S TARTERS & C ONTACTORS 2005-2006 5 EDITION $ ABB Allen-Bradley Aromat Furnas GE Joslyn Clark Mitsubishi Nordic Siemens Sprecher+Schuh Struthers-Dunn ACCESS Elevator Supply 800-266-8654 • Starters ACCESS ELEVATOR SUPPLY: Your Industry-Leading Source for: • Contactors • Relays • Contact Kits • Timers • Coils • Parts ACCESS Elevator Supply (800) 266-8654 Fax: (510) 652-5043 E-mail: Sales@aesupply.com Mailing address: P.O. Box 99047, Emeryville, CA 94662-9047 Physical address: Hours: Orders: 1302 65th Street, Emeryville, CA 94608 6:00 AM - 5:00 PM Pacific Time in by 4:00 PM Pacific Time shipped the same day Terms: Net 30 days with pre-approved credit, Visa/MasterCard/American Express welcome FOB: Point of shipment Starter & Contactor Industry Expertise Joe Roberts, President Access Elevator Supply Welcome to our newest and most comprehensive catalog of starters and contactors. As one of the largest stocking distributors of elevator starters and contactors in the U.S., we are pleased to provide optimal solutions for your needs. We offer: INDUSTRY EXPERTISE: Our sales professionals have extensive starter and contactor application expertise. We can help you determine which contactor or starter you require and also advise if an industry standard alternative may be more suitable for your specific needs. SAME DAY SHIPPING: We are located on the West Coast in Northern California so orders received by 4:00 PM Pacific Time (7:00 PM Eastern Time) are shipped the same day. Access can help you save time and money. Call us today to get the job done right. Sincerely, Joe Roberts Front Cover: TOP (left to right): Aromat FRM-65, ABB EHDB130, Nordic 72G MIDDLE ROW (left to right): Siemens 3RT1045, 42BF, 14FSH BOTTOM LEFT (clockwise): Sprecher+Schuh CA7-9, CAU7-12, CAUT7-12C, CAT7-12 Contact Kits For our full-color contact kit catalog, call Access today, 1 (800) 266-8654. Table of Contents C O N TA C TO R S Elevator Supply Conditions of Sale . . . . . . . . . . . . . . . 2 ∆ Application Information . . . . . . 3 Y-∆ Submersible Motor Data . . . . . . . . 13 CONTACTORS Application Guide . . . . . . . . . . . . . . 4 Contactor Photo Index . . . . . . . . . . . 5 Aromat . . . . . . . . . . . . . . . . . . . . . . . . 6 Sprecher+Schuh . . . . . . . . . . . . . . . . . 7 Siemens/Furnas NEMA . . . . . . . . . . 8 Siemens/Furnas DP . . . . . . . . . . . . . 9 Siemens Sirius IEC . . . . . . . . . . . . . . 10 Allen-Bradley Bulletin 100 . . . . . . . . 11 GE C-2000 IEC . . . . . . . . . . . . . . . . . . 12 ∆ Reversing Contactors Y-∆ Application Guide . . . . . . . . . . . . . . . ∆ Contactor Photo Index . . . . . . . Y-∆ Aromat . . . . . . . . . . . . . . . . . . . . . . . . Sprecher+Schuh . . . . . . . . . . . . . . . . . Door Reversing Contactors 22 23 24 25 Application Guide . . . . . . . . . . . . . . . 34 Aromat, S+S, Struthers-Dunn . . . . . 35 DC Drive Contactors Application Guide . . . . . . . . . . . . . . . 36 ABB, Mitsibishi, Joslyn-Clark. . . . . 37 Starters & Contactors -- Table of Contents -- Subject / Manufacturer . . . . . . . Page STARTERS Application Guide . . . . . . . . . . . . . . . Starter Photo Index . . . . . . . . . . . . . . Aromat . . . . . . . . . . . . . . . . . . . . . . . . Sprecher+Schuh . . . . . . . . . . . . . . . . . Siemens/Furnas ESP NEMA . . . . . Siemens Sirius IEC . . . . . . . . . . . . . . GE 300 Line NEMA . . . . . . . . . . . . . . GE C-2000 IEC . . . . . . . . . . . . . . . . . . 14 15 16 17 18 19 20 21 Application Guide . . . . . . . . . . . . . . . ∆ Starter Photo Index . . . . . . . . . . Y-∆ Aromat . . . . . . . . . . . . . . . . . . . . . . . . Sprecher+Schuh . . . . . . . . . . . . . . . . . 26 27 28 29 ∆ Reversing Starters Y-∆ Soft Starters - Siemens/Nordic C O N T E N T S ACCESS O F & Application Guide . . . . . . . . . . . . . . 30 Features . . . . . . . . . . . . . . . . . . . . . . 31 Set-Up & Dimensions . . . . . . . . 32-33 OVERLOAD RELAYS Siemens ESP 100 . . . . . . . . . . . . . . Aromat . . . . . . . . . . . . . . . . . . . . . . . ACCESSORIES / PARTS TA B L E S TA R T E R S 38 39 Aromat, ABB, GE . . . . . . . . . . . . 42-45 Joslyn-Clark, Mitsubishi . . . . . . . . 46-47 Siemens/Furnas . . . . . . . . . . . . . . . . 48-49 Sprecher+Schuh . . . . . . . . . . . . . . . . . 50 Westinghouse (Cutler-Hammer) . . . . . 51 PART NUMBER INDEX . . . . . . . . . . . . . . 52-60 2005-2006 All rights reserved Access Elevator Supply 800-266-8654 ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 1 Conditions of Sale S TA R T E R S & C O N TA C TO R S Access Standard Conditions of Sale Terms: Net 30 day payment with pre-approved credit, Visa/MasterCard/American Express cards welcome. C O N D I T I O N S FOB: Point of shipment Returns: Items normally stocked by Access can be returned for a 15% restocking charge plus freight in and out. Non-stocked items ordered and shipped from manufacturersare subject to their specific return policies. Items may not be returned without a proper RGA issued by Access. Important Note: The products contained in this catalog are designed and manufactured for use in standard industrial and commercial applications. These products must be installed and used in accordance with the manufacturers’ instructions and with the provisions of the National Electrical Code and all other state, local and industry standards. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment. O F Product Warranty: Only such warranties as are made by the manufacturer of the goods we provide are available to the buyer. These warranties do not cover defects caused by wear and tear, accident, misuse, or neglect. SELLER MAKES NO WARRANTY OF ANY KIND WHATEVER, EXPRESS, ORAL, STATUTORY, OR IMPLIED. ANY IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS HEREBY DISCLAIMED BY THE SELLER. Seller is not liable for any incidental, consequential, contingent, penal or special damages, losses, or expenses arising from the use of or the inability to use the goods for any purpose whatsoever. Incidental, consequential, contingent or special damages include, but are not limited to: Backcharges, labor costs, costs of removal, replacement, testing, or installation; loss of time, revenues, or profits; downtime, inconvenience, or commercial loss. S A L E Starters shown: (top right) Aromat F25 (left side, top to bottom) Siemens 3RT1016; Sprecher+Schuh CAT7-12; GE CL04 2 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply Fully-Rated Starters C O N TA C TO R S At Access Elevator Supply, we provide wye-delta starters and contactors that are fully-rated for the Horsepower and Full Load Amps of the motor. However, the overload relay for a wye-delta starter must be sized at 58% of the FLA of the motor. Q) Why 58% of the FLA? A) Because it’s the inverse of the square root of 3 (Give Joe a call if you’d like a more detailed explanation of this electrical engineering fact). Access Sells Fully-Rated Starters CONTACTOR TIP COMPARISON GE NEMA All contactors shown rated for 45 amps, 25 HP @ 460V AROMAT GE IEC Short Contact Life Larger Contact Tips turers carry this idea too far by also sizing IEC starters and large, comparatively Unfortunately, many controller manufacthe contactors at 58%, ignoring the high duty-cycle that many elevators are subjected to. This practice becomes even more problematic when compact IEC European-style contactors are used in elevator applications. These small devices have almost no extra capacity and under-sizing them only compounds the problem of short contact life expectancy. ACCESS Elevator Supply FAX 510-652-5043 A good compromise between small expensive NEMA starters is the Aromat hybrid line of starters and contactors. Well known for its ruggedness and long contact life, Aromat products are reason- ably priced as well. In addition to larger contact tips (see comparison above), Aromat’s patented “Snap C” return spring design opens the contactor quicker so there is significantly less arcing. 800-266-8654 3 S TA R T E R S & F U L LY- R AT E D S TA R T E R S Contactor Application Guide Contactor Application Guide 200V 230V 3 3 HP HP C O N TA C TO R A P P L I C AT I O N G U I D E 7-1/2 10 10 20 25 30 40 40 60 7-1/2 10 15 25 30 30 40 50 60 7-1/2 10 10 15 20 25 25 40 40 50 7-1/2 10 10 15 20 25 30 30 40 50 60 7-1/2 10 10 15 20 30 40 7-1/2 10 15 20 30 40 50 2 3 5 5 3 2 3 5 3 460V Max Motor HP Amps 5 10 20 25 40 50 60 75 100 125 5 7.5 10 15 20 25 30 40 50 60 60 75 100 150 5 10 15 25 30 50 75 100 ∗ ∗∗ 4 S TA R T E R S 18 27 40 45 75 90 105 125 135 175 9 12 16 23 30 37 43 60 72 85 95 110 140 180 18 27 40 45 60 90 115 135 NEMA Size 0 1 1-2/3 2 2-2/3 3 3-1/3 3-2/3 4 4-1/3 00 00 0 1 1 1 2 2 2 3 3 3 4 4 0 1 1-3/4 2 2-1/2 3 3-1/2 4 MFG Aromat Aromat Aromat Aromat Aromat Aromat Aromat Aromat Aromat Aromat S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Catalog Number FC20-AC * FC25-AC * FC35-AC * FC50-AC * FC65-AC * FC 80-AC * FC85-AC * FC125-AC * FC160-AC * FC190-AC * & C O N TA C TO R S (No overload relay) Standard Aux Height Contacts (NO-NC) (inches) CA7-9-10 * CA7-12-10 * CA7-16-10 * CA7-23-10 * CA7-30-10 * CA7-37-10 * CA7-43-10 * CA7-60-10 * CA7-72-10 * CA7-85-10 * CA6-95 * CA6-110 * CA6-140-EI* CA6-180-EI* 40CP32A * 40DP32A * 40EP32A * 40FP32A * 40GP32A * 40HP32A * 40IP32A * 40JG32A * To complete catalog number, please specify coil voltage. 2 2 2 2 2 2 2 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 1 2 2 2.76 3.4 5.5 5.5 6.5 6.5 6.5 8.25 11 11 0 0 0 0 0 0 0 0 4.31 4.31 4.31 4.88 4.88 6.13 6.13 7.81 0 0 0 0 0 0 0 0 0 0 1 1 1 1 3.2 3.2 3.2 3.2 3.2 3.2 3.2 4.8 4.8 4.8 6.7 6.7 6.7 6.7 Width Depth 2.69 3.09 3.72 3.72 4.17 4.17 4.17 4.25 5.51 5.51 3.4 3.6 4.41 4.41 5.34 5.34 5.34 5.5 7.1 7.1 (inches) 1.75 1.75 1.75 1.75 1.75 1.75 2.13 2.8 2.8 2.8 4.7 4.7 4.7 4.7 4.25 4.25 4.25 4.25 4.25 5.5 5.5 5.5 (inches) 3.2 ** 3.2 ** 3.2 ** 3.2 ** 3.2 ** 4 ** 4.1 ** 4.8 4.8 4.8 6.14 6.14 6.14 6.14 3.75 3.75 3.75 4 4 5.25 5.25 5.75 S+S contactors with true DC coils are deeper. Call Access for dimensions. 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & Contactor Index C O N TA C TO R S CONTACTOR INDEX Aromat . . . . . . . . . . . . . . . . 6 I N D E X Page 6 ..... 7 Siemens/Furnas NEMA . . . . . 8 C O N TA C TO R Sprecher+Schuh IEC Siemens/Furnas DP . . . . . . . . 9 Siemens Sirius IEC . . . . . . . 10 Allen-Bradley 100 Line . . . . . 11 GE C-2000 IEC . . . . . . . . . . 12 ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 5 Aromat Contactors S TA R T E R S & Aromat High performance at lower cost Contactors A R O M AT FC35, FC50 Long life contacts FC25 (FC35) Snap “C” spring provides superior arc suppression FC65, FC80, FC85 C O N TA C TO R S FC160, FC190 Compact design compared to NEMA devices 230V HP 460V HP Max Motor Amps NEMA Size Catalog Number 3 3 5 10 20 25 40 50 60 75 100 125 18 27 40 45 75 90 105 125 135 175 0 1 FC20-AC * FC25-AC * FC35-AC * FC50-AC * FC65-AC * FC80-AC * FC85-AC * FC125-AC * FC160-AC * FC190-AC * 6 ∗ 1-2/3 2 2-2/3 3 3-1/3 3-2/3 4 4-1/3 Ideal for elevator applications (FC160) 200V HP 7-1/2 10 15 25 30 30 40 50 60 Includes complete set of auxiliary contacts at no extra charge (FC85) FC125 7-1/2 10 10 20 25 30 40 40 60 C O N TA C TO R S Standard Aux Contacts 2 2 2 2 2 2 2 1 2 2 To complete catalog number, please specify AC coil voltage. 800-266-8654 FAX 510-652-5043 Width Depth 2.76 3.4 5.5 5.5 6.5 6.5 6.5 8.25 11 11 2.69 3.09 3.72 3.72 4.17 4.17 4.17 4.25 5.51 5.51 3.4 3.6 4.41 4.41 5.34 5.34 5.34 5.5 7.1 7.1 (inches) NO - NC 2 2 2 2 2 2 2 1 2 2 Height (inches) (inches) ACCESS Elevator Supply S+S Contactors C O N TA C TO R S Sprecher+Schuh Compact -- Excellent option for limited space -- Division of Rockwell Automation -- Contactors Wide range of both AC and DC coils Easily substituted for other IEC devices Interchangeable with Allen-Bradley Bulletin 100-C components 7-1/2 10 10 15 20 25 25 40 40 50 7-1/2 10 10 15 20 25 30 30 40 50 60 2 3 5 5 10 4 2 3 5 5 7.5 10 15 20 25 30 40 50 60 60 75 100 150 ∗ ∗∗ (CA7-16C) CA7-9C/12C/16C/23C/30C (CA6-140) (CA7-72) CA6-95/110/140/180 CA7-60/72/85 CA7-37/43 460V HP (CA7-9) Coil CA7-9/12/16/23/30 (CA7-37) 230V HP DC Coil Modular -- easy to change coils, add aux contacts 200V HP AC Max Motor Amps 9 12 16 23 30 37 43 60 72 85 95 110 140 180 NEMA Size 00 00 0 1 1 1 2 2 2 3 3 3 4 4 Catalog Number CA7-9-10 * CA7-12-10 * CA7-16-10 * CA7-23-10 * CA7-30-10 * CA7-37-10 * CA7-43-10 * CA7-60-10 * CA7-72-10 * CA7-85-10 * CA6-95 * CA6-110 * CA6-140-EI * CA6-180-EI * Standard Aux Height Contacts (NO-NC) (inches) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 1 1 1 1 To complete catalog number, please specify AC or DC coil voltage. 3.2 3.2 3.2 3.2 3.2 3.2 3.2 4.8 4.8 4.8 6.7 6.7 6.7 6.7 S+S contactors with true DC coils are deeper. Call Access for dimensions. ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 Width Depth 1.75 1.75 1.75 1.75 1.75 1.75 2.13 2.8 2.8 2.8 4.7 4.7 4.7 4.7 3.2 ** 3.2 ** 3.2 ** 3.2 ** 3.2 ** 4 ** 4.1 ** 4.8 4.8 4.8 6.14 6.14 6.14 6.14 (inches) (inches) 7 C O N TA C TO R S & S + S S TA R T E R S Siemens/Furnas NEMA Contactors S TA R T E R S Siemens/Furnas & C O N TA C TO R S Rugged NEMA industrial design S IEMENS/ F URNAS NEMA Contactors Easy to replace contacts or coil Large contacts and encapsulated coil 40CP/DP/EP N EMA C ONTACTORS 40FP/GP 200V HP 230V HP 7-1/2 10 10 15 20 30 40 7-1/2 10 15 20 30 40 50 3 8 3 460V HP 5 10 15 25 30 50 75 100 Max Motor Amps 18 27 40 45 60 90 115 135 ∗ Best electromechanical choice for heavy duty cycle applications such as elevators (40DP32A) (40FP32A) NEMA Size 0 1 1-3/4 2 2-1/2 3 3-1/2 4 40HP/IP Catalog Number 40CP32A * 40DP32A * 40EP32A * 40FP32A * 40GP32A * 40HP32A * 40IP32A * 40JG32A * Standard Aux Contacts NO - NC 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 To complete catalog number, please specify AC coil voltage. 800-266-8654 FAX 510-652-5043 (40HP32A) Height Width Depth 4.31 4.31 4.31 4.88 4.88 6.13 6.13 7.81 4.25 4.25 4.25 4.25 4.25 5.5 5.5 5.5 3.75 3.75 3.75 4 4 5.25 5.25 5.75 (inches) (inches) (inches) ACCESS Elevator Supply S TA R T E R S & Siemens/Furnas DP Contactors C O N TA C TO R S Siemens/Furnas 41NB20/30 (41NB20) (42EF) 42DF/EF Catalog Number 41NB20AFM 41NB21AFM 41NB30AFM 42AF35A* 42BF35A* 42CF35A* 41NB21 42FE/GE Poles Amps 2NO/1NC 25 2 3 3 3 ACCESS Elevator Supply 120VAC 25 120VAC 30 * 40 ∗ Coil Voltage 25 25 3 42AF/BF/CF 120VAC * * (42GE) Catalog Number 42DF35A* 42EF35A* 42FE35A*106 42GE35A*106 42HF35A* 42IF35A*106 45EG20A* 42HF/IF Poles 3 3 3 3 3 3 2 To complete catalog number, please specify AC coil voltage. FAX 510-652-5043 800-266-8654 Amps 50 60 75 90 120 150 30 (42BF) (42IF) Coil Voltage * * * * * * * 9 S I E M E N S / F U R N A S 45EG20 D P C O N TA C TO R S DP Contactors Siemens Sirius IEC Contactors S TA R T E R S & C O N TA C TO R S Siemens Sirius IEC Contactors S IEMENS 3RT1034 3RT1016 S IRIUS Catalog Max Motor 200V 230V 460V 3RT1016* 9 2 3 5 Number 3RT1023* 12 3RT1026* 25 3 17 5 I EC 7-1/2 15 10 10 25 40 10 C ONTACTORS 50 3 7-1/2 3RT1035* 3RT1036* HP 7.5 5 32 HP 3 7-1/2 15 5 10 10 20 15 30 15 40 3RT1044* 65 20 25 50 3RT1046* 95 30 30 75 3RT1045* 80 25 115 3RT1055* 150 3RT1064* 225 3RT1056* 3RT1065* 3RT1066* 3RT1075* 3RT1076* ∗ 800-266-8654 2 28 3RT1054* 10 HP 3RT1033* 3RT1034* 3RT1054 9 3RT1024* 3RT1025* 3RT1045 Amps 185 265 40 50 60 60 100 75 150 60 75 100 125 150 100 500 150 60 50 75 300 400 30 125 200 125 150 200 250 300 400 To complete catalog number, please specify AC or DC coil voltage. FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & A-B 100-Line Contactors C O N TA C TO R S Allen-Bradley -- Division of Rockwell Automation -- Bulletin 100 Line Contactors C ONTACTORS Siemens Sirius 1 0 0 - L I N E 3RT1054 100-B110N*3 ** BASE PLATE MOUNTING NOTE: Base plate mounting holes align exactly. No need to drill new holes in back plate. Catalog Number Max Motor Amps 200V HP 230V HP 460V HP Contactor Depth 100-B110N*3 110 30 40 75 6-1/8” 3RT1054* 115 ∗ ACCESS Elevator Supply 40 50 100 6-7/8” Base Plate Height ** Base Plate Width ** 6-1/16” 4-11/16” 6-3/8” 4-11/16” To complete catalog number, please specify AC coil voltage. FAX 510-652-5043 800-266-8654 11 A - B Allen-Bradley GE C-2000 IEC Contactors S TA R T E R S & C O N TA C TO R S GE C-2000 IEC Contactors G E C - 2 0 0 0 CL04 CL02 Catalog Number I E C CL00A310T* C O N TA C TO R S 5 22 3 15 10 10 15 CL08A310T* 68 20 CL10A310T* 96 30 80 CK75CE311* 140 CK09BE311* 192 CK08CE311* CK95BE311* CK10CE311* CK11CE311* ∗ 156 302 398 480 5 5 10 15 10 20 25 30 20 20 40 25 30 60 40 50 100 75 150 50 60 100 125 150 25 40 60 100 150 200 To complete catalog number, please specify AC or DC coil voltage. FAX 510-652-5043 HP 7.5 48 62 3 HP 5 CL06A310T* CL07A310T* 460V 7.5 10 34 230V 3 32 CL09A310T* 800-266-8654 17.5 CL25A310T* CL45A310T* 12 3 13.8 CL04A320T* CK75 10 CL01A310T* CL02A310T* CL06 Max Motor 200V Amps HP 50 75 125 250 300 400 ACCESS Elevator Supply S TA R T E R S & ACCESS Motor Data C O N TA C TO R S Motor Data for Submersible Hydraulic Elevator Motors AC Submersible Hydraulic Elevator Motor 20 25 30 40 50 FL PF (%) 217EAS020C001 217EAS020C015 “ 217EAS020C020 16,074 16,074 “ 16,074 76 76 “ 76 217EAS030C001 217EAS030C015 “ 217EAS030C020 20,296 20,296 “ 20,296 217EAS050C001 217EAS050C015 “ 217EAS050C020 29,861 29,861 “ 29,861 217EAS015C001 217EAS015C015 “ 217EAS015C020 217EAS025C001 217EAS025C015 “ 217EAS025C020 217EAS040C001 217EAS040C015 “ 217EAS040C020 14,120 14,120 “ 14,120 17,946 17,946 “ 17,946 FL RPM Volts 89 89 “ 89 3395 3395 “ 3395 200 230 460 575 65.4 56.2 28.1 22.4 31.2 25.5 12.8 10.2 79 79 “ 79 91 91 “ 91 3390 3390 “ 3390 200 230 460 575 90.0 78.2 39.1 31.2 36.0 31.0 15.5 12.0 81 81 “ 81 91 91 “ 91 3380 3380 “ 3380 142.0 123.0 61.5 49.4 42.7 37.5 18.8 15.0 73 73 “ 73 78 78 “ 78 81 81 “ 81 23,879 23,879 “ 23,879 ACCESS Motor Data courtesy of: 87 87 “ 87 3400 3400 “ 3400 91 91 “ 91 3400 3400 “ 3400 91 91 “ 91 3410 3410 “ 3410 ∗ NOTE: www.ImperialElectric.com (330) 734-3600 ACCESS Elevator Supply Amps (A) FAX 510-652-5043 200 230 460 575 200 230 460 575 200 230 460 575 200 230 460 575 Full Load 51.0 44.6 22.3 17.6 Delta ∗ 78.2 67.8 33.9 26.9 120.0 104.0 52.0 42.0 No Load 27.0 23.0 11.5 9.2 34.5 30.0 15.0 11.3 46.0 40.0 20.0 16.0 Locked Rotor 242 204 102 84 311 270 135 108 391 340 170 136 471 410 205 174 671 584 292 234 920 800 400 320 KVA Code F F F F WYE Locked Rotor 82 68 34 30 F F F F 104 90 45 36 F F F G 157 136 68 58 F F F F G G G G G G G G 130 113 57 45 224 195 97 78 307 268 133 106 Overload relays for across-the-line starters should be set at full load amps. Overload relays for wye-delta starters should be set at 58% of full load amps. 800-266-8654 D ATA FL EFF (%) M O TO R 15 Motor Losses BTU/HR A C C E S S HP Imperial Electric Part Number AC Squirrel Cage Induction, Ball Bearing, 3Ø, 60Hz, WYE Start, Delta Run, rated 80 Starts per Hour 13 Starter Application Guide 200V HP S TA R T E R S Starter (Across-the-Line) Application Guide 7-1/2 10 15 25 30 30 40 50 60 7-1/2 10 10 15 20 25 25 40 40 50 7-1/2 10 10 15 20 25 30 30 40 50 60 7-1/2 -10 -10 -15 -25 30 40 7-1/2 -10 -15 -20 -30 40 50 S TA R T E R 7-1/2 10 10 20 25 30 40 40 60 G U I D E 3 A P P L I C AT I O N 3 230V HP 2 3 5 5 2 3 3 14 2 3 5 2 3 3 460V HP 5 10 20 25 40 50 60 75 100 125 5 7.5 10 15 20 25 30 40 50 60 60 75 100 150 5 -10 -15 -15 25 30 -30 50 75 100 ∗ ∗∗ Max Motor NEMA Amps Size 18 27 40 45 75 90 105 125 135 175 9 12 16 23 30 37 43 60 72 85 95 110 140 180 18 18 27 27 40 40 45 45 60 60 90 90 115 135 0 1 1-2/3 2 2-2/3 3 3-1/3 3-2/3 4 4-1/3 00 00 0 1 1 1 2 2 2 3 3 3 4 4 0 0 1 1 1-3/4 1-3/4 2 2 2-1/2 2-1/2 3 3 3-1/2 4 MFG Aromat Aromat Aromat Aromat Aromat Aromat Aromat Aromat Aromat Aromat S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S S+S Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Furnas Catalog Number F20-AC * F25-AC * F35-AC * F50-AC * F65-AC * F 80-AC * F85-AC * F125-AC * F160-AC * F190-AC * C O N TA C TO R S (Single contactor w/overload relay) Standard Aux Height Contacts (NO - NC) (inches) CAT7-9-10 * CAT7-12-10 * CAT7-16-10 * CAT7-23-10 * CAT7-30-10 * CAT7-37-10 * CAT7-43-10 * CAT7-60-10 * CAT7-72-10 * CAT7-85-10 * CAT6-95 * CAT6-110 * CAT6-140-EI * CAT6-180-EI * 14CSD32A * 14CSE32A * 14DSE32A * 14DSF32A * 14ESF32A * 14ESG32A * 14FSF32A * 14FSH32A * 14GSH32A * 14GSJ32A * 14HSJ32A * 14HSK32A * 14ISL32A * 14JTM32A * & 2 2 2 2 2 2 2 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 1 2 2 6 6.8 8.3 8.3 8.8 8.8 8.8 11 15.7 15.7 0 0 0 0 0 0 0 0 0 0 1 1 1 1 5.2 5.2 5.2 5.2 5.4 5.4 5.4 7.4 7.4 7.4 13.4 13.4 13.4 13.4 7.0 7.0 7.0 7.0 7.0 7.0 8.1 8.1 8.1 8.1 9.75 9.75 9.75 11.1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 To complete catalog number, please specify coil voltage and overload relay amps. S+S contactors with true DC coils are deeper. Call Access for dimensions. 800-266-8654 FAX 510-652-5043 Width Depth 2.69 3.09 3.72 3.72 4.17 4.17 4.17 4.25 5.51 5.51 3.4 3.6 4.41 4.41 5.34 5.34 5.34 5.5 7.1 7.1 (inches) 1.75 1.75 1.75 1.75 1.75 1.75 2.13 2.8 2.8 2.8 4.7 4.7 4.7 4.7 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 4.5 4.5 4.5 4.5 (inches) 3.2 ** 3.2 ** 3.2 ** 3.2 ** 3.2 ** 4 ** 4.1 ** 4.8 4.8 4.8 6.14 6.14 6.14 6.14 3.5 3.5 3.5 3.5 3.5 3.5 3.75 3.75 3.75 3.75 5.2 5.2 5.2 5.75 ACCESS Elevator Supply S+S Starters C O N TA C TO R S Sprecher+Schuh -- Division of Rockwell Automation -- Starters Compact -- Excellent option for limited space Wide range of both AC and DC coils AC Easily substituted for other IEC devices Coil (CAT7-12) Modular -- easy to change coils, add aux contacts CAT7-9/12/16/23/30 Interchangeable with Allen-Bradley Bulletin 100-C components Wide range adjustable overload relay 200V HP 2 3 5 5 7-1/2 10 10 15 20 25 25 40 40 50 230V HP 460V HP 7-1/2 10 10 15 20 25 30 30 40 50 60 7-1/2 10 15 20 25 30 40 50 60 60 75 100 150 2 3 5 5 ∗ ∗∗ (CAT7-37) Max Motor Amps 9 12 16 23 30 37 43 60 72 85 95 110 140 180 Size 00 00 0 1 1 1 2 2 2 3 3 3 4 4 CAT7-37/43 (CAT7-72) (CAT6-140) CAT7-60 CAT7-72/85 CAT6-95/110 CAT6-140/180 Catalog Number CAT7-9-10 * CAT7-12-10 * CAT7-16-10 * CAT7-23-10 * CAT7-30-10 * CAT7-37-10 * CAT7-43-10 * CAT7-60-10 * CAT7-72-10 * CAT7-85-10 * CAT6-95 * CAT6-110 * CAT6-140-EI* CAT6-180-EI* Standard Aux Contacts (NO-NC) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 1 1 1 1 Height Width Depth 5.2 5.2 5.2 5.2 5.4 5.4 5.4 7.4 7.4 7.4 13.4 13.4 13.4 13.4 1.75 1.75 1.75 1.75 1.75 1.75 2.13 2.8 2.8 2.8 4.7 4.7 4.7 4.7 3.2 ** 3.2 ** 3.2 ** 3.2 ** 3.2 ** 4 ** 4.1 ** 4.8 4.8 4.8 6.14 6.14 6.14 6.14 (inches) (inches) To complete catalog number, please specify AC or DC coil voltage and overload relay amps. S+S starters with true DC coils are deeper. Call Access for dimensions. ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 (inches) 17 S TA R T E R S & S + S S TA R T E R S Siemens/Furnas ESP NEMA Starters S TA R T E R S Siemens/Furnas & C O N TA C TO R S Rugged NEMA industrial design S IEMENS/ F URNAS ESP NEMA Starters ESP electronic overload relay is adjustable over a wide range and provides phase-loss protection. Easy to replace contacts or coil 14CSD/CSE/DSE 14DSF/ESF/ESG Large contacts & encapsulated coil Best electromechanical choice for heavy duty-cycle elevator applications (14CSE) E SP N EMA S TARTERS (14FSH) (14HSJ) 14FSF/FSH 14GSH/GSJ 14HSJ/HSK/ISL 200V 230V 460V Max Motor NEMA 2 2 5 18 0 14CSD32A * HP 3 3 HP 3 HP -- Amps 18 Size 0 Catalog Standard Aux Number 14CSE32A * Range (Amps) 7.0 3.5 3.5 9-18 7.0 3.5 3.5 1 0 7.0 3.5 3.5 -- 15 40 1-3/4 14ESF32A * 1 0 7.0 3.5 3.5 -- 15 45 2 0 8.1 15 25 45 15 20 -- 60 2-1/2 25 30 50 90 3 14HSK32A * 40 50 100 4 14JTM32A * 18 (inches) 14DSE32A * 10 30 0 (inches) 1 10 -- 1 -- -- 40 -- -- 30 30 75 27 1 40 60 90 115 135 ∗ 14DSF32A * 1 0 1-3/4 14ESG32A * 1 0 2 14FSH32A * 1 0 14FSF32A * 1 7.0 3.5 8.1 3.5 14GSH32A * 1 0 8.1 3 14HSJ32A * 1 0 9.75 3-1/2 14ISL32A * 1 0 1 0 1 0 1 0 3.5 7.0 2-1/2 14GSJ32A * 3.5 3.5 3.5 2.5-10 9-18 13-27 13-27 3.5 20-40 3.75 22-45 3.75 3.75 13-27 22-45 8.1 3.5 3.75 30-60 9.75 4.5 5.2 45-90 4.5 4.5 9.75 11.0 To complete catalog number, please specify AC coil voltage. 800-266-8654 O/L Relay (inches) 27 10 -- 0 Depth 10 7-1/2 -- 1 Width 3 7-1/2 -- Contacts (NO-NC) Height FAX 510-652-5043 4.5 5.2 5.2 5.75 30-60 57-115 67-135 ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Siemens Sirius IEC Starters Siemens Sirius Catalog Max Motor 200V 230V 460V 3RT1016* 9 2 3 5 12 3RT1026* 25 17 2 3 7-1/2 7-1/2 15 10 10 25 15 15 40 5 7-1/2 3RT1035* 40 10 3RT1036* 3RT1044* 3RT1045* 3RT1046* 3RT1054* 50 65 80 95 115 3RT1055* 150 3RT1064* 225 3RT1056* 3RT1065* 3RT1066* 3RT1075* 3RT1076* ∗ 185 265 20 25 30 40 50 60 60 5 10 15 25 30 30 50 75 125 200 3RT1034 75 125 150 200 250 300 400 To complete catalog number, please specify AC or DC coil voltage and overload relay amps. ACCESS Elevator Supply 3RT1016 60 150 150 150 30 75 60 125 500 20 100 100 100 10 50 75 300 400 5 7.5 28 32 3 HP 3 3RT1033* 3RT1034* HP I E C 9 3RT1024* 3RT1025* HP S I R I U S 3RT1023* Amps S I E M E N S Number S TA R T E R S IEC Starters FAX 510-652-5043 3RT1045 800-266-8654 3RT1054 19 GE 300 NEMA Starters S TA R T E R S GE 300 Line & C O N TA C TO R S Heavy-duty NEMA industrial design NEMA Starters Easy to replace coils and contacts G E NEMA Type 1, 3R, and 12 enclosures readily available 3 0 0 N E M A S TA R T E R S (CR306C) CR306D CR306A/B/C 200V HP 230V HP 460V HP Max Motor Amps NEMA Size 3 3 5 18 0 1-1/2 1-1/2 2 9 7-1/2 7-1/2 10 27 25 30 50 90 10 40 75 15 25 50 100 100 200 ∗ 20 (CR306E) Catalog Number 00 CR306A00 * 1 -- CR306C00 * 1 -- CR306E00 * 1 CR306B00 * 2 CR306D00 * 135 4 CR306F00 * 270 5 Standard Aux Height Contacts (NO-NC) (inches) 1 45 3 CR306E/F CR306G00 * 1 1 1 1 7 -- 7 -- 9 Width (inches) (inches) 5.5 3.7 5.5 4.6 5.5 7 3.7 -- 11.6 6.6 6.5 -- 14 11.5 9 -- 11.6 To complete catalog number, please specify AC coil voltage and overload relay amps. 800-266-8654 3.7 Depth FAX 510-652-5043 6.6 5.5 6.5 ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S GE C-2000 IEC Starters GE C-2000 IEC Starters 3 17.5 5 5 CL01A310T* 13.8 CL25A310T* 22 CL02A310T* CL04A320T* 3 7.5 5 7.5 15 10 10 25 10 CL06A310T* 48 15 15 CL08A310T* 68 20 25 CL45A310T* CL07A310T* CL09A310T* CL10A310T* 34 62 80 96 5 3 32 20 25 30 10 10 20 40 30 60 50 75 CK75CE311* 140 40 50 100 CK09BE311* 192 60 75 150 CK08CE311* CK95BE311* CK10CE311* CK11CE311* ∗ 156 302 398 480 50 100 125 150 60 100 150 200 CL04 30 20 40 125 250 300 400 CL10 To complete catalog number, please specify AC or DC coil voltage, and overload relay amps. ACCESS Elevator Supply S TA R T E R S 3 HP I E C 10 460V C - 2 0 0 0 CL00A310T* Max Motor 200V 230V Amps HP HP G E Catalog Number FAX 510-652-5043 800-266-8654 21 Contactor Application Guide S TA R T E R S & Y-∆ (Reversing) Contactor Application Guide C O N TA C TO R 200V HP 230V HP 7-1/2 7-1/2 10 27 10 15 25 45 3 10 20 25 30 A P P L I C AT I O N 40 3 10 25 30 30 40 460V Max Motor HP Amps 5 1-2/3 Aromat FCRM35-AC * 4 4 5.5 8.9 4.41 75 2-2/3 Aromat FCRM65-AC * 4 4 6.5 10.6 5.34 60 105 3-1/3 Aromat FCRM85-AC * 4 4 6.5 10.6 5.34 4 Aromat FCRM160-AC * 4 4 11 13 7.1 40 50 75 90 125 5 9 125 2 3.2 3.9 3.2 ** CAU7-37-22 * 2 2 3.2 3.9 4 ** G U I D E 40 50 100 50 40 60 75 125 ∗ ∗∗ 22 S+S CAU7-30-22 * S+S CAU7-43-22 * 1 2 60 40 S+S 43 60 72 85 1 S+S 2 S+S 2 3 95 3 140 4 110 180 CAU7-9-22 * 0 30 37 S+S S+S S+S S+S 3 S+S 4 S+S S+S CAU7-16-22 * CAU7-60-22 * CAU7-72-22 * CAU7-85-22 * 2 2 2 2 2 2 2 3.2 3.9 3.2 ** 2 3.2 3.9 3.2 ** 3.2 2 4.8 2 4.8 2 CAU6-140-EI * 2 2 2 3.2 2 2 CAU6-180-EI * 3.2 2 2 2 7.1 2 CAU6-95 * CAU6-110 * 13 5.5 2 16 15 30 11 9.8 CAU7-23-22 * 10 25 8.25 5.34 S+S 10 60 2 10.6 2 1 30 6.5 4.41 2 30 50 4 8.9 CAU7-12-22 * 20 25 2 5.5 3.6 S+S 00 10 40 FCRM125-AC * 4 7.6 00 23 20 Aromat 4 3.4 4 15 25 FCRM80-AC * 4 4 4 7-1/2 25 3-2/3 Aromat FCRM50-AC * 4 FCRM190-AC * 5 20 3 Aromat FCRM25-AC * Aromat 12 15 2 Aromat 4-1/3 7.5 10 1 175 3 10 3.4 40 2 7-1/2 7.5 (inches) 2.76 2 5 Depth (inches) 4 135 5 Width 4 100 3 Standard Aux Height Contacts (NO-NC) (inches) FCRM20-AC * 50 60 Catalog Number Aromat 40 60 MFG (No Overload Relay) 0 20 18 Size C O N TA C TO R S 4.8 3.9 3.9 3.2 ** 3.2 ** 4.6 4.1 ** 6 4.8 6 6 4.8 4.8 13.4 10.6 6.2 13.4 10.6 6.2 2 13.4 2 13.4 10.6 10.6 6.2 6.2 To complete catalog number, please specify AC or DC coil voltage. S+S contactors with true DC coils are deeper. Call Access for dimensions. 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Reversing Contactor Index CONTACTOR INDEX C O N TA C TO R Page ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 R E V E R S I N G Aromat . . . . . . . . . . . . . . . . . . . . . . . . . 24 Sprecher+Schuh . . . . . . . . . . . . . . . . . . . . . . . . . I N D E X Y-∆ (Reversing) 25 23 Aromat Reversing Contactors S TA R T E R S & C O N TA C TO R S Aromat Y-∆ (Reversing) Contactors A R O M AT (No Overload Relay) High performance at lower cost Long life contacts R E V E R S I N G (FCRM35) C O N TA C TO R S 230V HP 7-1/2 10 10 20 25 30 40 40 60 7-1/2 10 15 25 30 30 40 50 60 24 FCRM65/80/85 3 (FCRM160) FCRM125 200V HP 3 (FCRM65) FCRM35/50 (FCRM125) 460V HP 5 10 20 25 40 50 60 75 100 125 Snap “C” spring provides superior arc suppression Max Motor Amps 18 27 40 45 75 90 105 125 135 175 ∗ Size 0 1 1-2/3 2 2-2/3 3 3-1/3 3-2/3 4 4-1/3 Includes complete set of auxilliary contacts at no extra charge Compact design compared to NEMA devices Ideal for elevator applications FCRM160/190 Catalog Number FCRM20-AC * FCRM25-AC * FCRM35-AC * FCRM50-AC * FCRM65-AC * FCRM80-AC * FCRM85-AC * FCRM125-AC * FCRM160-AC * FCRM190-AC * Standard Aux Contacts (NO-NC) 4 4 4 4 4 4 4 2 4 4 4 4 4 4 4 4 4 2 4 4 Height Width Depth 2.9 3.4 5.5 5.5 6.5 6.5 6.5 8.25 11 11 7.5 7.6 8.9 8.9 10.6 10.6 10.6 9.8 13 13 3.4 3.6 4.41 4.41 5.34 5.34 5.34 5.5 7.1 7.1 (inches) To complete catalog number, please specify AC coil voltage. 800-266-8654 FAX 510-652-5043 (inches) (inches) ACCESS Elevator Supply S+S Reversing Contactors C O N TA C TO R S Sprecher+Schuh Compact size Wide range AC, DC coils -- Division of Rockwell Automation -- Modular -- easy to change coils, add aux contacts AC Interchangeable with A-B Bulletin 100-C components Coil (CAU7-12) CAU7-9/12/16/23/30 DC Coil (CAU6-140) (CAU7-30C) CAU7-9C/12C/16C/23C/30C CAU6-95/110/140/180 200V HP 2 3 5 5 7-1/2 10 10 15 20 25 25 40 40 50 230V HP 460V HP 7-1/2 10 10 15 20 25 30 30 40 50 60 7-1/2 10 15 20 25 30 40 50 60 60 75 100 150 2 3 5 5 ∗ ∗∗ Max Motor Amps 9 12 16 23 30 37 43 60 72 85 95 110 140 180 Size 00 00 0 1 1 1 2 2 2 3 3 3 4 4 Catalog Number CAU7-9-22 * CAU7-12-22 * CAU7-16-22 * CAU7-23-22 * CAU7-30-22 * CAU7-37-22 * CAU7-43-22 * CAU7-60-22 * CAU7-72-22 * CAU7-85-22 * CAU6-95 * CAU6-110 * CAU6-140-EI * CAU6-180-EI * Standard Aux Contacts (NO-NC) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 To complete catalog number, please specify AC or DC coil voltage. Height Width Depth 3.2 3.2 3.2 3.2 3.2 3.2 3.2 4.8 4.8 4.8 13.4 13.4 13.4 13.4 3.9 3.9 3.9 3.9 3.9 3.9 4.6 6 6 6 10.6 10.6 10.6 10.6 3.2 ** 3.2 ** 3.2 ** 3.2 ** 3.2 ** 4 ** 4.1 ** 4.8 4.8 4.8 6.2 6.2 6.2 6.2 (inches) S+S contactors with true DC coils are deeper. Call Access for dimensions. ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 (inches) (inches) 25 C O N TA C TO R S Y-∆ (Reversing) Contactors (No Overload Relay) Easily substituted for other IEC devices R E V E R S I N G & S + S S TA R T E R S Starter Application Guide S TA R T E R S & Y-∆ (Reversing) Starter Application Guide 200V HP 230V HP S TA R T E R 7-1/2 7-1/2 10 27 10 15 25 45 A P P L I C ATO N 40 3 10 20 25 30 3 10 25 30 30 40 40 60 60 2 3 460V Max Motor NEMA HP Amps Size 5 18 1-2/3 Aromat 75 2-2/3 Aromat 105 3-1/3 Aromat 4 Aromat 2 3 S+S G U I D E S+S 3 S+S 85 3 25 40 40 50 30 40 50 60 60 75 100 150 95 110 140 180 ∗ ∗∗ ∗∗∗ 26 3 4 4 4 8.7 10.6 5.34 14.6 13 7.1 FRM160-AC * 4 CAUT7-12-22 * CAUT7-23-22 * CAUT7-37-22 * 8.7 4 CAUT7-43-22 * 2 60 4 6.9 4 CAUT7-30-22 * S+S 30 FRM85-AC * 4 S+S 2 25 5.34 2 43 72 10.6 CAUT7-16-22 * 30 50 8.7 4 S+S 15 25 4 5.2 1 2 4 2 1 60 FRM65-AC * 4 2 30 40 4.41 2 20 20 8.9 CAUT7-9-22 * S+S 10 15 6.9 6.4 14.6 16 37 4 4 4 10 25 4 4 4 S+S 10 FRM35-AC * FRM25-AC * FRM190-AC * 1 10 3.4 9.8 13 7.1 3.9 3.2 ** 2 2 5.4 3.9 3.2 ** 2 2 5.4 4.6 4.1 ** 6 4.8 2 2 2 5.2 2 5.4 S+S CAUT7-85-22 * 2 2 7.4 2 2 7.4 3.9 3.9 3.9 6 6 CAUT6-95 * 2 2 13.4 10.6 CAUT6-140-EI * 2 2 13.4 10.6 CAUT6-180-EI * 5.5 5.2 7.4 CAUT6-110 * 5.34 2 2 2 S+S 10.6 4.41 3.2 ** 2 S+S 8.9 3.6 3.9 CAUT7-60-22 * CAUT7-72-22 * 7.6 5.2 S+S S+S (inches) 4 10.5 23 15 7.5 (inches) 4 2 S+S 0 4.7 (inches) 2 00 00 Depth FRM125-AC * 12 9 Width Aromat Aromat 5 Height FRM80-AC * 4-1/3 2 Contacts (NO-NC) Aromat 175 135 Standard Aux FRM50-AC * 125 100 (Includes overload relay) Aromat 3-2/3 7-1/2 20 Aromat 125 5 10 40 1 75 7-1/2 7-1/2 FRM20-AC * 90 60 50 5 Aromat 40 3 5 0 20 50 MFG Catalog Number C O N TA C TO R S 2 2 2 13.4 2 13.4 3.2 ** 3.2 ** 4 ** 4.8 4.8 6.2 *** 10.6 6.2 *** 10.6 6.2 *** 6.2 *** To complete catalog number, please specify AC or DC coil voltage. S+S contactors with true DC coils are deeper. Call Access for dimensions. Dimensions shown are those of the back plate. Dimensions of the actual components are smaller. Call Access for more information. 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Reversing Starter Index Y-∆ (Reversing) 28 Sprecher+Schuh . . . . . . . . 29 Siemens/Nordic . . . . . . . . . 30 ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 27 S TA R T E R Aromat . . . . . . . . . . . . . . R E V E R S I N G Page I N D E X STARTER INDEX Aromat Reversing Starters S TA R T E R S Aromat (Includes overload relay) A R O M AT Long life contacts (FRM65) FRM65/80/85 R E V E R S I N G (FRM35) FRM35/50 S TA R T E R S FRM160/190 FRM125 7-1/2 10 10 20 25 30 40 40 60 7-1/2 10 15 25 30 30 40 50 60 3 28 460V HP 3 ∗ 5 10 20 25 40 50 60 75 100 125 Snap “C” spring provides superior arc suppression Includes complete set of auxilliary contacts at no extra charge Compact design compared to NEMA devices (FRM160) 230V HP C O N TA C TO R S High performance at lower cost Y-∆ (Reversing) Starters 200V HP & Max Motor Amps 18 27 40 45 75 90 105 125 135 175 Size 0 1 1-2/3 2 2-2/3 3 3-1/3 3-2/3 4 4-1/3 Catalog Number FRM20-AC * FRM25-AC * FRM35-AC * FRM50-AC * FRM65-AC * FRM80-AC * FRM85-AC * FRM125-AC * FRM160-AC * FRM190-AC * Standard Aux Contacts (NO-NC) 4 4 4 4 4 4 4 2 4 4 4 4 4 4 4 4 4 2 4 4 Wide range adjustable overload relay Ideal for elevator applications Height Width Depth 4.7 6.4 6.9 6.9 8.7 8.7 8.7 10.5 14.6 14.6 7.5 7.6 8.9 8.9 10.6 10.6 10.6 9.8 13 13 3.4 3.6 4.41 4.41 5.34 5.34 5.34 5.5 7.1 7.1 (inches) To complete catalog number, please specify AC coil voltage and overload relay amps. 800-266-8654 FAX 510-652-5043 (inches) (inches) ACCESS Elevator Supply S+S Reversing Starters C O N TA C TO R S Sprecher+Schuh Compact size -- Division of Rockwell Automation -- Wide range AC, DC coils Easily substituted for other IEC devices Modular - easy to change coils, add aux contacts Interchangeable with A-B Bulletin 100-C components CAUT7-9/12/16/23/30 AC DC CAUT6-140 200V HP 2 3 5 5 7-1/2 10 10 15 20 25 25 40 40 50 230V HP 460V HP 7-1/2 10 10 15 20 25 30 30 40 50 60 7-1/2 10 15 20 25 30 40 50 60 60 75 100 150 2 3 5 5 Max Motor Amps 9 12 16 23 30 37 43 60 72 85 95 110 140 180 Coil Coil (CAUT7-12C) CAUT7-9C/12C/16C/23C/30C Size 00 00 0 1 1 1 2 2 2 3 3 3 4 4 Catalog Number CAUT7-9-22 * CAUT7-12-22 * CAUT7-16-22 * CAUT7-23-22 * CAUT7-30-22 * CAUT7-37-22 * CAUT7-43-22 * CAUT7-60-22 * CAUT7-72-22 * CAUT7-85-22 * CAUT6-95 * CAUT6-110 * CAUT6-140-EI * CAUT6-180-EI * Standard Aux Contacts (NO-NC) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Height Width Depth 5.2 5.2 5.2 5.2 5.4 5.4 5.4 7.4 7.4 7.4 13.4 13.4 13.4 13.4 3.9 3.9 3.9 3.9 3.9 3.9 4.6 6 6 6 10.5 10.5 10.5 10.5 3.2 ** 3.2 ** 3.2 ** 3.2 ** 3.2 ** 4 ** 4.1 ** 4.8 4.8 4.8 6.2 *** 6.2 *** 6.2 *** 6.2 *** (inches) (inches) (inches) ∗ To complete catalog number, please specify AC or DC coil voltage and overload relay amps. ∗∗ S+S contactors with true DC coils are deeper. Call Access for dimensions. ∗∗∗ Dimensions shown are those of the back plate. Dimensions of actual components are smaller. Call for more info. ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 29 S TA R T E R S Y-∆ (Reversing) Starters R E V E R S I N G & S + S S TA R T E R S Hydraulic Elevator App Guide S TA R T E R S & C O N TA C TO R S Siemens/Nordic Soft-Start Hydraulic Elevator Application Guide ∗ Table 1: H Y D R A U L I C For use with Wye-Delta wound motors 200-460 Volts Table 2: For use with E L E VATO R Wye-Delta wound motors 575-600 Volts (primarily Canada) Table 3: For use with A P P Across-the-Line motors 200-460 Volts G U I D E Table 4: For use with Across-the-Line motors 575-600 Volts (primarily Canada) 30 HP @ 200V 5 7.5 10 15 20 25 30 40 50 75 HP @ 460V 15 25 30 40 50 60 75 100 125 HP @ 200V -5 7.5 7.5 10 15 20 25 40 HP @ 460V 10 15 20 25 30 40 50 60 HP @ 230V 7.5 10 15 20 25 30 40 50 60 100 HP @ 575V 20 30 40 50 60 75 100 125 150 HP @ 230V 5 7.5 10 10 15 20 25 30 50 HP @ 575V 15 20 25 30 40 50 60 75 HP @ 460V 15 25 30 40 50 60 75 100 125 -- Rated Current (Amps) Rated Current (Amps) 22 35 42 55 68 80 105 130 156 HP @ 460V 10 15 20 25 30 40 50 60 -- 22 35 42 55 68 80 105 130 156 252 Rated Current (Amps) 18 22 28 35 42 55 68 80 7 - 27 12 - 44 14 - 53 18 - 69 22 - 85 26 - 100 35 - 131 43 - 163 52 - 196 83 - 315 Overload Range (Amps) Rated Current (Amps) 18 22 28 35 42 55 68 80 130 Overload Range (Amps) 7 - 27 12 - 44 14 - 53 18 - 69 22 - 85 26 - 100 35 - 131 43 - 163 52 - 196 Overload Range (Amps) 6 - 25 8 - 30 10 - 39 13 - 49 15 - 57 20 - 75 24 - 93 29 - 112 48 - 181 Overload Range (Amps) 6 - 25 8 - 30 10 - 39 13 - 49 15 - 57 20 - 75 24 - 93 29 - 112 Current Limit Range (Amps) 26 - 94 41 - 148 49 - 179 64 - 234 79 - 289 93 - 340 121 - 447 151 - 553 181 - 663 292 - 1071 Current Limit Range (Amps) 26 - 94 41 - 148 49 - 179 64 - 234 79 - 289 93 - 340 121 - 447 151 - 553 181 - 663 Current Limit Range (Amps) 24 - 85 28 - 10 36 - 135 45 - 166 53 - 196 70 - 257 87 - 319 104 - 382 168 - 618 Current Limit Range (Amps) 24 - 25 28 - 103 36 - 135 45 - 166 53 - 196 70 - 257 87 - 319 104 - 382 ∗ For traction elevator applications, call Access 800-266-8654 FAX 510-652-5043 Manufacturer Catalog Number 72EG34AFP 72GG34AFP 72HG34AFP 72JG34AFP 72KG34AFP 72LG34AFP 72MG34AFP 72NG34AFP 72PG34AFP 72RG34AFP Manufacturer Catalog Number 72EG35AFP 72GG35AFP 72HG35AFP 72JG35AFP 72KG35AFP 72LG35AFP 72MG35AFP 72NG35AFP 72PG35AFP Manufacturer Catalog Number 72GG34AFP 72HG34AFP 72JG34AFP 72KG34AFP 72LG34AFP 72MG34AFP 72NG34AFP 72PG34AFP 72RG34AFP Manufacturer Catalog Number 72GG35AFP 72HG35AFP 72JG35AFP 72KG35AFP 72LG35AFP 72MG35AFP 72NG35AFP 72PG35AFP ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Siemens / Nordic Starter Features Siemens / Nordic The Industry Standard for Electronic Soft Starters Siemens / Nordic elevator starters are specifically designed and manufactured for the elevator industry with over 100,000 units installed & running. Heavy duty, full size, and fully rated @ 80 starts per hour Not a light duty uprated miniature electronic starter, Siemens /Nordic starters set the industry standard Easy to read self-diagnostics, easy to set motor amps & start time All done with the keypad and two-line LCD display, just follow the prompts - no flashing LEDs ! Provides smooth, stepless soft-start of elevator motor No more dimming lights Protects sensitive medical and diagnostic equipment and computers Reduces wear of motor, pump, valves, seals, and other mechanical components Built-in phase loss / phase reversal plus field adjustable electronic overload relay Fully protects expensive elevator motors and service components No moving parts Eliminates the expense of replacing contact kits Significant noise reduction No electromechanical contactors closing and opening delivers quiet operation Automatic status monitoring Siemens / Nordic starters automatically check for proper motor connections upon initial start-up Windows-based computer diagnostic software also available Call Access today for low price & same-day shipment on all Siemens / Nordic elevator starters ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 31 SIEMENS/NORDIC STARTER FEATURES Elevator Starter Features Elevator Starter Installation S TA R T E R S & C O N TA C TO R S Siemens / Nordic Elevator Starter Installation Ease of Set-Up S TA R T E R One of the many reasons that the Siemens/Nortic elevator starter is the industry’s preferred product is its ease of set-up. I N S TA L L AT I O N After making the control power connections (remember, only use 120VAC for the motor run signal on terminal 4), make the line & load connections. The starter is wired at the factory ∗ for a wye-delta motor, 6 or 12 leads. Single Voltage Motors 6-lead motor (208 - 575 VAC) T1 1 ∗ 32 T2 2 T3 3 T4 4 T5 5 T6 6 After making the power and control connections, set the starting amps and overload amps using the keypad. “Starting Amps” is the maximum number of amps that the starter will allow the motor to draw when it starts. Keep in mind that while lower settings reduce the inrush currents, they also increase the starting time. This setting should not be less than twice the motor’s Full Load Amps. The factory default setting is 425% of the starter’s current rating as measured in amps. Next, the Overload amps should be input using the keypad. This setting should be set at or below the FLA of the motor. Dual Voltage Motors Low Voltage Connections 12-lead motor (220 - 240 VAC) T1 1,7 T2 2,8 T3 3,9 T4 T5 T6 10,4 11,5 12,6 High Voltage Connections 12-lead motor (460 - 480 VAC) T1 1 T2 2 T3 3 T4 10 T5 11 T6 12 Connect: 4&7 5&8 6&9 If you have a 9-lead motor or a 3 or 6-lead across-the-line motor, you must reconnect the starter to run across the line. Check to make sure the starter can handle the larger draw of an across-the-line motor. For across the line connections, consult the instruction book. 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & Siemens / Nordic Starter Dimensions C O N TA C TO R S Siemens / Nordic Elevator Starter Dimensions Catalog Number Height Width 72LG34AFP - 72PG34AFP 11.5” 11” 72EG34AFP - 72KG34AFP 11.5” 72RG34AFP 72EG35AFP - 72KG35AFP 11” 5.63” 12” 16.75” 7.16” 11.5” 11” 7.13” 11.5” 72LG35AFP 72MG35AFP - 72PG35AFP Depth 12” NOTE: Starter and Fault contactor 11” 16.75” 7.13” Height 5.63” 7.13” Width can extend up to 1/4” beyond the width of the mounting panel. Transformer (208/230/460 Volt) The Siemens/Nordic elevator starter requires 120VAC control power to operate. A control transformer with primary voltages of 208/230/460 is available. Order part #B075MBT713XK. ACCESS Elevator Supply FAX 510-652-5043 SIEMENS/NORDIC STARTER DIMENSIONS Elevator Starter Dimensions Ventilated Starter Enclosure The Siemens/Nordic elevator starter is also available in a NEMA 1 ventilated enclosure. Catalog Number 49EB217898 800-266-8654 Height 24.5” Width 18” Depth 12.5” 33 Door Reversing Contactors S TA R T E R S & C O N TA C TO R S D O O R R E V E R S I N G A275KXX91 A575KXX90 Door Reversing Contactor Application Guide C O N TA C TO R S 200V HP 230V HP 460V HP 1-1/2 3 1-1/2 3 2 5 -5 3 5 2 2 5 2 3 5 Max Motor Amps 5 7.5 10 3 7-1/2 ∗ ∗∗ 34 MFG Catalog Number 9 18 Aromat Aromat FCRM18-AC * FCRM20-AC * 9.6 17.5 Struthers-Dunn Struthers-Dunn A275KXX91 * A575KXX90 * 9 12 16 S+S S+S S+S CAU7-9-22 * CAU7-12-22 * CAU7-16-22 * Standard Height Width Aux Contacts (inches) (inches) (NO - NC) 2 4 2 2 2 2 4 2.9 2.9 2 2 2 4 Form C 2 Form C 3.2 3.2 3.2 To complete catalog number, please specify AC or DC coil voltage. 3.6 4.43 7.5 7.5 3.9 3.9 3.9 3 5.25 Depth (inches) 3.4 3.4 3.2 ** 3.2 ** 3.2 ** 2.75 3.0 S+S contactors with true DC coils are deeper. Call Access for dimensions. 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Door Reversing Contactors CONTACTORS Door Reversing Contactors (FCRM20) REVERSING FRCM18/20 DOOR (CAU7-12) CAU7-9/12/16 (AC coil shown) ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 35 DC Drive Contactors S TA R T E R S & C O N TA C TO R S D C D R I V E DC Drive Contactor Application Guide Current Rating in Amps C O N TA C TO R S 130 220 280 360 30 60 120 180 260 40 75 110 180 260 360 MFG ABB ABB ABB ABB EHDB130C-1L * EHDB220C-1L * EHDB280C-1L * EHDB360C-1L * Joslyn-Clark Joslyn-Clark Joslyn-Clark Joslyn-Clark Joslyn-Clark Joslyn-Clark 7001-7140 * 5DP7-7140 * 5DP3A-5091 * 5DP4-5091 * 5DP9-5091 * 5DP5-5091 * Mitsubishi Mitsubishi Mitsubishi Mitsubishi Mitsubishi ∗ 36 Catalog Number DU-A30 * DU-A60 * DU-A120 * DU-A180 * DU-A260 * Standard Aux Contacts (NO - NC) 1 1 1 1 2 2 2 2 2 0 0 0 0 0 0 1 1 1 1 2 2 2 2 2 0 0 0 0 0 0 Height Width Depth 5.5 6.3 6.3 6.3 4.9 5.6 5.6 7.2 5.6 6.6 6.6 7 (inches) 4.6 5.7 6.3 8 9.5 4.5 4.5 4.5 7.3 10.4 12.3 (inches) 4 4.7 6.4 5.5 6.4 4.3 4.3 4.3 5.7 5.7 8.3 (inches) 4.2 5 6.4 6.9 7.7 6 6 6 7.1 7.1 9.5 To complete catalog number, please specify coil voltage when ordering. 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & DC Drive Contactors C O N TA C TO R S D RC IOV NE T A C C OT NO TA RC S TO R S DC Drive Contactors D C ABB EHDB130 Mitsubishi DU-A120 ACCESS Elevator Supply FAX 510-652-5043 Joslyn Clark 5DP3A-5091 800-266-8654 37 Siemens Overload Relays S TA R T E R S Siemens ESP 100 Solid State Overload Relays & C O N TA C TO R S Easy installation -- just run motor wires through overload relay * S I E M E N S (Suitable for panel mounting) Wide range dial-type amp adjustment Fast phase loss protection -- trips within 3 seconds O V E R L O A D Class 20 motor overload protection 48BSH3M20 R E L AY S Catalog Number Current Range in Amps 48ASB3M20 * .75 - 3 48BSH3M20 9 - 18 48BSK3M20 20 - 40 48BSM3M20 48ASA3M20 * 48ASD3M20 * 2.5 - 10 48ASF3M20 13-27 48ASE3M20 48ASG3M20 ∗ 38 .25 - 1 These small overload relays require terminal connections. 800-266-8654 Catalog Number 48BSF3M20 48BSJ3M20 48BSL3M20 48BSN3M20 FAX 510-652-5043 Current Range in Amps 13 - 27 22 - 45 30 - 60 45 - 90 57 - 115 67 - 135 81 - 162 ACCESS Elevator Supply Easily adjustable dial Includes phase loss protection Aromat Overload Relays Aromat Overload Relays (Suitable for panel mounting) R E L AY S C O N TA C TO R S Ambient temperature compensated Manual or Auto Reset Catalog Number Current Range in Amps * FT50A-22 18 - 25 FT50A-16 FT50A-28 12 - 18 24 - 34 FT50A-40 30 - 45 FT80A-22 18 - 25 FT50A-42 FT80A-28 FT80A-40 FT80A-42 38 - 56 30 - 45 38 - 56 48 - 68 FT85A-95 80 - 110 60 - 90 FT125A-100 80 - 120 FT190A-135 105 - 165 FT190A-105 FT190A-165 ∗ (shown with optional lug kit) 24 - 34 FT80A-54 FT80A-80 FT50A-22 80 - 130 FT125A-100 130 - 200 Additional sizes available. Call Access for details. ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 39 O V E R L O A D & A R O M AT S TA R T E R S Replacement Parts S TA R T E R S & C O N TA C TO R S Accessories & Replacement Parts R E P L A C E M E N T Coils Contact Kits ACCESS Elevator Supply PA R T S Aux Contacts ACCESS stocks a massive inventory of replacement parts, accessories, contact kits, coils, aux contacts and mechanical interlocks for all of the starters and contactors shown in this catalog. Refer to the parts index on opposite page (page 41). Mechanical Interlocks 40 800-266-8654 FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & Replacement Parts C O N TA C TO R S ACCESSORIES & REPLACEMENT PARTS INDEX PA R T S Aromat . . . . . . . . . . . . . . . . . . . . . . Page 42 ABB . . . . . . . . . . . . . . . . . . . . . . . . . 43 GE . . . . . . . . . . . . . . . . . . . . . . . 44-45 Mitsubishi . . . . . . . . . . . . . . . . . . . . Siemens IEC . . . . . . . . . . . . . . . . . . R E P L A C E M E N T Joslyn-Clark . . . . . . . . . . . . . . . . . . . 46 47 48 Siemens NEMA (Furnas) . . . . . . . . . . 49 Westinghouse (Cutler-Hammer) . . . . . 51 Sprecher+Schuh . . . . . . . . . . . . . . . . 50 Contact Kits ....... For our full-color contact kit catalog, call Access today, 1 (800) 266-8654. ACCESS Elevator Supply FAX 510-652-5043 800-266-8654 41 Aromat Replacement Parts S TA R T E R S Aromat & C O N TA C TO R S Coils Accessories & Replacement Parts A R O M AT Contact Kits (BM6-85-901) Catalog # Size BM6-20-99 0+ 3 BM6-35-901 1++ 3 BM6-65-901 2++ 3 BM6-85-901 3+ 3 4+ 3 R E P L A C E M E N T BM6-18-95 BM6-25-99 BM6-50-901 BM6-80-901 0 1 2+ 3 BM6-125-901 3++ BM6-190-901 4++ BM6-160-901 Poles/Kit Catalog # 3 BM6-18-AC*V 3 BM6-50-AC*V 3 3 3 3 PA R T S Aux Contacts F/FC20 -- F/FC25 BM6-85-AC*V F/FC65 -- F/FC125 BM6-190-AC*V ∗ 1 NO / 1 NC -- for use w/F125 contactors & starters 42 1 NO / 1 NC -- for use w/F160/F190 contactors & starters 800-266-8654 F/FC35 -- F/FC50 F/FC160 -- F/FC190 To complete catalog number, please specify AC coil voltage. Mechanical Interlocks (A) BM6-190-63 F/FC15 -- F/FC18 BM6-25-AC*V Catalog Number BM6-125-63 For Contactor / Starter A) BM6-50-77 B) BM6-85-77 C) BM6-190-77 FAX 510-652-5043 (B) (C) For Interlocked/Reversing Contactor / Starter FRM/FCRM35/50 FRM/FCRM65/125 FRM/FCRM160/190 ACCESS Elevator Supply S TA R T E R S & ABB Replacement Parts C O N TA C TO R S ABB Accessories & Replacement Parts Contact Kits PA R T S Coils (EHDBCK110-2) EHDBCK110-2 EHDBCK110-NC EHDBCK130-2 EHDBCK130-NC EHDBCK220-2 EHDBCK220-NC EHDBCK280-2 EHDBCK280-NC EHDBCK360-2 EHDBCK360-NC Poles / Type 2 / NO 1 / NC 2 / NO 1 / NC Catalog # 2 / NO 1 / NC EHDBRC110- * EHDBRC130- * 2 / NO 1 / NC EHDBRC280- * EHDBRC360- * 2 / NO 1 / NC ∗ R E P L A C E M E N T Catalog # Contactor # EHDB110 EHDB130 EHDB220-280 EHDB360 To complete catalog number, please specify AC or DC coil voltage. Catalog Number CAL16-11A CAL16-11B CAL16-11C CAL16-11D Terminal Markings NO NC 13, 14 21, 22 53, 54 61, 62 43, 44 83, 84 71, 72 Right 35, 36 CAL16-11M 43, 44 31, 32 CAL16-11P ACCESS Elevator Supply 13, 14 43, 44 Left Right 47, 48 CAL16-11L Mounting Side 31, 32 CAL16-11E 21, 22 31, 32 FAX 510-652-5043 A B B 1 NO / 1 NC Aux Contacts Left Right Late Break (EHDB130) Left Positively Guided (EHDB220-280) Right Positively Guided (EHDB130) Right 800-266-8654 Positively Guided 43 GE Replacement Parts S TA R T E R S & C O N TA C TO R S GE Accessories & Replacement Parts Contact Kits -- 3-Pole G E R E P L A C E M E N T (V31108CA) Catalog # Product Line Size V31206B C2000 48A V31208B C2000 68A V31207B V31209B V31210B V31175CA V31108CA V31109BA 62A C2000 80A C2000 96A C2000 C2000 140A C2000 192A 156A C2000 PA R T S CR7XDG Spectra 700 CR7XDJ Spectra 700 CR7XDH CR7XDK CA5F2CPR1 CA5F3CPR1 Spectra 700 Spectra 700 Spectra CA5F Spectra CA5F 37A 45A 56A 73A 105A 140A (55-153678G002) Catalog # 00 546A300G002 100/200/300 55-152313G208 546A300G010 546A301G002 546A301G053 546A780G002 546A780G051 55-153677G002 55-153678G002 55-154607G002 55-154607G041 55-186556G002 55-186556G004 232A6724G006 101X111 101X112 101X113 6960067G001 6960049G001 800-266-8654 100/200/300 100/200/300 101X110 44 Size 55-152313G009 232A6724G009 (CA5F3CPR1) Product Line FAX 510-652-5043 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 100/200/300 CR7006 CR7006 CR7006 CR7006 CR7006 CR7006 00 0 0 1 1 2 2 3 4 5 5 6 6 6 6 0 1 2 3 4 5 ACCESS Elevator Supply GE Replacement Parts C O N TA C TO R S GE Coils Catalog # 15D21G * 15D22G * 55-501336G * 55-501463G * 55-501493G * 55-530249G * LB1A * LB3A * LB4A * Size 00-1 Accessories & Replacement Parts Type 100/200/300 Line 2 100/200/300 Line 4 100/200/300 Line 3 5 5 100/200/300 Line 200 Line 300 Line CL00/01/02/25 CL04/45 CL06/07/08/09/10 C2000 C2000 C2000 To complete catalog number, ∗ please specify AC coil voltage. Mechanical Interlocks Aux Contacts 200/300 Line (Base Block) Catalog # CR305X100A CR305X100B CR305X100C CR305X200A CR305X200B CR305X200C CR305X300A CR305X300B CR305X300C CR305X500A CR305X500B CR305X500C CR305X100D CR305X100E NEMA Size Contacts 00-1 1NO 0-1 1NC 0-1 1NO/1NC 2 2 2 1NO 1NC 3-4 3-4 3-4 5-6 5-6 5-6 0-6 0-6 1NO/1NC 1NO 1NC 1NO/1NC 1NO 1NC 1NO/1NC (Adder Block) Design mounts to: Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base Contactor base 1NO Existing aux cont block 1NC Existing aux cont block Aux Contacts -- C2000 Line G E (Side mount adder block) PA R T S & R E P L A C E M E N T S TA R T E R S Catalog # CR309X100B CR309X200D CR309X300B BEL02 ** BEKH ** ∗∗ Size Type 00-1 100/200/300 Line 3-4 100/200/300 Line 2 All All 100/200/300 Line C2000 Type CL C2000 Type CK These mechanical interlocks include two (2) built-in NC aux contacts ACCESS Elevator Supply FAX 510-652-5043 (Side mount base block) Catalog # BCLL11 BCLL20 BRLL11 BRLL20 BCLF10 BCLF01 Contacts 1NO/1NC 2NO 1NO/1NC 2NO 1NO 1NC 800-266-8654 (Front mount block) Design mounting type: Side mount base block Side mount base block Side mount adder block Side mount adder block Front mount block Front mount block 45 Joslyn Clark Replacement Parts S TA R T E R S Joslyn Clark for Aux Contacts J O S LY N (KTM-10) C L A R K Type Catalog # 1NC KTM-10 or 1NC 5M63 1NO 5M65 1NO/1NC 5M64 Type 1NO PA R T S 1-Pole Contact Kits for DC Contactors Type 5DP/7400 (KTM32-1) Catalog # Size CY 32-1 2 CY 34-1 4 CY 31-1 Catalog # Amp Rating 5M53 110 5M54 180 5M48 75 5M80A 5M56 5M49 46 Type Contactor NO 5DP3 56 NO 110 NO 5DP3A NO 5DP9 260 100/180/260 NO NC NC 5DP2 KHP32-1 Size 5 00-1 KTM32-1 1P, 2 KTM34-1 4 KTM33-1 2 KTM35-1 3 5 1-Pole Contact Kit AC Contactor Type 5003A/B (5M80) Catalog # 5DP7 5M80 800-266-8654 KTM31-1 00-1 5DP4 5DP3/4/9 KTM25-1 3 KHP31-1 for Catalog # 1 CY 33-1 (5M52) 5M52 AC Contactors for Type TM Size 00-4 AC Contactors (5M65) Catalog # C O N TA C TO R S 3-Pole Contact Kits Accessories & Replacement Parts for Type 5DP DC Drive Contactors & FAX 510-652-5043 Amp Rating 100 Contactor 5003A/B ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Mitsubishi Replacement Parts Mitsubishi Accessories & Replacement Parts 3-Pole Contact Kits PA R T S AC Contactors Catalog Number DU-A30COIL-AC * DU-A60COIL-AC * (BH559N300) Catalog # BH509N301 BH509N304 BH519N304 BH529N301 Size BH569N300 2.75 00 BH569N302 2.75 BH579N301 3.5 BH589N300 4 00 0 .75 BH549N301 1.5 BH559N301 2.5 BH559N303 2.5 BH559N300 BH559N302 BH559N306 BH559N307 Size 00 BH539N300 BH549N300 Catalog # 1 2 2 1.5 2 ACCESS Elevator Supply BH569N301 BH569N303 BH579N304 BH599N300 3 3 3.5 4.5 BH599N301 4.5 BH609N301 5.5 BH619N301 7 BH609N300 BH619N300 5 6 FAX 510-652-5043 DU-A120COIL-AC * DU-A180COIL-AC * DU-A260COIL-AC * Contact Kits ∗ To complete catalog number, please specify AC or DC coil voltage. (Z939402G10) for DC Drive Contactors Catalog # Poles Contactor Z939400G10 Z939401G10 Z939402G10 2 NO/1NC 2 NO/1NC 2 NO/1NC DU-A30 DU-A60 DU-A120 BH609N308 BH609N309 2 NO 1 NC DU-K260 DU-K260 BH599N308 BH599N309 800-266-8654 2 NO 1 NC DU-K180 DU-K180 47 M I T S U B I S H I for Coils for DC Drive Contactors Siemens IEC Replacement Parts S TA R T E R S Siemens IEC 3-Pole Contact Kits Accessories & Replacement Parts S I E M E N S Aux Contacts (3RT1945-6A) Catalog # 3TY6440-OA Size I E C PA R T S 3RH1921-1FA40 3RH1921-1FA31 3RH1921-1FA22 3RH1921-1FA04 3RH1921-1CA10 3RH1921-1CA01 3RH1921-1LA11 3RH1921-1LA20 3RH1921-1LA02 3RH1921-1EA20 3RH1921-1EA11 3RH1921-1EA02 3RH1921-1KA20 3RH1921-1KA11 3RH1921-1KA02 ∗ Size 3-12 only 4NO 3NO/1NC 2NO/1NC 4NC 1NO 1NC 1NO/1NC 2NO 2NC 2NO 1NO/1NC 2NC 2NO 1NO/1NC 2NC Mounting/Position Catalog # 3RT1935-6A 2.5 3TY6500-OA 3.5 3TY6540-OA 4.5 3 3TY6560-OA 3TY6580-OA/OB 6 3TY7440-OA 0-1 3TY7460-OA 2 3TY7450-OA 1.5 3TY7470-OA 2.5 3TY7490-OA 3 3TY7480-OA 3 Coils Contactor 2/32 3RT1936-6A 2/50 3RT1945-6A 25-106-921-812 4 Catalog # 3RT1035/36 3RT1965-5A*31 800-266-8654 ∗ 1 25-106-924-812 25-106-923-812 3RT1935-5A*01 3RT1044 3/80 2 3RT1945-5A*01 3RT1944-5A*01 2/40 25-106-922-812 3RT1023/24/25/26 3RT1033/34 3.5 4 4 4.5 5 6 3RT1934-6A 3RT1924-5A*01 3RT1934-5A*01 48 5 3TY6470-OA 3TY6520-OA Front Front Front Front Front Front Front Front Front Side/Inside Side/Inside Side/Inside Side/Outside * Side/Outside * Side/Outside * 4 2 3TY6480-OA Size/Amps Catalog # 3TY7500-OA 3TY7510-OA 3TY7520-OA/OB 3TY7540-OA/OB 3TY7560-OA/OB 3TY7580-OA/OB 1 3TY6460-OA Contacts C O N TA C TO R S (3TY6480-OA) Size 0-12 Catalog # & 3 Contactor 3RT1045/46 3RT1955-5A*31 3RT1054/55/56 3RT1975-5A*31 3RT1075/76 3RT1064/65/66 To complete catalog number, please specify coil voltage. FAX 510-652-5043 ACCESS Elevator Supply S TA R T E R S & Siemens NEMA Replacement Parts C O N TA C TO R S Siemens NEMA (Furnas) (75FP14) Accessories & Replacement Parts 1-Pole Contact Kits 25A 75BE42 75BF14 75CA14 75CC16 25A 75FF14 30A 75FP109153 00 0 0 75CE42 40A 75DA14 1 75CF14 0 75DE42 50A 75EA14 1.75 75DF14 75ED42 1 60A 75EE42 60A 75EF42 60A 75FE42 75A 75EF14 75FB14A 1.75 2 Size 2 75FF15 F 75FP14 2 75GB14 2 2.5 75GE42 90A 75GF15 G 75GF14 2.5 75GP14 2.5 75HF14 3 75HB14 75HF15 3 H 75IB14 3.5 75JB14 4 75IF14 75JG14 75RB14 75KB14 NEMA Aux Contacts Size 00-4 Catalog # 49AB10 49AB01 49AB11 49AB20 49AB40 49AB31 49AB22 Contacts 1NO 1NC 1NO/1NC 2NO 4NO 3NO/1NC 2NO/2NC Siemens NEMA Coils 3.5 4 Catalog # NEMA Size 5 75D73251 * 3 - 3-1/2 4.5 75D73070 * 75D70131 * ∗ ACCESS Elevator Supply 0-1 1-3/4 2 - 2-1/2 3 - 3-1/2 4 FAX 510-652-5043 800-266-8654 PA R T S 75AF42 75NB41 Catalog # 49CCF22HP 49EEF22HP 49GGF22HP 49HHP22HP 49JJG22HP Size N E M A Size Catalog # 0 - 2-1/2 4 To complete catalog number, please specify coil voltage. 49 S I E M E N S Catalog # Mechanical Interlocks Sprecher+Schuh Parts S TA R T E R S Sprecher+Schuh -- Division of Rockwell Automation -- Accessories & Replacement Parts Mechanical Interlocks Catalog # S P R E C H E R + S C H U H CM3 CM7 CM7-02 CM6 CM6-D00 CM6-D02 Aux Contacts none none 2NC none none 2NC Contactor CA3 CA7 CA7 CA6 CA6 CA6 3-Pole Contact Kits (22.801.200-01) Catalog # PA R T S 22.102.217-03 22.109.212-02 22.110.212-02 22.114.212-02 22.104.212-04 22.104.212-06 22.105.212-03 22.701.214-01 22.701.215-01 22.701.216-01 22.701.217-01 22.801.200-01 22.801.201-01 22.801.206-01 22.802.200-01 22.802.201-01 22.802.206-01 22.805.201-01 22.805.202-01 50 Size 00, 0 1, 1.75 2 2.5 3, 3.5 4 4.5 1 2 2 2.5 3 3.5 3.5 4 4.5 4 4.75 5 Contactor CA1-10 CA1-16 CA1-25 CA1-40 CA1-55/60 CA1-100 CA1-150 CA3-37 CA3-43 CA3-60 CA3-72 CA6-85/95 CA6-105/110 CA6-105E/110E CA6-140E CA6-170E/180E CA6-140 CA6-210E CA6-250E 800-266-8654 Catalog # 22.110.206-* 22.104.340-* 22.122.304-* 22.601.304-* 22.701.323-* 22.501.304-* 22.601.305-* 22.701.324-* 22.801.314-* CA6-TG * & C O N TA C TO R S Coils Contactor CA1-25 CA1-55/60/100 CA3-9/12/16 CA3-23/30 CA3-37/43/60/72 CA3-9C/12C/16C CA3-23/30 CA3-37/43/60/72 CA6-85/105 Coil Type AC AC AC AC AC DC DC DC AC CA6-95/110/140/180 AC&DC ∗ To complete catalog number, please specify coil voltage. Aux Contacts Catalog # CS7-PV-02 CS7-PV-11 CS7-PV-20 CS7-PV-22 CS7-PV-31 CS7-PV-13 CS7-PV-40 CS7-PV-04 CA7-PA-01 CA7-PA-10 CA7-PA-02 CA7-PA-11 CA7-PA-20 CA6-S1-11 CA6-S2-11 CA6-S1-20 CA6-S2-20 CA6-S1-B11 Contacts 2NC 1NO/1NC 2NO 2NO/2NC 3NO/1NC 1NO/3NC 4NO 4NC 1NC 1NO 2NC 1NO/1NC 2NO 1NO/1NC 1NO/1NC 2NO 2NO Form C FAX 510-652-5043 Mounting/Position Top Top Top Top Top Top Top Top Side Side Side Side Side Side/Inside Side/Outside Side/Inside Side/Outside Side/Inside ACCESS Elevator Supply S TA R T E R S & C O N TA C TO R S Westinghouse Replacement Parts Westinghouse (now Cutler-Hammer) Catalog # 373B331G18 373B331G04 373B331G09 373B331G12 672B788G09 626B187G13 5250C81G17 626B187G17 477B477G05 477B477G06 Size 00 0 1 2 2.5 3 4 4 5 5 Poles/Kit 4 4 4 3 3 3 3 3 1 1 Coils Catalog # 505C806G * 505C806G * 505C633G * 5250C79G * 2050A14G * 2050A12G * ∗ J11 J20 J02 00-1 2 3-4/J 4/K 5 6 please specify coil voltage. FAX 510-652-5043 L-56E/P/S L-56D/B/H L-56C/R Contacts 1NO/1NC 2NO 2NC 3-Pole Contact Kits 1605226 1605212 1605202 Size / Model Old Cat. # Type N / Lifeline Catalog # To complete catalog number, ACCESS Elevator Supply Catalog # (1625563) Size 0 1 2 Catalog # 1625563 1625564 1620146 Size 3 4 5 B200 3-Pole Contact Kits (B200-2) Catalog # B200-1 800-266-8654 Size 1 Catalog # B200-2 Size 2 51 PA R T S (626B187G13) Aux Contacts W E S T I N G H O U S E A200 Contact Kits Accessories & Replacement Parts Part Number Index S TA R T E R S Part Number Index OEM Number 100-B110N*3 Page 11 101X110 44 101X112 44 101X111 PA R T 101X113 14CSD32A 44 44 18 N U M B E R 14CSE32A 18 14DSF32A 18 14DSE32A 14ESF32A 14ESG32A 14FSF32A 14FSH32A I N D E X 14GSH32A 14GSJ32A 18 18 18 18 18 18 18 14HSJ32A 18 14ISL32A 18 15D21G 45 1605202 51 1605226 51 14HSK32A 14JTM32A 15D22G 1605212 1620146 52 18 18 45 51 51 (100-B110N OEM Number 1625563 1625564 2050A12G 2050A14G 51 51 51 51 50 22.104.212-06 50 22.105.212-03 50 22.110.206 50 22.114.212-02 50 22.104.340- 22.109.212-02 22.110.212-02 50 50 50 50 22.122.304 50 22.601.304 50 22.501.304 22.601.305 22.701.324 22.801.314 22.701.214-01 22.701.215-01 50 50 50 50 50 50 22.701.216-01 50 22.701.323 50 22.701.217-01 22.801.200-01 800-266-8654 C O N TA C TO R S 3RT1036) Page 22.102.217-03 22.104.212-04 thru & 50 50 FAX 510-652-5043 OEM Number 22.801.201-01 22.801.206-01 22.802.200-01 22.802.201-01 Page 50 50 50 50 22.802.206-01 50 22.805.202-01 50 22.805.201-01 25-106-921-812 25-106-922-812 25-106-923-812 25-106-924-812 232A6724G006 232A6724G009 373B331G04 50 48 48 48 48 44 44 51 373B331G09 51 373B331G18 51 373B331G12 3RH1921-1CA01 3RH1921-1CA10 51 48 48 3RH1921-1EA02 48 3RH1921-1EA20 48 3RH1921-1EA11 3RH1921-1FA22 3RH1921-1FA31 3RH1921-1FA40 48 48 48 48 ACCESS Elevator Supply Part Number Index C O N TA C TO R S 3RH1921-1FA04 3RH1921-1LA02 3RH1921-1LA11 3RH1921-1LA20 3RH1921-1KA20 3RH1921-1KA11 Page 48 48 48 48 48 48 3RH1921-1KA02 48 3RT1016 (str) 19 3RT1016 (con) 3RT1023 (con) 10 19 3RT1024 (str) 19 10 3RT1025 (con) 10 3RT1026 (con) 10 3RT1033 (con) 10 3RT1034 (con) 10 3RT1035 (con) 10 3RT1036 (con) 10 3RT1025 (str) 3RT1026 (str) 3RT1033 (str) 3RT1034 (str) 3RT1035 (str) 3RT1036 (str) ACCESS Elevator Supply Starters 10 3RT1023 (str) 3RT1024 (con) I N D E X OEM Number PART NUMBER INDEX N U M B E R & 19 19 PA R T S TA R T E R S Contactors 19 19 Overload Relays 19 19 FAX 510-652-5043 800-266-8654 53 Part Number Index S TA R T E R S Part Number Index OEM Number 3RT1044 (con) 3RT1044 (str) Page OEM Number 19 3RT1944-5A 48 3TY7510-OA 10 PA R T N U M B E R 3RT1046 (con) 10 3RT1054 (con) 10 3RT1054 (str) 19 3RT1054* 19 19 11 I N D E X 3RT1055 (con) 10 3RT1056 (con) 10 3RT1064 (con) 10 3RT1065 (con) 10 3RT1066 (con) 10 3RT1075 (con) 10 3RT1076 (con) 10 3RT1924-5A 48 3RT1055 (str) 3RT1056 (str) 3RT1064 (str) 3RT1065 (str) 3RT1066 (str) 3RT1075 (str) 3RT1076 (str) 3RT1934-5A 54 42HF35A) OEM Number 10 3RT1046 (str) thru C O N TA C TO R S Page 3RT1045 (con) 3RT1045 (str) (3RT1044 & 19 19 19 19 19 19 19 48 3RT1935-5A 48 3RT1934-6A 48 3RT1935-6A 48 3RT1936-6A 48 3RT1945-5A 48 3RT1955-5A 48 3RT1945-6A 48 3RT1965-5A 48 3RT1975-5A 48 3TY6440-OA 48 3TY6460-OA 48 3TY6470-OA 48 3TY6480-OA 48 3TY6500-OA 48 3TY6540-OA 48 3TY6520-OA 48 3TY6560-OA 48 3TY6580-OA 48 3TY7440-OA 48 3TY7460-OA 48 3TY7450-OA 3TY7470-OA 48 3TY74800-OA 3TY7490-OA 800-266-8654 48 48 48 3TY7500-OA 3TY7520-OA/OB 3TY7540-OA/OB 3TY7560-OA/OB 3TY7580-OA/OB 40CP32A 40DP32A Page 48 48 48 48 48 48 8 8 40EP32A 8 40GP32A 8 40FP32A 40HP32A 40IP32A 40JG32A 41NB20AFM 8 8 8 8 9 41NB21AFM 9 42AF35A 9 41NB30AFM 42BF35A 9 9 42CF35A 9 42EF35A 9 42GE35A*106 9 42DF35A 42FE35A*106 42HF35A FAX 510-652-5043 9 9 9 ACCESS Elevator Supply Part Number Index Part Number Index OEM Number 42IF35A*106 42EG20 Page OEM Number Page 9 49GGF22HP 49 9 477B477G05 51 48ASA3M20 38 477B477G06 48ASB3M20 48ASD3M20 48ASE3M20 48ASF3M20 48ASG3M20 51 38 38 38 38 38 48BSF3M20 38 48BSJ3M20 38 48BSH3M20 48BSK3M20 48BSL3M20 48BSM3M20 48BSN3M20 49AB10 49AB01 49AB11 49AB20 49AB40 49AB31 49AB22 49CCF22HP ACCESS Elevator Supply (42IF35A 38 38 38 38 38 49 49 49 49 49 49 49 49 49EEF22HP 49 49HHP22HP 49 505C633G 51 5250C79G 51 49JJG22HP 505C806G 5250C81G17 5DP7-7140 5DP3A-5091 5DP4-5091 49 51 51 36 36 36 5DP9-5091 36 5M48 46 5DP5-5091 5M49 36 46 5M52 46 5M53 46 5M56 46 5M54 46 5M63 46 5M64 46 5M65 46 5M80 5M80A 46 546A300G002 FAX 510-652-5043 thru 46 44 800-266-8654 75AF42) OEM Number 546A300G010 546A301G002 546A301G053 546A780G002 546A780G051 55-152313G009 55-152313G208 55-153677G002 Page 44 44 44 44 44 44 44 44 55-153678G002 44 55-154607G041 44 55-154607G002 55-186556G002 55-186556G004 55-501336G 55-501463G 55-501493G 55-530249G 44 44 44 45 45 45 45 626B187G13 51 6960049G001 44 626B187G17 6960067G001 672B788G09 7001-7140 72 Soft Start 75AF42 51 44 51 36 30 49 55 I N D E X C O N TA C TO R S N U M B E R & PA R T S TA R T E R S Part Number Index S TA R T E R S Part Number Index OEM Number 75BE42 75BF14 75CA14 PA R T 75CC16 75CE42 75CF14 Page 49 49 49 49 49 49 N U M B E R 75D70131 49 75D73251 49 75DE42 49 75D73070 75DA14 75DF14 75EA14 I N D E X 75ED42 75EE42 75EF14 75EF42 75FB14A 75FE42 75FF14 75FF15 49 49 49 49 49 49 49 49 49 49 49 49 75FP109153 49 75GB14 49 75FP14 75GE42 56 49 49 (75BE42 OEM Number 75GF14 75GF15 75GP14 75HB14 Page 49 BH509N304 47 49 49 49 75IB14 49 75JB14 49 75JG14 75NB41 49 49 49 49 75RB14 49 A275KXX91 34 75KB14 49 A575KXX90 34 B200-2 51 B200-1 51 BCLL11 45 BRLL11 45 BCLL20 45 BRLL20 45 BCLF10 45 BCLF01 BEL02 BEKH 800-266-8654 BH609N300) OEM Number 49 75IF14 C O N TA C TO R S Page 75HF14 75HF15 thru & 45 45 45 BH509N301 BH519N304 BH529N301 BH539N300 BH549N300 47 47 47 47 47 BH549N301 47 BH559N301 47 BH559N303 47 BH559N300 BH559N302 BH559N306 BH559N307 BH599N308 BH599N309 47 47 47 47 47 47 BH569N300 47 BH569N302 47 BH569N301 BH569N303 47 47 BH579N301 47 BH589N300 47 BH599N301 47 BH579N304 BH599N300 BH609N300 FAX 510-652-5043 47 47 47 ACCESS Elevator Supply Part Number Index Part Number Index OEM Number Page BH609N308 47 BH609N301 BH609N309 BH619N300 BH619N301 47 47 47 47 BM6-18-95 42 BM6-20-99 42 BM6-18-AC 42 BM6-25-99 42 BM6-35-901 42 BM6-25-AC BM6-50-901 BM6-50-AC BM6-50-77 BM6-65-901 42 42 42 42 42 BM6-80-901 42 BM6-85-77 42 BM6-125-63 42 BM6-160-901 42 BM6-190-901 42 BM6-85-901 BM6-85-AC BM6-125-901 BM6-190-63 BM6-190-AC ACCESS Elevator Supply 42 42 42 42 42 (BH609N301 thru CA7-60-10) Page OEM Number Page CA6-140 50 CA7-PA-02 50 CA5F2CPR1 44 OEM Number BM6-190-77 CA6-180 CA5F3CPR1 CA6-95 CA6-110 42 50 44 7 7 CA6-140 7 CA6-180 7 CA6-S1-11 50 CA6-S1-20 50 CA6-S2-11 CA6-S2-20 CA6-S1-B11 CA6-TG CA7-9-10 CA7-12-10 50 50 7 7 CA7-43-10 7 CA7-72-10 7 FAX 510-652-5043 7 7 7 7 800-266-8654 50 50 50 50 CAL16-11A 43 CAL16-11C 43 CAL16-11B CAL16-11D 43 43 CAL16-11E 43 CAL16-11M 43 CAL16-11P 7 CA7-85-10 CA7-PA-20 50 CA7-30-10 CA7-60-10 CA7-PA-11 CAL16-11L 7 CA7-37-10 CA7-PA-10 50 CA7-16-10 CA7-23-10 CA7-PA-01 43 43 CAT6-95 17 CAT6-140-EL 17 CAT6-110 CAT6-180-EL CAT7-9-10 CAT7-12-10 17 17 17 17 CAT7-16-10 17 CAT7-30-10 17 CAT7-43-10 17 CAT7-23-10 CAT7-37-10 CAT7-60-10 17 17 17 57 I N D E X C O N TA C TO R S N U M B E R & PA R T S TA R T E R S Part Number Index S TA R T E R S Part Number Index OEM Number Page OEM Number CAT7-85-10 17 CAUT7-23-22 CAT7-72-10 CAU6-95 PA R T CAU6-110 CAU6-140-EI CAU6-180-EI 17 25 25 25 25 N U M B E R CAU7-9-22 25 CAU7-12-22 25 CAU7-16-22 25 CAU7-9-22 CAU7-12-22 CAU7-16-22 CAU7-23-22 I N D E X CAU7-30-22 CAU7-37-22 CAU7-43-22 CAU7-60-22 35 35 35 25 25 25 25 25 CAU7-72-22 25 CAUT6-95 29 CAU7-85-22 25 CAUT6-110 29 CAUT6-180-EI 29 CAUT6-140-EI CAUT7-9-22 CAUT7-12-22 58 29 29 29 (CAT7-72 Page CAUT7-16-22 29 CAUT7-30-22 12 CK75CE311 (con) 12 29 29 12 CL00A310T (str) 21 CL01A310T (str) 21 CL02A310T (str) 21 CL02A310T (con) 12 21 12 CL45A310T (str) 21 CL06A310T (str) 21 CL06A310T (con) 12 CL07A310T (con) 12 CL08A310T (con) 12 CL07A310T (str) 800-266-8654 21 21 21 CK08CE311 (str) 21 CK08CE311 (con) 12 CK09BE311 (con) 12 CK95BE311 (con) 12 CK95BE311 (str) 21 21 CK75CE311 (str) 12 CL04A320T (con) CL45A310T (con) CL10A310T (str) CK09BE311 (str) 12 CL04A320T (str) CL09A310T (str) 12 CL25A310T (con) CL25A310T (str) 21 CL10A310T (con) CAUT7-72-22 CL01A310T (con) CL08A310T (str) Page 29 29 CL00A310T (con) OEM Number 12 29 CAUT7-85-22 CR305X) CL09A310T (con) CAUT7-43-22 CAUT7-60-22 C O N TA C TO R S 29 29 CAUT7-37-22 thru & CK10CE311 (con) CK10CE311 (str) CK11CE311 (con) CK11CE311 (str) 21 21 12 21 12 21 CM3 50 CM6-D00 50 CM6 50 CM6-D02 50 CM7-02 50 CR305X100B 45 CM7 CR305X100A FAX 510-652-5043 50 45 ACCESS Elevator Supply Part Number Index Part Number Index OEM Number CR305X100C CR305X100D CR305X100E CR305X200A CR305X200B CR305X200C CR305X300A Page 45 45 45 45 45 45 45 CR305X300B 45 CR305X500A 45 CR305X300C 45 CR305X500B 45 CR306A00 20 CR305X500C 45 CR306B00 20 CR306D00 20 CR306F00 20 CR306C00 CR306E00 CR306G00 CR309X100B CR309X200D 20 20 20 45 45 CR309X300B 45 CR7XDH 44 CR7XDG CR7XDJ ACCESS Elevator Supply 44 44 (CR305X OEM Number CR7XDK CS7-PV-02 CS7-PV-11 CS7-PV-20 Page EHDB280C-1L 36 EHDBCK110-2 43 50 50 CS7-PA-01 CS7-PV-10 50 50 50 50 50 CY31-1 46 CY33-1 46 CY32-1 46 CY34-1 46 DU-A30COIL 47 DU-A60COIL 47 DU-A30 DU-A60 36 36 DU-A120 36 DU-A180 36 DU-A120COIL 47 DU-A180COIL 47 DU-A260COIL 47 DU-A260 FAX 510-652-5043 Page 50 50 CS7-PV-13 CS7-PV-04 OEM Number EHDB130C-1L 50 CS7-PV-40 FC50-AC) 44 CS7-PV-22 CS7-PV-31 thru 36 800-266-8654 EHDB220C-1L EHDB360C-1L 36 36 36 EHDBCK110-NC 43 EHDBCK130-NC 43 EHDBCK130-2 EHDBCK220-2 EHDBCK220-NC EHDBCK280-2 EHDBCK280-NC 43 43 43 43 43 EHDBCK360-2 43 EHDBRC110 43 EHDBCK360-NC EHDBRC130 EHDBRC280 43 43 43 EHDBRC360 43 F20-AC 16 F25-AC 16 F35-AC 16 FC20-AC FC25-AC FC35-AC FC50-AC 6 6 6 6 59 I N D E X C O N TA C TO R S N U M B E R & PA R T S TA R T E R S Part Number Index S TA R T E R S Part Number Index OEM Number F50-AC FC65-AC Page OEM Number Page 6 FRM50-AC 28 16 PA R T N U M B E R F65-AC 16 F80-AC 16 F85-AC 16 F125-AC 16 F160-AC 16 FCRM18-AC 34 FC80-AC FC85-AC FC125-AC FC160-AC FC190-AC 6 6 6 6 6 I N D E X FCRM20-AC 34 FCRM25-AC 24 FCRM20-AC FCRM35-AC FCRM50-AC 24 24 24 FCRM65-AC 24 FCRM85-AC 24 FCRM80-AC FCRM125-AC FCRM160-AC FCRM190-AC FRM20-AC FRM25-AC 60 (FC50-AC 24 24 24 24 28 28 FRM35-AC FRM65-AC FRM80-AC FRM85-AC FRM125-AC FRM160-AC FRM190-AC FT50A-16 FT50A-22 FT50A-28 FT50A-40 28 28 28 28 28 28 28 39 39 39 39 FT50A-42 39 FT80A-28 39 FT80A-22 FT80A-40 39 39 FT80A-42 39 FT80A-80 39 FT125A-100 39 FT80A-54 FT85A-95 39 39 FT190A-105 39 FT190A-165 39 FT190A-135 J02 800-266-8654 39 51 thru & C O N TA C TO R S Z939402) OEM Number J11 J20 KHP31-1 KHP32-1 KTM-10 KTM25-1 Page 51 51 46 46 46 46 KTM31-1 46 KTM33-1 46 KTM35-1 46 KTM32-1 KTM34-1 LB1A 46 46 45 LB3A 45 V31206B 44 LB4A V31207B 45 44 V31208B 44 V31210B 44 V31209B V31175CA V31108CA 44 44 44 V31109BA 44 Z939401G10 47 Z939400G10 Z939402G10 FAX 510-652-5043 47 47 ACCESS Elevator Supply