DC Current transducer DF-C10 I = 10 .. 500 mA Provisional

advertisement
DC Current transducer DF-C10
IPN = 10 .. 500 mA
For the electronic mesurement of low DC currents, with galvanic
isolation between the primary (High power) and the secondary circuits
(Electronic circuit).
Provisional
Electrical data
Primary Nominal Current
Analogue Output Signal
I PN (mA.t.)
VOUT (V)
10
± 10
± 10
± 10
± 10
± 10
± 10
20
50
100
300
500
Type
Features
DF 0.01 C10
• DC Measurement
• Low current transducer
• Panel mounting
• Bipolar voltage supply
• Extended measuring range.
DF 0.02 C10
DF 0.05 C10
DF 0.1 C10
DF 0.3 C10
DF 0.5 C10
I OC
Overload capacity
200
VC
Supply voltage
± 12 .. 15
IC
Current consumption (max)
20
RL
Load resistance
Limitation of voltage output
≥2
10.5
At
mA
kΩ
V DC
Accuracy - Dynamic performance data
X
Accuracy of reading @ ± 12V, TA=25°C
±4
VOE
Linearity error of IPN
Electrical offset voltage @ TA=25°C
± 0.8
±1
VOT
Thermal drift of VOE
ε
L
DF 0.1 C10
%
%
% of IPN
±4
mV/k
± 30
mV/k
± 20
mV/k
± 50
mV/k
TCεG
Thermal drift of the gain
tr
Response time @ 90% of IPN
< 140
ms
f
Frequency bandwith
DC
Hz
DF 0.1 C10
Advantages
V DC
General data
• Large aperture
• Good performances in harsh
EMC environment
• High isolation between primary
and secondary circuits
• Easy to mount
• Bipolar
• No insertion losses.
Applications
• DC leakage current
measurement
• Differential current
measurement in DC applications
• Low DC current measurement.
Application domain
TA
Ambient operating temperature
0 ..+ 70
°C
TS
Ambient storage temperature
-25 ..+ 85
°C
m
Mass
140
Protection type
IP20
UL94 classification
V0
• Industrial.
g
Options on request
• DIN mounting.
Notes : Installation and maintenance should be done with power supply disconnected.
The operator must have accreditation to install this material.
The users must guarantee protection against electrical shock when using this
device.
050112/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
page 1/3
www .lem.com
DC Current transducer DF-C10
Isolation characteristics
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
5
kV
Ve
R.m.s. voltage for partial discharge extinction @ 10pC
1.5
kV
VW
Peak Impulse withstand voltage 1.2/50
6.1
kV
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group I)
Min
5.5
5.5
600
mm
mm
V
Min
Application examples
According to EN 50178 and CEI 61010-1 standards and following conditions :
• Over voltage category CAT III
• Pollution degree PD2
• Non-uniform field
If isolated cable is used for the primary circuit , the voltage category could be improved with the
following table :
Cable isolation (primary)
HAR 05
HAR 07
Category
600 V CAT III
1000 V CAT III
Safety
This transducer must be used in electric/electronic equipment
with respect to applicable standards and safety requirements in
accordance with the following manufacturer's operating
instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can
carry hazardous voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious
damage.
This transducer is a built-in device, whose conducting parts
must be inaccessible after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
0412212
050112/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Components
page 2/3
www .lem.com
Dimensions
DF-C10
(unit : mm, 1mm = 0.0394 inch)
Secondary terminals
Terminal 1 : Supply voltage + 12 .. + 15 VDC
38
Terminal 2 : Supply voltage - 12 .. - 15 VDC
Terminal 3 : Voltage output Vs
Terminal 4 : 0V
Mechanical characteristics
• General tolerance
± 1 mm
• Primary aperture
∅ 25 mm
• Secondary connection
Finger safe terminals
• Panel mounting
Distance between holes
Output Voltage / Primary Current
VOUT (V)
2 holes ∅ 4.2 mm
38 mm x 55 mm
10.5V DC
10V DC
Î P max I PN
I PN Î P max
IP(A)
- 10V DC
- 10.5V DC
Remark
• Temperature of the primary conductor should not
exceed 60°C.
050112/1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.