Datasheet

advertisement
N
AUTOMOTIVE CURRENT TRANSDUCER
CAB 300-C/SP2
The CAB family is for battery monitoring applications
where high accuracy and very low offset are required.
Features
Transducer using Fluxgate technology
E
Principle of Fluxgate transducers
Introduction
A low-frequency fluxgate transducer is made of a wound core
which saturates under low induction.
A current chopper switches the winding’s current to saturate the
magnetic core alternatively at ± B max with a fixed frequency.
M
Fluxgate transducers use the change of the saturation’s
point symmetry to measure the primary current.
●● Zero offset
●● Unlimited over-current capability
Due to the principle of switching the current, all offsets (electric
and magnetic) are cancelled.
●● Panel mounting
●● Unipolar + 12 V battery power supply
●● TA = - 40°C .. + 105°C
●● Accuracy (over temperature)
I
- εG= Sensitivity error < 0.5 %
- εL= Linarity error < 0.1 %
●● Output signal:
Current
chopper
- CAN.C (500 kbps)
Signal
aquisition
and
processing
digital
Output
C
●● Optional internal digital low-pass frequency filter.
Advantages
●● No offset error
●● High accuracy
E
●● Low linearity error
●● Full galvanic isolation.
Automotive applications
●● Hybrid and electric vehicle battery pack
●● Conventional lead-acid batteries
P
●● Accurate current measurement for battery management
S
applications (SOC, SOH, SOF etc.).
Page 1/5
100916AFTS/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
CAB 300-C/SP2
E
C
I
M
E
N
Dimensions CAB 300-C/SP2 family (in mm)
Pin Out
CAN-L
B
CAN-H
C
GND
D
VC
S
P
A
Page 2/5
100916AFTS/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
CAB 300-C/SP2
Absolute maximum ratings (not operating)
Unit
Over-voltage
VC max
V
24
Reverse polarity
VC min
V
-50
Minimum supply voltage
VC min
V
6
continuous
Maximum supply voltage
VC max
V
18
continuous
VESD max
kV
4
Pins
RIS min
MΩ
Vd
kV
Electrostatic discharge voltage
Isolation resistance
Rms voltage for AC isolation test
Specification
V
32
N
Symbol
VC max
Conditions
E
Parameter
Load dump over-voltage
400 ms
1 minute
500
500 V ISO 16750-2
2.5
50Hz, 1 min
Operating characteristics
Parameter
Symbol
Specification
Unit
Min
Typical
Conditions
Max
M
Electrical Data
Primary current, measuring range
IPM
A
-350
Supply voltage
VC
V
8
Current consumption @ IP = 0 A
IC
mA
Current consumption @ IP = 250 A
IC
mA
Overall accuracy @ IP = 0 A
XG
mA
-10
0
10
In temperature range
Overall accuracy @ IP = 300 A
XG
mA
-1500
500
1500
In temperature range
Linearity error
εL
%
0.1
In temperature range
2
without digital filtering
350
13.5
16
80
IC is a function of IP
Signal delay
-0.1
ms
1
TA
°C
-40
BW
Hz
TBD
C
Frequency bandwidth
I
Performance Data
Ambient operating temperature
Can Output
CAN Interface characteristics:
full accuracy
30
1.5
+105
250
500
@ -3 dB attenuation
Optional internal filter can be implemented
●● CAN High Speed, SAE CAN Class C
E
●● High speed CAN transceiver: TJA1040
●● CAN protocol: Version 2.0A/B
●● Byte order: big endian (Motorola)
Parameter
CAN speed
Unit
Value
Comments
kbps
500
possible configuration: 125 to 1000
%
0.27
Message Description
P
CAN oscillator tolerance
ID
Name
S
Return Current IP (mA): 0x3C2
CAB300_IP
Filtered value
Data Lenght
(Nb bytes)
8
Type of
frame
Standard
Message launch
Signal Description
type
Cyclic message
10ms cycle
Signal Name
Start Bit End Bit
IP Value:
80000000H=0mA,
7FFFFFFFH=-1mA,
80000001H=1mA
IP_VALUE
0
31
b0: Error Information
(0=Normal, 1: failure
ERROR_INDICATION
32
32
b7 to b1: RxQuality
(0 to 100%)
ERROR_INFORMATION
33
39
Vacant bits (fixed to 0) VACANT_DATA_3BYTES
40
63
Page 3/5
100916AFTS/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Diagnostic Trouble Code (DTC)
ERROR INDICATION
ERROR INFORMATION
Error on dataflash CRC
FFFF FFFF
1
0x41
Fluxgate running at high frequency (<2.5 kHz) for more than 10 ms
FFFF FFFF
1
0x42
Fluxgate not oscillating for more than 20ms
FFFF FFFF
1
0x43
CAB entenred in fail safe mode
FFFF FFFF
1
0x44
Signal not available for more than 100ms
FFFF FFFF
1
0x46
Bridge voltage protection
FFFF FFFF
1
0x47
E
IP VALUE
M
Failure mode
N
CAB 300-C/SP2
I
Maximum global error over temperature range
2000
C
1500
500
0
-400
-300
-200
E
Accuracy curve
Error (mA)
1000
-100
-500
0
100
200
300
400
-1000
-1500
-2000
S
P
I (A)
Page 4/5
100916AFTS/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
CAB 300-C/SP2
PERFORMANCES PARAMETERS DEFINITIONS
value
Non linearity example
E
IP
N
Linearity:
The maximum positive or negative discrepancy with a reference
straight line IP value = f (IP).
Unit: linearity (%) expressed with full scale of IP max.
Reference
straight line
Max linearity error
IP
M
Linearity variation in IN %
S
P
E
C
I
Accuracy:
Accuracy is the maximum error between measured value and
a reference value.
Page 5/5
100916AFTS/0
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.