WA-200, WA-200-24 Automatic Wall Switch
SmartSet technology
automatically selects optimal
settings for each space
Terminal style wiring
simplifies installation
Selectable walk-through
mode for increased
savings
Choice of Auto-ON or
Manual-ON operation
Vandal resistant hard lens
Audible and/or visual alerts
of impending shutoff
PROJECT
LOCATION/TYPE
Product
Overview
Description
SmartSet
The WA-200 passive infrared automatic wall
switches turn lighting on and off based on occupancy. These switches feature our innovative
SmartSet™ technology which eliminates the
adjustment process.
Using SmartSet™ technology, the WA-200 requires
no adjustment at installation. SmartSet continuously monitors the controlled space to identify
usage patterns. Using this information, it automatically adjusts the time delay and sensitivity settings
for optimal performance and energy efficiency. The
sensor assigns short delays (as low as 7 minutes)
for times when the space is usually vacant, and
longer delays (up to 30 minutes) for busier times.
Operation
The WA-200 replaces existing wall switches. The
WA-200 operates between 100 and 300 volts, and
for low voltage applications, the WA-200-24 operates at 24 VDC/VAC. The WA uses advanced
passive infrared technology to detect occupancy
and turn lights on. Once a space is vacated and the
time delay elapses, lights automatically turn off.
DIP switch settings allow for a variety of additional
control options such as Manual or Automatic-ON,
time delay, light level sensing, sensitivity, and
audible or visual alerts.
Features
• Advanced control logic based on RISC microcontroller provides:
• Detection Signature Processing eliminates
false triggers and provides immunity to RFI
and EMI
• SmartSet automatically adjusts sensitivity and
time delay settings to fit occupant patterns
• Walk-through mode turns lights off 3
minutes after the area is initially occupied
• One-step light level control setup learns
desired hold-OFF level
www.wattstopper.com
800.879.8585
• Hard lens makes sensor resistant to vandalism
Applications
The WA-200’s hard lens enables it to be used in
public spaces such as teachers’ offices and small
storage areas in addition to standard applications of
offices, small conference rooms, copy rooms, and
other enclosed, small building spaces. The low
voltage WA-200-24, with a power pack, can switch
loads that exceed the ratings of standard wall
switches and can be used in locations where high
voltage wiring in walls is prohibited.
• Zero-cross relay control guarantees reliable
operation with non-linear loads even with temperature changes and product aging
• Terminal style wiring makes installation quick
and easy, eliminating the need for wire nuts
• Choice of automatic-ON or manual-ON operation
• Optional alerts for impending shutoff include
light flash, audible, or both
• For safety, there is no leakage to load in the off
mode and sensor is safety grounded
• Tamper resistant design
• LED indicates occupancy detection
O
c
c
u
p
a
n
c
y
S
e
n
s
o
r
s
WA-200, WA-200-24 Technical Information
Specifications
Controls
& Wiring
• WA-200: 120/230/277 VAC; 50/60 Hz operation
• WA-200-24: 24 VDC and halfwave rectified input;
current draw is 15 mA DC, 30 mA AC
• WA-200-24 contains single-pole, double-throwisolated relay rated for 1A @ 30VDC
• Coverage of 180 degrees, maximum 300 ft2, 150 ft2
for desktop activity
• Time delays: SmartSet (automatic), fixed (5, 10, 15,
20, or 30 minutes), walk-through, test-mode
Controls & Installation
• Sensitivity adjustment: SmartSet (automatic) or
reduced sensitivity
• Adjustable light level setting of 8-180 fc (86-1,937 lux)
• 1.0 mm hard, poly IR 2 lens; 2 level lens for superior desktop detection
• Compatible with all electronic ballasts and PL lamp
ballast systems
• Dimensions: 2.6" x 1.7" x 1.9"
(66.0mm x 43.2mm x 48.3mm) L x W x D
• UL and CUL listed; 5 year warranty
WA-200-24 Lighting Control Panel Wiring
Auto On/Off
Button
+24V IN (BLU)
COMM. (WHT)
DIP Switches
1
Sq
ue
2
3
4
5
6
7
PULSE OFF (BLK)
PULSE ON (RED)
LED
8
ez
eH
#20/4
To Panel
1000' MAX.
Lens
ere
To circuit
On
Off Comm
WA-200 Single Level Lighting
WA-200-24 Power Pack Wiring
White (Neutral)
Neutral
Red (Line)
Lighting
Load
White
Neut
Hot BLK
Black
Hot
Red
(Load)
Ground
RLY COMM
GRN
Blue
Black
Red
Power
Pack
Local
OFF Switch
Red
Load
24VRect
White Blue
Red Black
COMM
N.O.
+24V IN
DIP Switch Settings
Coverage
& Settings
DIP Switch #s:
Time Delay
1 2 3
DIP Switch #
SmartSet/Test
25'
(7.6m)
The 2-level lens provides
superior coverage at a desktop level by allowing the
sensor to detect vertical as
well as horizontal motion.
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
override
Disabled
Enabled
DIP Switch #
Sensitivity
Watt Stopper/Legrand®
Pub. No. 14005
Enabled
Audible Alerts
ON
FACTORY
PRESETS
1
2
3
4
5
Walk Through
6
7
8
Visible Alerts
Sensitivity
25'
(7.6m)
Factory Settings
=ON
8
Disabled
Time Delay
4
Disabled
Enabled
Catalog No.
DIP Switch #
Visible Alerts
7
On Mode
floor
Ordering
Information
6
High
Low, 50%
DIP Switch #
Walk Through
4.0'
(1.2m)
DIP Switch #
Audible Alerts
Bypass occupancy & light level functions.
Load is manually controlled with WA-200 button.
10'
(3.1m)
5
ON Mode
Auto On
Manual On
=OFF
Color
Voltage
Load Requirement
Coverage
WA-200-W
White
180°, 300 ft2 (27.9 m2)
Lt. Almond
120 VAC;
50/60 Hz
0-800 Watt Ballast
WA-200-A
WA-200-I
Ivory
or
or
WA-200-G
Grey
0-1200 Watt Ballast
WA-200-B
Black
230/277 VAC;
50/60 Hz
WA-200-24-W
White
WA-200-24-A
Lt. Almond
24 VDC/VAC
Rectified
Current: 15mA DC /
30mA AC
WA-200-24-I
Ivory
WA-200-24-G
Grey
WA-200-24-B
Black
180°, 300 ft2 (27.9 m2)
One ASP-211 single-gang cover plate included. Order ASP-422 for blank 2-gang cover plate, ASP-432 for 2-gang cover plate
with switch option (specify color).