS IN FIXED POSITIONS SHALL BE ENCLOSED IN A MANNER APPROVED FOR CLASS 1, DIV 1 AREAS AND SHALL BE PROPERLY PROTECTED BY SUBSTANTIAL METAL GUARDS OR OTHER APPROVED MEANS WHERE EXPOSED TO BREAKAGE. LAMPS SHALL NOT BE OF THE PENDANT TYPE UNLESS SUPPORTED BY AND SUPPLIED THROUGH HANGERS OF RIGID CONDUIT OR FLEXIBLE CONNECTORS APPROVED FOR CLASS 1, DIV 1 AREAS. WHERE RUBBER COVERED WIRE IS USED, IT SHALL HAVE INSULATION NOT LESS THAN THREE SIXTY-FOURTHS OF AN INCH THICK. S. FIXTURES SHALL BE ATTACHED TO STRUCTURAL CEILING MEMBERS, AND SHALL NOT DEPEND UPON LATHING OR PLASTER FOR ALIGNMENT OR SUPPORT. FIXTURES IN SUSPENDED CEILINGS SHALL BE SUPPORTED BY FOUR WIRES, ONE FROM EACH CORNER TO STRUCTURE, AND SHALL BE SUPPORTED BY SADDLE HANGERS OR TIE-BARS ATTACHED TO RUNNERS OR BETWEEN CROSSBARS OF CEILING SYSTEMS. MOUNTING SPLINES OR OTHER POSITIVE MEANS OF MAINTAINING ALIGNMENT AND RIGIDITY SHALL BE PROVIDED. SUPPORTING MEMBERS SHALL BE SURFACE PASSIVATED, AND BE PRIMED OR PAINT DIPPED TO RESIST CORROSION. FASTENING DEVICES SHALL BE OF A POSITIVE LOCKING TYPE, AND SHALL NOT REQUIRE THE USE OF SPECIAL TOOLS TO REMOVE. TIE WIRES SHALL NOT BE USED IN PLACE OF FASTENING DEVICES. 25. TELEPHONE AND COMMUNICATIONS SYSTEMS A. CONTRACTOR SHALL INSTALL ALL EMPTY CONDUITS AS REQUIRED BY THE TELEPHONE COMPANY AND COMMUNICATIONS SYSTEM AND AS SHOWN IN ELECTRICAL DRAWINGS. PROVIDE A STEEL CORE NYLON ROPE DRAG LINE WITH TERMINAL BALL IN ALL EMPTY CONDUITS OVER 10' LONG. 26. INTERLOCKS A. ALL INTERLOCK WIRING SHALL BE PROVIDED UNDER THE MECHANICAL CONTRACT, INCLUDING ALL POWER TO AUTOMATIC DAMPERS, VALVES, AND ANY OTHER CONTROL EQUIPMENT SUPPORTING THE MECHANICAL SYSTEM. 27. FINAL CLEANUP AND FIELD TESTS AFTER COMPLETION OF THE ENTIRE ELECTRICAL INSTALLATION: DESCRIPTION REV DATE A. THE CONTRACTOR, BEFORE FINAL ACCEPTANCE WILL BE GRANTED, SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT AND SHALL ENSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS, ARE COMPLETED. B. THE CONTRACTOR SHALL REPAIR OR REPLACE, AS DIRECTED BY THE ENGINEER, AT NO ADDITIONAL COST TO THE OWNER, ANY ITEM DAMAGED DUE TO INSTALLATION, RELOCATION OR REINSTALLATION. C. IN ADDITION TO OTHER TESTS WHICH MAY BE REQUIRED IN THE VARIOUS OTHER DISCIPLINES, PERFORM FIELD TESTS IN THE PRESENCE OF THE ENGINEER TO DEMONSTRATE THE RELIABILITY OF THE ELECTRICAL INSTALLATION. PROVIDE THE ENGINEER WITH 48 HOURS ADVANCE NOTICE OF SUCH TESTS. AS A MINIMUM, THE FOLLOWING FIELD TESTS SHALL BE PERFORMED BY THE CONTRACTOR: 1. OPERATE ALL ELECTRICAL EQUIPMENT FOR A PERIOD OF 24 HOURS, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. 2. TEST ALL WIRES AND CABLES INSTALLED UNDER THIS CONTRACT WITH A 1,000 VOLT MEGOHMETER. FURNISH THE ENGINEER WITH A COPY OF THE RESULTS TOGETHER WITH AN OUTLINE OF THE METHOD USES. IF IN THE OPINION OF THE ENGINEER, ANY READINGS ARE LOWER THAN REQUIRED BY GOOD PRACTICE OR APPLICABLE CODES, PROMPTLY REPLACE THE MATERIALS OR EQUIPMENT INVOLVED. 3. COMPLETE SYSTEM TEST OF ALARM, SECURITY AND CONTROL SYSTEMS IN THE PRESENCE OF ALL APPROPRIATE PARTIES. SHOULD THE FOREGOING TESTS REVEAL ANY DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RE-RUN THE TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER 28. RECORD DRAWINGS PROJECT NAME: A. AS PART OF THESE REQUIREMENTS A COMPLETE SET OF "AS-BUILT" OR RECORD DRAWINGS SHALL BE PRODUCED AND DELIVERED TO TRILLIUM. P. BALLASTS SHALL PROVIDE AND ASSURE SAFE AND RELIABLE OPERATION OF THE PARTICULAR FLUORESCENT LAMP OR LAMPS SPECIFIED FOR EACH FIXTURE TYPE. BALLASTS SHALL BE ETL/CBM CERTIFIED, CLASS "P" THERMALLY PROTECTED, SUPER LOW HEAT, ELECTRONIC TYPE, ENERGY SAVING, HIGH POWER FACTOR TYPE, WITH "A" SOUND LEVEL RATING, FOR OPERATION OF RAPID START LAMPS, SERIES-SEQUENCE FOR MULTI-LAMP APPLICATIONS. B. THE DRAWINGS SHALL SHOW: 1. ALL ELECTRICAL WORK INSTALLED. 2. ALL MODIFICATIONS AND/OR ADDITIONS TO THE ORIGINAL DESIGN. 3. ALL DIMENSIONAL INFORMATION NECESSARY TO LOCATE BURIED OR CONCEALED CONDUIT WORK WHICH CANNOT BE TRACED THROUGH REGULAR MEANS OF ACCESS. Q. THE BALLASTS SHALL BE PROTECTED BY A MINIMUM OF ONE YEAR GUARANTEE STARTING FROM THE DATE OF ACCEPTANCE OF THE INSTALLED FIXTURES, AGAINST DEFECTS IN WORKMANSHIP WHICH INCLUDES AN IN-WARRANTY SERVICE PROGRAM PROVIDING FOR THE PAYMENT OF AUTHORIZED LABOR CHARGES INCURRED IN THE REPLACEMENT OF INOPERATIVE OR DEFECTIVE IN-WARRANTY BALLASTS. REPLACE BALLASTS FOUND BY ARCHITECT OR ENGINEER TO BE TOO NOISY PRIOR TO FINAL ACCEPTANCE OF JOB WITHOUT CHARGES C. THE DRAWINGS SHALL BE OF REPRODUCIBLE TYPE AND IN ELECTRONIC FORMAT, AUTOCAD 2010 OR EARLIER FORMAT. R. RECESSED FIXTURES SHALL BE FURNISHED COMPLETE WITH MOUNTING DEVICES AND ACCESSORIES. WHERE NECESSARY TO MEET CODE REQUIREMENTS, ENCLOSURE HOUSING SHALL BE SUITABLE FOR A 1 HOUR FIRE RATING. ATTACHMENT DEVICES INCLUDING BRACKETS, PLASTER RINGS, SADDLE HANGERS, AND TIE-BARS SHALL BE MADE OF FORMED OR ROLLED METAL SHAPES WITH THE REQUISITE RIGIDITY AND STRENGTH TO MAINTAIN CONTINUOUS ALIGNMENT OF THE INSTALLED FIXTURES. REVISIONS: REV NO. CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: ELECTRICAL NOTES 29. GUARANTEE A. THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF ONE YEAR FROM THE ACCEPTANCE OF THE PROJECT AGAINST DEFECTIVE MATERIALS OR WORKMANSHIP. SHEET: E-4 ENGINEER STAMP: ESD #8 ESD #9 C01 C02 C03 C07 MCC MCP MCP MCP A E-6 C04 C05 C06 C08 MCC MCP MCP MCP ESD #10 REVISIONS: REV NO. DESCRIPTION REV DATE ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 GENERAL SHEET NOTES J BARBER LEGEND 1. ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS PER NEC. 501 2. ALL UNDERGROUND CONDUITS SHALL HAVE SEAL OFFS AS THE FIRST JOINT ABOVE GROUND IN HAZARDOUS AREAS. ESD BUTTON 3. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFFS ON THE FIRST CONDUIT INTO OR OUT OF THE FIXTURE OR ENCLOSURE. WALL LIGHT 4. CONTRACTOR TO LABEL ALL PHASES AND TEST EACH PANEL TO ENSURE CONSISTENT PHASING THROUGHOUT PROJECT. CANOPY LIGHT 5. CONDUIT LOCATIONS SHOWN ARE DIAGRAMMATIC. CONDUIT LOCATIONS TO BE DETERMINED IN THE FIELD. 6. TRILLIUM WILL PROVIDE MAIN ELECTRICAL GEAR. MAIN ELECTRICAL GEAR WILL BE DELIVERED IN SECTION. SECTION WILL BE CONNECTED AND TORQUED PER MANUFACTURERS SPECIFICATIONS AND INSTALLED BY CONTRACTOR. 7. CONTRACTOR TO PROVIDE WIRE MARKERS ON EACH END OF EACH WIRE. WIRE NUMBERS WILL BE MARKED ON AS-BUILT SET OF DRAWINGS BY CONTRACTOR. 8. FLEXIBLE METAL CONDUIT IS NOT PERMITTED IN CLASS 1 DIVISION 1 AREAS (CLASS 1 DIV 1). THIS INCLUDES PIT CONDUITS FOR DISPENSER ELECTRICAL RUNS. # ESD BUTTON # PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: ELECTRICAL CONDUIT LAYOUT CEILING LIGHT PHOTO CELL CCTV CAMERA SHEET: E-5 ENGINEER STAMP: MCP C54 C46 MCC BRKR C19 C20 MCC C22 C53 #20 3$ C23 MCC PHONE COMPANY REVISIONS: REV NO. DESCRIPTION REV DATE C50 MCC MCP C59 MCC MCC C49 C52 MCC C52 TRANSFORMER C21 MCP C47 MCC MCC C48 3$ #11 MCC C50 MCC C50 ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 MCP MCC CHECKS: GENERAL SHEET NOTES C42 C43 1. ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS PER NEC. 501 2. ALL UNDERGROUND CONDUITS SHALL HAVE SEAL OFFS AS THE FIRST JOINT ABOVE GROUND IN HAZARDOUS AREAS. 3. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFFS ON THE FIRST CONDUIT INTO OR OUT OF THE FIXTURE OR ENCLOSURE. 4. CONTRACTOR TO LABEL ALL PHASES AND TEST EACH PANEL TO ENSURE CONSISTENT PHASING THROUGHOUT PROJECT. 5. CONDUIT LOCATIONS SHOWN ARE DIAGRAMMATIC. CONDUIT LOCATIONS TO BE DETERMINED IN THE FIELD. 6. TRILLIUM WILL PROVIDE MAIN ELECTRICAL GEAR. MAIN ELECTRICAL GEAR WILL BE DELIVERED IN SECTION. SECTION WILL BE CONNECTED AND TORQUED PER MANUFACTURERS SPECIFICATIONS AND INSTALLED BY CONTRACTOR. 7. 8. 0' 2' 4' 6' 8' 10' CONTRACTOR TO PROVIDE WIRE MARKERS ON EACH END OF EACH WIRE. WIRE NUMBERS WILL BE MARKED ON AS-BUILT SET OF DRAWINGS BY CONTRACTOR. FLEXIBLE METAL CONDUIT IS NOT PERMITTED IN CLASS 1 DIVISION 1 AREAS (CLASS 1 DIV 1). THIS INCLUDES PIT CONDUITS FOR DISPENSER ELECTRICAL RUNS. C COGGINS 2015-01-21 J BARBER LEGEND # ESD BUTTON # ESD BUTTON WALL LIGHT CANOPY LIGHT PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: ELECTRICAL CONDUIT LAYOUT CEILING LIGHT PHOTO CELL CCTV CAMERA SHEET: E-6 LEGEND GENERAL SHEET NOTES MCC - MOTOR CONTROL CENTER (POWER) MCP - MASTER CONTROL PANEL (CONTROL) TWSP - TWISTED SHIELDED PAIR 1. COLORS OF WIRE ARE SHOWN IN ON E-3 ON NOTE 16A. 2. FLEXIBLE METAL CONDUIT IS NOT PERMITTED IN CLASS 1 DIVISION 1 AREAS (CLASS 1 DIV 1). THIS INCLUDES PIT CONDUITS FOR DISPENSER ELECTRICAL RUNS. ENGINEER STAMP: EQUIPMENT NOTES 1. ESD BUTTONS: SHALL BE EATON 10250T7007 W/ 10250TA56 SHROUD 2. PURGE BLOWER: FANTECH FKD-BXL W/ WC15 CONTROLLER 3. ELECTRICAL ROOM CEILING LIGHTS: LITHONIA STL4 48L D50 LP835 NX 4. EQUIPMENT AREA LIGHTS: DIALIGHT SAFESITE WPC2C3LNLGC LED CLASS 1 DIV 2-RATED 120V/34W WALLPACKS W/ APPROPRIATE MOUNTING FIXTURES CONDUIT INSTALLED BY OTHERS. WIRES TO BE PULLED BY CONTRACTOR CA MARINA MRWMD - ELECTRICAL CONDUIT SCHEDULE MARK SIZE QTY C01 1" 1 DISPENSER 1 POWER (4) #12 AWG THWN C02 1" 1 DISPENSER 1 CONTROL C03 1" 1 C04 1" C05 DESCRIPTION WIRE COLOR SEE GENERAL SHEET NOTE 1 FROM TO NOTES MCC DISPENSER 1 (4) #18 TWSP MCP DISPENSER 1 DISPENSER 1 SPARE PULL ROPE MCP DISPENSER 1 1 DISPENSER 2 POWER (4) #12 AWG THWN MCC DISPENSER 2 1" 1 DISPENSER 2 CONTROL (4) #18 TWSP MCP DISPENSER 2 C06 1" 1 DISPENSER 2 SPARE PULL ROPE MCP DISPENSER 2 C07 3/4" 1 DISPENSER 1 ESD #1 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP DISPENSER 1 ESD #1 SEE EQUIPMENT NOTE 1 C08 3/4" 1 DISPENSER 2 ESD #2 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP DISPENSER 2 ESD #2 SEE EQUIPMENT NOTE 1 C09 3/4" 1 DE-FUEL PANEL POWER (12) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP DE-FUEL PANEL C10 3/4" 1 DE-FUEL PANEL CONTROL (2) CAT 5e MCP DE-FUEL PANEL TWSP TO BE OMNI CABLE DS 11802 C11 3/4" 1 ZONE 1: ESD #3 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ZONE 1 ESD BUTTON #3 SEE EQUIPMENT NOTE 1 C12 3/4" 1 ZONE 1: ESD #3 TO ESD #4 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 ESD BUTTON #3 ZONE 1 ESD BUTTON #4 SEE EQUIPMENT NOTE 1 C13 3/4" 1 ZONE 1: ESD #4 TO ESD #5 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 ESD BUTTON #4 ZONE 1 ESD BUTTON #5 SEE EQUIPMENT NOTE 1 C14 3/4" 1 ZONE1: ESD #5 TO ESD #6 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 ESD BUTTON #5 ZONE 1 ESD BUTTON #6 SEE EQUIPMENT NOTE 1 C15 3/4" 1 ZONE 1: ESD #6 TO ESD #7 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 ESD BUTTON #6 ZONE 1 ESD BUTTON #7 SEE EQUIPMENT NOTE 1 C16 3/4" 1 ZONE 2 : ESD #8 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ZONE 2 ESD BUTTON #8 SEE EQUIPMENT NOTE 1 C17 3/4" 1 ZONE 2: ESD #8 TO ESD #9 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 ESD BUTTON #8 ZONE 2 ESD BUTTON #9 SEE EQUIPMENT NOTE 1 C18 3/4" 1 ZONE 2: ESD #9 TO EDS #10 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 ESD BUTTON #9 ZONE 2 ESD BUTTON #10 SEE EQUIPMENT NOTE 1 C19 4" 4 POWER FROM TRANSFORMER (3) 600 MCM THWN, (1) 600 MCM THWN GND SEE GENERAL SHEET NOTE 1 TRANSFORMER MAIN BREAKER CONDUITS AND WIRE SUPPLIED BY OTHERS C20 4" 4 MOTOR CONTROL CENTER - POWER (3) 600 MCM THWN, (1) 600 MCM THWN GND SEE GENERAL SHEET NOTE 1 MAIN BREAKER MOTOR CONTROL CENTER (MCC) C21 N/A 1 MASTER CONTROL PANEL - POWER (6) #10 AWG THWN SEE GENERAL SHEET NOTE 1 MCC MASTER CONTROL PANEL (MCP) WIRES TO BE PULLED THROUGH ELECTRICAL GUTTER C22 N/A 1 MOTOR CONTROL PANEL - I/O CONTROLS (2) #14 AWG THWN, (2) CAT 5e SEE GENERAL SHEET NOTE 1 MCP MCC WIRES TO BE PULLED THROUGH ELECTRICAL GUTTER C23 N/A 1 COMMUNICATIONS (4) CAT 5e MCP PHONE COMPANY TERMINATION POINT TBD C24 1-1/2" 1 480 VAC TO 480-120/208 XFMR (4) #1 AWG THWN, (1) #6 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC 480-120/208 XFMR C25 1-1/2" 1 120 VAC XFMR TO L1 & LS2 BREAKER (3) #1 AWG THWN, (1) #2 AWG THWN GND SEE GENERAL SHEET NOTE 1 480-120/208 XFMR MCC C26 3" 1 COMPRESSOR A POWER (6) 3/0 MCM THWN, (1) #3 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC SKID A MOTOR ANGI CONDUIT CONNECTION C4 C27 1" 1 COMPRESSOR A PRELUBE, COOLER & HEATER (9) #10 AWG THWN, (3) #10 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC SKID A POWER BOX ANGI CONDUIT CONNECTION C3 C28 1" 1 COMPRESSOR A 120V POWER (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC SKID A POWER BOX ANGI CONDUIT CONNECTION C2 C29 1" 1 COMPRESSOR A CONTROL (2) CAT 5e MCP SKID A POWER BOX ANGI CONDUIT CONNECTION C1 C30 3" 1 COMPRESSOR B POWER (6) 3/0 MCM THWN, (1) #3 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC SKID B MOTOR ANGI CONDUIT CONNECTION C4 C31 1" 1 COMPRESSOR B PRELUBE, COOLER & HEATER (9) #10 AWG THWN, (3) #10 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC SKID B POWER BOX ANGI CONDUIT CONNECTION C3 C32 1" 1 COMPRESSOR B 120V POWER (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC SKID B POWER BOX ANGI CONDUIT CONNECTION C2 C33 1" 1 COMPRESSOR B CONTROL (2) CAT 5e MCP SKID B POWER BOX ANGI CONDUIT CONNECTION C1 C34 3" 1 COMPRESSOR C POWER (6) 3/0 MCM THWN, (1) #3 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC SKID C MOTOR ANGI CONDUIT CONNECTION C4 C35 1" 1 COMPRESSOR C PRELUBE, COOLER & HEATER (9) #10 AWG THWN, (3) #10 AWG THWN GND SEE GENERAL SHEET NOTE 1 MCC SKID C POWER BOX ANGI CONDUIT CONNECTION C3 C36 1" 1 COMPRESSOR C 120V POWER (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC SKID C POWER BOX ANGI CONDUIT CONNECTION C2 C37 1" 1 COMPRESSOR C CONTROL (2) CAT 5e MCP SKID C POWER BOX ANGI CONDUIT CONNECTION C1 C38 3" 1 FUTURE COMPRESSOR D POWER PULL ROPE SEE NOTE 16 ON PAGE E-3 MCC SKID D MOTOR ANGI CONDUIT CONNECTION C4 C39 1" 1 FUTURE COMPRESSOR D PRELUBE, COOLER & HEATER PULL ROPE SEE NOTE 16 ON PAGE E-3 MCC SKID D POWER BOX ANGI CONDUIT CONNECTION C3 C40 1" 1 FUTURE COMPRESSOR D 120V POWER PULL ROPE SEE NOTE 16 ON PAGE E-3 MCC SKID D POWER BOX ANGI CONDUIT CONNECTION C2 C41 1" 1 FUTURE COMPRESSOR D CONTROL PULL ROPE MCP SKID D POWER BOX ANGI CONDUIT CONNECTION C1 C42 2" 1 GAS DRYER POWER (3) #6 AWG THWN, (1) #10 AWG THWN GND MCC GAS DRYER C43 1" 1 GAS DRYER CONTROL (2) CAT 5e MCP GAS DRYER C44 3/4" 1 VALVE PANEL 120V CONTROL (6) #18 TWSP, (12) #12 AWG THWN MCP VALVE PANEL C45 3/4" 1 VALVE PANEL SPARE PULL ROPE MCP VALVE PANEL C46 3/4" 1 AIR COMPRESSOR POWER (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC AIR COMPRESSOR C47 3/4" 1 AIR DRYER POWER (3) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC AIR DRYER C48 3/4" 1 PURGE BLOWER POWER (3) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC PURGE BLOWER SEE EQUIPMENT NOTE 2 C49 1" 1 ELECTRICAL ROOM CEILING LIGHTS (3) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC ELECTRICAL ROOM LIGHTS SEE EQUIPMENT NOTE 3 C50 1" 1 EQUIPMENT AREA C1D2 AREA LIGHTS (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC EQUIPMENT AREA LIGHTS SEE EQUIPMENT NOTE 4 C51 1" 1 PHOTOCELL (3) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC PHOTOCELL C52 1" 1 CONTROL ROOM 120V OUTLETS (3) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC 120V OUTLETS 120V GFCI OUTLETS C53 1" 1 208V OUTLET FOR HVAC (3) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCC 208V OUTLET 208V 20A PLUG OUTLET FOR HVAC C54 3/4" 1 EQUIPMENT AREA ESD BUTTON #11 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ESD BUTTON #11 SEE EQUIPMENT NOTE 1 C55 3/4" 1 EQUIPMENT AREA ESD BUTTON #12 & #13 (6) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ESD BUTTONS #12 & #13 SEE EQUIPMENT NOTE 1 C56 3/4" 1 EQUIPMENT AREA ESD BUTTON #14 & #15 (6) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ESD BUTTONS #14 & #15 SEE EQUIPMENT NOTE 1 C57 3/4" 1 EQUIPMENT AREA ESD BUTTON #16 & #17 (6) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ESD BUTTONS #16 & #17 SEE EQUIPMENT NOTE 1 C58 3/4" 1 EQUIPMENT AREA ESD BUTTON #18 & #19 (6) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ESD BUTTONS #18 & #19 SEE EQUIPMENT NOTE 1 C59 3/4" 1 EQUIPMENT AREA ESD BUTTON #20 (4) #12 AWG THWN SEE GENERAL SHEET NOTE 1 MCP ESD BUTTON #20 SEE EQUIPMENT NOTE 1 SEE GENERAL SHEET NOTE 1 SEE GENERAL SHEET NOTE 1 SEE GENERAL SHEET NOTE 1 TWSP TO BE OMNI CABLE DS 11802 TWSP TO BE OMNI CABLE DS 11802 TWSP TO BE OMNI CABLE DS 11802 REVISIONS: REV NO. DESCRIPTION REV DATE ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: CONDUIT SCHEDULE SHEET: E-7 GENERAL SHEET NOTES SHEET KEYNOTES 1. 120/208V 100A 24 CIRCUIT PANEL. 2. CONTACTOR TO BE WIRED TO ESD CIRCUIT. 3. 1. PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT LOCATED OUTDOORS. REFER TO PLANS FOR EQUIPMENT LOCATIONS. 2. REFER TO PLANS FOR CONSTRAINTS ON PHYSICAL DIMENSIONS AND CLEARANCE REQUIREMENTS OF EQUIPMENT. PROVIDE EQUIPMENT DIMENSIONS THAT FALL WITHIN THE CONSTRAINTS OF EACH SPECIFIC LOCATION. 3. ALL EQUIPMENT SHALL BE CONSTRUCTED AND BRACED FOR THE SEISMIC CONDITIONS OF THE PROJECT. REFER TO SPECIFICATIONS FOR REQUIREMENTS. TRANSFORMER TO BE PROVIDED BY OTHERS. ENGINEER STAMP: 4. NEMA 3R SERVICE ENTRANCE RATED GEAR. 5. NEMA 3R GEAR. 6. CUTLER-HAMMER TYPE SERIES C, TYPE NW/HNW/NWC CIRCUIT BREAKER WITH ELECTRONIC SHORT DELAY PICKUP AND TIME TRIP UNIT. 7. CIRCUIT BREAKER TO PROVIDE GROUND FAULT PROTECTION. 8. CIRCUIT BREAKER IS OPTIONAL IF SERVICE ENTRANCE BREAKER IS IN LINE OF SITE OF MCC. REPLACE WITH A DISCONNECT. 4. CONTRACTOR TO LABEL ALL PHASES AND TEST EACH PANEL TO ENSURE CONSISTENT PHASING THROUGHOUT PROJECT. 5. ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS AS PER NEC 501. ALL UNDER GROUND CONDUITS SHALL HAVE A SEAL OFF AS THE FIRST JOINT ABOVE GROUND. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFF ON FIRST CONDUIT INTO OR OUT OF THE FIXTURE OF ENCLOSURE. 6. SEE SHEET E-5, E-6, & E-7 FOR CONDUIT AND CONDUCTOR SCHEDULE. REVISIONS: REV NO. DESCRIPTION REV DATE ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: ELECTRICAL ONE LINE DIAGRAM SHEET: E-8 5 GENERAL SHEET NOTES 5'-0" VENT STACK DISCHARGE 2 1. ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS PER NEC. 501. 2. ALL UNDERGROUND CONDUITS SHALL HAVE SEAL OFFS AS THE FIRST JOINT ABOVE GROUND IN HAZARDOUS AREAS. 3. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFFS ON FIRST CONDUIT INTO OR OUT OF THE FIXTURE OF ENCLOSURE. 4. FORM 5 LB FITTINGS ALLOWED TO BE USED IN C1D2 AREAS WHERE IT IS USED AS A PULL BOX FOR WIRE. SEAL OFFS ARE REQUIRED AT STUB UP AREAS AND BEFORE ENTERING WIRE TERMINATION DEVICE. 5. HAZARDOUS AREAS SHOWN PER NFPA 52-2013 TABLE 7.4.2.9 ELECTRICAL INSTALLATIONS. 6. INSIDE COMPRESSOR ENCLOSURES DEFINED AS CLASS 1 DIVISION 2 PER NFPA 52-2013. 5'-0" 15'-0" 2 5'-0" 10'-0" MIN. 5 5'-0" COMPRESSED NATURAL GAS (CNG) DISPENSER 1 ENGINEER STAMP: 2 5' -0 " COMPRESSED NATURAL GAS (CNG) VENT STACK HAZARDOUS LOCATION AROUND FUEL DISPENSERS (TYPICAL) VENT STACK DISCHARGE 2 1 R5 '-0 " R15'-0" HAZARDOUS LOCATION AROUND VENT STACK (TYPICAL) SHEET KEY NOTES 1 2 3 4 5 NEC CLASS 1 DIVISION 1 HAZARDOUS AREA NEC CLASS 1 DIVISION 2 HAZARDOUS AREA NFPA 52 - NEC CLASS 1 DIVISION 2 (LOCATED INSIDE COMPRESSORS) VENTED ABOVE DISPENSER NFPA 52 - NEC CLASS 1 DIVISION 1 (LOCATED INSIDE DISPENSER ENCLOSURE) REVISIONS: REV NO. DESCRIPTION REV DATE FUTURE TIME FILL ZONE 3 ADDRESS: B E-10 FUTURE TIME FILL ZONE 3 C DE-FUEL PANEL AREA E-8 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: A E-10 TIME FILL ZONE 2 C COGGINS 2015-01-21 TIME FILL ZONE 1 B E-10 J BARBER B E-10 B E-10 PROJECT NAME: C E-10 FUTURE TIME FILL ZONE 4 B E-10 CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: HAZARDOUS AREA SHEET: E-9 5 5'-0" VENT STACK DISCHARGE 2 1. ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS PER NEC. 501. 2. ALL UNDERGROUND CONDUITS SHALL HAVE SEAL OFFS AS THE FIRST JOINT ABOVE GROUND IN HAZARDOUS AREAS. 3. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFFS ON FIRST CONDUIT INTO OR OUT OF THE FIXTURE OF ENCLOSURE. 4. FORM 5 LB FITTINGS ALLOWED TO BE USED IN C1D2 AREAS WHERE IT IS USED AS A PULL BOX FOR WIRE. SEAL OFFS ARE REQUIRED AT STUB UP AREAS AND BEFORE ENTERING WIRE TERMINATION DEVICE. 5. HAZARDOUS AREAS SHOWN PER NFPA 52-2013 TABLE 7.4.2.9 ELECTRICAL INSTALLATIONS. 6. INSIDE COMPRESSOR ENCLOSURES DEFINED AS CLASS 1 DIVISION 2 PER NFPA 52-2013. 5'-0" 15'-0" 2 GENERAL SHEET NOTES 5'-0" 1 10'-0" MIN. 5 5'-0" COMPRESSED NATURAL GAS (CNG) DISPENSER 2 ENGINEER STAMP: -0 5' " COMPRESSED NATURAL GAS (CNG) VENT STACK HAZARDOUS LOCATION AROUND FUEL DISPENSERS (TYPICAL) VENT STACK DISCHARGE 2 1 R5 R15'-0" '-0 " SHEET KEY NOTES HAZARDOUS LOCATION AROUND VENT STACK (TYPICAL) 1 2 3 4 5 NEC CLASS 1 DIVISION 1 HAZARDOUS AREA NEC CLASS 1 DIVISION 2 HAZARDOUS AREA NFPA 52 - NEC CLASS 1 DIVISION 2 (LOCATED INSIDE COMPRESSORS) VENTED ABOVE DISPENSER NFPA 52 - NEC CLASS 1 DIVISION 1 (LOCATED INSIDE DISPENSER ENCLOSURE) REVISIONS: HAZARD ZONE DIRECTLY AROUND DISPENSER REV NO. DESCRIPTION REV DATE HAZARD ZONE AT DISPENSER VENT 5 2 ADDRESS: 2 4 14207 DEL MONTE BLVD MONTEREY, CA 93933 2 CHECKS: C COGGINS 2015-01-21 J BARBER HAZARD ZONE DIRECTLY AROUND DISPENSER 1 4 PROJECT NAME: HAZARD ZONE AT DISPENSER VENT CA MARINA MRWMD CNG FUELING STATION 5 DRAWING NAME: HAZARDOUS AREA 2 2 4 SHEET: B TIME FILL AREA E-10 A FAST FILL AREA E-10 C EQUIPMENT AREA E-10 E-10 5 5'-0" VENT STACK DISCHARGE GENERAL SHEET NOTES 1. ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS PER NEC. 501. 2. ALL UNDERGROUND CONDUITS SHALL HAVE SEAL OFFS AS THE FIRST JOINT ABOVE GROUND IN HAZARDOUS AREAS. 3. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFFS ON FIRST CONDUIT INTO OR OUT OF THE FIXTURE OF ENCLOSURE. 4. FORM 5 LB FITTINGS ALLOWED TO BE USED IN C1D2 AREAS WHERE IT IS USED AS A PULL BOX FOR WIRE. SEAL OFFS ARE REQUIRED AT STUB UP AREAS AND BEFORE ENTERING WIRE TERMINATION DEVICE. 5. HAZARDOUS AREAS SHOWN PER NFPA 52-2013 TABLE 7.4.2.9 ELECTRICAL INSTALLATIONS. 6. INSIDE COMPRESSOR ENCLOSURES DEFINED AS CLASS 1 DIVISION 2 PER NFPA 52-2013. 5'-0" 15'-0" 2 2 5'-0" ENGINEER STAMP: 1 10'-0" MIN. 5 5'-0" COMPRESSED NATURAL GAS (CNG) DISPENSER 2 5' -0 " COMPRESSED NATURAL GAS (CNG) VENT STACK HAZARDOUS LOCATION AROUND FUEL DISPENSERS (TYPICAL) VENT STACK DISCHARGE 2 R15'-0" " HAZARDOUS LOCATION AROUND VENT STACK (TYPICAL) SHEET KEY NOTES 1 2 3 4 5 NEC CLASS 1 DIVISION 1 HAZARDOUS AREA NEC CLASS 1 DIVISION 2 HAZARDOUS AREA NFPA 52 - NEC CLASS 1 DIVISION 2 (LOCATED INSIDE COMPRESSORS) VENTED ABOVE DISPENSER NFPA 52 - NEC CLASS 1 DIVISION 1 (LOCATED INSIDE DISPENSER ENCLOSURE) REVISIONS: 1 REV NO. DESCRIPTION REV DATE 1 2 2 ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 1 1" SS TUBE VENT MINIMUM 10' ABOVE GRADE 1 CHECKS: VENT SUPPORT C COGGINS 5'-3" 2015-01-21 J BARBER 2 2 8'-10" R5 '-0 10'-0" MIN. 1 5 PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: HAZARDOUS AREA A SLOW FILL POST HAZARD ZONE E-5 B DISPENSER HAZARD ZONE E-11 SHEET: E-11 ENGINEER STAMP: EXISTING GROUNDING STUBBED UP IN ELECTRICAL VAULT FOR FUTURE TIME FILL BANK NEW TIME FILL POST TO CONNECT TO EXISTING GROUNDING TYP. FOR ALL POST G EXISTING E-14 J TYP. FOR ALL E-14 TIME FILL POST J TYP. FOR ALL E-14 TIME FILL POST G EXISTING E-14 J TYP. FOR ALL E-14 TIME FILL POST NEW FAST FILL DISPENSER TO CONNECT TO EXISTING GROUNDING G EXISTING E-14 N E-14 NEW DE-FUEL PANEL TO CONNECT TO EXISTING GROUNDING CABLE EXISTING GROUNDING EXISTING GROUNDING J TYP. FOR ALL E-14 TIME FILL POST EXISTING GROUNDING EXISTING GROUNDING NEW TIME FILL POST TO CONNECT TO EXISTING GROUNDING TYP. FOR ALL POST EXISTING GROUNDING TO CONNECT TO NEW GROUNDING E E-14 G EXISTING E-14 REVISIONS: REV NO. DESCRIPTION REV DATE A E-13 NEW GROUNDING AREA E E-14 GENERAL SHEET NOTES 1. ALL COPPER BELOW GRADE 3/0 MINIMUM, CONTRACTOR MAY USE LARGER. 2. ALL COPPER ABOVE GRADE 2/0. 3. ALL INTERSECTIONS TO BE BONDED. 4. ALL 2/0 COPPER COMING ABOVE GRADE MUST BE LONG ENOUGH TO TIE TO EACH SPECIFIC PIECE OF EQUIPMENT. 5. EACH STRUCTURE TO BE GROUNDED ON TWO SIDES USING COMPRESSION TWO HOLE SPADE. 6. ALL FUTURE COPPER MUST BE COILED AND PLACED ON PAD MAKING SURE SUFFICIENT LENGTHS REMAIN, TO CONNECT TO EQUIPMENT. NEW FAST FILL DISPENSER TO CONNECT TO EXISTING GROUNDING EXISTING GROUNDING STUBBED UP IN ELECTRICAL VAULT FOR FUTURE TIME FILL BANK ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 7. REFER TO GROUNDING DETAIL DRAWING E-10 FOR ASSEMBLY DETAILS. J BARBER 8. SAWCUT, PATCH AND REPAIR PARKING LOT SURFACE AS NECESSARY. 9. THE CONTRACTOR SHALL BE REQUIRED TO COMPACT THE TRENCHES USING SPECIFIC EQUIPMENT THAT CAN COMPACT THE NARROW TRENCHES AND ACHIEVE A MINIMUM OF 95 PERCENT RELATIVE COMPACTION PER ASTM D-1557. JETTING IS NOT ALLOWED. THE TRENCH BACKFILL SHALL BE PLACED IN THIN LIFTS NOT TO EXCEED 4 INCHES IN THICKNESS IN THE NARROW TRENCHES. THE MOISTURE CONTENT SHALL RANGE FROM OPTIMUM TO 3 PERCENT ABOVE OPTIMUM MOISTURE CONTENT AT TIME PLACEMENT. THE BACKFILL MATERIAL SHALL CONFORM WITH THE ENGINEERED FILL REQUIREMENTS IN THE PROJECT GEOTECHNICAL ENGINEERING REPORT, THE REQUIREMENTS OF THE PIPE MANUFACTURER, AND THE PROJECT SPECIFICATIONS, WHICHEVER IS MORE STRINGENT. PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: 10. GROUND GRID CONDUCTORS SHALL BE BURIED A MINIMUM OF 1'-6" BELOW FINAL EARTH GRADE. GROUNDING LAYOUT 11. GROUND RODS SHOULD BE INSTALLED WITH TOPS 1'-0" MINIMUM BELOW GRADE AND BONDED TO THE GROUND GRID CONDUCTORS. 12. REFER TO SPECIFICATIONS FOR INSTALLATION AND MATERIAL REQUIREMENTS. 13. ALL BENDS SHOWN SHALL BE 4" MINIMUM RADIUS. 14. CONTRACTOR TO RECORD CONDUCTOR LAYOUT ON AS BUILT DRAWINGS. 15. GROUNDING IN FUEL DISPENSER AREA RUN OVERHEAD IN CONDUIT FROM FUEL BUILDING PULL BOX TO FUEL DISPENSERS. SHEET: E-12 ZO NE S ENGINEER STAMP: M E FI LL STUB UP FOR EXISTING GROUNDING UN DI N G TO TI R E-14 O E-14 O E-14 EX IS T IN G GR O P E-14 H E-14 A E-14 C E-14 I E-14 EXISTING GROUNDING TO FAST FILL DISPENSERS C E-14 Q E-14 L E-14 B E-14 G E-14 B E-14 F E-14 C E-14 A E-14 G E-14 H E-14 P E-14 REVISIONS: F E-14 O E-14 H E-14 GENERAL SHEET NOTES 1. ALL COPPER BELOW GRADE 2/0 MINIMUM, CONTRACTOR MAY USE LARGER. 2. ALL COPPER ABOVE GRADE 2/0. 3. ALL INTERSECTIONS TO BE BONDED. 4. ALL 2/0 COPPER COMING ABOVE GRADE MUST BE LONG ENOUGH TO TIE TO EACH SPECIFIC PIECE OF EQUIPMENT. 5. EACH STRUCTURE TO BE GROUNDED ON TWO SIDES USING COMPRESSION TWO HOLE SPADE. 6. REFER TO GROUNDING DETAIL DRAWING E-10 FOR ASSEMBLY DETAILS. 8. SAWCUT, PATCH AND REPAIR PARKING LOT SURFACE AS NECESSARY. 9. THE CONTRACTOR SHALL BE REQUIRED TO COMPACT THE TRENCHES USING SPECIFIC EQUIPMENT THAT CAN COMPACT THE NARROW TRENCHES AND ACHIEVE A MINIMUM OF 95 PERCENT RELATIVE COMPACTION PER ASTM D-1557. JETTING IS NOT ALLOWED. THE TRENCH BACKFILL SHALL BE PLACED IN THIN LIFTS NOT TO EXCEED 4 INCHES IN THICKNESS IN THE NARROW TRENCHES. THE MOISTURE CONTENT SHALL RANGE FROM OPTIMUM TO 3 PERCENT ABOVE OPTIMUM MOISTURE CONTENT AT TIME PLACEMENT. THE BACKFILL MATERIAL SHALL CONFORM WITH THE ENGINEERED FILL REQUIREMENTS IN THE PROJECT GEOTECHNICAL ENGINEERING REPORT, THE REQUIREMENTS OF THE PIPE MANUFACTURER, AND THE PROJECT SPECIFICATIONS, WHICHEVER IS MORE STRINGENT. DESCRIPTION REV DATE 1 UPDATED CALLOUTS TO 'E-14' 04/15/15 F E-14 A E-14 F E-14 ADDRESS: F E-14 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: A E-14 ALL FUTURE COPPER MUST BE COILED AND PLACED ON PAD MAKING SURE SUFFICIENT LENGTHS REMAIN, TO CONNECT TO EQUIPMENT. 7. REV NO. C COGGINS 2015-01-21 J BARBER H E-14 F E-14 PROJECT NAME: G E-14 CA MARINA MRWMD CNG FUELING STATION F E-14 F E-14 DRAWING NAME: 10. GROUND GRID CONDUCTORS SHALL BE BURIED A MINIMUM OF 1'-6" BELOW FINAL EARTH GRADE. 11. GROUND RODS SHOULD BE INSTALLED WITH TOPS 1'-0" MINIMUM BELOW GRADE AND BONDED TO THE GROUND GRID CONDUCTORS. 12. REFER TO SPECIFICATIONS FOR INSTALLATION AND MATERIAL REQUIREMENTS. GROUNDING LAYOUT F E-14 O E-14 SHEET: 13. ALL BENDS SHOWN SHALL BE 4" MINIMUM RADIUS. 14. CONTRACTOR TO RECORD CONDUCTOR LAYOUT ON AS BUILT DRAWINGS. 15. GROUNDING IN FUEL DISPENSER AREA RUN OVERHEAD IN CONDUIT FROM FUEL BUILDING PULL BOX TO FUEL DISPENSERS. 0' 2' 4' 6' 8' 10' E-13 ENGINEER STAMP: STORAGE VESSELS AIR COMPRESSOR TRAFFIC RATED HANDHOLD MOUNTED FLUSH WITH GRADE FELT PAD EXISTING STUB UP REVISIONS: REV NO. DESCRIPTION REV DATE DE-FUEL PANEL MCC CABINET GROUND BUS INSIDE MCC BACK PANEL TRENCH TO BE MOUNTED TO BACK PANEL ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER VENT STACK VALVE PANEL PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: GROUNDING DETAILS SHEET: E-14 ENGINEER STAMP: CA Marina MRWMD - MCC VOLTS/PHASE/WIRE: MAIN SIZE & TYPE: LOCATION: 480 V, 3 PH 3 WIRE 1600 AMP GFI CB IN MCC MCC PANEL "HS1" NOT AN ACTUAL PANEL. FOR LOAD TRACKING ONLY. NOTES: ACCESSORIES: IDENTIFICATION, GROUNDING BAR, INSULATED GROUND BAR CKT LOAD (kVA) OCP LTG CO PANEL / EQUIPMENT PWR LCL AMP POLE 1 400 3 66.5 - - - 66.5 66.5 - - - 66.5 66.5 3 400 3 66.5 - - - 66.5 66.5 - - - 66.5 66.5 5 400 3 66.5 - - - 66.5 - - - 66.5 400 3 66.5 - - - 66.5 - - - 66.5 PANEL SIZE & TYPE: MAIN SIZE & TYPE: LOCATION: CABINET: 100 AMPERE BREAKER 100 AMPERE TERMINAL MCC NEMA 3R SKID A COMPRESSOR SKID B COMPRESSOR SKID C COMPRESSOR PHASE LOAD kVA A 66.5 75.1 66.5 66.5 B 74.2 72.3 77.6 78.2 78.2 77.6 77.6 66.5 (F) SKID D COMPRESSOR 66.5 kVA 77.6 66.5 66.5 PWR AMP POLE NO NO AMP POLE LTG CO DESCRIPTION LCL PWR 7.8 0.5 1.0 7.2 50 3 2 1 20 3 3.9 SKID A COOLER 3.9 2.0 0.0 5.8 - - - - - - 3.9 - 3.9 6.3 - 2.0 1.0 2.8 - - - - - - 3.9 - 3.9 11.2 BREAKER HS1 0.0 0.0 11.2 100 3 4 3 15 3 0.3 SKID A PRELUBE 0.3 11.7 0.0 0.0 11.7 - - - - - - 0.3 - 0.3 11.7 0.0 0.0 11.7 - - - - - - 0.3 - 0.3 11.1 60 3 6 5 15 3 0.3 SKID A HEATER 0.3 11.1 - - - - - - 0.3 - 0.3 11.1 - - 11.1 SPACE 0.0 - - - - 0.3 - 0.3 8 7 20 3 3.9 SKID B COOLER 3.9 - - - - 3.9 - 3.9 - - - 3.9 - 3.9 CONNECTED kVA PER PHASE 297 296 295 CONNECTED TOTAL kVA 888 9 15 3 0.3 SKID B PRELUBE 0.3 CONNECTED AMPS PER PHASE 1072 1070 1063 CONNECTED AVERAGE AMPS PER PHASE 1069 - - - 0.3 - 0.3 TOTALS: - (F) = FUTURE - - - 0.3 - 0.3 LIGHTING 4.5kVA @125% = 5.6 kVA ALL OTHER LOADS @100% = 881.3 kVA DIVERSIFIED TOTAL kVA = 939 11 15 3 0.3 SKID B HEATER 0.3 RECEPTACLES 2kVA @100% = 2.0 kVA 25% OF LARGEST MOTOR = 49.9 kVA AVERAGE AMPS PER PHASE = 1129 - - - 0.3 - 0.3 REMAINDER 0kVA @ 50% = 0.0 kVA - - - 0.3 - 0.3 13 15 3 2.1 AIR COMPRESSOR 2.1 - - - 2.1 - 2.1 - - - 2.1 - 2.1 NEC DIVERSIFIED LOAD CALCULATIONS LOAD (kVA) OCP PANEL SIZE & TYPE: MAIN SIZE & TYPE: LOCATION: CABINET: 100 AMP PANEL 50 AMP BREAKER MCC NEMA 3R NO AMP POLE 1 20 1 LTG CO DESCRIPTION LCL PWR 1.2 PHASE LOAD kVA A MCP SPARE 1.2 2.4 3 20 1 1.5 EQUIPMENT AREA LIGHTS 1.9 5 20 1 1.0 ELECTRICAL ROOM LIGHTS 1.3 7 20 1 0.5 SPARE 0.5 9 20 1 0.5 SPARE 0.5 11 20 1 0.5 SPARE 0.5 13 SPACE 0.0 15 SPACE 0.0 17 SPACE 0.0 19 SPACE 0.0 21 SPACE 0.0 23 SPACE 0.0 TOTALS: B NOTES: 2.0 1.8 1.8 1.0 0.0 0.0 0.0 0.0 0.0 0.0 0.6 0.7 1.2 1.2 7.8 7.8 7.8 0.6 0.6 0.6 0.7 0.7 0.7 2.1 2.1 2.1 CKT AMP POLE NO 3.9 SKID C COOLER 3.9 20 3 2 3.9 - 3.9 - - - 3.9 - 3.9 - - - 0.3 SKID C PRELUBE 0.3 15 3 4 0.3 - 0.3 - - - 0.3 - 0.3 - - - 0.3 SKID C HEATER 0.3 15 3 6 0.9 - 0.9 - - - 0.9 - 0.9 - - - 3.9 (F) SKID D COOLER 3.9 20 - 8 3.9 - 3.9 - - - 3.9 - 3.9 - - - 0.3 (F) SKID D PRELUBE 0.3 15 - 10 0.3 - 0.3 - - - 0.3 - 0.3 - - - 0.3 (F) SKID D HEATER 0.3 15 - 12 0.3 - 0.3 - - - 0.3 - 0.3 - - 0.0 SPACE 14 0.0 - - 0.0 - - - 20.7 CONNECTED TOTAL kVA 61.7 CONNECTED AMPS PER PHASE 73.0 74.9 74.9 CONNECTED AVERAGE AMPS PER PHASE 74.3 0 kVA ALL OTHER LOADS @100% = 61.7 kVA DIVERSIFIED TOTAL kVA = 64.6 RECEPTACLES 0kVA @100% = 0 kVA 25% OF LARGEST MOTOR = 2.9 kVA AVERAGE AMPS PER PHASE = 77.7 REMAINDER 0kVA @ 50% = 0 kVA VOLTS/PHASE/WIRE: LTG CO MASTER CONTROL (MCP) OCP CKT CKT LOAD (kVA) OCP AMP POLE NO NO AMP POLE 1.2 20 1 2 1 15 1 PANEL SIZE & TYPE: MAIN SIZE & TYPE: LOCATION: CABINET: NOTES: 100 AMP DIST BLOCK 60 AMP BREAKER MCC NEMA 3R ON SHUNT TRIP 1.8 20 1 4 3 15 1 20 1 6 5 15 1 20 2 8 7 15 1 - 10 9 15 1 12 11 15 1 LTG CO DESCRIPTION LCL PWR A 1.6 1.2 MCC PLC 1.2 0.4 SKID A CONTROL 0.4 SKID A LIGHTING 0.6 0.4 SKID B CONTROL 0.4 SKID B LIGHTING 0.6 0.4 SKID C CONTROL 0.4 SKID C LIGHTING 0.6 0.4 FUTURE SKID D CONTROL 0.4 FUTURE SKID D LIGHTING 0.6 AIR DRYER 1.0 UTILITY ROOM OUTLETS 1.3 208V OULET FOR HVAC 1.3 1.3 - 1.3 - 0.5 SPARE 0.5 20 0.0 SPACE 14 13 15 1 0.0 SPACE 16 15 15 1 0.0 SPACE 18 17 15 1 0.0 SPACE 20 19 SPACE 0.0 0.0 SPACE 22 21 SPACE 0.0 0.0 SPACE 24 23 SPACE 0.0 CONNECTED kVA PER PHASE 4.2 5.1 3.0 CONNECTED TOTAL kVA 12 35.0 42.1 25.0 CONNECTED AVERAGE AMPS PER PHASE 34 0.5 0.5 0.5 0.5 TOTALS: (S) = SHUNT TRIP WITH SWITCHED NEUTRAL PHASE LOAD kVA 1.8 1.0 REVISIONS: REV NO. B LCL C 0.8 1.0 1.4 1.0 0.9 1.0 0.9 1.0 0.5 0.0 0.0 LOAD (kVA) DESCRIPTION kVA LTG CO OCP AMP POLE NO 2 0.4 VALVE PANEL PLC 0.4 15 1 0.5 DISPENSER 1 (S) 0.5 15 1 4 0.5 DISPENSER 2 (S) 0.5 15 1 6 1.0 QUAD OUTLETS 15 1 8 0.5 SPARE 0.5 15 1 10 0.5 SPARE 0.5 15 1 12 0.5 SPARE 0.5 14 0.5 SPARE 0.5 16 0.5 SPARE 0.5 18 0.5 SPARE 0.5 20 0.0 SPACE 22 0.0 SPACE 24 1.0 CONNECTED kVA PER PHASE 4.5 2.7 2.8 CONNECTED TOTAL kVA 10 CONNECTED AMPS PER PHASE 37.2 22.5 23.7 CONNECTED AVERAGE AMPS PER PHASE 28 ADDRESS: (S) = SWITCHED NEUTRAL C/B NEC DIVERSIFIED LOAD CALCULATIONS LIGHTING 3kVA @125% = 3.1 kVA ALL OTHER LOADS @100% = 8.8 kVA DIVERSIFIED TOTAL kVA = 12.9 LIGHTING 2kVA @125% = 2.5 kVA ALL OTHER LOADS @100% = 5.4 kVA DIVERSIFIED TOTAL kVA = 8.9 1.0 kVA 25% OF LARGEST MOTOR = 0.0 kVA AVERAGE AMPS PER PHASE = 35.7 RECEPTACLES 1kVA @100% = 1.0 kVA 25% OF LARGEST MOTOR = 0.0 kVA AVERAGE AMPS PER PHASE = 24.7 REMAINDER 0kVA @ 50% = 0.0 kVA REMAINDER 0kVA @ 50% = 0.0 kVA DAT FAULT CURRENT MCC 65,000 SCA L1 10,000 SCA LS2 10,000 SCA HS1 65,000 SCA SKID MOUNTED MCC 65,000 SCA L3 10,000 SCA REV DATE CKT PWR RECEPTACLES 1kVA @100% = FAULT CURRENT TABLE DESCRIPTION PANEL DIRECTORY, IDENTIFICATION, GROUNDING BAR, INSULATED GROUND BAR, SUBFEED LUGS PWR CONNECTED AMPS PER PHASE NEC DIVERSIFIED LOAD CALCULATIONS 0.6 OCP PWR (F) = FUTURE 120/208 V, 3 PH, 4 WIRE LOAD (kVA) DESCRIPTION kVA 1.2 3.3 0.6 CO LIGHTING 0kVA @125% = ACCESSORIES: LCL C 7.8 LTG PANEL "LS2" PANEL DIRECTORY, IDENTIFICATION, GROUNDING BAR, INSULATED GROUND BAR, SUBFEED LUGS ACCESSORIES: 7.8 LOAD (kVA) DESCRIPTION kVA 20.7 PANEL "L1" 120/208 V, 3 PH, 4 WIRE LCL C 20.2 NEC DIVERSIFIED LOAD CALCULATIONS VOLTS/PHASE/WIRE: B CONNECTED kVA PER PHASE TOTALS: CKT A - GAS DRYER PHASE LOAD kVA 120/208 TRANSFORMER 0.0 66.5 OCP 8.3 0.0 66.5 CKT CO 11.1 66.5 OCP LOAD (kVA) CKT LTG 8.8 11.1 66.5 LOAD (kVA) PANEL / EQUIPMENT LCL C NOTES: PANEL DIRECTORY, IDENTIFICATION, GROUNDING BAR, INSULATED GROUND BAR, SUBFEED LUGS ACCESSORIES: NO 7 VOLTS/PHASE/WIRE: 480 V, 3 PH, 3 WIRE 14207 DEL MONTE BLVD MONTEREY, CA 93933 CHECKS: C COGGINS 2015-01-21 J BARBER PROJECT NAME: PROVIDE FULLY RATED CIRCUIT BREAKERS IN PANELBOARDS FOR THE FAULT CURRENT SHOWN. SERIES RATINGS WITH NEXT LEVEL UPSTREAM OVERCURRENT PROTECTIVE DEVICES ARE PERMITTED SUBJECT TO FACTORY UL DOCUMENTATION OF SERIES RATING SUBMITTED TO ENGINEER. IF DEVICE OR EQUIPMENT FAULT CURRENT RATING IS NOT SHOWN, ASSUME 100,000 AIC. LS2 IS SERIES RATED WITH L1. CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: PANEL SCHEDULE SHEET: E-15 ENGINEER STAMP: (2'-0") 6" 6'-0" 5" 5" 2'-1 " 1 2 3'-0" 1 2 1 4 PROVIDED BY TRILLIUM CONTRACTOR TO INSTALL PROVIDED BY TRILLIUM CONTRACTOR TO INSTALL 1'-0" PROVIDED BY TRILLIUM CONTRACTOR TO INSTALL C20 PROVIDED BY TRILLIUM CONTRACTOR TO INSTALL MASTER CONTROL PANEL (MCP) C24 30 KVA TRANSFORMER MAIN BREAKER C25 MOTOR CONTROL CENTER AND DISTRIBUTION (MCC) 3 4 4'-3 " 72" X 72" X 24" REVISIONS: REV NO. 2 REV DATE 2 7'-0" X 12" X 12" GUTTER 1'-0" C21 C22 1'-0" 1 DESCRIPTION ADDRESS: C46 C39 C35 C31 C27 C42 C38 C34 C30 C26 C19 C19 C19 C19 14207 DEL MONTE BLVD MONTEREY, CA 93933 SEAL OFF'S ON ALL CONDUITS BOTTOM VIEW SEAL OFF'S ON ALL CONDUITS C COGGINS C59 C57 C55 C45 C43 C37 C29 C11 C09 C07 C05 C02 C52 C51 C49 C47 C36 C28 C01 CHECKS: 2015-01-21 J BARBER GENERAL SHEET NOTES 1. TRILLIUM WILL SUPPLY THE FOLLOWING EQUIPMENT, CONTRACTOR TO INSTALL: REMOTE MAIN BREAKER, MOTOR CONTROL CENTER, 30 kVA TRANSFORMER, MASTER CONTROL PANEL, NETWORK COMMUNICATION BOX. ALL UNDERGROUND CONDUITS SHALL HAVE SEAL OFFS AS THE FIRST JOINT ABOVE GROUND IN HAZERDOUS AREAS. ALL CONDUITS ON EXPLOSION PROOF FIXTURES AND ENCLOSURES SHALL HAVE SEAL OFFS ON FIRST CONDUIT INTO OR OUT OF THE FIXTURE OF ENCLOSURE. 1. CONTRACTOR TO INSTALL GUTTER FOR MCP & MCC CONDUIT WIRE ROUTING. SEE SHEET E-7 FOR CONDUIT AND CONDUCTOR SCHEDULE. 2. CONTRACTOR TO INSTALL TWO (2) 2" CONDUITS BETWEEN ELECTRICAL GUTTER AND MASTER CONTROL PANEL. INSTALL CONDUITS SUCH THAT KEYBOARD CAN FULLY RETRACT. ALL WIRE PULLED INTO MASTER PANEL PULL BOX WILL BE LABELED ON BOTH ENDS WITH CLEAR TO READ NUMBERS. CONTRACTOR TO SUPPLY REVISED CONDUIT SCHEDULE LISTING WIRE NUMBERS LOCATED IN WHICH CONDUITS. 7. CONTRACTOR TO SUPPLY TEN FOOT MINIMUM EXTRA WIRE IN MASTER PANEL PULL BOX TO ALLOW FOR WIRE TO BE PULLED INTO RESPECTIVE PANELS. WIRE TO BE COILED NEATLY AND TIED PER CONDUIT. 8. C58 C56 C54 C44 C41 CONTROL CONTROL & COMM ELEVATION 6. 3. CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: ALL CONDUITS SHALL HAVE SEAL OFFS WHERE ENTERING OR LEAVING CLASSIFIED LOCATIONS PER NEC. 501. CONTRACTOR TO PROVIDE AND INSTALL GUTTER BOX (7'-0" X 1'-0" X 1'-0"). C33 C16 C10 C08 C06 C03 C53 C52 C50 C48 C40 120V POWER 5. 2. 4. C32 C04 PROJECT NAME: SHEET KEY-NOTES SHEET: E-16 ENGINEER STAMP: CA Marina MCC - BILL OF MATERIALS 28 24 24 1 27 17 18 16 11 24V 24 # QUANTITY MANUFACTURER 1 3 ILSCO 1600A DISTRIBUTION BLOCK 2 4 EATON 400A MOTOR BREAKER 3 4 EATON COMPRESSOR MOTOR SOFT START - 200 hp 4 1 EATON 60A DRYER CONTACTOR 5 1 EATON 60A "LS2" CONTACTOR 6 8 EATON COMBINATION STARTERS 1 - 1.6 FLA W\ SIDE MOUNT TRIP INDICATOR 7 1 EATON COMBINATION STARTERS 10 - 16 FLA W\ SIDE MOUNT TRIP INDICATOR 8 4 EATON COMBINATION STARTERS 6.3 - 10 FLA W\ SIDE MOUNT TRIP INDICATOR 9 1 EATON 30 kVA XFMR 10 3 ILSCO POWER DIST. BLOCK 11 1 EATON 24Vdc, 10A POWER SUPPLY 12 24 EATON L1 120V 20A BREAKERS 13 24 EATON LS2 120V 15A BREAKERS 14 1 EATON 100A "HS1" BREAKER 15 1 EATON 60A DRYER BREAKER 16 1 EATON 50A XFMR BREAKER 17 1 EATON 60A "LS2" MAIN BREAKER 18 1 EATON 50A "L1" MAIN BREAKER DESCRIPTION 9 10A 10 Adjust DC OK L1 L2 L3 3 Phase 400-500V~ 0.8A 50-60Hz 1 21 22 24 4 19 5 20 25 1 23 MAIN BREAKER GROUND 24 12 2 2 2 13 2 24 15 23 NEUTRAL 26 23 GROUND 14 3 3 3 3 24 6 6 7 6 6 7 6 7 6 6 6 7 8 REVISIONS: REV NO. 19 3 DAYTON RELAY BASE 20 3 DAYTON RELAY 21 2 N/A 22 12 PHOENIX CONTACT 23 3 N/A TERMINAL BAR 24 1 N/A 2.25" PANDUIT 25 30 C3 CONTROLS 26 1 EATON 20A LIGHTING CONTACTOR 27 1 EATON 1600A SERVICE ENTRANCE BREAKER W/ CABINET 28 1 HOFFMAN DESCRIPTION REV DATE DIN RAIL DIN RAIL WIRE CLAMP TERMINAL BLOCK 72" X 72" X 24" ENCLOSURE W/LEGS ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 HOLES FOR CONDUIT SEE E-7 FOR SIZE OF RIGID CONDUIT COMPRESSION FITTING (TYP) CAP ANY UNUSED HOLES BOTTOM VIEW CHECKS: C COGGINS 2015-01-21 (6'-8 1/2") J BARBER 3 1/2" PROJECT NAME: 10" 3 1/2" TYP (6'-6 3/4") 8" 8" 8" 8" 8" 4" 4" 4" 4" 4" 1'-0" 1'-0" 8" 4" C46 C39 C35 C31 C27 C42 C38 C34 C30 C26 1'-2" 3 1/2" TYP CA MARINA MRWMD CNG FUELING STATION 5 1/4" DRAWING NAME: 7'-0" MCC PANEL HOLES FOR CONDUIT SEE E-7 FOR SIZE SHEET: E-17 ENGINEER STAMP: MAIN MOTOR PRE-LUBE / HEATER COOLER MOTOR PANEL COMMUNICATION 1'-4" 6'-10 1/2" 1'-10" 1'-11 3/4" 3" PANEL POWER PRE-LUBE / HEATER COOLER MOTOR PANEL COMMUNICATION MAIN MOTOR REVISIONS: REV NO. B E-18 1'-10" 1'-4" 3" DESCRIPTION REV DATE B GAS COMPRESSOR PIPE DETAIL E-18 9" 1'-7" 6'-10 1/2" 1'-7" PANEL POWER PANEL COMMUNICATION ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 PRE-LUBE / HEATER COOLER MOTOR MAIN MOTOR (3) THREE CONDUITS ARE INLINE. ONLY ONE SHOWN CONTROL (C1) POWER (C2) PRELUB COOLER& HEATER (C7) MAIN MOTOR (C9) CHECKS: C COGGINS 2015-01-21 1'-7" A GAS COMPRESSOR PIPE DETAIL E-18 C COMPRESSOR PIPE DETAIL E-18 1'-7" 1'-11 3/4" 10 1/2" 10 1/2" J BARBER 1'-11 3/4" C E-18 9" 10 1/2" 1'-7" 1'-7" 8" PANEL POWER PROJECT NAME: CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: COMPRESSOR CONDUIT PLAN AND ELEVATION SHEET: E-18 ENGINEER STAMP: SEAL OFF REVISIONS: REV NO. DESCRIPTION REV DATE ADDRESS: 14207 DEL MONTE BLVD MONTEREY, CA 93933 6" CHECKS: SEAL OFF C COGGINS 2'-5" 2'-5" 2015-01-21 2'-8" J BARBER 2'-8" PROJECT NAME: DRYER POWER SEAL OFF DRYER POWER DRYER COMMUNICATION DRYER COMMUNICATION A GAS DRYER CONDUIT DETAIL E-19 PLAN VIEW CA MARINA MRWMD CNG FUELING STATION DRAWING NAME: B GAS DRYER CONDUIT DETAIL E-19 ELEVATION VIEW DRYER CONDUIT PLAN AND ELEVATION SHEET: E-19