D1.0
DEMOLITION PLAN
A1.0
FLOOR AND CLG. PLAN & NOTES
A1.1
FINISH SCHEDULE AND DETAILS
A2.0
EQUIPMENT PLAN & SCHEDULE
A3.0
STOREFRONT ELEVATIONS
A3.1
KITCHEN ELEVATIONS
A4.0
DETAILS
AS1.0
ARCHITECTURAL SPECIFICATIONS
E1.0
ELECTRICAL POWER AND LIGHTING PLANS
E2.0
DETAILS, PANEL SCHEDULES AND RISER DIAG.
E3.0
ELECTRICAL SPECIFICATIONS
PHILADELPHIA MILLS
H1.0
HOOD DRAWING
H2.0
HOOD DRAWING
SPACE 852A ~ 818 SQ. FT.
H3.0
HOOD DRAWING
1455 FRANKLIN MILLS CIR, PHILADELPHIA, PA, 19154
M1.0
MECHANICAL PLAN, DETAILS, & NOTES
P1.0
PLUMBING WATER & WASTE PLANS
P2.0
GAS PLANS, WATER AND WASTE ISOMETRICS
GENERAL REQUIREMENTS
1. PERMITS AND FEES
2. TEMPORARY UTILITIES
4. TEMPORARY ENCLOSURE
SPACE WORK
1.
2.
DEMOLITION
SAW CUT SLAB/CORE DRILL
AS REQUIRED TO INSTALL UTILITIES, CORE DRILL ONLY
CONCRETE SLAB CORE DRILLING
1.
2.
3.
4.
5.
SAND PAD
VAPOR BARRIER
REINFORCING FABRIC
CONCRETE SLAB
POURED CONCRETE
AS REQUIRED TO INSTALL UTILITIES
CARPENTRY
1.
2.
METAL STUDS
A. DEMISING WALLS
B. INTERIOR PARTITIONS
C. FURRING
D. SALES COUNTER
E. SALES LOW WALL
ROOF FRAMING FOR MECH. UNITS
SEE PLANS
KEY PLAN
DOORS
1.
2.
3.
SEE SCHEDULE
SEE SCHEDULE
SALES/KITCHEN DOOR(S) & FRAME
SERVICE DOOR
TOILET ROOM DOOR
SYMBOLS LEGEND:
FINISHES
1.
2.
3.
4.
5.
6.
WALLS
A. 5/8" TYPE "X" GYP. BD.
B. 5/8" MOISTURE RESISTANT GYP. BD.
C. FINISHES
D. COUNTER TOP MATERIAL
SEE PLAN AND STANDARD MATERIAL SCHEDULE
G.C. TO SUPPLY SAMPLES TO OWNER FOR APPROVAL
TAPING AND SPACKLING
FLOORS
A. WATER PROOF MEMBRANE
B. QUARRY TILE
C. DINING FLOORING
FINISHES
A. PAINT
FOR ALL WET AREAS OF SLAB + FLOOD TEST TO BE
WITNESSED BY LL. T.C.
PLAN DETAIL
INDICATION
ELEVATION
INDICATION
DOOR
IDENTIFICATION
B. TILE
C. TRIM
BASE
A. COVED QUARRY TILE
B. COVED VINYL
CEILING
A. GYP. BD.
B. 2'X4' LAY-IN TILE
SEE REFLECTED CEILING
SEE REFLECTED CEILING
MALL PROVIDED
PUBLIC RESTROOMS
WITH-IN 300' FROM
TENANT SPACE
PLUMBING
1.
2.
3.
4.
5.
6.
SECTION CUT
INDICATION
CHARLEY'S
PHILLY STEAKS
SPC# 852A
818 SQ. FT.
WATER PIPING
UNDERSLAB ROUGH-IN FOR WASTE
FINAL CONNECTIONS & VENTS
GAS PIPING AND ACCESSORIES
FINAL GAS CONNECTIONS TO EQUIP.
TOILET RM. FIXTURES/ACCESSORIES
SEE
SEE
SEE
SEE
SEE
PLUMBING
PLUMBING
PLUMBING
PLUMBING
PLUMBING
DWG.
DWG.
DWG.
DWG.
DWG.
1.
2.
3.
4.
5.
KITCHEN/SALES
STOREFRONT SIGNS
FIRE EXTINGUISHER
INTERCOM SYSTEM
SEATING
SEE EQUIPMENT SCHEDULE FOR MORE INFO.
COORD. PERMITS & INSTALLATION W/ SIGN VENDOR
LOCATE PER FIRE MARSHALL
6.
7.
MENU BOARD
SALES AREA S/S COUNTERS
COORDINATE WITH VENDOR (VERIFY W/ TENANT)
COORDINATE WITH TENANT.
SEE ELECTRICAL DRAWINGS
SEE ELECTRICAL DRAWINGS
SEE ELECTRICAL DRAWINGS
SEE ELECTRICAL DRAWINGS
HVAC SYSTEM
A. HVAC UNIT
B. DUCTWORK
2.
3.
4.
5.
6.
7.
8.
9.
C. DIFFUSERS
ROOF PENETRATIONS
SPRINKLER SYSTEM
EXHAUST HOODS & FANS
EXHAUST HOOD DUCT WORK
EXHAUST HOOD ANSUL SYSTEM
ROOF PROTECTION ACCESSORIES
EXH. HOOD MUA SUPPLY SYSTEM
FIRE ALARM AND SMOKE CONTROL SYS.
INSTALL/ MODIFY EXISTING SYSTEM PER L.L. REQUIREMENTS
SEE HOOD DWG.
COORD. W/ LL'S ROOFER FOR ROOFING WORK @ TEN.'S EXPENSE.
SEE HOOD DWG.
INSTALL SPEAKER/STROBE SYSTEM PER L.L. REQUIREMENTS
PROJECT INFORMATION:
LANDLORD:
SIMON PROPERTY GROUP, INC.
225 WEST WASHINGTON STREET
INDIANAPOLIS, IN 46204
TEL. 317-636-1600
PROJECT
COORDINATOR
MOSAD ELEWA
3386 CLARINE WAY WEST
DUNEDIN, FL 34698
TEL: 813-245-6554
FAX: 801-218-6554
ARCHITECT
DAVID HIATT, ARCHITECT
4410 W MELROSE AVE.
TAMPA, FL 33629
TEL: (813) 333-2717
FAX: (813) 289-3332
OWNER / TENANT
BUILDING DEPT.
HEALTH DEPT.
CPS OF PHILLY, LLC
10305 NW 41ST ST SUITE 201
DORAL, FL 33178
CITY OF PHILADELPHIA
DEPARTMENT OF LICENSES &
INSPECTIONS
1401 JOHN F. KENNEDY BLVD
PUBLIC SERVICES CONCOURSE
PHILADELPHIA, PA 19102-1687
TEL.: (215) 686-1776
PHILADELPHIA DEPARTMENT OF
PUBLIC HEALTH OFFICE OF FOOD PROTECTION
321 UNIVERSITY AVE.,
2ND FLOOR
PHILADELPHIA, PA 19104
TEL.: (215) 685-7495
TEL: (305) 406-1583
ABOVE FINISH FLOOR
ACT.
ADJ.
A.C.
ACOUSTICAL
ADJUSTABLE
AIR CONDITION/CONDITIONED/
ALT.
ALUM.
A.B.
&
APPROX.
@
AWN.
MECHANICAL
1.
A.F.F.
B.C.
B.P.
BM.
BLK.
B.S.
B.W.
BTM.
BRK.
BLDG.
CAB.
CPT.
C.I.
C.B.
CLG.
CEM.
CTR.
C.T.
CHBD.
C.O.
CLO.
COL.
COM.
CONC.
CONST.
C.M.U.
CONT.
CONTR.
C.J.
C.TOP
DEMO.
DEPART.
DTL.
DIA.
DIM.
DR.
DN.
DWG.
EA.
E.
ELEC.
E.C.
E.W.C.
ELEV.
ENCL.
EQ.
EQUIP.
EXIST.
E.J.
EXP.
EXT.
CONDITIONER/CONDITIONING
ALTERNATE
ALUMINUM
ANCHOR BOLT
AND
APPROXIMATELY
AT
AWNING
BASE CABINET
BASE PLATE
BEAM
BLOCK
BOTH SIDES
BOTH WAYS
BOTTOM
BRICK
BUILDING
CABINET
CARPET
CAST IRON
CATCH BASIN
CEILING
CEMENT
CENTER
CERAMIC TILE
CHALKBOARD
CLEAN OUT
CLOSET
COLUMN
COMBINATION
CONCRETE
CONSTRUCTION
CONCRETE MASONRY UNIT
CONTINUOUS
CONTRACTOR
CONTROL JOINT
COUNTER TOP
DEMOLITION
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DOOR
DOWN
DRAWING
EACH
EAST
ELECTRICAL
ELECTRICAL CONTRACTOR
ELECTRIC WATER COOLER
ELEVATION
ENCLOSURE
EQUAL
EQUIPMENT
EXISTING
EXPANSION JOINT
EXPOSED
EXTERIOR
F.O.S.
FT.
F.N.D.
F.N.V.
FIN.
FIN. OPNG.
F.E.
F.E.C.R.
F.H.
F.R.P.
F.R.T.
FL.
F.D.
F.P.
FTG.
F.M.
GALV.
GA.
G.C.
GL.
G.B.
G.W.B.
GYP.
HC.
HDW.
HT.
H.
H.C.
H.M.
HORIZ.
IN.
INCL.
I.D.
INSUL.
JT.
JST.
LAM.
L.L.
LAV.
L.
MGR.
M.H.
MFR.
MAS.
M.O.
MAT'L.
MAX.
MECH.
MT.
M.F.
M.S.
MIN.
M.
MISC.
M.R.
M.B.H.
1
CONSTRUCTION
NOTES
1.
TOILET
ACCESSORIES
A
GENERAL
NOTES
3).
PLATE
MTD.
N.
N.I.C.
N.T.S.
NO.
NOTES WHICH APPLY
TO SPECIFIC ITEMS
ON DRAWINGS WHERE
INDICATED.
NOTES WHICH APPLY
TO ALL DRAWINGS.
00'-0"
ABOVE
FIN. FLR.
C
C
LEASE LINE
ELEVATION
SURFACE
DESCRIPTION
CENTERLINE
DIAMETER
CODE INDEX
FACE OF STUD
O.C.
OPNG.
FEET
O.D.
FEMININE NAPKIN DISPOSAL
PR.
FEMININE NAPKIN VENDOR
P.T.D.
FINISH
FINISH OPENING
P.T.H.
FIRE EXTINGUISHER
P.COL.
FIRE EXTINGUISHER CABINET
PLAS.
RECESSED
P.LAM.
FIRE HYDRANT
PLUMB.
FIRE RETARDANT PANEL
P.C.
FIRE RETARDANT TREATED
PLYWD.
FLOOR
P.T.
FLOOR DRAIN
Q.T.
FLUSH PANEL
R.
FOOTING
RECT.
FRAMED MIRROR
REINF.
GALVANIZED
REQ'D.
GAUGE
REV.
GENERAL CONTRACTOR
R.D.
GLASS
RM.
GRAB BAR
R.O.
GYPSUM WALLBOARD
S.C.O.F.
GYPSUM
SCH.
HANDICAPPED
SNT.
HARDWARE
SECT.
HEIGHT
SHT.
HIGH
SIM.
HOLLOW CORE
S.D.
HOLLOW METAL
S.H.
HORIZONTAL
S.C.
INCH
S.
INCLUDE
SPECS.
INSIDE DIAMETER
SQ.
INSULATION
JOINT
SQ.FT.
JOIST
S.S.
STD.
LAMINATED
STL.
LANDLORD
STR.
LAVATORY
S.M.S.
LONG
MANAGER
SUSP.
MANHOLE
SYS.
MANUFACTURER
TKBD.
MASONRY
T.C.
MASONRY OPENING
T.P.H.
MATERIAL
T.& G.
MAXIMUM
T.B.
MECHANICAL
TYP.
METAL
METAL FRAME
U.N.O.
METAL STUD
V.T.R.
MINIMUM
VERT.
MIRROR
V.T.
MISCELLANEOUS
MOISTURE RESISTANT
MOP AND BROOM
HOLDER
MOUNTED
NORTH
NOT IN CONTRACT
NOT TO SCALE
NUMBER
SHEET NUMBER
A
L.L.
1. CONDUIT INTO SPACE
2. METER
3. PANELS
4. TRANSFORMER AND GEAR
5. LIGHT FIXTURES AND LAMPS
6. TELEPHONE WIRING
ELEVATION NUMBER
MILWORK
MOULDINGS
PHILADELPHIA MILLS
ABBREVIATIONS:
DETAIL AREA
DETAIL NUMBER
SHEET NUMBER
0
A-0
P
ELECTRICAL
SHEET NUMBER
0
A-0
ELEVATION TARGET
EQUIPMENT
SECTION NUMBER
0
A-0
PHILADELPHIA, PA 19154
COVER SHEET
1455 FRANKLIN MILLS CIR,
C1.0
SPACE 852A ~ 818 SQ. FT.
REMARKS
PHILADELPHIA MILLS
DRAWING INDEX
N/A
TENANTS
CONT
TENANT
LANDLORD
TENANTS
CONT
INSTALLED
TENANT
ITEM:
FURNISHED
LANDLORD
EXISTING
RESPONSIBILITY SCHEDULE
W.R.
W.C.
W.H.
W.P.
W.
W/.
W/O.
WD.
ON CENTER
OPENING
OUTSIDE DIAMETER
PAIR
PAPER TOWEL
DISPENSER
PAPER TOWEL HOLDER
PIPE COLUMN
PLASTER
PLASTIC LAMINATE
PLUMBING
PLUMBING CONTRACTOR
PLYWOOD
PRESSURE TREATED
QUARRY TILE
RADIUS
RECTANGULAR
REINFORCEMENT
REQUIRED
REVISION
ROOF DRAIN
ROOM
ROUGH OPENING
SLIP COEFFICIENT
SCHEDULE
SEALANT
SECTION
SHEET
SIMILAR
SOAP DISPENSER
SOAP HOLDER
SOLID CORE
SOUTH
SPECIFICATIONS
SQUARE
SQUARE FEET
STAINLESS STEEL
STANDARD
STEEL
STRUCTURAL
STRUCTURAL METAL
STUD
SUSPEND
SYSTEM
TACKBOARD
TENANT CO-ORDINATOR
TOILET PAPER HOLDER
TONGUE AND GROOVE
TOWEL BAR
TYPICAL, UNLESS
OTHERWISE NOTED
UNLESS NOTED OTHERWISE
VENT THROUGH ROOF
VERTICAL
VINYL TILE
WASTE RECEPTACLE
WATER CLOSET
WATER HEATER
WATER PROOF
WEST / WIDE
WITH
WITHOUT
WOOD
BUILDING CODES:
PHILADELPHIA CODE
·
THE PHILADELPHIA ADMINISTRATIVE CODE
·
PHILADELPHIA BUILDING CODE
·
PHILADELPHIA MECHANICAL CODE 2009
·
PHILADELPHIA EXISTING BUILDING CODE
·
PHILADELPHIA ELECTRICAL CODE
·
PHILADELPHIA PERFORMANCE CODE
·
PHILADELPHIA ENERGY CONSERVATION CODE
·
PHILADELPHIA FIRE CODE
·
PHILADELPHIA FUEL GAS CODE
·
PHILADELPHIA ZONING CODE
·
PHILADELPHIA PLUMBING CODE
INTERNATIONAL CODE COUNCIL
·
2009 INTERNATIONAL BUILDING CODE
·
2012 INTERNATIONAL BUILDING CODE (CHAPTER 11)
·
2012 INTERNATIONAL BUILDING CODE (APPENDIX E)
·
2009 ICC A117.1
·
2009 INTERNATIONAL MECHANICAL CODE
·
2009 INTERNATIONAL EXISTING BUILDING CODE
·
2009 INTERNATIONAL ENERGY CONSERVATION CODE
·
2009 INTERNATIONAL FUEL GAS CODE
·
2009 ICC PERFORMANCE CODE
GENERAL NOTES
TYPE OF CONSTRUCTION
OCCUPANCY CLASS:
TOTAL LEASED AREA:
MAXIMUM ALLOWABLE AREA:
OCCUPANT LOAD:
IIB, FULLY SPRINKLED
GROUP ' B '
818 S.F.
818 S.F.
4 WORKERS AT ALL TIME
REQUIRED EXIT WIDTH:
PROVIDED EXIT WIDTH:
36" INCHES
36" INCHES
U 465 UL DESIGN NUMBER FOR TENANT
SEPARATION.
LANDLORD NOTES
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
1. THESE DOCUMENTS REPRESENT THE SCOPE OF WORK TO BE TO PERFORMED BY THE GENERAL CONTRACTOR (U.N.O.)
2. CHECK DIMENSIONS AND CONDITIONS IN THE FIELD ALL DIMENSIONS AND CONDITIONS OF THIS JOB SHALL BE FIELD
CHECKED BY GENERAL CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME. ANY DISCREPANCIES SHALL BE REPORTED TO THE
ARCHITECT PRIOR TO THE START OF CONSTRUCTION. COSTS DUE TO A FAILURE OF REPORTING THESE DISCREPANCIES WILL BE
THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
3. ERRORS AND OMISSIONS ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION
OF THE ARCHITECT PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY THE CONTRACTOR TO
IDENTIFY DISCREPANCIES OR OMISSIONS WILL THEN BECOME THE RESPONSIBILITY OF THE CONTRACTOR.
4. COMPLY WITH DESIGN CRITERIA
GENERAL CONTRACTOR TO FOLLOW AND COMPLY WITH LANDLORD'S TENANT DESIGN CRITERIA AND REQUIREMENTS FOR ALL
EXHIBITS. ( IF APPLICABLE. )
5. NOTES
ALL NOTES ON ANY PORTION OF THESE DOCUMENTS APPLY TO ENTIRE DOCUMENT WHETHER OR NOT THEY ARE REPEATED IN
OTHER AREAS.
6. WORK, MATERIALS AND CONSTRUCTION METHODS
ALL WORK, MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM WITH ALL GOVERNING AUTHORITIES HAVING
JURISDICTION.
7. APPROVAL BY GOVERNING AUTHORITIES
APPROVAL OF THESE DRAWINGS BY GOVERNING AUTHORITIES DOES NOT RELEASE THE CONTRACTOR FROM COMPLYING WITH
ALL APPLICABLE CODES AND STANDARDS.
8. INSTALLATION BY GENERAL CONTRACTOR
ALL MATERIALS AND EQUIPMENT ITEMS SUPPLIED BY THE OWNER/TENANT ARE TO BE INSTALLED BY GENERAL CONTRACTOR
UNLESS INDICATED OTHERWISE.
SPECIAL NOTES:
9. MATERIALS
ALL MATERIALS SHALL BE NEW AND FIRST CLASS. ALL WORK AND EQUIPMENT ITEMS SHALL BE WARRANTIED BY THE
CONTRACTOR FOR A MINIMUM OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE. EXCEPT FOR MANUFACTURE'S WARRANTY
WHICH MAY BE LONGER.
10. COMBUSTIBLE MATERIALS
NO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING.
COVER SHEET
11. FIRE EXTINGUISHERS
CAPACITY AND RATING AS REQUIRED BY N.F.P.A. PAMPHLET #10 AND LOCAL AUTHORITIES. LOCATE PER LOCAL AUTHORITIES
AND N.F.P.A. 10. VERIFY LOCATION WITH FIRE DEPARTMENT
12. MISC.
PRIOR TO INSTALLING SHELVING IN REFRIGERATOR, T.G.C. TO WASH DOWN (SPONGE) INTERIOR THREE (3) TIMES WITH A
SOLUTION OF 50% VINEGAR AND 50%WATER. SET REFRIGERATOR TO OPERATE AT 34 - 38 F RANGE.
13.
PERFORMANCE BOND AND PAYMENT BONDS ARE REQUIRED FOR THIS PROJECT. REFER TO SHEET AS-1.
14. SOME SPECIFIED ITEMS (SUCH AS FLUORESCENT FIXTURES IN SALES COUNTER, WALL STANDARDS, SHELVING BRACKETS,
CERAMIC TILE, ETC.) MAY REQUIRE LONG DELIVERY
15. CONTRACTOR AND ALL SUB-CONTRACTORS SHALL VISIT JOB SITE PRIOR TO THE BID. TO REVIEW ACTUAL FIELD CONDITIONS
THAT MAY AFFECT THE BID. CONTACT ARCHITECT WITH ANY FIELD CONDITION AFFECTING DRAWINGS BEFORE BID TO OWNER. IF
NOT COMMUNICATED WITH THE ARCHITECT, THEN CONTRACTOR & SUB-CONTRACTOR WILL BECOME RESPONSIBLE FOR ALL COSTS
INVOLVED.
16. COMPLY WITH ALL LANDLORD'S TENANT WORK RULES & INSURANCE REQUIREMENTS.
C1.0
DEMOLITION NOTES
3
GENERAL CONTRACTOR SHALL COORDINATE WITH LANDLORD REP. AND REMOVE EXISTING DEMISING WALL AND INSTALL NEW DEMISING WALLS PER PLANS
4
GENERAL CONTRACTOR SHALL COORDINATE WITH LANDLORD REP. AND REMOVE EXISTING STOREFRONT SYSTEMS. TO NEW LEASE LINES
5
GENERAL CONTRACTOR SHALL REMOVE EXISTING CEILING THROUGH OUT THE LEASED AREA.
6
GENERAL CONTRACTOR SHALL REMOVE EXISTING HVAC UNITS AND DUCTWORK. INSTALL NEW PER MECHANICAL DRAWING.
7
GENERAL CONTRACTOR SHALL REMOVE EXISTING LIGHT THROUGH OUT LEASE AREA, INSTALL NEW FIXTURES PER REFLECTED CEILING PLAN.
8
EXISTING LANDLORD NEUTRAL PIERS TO REMAIN. PATCH AND REPAIR TO A "LIKE NEW" APPRARANCE
9
GENERAL CONTRACTOR SHALL REMOVE EXISTING FLOORING AND BASE & PREPARE FLOOR SLAB TO RECEIVE NEW FLOOR FINISH. SEE ROOM FINISH SCHEDULE ON SHEET A-1.
10
REMOVE PORTION O EXISTING STOREFRONT BULKHEAD
11
GENERAL CONTRACTOR SHALL COORDINATE WITH LANDLORD REPRESENTATIVE FOR THE LEASE LINE TO DETERMINE THE LIMITATION OF DEMOLITION
12
EXISTING STEEL STRUCTURE COLUMN TO REMAIN.
13
EXISTING LANDLORD PLUMBING CLEAN OUT TO REMAIN
2
2
11
GENERAL DEMOLITION NOTES
A
FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES IN WRITING PRIOR TO ONSET OF DEMOLITION.
B
DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH THE LOCAL BUILDING CODE AND LANDLORD'S STANDARD PROCEDURES.
C
EXERCISE EXTREME CAUTION IN DEMOLITION, COST OF REPAIR TO ANY ADJACENT CONDITIONS DAMAGED AS A RESULT OF THIS DEMOLITION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
D
ALL MATERIAL TO BE DISPOSED OF IS TO BE DONE BY THE CONTRACTOR OFF THE PROJECT SITE IN ACCORDANCE WITH L.L. REQUIREMENTS & LOCAL RESTRICTIONS UNLESS OTHERWISE NOTED HEREIN.
E
ALL AREAS SHALL BE KEPT IN A BROOM CLEAN CONDITION AT ALL TIMES.
F
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL THE EXPENSES
OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGE BY OPERATIONS IN CONNECTION WITH EXECUTION OF THE WORK . INACTIVE OR ABANDONED UTILITIES SHALL BE CAPPED IN ACCORDANCE WITH
LOCAL RESTRICTIONS, REMOVE INACTIVE SERVICES (PLUMBING, ELECTRICAL, MECHANICAL, ETC.) AS REQUIRED TO MAINTAIN OPERATION.
7
6
5
9
11
G
MAINTAIN COMPLETE SECURITY OF THE JOB SITE WHILE JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETE.
H
PROTECT ALL STRUCTURAL MEMBERS FROM DAMAGE, AND BRACE ALL EXISTING STRUCTURES AS NEEDED DURING THE DEMOLITION.
4
PHILADELPHIA, PA 19154
GENERAL CONTRACTOR SHALL REMOVE EXISTING WALL FINISHES AS SHOWN EXCEPT L.L. NEUTRAL PIER TILE. EXERCISE GREAT CARE IN NOT DAMAGING THE FIRE RATED
DRYWALL AT THE DEMISING WALLS. IF DAMAGED, G.C. SHALL REPAIR AS NECESSARY AND PREPARE THE SPACE TO RECEIVE NEW FINISHES PER FINISH SCHEDULE.
1455 FRANKLIN MILLS CIR,
2
SPACE 852A ~ 818 SQ. FT.
GENERAL CONTRACTOR SHALL REMOVE EXISTING NONBEARING PARTITION WALLS AS INDICATED. DISCONNECT AND REMOVE ALL EXISTING ELECTRIC, CAP OFF PLUMBING (IF
ANY) WITHIN REMAINING WALLS OR ABOVE CEILING, AS REQUIRED. PATCH AND REPAIR REMAINING WALL, CEILING, AND FLOOR SURFACES TO ACCEPT FINISHES AS INDICATED.
PHILADELPHIA MILLS
1
3
2
4
I
DO NOT CUT ON EXISTING STRUCTURAL WORK IN A MANNER RESULTING IN A REDUCTION OF LOAD CARRYING CAPACITY OR LOAD/DEFLECTION RATIO. NOTIFY LANDLORD REP. OF ALL STRUCTURAL
PROPOSED CUTS PRIOR TO EXECUTION TO OBTAIN APPROVAL.
J
IN ALL AREAS WHERE DEMOLITION CAUSES UNEVENNESS IN THE FLOOR SLAB, PERFORM THE NECESSARY WORK REQUIRED TO PROVIDE A SMOOTH SLAB PREPARED TO RECEIVE NEW FINISHES.
10
K
ANY EXISTING TO REMAIN FIRE ASSEMBLIES DAMAGED DURING DEMOLITION SHALL BE REPAIRED TO MEET ORIGINAL FIRE PROTECTION REQUIREMENT.
L
IT WILL BE THE GENERAL CONTRACTORS RESPONSIBILITY TO COORDINATE WITH LANDLORD ON-SITE OPERATIONS DIRECTOR AND TENANT BELOW, BEFORE BELOW SLAB WORK IS TO BE DONE.
13
12
1
4
1
8
10
DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
PROVIDE TEMPORARY CONSTRUCTION BARRICADE PRIOR TO COMMENCEMENT OF CONSTRUCTION,
DO NOT FASTEN TO MALL FINISH MATERIAL.
DO NOT ABANDON ANY UTILITIES OR MATERIALS WITHIN LEASE SPACE. REMOVE ALL UTILITY
LINES, ETC. BACK TO THE SOURCE AND CAP AS REQUIRED
TENANT'S CONTRACTOR WILL REPAINT AND/OR REPAIR LANDLORD PROPERTY (NEUTRAL PIERS,
BULKHEAD, REAR CORRIDOR, ETC.) DAMAGED DURING CONSTRUCTION.
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
DEMOLITION PLAN &
NOTES
D1.0
OF.1
LEASE DIMENSION
BALLAST/ TOTAL
FIXT.
WATT
3
14
*
EXIT LIGHT
*
EMERGENCY LIGHT
1
1
JUNO
ATLITE
SURELITE
IC1 LEDG4-3K- 1
14W-WH
PNLRU
CC-2
10%-100% DIMMING
1
1
10.8
14 WATT LED
3'-0"
NOTE:
14
FURNISHED
W/UNIT
UNIVERSAL
FURNISHED
W/UNIT
UNIVERSAL
120
120
90 MINUTE BATT.
BACKUP POWER
N/A
90 MINUTE BATT.
BACKUP POWER
N/A
N/A
N/A
N/A
N/A
RECESSED
FLUOR. LIGHT
FIXT. SEE
ELEC. DWGS.
ALL LIGHT FIXTURES ABOVE THE SERVICE,
PREPARATION, UTENSIL WASHING AND
FOOD STORAGE AREAS (INCLUDING THOSE
LIGHTS WITHIN STEAM TABLES,
REFRIGERATION UNITS, HOODS, AND
COOKING EQUIPMENT) SHALL BE SHIELDED
OR EQUIPPED WITH SHATTER-PROOF BULBS.
5
5
A
A
ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES.
3
ALL LAMPS IN FLUORESCENT LIGHT FIXTURES TO BE SYLVANIA UNLESS NOTED OTHERWISE.
2
INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S
RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS.
4
PROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA.
1
A1.1
109
EM
LIGHT
FIXTURES
AT WALK-IN
BELOW
1/
2"
E
RECESSED FLUOR. LIGHT
FIXTURE. SEE ELEC. DRAWINGS.
G
G
3'10
"
1/
2
"
10
3'1'-6"
E
G
G
G
G
G
2'-6 1/2"
G
G
TYP.
1'-10"
RECESSED
FLUOR. LIGHT
FIXTURE. SEE
ELEC. DWGS.
MALL
COMMON
AREA
107
101
105
106
105
2
A3.0
15'-0"
1
A3.1
111
100A
110
LINE OF
EXH. HOODS ABOVE
107
112
1
A3.0
1'-5"
SIGN
116
103
SALES
11"
7
LEASE LINE
4
A3.0
1
A3.0
TYP. 1'-3 1/2"
REFLECTED CLG. PLAN
FLOOR PLAN
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
16'-9 1/2"
10 1/2"
104
A4.0
MALL COMMON
AREA
117A
17'-11 1/2"
LEASE DIMENSION
ROOM FINISH SCHEDULE
MARK
DESCRIPTION
COUNTER GATE
N/A
1
EXISTING
METAL WALL PANELS
PAINT
GYP. BD. CLG
ACOUSTICAL CLG
N/A
CEILING
EXISTING
WALL COVERING
METAL WALL PANELS
FRP
CERAMIC TILE
N/A
WALLS
EXISTING
CERAMIC TILE
QUARRY TILE
EXISTING
BASE
N/A
FLOOR
CERAMIC TILE
AREA
DOOR SCHEDULE
SEE FINISH SCHEDULE, SHEET A-1.1 FOR
FINISH SPECIFICATIONS
SALES AREA
TYPE
FINISH
JAMB
-
-
-
JAMB
FINISH
-
JAMB
DETAIL
2
A1.0
WALL LEGEND
1
WALK-IN COOLER
EXTEND BEYOND
MIN. OF 6"
5/8" WATER
RESISTANCE
GYP. BD.
F.R.P.
SECTION
FIXTURE OR
EQUIPMENT.
LANDLORD NOTES:
EXISTING.
DEMISING
WALL STUDS.
AREA OF BLOCK'G.
SHOWN HATCHED.
F.F.
TYP. BLOCKING DETAIL
OPERABLE PART OF SOAP DISPENSER AND
PAPER TOWEL DISPENSER SHALL NOT BE
LOCATED MORE THAN 40”A.F.F. PER CBC
11B-603.5. SINK DEPTH SHALL NOT
EXCEED 6.5”
5/8" TYP. "X"
GYP. BD. AT
DEMISING
WALLS
(EXIST.)
F.R.P.
SINK WITH
LEVER HANDLE
FAUCET
F.R.T. PLYWOOD
(SHEET
BLOCKING)
SECURED TO
WALL STUDS.
2.1
QTB-1
SEE EQUIPMENT PLAN FOR
PLUMBING ACCESS. SCHEDULE
BLOCK'G.
PER DETAIL
THIS SHEET.
SECTION DEMISING AND
EXISTING INTERIOR WALLS
TYP. ELEV .AT HAND SINK
SCALE: AS NOTED
NO SCALE
SSM-1
WHITE PLASTIC
LAMINATE
3/4" PLYWOOD
SS-1
NEW DEMISING WALL, 6"
METAL STUDS @ 16" O.C.
=
WITH 5/8" TYPE 'X' GYP.
BD. ON TENANT SIDE.
6B
A-3.1
1
A1.1
SS-1
DOUBLE ACTING GATE DETAIL
2A
SCALE: 3" = 1'
A1.0
3
=
4" WALK-IN COOLER/FREEZER
INSULATED WALLS
2
2B
GATE ELEVATION
A1.0
NOT TO SCALE
GATE DETAILS
AS SHOWN
A1.0
CEILING. PER REFLECTED
CEILING PLAN.
PROVIDE SECOND TIER OF
SHELVING WHERE CLG.
SPACE ALLOWS.
HORIZONTAL
BLOCKING SUPPORT;
2 1/2" 16 GA METAL
STUDS BETWEEN
WALL STUDS.
EXIST.
DEMISING
WALL
2'-6"
4
A-1
BLOCK'G. PER DETAIL THIS
SHEET.
5
A-1
(5) 3 5/8" DPx2"-5/8"
X 16 GA. METAL
JOISTS EQUALLY
SPACED WITH 3/4"
PLYWD. SHEATHING.
EXTERIOR GRADE
SCALE: AS NOTED
BLOCKING DETAILS
3 5/8" MTL. JOISTS
FRP
6'-0"
3 5/8"DPx1-5/8"x16 GA.
MTL.JOISTS
QTB-1
2'-0"
ALL NEW WALL BOARD TO BE
WATER AND MOLD RESISTANT
3-5/8"X18 GA.
MTL. STUD
WALL BELOW
COND. AT WALL
SHOWN DOTTED
5/8" WATER
RESISTANT GYP. BD.
PAINT SEMI GLOSS
(WHITE)
FRP
(WALLS)
TYPICAL SHELVING ELEVATION
5/8" WATER
RESISTANT GYP. BD.
PAINT SEMI GLOSS
(WHITE)
FRP
103
SCALE: 1/4" = 1'-0"
1
A1.0
FLOOR PLAN,
CEILING
PLAN & NOTES
END JOISTS
3 5/8"DPx2"x16 GA.
NOTE:
SECTION: NON DEMISING WALL
EXTERIOR GRADE F.R.T.
3/4" PLYWD. SHEATHING
s/s CORNER GUARD
F.R.P.
3 5/8" M.S.
JOIST TO WALL
AT EACH STUD
IN WALL
3/4" PLYWOOD ADHERED TO
TO GYP. BD. "NO AIRSPACE"
METAL SHELVING PER
EQUIPMENT PLAN.
3/4" FIRE RATED
PLY-WOOD BLOCKING
FLUSH TO BACK SIDE
OF GYP.BD.
3" =1'-0"
G.C. TO PROVIDE
PIANO HINGES TO
LIFT UP PORTION OF
COUNTER TO
ACCESS GATE.
S/S TRIM WRAP AROUND
SCALE: AS NOTED
5/8" WATER
RESISTANCE GYP.
BD. INSTALL
FINISH PER
ELEVATIONS AND
NOTES.
A1.1
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
EXIST SALES AREA
WALL
FLIP-UP
COUNTER TOP
ABOVE.
2
EXISTING DEMISING WALL,
6" METAL STUDS @ 16"
=
O.C. WITH 5/8" TYPE 'X'
GYP. BD. ON TENANT SIDE.
SOAP DISP.
SEE DETAIL 2/A1.0
DOUBLE ACTING SURFACE
MOUNTING SPRING PIVOT
HINGE. BOMMER
BOM-7112-633
3-5/8" METAL STUDS @ 16"
= O.C. (12" O.C. AT LOW
WALLS) SEE DETAIL 2/A1.1
2
TOWEL DISP.
HARDWARE
2X (F.R.T.) WOOD BLOCKING AS REQ'D.
WITHIN NEUTRAL PIER
KITCHEN
2'-0"
MECHANICAL DIFFUSERS SEE M-1 FOR EXTENT OF MECHANICAL WORK
D
1
2.1
D
D
LINE OF
EXH.
HOODS
ABOVE
1'-4"
3
A3.0
MENU BOARDS
116
G
G
D
GENERAL CONTRACTOR SHALL COORDINATE WITH LANDLORD, PROVIDE AND INSTALL NEW NEUTRAL PIER TO MATCH EXISTING.
GENERAL CONTRACTOR WILL CONTACT THE LANDLORD'S SPRINKLER AND/OR FIRE ALARM CONTRACTOR FOR ALL ADDITIONS AND
REVISIONS TO THE EXISTING SYSTEM AT THE CONTRACTORS EXPENSE. SPRINKLER CONTRACTOR TO PROVIDE NECESSARY
DOCUMENTS FOR CONSTRUCTION AND PERMITTING UNDER SEPARATE COVER TO THE ARCHITECT, LANDLORD, AND GOVERNING
AUTHORITIES FOR APPROVAL PRIOR TO MAKING ANY MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM. COORDINATE
MODIFICATION SCHEDULE W/LANDLORD FIELD REP. SYSTEM IS TO BE FULLY CHARGED AND OPERATIONAL WHEN G.C. IS OFF SITE.
FINAL SPRINKLER LAYOUT TO BE DETERMINED BY SUBCONTRACTORS SHOP DRAWINGS.
G
2'-4"
D
E
QUARRY TILE
GENERAL CONTRACTOR SHALL REFURBISH ANY LANDLORD AREAS DAMAGED AT THE STOREFRONT TO A LIKE NEW CONDITION
(NEUTRAL PIERS, NEUTRAL BANDS, ETC.).INSTALL METAL CAP AT WALL END IN VISUAL ALIGNMENT TO NEUTRAL PIER AS REQUIRED
BY DESIGN CRITERIA. ADD NOTE: "GC TO COORDINATE FIELD APPROVAL FROM LANDLORD PRIOR TO FINAL INSTALLATION" - TYP
℄
114
2
A1.1
1
A3.1
E
G
NEW
EXH. HOOD
100A
106
2"
G
2.1
1/
117
8
A4.0
1'-1"
6'-10 1/2"
10
119
E
111
115
104
48'' G11
A1.1
105
8'-
E
P-2
TYP
103
2"
COORDINATE WITH OWNER AND SIGN VENDOR FOR NEW STOREFRONT SIGN INSTALL, ALL SIGNAGE TO BE APPROVED UNDER
SEPARATE SUBMISSION BY SIGN MANUFACTURER.
TYP.
4
108
7'-11"
2
A1.1
1/
116
110
110
11
GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL NEW CASEWORK AND COORDINATE WITH EQUIP. SUPPLIER, SEE SECTIONS ON
SHEET #A4.0 INSTALL ALL FINISHES AS SPECIFIED. ALL JOINTS IN AND AROUND CABINETS, SINKS, VENTILATOR, ICE BIN, ETC., TO
BE SEALED WITH CLEAR SILICONE SEALANT. PROVIDE BLACK PLASTIC WIRE WAY GROMMETS AT ALL DRILLED OPENINGS.
2'-2"
1
"
N
'-9
"
IO
16
-0 NS
'
18 IME
D
E
115
D
AS
GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL 5/8" TYP. "X" GYP. BD. CEILING/SOFFITS AND PAINT PER REFLECTED CLG.
PLAN, SECTIONS, AND ELEVATIONS.
118
LE
114
KITCHEN
108
2"
1/
U
EN
GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL 2'x4' LAY-IN CEILING SYSTEM AS INDICATED ON REFLECTED CEILING PLAN.
THE ENTIRE PERIMETER MUST BE SILICONE CAULKED WHERE GRID MEETS WALL.
106
106
2
A3.0
1'-8"
'' M
113
119
96
EXISTING LANDLORD STRUCTURE COLUMN NOT TO BE CHANGED OR MOVED.
WALK-IN
COOLER
105
1'-5"
CUT OUT FOR EQUIPMENT, VERIFY SIZE PRIOR TO CUTTING COUNTER TOP. SEE EQUIPMENT PLAN AND SCHEDULE ON SHEET A2.1
FOR MORE INFORMATION.
112
118
P.
QUARRY TILE FLOOR FINISH QT-1 TO BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR PER THE LATEST ADDITION OF
THE TILE COUNCIL OF AMERICA, INC. "HANDBOOK FOR CERAMIC TILE INSTALLATION" #F113-94 FOR INTERIOR FLOORS. PROVIDE
SANDED GROUT WITH ACRYLIC ADDITIVE; INSTALL PER MANUFACTURER'S SPECIFICATIONS OVER WATERPROOF MEMBRANE,
TY
110
118
NEW
EXH.
HOOD
E
E
9'-0" A.F.F.
NEW L.L. BULKHEAD HT.
GENERAL CONTRACTOR SHALL INSTALL 1-1/2" X 1-1/2" 16ga.S/S CORNER GUARDS OR END CAPS FROM FLOOR TO CEILING AT ALL
OUTSIDE CORNERS WITHIN THE PREP. ROOM. SCREW FASTEN AND SEAL WITH CLEAR SILICONE, TYP., AT ALL OUTSIDE CORNERS.
SEE DETAIL 6/A1.1
CONTRACTOR TO INSTALL REMOVEABLE CEILING TILE AND AIR GRILL TO CLOSE OFF AREA ABOVE WALK-IN COOLER
117A
114
D
E
E
E
11'-0" A.F.F.
GYP. BD CEILING
GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL STAINLESS STEEL PANELS OVER GYPSUM WALL BOARD FROM TOP OF QUARRY
TILE BASE TO BOTTOM OF HOOD, ALONG THE LENGTH OF THE HOOD AT BACK AND SIDES, AND OVER THE BACK SIDE OF THE FRONT
COUNTER LOW WALL BEHIND THE COOKING EQUIPMENT.
109
111
116
0"
108
E
SIGN
GENERAL CONTRACTOR SHALL PROVIDE & INSTALL F.R.P. ACCORDING TO THE MANUFACTURERS INSTRUCTIONS FOR APPLICATION
OVER GYPSUM DRYWALL.
117
SCP-1
3'-
107
E
113
D
E
"
106
110
10'-0" A.F.F.
SUSPEND CLG
E
1
'' G
WALL TILE, SOFFIT TILE AND BASES IN ROOMS WITH GYPSUM WALLBOARD WALLS SHALL BE THIN SET WITH ADHESIVE IN
ACCORDANCE WITH THE TILE COUNCIL OF AMERICA, INC. ANSI A1.008.5. NOTE: ALL WALL AND SOFFIT TILE SUPPLIED AND
INSTALLED BY GENERAL CONTRACTOR.
106
110
5
A3.1
3
6'-
E
E
30
105
1
2"
A
WALK-IN
FREEZER
4
A3.1
1/
A
2
GENERAL CONTRACTOR TO CONTINUE MALL FINISHES ON FLOOR FROM LEASE LINE TO FACE OF TOE KICK.
105
EX
D
11
104
0"
1
3'-
'' G
D
TE
101
5
E
E
8'-0"
3'3
D
A
48
LEASE
LINE
3'8
EN
C
JA
2"
2'- P.
TY
MENU BOARDS
116
GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL AT 16" O.C. & 3-5/8" METAL STUD PART. WITH 5/8" WATER RESISTANT
WALLBOARD ON BOTH SIDES OF WALL BETWEEN SALES/KITCHEN; TAPE AND SPACKLE; REMAINING INTERIOR WALLS TO HAVE 5/8"
WATER RESISTANT GYP. BD. BOTH SIDES, TAPE & SPACKLE.
T
1
P-2
4
A1.1
103
"
2'-
1'-
1'10
"
"
'-8
E
105
8'-
GENERAL CONTRACTOR SHALL PROVIDE F.R.T. BLOCKING AS INDICATED ON THE EQUIPMENT SCHEDULE OR AS NORMALLY
REQUIRED. ALL BLOCKING TO BE 3/4" F.R.T. PLYWOOD (MARINE GRADE IN WET AREAS). SCREW FASTEN BETWEEN METAL STUDS
AT NEW PARTITIONS AND FURRED WALLS. AT DEMISING WALLS, APPLY F.R.T. BLOCKING OVER 5/8" TYPE 'X' GYPSUM BD. COVER W/
5/8" GYP BD. AND FINISH WITH F.R.P. TILE. SECURE TO DEMISING WALL METAL STUDS. SEE BLOCKING DETAILS THIS SHEET.
N
D
2.1
3
3
A3.1
100
105
4'5
2
6"
114
1'-
N
A
2"
1/
1
7'-0" A.F.F.
GYP BD SOFFIT
T
8"
6"
103
P-2
1'-
101
118
114
WALK-IN
COOLER/ FREEZER
BELOW
A
4
5'-
2
100A
8'-6" A.F.F.
GYP. BD CEILING
LEASE
LINE
I
0"
'-1 ENS
4
2 IM
D
SE
A
LE
119
GENERAL CONTRACTOR SHALL VERIFY 1-LAYER OF 5/8" TYPE 'X' GYPSUM WALLBOARD AT ALL EXISTING DEMISING WALLS. ALL
DEMISING PARTITIONS ARE TO HAVE 5/8" TYPE 'X' GYPSUM WALLBOARD
FROM FINISH FLOOR TO UNDERSIDE OF DECK,
CONTINUOUS. PER #U425.
GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL AT 16" O.C. & 6" METAL STUD PART. WITH 5/8" TYPE 'X' WALLBOARD ON
TENANT SIDE FROM FINISH FLOOR TO UNDERSIDE OF DECK, CONTINUOUS. PER #U425. OTHER SIDE OF STUD TO INSTALLED BY
ADJACENT TENANT'S CONTRACTOR.
2
A3.1
TYP
ON
CONSTRUCTION NOTES
108
108
A
100
106
TYP
NOTE:
NO FRP PERMITTED IN FRONT-OF-HOUSE
(SALES) AREA WHERE EXPOSED TO
DIRECT CUSTOMER SIGHTLINES - TYP
1
A1.1
105
110
NOTES:
1
1
PHILADELPHIA, PA 19154
RECESSED DOWN
LIGHT
120
106
103
1455 FRANKLIN MILLS CIR,
*
RECESSED
10.8
SPACE 852A ~ 818 SQ. FT.
10.8 WATT LED
(620 LUMENS)
1
PHILADELPHIA MILLS
6G1MW LED
1
LEASE DIMENSION
LITHONIA
10%-100% DIMMING
LINE VOLTAGE DIMMING
39'-9 1/2"
20
120
105
TYP
ADJACENT TENANT
*
RECESSED
DOWN LIGHT
RECESSED
2'-6"
℄
10.8 WATT LED
(620 LUMENS)
100A
9'-4"
6G1MW LED
2
108
1'-9 1/2"
LITHONIA
15
9'-6"
12
N/A
LEASE DIMENSION
RECESSED CAN
LIGHT WALL WASH
N/A
℄
*
120
COLOR ‘DAYLIGHT’
PROVIDE ALL REQ'D.
HARDWARE
"
F15T8/D
UNDER
COUNTER
39
"
EM
PHILLIPS
18 INCH T8
DAYLIGHT WHITE
FLUORESCENT BULB
LEASE LINE
1/
2
EX
20
2GTL4 347 LP835
1
1/
2
G
LITHONIA
ELECTRONIC
℄
E
*
UNDER COUNTER
FLUORESCENT LIGHT
6
1
11
'-4
D
2x4 RECESS
TROFFER
120
5'-6"
℄
C
*
RECESSED
1/
2"
A
LED (39W) 4000
LUMEN
4'-6 1/2"
2'-6"
A1.0
PROVIDE ALL REQ'D.
HARDWARE
0-10V DIMMING
10%-100% DIMMING
6'-6"
BALLASTS
3'-5"
LAMPS/
FIXT.
11'-7"
REMARKS
3'-3"
VOLT
3'-5 1/2"
MTG.
7'-5"
LAMP
CATALOG
3'-10"
MANUFAC.
5'-9 1/2"
QTY.
13'-1 1/2"
4
5'-9 1/2"
DESCRIPTION
3
1'-6"
SYMBOL
2
4'-2"
TYPE NEW
1
3'-0 1/2"
LIGHTING FIXTURE SCHEDULE
FRAMING PLAN
1/2" =1'-0"
3
A1.0
DETAIL
1-1/2" =1'-0"
4
A1.0
DETAIL
1-1/2" =1'-0"
5
A1.0
A1.0
3-5/8" GA DEFLECTION
TRACK W/2-#10 SCREWS
TO EA. LOW FLUTE (12" O.C. MAX)
100 GYPSUM
1B
PROVIDE DOUBLE 3-5/8"X20 GA.
DIAGONAL BRACING @ 48" O.C.
W/ 3-#10 SCREWS EA. END.
2
1/2" DIA. ALL-THREAD
HANGER ROD FOR
CONNECTION BELOW
S.A.T. CLG. @
SEE R.C.P.
UNISTRUT P2867A BEAM
CLAMP EA. END
SALES
KITCHEN AREA
5/8" F.C. TYPE
GYP. BD. TO MIN. 6"
ABOVE FIN CLG. ON
SALES/KITCHEN SIDE
2
A
MENU BOARDS
/ EXHAUST HOODS
3 5/8" X 20 GA. RUNNER TRACK
(362T125-33) RAMSET AT 24"
O.C. "HILTI" BRAND MODEL
X-DNI 32 P8
ICC-ES REPORT #1663
INTERIOR PARTITION AND BRACING DETAIL
SCALE: NONE
2
A1.1
U.L. DESIGN NO. U425
NONBEARING WALL RATING - 1 HR.
WATER RESISTANCE
GYP. BD.
KITCHEN
1
A1.1
CONT. 12" HIGH
CEMENT BD. SAME
THICKNESS AS
GYP. BD.
F.R.P. TO
TOP OF BASE
QTB-1 BASE
NOTE:
TRIM AND SEAL COOLER TO
WALL BOTH VERTICALLY AND
HORIZONTALLY.
ADJACENT WALL CONSTRUCTION
FINISH SCHEDULE:
MANUFACTURER
TYPICAL
5
A1.1
FLOOR/WALL
WATER PROOFING
DETAIL THRU-OUT SPACE.
SCALE: N.T.S.
4
A1.1
ALL COVE BASES IN KITCHEN, WALK-IN COOLER/FREEZER, AND
* JANITOR'S
AREAS SHALL HAVE A MINIMUM OF 3/8" RADIUS COVE.
MARK
MATERIAL
SCP-1
CEILING TILE
USG INTERIORS
1.800.950.3839
USG CLEAN ROOM CLIMAPLUS, VINYL CLAD GYPSUM ROCK GRID 24"x48" CHICAGO METALLIC SERIES 830 ALUMINUM
WITH #41 WHITE FINISH. (CLASS A, FLAME SPREAD=<20, SMOKE DEVELOPED=5)
GYPSUM BOARD
USG INTERIORS
1.800.950.3839
5/8" TYPE 'X', SMOOTH FINISH, PAINTED PER REFLECTED CEILING PLAN
SALES AREA CEILINGS
GB-1
DAL-TILE
LYNDA GUNDLING
lynda.gundling@dal-tile.com
740-815-3693
SERIES: IDENTITY MATT WALL TILE
COLOR: MY 67 PARAMOUNT WHITE
SIZE: 8"X20"X3/8"
GROUT: #333 ALABASTER, 1/8" JOINT MIN.
(CLASS A, FLAME SPREAD=0, SMOKE DEVELOPED=0)
SALES AREA / COOKING
AREA
ALFALUX
HAMILTON PARKER
GABRIEL CANTRELL
GCANTRELL@HAMILTONPARKER.COM
614-358-7814/C:614-206-1443
STYLE: ALFALUX, TIMERSTONE-LOVE WOOD
COLOR: WENGE, NATURAL RETTIGFICATO
SIZE: 6"X24"
GROUT: TAUPE #185 CUSTOM BUILDING PRODUCT
(CLASS A, FLAME SPREAD=0, SMOKE DEVELOPED=0)
DAL-TILE
LYNDA GUNDLING
lynda.gundling@dal-tile.com
740-815-3693
STYLE: QUARRY TEXTURES
COLOR: ADOBE FLASH
SIZE: 6"X6" BASE" 6" H.
GROUT: MAPAE TERRA COTTA #37
(CLASS A, FLAME SPREAD=0, SMOKE DEVELOPED=0)
FLOOR TILE ALL AREAS
CORIAN
PRODUCT: TERRA COLLECTION
COLOR: DESIGNER WHITE (P/N 030784)
FINISH: SATIN
(CLASS A, FLAME SPREAD=<25, SMOKE DEVELOPED=<25)
COUNTERTOPS
COLOR:DESIGNER WHITE D354
FINISH: MATTE
(CLASS A, FLAME SPREAD=30, SMOKE DEVELOPED=15)
COLOR:MONTANA WALNUT 7110K-78
FINISH: FINE GRAIN (CLASS A, FLAME SPREAD=30, SMOKE DEVELOPED=15)
T-1
T-2
PORCELAIN TILE
PORCELAIN TILE
QT-1
QUARRY FLOOR TILE
QTB-1
*
S-1
SOLID SURFACE
MATERIAL
PL-1
PLASTIC LAMINATE
WILSONART
1.800.433.3222
PL-2
PLASTIC LAMINATE
WILSONART
1.800.433.3222
MT-1
STAINLESS STEEL
LOCAL SUPPLIER
MT-2
STAINLESS STEEL
LOCAL SUPPLIER
DESCRIPTION
GRAPHIC SCHEDULE
KITCHEN CEILING
FRONT COUNTER FACE
INSIDE FACE OF CABINETS
OUTSIDE FACE OF CABINETS/OFFICE
DESK
SMOOTH 18-20 GAUGE, INSTALL PER SMACNA STANDARDS. ALL EDGES TO BE HEMMED, ALL SEAMS TO BE WELDED
AND GROUND SMOOTH.
(CLASS A, FLAME SPREAD=0, SMOKE DEVELOPED=0)
BEHIND GRILL AND FRYER
BRUSHED, 18-20 GAUGE, INSTALL PER SMACNA STANDARDS. ALL EDGES TO BE HEMMED, ALL SEAMS TO BE WELDED
AND GROUND SMOOTH. (CLASS A, FLAME SPREAD=0, SMOKE DEVELOPED=0)
FRONT COUNTER BASE
WALL COVERING TO BE PURCHASED
AND INSTALLED BY G.C. CONTACT
ONMOVA SOLUTIONS.
CUSTOM WALL
COVERING
ONMOVA SOLUTION
CUSTOM WALL VINYL WALL COVERING
(CLASS C, FLAME SPREAD=<200, SMOKE DEVELOPED=450)
P-1
PAINT
SHERWIN WILLIAMS
EXTRA WHITE - SW7006 HIGH GLOSS LATEX ENAMEL
SOFFITS, CEILING GRID,
DOOR FRAME, DOORS
P-2
PAINT
SHERWIN WILLIAMS
PAINT TO MATCH EXISTING LANDLORD PAINT COLOR
LANDLORD BULKHEAD
FRP
FIBERGLASS
REINFORCED
POLYESTER PANELS
MARLITE
1.216.343.6621
P-100 WHITE. INSTALL PER MANUFACTURER'S INSTRUCTIONS. PROVIDE TOP AND VERTICAL MOLDING AS REQUIRED,
CAULK ALL EDGES FOR WATER TIGHT SEAL. (CLASS C, FLAME SPREAD=<200, SMOKE DEVELOPED=450)
KITCHEN WALLS
WC-1
SUPPLY INSTALL
LOCATION/REMARKS
NOTE:
5. ALL MATERIALS USED FOR INTERIOR FINISHES AND TRIM SHALL BE CLASSIFIED IN ACCORDANCE WITH ASTM E84.
1. IT IS THE CONTRACTORS RESPONSIBILITY TO FURNISH AND INSTALL ALL FINISHES.
I. CLASS A: FLAME SPREAD 0-25; SMOKE-DEVELOPED 0-450
2. ALL ITEMS SHOWN AS EXISTING ARE TO BE VERIFIED, PATCHED, AND REPAIRED BY CONTRACTOR.
3. SEE CONSTRUCTION NOTES AND SPECIFICATIONS FOR GROUT INSTALLATION PROCEDURES.
II. CLASS B: FLAME SPREAD 26-75; SMOKE-DEVELOPED 0-450
4. ALL FINISHES TO BE MIN. CLASS "C".
III.CLASS C: FLAME SPREAD 76-200; SMOKE-DEVELOPED 0-450
QTY MARK DESCRIPTION
G.C.
SCALE: 1 1/2" = 1'-0"
BASE AS
APPLICABLE
FRANCHISEE
COOLER TRIM DETAIL
A1.1
SALES
ELECTRIC SIGNS
STAINLESS STL. CLOSURE, 2" X 2".
SET INTO SEALANT AND FASTEN @ 12"
O.C. INSTALL FROM TOP OF BASE TO
TOP OF WALK-IN.
6
SCALE: 1 1/2" = 1'-0"
VINYL INTERIOR MENU
SIGNS
BOARDS
WALL OF WALK-IN
COOLER/FREEZER
6"
BASE & W.P
MEMBRANE
FACE OF WALL SEE FLOOR PLAN
WATER PROOF
MEMBRANE SHALL
BE LATICRETE 9325
OR EPOXY OR
NEOGUARD
MEMBRANE OR
MER-KRETE
HYDRO-GUARD
2000
S.S. DETAILS
SEE SALES AREA
FINISHES
12"
1"
PLAN VIEW
16 GA.S/S END WALL CAP
GUARD, SET IN PLACE W/
STR'L ADHESIVE &
SILICONE ALL EDGES
G.C.
SCALE: 3/4" = 1'-0"
2"
16 GA S/S ANGLE CORNER
GUARD, SET IN PLACE W/
STR'L ADHESIVE &
SILICONE ALL EDGES
FRANCHISEE
TYP. WALL SECTION AT
EXIST. DEMISING WALL
3
A1.1
FIN. FLOOR (SEE
A-1 FOR TYPE)
2"
QTB-1 BASE SALES AND
KITCHEN AREA,
SCALE: 1 1/2" = 1'-0"
1. Wall Assembly — The fire rated gypsum wallboard/stud wall assembly shall be
constructed of the materials and in the manner specified in the individual U300 or U400
Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the
following construction features:
A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood
studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 3-5/8 in.
wide and spaced max 24 in. OC.
B. Gypsum Board* — Nom 5/8 in. thick gypsum wallboard, as specified in the individual Wall
and Partition Design. Diam of opening is 1-1/2 in. larger than the outside diam of pipe.
2. Through-Penetrant — One metallic pipe, conduit or tubing to be centered within the
firestop system. An annular space of 3/4 in. is required within the firestop system. Pipe,
conduit or tubing to be rigidly supported on both sides of wall assembly. The following types
and sizes of metallic pipes, conduits or tubing may be used:
A. Steel Pipe — Nom 12 in. diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Conduit — Nom 6 in. diam (or smaller) electrical metallic tubing or steel conduit.
C. Copper Tubing — Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing.
D. Copper Pipe — Nom 6 in. diam (or smaller) Regular (or heavier) copper pipe.
3. Fill, Void or Cavity Material* — Sealant — Min 5/8 in. thickness of fill material applied
within annulus, flush with both surfaces of wall assembly.
3M COMPANY — FB-2000+
2"
EXISTING
SLAB
SECTION A-1
HOOD HANGING DETAIL
6"
EXISTING STEEL STUDS:
3 5/8" IN. WIDE (MIN.)
1-1/4 IN. LEGS, 3/8 IN.
RETURN, FORMED OF 25
MSG (MIN.) GALV STEEL MAX
STUD SPACING 24 IN. O.C.
SPACE 852A ~ 818 SQ. FT.
3 5/8" x 20 GA. MTL. STUDS
(362S162-33) @ 16" O.C. TO
STRUCTURE ABOVE,
(1CC ER-4943P)
OR EQUAL.
EXIST.FLOOR & CEILING
RUNNER: 20 MSG (MIN.) GALV.
STEEL 1 IN. HIGH,
RETURN LEGS 3-5/8 IN.
WIDE (MIN.) ATTACHED TO
FLOOR AND CEILING WITH
FASTENERS 24 IN. O.C.
1A
PHILADELPHIA MILLS
100
A
5/8" F.C. TYPE "X"
GYP. BD. 6" ABV.
SALES AREA
FINISH CEILING
WALLBOARD: 5/8 IN. THICK,
TYPE X, 4 FT. WIDE, ATTACHED
TO STEEL STUDS AND FLOOR
AND CEILING TRACK WITH 1 IN.
LONG, TYPE S SELFTAPPING STEEL SCREWS
SPACED 8 IN. O.C. ALONG
EDGES OF BOARD AND 12
IN. O.C. IN THE FIELD OF
THE BOARD. JOINTS
ORIENTED VERTICALLY AND
STAGGERED ON OPPOSITE
SIDES OF THE ASSEMBLY.
U.S. GYPSUM CO.-TYPE 'C'
JOINT TAPE & COMPOUND
VINYL, DRY OR PREMIXED
JOINT COMPOUND, APPLIED
IN TWO COATS TO JOINTS
AND SCREW HEADS; PAPER
TAPE, 2 IN. WIDE, EMBEDDED
IN FIRST LAYER OF COMPOUND
OVER ALL JOINTS. AS AN
ALTERNATE, NOMINAL 3/32 IN.
THICK GYPSUM VENEER
PLASTER MAY BE APPLIED
TO THE ENTIRE SURFACE
OF CLASSIFIED VENEER
BASEBOARD, JOINTS
REINFORCED.
UNI-STRUT P1001
EXISTING
METAL FRAMING
DECK
PHILADELPHIA, PA 19154
EXISTING FLOOR & CEILING
RUNNER: 20 MSG (MIN.) GALV.
STEEL 1 IN. HIGH,
RETURN LEGS 3-5/8 IN.
WIDE (MIN.) ATTACHED TO
FLOOR AND CEILING WITH
FASTENERS 24 IN. O.C.
EXISTING
SEAL TO DECK
July 29, 1995
F Rating — 1 Hr
T Rating — 0 Hr
P106 PLATE
STEAL BEAM /
TRUSSES
6"
EXISTING
DECK
System No. W-L-1084
1455 FRANKLIN MILLS CIR,
EXISTING
FILL VOIDS WITH
U.L. #HW-S-0009 (1-HR)
L2X2X20 GAX1'-0"
W/ 3-#10 SCREWS
TO UNDERSIDE OF
EXISTING MTL.
DECK.
1
G1
STOREFRONT SIGN REFERENCE CHARLEY'S
STANDARD SIGNAGE REQUIREMENTS AND MALL
CRITERIA
X
1
G1
INTERNALLY ILLUMINATED LIGHT BOX
(30"Wx39"H) "CHICKEN PHILLY & FRIES"
X
X
1
G2
INTERNALLY ILLUMINATED LIGHT BOX
(48"Wx39"H) "GOURMET FRIES"
X
X
0
G4
INTERNALLY ILLUMINATED LIGHT BOX
(21"Wx39"H) "BREAKFAST"
X
X
0
G6
X
X
1
G11
INTERNALLY ILLUMINATED LIGHT BOX
(30"Wx39"H) "PHILLY STEAKS"
X
X
0
G12
INTERNALLY ILLUMINATED LIGHT BOX
(30"Wx39"H) "#1 CHEESETEAKS IN THE WORLD"
X
X
1
MG1
INTERNALLY ILLUMINATED MENU BOARDS
(96"Wx39"H)
X
X
0
SG1
BACK DOOR SIGNAGE (VERIFY WITH LANDLORD)
X
X
2
SG5
"EMPLOYEES MUST WASH HANDS BEFORE
RETURNING TO WORK"
X
X
1
VG1
"COOLER KEEP DOOR CLOSED"
X
X
1
VG2
"FREEZER KEEP DOOR CLOSED"
X
X
INTERNALLY ILLUMINATED LIGHT BOX
(30"Wx39"H) "CHICKEN TERIYAKI & CHICKEN
BUFFALO"
X
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
FINISH SCHEDULE AND
DETAILS
A1.1
120
-
0.36
-
C/P
-
-
-
-
-
0.10
-
-
-
-
-
-
REMARKS
B.T.U.H. OWNER G.C. OWNER G.C.
E1
2
X
BY OWNER
BY OWNER
E2
2
X
-
-
E3
2
X
BY OWNER
BY OWNER
CASH REGISTER
120
-
-
0.10
-
-
-
-
-
-
X
X
E4
2
X
BY OWNER
BY OWNER
REGISTER PRINTER
120
-
-
0.36
-
-
-
-
-
-
X
X
E5
2
X
-
-
PASEO 20WATT AMPLIFIER
120
-
-
0.10
-
-
-
-
-
-
X
X
E6
1
X
-
-
CEILING MOUNT SPEAKER
120
-
-
0.10
-
-
-
-
-
-
X
X
E7
2
X
BY OWNER
BY OWNER
LCD ORDER MONITOR
120
-
-
0.36
-
-
-
-
-
-
X
E8
2
X
BY OWNER
BY OWNER
LCD ORDER MONITOR BRACKET
-
-
-
-
-
-
-
-
-
-
X
E10
1
X
BY OWNER
BY OWNER
PHONE
120
-
-
-
-
-
-
-
-
-
X
X
PHONE AND FAX MACHINE MAY BE COMBINATION UNIT.
E11
1
X
BY OWNER
BY OWNER
FAX
120
-
-
-
-
-
-
-
-
-
X
X
PHONE AND FAX MACHINE MAY BE COMBINATION UNIT.
E12
1
X
BY OWNER
BY OWNER
TV/DVD COMBINATION UNIT
120
-
-
-
-
-
-
-
-
-
X
X
INCLUDED IN NEW STORE OFFICE SUPPLY LIST.
E13
1
X
BY OWNER
BY OWNER
COMPUTER (CPU) KEYBOARD, AND MOUSE
120
-
-
-
-
-
-
-
-
-
X
X
INCLUDED IN NEW STORE OFFICE SUPPLY LIST.
E14
1
X
BY OWNER
BY OWNER
COMPUTER MONITOR
120
-
-
-
-
-
-
-
-
-
X
X
INCLUDED IN NEW STORE OFFICE SUPPLY LIST.
E15
1
X
BY OWNER
BY OWNER
COMPUTER PRINTER & PRINTER CABLE
120
-
-
-
-
-
-
-
-
-
X
X
H1
2
X
CAPTIVE AIR
CUSTOM
TYPE 1 EXHAUST HOOD W/ SELF-CONTAINED M/U
AIR, ROOF CURB, AND ROOFTOP EXHAUST FAN.
120
-
0.1
-
-
-
-
-
-
-
X
H2
1
X
ANSUL
R-102
HOOD FIRE SUPPRESSION SYSTEM
120
-
0.1
-
-
-
-
-
-
-
X
H3-1
1
X
STANDARD
4A: 60B: C
FIRE EXTINGUISHER PER LOCAL CODE
-
-
-
-
-
-
-
-
-
-
H3-2
1
X
K-CLASS
60B: C
FIRE EXTINGUISHER PER LOCAL CODE
K1-1
1
X
MIGIKITCH'N
MKG72
GAS GRILL, 180,000 BTU, LOW PROFILE, 72"
GRIDDLE PLATE W/ CORD & PLUG FOR CONTROLS
K 1-2
1
X
DORMONT
1675 KI T 2S- 48
GAS CONNECTION HOSE, QUICK DISCONNECT
-
-
120
1
-
-
1.32
-
X
X
G.C. TO FURNISH AND INSTALL CAT 5 AND VGA CABLES
X
X
PROVIDE (2) TILLS
M11
P11-1
P11-2
X
X
X
X
-
-
-
-
-
-
-
-
-
-
-
-
-
180,000 BTU
X
X
-
-
-
-
-
-
-
X
X
X
X
S3
T18
P6-2
P6-1
SAFETY RESTRAINT
-
-
-
-
-
-
-
-
-
-
X
X
K 1-4
1
X
BY G.C.
BY G.C.
GRILL STOP. 2" GALV. PIPE W/ FLANGE
-
-
-
-
-
-
-
-
-
-
X
X
K2-1
1
X
PITCO
SG-14
GAS FRYER W/ FILTER
120
1
-
-
-
C/P
-
-
-
110,000 BTU
K 2-2
1
X
BY G.C.
BY G.C.
SAFETY RESTRAINT
-
-
-
-
-
-
-
-
-
-
K 2-3
1
X
DORMONT
16500 KI T 2S- 48
GAS CONNECTOR KIT
-
-
-
-
-
-
-
-
-
-
X
X
K3
1
X
PITCO
SEBNB14
DUMP STATION
120
1
6.9
0.83
-
-
-
-
-
-
X
X
K4
1
X
HATCO
K3 MOUNTED HEAT LAMP
120
1
6.9
0.83
-
-
-
-
-
-
X
X
X
LINCOLN
208
1
27.0
6.0
-
-
-
-
-
X
X
X
SEE MECHANICAL DWGS.
3'-0 1/2"
S15
M4
K8
INPINGER 1301
CONVEYOR TOASTER
NEMA 6-50P
COORDINATE W/ LOCAL FIRE MARSHALL FOR LOCATION
S6
P7-1
81290
HOT TOPPING
S8
T15
soffit above
3'-
F2
3
2"
1/
S12
P9-2
P10
E15
E11
P3
existing
landlord
cleanouts
C/P
-
-
-
-
X
X
-
-
-
-
-
-
-
-
-
-
X
X
-
-
-
-
-
-
-
-
-
-
X
X
115
1
4.9
-
-
C/P
-
-
-
-
X
X
M5
M4
NORLAKE
KOLD LOCKER
K9
2
X
TRUE
T SSU- 27- 12M - C
WALK-IN FREEZER W/FLOOR AND SELF CONTAINED
CONDENSER
REFRIGERATED SANDWICH TABLE W/ CASTERS
(27 IN)
K10
1
X
TRUE
T SSU- 48- 18M
REFRIGERATED SANDWICH TABLE W/ CASTERS
(48 IN)
115
1
8.6
-
1/3
C/P
-
-
-
-
X
X
K11
1
X
CRATHCO
D-25
2 - 5 GALLON BOWL LEMONADE DISPENSER
120
1
5.5
0.64
-
C/P
-
-
-
-
X
X
K12-2
LIPTON
X
ICED TEA URN
X
BY OWNER
BY OWNER
18"(D)x30"(W)x24"(H) S.S. FLOOR SHELVING
(2 TIER)
K14
1
X
ROBOT COUPE
R2N ULTRA
FOOD PROCESSOR
K15
1
X
EASY LETTUCEKUTTER
LETTUCE CUTTER
P 1-1
1
X
ICD 2300
POST MIX DISPENSER, ICE BIN W STAND (CB2323)
1
1
X
X
NEMCO
LANCER
COKE
COKE
COKE
CARBONATOR & WATER FILTER PACKAGE
COKE
BAG IN BOX W/ SHELVES & LINES
120
1
15
1.8
-
C/P
-
1/4"
-
-
-
X
K12-2
96
''
P5
M
EN
K9
U
E7
X
T17
E8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
X
X
120
1
7.0
-
-
C/P
-
-
-
-
X
X
-
-
-
-
-
X
X
C/P
-
-
1" I.D.
-
X
-
-
-
-
-
-
-
-
-
120
1
3.5
-
-
120
120
1
1
7.0
6.2
-
-
-
C/P
-
-
1/2"
1/2"
-
-
-
-
-
-
X
X
-
-
-
-
-
-
-
X
7-PS-60
WALL MOUNTED HAND SINK
-
-
-
-
-
-
1/2"
1/2"
2"
-
X
X
ADVANCE
DI-1-5
DROP-IN HAND SINK
-
-
-
-
-
-
1/2"
1/2"
2"
-
X
X
X
ADVANCE
9-61-18-24L
(1) COMPARTMENT PREP SINK
-
-
-
-
-
-
1/2"
1/2"
-
X
X
1
X
T&S BRASS
B-0231
FAUCET
-
-
-
-
-
-
-
-
-
-
X
X
P 7-1
1
X
ADVANCE
9-3-54-18RL
(3) COMPARTMENT SINK W/ DRAINBOARDS
-
-
-
-
-
-
1/2"
1/2"
2"
-
X
X
P 7-2
1
X
T&S BRASS
B-0133-01
PRE-RINSE ASSEMBLY
-
-
-
-
-
-
-
-
-
-
X
X
P 7-3
1
X
T&S BRASS
B-0156
ADD-ON FAUCET
-
-
-
-
-
-
-
-
-
-
X
X
P8
1
X
MANITOWOC
I-450
ICE MAKER
115
1
13.2
-
-
C/P
1/2"
-
-
-
X
X
P 9-1
1
X
MANITOWOC
B-570
ICE BIN
-
-
-
-
-
-
-
-
3/4" I.D.
-
X
X
-
TOP KIT
-
-
-
-
-
-
-
-
-
-
X
X
WATER FILTER
-
-
-
-
-
-
-
-
-
-
X
X
EVERPURE COLDRINK 2 7CLM EV9327-12 WATER FILTER
-
-
-
-
-
-
-
-
-
-
X
X
P4
1
X
ADVANCE
P5
1
X
P 6-1
1
P 6-2
-
1-1/2" I.D.
1
X
MANITOWOC
P 10
1
X
ARCTIC PURE
P 10-1
1
X
P 11-1
1
X
ADVANCE
9-OP-20
MOP SINK
-
-
-
-
-
-
1/2"
1/2"
3"
-
X
X
P 11- 2
1
X
ADVANCE
K-240
SERVICE SINK FAUCET
-
-
-
-
-
-
-
-
-
-
X
X
P 14
1
X
A.O. SMITH
DEL-50
WATER HEATER
480
3
-
12
-
-
1" I.D.
-
X
X
NEW EXIST.
MF G
MODEL
OWNER
G.C.
INSTALL
OWNER
G.C.
I T EM
REMARKS
XPRESSNAP INTROFOLD NAPKIN
X
X
RECESSED IN COUNTER
CONDIMENTS HOLDER
X
X
RECESSED IN COUNTER
CUP DISPENSER
X
X
RECESSED IN COUNTER
SOAP DISPENSER
X
X
INCLUDED IN SMALLWARES PACKAGE
PAPER TOWEL DISPENSER
X
X
INCLUDED IN SMALLWARES PACKAGE
MB2720IC
SAFE
X
X
SEE DET 8/A-4.0 FOR SAFE ANCHORING
Weight: 186 lbs
EXC-700
COAT RACK
X
X
M1
2
X
M2
3
X
TORK
VOLLRATH
M3
6
X
DISPENSE-RITE ADJ-2
M4
2
X
M5
2
X
M6
1
X
WILSON
M7
1
X
EXCELL
BOBRICK
DESCRI P T I ON
SUPPLY
N4 SYSTEM
78710
B-4112
AW MENDENHALL GPT74C
M8
1
X
BY OWNER
BY OWNER
24" x 36" BULLETIN BOARD
M9
1
X
BY OWNER
BY OWNER
M10
1
X
MAGNAGRIP
M11
1
X
RUBBERMAID
M12
0
SERTEK
S1
0
BY OWNER
12 X 24
S3
4
X
NEXEL
18 X 36
S5
1
X
NEXEL
18 X 42
S6
2
X
NEXEL
18 X 48
MARK QT Y .
WORK TABLES
MARK QT Y
SP ECI F I CAT I ON
3/4" IN 3/4" OUT
INCLUDED W/ NEW STORE OFFICE
SUPPLY LIST
NEW EXIST.
E7
E2
E5
1/2" FW
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
MODEL
DESCRI P T I ON
SUPPLY
OWNER
G.C.
OWNER
X
6" CASTERS W/ RESTRAINTS. SEE CASTER
RESTRAINT DETAIL, SHEET P-2.
KMS-2436
WORK TABLE W/ 5" BACKSPLASH, CASTERS,
& 2 SHELVES 24"X36"
X
X
STANDARD HEIGHT
ADVANCE
KMS-2442
WORK TABLE W/ 5" BACKSPLASH, CASTERS,
& 2 SHELVES 24"X42"
X
X
STANDARD HEIGHT
X
ADVANCE
KMS-2448
WORK TABLE W/ 5" BACKSPLASH, CASTERS,
& 2 SHELVES 24"X48"
X
X
STANDARD HEIGHT
1
X
ADVANCE
KMS-2472
WORK TABLE W/ 5" BACKSPLASH, CASTERS,
& 2 SHELVES 24"X72"
X
X
STANDARD HEIGHT
T 22
1
X
ADVANCE
KMS-3048
WORK TABLE W/ 5" BACKSPLASH, CASTERS,
& 2 SHELVES 30"X48"
X
X
TOASTER TABLE
F1
1
X
BY G.C.
BY G.C.
COUNTER BASE W/ ADJUSTABLE SHELVES
W/OUT DOORS
X
X
SEE MILLWORK DWGS SHEET A4.0
X
X
INSTALL CABINET DOORS AT BACK COUNTERS
X
X
48" WIDE MAX.
X
ADVANCE
-
T 15
1
X
ADVANCE
T 16
1
X
T 17
1
T 18
018
INCLUDED IN SMALLWARES PACKAGE
1992 GREY
MOP HOLDER
X
X
INCLUDED IN SMALLWARES PACKAGE
CUSTOM
TOASTER OVEN CART
X
X
SINGLE WALL MOUNTED SOLID STAINLESS
STEEL SHELF
WALL MOUNTED (REGULAR ERECTA SHELF )
W/ 2 SHELVES EACH
X
X
EQUIPMENT NOTES:
X
X
1. ALL EQUIPMENT SHALL BE PURCHASED BY THE OWNER AND INSTALLED BY THE GENERAL CONTRACTOR. SIGNAGE TO BE INSTALLED BY SIGN VENDOR.
WALL MOUNTED (REGULAR ERECTA SHELF )
W/ 2 SHELVES EACH
X
X
WALL MOUNTED (REGULAR ERECTA SHELF )
W/ 2 SHELVES EACH
X
X
18 X 30
5-TIER FLOOR SHELVING (WITH 7' POLES)
X
X
S9
1
X
NEXEL
18 X 36
5-TIER FLOOR SHELVING (WITH 7' POLES)
X
X
S11
2
X
NEXEL
18 X 48
5-TIER FLOOR SHELVING (WITH 7' POLES)
X
X
S12
4
X
NEXEL
18 X 60
5-TIER FLOOR SHELVING (WITH 7' POLES)
X
X
S13
1
X
KEL MAX
DR36188
DUNNAGE RACK (18 x 36)
X
X
S1 5
1
X
KEL MAX
DR48188
DUNNAGE RACK (18 x 48)
X
X
S16
1
X
KEL MAX
DR60188
DUNNAGE RACK (18 x 60)
X
X
REMARKS
X
1
MAGNETIC KNIFE HOLDER
NEXEL
G.C.
GRILL TABLE (30"x48")
T1
X
X
FIRE EXTINGUISHER NOTES
INSTALL
X
2
F1
SCALE: 1/4" = 1'-0"
WALL MOUNTED FIRST AID KIT
S8
E4
E3
X
X
INCLUDED W/ NEW STORE OFFICE
SUPPLY LIST
E8
E1
EQUIPMENT PLAN
SP ECI F I CAT I ON
MF G.
H3-2
K11
X
X
MILL
WORK
I T EM
AR-10000
K10
6'-0"
P1-2
PROVIDED BY COCA COLA
K1-4
48'' G11
K1-1
P1-1
PROVIDED BY COCA COLA
-
NUC02
K1-3
M2
X
T22
E6
T1
K4
K5
S
H1
K1-2
K2-3
M1
PROVIDED BY COCA COLA
X
-
X
E3
K3
K2-2
PROVIDED BY COCA COLA
X
X
K2-1
E4
E5
-
2
E1
E2
X
-
S3
K6
INCLUDED IN EQUIPMENT PACKAGE
X
90LB C02 TANK
P3
P 9-2
MISCELLANEOUS
L T B103
AUTOMATIC ICED TEA BREWER
0
P2
SHELVING
L T B103
K13
P 1-2
P LUMBING E QUIPMENT
1
LIPTON
X
S3
2
M3
1
F3
E12
1
X
K14
M6
M8
E10
M9
'' G
1
E13
30
K8
K15
P2
-
KOLD LOCKER
T16
M7
E14
H2
P10-1
H3-1
60"
P9-1
1
1
NORLAKE
S12
3'0"
8.3
X
36"
K7
3
1
S13
30"
6" PIPE LENGTH, PAINT-ALUMINUM
120
K7
60"
S8
P7-2
S6
X
WALK-IN COOLER W/FLOOR AND SELF CONTAINED
CONDENSER
K12-1
S12
P7-3
2
SERVER
S16
M5
P8
-
48"
P4
COORDINATE W/ LOCAL FIRE MARSHALL FOR LOCATION
'' G
X
K12-1
S9
X
X
S11
"
BY G.C.
1
S11
S5
3'-3
BY G.C.
60"
P14
WALL MOUNT
SEE MECHANICAL DWGS.
X
K6
S12
36"
X
1
1
MATCH COLOR OF CEILING
X
K 1-3
K5
GOOSENECK MICROPHONE (13" FLEX)
F2
1
X
BY G.C.
BY G.C.
WALL BASE CABINETRY, W/ LAMINATE
DOORS & CORIAN TOP
F3
1
X
BY G.C.
BY G.C.
MANAGERS WORKTOP
1
CLASS ABC FIRE EXTINGUISHER: EXTINGUISHERS SHALL BE
CONSPICUOUSLY LOCATED AND READILY ACCESSIBLE. THE TOP OF
THE EXTINGUISHER SHALL NOT BE MORE THAN 5 FT. ABOVE THE
FLOOR AND THE BOTTOM OF THE EXTINGUISHER SHALL NOT BE LESS
THAN 4 INCHES ABOVE THE FLOOR. EXTINGUISHERS SHALL BE
INSTALLED IN ACCORDANCE WITH CLASSIFICATION, RATING, AND
DISTRIBUTION REQUIREMENTS OF NFPA 10. [NFPA 1: 13.6.1.2]
2
CLASS K FIRE EXTINGUISHER:
CLASS K FIRE EXTINGUISHERS SHALL BE PROVIDED FOR HAZARDS
WHERE THERE IS A POTENTIAL FOR FIRES INVOLVING COMBUSTIBLE
COOKING MEDIA. [NFPA 10:4.3.2]
LANDLORD NOTES:
2. FOOD SERVICE AND BEVERAGE DISPENSING EQUIPMENT SHALL COMPLY W/ NSF REQUIREMENTS AND REQUIREMENTS OF LOCAL HEALTH OFFICIALS HAVING JURISDICTION.
3. INSTALLATION AND CONNECTION OF ALL FOOD SERVICE EQUIPMENT IS TO BE PERFORMED BY THE GENERAL CONTRACTOR UNLESS OTHERWISE INDICATED.
4. SHELVING UNITS SHALL BE ASSEMBLED AND SET IN PLACE BY THE GENERAL CONTRACTOR.
PROVIDE "GREEN
WALK-INS
PROVIDE "GREEN
WALK-INS
PROVIDE "GREEN
WALK-INS
PROVIDE "GREEN
WALK-INS
KOTE" SHELVING IN
5. FOOD SERVICE EQUIPMENT REQUIRING AN ELECTRICAL CONNECTION IS TO BE FURNISHED W/ CORD AND PLUG UNLESS OTHERWISE INDICATED.
KOTE" SHELVING IN
6. VERIFY THE ELECTRICAL AND MECHANICAL REQUIREMENTS OF FOOD SERVICE EQUIPMENT PRIOR TO INSTALLATION.
KOTE" SHELVING IN
KOTE" SHELVING IN
PHILADELPHIA, PA 19154
GOOSENECK MICROPHONE (13" FLEX)
WASTE
1455 FRANKLIN MILLS CIR,
20
C.W. H.W.
SPACE 852A ~ 818 SQ. FT.
1
CONN.
PHILADELPHIA MILLS
120
H.P.
ELECTRICAL PANELS
CASH REGISTER WITH EXTRA TILL
AMP. KW.
60"
/
0
DESCRI P T I ON
SUPPLY INSTALL
48''
MECH
VOLTS
MODEL
PLUMBING
48
KI TCHEN EQUI PME NT
MF G.
ELECTRICAL
48''
EL E CT RONIC COMPONE NT E QUIPMENT
MARK QT Y . NEW EXIST.
SP ECI F I CAT I ON
60"
I T EM
30"
XX
7. SINKS SHALL BE PROVIDED W/ DRAIN TAILPIECES AND FITTINGS. THE GENERAL CONTRACTOR SHALL PROVIDE SHUT-OFF VALVES, SUPPLIES AND TRAPS NECESSARY TO CONNECT SUCH SINKS.
8. PROVIDE A SHUT-OFF VALVE AT HOT AND/OR COLD WATER SERVICE TO EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTION(S).
9. PROVIDE A BACKFLOW PREVENTER AT EACH PIECE OF EQUIPMENT REQUIRING WATER CONNECTIONS. ( NOT INCLUDING SINKS )
10. APPLIANCES WITH CASTERS: MOVEMENT OF APPLIANCES SHALL BE LIMITED BY A RESTRAINING DEVICE INSTALLED IN ACCORDANCE WITH THE CONNECTOR AND APPLIANCE MANUFACTURER'S INSTALLATION
INSTRUCTIONS PER CMC SECTION 303.5.
A2.0
REMOVE ARCH
CONSTRUCTION
INSTALL NEW CROWN MOLDING IN
HATCHED AREA, PAINT TO MATCH
EXISTING
"CHARLEY'S PHILLY STEAKS"
LOGO. G.C. SHALL SUBMIT
G1
SHOP DRAWINGS TO L.L.
FOR APPROVAL.
3
A3.0
"CHARLEY'S
PHILLY STEAKS"
SIGN. G.C. SHALL
SUBMIT SHOP
DRAWINGS
G1
TO L.L. FOR
APPROVAL.
3'-6"
P-3
6
A3.1
11'-0' A.F.F. GYP.
BD. CLG. PAINT
P-1
FACE AND SIDE
T-2
9'-0" A.F.F. BOT.
OF LL. BULKHEAD
6"
6"
MENU
BEYOND
T-2
FACE AND
SIDE
8"
1
A4.0
2
A4.0
7'-0" A.F.F.
BOT. OF EXH.
HOOD
MT-1
SNEEZE GUARD
1
A4.0
5
A4.0
4
A4.0
3
A4.0
98
1
e
sinc
3'-10" A.F.F.
TOP OF TILE
S-1
S-1
6"
T-2
7'-0" A.F.F.
BOT. OF GYP.
BD. CURTAIN
WALL
4'-10" A.F.F.
TOP OF
SNEEZE GUARD
4'-4" A.F.F.
TOP OF SNEEZE
GUARD
2'-10" A.F.F.
TOP OF COUNTER
MT-2
SEE GATE DETAILS,
2/A1.0
S-1
T-2
1'-0"
6
T-1
8
A4.0
QTB-1
LEASE LINE
1'-0"
1
A3.0
SCALE: 1/2" = 1'-0"
RECESSED MENU BOARDS. G.C.
TO SUBMIT SHOP DWGS. TO L.L.
FOR APPROVAL PRIOR TO FABRIC.
11'-0' A.F.F.
GYP. BD. CLG.
PAINT
LEASE LINE
T-2
NEW 3-5/8"
MTL. STUD
WALL W/5/8"
GYP. BD. EA.
SIDE. FINISH
PER
ELEVATIONS.
T-1
SECTION
STOREFRONT ELEVATION
6
A3.1
MT-2
1'-0"
WC-1
1
A-4
EXISTING
L.L. NEUTRAL
PIER WITH
FINISHES TO
REMAIN.
1'-0"
P-1
2'-10" A.F.F.
TOP OF COUNTER
P-3
LEASE LINE
8'-6' A.F.F.
GYP. BD.
CLG. PAINT
Y
L
L
I
PH EAKS
ST
WC-1
S-1
3
A4.0
H
S
E
R
F
MADE
MENU BEYOND
EXH. HOOD
11"
PAINT STEEL
COL.
P-1
9'-0" A.F.F. BOT.
OF LL. BULKHEAD
3
A3.0
SCALE: 1/2" = 1'-0"
6
A3.1
T-2
"CHARLEY'S
PHILLY STEAKS"
LOGO. G.C. SHALL
SUBMIT SHOP
DRAWINGS TO L.L.
FOR APPROVAL.
RECESSED MENU BOARDS. G.C.
TO SUBMIT SHOP DWGS. TO L.L.
FOR APPROVAL PRIOR TO FABRIC.
T-2
P-1
11'-0' A.F.F. GYP.
BD. CLG. PAINT
T-2
48''
30''
8'-6' A.F.F.
GYP. BD. CLG.
PAINT
96''
P-1
48''
9'-0" A.F.F. BOT.
OF LL. BULKHEAD
P-1
MG1
G11
EXH. HOOD
EXH. HOOD
7'-0" A.F.F.
BOT. OF GYP.
BD. CURTAIN
WALL
P-1
IED
TIF
CER
WC-1
3'-10" A.F.F.
TOP OF TILE
7'-0" A.F.F.
BOT. OF GYP. BD.
CURTAIN WALL/
EXH. HOOD
%
100
MT-1
DA
US ICE
O
CHSTEAK
WC-1
8'-6' A.F.F.
GYP. BD.
CLG. PAINT
8"
P-1
P-1
NEW 3-5/8"
MTL. STUD
WALL W/5/8"
GYP. BD. EA.
SIDE. FINISH
PER
ELEVATIONS.
#
RECESSED LIGHT
FIXTURE
CHEESE
IN THE
WORLD
STOREFRONT ELEVATION
SCALE: 1/2" = 1'-0"
T-1
8
A4.0
QTB-1
4'-10" A.F.F.
TOP OF SNEEZE
GUARD
5
A-4
STOREFRONT
ELEVATIONS
LCD ORDER
MONITOR
QTB-1
2
A3.0
7'-0" A.F.F.
BOT. OF
EXH. HOOD
2'-10" A.F.F.
TOP OF COUNTER
T-1
QTB-1
1'-0"
T-1
T-1
T-1
MT-1
WC-1
3'-10" A.F.F.
TOP OF TILE
2'-10" A.F.F.
TOP OF
COUNTER
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
3-5/8" MTL.
STUDS CURTAIN
WALL, (3)
SIDES OF
HOOD.
STEAK
N. AMERICA . S. AMERICA . ASIA . AFRICA . EUROPE
WC-1
T-1
G1
6"
G1
8"
G2
1455 FRANKLIN MILLS CIR,
16'-0"
PHILADELPHIA, PA 19154
P-3
T-2
SPACE 852A ~ 818 SQ. FT.
P-3
4
A4.0
PHILADELPHIA MILLS
"CHARLEY'S PHILLY STEAKS"
SIGN. G.C. SHALL SUBMIT
G1
SHOP DRAWINGS TO L.L.
FOR APPROVAL.
SECTION
SCALE: 1/2" = 1'-0"
LEASE LINE
4
A3.0
A3.0
8'-6' A.F.F. GYP.
BD. CLG. PAINT
7'-0" A.F.F.
BOT. OF GYP. BD.
CURTAIN WALL/
EXH. HOOD
P-1
MALL COMMON AREA
MALL COMMON AREA
SNEEZE GUARD
SNEEZE GUARD
2'-10" A.F.F.
TOP OF COUNTER
QTB-1
FRP
MT-1
STOREFRONT ELEVATION
SCALE: 1/2" = 1'-0"
QTB-1
FRP
FRP
1
A3.1
REMOVABLE 2'x2' METAL
AIR GRILL, PAINT P-1.
2-1/2" GA.
STRAP.
FRP
WATER
HEATER
SPACE 852A ~ 818 SQ. FT.
LCD ORDER
MONITOR
PHILADELPHIA MILLS
4'-10" A.F.F.
TOP OF
SNEEZE GUARD
4'-4" A.F.F.
TOP OF SNEEZE
GUARD
PHILADELPHIA, PA 19154
P-1
EXH. HOOD
1455 FRANKLIN MILLS CIR,
P-1
P-1
REMOVABLE
CEILING PANELS
FRP
SHELVING
SHELVING
SHELVING
SHELVING
FRP
1-COMP
SINK
VG1
VG1
WALK-IN
FREEZER
WALK-IN
COOLER
10'-0"
10'-0"
FRP
SHELVING
ELECTRICAL PANELS
QTB-1
QTB-1
STOREFRONT ELEVATION
STOREFRONT ELEVATION
2
A3.1
SCALE: 1/2" = 1'-0"
QTB-1
SCALE: 1/2" = 1'-0"
SEE SHEET A-1 FOR
BLOCKING DETAILS
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
3
A3.1
2-1/2" GA.
STRAP.
SEE SHEET A-1 FOR
BLOCKING DETAILS
FRP
5/8" GYP BD.
OVER 6", 22 GA. MTL
STUDS AT 24" O.C.
FRP
SHELVING
SHELVING
SHELVING
SHELVING
FRP
SHELVING
SHELVING
WATER
HEATER
3/4" MTL TRIM
ANGLE. TRIM
COLOR TO MATCH
MENU BD. COLOR
AND FINISH
1 COMP. SINK
ICE
MACHINE
QTB-1
STOREFRONT ELEVATION
HAND
SINK
QTB-1
4
A3.1
2'-10"
3 COMP.
SINK
SAFE
3'-0"
4'-0"
3 COMP. SINK
WORK TABLE
SCALE: 1/2" = 1'-0"
10'-0"
10'-0"
SG2
CO2
5/8" GYP BD. OVER
2-1/2, 22 GA. MTL
STUDS AT 24" O.C..
LAP TO 6" STUDS
ABOVE.
FRP
SHELVING
MANAGER'S
DESK
LAP STUDS 36"
MIN.
T-2
SEE SHEET A-1 FOR
BLOCKING DETAILS
MOP SINK
RECESSED MENU
BOARD. VERIFY
RECESS DEPTH
WITH
MANUFACTURER
SHIM AS NEC. TO
ACHIEVE FLUSH
CONDITION AT
FACE OF MENU BD.
AND SOFFIT
STAINLESS STEEL
TRIM CAP AT
BOTTOM OF
SOFFIT/MENU BD.
CONTINUOUS 18 GA.
MTL CLIP ANGLE
4"
QTB-1
STOREFRONT ELEVATION
SCALE: 1/2" = 1'-0"
KITCHEN
ELEVATIONS
2"
QTB-1
5
A3.1
MENU SECTION
SCALE: 1-1/2" = 1'-0"
6
A3.1
A3.1
3'-10"
1'-2 1/2"
3'-10"
1'-2 1/2"
S-1
S-1
BULLNOSE EDGE, TYP.
9 1/2"
8"
SODA DISPENSER
SEE EQUIPMENT
PLAN
S-1
3'-10"
LEASE LINE
2"
1'-2 1/2"
8"
BULLNOSE EDGE,
TYP.
BULLNOSE EDGE, TYP.
1"
2"
2"
1"
S-1
6"
S-1
S-1
ADJUSTABLE S/S LEGS
ADJUSTABLE S/S LEGS
A4.0
MT-2
3 5/8" X 20 GA. RUNNER TRACK RAMSET AT
24" O.C. "HILTI" BRAND MODEL X-DNI
ICC-ES REPORT #1663
Scale: 1-1/2" = 1'-0"
QTB-1
QTB-1
PATCH MALL TILE AS REQ'D
PATCH MALL TILE AS REQUIRED
2
COUNTER SECTION
A4.0
3
3
3 5/8" X 20 GA. RUNNER TRACK RAMSET
AT 24" O.C. "HILTI" BRAND MODEL
X-DNI ICC-ES REPORT #1663
Scale: 1-1/2" = 1'-0"
3
4
COUNTER SECTION
A4.0
Scale: 1-1/2" = 1'-0"
SNEEZE GUARD. SEE SNEEZE GUARD DETAIL 7/A4.0
2
1
SEE SNEEZE GUARD
DETAIL 7/A4.0
R
IE
LP
11"
75°
11"
6"
2"
1/
"
10
3'-
M-100A CENTER
M-112A CENTER
4
M-100A LEFT AND RIGHT
CLEAR SILICONE
SEALANT
'-1
1"
MT-2
1/
2"
4
11
1/
S
2'-
NOTE:
PVC SLEEVES AT EACH SIDE FOR
INTER-CABINET CHASE, LOCATE CHASE
TOWARDS THE TOP OF THE CABINET, TYP.
8
3'-
1/
2"
℄
MT-2
4
COUNTER SECTION
A4.0
1/
5
COUNTER SECTION
A4.0
Scale: 1-1/2" = 1'-0"
4'-10"
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
PATCH MALL TILE AS REQUIRED
Scale: 1-1/2" = 1'-0"
3 5/8" X 20 GA. RUNNER TRACK RAMSET
AT 24" O.C. "HILTI" BRAND MODEL X-DNI
ICC-ES REPORT #1663
2'-0"
S-1
2"
2'-
10 1/2"
12'-7 1/2"
2'-7"
2"
7
1/
2"
8"
QTB-1
POWER SET FASTENERS, TYP.
8"
"
9
1/2" ALUMINUM
CHANNEL
'-8
10
ADJUSTABLE SHELF
PL-1
A4.0
Scale: 3/4" = 1'-0"
2'-10"
2'-7 1/2"
3'-10"
2'-4"
2"
PL-2
ON
DOORS
1'-2 1/2"
1'-6"
11"
11 1/2"
PL-1
STUDS
COUNTER SECTIONS
AND DETAILS
13'-5"
ADJUSTABLE S/S LEGS
1'-0"
15'-8"
6"
FRONT COUNTER PLAN
PL-1
1/
℄
0"
1'-
7
SEE SNEEZE GUARD
DETAIL 6/A4.0
2'-2"
GRILL STOP. SEE EQUIPMENT
PLAN & SCHEDULE.
11
5-1/4" X 7" CUT
OUT FOR NAPKIN
HOLDER
3/4 " FRT. PLYWOOD
OVER 3-5/8" 20 GA.
STEEL FRAMING
1
@ 16" O.C. MAX. A4.0
NEUTRAL PIER
1'-
2
1/
2"
2"
A4.0
1/
5-1/4" X 7" CUT
OUT FOR NAPKIN
HOLDER
(3) 4-1/4" Ø CUT OUT
TO FIT VOLRATH
MODEL #78710
2
5-1/4" Ø CUT OUT
FOR CUP DISP.
MODEL # ADJ-2
T-2
CLEAR SILICONE
SEALANT
QTB-1
2"
UD
ST
1
A4.0
3/4 " FRT. PLYWOOD
OVER 3-5/8" 20 GA.
STEEL FRAMING @
16" O.C.
1/2" ALUMINUM
CHANNEL
10
2'-
℄
UNDER COUNTER
LIGHTING. TYP.
T-2
3/4 " FRT.
PLYWOOD OVER
3-5/8" 20 GA.
STEEL FRAMING @
16" O.C.
6"
"
11
2
M-112A LEFT AND RIGHT
3
ACRYLIC LENS
COVER.
2'-10"
5
2'-
0"
3'-
1
3/4 " FRT.
PLYWOOD OVER
3-5/8" 20 GA.
STEEL FRAMING @
16" O.C.
LED LIGHT FIXTURE
1'-8"
0"
LEASE LINE
5-1/4" Ø CUT OUT
FOR CUP DISP.
MODEL # ADJ-2
SODA MACHINE
3/4 " PLYWOOD
OVER 2X4 FIRE
RETARDANT WOOD
STUDS @ 16" O.C.
BULLNOSE EDGE, TYP.
6"
2'-
UNDER COUNTER
FLUORESCENT T-8
LIGHTING COLOR
‘DAYLIGHT’
ACRYLIC LENS
COVER.
SNEEZE GUARD SUPPORT PART NUMBERS
GRILL STOP.
SEE EQUIPMENT
PLAN &
SCHEDULE.
S-1
STUDS
2"
1/
11
"
0
1'-
CONTRACTOR SHALL SUPPLY
AND INSTALL SNEEZE GUARD
FRP
TYPICAL
MT-1
BEHIND GRILL & FRYER
4'-4"
A4.0
Scale: 3/4" = 1'-0"
S-1
2'-10"
6
BULLNOSE EDGE, TYP.
FRP
TYPICAL
NOTE:
1. ALL FACE GLASS TO BE 1/4" TEMPERED
2. ALL SHELF GLASS TO BE 3/8" TEMPERED
3. NO FROSTED GLASS OR LOGOS
4. FINISH TO BE BRUSHED STAINLESS STEEL
5. LIGHT FIXTURE REQUIRED FOR 48" SHELF SECTION ONLY.
6. TO ORDER CONTACT: Andrew Nelson
Senior Estimator English Mfg., Inc.
916-638-9902 ext. 108
℄
0"
3'-
SNEEZE GUARD DETAIL
S-1
6"
BULLNOSE
EDGE, TYP.
STUDS
1'-
42" H. WALL
6"
S-1
4'-2"
8"
3'-1"
1'-8"
3'-1"
2"
2"
UT
RA
NE
2'-9 1/2"
13'-5"
3
A4.0
1'-2 1/2"
°
1/
7
2'-
"
2"
GLASS
6"
BULLNOSE EDGE, TYP.
2
1/
GLASS
MATRIX
SERIES FLUORESCENT
LIGHT FIXTURE KIT
SUPPLIED BY ENGLISH
MANUFACTURING
0"
3'10
3'-
4'-0 1/2"
75
GLASS
2'-11 1/2"
12" O.A.
GLASS
2"
2'-11 1/2"
1'-0"
1'-2 1/2"
2'-8"
3 5/8" X 20 GA. RUNNER TRACK
RAMSET AT 24" O.C. "HILTI" BRAND
MODEL X-DNI ICC-ES REPORT #1663
1'-6"
COUNTER SECTION
1
6"
PATCH MALL TILE AS REQUIRED
PHILADELPHIA, PA 19154
1/2" ALUMINUM
CHANNEL
QTB-1
1455 FRANKLIN MILLS CIR,
PL-1
SPACE 852A ~ 818 SQ. FT.
2'-10"
℄
3/4 " FRT.
PLYWOOD OVER
3-5/8" 20 GA.
STEEL FRAMING
@ 16" O.C.
PHILADELPHIA MILLS
6"
ADJUSTABLE S/S LEGS
STUDS
2'-7"
2'-10"
3/4 " FRT. PLYWOOD
OVER 3-5/8" 20 GA.
STEEL FRAMING @
16" O.C.
T-2
MT-2
1'-8"
℄
ACRYLIC LENS COVER.
1/2" ALUMINUM
CHANNEL
PL-1
PL-1
UNDER COUNTER
FLUORESCENT T-8
LIGHTING COLOR
‘DAYLIGHT’
STUDS
2'-10"
3/4 " FRT. PLYWOOD
OVER 3-5/8" 20 GA.
STEEL FRAMING @
16" O.C.
PL-1
S-1
ADJUSTABLE SHELF
BULLNOSE EDGE, TYP.
2'-7"
2'-7"
ACRYLIC LENS COVER.
T-2
S-1
PL-1
1'-8"
℄
UNDER COUNTER
FLUORESCENT T-8
LIGHTING COLOR
‘DAYLIGHT’
STUDS
PL-1
1"
BULLNOSE EDGE, TYP.
PL-1
8"
ADJUSTABLE SHELF
1'-0"
QTB-1
3/4 " FRT. PLYWOOD OVER
3-5/8" 20 GA. STEEL
FRAMING @ 16" O.C. MAX.
5
A4.0
UNDER COUNTER
LIGHTING. TYP.
4
A4.0
3
A4.0
8
A4.0
A4.0
SECTION @ BACK COUNTER
Scale: 1-1/2" = 1'-0"
OF.4
SCOPE OF WORK
BARRICADE:
A. CONTRACTOR WILL SUPPLY, INSTALL AND REMOVE ALL BARRICADES AS REQUIRED.
DEMOLITION:
A. SUPPLY ALL LABOR, MATERIALS AND EQUIPMENT FOR DEMOLITION IN ACCORDANCE WITH THE
CONTRACT DOCUMENTS.
B. REMOVE AND DISPOSE OF ALL DEBRIS AND GARBAGE AWAY FROM THE SITE.
PLUMBING & GAS:
A. SUPPLY AND INSTALL ALL PLUMBING AND GAS, INCLUDING METER PLACEMENT IF APPLICABLE, AS
REQUIRED PER FINAL APPROVED DRAWINGS INCLUDING ALL MATERIALS AND EQUIPMENT.
ELECTRICAL:
A. SUPPLY AND INSTALL ALL ELECTRICAL, INCLUDING METER IF APPLICABLE, AS REQUIRED PER FINAL
APPROVED DRAWINGS INCLUDING ALL MATERIALS AND EQUIPMENT.
HVAC:
A. SUPPLY AND INSTALL ALL HVAC AS REQUIRED PER FINAL APPROVED DRAWINGS INCLUDING ALL
MATERIALS AND EQUIPMENT.
HOOD, EXHAUST SYSTEMS, ANSUL FIRE SYSTEMS AND MAKE-UP AIR:
A. SUPPLY AND INSTALL ALL DUCTWORK AND RELATED WORK (i.e. DUCT SHAFT, FIRE WRAP) TO INSTALL
THE EXHAUST SYSTEMS AND MUA SYSTEMS AS PER CONTRACT DOCUMENTS AND LOCAL AUTHORITIES.
B. INSTALL EXHAUST HOODS, FANS AND MAKE-UP AIR UNIT AS SUPPLIED BY THE OWNER.
C. COORDINATE ANSUL SYSTEM INSTALLATION WITH THE OWNER'S APPOINTED CONTRACTOR.
D. SCHEDULE AND ATTEND ALL HOOD AND ANSUL INSPECTIONS.
E. CONTRACTOR SHALL ENAGE A QUALIFIED INDEPENDENT TESTING COMPANY TO PERFORM SMOKE
TEST OF ALL DUCTWORK, AND TO PERFORM AIR TESTING AND BALANCING OF THE AIR SYSTEM,
INCLUDING EXHAUST MAKE-UP AIR AND AIR CONDITIONING SYSTEMS. CONTRACTOR SHALL PROVIDE
SEPARATELY A CERTIFIED REPORT OF THE SMOKE TEST, AND A CERTIFIED REPORT OF THE AIR
TESTING AND BALANCING REPORT. THE REPORTS MUST BE CERTIFIED BY A QUALIFIED INDEPENDENT
PROFESSIONAL. THE CONTRACTOR SHALL SUBMIT THE TESTING REPORTS TO THE OWNER WITHIN THREE
DAYS AFTER THE TESTING. THE REPORT MUST BE RECEIVED BY THE OWNER PRIOR TO DISBURSEMENT
OF ANY HOLDBACK AMOUNT.
1455 FRANKLIN MILLS CIR,
PERMITS:
A. CONTRACTOR WILL BE RESPONSIBLE FOR PICK-UP OF BUILDING PERMITS.
B. CONTRACTOR WILL BE RESPONSIBLE FOR ELECTRICAL, PLUMBING, SPRINKLER AND ALL OTHER
PERMITS REQUIRED BY ALL SUB TRADES.
C. CONTRACTOR TO ATTEND AND SCHEDULE ALL INSPECTIONS AND TO ENSURE ALL WORK MEETS WITH
ALL LOCAL AND ANY OTHER APPLICABLE CODES AND REGULATIONS.
D. CONTRACTOR TO OBTAIN ALL FINAL INSPECTIONS APPROVALS AND OBTAIN THE CERTIFICATE OF
OCCUPANCY.
PHILADELPHIA, PA 19154
GENERAL:
A. CONTRACTOR SHALL INCLUDE IN HIS COST ALL HIS EQUIPMENT AND MATERIALS INCLUDING
HANDLING SHIPPING AND RECEIVING. CONTRACTOR WILL TAKE FULL RESPONSIBILITY FOR ALL ITEMS.
B. CONTRACTOR SHALL INCLUDE IN HIS COST ALL HANDLING AND RECEIVING OF OWNER'S EQUIPMENT
AND MATERIALS.
C. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE SECURE STORAGE AS REQUIRED FOR OWNER'S
EQUIPMENT AND INCLUDE COSTS IN HIS WORK.
D. REMOVE ALL DEBRIS MATERIALS AND EQUIPMENT FOR FINAL CLEAN UP OF THE ENTIRE STORE.
E. CONSTRUCT AS PER FINAL APPROVED STAMPED "CONSTRUCTION" DRAWINGS AND STAMPED "PERMIT"
SET OF DRAWINGS.
F. IT IS CONTRACTOR'S RESPONSIBILITY TO VERIFY THE CORRECTNESS OF THE DRAWING BEFORE
STARTING CONSTRUCTION, AND TO NOTIFY THE OWNER IN WRITING IF THERE ARE ANY ISSUES OR
ERRORS WITHIN 3 DAYS.
SPACE 852A ~ 818 SQ. FT.
ARCHITECTURAL SPECIFICATIONS
PHILADELPHIA MILLS
GENERAL NOTES
SPRINKLERS:
A. SUPPLY AND INSTALL SPRINKLERS IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
B. WHERE APPLICABLE, EXISTING SPRINKLER PIPING SHALL BE ADJUSTED TO SUIT NEW HEAD
LOCATIONS. ALL EXISTING PIPING THAT DOES NOT MEET CODE REQUIREMENTS SHALL BE REMOVED
AND REPLACED, AS REQUIRED.
C. THE SYSTEM INSTALLATION IS TO BE CARRIED OUT BY A QUALIFIED SPRINKLER COMPANY
APPROVED BY LANDLORD.
D. APPLY FOR, OBTAIN AND PAY FOR ALL PERMITS, LICENSES, WORKING DOCUMENTS REVIEWS,
INSPECTIONS AND EXAMINATIONS.
E. THE CONTRACTOR SHALL COORDINATE INSTALLATION WITH ALL TRADES AT SITE.
F. THE CONTRACTOR SHALL COORDINATE WITH THE MALL ADMINISTRATION FOR DRAIN TIME AND REFILL
OF SPRINKLER SYSTEM AND PAY FOR ANY FEES AS REQUIRED.
FLOORING:
A. TO SUPPLY AND INSTALL FLOORING SYSTEM AS PER FINAL APPROVED DRAWINGS INCLUDING ALL
MATERIALS AND EQUIPMENT.
B. TO SUPPLY AND INSTALL NEW FLOOR MEMBRANE AS PER FINAL APPROVED DRAWINGS.
FINISHES:
A. TO SUPPLY AND INSTALL ALL SURFACES FINISHES AS PER FINAL APPROVED DRAWINGS.
B. TO SUPPLY AND INSTALL ALL DOORS AS PER FINAL APPROVED DRAWINGS.
EQUIPMENT AND FIXTURES AND GRAPHICS:
A. INSTALL AND CONNECT ALL EQUIPMENT, FIXTURES AND GRAPHICS SUPPLIED BY OWNER AS PER
FINAL APPROVED DRAWING.
SIGNS:
A. CONTRACTOR TO COORDINATE SIGN INSTALLATION WITH OWNER APPROVED SIGN CONTRACTOR.
B. CONTRACTOR WILL ENSURE ALL ELECTRICAL WORK TO BE AVAILABLE FOR THIS INSTALLATION.
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
ARCHITECTURE
SPECIFICATIONS
AS1.0
OF-1
Z
2'X4' FLUORESCENT NIGHT LT (N/L)
2.
3.
P14
GFI
TIME CLOCK
T/C
9
Z
A-20
Z
CEILING MOUNTED LT FIXTURE.
4.
K12-1
PANEL "A"
GFI
SF-1 ON
ROOF
HD
TELEPHONE
BOARD
8
Z
Z
Z
Z
Z
MANUAL PULL STATION - 270-SPO
42" A.F.F.
F
HORN/STROBE-792-7A-006 80" A.F.F.
R
FAN SHUT DOWN RELAY W/
ENCLOSURE-MR-199X-13/C
S
DUCT SMOKE DETECTOR 6264B-001/
6260A-100/6261-003-6251B-001A
RT
REMOTE INDICATOR/TEST STATION 6262A-001
Z
TIE TO
15 A-11
VIA T/C
Z
15
5
S
Z
G
Z
Z
Z
G
Z
G
J
Z
G
Z
G
SIGN
6
3
Z
G
G
E
D
Z
Z
J
D
G
G
G
TIE TO
A-11
COORDINATE WITH THE TENANT AND PROVIDE NEW UNDER COUNTER COVE LIGHTS
TYPE "C" AS REQUIRED. MAKE ALL CONNECTIONS AS REQUIRED.
7
PROVIDE A MINIMUM 1/2" CONDUIT W/WIRE FROM TELEPHONE OUTLET BACK TO
TELEPHONE BOARD LOCATED IN WORK AREA. THIS IS TYPICAL FOR ALL TELEPHONE
OUTLETS.
8.
FURNISH A TYPE WRITTEN CIRCUIT DIRECTORY CARD FOR ALL PANELS,
LISTING ALL USED AND SPARE CIRCUITS.
8
9.
CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL
REQUIREMENTS AND LOCATIONS OF ALL HVAC EQUIPMENT PRIOR TO
INSTALLATION.
CONTRACTOR SHALL COORDINATE WITH LANDLORD AND INSTALL NEW TELEPHONE
BOARD AS REQUIRED. EXTEND EXISTING TELEPHONE CONDUIT AND CABLE TO
TENANT'S TEL. BD "TTB". COORDINATE ALL TELEPHONE REQUIREMENTS WITH TENANT.
CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND DATA/TEL.
OUTLETS. THE TELEPHONE SYSTEM SHALL BE COMPLETE AND FUNCTIONAL.
9
ALL OUTLETS WITHIN 6' OF ANY SINK SHALL BE GFI OUTLETS. ALL KITCHEN AREA
OUTLETS SHALL BE WITH GFI TO COMPLY WITH N.E.C. STD. #210.8(B)(2). TO
ECONOMIZE THE COST THE CONTRACTOR SHALL INSTALL FIRST OUTLET AT WHICH THE
HOME RUN IS CONNECTED, WITH GFI AND ALL OTHER DOWN STREAM OUTLET NORMAL
WITHOUT GFI.
10
THE CONTRACTOR SHALL COORDINATE WITH LANDLORD AND DETERMINE WHAT KIND
OF LIFE SAFETY AND FIRE ALARM DEVICES ARE REQUIRED BEFORE BIDDING FOR THE
PROJECT. USE EXISTING OR FURNISH AND INSTALL NEW FA DEVICES AS REQUIRED, IN
COMPLIANCE WITH THE POWER PLAN AND ANSUL WIRING DIAGRAM, LANDLORD'S
CRITERIA, NFPA AND LATEST APPLICABLE CODE REQUIREMENTS. TIE TENANT'S FA
SYSTEM TO THE BASE BUILDING FA SYSTEM AS REQUIRED.
SMOKE DETECTOR - 6250B/6251B-001A
CONCEALED IN WALL, CEILING OR
UNDER CONDUIT RUN
CONSISTING OF:
- SMALL LINES INDICATE POWER
NON GROUNDED CONDUCTORS.
G
THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND INSTALL ALL CABLES AND
CONNECTIONS, AS REQUIRED, OF ALL COMPONENTS THAT ARE PART OF THE WALK-IN
COOLER AND WALK-IN FREEZER TO BE FULLY FUNCTIONAL.
A-7
VIA T/C
15 PROVIDE SHUNT TRIP CIRCUIT BREAKER TO ALL EQUIPMENT UNDER THE HOOD.
19. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310-16,
2008. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES
SHALL BE USED IN PLACE OF #12 FOR CIRCUITS LONGER THAN 100 FEET FROM
PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE
INSULATION SHALL BE THHN OR THWN.
16 FURNISH AND INSTALL POWER CIRCUITS FOR TOASTER, INSTALL 30A, 208V, 1P, TWIST
AND DETERMINE EXACT RATING OF ALL EQUIPMENT AND TYPE OF REQUIRED POWER
LEAD CONNECTIONS AT EACH EQUIP. MUST ADJUST SIZE OF BREAKERS IF OR AS
REQUIRED. THIS IS TYPICAL.
18 DETERMINE EXACT LOCATION OF HOOD AND ANSUL PANELS AT SITE WITH HOOD
PACKAGE. CONTRACTOR SHALL ROUTE POWER CIRCUIT FOR EXHAUST AND SUPPLY
FANS FROM POWER PANEL TO THE HOOD PANEL AND FROM HOOD PANEL TO THE
EXHAUST AND SUPPLY FANS. COORDINATE WITH HOOD MFG. DRAWING FOR
ADDITIONAL INFORMATION. THE CONTRACTOR SHALL FURNISH AND INSTALL 460V, 3
POLE, FUSED NEMA 3R, DISC. SWITCHS FOR EXHAUST AND SUPPLY FANS. INSTALL A
WEATHER PROOF GFI OUTLET NEAR THE FANS ON THE ROOF. MAKE ALL CONNECTIONS
AS REQUIRED.
20
27. CONDUCTORS SHALL BE COPPER PER LL CRITERIA.
28. ALL BREAKERS USED FOR LIGHTING CIRCUITS SHALL BE CONTINUOUS DUTY
LIGHT SWITCHING RATING.
S
ORDER ANNOUNCEMENT
AMPLIFIER, LOCATED
UNDER SALES COUNTER AMP
ON SHELF EQUIPMENT
ITEM E5.
REMOTE CEILING RECESSED
ORDER ANNOUNCEMENT
SPEAKER EQUIPMENT ITEM E6.
M ORDER ANNOUNCEMENT
GOOSENECK MICROPHONE (18"
FLEX) SALES COUNTER TOP
MOUNTED EQUIPMENT ITEM E2.
SYMBOL LEGEND
SALES COUNTER SHELF
ORDER ANNOUNCEMENT
MICROPHONE EQUIPMENT ITEM E2.
M
OFFICE FAX
OFFICE TELEPHONE
OFFICE COMPUTER INTRANET
AMP
S
NOTES:
1. G.C. IS RESPONSIBLE TO PULL THE CORRECT WIRE TO BRING THE PHONE
LINE FROM THE DENMARK.
2. INSTALL THE APPROPRIATE JACK TO SUPPORT THE PHONE AND DSL ROUTER.
17 CONTRACTOR SHALL COORDINATE WITH KITCHEN AND REFRIGERATION CONTRACTORS
24. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED THERMAL MAGNETIC TYPE.
TWO (2) AND THREE (3) POLE MOLDED CASE CIRCUIT BREAKERS SHALL BE
WITH COMMON TRIP.
26. ROMAX, TYPE AC AND NM CABLES SHALL NOT BE PERMITTED.
EXISTING
TELEPHONE
SERVICE CONDUIT
TO SPACE BY
TTB
LANDLORD
TELEPHONE
EQUIP. BD.
OFFICE
LOCK OUTLET, DETERMINE EXACT LOCATION OF OUTLET AT SITE WITH TENANT. MAKE
ALL CONNECTIONS AS REQUIRED.
19 COORDINATE POWER REQUIREMENTS TO VAV-1 WITH SUPPLIER. INSTALL A GFI
SCALE: 1/4" = 1'-0"
CONDUIT TO TTB FROM
EACH TELEPHONE OUTLET
INTERLOCK SHUNT TRIP W/ ANSUL SYSTEM.
23. THE GROUND ON THE SEPARATELY DERIVED SERVICE SHALL BE BONDED TO
THE BUILDING STEEL AND TO THE INCOMING COLD WATER METAL PIPING WITH
CAD WELD CONNECTION. REFER TO KEY NOTE #22.
SCALE: 1/4" = 1'-0"
4"
COOLER AND FREEZER ARE SEALED ON THE INSIDE IN COMPLIANCE WITH N.E.C. ART.
300-7 "REQUIREMENT TO PREVENT CONDENSATE BUILD UP WITHIN THE CONDUIT".
18. ALL CONDUIT RUNS ABOVE CEILING SHALL BE PARALLEL OR PERPENDICULAR
TO THE COLUMN LINES.
ELECTRICAL LIGHTING PLAN
3 PHONE LINES
1. VOICE/FAX (OFFICE)
2. CREDIT CARD (NEXT TO CASH REGISTER)
3. DATA LINE FOR COMPUTER (OFFICE)
14 CONTRACTOR SHALL MAKE SURE THAT CONDUIT PENETRATIONS OF THE WALK IN
22. MC CABLES SHALL NOT BE USED FOR HOME RUN CIRCUITS AND FOR THE
WIRING WITHIN PARTITION OR DEMISING WALL CONSTRUCTION. ALL IN-WALL
CONCEALED WIRING MUST BE RUN IN RIGID CONDUITS.
- BIG LINE INDICATES
NEUTRAL CONDUCTOR
UNDER COUNTER LIGHT
TYPE "C" (16'-10")
13
21. CONTRACTOR MAY USE FLEXIBLE CONDUIT FROM JUNCTION BOX TO THE
LIGHTING FIXTURE, BETWEEN LIGHTING FIXTURES, AND TO OTHER DEVICES
PROVIDED THE LENGTH OF THE FLEX. CONDUIT IS NOT MORE THAN 6 FEET.
Z - GROUND CONDUCTOR
E
16. CONTRACTOR, UPON COMPLETION OF HIS WORK , SHALL BE RESPONSIBLE TO
PROVIDE ANY AND ALL CERTIFICATIONS.
20. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL. STEEL OR EMT
COND. AND IN COMPLIANCE WITH THE N.E.C. AND LAND LORD'S DESIGN
CRITERIA.
REFER TO THE CODED NOTE NUMBER.
Z
THE CONTRACTOR SHALL COORDINATE WITH THE KITCHEN APPLIANCES CONTRACTOR
AND PROVIDE ALL HARDWARE AND CONNECTIONS AS REQUIRED. THIS IS TYPICAL.
ELECTRICAL POWER PLAN
3
FOR THE VAV UNIT. TIE RELAY INTO DUCT MT'D SMOKE DETECTOR WHICH WHEN
ACTIVATED WILL FULLY OPEN VAV UNIT, SHUT DOWN HOOD SUPPLY FAN AND SIGNAL
LANDLORD'S MASTER FIRE ALARM CONT. PANEL, IF REQ'D. PROVIDE CONDUIT, WIRES
AND MAKE ALL CONNECTIONS AS REQUIRED. DETERMINE BEST LOCATION OF REMOTE
INDICATOR AT SITE.
12
25. UNLESS NOTED OTHERWISE, WIRE AND CABLE SIZES SHALL BE IN COMPLIANCE
WITH KEY NOTE # 22, RISER DIAGRAM AND THE N.E.C. TABLE 310-16.
EXTEND THE
CONDUIT TO
TTB IN OFFICE
BY TENANT'S
CONTRACTOR.
11 FURNISH AND INSTALL NEW DUCT SMOKE DETECTOR, RELAY AND REMOTE INDICATOR
15. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER
AUTHORITIES. AND LANDLORD'S MANAGER.
17. CONTRACTOR SHALL COMPLY WITH THE LANDLORD'S DESIGN CRITERIA FOR
ELECTRICAL AND FIRE ALARM SYSTEMS. MAKE NECESSARY CONNECTIONS
BETWEEN TENANT'S FIRE DETECTING DEVICES AND THE LAND LORD'S FIRE
ALARM STATION.
HEAT DETECTOR -281B
Z
Z
F
TYP
G
Z
Z
D
4
D
Z
15
G
Z
A-34
15
S
J
G
Z
5
TIE TO
15 A-11
Z
Z
15
A-12
TIE TO
A-23
6
INTERIOR TELEPHONE WIRING SHALL INCLUDE FURNISHING AND INSTALLING
ALL TELEPHONE JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH
THE TENANT.
14. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO
INSURE THE FIRE RATING INTEGRITY OF THE INVOLVED AREAS.
SD
G
D
UNDER COUNTER LIGHT
TYPE "C" (16'-9")
6
INSTALL NEW SWITCH LEG AS SHOWN. EACH SWITCH DESIGNATION WHICH CONTROL
THE SPECIFIC LIGHT IS MARKED ON THE PLAN.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE
PROPERTY OWNER'S PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO
INSTALLATION.
WATER HEATER
H
S
5
Z
Z
Z
Z
A-30
E
E
E7
FOR HOOD
LIGHT
MENU BOARDS
GFI
GFI
Z
FOR SNEEZE
GUARD LIGHT
SIGN
Z
9
9
9
Z
A-31
GFI
GFI
GFI
9
S
TIE TO
A-7
VIA T/C
D
Z
IG
Z
E
E
K10
K1-1
J
Z
K9
E
D
Z
E6
E2
5
7
21
10
2
TYP
TIE TO
A-27
K4
E
Z
D
Z
FOR HOOD
LIGHT
15 A-11
Z
Z
K5
Z
3
Z
E
E
Z
20
H1
Z
Z
K3
A-16,18
Z
E
Z
9
E1
A-6
E5
E3
GFI GFI
S
HD
15
A-19
E
Z
GFI
A-22
K9
15
K11
A-20
E7
E4
K6
5
PULL STRINGS SHALL BE PROVIDED IN ALL EMPTY CONDUIT. FOR TELEPHONE
AND LOW VOLTAGE SYSTEM.
TWO WAY SWITCH
Z
A-2
20
A-25
9
SJ
Z
D
Z
9
IG
Z
P1-1
16 #10
5
Z
A-29
9
P1-2
20
E
Z
21
9
A-38
Z
9
GFI
ROUTE ALL LIGHTING/SIGN CIRCUITS THROUGH A WATT STOPPER 8 RELAY PEANUT
PANEL LP8S-8-G-115 AND PROVIDE AS-100-W SWITCHES FOR ALL LIGHTING SWITCHES.
(FOR LOCAL CONTROL AND TIME OF DAY OVERRIDE )
12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS
UNLESS NOTED OTHERWISE.
E
E
Z
H2
GFI
Z
9
GFI
GFI
GFI
D
E
Z
Z
GFI
Z
7
4
ELECTRICAL POWER PANEL
A
A
Z
GFI
GFI GFI
GFI
J
D
Z
Z
E5
E2
7
Z
Z
E12
5
WH
Z
18
GFI
E13
Z
Z
E1
GFI
Z
E3
9
Z
E4
E10
E
Z
9
9
E
E14
E15
S
TYP
EX
E
E11
K-14
1
Z
Z
4
Z
P2
9
D
S
Z
GFI
A-21 A-15
EF-2 ON
ROOF
18
TIE TO
A-8
(4) RECESSED
OUTLETS FOR LCD
MENU BOARDS
E
CONTRACTOR FURNISH AND INSTALL ALL NEW WIRING AS SHOWN ON THE
ELEC. PLANS AND RISER DIAGRAM. ALL NEW WIRING SHALL BE IN COMPLIANCE
WITH N.E.C. TABLE 310-16, AND PANEL SCHEDULES.
CONTRACTOR SHALL PROVIDE A NEW TIME CLOCK TC AS SHOWN ON THE LIGHT
CONTROL DIAGRAM ON SHEET E2. INSTALL JUNCTION BOXES AND SWITCHES FOR THE
MENU BOARD AND STORE SIGN CIRCUITS AS REQUIRED.
11. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED
IN ACCORDANCE WITH N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL
HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN.
A
Z
F
21
A-28
10
F
P8
HD
DISCONNECT SWITCH
SS
A-26
Z
H-14,16,18
THROUGH
HOOD PANEL
A-5
VIA T/C
Z
110 CD
10
JUNCTION BOX
1
3
10. ALL OUTLET AND SWITCHES COVER PLATES SHALL BE STAINLESS STEEL. ALL
OUTLET BOXES SHALL BE MOUNTED FLUSH IN WALLS AND SHALL BE MOUNTED
AT HEIGHT AS INDICATED ON THE EQUIP. PLAN. COORDINATE ALL LOCATIONS
WITH EQUIPMENT INSTALLATION AND ARCHITECTURAL DRAWINGS.
TELEPHONE JACK
Z
18
Z
A-3
Z
F
H-8,10,12
TIE TO THROUGH
A-8
HOOD PANEL
J
A-1
CONTRACTOR SHALL VERIFY AND USE EXISTING POWER SUPPLY AND
EQUIPMENT. HOWEVER PROVIDE NEW POWER PANELS, XFRMR AND FEEDERS
TO COMPLY WITH PANEL SCHEDULES. REFER TO KEY NOTE #22.
CONTRACTOR MUST COORDINATE AND SUBMIT CUT SHEETS OF ALL LIGHT FIXTURE
AND MUST GET APPROVAL FROM THE OWNER OF ALL LIGHT FIXTURE MODEL NUMBERS
BEFORE PURCHASING ANY NEW LIGHT FIXTURES.
Z
Z
A-35,37
K7
KITCHEN EQUIP. WITH AMPERE
RATING AS SHOWN AT PANEL
SCHEDULE AND AT DRAWING.
S
14
13
Z
Z
S
Z
GFI
Z
K8
N/L
EF-1 ON
ROOF
9
A-9
2
LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR
EMBOSSED PLASTIC NAME STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER
DIAGRAM.
SPECIAL "TWIST LOCK RECEPT" WTR
PROOF, 208V, 3Ø, OR 208V, 1Ø, FOR
13
11
TIE TO
A-8
Z
A
ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN
DOCUMENTS, LANDLORD DESIGN CRITERIA AND N.E.C. REQUIREMENTS.
PROVIDE LOCK TAB AT THESE CIRCUITS WHICH FEED POWER TO EXIT, NIGHT AND
EMERG. LIGHTS IN "ON" POSITION. NIGHT LIGHTS SHALL BE CONTROLLED BY A KEYED
SWITCH AND ALL EXIT AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ANY
LOCAL SWITCHES.
7.
HEIGHT 16" TO BOTTOM UNLESS
NOTED OTHERWISE. (TYP.)
14
Z
6.
DUPLEX RECEPTACLE WITH
120 V, 20 AMPERE RATING.
1
Z
RT R
EM
Z
19
EM
S
Z
Z
22
EMERGENCY LIGHT
TYP
A-40,42
VAV-1
ABOVE
CEILING
GFI
A-33
PANEL "H"
Z
Z
Z
2
1
H-7,9,11
THROUGH
HOOD PANEL
110 CD
H-1,3,5
5.
10
45 KVA XFRMR
ABOVE CEILING
WP
GFI
10
EXIT LIGHT
A
22
22
18
A
Z
A-23
3
1
PHILADELPHIA, PA 19154
CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY
NOTES, ELECTRICAL PLANS AND THE LANDLORD DESIGN CRITERIA BEFORE
BIDDING AND STARTING ANY CONSTRUCTION WORK.
Z
1.
1455 FRANKLIN MILLS CIR,
2'X4' FLUORESCENT
SPACE 852A ~ 818 SQ. FT.
A-8
H-13,15,17
KEY NOTES:
GENERAL NOTES:
PHILADELPHIA MILLS
SYMBOLS
OUTLET NEAR THE VAV IN THE CEILING AS REQUIRED. MAKE ALL CONNECTIONS AS
REQUIRED.
ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND
SEALED WITH WHITE SILICONE. THIS IS TYPICAL.
21 PROVIDE KEY-LOCK TABS AT THESE CIRCUITS. ROUTE CASH REGISTER CIRCUITS WITH
AN ISOLATED GROUND CONDUCTOR.
22 INSTALL NEW POWER SUPPLY (100 AMP, 277/480V, 3 PHASE, 4W) IN COMPLIANCE WITH
THE RISER DIAGRAM, THE PANEL SCHEDULES AND AS DESCRIBED BELOW:,
COORDINATE WITH LANDLORD AND INSTALL NEW DISC. SWITCH AND METER
AT LANDLORD`S METER CENTER. RUN NEW CONDUITS AND POWER FEEDERS
FROM LANDLORD`S METER CENTER TO TENANT'S SPACE.
FURNISH AND INSTALL NEW PANELS "H" & " A" IN COMPLIANCE WITH THE
RISER DIAGRAM AND PANEL SCHEDULES. ALL BREAKERS IN ALL PANELS
SHALL BE BOLTED TYPE. REFER TO FOOT NOTES AT PANEL SCHEDULES.
FURNISH AND INSTALL 45 KVA, 480V- 120/ 208V, 3 PHASE 4 WIRE SECONDARY
DRY TYPE TO REMAIN. VERIFY THE XFRMR IS WITH SIX STANDARD TAPS (2+2.% AND 4- -2.5%). . THE XFRMR NEUTRAL SHALL BE BONDED TO THE
BUILDING STEEL AND COLD WATER PIPE IN COMPLIANCE WITH N.E.C. 250
REQUIREMENTS.
THE GROUNDING SYSTEM SHALL BE INSTALLED IN COMPLIANCE WITH N.E.C.
STD #250 REQUIREMENTS. ALL EQUIPMENT SHALL BE GROUNDED IN
COMPLIANCE WITH N.E.C. STD. #250, 2008. AND UL REQUIREMENTS.
UNLESS NOTED OTHERWISE THE CONTRACTOR SHALL USE FOLLOWING SIZE OF
WIRES PER N.E.C. TABLE 310-16.
(1) USE # 12 AWG, COPPER, THWN OR THHN, FOR 20A BREAKERS.
(2) USE # 10 AWG, COPPER, THWN OR THHN, FOR 25A AND 30A BREAKERS.
ORDER ANNOUNCEMENT
AMPLIFIER EQUIPMENT ITEM E5.
(3) USE # 10 AWG, COPPER, THWN OR THHN, FOR EXH. FANS AND RTU UNIT
BREAKERS.
(4) USE # 8 AWG, COPPER, THWN OR THHN, FOR 35A AND 50A BREAKERS.
ORDER ANNOUNCEMENT CEILING
RECESSED SPEAKER EQUIPMENT ITEM E6.
(5) USE # 6 AWG, COPPER, THWN OR THHN, FOR 60A BREAKERS.
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
ORDER ANNOUNCEMENT DIAGRAM
NO SCALE
TELEPHONE DIAGRAM
NO SCALE
LIGHTING FIXTURE SCHEDULE
TYPE
SYMBOL
DESCRIPTION
2x4 RECESS TROFFER
A
LED LIGHTING STRIP
C
D
E
G
EX
QTY.
6
34'
MANUFAC.
LITHONIA
W.A.C.
LIGHTING
LAMP
CATALOG
2GTL4 347 LP835
LED-T24-5-WT (TAPE)
EN-24100-RB2-T &
LEDT-CL
LED (39W) 4000
LUMEN
12 LED / FT
3 WATTS / FT.
RECESSED CAN LIGHT
WALL WASH
12
LITHONIA
6G1MW LED
10.8 WATT LED
(620 LUMENS)
RECESSED DOWN LIGHT
20
LITHONIA
6G1MW LED
10.8 WATT LED
(620 LUMENS)
RECESSED DOWN LIGHT
14
JUNO
EXIT LIGHT
1
ATLITE
EMERGENCY LIGHT
1
SURELITE
IC1 LEDG4-3K- 1
14W-WH
PNLRU
CC-2
EM
MTG.
VOLT
RECESSED
120
UNDER
COUNTER
RECESSED
RECESSED
120
120
120
1
2
REMARKS
PROVIDE ALL REQ'D. HARDWARE
0-10V DIMMING
10%-100% DIMMING
3
4
LAMPS/
FIXT.
BALLASTS
ELECTRONIC
1
BALLAST/
FIXT.
TOTAL
WATT
1
39
FURNISHED
W/UNIT
UNIVERSAL
120
PROVIDE ALL REQ'D. HARDWARE
N/A
N/A
120
MR
MR
CAT5E
1
1
10.8
10%-100% DIMMING
1
1
10.8
90 MINUTE BATT. BACKUP POWER
POS STATIONS
(VERIFY NUMBER OF
POS STATIONS W/
OWNER)
102
10%-100% DIMMING
LINE VOLTAGE DIMMING
90 MINUTE BATT. BACKUP POWER
VGA
CAT5E
14
UNIVERSAL
LEGEND
VGA
14 WATT LED
FURNISHED
W/UNIT
LCD MONITORS
(VERIFY NUMBER OF
MONITORS W/
OWNER)
N/A
N/A
N/A
N/A
N/A
20
N/A
20
NOTES:
1
ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT FIXTURES.
3
ALL LAMPS IN FLUORESCENT LIGHT FIXTURES TO BE SYLVANIA UNLESS NOTED OTHERWISE.
2
INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND
ACCORDING TO CODE REQUIREMENTS.
4
PROVIDE LIGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD SERVICE AREA.
POS USB
CR
USB KEYPAD
"BUMP BAR"
(VERIFY NUMBER
OF BUMP BARS W/
OWNER)
CAT5E
CAT5E
COMP "DENMARK"
OFFICE
CP CPU
SERVER
PR
REG. PRINTER ON
SALES COUNTER
SHELF
POS USB
CR
PR
REG. PRINTER ON
SALES COUNTER
SHELF
P.O.S. DIAGRAM
NO SCALE
CR
REGISTER W/ CASH DRAWER EQUIPMENT ITEM E1
PR
REGISTER PRINTER EQUIPMENT ITEM E4
MR
REGISTER W/ VDU CONTROLLER EQUIPMENT ITEM E7
CP
COMPUTER, CPU, KEYBD, & MOUSE EQUIPMENT ITEM E13
MR
COMPUTER MONITOR EQUIPMENT ITEM E14
PR
COMPUTER PRINTER EQUIPMENT ITEM E1
P.O.S. SYSTEM NOTES:
(A)
PROVIDE 1-1/2" CONDUIT FOR ALL CABLING.
(B)
G.C. TO PROVIDE AND INSTALL A SEPARATE IG OUTLET
FOR EACH MONITOR. SEE PLAN FOR LOCATION.
(C)
G.C. TO PROVIDE AND INSTALL A SEPARATE IG OUTLET
FOR EACH POS STATION. SEE PLAN FOR LOCATION.
P.O.S. SPECIAL NOTES:
ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL ALL POS
SYSTEM RACEWAYS AND OUTLET BOXES, WIRING AND
TERMINATIONS FOR POS.
EQUIPMENT SHALL BE FURNISHED AND INSTALLED BY OWNER'S
DESIGNATED SUPPLIER/CONTRACTOR. CONTACT VENDORS BELOW
FOR COMPLETE INFORMATION ON WIRING REQUIREMENTS, POS
DATA LINES SHALL BE INSTALLED IN CONDUIT SEPARATE FROM ALL
POWER CONDUCTORS.
AUPHAN DINING AND NEW CREDIT CARD PROCESSOR CONTACT:
THINH PHAN (AUPHAN SOFTWARE)
DIRECT: 604.836.2095
TOLL FREE: 888.618.6688 X8000
OFFICE: 604.639.7049, 888.618.6688
FAX: 866.607.9645
CREDIT CARD APPLICATION WITH MERCURY SYSTEM (THIS SYSTEM
WILL COME WITH THE REGISTER)
CONTACT: PETE ZIEROLF
MERCURY PAYMENT SYSTEMS MERCHANT RELATIONS MANAGER
800.846.4472 x4825
DIRECT: 970.335.4825
FAX: 970.385.2730
ELECT. POWER &
LIGHTING PLANS
NOTES AND DETAILS
E1.0
MTD: RECESSED
DESCRIPTION OF LOAD
BRKR KVA PHASE LOAD CIR
PHASE
CIR KVA PHASE LOAD BRKR
DESCRIPTION OF LOAD
AMP P ØA
ØB
ØC NO A B
C NO ØA
ØB
ØC P AMP
20 3 3.00
1
2 14.57
3 70 45 KVA XFRMR - PANEL "A"
14.00
3
4
3.00
3.00 5
14.47
6
20 3 0.56
7
8 0.54
3 20 EF-1
0.56
9
10
0.54
0.54
0.56 11
12
13
14 0.24
30 3 4.00
3 20 EF-2
15
16
4.00
0.24
4.00 17
0.24
18
EQ. NO.
H VAV-1 WITH ELEC HEATER
M SF-1
P14
W WATER HEATER
SPACE
19
21
23
TOTAL
H
M
T
7.56 7.56
7.56
LEGEND
AIR CONDITION
MOTOR/FAN
TRANSFORMER/PANEL
W WATER HEATER
T (1)
ELECTRICALLY HELD
CONTACTOR (TYP.)
M
M
C
SPACE
20
22
24
MANUAL OVERRIDE
SWITCH "TR"
15.35 14.78 15.25 TOTAL
A-1
ØA
ØB
ØC
22.91 22.34 22.81 TOTAL CONNECTED KVA
TOTAL CONNECTED AMPS
81
83
83
A-3
A-5
T
(1) REFER TO PANEL "A" SCHEDULE FOR THIS LOAD DETAILS.
A-7
VOLTS
/
0
H.P.
CONN.
CASH REGISTER WITH EXTRA TILL
120
1
20
0.36
-
C/P
GOOSENECK MICROPHONE (13" FLEX)
120
-
-
0.10
-
-
MODEL
DESCRI P T I ON
AMP. KW.
E1
2
X
BY OWNER
BY OWNER
E2
2
X
-
-
E3
2
X
BY OWNER
BY OWNER
CASH REGISTER
120
-
-
0.10
-
-
E4
2
X
BY OWNER
BY OWNER
REGISTER PRINTER
120
-
-
0.36
-
-
E5
2
X
-
-
PASEO 20WATT AMPLIFIER
120
-
-
0.10
-
-
E6
1
X
-
-
CEILING MOUNT SPEAKER
120
-
-
0.10
-
-
E7
2
X
BY OWNER
BY OWNER
LCD ORDER MONITOR
120
-
-
0.36
-
-
E10
1
X
BY OWNER
BY OWNER
PHONE
120
-
-
-
-
-
E11
1
X
BY OWNER
BY OWNER
FAX
120
-
-
-
-
-
E12
1
X
BY OWNER
BY OWNER
TV/DVD COMBINATION UNIT
120
-
-
-
-
-
E13
1
X
BY OWNER
BY OWNER
COMPUTER (CPU) KEYBOARD, AND MOUSE
120
-
-
-
-
-
E14
1
X
BY OWNER
BY OWNER
COMPUTER MONITOR
120
-
-
-
-
-
E15
1
X
BY OWNER
BY OWNER
COMPUTER PRINTER & PRINTER CABLE
120
-
-
-
-
-
CUSTOM
TYPE 1 EXHAUST HOOD W/ SELF-CONTAINED M/U
AIR, ROOF CURB, AND ROOFTOP EXHAUST FAN.
120
-
0.1
-
-
-
H1
2
X
CAPTIVE AIR
H2
1
X
ANSUL
R-102
HOOD FIRE SUPPRESSION SYSTEM
120
-
0.1
-
-
-
K1-1
1
X
MIGIKITCH'N
MKG72
GAS GRILL, 180,000 BTU, LOW PROFILE, 72"
GRIDDLE PLATE W/ CORD & PLUG FOR CONTROLS
120
1
1.32
-
-
-
K3
1
X
PITCO
SEBNB14
DUMP STATION
120
1
6.9
0.85
-
-
K4
1
X
HATCO
K3 MOUNTED HEAT LAMP
120
1
6.9
0.85
-
-
K5
1
X
LINCOLN
IMPINGER 1301
CONVEYOR TOASTER
208
1
27.0
6.00
-
NEMA 6-50P
K6
1
X
SERVER
81290
HOT TOPPING
TO LIGHTING
A-11
SPARE
PANEL "A"
(2)(3)
K
K
R
K
R
(4)(1)
M
MTD: RECESSED
INTERIOR LIGHTING CONTROLS
BRKR KVA PHASE LOAD CIR
PHASE
CIR KVA PHASE LOAD
DESCRIPTION OF LOAD
EQ. NO.
AMP P ØA
ØB
ØC NO A B
C NO ØA
ØB
ØC
20 1 0.30
1
2 0.60
LIGHTS KITCHEN
0.40
SALES
3
4
1.00 5
MENU BOARDS
6
0.65
SIGN
1.00
7
8 1.50
0.50
0.40
WALK-IN CLR/FRZR K7,8
9
10
0.20
HOODS, U/C, S.G.
12
1.00 11
RESERVED FOR SHUNT TRIP
13
14
15
16
3.00
20 1
0.84
K14
FOOD PROCESSOR
SPACE
17
18
3.00
K6
HOT TOPPING
19
20 1.80
20 1 1.00
0.80
21
22
1.70
BAG`N`BOX
P2
1.00 23
ROOF OUTLET
24
SODA DISPENSER
1.85
25
26 1.50
P1-1,P1-2
0.36
SPEAKER, ORDER MONITORS E6, E7
27
28
1.00
0.60
1.02 29
30
CASH REG. / PRINT. / KV'S E1-1:E1-5
1.02
31
32
CASH REG. / PRINT. / KV'S E1-1:E1-5
1.00
VAV SERVICE OUTLET
1.00
33
34
K7
3.00 35
WALK-IN COOLER
30 2
36
37
38 1.00
3.00
SPACE
39
40
3.00
3.00
41
42
TOTAL
L
R
LEGEND
LIGHTING
RECEPTACLE
K
I
M
KITCHEN EQUIPMENT
MISCELLANEOUS
MOTOR/FAN
8.17 3.80 7.02
BRKR
DESCRIPTION OF LOAD
P AMP EQ. NO.
1 20 K9
REFRIG. SANDWITCH PREP. K (2)
RESERVED FOR SHUNT TRIP
LEMONADE DISPENSER
1 20 K11
K
CONVENIENCE OUTLETS
R
T.C. / TRIP REL
I (1)
K1-1 GAS GRILL/GRIDDLE
K (2)
RESERVED FOR SHUNT TRIP
2
50
1
20
1
1
1
2
20
20
20
30
K5
THE TIME CLOCK SHALL PROVIDE 365 DAYS, ADVANCE HOLIDAY, ASTRONOMICAL
PROGRAMMABLE SHUT OFF SWITCH AND 0-2 HOURS MAXIMUM OVERRIDE SWITCH
THE TIME CLOCK CAN BE INTERMATIC ET 7000 SERIES.
THE TIME CLOCK SHALL HAVE BATTERY BACKUP 78 HOURS MIN.
TIMER CONTROL FOR SIGNS AND LIGHTS
K
TOASTER
K12-1 ICED TEA BREWER
K3, K4 DUMP STATION / LAMP
RESERVED FOR SHUNT TRIP
P8
ICE MAKER
H1,H2 HOOD AND ANSUL PANELS
K9
REFRIG. SANDWITCH PREP.
RESERVED FOR SHUNT TRIP
K10
REFRIG. SANDWITCH PREP.
SCALE: N.T.S.
(2)
NOTE
K
I (1)
K (2)
BEFORE BIDDING FOR THE PROJECT, THE TENANT'S FIRE PROTECTION
CONTRACTOR SHALL VERIFY WITH THE LANDLORD'S ON-SITE
REPRESENTATIVE THE TYPE OF FIRE LIFE SAFETY SYSTEM TO BE USED,
FURNISHED AND INSTALLED.
K (2)
RESERVED FOR SHUNT TRIP
R
OFFICE OUTLETS
WALK-IN FREEZER
M
K8
ØA
ØB
ØC
14.57 14.00 14.47 TOTAL CONNECTED KVA
117
122
121 TOTAL CONNECTED AMPS
NORLAKE
8.3
1.00
-
C/P
KOLD LOCKER
-
-
-
-
-
-
KOLD LOCKER
WALK-IN FREEZER W/FLOOR AND SELF CONTAINED
CONDENSER
-
-
-
-
-
-
REFRIGERATED SANDWICH TABLE W/ CASTERS
(27 IN)
REFRIGERATED SANDWICH TABLE W/ CASTERS
(48 IN)
115
1
4.9
0.60
-
C/P
115
1
8.6
1/3
C/P
D-25
2 - 5 GALLON BOWL LEMONADE DISPENSER
115
1
-
C/P
L T B103
AUTOMATIC ICED TEA BREWER
120
1
15
R2N ULTRA
FOOD PROCESSOR
120
1
7.0
-
K8
1
X
NORLAKE
K9
2
X
TRUE
T SSU- 27- 12 M
K10
1
X
TRUE
T SSU- 48- 18M
K11
1
X
CRATHCO
K12-1
1
X
LIPTON
K14
1
X
ROBOT COUPE
P 1-1
1
X
CORNELIUS
2323
POST MIX DISPENSER, ICE BIN W STAND (CB2323)
120
1
3.5
1.00
-
C/P
P 1-2
1
X
PEPSI
PEPSI
CARBONATOR & WATER FILTER PACKAGE
120
1
7.0
0.85
-
C/P
P2
1
X
PEPSI
PEPSI
BAG IN BOX W/ SHELVES & LINES
120
1
6.2
0.80
-
-
P8
1
X
MANITOWOC
I-450
ICE MAKER
115
1
13.2
1.50
-
C/P
P 14
1
X
A.O. SMITH
DEL-50
WATER HEATER
480
3
-
12
0.65
5.5
1.8
-
H
CONTACT FROM
FIRE DETECTION
SYSTEM.
SV
N
(2) PROVIDE THIS BREAKER WITH SHUNT TRIP DEVICE.
(3) ROUTE THESE LIGHT CIRCUITS THROUGH TIME CLOCK.
GAS SOLENOID
VALVE
CONNECTED (KVA)
FACTOR
LIGHTING
120
4.10
125%
5.13
CONV. OUTLETS
120
6.90
100%
6.90
MISC.
120
1.50
100%
1.50
18.54
65%
12.06
MOTORS
208
12.00
125%
15.00
MOTORS
480
4.02
125%
5.03
WATER HEATER
480
12.00
65%
7.80
AIR CONDITION
480
9.00
100%
9.00
45 KVA
---
100%
68.06
TOTAL
1.50%
ANSUL
SYSTEM
CONTROL
PANEL
DEMAND (KVA)
120/208
480
---
SPEAKER/STROBE WITH UNIT
VERIFY LOCATION.
DUCT SMOKE
DETECTOR
VOLT
18
TO HOOD CONTROL
PANEL FOR FAN
SHUT DOWN
TOTAL DEMAND LOADS
DEMAND CURRENT/Ø
DESIGNED PANEL "A"
DESIGNED TRANSFORMER
=
=
=
=
CONTACT
LOCATED IN
ANSUL SYSTEM
CONTROL HEAD.
c
(1)
TO A/C FAN
CONTROL CIRCUIT
(CONTRACTOR TO
VERIFY)
HEAT DET.
VERIFY LOCATION.
Z
A-28 (2)
TO LANDLORD'S
JB FOR CENTRAL
ALARM,
1
SPARE
NOTES:
1
ALL WIRING SHALL BE #12 THWN IN 1/2"
CONDUIT.
ANSUL SYSTEM WIRING DIAGRAM
(2)
GAS SUPPLY SOLENOID
VALVE
SHUNT TRIP BREAKER
USED FOR UNDER HOOD
COOK DEVICES. AS
REQUIRED
NO SCALE
0.68
---
RELAY SQ.-"D" CLASS 8501
TYPE XM040-VO2 120 VAC
COIL, NEMA 1 ENCLOSURE,
CLASS - 9991-UE7.
PULL STATION
(1) SEQUENCE OF OPERATION: UPON ACTIVATION OF THE ANSUL SYSTEM, AND/OR FIRE
DETECTION SYSTEM. ALL EQUIPMENT UNDER HOOD, AHU FAN AND GAS SUPPLY
SOLENOID VALVE SHALL AUTOMATICALLY SHUT OFF. EXH FANS SHALL BE LOCKED IN
"ON" POSITION.
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
(2) COORDINATE WITH THE LANDLORD AND TIE IT TO THE LANDLORD'S CENTRAL
ALARM SYSTEM IF REQUIRED. COORDINATE WITH LANDLORD'S FIRE CONTRACTOR
FINAL CONNECTION TO LANDLORD'S SYSTEM MUST BE BY LANDLORD'S
CONTRACTOR AT TENANT'S EXPENSE.
63.10
120/208, 3Ø POWER SUPPLY CALCULATIONS:
1.
2.
3.
4.
X
1
(1) PROVIDE LOCK TAB AT THESE BREAKERS IN "ON" POSITION.
LOAD
OTHERS
1
120
WALK-IN COOLER W/FLOOR AND SELF CONTAINED
CONDENSER
A-10 (2)
LOAD ANALYSIS
XFRMR LOSSES
K7
-
SPRINKLER SYSTEM MUST BE FACTORY
MUTUAL COMPLIANT.
J
LANDLORD'S FA
SYSTEM BOX
6.40 10.20 7.45 TOTAL
(4) ROUTE THIS CIRCUIT WITH ISO. GROUND CONDUCTOR.
KITCHEN EQUIP.
KI TCHEN EQUI PME NT
BLDG: CHARLEY`S PHILLY STEAKS KITCHEN
PHASE: 3, S/N
WIRE: 4
WITH ISO. & EQUIP. GROUND BUSSES
MLO: N/A
(1) (3) L
SPARE
P LUMBING EQUIP.
A.I.C.: 22,000 AMPS
VOLTS: 120/208 V
MCB: 150 AMP
PHILADELPHIA, PA 19154
WIRE: 4
MF G.
ELECTRICAL
1455 FRANKLIN MILLS CIR,
PHASE: 3, S/N
WITH GROUND BUSS
NE W EXIST.
SP ECI F I CAT I ON
SPACE 852A ~ 818 SQ. FT.
BLDG: CHARLEY`S PHILLY STEAKS KITCHEN
I T EM
MARK QT Y .
E L ECT RONIC COMPONE NT EQUIPMENT
MLO: N/A
PANEL A-10
MECH
A.I.C.: 10,000 AMPS
VOLTS: 277/480 V
MCB: 100 AMP
TIME CLOCK "TC"
365 DAYS ASTRONOMICAL
PROGRAMMABLE
PHILADELPHIA MILLS
XX
PANEL "H"
TYPICAL SHUNT TRIP RELAY CONTROL
40.59 KVA
113
AMPS @ 120/208V,3Ø
150 AMP MCB, 120/208V, 3Ø, 4W.
45 KVA
TENANT
SPACE
ELECTRICAL ROOM
NO SCALE
45 KVA DRY TYPE XFRMR.
480 V. "DELTA" PRIMARY
120/ 208 V. "WYE"
SECONDARY
277/480, 3Ø POWER SUPPLY CALCULATIONS:
=
T/C
M
5
2
3
(4)-#3, CU, 1-#8, CU,
GRND IN 1-1/4"C.
1
2
PANEL
"H"
2
100 AMP
MCB
COLD WTR
METAL
PIPE
PANEL
"A"
1 # 6, CU, TO GRND, BLDG. STEEL
AND COLD WTR METAL PIPE PER
N.E.C. #250.
7 DAY, 24 HRS
PROGRAMMABLE TIME
CLOCK T/C
2
INSTALL GROUNDING SYSTEM TO COMPLY WITH RISER DIAGRAM AND WITH
N.E.C. STD. #250, REQUIREMENTS.
3
FURNISH AND INSTALL NEW PANELS "H" AND "A" IN COMPLIANCE WITH THE
RISER DIAGRAM AND PANEL SCHEDULES. ALL PANELS SHALL BE WITH
BOLTED TYPE BREAKERS.
EF-2
2
2
150 AMP
MCB
4
INSTALL POWER FEEDERS FROM PANEL "H" TO THE XFRMR AND FROM XFRMR TO
PANEL "A" AS SHOWN ON THE RISER DIAGRAM.
5
FURNISH AND INSTALL A 45KVA XFRMR AS SHOWN. THE XFRMR SHALL BE DRY
TYPE WITH 6 STANDARD VOLTAGE REGULATION TAPS. THE NEUTRAL OF THE
TRANSFORMER SHALL BE BONDED WITH THE BUILDING STEEL AND TO THE
INCOMING COLD WATER METAL PIPE WITH EXOTHERMIC WELD CONNECTIONS AS
SHOWN ON THE RISER DIAGRAM. SUPPORT THE XFRMR ABOVE THE PANELS AS
RECOMMENDED BY THE MANUFACTURER.
SF-1
HOOD
CONTROL
PANEL
2
RISER DIAG. NOTES:
THE CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AND SHALL
FURNISH AND INSTALL DISC. SWITCH AND ELECTRIC METER AS SHOWN AND
AS REQUIRED. FURNISH AND INSTALL NEW POWER SUPPLY FEEDERS AND
CONDUIT TO COMPLY WITH THE RISER DIAGRAM AND N.E.C. CODE
REQUIREMENTS.
2
3
ELECT POWER RISER DIAGRAM
1
EF-1
4
Z
1
2
45
KVA
3 #4, CU, 1#8, CU, GRND,
IN 1" C.
100AF
COORDINATE W/ LL AND
PROVIDE 100A FUSED
DISC. SWITCH AND METER
AS REQUIRED FOR TENANT
SPACE FOR 100A, 480V,
3Ø, SERVICE
2
Z
A-28 (FOR HOOD CONT.
AND LTS)
1
Z
Z
TO FAN CIRCUITS
J. BOX ON HOOD #1
LTS. & FAN SWITCH.
Z
J
Z
J
TO ANSUL
PANEL
NOTES:
(#10)
4. DESIGNED POWER SUPPLY
4
4-#1/0, CU, 1- #6, CU, ISO.
GRND, 1-#6, CU, GRND IN 2"
C.
(#10)
=
5
EXIST LL'S WIREWAY
Z
3. DESIGNED PANEL "H"
63.10 KVA
76 AMPS @ 277/480V,3Ø
100 AMP MCB, 277/480V, 3Ø, 4W.
100 AMPS, 277/480V, 3Ø, 4W.
Z
=
=
(#10)
1. TOTAL DEMAND LOADS
2. DEMAND CURRENT/Ø
J. BOX ON HOOD #2
LTS. & FAN SWITCH.
1
CONTROL WIRING SHALL BE #12 THWN IN 1/2" CONDUIT
UNLESS NOTED OTHERWISE.
2
PROVIDE NEMA 3R DISC SWITCHES FOR FANS AND ROUTE
POWER CIRCUITS FROM HOOD PANEL TO ALL FANS.
HOOD WIRING DIAGRAM
NO SCALE
PANEL SCHEDULES,
RISER DIAGRAM
AND DETAILS
E2.0
BIDDERS QUALIFICATIONS AND INSTRUCTIONS:
1.1.1
QUALIFICATIONS:
ALL INSULATED CONDUCTORS SHALL BE UNCOATED COPPER OF 98% CONDUCTIVITY, 600 VOLT AC, DUAL
RATED, TYPE THHN/THWN AS NECESSARY TO MEET THE DESIGN REQUIREMENTS AND THE APPLICABLE
CODES. THW (FOR # 4 AWG AND LARGER) AND THERMO PLASTIC WIRES RATED FOR 75 DEGREES
CENTIGRADE OPERATIONS IN WET AND DRY LOCATIONS AND 90 DEGREES CENTIGRADE WITHIN ELECTRIC
DISCHARGE LIGHTING EQUIPMENT MAY BE USED. CONDUCTORS NUMBER # 10 AWG AND LOWER SHALL BE
SOLID COPPER AND #8 AWG AND ABOVE SHALL BE STRANDED COPPER. THE MINIMUM SIZE OF WIRE
SHALL BE # 12 AWG FOR 20 AMP BREAKER, # 10 AWG FOR 30 AMP BREAKER, # 8 AWG FOR 40 AMP
BREAKER.
THE BIDDERS SHALL BE QUALIFIED, EXPERIENCED, AND LICENSED ELECTRICAL CONTRACTORS. THEY
MUST BE FAMILIAR WITH ALL FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, RULES, AND
REGULATIONS THAT MAY, IN ANY MANNER, AFFECT THE TASK.
1.1.2
BIDDING INSTRUCTIONS:
BEFORE SUBMITTING THE BID, THE BIDDERS MUST REVIEW THE TENANT INFORMATION AND CRITERIA
MANUAL, SPECIFICATIONS, PLANS, DRAWINGS, AND ALL OTHER CONDITIONS AND REQUIREMENTS THAT
MAY, IN ANY MANNER AFFECT THE WORK UNDER CONTRACT. THEY MUST VISIT THE SITE OF THE
PROPOSED PROJECT TO FAMILIARIZE THEMSELVES WITH THE LOCAL CONDITIONS, FIRE RATING
REQUIREMENTS, AND THE NATURE OF THE PROJECT. THE PRICING SHALL BE BASED ON THESE
SPECIFICATIONS AND THE MATERIALS SHOWN ON THE DRAWINGS. SUBMISSION OF THE BIDS SHALL BE
CONSIDERED AS THE EVIDENCE THAT THE BIDDER IS FAMILIARIZED TO ALL THE FACETS OF THE
SPECIFIED PROJECT. CONTRACTOR SHALL USE APPLICABLE SECTIONS OF THIS SPEC.
1.1.3
1.1.4
2.5
1.2
THE ELECTRICAL CONTRACTOR REQUIREMENTS AND INSTRUCTIONS:
1.2.1
THE CONTRACTOR SHALL USE EXPERIENCED AND SKILLED PERSONS TO PERFORM ALL THE ELECTRICAL
INSTALLATION WORK UNDER THE CONSTANT SUPERVISION OF LICENSED ELECTRICIANS AND/OR
LICENSED JOURNEYMAN ELECTRICIANS.
1.2.2
THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS, PAYING ALL FEES,
AND PROVIDING ALL NECESSARY INSPECTIONS INCIDENTAL TO THE ELECTRICAL PORTION OF THE
WORK.
1.2.3
THE CONTRACTOR SHALL BE RESPONSIBLE FOR CARRYING NECESSARY INSURANCE AS REQUIRED BY
LAW TO PROTECT EMPLOYEES, OTHER PERSONS, EQUIPMENT, AND MATERIAL.
1.2.4
THE INSTALLATION WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL BUILDING
CODES. APPLICABLE CODES, AS A MINIMUM, WILL INCLUDE THE LATEST EDITION OF THE FOLLOWING.
THESE WILL BE CONSIDERED PART OF THE SPECIFICATION OF THIS PROJECT.
2.7
IN CASE OF SUBSTITUTIONS THE CONTRACTOR SHALL PROVIDE A WRITTEN REQUEST TO THE
ARCHITECT FOR HIS REVIEW . THE CONTRACTOR SHALL IDENTIFY CLEARLY THE DIFFERENCE BETWEEN
THE SPECIFIED ITEMS AND THE SUBSTITUTE ITEMS, INCLUDING THE ECONOMIC IMPACT ON THE
PROJECT. THE SUBSTITUTE ITEM SHALL NOT BE ORDERED OR USED UNLESS APPROVED BY THE
ARCHITECT AND/OR BY THE OWNER IN WRITING.
2.8
C.
D.
LIGHTING FIXTURES, DIMMERS, LAMPS, AND SAFETY SWITCHES.
TRANSFORMERS, SWITCH BOARDS, DISTRIBUTION PANELS , DISCONNECTS, AND WIREWAYS IF
PURCHASED NEW.
METER CENTERS, CIRCUIT BREAKERS, FUSES, MOTOR STARTERS IF PURCHASED FOR THIS PROJECT.
TIME CLOCK AND OTHER DEVICES. E) SCHEMATIC DIAGRAMS FOR THE ABOVE ITEMS.
THE CONTRACTOR SHALL PROVIDE FOLLOWING DOCUMENTS BEFORE THE CLOSING OF THE PROJECT
AND PRIOR TO THE FINAL PAYMENT:
A.
B.
C.
D.
1.2.9
ALL SLAB OR ROOF PENETRATIONS SHALL BE MADE WITH APPROVED FIRE RATED SMOKE BARRIER
FITTINGS. PROVIDE ACCESSORIES (PITCH POCKETS, SLEEVES, ETC.) AS REQUIRED.
CONDUITS:
3.10
JUNCTION BOXES FOR NEON SIGN LIGHTS, SWITCHES, LIGHTING FIXTURES, RECEPTACLES AND FOR
PULLING WIRES SHALL BE AS APPROXIMATE AS SHOWN ON THE PLANS BUT EXACT LOCATIONS SHALL BE
GOVERNED BY THE ARCHITECTURAL PLANS.
3.11
ALL OUTLET BOXES SHALL HAVE SQUARE CUT CORNERS. AIR SPACE GREATER THAN 1/8" AROUND OUTLET
BOXES, AND ADJACENT DRYWALL WILL NOT BE PERMITTED. THE CONTRACTOR SHALL COORDINATE WITH
DRYWALL INSTALLER PRIOR TO INSTALLATION. CAULK AROUND BOXES TO ELIMINATE STEEL OUTLET.
2.9
OUTLET BOXES AND FITTINGS:
2.12
3.14
THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LUMINARIES, DEVICES, AND EQUIPMENT AS
SPECIFIED AND SHOWN ON THE PLAN DIAGRAMS. PROVIDE ALL CABLES, CONDUCTORS, CONDUITS, AND
CONNECTIONS AS REQUIRED TO PROVIDE COMPLETE AND OPERATIONAL ELECTRICAL AND MECHANICAL
SYSTEMS. ALL CONDUITS SHALL BE RUN CONCEALED IN FINISHED AREAS.
3.16
BRANCH CIRCUITS SHALL BE ARRANGED USING DOUBLE ROW CONSTRUCTION. ALL INTERIORS SHALL BE
COMPLETELY FACTORY ASSEMBLED WITH SWITCHING AND PROTECTIVE DEVICES, WIRE CONNECTORS, ETC.
ALL WIRE CONNECTORS, EXCEPT SCREW TERMINALS, SHALL BE OF THE ANTI-TURN SOLDERLESS TYPE AND
ALL SHALL BE SUITABLE FOR COPPER WIRE OF THE SIZES INDICATED ON DRAWINGS OR IN THE PANEL
SCHEDULES AND CONTINUOUSLY FUNCTIONING AT 75 DEGREE CENTIGRADE.
INTERIORS SHALL BE SO DESIGNED THAT SWITCHING AND PROTECTIVE DEVICES CAN BE REPLACED
WITHOUT DISTURBING ADJACENT UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS AND
SHALL BE SO DESIGNED THAT CIRCUITS MAY BE CHANGED WITHOUT MACHINING, DRILLING, OR TAPPING.
BUS BARS FOR THE MAINS SHALL BE OF COPPER AND SIZED IN ACCORDANCE WITH UNDERWRITERS'
LABORATORIES STANDARDS. UNLESS NOTED OTHERWISE, FULL SIZE NEUTRAL BARS SHALL BE INCLUDED.
BUS BAR TAPS FOR PANELS WITH SINGLE POLE BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING
OF THE BRANCH CIRCUIT DEVICES.
THE SHORT CIRCUIT RATING OF THE ASSEMBLED PANEL BOARD SHALL BE IN ACCORDANCE WITH UL. INC.
STANDARDS AND THEIR TEST VERIFICATION.
PHASE BUSSING SHALL BE FULL HEIGHT WITHOUT REDUCTION. CROSS AND CENTER CONNECTORS SHALL
BE COPPER.
NEUTRAL AND GROUND BUSSING SHALL HAVE SUITABLE LUGS FOR OUTGOING FEEDERS REQUIRING A
NEUTRAL AND GROUND CONNECTIONS.
INDIVIDUAL BREAKERS WILL SUPPLY ELECTRICAL POWER TO INDIVIDUAL SIGN OR NEON LIGHT CIRCUITS.
NEON TRANSFORMER EQUIPMENT IS TO BE CONCEALED ABOVE ADJACENT COLUMN ENCLOSURE OR TO BE
INSTALLED AS SHOWN ON ARCHITECTURAL DRAWINGS.
ALL JOINTS IN CONDUIT AND RACEWAY SHALL BE MADE TIGHT AND BENDS SHALL BE MADE OVER LONG
RADIUS WHERE ENTERING A CABINET AND JUNCTION BOX. THE CONTRACTOR SHALL SUPPORT ALL
CONDUIT AND RACEWAYS SECURELY FROM JOISTS AND/OR BEAMS (TIE WIRES ARE NOT ACCEPTABLE). THE
CONTRACTOR SHALL VERIFY ALL RACEWAY SIZES IN ACCORDANCE WITH THE N.E.C. CODE. NO CONDUIT
SHALL CARRY MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS. NOTE: ALL JOB CUT THREADS
SHALL BE COATED WITH RUST RESISTANT ZINC CHROMATE FOR THIN WALL EMT.
SPACES FOR FUTURE SWITCHING AND PROTECTIVE DEVICES ON LIGHTING AND APPLIANCE DISTRIBUTION
PANELS SHALL BE BUSSED FOR THE MAXIMUM DEVICE THAT CAN BE FITTED INTO THEM.
PROVIDE BLANK FILLER PLATES IN THE EMPTY SPACES.
4.2
TIME CLOCK SHALL BE ELECTRO-MECHANICAL 24 HOURS SEVEN DAYS TYPE WITH RESERVE POWER AND
CONTACTS RATED 40 A. 4 PST AND N.E.M.A. TYPE 1 OR 3R ENCLOSURE. IT SHALL BE SELF POWERED BY A
SELF STARTING SYNCHRONOUS MOTOR WITH MINIMUM 16 HR SPRING DRIVEN RESERVE POWER AND A
DAY OMITTING DEVICE. TIME CLOCK SHALL BE PARAGON 7007-0, TORK "W" SERIES, OR APPROVED EQUAL.
3.17
LIGHTING CONDUITS SHALL BE SUPPORTED AT EVERY 8 FEET.
3.18
MOUNTING HEIGHT OF LIGHTING EQUIPMENT, UNLESS NOTED OTHERWISE ON ARCHITECTURAL PLANS
SHALL BE APPROXIMATELY AS FOLLOWS:
HANDLES INDICATING "ON" "OFF" AND "TRIPPED" CONDITION.
3.19
3.20
3.21
A.
LIGHTING SWITCHES CENTERLINE
B.
CONVENIENCE OUTLETS CENTERLINE
C.
LIGHTING & POWER PANELS TOP
D.
EMERGENCY LIGHT FIXTURES
EACH POLE SHALL PROVIDE INVERSE TIME DELAY AND INSTANTANEOUS CIRCUIT PROTECTION. THE
BREAKER RATING AND CONFIGURATION SHALL BE AS INDICATED ON THE PANEL BOARD SCHEDULE. ALL
MULTI POLE BREAKERS SHALL HAVE AN INTERNAL COMMON TRIP.
4 FEET ABOVE A.F.F
ALL BREAKER LUGS SHALL BE SUITABLE TO WITHSTAND 75 DEGREE CENTIGRADE WITHOUT
MALFUNCTIONING.
1 FEET, 6 INCHES A.F.F
6 FEET, 6 INCHES ABOVE A.F.F
4.3
9' ABOVE A.F.F TO BOTTOM OF THE UNIT.
GUARANTEE:
3.22
ELECTRICAL RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.),
ARTICLE 250. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH
CONDUIT RUN. ISOLATED GROUND CONDUCTORS SHALL BE ROUTED TO THOSE CIRCUITS WHICH NEED
ISOLATED GROUND SPECIALLY FOR COMPUTERS AND CASH REGISTERS.
1.
2.
THE CONTRACTOR SHALL PROVIDE LIGHTNING PROTECTION VOLTAGE SURGE PROTECTOR FOR ALL
SERVICE PHASE CONDUCTORS TO GROUND (IF IT IS NOT ALREADY THERE IN CASE OF RENOVATIONS).
DEVICE SHALL BE APT TE 400 OR APPROVED EQUIVALENT.
INSTALLATION INSTRUCTIONS:
3.1
GENERAL:
THE PLAN LOCATION OF LIGHTING FIXTURES, JUNCTION BOXES, CONVENIENCE OUTLETS, AND PANEL
BOARDS ARE APPROXIMATE UNLESS DIMENSIONED AND ARE TO BE ADJUSTED BY THE CONTRACTOR AS
REQUIRED IN THE AREAS WHERE CEILING GRID AND OTHER OBSTRUCTIONS DETERMINE FIXTURE
LOCATIONS. THE CONTRACTOR SHALL COORDINATE WITH OTHER ARCHITECTURAL, MECHANICAL AND
OTHER SYSTEMS TO AVOID INTERFERENCE. ALL CUTTING AND CONSEQUENT REPAIRS IN CONJUNCTION
WITH THE WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. BEAMS OR OTHER STRUCTURAL
COMPONENT SHALL NOT BE CUT WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT.
3.3
THE ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE CODES AND SHALL
INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING. WORKMANSHIP SHALL BE THE HIGHEST
QUALITY AS ESTABLISHED BY TRADE STANDARD.
1.2.10 THE CONTRACTOR SHALL CONCEALED ALL THE CONDUIT IN THE FINISHED AREAS.
3.4
THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS AND COMMUNICATIONS
WITH THE LOCAL BUILDING DEPARTMENT AND INSPECTION PERSONNEL TO REVIEW CONTRACT
DOCUMENTS PRIOR TO INSTALLATION.
3.5
OWNER WILL NOT BE HELD RESPONSIBLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR'S ERROR
OR OMISSION OF MATERIALS OR WORKMANSHIP IN WORK PERFORMANCE.
DOORS SHALL NOT UNCOVER ANY LIVE PARTS WHILE MAKING SWITCHING DEVICE HANDLES
ACCESSIBLE.
DOORS SHALL HAVE FLUSH-TYPE CYLINDER LOCK AND CATCH, EXCEPT THAT DOORS OVER 48" IN
HEIGHT SHALL HAVE AUXILIARY FASTENERS AT TOP AND BOTTOM OF DOOR IN ADDITION TO FLUSH
-TYPE CYLINDER LOCK AND CATCH. DOOR HINGES SHALL BE CONCEALED. ALL LOCKS SHALL BE KEYED
ALIKE. DIRECTORY FRAME AND CARD HAVING A TRANSPARENT COVER SHALL BE FURNISHED ON EACH
DOOR.
THE TRIMS SHALL BE FABRICATED FROM CODE GAUGE SHEET STEEL. ALL EXTERIOR AND INTERIOR STEEL
SURFACES OF THE PANEL BOARDS SHALL BE PROPERLY CLEANED PRIMED AND PAINTED IN ACCORDANCE
WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND COLOR.
LUMINARIES SHALL BE AS SPECIFIED IN THE "LIGHTING FIXTURE SCHEDULE". ALL RECESSED AND LAY-IN
FIXTURES SHALL BE SUPPORTED FROM THE FOUR CORNERS WITH SUPPORTS CAPABLE OF CARRYING TWICE
THE WEIGHT OF THE FIXTURE. ALL SUPPORTS SHALL BE ATTACHED TO THE JOISTS AND/OR BEAMS. NO
LIGHTING FIXTURE SHALL BE INSTALLED WITHIN 2 FEET OF ANY SPRINKLER HEAD.
TRIMS FOR FLUSH MOUNT PANELS SHALL OVERLAP THE BOX BY AT LEAST 3/4" ALL AROUND. SURFACE
MOUNT PANELS TRIMS SHALL HAVE THE SAME WIDTH AND HEIGHT AS OF THE BOX. TRIMS SHALL BE
MOUNTABLE BY A SCREW DRIVER WITHOUT THE NEED FOR SPECIAL TOOLS.
PANEL BOXES:
THE CONTRACTOR SHALL INSTALL ALL TELEPHONE JACKS AND WIRING FROM THE MAIN TELEPHONE
TERMINAL BOARD TO THE FINAL TELEPHONE OUTLETS. WIRING SHALL BE INSTALLED IN A MINIMUM 1/2
INCH CONDUIT.
BOXES SHALL BE MADE FROM UNPAINTED GALVANIZED CODE GAUGE STEEL HAVING MULTIPLE KNOCKOUTS
ON THE TOP AND THE BOTTOM EXCEPT WHERE NOTED OTHERWISE. BOXES SHALL BE OF SUFFICIENT SIZE
TO PROVIDE A MINIMUM GUTTER SPACE OF 4" ON ALL SIDES.
3.23
THE CONTRACTOR SHALL COORDINATE WITH THE FIRE PROTECTION CONTRACTOR AND SHALL MAKE ALL
NECESSARY CONNECTIONS BETWEEN DUCT SMOKE DETECTORS AND HVAC UNITS.
WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED THROUGH ITS BOX TO SUPPLY
OTHER ELECTRICAL EQUIPMENT, THE BOX SHALL BE SO SIZED AS TO INCLUDE THIS WIRING SPACE. THIS
WIRING SPACE SHALL BE IN ADDITION TO
3.24
ALL JUNCTION BOXES SHALL BE ACCESSIBLE FROM BELOW. OTHERWISE, CONTRACTOR SHALL PROVIDE
ACCESS PANEL AT ALL JUNCTION BOX LOCATIONS AND SMOKE DETECTORS.
3.25
IF NOT ALREADY EXISTING, THE CONTRACTOR SHALL FURNISH ALL THE NECESSARY DISCONNECT
SWITCHES, RELAY BOXES, AND CONTROL BOXES AS REQUIRED AND RECOMMENDED BY THE HVAC
MANUFACTURER FOR THE HVAC UNIT AND WATER HEATER. THE ELECTRICAL CONTRACTOR SHALL
COORDINATE WITH THE MECHANICAL CONTRACTOR AND MAKE ALL NECESSARY CONNECTIONS TO MAKE
THE HVAC SYSTEM FUNCTIONAL.
ALL ELECTRICAL EQUIPMENT, MATERIAL AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF
ONE (1) YEAR FROM THE DATE OF ACCEPTANCE.
3.0
PANEL TRIM:
HINGED DOORS IN PANEL TRIMS SHALL COVER ALL SWITCHING DEVICE HANDLES AND SHALL CONFORM TO
THE FOLLOWING REQUIREMENTS:
4.4
2.13
CIRCUIT BREAKER:
THE CIRCUIT BREAKERS ARE TO BE INDUSTRIAL MOLDED CASE BOLT ON TYPE, STANDARD THERMAL,
MAGNETIC, WITH TRIP FREE MECHANISM, THREE POSITION
TIME CLOCK OR TIME SWITCH:
THE CONTRACTOR SHALL MAKE SURE ON A DAILY BASIS THAT ALL UNNECESSARY MATERIAL AND TRASH
CONTRIBUTED BY HIS TRADE ARE REMOVED.
THE ELECTRICAL CONTRACTOR SHALL PURCHASE AND USE ALL "NEW" MATERIAL AS SPECIFIED AND
SHOWN ON THE ELECTRICAL PLAN OF THIS PROJECT. ALL THE MATERIAL SHALL BE FREE FROM DEFECTS
AND SHALL CARRY A "UL" LABEL.
THE MOUNTING ARRANGEMENT OF EACH FIXTURE WILL BE DETERMINED BY THE CONTRACTOR EXCEPT
WHERE THE MANUFACTURER HAS GIVEN SPECIFIC MOUNTING INSTRUCTIONS.
LIGHTING DEVICES:
THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS, LABOR, TRANSPORTATION, RIGGING &
HOISTING, TOOLS, AND STORAGE, ETC. FOR ALL WORK INDICATED AND REQUIRED FOR COMPLETE
INSTALLATION.
GENERAL:
3.13
LAMPS:
3.2
2.1
A NAMEPLATE LISTING PANEL NUMBER, TYPE, MANUFACTURER'S NAME, NUMBER OF PROTECTIVE AND
SWITCHING DEVICES, VOLTAGE, CURRENT, PHASE AND AIC RATINGS SHALL BE PROVIDED.
BALLASTS:
THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY TEMPORARY ELECTRICAL
POWER, AT HIS EXPENSE, AS REQUIRED BY HIS TRADE AND BY THE GENERAL CONTRACTOR.
PRODUCTS:
LIGHTING SWITCHES AND CONVENIENCE RECEPTACLES SHALL BE FLUSH MOUNTED IN SECTIONAL SWITCH
BOXES WITH MATCHING COVER PLATES UNLESS NOTED OTHERWISE.
DEVICE PLATES:
ALL LIGHTING FIXTURES, EMERGENCY & EXIT LIGHTS SHALL BE AS LISTED ON THE LIGHT FIXTURE
SCHEDULE; HOWEVER BEFORE PURCHASING ANY LIGHT FIXTURES, SUBMIT FIXTURE. CUT SHEETS FOR THE
ARCHITECT AND THE OWNER'S APPROVAL.
ONE YEAR WRITTEN WARRANTY FOR ANY DEFECT IN WORKMANSHIP, MATERIAL, AND EQUIPMENT.
TWO SETS OF MANUFACTURER'S OPERATIONAL AND MAINTENANCE MANUALS IF APPLICABLE.
MANUFACTURER'S WARRANTIES AND WARRANTY CERTIFICATES.
TWO SETS OF REPRODUCIBLE OR RED MARKED UP PRINTS OF "AS-BUILT" DRAWINGS, ONE FOR THE
ARCHITECT AND ONE FOR THE OWNER OF THE PROJECT.
2.0
3.12
RECEPTACLES:
LAMPS SHALL BE MANUFACTURED BY SYLVANIA MODEL # SYL "FO28/841XP/SS/ECO OR EQUIVALENT. ALL
LAMPS SHALL BE GUARANTEED FOR AT- LEAST 4 YEARS OF OPERATION AFTER THE ACCEPTANCE.
PANEL BOARDS:
PANEL BOARDS SHALL BE GENERAL PURPOSE N.E.M.A. TYPE 1 OR TYPE 3R ENCLOSURES SUITABLE FOR
SPECIFIED INDOOR OR OUT DOOR LOCATIONS AND AND FLUSH OR SURFACE MOUNTING APPLICATIONS AS
INDICATED ON THE PANEL SCHEDULE. PANEL BOARDS AND THE INTERNAL COMPONENTS SHALL BE RATED
TO PERFORM THEIR FUNCTIONS CONTINUOUSLY AT 40°C AMBIENT AND 50% RELATIVE HUMIDITY. BUSSES,
TERMINALS, AND LUGS SHALL BE RATED AND CAPABLE TO FUNCTION CONTINUOUSLY AT 75 DEGREES
CENTIGRADE. PANEL BOARDS SHALL BE AS MANUFACTURED BY WESTINGHOUSE ELECTRIC CORP.,
GENERAL ELECTRIC, SQUARE 'D', CHALLENGER, OR APPROVED EQUAL.
SWITCHES AND DIMMERS:
BALLASTS FOR FLUORESCENT FIXTURES SHALL BE RAPID START, SYLVANIA ELECTRONIC ENERGY SAVING,
HIGH POWER FACTOR AND SHALL BE CLASS "P," CBM, TITLE 24 CERTIFIED WITH INTERNAL THERMAL
PROTECTOR WITH AUTOMATIC RESET AND CLASS "A" SOUND RATING NOISE LEVELS LESS THAN 30 dB
MAXIMUM. BALLASTS SHALL BE MANUFACTURED BY SYLVANIA AS SHOWN ON THE LIGHTING SCHEDULE OR
EQUAL EQUAL AND SHALL SHALL BE GUARANTEED AT LEAST FOR FIVE (5) YEARS OF OPERATION AFTER
THE ACCEPTANCE. THE BALLAST MODEL NUMBER SHALL BE "2 OR 4 LAMP PSX-SYL Xtreme AS REQUIRED".
2.10
4.1
ALL BREAKERS, SIZED AS SHOWN ON PANEL SCHEDULE, SHALL BE BOLT-ON BREAKERS.
PROVIDE DEVICE PLATE FOR EACH AND EVERY OUTLET BOX. FURNISH IN GANGS AS NECESSARY. PLATES
AND SCREWS SHALL BE GRAY UNLESS THE OWNER PREFERS SOME OTHER COLOR, AND SHALL BE OF THE
SAME MANUFACTURER AS OF THE DEVICES.
THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS FOR SPECIFIED PRODUCTS AT ONE
TIME WITHIN THIRTY (30) DAYS FROM THE OFFICIAL NOTICE TO PROCEED.
A.
B.
1.2.8
3.9
RECEPTACLE SHALL BE COMMERCIAL GRADE, 125 VOLTS AC, AND 20 AMPERE RATING WITH GROUNDED
POLE AND TWO CIRCUIT OPTION, AS MANUFACTURED BY LEVITON OR EQUIVALENT. PLATES SHALL MATCH
THE RECEPTACLES. FURNISH IN GANGS AS NECESSARY.
SHOP DRAWING SUBMITTAL SHALL BE MADE FOR THE FOLLOWING MATERIALS AND SYSTEMS:
1.2.7
SIGNAL CABLES, IF USED, SHALL BE COPPER AND SHALL MEET ALL UL AND N.E.C. CODE REQUIREMENTS.
METAL CLAD (TYPE MC), ARMORED (TYPE AC) AND NON- METALLIC (NM) CABLES SHALL NOT BE USED. ALL
CABLE ASSEMBLIES SHALL CONTAIN COPPER GROUND CONDUCTOR.
3.15
2.11
1.2.6
THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE SAME COLOR CODE IDENTIFICATION FOR EACH PHASE
THROUGHOUT THE SYSTEM FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITS.
SWITCHES AND DIMMERS SHALL BE TOTALLY ENCLOSED, RATED AT 120/277 VOLTS AC, 20 AMPS, 2000
WATTS WITH GRAY TOGGLE AND DEVICE PLATE. THESE SHALL BE QUIET OPERATION, COMMERCIAL GRADE
AS MANUFACTURED BY LEVITON, LUTRON OR EQUIVALENT. PLATES SHALL MATCH THE SWITCHES. FURNISH
IN GANGS AS NECESSARY.
A) BUILDING CODE OF THE APPLICABLE CITY AND COUNTY.
B) NATIONAL ELECTRIC CODE
NFPA 70, 2008
C) LIFE SAFETY CODE
NFPA 101, 2006
D) S.B.C.C.I. LATEST EDITION.
1.2.5
3.8
CABLE:
OUTLET BOXES, FITTING CLAMPS AND HANGERS ETC. SHALL BE GALVANIZED STEEL, RUST RESISTANT AND
COMPATIBLE WITH THE RACEWAY. OUTLET BOXES FOR FIXTURES, SWITCHES, AND RECEPTACLES SHALL
HAVE SMOOTH ROUND EDGES AND SHALL BE WITH COVER PLATES. BOXES SHALL BE "STEEL CITY" OR
EQUIVALENT. FITTINGS FOR EMT CONDUITS SHALL BE COMPRESSION TYPE. NO SET SCREW WILL BE USED.
UNUSED HOLES SHALL BE COVERED WITH APPROVED INSERT CAPS.
2.6
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL UTILITIES PLACEMENT, AS
IDENTIFIED ON THE RISER DIAGRAM, AND LOCATION OF THE ELECTRICAL SERVICE EQUIPMENT. THE
CONTRACTOR SHALL PAY ALL NECESSARY CHARGES ASSOCIATED WITH INSTALLATION OF ALL UTILITIES
TO THE POWER COMPANY PRIOR TO THE CONSTRUCTION. A LETTER SHALL BE PROVIDED FROM THE POWER
COMPANY THAT ALL THE CHARGES HAVE BEEN PAID IN FULL.
NECESSARY AND OBVIOUSLY REQUIRED, ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS,
SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO INSTALL A COMPLETE AND SAFE
ELECTRICAL SYSTEM.
THE CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND HOT DIPPED GALVANIZED STANDARD
STEEL AS MANUFACTURED BY WHEATLAND TUBE COMPANY OR EQUIVALENT.
SUCCESSFUL BIDDER:
THE SUCCESSFUL BIDDER WILL BE REFERENCED AS THE CONTRACTOR FROM THIS POINT ONWARDS
THROUGHOUT THE REST OF THE SPECIFICATION.
3.6
3.7
BID PRICE:
THE BID PRICE SHALL INCLUDE LABOR AND MATERIAL COSTS, NECESSARY INSURANCE COSTS AND
PERMITS FEES AS REQUIRED TO INSTALL THE COMPLETE ELECTRICAL SYSTEM IN COMPLIANCE WITH THE
DESIGN REQUIREMENTS OF THIS PROJECT.
1.1.6
2.4
MATERIAL TAKE OFF:
ALL MATERIAL TAKE OFFS, OTHER THAN THE EXISTING DEVICES, SHALL BE MADE USING THE LIGHT &
POWER WIRING AND CONDUIT DRAWINGS AND THEIR ASSOCIATED REFERENCES INCLUDING THE
SPECIFICATIONS OF THIS PROJECT ON THIS DRAWING. ALL LIGHTING MATERIALS INCLUDING
TRANSFORMER, PANELS, FIXTURES, SWITCHES, RECEPTACLES, WIRES AND RACEWAYS, ETC. SHALL BE
PURCHASED BY THE CONTRACTORS PER SECTION NO. 2, UNLESS NOTED OTHERWISE.
1.1.5
2.3
EXCEPTIONS:
ANY EXCEPTIONS, OMISSIONS, DISCREPANCIES, AND DOUBTS REGARDING PLANS, DRAWINGS, AND
SPECIFICATIONS, IF ANY, SHALL BE COMMUNICATED PROMPTLY IN WRITING TO THE ARCHITECT OR TO
THE ENGINEER FOR THEIR REVIEW AND RESPONSE BACK BEFORE THE BID SUBMISSION DATE. NO ORAL
COMMUNICATION REGARDING THE EXCEPTIONS OR CHANGES SHALL BE ACCEPTED. BIDDERS SHALL BE
NOTIFIED OF ANY CHANGES, IF MADE, DUE TO THE ACCEPTANCE OF EXCEPTIONS BEFORE THE BID
SUBMITTAL DATE.
CONDUCTORS:
1455 FRANKLIN MILLS CIR,
1.1
2.2
SPACE 852A ~ 818 SQ. FT.
GENERAL
PHILADELPHIA MILLS
1.0
PHILADELPHIA, PA 19154
ELECTRICAL SPECIFICATIONS AND INSTRUCTIONS FOR INSTALLATION WORK
3.26
A PLASTIC COVERED TYPE WRITTEN IDENTIFICATION CARD FOR ALL MAIN AND BRANCH CIRCUITS
INCLUDING SPARES SHALL BE POSTED AT THE INSIDE OF THE PANEL DOOR.
3.27
LOCK-ON DEVICES ON PANEL CIRCUIT BREAKERS FOR NIGHT, EXIT AND EMERGENCY LIGHTING CIRCUITS
SHALL BE PROVIDED AND THE SHALL BE GIVEN TO THE OWNER.
3.28
LOW VOLTAGE WIRING LOCATED ABOVE THE CEILING SHALL BE PLENUM RATED OR INSTALLED IN METAL
CONDUIT.
4.0
TRANSFORMER AND PANEL BOARD SPECIFICATIONS :
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
THE MINIMUM GUTTER SPACE SPECIFIED ABOVE AND THE LIMITING WIDTH MAY BE INCREASED
ACCORDINGLY. AT LEAST FOUR (4) INTERIOR MOUNTING STUDS SHALL BE PROVIDED.
ALL UNUSED HOLES IN THE BOXES SHALL BE PLUGGED WITH APPROVED INSERT CAPS. BOXES SHALL BE
"STEEL CITY" OR EQUAL.
4.5
DISCONNECT SWITCHES:
THE CONTRACTOR SHALL INSTALL N.E.M.A. TYPE 1 DISC. SWITCHES FOR INDOOR AND N.E.M.A. TYPE 3R
DISC. SWITCHES FOR OUT DOOR APPLICATIONS. ALL DISCONNECT SWITCHES FOR SERVICE CONDUCTOR
ENTRANCES SHALL BE RATED AT LEAST 100K AIC. DISCONNECT SWITCHES FOR MOTOR CIRCUIT AND FIXED
LOAD (SUCH AS HVAC EQUIPMENT, AND WATER HEATER ETC.) CIRCUITS SHALL BE FUSIBLE OR NON
FUSIBLE AS SHOWN ON THE DRAWINGS OR REQUIRED BY THE MANUFACTURER.
4.6
FUSE:
THE CONTRACTOR SHALL USE DUAL ELEMENT, TIME DELAY CURRENT LIMITING, 100,000 AMP AIC RATED,
CLASS RK-1 FUSES WHEN PROTECTING PANEL BOARDS AND TRANSFORMERS AND 100,000 AMP AIC RATED
CLASS RK-5 FUSES WHEN PROTECTING MOTORS UNLESS NOTED OTHERWISE OR REQUIRED DIFFERENTLY
BY THE MANUFACTURER. ALL FUSES IN ANY DISC.. SW SHALL BE OF THE SAME MANUFACTURER AND SHALL
BE MANUFACTURED BY BUSSMANN, GOULD SHAWMUT OR EQUIVALENT.
THIS SECTION SHALL APPLY TO THE NEW TRANSFORMER, PANEL BOARDS, CIRCUIT BREAKERS, PANEL
BOXES & TRIMS, DISCONNECT SWITCHES, AND FUSES.
ELECTRICAL
SPECIFICATIONS
E3.0
COOLING LOAD:
ROOF
818 SF x 15 ° x 0.031
= 380.37
BTUH
OUTSIDE AIR
BY MALL UNITS
=
BTUH
LIGHTING
1500 W X 3.413
= 5119.50
BTUH
PEOPLE
5
= 1250.00
BTUH
= 6749.87
BTUH
x 250
SUB TOTAL.............................
SYMBOL/NAME
WALK-IN COOLER
WALK-IN FREEZER
3 COOLERS
ICE M/C
TOASTER
GRIDDLE (GAS)
FRYER (GAS)
WATER HEATER
RADIATION
BTU/H
FACTOR
3000 W
1.0
0.50
3000 W
2200 W
1500 W
6000 W
150000 BTU
110000 BTU
12000 W
1.0
1.0
1.0
0.5
1.0
1.0
0.1
0.50
0.50
0.50
0.40
0.033
0.033
0.33
SUB TOTAL............................. =
5000.00
5000.00
3751.00
2557.50
4092.00
11850.00
3630.00
43980.73
REQ'D CFM =
(75-55) 1.085
=
43980.73
300 CFM
BTUH
BTUH
OUTSIDE AIR
BY MALL UNITS
=
BTUH
PEOPLE
5
=
10"Ø
D
BTUH
300 CFM
= 54538.45
BTUH
8X12
8X14
584 CFM 584 CFM 584 CFM
24X12 24X12 24X12
400 CFM
FAN DISCONNECT,
FACTORY WIRED
TO MOTOR.
GREASE
COLLECTOR
2152 CFM
16"Ø
40"
MIN
VENTILATED CURB
HOOD#1
(5) #10 TEK SCREWS
(4) SIDES
8"
MIN
18"
MIN
LIQUID TIGHT
FLEXIBLE CONDUIT
BY EC.
CURB
CLEARANCE FROM THE DUCT TO THE INTERIOR SURFACE OF ANY ENCLOSURE OF
COMBUSTIBLE MATERIAL SHALL BE NOT BE LESS THAN 18", AND CLEARANCE
FROM THE DUCT TO THE INTERIOR OF ANY ENCLOSURE OF NON-COMBUSTIBLE
MATERIAL SHALL NOT BE LESS THAN 6".
INSTALL PER MANUFACTURES
PRODUCT LITERATURE.
"PRODUCT DATA"
ROOF DECK
EXHAUST SYSTEM PLAN
OR TRANSVERSE JOINTS)
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
2 LAYER = 2 HOUR
ESR#1255
L 3"X3"X1/4" STEEL ANGLE
CLEARANCE PER NFPA 96
TWO SIDES OF CURB
NOTES:
1. PROVIDE CURB EXTENSION OF HEIGHT TO RAISE FAN DISCHARGE HEIGHT TO MIN.
OF 2'-0" ABOVE ANY O/A INTAKE WITHIN 10'-0".
CANTILEVER STRUT
CHANNEL AS REQUIRED
FOR REAR HOOD
SUPPORT
2'-0" MAX
2 HOUR RATED ASSEMBLY.
16 GA. GREASE DUCT
NOTE: PROVIDE SIMILAR CONSTRUCTION AROUND HOOD CONT. WELD
1 58"x1 58" 14 GA MIN. STRUT CHANNEL
BETWEEN BAR JOIST AT SUPPORT
LOCATIONS AT BOTTOM CHORD OF
EXISTING BAR JOISTS
NOTE:
2. A ROOF PROTECTION SYSTEM SHALL BE PROVIDED AND INSTALLED FOR
ALL KITCHEN EXHAUST SYSTEMS BY MECHANICAL CONTRACTOR.
10. INSTALL METAL SHIELD (OR COLLAR) TO SEAL DUCT AT POINT OF PENETRATION OF
CEILING.
11. DUCT SYSTEM SHOULD BE INSTALLED SO GREASE CANNOT BE POCKETED. THE
SYSTEM SHALL SLOPE NOT LESS THAN 14" PER FOOT TOWARD THE HOOD OR TOWARD
THE GREASE RESERVOIR. (WHERE HORIZONTAL DUCT EXCEED 75' IN LENGTH THE
SLOPE SHALL BE MIN. 1" PER FOOT.)
A/C PLAN
3M FIRE BARRIER DUCT
WRAP 615+ BLANKET
FOR GREASE DUCT
ENCLOSURE ASSEMBLIES
RATED FIRE DUCT
WRAPPING SEE
DETAIL THIS
SHEET
ANY OPENINGS IN AN ENCLOSURE WALL SHALL BE PROTECTED BY A SELF-CLOSING
DOOR OF PROPER RATING ACCORDING TO NFPA 80.
(TYP = LONGITUDINAL
3" MINIMUM OVERLAP
EXISTING
JOIST
"GREASE GUARD"
GREASE CAPTURE
SYSTEM
F
NOTE: ALL DUCT WRAP SHALL BE SEALED WITH GLASS
FLASHING BY GEN.
CONTR., COUNTER
FLASHING BY MECH.
CONTR. CAULK
WEATHER TIGHT.
METAL DUCTS SHALL BE FABRICATED FROM A MINIMUM 16 GAUGE BLACK STEEL
AND MUST BE ASSEMBLED WITH LIQUID-TIGHT WELDED JOINTS.
REINFORCE ROOF OPENING WITH 3"X3"X1/4" STEEL ANGLE AS PER TPICAL STRUCTURE
FRAMING PLAN OR AS DIRECTED BY LANDLORD.
16X12
12"Ø
A RESIDUE TRAP SHALL BE PROVIDED AT THE BASE OF EACH VERTICAL RISER.
OPENINGS LARGE ENOUGH TO PERMIT CLEANING SHALL BE PROVIDED AT
EACH CHANGE OF DIRECTION OF THE DUCT.
9.
2152 CFM
16"Ø UP TO
EF-1 ON ROOF
D
ALL DUCTS SHALL BE INSTALLED WITH OUT FORMING DIPS OR TRAPS WHICH MIGHT
COLLECT RESIDUE.
CONTRACTOR SHALL PROVIDE DUCTCLEAN OUT ACCESS DOORS AT NOT MORE THAN
12'-0" O.C. AND AT EVERY CHANGE IN DIRECTION AS PER NFPA-96.
400 CFM
8"Ø
D
400 CFM
5 TON
OVERHEAD CANOPY TYPE HOODS SHALL BE SIZED TO COMPLETELY COVER ALL
GREASE EXHAUSTING EQUIPMENT PLUS AT LEAST 6" FROM COOKING
SURFACES.
DUCT SYSTEMS SHALL NOT BE INTERCONNECTED WITH ANY OTHER BUILDING VENTILATION OR EXHAUST SYSTEMS NOR SHALL THEY PASS THROUGH FIRE
WALL UNLESS EXPRESSLY NOTED IN THESE PLANS OR AS DIRECTED BY
BUILDING REPRESENTATIVE (LANDLORD).
8.
HOOD#2
12"Ø
FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE SHALL BE INSTALLED PER THE LATEST
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND IN COMPLIANCE WITH TERMS OF ITS LISTING.
3. MINIMUM METAL GREASE CONTAINMENT BASIN SIZE SHALL BE CALCULATED
BY MULTIPLYING THE SIZE OF THE ROOF CURB BY A FACTOR OF (TWO) 2
AND ROUNDING UP TO THE NEAREST ONE (1) FOOT INTERVAL. MINIMUM
SIZE SHALL NOT BE LESS THAN 48"x48".
ALL END CUTS OR CUTS IN THE FOIL JACKET OF FIELD APPLIED GREASE DUCT ENCLOSURE SHALL BE
SEALED PER THE MANUFACTURER'S RECOMMENDATIONS.
STRUT/BEAM "U" -BOLT/CLAMP
TO SECURE STRUT TO BOTTOM
CHORD OF BAR JOIST
3" MIN.
ALL INSTALLATIONS SHALL BE COMPLETELY ACCESSIBLE FOR VISUAL INSPECTION.
EXISTING STRUCTURE
FIELD VERIFY SPACING
AND LOCATION
AT TIME OF INSPECTION, THE FIELD APPLIED OR FACTORY BUILT GREASE DUCT ENCLOSURE INSTALLATION
INSTRUCTIONS SHALL BE MADE AVAILABLE AT THE JOB SITE.
4. THE EXHAUST FAN TO BE MOUNTED WITH A HINGE KIT AND FLEXIBLE POWER
CONNECTION AND SERVICE SWITCH MOUNTED ON THE CURB
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
5. THE EXHAUST FAN SHALL HAVE FAN WHEEL ACCESS PORTS
ITEM
SUPPLY
AIR
VAV-1
2000
OUTSIDE
AIR
RETURN
AIR
400
EXHAUST
AIR
RATED FIRE WRAP DETAIL
ROOF PROTECTION & FAN TIE DOWN DETAIL &
AIR BALANCE SCHEDULE
STRUCTURAL SUPPORT
SCALE: NONE
PRESSURE
1600
FIELD DETERMINED
SCALE: N.T.S.
400
10'-0" MIN.
2000.00
2152.00
1600.00
*
2552.00
-400.00
*
TO BE DRAWN FROM MALL COMMON AREA
TO CREAT NEGATIVE PRESSURE
0.25 D (4" MIN. PER SMACNA)
MECHANICAL FIXTURE SCHEDULE
MARK
EQUIPMENT
NOTE: ALL DUCT WRAP SHALL BE SEALED WITH GLASS
FAB AND MASTIC.
A
SPIN-IN FITTING
WITH VOLUME
EXTRACTOR AND
BALANCING
DAMPER
WRAPPED
SHEETMETAL
DUCT SEE NOTE
#6 IN GENERAL
HAVC. SPECS.
VAV-1
B
SMOKE
DETECTOR
C
SUPPLY
DIFFUSER
HARD DUCT
HORIZONTAL
HARD ELBOWS
WHERE BEND
EXCEEDS 45°
DUCT
CLAMP
DUCT CLAMP
INSULATED FLEXIBLE
DUCT
SUPPLY
D
1-1/2" INSULATION WITH
VAPOR BARRIER COVERING
TOP SIDE OF DIFFUSER
FROM NECK TO CEILING
AND SEALED TO DUCT
INSULATION. (R=6.0)
FLEX DUCT INSTL. DETAIL
SCALE: NONE
SLOT
DIFFUSER
E
RETURN AIR
GRILLE
F
COOKING
EXHAUST
SYSTEM
DESCRIPTION/
MANUFACTURER/
ACCESSORIES
MODEL
FAN POWERED
VARIABLE AIR VOLUME
TERMINAL
WITH 9KW ELEC. HEATER
S/A & R/A MOUNTED & WIRED
TO SHUT DOWN HVAC UNIT &
HOOD SUPPLY AIR FAN
CFM AS SHOWN ON PLAN
W/ 8" ROUND
COLLAR W/ OPPOSED
BLADE DAMPER,
& 4 WAYS DISTRIBUTION.
CFM AS SHOWN ON PLAN
48"X8"
4 SLOT, WITH DAMPER
WITH ROUND COLLAR
NOTES
RECTANGULAR DUCT
ENVIRO-TEC
CFR SERIES
MODEL CFR EH 1421
SET FOR 2000 CFM
CONTACT LOCAL REP.
MUST HAVE DIGITAL CONTROL
SEE PLAN FOR LOCATION
SF-1
18"
MIN.
TOTAL
1752
SEE TIE-DOWN DETAIL
AND FAN STRUCTURE
SUPPORT THIS SHEET.
ROOF
note:
THE EXHAUST OUTLET
SHALL BE A MINIMUM OF
TEN (10) FEET FROM
ADJACENT BUILDINGS,
PROPERTY LINES OR AIR
INTAKES (THREE (3) FEET
ABOVE ANY AIR INTAKE
LOCATED WITHIN TEN (10)
FEET IS ALLOWED) AND
FORTY (40) INCHES AWAY
FROM ANY WALL.
1
2"
DIA. MIN. ALL
THREADED RODS
TOP OF KITCHEN HOOD
WITH CLIP ANGLES @
SUPPORT LOCATIONS
FRESH AIR INTAKE
CONICAL FITTING WITH
LOCKING TYPE VOLUME
DAMPER. OR SIDE WALL
TAKEOFF EQUAL TO
FLEXMASTER STO.
PYROTRONICS SERIES 3/3X
MODEL DI-B3 OR EQUAL
IONIZATION TYPE UNIT. VERIFY
W/L.L. FIRE ALARM SYSTEM
CONTRACTOR PRIOR TO BID
AND/OR CONST.
RATED FIRE DUCT
WRAPPING SEE
DETAIL THIS
SHEET
CLEAN OUT
ACCESS
SUSPENDED CEILING
GRID SYSTEM
STAINLESS STL CLOSURE FROM
TOP OF HOOD TO UNDERSIDE
OF CEILING- PROVIDED BY
HOOD MANUFACTURE,
INSTALLED BY G.C.
VOLUME DAMPER
SEAMLESS WELDED
EXHAUST DUCT
CONTRACTOR SHALL
PROVIDE DUCTCLEAN
OUT ACCESS DOORS
AT NOT MORE THAN
12'-0" O.C. AND AT
EVERY CHANGE IN
DIRECTION AS PER
NFPA-96.
1/4" PER FOOT
SLOPE
6"
1752
D
SF-1
MAX. 20°
TRANSITION
-400
MECHANICAL PLAN,
NOTES & DETAILS
TITUS TDC-AA
FLEX DUCT OR ROUND
SHEET METAL DUCT.
FLEX DUCT MAX. 5'-0"
LONG, USE CLAMP TO
ATTACH FLEX DUCTS
AND SEAL. SUPPORT
DUCT EVERY FOUR
FEET FROM
STRUCTURE
TITUS TBDI-30
1/2"X1/2"X1/2" CUBE CORE
CONSTRUCTION (EGG CRATE)
TITUS 355RL
SEE 'CAPTIVE AIR' SHOP
DRAWINGS (H-SHEETS)
FOR SPECIFICATIONS
ON HOOD & FAN EQUIP.
'CAPTIVE'
AIR TECH EXHAUST
SYSTEMS
DUCTED
RETURN
BRANCH DUCT DETAILS
SCALE: NONE
CEILING
44" max.
400
CONTRACTOR MUST
PROVIDE GREASE
GUARD, GREASE
CONTAINMENT SYSTEM
FOR ALL FANS
EXHAUSTING GREASE
VAPORS AT EF-1 AND
EF-2.
7'-0" A.F.F.
EF-2
-2152
9'-6"
2152
10'-0"
EF-1
1.25 D
7.
F
16"Ø
LATENT TOTAL........................ = 10557.72 BTUH
F
16X16
= 9307.72
EF-1
8"Ø
SENSIBLE LOAD x 0.25
HOOD DUCTWORK NOTES:
6.
300 CFM
12
6X
EQUIPMENT
14. A/C UNIT INSTALLATION SHALL COMPLY WITH THE MFG. SPECIFICATIONS,
LANDLORD CRITERIA, MECJANICAL CODES AND CLEARANCE REQUIREMENT FOR
SERVICING.
15. REINFORCE ROOF OPENING WITH 3"X3"X1/4" STEEL ANGLE AS PER TPICAL STRUCTURE
FRAMING PLAN OR AS DIRECTED BY LANDLORD.
5.
F
400 CFM
8"Ø UP TO
EF-2 ON ROOF
C
LATENT LOAD:
GRAND TOTAL COOLING LOAD
1752 CFM
16X16 UP TO
SF-1 ON ROOF
F
21.7
1250.00
F
EF-2
BTUH
= 2026 CFM
x 250
SF-1
F
10"Ø
THE USE OF FLEXIBLE DUCTS AT DIFFUSERS IS REQUIRED. FLEXIBLE DUCTS SHALL
NOT EXCEED 5' IN LENGTH & MAY BE USED AS THE FINAL CONNECTION ONLY.
C
BTUH
6749.87
SUB TOTAL FROM ABOVE ....
TOTAL POTENTIAL
SENSIBLE COOLING
LOAD......................................= 43980.73
PROVIDE CERTIFIED TEST AND BALANCE OF HVAC SYSTEM (AND EXHAUST SYSTEM WHERE
APPLICABLE) BY L.L. APPROVED CONTRACTOR, NO LATER THAN THIRTY (30) DAYS AFTER
SYSTEM IS INSTALLED TO ARCHITECT FOR APPROVAL BY LANDLORD.
F
1350.36
37230.86
13. ALL H.V.A.C EQUIPMENT & DUCTS SHALL BE PROVIDED WITH
VIBRATION ISOLATORS, SOUND TRAPS, DUCT LINING, ACOUSTICAL
HOUSINGS, ACOUSTICAL LOUVERS ETC.
4.
300 CFM
.
" MIN
REGISTERS, DIFFUSERS AND GRILLES SHALL BE PROVIDED IN SIZES AND LOCATIONS
AS SHOWN ON DRAWINGS. CEILING & WALL MOUNTED REGISTERS, DIFFUSERS
AND GRILLES SHALL BE EQUIPPED WITH GASKETS BEHIND FACE FLANGES,
WHICH SHALL MAKE AN AIRTIGHT SEAL BETWEEN OUTLET AND FACE OF WALL
OR CEILING. OUTLETS SHALL BE INSTALLED PLUMB, LEVEL AND PARALLEL TO
BUILDING, WALLS OR FLOORS. SUPPLY DIFFUSERS SHALL BE TITUS-PAS, OR
OR APPROVED EQUAL, WITH PERFORATED PANEL SIZED AS SHOWN ON DRWG.'S
AND WITH DEMOUNTABLE FACES WITH PATTERN CONTROLLERS OF STEEL CONST.
WITH WHITE FINISH. RETURN AND EXHAUST REGISTERS SHALL BE TITUS 50-F5
OR APPROVED EQUAL, ALUMINUM CONSTRUCTION WITH 1/2 x 1/2 x 1/2 INCH
GRID AND OPPOSED BLADE BALANCING DAMPER. FINISH TO BE WHITE.
USAGE
RATE
INPUT
12. PRIOR TO OPENING THE PREMISES FOR BUSINESS, TENANT SHALL PROVIDE L.L.
W/ WRITTEN VERIFICATION FROM AN AUTHORIZED REPRESENTATIVE OF TENANT'S
H.V.A.C. EQUIP. THAT TENANT'S NEW H.V.A.C. EQUIPMENT IS INSTALLED AND
OPERATING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
3.
18X18
R/A
T
C
18X18
KITCHEN EQUIPMENT
11. UNLESS SPECIFICALLY NOTED IN THE ARCHITECTURAL OR MECH. DRAWINGS,
ALL DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE WITHIN THE PREMISES.
ALL DUCTWORK, EQUIPMENT AND OTHER ACCESSORIES IN PUBLIC OR SALES
AREAS SHALL BE CONCEALED.
2.
CONNECT TO LANDLORD R/A DUCT,
COORDINATE LOCATION IN FIELD
WITH LANDLORD REPRESENTATIVE
B
BTUH
1420.05
~
PHILADELPHIA, PA 19154
TOTAL HEATING LOAD............=
10. MAXIMUM CONTROL SYSTEM WIRING VOLTAGE SHALL BE TWENTY FOUR (24) VOLTS
AND ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE
CODES AND LANDLORD CRITERIA.
1.
1600 CFM
R/A
VAV-1
BTUH
1455 FRANKLIN MILLS CIR,
BY MALL UNITS
1420.05
SPACE 852A ~ 818 SQ. FT.
OUTSIDE AIR
=
PHILADELPHIA MILLS
818
10'-0
9.
SF x 56 ° x 0.031
ROOF
10"Ø
8.
E
MI
N.
SHEET METAL DUCTS SHALL BE INSULATED WITH MINIMUM 1-1/2 INCH THICK
FIBERGLASS FACED DUCT WRAP BY OWENS CORNING, OR APPROVED EQUAL,
HAVING AN 'R' VALUE OF 6.0 AND FACTORY APPLIED FOIL FACING AND ONE
2 INCH FLANGE. INSULATION SHALL BE INSTALLED ACCORDING TO MFR'S.
RECOMMENDATIONS. INSULATION AND VAPOR BARRIER SHALL HAVE A FLAME
SPREAD RATING OF 25 OR LESS AND SMOKE DEVELOPMENT RATING OF 50.
~
18X18
70° Fdb
10"Ø
6.
14° Fdb,
A
SPLITTER OR BALANCING DAMPERS WHERE SHOWN, SHALL BE OF SUFFICIENT GAUGE
TO PREVENT BUCKLING OR VIBRATING, AND SHALL BE OPERATED BY A
QUADRANT DAMPER ADJUSTER WITH LOCKING FEATURES WHICH WILL HOLD
DAMPER SECURELY IN POSITION AT DESIRED SETTING.
DUCT CONNECTIONS TO EQUIPMENT SHALL BE MADE THROUGH AIRTIGHT CANVAS
OR OTHER APPROVED FLEXIBLE CONNECTIONS.
75° Fdb, 50% RH
HEATING LOAD:
DUCTWORK SHALL BE FURNISHED AND INSTALLED IN SIZES AND LAYOUT AS SHOWN.
DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. DUCTWORK SHALL
BE CONSTRUCTED OF GALVANIZED SHEET STEEL OF GAUGES AND WITH
CONNECTIONS AND BRACING IN ACCORDANCE WITH THE RECOMMENDATIONS
OF THE LATEST EDITION OF SMACNA.
5.
7.
WINTER
Fdb, 74° Fwb
'-0
"
MATERIALS, EQUIPMENT, WORKMANSHIP AND ARRANGEMENT OF WORK INSTALLED BY
THE CONTRACTOR SHALL CONFORM TO GOVERNING CODES, ORDINANCES AND
REGULATIONS OF CITY, COUNTY AND STATE, AND SHALL BE SUBJECT TO
APPROVAL OF ARCHITECT AND OR ENGINEER.
90°
AIRFLOW
4.
SUMMER
INSIDE
16X16
3.
OUTSIDE
14X16
2.
BASIS OF DESIGN:
ALL FEES, LICENSES, PERMITS AND INSPECTIONS REQUIRED BY LOCAL AUTHORITY
SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR AS A PART OF
THIS CONTRACT.
CONNECT TO LANDLORD SUPPLY AIR
DUCT, COORDINATE LOCATION IN FIELD
WITH LANDLORD REPRESENTATIVE
12X14
1.
HVAC LOAD CALCULATIONS
10
GENERAL HVAC SPECIFICATIONS:
HOOD #1
18 GAUGE
S.S.
F
EXH, HOOD,
SEE HOOD DRAWINF
SHEET H-1
FOR FRONT & EQUIP.
UNDER HOOD. SEE
ELEVATIONS
FINISHED FLOOR
SCHEMATIC EXHAUST SYSTEM DIAGRAM
SCALE: NONE
M1.0
HOOD HANGING DETAIL
SCALE: N.T.S.
FILTER COLLECTION EFFICIENCY 2" Captrate Grease-Stop Solo Filter
100
90
Ohio Selected Accounts
RESISTANCE VS. AIRFLOW - 2" Captrate Grease-Stop Solo Filter
70
1.6
RESISTANCE (in. H20)
FILTRATION EFFICIENCY (%)
80
60
50
40
30
20
1.4
1.2
1
0.8
0.6
0.4
0.2
10
0
0
0
0.1
1
PARTICLE DIAMETER (um)
200
400
600
800
1000
10
AIRFLOW (cfm)
100 E. Campus View Blvd., Suite 250, Westerville, OH, 43082 PHONE: (614) 679-7626 FAX: (919) 800-4534 EMAIL: tim.anderson@captiveaire.com
www.captiveaire.com
REVISIONS
DATE:
DWG.#:
DRAWN
BY:
SCALE:
MASTER DRAWING
* CAPTIVE-AIRE DUCT CONNECTION SIZES ARE CALCULATED USING AN EXHAUST
VELOCITY OF 1500-1800 FPM AND A SUPPLY VELOCITY OF 300-400 FPM.
CAPTIVE-AIRE HOODS ARE BUILT IN COMPLIANCE WITH:
SHEET NO.
Listed under ETL File number 3054804-001/002
SHEET NO.
100 E. Campus View Blvd., Suite 250, Westerville, OH, 43082 PHONE: (614) 679-7626 FAX: (919) 800-4534 EMAIL: tim.anderson@captiveaire.com
Ohio Selected Accounts
www.captiveaire.com
REVISIONS
DATE:
DWG.#:
DRAWN
BY:
SCALE:
MASTER DRAWING
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
21
21
22
22
23
23
24
24
SHEET NO.
100 E. Campus View Blvd., Suite 250, Westerville, OH, 43082 PHONE: (614) 679-7626 FAX: (919) 800-4534 EMAIL: tim.anderson@captiveaire.com
Ohio Selected Accounts
1
www.captiveaire.com
REVISIONS
DATE:
DWG.#:
DRAWN
BY:
SCALE:
MASTER DRAWING
NOTE:
~
2"V
C/O
* THE DOMESTIC WATER PIPING SYSTEM SHALL BE FLUSHED WITH
CLEAN POTABLE WATER UNTIL CONTAMINATED WATER DOES NOT
APPEAR AT THE OUTLET AND SHALL BE FILLED WITH A SOLUTION
CONTAINING 50 PPM OR CHLORINE AND ALLOWED TO STAND AS
REQUIRED BY CODE BEFORE FLUSHING. THE SYSTEM SHALL BE
FLUSHED COMPLETELY WITH CLEAR WATER UNTIL ALL RESIDUAL
CHLORINE CONTENT IS REMOVED. CHLORINATION SHALL BE
PERFORMED AFTER ALL PIPING AND FINAL CONNECTIONS AND
PRESSURE TESTING HAVE BEEN COMPLETED.
2
P14
T
P11-1
~
1
P1-1
P2
P6-1
P4
T
2"V
C/O
D
P5
FOR WALL CONST.
SEE ARCH. DWGS.
C/O
FLOW
CONTROL
THE WALK-IN COOLER / FREEZER
IS SELF-CONTAINED AND DOES
NOT REQUIRE A FLOOR SINK.
CLEANOUT SHALL BE SAME
DIA. AS MAIN (4" DIA.
MAX.)
P11-1
1/2" TRAP
PRIMER
C C1
1/8 BEND AT END OF
LINE CLEANOUT
2"V
C/O
DRAIN BODY
C1
WASTE LINE w/
LENGTH TO SUIT
INSIDE CAULK
P14
K12-1
DRAIN SUPPORT STRAP
PIPE
A
T
DEEP SEAL TRAP
MAIN WASTE LINE
FLOOR DRAIN DETAIL
WALL CLEAN OUT DETAIL
P8
SCALE: NONE
4
D
C
C
SCALE: N.T.S.
C/O
C1
P2
T
D
T
2"V
C/O
T
T
2"V
C/O
P5
2"V
C/O
PLUMBING EQUIPMENT NOTES:
S
4
C1 C
1
TIE-IN PLUMBING DRAIN LINES TO EXISTING LANDLORD MAIN
SANITARY WASTE LINE, CONTRACTOR TO VERIFY EXACT
LOCATION IN FIELD.
F
2
CONNECT NEW VENT LINES TO EXISTING LANDLORD MAIN VENT
LINE, CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD.
G
3
CONNECT NEW WATER LINE TO EXISTING LANDLORD MAIN SUPPLY
LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD.
FCO
FLOOR CLEANOUT - ZURN NO. Z-1444, POLISHED BRONZE ACCESS COVER, DURA-COATED CAST IRON BODY. MATCH TO PIPE SIZE.
4
INSTALL 6" PVC PIPE CHASE UNDER SLAB FOR SODA LINES FROM
BAG-IN BOX TO FRONT COUNTER, CONTRACTOR SHALL EXTEND
PIPE UNDER THE COUNTER TO SODA MACHINE LOCATION.
CO
WALL CLEAN-OUT - ZURN, #Z-1441, SMOOTH STAINLESS STEEL ACCESS COVER, DURA-COATED CAST IRON
D
P1-1
E
5
PROVIDE BACK FLOW PREVENTER AS SHOWN OR WHEREVER BACK
SIPHONAGE IS POSSIBLE.
6
FILTERED WATER TO BE SUPPLIED TO THE ICE MACHINE, SODA
RACK AND ICE TEA BREWER LOCATIONS ONLY
BODY. MATCH TO PIPE SIZE.
GENERAL PLUMBING SPECIFICATIONS:
WASTE PLAN
SCALE: 1/4" = 1'-0"
ISOMETRIC VIEW
D
FULL OPEN VALVE ON THE
DISCHARGED SIDE OF METER
F
~
E
3
WATER METER & SHUT OFF
VALVE ABOVE CEILING.
COORDINATE LOCATION IN FIELD
P11-1
P14
5
HOT WATER TO FIXTURES
AS SHOWN ON PLANS
TYPICAL SHUT-OFF VALVE
5
P6-1
1.
ALL WORK UNDER THIS HEADING SHALL BE PERFORMED AND ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH
ALL RATINGS, CODES AND STANDARDS OR OTHER AUTHORITIES HAVING JURISDICTION.
2.
ALL LICENSES, PERMITS, INSPECTIONS AND FEES REQUIRED FOR WORK UNDER THIS HEADING SHALL BE SECURED, PERFORMED AND PAID FOR BY
THIS SUBCONTRACTOR AS A PART OF HIS CONTRACT.
3.
ALL MATERIALS SHALL BE NEW, FREE FROM DEFECTS, AND FULLY EQUAL TO THE QUALITY SPECIFIED. WORK SHALL BE PERFORMED BY SKILLED
MECHANICS AND WORKMANSHIP SHALL BE FIRST CLASS IN EVERY RESPECT. CONTRACTOR SHALL HAVE A COMPETENT SUPERINTENDENT (WHO IS
EXPERIENCED IN THE WORK BEING INSTALLED UNDER THIS CONTRACT) IN CHARGE OF WORK AT ALL TIMES DURING CONSTRUCTION.
4.
ALL PIPING SHALL HAVE THE MANUFACTURER'S NAME ROLLED INTO EACH LENGTH, OR SHALL OTHERWISE BE PROMINENTLY IDENTIFIED. AFTER
CUTTING, ALL PIPE SHALL BE REAMED FULL BORE, AND ALL CUTTINGS, AND FOREIGN MATERIALS SHALL BE REMOVED BEFORE INSTALLATION.
COLD WATER SUPPLY TO
WATER HEATER
CHECK VALVE
VACUUM RELIEF VALVE,
WATTS N36-M1 OR EQUAL
THERMOMETER
6
K12-1
F
TYPICAL PIPE UNION,
DIELECTRIC IF REQUIRED
FOR DISSIMILAR METALS
COLD WATER PIPE TO
EXPANSION TANK
ELECTRIC WATER HEATER
PER SPECIFICATIONS AND
SCHEDULE
INSTALL TEMPERATURE AND
PRESSURE RELIEF VALVE
FURNISHED WITH WATER
HEATER
REPLACE HOSE BIBB WITH
GATE OR BALL VALVE FOR
DRAIN VALVE
G
SET WATER HEATER ON
PLATFORM PROVIDED BY
GENERAL CONTRACTOR ABOVE
MOP SINK
P4
SEAL FLOOR PENETRATION WITH FLEXIBLE
WATER-PROOF MATERIAL TO COMPENSATE FOR
PIPE EXPANSION
FLOOR SLAB
5. ALL SANITARY WASTE AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON, WITH FITTINGS OF THE SAME WEIGHT AS THE PIPE. THE
CONTRACTOR SHALL ENSURE THAT THE INSTALLATION OF SUCH UTILITIES DOES NOT INTERFERE WITH THE MALL STRUCTURE OR THE
OPERATIONS OF TENANTS BELOW. UNDER GROUND PIPING TO HAVE 14" PER FOOT SLOPE.
6.
FLOOR/CLG.
ASSEMBLY
ABOVE GRADE DOMESTIC WATER PIPE SHALL BE TYPE "L" SEAMLESS, HARD DRAWN COPPER TUBING AND TYPE "K" BELOW GRADE IN
CONFORMANCE WITH ASTM B88-48. FITTINGS SHALL BE WROUGHT COPPER SUITABLE FOR 200 PSI. CONNECTIONS TO DISSIMILAR MATERIALS
SHALL BE MADE WITH DIELECTRIC UNIONS. JOINTS SHALL BE 95-5 TIN ALTIMONY FOR 200 PSI. BELOW GROUND JOINTS SHALL BE BRAZED.
7. INSULATE ALL DOMESTIC WATER LINES WITH MINIMUM 1/2" FIBERGLASS INSULATION WITH AN ALL SERVICE VAPOR BARRIER JACKET WITH SEALED
JOINTS. INSULATION AND JACKET SHALL HAVE A FLAME SPREAD RATING OF NOT OVER 25 W/O EVIDENCE OF CONTINUED PROGRESSIVE
COMBUSTION AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 50.
ROUTE DRAIN PIPES TO
DISCHARGE INTO MOP SINK
WITH 6" AIR GAP
REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR MORE INFORMATION. PIPING ARRANGEMENT
SHOWN IS SCHEMATIC; ADJUST AS REQUIRED TO SUIT ACTUAL CONDITIONS. VERIFY CONNECTION
SIZES AND LOCATIONS WITH WATER HEATER FURNISHED. REFER TO FLOOR PLANS FOR PIPE SIXES.
PROVIDE SEISMIC STRAP OR BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES. PROVIDE HEAT TRAP
AND AUTOMATIC VACUUM RELIEF VALVE WHEN REQUIRED BY LOCAL AUTHORITIES.
P7-1
STUB ELBOWS ABOVE FLOOR AT LOCATIONS SHOWN
ON PLAN, 2" ON CARBONATOR AND, 2" ON DISPENSER
END: TRIM ELBOWS
PROVIDE HARD COPPER RELIEF
VALVE DISCHARGE PIPE FULL
SIZE OF VALVE OUTLET
PROVIDE DRAIN PAN WITH
SEPARATE 3/4" DRAIN TO
FLOOR SINK
SEAL TO
CABINET
WITH
SILCONE
APPROX. 12"
LENGTH AS REQUIRED
SIX INCH PVC CONDUIT AND FITTINGS WITH WELDED JOINTS. USE MINIMUM
QUANTITY OF FITTINGS. PROVIDE LONG SWEEP ELBOWS AT BOTH ENDS, WITH
MINIMUM 24" RADIUS. AVOID ELBOWS IN HORIZONTAL RUN IF AT ALL POSSIBLE.
CUT CONCRETE FLOOR SLAB & REPAIR WATERPROOFING, PATCH SLAB PER
LANDLORD'S REQUIREMENTS. GENERAL CONTRACTOR SHALL SEAL ENDS OF CONDUIT
WITH FOAM AFTER SYRUP LINE IS INSTALLED IN CONDUIT.
SODA CONDUIT
4
SCALE: N.T.S.
WATER HEATER INSTALATION DETAIL
8.
ALL FIXTURES SHALL HAVE INDIVIDUAL FIXTURE CONTROL VALVES WHICH SHALL BE CRANE, WATTS, NIBCO OR APPROVED EQUAL. VALVES OF EACH
TYPE, SUCH AS GATE OR GLOBE, SHALL BE THE PRODUCTS OF ONE MANUFACTURER. VALVES SHALL BEAR THE NAME OR TRADEMARK OF THE
MANUFACTURER AND THE WORKING PRESSURE CAST OR STAMPED ON THE VALVE BODY. MIN. 125 PSI. ALL VALVES SHALL BE ACCESSIBLE FOR
EASE OF OPERATION.
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
9. PROVIDE DIELECTRIC FITTINGS BETWEEN PIPING OF DISSIMILAR METALS AND AT WATER HEATER CONNECTIONS.
10. PROVIDE 1/2" THICK FLEXIBLE UNICELLULAR FIRE RETARDANT INSULATION ON EXPOSED LAVATORY TRAP AND EXPOSED HOT AND COLD WATER
SUPPLY AND ANY MISCELLANEOUS PIPING SUCH AS CONDENSATE PIPING. ALL JOINTS SHALL BE INSULATED AND SEALED WITH VAPOR BARRIER
CEMENT.
11. ALL PIPING, PIPE HANGERS, CLAMPS, SUPPORTS, ETC. SHALL BE FASTENED TO JOISTS OR BEAMS. WHERE PIPING IS SUSPENDED FROM STEEL
JOISTS, THE CONNECTION SHALL BE MADE AT THE TOP CHORD OF JOIST. PIPE SUPPORTS SHALL BE SPACED MO MORE THAN 10 FEET APART.
NOTHING SHALL BE ATTACHED DIRECTLY TO THE DECK, CEILING SYSTEM OR DUCT WORK ABOVE.
SCALE: NONE
12. HANGERS SHALL NOT PIERCE PIPING INSULATION VAPOR BARRIER.
13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REPAIR ANY DAMAGE DONE TO THE FIRE PROOFED STRUCTURAL STEEL SERVING THE FIRST FLOOR.
14. ALL HANGERS, RODS, BEAM CLAMPS ETC. EXPOSED TO PUBLIC VIEW SHALL BE PAINTED TO MATCH ADJACENT FINISHES AND BE MANUFACTURED
BY F&M, GRINNEL, OR CENTRAL FOUNDRY.
P8
6
G
FLOW TO
FIXTURE
P2
F
F
SYMBOL CODE
5
6
P5
COLD WATER PIPING
HOT WATER PIPING
FILTERED WATER PIPING
S
AUTOMATIC TRAP PRIMER VALVE-MOUNT IN
CW SUPPLY LINE OF FREQUENT USED
FIXTURE NEAR FLOOR DRAIN(S) SUPPLIED
12" MINIMUM TO HORIZONTAL RUN IN PIPING
5
PHILADELPHIA, PA 19154
A
P8
1455 FRANKLIN MILLS CIR,
2"V
ADJUSTABLE
DRAIN HEAD
POLISHED S.S.
ACCESS COVER
FLUSH w/ WALL
SPACE 852A ~ 818 SQ. FT.
CLEANOUT
TEE
FLOW CONTROL
VENT
P7-1
COUNTERSUNK
SCREW
P4
2"V
SLOPE FLOOR FINISH
TO DRAIN - 1/4"/FT. MIN.
PHILADELPHIA MILLS
T
2"V
C/O
P6-1
STRAINER, FLUSH
w/ FLOOR
CLEANOUT
PLUG
MAY EXTEND
AS WASTE
OR VENT
1
2"
COPPER TUBING - RUN UNDERFLOOR TO
FLOOR DRAIN(S)
15. THE CONTRACTOR SHALL ENSURE THAT ALL SLAB PENETRATIONS WITHIN THE TENANT SPACE (AND THROUGH THE ROOF) ARE PROPERLY SEALED
AND REMAIN WATERTIGHT TO PREVENT POSSIBLE WATER LEAKAGE AND/OR DAMAGE. ANY DAMAGE CAUSED FROM FAILURE TO DO SO SHALL BE A
CONTRACTOR'S SOLE RISK AND EXPENSE. ALL ROOF AND SLAB PENETRATIONS MADE BY THE CONTRACTOR ARE SUBJECT TO L.L. APPROVAL AS TO
LOCATION AND CONSTRUCTION DETAILS. ALL PENETRATIONS IN ROOF AND CEILING SHALL BE FIRE CAULKED.
16. PROVIDE CAST BRASS OR CHROME ESCUTCHEONS WITH SET SCREW DEEP TYPE, TO COVER SLEEVES OR OF A SIZE TO COVER FITTING
PROJECTIONS, PROVIDE ESCUTCHEONS FOR ALL EXPOSED PIPING THROUGH WALLS, FLOORS, AND EXPOSED CEILINGS.
17. THE CONTRACTOR SHALL CORE DRILL EXISTING FLOOR SLAB AS REQUIRED FOR INSTALLATION OF UNDERSLAB UTILITIES. CONTRACTOR MUST
COORDINATE ALL INSTALLATION OF BELOW-SLAB SERVICES WITH L.L. ALL MODIFICTIONS TO THE SLAB SHALL BE REPAIRED BY APPROVED L.L.
METHODS THAT MEET OR EXCEED THE ORIGINAL SLAB DESIGN INCLUDING WATERPROOFING. THE CONTRACTOR SHALL PROPERLY SLEEVE AND
SEAL ALL PENETRATIONS TO COMPLY WITH L.L AND CODE REQ.'S.
FLOOR SLAB
FLOOR DRAIN (SEE PLANS)
18. ALL UTILITIES NOT RE-USED SHALL BE CAPPED-OFF AND REMOVED. DISPOSAL SHALL BE PER L.L. APPROVED METHOD(S). NO UTILITES SHALL BE
ABANDONED IN PLACE.
INDIRECT WASTE PIPING
PLUMBING WATER
AND WASTE PLANS
19. CO ORDINATE ALL PENETRATIONS FLOOR, DRAINS/SINKS W/ WATERPROOFING OF SLAB
SAN. WASTE PIPING
EXIST. SAN. WASTE
PIPING
WASTE VENT PIPING
UNION
WATER PLAN
CONNECT TO EXISTING
ISOMETRIC VIEW
TYPICAL FOR ALL FLOOR DRAINS & FLOOR SINKS
UNLESS NOTED OTHERWISE ON DRAWINGS
T & P RELIEF VALVE
VALVED WATER TAP
SCALE: 1/4" = 1'-0"
P1.0
TRAP PRIMER CONNECTION IN
FLOOR DRAIN
SHUT OFF VALVE
TRAP PRIMER CONNECTION DETAIL
SCALE: N.T.S.
C1
GAS EQUIPMENT SCHEDULE
180,000
110
3/4"
110,000
122
1
1"
122,000
2"
2"
2
ANSUL PULL TIED
TO ANSUL SYSTEM
P14
2"
2"
412,000
~
412.00
TOTAL
TO MAKE-UP AIR
UNIT ON ROOF
VERIFY DISTANCE TO METER IN FIELD PRIOR TO SUBMITTING BID. COORDINATE
THE EXACT ROUTING WITH THE LANDLORD'S FIELD REPRESENTATIVE. DEMAND
PRESSURE = 10" W.C. DOWNSTREAM OF METER OR REGULATER
1"
2"
122 CFH
1
2"
2"
1-1/4"
1-1/2"
2"
1-1/2"
2"
1-1/2"
2"
C/O
2"
GAS SERVICE NOTE
2"
P4
1-1/4"
2"
THE CONTRACTOR SHALL VERIFY THE SIZE OF THE EXISTING SERVICE AND GAS METER. THE
CONTRACTOR IS RESPONSIBLE FOR REPLACING EXISTING COMPONENTS IF THEY ARE
INADEQUATE FOR THE NEW REQUIREMENTS OR INOPERABLE. COORDINATE REPLACEMENT
COMPONENT SPECIFICATIONS WITH THE LANDLORD FIELD REP. AND LOCAL UTILITY.
2"
C/O
3"
4"
C/O
3"
C C1
3"
P5
P8
P1-1
K2-1
110 CFH
3/4"
4"
TYPICAL 6" DIRT LEG
C/O
1"
1-1/4"
D
2"
C/O
C/O
2"
K1-1
4"
3"
4"
1-1/4"
P2
3"
180 CFH
NOTE:
P1-1
ALL GAS PIPING GOING TO
MOVABLE EQUIPMENT SHALL
HAVE A QUICK DISCONNECT
AND SAFETY CHAIN (SHORTER
THAN GAS LINE).
3"
FLOW
CONTROL
3/4" G WITH GAS SHUTOFF
AND QUICK CONNECT
FITTINGS TO FRYER
CONFIRM CODE RESTRICTIONS FOR LOCATING GAS PIPING IN RETURN AIR PLENUM.
ROOF- MOUNTED GAS PIPING SHALL BE INSTALLED ON FACTORY FABRICATED ROOF
EQUIPMENT SUPPORTS EVERY 5' OR AT ELBOWS. ALL GAS PIPING SHALL BE FINISHED WITH
TWO COATS OF A RUST INHIBITIVE PRIMER, ONE COAT OF FINAL PAINT (COLOR PER L.L.) AND
IDENTIFICATION LABELS.
A
1"
2"
THE SYSTEM SHALL
AUTOMATICALLY SHUT ALL
THE SOURCES OF FUEL &
HEAT TO ALL EQUIPMENT
PROTECTED BY THE SYSTEM.
SHUT-OFFS, VALVES, AND
SWITCHES SHALL REQUIRE
MANUAL RESET.
~
THE TENANT'S CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING AVAILABLE
CAPACITY, PRESSURE, SERVICE CONNECTION, UTILITY METER INSTALLATION, ETC., WITH THE
LOCAL UTILITY AND THE LANDLORD.
1
4"
2"
ALL FITTINGS USED IN CONNECTION WITH THE ABOVE PIPING SHALL BE OF MALLEABLE IRON,
YELLOW BRASS (CONTAINING NOT MORE THAN SEVENTY- FIVE (75) PERCENT COPPER)
4"
D
C/O
P7-1
1-1/4"
ALL SUCH PIPE SHALL BE EITHER NEW OR SHALL PREVIOUSLY HAVE BEEN USED FOR NO OTHER
PURPOSE THAN CONVEYING GAS. IT SHALL BE IN GOOD CONDITION AND FREE FROM INTERNAL
OBSTRUCTIONS. BURRED ENDS SHALL BE REAMED TO THE FULL BORE OF THE PIPE.
4"
4"
FLOW
CONTROL
VENT
2"
ALL PIPING USED FOR THE INSTALLATION, EXTENSION, ALTERATION, OR REPAIR OF ANY GAS
PIPING SHALL BE SCHEDULE 40 BLACK STEEL,ASTMA 120 w/150 LB. BANDED MALLEABLE IRON
SCREWED FITTINGS.
GAS CONSTRUCTION NOTES
4"
2"
2"
AUTOMATIC GAS SOLENOID
VALVE TIED TO ANSUL SYSTEM
3"
C/O
1-1/4"
MATERIAL FOR GAS PIPING
P11-1
1-1/2"
2"
1-1/2"
GAS SHUT OFF VALVE
ALL VALVES AND APPURTENANCES USED IN CONNECTION WITH THE ABOVE PIPING SHALL BE
OF A TYPE DESIGNED AND APPROVED FOR USE WITH FUEL GAS.
P6-1
2"
TENANTS REQUIRING GAS SERVICE SHALL CONTACT THE LOCAL GAS UTILITY TO MAKE
ARRANGEMENTS FOR SERVICE. IF NOT EXISTING, METERS SHALL BE LOCATED AS DETERMINED
BY THE LANDLORD. IF NOT EXISTING, PIPING FROM THE METER TO THE TENANT SPACE SHALL
BE THE RESPONSIBILITY OF THE TENANTS CONTRACTOR AS SHALL BE THE COORDINATION OF
SUCH INSTALLATION WITH THE LANDLORD. PIPING SHALL CONFORM TO ASTM-A-120
STANDARDS AND SHALL BE SCHD. 40 BLACK STEEL THROUGHOUT WITH ALL HIGH PRESSURE
CONNECTIONS GREATER THAN 2.5" DIA. WELDED. NO VALVE SHALL BE PLACED IN THE RETURN
AIR PLENUMS. DISCHARGE PRESSURE DOWNSTREAM OF THE PRESSURE REGULATOR SHALL BE
7" W.C.
PHILADELPHIA, PA 19154
MAKE-UP AIR UNIT
3/4"
2"
1455 FRANKLIN MILLS CIR,
1
180
2"
SPACE 852A ~ 818 SQ. FT.
FRYER
BTUH
PHILADELPHIA MILLS
1
GRIDDLE
K2-1
CONN.
SIZE
DISTANCE
CFH
TO METER REQUIRED
~
K1-1
EQUIPMENT
2"
~
MARK
COORDINATE WITH LANDLORD AND LOCAL
GAS COMPANY TO PROVIDE SERVICE TO THE
SPACE. INSTALL 2" GAS LINE TO GAS METER
AT ±250' DISTANCE FROM LAST PIECE OF
GAS EQUIPMENT. VERIFY DISTANCE IN FIELD
3/4" G WITH GAS SHUTOFF
AND QUICK CONNECT
FITTINGS TO GRILL
C/O
4
4
3"
C1 C
GAS PIPING ISOMETRIC
WASTE ISOMETRIC
SCALE: N.T.S.
SCALE: N.T.S.
ROOF
G
CEILING
DO NOT INSTALL VALVES IN
CEILING SPACE
GAS COCK WITH LEVER
HANDLE
EXHAUST HOOD
FULL OPEN VALVE
ON DISCHARGED
SIDE OF METER
3/4"
COORDINATE WITH LANDLORD AND LOCAL
GAS COMPANY TO PROVIDE SERVICE TO THE
SPACE. INSTALL 2" GAS LINE TO GAS METER
AT ±250' DISTANCE FROM LAST PIECE OF
GAS EQUIPMENT. VERIFY DISTANCE IN FIELD
3/4"
~
3/4"
1/2"
PIPE DROP OF SIZE AND AT
LOCATION SHOWN ON PLAN
3/4"
~
FLEXIBLE APPLIANCE CONNECTOR
FURNISHED BY OTHERS AND
INSTALLED BY PLUMBING
CONTRACTOR WITH SWIVEL JOINTS
IN BOTH ENDS. QUANTITY AND
SIZE OF CONNECTIONS AS
REQUIRED BY EQUIPMENT SERVED.
PROVIDE GAS COCK LOCATED
WHERE ACCESSIBLE BESIDE OR
ABOVE EQUIPMENT.
PLUMBING CONTRACTOR SHALL
INSTALL AUTOMATIC GAS
SHUT-OFF VALVE FURNISHED
BY OTHERS
3/4"
3/4"
E
P14
GAS PIPE HEADER ALONG WALL
BEHIND COOKING EQUIPMENT,
APPROXIMATELY 12" ABOVE
FLOOR, WITH SCREWED
FITTINGS, SIZES AS SHOWN ON
PLANS
3
1/2"
WATER METER &
SHUT OFF VALVE
ABOVE CEILING.
COORDINATE
LOCATION IN FIELD
G
FLOOR
TYPICAL 6" DIRT LEG
TYPICAL PIPE SUPPORT
ANCHORED TO WALL
TYPICAL 6" DIRT LEG
3/4"
1/2"
1/2"
1/2"
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST AS REQUIRED TO SUIT ACTUAL CONDITIONS.
ATTACH RISER AND HEADER TO WALL WITH 1" CLEARANCE BEHIND PIPE. MAKE FINAL CONNECTION TO
EQUIPMENT AS RECOMMENDED BY MANUFACTURER. INSTALL ANY GAS PRESSURE REGULATORS
FURNISHED BY FOOD SERVICE EQUIPMENT CONTRACTOR.
4410 W. MELROSE AVENUE
TAMPA, FLORIDA 33629
TEL. 813.333.2717
FAX. 813.289.3332
3/4"
1/2"
1/2"
COOKING APPLIANCE GAS PIPE
F
TO MAKE-UP AIR
UNIT ON ROOF
3/4"
~
SCALE: N.T.S.
1/2"
5
P11-1
1/2"
P6-1
3/4"
1/2"
1/2"
GAS SHUT OFF VALVE
AUTOMATIC GAS SOLENOID
VALVE TIED TO ANSUL SYSTEM
K12-1
F
G
1/2"
6
5
P4
ANSUL PULL TIED
TO ANSUL SYSTEM
3/4"
1/2"
P7-1
SYMBOL CODE
ONE BACKFLOW PREVENTER
SHALL BE LOCATED BEFORE
THE WATER FILTER AND ONE
BEFORE THE ICE MACHINE TO
PREVENT CONTAMINATION OF
THE WATER SUPPLY WHEN THE
FILTERS ARE BEING SERVICED.
1/2"
COLD WATER PIPING
HOT WATER PIPING
FILTERED WATER PIPING
1/2"
3/4" G WITH GAS SHUTOFF
AND QUICK
S CONNECT
FITTINGS TO FRYER
K2-1
INDIRECT WASTE PIPING
3/4"
SAN. WASTE PIPING
1/2"
WASTE VENT PIPING
G
F
SHUT OFF VALVE
P8
P5
UNION
1/2"
5
CONNECT TO EXISTING
3/4" G WITH GAS SHUTOFF
AND QUICK CONNECT
FITTINGS TO GRILL
GAS PLAN
SCALE: 1/4" = 1'-0"
F
ISOMETRIC VIEW
TIE-IN PLUMBING DRAIN LINES TO EXISTING LANDLORD MAIN
SANITARY WASTE LINE, CONTRACTOR TO VERIFY EXACT
LOCATION IN FIELD.
2
CONNECT NEW VENT LINES TO EXISTING LANDLORD MAIN VENT
LINE, CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD.
3
CONNECT NEW WATER LINE TO EXISTING LANDLORD MAIN SUPPLY
LINE. CONTRACTOR TO VERIFY EXACT LOCATION IN FIELD.
4
INSTALL 6" PVC PIPE CHASE UNDER SLAB FOR SODA LINES FROM
BAG-IN BOX TO FRONT COUNTER, CONTRACTOR SHALL EXTEND
PIPE UNDER THE COUNTER TO SODA MACHINE LOCATION.
WATER ISOMETRIC
5
PROVIDE BACK FLOW PREVENTER AS SHOWN OR WHEREVER BACK
SIPHONAGE IS POSSIBLE.
SCALE: N.T.S.
6
FILTERED WATER TO BE SUPPLIED TO THE ICE MACHINE, SODA
RACK AND ICE TEA BREWER LOCATIONS ONLY
6
T & P RELIEF VALVE
VALVED WATER TAP
1
ONE BACKFLOW PREVENTER
SHALL BE LOCATED BEFORE THE
WATER FILTER AND ONE BEFORE
THE SODA SYRUP RACK TO
PREVENT CONTAMINATION OF
THE WATER SUPPLY WHEN THE
FILTERS ARE BEING SERVICED.
K1-1
EXIST. SAN. WASTE
PIPING
PLUMBING EQUIPMENT NOTES:
5
P2
6
PLUMBING WATER AND
WASTE ISOMETRICS
GAS PLAN AND
ISOMETRIC
P2.0