DC Current transducer DF-C10 IPN = 10 .. 500 mA For the electronic mesurement of low DC currents, with galvanic isolation between the primary (High power) and the secondary circuits (Electronic circuit). Provisional Electrical data Primary Nominal Current Analogue Output Signal I PN (mA.t.) VOUT (V) 10 ± 10 ± 10 ± 10 ± 10 ± 10 ± 10 20 50 100 300 500 Type Features DF 0.01 C10 • DC Measurement • Low current transducer • Panel mounting • Bipolar voltage supply • Extended measuring range. DF 0.02 C10 DF 0.05 C10 DF 0.1 C10 DF 0.3 C10 DF 0.5 C10 I OC Overload capacity 200 VC Supply voltage ± 12 .. 15 IC Current consumption (max) 20 RL Load resistance Limitation of voltage output ≥2 10.5 At mA kΩ V DC Accuracy - Dynamic performance data X Accuracy of reading @ ± 12V, TA=25°C ±4 VOE Linearity error of IPN Electrical offset voltage @ TA=25°C ± 0.8 ±1 VOT Thermal drift of VOE ε L DF 0.1 C10 % % % of IPN ±4 mV/k ± 30 mV/k ± 20 mV/k ± 50 mV/k TCεG Thermal drift of the gain tr Response time @ 90% of IPN < 140 ms f Frequency bandwith DC Hz DF 0.1 C10 Advantages V DC General data • Large aperture • Good performances in harsh EMC environment • High isolation between primary and secondary circuits • Easy to mount • Bipolar • No insertion losses. Applications • DC leakage current measurement • Differential current measurement in DC applications • Low DC current measurement. Application domain TA Ambient operating temperature 0 ..+ 70 °C TS Ambient storage temperature -25 ..+ 85 °C m Mass 140 Protection type IP20 UL94 classification V0 • Industrial. g Options on request • DIN mounting. Notes : Installation and maintenance should be done with power supply disconnected. The operator must have accreditation to install this material. The users must guarantee protection against electrical shock when using this device. 050112/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components page 1/3 www .lem.com DC Current transducer DF-C10 Isolation characteristics Vd R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 5 kV Ve R.m.s. voltage for partial discharge extinction @ 10pC 1.5 kV VW Peak Impulse withstand voltage 1.2/50 6.1 kV dCp dCl CTI Creepage distance Clearance distance Comparative Tracking Index (Group I) Min 5.5 5.5 600 mm mm V Min Application examples According to EN 50178 and CEI 61010-1 standards and following conditions : • Over voltage category CAT III • Pollution degree PD2 • Non-uniform field If isolated cable is used for the primary circuit , the voltage category could be improved with the following table : Cable isolation (primary) HAR 05 HAR 07 Category 600 V CAT III 1000 V CAT III Safety This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected. 0412212 050112/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components page 2/3 www .lem.com Dimensions DF-C10 (unit : mm, 1mm = 0.0394 inch) Secondary terminals Terminal 1 : Supply voltage + 12 .. + 15 VDC 38 Terminal 2 : Supply voltage - 12 .. - 15 VDC Terminal 3 : Voltage output Vs Terminal 4 : 0V Mechanical characteristics • General tolerance ± 1 mm • Primary aperture ∅ 25 mm • Secondary connection Finger safe terminals • Panel mounting Distance between holes Output Voltage / Primary Current VOUT (V) 2 holes ∅ 4.2 mm 38 mm x 55 mm 10.5V DC 10V DC Î P max I PN I PN Î P max IP(A) - 10V DC - 10.5V DC Remark • Temperature of the primary conductor should not exceed 60°C. 050112/1 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. LEM Components page 3/3 www .lem.com