N AUTOMOTIVE CURRENT TRANSDUCER CAB 300-C/SP2 The CAB family is for battery monitoring applications where high accuracy and very low offset are required. Features Transducer using Fluxgate technology E Principle of Fluxgate transducers Introduction A low-frequency fluxgate transducer is made of a wound core which saturates under low induction. A current chopper switches the winding’s current to saturate the magnetic core alternatively at ± B max with a fixed frequency. M Fluxgate transducers use the change of the saturation’s point symmetry to measure the primary current. ●● Zero offset ●● Unlimited over-current capability Due to the principle of switching the current, all offsets (electric and magnetic) are cancelled. ●● Panel mounting ●● Unipolar + 12 V battery power supply ●● TA = - 40°C .. + 105°C ●● Accuracy (over temperature) I - εG= Sensitivity error < 0.5 % - εL= Linarity error < 0.1 % ●● Output signal: Current chopper - CAN.C (500 kbps) Signal aquisition and processing digital Output C ●● Optional internal digital low-pass frequency filter. Advantages ●● No offset error ●● High accuracy E ●● Low linearity error ●● Full galvanic isolation. Automotive applications ●● Hybrid and electric vehicle battery pack ●● Conventional lead-acid batteries P ●● Accurate current measurement for battery management S applications (SOC, SOH, SOF etc.). Page 1/5 100916AFTS/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com CAB 300-C/SP2 E C I M E N Dimensions CAB 300-C/SP2 family (in mm) Pin Out CAN-L B CAN-H C GND D VC S P A Page 2/5 100916AFTS/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com CAB 300-C/SP2 Absolute maximum ratings (not operating) Unit Over-voltage VC max V 24 Reverse polarity VC min V -50 Minimum supply voltage VC min V 6 continuous Maximum supply voltage VC max V 18 continuous VESD max kV 4 Pins RIS min MΩ Vd kV Electrostatic discharge voltage Isolation resistance Rms voltage for AC isolation test Specification V 32 N Symbol VC max Conditions E Parameter Load dump over-voltage 400 ms 1 minute 500 500 V ISO 16750-2 2.5 50Hz, 1 min Operating characteristics Parameter Symbol Specification Unit Min Typical Conditions Max M Electrical Data Primary current, measuring range IPM A -350 Supply voltage VC V 8 Current consumption @ IP = 0 A IC mA Current consumption @ IP = 250 A IC mA Overall accuracy @ IP = 0 A XG mA -10 0 10 In temperature range Overall accuracy @ IP = 300 A XG mA -1500 500 1500 In temperature range Linearity error εL % 0.1 In temperature range 2 without digital filtering 350 13.5 16 80 IC is a function of IP Signal delay -0.1 ms 1 TA °C -40 BW Hz TBD C Frequency bandwidth I Performance Data Ambient operating temperature Can Output CAN Interface characteristics: full accuracy 30 1.5 +105 250 500 @ -3 dB attenuation Optional internal filter can be implemented ●● CAN High Speed, SAE CAN Class C E ●● High speed CAN transceiver: TJA1040 ●● CAN protocol: Version 2.0A/B ●● Byte order: big endian (Motorola) Parameter CAN speed Unit Value Comments kbps 500 possible configuration: 125 to 1000 % 0.27 Message Description P CAN oscillator tolerance ID Name S Return Current IP (mA): 0x3C2 CAB300_IP Filtered value Data Lenght (Nb bytes) 8 Type of frame Standard Message launch Signal Description type Cyclic message 10ms cycle Signal Name Start Bit End Bit IP Value: 80000000H=0mA, 7FFFFFFFH=-1mA, 80000001H=1mA IP_VALUE 0 31 b0: Error Information (0=Normal, 1: failure ERROR_INDICATION 32 32 b7 to b1: RxQuality (0 to 100%) ERROR_INFORMATION 33 39 Vacant bits (fixed to 0) VACANT_DATA_3BYTES 40 63 Page 3/5 100916AFTS/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com Diagnostic Trouble Code (DTC) ERROR INDICATION ERROR INFORMATION Error on dataflash CRC FFFF FFFF 1 0x41 Fluxgate running at high frequency (<2.5 kHz) for more than 10 ms FFFF FFFF 1 0x42 Fluxgate not oscillating for more than 20ms FFFF FFFF 1 0x43 CAB entenred in fail safe mode FFFF FFFF 1 0x44 Signal not available for more than 100ms FFFF FFFF 1 0x46 Bridge voltage protection FFFF FFFF 1 0x47 E IP VALUE M Failure mode N CAB 300-C/SP2 I Maximum global error over temperature range 2000 C 1500 500 0 -400 -300 -200 E Accuracy curve Error (mA) 1000 -100 -500 0 100 200 300 400 -1000 -1500 -2000 S P I (A) Page 4/5 100916AFTS/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com CAB 300-C/SP2 PERFORMANCES PARAMETERS DEFINITIONS value Non linearity example E IP N Linearity: The maximum positive or negative discrepancy with a reference straight line IP value = f (IP). Unit: linearity (%) expressed with full scale of IP max. Reference straight line Max linearity error IP M Linearity variation in IN % S P E C I Accuracy: Accuracy is the maximum error between measured value and a reference value. Page 5/5 100916AFTS/0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com