BC80A product catalogue Answers for infrastructure. 1 Table of Contents BC80A Fire Detection Product Introduction ................................................................ 3 BC80A System Overview ............................................................................................ 6 System Load Reference .............................................................................................. 8 Addressable Control Panels ........................................................................................ BC8001A Compact Control Unit with 1 F-Bus line (127 Points) BC8001AE Compact Control Unit with 2 F-Bus lines (254 Points) BC8002A-1 Wall-mounted Advanced Control Unit (508 points) ..................................................... 9 ................................................ 9 ................................................... 10 BC8002A-2 Wall-mounted Advanced Control Unit (1,016 points) .................................................. 10 BC8002A-3 Wall-mounted Advanced Control Unit (1,524 points) .................................................. 10 Addressable Detectors and Bases ................................................................................ 11 BDS031A Addressable Heat Detector ............................................................................................... 11 BDS051A Addressable Optical Smoke Detector .............................................................................. 11 ............................................................................................ 11 ...................................................................................................... 12 BDS000A Addressable Detector Base HI520 Collective Heat Detector OP520 Collective Optical Smoke Detector ...................................................................................... 12 .................................................................................................... 12 ..................................................................................................... 13 SO520 Collective Detector Base Manual Call Points BDS121A Addressable Manual Call Point ........................................................................................ 13 .................................................................................................................. 13 ................................................................................................ 14 BDS121A-G Spare glass Addressable Modules BDS132A Addressable Input Module ............................................................................................. 14 .......................................................................................... 14 .............................................................................................................. 14 BDS221A Addressable Output Module BDS152 Isolation Module BDS161 Collective Input Module Spare Parts & Upgrades .................................................................................................... 14 .............................................................................................. 15 BCE8001A Extension Card for BC8001A ........................................................................................ 15 ............................................................................................... 15 ...................................................................................................... 15 ................................................................................................... 16 ........................................................................................................ 16 BCM8001A Line Card for BC8002A BTM8014 Mimic Display Board TP80UL-UC Printer for BC8001A TP80UL Printer for BC8002A 2 9 BCB8004 Power Supply for BC8001A .......................................................................................... 16 BCB8005 Power Supply for BC8002A .......................................................................................... 16 BT8002A Operation Panel ............................................................................................................ 16 BT8011 Interlocking Panel ............................................................................................................ 17 BT8012 Interlocking Panel ............................................................................................................ 17 UL-approved Siemens quality – reliable and economical. Your customers are responsible for the protection of their employees, buildings, and assets. They also experience cost competition. As a result, they need fire protection components that deliver reliable fire detection and alarm signaling, but which are also cost-efficient. BC80A from Siemens addresses this need with a range of reasonably priced, UL-tested fire protection products, from fire detectors to control panels. ■ Tested quality – high reliability BC80A products are certified by Underwriters Laboratories (UL). They carry the UL seal and satisfy the latest product safety requirements. With the BC80A system you can offer your customers with Siemens quality, based on in-depth research and development, state-of-the-art production technology and over 160 years of experience in fire protection. The products meet all technical safety requirements, from shortcircuit protection to immunity against electromagnetic interference. BC80A offers the flexibility that your customers need, whether they want to expand or modernize their system. Thanks to its open topology, the system is buillt for easy adaptation to growth and changing requirements. ■ Siemens technology – high cost-effectiveness BC80A combines latest technology with cost-effectiveness in both procurement and operation. Moderate hardware costs keep the investment manageable, while a flexible and expandable installation provides longterm perspective. Cost-efficiency is also assured through compatibility with existing peripheral equipment and cables. BC80A serves you with the best arguments to help your customer decide: genuine brand quality at an affordable price – for years to come. BC80A – advantages at a glance: ■ Tested and certified – according to the latest UL standard ■ High quality – based on decades of experience, in-depth research, and state-of-the-art production technology from Siemens ■ A flexible solution – expandable and compatible with future developments ■ Cost-effective – moderate investment and easy adaptation to changing requirements 3 Easy concepts make your work easier. BC80A fire protection products are easy to implement and service. They can be quickly installed and rapidly commissioned. This reduces your costs and speeds up order processing. Simplicity of design reduces the period needed to gain familiarity with the system, so you can offer your customers user-friendly fire protection in the shortest possible time. ■ Easy installation – fast protection Because the BC80A system units have been designed for easy installation, buildings can be protected quickly. BC80A provides polarity-free wiring; poles can no longer be accidentally reversed. Therefore, the networking of BC80A fire detectors, peripheral equipment, and BC80A control panels is rapid and accurate; the signal of protection always reaches its mark. 4 ■ Easy configuration – fast commissioning Commissioning of the BC80A system is supported by an integrated autoconfiguration function; with it, the system automatically detects all integrated devices (auto-mapping). This reduces manual configuration to a minimum – eliminating a potential source of error. You benefit from a shorter time to a fullyoperational system. More complex manual programming can be conducted via the control panels or by using Windows-based software. ■ Easy maintenance – no interruption of operation All devices displayed on the controllers are shown with both their address number and position details. These help your customers assess error messages as aids to decision making, and you to keep a clear overview during installation and maintenance. Tracing faulty fire detectors or peripheral devices during system operation is swift, targeted, and costefficient. ■ Easy expandability – high flexibility BC80A grows with your customers’ requirements. When buildings or rooms are extended, the BC80A installation can also be expanded, for example with new T-Branches in the cabling and extension cards in the control panels. With an extension card it is possible to hook up an additional 127 peripheral devices via the F-Bus. This increases options for larger projects. ■ Easy conversion – fast modernization Existing systems can be replaced and modernized with BC80A without large cabling expenditures. Currently installed cables can be used to network BC80A devices, since neither the fire detector lines nor the notification appliance circuits require a shielded wire. The system can also be linked with existing peripheral devices, which saves time and money. Software updates can be uploaded via the USB port of the control panels. BC80A – advantages at a glance: ■ Easy installation and fast building protection – thanks to installation aids and polarity-free non-shielded cabling ■ Fast commissioning – thanks to auto-mapping and Windows-based software ■ Minimal maintenance – address and position of detectors and peripheral devices needing service directly indicated ■ Smooth expansion – via card inserts for control panels and T-Branches for cabling Easy modernization – through use of present cabling, compatibility with existing peripheral equipment, and simple software uploads 5 BC80A System Overview BC8001AE Compact Controller B-BUS BTM8014 Mimic Display Board * BC80A A-BUS NAC Circuit BC8001AE Compact Controller Horn/Strobe Horn/Strobe BDS051A Smoke Detector BDS152 * Isolate Module F-BUS BDS031A Heat Detector BDS051A Smoke Detector BDS221A Output Module BDS121A Manual Call Point BDS031A Heat Detector BDS121A Manual Call Point BDS121A Manual Call Point BDS132A Input Module 6 BDS051A Smoke Detector A-BUS Controller Bus Max. 16 units of BC8001A/BC8002A can be networked together BC80 Configuration Tool F-BUS Device Bus Max. 127 load factors on the device bus. Flexible wiring supports free topology and free polarity FMS Graphic Station B-BUS Max. 3 B-BUS equipments ( BC8001A ) Max. 16 B-BUS equipments ( BC8002A ) NAC Circuit Connect horn/strobe BTM8014 Mimic Display Board * B-BUS Horn/Strobe Horn/Strobe NAC Circuit BC8002A Advanced Controller BDS152 * Isolate Module BDS161 * Collective Input Module BDS152 * Isolate Module BDS051A Smoke Detector FDL241-9 * Linear smoke detector BDS132A Input Module BDS121A Manual Call Point F-BUS BDS051A Smoke Detector BDS031A Heat Detector BDS031A Heat Detector BDS161 * Collective Input Module OP520 * Conventional Smoke Detector BDS051A Smoke Detector * Optional non-UL products HI520 * Conventional Heat Detector BDS121A Manual Call Point BDS051A Smoke Detector BDS031A Heat Detector BDS121A Manual Call Point BDS221A Output Module 7 System Load Reference Detectors and peripherals Type Name Load factor Quiescent current (mA) Max. current (mA) BDS031A Heat detector 1 0.8 1.0 BDS051A Smoke detector 1 0.8 1.0 BDS121A Manual call point 1 0.8 1.0 BDS132A Input module 1 1.0 3.2 BDS221A Output module 2 1.0 3.2 Name Load factor Quiescent current (mA) Max. current (mA) BDS152 Isolate module 0 0.0 1.0 BDS161 Collective input module 10 4.0 16.0 Name Load factor Quiescent current (mA) Max. current (mA) BC8001A Compact controller with 1 line card 127 185.0 400.0 BC8001AE Compact controller with 2 line card 254 197.3 372.0 BC8002A-1 Advance controller with 1 line card 508 330.0 642.0 BC8002A-2 Advance controller with 2 line card 1016 330.0 642.0 BC8002A-3 Advance controller with 3 line card 1524 330.0 642.0 Name Address point Quiescent current (mA) Max. current (mA) BT8011 Interlocking panel with 8 outputs 1 60.0 600.0 BT8012 Interlocking panel with 16 outputs 1 100.0 820.0 Optional product Type Panels and systems Type Optional function module Type 8 Panels & Systems Addressable Control Panels Type BC8001A Order No. Compact Control Unit with 1 F-Bus line ( 127 Points ) A5Q00016659 BC8001A is a control unit suitable for small to medium size projects and constructions. It has the following features: • Compatible to BDS .. A series of field devices. • Features a polarity free F-BUS with a twisted pair of wires. Transmission distance is up to 700m (Φ1.5mm2). All devices should be evenly distributed. • Specialized BDS Algorithm enhance immunity against environment disturbances. • Menu driven man-machine interface to allow simple operation. • An optional printer can be mounted into the control unit. • The system can be easily configured directly on the panel or via PC. • Configuration data can be uploaded to a PC at any time. • BC8001A features a fully supervised‚ programmable Notification Appliance Circuit (NAC) for audible and visual appliances. • Compliant with UL864 • Selectable language: Korean, Thai, Portuguese, Spanish, Traditional Chinese , Simplified Chinese, English Number of detector lines 1 Number of points 127 System Network B-Bus device Built-in printer Optional LCD Display 240 x 128‚ Backlight Auto Mapping Yes Event history 1,000 Digital I/O’s -Number of monitored OC outputs (40mA@24VDC) 1 -Number of monitored inputs 2 -Number of monitored NAC (1.5A@24VDC) 1 Input voltage (Main Power) 120/240V AC@60/50Hz (+10%, -15%) Battery capacity 12 VDC‚ 12 Ah x 2 Download/Upload USB1.1 Dimension (W x H x D) 370 x 265 x 200 mm Weight (without battery) 6.5 kg Operating temperature 0ºC... +50ºC Storage temperature -10ºC... +50ºC Relative humidity ≤93% (40±2ºC) Data sheet A5Q00016841A01 BC8001AE Compact Control Unit with 2 F-Bus lines ( 254 Points ) A5Q00021716 As BC8001A.. for technical details‚ but with the following differences: Number of detector lines 2 Number of points 254 System network Yes B-Bus device 3 © Siemens Ltd. Building Technologies Division 9 Panels & Systems Addressable Control Panels Type BC8002A-1 Order No. Wall-mounted Advanced Control Unit (508 points) BC8002A is an advanced control unit designed with new technology. It is easy for operation and commissioning. • Large LCD(10”) with high resolution 640x320 pixels. • Features a polarity free F-BUS with a twisted pair of wires. Transmission distance is up to 700m (Φ1.5mm2). All devices should be evenly distributed. • Easy operation with Windows Explorer style menu structure. • Advanced 32-bit ARM based microprocessor system. • LCD display shows the analog curve of detector measurement and allows inquires in real time fire parameters for every detection point. • Auto mapping of controller configuration makes commissioning very easy, fast and accurate. • Multi-tasking real time operating system monitors the system at any time ensure high reliability of the system. • Up to 1,000 events can be stored in the event memory. • Modular structure makes it possible to customize the system very flexibly. • Configuration of the system can be done via panel keypads or PC Tool including set parameters and logic expressions. • Powerful interlocking function fulfills complicated requirement on controls very easy. • Up to 16 control units can be interconnected via A-Bus network. Transmission distance is up to 700m with twisted pair wire (Φ1.5mm2 ). • Can be connected to management station FMS and third party system with defined communication protocol. • Common grounding trouble supervision. • Compliant with UL864. 10 BC8002A-1/en BC8002A-1/po BC8002A-1/tc BC8002A-1/sp Number of line card 1 Number of detector lines 4 Max. number of address points 508 System network Yes B-Bus device 16 Built-in printer Optional LCD Display 640×320, Backlight Auto Mapping Yes Event history 1,000 Digital I/O’s -Number of monitored OC outputs (40mA@24VDC) 2 -Number of monitored inputs 2 -Number of monitored NAC (1.5A@24VDC) 2 Input voltage 120/240V AC@60/50Hz (+10%, -15%) Battery capacity 12VDC, 38Ah x 2 Download/Upload USB1.1 Dimension ( W × H × D ) 700×520×225mm Weight (without Batteries) 21.0kg Operating temperature 0°C... +50°C Storage temperature -10°C... +50°C Relative humidity ≤95% (40±2°C) Data sheet A6V10264045 English version of BC8002A-1 Portuguese version of BC8002A-1 Traditional Chinese version of BC8002A-1 Spanish version of BC8002A-1 BC8002A-2 Wall-mounted Advanced Control Unit (1,016 points) BC8002A-2/en BC8002A-2/po BC8002A-2/tc BC8002A-2/sp The fire alarm control unit with the 2 line cards, can connect up to 1,016 points devices. English version of BC8002A-2 Portuguese version of BC8002A-2 Traditional Chinese version of BC8002A-2 Spanish version of BC8002A-2 BC8002A-3 Wall-mounted Advanced Control Unit (1,524 points) BC8002A-3/en BC8002A-3/po BC8002A-3/tc BC8002A-3/sp The fire alarm control unit with the 3 line cards, can connect up to 1,524 points devices. English version of BC8002A-3 Portuguese version of BC8002A-3 Traditional Chinese version of BC8002A-3 Spanish version of BC8002A-3 S54421-C7-A1 S54421-C5-A6 S54421-C5-A3 S54421-C7-A2 S54421-C8-A1 S54421-C5-A7 S54421-C5-A4 S54421-C8-A2 S54421-C9-A1 S54421-C5-A8 S54421-C5-A5 S54421-C9-A2 © Siemens Ltd. Building Technologies Division Detectors & Peripherals Addressable Detectors and Bases Type BDS031A Order No. Addressable Heat Detector A5Q00016746 BDS031A is heat detector which can be connected to the F-Bus. • Newly developed circuit and sensor ensure high performance of fixed and rate of rise temperature detection. • High stability against dust‚ electromagnetic interference‚ temperature fluctuation‚ humidity and corrosion. • Produced with SMT advanced technology. Operating voltage Operating temperature Storage temperature Relative humidity Quiescent current Alarm current EMC Data sheet BDS051A 18... 26 VDC 0... 38 °C -30... +75 °C ≤95 % (40 ± 2 °C) ≤0.8 mA 1.0 mA 20 V/m A5Q00016742A Addressable Optical Smoke Detector A5Q00016747 BDS051A is smoke detector which can be connected to the F-Bus. • Patented labyrinth optical structure. • New built-in ASIC ensures high reliability of data processing. • Homogeneous response to different kind of smoke. • High stability against dust‚ electromagnetic interference‚ temperature fluctuation‚ humidity and corrosion. • Produced with SMT advanced technology. Operating voltage Operating temperature Storage temperature Relative humidity Quiescent current Alarm current EMC Data sheet BDS000A 18... 26 VDC -10... +50 °C -30... +75 °C ≤95 % (40 ± 2 °C) ≤0.8 mA 1.0 mA 20 V/m A5Q00016743A Addressable Detector Base A5Q00016958 Detector base is for field devices BDS051A and BDS031A. The detector covers the whole base‚ the wiring capacity is 1.0 to 1.5mm². Data sheet © Siemens Ltd. Building Technologies Division A5Q00016963A 11 Detectors & Peripherals ntional Detectors and Bases (Collective) Type HI520 * Order No. Collective Heat Detector A6C50000009 • Newly developed circuit and sensor ensure high performance of fixed and rate of rise temperature detection. • High stability against dust‚ electromagnetic interference‚ temperature fluctuation‚ humidity and corrosion. • Produced with SMT advanced technology. Operating voltage Output voltage Operating temperature Storage temperature Relative humidity Quiescent current Alarm current EMC Data sheet OP520 * 16... 32 VDC 5... 13 VDC -10... +50 °C -30... +75 °C ≤95 % (40 ± 2 °C) ≤100 μA ≤1.5 mA 10 V/m A5Q00016379A Collective Optical Smoke Detector A6C50000010 The OP520 is an non addressable detector which can be connected in to S11 and BC80 system via corresponding collective input modules. • Patented optical structure and labyrinth. • Homogeneous sensitivity for different kind of • High stability against dust‚ electromagnetic interference‚ temperature fluctuation‚ humidity and corrosion. • Produced with advanced SMT technology. • Connection is independent of line polarity. Operating voltage Output voltage Operating temperature Storage temperature Relative humidity Quiescent current Alarm current EMC Data sheet SO520 * 21... 29 VDC 5... 13 VDC -10... +50 °C -30... +75 °C ≤95 % (40 ± 2 °C) ≤100 μA ≤1.5 mA 10 V/m A5Q00016380A Collective Detector Base A6C50000011 The detector base for field devices HI520 and OP520. Data sheet A5Q00016382A * Optional non-UL products 12 © Siemens Ltd. Building Technologies Division Detectors & Peripherals Manual Call Points Type BDS121A Order No. Addressable Manual Call Point A5Q00016798 Manual call point can immediate trigger a fire alarm by breaking the glass. • Connected to F-Bus. • Installed in the public area such as staircase‚ elevator lobby‚ etc. • Device address can be set via a DIP-switch. • Mounted on the wall and 1.3 to 1.6 meters above the ground. • Electronic part and housing are delivered separately. Operating voltage Operating temperature Relative humidity Quiescent current Alarm current Capacity of dry contact EMC Data sheet BDS121A -G 18...26 VDC -20... +55 °C ≤95 % (40 ± 2 °C) ≤0.5 mA ≤3.0 mA 24 VDC / 0.1 A 10 V/m A5Q00016799A Spare glass Spare glass for BDS121A manual call point. Delivery unit 50 pieces/pack © Siemens Ltd. Building Technologies Division S54421-B10-A1 13 Detectors & Peripherals Addressable Modules Type BDS132A Order No. Addressable Input Module A5Q00021150 The input module serves as an interface to transmit alarms or technical signals from other equipments to the fire alarm control unit. • Connected to the F-Bus‚ device address can be set with a DIP-switch. • Serves as interface for potential free signals from flow switches‚ pressure switches etc. to the fire alarm system. • The signal will be transmitted to the controller and trigger corresponding actions. • Connection faults will be automatically detected and displayed on the controller. Operating voltage Operating temperature Relative humidity Activation current Quiescent current Wiring capacity EOL Data sheet BDS221A 18... 26 VDC 0... +49 °C ≤93 % (32 ± 2 °C) ≤3.2 mA ≤1 mA 1.0...1.5 mm² EOL82 A5Q00021191A Addressable Output Module A5Q00021149 The output module is used to activate external equipment according to the function of the fire alarm unit. • Connected to the F-Bus‚ device address can be set with a DIP-switch. • Output can be configured as pulse or steady on with DIP-switch. • Connection is polarity free. • The input signal for feedback is a potential free contact. • It is not recommended to use this module for extinguishing control directly. • Faults will be automatically detected and displayed on the controller. Operating voltage Operating temperature Relative humidity Activation current Quiescent current Relay output Status LEDs Wiring capacity EOL Data sheet BDS152 * 18...26 VDC 0... +49 °C ≤95 % (32 ± 2 °C) ≤3.2 mA ≤1 mA 125 VAC / 0.6 A 24 VDC / 2 A Steady output - Steady ON Pulse Output - Flashing 1.0...1.5 mm² EOL82 A5Q00021192A Isolation Module A6C50000005 The isolation module is used to isolate a short circuit on the detection bus. The device will automatically recover to its normal status when the cause of the short circuit disapears. • The isolation module separates a short circuit on the F-Bus. • Parallel connection on the first place of each branch or stub is possible. • No device address is required. • When a single loop is used to connect devices mounted on several floors it is recommended to install one isolation module on each floor. • Up to 25 load factors can be mounted to an isolation module. • The connection is polarity free. • Faults will be automatically detected and displayed on the controller. Operating temperature Relative humidity Activation current Pass through voltage Wiring Capacity Data sheet BDS161 * -20... +50 °C ≤95 % (40 ± 2 °C) ≤0.5 mA ≤1 VDC 1.0... 1.5 mm² A5Q00016395A Collective Input Module A6C50000006 Collective input module can connect collective detectors to the F-Bus • Directly connected to the F-Bus‚ addresses are set with a DIP-switch • Up to 12 collective detectors can be connected to the module • An end of line element P6KE18CA has to be used. • Module transmits alarm‚ fault and danger level signal to the control unit • The same indications are displayed on the module. • Connection is polarity free. • Faults will be automatically detected and displayed on the control unit. Alarm voltage Fault voltage Normal voltage Alarm current Operating temperature Quiescent current Relative humidity Wiring Capacity Data sheet 3.7... 16.4 VDC 0... 3.7 VDC (short) 22.1 VDC (open) 16.4... 22.1 VDC <16 mA -10... +50 °C <4 mA ≤95 % (40 ± 2 °C) 1.0... 1.5 mm² A5Q00016397A * Optional non-UL products 14 © Siemens Ltd. Building Technologies Division Spare Parts & Upgrades Type BCE8001A Order No. Extension Card for BC8001A S54421-A2-A1 Extension card for BC8001A compact controller. This card contains the following interfaces: • A-Bus interface to add the network feature to the compact controller (networkable up to 16 controllers). • B-Bus interface to allow BC8001A to connect up to 3 B-Bus devices. • F-Bus interface for additional up to 127 points. Data sheet BCM8001A A5Q00016402A Line Card for BC8002A S54421-A3-A1 The BCM8001A is the line card connecting the BDS field devices to BC8002A. • Type can be automatic identified via auto mapping by controller. • Each BCM8001A can connect 4 lines; each line can connect up to 127 devices. • Overload protection is functioned when the line is overloaded. It recovers to normal status when the overload disappear. • B-Bus address set via Dip-switch on the board. Number of lines Max. address point per line Wiring Capacity Max. distance per line Short Protection Over voltage protection Connectable field devices Working voltage Quiescent current Data sheet BTM8014 * 4 127 1.0...1.5 mm2 700m Yes Yes BDS Series Regulated 18...26VDC Full load: 200.0mA No load: 110.0mA A6V10255858 Mimic Display Board S54421-F12-A1 • 60 outputs for LED activation • 1 dry contact output for buzzer • 2 inputs for “Buzzer silence” and “Lamp test” • Communication with controller via B-Bus (individual address) • External 24VDC power required • Input/output are not monitored • Max. length to controller 200m • Max. length to LED 500m • Max. 16 units of BTM8014 can be connected to BT8002A • Configured via BC80 configuration tool External input voltage Operating current (quiescent) Max. current Rated output per LED Max. current per LED Operating temperature Storage temperature Relative humidity Protocol Terminal block Data sheet 24 VDC±20% (Regulated) 110 mA 300 mA 10 mA 15 mA -3 ... +42 °C -20 ... +60 °C ≤95% (40± 2 °C) CAN 1.0...1.5 mm2 A6V10252688 * Optional non-UL products © Siemens Ltd. Building Technologies Division 15 Spare Parts & Upgrades Type TP80UL-UC * Order No. Printer for BC8001A S54421-C5-A1 A thermal sensitive printer can print out the event on the logger paper when event occurs. Only for BC8001A controller. Operating voltage Quiescent current Max. current TP80UL * 5VDC 15.0mA 300.0mA Printer for BC8002A S54421-C5-A2 Function is same as above, with additional 3U mounting kit. Only for BC8002A controller BCB8004 Power Supply for BC8001A Input voltage Charging current voltage Output AC fuse capacity Battery fuse capacity Operating temperature Storage temperature Relative humidity Over current protection Output chort protection Battery low protection BCB8005 120/240VAC@60/50Hz (+10%, -15%) ≤2.0A 6A@24VDC 5.0A 10.0A 0°C... +50°C -10°C... +50°C ≤95% (40±2°C) Output≥8.0*115% Output≤1.0Ω Voltage<20.0V Power Supply for BC8002A Input voltage Charging current voltage Output AC fuse capacity Battery fuse capacity Operating temperature Storage temperature Relative humidity Over current protection Output short protection Battery low protection BT8002A S54421-C4-A1 S54421-C4-A2 120/240VAC@60/50Hz (+10%, -15%) ≤2.0A 3A@5VDC/8A@24VDC 5.0A 10.0A 0°C... +50°C -10°C... +50°C ≤95% (40±2°C) Output≥8.0*115% Output≤1.0Ω Voltage<20.0V Operation Panel The BT8002A is the operation panel which used for display messages and handling events. • Can be connected with other control units via A-Bus. • Can be connected with interlocking panels, line cards, mimic display board via B-Bus. • Download/Upload port on the main board. • BT8002A operation panel has 10" LCD, indicators, keypads, numerical keys and buzzers. • Built-in FMS connection port, third party communication port. • Installation size 5U. BT8002A/en English version of BT8002A S54421-C6-A1 BT8002A/po Portuguese version of BT8002A S54421-C6-A2 BT8002A/tc Traditional Chinese version of BT8002A S54421-C6-A3 BT8002A/sp Spanish version of BT8002A S54421-C11-A2 * Optional non-UL products 16 © Siemens Ltd. Building Technologies Division Spare Parts & Upgrades Type BT8011 */BT8012 * Order No. BT8011 Interlocking Panel A6C50000032 BT8011 is an interlocking panel (with printer) which can activate the external equipment automatically or manually. It is usually installed with the controller together in the fire control center used for controlling very important equipment such as pumps, fans etc. Picture for BT8011 • 8 outputs, 16 inputs are equipped (of which 8 inputs are for confirmation, the other 8 inputs are reserved), each OC output capacity is 40mA@24VDC. • Output can be steady level or pulse. • Can be connected with control unit via B-Bus. • Indication of activation, confirmation and fault for each output . • Silence and indicator test keypad available. • Panel can be set to manual mode or automatic mode. • Dip-switch set the panel address, output mode, connection mode. • TP8000 printer built-in. Input voltage Quiescent current Alarm current Assembly height Operating temperature Storage temperature Relative humidity 22…29VDC 60.0mA 600.0mA 3U 0°C… +50°C -10°C… +50°C ≤95% (40±2°C) BT8012 Interlocking Panel (without printer) A6C50000033 BT8012 is an interlocking panel which can activate the external equipment automatically or manually. It is usually installed with the controller together in the fire control center used for controlling very important equipments such as pumps, fans etc. • 16 outputs, 24 inputs are equipped (of which 16 inputs are for confirmation, the other 8 inputs are reserved), each OC output capacity is 40mA@24VDC. • Output can be steady level or pulse. • Can be connected with control unit via B-Bus. • Indication of activation, confirmation and fault for each output. • Silence and indicator test keypad available. • Panel can be set to manual mode or automatic mode. • Dip-switch set the panel address, output mode, connection mode. Input voltage Quiescent current Alarm current Assembly height Operating temperature Storage temperature Relative humidity 22…29VDC 100.0mA 820.0mA 3U 0°C… +50°C -10°C… +50°C ≤95% (40±2°C) * Optional non-UL products © Siemens Ltd. Building Technologies Division 17 Type Index Type Description Order No. Page BC8001A Compact Control Unit with 1 F-Bus line A5Q00016659 9 BC8001AE Compact Control Unit with 2 F-Bus lines A5Q00021716 9 BC8002A-1/en English version of BC8002A-1 S54421-C7-A1 10 BC8002A-1/po Portuguese version of BC8002A-1 S54421-C5-A6 10 BC8002A-1/tc Traditional Chinese version of BC8002A-1 S54421-C5-A3 10 BC8002A-1/sp Spanish version of BC8002A-1 S54421-C7-A2 10 BC8002A-2/en English version of BC8002A-2 S54421-C8-A1 10 BC8002A-2/po Portuguese version of BC8002A-2 S54421-C5-A7 10 BC8002A-2/tc Traditional Chinese version of BC8002A-2 S54421-C5-A4 10 BC8002A-2/sp Spanish version of BC8002A-2 S54421-C8-A2 10 BC8002A-3/en English version of BC8002A-3 S54421-C9-A1 10 BC8002A-3/po Portuguese version of BC8002A-3 S54421-C5-A8 10 BC8002A-3/tc Traditional Chinese version of BC8002A-3 S54421-C5-A5 10 BC8002A-3/sp Spanish version of BC8002A-3 S54421-C9-A2 10 BDS031A Addressable Heat Detector A5Q00016746 11 BDS051A Addressable Optical Smoke Detector A5Q00016747 11 BDS000A Addressable Detector Base A5Q00016958 11 HI520 * Collective Heat Detector A6C50000009 12 OP520 * Collective Optical Smoke Detector A6C50000010 12 SO520 * Collective Detector Base A6C50000011 12 BDS121A Addressable Manual Call Point A5Q00016798 13 BDS121A-G Spare glass S54421-B10-A1 13 BDS132A Addressable Input Module A5Q00021150 14 BDS221A Addressable Output Module A5Q00021149 14 BDS152 * BDS152 Isolation Module A6C50000005 14 BDS161 * BDS161 Collective Input Module A6C50000006 14 BCE8001A Extension Card for BC8001A S54421-A2-A1 15 BCM8001A Line Card for BC8002A S54421-A3-A1 15 BTM8014 * Mimic Display Board S54421-F12-A1 15 TP80UL-UC * Printer for BC8001A S54421-C5-A1 16 TP80UL * Printer for BC8002A S54421-C5-A2 16 BCB8004 Power Supply for BC8001A S54421-C4-A1 16 BCB8005 Power Supply for BC8002A S54421-C4-A2 16 BT8002A/en English version of BT8002A S54421-C6-A1 16 BT8002A/po Portuguese version of BT8002A S54421-C6-A2 16 BT8002A/tc Traditional Chinese version of BT8002A S54421-C6-A3 16 BT8002A/sp Spanish version of BT8002A S54421-C11-A2 16 BT8011 * Interlocking Panel A6C50000032 17 BT8012 * Interlocking Panel (without printer) A6C50000033 17 * Optional non-UL products 18 © Siemens Ltd. Building Technologies Division BC80A Fire Detection System Product Catalogue - Appendix Answers for infrastructure. 19 Appendix Index System Installation Guideline 21 System Design Guideline 24 1.1 A-BUS 24 1.2 BC80A System Connection 24 1.3 Single Controller 24 1.4 BC8002A NAC & I/O on mainboard 25 1.5 BC8001A Wiring Diagram 26 1.6 BC8002A System Wiring Diagram 27 1.7 BC8001A System Wiring Diagram 27 2.1 B-BUS 28 2.2 BTM8014 Mimic Display Board Wiring Diagram 28 2.3 BT8011/BT8012 Wiring Diagram 28 3.1 F-BUS 29 3.2 BDS152 Wiring Diagram 29 3.3 BDS161 Wiring Diagram 30 Installation Instruction 20 31 4.1 BDS000A Addressable Detector Base 31 4.2 BDS121A Addressable Manual Call Point 32 4.3 BDS132A Addressable Input Module 33 4.4 BDS221A Addressable Output Module 34 BC80A System Installation Guidelines In this section, we illustrate best practice for installation of fire detection equipment. While not all possible cases may be covered, these are intended to provide guidelines. Local regulations may be more detailed and must always be observed. Please contact your local Siemens sales organization for more detailed information and documentation. Detectors – detectors should be positioned* ■ at least 0.5 m from the wall ■ max. 12 m from the previous detector Manual call points – manual call points should be positioned* ■ in a clearly visible location ■ 1.5 m from floor level Fire control panels – mounting the fire control panel* Keep a minimum distance to objects which could obscure the panel or the view to it Detector positioning near elevators* 21 BC80A System Installation Guidelines Detector positioning near fresh air supply* Use a support to install a detector at ceiling height* Place the detector at the highest point in the room* 22 BC80A System Installation Guidelines Ensure the correct distance to ceiling obstacles* Position the detector within the top 10% of a space* Ensure a minimum distance to objects which could obstruct the view to a manual call point* Manual call points should not be obscured by an open door* * or observe local regulations 23 BC80A System Design Guideline 1.1 A-BUS A-BUS: communication between controllers (CAN-BUS communication). Twisted-pair wiring is required, the maximum length is 700m. 1.2 BC80A System Connection ■ BC80A system can allow to connect max. 8 BC8002A and 8 BC8001A controllers within the same A-Bus with a total of 16 controllers in peer to peer configuration. Each controller can be configured to monitor and control all connected field devices within the entire network. ■ Interlocking controls can be programmed within the same controller or across other controllers. ■ A-Bus network will need to install End-of-line resistor (120Ω) at both ends (EOL setting via dip-switch or jumper) 1.3 Single Controller ■ 2 NAC circuits, 2 inputs, 2 outputs ■ Optional: BT8011 interlocking panel (8 output ports + printer) ■ Optional: BT8012 interlocking panel (16 output ports) 24 BC80A System Design Guideline 1.4 BC8002A NAC & I/O on mainboard 25 BC80A System Design Guideline 1.5 BC8001A Wiring Diagram 26 BC80A System Design Guideline 1.6 BC8002A System Wiring Diagram Address of BC8002A, BCM8001A and field devices should be set via dip-switch, and must be the same as the address assigned in the programming tool. ■ Set the addresses of field devices via Dip-switch on the field devices ■ The address set by Dip-switch shall be equivalent to the address set by the configuration tool ■ BDS152 does not need to set address 1.7 BC8001A System Wiring Diagram ■ Set the addresses of field devices via Dip-switch on the field devices ■ The address set by Dip-switch shall be equivalent to the address set by the configuration tool ■ BDS152 does not need to set address ■ Without extension card, the default address of BC8001A is 1 and shall not be change; With extension card, the address of BC8001A should be set via the dip-switch on the extension card, and must be the same as the address assigned in the programming tool. 27 BC80A System Design Guideline 2.1 B-BUS B-BUS: communication between line cards, interlocking panels, mimic display boards and controllers (CAN-BUS communication). Twisted-pair wiring is required, the maximum length is 200m. 2.2 BTM8014 Mimic Display Board Wiring Diagram ■ 60 outputs for LED activation ■ Communication with controller via B-Bus (individual address) ■ 1 dry contact output for buzzer ■ External 24VDC power required ■ 2 inputs for “Buzzer silence” and “Lamp test” ■ Input/output are not monitored Figure 1 Wiring diagram Figure 2 Wiring diagram 2.3 BT8011/BT8012 Wiring Diagram ■ BT8011 has 8 output ports, output capacity is 24VDC/40mA per line; It also has 16 contact input ports, 8 of them are used for input confirmation signals from activated devices, the other 8 contacts are reserved. BT8011 is equipped with printer and needed to be used with BC80 control unit together. ■ BT8012 has 16 output ports, output capacity is 24VDC/40mA per line; It also has 24 contact input ports, 16 of them are used for ■ Output signal mode: pulse signals or level signals ■ Can be set to manual mode or automatic mode input confirmation signals from activated devices and the other 8 contacts are reserved. Figure 1 BT8011 Interlocking Panel wiring diagram 28 BC80A System Design Guideline Figure 2 BT8012 Interlocking Panel wiring diagram 3.1 F-BUS F-BUS: communication between line card and field devices. Twisted-pair wiring is recommended and the wiring length should less than 700m. 3.2 BDS152 Wiring Diagram ■ To be used in the way of parallel connection at the starting point of every branch. ■ This is a non-addressable component for installation on site. ■ Each BDS152 isolator can connect with up to 25 load factors. ■ The control unit automatically detects any possible fault. ■ The input connectors”P0” should connect to “P” port of F-Bus of control unit and the input connector “S0” of BDS152 should connect ■ When connected with field devices, the “P” and “S” output lines of BDS152 are polarity free. to “S” port of F-Bus of control unit. 29 BC80A System Design Guideline 3.3 BDS161 Wiring Diagram ■ Each F-Bus can be connected with maximum 10 BDS161 modules. ■ Each BDS161 can be connected with maximum 12 collective detectors. ■ To set the address of BDS161 modules with DIP-switches. ■ To connect “P” and “S” connectors of the module to F-Bus of control units (Polarity free). ■ Each BDS161 can be connected with max. one linear smoke detector. ■ Max.10 Detector-Ex can be connected on BDS161 via DC1192*, SB3*. Detector-Ex is including DO1101-Ex*, DT1101-Ex*, DT1102-Ex*, DF1101-Ex*. ■ Consult local Siemens for ordering information 30 BC80A Installation Instruction 4.1 BDS000A Addressable Detector Base Installation Detector placement should follow the drawings provided or approved by Siemens Building Technologies or by its authorized distributors. This is extremely important! The detector placements shown on these drawings were chosen after a careful evaluation of all facets of the protected area, such as air currents, temperature, humidity, pressure, the nature of the fire load and type of ceiling etc. When drawings are not available, refer to Detector Installation section of detector Installation Instructions or refer to relevant items of NFPA 72. Wiring 1. Route wires through the centre hole of the base and mount base to ceiling (the distance between two installation holes is 62mm). When alarm LED viewing is critical, position the LED positioning symbol in the base in the intended direction. 2. Make connections directly to the base terminals. Refer to Figure 2 for details. Figure 1 Mounting the BDS000A Note • Do not install detector until all construction is completed. • It is recommended wiring with twisted-pair cable from base to base, the wiring requirement is 1.0 to 1.5mm2. P To BC80A compatible control unit Detector base Model BDS000A 1 2 3 4 S P To next base Do not use an end of line device S Figure 2 Wiring diagram for BDS000A 31 BC80A Installation Instruction 4.2 BDS121A Addressable Manual Call Point Installation 1. Fix the housing at a height of 1.3 to 1.6m on an flat surface. 2. Pull the cables through the inlet opening(s) and into the housing. 3. With surface mounting, use the screwed cable glands ( max. M20*1.5 ) 4. Close the housing with the cover. Wiring: 1. Open cover with key. 2. Connect the feed line to the terminals on the manual signalling box according to figure 1/2. Figure 1 Terminal connection 3. Consider the feed line when insert the electronic unit. 4. Place the electronic unit into the housing with the inscription “TOP” pointing upward (terminals at the right) until the locking device engages (see figure 3). When you want to take out the electronic unit, thumbs press the top locking device and pull it out. 5. Close the housing with the cover. Locking device Locking device hole P Line S Line P Line S Line Locking device Figure 2 Wire routing diagram Figure 3 Electronic unit Installation Note • The electronic unit and the housing are delivered separately. • Do not install electronic unit until all installation is completed. • It is recommended wiring with twisted-pair cable. The wiring requirement is 1.0 to 1.5mm2. 32 Locking device hole BC80A Installation Instruction 4.3 BDS132A Addressable Input Module Installation Pre-Installation: Set address for each BDS132A module using the Dip-switch (binary, the first 1-7 digits are available and the last digit is reserved) located on the module. Each of these addresses must be the same as the addresses assigned in the project file. The BDS132A input module should be installed in the following way: 1. Drill 2 holes (distance is 60mm) on the wall. See figure 1. 2. Fix the module housing on wall with 2 M3 screws. 3. Connect “P” and “S” terminals to detection bus. 4. Connect the normal open contacts of field devices to terminals “D” and “G” and bridge the terminals at the device end with end of line (EOL82). See figure 2. A listed gang box (4×4×2 inch) must be used for mounting. Note • It is recommended wiring with twisted-pair cable from module to module. The wiring requirement is 1.0 to 1.5mm2. Figure 1 Installation diagram Notes 1. Input is supervised. 2. Max. distance 200m (the wring requirement is 1.0mm2) from BDS132A to input contact. 3. All circuits are power limited. Figure 2 Wring diagram 33 BC80A Installation Instruction 4.4 BDS221A Addressable Output Module Pre-Installation 1. Set address for each BDS221A module using the Dip-switch (binary, the first 1-7 digits are available) located on the module. Each of these addresses must be the same as the addresses assigned in the project file. 2. Set deliver signal type using the 8th digit of the Dip-switch: “on” – deliver continuous level signal; “off”- deliver pulse signal. The BDS221A output module should be installed in the following way: 1. Drill 2 holes (distance is 60mm) into the wall. See figure 1. 2. Fix the module housing on wall with 2 M3 screws. 3. Connect “P” and “S” terminals to detection bus. 4. In the case of voltage signal output, connect “CO-NO” or “CO-NC” terminals to the controlled equipment. Connect “G” and “D” with dry contacts of controlled equipment as feedback monitoring if it is necessary. See figure 2. A listed gang box ( 4×4×2 inch ) must be used for mounting. Note • It is recommended wiring with twisted-pair cable from module to module, the wiring requirement is 1.0 to 1.5mm2. Figure 1 Installation diagram Notes 1. Input is supervised. 2. Max. distance 200m (the wring requirement is 1.0mm2) from BDS221A to input contact. 3. All circuits are power limited. The relay contacts must be connected to a power limited source. 4. Relay Output: 2A, 30VDC. Figure 2 Wring diagram 34 35 Siemens Switzerland Ltd Industry Sector Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel + 41 41 724 24 24 The information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. The required features should therefore be specified in each individual case at the time of closing the contract. © Siemens Switzerland Ltd 36