Cable type DLO/RHH/RHW-2/RW90 Flexible 90°C / 2000V Power Cable Cable type DLO is a flexible single conductor power cable with an ozone, sunlight, oil, grease, weather, chemical and abrasion resistant jacket. Meets MSHA flame test requirements. c Designed fo ruses requiring a flexible heavy duty power cables. For portable or fixed installations, shipyards and cranes, motors, generators, portable or fixed. Cable type DLO: Flexible stranded, tinned annealed copper conductors; ethylene proplyene thermosetting compound type EP insulation; tape separator; heavy duty black thermosetting CPE rubber jacket meeting ICEA S-68-516. Sizes 1 AWG and smaller: DLO (UL) TYPE RHW–2 (SIZE) 2KV VW–1 C(UL) TYPE RW90 EP 1000V (CSA) 205591 R90 EP -40°C FT1 1KV TYPE DLO 2KV 90°C P-7K-268080-01-MSHA Sizes 1/0 AWG and larger: DLO CT (UL) TYPE RHW–2 (SIZE) 2KV LS FT–4 VW–1 FOR CT USE C(UL) TYPE RW90 EP 1000V (CSA) 205591 R90 EP -40°C FT1 1KV TYPE DLO 2KV 90°C P-7K-268080-01-MSHA * MSHA, “VW-1”, Sun Res”, “For CT Use” for sizes 1/0 AWG and larger Technical Data: Temperature: 90oC Nominal Voltage: 2000V Conductor Stranding: Fine wire Part Number LMDLO14 LMDLO12 LMDLO10 LMDLO8 LMDLO6 LMDLO4 LMDLO2 LMDLO1 LMDLO1/0 LMDLO2/0 LMDLO3/0 LMDLO4/0 LMDLO262 LMDLO313 LMDLO373 LMDLO444 LMDLO535 LMDLO646 LMDLO777 LMDLO929 LMDLO1111 AWG/ MCM 14 AWG 12 AWG 10 AWG 8 AWG 6 AWG 4 AWG 2 AWG 1 AWG 1/0 AWG 2/0 AWG 3/0 AWG 4/0 AWG/ 262.6 KCMIL 313.1 KCMIL 373.7 KCMIL 444.4 KCMIL 535.3 KCMIL 646.4 KCMIL 777.7 KCMIL 929.2 KCMIL 1111 KCMIL Approvals: Copper Stranding 19/27 19/25 27/24 37/24 61/24 105/24 150/24 225/24 275/24 325/24 450/24 550/24 650/24 775/24 925/24 1100/24 1325/24 1600/24 1925/24 2300/24 2750/24 Nominal Insulation Thickness inches mm .045 .045 .045 .060 .060 .060 .060 .080 .080 .080 .080 .080 .095 .095 .095 .095 .110 .110 .110 .120 .125 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 2.03 2.41 2.41 2.41 2.41 2.79 2.79 2.79 3.05 3.18 RW90 c(UL) R90 CSA Type DLO-CT 2000V RHW-2 (Conductor Size) 2 Kv (UL) FT-4, VW-1 For CT use c(UL) Type RW90-1 Kv 90oC dry and wet MSHA Nominal Jacket Thickness inches mm .030 .030 .030 .030 .030 .030 .030 .045 .045 .045 .045 .045 .065 .065 .065 .065 .065 .065 .065 .065 .095 0.76 0.76 0.76 0.76 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.65 1.65 1.65 1.65 1.65 1.65 1.65 1.65 2.41 Nominal Outer Diameter inches mm .236 .256 .290 .333 .403 .461 .510 .650 .700 .740 .815 .870 .990 1.055 1.125 1.205 1.305 1.410 1.500 1.610 1.800 6 7 7 8 10 12 13 17 18 19 21 22 25 27 29 31 33 36 38 41 46 Approx. Weight lbs/mft 25 46 67 95 134 192 248 428 480 558 742 872 1068 1258 1462 1726 2047 2416 2881 3455 4077 01800 - 024 -5277 • www.lappmexico.com The products and specifications set forth in this brochure are subject to change without notice and LAPP Group disclaims any and all liability for such variations. LAPP Group further disclaims any and all liability for typographical, printing, or production errors or changes affecting the products and/or the specifications. © 2006 LAPP Group, Inc. DLO Cable 09/09