DS Momentary Switches Door

advertisement
30852_Katalog Schalter_1-133
09.09.2003
12:22 Uhr
Seite 130
DS
Momentary Switches
Door
DS
Characteristics Long overtravel door actuation
Override facility for maintenance purposes
Available with or without a cover
Rating Up to 250 VAC, 15 A
Dimensions (mm) 48 51 16
Actuator Long overtravel horizontal plunger
Approvals UL, CSA
Preferred Range
Ordering Reference Actuating Force
(N)
(ozf)
Sealing
Operating pos.
(mm)
(in)
Terminal
Circuit
Actuator
Contacts
Electrical rating
DS1UL 13,3
48,0
IP40
14,5
0,580
Screw
CO
Plunger
Silver
Up to 250 VAC, 15 A
DS3UL 13,3
48,0
IP40
14,5
0,580
Screw
CO
Plunger
Silver
Up to 250 VAC, 15 A
130 | 131
www.saia-burgess.com
saia-burgess Switches
30852_Katalog Schalter_1-133
09.09.2003
12:22 Uhr
Seite 131
DS
Specifications
Housing
Base plate
Plunger
Mechanism
Contacts
Terminals
Temperature range
Mechanical life
Type of protection
DS3UL only - Flame retardant polycarbonate
Mild steel, zinc-plated
Stainless steel
Single pole change-over
Silver
Solder tags - Silver-plated brass - common (1), Brass - normally closed (2), normally open (4)
–10°C to +85°C
106 cycles minimum (impact free actuation)
IP40 (switch)
Circuit diagram
COMMON
2
NORMALLY
CLOSED
4
NORMALLY
OPEN
1
Dimensions DS1UL
FULL EXTENDED
POSITION
FREE
POSITION
OPERATING
POSITION
DEPRESSED
POSITION
47.6
[1.87]
31
[1.22]
12.8 MAX
[0.5]
19.05
[0.75]
46.1 MAX
[1.82]
38.1
[1.5]
8.7
[0.34]
Ø6.4
[0.25]
4.0
[0.16]
6.35
[0.25]
2
4
1
7.9
[0.31]
5 HOLES
TAPPED 4BA
40 MAX
[1.57]
FLEXIBLE
INSULATORS
Recommended maximum electrical ratings
Voltage
(max)
Resistive load
(A)
Inductive load
Horsepower
Approval
250 VAC
15 (0.75 pf)
-
-
UL 1054/CSA 22.2 No. 55 - 6,000 operations
0 - 15 VDC
15 - 30 VDC
10
7
-
-
General rating - 50,000 operations
General rating - 50,000 operations
saia-burgess Switches
www.saia-burgess.com
130 | 131
30852_Katalog Schalter_1-133
09.09.2003
12:22 Uhr
Seite 132
DS
Operating Characteristics
Actuator
Reference
DS1UL
Spring Plunger
Actuating
Force
Maximum
(N)
(ozf)
Free
Position
Maximum
(mm)
(in)
Operating
Position
Maximum
(mm)
(in)
13,3
10,5
6
48,00
0,41
Fully extended
Position
Maximum
(mm)
(in)
0,23 14,5
0,58
Depressed
Position
Maximum
(mm)
(in)
3,2
0,14
3,2
0,14
Overtravel: Plunger can be depressed flush with housing. The housing should not be used as an end stop.
DS3UL
Spring Plunger
13,3
48,00
10,5
0,41
6
0,23 14,5
0,58
Overtravel: Plunger can be depressed flush with housing. The housing should not be used as an end stop.
For the convenience of maintenance engineers who must have full working conditions with the door open, DS units are fitted with a lock-on
device which overrides the interlock while working. When the door is open, the plunger can be moved down and out to an extended position
which will cause the switches to operate. At the conclusion of the maintenance work, full interlock facilities are restored automatically when
the door is closed.
Ordering Reference
Type DS
Switch variants 1
3
Open bracket type using one miniature type insert switch
As DS1 but fitted with plastic cover
Approvals UL UL and CSA approved
132 | 133
www.saia-burgess.com
saia-burgess Switches