codes and standards • UL listed to Standard 924 • NFPA 101 (Life Safety Code) • IBC, NFPA 70 (National Electric Code) and OSHA Standards California Energy Commission • UL listed for damp location as an optional feature construction • Available in matte black housing with brushed aluminum face; white housing with a brushed aluminum face. • All black, white or aluminum housing and face. • Black and white finishes are epoxy based powder coat paint. • Cast aluminum with perfectly stenciled 6” EXIT letters backed with durable green or red panel. • NFPA compliant field selectable chevrons. installation • A universal, shallow canopy is provided with each exit for ceiling and end mounting. • Provisions are available via universal knockouts for direct mounting to recessed junction box. • Back wall mount units require no conopy on standard or emergency exits because battery and electronics are inside housing. electronics • AC Only: 120/277 VAC dual voltage input with surge protection is standard on all models. -40°F (-40°C) to 113°F (45°C). • Emergency Operation 120/277 VAC input, surge protection, brownout, AC lockout and low voltage disconnect features are standard. 32°F (0°C) to 104°C (40°C). CE-11400 • Wattage – AC Only Operation - Input Power Requirements Red – 3.8 Watts (120 VAC), PF = 0.96 – 3.8 Watts (277 VAC), PF = 0.91 Green – 4.0 Watts (120 VAC), PF = 0.95 – 4.0 Watts (277 VAC), PF = 0.90 Self-Powered - Input Power Requirements Input Power Requirements Red – 4.7 Watts (120 VAC), PF = 0.95 – 4.8 Watts (277 VAC), PF = 0.97 Green – 4.7 Watts (120 VAC), PF = 0.95 – 4.7 Watts (277 VAC), PF = 0.99 • The electronics diagnostic/charging platform with self-testing mode automatically runs a one-minute self-test every 30 days and a 30 minute on the sixth and twelfth month. A one minute or 90 minute test may be initiated via the push to test switch on the unit or by activating the appropriate test command on the optional SRT remote tester. rev. 10, Commercial Exit Signs 55 Line Die Cast Aluminum LED Traditional LED • Exit face illumination is provided by a special high intensity indirect red or green LED strip. Letter brightness and illumination uniformity exceed UL requirements. battery • Maintenance free, sealed nickel cadmium battery provides 90 minutes of emergency illumination. Specifier’s Reference Project Type warranty Model No. • Five year warranty from date of purchase. Comments Green Product Choice: ER55LDT212/27WRFIF Accessories No. of Faces 1 – Single Face 2 – Double Face Family 55LA – LED (AC Only) ER55LDT – Emergency LED, Nicad battery, self-diagnostic/ self-test Housing Finish BLANK – Matte Black with brushed Alum. face A – Aluminum B – Black W – White WB – White with brushed Alum. face Input Voltage 12/27 – Dual Voltage (120/277v) Footnotes Used only on Emergency Exits. The LED lamps will flash and/or activate the buzzer when normal power fails (Emergency Mode) 2 55LA version: The LED Lamps will flash when activated if external EM backup is present. ER55LDT version: The LED lamps will flash when activated by internal battery upon failure of normal power. 3 55LA Series only. 4­ Requires longer 13.5" x 8.5" x 2.5" housing. 5­ Some options may impact UL listing when combined with other options. (Consult factory.) 1 © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. CE-11400 03/13 Options 5 Letter Color R – Red G – Green TP – Tamperproof Screws DR – Damp Location Rating F – Flashing in Emergency Mode1 B – Buzzer in Emergency Mode1 FB – Flashing/Buzzer in Emergency Mode1 FIF – Fire Alarm Interface with Flashing2 DC – 12-48VDC External Back-up (AC only)3 VL – Vandal Resistant Lens 2C12 – Two Circuit (120v) AC only3 2C27 – Two Circuit (277v) AC only3 SW – Special Wording4 EX – Special Input Transformer (specify voltage and frequency) TA – Audible Self-diagnostics PCS1 – Polycarbonate Vandal Shield WG4 – Wire Guard for wall mounting WGI0 – Wire Guard for end mounting 55LPKIT12W – Pendant Assembly, 12" white 55LPKIT12B – Pendant Assembly, 12" black T15TPTOOL – Tamper Proof Screwdriver SRT – Self testing red remote tester Note: For (8" Letters) New York City die cast aluminum exit signs, refer to specification sheet number CN-26300. CE-11400 dimensions 55 Line Die Cast Aluminum LED Traditional rev. 10, Wall Mount 8-1/8" (210mm) End Mount EXIT 13-1/4" (337mm) 4-3/4" (121mm) 4-5/8" (118mm) EXIT 14" (356mm) 2-3/8" (606mm) 2-3/8" (60mm) Recessed Mount 4-5/8" (118mm) 8-7/8" (226mm) Front EXIT 13-1/4" (337mm) 2-3/8" (60mm) Back System Reset: Two presses of "SILENCE ALARM" button followed by two presses of "CANCEL" button. Interpretation of Flashing Indicator lights on Equipment: Green LED Indicator: • Steady On - Normal • Slow Flash - Battery Charging • Fast Flash - Unit is self-testing Red LED Indicator: • Single Flash - Battery Fault • Double Flash - Lamp Failure • Triple Flash - Charger Fault • Quad Flash - Emergency Transfer Failure Red and Green LED indicators flashing together: • Slow Flashing - Low Line Voltage • Fast Flashing - High Line Voltage Unit Equipment Lamp Calibration Press "Silence Alarm" twice followed by one press of "Cancel" and one press of "Silence Alarm" For Service Call (910)259-1000 3.38" (86mm) 2.13" (54mm) © 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008 CE-11400 03/13 www.philips.com/luminaires www.philips.com/luminaires