Cable type DLO/RHH/RHW

advertisement
Cable type DLO/RHH/RHW-2/RW90
Flexible 90°C / 2000V Power Cable
Cable type DLO is a flexible single conductor power cable
with an ozone, sunlight, oil, grease, weather, chemical
and abrasion resistant jacket. Meets MSHA flame test
requirements.
c
Designed fo ruses requiring a flexible heavy duty power
cables. For portable or fixed installations, shipyards and
cranes, motors, generators, portable or fixed.
Cable type DLO:
Flexible stranded, tinned annealed copper conductors; ethylene proplyene thermosetting compound type EP
insulation; tape separator; heavy duty black thermosetting CPE rubber jacket meeting ICEA S-68-516.
Sizes 1 AWG and smaller: DLO
(UL) TYPE RHW–2 (SIZE) 2KV VW–1 C(UL) TYPE RW90 EP 1000V (CSA) 205591 R90 EP -40°C
FT1 1KV TYPE DLO 2KV 90°C P-7K-268080-01-MSHA
Sizes 1/0 AWG and larger: DLO CT
(UL) TYPE RHW–2 (SIZE) 2KV LS FT–4 VW–1 FOR CT USE C(UL) TYPE RW90 EP 1000V (CSA)
205591 R90 EP -40°C FT1 1KV TYPE DLO 2KV 90°C P-7K-268080-01-MSHA
* MSHA, “VW-1”, Sun Res”, “For CT Use” for sizes 1/0 AWG and larger
Technical Data:
Temperature:
90oC
Nominal Voltage:
2000V
Conductor Stranding:
Fine wire
Part
Number
LMDLO14
LMDLO12
LMDLO10
LMDLO8
LMDLO6
LMDLO4
LMDLO2
LMDLO1
LMDLO1/0
LMDLO2/0
LMDLO3/0
LMDLO4/0
LMDLO262
LMDLO313
LMDLO373
LMDLO444
LMDLO535
LMDLO646
LMDLO777
LMDLO929
LMDLO1111
AWG/ MCM
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
2 AWG
1 AWG
1/0 AWG
2/0 AWG
3/0 AWG
4/0 AWG/
262.6 KCMIL
313.1 KCMIL
373.7 KCMIL
444.4 KCMIL
535.3 KCMIL
646.4 KCMIL
777.7 KCMIL
929.2 KCMIL
1111 KCMIL
Approvals:
Copper
Stranding
19/27
19/25
27/24
37/24
61/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2300/24
2750/24
Nominal Insulation
Thickness
inches
mm
.045
.045
.045
.060
.060
.060
.060
.080
.080
.080
.080
.080
.095
.095
.095
.095
.110
.110
.110
.120
.125
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
2.03
2.41
2.41
2.41
2.41
2.79
2.79
2.79
3.05
3.18
RW90 c(UL)
R90 CSA
Type DLO-CT 2000V
RHW-2 (Conductor Size)
2 Kv (UL) FT-4, VW-1
For CT use c(UL) Type
RW90-1 Kv
90oC dry and wet
MSHA
Nominal Jacket
Thickness
inches
mm
.030
.030
.030
.030
.030
.030
.030
.045
.045
.045
.045
.045
.065
.065
.065
.065
.065
.065
.065
.065
.095
0.76
0.76
0.76
0.76
0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.14
1.65
1.65
1.65
1.65
1.65
1.65
1.65
1.65
2.41
Nominal Outer
Diameter
inches
mm
.236
.256
.290
.333
.403
.461
.510
.650
.700
.740
.815
.870
.990
1.055
1.125
1.205
1.305
1.410
1.500
1.610
1.800
6
7
7
8
10
12
13
17
18
19
21
22
25
27
29
31
33
36
38
41
46
Approx.
Weight
lbs/mft
25
46
67
95
134
192
248
428
480
558
742
872
1068
1258
1462
1726
2047
2416
2881
3455
4077
01800 - 024 -5277 • www.lappmexico.com
The products and specifications set forth in this brochure are subject to change without notice and LAPP Group disclaims any and all liability for such variations. LAPP Group further disclaims any and all liability for typographical, printing,
or production errors or changes affecting the products and/or the specifications.
© 2006 LAPP Group, Inc.
DLO Cable 09/09
Download