Contents Related catalogues Low-Voltage Controls and Distribution SIRIUS · SENTRON · SIVACON Order No.: Catalog E86060-K1002-A101-A7-7600 Technical Information incl. Low-Voltage Controls and Components for Applications according to UL Order no.: E86060-K1816-A101-A1-7600 Industrial Communication Industrial Communication for Automation and Drives Order No.: E86060-K6710-A101-B6-7600 E86060-K6710-A121-A2-7600 LV 1 LV 1 T LV 16 IK PI IK PI N Systems • Controlgear: Contactors and contactor assemblies, solid-state switching devices • Protection equipment • Load feeders, motor starters and soft starters • Monitoring and control devices • Detecting devices • Commanding and signaling devices • Transformers • Power supplies • Planning and configuration with SIRIUS • Power Management System • SIVACON Power, distribution boards, busway and cubicle systems • SENTRON switching and protection devices for power distribution • Air circuit breakers, molded case circuit breakers, switch disconnectors • Software for power distribution • BETA low-voltage circuit protection SIRIUS 3RV17 and 3RV18 circuit breakers according to UL 489 • SIVACON Components for 8US Distribution Systems according to UL 508A • SENTRON 3WL5 air circuit breakers/non-automatic air circuit breakers according to UL 489/IEC • SENTRON 3VL Molded Case Circuit Breakers according to UL 489/IEC • ALPHA Devices according to UL Standard • BETA Devices according to UL standard PROFINET/Industrial Ethernet • Industrial Mobile Communicaton • PROFIBUS to IEC 61158/EN 50170 • SIMATIC ET 200 distributed I/Os • AS-Interface to EN 50295/IEC 61158 • Remote operation with SINAUT Telecontrol • Routers • ECOFAST system LV 50 System cubicles • Cubicle modifications • Cubicle expansion components • Accessories • Special cubicles Cubicle solutions in applications • Cubicle air-conditioning • Special colors SIDAC Reactors and Filters Order No.: E86060-K2803-A101-A4-7600 LV 60 Commutating reactors for converters • Mains reactors for frequency converters • Iron-core output reactors • Ferrite output reactors • Iron-core smoothing reactors • Smoothing air-core reactors • Filter reactors • Application-specific reactors • Radio interference suppression filters • dv/dt filters • Sinewave filters SIVACON 8PS CD-K, BD01, BD2 Busbar Trunking Systems up to 1250 A Order No.: E86060-K1870-A101-A3-7600 LV 70 Busbar trunking systems, overview • CD-K system (25 A to 40 A) • BD01 system (40 A to 160 A) • BD2 system (160 A to 1250 A) Automation & Drives The A&D Offline Mall CD-ROM: E86060-D4001-A110-C6-7600 DVD: E86060-D4001-A510-C6-7600 CA 01 All Automation and Drives products, including those in the catalogs listed above. SICUBE System Cubicles and Cubicle Air-Conditioning Order No.: E86060-K1920-A101-A3-7600 A&D Mall Internet: http://www.siemens.com/automa tion/mall All Automation and Drives products, including those in the catalogs listed above. Catalog-PDF Internet: http://www.automation. siemens.com/cd All catalogs for low-voltage controls and distribution can be downloaded as PDF files. Registered trademarks All product designations may be registered trademarks or product names of Siemens AG or other supplying companies. Third parties using these trademarks or product names for their own purposes may infringe upon the rights of the trademark owners. Further information about low-voltage controls is available on the Internet at: http://www.siemens.com/lowvoltage Technical Assistance Expert technical assistance for Low-voltage controls and electrical installation. Tel.: +49 (9 11) 8 95-59 00 Fax: +49 (9 11) 8 95-59 07 E-Mail: technicalassistance@siemens.com sivacon S4 Power Distribution Boards Introduction 1 Power Distribution Boards 2 Standard Configurations 3 Cubicles, Supporting Structure and Enclosures 4 Busbar System 5 Assembly Kits for Switching Devices 6 Covers, Modular Doors, Mounting Plates, 19” Rack 7 Internal Separation 8 Air-conditioning Products 9 Catalogue LV 56 · 2008 The products listed in this catalogue are manufactured at production units working according to a quality system certified for conformity to EN 29001 (ISO 9001) Not valid: Catalogue LV 56 · 2006 Contact your local Siemens representative for further information © Siemens AG 2008 Accessories 10 Mechanical Dimensions 11 Planning and Configuration 12 Appendix 13 Explanations Information on catalogue LV 56 · 2008 and Manual SIVACON S4 · 2008 Catalogue LV 56 · 2008 contains the data relevant to selection and ordering. Additional information is given in SIVACON S4 Manual. Delivery class (DC)1) The delivery class indicates a product’s delivery time in working days from order receipt to product ready for dispatching from the warehouse. Price1) The stated price is in € and refers to the price per unit (PU). Price unit (PU) The price unit specifies to how many items (IT), sets (ST) or metres (M) the stated price and weight applies. Price group (PG)1) Each product is assigned to a price group. Dimensions All dimensions are expressed in mm. 1) Information is provided on a separate price list. 2 Siemens LV 56 · 2008 Total deliver time is given by the sum of order processing time in the country of origin, predetermined delivery time and transport time. 1 Introduction 1/2 Siemens Automation and Drives Welcome 1/4 Sharpen your competitive edge Totally Integrated Automation 1/6 Low-Voltage Power Distribution with SIVACON, SENTRON and SIMARIS Siemens LV 56 · 2008 Siemens Automation and Drives. Welcome More than 60,000 people aiming for the same goal: increasing your competitiveness. That's Siemens Automation and Drives. We offer you a comprehensive portfolio for sustained success in your sector, whether you’re talking automation engineering, drives or electrical installation systems. Totally Integrated Automation (TIA) and Totally Integrated Power (TIP) form the core of our offering. TIA and TIP are the basis of our integrated range of products and systems for the manufacturing and process industries as well as building automation. This portfolio is rounded off by innovative services over the entire life cycle of your plants. Learn for yourself the potential our products and systems offer. And discover how you can permanently increase your productivity with us. Your regional Siemens contact can provide more information. He or she will be glad to help. 1/2 Siemens LV 56 · 2008 Siemens LV 56 · 2008 1/3 Integrated energy distribution from a single source. Totally Integrated Power Totally Integrated Power (TIP) brings together all the components of electrical energy distribution into an integrated whole. Thus TIP provides the answer to growing market demands in the planning, construction and use of utility buildings and industrial buildings. On the basis of TIP, we offer integrated solutions for energy distribution, from medium voltage to the power outlet. Totally Integrated Power is based here on integration in planning and configuring as well as on perfectly matched products and systems. 1/4 1/4 Siemens LV 56 · 2008 Siemens IK PI · 2000 Totally Integrated Power offers communication and software modules for connecting the energy distribution systems to industrial automation and building automation. This enables the implementation of significant savings potential. Siemens LV 56 · 2008 1/5 Low-voltage power distribution with SIVACON, SENTRON and SIMARIS Non-residental buildings and industrial plants have one thing in common: without electricity, everything comes to a halt. The availability, safety and cost effectiveness of the power distribution system is of utmost importance – from the medium voltage supply point through to the socket outlet. And only integrated solutions can ensure maximum efficiency for planning, configuration and SIVACON power distribution boards operation. The concept is called Totally Integrated Power from Siemens. Total integration in planning and configuration creates synergies and saves costs. Perfectly matched products and systems provide efficient engineering and reliable operation. In the field of low-voltage power distribution, the following product ranges are available: SIVACON: From flexible busbar trunking systems through to safe power distribution boards and motor control centers. SENTRON: From well-proven switch disconnectors through to intelligent circuit breakers. SENTRON switching devices Software for power distribution: Everything for dimensioning, configuring, visualizing and controlling your power distribution. SIMARIS software for power distribution 1/6 Siemens LV 56 · 2008 2 SIVACON S4 Power Distribution Boards 2/2 Introduction 2/3 General Data 2/6 Technical Data 2/7 Declaration of conformity Siemens LV 56 · 2008 SIVACON S4 Power Distribution Boards Introduction ■ Front view 2 SIVACON S4 is an AS (TTA-TSK) switchgear and controlgear system, type tested according to IEC 60439-1, CEI EN 60439-1, for installation as primary or secondary boards in industrial and service sector facilities, including hospitals, shopping centres, banks, schools. etc. The SIVACON S4 energy distribution concept consists of a full line-up of boards in galvanised 2/2 Siemens LV 56 · 2008 chromed sheet steel, of sturdy design, suitable for any installation modality: self-standing, flush or wall-mounted. SIVACON S4 low-voltage power distribution boards are constructed according to a modular design system and, by means of ad hoc assembly kits, can be combined to meet all power distribution needs. SIVACON S4 Power Distribution Boards General data ■ Description System SIVACON S4 is a system of low-voltage power distribution boards, for indoor use, panelled on four sides, suitable for selfstanding or wall-mounted installation. 2 The cubicle The constituent elements of the cubicle framework, having a 2.5mm thick profile, are inserted into one another to form a parallelepiped shaped column. This provides the bearing structure supporting all add-on interior switchgear components, i.e., assembly kits, busbar systems, mounting plates, etc. Stable and rugged construction is ensured through the use of Torx selftapping screws. Equipotential and safe grounding of all parts are also achieved. The enclosure Enclosure parts made of galvanised sheet steel are dimensioned as a function of the cubicle they are fitted to. Different versions make it possible to achieve various degrees of protection: IP 30/31, IP 40/41 or IP 55. Walls and doors are coated with slightly embossed RAL 7035 powder-paint. In addition to the standard two-way interlocking system, the doors can be equipped with numerous types of operating mechanism including rotary handles, with or without locks, to meet any need. Assembly kit covers are secure by means of captive quickrelease screws. Opening and closing is by rotating the handle by 1/4 turn. Using the hinge option, the covers may open to the right or to the left. Busbar system The main busbar system of SIVACON S4 offers an appropriate scaling of rated currents, matched to a rated current of up to 4000 A and short-circuit currents of standard transformers. It is possible to set up systems with network configurations such as TN-C, TN-S, IT and TT. Vertical distribution busbar systems are available as cascaded versions up to 1600 A or noncascaded versions up to 2700 A. Internal separation Assemly kits For open and enclosed automatic breakers, disconnectors, SENTRON circuit breakers, modular units as well as contactors, a wide range of dedicated kits are available. Modular adjustable mounting plates or plates for electrotechnical use, as well as dedicated ventilation and air-conditioning components complete the line-up of parts for the construction of boards as typically used at industrial facilities or for automation purposes. The items available include a range of assembly kits for Siemens Sentron WL and VL circuit breakers, in fixed, plug-in and drawout versions, as well as kits with DIN rails, according to DIN 43656, for the wide range of the Beta Series modular devices. • The components of the cubicle and the assembly kits are made of galvanised chromed sheet. • The components of the enclosure, such as panels and doors are coated with slightly embossed RAL 7035 powder-paint. • Air-conditioning components complete the line-up of SIVACON S4 system components. Depending on individual requirements, internal partitions are available from form 1 to form 4. Siemens LV 56 · 2008 2/3 SIVACON S4 Power Distribution Boards General Data ■ Applications Main features 2 • Type AS (TTA-TSK) power distribution boards according to CEI EN 60439-1. • Modular systems supplied loose (supplied as assembly kits with individually packaged components, including fasteners; assembly instructions for do-it-yourself installation). • New design, ventilation and closing system. • Slightly embossed RAL 7035 powder coating. • Doors with universal stop. • Degree of protection IP30, IP31, IP40, IP41, IP55 • Busbar system rated current up to 4000 A • Busbar system short-circuit current Icw up to 100 kA (1s). • Busbar system peak current Ipk up to 220 kA. • Height 2000 mm • Width 400, 600, 800, 1000, 1200 mm. • Depth 400, 600, 800 mm. • Kits for Sentron 3WL, 3VL, 3KA, 3KL circuit breakers, Beta modular devices on DIN rails. • Kits of prefabricated bars for Sentron 3WL, 3VL circuit breakers. • Internal separation form 1, 2, 3, 4. • Easy design and configuration with the SCFB software tool. Construction and testing modalities All installation and wiring operations must be performed in keeping with the information and data given in the catalogues and the assembly manuals. The installation and individual testing of the low-voltage boards must be performed according to standards IEC 60439-1 and CEI EN 60439-1. Protection of the environment To the best of our knowledge, our materials do not contain materials in concentrations or applications prohibited by directive 2002/95/EC (RoHs). All the materials used are recyclable. 2/4 Siemens LV 56 · 2008 SIVACON S4 Power Distribution Boards Quick and easy assembly ■ Exploded view 5 2 6 15 13 11 8 4 9 1 16 12 14 7 6 10 16 17 01724 18 2 3 1 Cubicle 7 Giugiaro Design glazed wall 2 Base with front covers 8 Front frame 13 Horizontal busbars Vertical distribution busbars, 14 non-cascaded 3 Base side covers 9 Cable compartment cover 15 Real panel 4 Supporting Structure 10 Covers for equipment kits Mounting plate for 16 Sentron VL circuit breaker 5 Blind top plate 11 Segregation for horizontal busbars 17 Blind bottom plate 6 Side panel with design 12 Segregation for vertical distribution busbars 18 Main grounding bar PE Siemens LV 56 · 2008 2/5 SIVACON S4 Power Distribution Boards Technical Data ■ Overview 2 Standards and regulations Type AS (TTA-TSK) assembled protection and circuit breakers for low-voltage (L.V. boards) Air clearances and creepage distances Rated impulse withstand voltage (Uimp) Overvoltage category Pollution degree IEC 60439-1, EN 60439-1 12 kV IV 3 1, 2b, 3b, 4a, 4b Internal separation forms 1000 V Rated insulation voltage (Ui) Up to Rated operational voltage (Ue) 50/60 Hz Rated frequency Rated current (In) of (3-pole and 4-pole) busbar system Main horizontal bars Protection of people in the event of internal arcs Type tested according to IEC 61641 Degree of protection ≤ IP40, without glazed door Rated current Rated peak current of busbar system (Ipk) Rated short-time current of busbar system (Icw) Up to Up to Rated utilisation voltage Rated short-time current without extra kit Length of internal arc without extra kit Length of internal arc with extra kit Galvanised Epoxy resin Cold phosphatised Thickness of coating 20 µm RAL 7035 min. 70 µm Insulation class According to IEC 61140, EN 61140 Degree of protection According to IEC 60529, EN 60529 IP 30, IP 31, IP 40, IP 41, IP 55 Resistance to mechanical impacts According to IEC 62262, paragraph 9.6 IP 3X ≥ IP 4X Additional static loads on frame components Front frame revolving fixed with quick closing screws, H 50-300mm with quick closing screws, H 350-550mm with quick closing screws, H 600-800mm with hinges Internal inner door Internal door / double door Door module 400 V 50 kA 100 ms 300 ms min. Cubicle, interior components, enclosure Coated with RAL 7035 powder Covers 4000 A 220 kA Up to 100 kA, 1s Surface treatment SK1 IK08 IK10 W 400, 600mm W 800mm W 1000, 1200mm H 150-200mm H 250-350mm H 400-800mm Exterior covers Max construction weight 690 V According to IEC 62208, paragraph 9.3, 9.4, Type tested with static load by lifting a cubicle 1,0 kg 5,0 kg 0,5 kg 1,0 kg 2,0 kg 0,0 kg 2,5 kg 10,0 kg 5,0 kg 2,5 kg 0,5 kg 1,5 kg 3,0 kg 10,0 kg 1200 kg Operating conditions Ambient temperature1) Installation altitude 35 °C 2000 m Frame parts: 2.5 mm – Galvanised chromed sheet steel, with 25mm hole pattern according to DIN 43 660 Dimensions Exterior dimensions Height: Width: Depth: 2000 mm 400, 600, 800, 1000, 1200 mm 400, 600, 800 mm Base Height: 100, 200 mm 1) For different ambient temperatures and installation altitudes, take into account the appropriate correction factors (see chapter on Planning and Configuration) 2/6 Siemens LV 56 · 2008 SIVACON S4 Power Distribution Boards Declaration of conformity ■ Overview 2 Siemens LV 56 · 2008 2/7 SIVACON S4 Power Distribution Boards Declaration of conformity ■ Overview 2 2/8 Siemens LV 56 · 2008 3 Standard Configurations 3/2 SIVACON S4 with Sentron 3VL circuit breakers and modular devices 3/3 SIVACON S4 with Sentron 3WL circuit breakers 3/4 SIVACON S4 with Sentron 3VL circuit breakers 3/5 SIVACON S4 with Sentron 3WL, 3VL circuit breakers and modular devices Siemens LV 56 · 2008 Standard Configurations SIVACON S4 with Sentron 3VL circuit breakers and modular devices ■ Power distribution board data Height x Width x Depth Height of base, Degree of protection Main busbar system Vertical busbar system Front Internal separation ■ Assembly kit 2000mm x 1200mm x 400mm 100mm IP55 without cascaded 1250 A, 50kA covers, full height door 2b Infeed Sentron 3VL1250, cable entry from top, terminals for cables, extended terminal covers Sentron 3VL, extended terminal covers, modular devices Starters Cubicle, base, Supporting Structure, enclosures 8PQ1202-4BA02 8PQ3000-1BA38 8PQ3000-1BA43 8PQ1012-0BA01 8PQ1010-4BA01 8PQ2000-6BA04 8PQ2197-2BA14 8PQ2197-6BA14 8PQ2197-4BA05 8PQ2302-4BA04 8PQ2306-4BA05 8PQ2304-4BA05 8PQ2302-4BA01 8PQ2420-2BA01 8PQ2520-4BA01 3 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 Cubicle H2000/B1200/T400 Bottom plate partition crossbar Exterior intermediate supporting structure Base H100/B1200 Base side covers H100/P400 Fixed front frame H1800/B600 Cable compartment cover B200 IP55 glazed door, right/2-way interlock./H1975/B600 IP55 door, left/2-way interlock./H1975/B400 Bottom plate IP55/B200/P400 Bottom plate IP55/B600/P400 Bottom plate IP55/B400/P400 Top plate IP55/B1200/P400 Rear panel IP55/H2000/B1200 Side panel with design/H2000/P400 1 8 1 Support for vertical busbars, cascaded, 30x30 Copper busbar 30x10/L2000 Copper busbar 30x5 /L2000 Busbar system 02001 8PQ4000-0BA32 8PQ4000-0BA86 8PQ4000-0BA85 Kits for switchgear, covers, mounting plates 8PQ2020-6BA02 8PQ6000-3BA11 8PQ2060-6BA03 8PQ2020-6BA01 8PQ6000-3BA36 8PQ2015-6BA07 8PQ6000-3BA18 8PQ2020-6BA04 8PQ6000-2BA87 8PQ2025-6BA02 1 1 1 1 1 1 2 2 1 1 Instrum. cover 4X72x72 + 1 sw./H200/B600 Kit for 3VL 7, 3/4 poles, vertical/H600/P600 Cover 3VL 7 3/4 poles, vertical/H600 B600 Cover H200/B600 DIN 24UM/B600 rail assembly kit Cover for modular elements 24UM/H150/B600 Assembly kit for 3VL 2, 3, 4 poles, horiz./H200/B600 Cover for 3VL 1 3,3, 4 poles, horiz./H200/B600 Assembly kit 3VL 4, 4 poles, horiz./H250/B600 Cover for 3VL4, horiz. fixed, remov./H250/B600 Kits for switchgear, busbar connection 8PQ6000-1BA64 8PQ6000-1BA66 2 1 Vertical busbar connection kit for 3VL 3./4p/horiz./fixed Vertical busbar connection kit for 3VL 4 /4p/horiz./fixed 1 Vertical partition for distribution busbars, form 2b H1900/P400 1 1 1 1 1 1 SIVACON – SIEMENS cubicle ID plate Cable anchoring brackets C30/P400 (600, 800) Flat head square screws DIN 603 M10X55 Nuts M10 ISO 4032/M10 Clamping washer DIN 6796/10 Busbar connect. kit cable, conductors, small parts, screws, nuts, washers with locking edges for cable connection Internal separation 8PQ4000-0BA06 Accessories 02003 02002 8PQ9400-0BA06 8PQ3000-0BA38 8PQ9500-1BA36 8PQ9500-0BA05 8PQ9500-0BA60 8PQ9400-0BA02 3/2 Siemens LV 56 · 2006 Standard Configurations SIVACON S4 with Sentron 3WL circuit breakers ■ Power distribution board data Height x Width x Depth Height of base Degree of protection Main busbar system Distribution busbar system, vertical Front Internal segregation ■ Assembly kit 2000mm x 2000mm x 600mm 100mm IP30 Standard at top, 3200A, 65kA cascaded, 2 x 1600A panels, cover 4b Infeed / starters Sentron 3WL Gr. II, fixed, connection to distribution busbars. Cables from top/bottom Max 12 cables per phase per M12 cable terminal 02004 Cubicle, base, Supporting structure, enclosure 8PQ1208-6BA01 8PQ1204-6BA01 8PQ3000-0BA01 8PQ3000-0BA03 8PQ1204-4BA05 8PQ1018-0BA01 8PQ1014-0BA01 8PQ1010-6BA01 8PQ2000-8BA03 8PQ2000-8BA03 8PQ2197-8BA11 8PQ2197-8BA11 8PQ2308-6BA06 8PQ2304-6BA05 8PQ2308-6BA03 8PQ2308-6BA02 8PQ2304-6BA02 8PQ2420-8BA02 8PQ2420-4BA02 8PQ2520-6BA01 2 1 2 1 2 2 1 1 2 1 2 1 1 1 1 1 1 2 1 1 Cubicle H2000/ B800/P600 Cubicle H2000/B400/P600 Interior side upright H1600/P600 Interior side upright H1800/P600, 800 Board coupling kit Base with front covers H100/B800 Base with front covers H100/B400 Base side covers H100/P600 Fixed front frame H1600/B800 Exterior cover IP4X/H1975/B400 Finishing frame IP3X/H1975/B800 Bottom plate IP55/B800/P600 Bottom plate IP4X/cables/B800/P600 Bottom plate IP55/B400/P600 Top plate IP4X/cables/B800/P600 Top plate IP4X//B800/P600 Top plate IP4X/B400/P600 Rear panel IP4X/H2000/B800 Rear panel IP4X/H2000/B400 Side panel with design H2000/P600 2 1 1 2 2 16 16 2 Main busbars holder 3200 A Flying support (reinforcement) Support for grounding bar PE Support for vertical cascaded busbar /30x40 Kit for vertic./horiz. busbars 30x40/P600, 800 Copper busbar 50x10/L2000 Copper busbar 40x10/L2000 Copper busbar 40x5 / L2000 3 Busbar system 8PQ4000-0BA04 8PQ4000-0BA37 8PQ4000-0BA82 8PQ4000-0BA63 8PQ4000-0BA74 8PQ4000-0BA18 8PQ4000-0BA17 8PQ4000-0BA80 Kits for switchgear, covers, mounting plates 8PQ6000-3BA32 8PQ2055-8BA05 8PQ2055-8BA01 8PQ2050-8BA01 2 2 2 2 Kit for 3WL11 12,3/4 poles/fixed H550/B800 Cover for 3WL12/4P/H550/B800 Cover H550/B800 Cover H500/B800 Kits for switchgear, busbar connection 8PQ6000-0BA47 8PQ6000-0BA65 2 2 prefabricated distribution bars for 3WL1232/fixed/B800 prefabricated bars to cables for 3WL 1232/fixed/B800 1 1 1 2 2 2 2 Separation form 2b, main busbars B800/P600 Separation form 2b, distribution bars H1900/P600 Separation form 2b, distribution bars H1600/P600 Partition supporting rail H1600 Separation form 3 3WL12/3-4 poles/pull-out/H550/B800 Separation form 4 3WL12/3-4 poles/vert. bars/B800 Separation form 4 3WL12/3-4 poles/cables/B800 1 3 1 2 3 3 2 2 SIEMENS SIVACON column ID plate Busbar connection kit Flat head screw DIN 603/M10x45 Flat head screw DIN 603/M10x65 Clamping washer DIN 6796/10 Hexagonal nut ISO4032/M10 Cable anchoring bracket Cable anchoring bracket C30/B800 cable, conductors, small parts, screws, nuts, washers with locking edges for cable connection 02005 Internal separation 8PQ3000-0BA54 8PQ4000-0BA03 8PQ4000-0BA07 8PQ3000-0BA82 8PQ5000-0BA10 8PQ5000-0BA21 8PQ5000-0BA38 Accessories 02006 8PQ9400-0BA06 8PQ9400-0BA02 8PQ9500-0BA16 8PQ9500-1BA25 8PQ9500-0BA60 8PQ9500-0BA05 8PQ3000-0BA73 8PQ3000-0BA43 Siemens LV 56 · 2008 3/3 Standard Configurations SIVACON S4 with Sentron 3VL and modular devices ■ Power distribution board data Height x Width x Depth Height of base Degree of protection Main busbar system Distribution busbar system, vertical Front Internal separation ■ Assembly kit 2000mm x 1400mm x 400mm 100mm IP55 without non-cascaded 630 A, 15kA covers, full height door 1 Infeed Sentron 3VL 630, cable entry from top, terminals for several wires, extended terminal covers Sentron 3VL extended terminal covers, modular devices Starters Cubicle, base, Supporting structure, enclosure 8PQ1206-4BA01 8PQ1208-4BA01 8PQ3000-1BA38 8PQ3000-1BA42 8PQ1204-4BA05 8PQ1204-4BA04 8PQ1016-0BA01 8PQ1018-0BA01 8PQ1010-4BA01 8PQ2000-6BA04 8PQ2000-2BA01 8PQ2197-8BA14 8PQ2197-6BA10 8PQ2302-4BA04 8PQ2306-4BA05 8PQ2308-4BA01 8PQ2306-4BA01 8PQ2420-8BA01 8PQ2420-6BA01 8PQ2520-4BA01 02007 3 1 1 1 1 1 1 1 1 1 2 1 1 1 1 2 1 1 1 1 1 Cubicle H2000/ B600/P400 Cubicle H2000/B800/P400 Bottom plate partition crossbar P400 Exterior intermediate upright for covers Board coupling kit Switchboard coupling gasket IP55 Base with front covers H100/B600 Base with front covers H100/B800 Base side covers H100/P400 Fixed front frame H1800/B600 Covers for cable compartment IP3X/H2000/B200 IP55 glazed door/right/2-way interlock./H1975/B800 IP55 glazed door/left/2-way interlock./H1975/B600 Bottom plate IP55/B200/P400 Bottom plate IP55/B600/P400 Top plate IP55/B800/P400 Top plate IP4X/B600/P400 Rear panel IP55/H2000/B800 Rear panel IP55/H2000/B600 Side panel with design H2000/P400 10 2 8 1 Main busbar holder 30x10.50mm Exterior intermediate upright for covers Copper busbars 30x10/L2000 Copper busbars 20x5 / L2000 Busbar system 8GF5763 8PQ3000-1BA42 8PQ4000-0BA86 8PQ4000-0BA83 Kits for switchgear, covers, mounting plates 8PQ2020-6BA02 8PQ3000-1BA56 8PQ6000-3BA05 8PQ2040-6BA08 8PQ6000-3BA18 8PQ2020-6BA04 8PQ2020-6BA12 8PQ6000-3BA36 8PQ3000-1BA61 8PQ2040-6BA01 8PQ6000-3BA22 8PQ2035-6BA03 8PQ2005-6BA01 1 1 1 1 1 1 8 8 1 1 2 2 2 Cover for 4 instruments 1 sw. 72x72 H200/B600 Blind mounting plate kit H200/B600 Assembly kit for 3VL5 3, 4 poles/vertic. H400/B600 Cover for 3VL5 3, 4 poles/vertic./fixed, rim H400/B600 Assembly kit for 3VL2 3, 4 poles/horiz./fixed/H200/B600 Cover for 3VL1 3, 4 poles/horiz./fixed H200 B600 Cover for modular devices, 1 row, 24 UM/H200/B600 Modular DIN rails kit. 1 row, 24 UM/B600 Modular mounting plate H400/B600 Cover H400/B600 Assembly kit for 3VL2 3, 4 poles/vertic./fixed/H350/B600 Cover for 3VL1 3,4 poles/vertic./fixed, remov. H350/B600 Cover H50/B600 1 1 1 1 1 SIEMENS SIVACON column ID plate Cable anchoring brackets Cable anchoring brackets C30/B600 Horizontal raceway fastening bracket 35mm DIN rail for terminal board L1600 cable, conductors, small parts, screws, nuts, washers with locking edges for cable connection Accessories 02009 02008 8PQ9400-0BA06 8PQ3000-0BA73 8PQ3000-0BA42 8PQ6000-0BA16 8PQ9600-0BA01 3/4 Siemens LV 56 · 2006 Standard Configurations SIVACON S4 with Sentron 3WL, Sentron 3VL and modular devices ■ Power distribution board data Height x Width x Depth Height of base Degree of protection Main busbar system Distribution busbar system, vertical Front Internal separation ■ Assembly kit 2000mm x 2200mm x 600mm 100mm IP30 without cascaded, 1600A, 50 kA 50mm System covers, glazed door 4b Infeed Connector Starters Sentron 3WL Gr. I, fixed, central connection to main busbars, cable entry from top/bottom Sentron 3WL, Gr. I, fixed Sentron 3VL with rear attachments for cable connection at rear Modular devices 02019 Cubicle, base, Supporting structure, enclosure 8PQ1206-6BA01 8PQ1208-6BA01 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-1BA36 8PQ3000-1BA42 8PQ1204-4BA05 8PQ1016-0BA01 8PQ1018-0BA01 8PQ1010-6BA01 8PQ2000-6BA04 8PQ2000-2BA01 8PQ2197-6BA10 8PQ2197-8BA10 8PQ2302-6BA04 8PQ2306-6BA05 8PQ2306-6BA02 8PQ2308-6BA02 8PQ2420-6BA02 8PQ2420-8BA02 8PQ2520-6BA01 1 2 2 3 2 2 2 1 2 1 3 2 1 2 2 3 1 2 1 2 1 Cubicle H2000/ B600/P600 Cubicle H2000/B800/P600 Bottom plate partition crossbar P600 Interior side upright H1800/P600, 800 Interior side upright H1800/P600 Exterior intermediate upright Board coupling kit Base with front covers H100/B600 Base with front covers H100/B800 Base side covers H100/P600 Fixed front frame H1800/B600 Covers for cable compartment IP3X/H2000/B200 IP55 glazed door/left/2-way interlock./H1975/B600 IP55 glazed door/left/2-way interlock./H1975/B800 Bottom plate IP55/B200/P600 Bottom plate IP55/B600/P600 Top plate IP4X/B600/P600 Top plate IP4X/B800/P600 Rear panel IP4X/H2000/B600 Rear panel IP4X/H2000/B800 Side panel with design H2000/P600 2 1 4 16 9 Support for distribution busbars, cascaded 30x40 Support for busbar PE Support for busbars 20x5.50mm Copper busbars 40x10/L2000 Copper busbars 20x5/L2000 3 Busbar system 8PQ4000-0BA63 8PQ4000-0BA82 8GF5762 8PQ4000-0BA17 8PQ4000-0BA83 02020 Kits for switchgear, covers, mounting plates 8PQ6000-3BA31 8PQ2055-6BA07 8PQ6000-2BA87 8PQ2025-6BA02 8PQ6000-3BA18 8PQ2020-6BA04 8PQ6000-3BA10 8PQ2035-6BA04 8PQ6000-3BA36 8PQ2020-6BA12 8PQ3000-1BA65 8PQ2040-6BA01 8PQ2060-6BA01 8PQ2030-6BA01 8PQ2025-6BA01 2 2 2 2 2 2 1 1 6 6 1 1 1 2 1 Kit for 3WL11 3, 4 poles/3WL12/3p/H550/B600 Cover for 3WL11/4p/H550/B600 Kit for 3VL4/4p/horiz./H250/B600 Cover for 3VL4/4p/horiz./fixed, remov./H250/B600 Kit for 3VL2-3, 4 poles/horiz./fixed/H200/B600 Cover for 3VL1 3, 4 poles/horiz./fixed, remov./H200/B600 Kit for 3VL5 4 poles/horiz./H350/B600 Cover for 3VL 5/4poles/horiz./fixed, remov./H350/B600 Modular DIN rails kit, 1 row, 24 UM/B600 Modular cover, 1 row, 24 UM/B600 Modular mounting plate H600/B600 Cover H400/B600 Cover H600/B600 Cover H300/B600 Cover H250/B600 Siemens LV 56 · 2008 3/5 Standard Configurations SIVACON S4 with Sentron 3WL, Sentron 3VL circuit breakers and modular device Kits for switchgear, busbar connection 8PQ6000-0BA34 8PQ6000-0BA52 8PQ6000-1BA64 8PQ6000-1BA66 8PQ6000-1BA68 3 1 2 2 1 Distribution busbar connection kit for 3WL11 16/fixed/B600 Cable connection kit for 3WL11 16/fixed/B600 Distribution busbar connection kit for 3VL3/4p/horiz./fixed Distribution busbar connection kit for 3VL4/4p/horiz./fixed Distribution busbar connection kit for 3VL5/horiz./fixed 2 3 7 1 1 2 2 2 3 1 2 2 5 Separ. form 2b for vertical bars H1900/P600 Supporting rail for crossbars and partitions H1800 Separ. form 3, horizontal/B600 Separ. form 3, vertic./rear/H350/B600 Separ. form 3, vertic./later./H350 Separ. form 3, vertic./rear/H200/B600 Separ. form 3, vertic./later./..250A/H200 Separ. form 3, 3WL11/3, 4 poles/estraib./H550/B600 Separ. form 4, 3WL11/3, 4 poles/cables/B600 Separ. form 4, 3WL11/3, 4 poles/distribuz./B600 Separ. form 3, vertic./rear/H250/B600 Separ. form 3, vertic./later./..400..630A/H250 Protective bellows 2 2 2 2 2 1 1 SIEMENS SIVACON column ID plate Busbar connection kit Flat head screw DIN 603/M10x65 Clamping washer DIN 6796/10 Hexagonal nut ISO4032/M10 Cable anchoring bracket Cable anchoring bracket C30/B800 without screws, nuts and washers with locking edges for cable connection Internal separation 8PQ4000-0BA03 8PQ3000-0BA83 8PQ5000-2BA61 8PQ5000-2BA57 8PQ5000-2BA36 8PQ5000-2BA54 8PQ5000-2BA30 8PQ5000-0BA07 8PQ5000-0BA30 8PQ5000-0BA14 8PQ5000-2BA55 8PQ5000-2BA33 8PQ9400-0BA03 02021 3 Accessories 8PQ9400-0BA06 8PQ9400-0BA02 8PQ9500-1BA25 8PQ9500-0BA60 8PQ9500-0BA05 8PQ3000-0BA73 8PQ3000-0BA42 3/6 Siemens LV 56 · 2006 Cubicle, Supporting Structure and Enclosure 4 4/2 General Data 4/4 Cubicles and Supporting Structure 4/8 Base 4/9 Enclosure Siemens LV Siemens LV56 56· ·2008 2008 Cubicle, Supporting Structure and Enclosure General Data ■ Overview 8 5 4 1 3 4 9 9 10 10 5 NSE0_01670 7 2 6 1 Cubicle 6 Base besides covers 2 Base with front covers 7 Bottom plate 3 Glazed door Giugiaro Design 8 Top plate 4 Rear wall 9 Supporting structure for main busbars in standard position 10 Supporting structure for main busbars in standard position and riser compartment 600mm + 200mm 5 Side panel with design bar 4/2 Siemens LV 56 · 2008 Cubicle, Supporting Structure and Enclosure General Data ■ Overview Cross section of possible combinations of cubicles, Supporting structureand enclosures seen from above. 6 1 2 Internal cover B200 3 2 1 Supporting structure external for cover 3 Cover frame 02022 4 4 Cubicle panelling IP3X or 5 5 Door IP4X, IP55 4 6 Cubicle 6 1 2 Outer plate B200, 400 or door B400, 600 3 2 3 Cover frame 02023 4 2 1 Supporting structure external for door 4 Cubicle panelling IP3X or 5 5 Door IP4X, IP55 6 Cubicle 4 1 02024 2 2 1 Supporting structure external for door 2 Outer plate B200, 400 or door B400, 600 3 3 Modular door 4 Cubicle Siemens LV 56 · 2008 4/3 Cubicle, Supporting Structure and Enclosure Cubicle and supporting structure ■ Description ■ Configuration The cubicle is a framework consisting of vertical and horizontal sections plus the fasteners necessary to assemble them. This provides the bearing structure support to all add-on interior switchgear components. Stable and rugged construction is achieved through the use of galvanised sections and self-tapping screws. Equipotential and safe grounding of all constituent parts are also achieved. The values quoted below are the external dimensions. A complete configuration is made of the following elements: cubicle, bottom plate partition crossbar and supporting structure for equipment heights of 1600mm or 1800mm. To assemble two or more cubicles by width or depth, request the board coupling kit for each coupling point. The cubicle uprighte have holes spaced 25 mm apart for anchoring to the base or the floor. In the upper part these holes make it possible to fit crossbars, or eyebolts for board handling purposes. The installation of interior components, kits, crossbars, supporting parts, etc., is facilitated by the presence of height, width and depth locators. The supporting structure is made up of a vertical section, crossbars and fastening screws. In cubicles of various heights and width it ensures segregation between the equipment compartment and the busbar compartment, partitioning the cubicles into equipment compartments and main, or distribution, busbars compartments. – Bottom plate partition not required +++ Function performed by the cubicle ■ Selection and ordering data Height mm Width mm Dept mm Cubicle 02027 02026 02025 Supporting strucutre 01797 4 Bottom plate partition 1800 mm Equipment height 1600 mm Cubicle and supporting structure with one section 2000 400 400 8PQ1204-4BA01 – +++ 8PQ3000-0BA65 2000 600 400 8PQ1206-4BA01 – +++ 8PQ3000-0BA65 2000 800 400 8PQ1208-4BA01 – +++ 8PQ3000-0BA65 2000 1000 400 8PQ1201-4BA02 8PQ3000-1BA38 +++ 8PQ3000-0BA65 2000 1200 400 8PQ1202-4BA02 8PQ3000-1BA38 +++ 8PQ3000-0BA65 2000 400 600 8PQ1204-6BA01 – 8PQ3000-0BA03 8PQ3000-0BA01 2000 600 600 8PQ1206-6BA01 – 8PQ3000-0BA03 8PQ3000-0BA01 2000 800 600 8PQ1208-6BA01 – 8PQ3000-0BA03 8PQ3000-0BA01 2000 1000 600 8PQ1201-6BA02 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-0BA01 2000 1200 600 8PQ1202-6BA02 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-0BA01 2000 400 800 8PQ1204-8BA01 – 8PQ3000-0BA03 8PQ3000-0BA02 2000 600 800 8PQ1206-8BA01 – 8PQ3000-0BA03 8PQ3000-0BA02 2000 800 800 8PQ1208-8BA01 – 8PQ3000-0BA03 8PQ3000-0BA02 2000 1000 800 8PQ1201-8BA03 2x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-0BA02 2000 1200 800 8PQ1202-8BA02 2x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-0BA02 4/4 Siemens LV 56 · 2008 Cubicle, Supporting Structure and Enclosure Cubicle and Supporting structure ■ Description ■ Configuration The supporting structure external is made up of a vertical section and the relative fasteners. The values quoted below are the external dimensions. The Supporting structure for internal covers constitutes a cubicle upright that makes it possible to fit a front frame and an interior cover in front of a cubicle part 200mm in width. The Supporting strucutre for outer covers/door constitutes two cubicle uprights and makes it possible to fit modular doors/a front frame and a door/exterior cover. A complete configuration is made up of the following elements: cubicle, bottom plate partition crossbar, supporting structure, for an equipment height of 1800mm or 1600mm, and an supporting structure external for the installation of interior covers or an exterior cover/doors. For separation forms >1 when using 200mm, 400mm, 600mm cubicles, as cable compartment or equipment compartment request an additional supporting structure, see page 4/7. A combination of supporting structure external for internal covers and modular doors is not possible. To assemble two or more cubicles by width or depth, request the board coupling kit for each coupling point. – not possible +++ Function performed by the supporting structure external ■ Selection and ordering data Supporting structure external Height mm Width mm Depth mm Cubicle partition Cubicle Bottom plate crossbar 02030 02029 02028 02025 01797 Interior intermediate side upright Equipment height For upgrade 1800 mm 1600 mm Internal covers Door auter covers Cubicles and Supporting structure with division into two sections 2000 800 400 600+200 8PQ1208-4BA01 8PQ3000-1BA38 +++ 8PQ3000-0BA65 8PQ3000-1BA31 8PQ3000-1BA42 8PQ3000-1BA43 2000 1000 400 600+400 8PQ1201-4BA02 8PQ3000-1BA38 +++ 8PQ3000-0BA65 8PQ3000-1BA31 – 8PQ3000-1BA43 2000 1000 400 800+200 8PQ1201-4BA02 8PQ3000-1BA38 +++ 8PQ3000-0BA65 8PQ3000-1BA31 8PQ3000-1BA42 8PQ3000-1BA43 2000 1200 400 600+600 8PQ1202-4BA02 8PQ3000-1BA38 +++ 8PQ3000-0BA65 8PQ3000-1BA31 – 8PQ3000-1BA43 2000 800 600 600+200 8PQ1208-6BA01 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-1BA36 8PQ3000-0BA01 8PQ3000-1BA32 8PQ3000-1BA42 8PQ3000-1BA43 2000 1000 600 600+400 8PQ1201-6BA02 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-1BA36 8PQ3000-0BA01 8PQ3000-1BA32 – 8PQ3000-1BA43 2000 1000 600 800+200 8PQ1201-6BA02 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-1BA36 8PQ3000-0BA01 8PQ3000-1BA32 8PQ3000-1BA42 8PQ3000-1BA43 2000 1200 600 600+600 8PQ1202-6BA02 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-1BA36 8PQ3000-0BA01 8PQ3000-1BA32 – 8PQ3000-1BA43 2000 800 800 600+200 8PQ1208-8BA01 2x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-1BA37 8PQ3000-0BA02 8PQ3000-1BA34 8PQ3000-1BA42 8PQ3000-1BA43 2000 1000 800 600+400 8PQ1201-8BA03 2x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-1BA37 8PQ3000-0BA02 8PQ3000-1BA34 – 8PQ3000-1BA43 2000 1000 800 800+200 8PQ1201-8BA03 2x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-1BA37 8PQ3000-0BA02 8PQ3000-1BA34 8PQ3000-1BA42 8PQ3000-1BA43 2000 1200 800 600+600 8PQ1202-8BA02 2x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-1BA37 8PQ3000-0BA02 8PQ3000-1BA34 – 8PQ3000-1BA43 Siemens LV 56 · 2008 4/5 4 Cubicle, Supporting Structure and Enclosure Cubicle supporting structure ■ Description ■ Configuration The supporting structrure external is made up of a vertical section and the relative fasteners. The supporting structure external of internal covers constitutes a cubicle upright and makes it possible to fit a front frame and an interior cover in front of a cubicle part 200mm in width. The supporting structure external outer cover/doors constitutes two cubicle uprights and makes it possible to fit externally modular doors/a front frame and a door/ cover. The values quoted below are the external dimensions. A complete configuration is made up of the following elements: cubicle, bottom plate partition crossbar, side supporting structure for an equipment height of 1800mm or 1600mm and an intermediate upright. The exterior intermediate upright consists of the following combination of: 2 Supporting structure external for internal covers or 1 Supporting structure external for internal covers and 1 intermediate upright for exterior cover/door. or 2 Supporting structure external for outer cover/door A combination of exterior intermediate upright for interior covers and modular doors is not possible. 4 For separation forms >1 when using 200mm, 400mm, 600mm cubicles, as cable compartment or equipment compartment request an additional intermediate upright, see page 4/7. To assemble two or more cubicles by width or depth, request the board coupling kit. +++ Function performed by the exterior supporting structure ■ Selection and ordering data Width mm Depth Cubicle submm division into sections Cubicle Bottom plate partition crossbars 02033 02032 02031 01797 Height mm Equipment height 1800 mm 1600 mm 02034 Supporting structure external Supporting structure For upgrade Interior covers Modular doors/exterior covers Cubicle and supporting structure with subdivision into three sections 2000 1000 400 200+600+200 8PQ1201-4BA02 2x 8PQ3000-1BA38 +++ 8PQ3000-0BA65 8PQ3000-1BA42 2x 8PQ3000-1BA31 8PQ3000-1BA43 2000 1200 400 400+600+200 8PQ1202-4BA02 2x 8PQ3000-1BA38 +++ 8PQ3000-1BA42 8PQ3000-0BA65 2x 8PQ3000-1BA31 8PQ3000-1BA43 2000 1200 400 200+800+200 8PQ1202-4BA02 2x 8PQ3000-1BA38 +++ 8PQ3000-0BA65 8PQ3000-1BA42 2x 8PQ3000-1BA31 8PQ3000-1BA43 2000 1000 600 200+600+200 8PQ1201-6BA02 8PQ3000-1BA42 2x 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-0BA01 2x 8PQ3000-1BA36 2x 8PQ3000-1BA32 8PQ3000-1BA43 2000 1200 600 400+600+200 8PQ1202-6BA02 8PQ3000-1BA42 2x 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-0BA01 2x 8PQ3000-1BA36 2x 8PQ3000-1BA32 8PQ3000-1BA43 2000 1200 600 200+800+200 8PQ1202-6BA02 8PQ3000-1BA42 2x 8PQ3000-1BA40 8PQ3000-0BA03 8PQ3000-0BA01 2x 8PQ3000-1BA36 2x 8PQ3000-1BA32 8PQ3000-1BA43 2000 1000 800 200+600+200 8PQ1201-8BA03 8PQ3000-1BA42 4x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-0BA02 2x 8PQ3000-1BA37 2x 8PQ3000-1BA34 8PQ3000-1BA43 2000 1200 800 400+600+200 8PQ1202-8BA02 8PQ3000-1BA42 4x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-0BA02 2x 8PQ3000-1BA37 2x 8PQ3000-1BA34 8PQ3000-1BA43 2000 1200 800 200+800+200 8PQ1202-8BA02 4x 8PQ3000-1BA38 8PQ3000-0BA03 8PQ3000-0BA02 8PQ3000-1BA42 2x 8PQ3000-1BA37 2x 8PQ3000-1BA34 8PQ3000-1BA43 4/6 Siemens LV 56 · 2008 Cubicle, Supporting Structure and Enclosure Cubicle and Supporting structure ■ Description The supporting structure is made up of vertical and horizontal sections and the relative fasteners. In cubicles of different depths the supporting structure ensures the creation of equipment and cable compartments and divides the cubicle into equipment compartment, main or distribution busbars compartment as well as cable compartment. ■ Configuration For sepation forms 2, 3, 4 when using 200mm, 400mm or 600mm cubicles, in a cubicle partitioned on the left/right as cable compartment or equipment compartment, order an supporting structure kit as an additional component. 1 required only for supporting structure external for internal covers 02035 02036 Supporting structure Height mm Depth mm 4 Equipment height 1800 mm 1600 mm Supporting structure 2000 400 8PQ3000-1BA42 1 8PQ3000-1BA31 2000 600 8PQ3000-1BA36 8PQ3000-1BA32 2000 800 8PQ3000-1BA37 8PQ3000-1BA34 ■ Description The kit for coupling two or more boards by width or depth consists of fastening plates and screws. The board coupling gasket kit with degree of protection IP55 consists of a self-adhesive gasket roll. . ■ Configuration To assemble two or more cubicles by width or depth, request a board coupling kit for each coupling point. For a degree of protection IP55, order an IP55 board coupling gasket kit as an additional component. Ordering code UI Board coupling by width or depth kit 8PQ1204-4BA05 8PQ1204-4BA05 1 IP55 board coupling gasket 8PQ1204-4BA04 8PQ1204-4BA04 1 Board coupling kit Siemens LV 56 · 2008 4/7 Cubicle, Supporting Structure and Enclosure Base ■ Description ■ Configuration The base kit is made of the following elements: corner pieces, front covers and the relative fasteners. Ad hoc covers to be order separately are available for the side covers. The covers of the base are not suitable for board transport and handling. For each board, consisting of one or more cubicles, the “side covers” kit must be ordered once for the H 100 base and twice for the H 200 base. For special situations, such as rolling, moving the cubicles on roller an ad hoc reinforcement kit is available (that can be applied along the width or the depth of the cubicle as a function of the direction of movement). Base reinforcements are mounted internally, at the front, back or side. ■ Selection and ordering data Height mm Depth mm Ordering code UI 1 01798 01642 Base with front covers 100 400 – 8PQ1014-0BA01 100 600 – 8PQ1016-0BA01 1 100 800 – 8PQ1018-0BA01 1 100 1000 – 8PQ1011-0BA01 1 100 1200 – 8PQ1012-0BA01 1 200 400 – 8PQ1024-0BA01 1 200 600 – 8PQ1026-0BA01 1 200 800 – 8PQ1028-0BA01 1 200 1000 – 8PQ1021-0BA01 1 200 1200 – 8PQ1022-0BA01 1 2 01643 Base covers besides 100 – 400 8PQ1010-4BA01 100 – 600 8PQ1010-6BA01 2 100 – 800 8PQ1010-8BA01 2 2 Base reinforcement 100 – 400 8PQ1014-0BA02 100 – 600 8PQ1016-0BA02 2 100 – 800 8PQ1018-0BA02 2 100 400 – 8PQ1014-0BA02 2 100 600 – 8PQ1016-0BA02 2 100 800 – 8PQ1018-0BA02 2 100 1000 – 8PQ1011-1BA01 2 100 1200 – 8PQ1012-2BA01 2 01078 01079 01644 4 Width mm Transport with base and lift truck 4/8 Siemens LV 56 · 2008 Transport with reinforced base and rollers Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration The front or blind covers of the various assembly kits are anchored to a “cover frame” by means of quick locking screws (a hinge kit can be an option to obtain a rotary cover). A cover frame 1600 or 1800 mm high in fixed or swivel versions is available. In the frame there is room to house the front covers of the assembly kits. The rotary mechanism enables the frame to be rotated over a 180° angle. This gives full access to the interior components of the board. The cover frame are available for 600 mm and 800 mm wide cubicles. Frame types available: – H 1600 mm frame for assembly kits with built-in covers for busbar systems in the upper part and grounding bars in the lower part. – H 1800 mm frame for assembly kits. For a rear upper busbar system, the space available in the upper section is 150 mm high and only 300 mm deep. This module can be used only for covers and DIN rail kits for modular units. For an exact selection, see also the notes in chapter 5 “busbar systems”. ■ Selection and ordering data Height for equipment mm Width mm Ordering code 1600 600 8PQ2000-6BA03 1 1600 800 8PQ2000-8BA03 1 UI 01802 Fixed cover frame for front main busbars Fixed cover frame without or with rear main busbars 600 8PQ2000-6BA04 1 1800 800 8PQ2000-8BA04 1 01803 1800 Swivel cover frame for front main busbars 600 8PQ2000-6BA02 1 1600 800 8PQ2000-8BA02 1 01626 1600 Swivel cover frame without or with rear main busbars 600 8PQ2000-6BA01 1 800 8PQ2000-8BA01 1 01625 1800 1800 Siemens LV 56 · 2008 4/9 4 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration For 200mm wide cubicle sections, an internal cover that can be mounted behind the door is available. The kit is made up of a cover, an anchoring support and fasteners. This cover must be used in conjunction with a cover frame and can be placed behind the door. When a 200mm section is produced in a cubicle, this section can be placed indifferently on the left or the right side, and is closed with an interior cover. For use only in conjunction with an supporting structure externa for internal covers. ■ Selection and ordering data Height of cover Width mm Degree of protection Ordering code UI 200 IP30 8PQ2000-2BA01 1 Internal cover for 200mm section ■ Description ■ Configuration A outer cover can be instead a door of 200mm and 400mm wide compartments. The covers can be can be mounted as desired on the front or the back of the cubicle. The kit includes a painted cover, a green column identification strip, an anchoring support and the relative fasteners. This cover must be used in conjunction with the cover frame or as an alternative to the door. For use only in conjunction with the supporting structure external for outer covers/door. ■ Selection and ordering data Height cover Width mm Degree of protection Ordering code UI Cubicle height 200 IP40 8PQ2197-2BA15 1 Cubicle height 400 IP40 8PQ2197-4BA02 1 Cubicle height 200 IP55 8PQ2197-2BA14 1 Cubicle height 400 IP55 8PQ2197-4BA01 1 01663 Outer cover ■ Description ■ Configuration For 600mm and 800mm wide cubicles with front frame, cubicle panelling are available as an alternative to doors. For use only in conjunction with a front frame. Only for 600mm and 800mm wide cubicles. With its thickness, the finishing frame ensures the same height as an adjacent door, as well as the same height of the cover of the uprights of the galvanised chromed cubicle. Cubicle panelling, covers and finishing frame achieve a degree of protection of IP30/31. ■ Selection and ordering data Height Width mm Degree of protection Ordering code UI Cubicle height 600 IP30 8PQ2197-6BA11 1 Cubicle height 800 IP30 8PQ2197-8BA11 1 Cubicle panelling 01636 4 01799 Cubicle height 4/10 Siemens LV 56 · 2008 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration The SIVACON S4 door kit is made up of Giugiaro Design glazed doors or metal plate doors, a green column identification strip, hinges and preassembled bar lock closing system with two-way interlocking mechanism. Standard version doors use a 3mm two-way interlocking system. The two-way interlocking mechanism can be replaced with a rotary handle (standard doors are not suitable for semicylindrical profiles). In cubicles with degree of protection IP40 the top plate, the doors and the rear wall must have the same degree of protection. The doors can be mounted indifferently to the front or back of the cubicle. Thanks to the new hinge and locking system, the door hinges can be fitted either on the left or the right. The position of the hinges can be easily modified at a later stage. If it is deemed necessary to fit a closing system with rotary handle and semi-cylindrical profile with security key, on account of cylinder depth, a series of dedicated doors with right or left side hinges are available. ■ Selection and ordering data 4 Door type Door height Door width mm mm Degree of protection Hinge position Ordering code UI 1 01634 01633 01635 Cubicle door with two-way interlocking system Finned plate door 1975 400 IP40 left 8PQ2197-4BA08 Finned plate door 1975 600 IP40 left 8PQ2197-6BA06 1 Finned plate door 1975 800 IP40 left 8PQ2197-8BA06 1 Finned plate door 1975 1000 IP40 left 8PQ2197-1BA06 1 Finned plate door 1975 400 IP40 right 8PQ2197-4BA11 1 Finned plate door 1975 600 IP40 right 8PQ2197-6BA13 1 Finned plate door 1975 800 IP40 right 8PQ2197-8BA13 1 Finned plate door 1975 1000 IP40 right 8PQ2197-1BA18 1 Plate door 1975 400 IP55 left 8PQ2197-4BA05 1 Plate door 1975 600 IP55 left 8PQ2197-6BA03 1 Plate door 1975 800 IP55 left 8PQ2197-8BA03 1 Plate door 1975 1000 IP55 left 8PQ2197-1BA03 1 Plate door 1975 400 IP55 right 8PQ2197-4BA10 1 Plate door 1975 600 IP55 right 8PQ2197-6BA12 1 Plate door 1975 800 IP55 right 8PQ2197-8BA12 1 Plate door 1975 1000 IP55 right 8PQ2197-1BA17 1 Glazed door 1975 600 IP55 left 8PQ2197-6BA10 1 Glazed door 1975 800 IP55 left 8PQ2197-8BA10 1 Glazed door 1975 1000 IP55 left 8PQ2197-1BA10 1 Glazed door 1975 600 IP55 right 8PQ2197-6BA14 1 Glazed door 1975 800 IP55 right 8PQ2197-8BA14 1 Glazed door 1975 1000 IP55 right 8PQ2197-1BA20 1 Siemens LV 56 · 2008 4/11 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration The SIVACON S4 door kit is made up of Giugiaro Design glazed doors or metal doors, a green column identification strip, hinges and preassembled bar lock closing system with rotary handle mechanism for semi-cylindrical profile. Standard version doors use a two-way interlocking mechanism. Semi-cylindrical profile: see chapter s10 “Accessories”. The doors can be mounted indifferently to the front or back of the cubicle. The hinges for double doors are hooked onto the cubicle externally. The double doors of 1000mm wide cubicles are split into a 600mm left section and a 400mm right section. Opening sequence: right and then left. The double doors of 1200mm wide cubicles are split 50/50. Opening sequence: right and then left. ■ Selection and ordering data Door type Door height Door width mm mm Degree of protection Hinge position Ordering code UI 01806 01805 01804 Door with rotary handle for semi-cylindrical profile DIN 18252/18254, 8 x 45° Finned plate door 1975 400 IP40 left 8PQ2197-4BA06 1 Finned plate door 1975 600 IP40 left 8PQ2197-6BA04 1 Finned plate door 1975 800 IP40 left 8PQ2197-8BA04 1 Finned plate door 1975 1000 IP40 left 8PQ2197-1BA07 1 Finned plate door 1975 400 IP40 right 8PQ2197-4BA07 1 Finned plate door 1975 600 IP40 right 8PQ2197-6BA05 1 Finned plate door 1975 800 IP40 right 8PQ2197-8BA05 1 Finned plate door 1975 1000 IP40 right 8PQ2197-1BA08 1 Plate door 1975 400 IP55 left 8PQ2197-4BA03 1 Plate door 1975 600 IP55 left 8PQ2197-6BA01 1 Plate door 1975 800 IP55 left 8PQ2197-8BA01 1 Plate door 1975 1000 IP55 left 8PQ2197-1BA04 1 Plate door 1975 400 IP55 right 8PQ2197-4BA04 1 Plate door 1975 600 IP55 right 8PQ2197-6BA02 1 Plate door 1975 800 IP55 right 8PQ2197-8BA02 1 Plate door 1975 1000 IP55 right 8PQ2197-1BA05 1 Glazed door 1975 600 IP55 left 8PQ2197-6BA07 1 Glazed door 1975 800 IP55 left 8PQ2197-8BA07 1 Glazed door 1975 1000 IP55 left 8PQ2197-1BA11 1 Glazed door 1975 600 IP55 right 8PQ2197-6BA08 1 Glazed door 1975 800 IP55 right 8PQ2197-8BA08 1 Glazed door 1975 1000 IP55 right 8PQ2197-1BA12 1 Double door with two-way interlocking mechanism 1975 1000 IP40 – 8PQ2197-1BA14 1 Finned plate door 1975 1200 IP40 – 8PQ2197-2BA11 1 Plate door 1975 1000 IP55 – 8PQ2197-1BA13 1 Plate door 1975 1200 IP55 – 8PQ2197-2BA10 1 01696 Finned plate door Double door with rotary handle for semi-cylindrical profile Finned plate door 1975 1000 IP40 – 8PQ2197-1BA16 1 Finned plate door 1975 1200 IP40 – 8PQ2197-2BA13 1 Plate door 1975 1000 IP55 – 8PQ2197-1BA15 1 Plate door 1975 1200 IP55 – 8PQ2197-2BA12 1 01698 4 In cubicles with degree of protection IP40, the top plate, the doors and the rear wall must have the same degree of protection. 4/12 Siemens LV 56 · 2008 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration The inner door kit includes a door and hinges. The inner door is mounted behind the main cubicle door and in front of the largesized mounting plate for electrotechnical applications. The inner door requires a depth of 30 mm and cannot be used in conjunction with a cover frame. ■ Selection and ordering data Height Width mm Ordering code UI Inner door 600 8PQ2000-6BA05 1 Cubicle height 800 8PQ2000-8BA05 1 Cubicle height 1000 8PQ2000-1BA01 1 01699 Cubicle height 4 Siemens LV 56 · 2008 4/13 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration Bottom plates are available with degree of protection IP55 without cable entry opening and with degree of protection IP40 with variable cable entry opening. For 800mm wide cubicles, order two 400mm deep bottom plates. For 800mm, 1000mm, 1200mm wide cubicles, bottom plate selection depends on the combination of variants corresponding to cubicle subdivision. ■ Selection and ordering data Width mm Depth mm Degree of protection Ordering code UI 200 400 IP55 8PQ2302-4BA04 1 400 400 IP55 8PQ2304-4BA05 1 600 400 IP55 8PQ2306-4BA05 1 800 400 IP55 8PQ2308-4BA05 1 200 600 IP55 8PQ2302-6BA04 1 400 600 IP55 8PQ2304-6BA05 1 600 600 IP55 8PQ2306-6BA05 1 800 600 IP55 8PQ2308-6BA05 1 400 400 IP40 8PQ2304-4BA06 1 600 400 IP40 8PQ2306-4BA06 1 800 400 IP40 8PQ2308-4BA06 1 400 600 IP40 8PQ2304-6BA06 1 600 600 IP40 8PQ2306-6BA06 1 800 600 IP40 8PQ2308-6BA06 1 Bottom plate without cable entry 01631 4 Bottom plate with variable cable entry 01632 1) Lieferbar ab 02/2007. 4/14 Siemens LV 56 · 2008 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration Top plates are available with degree of protection IP55 and IP40 without cable entry opening. A version with degree of protection IP40 with variable cable entry opening is also available. The top plates with degree of protection IP55 are secured with screws on one side and snap into the board structure on the other. By means of a further upgrade, degree of protection IPX1 can be achieved. For cubicles with degree of protection IP 40, the top plates, the bottom plates, the doors and the panels must have the same degree of protection IP 40. With the IPX1 upgrade, cubicles with degree of protection IP30 and IP40 can achieve degree of protection IP31 and IP41 respectively. Column height is increased by 62 mm. ■ Selection and ordering data Width mm Depth mm Degree of protection Ordering code UI 400 400 400 600 600 600 800 800 800 1000 1000 1000 1200 1200 1200 400 400 400 600 600 600 800 800 800 1000 1000 1000 1200 1200 1200 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 8PQ2304-4BA02 8PQ2304-6BA02 8PQ2304-8BA02 8PQ2306-4BA02 8PQ2306-6BA02 8PQ2306-8BA02 8PQ2308-4BA02 8PQ2308-6BA02 8PQ2308-8BA02 8PQ2301-4BA02 8PQ2301-6BA02 8PQ2301-8BA02 8PQ2302-4BA02 8PQ2302-6BA02 8PQ2302-8BA02 8PQ2304-4BA01 8PQ2304-6BA01 8PQ2304-8BA01 8PQ2306-4BA01 8PQ2306-6BA01 8PQ2306-8BA01 8PQ2308-4BA01 8PQ2308-6BA01 8PQ2308-8BA01 8PQ2301-4BA01 8PQ2301-6BA01 8PQ2301-8BA01 8PQ2302-4BA01 8PQ2302-6BA01 8PQ2302-8BA01 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 400 400 400 600 600 600 800 800 800 400 600 800 400 600 800 400 600 800 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 8PQ2304-4BA03 8PQ2304-6BA03 8PQ2304-8BA03 8PQ2306-4BA03 8PQ2306-6BA03 8PQ2306-8BA03 8PQ2308-4BA03 8PQ2308-6BA03 8PQ2308-8BA03 1 1 1 1 1 1 1 1 1 400 400 400 600 600 600 800 800 800 1000 1000 1000 1200 1200 1200 400 600 800 400 600 800 400 600 800 400 600 800 400 600 800 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 IPX1 8PQ2304-4BA04 8PQ2304-6BA04 8PQ2304-8BA04 8PQ2306-4BA04 8PQ2306-6BA04 8PQ2306-8BA04 8PQ2308-4BA04 8PQ2308-6BA04 8PQ2308-8BA04 8PQ2301-4BA03 8PQ2301-6BA03 8PQ2301-8BA03 8PQ2302-4BA03 8PQ2302-6BA03 8PQ2302-8BA03 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Top plate without cable entry 01628 01627 Top plate with cable entry 01630 Top plate upgrade for IPX1 01629 Siemens LV 56 · 2008 4/15 4 Cubicle, Supporting Structure and Enclosure Enclosure ■ Description ■ Configuration Rear panels are available with degrees of protection IP40 and IP55. Rear panels with degree of protection IP40 are galvanised chromed, and those with degree of protection IP55 are slightly embossed, RAL 7035 powder-coated. For cubicles with degree of protection IP 40, the top plates, the bottom plates, the doors and the rear panels must have the same degree of protection IP 40. ■ Selection and ordering data Width mm Depth mm Degree of protection Ordering code UI 2000 2000 400 IP40 8PQ2420-4BA02 1 600 IP40 8PQ2420-6BA02 1 2000 800 IP40 8PQ2420-8BA02 1 2000 1000 IP40 8PQ2420-1BA02 1 2000 1200 IP40 8PQ2420-2BA02 1 2000 400 IP55 8PQ2420-4BA01 1 2000 600 IP55 8PQ2420-6BA01 1 2000 800 IP55 8PQ2420-8BA01 1 2000 1000 IP55 8PQ2420-1BA01 1 2000 1200 IP55 8PQ2420-2BA01 1 01637 ■ Description ■ Configuration The side panels are powder-coated and are available with degree of protection IP 55, with or without Design bar. For each board, order one kit of side panels. ■ Selection and ordering data Width mm Depth mm Degree of protection Ordering code UI 2000 400 IP55 8PQ2520-4BA01 2 2000 600 IP55 8PQ2520-6BA01 2 2000 800 IP55 8PQ2520-8BA01 2 2000 400 IP55 8PQ2520-4BA02 2 2000 600 IP55 8PQ2520-6BA02 2 2000 800 IP55 8PQ2520-8BA02 2 01640 Side panel with design Side panel without design 01639 4 01789 Rear panel 4/16 Siemens LV 56 · 2008 5 Busbar System 5/2 General Data 5/3 Main busbar system 5/7 Vertical distribution busbar system 5/11 Compact busbar systems 5/13 Copper bars 5/14 Busbar connection fasteners Siemens LV Siemens LV56 56· ·2008 2008 Busbar System General Data ■ Overview 4 1 5 2 4 5 1 System of main busbar with rectangular profile 2 Main busbar extension kit 01676 3 Grounding bar PE 3 4 Busbar holder 5 Reinforcement 5/2 Siemens LV 56 · 2008 Busbar System Main busbar system ■ Technical specifications Admissible rated current for main busbar systems No. of bars per phase Dimensions [mm] 20 × 10 30 × 10 20 × 10 30 × 10 40 × 10 50 × 10 20 × 10 30 × 10 2 2 4 4 4 4 2×4 2×4 Rated current at an ambient temperature of 35 °C Depth of cubicle 400mm IP ≤ IP41 1190 1630 1920 2460 2980 3220 IP 55 965 1310 1420 1790 2150 2330 Depth of cubicle 600mm IP ≤ IP41 1190 1630 1920 2490 3040 3320 IP 55 965 1310 1540 1950 2350 2570 Depth of cubicle 800mm IP ≤ IP41 1190 1630 1930 2510 3100 3410 3700 4660 IP 55 965 1310 1650 2110 2560 2820 3000 3680 These values refer to normal operating conditions and indoor installation in accordance with IEC 60439-1, in particular, at an ambient temperature of 35°C (24h average). In different operating conditions, the correction factors given in the “Planning and Configuration” chapter have to be taken into account. Cross-sections for PE conductor No. of bars Dimensions [mm] Icw 1s 2 20 × 5 2 30 × 5 85 kA 2 40 × 5 100 kA 2 30 × 10 100 kA 65 kA 5 The cross-sections specified for PE conductors were type tested according to IEC 60439-1. According to IEC 60439-1 a PE conductor cross-section corresponding to 25% the cross-section of main conductors is also admissible. Determination of the number of reinforcements as a function of short-circuit current and cubicle width Busbar cross-section No of bars 2 Dimensions [mm] 20 × 10 2 30 × 10 4 20 × 10 4 30 × 10 4 40 × 10 4 50 × 10 2×41 20 × 10 2×41 30 × 10 No. of reinforcements as a function of Ipk, Icw and cubicle width Width [mm] 400 600 800 1000 1200 400 600 800 1000 1200 400 600 800 1000 1200 400 600 800 1000 1200 400 600 800 1000 1200 400 600 800 1000 1200 400 600 800 1000 1200 400 600 800 1000 1200 Icw = 25 kA Ipk = 52,5 kA 0 0 1 1 2 Icw = 35 kA Ipk = 73,5 kA 0 0 1 1 2 0 0 1 1 2 0 0 1 2 2 0 0 1 2 2 Icw = 50 kA Ipk = 105 kA 0 1 1 2 2 0 0 1 2 2 0 0 1 2 2 0 0 1 1 2 0 0 1 1 2 Icw = 65 kA Ipk = 143 kA Icw = 85 kA Ipk = 187 kA Icw = 100 kA Ipk = 220 kA 0 1 2 3 3 0 1 2 3 3 0 0 1 1 2 0 0 1 1 2 0 1 2 3 4 0 1 2 3 4 0 1 2 3 3 0 1 2 3 3 0 1 2 3 3 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 1) The number of reinforcements applies to a main busbar system. Since the 3700 A and 4000 A main busbar system is made up of two systems mounted in parallel, the number of reinforcements to be ordered must be doubled. For the determination of the distances between busbar holders and reinforcements, refer to the SIVACON S4 Manual. Siemens LV 56 · 2008 5/3 Busbar System Main busbar system ■ Description The main busbar system of SIVACON S4 offers an appropriate scaling of rated currents, matched to the rated currents of standard version circuit breakers and transformers. The busbar holders have been designed for the use of rectangular copper profiles. By using 2, 4 or 8 sub-conductors per phase, it is possible to achieve high resistance to short-circuits and make the connections without having to drill holes. This arrangement also simplify handling of one or more cubicles. The main horizontal busbar system provides for a variety of network configurations such as TN-C, TN-S, IT and TT. The connection of the PE bar to the cubicle is type-tested (resistance to short-circuits) and ensures a safe transfer of fault currents to the cubicle. For TN-C network systems, a type-tested connection (PEN jumper) between the PEN bar and the cubicle is available. ■ Configuration 01702 SIVACON S4 main busbar system in standard position - Installation position: front top - Cubicle depth 600 mm - Rated current up to 3200 A - Side upright for 1600mm high modules - Front frame for 1600mm high modules 01703 01704 SIVACON S4 main busbar system in standard position - Installation position: front rear - Cubicle depth 800 mm - Rated current up to 3200 A - Side upright for 1600mm high modules - Front frame for 1600mm high modules or - Front frame for 1800mm high modules mm; the 150mm high upper module must be used only to fit the front cover 01705 SIVACON S4 main busbar system in standard position - Installation position: front top and rear (double upper system) - Cubicle depth 800 mm - Rated current up to 4000 A - Side upright for 1600mm high modules - Front frame for 1600mm high modules 01701 SIVACON S4 main busbar system in standard position - Installation position: front top - Cubicle depth 400 mm - Rated current up to 3200 A - Side upright for 1600mm high modules - Front frame for 1600mm high modules 01692 SIVACON S4 main busbar system in optional position - Installation position: at different heights at rear - Cubicle depth 800 mm - Rated current up to 3200 A - Side upright for 1800 mm high modules - Front frame for 1800 mm high modules - To position the busbars at an optional height other than in the upper part of the cubicle, order two 350mm long crossbars per cubicle 01706 Main busbar system with PEN jumper - The PEN jumper establishes the connection between the PEN bar and the cubicle. 1 PEN jumper per cubicle is required PE bar connection - The connection of the PE bar to the cubicle is included in the main busbar kit 01710 5 SIVACON S4 main busbar system in standard position - Installation position: front top - Cubicle depth 800 mm - Rated current up to 3200 A - Side upright for 1600mm high modules - Front frame for 1600mm high modules 5/4 Siemens LV 56 · 2008 Busbar System Main busbar systems ■ Selection and ordering data 1 1 1 1 1 2 1 1 2 1 2 1 2 1 2 02038 02037 2 Single-cubicle transport unit 1 Main busbar holder 2 Reinforcement Multi-cubicle transport unit The number of reinforcements to be used depends on the value of the short-circuit current and cubicle width. The additional internal arc protection kit is required for arcing times of between 100 ms and 300 ms. Order one kit per side panel. ■ Selection and ordering data Dimensions mm × mm Ordering code UI 8PQ4000-0BA04 2 20 × 10, 30 × 10, 40 × 10, 50 × 10 8PQ4000-0BA60 2 20 × 10, 30 × 10, 40 × 10, 50 × 10 8PQ4000-0BA37 1 8PQ9400-0BA21 2 5 Main busbar holder kit up to 3200 A, with PE grounding bar connection to cubicle 01685 20 × 10, 30 × 10, 40 × 10, 50 × 10 01686 Main busbar holder kit up to 4000 A, with PE grounding bar connection to cubicle 01687 Busbar reinforcement kit 02039 Additional internal arc protection kit Siemens LV 56 · 2008 5/5 Busbar System Main busbar system ■ Selection and ordering data Dimensions mm × mm Ordering code UI 01674 Main busbars extension kit for L1, L2, L3, N or PEN1 20 × 10 8PQ4000-0BA53 4 30 × 10 8PQ4000-0BA54 4 40 × 10 8PQ4000-0BA56 4 50 × 10 8PQ4000-0BA57 4 20 × 5, 30 × 5, 30 × 10 8PQ4000-0BA52 2 40 × 5, 40 × 10, 50 × 10 8PQ4000-0BA67 2 8PQ4000-0BA62 1 8PQ4000-0BA12 10 8PQ4000-0BA82 6 01673 Extension kit for PE grounding bar 01790 – PEN jumper for main busbar system1 01706 – PE bar connection to cubicle (accessory) – 01710 5 Connection kit for double main busbar system 1 (order 1 per cubicle; cannot be installed in 400mm wide cubicles) 1) Without screws, washers and nuts. 5/6 Siemens LV 56 · 2008 Busbar System Vertical distribution busbar system Cascaded distribution busbar system with profiled busbars Double arrangement, side-by-side Cascaded distribution busbar system with rectangular bars Double arrangement, aligned 02042 Non-cascaded distribution busbars system with regular busbars Single arrangement 02045 Cascaded distribution busbar system with rectangular bars Single arrangement 02044 02043 Cascaded distribution busbar system with profiled busbars Single arrangement 02041 02040 ■ Overview Non-cascaded distribution busbar system with rectangular bars Double arrangement, aligned Siemens LV 56 · 2008 5/7 5 Busbar System Vertical distribution busbar system ■ Technical specifications Admissible rated current values for cascaded vertical distribution busbars The rated sort-time current Icw for a cascaded vertical busbar system is determined on the basis of no. of busbars, No. of bars per phase Dimensions [mm] Admissible current for a temperature of 35 °C IP ≤ IP41 1 1 2 2 Profiled busbar Profiled busbar 2x2 2x2 2 x Profiled busbar 2 x Profiled busbar 30 × 10 40 × 10 30 × 10 40 × 10 30 × 30 40 × 30 30 × 10 40 × 10 30 × 30 40 × 30 busbar size and shape, and the number of busbar holders. 922 1100 1530 1651 1289 1518 3060 3302 2578 3036 IP 55 837 980 1337 1543 1066 1217 2674 3086 2132 2434 No. of holders per cubicle and per system Icw = 25 kA Ipk = 52,5 kA 4 4 4 4 4 4 Icw = 35 kA Ipk = 73,5 kA 4 4 4 4 4 4 Icw = 50 kA Ipk = 105 kA 4 4 4 4 4 4 4 4 Icw = 65 kA Ipk = 143 kA 5 5 5 5 5 5 5 5 Icw = 85 kA Ipk = 187 kA 8 8 8 8 These values refer to normal operating conditions and indoor installation in accordance with IEC 60439-1, in particular, at an ambient temperature of 35°C (24h average). In different operating conditions, the correction factors given in the “Planning and Configuration” chapter have to be taken into account. 5 Admissible rated current values for non-cascaded vertical distribution busbars The rated sort-time current Icw of a non-cascaded vertical busbar system is determined on the basis of no. of busbars, busbar size, and number of reinforcements. No. of bars per phase Dimensions [mm] Admissible current for a temperature of 35 °C IP ≤ IP41 20 × 10 30 × 10 20 × 10 30 × 10 40 × 10 50 × 10 2 2 4 4 4 4 For each cubicle, order one kit (3 pcs.) of non-cascaded busbar holders. 1010 1390 1630 2091 2533 2737 IP 55 820 1110 1207 1520 1825 1980 No. of reinforcements per cubicle Icw = 25 kA Ipk = 52 kA 0 0 0 0 0 0 Icw = 35 kA Ipk = 73 kA 0 0 0 0 0 0 Icw = 50 kA Icw = 65 kA Icw = 85 kA Icw = 100 kA Ipk = 105 kA Ipk = 143 kA Ipk = 187 kA Ipk = 220 kA 2 2 2 0 0 2 2 2 2 2 2 2 4 4 These values refer to normal operating conditions and indoor installation in accordance with IEC 60439-1, in particular, at an ambient temperature of 35°C (24h average). In different operating conditions, the correction factors given in the “Planning and Configuration” chapter have to be taken into account. 5/8 Siemens LV 56 · 2008 Busbar System Vertical distribution busbar system ■ Configuration Cascaded vertical distribution busbar system For profiled busbars, the connections are made by means of T-head screws. When using rectangular busbars, the connections are made by means of screws and connection kits. ■ Selection and ordering data Busbar dimensions mm × mm Busbar shape Cubicle width mm Cubicle depth mm Position of main busbars Position of vertical distribution busbars Ordering code UI 01690 Busbar holder kit for cascaded vertical distribution busbars 40 × 30 Profiled busbar 200 – – – 8PQ4000-0BA63 4 40 × 10 Rectangular busbar 200 – – – 8PQ4000-0BA63 4 30 × 30 Profiled busbar 200 – – – 8PQ4000-0BA32 4 30 × 10 Rectangular busbar 200 – – – 8PQ4000-0BA32 4 20 × 10, 30 × 10, 40 × 10, 50 × 10 Rectangular busbar 200 – – – 8PQ4000-0BA77 3 20 × 10, 30 × 10, 40 × 10, 50 × 10 Rectangular busbar 400 – – – 8PQ4000-0BA31 3 – – – – 8PQ4000-0BA37 1 01688 Busbar holder kit for non-cascaded vertical distribution busbars Busbar reinforcement kit 01687 20 × 10, 30 × 10, 40 × 10, 50 × 10 Rectangular busbar End support for non-cascaded vertical busbars – 200 – – – 8PQ4000-0BA78 1 – 400 – – – 8PQ4000-0BA61 1 – – – – 8PQ4000-0BA11 4 01689 – – Anchoring support for N or PE bars in cable compartment – 01707 – Siemens LV 56 · 2008 5/9 5 Busbar System Vertical distribution busbar system ■ Selection and ordering data Bus bar dimensions mm × mm Busbar shape Cubicle width mm Cubicle depth mm Position of main busbars Position of vertical distribution busbars Ordering code UI 01718 Connection kit between cascaded vertical busbars/horizontal busbars 1 30 × 30, 30 × 10 – – 400 front right 8PQ4000-0BA45 1 40 × 30, 40 × 10 – – 400 front right 8PQ4000-0BA47 1 30 × 30, 30 × 10 – – 600, 800 front right 8PQ4000-0BA46 1 40 × 30, 40 × 10 – – 600, 800 front right 8PQ4000-0BA48 1 30 × 30, 30 × 10 – – 800 rear right 8PQ4000-0BA50 1 40 × 30, 40 × 10 – – 800 rear right 8PQ4000-0BA51 1 30 × 30, 30 × 10 – – 400 front left 8PQ4000-0BA73 1 40 × 30, 40 × 10 – – 400 front left 8PQ4000-0BA75 1 30 × 30, 30 × 10 – – 600, 800 front left 8PQ4000-0BA72 1 40 × 30, 40 × 10 – – 600, 800 front left 8PQ4000-0BA74 1 30 × 30, 30 × 10 – - 800 rear left 8PQ4000-0BA70 1 40 × 30, 40 × 10 – - 800 rear left 8PQ4000-0BA71 1 Connection kit between non-cascaded vertical busbars/horizontal busbars1 01675 5 20 × 10, 30 × 10 – – 400 front – 8PQ4000-0BA38 1 40 × 10, 50 × 10 – – 400 front – 8PQ4000-0BA41 1 20 × 10, 30 × 10 – – 600, 800 front – 8PQ4000-0BA40 1 40 × 10, 50 × 10 – – 600, 800 front – 8PQ4000-0BA42 1 20 × 10, 30 × 10 – – 800 rear – 8PQ4000-0BA43 1 40 × 10, 50 × 10 – – 800 rear – 8PQ4000-0BA44 1 – – – – – 8PQ9400-0BA02 20 Busbar clamp kit for M10 screw 01743 – 1) without screws, washers and nuts 5/10 Siemens LV 56 · 2008 Busbar System Compact busbar system ■ Overview Compact busbar systems may be arranged as desired with uprights and crossbars. 5 5 4 5 3 2 02047 02046 1 Compact busbar systems 8GF57 non-cascaded, anchored to crossbars 1 Non-cascaded busbar support 2 Cascaded busbar support 3 Crossbars for anchoring width-wise 4 Crossbars for anchoring depth-wise 5 Supporting structure Compact busbar systems 8GF57 cascaded, anchored to crossbars Siemens LV 56 · 2008 5/11 Busbar System Compact busbar system ■ Technical specifications Admissible rated current for copper busbars, for an ambient temperature of 35 °C according to DIN 43671 No. of busbars Rated current at a temperature of Dimensions [mm] 65 °C 85 °C Holder spacing [mm] Icw = 5 kA 105 °C Icw = 10 kA Icw = 15 kA Icw = 20 kA Icw = 25 kA 1 15 × 5 222 293 349 600 400 1 20 × 5 274 362 430 600 600 1 30 × 5 379 500 595 600 600 450 352 300 1 30 × 10 573 756 900 600 600 400 300 250 ■ Description Compact busbar systems are used for the distribution of currents up to 630A and rated short-time currents Icw upto 25 kA. 400 ■ Configuration Compact busbar systems, with pole centre distance of 50mm, can be used in conjunction with the rapid wiring assembly system for modular devices SIKclip. For compact busbar systems, with pole centre distance of 60mm, a wide range of adapters for SIRIUS, SENTRON 3VL is available together with many other accessories. ■ Selection and ordering data Description 5 No. of poles Busbar dimensions mm × mm Busbar shape Arrangement Ordering code UI Busbar holder 4 15 × 5, 20 × 5, 30 × 5 Rectangular non-cascaded 8GF5762 1 Busbar holder 4 30 × 10 Rectangular non-cascaded 8GF5763 1 Busbar holder 4 15 × 5, 20 × 5, 30 × 5 Rectangular cascaded 8GF5760 1 Busbar holder 4 30 × 10 Rectangular cascaded 8GF5761 1 02049 02048 Compact busbar system, 50mm pole centre distance Compact busbar holder system, 60mm pole centre distance 3 15 × 5, 20 × 5, 30 × 5, 30 × 10 Rectangular non-cascaded 8US1923-3AA01 1 Busbar holder 4 15 × 5, 20 × 5, 30 × 5, 30 × 10 Rectangular non-cascaded 8US1923-4AA00 1 Busbar holder end cover 3 – – – 8US1922-1AC00 1 Busbar holder end cover 4 – – – 8US1922-1AB00 1 Busbar cover section – 20 × 5, 30 × 5 Rectangular – 8US1922-2AA00 1 Busbar cover section – 20 × 10, 30 × 10 Rectangular – 8US1922-0BA00 1 Bild 5-9 BUS 2 Bild 5-9 BUS 1 Busbar holder Bild 5-9 BUS 3 5/12 Siemens LV 56 · 2008 Busbar System Copper bars ■ Selection and ordering data Dimensions mm × mm Threading Current A ∆T K Length mm Ordering code UI 15 × 5 M6 – – 2000 8GF5751 1 20 × 5 M6 – – 2000 8GF5737 1 30 × 5 M6 – – 2000 8GF5742 1 40 × 5 for M10 – – 2000 8PQ4000-0BA81 1 60 × 5 for M10 – – 1750 8PQ4000-1BA05 1 80 × 5 for M10 – – 2000 8PQ4000-1BA06 1 100 × 5 for M10 – – 2000 8PQ4000-1BA07 1 30 × 10 for M10 – – 2000 8GF5752 1 40 × 10 for M10 – – 2000 8PQ4000-0BA24 1 20 × 5 – – – 2000 8PQ4000-0BA83 1 30 × 5 – – – 2000 8PQ4000-0BA85 1 40 × 5 – – – 2000 8PQ4000-0BA80 1 15 × 10 – – – 2000 8PQ4000-1BA04 1 20 × 10 – – – 2000 8PQ4000-0BA84 1 30 × 10 – – – 2000 8PQ4000-0BA86 1 40 × 10 – – – 2000 8PQ4000-0BA17 1 50 × 10 – – – 2000 8PQ4000-0BA18 1 60 × 10 – – – 2000 8PQ4000-0BA87 1 80 × 10 – – – 2000 8PQ4000-0BA88 1 100 × 10 – – – 2000 8PQ4000-1BA00 1 120 × 10 – – – 2000 8PQ4000-1BA01 1 01679 Rigid busbar, perforated, with threading 01679 Rigid busbar, perforated 01678 Rigid busbar 01680 PVC insulated flexible busbar 13 × 3 × 0,5 – 160 20 2000 8GF5680 1 13 × 3 × 0,5 – 160 40 2000 8GF5686 1 20 × 5 × 1 – 250 20 2000 8GF5681 1 16 × 4 × 0,8 – 250 40 2000 8GF5687 1 32 × 5 × 1 – 400 20 2000 8GF5682 1 24 × 4 × 1 – 400 40 2000 8GF5688 1 40 × 8 × 1 – 630 20 2000 8GF5683 1 40 × 5 × 1 – 630 40 2000 8GF5690 1 40 × 10 × 1 – 800 30 2000 8PQ4000-1BA03 1 40 × 10 × 1 – 1000 40 2000 8PQ4000-1BA03 1 40 × 10 × 1 – 1250 50 2000 8PQ4000-1BA03 1 50 × 10 × 1 – 1250 20 2000 8PQ4000-1BA02 1 30 × 30 – – – 1610 8PQ4000-0BA27 4 40 × 30 – – – 1610 8PQ4000-0BA26 4 01677 Rigid busbar, H shaped Siemens LV 56 · 2008 5/13 5 Busbar System Fasteners for connections between copper busbars ■ Description ■ Configuration To ensure a reliable connection of the copper busbars, it is important to select quality fasteners, of the right size, suitable and appropriately treated for the task. The table below provides an overview of the various copper busbars - fasteners combination options, so as to facilitate selection and ordering. The stated quantity of fasteners applies to a 4-pole arrangement. Rules for the calculation of the screw length for different busbar dimensions: – Length of screw with M8 threading = busbars profile + 15 mm – Length of screw with M10, M12 threading = busbars profile + 20 mm ■ Selection and ordering data Profile Dimensions mm × mm Quantity Ordering code Description Profiled busbar 30 × 30, 40 × 30 Rectangular busbar 2 × 30 × 10 Rectangular busbar 2 × 40 × 10 Rectangular busbar 2 × 20 × 10, 2 × 40 × 10 Rectangular busbar 4 × 40 × 10, 4 × 50 × 10 Rectangular busbar 2 × 20 × 10, 2 × 30 × 10 4 8 12 12 4 8 8 12 12 4 8 8 12 12 12 12 12 8 8 16 16 8 8 8 2 1 1 1 8PQ9500-0BA14 8PQ9500-0BA01 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA14 8PQ9500-1BA36 8PQ9400-0BA02 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA14 8PQ9500-1BA25 8PQ9400-0BA02 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA14 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA14 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA34 8PQ9500-0BA14 8PQ9500-0BA60 8PQ9500-0BA05 DIN 603 - M10x35 non-cascaded square screw M10x25 T-head screw DIN 6796 10 clamping washer Hexagonal nut ISO 4032 M10 DIN 603 - M10x35 non-cascaded square screw DIN 603 - M10x55 non-cascaded square screw Rail clamp DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x35 non-cascaded square screw DIN 603 - M10x65 non-cascaded square screw Rail clamp DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x35 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x35 non-cascaded square screw DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN7500 - M6x10 self-tapping screw DIN 603 - M10x35 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut 4 8 8 12 12 4 8 8 12 12 4 8 12 12 12 12 12 16 16 16 8 8 8 16 16 16 2 1 1 1 8PQ9500-0BA16 8PQ9500-0BA01 8PQ9400-0BA02 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-1BA36 8PQ9400-0BA02 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-1BA25 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 8PQ9500-0BA34 8PQ9500-0BA16 8PQ9500-0BA60 8PQ9500-0BA05 DIN 603 - M10x45 non-cascaded square screw M10x25 T-head screw Rail clamp DIN 6796 10 clamping washer Hexagonal nut ISO 4032 M10 DIN 603 - M10x45 non-cascaded square screw DIN 603 - M10x55 non-cascaded square screw Rail clamp DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x45 non-cascaded square screw DIN 603 - M10x65 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut DIN7500 - M6x10 self-tapping screw DIN 603 - M10x45 non-cascaded square screw DIN 6796 - 10 clamping washer ISO 4032 - M10 hexagonal nut Main busbar systems with 2 bars per phase Connection from main busbars to: Cascaded vertical busbars 5 Non-cascaded vertical busbars Connection between cubicle and main busbars L1...3, N (PEN) Connection between main busbar PEN ands cubicle PEN (per cubicle) Main busbar systems with 4 bars per phase Connection from main busbars to: Cascaded vertical busbars Non-cascaded vertical busbars Connection between cubicle and main busbars Connection between main busbar PEN and cubicle 5/14 L1...3, N (PEN) Profiled busbar 30 × 30, 40 × 30 Rectangular busbar 2 × 30 × 10 Rectangular busbar 2 × 40 × 10 Rectangular busbar 2 × 20 × 10, 2 × 40 × 10 Rectangular busbar 4 × 40 × 10, 4 × 50 × 10 Rectangular busbar 4 × 20 × 10, 4 × 30 × 10 Rectangular busbar 4 × 40 × 10, 4 × 50 × 10 PEN (per cubicle) Siemens LV 56 · 2008 6 Assembly Kits for Switching Devices 6/2 General Data 6/3 Assembly kit for SENTRON 3WL circuit breakers 6/9 Assembly kit for SENTRON 3VL moulded case circuit breakers 6/20 Assembly kit for SENTRON 3VT moulded case circuit breakers 6/23 Assembly kit for SENTRON 3K disconnectors 6/26 Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ4 6/29 Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ6 6/32 Assembly kit for modular installation devices Siemens LV 56 · 2008 Assembly Kits for Switching Devices General Data ■ Overview 6 1 2 3 4 1 Assembly kit for SENTRON 3WL circuit breakers 2 DIN rail for BETA modular devices 01694 3 Assembly kit for SENTRON 3VL case circuit breakers, horizontal intallation 4 Assembly kit for SENTRON 3VL case circuit breakers, vertical installation 6/2 Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for SENTRON 3WL circuit breakers ■ Overview 2 6 3 7 8 5 4 9 1 11 21 25 19 10 18 22 23 12 6 24 20 13 17 15 14 16 1 Fixed part for draw-out version 14 Emergency stop button, locking key 2 Front attachments, flanged, horizontal, vertical 15 Motorised mechanism 3 Switch position indicator contacts 16 Operation counter 4 Grounding contact 17 Breaker Status Sensor (BSS) 5 Protective louvers 18 Electronic overcurrent release (ETU) 6 PROFIBUS COM 15 communication module 19 Reset solenoid 7 CubicleBUS external modules 20 BDA (Breaker Data Adapter) module 8 Auxiliary disconnectors, closing solenoid 21 4-line LCD display 9 Connector system for auxiliary units 22 Earth fault protection module 10 Auxiliary contact modules 23 Rating Plug 11 Front frame 24 Measuring function module 12 Support for locking devices 25 SENTRON WL circuit breaker 13 Clear cover Siemens LV 56 · 2008 6/3 Assembly Kits for Switching Devices Assembly kit for SENTRON 3WL circuit breakers ■ Technical specifications Switching capacity Size I Type 3WL11 II Switching capacity class N 3WL12 S N S H Rated operating voltage Ue up to AC 415 V Icu kA 55 66 66 80 100 Ics kA 55 66 66 80 100 Icm kA 121 145 145 176 220 Icu kA 55 66 66 80 100 Ics kA 55 66 66 80 100 Icm kA 112 145 145 176 220 Icu kA 42 50 50 75 85 Ics kA 42 50 50 75 85 Icm kA 88 105 105 165 187 Rated operating voltage Ue up to AC 500 V Rated operating voltage Ue up to AC 690 V Rated operating voltage Ue up to AC 1000 V 6 Icu kA – – – – 45 Ics kA – – – – 45 Icm kA – – – – 95 Rated short-time current Icw of circuit breaker Size I Type 3WL11 Switching capacity class N S II 3WL12 N S H 0,5 s kA 50 66 66 80 100 1s kA 42 50 55 66 80 2s kA 29,5 35 39 46 501)/562) 3s kA 24 29 32 37 401)/502) Rated short-circuit current Icc of circuit breaker Size I Type 3WL11 II Switching capacity class N S 3WL12 N S H up to AC 500 V kA 50 66 66 80 100 up to AC 690 V kA 42 50 50 75 85 1) Size II with In max ≤ 2500 A. 2) Size II with In max ≤ 3200 A. Size I Type up to 3WL11 12 3WL11 16 3WL12 08 3WL12 10 3WL12 12 3WL12 16 3WL12 20 3WL12 25 3WL12 32 3WL11 10 Minimum phase size II Busbars, Cu, piece 1× 2× 2× 1× 1× 2× 2× 3× 2× 3× bare mm2 60 × 10 40 × 10 50 × 10 50 × 10 60 × 10 40 × 10 50 × 10 50 × 10 100 × 10 100 × 10 Busbars, Cu piece 1× 2× 2× 1× 1× 2× 2× 3× 2× 3× insulated, black mm2 60 × 10 40 × 10 50 × 10 50 × 10 60 × 10 40 × 10 50 × 10 50 × 10 100 × 10 100 × 10 For further information, see the technical documents on SENTRON 3WL 6/4 II Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for SENTRON 3WL circuit breakers ■ Description ■ Configuration The assembly kit for SENTRON 3WL circuit breakers is made up of: • Mounting plate • Crossbars • Cover with cut-out and fast closing screws (designed for the installation of the Sentron 3WL with cover frame) • Separation partition • Fasteners The assembly kits for Sentron 3WL circuit breakers are suitable for currents of up to 3200 A. The horizontal plate is suitable for the installation of circuit breakers, in fixed and draw out versions of different sizes. Horizontal separation ensures the required arcing spaces. The cover has a cut-out to fit the relative frame 3WL 91110AP01-0AA0. The Sentron 3WL 1240 circuit breaker can be installed only in 800mm deep cubicles. The assembly kit for Sentron 3WL circuit breakers can be installed only in 600mm and 800mm deep cubicles. ■ Selection and ordering data No. of poles Width mm Module height mm Mounting plate SENTRON 3WL Cover SENTRON 3WL 02051 02050 Size Assembly kit for Sentron 3WL, in fixed and draw out versions BG I, BG II 3 600 550 8PQ6000-3BA31 8PQ2055-6BA05 BG I 4 600 550 8PQ6000-3BA31 8PQ2055-6BA07 BG I 3/4 800 550 8PQ6000-3BA32 8PQ2055-8BA04 BG II 3 800 550 8PQ6000-3BA32 8PQ2055-8BA07 BG II 4 800 550 8PQ6000-3BA32 8PQ2055-8BA05 ■ Description ■ Configuration The support kit consists of a strip in fibreglass reinforced plastic sized 25x25mm and the relative fasteners to secure it to the cubicle or to the side upright. The distance between the circuit breaker terminal bar and the support and the distance between two supports is ≤ 100mm. ■ Selection and ordering data No. of poles Width mm Support Ordering code UI 02057 Size Support for Sentron 3WL, in fixed and draw out versions BG I 3/4 600 8PQ6000-4BA35 4 BG II 3 600 8PQ6000-4BA36 4 BG I 3/4 800 8PQ6000-4BA37 4 BG II 3/4 800 8PQ6000-4BA38 4 Siemens LV 56 · 2008 6/5 6 Assembly Kits for Switching Devices Assembly kit for SENTRON 3WL circuit breakers ■ Description ■ Configuration The support kit is made up of crossbars, corner pieces and the fasteners to secure the support to the structure or the side upright. For the arrangement of supports in standard position in the SIVACON S4 system, see chapter 11 “Dimensions”. The connection of distribution busbars is not included in the kit. The busbars must be mounted by the board installation technician. ■ Selection and ordering data No. of poles Width mm Support Ordering code UI NSE0_02058 Size Support for busbar connection kit for Sentron 3WL, in fixed and draw out versions BG I 3,4 600 8PQ3000-1BA70 BG II 3 600 8PQ3000-1BA70 1 BG I, BG II 3,4 800 8PQ3000-1BA71 1 02211 6 Support busway connection SIVACON 8PS 6/6 Siemens LV 56 · 2008 1 Assembly Kits for Switching Devices Assembly kit for SENTRON 3WL circuit breakers ■ Description ■ Configuration The connections to SIVACON 8PS busways are optimised for the connection of Sentron 3WL circuit breakers in the SIVACON S4 system. It is important to select the correct combination of circuit breaker, busway connection and busway. ■ Selection and ordering data Sentron 3WL GR I Sentron 3WL GR II Sentron 3WL GR I Sentron 3WL GR II Busway connection Ordering code Conductor configuration Suitable for busways In [A] Suitable for busways In [A] Suitable for busways In [A] BVP:660299 100% PEN LDA3423(5)-... 1600 LDA2423(5)-... 1250 LDA1423(5)-... 1100 BVP:660300 100% N LDA3623(5)-... 1600 LDA2623(5)-... 1250 LDA1623(5)-... 1100 BVP:660301 100% PEN LDA4423(5)-... 2000 – – BVP:660302 100% N LDA2623(5)-... 2000 – – BVP:660303 100% PEN LDA3423(5)-... 2600 LDA2423(5)-... 2000 – BVP:660304 100% N LDA3623(5)-... 2600 LDA2623(5)-... 2000 – BVP:660305 50% PEN LDA6413(5)-... 3000 LDA5413(5)-... 2500 LDA4413(5)-... 2000 BVP:660306 100% PEN LDA6423(5)-... 3000 LDA5423(5)-... 2500 LDA4423(5)-... 2000 BVP:660307 50% N 50% PE LDA6613(5)-... 3000 LDA5613(5)-... 2500 LDA4613(5)-... 2000 BVP:660308 100% N 50% PE LDA6623(5)-... 3000 LDA5623(5)-... 2500 LDA4623(5)-... 2000 BVP:660309 50% PEN LDA6413(5)-... 3400 – – BVP:660310 100% PEN LDA6423(5)-... 3400 – – BVP:660311 50% N 50% PE LDA6613(5)-... 3400 – – BVP:660312 100% N 50% PE LDA6623(5)-... 3400 – – Busway connection Ordering code Conductor configuration Suitable for busways In [A] Suitable for busways In [A] Suitable for busways In [A] Suitable for busways In [A] Suitable for busways In [A] BVP:660321 100% PEN LXC0341-... 1400 LXC0141-... 1000 LXA0141-... 800 – – BVP:660322 100% N LXC0351-... 1400 LXC0151-... 1000 LXA0151-... 800 – – BVP:660323 100% PEN LXA0541-... 1600 LXC0441-... 1600 LXA0441-... 1250 LXC0241-... 1250 LXA0241-... 1000 BVP:660324 100% N BVP:660325 100% PEN BVP:660326 100% N BVP:660327 100% PEN BVP:660328 100% N BVP:660329 100% PEN BVP:660330 100% N BVP:660331 100% PEN BVP:660332 100% N BVP:660333 100% PEN BVP:660334 100% N 100% PE 100% PE 100% PE 100% PE 100% PE 100% PE 100% PE 100% PE 100% PE 100% PE 6 LXA0551-... 1600 LXC0451-... 1600 LXA0451-... 1250 LXC0251-... 1250 LXA0251-... 1000 LXA0641-... 2000 LXC0541-... 2000 – – – LXA0651-... 2000 LXC0551-... 2000 – – – LXC0641-... 2500 – – – – LXC0651-... 2500 – – – – LXA0741-... 2500 – – – – LXA0751-... 2500 – – – – LXC0741-... 3200 – – – – LXC0751-... 3200 – – – – LXA0841-... 3200 – – – – LXA0851-... 3200 – – – – Siemens LV 56 · 2008 6/7 Assembly Kits for Switching Devices Assembly kit for SENTRON 3WL circuit breakers ■ Description ■ Configuration The prefabricated Cu busbar kit for Sentron 3WL circuit breakers is made up of: • Crossbars • Support • Reinforcement • Copper busbars • Protective isolation shield • Fasteners The Cu connecting busbar kit for Sentron 3WL circuit breakers going to the cable connection system occupies the heights of the module specified above or below the circuit breaker. With the cable entry variants and connection to the vertical distribution busbars variants, the system offers connection kits type tested in terms of CT mounting and number of connection points, in cascaded form, for the respective circuit breaker rated currents. Through the combination of variants it is possible to achieve functions such as incomer, outgoing and coupler. Construction of connecting busbars for Sentron 3WL circuit breakers with flanged terminal bars for draw out versions. To be able to anchor, bend and connect the cables it is necessary to leave enough space for the assembly operations. Construction of connecting busbars for Sentron 3WL circuit breakers with horizontal rear terminal bars for fixed versions. ■ Selection and ordering data Module height Size Current No. of poles Version Width mm above the breaker mm below the breaker mm Ordering code UI 300 300 300 300 350 350 350 350 8PQ6000-0BA34 8PQ6000-0BA33 8PQ6000-2BA45 8PQ6000-2BA44 8PQ6000-0BA41 8PQ6000-0BA40 8PQ6000-0BA47 8PQ6000-0BA46 1 1 1 1 1 1 1 1 250 250 250 250 400 400 400 400 8PQ6000-0BA52 8PQ6000-0BA51 8PQ6000-2BA47 8PQ6000-2BA46 8PQ6000-0BA58 8PQ6000-0BA57 8PQ6000-0BA65 8PQ6000-0BA64 1 1 1 1 1 1 1 1 Kit of prefabricated busbars for Sentron 3WL for connection to the vertical bars, cascaded 1600A 1600A 1600A 1600A 2000A 2000A 3200A 3200A 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Fixed Draw out Fixed Draw out Fixed Draw out Fixed Draw out 600 600 800 800 800 800 800 800 250 250 250 250 300 300 300 300 Kit of prefabricated busbars for Sentron 3WL for connection to the connecting cables 1600A 1600A 1600A 1600A 2000A 2000A 3200A 3200A 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 Fixed Draw out Fixed Draw out Fixed Draw out Fixed Draw out 600 600 800 800 800 800 800 800 200 200 200 200 350 350 350 350 02055 BG I BG I BG I BG I BG II BG II BG II BG II 02054 6 BG I BG I BG I BG I BG II BG II BG II BG II Sentron 3WL with horizontal rear terminal bars, for fixed version 6/8 Siemens LV 56 · 2008 Sentron 3WL with flanges, for draw out version Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breakers ■ Overview 9 10 8 2 3 11 10 4 5 6 7 1 14 12 21 15 20 18 17 16 13 4 5 19 6 6 7 3 8 9 1 Fixed part for plugin version 12 Direct rotary operating mechanism 2 Side panels for draw out version 13 Door locking rotary operating mechanism 3 Phase separators 14 SENTRON VL circuit breaker 4 Front terminal bars, divergent 15 Internal accessories 5 Front terminal bars, straight 16 Electronic overcurrent release 6 Terminals for Al/Cu cables 17 Thermal/magnetic overcurrent release 7 Terminals for copper cables and busbars 18 DI module - RCD 8 Terminal cover, extended 19 Rear connections - flat and round 9 Terminal cover, standard 20 COM 10 PROFIBUS-DP communication module 10 Front frame 21 Handheld testing device 11 Motorised operating mechanism with spring accumulator Siemens LV 56 · 2008 6/9 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breakers ■ Technical specifications VL 160X 3VL1 Type VL 160 3VL2 VL 250 3VL3 VL 400 3VL4 VL 630 3VL5 VL 800 3VL6 VL 1250 3VL7 VL 1600 3VL8 Connection dimensions and types for main circuits Box terminals mm2 2,5-95 2,5-95 25-185 50-300 – – – – Flexible wire with sleeve connector mm2 2,5-50 2,5-50 25-120 50-240 – – – – Busbar mm 12 × 10 12 × 10 17 × 10 25 × 10 – – – – Clamp for flexible bar mm – – – – 2 pieces 6 × 32 – – – mm2 16-70 16-70 25-185 50-300 – – – – mm2 10-50 10-50 25-120 50-240 – – – – mm2 – – – 2 pieces 50-120 2 pieces 50-240 3 pieces 50-240 4 pieces 50-240 – mm2 – – – 2 pieces 50-95 2 pieces 50-185 3 pieces 50-185 4 pieces 50-185 – mm 17 × 7 22 × 7 24 × 7 32 × 10 40 × 10 2 × 40 × 10 2 × 50 × 10 3 × 60 × 10 M5 M5 M8 M8 M6 M8 Single- or multi-wire cable only copper Power supply terminals with multiple cables Single- or multi-wire cable copper or Al Flexible wire with sleeve connector Multiple feed-in terminal Power supply terminals for cables copper or Al Flexible wire with end terminal Direct busbar connection Screw type for screwed connection 6 6/10 Siemens LV 56 · 2008 copper or Al M8 – Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, horizontal installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanisms. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). Hinges to be fitted to the individual covers are available as an option. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides the internal separation for a branch unit. For horizontal installation and front connections, extended terminal covers have to be ordered. A combination of front frame and covers with modular doors in a cubicle is not possible. ■ Selection and ordering data Cover with cut-out for type of op. mechanism Height mm Width mm Depth1 Max no. of circuit mm breakers Link-N support Equipment mounting plate Cover 02059 02060 No. Connection of poles 02064 Circuit breaker Sentron 3VL moulded case circuit breakers, fixed, horizontal installation VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 VL 800 VL 800 3 4 3 4 3 4 3 4 3 4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear rear rear Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. 150 200 150 200 200 250 300 350 300 350 600 600 600 600 600 600 600 600 600 600 ■ Description 400 400 400 400 400 400 400 400 400 400 1 1 1 1 1 1 1 1 1 1 8PQ6000-3BA52 8PQ6000-3BA52 8PQ6000-3BA53 8PQ6000-3BA54 8PQ6000-2BA74 8PQ6000-2BA80 8PQ6000-3BA13 8PQ6000-3BA18 8PQ6000-2BA84 8PQ6000-2BA87 8PQ6000-3BA01 8PQ6000-3BA10 8PQ6000-3BA08 8PQ6000-4BA16 8PQ2015-6BA03 8PQ2020-6BA04 8PQ2015-6BA03 8PQ2020-6BA04 8PQ2020-6BA06 8PQ2025-6BA02 8PQ2030-6BA03 8PQ2035-6BA04 8PQ2030-6BA02 8PQ2035-6BA05 ■ Configuration The prefabricated Cu busbar kit for Sentron 3VL moulded case circuit breakers for horizontal installation is made up of: • Crossbars • Support • Plastic reinforcement • Copper busbars • Protective isolation shield • Fastening screws With the cable entry variants and connection to the vertical distribution busbars variants, the system offers connection kits type-tested in terms of CT mounting and number of connection points to the busbars, in cascaded form, for the respective circuit breaker rated currents. The height of the connecting busbars kit matches the type of circuit breaker. The connecting busbar kit is suitable for branch units without differential module. In addition to the copper busbars and the cover, the “connecting busbar” kit for Sentron VL circuit breakers for connection to the cables contains lateral partitions with connecting terminals. When fitting connecting busbar kit for Sentron VL circuit breakers for connection to the cascaded vertical busbars in a 600 mm cubicle, the vertical distribution busbar system must be housed in the same cubicle (800 mm cubicle with riser compartment 600 + 200 mm). ■ Selection and ordering data Circuit breaker No. of poles Version Ad hoc covers for type of op. mech. Max. no. of switches Height of module mm Width mm Ordering code UI 1 01652 Kit of connecting bars for Sentron 3VL for connection to cascaded vertical distribution bars VL 250 3 fixed direct 1 150 600 8PQ6000-1BA63 VL 250 4 fixed direct 1 200 600 8PQ6000-1BA64 1 VL 400 3 fixed direct 1 200 600 8PQ6000-1BA65 1 VL 400 4 fixed direct 1 250 600 8PQ6000-1BA66 1 VL 630 3 fixed direct 1 300 600 8PQ6000-1BA67 1 VL 630 4 fixed direct 1 350 600 8PQ6000-1BA68 1 1 01653 Kit of connecting bars for Sentron 3VL for connection to the cables 1 VL 250 3 fixed direct 1 150 600 8PQ6000-1BA70 VL 250 4 fixed direct 1 200 600 8PQ6000-1BA71 1 VL 400 3 fixed direct 1 200 600 8PQ6000-1BA72 1 VL 400 4 fixed direct 1 250 600 8PQ6000-1BA73 1 VL 630 3 fixed direct 1 300 600 8PQ6000-1BA74 1 VL 630 4 fixed direct 1 350 600 8PQ6000-1BA75 1 minimum depth Siemens LV 56 · 2008 6/11 6 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for horizontal installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For horizontal installation and front connections, extended terminal covers have to be ordered. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanisms. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). To improve the stability of the kits for VL 400 and 630 in plug-in version it is necessary to fit a reinforcement kit for each branch unit. Hinges to be fitted to the individual covers are available as an option. A combination of front frame and covers with modular doors in a cubicle is not possible. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. ■ Selection and ordering data Height of Width Depth module mm mm mm Max. no. N-Link support of circuit breakers Equipment mounting plate Cover 02060 Ad hoc cover for type of op. mech. 02059 No. Connecof tion poles 02064 Circuit breaker Sentron 3VL moulded case circuit breakers, plug-in, for horizontal installation VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 400 VL 400 VL 630 VL 630 VL 630 VL 630 6 1 3 4 3 4 3 3 4 4 3 3 4 4 front, rear front, rear front, rear front, rear front rear front rear front rear front rear Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Minimum depth 6/12 Siemens LV 56 · 2008 150 200 150 200 200 200 250 250 300 300 350 350 600 600 600 600 600 600 600 600 600 600 600 600 400 400 400 400 400 600/800 400 600/800 400 600/800 400 600/800 1 1 1 1 1 1 8PQ6000-3BA52 8PQ6000-3BA52 8PQ6000-3BA53 8PQ6000-3BA53 1 1 1 1 8PQ6000-3BA54 8PQ6000-3BA54 8PQ6000-3BA24 8PQ6000-3BA27 8PQ6000-3BA24 8PQ6000-3BA27 8PQ6000-2BA84 8PQ6000-2BA84 8PQ6000-2BA87 8PQ6000-2BA87 8PQ6000-3BA01 8PQ6000-3BA01 8PQ6000-3BA10 8PQ6000-3BA10 8PQ2015-6BA03 8PQ2020-6BA04 8PQ2015-6BA03 8PQ2020-6BA04 8PQ2020-6BA06 8PQ2020-6BA06 8PQ2025-6BA02 8PQ2025-6BA02 8PQ2030-6BA03 8PQ2030-6BA03 8PQ2035-6BA04 8PQ2035-6BA04 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for horizontal installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanisms. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). Hinges to be fitted to the individual covers are available as an option. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. For horizontal installation and front connections, extended terminal covers have to be ordered. A combination of front frame and covers with modular doors in a cubicle is not possible. ■ Selection and ordering data Ad hoc cover for type of op. mech. Height of Width Depth1 Max. no. module mm mm of circuit mm breakers Equipment mounting plate Cover 02140 No. of Connecpoles tion 02059 Circuit breaker Sentron 3VL moulded case circuit breaker, draw out, for horizontal installation front, rear front, rear front, rear front, rear 3/4 3/4 3 4 Circuit breaker No. of Connecpoles tion Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. 250 300 300 350 Ad hoc cover for type of op. mech. Height of Width Depth1 Max. no. module mm mm of circuit mm breakers 600 600 600 600 400 400 400 400 1 1 1 1 8PQ6000-3BA27 8PQ6000-2BA87 8PQ6000-3BA01 8PQ6000-3BA10 8PQ2020-6BA21 8PQ2025-6BA11 8PQ2030-6BA17 8PQ2035-6BA17 Reinforcement 02139 VL 160/250 VL 400 VL 630 VL 630 Reinforcement per Sentron 3VL circuit breaker kit, draw out, horizontal installation Circuit breaker No. of Connecpoles tion Ad hoc cover for type of op. mech. 400 400 400 1 1 1 8PQ6000-4BA17 8PQ6000-4BA20 8PQ6000-4BA18 Height of Width Depth1 Max. no. N-Link module mm mm of circuit mm breakers Equipment mounting plate Cover 02063 600 600 600 02062 3/4 3 4 02064 VL 400 VL 630 VL 630 Sentron 3VL compact moulded case circuit breaker with RCD, with fixed mounting technology, mounted horizontally No. of Connecpoles tion Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Ad hoc cover for type of op. mech. 150 200 150 200 600 600 600 600 400 400 400 400 1 1 1 1 8PQ6000-3BA52 8PQ6000-3BA52 Height of Width Depth1 Max. no. N-Link module mm mm of circuit mm breakers 8PQ6000-2BA73 8PQ6000-2BA78 8PQ6000-3BA14 8PQ6000-3BA20 8PQ2015-6BA05 8PQ2020-6BA08 8PQ2015-6BA04 8PQ2020-6BA05 Equipment mounting plate Cover 02063 front, rear front, rear front rear 02064 Circuit breaker 3 4 3 4 02062 VL 160X VL 160X VL 160/250 VL 160/250 Sentron 3VL compact moulded case circuit breaker, with plug-in technology, mounted horizontally VL 160X VL 160X VL 160/250 VL 160/250 1 Minimum depth 3 4 3 4 front, rear front, rear fron rear Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. 150 200 150 200 600 600 600 600 400 400 400 400 1 1 1 1 8PQ6000-3BA52 8PQ6000-3BA52 8PQ6000-2BA75 8PQ6000-2BA81 8PQ6000-2BA75 8PQ6000-2BA81 8PQ2015-6BA06 8PQ2020-6BA07 8PQ2015-6BA04 8PQ2020-6BA05 Siemens LV 56 · 2008 6/13 6 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for horizontal installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For horizontal installation and front connections, extended terminal covers have to be ordered. The modular doors kit with degree of protection IP4X with holes for the 8UC door locking mechanism contains a door, hinges, individual cover and fasteners. A combination of front frame and covers with modular doors in a cubicle is not possible. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. For a degree of protection IP55 an upgrade to IP55 is available (see chapter 7, modular doors). a Due to the length of the operating mechanism, an height 50mm module above the assembly kit should be provided for at the design stage. ■ Selection and ordering data Height of Width Depth1 module mm mm mm Max. no. N-Link support of circuit breakers Equipment mounting plate Modular door 02061 Ad hoc cover for type of op. mech. 02059 No. of Connecpoles tion 02064 Circuit breaker Sentron 3VL moulded case circuit breaker, fixed, for horizontal installation VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 VL 800 VL 800 6 3 4 3 4 a 3 4 3 4 3 4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear rear rear 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 150 200 150 200 200 250 300 350 300 350 Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm 600 600 600 600 600 600 600 600 600 600 400 400 400 400 400 400 400 400 400 400 1 1 1 1 1 1 1 1 1 1 8PQ6000-3BA52 8PQ6000-3BA52 8PQ6000-3BA53 8PQ6000-3BA54 8PQ6000-2BA74 8PQ6000-2BA80 8PQ6000-3BA13 8PQ6000-3BA18 8PQ6000-2BA84 8PQ6000-2BA87 8PQ6000-3BA01 8PQ6000-3BA10 8PQ6000-3BA08 8PQ6000-4BA16 8PQ2015-6BA14 8PQ2020-6BA16 8PQ2015-6BA14 8PQ2020-6BA16 8PQ2020-6BA20 8PQ2025-6BA10 8PQ2030-6BA15 8PQ2035-6BA15 8PQ2030-6BA16 8PQ2035-6BA16 Equipment mounting plate Modular door Max. no. N-Link support of circuit breakers 02061 No. of Connecpoles tion 02064 Circuit breaker 02059 ■ Selection and ordering data Sentron 3VL moulded case circuit breaker, plug-in, for horizontal installation VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 1 3 4 3 4 a 3 4 3 4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 Minimum depth 6/14 Siemens LV 56 · 2008 150 200 150 200 200 250 300 350 600 600 600 600 600 600 600 600 400 400 400 400 400 400 400 400 1 1 1 1 1 1 1 1 8PQ6000-3BA52 8PQ6000-3BA52 8PQ6000-3BA53 8PQ6000-3BA54 8PQ6000-3BA24 8PQ6000-3BA27 8PQ6000-3BA24 8PQ6000-3BA27 8PQ6000-2BA84 8PQ6000-2BA87 8PQ6000-3BA01 8PQ6000-3BA10 8PQ2015-6BA14 8PQ2020-6BA16 8PQ2015-6BA14 8PQ2020-6BA16 8PQ2020-6BA20 8PQ2025-6BA10 8PQ2030-6BA15 8PQ2035-6BA15 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for horizontal installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For horizontal installation and front connections, extended terminal covers have to be ordered. The modular doors kit with degree of protection IP4X with holes for the 8UC door locking mechanism contains a door, hinges, individual cover and fasteners. A combination of front frame and covers with modular doors in a cubicle is not possible. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. For a degree of protection IP55 an upgrade to IP55 is available (see chapter 7, modular doors). ■ Selection and ordering data Height of Width Depth1 module mm mm mm Max. no. N-Link support of circuit breakers Equipment mounting plate Modular door 02061 Ad hoc cover for type of op. mech. 02062 No. of Connecpoles tion 02064 Circuit breaker Sentron 3VL moulded case circuit breaker with differential module, fixed, for horizontal installation VL 160/250 VL 160/250 3 4 front, rear front, rear 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 150 200 Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm 600 600 400 400 1 1 8PQ6000-3BA52 8PQ6000-3BA14 8PQ6000-3BA20 8PQ2015-6BA16 8PQ2020-6BA17 Equipment mounting plate Modular door Max. no. N-Link support of circuit breakers 02061 No. of Connecpoles tion 02064 Circuit breaker 02062 ■ Selection and ordering data Sentron 3VL moulded case circuit breaker with differential module, plug-in, for horizontal installation VL 160/250 VL 160/250 1 Minimum depth 3 4 front, rear front, rear 8UC-door locking mech., Gr. 2 8UC-door locking mech., Gr. 2 150 200 600 600 400 400 1 1 8PQ6000-3BA52 8PQ6000-2BA75 8PQ6000-2BA81 8PQ2015-6BA16 8PQ2020-6BA17 Siemens LV 56 · 2008 6/15 6 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for vertical installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. Shielding is provided for the motorised operating mechanism with spring accumulator. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanism. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). For circuit breaker, base or rack and motorised operating mechanism combinations, take into due account the indications given in the dimensional drawings 11/15. Hinges to be fitted to the individual covers are available as an option. b For front terminal bars, two additional covers, height 100mm each, are required. Moreover, extended terminal covers have to be ordered for the respective circuit breaker. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. ■ Selection and ordering data Height of Width Depth1 module mm mm mm Max. no. N-Link support of circuit breakers Equipment mounting plate Cover 02066 Ad hoc cover for type of op. mech. 02065 No. of Connecpoles tion 02070 Circuit breaker Sentron 3VL moulded case circuit breaker, fixed, for vertical installation VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 6 b b b b b b b b 3 4 3 4 3 4 3/4 3 3 4 3 4 3 4 3 4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. 350 350 350 350 400 400 400 400 350 350 350 350 400 400 400 400 Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm 600 600 600 600 600 600 600 600 800 800 800 800 800 800 800 800 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 1-4 1-3 1-4 1-3 1-3 1-2 1 1-2 1-5 1-4 1-5 1-4 1-4 1-3 1-3 1-2 8PQ6000-3BA54 8PQ6000-2BA76 8PQ6000-2BA82 8PQ6000-3BA16 8PQ6000-3BA22 8PQ6000-2BA85 8PQ6000-2BA88 8PQ6000-3BA05 8PQ6000-3BA02 8PQ6000-2BA77 8PQ6000-2BA83 8PQ6000-3BA17 8PQ6000-3BA23 8PQ6000-2BA86 8PQ6000-3BA00 8PQ6000-3BA03 8PQ6000-3BA06 8PQ2035-6BA02 8PQ2035-6BA03 8PQ2035-6BA02 8PQ2035-6BA03 8PQ2040-6BA07 8PQ2040-6BA05 8PQ2040-6BA08 8PQ2040-6BA06 8PQ2035-8BA02 8PQ2035-8BA03 8PQ2035-8BA02 8PQ2035-8BA03 8PQ2040-8BA08 8PQ2040-8BA07 8PQ2040-8BA06 8PQ2040-8BA05 Equipment mounting plate Cover Max. no. N-Link support of circuit breakers 02066 No. of Connecpoles tion 02070 Circuit breaker 02141 ■ Selection and ordering data Sentron 3VL moulded case circuit breaker, fixed, for vertical installation VL 800 VL 1250 VL 1600 1 b 3/4 b 3/4 b 3/4 front, rear front, rear front, rear Direct, mot. rotary front mech. 600 Direct, mot. rotary front mech. 600 Direct, mot. rotary front mech. 700 Minimum depth 6/16 Siemens LV 56 · 2008 600 600 600 400 400 400 1 1 1 8PQ6000-3BA55 8PQ6000-3BA56 8PQ6000-3BA56 8PQ6000-3BA07 8PQ6000-3BA11 8PQ6000-3BA12 8PQ2060-6BA02 8PQ2060-6BA03 8PQ2070-6BA01 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for vertical installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanism. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). a For front terminal bars, two additional covers, H50mm each, are required. Moreover, extended terminal covers have to be ordered for the respective circuit breaker. b For front terminal bars, two additional covers, H100mm each, are required. Moreover, extended terminal covers have to be ordered for the respective circuit breaker. Hinges to be fitted to the individual covers are available as an option. Shielding is provided for the motorised operating mechanism with spring accumulator. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. For circuit breaker, base or rack and motorised operating mechanism combinations, take into due account the indications given in the dimensional drawings 11/15. ■ Selection and ordering data Height of Width Depth1 module mm mm mm Max. no. N-Link support of circuit breakers Equipment mounting plate Cover 02066 Ad hoc cover for type of op. mech. 02065 No. of Connecpoles tion 02070 Circuit breaker Sentron 3VL moulded case circuit breaker, plug-in, for vertical installation VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 VL 160X VL 160X VL 160/250 VL 160/250 VL 400 VL 400 VL 630 VL 630 1 a a a a b b b b a a a a b b b b Minimum depth 3 4 3 4 3 4 3/4 3 3 4 3 4 3 4 3 4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. Direct, mot. rotary front mech. 350 350 350 350 400 400 400 400 350 350 350 350 400 400 400 400 600 600 600 600 600 600 600 600 800 800 800 800 800 800 800 800 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 1-4 1-3 1-4 1-3 1-3 1-2 1 1-2 1-5 1-4 1-5 1-4 1-4 1-3 1-3 1-2 8PQ6000-3BA54 8PQ6000-3BA25 8PQ6000-3BA28 8PQ6000-3BA25 8PQ6000-3BA28 8PQ6000-2BA85 8PQ6000-2BA88 8PQ6000-3BA05 8PQ6000-3BA02 8PQ6000-3BA26 8PQ6000-3BA30 8PQ6000-3BA26 8PQ6000-3BA30 8PQ6000-2BA86 8PQ6000-3BA00 8PQ6000-3BA03 8PQ6000-3BA06 8PQ2035-6BA02 8PQ2035-6BA03 8PQ2035-6BA02 8PQ2035-6BA03 8PQ2040-6BA07 8PQ2040-6BA05 8PQ2040-6BA08 8PQ2040-6BA06 8PQ2035-8BA02 8PQ2035-8BA03 8PQ2035-8BA02 8PQ2035-8BA03 8PQ2040-8BA08 8PQ2040-8BA07 8PQ2040-8BA06 8PQ2040-8BA05 Siemens LV 56 · 2008 6/17 6 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for vertical installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanism. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). Hinges to be fitted to the individual covers are available as an option. For circuit breaker, base or rack and motorised operating mechanism combinations, take into due account the indications given in the dimensional drawings 11/15. a For front terminal bars, two additional covers, height 50mm each, are required. Moreover, extended terminal covers have to be ordered for the respective circuit breaker. b For front terminal bars, two additional covers, height 100mm each, are required. Moreover, extended terminal covers have to be ordered for the respective circuit breaker. ■ Selection and ordering data Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm Max. no. of circuit breakers Equipment mounting plate Cover 1 1 1-3 1-2 1-2 1 1 8PQ6000-2BA88 8PQ6000-3BA05 8PQ6000-3BA26 8PQ6000-3BA30 8PQ6000-2BA86 8PQ6000-3BA00 8PQ6000-3BA06 8PQ2040-6BA17 8PQ2060-6BA12 8PQ2035-8BA08 8PQ2040-8BA15 8PQ2040-8BA16 8PQ2040-8BA17 8PQ2040-8BA20 Max. no. of circuit breakers Equipment mounting plate Cover 1 1 1 1 8PQ6000-3BA87 8PQ6000-3BA88 8PQ6000-4BA00 8PQ6000-4BA01 02067 No. of Connection poles 02065 Circuit breaker Sentron 3VL moulded case circuit breaker, draw out, for vertical installation VL 400 VL 630 VL 160/250 VL 160/250 VL 400 VL 400 VL 630 6 b b a a b b b 3/4 3/4 3 4 3 4 3/4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear Direct, rotary front Direct, rotary front Direct, rotary front Direct, rotary front Direct, rotary front Direct, rotary front Direct, rotary front 400 400 350 350 400 400 400 600 600 800 800 800 800 800 400 400 400 400 400 400 400 No. of Connection poles Ad hoc cover for type of op. mech. Height of Breite Depth1 module mm mm mm 02068 Circuit breaker 02069 ■ Selection and ordering data Sentron 3VL moulded case circuit breaker, draw out, vertical installation VL 800 VL 800 VL 1250/1600 VL 1250/1600 1 b b b b 3 4 3 4 front, rear front, rear front, rear front, rear Minimum depth 6/18 Siemens LV 56 · 2008 Direct Direct Direct Direct 600 600 650 650 600 600 600 600 600/800 600/800 600/800 600/800 8PQ2060-6BA13 8PQ2060-6BA14 8PQ2065-6BA05 8PQ2065-6BA06 Assembly Kits for Switching Devices Assembly kit for SENTRON 3VL moulded case circuit breaker, for vertical installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. Extended terminal covers have to be ordered for front terminal bars. The modular doors kit with degree of protection IP4X with holes for the 8UC door locking mechanism contains a door, hinges, individual cover and fasteners. The Link-N kit includes support, cover and fasteners. In the 3and 4-pole moulded case circuit breaker combination this kit provides for the internal separation for a branch unit. ■ Selection and ordering data Height of Width module mm mm Depth1 mm Max. no. N-Link support of circuit breakers Equipment mounting plate Cover 02061 Ad hoc cover for type of op. mech. 02065 No. of Connecpoles tion 02070 Circuit breaker Sentron 3VL moulded case circuit breakers, plug-in, for horizontal installation VL 630 VL 630 VL 800 VL 800 VL 1250 VL 1250 VL 1600 VL 1600 1 Minimum depth 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 rear front rear front rear front rear front 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 8UC-door locking mech., Gr. 3 400 600 600 800 600 800 700 900 600 600 600 600 600 600 600 600 400 400 400 400 400 400 400 400 1 1 1 1 1 1 1 1 8PQ6000-3BA54 8PQ6000-3BA54 8PQ6000-3BA55 8PQ6000-3BA55 8PQ6000-3BA56 8PQ6000-3BA56 8PQ6000-3BA56 8PQ6000-3BA56 8PQ6000-3BA05 8PQ6000-3BA05 8PQ6000-3BA07 8PQ6000-3BA07 8PQ6000-3BA11 8PQ6000-3BA11 8PQ6000-3BA12 8PQ6000-3BA12 8PQ2040-6BA16 8PQ2060-6BA17 8PQ2060-6BA10 8PQ2080-6BA05 8PQ2060-6BA11 8PQ2080-6BA06 8PQ2070-6BA02 8PQ2090-6BA01 Siemens LV 56 · 2008 6/19 6 Assembly Kits for Switching Devices Assembly kit for 3VT moulded case circuit breakers ■ Overview 1 2 2 6 2 3 02157 1 Assembly kit for 3VT1, fixed, vertical 2 Assembly kit for 3VT2, fixed horizontal with mechanical lock 3 Assembly kit for 3VT3, draw out, vertical 6/20 Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for 3VT moulded case circuit breakers, for horizontal installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For the connection always use insulated busbars or cables. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanism. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). Hinges to be fitted to the individual covers are available as an option. ■ Selection and ordering data Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm Max. no. of circuit breakers Equipment mounting plate Cover 02143 No. of Connecpoles tion 02142 Circuit breaker 3VT moulded case circuit breakers, fixed and plug-in, for horizontal installation 3VT1 (160A) 3VT2 (250A) 3VT2 (250A) 3VT3 (630A) 3VT3 (630A) 3/4 3 4 3 4 front, rear front, rear front, rear front, rear front, rear Direct Direct, motorised Direct, motorised Direct, motorised Direct, motorised 150 150 200 200 250 600 600 600 600 600 400 400 400 400 400 1 1 1 1 1 8PQ6000-4BA21 8PQ6000-4BA23 8PQ6000-4BA24 8PQ6000-4BA27 8PQ6000-4BA26 8PQ2015-6BA17 8PQ2015-6BA18 8PQ2020-6BA22 8PQ2020-6BA23 8PQ2025-6BA14 6 ■ Selection and ordering data Ad hoc cover for type of op. mech. Height of Width module mm mm mm Max. no. of circuit breakers Equipment mounting plate 1 1 8PQ6000-4BA22 8PQ6000-4BA25 Cover 02145 No. of Connecpoles tion 02144 Circuit breaker Depth1 3VT moulded case circuit breakers, draw out, for horizontal installation 3VT2 (250A) 3VT3 (630A) 3/4 3/4 front, rear front, rear Direct, motorised Direct, motorised 250 300 600 600 ■ Description 400 400 8PQ2025-6BA13 8PQ2030-6BA20 ■ Configuration The mechnical interlock assembly kit contains a device holder with holes to fit the locking elements, the supporting rails and the fasteners. For the mechanical coupling of 2 circuit breakers installed in the horizontal position use the mechanical interlocking assembly and the relative accessories. ■ Selection and ordering data Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm Equipment mounting plate Cover 02147 No. of Connecpoles tion 02146 Circuit breaker Mechanical lock for Sentron 3VT moulded case circuit breaker, for horizontal installation 3VT2, 3VT3 1 Minimum depth – – – 100 600 400 8PQ6000-4BA34 8PQ2010-6BA01 Siemens LV 56 · 2008 6/21 Assembly Kits for Switching Devices Assembly kit for 3VT moulded case circuit breakers, for vertical installation ■ Description ■ Configuration The equipment support assembly kit contains a deep mounting plate for front and rear terminal bars and fastening crossbars. For installation on the front frame, choice of covers includes versions suitable for direct, motorised and rotary front operating mechanism. The covers are secured to the front frame by means of fast closing screws (1/4 of a turn). Hinges to be fitted to the individual covers are available as an option. For the connection always use insulated busbars or cables. a Front terminal bars and a breaking capacity ≤ 35 kA require two additional covers, 150mm each. Moreover, the phase separators and the terminal covers have to ordered. b Front terminal bars and a breaking capacity ≤ 65 kA require two additional covers, 200mm each. Moreover, the phase separators and the terminal covers have to ordered. ■ Selection and ordering data No. of Connection poles Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm Max. no. of circuit breakers DIN rail Cover 1-5 1-2 1-3 1-2 8PQ6000-3BA36 8PQ6000-3BA36 8PQ6000-3BA36 8PQ6000-3BA36 8PQ2045-6BA07 8PQ2045-6BA07 8PQ2045-6BA07 8PQ2045-6BA07 Max. no. of circuit breakers Equipment mounting plate Cover 1-3 1-2 1-2 1-2 8PQ6000-4BA28 8PQ6000-4BA30 8PQ6000-4BA31 8PQ6000-4BA32 8PQ2035-6BA18 8PQ2035-6BA20 8PQ2040-6BA18 8PQ2040-6BA20 Max. no. of circuit breakers Equipment mounting plate Cover 1-2 1-2 1-2 1 8PQ6000-4BA28 8PQ6000-4BA30 8PQ6000-4BA31 8PQ6000-4BA33 02149 02148 Circuit breaker Sentron 3VT moulded case circuit breakers, fixed, for vertical installation 3VT1 (160A) 3VT1 (160A) 3VT1 (160A) 3VT1 (160A) front front front front Direct Motorised Direct Motorised 450 450 450 450 Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm 600 600 600 600 400 400 400 400 No. of Connection poles 02150 Circuit breaker 02151 ■ Selection and ordering data 3VT moulded case circuit breakers, fixed and plug-in, for vertical installation 3VT2 (250A) 3VT2 (250A) 3VT3 (630A) 3VT3 (630A) a,b a,b a,b a,b 3 4 3 4 front, rear front, rear front, rear front, rear Direct, motorised Direct, motorised Direct, motorised Direct, motorised 350 350 400 400 Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm 600 600 600 600 400 400 400 400 Circuit breaker No. of Connection poles 02153 ■ Selection and ordering data 02152 6 3 3 4 4 3VT moulded case circuit breakers, draw out, for vertical installation 3VT2 (250A) 3VT2 (250A) 3VT3 (630A) 3VT3 (630A) 1 a,b a,b a,b a,b 3 4 3 4 front, rear front, rear front, rear front, rear Minimum depth 6/22 Siemens LV 56 · 2008 Direct, motorised Direct, motorised Direct, motorised Direct, motorised 350 350 400 400 600 600 600 600 400 400 400 400 8PQ2035-6BA18 8PQ2035-6BA20 8PQ2040-6BA18 8PQ2040-6BA21 Assembly Kits for Switching Devices Assembly kit for SENTRON 3K disconnectors ■ Overview 3 1 6 5 4 2 6 1 BS 88 fuse from IEC NH to British standard 2 IP20 fuse cover 3 IP20 single-pole cover, from 63 to 630 A 4 Standard products from the 3SB1 range are used as auxiliary contacts Choice of 5 8UC9 handle fox fixed installation in standard version (black) and emergency version (red) 6 8UC6 door locking handle witx ± 5 mm adaption tolerance in horizontal/vertical direction Standard version (black) and emergency version (red/yellow) All disconnector components up to the operating mechanism are provided with unique identificazion features Siemens LV 56 · 2008 6/23 Assembly Kits for Switching Devices Assembly kit for SENTRON 3K disconnectors ■ Technical specifications Standard IEC 60947-1, IEC 60947-3, VDE 0660 Teil 107 3KL50 3KL52 3KL53 3KL551) 3KL571) 3KL611) Rated continuous current Iu for fuses according to DIN 43620 A Size 63 00 u. 000 125 00 u. 000 160 00 u. 000 250 1 and 2 400 1 and 2 630 3 and 2 Cable lug, max (multiwire) conductor size mm2 35 70 120 150 2 × 150 or 1 × 240 2 × 240 Tightening torque Connecting screw Nm 6 ... 7,5 M6 7 ... 10 M6 18 ... 22 M8 35 ... 45 M10 35 ... 45 M10 56 M12 Type 1) Technical specifications for CSA approval upon request. Type 3KA71 1 Rated continuous current Iu A 32 45 63 80 100 125 Cable lug, max (multiwire) conductor size mm2 50 50 50 50 50 50 Busbar size mm2 16×3 16×3 16×3 16×3 16×3 16×3 Type 3KA71 2 Rated continuous current Iu A 160 200 250 Cable lug, max (multiwire) conductor size mm2 120 120 120 Busbar size mm2 20×5 20×5 20×5 Type 6 3KA71 3 Rated continuous current Iu A 315 400 Cable lug, max (multiwire) conductor size mm2 2×150 2×150 Busbar size mm2 2×25×5 2×25×5 Type 3KA71 4 Rated continuous current Iu A 630 Cable lug, max (multiwire) conductor size mm2 2×185 Busbar size mm2 2×32×6 Type 3KA71 5 Rated continuous current Iu A 800 1000 1250 1600 2000 2500 3150 Cable lug, max (multiwire) conductor size mm2 2×240 – – – – – – Busbar size mm2 2×50×5 2×50×6 2×50×8 3×50×8 3×50×12 4×50×12 8×50×12 Type 3KA71 6 Rated continuous current Iu A 1600 2000 2500 3150 Cable lug, max (multiwire) conductor size mm2 – – – – Busbar size mm2 2×80×10 2×80×10 3×80×10 2×100×10 Type 3KL71 1 Rated continuous current Iu A 32 45 63 80 Cable lug, max (multiwire) conductor size mm2 25 25 25 25 Busbar size mm2 12×3 12×3 12×3 12×3 Type 3KL71 2 Rated continuous current Iu A 100 125 160 Cable lug, max (multiwire) conductor size mm2 70 70 70 Busbar size mm2 16×4 16×4 16×4 Type 3KL71 3 Rated continuous current Iu A 200 250 Cable lug, max (multiwire) conductor size mm2 120 120 Busbar size mm2 25×4 25×4 Type 3KL71 4 Rated continuous current Iu A 315 400 Cable lug, max (multiwire) conductor size mm2 240 240 Busbar size mm2 32×5 32×5 Type 3KL71 5 Rated continuous current Iu A 630 800 Cable lug, max (multiwire) conductor size mm2 2×185 2×185 Busbar size mm2 2×40×6 2×40×6 6/24 Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for SENTRON 3K disconnectors ■ Description ■ Configuration The assembly kit for 3K disconnectors is made up of: • Mounting plate • Crossbars • Cover with holes to fit a door locking mechanism and fast closing screws • Fastening screws a Due to the size of its handle, the 1250A/50 kA 3KA715 disconnector requires an additional H = 200mm cover to be placed in the upper part (kit height + 200 mm). The depth adjustable mounting plate is mounted on crossbars and is suitable for front or rear terminal bars for the connection of cables or busbars. The respective terminal covers must be ordered too for the disconnector b Due to the size of its handle, the 3KA715 disconnector can be installed only in versions up to 1250A/35 kA. ■ Selection and ordering data Height of Width Depth1 module mm mm mm Max. no. of circuit breakers Equipment mounting plate Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism Door-coupling rotary operating mechanism 300 350 550 200 250 300 350 450 1 1 1 1 1 1 1 1 8PQ6000-2BA65 8PQ6000-2BA71 8PQ6000-2BA50 8PQ6000-2BA52 8PQ6000-2BA55 8PQ6000-2BA58 8PQ6000-2BA62 8PQ6000-2BA67 8PQ2030-6BA06 8PQ2035-6BA08 8PQ2055-6BA02 8PQ2020-6BA10 8PQ2025-6BA03 8PQ2030-6BA04 8PQ2035-6BA06 8PQ2045-6BA02 Ad hoc cover for type of op. mech. Height of Width Depth1 module mm mm mm Max. no. of circuit breakers Equipment mounting plate Cover 250 350 450 200 250 300 350 450 200 250 300 350 450 1 1 1 1 1 1 1 1 1 1 1 1 1 8PQ6000-2BA66 8PQ6000-2BA72 8PQ6000-2BA51 8PQ6000-2BA53 8PQ6000-2BA56 8PQ6000-2BA60 8PQ6000-2BA63 8PQ6000-2BA68 8PQ6000-2BA54 8PQ6000-2BA57 8PQ6000-2BA61 8PQ6000-2BA64 8PQ6000-2BA70 Ad hoc cover for type of op. mech. Cover 02072 No. of Connecpoles tion 02071 Circuit breaker Sentron 3K disconnector, horizontal installation 3KL50, 3KL52 3KL55, 3KL57 3KL61 3KL711, 3KA711 3KL712, 3KA712 3KL713, 3KA713 3KL714, 3KA714 3KL715, 3KA715 3/4 3/4 3/4 3/4 3/4 3/4 3/4 a 3/4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear 600 600 600 600 600 600 600 600 400 400 400 400 400 400 400 400 No. of Connecpoles tion 02073 Circuit breaker 02074 ■ Selection and ordering data Sentron 3K disconnector, vertical installation 3KL50, 3KL52 3KL55, 3KL57 3KL61 3KL711, 3KA711 3KL712, 3KA712 3KL713, 3KA713 3KL714, 3KA714 3KL715, 3KA715 3KL711, 3KA711 3KL712, 3KA712 3KL713, 3KA713 3KL714, 3KA714 3KL715, 3KA715 1 Minimum depth 3/4 3/4 3 3/4 3/4 3/4 3/4 b 3/4 3/4 3/4 3/4 3/4 3/4 front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear front, rear Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. Door locking mech. 600 600 600 600 600 600 600 600 800 800 800 800 800 400 400 400 400 400 400 400 400 400 400 400 400 400 8PQ2025-6BA05 8PQ2035-6BA10 8PQ2045-6BA01 8PQ2020-6BA11 8PQ2025-6BA04 8PQ2030-6BA05 8PQ2035-6BA07 8PQ2045-6BA03 8PQ2020-8BA04 8PQ2025-8BA02 8PQ2030-8BA02 8PQ2035-8BA04 8PQ2045-8BA01 Siemens LV 56 · 2008 6/25 6 Assembly Kits for Switching Devices Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ4 ■ Overview 02075 6 6/26 Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ4 ■ Technical Data Standards IEC 60947-1, IEC 60947-3, VDE 0660 Teil 107 Type 3NJ41 0 3NJ5 0 3NJ41 2 3NJ41 3 3NJ41 4 Conventional thermal current in free air Ith 1) in enclosed place Ithe 2) A A 160 160 250 225 400 360 630 567 Rated insulation voltage Ui V 750 1000 1000 1000 Rated operating voltage Ue AC 40 Hz ... 60 Hz V 690 690 690 690 kA (actual value) A kA (peak value) size/A 50 50 50 50 160 15 250 28 400 39 630 52 00/160 1/250 1 und 2/250 und 400 2 und 3/400 und 630 IP30 IP30 IP30 IP30 Rated conditional short-circuit current with fuses from AC 40 Hz to 60 Hz 690 V max. rated current of fuses In admissible fuse cut-off current For fuse kit according to standard IEC 60269-2-1 or sectioning brackets Degree of protection with open handle insert with side cover and clamps with closed handle insert IP10 IP10 IP10 IP10 Power dissipated from main current lines Ith W 18 23 49 110 Main conductor connection Connecting screws Flat rails Terminal, max. size of (multiwire) conductor Tightening torque Bracket / V-clamp mm mm2 Nm mm2 M8 24 95 10 ... 15 1,5 ... 70 M10 42 240 30 ... 35 25 ... 300 M12 42 240 30 ... 35 25 ... 300 M12 42 2403) 30 ... 35 25 ... 300 Nm M8 16 ... 18 M12 35 ... 40 M12 35 ... 40 M12 35 ... 40 Fastening screws for installation on busbars tightening torque required 6 1) When using different devices, take into account the load factor specified in standard EN 60439 part 1/DIN VDE 0660 part 500, Table 1 2) The minimum space needed for the casing is 0,185 m3. 3) A special kit supplied on request is necessary for the 2 x 240 mm2 connection. Rated currents for the horizontal distribution rails No. of bars Dimensions Rated current at 35° C ambient temperature [mm] IP ≤ IP41 IP 55 1 60 x 10 1560 1280 1 80 x 10 1740 1430 1 100 x 10 2180 1790 The data refer to normal operating conditions for indoor models as specified in standard IEC 60439-1, in particular with reference to an ambient temperature of 35 °C (24 h average). In different operating conditions, take into account the correction factors given in the chapter on “Planning and configuration”. Siemens LV 56 · 2008 6/27 Assembly Kits for Switching Devices Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ4 ■ Description ■ Configuration The device holder is made up of crossbars and depth adjustable corner supports for the horizontal installation of distribution busbars. The panels are secured to the frame by means of a snap-in system. The device holder is suitable for use behind a closed door. Kit for the connection of cables from the bottom and from the top. Copper busbars are not included in the kit. Two supports for the distribution busbars must be ordered. ■ Selection and ordering data Width Switches mm for kit Device holder 800 800 600 800 8PQ6000-2BA48 8PQ6000-2BA48 Support for distribution busbars Direct activation panel 02078 Height mm 02077 Num- Installation ber of technique poles 02076 Switch Sentron 3NJ4 disconnector with fuses 3NJ4, BG 1, 2, 3 3NJ4, BG 1, 2, 3 3 3 fixed fixed 4 6 3NJ5974-0AB 3NJ5974-0AB 02079 02080 6 Configuration for cable entry from the bottom 6/28 Siemens LV 56 · 2008 Configuration for cable entry from the top 8PQ2000-6BA06 8PQ2000-8BA06 Assembly Kits for Switching Devices Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ6 ■ Overview 1 2 3 6 1 Fixed cover for busbars 2 3NJ6 in-line fuse disconnectors 3N76 4 3 Cable connection compartment door 4 Fixed cover for PE busbars Siemens LV 56 · 2008 6/29 Assembly Kits for Switching Devices Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ6 ■ Technical Data Standards IEC 60947-1 Type Breaking capacity 3NJ60 0.-1 S 3NJ60 1.-1 S 3NJ60 1.-3 H 3NJ60 2.-1 S 3NJ60 2.-3 H 3NJ60 3.-1 S 3NJ60 3.-3 H Rated uninterrupted current Iu1) for kit wtih fuses according to standard IEC 60269 A 160 Rated operating current Ue • with a rated current of AC V Hz 690 50/60 Rated insulation voltage Ui V 1000 Rated impulse current Uimp V 8000 Rated conditional short circuit current • Short-circuit resistance (actual value) • Short-circuit switching capacity (actual value) kA kA 100 55 66 55 66 55 66 55 66 A A A A 160 – 160 – 160 160 160 125 250 – 200 – 250 250 200 200 400 – 400 – 400 400 400 315 630 – 630 – 630 630 630 500 A A A A 480 – 480 – 480 1280 480 1000 750 – 600 – 750 2000 600 1600 1200 – 1200 – 1200 3200 1200 2520 1890 – 1890 – 1890 5040 1890 4000 Rated operating current Ie • with AC 500 V AC-22B AC-23B • with AC 690 V AC-22B AC23B Short-circuit breaking power • with AC 500 V cosϕ = 0,65 cosϕ = 0,35 • with AC 690 V cosϕ = 0,95 cosϕ = 0,35 Operating life • overall • mechanical 6 3NJ60 0.-3 H • electrical (690 V, cosϕ = 0,65) Power dissipated (including NH fuses with lower dissipation power according to VDE 0636 part 2) 400 630 operat- 1600 ing cycles operat- 1400 ing cycles operat- 200 ing cycles 1600 1000 1000 1400 800 800 200 200 200 W 73 114 215 39 Permissible operating position horizontal Degree of protection (in operating conditions) IP41 Main conductor connection • Terminal connection – Conductor size Al/Cu, single or multiwire according to DIN 46235 (Cu) and DIN 46239 (Al) – screw dimensions – tightening torque • Clamp connection – conductor size (Al/Cu), rn – conductor size (Al/Cu), re – conductor size (Al/Cu), sm – conductor size (Al/Cu), se – tightening torque required 250 mm2 1 x 10 ... 95 1 x 95 ... 240 1 x 300, 2 x 95 ... 240 1 x 300, 2 x 95 ... 240 Nm M8 15 M12 30 2 x M12 30 2 x M12 30 mm2 mm2 mm2 mm2 Nm 1 x 10 ... 50 1 x 10 ... 50 1 x 35 ... 95 1 x 50 ... 95 10 1 x 16 ... 35 1 x 16 ... 70 1 x 35 ... 240 1 x 35 ... 300 25 2 x 16 ... 35 2 x 16 ... 70 2 x 35 ... 240 2 x 35 ... 300 25 2 x 16 ... 35 2 x 16 ... 70 2 x 35 ... 240 2 x 35 ... 300 25 1) Standard IEC 60439 requires that rated uninterrupted current be reduced if busbars are installed in the control board. Rated currents for the vertical distribution busbar system No. of bars Dimensions Rated current at 35° C ambient temperature [mm] IP ≤ IP41 1 60 x 10 1560 1 80 x 10 2100 The data refer to normal operating conditions for indoor models as specified in standard IEC 60439-1, in particular with reference to an ambient temperature of 35 °C (24 h average). In different operating conditions, take into account the correction factors given in the chapter on “Planning and configuration”. 6/30 Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for in-line fuse switch disconnectors SENTRON 3NJ6 ■ Description ■ Configuration The assembly kit for Sentron 3NJ6 in-line fuse disconnectors in horizontal configuration contains vertical bars and busbar supports suitable for 3- and 4-pole versions. Depending on the interior organisation of the rack, configure the rack, interior bearing structures with a usable height of 1600 mm, exterior bearing structures and partitions. The device compartment consists of a modular door, vertical and horizontal partitions, a device holder. The assembly kit can be used with racks 1000mm or 1200mm width and 400mm, 600mm or 800mm deep, and it occupies a width of 600 mm. For each assembly kit for Sentron 3NJ6 in-line fuse disconnectors, configure 8 protective covers 3NJ6916-4EA00. The 400mm and 600mm wide cable connecting compartment can be equipped with standard components for N and PE busbars, and cable supporting brackets. Depending on field conditions, it is necessary to configure a fixed cover before the busbars, a fixed cover before the PE busbars and a door (for the cable connecting compartment). Max degree of protection IP41 Copper busbars are not included in the kit. ■ Selection and ordering data Number of poles Installation technique Height mm Width mm Ordering code UI 8PQ3000-1BA48 1 Assembly kit for Sentron 3NJ6 in-line fuse disconnectors, plug-in installation, horizontal configuration 3/4 steck 1600 600 02082 6 Compartment with modular door for on site installation of Sentron 3NJ6 in-line fuse disconnectors 600 600 8PQ3000-1BA50 8PQ3000-1BA51 1 1 3NJ6916-4EA00 1 02083 200 400 02084 Protective covers for Sentron 3NJ6 in-line fuse disconnectors Siemens LV 56 · 2008 6/31 Assembly Kits for Switching Devices Assembly kits for modular installations devices ■ Overview 02090 6 6/32 Siemens LV 56 · 2008 Assembly Kits for Switching Devices Assembly kit for modular installation devices ■ Description ■ Configuration The kit for modular devices mounted on DIN rails is made up of: • Support brackets • Variable depth 35mm DIN rail in ALU • Cover with cut-out DIN and fast closing screws (1/4 turn) • Fastening screws The multiple DIN rail makes it possible to snap the Sikclip wiring system onto the rear side. The DIN rail can be modifies and adjusted for depth as desired. The horizontal raceway fastening kit contains the support and the necessary fasteners. The DIN rail can be adjusted for a distance from the front cover of 47.5mm, 56.5mm and 75.5mm. The support bracket makes it possible to fit a vertical raceway up to 60mm in width. For each row, order 1 DIN rail kit of matching width. ■ Selection and ordering data Height of module mm Width mm Modular units DIN rail Cover 02092 02091 Row centre distance mm DIN rail assembly kit for modular devices, 1 row 150 150 600 24 8PQ6000-3BA36 8PQ2015-6BA07 200 200 600 24 8PQ6000-3BA36 8PQ2020-6BA12 150 150 800 36 8PQ6000-3BA37 8PQ2015-8BA03 200 200 800 36 8PQ6000-3BA37 8PQ2020-8BA05 Width mm Modular units DIN rail Cover ■ Selection and ordering data Height of module mm 6 02093 02091 Row centre distance mm DIN rail assembly kit for modular devices, 2 row 150 300 600 48 2 x 8PQ6000-3BA36 8PQ2030-6BA07 200 400 600 48 2 x 8PQ6000-3BA36 8PQ2040-6BA10 150 300 800 72 2 x 8PQ6000-3BA37 8PQ2030-8BA03 200 400 800 72 2 x 8PQ6000-3BA37 8PQ2040-8BA10 Width mm Modular units DIN rail Cover ■ Selection and ordering data Height of module mm 02094 02091 Row centre distance mm DIN rail assembly kit for modular devices, 3 row 150 450 600 72 3 x 8PQ6000-3BA36 8PQ2045-6BA04 200 600 600 72 3 x 8PQ6000-3BA36 8PQ2060-6BA04 150 450 800 108 3 x 8PQ6000-3BA37 8PQ2045-8BA02 200 600 800 108 3 x 8PQ6000-3BA37 8PQ2060-8BA02 Row centre distance Height of module mm Width mm Modular units – – – Ordering code UI 8PQ6000-0BA16 2 Horizontal raceway fastening brackets 600/800 01660 – Siemens LV 56 · 2008 6/33 Assembly Kits for Switching Devices Assembly kit for modular installation devices ■ Description – fixing with clips onto the back of the DIN rail (top hat rail). Sikclip is a quick wiring system simplifying the connection of flush-mounted circuit breakers. Distribution terminal blocks with IMQ label, in 2-pole or 4-pole versions, for currents up to 125 A. Icw up to 4.3 kA and Ipk up to 22 kA. For direct fastening onto the DIN rails. – for direct mounting on the rear vertical CU busbar ■ Technical specifications Max. rated operating current In 250 A at 40 °C ambient temperature Max. rated output current In 63 A at 40 °C ambient temperature Rated operating voltage Un AC 400 V Rated insulation voltage AC 660 V Test voltage 2,5 kV, 50 Hz Degree of protection IP20 Connecting conductors 40 A (6 mm2), 63 A (10 mm2) Type of connecting conductor H07VK Colour RAL 7035 Operating temperature –5 °C to +60 °C Applicable standards EN 60947-1, EN 60439-3 ■ Selection and ordering data Model Length Colour Ordering code Sikclip wiring system 6 12 TE 5ST2 520 24 TE 5ST2 521 36 TE 5ST2 522 Connecting conductors 6 mm2 120 mm 10 mm2 120 mm 6 mm2 220 mm 10 mm2 220 mm black 5ST2 523 blue 5ST2 524 black 5ST2 525 blue 5ST2 526 black 5ST2 527 blue 5ST2 528 black 5ST2 530 blue 5ST2 531 Push-in connector Brackets 5ST2 532 for anchoring to back of DIN rail (pair) Model TE Distribution terminal blocks 100 A 7 openings per pole 5 × 1,5 up to 6 mm2 + 2 × 6 up to 16 mm2 125 A 6/34 Siemens LV 56 · 2008 5ST2 533 Icw (1 s) Ipk kA kA Ordering code 2 poles 4 3,1 20 8GF9 871 4 poles 5 3,1 20 8GF9 872 11 openings per pole 2 poles 7 4,3 22 8GF9 873 7 × 1,5 up to 6 mm2 + 2 × 6 up to 16 mm2 + 2 × 16 up to 35 mm2 4 poles 7 4,2 22 8GF9 874 15 openings per pole 2 poles 8 4,2 22 8GF9 875 11 × 1,5 up to 6 mm2 + 2 × 6 up to 16 mm2 + 2 × 16 up to 35 mm2 4 poles 8 4,3 22 8GF9 876 7 Covers, Modular Doors, Mounting Plate, 19” Rack 7/2 Covers 7/4 Modular doors 7/7 Modular mounting plates 7/8 Mounting plate for electrotechnical applications 7/9 19” rack Siemens LV 56 · 2008 Covers, Modular Doors, Mounting Plate, 19” Rack Covers ■ Description ■ Configuration The kit consists a cover and guick-release locks. The covers are secured to the board frame by means of captive fast closing screws (1/4 of a turn). If the fast closing screws are replaced with hinges, the holes must be closed with plugs. Use a pair of hinges per cover. 1/4 turn screws are tightened and loosened by means of a flathead screwdriver. In addition to fastening the cover, the screw also performs a grounding function for the cover. Using the hinge options, the cover can be hinged on the right or the left as desired. The hinges are mounted without having to use any additional mechanical parts and also perform a grounding function for the cover. ■ Selection and ordering data Cut-out Height of module mm Width mm Ordering code UI – 50 600 8PQ2005-6BA01 1 – 100 600 8PQ2010-6BA01 1 – 150 600 8PQ2015-6BA02 1 – 200 600 8PQ2020-6BA01 1 – 250 600 8PQ2025-6BA01 1 – 300 600 8PQ2030-6BA01 1 – 350 600 8PQ2035-6BA01 1 – 400 600 8PQ2040-6BA01 1 – 500 600 8PQ2050-6BA01 1 – 550 600 8PQ2055-6BA01 1 – 600 600 8PQ2060-6BA01 1 – 650 600 8PQ2065-6BA01 1 – 800 600 8PQ2080-6BA01 1 – 50 800 8PQ2005-8BA01 1 – 100 800 8PQ2010-8BA01 1 – 150 800 8PQ2015-8BA02 1 – 200 800 8PQ2020-8BA01 1 – 250 800 8PQ2025-8BA01 1 – 300 800 8PQ2030-8BA01 1 – 350 800 8PQ2035-8BA01 1 – 400 800 8PQ2040-8BA01 1 – 500 800 8PQ2050-8BA01 1 – 550 800 8PQ2055-8BA01 1 – 600 800 8PQ2060-8BA01 1 – 650 800 8PQ2065-8BA01 1 – 800 800 8PQ2080-8BA01 1 2 instruments 72 x 72 mm + 2 change-over switches 200 600 8PQ2020-6BA03 1 4 instruments 72 x 72 mm + 1 change-over switch 200 600 8PQ2020-6BA02 1 2 instruments 72 x 72 mm + 2 change-over switches 200 800 8PQ2020-8BA03 1 4 instruments 72 x 72 mm + 1 change-over switch 800 8PQ2020-8BA02 1 Covers with cut-outs 01693 7 01661 Covers without cut-outs 7/2 Siemens LV 56 · 2008 200 Covers, Modular Doors, Mounting Plate, 19” Rack Covers ■ Description ■ Configuration The kit consists a cover and guick-release locks. The covers are secured to the board frame by means of captive fast closing screws (1/4 of a turn). If the fast closing screws are replaced with hinges, the holes must be closed with plugs. Use a pair of hinges per cover. 1/4 turn screws are tightened and loosened by means of a slot or cross-slot screwdriver. In addition to fastening the cover, the screw also performs a grounding function for the cover. Using the hinge options, the cover can be hinged on the right or the left as desired. The hinges are mounted without having to use any additional mechanical parts and also perform a grounding function for the cover. ■ Selection and ordering data Height of module mm Width mm Ordering code 2 instruments 96 x 96 mm + 2 change-over switches 400 600 8PQ2040-6BA04 1 4 instruments 96 x 96 mm + 1 change-over switch 400 600 8PQ2040-6BA03 1 2 instruments 96 x 96 mm + 2 change-over switches 400 800 8PQ2040-8BA04 1 4 instruments 96 x 96 mm + 1 change-over switch 400 800 8PQ2040-8BA03 1 Cut-out UI 01810 01809 Covers 400mm with cut-outs 7 Covers with ventilation fins 100 600 8PQ2010-6BA02 1 ventilated 100 800 8PQ2010-8BA02 1 – – – 8PQ2000-0BA01 10 – – 8PQ2000-0BA02 10 01811 ventilated 01697 Cover hinges kit Closing plugs for cover holes 01812 – Siemens LV 56 · 2008 7/3 Covers, Modular Doors, Mounting Plate, 19” Rack Modular doors ■ Overview 1 2 3 3 2 7 2 1 Exterior front cover for main busbars 2 Modular door 3 Cover for degree of protection IP55 02095 4 Exterior front cover for PE bar 4 7/4 Siemens LV 56 · 2008 Covers, Modular Doors, Mounting Plate, 19” Rack Modular doors ■ Description ■ Configuration The “exterior front covers” kit for the main busbars and the PE bar contains the cover and an anchoring support. Each cubicle with modular doors must be fitted with a front cover before the busbars and the PE bar. Height of module mm 02097 02096 ■ Selection and ordering data Width mm Ordering code IP55 upgrade Exterior front cover for main busbars 8PQ2022-6BA01 8PQ2022-6BA02 8PQ2022-8BA01 8PQ2022-8BA02 Height of module mm Width mm Ordering code IP55 upgrade 02098 600 800 02158 225 225 Exterior front cover for PE bars 175 600 8PQ2000-6BA07 8PQ2015-6BA13 175 800 8PQ2000-8BA07 8PQ2015-8BA08 7 Siemens LV 56 · 2008 7/5 Covers, Modular Doors, Mounting Plate, 19” Rack Modular doors ■ Description ■ Configuration The modular doors kit contains a door with degree of protection IP4X, door hinge support, hinges, green column identification strip and two-way interlocking mechanism. The “front covers” kit contains the cover and an anchoring support. A combination of front frame and covers with modular doors in a cubicle is not possible. When using the equipment with modular doors, the remaining heights must be closed with 50mm or 100mm height front covers. Height of module mm 02053 02159 ■ Selection and ordering data Width mm Ordering code IP55 upgrade Modular doors 8PQ2015-6BA10 8PQ2015-6BA12 8PQ2020-6BA14 8PQ2020-6BA15 250 600 8PQ2025-6BA07 8PQ2025-6BA08 300 600 8PQ2030-6BA10 8PQ2030-6BA12 350 600 8PQ2035-6BA12 8PQ2035-6BA13 400 600 8PQ2040-6BA12 8PQ2040-6BA13 450 600 8PQ2045-6BA05 8PQ2045-6BA06 500 600 8PQ2050-6BA03 8PQ2050-6BA04 550 600 8PQ2055-6BA04 8PQ2055-6BA06 600 600 8PQ2060-6BA06 8PQ2060-6BA07 650 600 8PQ2065-6BA03 8PQ2065-6BA04 700 600 8PQ2070-6BA03 8PQ2070-6BA04 750 600 8PQ2075-6BA01 8PQ2075-6BA02 800 600 8PQ2080-6BA03 8PQ2080-6BA04 150 800 8PQ2015-8BA05 8PQ2015-8BA07 200 800 8PQ2020-8BA07 8PQ2020-8BA08 250 800 8PQ2025-8BA04 8PQ2025-8BA05 300 800 8PQ2030-8BA05 8PQ2030-8BA06 350 800 8PQ2035-8BA06 8PQ2035-8BA07 400 800 8PQ2040-8BA12 8PQ2040-8BA13 450 800 8PQ2045-8BA03 8PQ2045-8BA04 500 800 8PQ2050-8BA03 8PQ2050-8BA04 550 800 8PQ2055-8BA03 8PQ2055-8BA06 600 800 8PQ2060-8BA04 8PQ2060-8BA05 650 800 8PQ2065-8BA03 8PQ2065-8BA04 700 800 8PQ2070-8BA01 8PQ2070-8BA02 750 800 8PQ2075-8BA01 8PQ2075-8BA02 800 800 8PQ2080-8BA03 8PQ2080-8BA04 Height of module mm Width mm Ordering code IP55 upgrade 02100 600 600 02099 7 150 200 Front covers 7/6 50 600 8PQ2005-6BA04 8PQ2005-6BA03 100 600 8PQ2010-6BA04 8PQ2010-6BA03 50 800 8PQ2005-8BA04 8PQ2005-8BA03 100 800 8PQ2010-8BA04 8PQ2010-8BA03 Siemens LV 56 · 2008 Covers, Modular Doors, Mounting Plate, 19” Rack Modular mounting plates ■ Description ■ Configuration The modular mounting plate kit is made up of: • Mounting plate • Crossbars • Cover and fast closing screws • Fastening screws In mounting plates with holes, hole spacing is 25 x 25 mm. Hole diameter is 5.4 mm and the holes are suitable for M6 selftapping screws. The mounting plate can be ordered with or without holes and can be adjusted for depth. ■ Selection and ordering data Height of module mm Width mm Ordering code UI 02101 Mounting plate kit without holes 200 600 8PQ3000-1BA56 1 400 600 8PQ3000-1BA61 1 600 600 8PQ3000-1BA65 1 800 600 8PQ3000-1BA26 1 200 800 8PQ3000-1BA58 1 400 800 8PQ3000-1BA63 1 600 800 8PQ3000-1BA67 1 800 800 8PQ3000-1BA28 1 200 600 8PQ3000-1BA57 1 400 600 8PQ3000-1BA62 1 600 600 8PQ3000-1BA66 1 800 600 8PQ3000-1BA27 1 200 800 8PQ3000-1BA60 1 400 800 8PQ3000-1BA64 1 600 800 8PQ3000-1BA68 1 800 800 8PQ3000-1BA30 1 02102 Mounting plate kit with holes Siemens LV 56 · 2008 7/7 7 Covers, Modular Doors, Mounting Plate, 19” Rack Mounting plate for electrotechnical applications ■ Description ■ Configuration The “mounting plate” kit for electrotechnical applications contains the mounting plate and the brackets to fasten it to the cubicle. By means of 6 additional crossbars the mounting plate can be adjusted for depth. The crossbars are described in the chapter on “Accessories”. The brackets are fastened to the side upright or to the rear part of the cubicle. To facilitate the installation of the mounting plate, the lower fastening brackets are designed for slanted plate insertion when the plate has been made ready and wired on the work bench. The connecting panel kit makes it possible to create an uninterrupted surface when two or more adjacent boards have to be mechanically connected. ■ Selection and ordering data Height of module mm Width mm Ordering code UI 1 01672 Mounting plate 1600 400 8PQ3000-0BA33 1600 600 8PQ3000-0BA35 1 1600 800 8PQ3000-0BA37 1 1600 1000 8PQ3000-1BA06 1 1600 1200 8PQ3000-1BA07 1 1900 400 8PQ3000-0BA32 1 1900 600 8PQ3000-0BA34 1 1900 800 8PQ3000-0BA36 1 1900 1000 8PQ3000-1BA04 1 1900 1200 8PQ3000-1BA05 1 1600 – 8PQ3000-1BA10 1 1900 – 8PQ3000-1BA08 1 Connecting panel 01700 7 7/8 Siemens LV 56 · 2008 Covers, Modular Doors, Mounting Plate, 19” Rack 19” rack ■ Description ■ Configuration For the installation of a 19” rack, a fixed version kit for 600mm wide cubicles and a swivel version kit for 800mm wide cubicles are available. 1 height unit (HE) = 44.45 mm. Swivel version kit for use with right or left hinges. The maximum weight of the rack is 160 kg. ■ Selection and ordering data Equipment height mm Height of electronic unit HE Cubicle width mm Version 1800 39 600 fixed 8PQ3000-1BA11 1 1800 39 800 swivel 8PQ3000-1BA12 1 Ordering code UI NSEX_00007 Kit per 19” rack 7 Siemens LV 56 · 2008 7/9 Covers, Modular Doors, Mounting Plate, 19” Rack Notes 7 7/10 Siemens LV 56 · 2008 8 Internal Separation 8/2 General Data 8/4 Main busbar system 8/7 Vertical distribution busbar system 8/9 Modular Separation for Switching Devices Siemens LV 56 · 2008 Internal Separation General Data ■ Overview A fundamental characteristic of switchgear is the presence of internal separation forms as required by the applicable standards. The main purpose of internal partitions is to make sure that all switching, control and maintenance operations can be performed in full safety, while ensuring uninterrupted system operation. Advantages − Reduction of possible hazards during connection, scheduled maintenance and extraordinary maintenance operations − Attenuation of consequences of local faults and faster resumption of regular operation Applications: − Protection against contact between live parts belonging to adjacent functional units. Degree of protection required: IP2X or IPXXB; − Protection against the intrusion of foreign bodies from a functional unit into an adjacent functional unit. Degree of protection required: IP 2X or higher; − Low risk of internal arc triggering. Functional unit (definition): part of a switchgear containing all the electrical and mechanical components that contribute to the fulfilment of the same function, e.g., infeed and outfeed circuit breakers, measuring unit, etc. 8 SIVACON S4 With SIVACON S4, internal separation form 2b is achieved by separating the main busbar systems and the distribution busbars by means of partitions and covers. Assembly kits for switching and protection devices which comply with internal separation form 1 in their basic version do not require any additional separation to achieve internal separation form 2b. If only 1 circuit breaker per cubicle is used, form 3b corresponds to form 4b (3b = 4b). 8/2 Siemens LV 56 · 2008 Definitions according to IEC 60439-1, CEI EN 60439-1 ■ Form 1 No internal separation ■ Form 2 Separation between busbars and functional units ■ Form 2a Separation between busbars and functional units, no separation between connections and busbars ■ Form 2b Separation between busbars and functional units, separation between connections and busbars ■ Form 3 • Separation between busbars and all functional units • Separation between all the functional units • Separation between the connections of conductors going to the exterior and the functional units, but no separation between the connections and the functional units ■ Form 3a No separation between connections and busbars ■ Form 3b Separation between connections and busbars ■ Form 4 • Separation between busbars and all functional units • Separation between all the functional units • Separation between the connections of conductors going to the exterior which are associated with functional units and the connections of all the other functional units and the busbars ■ Form 4a Connections in the same cell as the functional unit concerned ■ Form 4b Connections not in the same cell as the functional unit concerned Special separation forms or higher degrees of protection must be agreed upon by the manufacturer and the user. Internal Separation General Data Form 1 Functional unit Input and output connections 1 Main busbars 2 Distribution busbars 3 4 Input circuit Output circuit 01734 ° Form 3a 01736 Form 2b 01735 Form 2a Form 3b 01740 Form 4b 01739 Form 4a 01738 01737 8 Siemens LV 56 · 2008 8/3 Internal Separation Main busbar system 02104 02103 02106 ■ Overview Main busbar system in standard position, top front depth 400mm Main busbar system in standard position, top front depth 600mm Main busbar system in standard position, top front - rear depth 800mm Main busbar system in standard position, top front and rear depth 800mm 8/4 Siemens LV 56 · 2008 02107 02105 8 Main busbar system in standard position in optional adjustable position, rear depth 800mm Internal Separation Main busbar system ■ Description ■ Configuration The form 2b separation kit for horizontal main busbar systems contains the metal parts and the fastening screws need to achieve this separation form. One piece per cubicle corresponding to the relative dimensions for equipment compartment or cable compartment. To use a section as a riser duct it is necessary to use a side upright matching the equipment height and depth, with no bottom plate partition. ■ Selection and ordering data Position of main busbars Width mm Cubicle depth mm Height of module mm Ordering code UI 1 01726 Busbar system in standard position, form 2b separation front top 200 600 225 8PQ3000-1BA53 front top 400 600 225 8PQ3000-0BA52 1 front top 600 600 225 8PQ3000-0BA53 1 front top 800 600 225 8PQ3000-0BA54 1 front top 1000 600 225 8PQ3000-1BA14 1 front top 1200 600 225 8PQ3000-1BA16 1 front or rear top 200 800 225 8PQ3000-1BA54 1 front or rear top 400 800 225 8PQ3000-0BA55 1 front or rear top 600 800 225 8PQ3000-0BA56 1 front or rear top 800 800 225 8PQ3000-0BA57 1 front or rear top 1000 800 225 8PQ3000-1BA17 1 front or rear top 1200 800 225 8PQ3000-1BA18 1 front or rear top 200 800 225 8PQ3000-1BA55 1 front or rear top 400 800 225 8PQ3000-0BA58 1 front or rear top 600 800 225 8PQ3000-0BA60 1 front or rear top 800 800 225 8PQ3000-0BA61 1 front or rear top 1000 800 225 8PQ3000-1BA20 1 front or rear top 1200 800 225 8PQ3000-1BA21 1 front top 200 400 225 8PQ3000-1BA52 1 front top 400 400 225 8PQ3000-0BA67 1 front top 600 400 225 8PQ3000-0BA68 1 front top 800 400 225 8PQ3000-0BA70 1 front top 1000 400 225 8PQ3000-1BA13 1 front top 1200 400 225 8PQ3000-1BA15 1 rear variable 400 400*, 600*, 800 250 8PQ3000-0BA78 1 rear variable 600 400*, 600*, 800 250 8PQ3000-0BA80 1 rear variable 800 400*, 600*, 800 250 8PQ3000-0BA81 1 rear variable 1000 400*, 600*, 800 250 8PQ3000-1BA22 1 rear variable 1200 400*, 600*, 800 250 8PQ3000-1BA23 1 01728 01727 Busbar system in free position, form 2b separation * with modular door. Siemens LV 56 · 2008 8/5 8 Internal Separation General Data ■ Overview 1 1 2 2 01725 8 2 1 Form 2b separation for horizontal main busbar system 2 Form 2b separation for vertical distribution busbars 8/6 Siemens LV 56 · 2008 Internal Separation Vertical distribution busbar system ■ Description ■ Configuration The form 2b vertical distribution busbar separation kit contains the parts and the fasteners needed to achieve this separation form. For cubicles placed side-by-side, order an additional separation kit to obtain form 2b for the vertical busbars or separation between cubicles. The protective front separation for the busbar compartment cannot be fitted to the back of 400 mm deep cubicles. ■ Selection and ordering data Position of main busbars Width mm Cubicle depth mm Ordering code UI Vertical distribution busbar system with main busbars at the top, form 2b separation 200, 400 400 8PQ4000-0BA05 1 front 200, 400 600 8PQ4000-0BA07 1 front and rear 200, 400 800 8PQ4000-0BA64 1 front and rear 200 800 8PQ4000-0BA02 1 front and rear 400 800 8PQ4000-0BA01 1 01741 01723 01722 front 01729 8 Vertical distribution busbar system without main busbars, form 2b separation 200, 400 400 8PQ4000-0BA06 200, 400 600 8PQ4000-0BA03 1 1 front and rear 200, 400 800 8PQ4000-0BA76 1 01741 front and rear front and rear Additional front cover for vertical busbar compartment 200 – 8PQ3000-0BA50 1 400 – 8PQ3000-0BA51 1 01665 – – Siemens LV 56 · 2008 8/7 Internal Separation Vertical distribution busbar system ■ Description ■ Configuration The separation between cubicles kit is symmetrically split and is provided with removable pre-sectioning units for use in conjunction with horizontal busbar systems. For 800 mm deep cubicles, order two 400 mm deep separation kits. ■ Selection and ordering data Cubicle depth mm Height Ordering code UI 400 cubicle height 8PQ3000-0BA15 1 600 cubicle height 8PQ3000-0BA16 1 01641 Vertical separation between cubicles 8 8/8 Siemens LV 56 · 2008 Internal Separation Modular Separation for Switching Devices ■ Description ■ Configuration The crossbars and separation supporting rails kit makes it possible to fasten the rear of the kit supporting crossbars without having to use screws. Order 1 crossbars and separation supporting rails kit for cubicles sized 600 mm or 800 mm. Required to achieve separation forms 3 and 4. It is also used to fasten the horizontal and vertical partitions in the rear part of the cubicle in form ≥ 2b without having to use screws. ■ Selection and ordering data Equipment height mm Ordering code UI 1600 8PQ3000-0BA82 2 1800 8PQ3000-0BA83 2 02109 01744 Crossbars and separation supporting rails kit, for forms 3 and 4 separation 02108 8 Siemens LV 56 · 2008 8/9 Internal Separation Modular Separation for Switching Devices ■ Description ■ Design The form 3 separation kit for Sentron 3WL circuit breakers ensures rear and side separation. The form 3 separation kit for Sentron 3WL circuit breakers can be installed only in 600mm and 800mm deep cubicles. This separation cannot be used for circuit breaker 3WL 1240. ■ Selection and ordering data Size No. of poles Width mm Height of module mm Ordering code UI Sentron 3WL, fixed version, form 3 separation 3/4 600 550 8PQ5000-0BA08 1 Gr II 3 600 550 8PQ5000-0BA13 1 Gr I 3/4 800 550 8PQ5000-1BA65 1 Gr II 3/4 800 550 8PQ5000-0BA11 1 01648 Gr I Sentron 3WL, draw out version, form 3 separation 3/4 600 550 8PQ5000-0BA07 1 Gr II 3 600 550 8PQ5000-0BA12 1 Gr I 3/4 800 550 8PQ5000-1BA66 1 Gr II 3/4 800 550 8PQ5000-0BA10 1 Size Current No. of poles Ordering code UI 01648 Gr I ■ Selection and ordering data Version Width mm Height of module above the circuit breaker mm under the circuit breaker mm Sentron 3WL, connection to the cables, form 4 separation 1600 3/4 Fixed/Draw out 600 200 250 8PQ5000-0BA30 1 Gr I 1600 3/4 Fixed/Draw out 800 200 250 8PQ5000-1BA68 1 Gr II 3200 3/4 Fixed/Draw out 800 350 400 8PQ5000-0BA38 1 1 01650 Gr I 8 Sentron 3WL, connection to the vertical distribution busbars, form 4 separation 1600 3/4 Fixed/Draw out 600 250 300 8PQ5000-0BA14 Gr I 1600 3/4 Fixed/Draw out 800 250 300 8PQ5000-1BA67 1 Gr II 3200 3/4 Fixed/Draw out 800 300 350 8PQ5000-0BA21 1 02110 01649 Gr I Cubicle with built-in busbars and form 3 and 4b separation 8/10 Siemens LV 56 · 2008 Internal Separation Modular Separation for Switching Devices ■ Overview 01638 2 1 Separation for 400mm deep cubicles 3 2 3 3 01816 1 Horizontal partition 1 2 Vertical separation on connecting cable side 3 Rear vertical separation 8 Separation for 600mm and 800mm deep cubicles Siemens LV 56 · 2008 8/11 Internal Separation Modular Separation for Switching Devices ■ Description ■ Configuration For assembly kits such as Sentron 3VL, 3VT, 3K, modular devices on DIN rail and modular mounting plates, a modular separation system is available. For modular devices on DIN rail supporting crossbars must also be provided. Equipment assembly kits achieve form 1 separation. 400mm deep cubicles require a horizontal partition and a vertical partition for each branch unit. Form 2b is achieved through the separation of main bars and vertical distribution busbars. 600mm and 800mm deep cubicles require a horizontal partition and a vertical partition for each branch unit. Form 4b is achieved through the combination of horizontal, vertical and rear partitions. For 50mm high vertical partitions, order 2 25mm kits. Height of module mm Width mm Cubicle depth mm Branch current A Ordering code UI 25 – 400, 600, 800 – 8PQ5000-2BA63 2 – – 600 800 400, 600, 800 400, 600, 800 – – 8PQ5000-2BA61 8PQ5000-2BA62 1 1 25 100 150 200 200 250 250 300 300 300 350 350 400 450 500 550 600 600 650 700 700 800 – – – – – – – – – – – – – – – – – – – – – – 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 400, 600, 800 – – – ≤ 250 ≥ 400 ≤ 250 ≥ 400 ≤ 250 ≥ 400 ≥ 800 – ≥ 800 – – – – – ≥ 800 – – ≥ 800 – 8PQ5000-2BA63 8PQ5000-2BA27 8PQ5000-2BA28 8PQ5000-2BA30 8PQ5000-2BA31 8PQ5000-2BA32 8PQ5000-2BA33 8PQ5000-2BA34 8PQ5000-2BA35 8PQ5000-2BA46 8PQ5000-2BA36 8PQ5000-2BA47 8PQ5000-2BA37 8PQ5000-2BA38 8PQ5000-2BA40 8PQ5000-2BA41 8PQ5000-2BA42 8PQ5000-2BA48 8PQ5000-2BA43 8PQ5000-2BA44 8PQ5000-2BA50 8PQ5000-2BA45 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 02111 Fastening crossbars 02112 Horizontal partition Vertical separation on connecting cable side 02113 8 02114 Rear vertical separation 8/12 Siemens LV 56 · 2008 50 600 600, 800 – 8PQ5000-2BA51 100 600 600, 800 – 8PQ5000-2BA52 1 150 600 600, 800 – 8PQ5000-2BA53 1 200 600 600, 800 – 8PQ5000-2BA54 1 250 600 600, 800 – 8PQ5000-2BA55 1 300 600 600, 800 – 8PQ5000-2BA56 1 350 600 600, 800 – 8PQ5000-2BA57 1 450 600 600, 800 – 8PQ5000-2BA58 1 550 600 600, 800 – 8PQ5000-2BA60 1 Internal Separation Modular Separation for Switching Devices ■ Description ■ Configuration Form 4 separation kit per Sentron 3VL in draw out version, consisting of horizontal, vertical and rear partitions. For each Sentron 3VL kit in draw out version, order 1 separation kit. ■ Selection and ordering data Circuit breaker No. of poles Height of module mm Width mm Cubicle depth mm Cable connection Ordering code UI 1 02115 Sentron 3VL, horizontal installation, form 4 separation VL160, VL250 3/4 250 600 400 front 8PQ5000-1BA76 VL400 3/4 300 600 400 front 8PQ5000-1BA77 1 VL630 4 350 600 400 front 8PQ5000-1BA80 1 VL630 3 300 600 400 front 8PQ5000-1BA81 1 VL160, VL250 3/4 250 600 600, 800 front, rear 8PQ5000-1BA82 1 VL400 3/4 300 600 600, 800 front, rear 8PQ5000-1BA84 1 VL630 3/4 1) VL160, VL250 3/4 350 600 400, 600, 800 front, rear 8PQ5000-1BA86 VL400, VL630 3/4 400 600 400, 600, 800 front 8PQ5000-1BA87 1 1 VL800 3/4 600 600 600, 800 front, rear 8PQ5000-1BA88 1 VL1250/VL1600 3/4 650 600 600, 800 front, rear 8PQ5000-2BA00 1 VL160, VL250 3/4 350 800 400, 600, 800 front, rear 8PQ5000-2BA01 1 VL400/630 3/4 400 800 400, 600, 800 front, rear 8PQ5000-2BA02 1 02117 02116 Sentron 3VL, pull-out, vertical installation, form 4 separation 8 1) siehe modulare Unterteilung Kapitel 8/13 Siemens LV 56 · 2008 8/13 Internal Separation Modular Separation for Switching Devices ■ Description ■ Configuration The “connecting terminal” kit achieves separation from form 4a to form 3b. In addition to the partitions, the required number of terminals (with or without copper busbars) has to be ordered. Separation from form 3b to form 4b is achieved through the combination of connecting terminal and protective bellows. When using the connecting busbar assembly kit for SENTRON 3VL circuit breakers, terminals need not be ordered. ■ Selection and ordering data Busbar mm × mm Ordering code UI 01716 01732 01683 Current A 2 × 25 × 5 1 × 30/40 × 10 Connecting terminal, separation installation from 4a to 3b – without busbar 8PQ5000-0BA05 4 250 A 2 × 25 × 5 8PQ5000-0BA72 2 400 A 1 × 30 × 10 8PQ5000-0BA73 4 630 A 1 × 40 × 10 8PQ5000-0BA74 4 – 8PQ9400-0BA03 4 Bellows, separation installation from 3b to 4b – 8 8/14 Siemens LV 56 · 2008 9 Air-Conditioning Products 9/2 Introduction 9/2 Filter Fans 9/3 Air-Conditioning/Cooling Units 9/4 Heat Exchangers 9/5 Fan Heaters 9/5 Thermostats Siemens LV 56 · 2008 Air-Conditioning Products Introduction ■ Overview When selecting the individual air-conditioning units, the following factors must be taken into account: ambient temperature, power dissipated from the devices installed, maximum admissible temperatures of the devices, heat dissipated via the cubicle, and degree of protection required. Switchgear may be subject to overheating, condensate or mould formation due to the presence of hot, cold or moist air in the immediate surroundings. In this case, the cubicle should be air-conditioned. The following air-conditioning units are available for this purpose: • Filter fans • Air-conditioning/cooling units • Heat exchangers • Heaters/thermostats The installation of air-conditioning devices improves the reliability of switchgear and controlgear, making for enhanced machine and system availability. Filter fans ■ Description ■ Configuration Using fans and equipping the switchgear enclosures with ventilation fins are the most economical methods to control the temperature inside a cubicle. However, the temperature reached inside the board is higher than ambient temperature. When adopting filter fans the temperature via the board enclosure must not be considered. Filter fans must be installed in the lower part of the board. If possible, outlet filters must be installed in the upper part, on the door or a side panel. The use of thermostats makes for longer filter fan and filter life. Outlet filters should be at least the same size as the cut-out made in the door for the filter fan. A simple formula to determine the quantity of air needed is: Air needed = 1,2 x Pv / ∆ t ∆ t = interior temperature - ambient temperature Pv = Installed power dissipated For an exact determination, computation software can be supplied on request. Notice - the standard colour is RAL 7032: special colour orders must be defined with -Z Z = specify the RAL. ■ Selection and ordering data Size V AC 9 Air flow-rate through free intake IP54 W/K Air flow-rate with outlet filter IP54 Exterior dimensions mm x mm Cut-out in door mm x mm Ordering code UI 15 (IP43) 15 (IP43) 43 43 108 108 231 231 368 368 437 437 105 x 105 105 x 105 150 x 150 150 x 150 250 x 250 250 x 250 250 x 250 250 x 250 325 x 325 325 x 325 325 x 325 325 x 325 92 x 92 92 x 92 125 x 125 125 x 125 223 x 223 223 x 223 223 x 223 223 x 223 291 x 291 291 x 291 291 x 291 291 x 291 8MR3101-0MA 8MR3101-0JA 8MR3102-0MA 8MR3102-0JA 8MR3103-0MA 8MR3103-0JA 8MR3104-0MA 8MR3104-0JA 8MR3105-0MA 8MR3105-0JA 8MR3106-0MA 8MR3106-0JA 1 1 1 1 1 1 1 1 1 1 1 1 346 (IP33) 540 (IP33) 417 x 367 530 x 350 345 x 265 345 x 265 8MR3140-1DA 8MR3180-1DA 1 1 105 x 105 150 x 150 250 x 250 325 x 325 92 x 92 125 x 125 223 x 223 291 x 291 8MR3111-0AA 8MR3112-0AA 8MR3113-0AA 8MR3115-0AA 1 1 1 1 Filter fans with standard filter mat for door-mounted installation 230 115 230 115 230 115 230 115 230 115 230 115 24 (IP43) 24 (IP43) 58 58 155 155 255 255 478 478 606 606 Filter fan for top plate installation with standard filter mat 230 230 450 (IP33) 800 (IP33) Outlet filter with standard filter mat for door-mounted installation 9/2 Siemens LV 56 · 2008 Air-Conditioning Products Air-Conditioning/cooling Units ■ Description ■ Applications Air-conditioners are used for ambient temperatures higher than the temperature admissible for the equipment installed in the cubicle. All the units work with FCC free cooling systemsAir-conditioners dehumidify the air inside the cubicle. Cooling units for door, side panel or roof mounting Two separate cooling circuits ensure that no hot air remains inside the cubicle. High-performance radial fans provide for effective air circulation inside the cubicle. Temperature controller with built-in thermostat (roof mounted). Side-panel mounted units Standard electronic components, technical characteristics: • Test module • Temperature limit • Time lat at start-up • Door contact function • Fault indicator contact • On-site diagnostics • UL approval. Notice - the standard colour is RAL 7032: special colours orders must be defined with -Z Z = specify the RAL. ■ Selection and ordering data Power W Voltage V Ordering code UI* Panel or door (flush) mounted air-conditioners 1000 230 1500 2000 400/440 2500 8MR5 510–1TE 1 piece 8MR5 515–1TE 1 piece 8MR5 520–1TE 1 piece 8MR5 525–1TE 1 piece 9 Filter fans with standard filter mat 320 115/320 8MR4 032–1SA 1 piece 500 8MR4 050–1SA 1 piece 820 8MR5 082–1SA 1 piece 1100 8MR5 110–1SA 1 piece 1400 8MR5 140–1SA 1 piece 1400 400/440 1800 2500 3200 230 5000 8MR5 144–1SA 1 piece 8MR5 180–1SA 1 piece 8MR5 250–1SA 1 piece 8MR4 320–2SB 1 piece 8MR4 500–2SB 1 piece Roof-mounted air-conditioners 810 230 1150 1600 3000 400 3200 400 5000 8MR5 081–1DA 1 piece 8MR5 115–1DA 1 piece 8MR5 160–1DA 1 piece 8MR5 300–1DA 1 piece 8MR4 320–2DB 1 piece 8MR4 500–2DB 1 piece * You can order this quantity or multiples thereof. Siemens LV 56 · 2008 9/3 Air-Conditioning Products Heat Exchangers ■ Description Air-air principle (8ME78) Air-water principle (8MR5) The heat exchangers working according to the air-air principle use two fully separate air circuits: an exterior circuit and an inner circuit. The heat exchangers working according to the air-water principle use 1 air circuit. A fan draws in cold air from the exterior. By means of another fan the hot interior air is conveyed to an element separated by laminas, which, in its turn, conveys the air onto the exterior circuit. A fan conveys the hot air inside the cubicle to the heat exchanger. In this manner, the heat is transferred to the cooling medium (water) and the temperature of the air inside the cubicle is reduced. Notice - the standard colour is RAL 7032: special colour orders must be defined with -Z Z = specify the RAL. ■ Selection and ordering data Version Voltage V Size Ordering code UI* Aluminium, not treated 220-240 16/06 8ME7 844-0 1 piece Painted RAL 7032 220-240 16/06 8ME7 844-1 1 piece Aluminium, not treated 220-240 20/06 8ME7 864-0 1 piece Painted RAL 7032 220-240 20/06 8ME7 864-1 1 piece Power W Voltage V H×W×D mm Ordering code UI* Heat exchangers 35 C° Hot air from the equipment Cubicle Cold air recirculation 25 C° NSE0_01391 Heat exchangers for side mounting 500 × 200 × 100 8MR5 065-2WS 1 piece 1000 500 × 200 × 100 8MR5 100-2WS 1 piece 1450 1350 × 390 × 189 8MR5 145-2WS 1 piece 1500 950 × 400 × 115 8MR5 150-2WS 1 piece 650 2450 230 230 3000 9 1350 × 390 × 189 8MR5 245-2WS 1 piece 950 × 400 × 190 8MR5 300-2WS 1 piece 4000 860 × 560 × 137 8MR5 400-2WS 1 piece 5000 1400 × 460 × 235 8MR5 500-2WS 1 piece Heat exchangers for roof mounting 1450 2100 230 600 × 390 × 140 8MR5 145-2WD 1 piece 720 × 465 × 190 8MR5 210-2WD 1 piece * You can order this quantity or multiples thereof. 9/4 Siemens LV 56 · 2008 Air-Conditioning Products Fan Heaters ■ Applications ■ Configuration Cubicle heaters are used to prevent malfunctions probably caused by condensation formation and corrosion phenomena as well as to maintain a minimum interior temperature. The design of the aluminium profile ensures even temperature distribution, making for optimised heating effects. To prevent corrosion problems, the difference between exterior and interior temperatures must be about 5K. The required heating power can be determined from the Pv /∆T diagram given in chapter 12/9. PHeizung = Pv x k3 x k4 x k5 x k6 ■ Selection and ordering data Power W Voltage V 10 110-250 Series Ordering code UI* Heaters 20 30 15 110-250 HGK047 8MR2 110-0B 2 pieces HGK047 8MR2 110-2B 2 pieces HGK047 8MR2 110-3B 2 pieces HG140 8MR2 130-1A 2 pieces 20 HG140 8MR2 130-3A 2 pieces 45 HG140 8MR2 130-4A 1 piece 60 HG140 8MR2 130-6A 1 piece 75 HG140 8MR2 130-7A 1 piece 100 HG140 8MR2 130-0A 1 piece 150 HG140 8MR2 130-5A 1 piece Thermostats ■ Applications The (NC/NO) thermostats installed in cubicles are used to control the interior temperature and make sure that the admissible temperatures of the devices are not exceeded. They are used to control the operation of cooling units, filter fans, heat exchangers. ■ Selection and ordering data Version Temperature °C Series Ordering code UI* 0 ... + 60 KTO 01140 8MR2 170-1BA 3 pieces – 10 ... + 50 KTO 01140 8MR2 170-1CA 3 pieces + 20 ... + 80 KTO 01140 8MR2 170-1DA 3 pieces 0 ... + 60 KTS 01141 8MR2 170-1BB 3 pieces – 10 ... + 50 KTS 01141 8MR2 170-1CB 3 pieces + 20 ... + 80 KTS 01141 8MR2 170-1DB 3 pieces + 20 ... + 80 ZR 011 8MR2 170-1E 2 pieces Thermostats NC NO Twin thermostat NC/NO Mechanical thermostats CO + 10 ... + 60 FZK 011 8MR2 170-1A 2 pieces – 20 ... + 30 FZK 011 8MR2 170-1B 1 piece * You can order this quantity or multiples thereof. Siemens LV 56 · 2008 9/5 9 Air-Conditioning Products Notes 9 9/6 Siemens LV 56 · 2008 10 Accessories 10/2 Fasteners 10/3 Miscellaneous Parts Siemens LV 56 · 2008 Accessories Fasteners ■ Selection and ordering data Description Ordering code UI 01719 Fasteners for mechanical connections Self-tapping screw DIN 7500 - M6x10 8PQ9500-0BA34 100 Self-tapping screw DIN 7500 - M6x16 8PQ9500-0BA32 100 Self-tapping screw DIN 7500 - M6x20 8PQ9500-0BA31 100 RAL7035 caps for self-tapping screws 8PQ9400-0BA14 100 Self-tapping hex-head screw DIN 7500 - M6x12 8PQ9500-1BA07 100 Description Ordering code UI Carriage bolt DIN 603 - M10x35 8PQ9500-0BA14 50 Carriage bolt DIN 603 - M10x45 8PQ9500-0BA16 50 Carriage bolt DIN 603 - M10x55 8PQ9500-1BA36 50 Carriage bolt DIN 603 - M10x65 8PQ9500-1BA25 50 Busbar connection kit for M10 screw 8PQ9400-0BA02 20 Description Ordering code UI 01743 01720 Fasteners for electrical connections, rectangular profiles 1 01742 Fasteners for busbar electrical connections, with H profiles H1 T-head screw - M10x25 8PQ9500-0BA01 100 T-head screw - M10x35 8PQ9500-0BA02 100 Description Ordering code UI Fasteners for electrical connections1 10 Hexagon-head screw ISO 4017 - M8x25 8PQ9500-0BA77 50 Hexagon-head screw ISO 4017 - M8x35 8PQ9500-0BA78 50 Hexagon-head screw ISO 4017 - M12x40 8PQ9500-0BA88 50 Hexagon-head screw ISO 4014 - M12x50 8PQ9500-0BA64 50 Hexagon-head screw ISO 4014 - M12x60 8PQ9500-1BA02 50 Hexagon-head screw ISO 4014 - M12x80 8PQ9500-1BA51 50 Hexagonal nut ISO 4032 - M8 8PQ9500-0BA07 50 Hexagonal nut ISO 4032 - M10 8PQ9500-0BA05 50 Hexagonal nut ISO 4032 - M12 8PQ9500-0BA04 50 Clamping washer DIN 6796 - 8 8PQ9500-0BA58 50 Clamping washer DIN 6796 - 10 8PQ9500-0BA60 50 Clamping washer DIN 6796 - 12 8PQ9500-0BA61 50 Washer DIN 125 - 8.4 8PQ9500-0BA70 50 Washer DIN 125 - 10.5 8PQ9500-0BA67 50 Washer DIN 125 - 13 8PQ9500-1BA33 50 Lock washer BN208012 - 8 8PQ9500-0BA48 50 Lock washer BN208012 - 10 8PQ9500-0BA50 50 Lock washer BN208012 - 12 8PQ9500-0BA51 50 1) For electrical connections make exclusive use of 8.8 strength class fasteners. 10/2 Siemens LV 56 · 2008 Accessories Miscellaneous Parts ■ Selection and ordering data Description Ordering code UI “SIVACON SIEMENS” ID plate 8PQ9400-0BA06 1 1/4 turn screws 8PQ9400-0BA17 20 Rotary handle with flat cylinder, hinged on left side 8PQ9400-0BA07 1 Button operated handle, lockable, hinged on left side 8PQ9400-0BA08 1 Semi-cylindrical profile acc. to DIN 18252/18254 8x45°, adjustable, various locks 8PQ9400-0BA26 1 Key with two-way locking mechanism, 3mm 8PQ9400-0BA12 10 Crossbar for installation in cubicle, 400mm wide Crossbar for installation in cubicle, 600mm wide Crossbar for installation in cubicle, 800mm wide Crossbar for installation in cubicle, 1000mm wide Crossbar for installation in cubicle, 1200mm wide Crossbar for installation in cubicle, 400mm deep, with side upright or 600mm, 800mm deep Crossbar for installation in cubicle, 600mm deep (without side upright) Crossbar for installation in cubicle, 800mm deep (without side upright) Universal mounting bracket 8PQ3000-0BA12 8PQ3000-0BA71 8PQ3000-0BA72 8PQ3000-0BA84 8PQ3000-0BA85 8PQ3000-0BA10 8PQ3000-1BA24 8PQ3000-1BA25 8PQ9400-0BA01 2 2 2 2 2 2 2 2 10 Cable bracket, C30 profile, cubicle depth 400mm, 600mm, 800mm Cable bracket, C30 profile, cubicle width 400mm Cable bracket, C30 profile, cubicle width 600mm Cable bracket, C30 profile, cubicle width 800mm Cable bracket, C30 profile, cubicle width 1000mm Cable bracket, C30 profile, cubicle width 1200mm Corner piece to fasten cable brackets 8PQ3000-0BA38 8PQ3000-0BA41 8PQ3000-0BA42 8PQ3000-0BA43 8PQ3000-0BA86 8PQ3000-0BA87 8PQ3000-0BA73 5 5 5 5 5 5 10 Double profile DIN rail, 35mm, L = 1600mm 8PQ9600-0BA01 1 Lifting eyebolts Lifting brackets for 400mm wide cubicle Lifting brackets for 600mm wide cubicle Lifting brackets for 800mm wide cubicle Lifting brackets for 1000mm wide cubicle Lifting brackets for 1200mm wide cubicle 8PQ9400-0BA11 8PQ3000-0BA88 8PQ3000-1BA00 8PQ3000-1BA01 8PQ3000-1BA02 8PQ3000-1BA03 4 2 2 2 2 2 02120 Column ID plate 00004 02122 02121 01717 02154 Door and special covers 01715 01669 01684 01682 01668 01681 Mechanical accessory parts Siemens LV 56 · 2008 10/3 10 Accessories Miscellaneous Parts ■ Selection and ordering data Description Ordering code UI Electrical accessories 8MF4900 1 Schuko socket max 250 V, with 6,3 A fuse, mounting on 35 mm DIN rail 8MF9300 1 Schuko socket max 250 V, without 16 A fuse, mounting on 35 mm DIN rail 8MF9005 1 Limit switch for single door, 1 NO/NC 8MF4310 1 Limit switch for double door, 1 NO/NC 8MF4311 1 Door grounding strip, 6mm2 8PQ9400-0BA15 10 Cable entry for segregation 8PQ9400-0BA16 20 Bit for Torx screwdriver M6 1/4” 50mm 8PQ9400-0BA05 5 Bit for Torx screwdriver M6 1/4” 200mm 8PQ9400-0BA10 2 Screwdriver with case and charger 8PQ9400-0BA22 1 Spray - RAL 7035 8GF9388-2 1 Spray basic blue-green colour 8PQ9400-0BA04 1 Solid frames for modular devices 12 UM 8GK9910-0KK00 1 Depth adapters for modular devices from 70 to 55mm deep 8GF9670-1 1 Cover for modular devices 5ST3800 1 Instrument plug 72mm x 72mm 8GF7770-4 1 Instrument plug 96mm x 96mm 8GF7770-5 1 Plastic diagram pocket DIN A4 8GD9132 ID stickers, L1, L2, L3, N, PE 8GK9920-0KK27 02155 02127 02126 02125 02124 Lamp with 11 W fluorescent tube, Schuko socket, On/Off switch and magnetic clamp 02156 Tools Repair paint Other parts 10 10/4 Siemens LV 56 · 2008 1 10 11 Mechanical Dimensions 11/2 Cubicle 11/3 Base and Enclosure 11/4 Enclosure 11/6 Busbar System 11/8 Terminals 11/9 Mounting Plates 11/10 Covers, modular doors 11/11 SIVACON 8PS Duct Connections 11/15 SENTRON 3VL with Motorised Operating Mechanism Siemens LV 56 · 2008 Mechanical Dimensions Cubicle ■ Structure 01750 W Width d Depth h Height 400 400 2000 600 600 800 800 1000 1200 ■ Floor anchoring of cubicle without base d L2 d L2 400 350,0 400 250,0 400 350,0 400 310,0 600 550,0 600 450,0 600 550,0 600 510,0 800 750,0 800 650,0 800 750,0 800 710,0 1000 850,0 1000 910,0 1200 1050,0 1200 1110,0 11/2 Siemens LV 56 · 2008 w L1 01753 01752 11 w L1 Mechanical Dimensions Base and Enclosure 01755 01754 ■ Base d L2 400 350,0 400 250,0 600 550,0 600 450,0 800 750,0 800 650,0 1000 850,0 1200 1050,0 w L1 ■ Door, rear and side panel, with and without design strip Rear panel Side panel without design strip 01756 01757 Side panel with design strip Door ■ Top plate upgraded to IP X1 11 Side view 01759 01758 Front view Siemens LV 56 · 2008 11/3 Mechanical Dimensions Enclosure 01762 ■ Top plate with cable entry 01763 11 11/4 Siemens LV 56 · 2008 Mechanical Dimensions Enclosure 01760 ■ Bottom plate with cable entry 01761 11 Siemens LV 56 · 2008 11/5 Mechanical Dimensions Busbar System 01764 01765 01767 ■ Main busbar systems in standard position 01766 ■ Busbar systems in free position ■ Grounding bar PE NSEX_00006 01768 11 11/6 Siemens LV 56 · 2008 Mechanical Dimensions Busbar System 01771 01772 ■ Vertical busbar systems, cascaded 01769 ■ Vertical busbar systems, non-cascaded 01770 11 Siemens LV 56 · 2008 11/7 Mechanical Dimensions Terminals 01783 01784 ■ Terminal ■ Busbar arrangement 01749 11 up to 250 A 11/8 Siemens LV 56 · 2008 up to 400 A up to 630 A Mechanical Dimensions Mounting Plates 01781 ■ Modular mounting plates, with and without holes 01778 01779 01777 Position L A 86,0 B 106,0 C 126,0 D 145,0 E 175,0 F 204,0 G 210,0 H 229,0 I 249,0 K 264,0 L 284,0 w L 600 253 800 353 w L ■ Galvanised chrome plate for electrotechnical applications 320 600 520 800 720 1000 920 1200 1120 01774 01773 01775 400 Siemens LV 56 · 2008 11/9 11 Mechanical Dimensions Covers, Modular Doors ■ Cover 02183 Cover Interior door or modular door 02129 02128 ■ Modular door 11 11/10 Position L A 170 B 190 C 210 D 229 E 259 F 288 G 294 H 313 I 333 K 330 L 368 Siemens LV 56 · 2008 Mechanical Dimensions SIVACON 8PS Duct Connections 02179 02180 ■ SIVACON 8PS with connections to top 02182 ■ SIVACON 8PS with connections to bottom 02181 11 Siemens LV 56 · 2008 11/11 Mechanical Dimensions SIVACON 8PS Duct Connections 02161 02160 ■ Cut-out in top plate for combination of RX duct with Sentron 3WL Gr I, 3, 4 poles and 3WL Gr. II, 3 poles ■ Cut-out in top plate for combination of LX duct with Sentron 3WL Gr I, 3, 4 poles and 3WL Gr. II, 3 poles 02163 02162 11 11/12 Siemens LV 56 · 2008 Mechanical Dimensions SIVACON 8PS Duct Connections 02165 02164 ■ Cut-out in top plate for combination of DX duct with Sentron 3WL Gr II, 3 and 4 poles ■ Cut-out in top plate for combination of duct LX05..., LX06..., LX07 with Sentron 3WL Gr. II, 3 and 4 poles 02167 02166 11 Siemens LV 56 · 2008 11/13 Mechanical Dimensions SIVACON 8PS Duct Connections 02169 02168 ■ Cut-out in top plate for combination of duct LX08... with Sentron 3WL gr. II, 3 and 4 poles 11 11/14 Siemens LV 56 · 2008 Mechanical Dimensions SENTRON 3VL with Motorised Operating Mechanism 02212 ■ Dimensions for equipment combination including, circuit breaker, removable or fixed door and motorised operating mechanism Equipment mounting plate installed in the deepest mounting position. For rear terminal bars, the use of rear vertical partitions is limited. Dimensions when set to ON * [mm] Above the cover A Above the cubicle B Above the inner door C VL 160-250 50 -12 -37 VL 400 72 10 -14 VL 630 111 48 23 VL 800 105 43 18 VL 1250/1600 126 62 37 * In sectioning position, the dimensions increase from 27 to 32mm. Take into account the additional space necessary to pull out the equipment. 11 Siemens LV 56 · 2008 11/15 Mechanical Dimensions Notes 11 11/16 Siemens LV 56 · 2008 12 Planning and Configuration 12/2 SIMARIS CFB 12/3 Configuration Procedure 12/4 Check List for SIVACON S4 12/6 Correction Factors 12/8 Internal Temperature of Low-Voltage Power Distribution Boards 12/10 Example Siemens LV 56 · 2008 Planning and Configuration SIMARIS CFB ■ Overview With SIMARIS CFB easy planning and programming SIMARIS CFB facilitates offer processing and project execution thanks to the following functions: • Management of project and customer data • Output functions: list of components, images, SingleLine, bid documents • Configuration of SIVACON S4 low-voltage distribution board with integrated selection of specific equipment and devices as a function of geographic location It is always possible to integrate new products, such as Alpha small distribution boards, at any time ■ Advantages • Easy to manage Windows interface • Integrated product database, updated by download • Rule-based configuration with choice of characteristics not depending on product • A detailed knowledge of products and systems is not required 12 • Possibility to make changes with ease at both offer and construction stage • Many output functions • Order placement by e-mail • Reduced workload • Price determination/calculation 12/2 Siemens LV 56 · 2008 Planning and Configuration Configuration Procedure ■ Overview The planning and configuration of low-voltage power distribution boards is an important, cost-determining factor within the scope of power distribution board construction. The following notes are based on a network calculated with a special procedure. This chapter is to support the manufacturer of power distribution boards with the planning and configuration of low-voltage power distribution boards. Additionally, the manufacturer has to comply with international standards and regional provisions. The terms used are explained in the Appendix. ■ Configuration procedure 1. Reading of specification and determination of characteristics (check list) - Network system, voltage level - Transformer power, input currents, short-circuit strength - Ambient temperature, degree of protection - Mounting type (single-front / back-to-back / free-standing / wall) - Arrangement of power distribution board / installation surface (operating and maintenance aisles, escape direction) - Type of connection (cable or busbar) - Access to cable, busbar connection (front, rear) - Cable/busbar entry (top, bottom) - Ambient conditions (condensation, chemical emissions) - Device installation systems (fixed, plug-in, withdrawable design) - Safety requirements (internal separation, resistance to internal arcs) - Date of delivery (tender / order) - Reserve 2. Configuration of power distribution board (conversion of characteristics into power distribution board technology) - Determination of the busbar system - Arrangement of incoming feeders and couplings - Determination of feeders - Feeder-section allocation 3. Optimisation of power distribution boards - Optimised space utilisation concerning: • Device selection • Feeder arrangement - Cost optimisation concerning: • Device selection • Busbar version (reduced cross-section with centre infeed) 4. Testing of power distribution board configuration - Determination of the power loss per section - Determination of the section's internal temperature - Verification that the section’s internal temperature <= max. ambient temperature of the applied devices - Determination of the reduction factors in accordance with the calculated ambient temperature of the applied devices - Verification that max. operating current <= rated current x reduction factor - If one of the conditions to be verified is not complied with, the power distribution board configuration has to be modified concerning • device selection • feeder arrangement and the tests must be repeated.. 12 Siemens LV 56 · 2008 12/3 Planning and Configuration Check List for SIVACON S4 ■ Check List for SIVACON S4 Project name: ______________________________________________________________________________________ Customer: _______________________________________________________________________________________ Planner: _______________________________________________________________________________________ Date of delivery:__________________ Installation site/height: _______ m (above MSL) Ambient temperatue: _______ °C Relative air humidity: ______________ % yer Condensation risk? no Harmful substance:_____________________________________ Mounting type: single-front back-to-back Degree of protection to interior: IP _______________ Degree of protection to cable floor: IP _______________ Requirements regarding resistence to internal arcs: yes wall free-standing Internal separation: form _____________ no which: _______________________ Maximum distribution board dimensions: W × H × D ______________ mm Maximum transport dimensions: W × H × D ______________ mm Network type: TN-S Cross-section PEN/N: Cross-section PE: TN-C Room height: __________ mm TN-C-S TT reduced ________% full 100% IEC acc. to type test 25% of external conductor cross-section Transformer power: ________________________ kVA Rated current of infeed: ________________________ A Frequency: ________________________ Hz Rated operating voltage: ________________________ V Rated short-time withstand current Icw (1 sec.) ________________________ kA 12 12/4 Siemens LV 56 · 2008 IT Planning and Configuration Check List for SIVACON S4 Infeeds Connection: busbar cable Access to calbe/busbar entry: from the front from the rear Cable / busbar entry: top bottom fixed-mounted withdrawable Intallation system for switching devices: Air circuit breakers(ACB): Molded case circuit breakers (MCCB) ≥ 630A: fixed-mounted withdrawable Molded case circuit breakers (MCCB) <= 630A: fixed-mounted withdrawable plug-in design fuseless fused Switch disconnectors (LBS) Remarks: fixed-mounted __________________________________________________________________________________ __________________________________________________________________________________ Feeders Connection: busbar cable Access to calbe/busbar entry: from the front from the rear Cable / busbar entry: top bottom fixed-mounted withdrawable Intallation system for switching devices: Air circuit breakers(ACB): Molded case circuit breakers (MCCB) ≥ 630A: fixed-mounted withdrawable Molded case circuit breakers (MCCB) <= 630A: fixed-mounted withdrawable plug-in design fuseless fused Switch disconnectors (LBS) Remarks: fixed-mounted __________________________________________________________________________________ __________________________________________________________________________________ Feeder reserve: _______________ % Empty space reserve: _______________ % Miscellaneous: __________________________________________________________________________________ __________________________________________________________________________________ Siemens LV 56 · 2008 12/5 12 Planning and Configuration Correction Factors ■ Rated currents and initial short-circuit AC currents of three-phase distribution transformers with 50 to 3150 KVA Rated voltage UcT 400/230, 50 Hz Rated value of the short-circuit voltage ukt 525 V, 50 Hz 4% 1) 6% 2) 690/400 V, 50 Hz 4% 1) 6% 2) 4% 1) 6% 2) Rated power Rated current Ir Initial short-circuit AC current Ik 3) Rated current Ir Initial short-circuit AC current Ik 3) Rated current Ir Initial short-circuit AC current Ik 3) kVA A A A A A A A A A 50 72 1933 1306 55 1473 995 42 1116 754 100 144 3871 2612 110 2950 1990 84 2235 1508 160 230 6209 4192 176 4731 3194 133 3585 2420 200 288 7749 5239 220 5904 3992 167 4474 3025 250 360 9716 6552 275 7402 4992 209 5609 3783 315 455 12247 8259 346 9331 6292 262 7071 4768 400 578 15506 10492 440 11814 7994 335 8953 6058 500 722 19438 13078 550 14810 9964 418 11223 7581 630 910 24503 16193 693 18669 12338 525 14147 800 1154 – 20992 880 – 15994 670 – 9349 1000 1444 – 26224 1100 – 19980 836 – 15140 1250 1805 – 32791 1375 – 24984 1046 – 18932 1600 2310 – 41857 1760 – 31891 1330 – 24265 2000 2887 – 52511 2200 – 40008 1674 – 30317 2500 3608 – 65547 2749 – 49941 2090 – 37844 3150 4550 – 82656 3470 – 62976 2640 – 47722 12120 1) ukr = 4%, standardised in accordance with DIN 42503 for Srt = 50 ... 630 kVA 2) ukr = 6%, standardised in accordance with DIN 42511 for Srt = 100 ... 1600 kVA 3) Ik Unaffected initial short-circuit AC current of the transformer upon connection to a network with unlimited short-circuit power considering the voltage factor and the correction factor of the transformer impedance in acc. with DIN EN 60909 I DIN VDE 0102 (July 2002) ■ Correction factors for installation heights over 2000 m above MSL The low air density at altitudes over 2000 m affects the electrical characteristics of the power distribution board. The rated currents are subject to the following correction factors for installation heights above 2000 m over MSL.. Correction factors for installation heights over 2000 m above MSL Altitude of installation site K1 for the load up to 2200 m 2400 m 2500 m 2700 m 2900 m 0,88 0,87 0,86 0,85 0,84 up to 3000 m 3300 m 3500 m 0,83 0,82 0,81 up to 4000 m 4500 m 0,78 0,76 up to 5000 m 0,74 In = In <= 2000 m x k1 12 ■ Reduced switching capacity for erection heights over 2000 m above MSL If the boards are erected at altitudes over 2000 m, the devices' reduced switching capacity must be taken into account. For the 12/6 Siemens LV 56 · 2008 correction factors, refer to the technical documents of the devices. Planning and Configuration Correction Factors ■ Correction factors for busbar systems at ambient temperatures of <> 35 °C The rated currents for main busbar and distribution busbar systems indicated in the catalogue refer to the ambient temperatures for indoor installation described in IEC/EN 60439-1. Consequently, the ambient temperature for low-voltage power distribution boards does not exceed +40 °C and the average value of a period of 24 h is not higher than +35 °C. For ambient temperatures, whose average value deviates from this ambient temperature, the following correction factors must be observed. 1,15 1,1 1,05 K2 1 0,95 1 0,9 2 0,85 0,8 15 20 25 30 35 40 45 50 55 Ambient temperature [°C] (1) Main busbars (2) Vertical disribution busbars In = In 35 °C x K2 ■ Correction factors for devices At ambient temperatures of >40 °C, the rated operating current has to be derated for devices. The ambient temperature of the devices complies with the internal temperature of the lowvoltage power distribution boards at the installation site. For the correction factors, refer to the technical documents of the devices. 12 Siemens LV 56 · 2008 12/7 Planning and Configuration Internal Temperature of Low-Voltage Power Distribution Boards ■ Determination of the internal temperature of low-voltage power distribution boards With a calculation in accordance with IEC 60890, the internal temperature of low-voltage power distribution boards can be specified on the basis of the total power loss and the system structure. 1. Power loss of busbar systems per section For the determination of the power loss of main busbars and distribution busbar systems, the operating current [A] on the respective length [m] has to be specified. The power loss assigned to the respective busbar configuration is illustrated in the following diagram. Main busbar systems 1000 800 Pv [W/m] 2 600 4 3 1 400 (1) 2x(20x10) mm2 (2) 2x(30x10) mm2 (3) 4x(20x10) mm2 (4) 4x(30x10) mm2 200 0 0 500 1000 1500 2000 2500 I [A] 1200 7 Pv [W/m] 1000 6 8 800 5 600 400 (5) 4x(40x10) mm2 (6) 4x(50x10) mm2 (7) 2x4x(20x10) mm2 (8) 2x4x(30x10) mm2 200 0 0 500 1000 1500 2000 2500 3000 3500 4000 I [A] Distribution busbar systems 600 500 9 10 Pv [W/m] 11 400 12 300 200 (9) DIN rail 30x30 mm (10) DIN rail 40x30 mm (11) 2x(30x10) mm2 (12) 2x(40x10) mm2 100 12 0 0 200 400 600 800 1000 1200 1400 I [A] PV Main busbar system = PV [W/m] x Länge [m] = PV [W/m] x Länge [m] PV Distribution busbar system PV Busbar system/section= PV main busbar system+ PV distribution busbar system 12/8 Siemens LV 56 · 2008 Planning and Configuration Internal Temperature of Low-Voltage Power Distribution Boards ■ Determination of the internal temperature of low-voltage power distribution boards 2. Power loss of devices per section 4. Determination of the section’s internal temperature For the power loss, refer to the technical documents of the devices. In this context, the actual utilisation (operating current, temporal simultaneousness, rated load factor) has to be observed. The diagram below illustrates the correlation between the installed power loss and the temperature difference, based on the calculation procedure of IEC 60890 as well as the specific data of SIVACON S4. The diagram refers to a section in degree of protection IP55 which is installed side-by-side with a free roof and rear panel. In case of deviating conditions, the correction factors of the following table have to be considered. For terminal bars, cables and lines as well as for small devices, a percentage increase of 10% has to be considered. Ir = operating current In = rated current PV device = PV devicet x (Ir / In)2 PV device / section = total (PV device) x 1,1 3. Installed power loss per section The installed power loss per section is the sum of the power loss of busbar systems and devices. PV section = PV busbar system / section+ PV device/section Ventilated section Degree of protection <= IP4X k3 Section with free side panel k4 1,65 1,09 Roof not free Rear panel not free k5 k6 0,95 0,92 PV section PV = k3 x k4 x k5 x k6 40,0 35,0 1 30,0 2 3 4 25,0 5 7 6 dT [K] PVn device = power loss device at rated current 8 20,0 15,0 10,0 5,0 0,0 0 100 200 300 400 500 Pdiss [W] Height x width x depth [mm] of the section (1) 2000x400x600 (2) 2000x400x800 (3) 2000x600x400 (4) 2000x600x600 (5) 2000x600x800 (6) 2000x800x400 (7) 2000x800x600 (8) 2000x800x800 The determined temperature difference refers to the average height in the section. The temperature linearly increases from the average section height to the complete section height with sufficient accuracy and has to be specified for SIVACON S4 with a correction factor of 1.4. Internal temperature in average section height [°C] = Ambient temperature of the power distribution board [°C] + temperature difference dT [K] Internal temperature in complete section height [°C] = Ambient temperature of power distribution board [°C] + Temperature difference dT [K] x 1.4 Siemens LV 56 · 2008 12/9 12 Planning and Configuration Example ■ Example for a power distribution board configuration test Power distribution board data Determination of the power loss per section Rated operating voltage Ue Rated short-time current Icw Rated load factor Degree of protection Ambient temperature Section height Base height Section depth Cable connection infeed Cable connections outputs 400V / 50Hz 35kA 0.8 IP40 35 °C 2000mm 100mm 600mm from the top rear bottom (rear panel free) PV section 1 = (PV busbar system section 1 + PV device section 1) x 1,1 = 743,81 W PV section 2 = (PV busbar system section 2 + PV device section 2) x 1,1 = 354,82 W Determination of the internal temperature Factors section 1 k3 1.65 k4 1.09 k5 0.85 k6 1 Front view Factors section 2 k3 1.65 k4 1.09 k5 1 k6 1 PV section 1 = PV section 2 = 486.56 W 197.29 W Internal temperature in acc. with diagram page 12/9 Temperature difference in half section height section 1 Temperature difference in half section height section 2 22 K 12 K Internal temperature in half section height for section 1 Internal temperature in half section height for section 2 57 °C 47 °C Internal temperature in section height for section 1 Internal temperature in section height for section 2 66 °C 52 °C Configuration test According to the technical documents of the devices, the limit temperatures are not exceeded. 01625 The devices are able to carry the specified rated currents. Determination of the power loss of the busbar systems per section In × 0,8 [A] Section 1 Lenght [m] PV busbar system [W/m] PV busbar system [W] 200 0,45 8 520 0,2 50 10 904 0,3 160 48 704 0,25 100 25 PV busbar section 1 = 3,6 86,6 W Determination of devices power lass per section 12 Section 1 Section 2 Location In [A] In x 0,8 [A] PV device max [W] PV device [W] Infeed 01.D1 1424 – 825 495.06 Output 01.J1 250 200 80 51.20 Output 01.K1 250 200 80 51.20 Output 02.D1 250 200 80 51.20 Output 02.F1 400 320 170 108.80 Output 02.K2 630 504 254 162.56 PV device section 1 = 597.46 W x 1.1 = 657.21 W PV device section 2 = 322.56 W x 1.1 = 354.82 W 12/10 Siemens LV 56 · 2008 13 Appendix 13/2 Glossary 13/8 Order Information 13/10 Standards and Approvals 13/11 Quality Management 13/12 Online Services 13/13 Customer Support 13/14 Training 13/15 Subject Index 13/16 Conditions of Sale and Delivery, Export Regulations Siemens LV 56 · 2008 Appendix Glossary ■ Rated values/definitions The terms defined below are used in the present catalogue in accordance with IEC 60439-1 and EN 60439-1. Section panel IEC/EN 60439-1; 2.2.2 Low-voltage switchgear and controlgear assembly IEC/EN 60439-1; 2.1.1 Component of a switchgear and controlgear assembly positioned between two superimposed horizontal limiting levels inside a section. Assembly of one or more switching devices combined with corresponding operating equipment for control, measuring and signalling tasks and with protective and control devices, etc. The individual devices are completely assembled by the manufacturer, including all internal electrical and mechanical connections and construction components. Type-tested low-voltage switchgear and controlgear assembly (TTA) IEC/EN 60439-1; 2.1.1.1 Low-voltage switchgear and controlgear assembly which complies with the original type or system of the switchgear and controlgear assembly type-tested in accordance with this standard without significant deviations. Functional unit IEC/EN 60439-1; 2.1.5 Part of a switchgear and controlgear assembly with all electrical and mechanical components which contribute to the execution of the same function. Cubicle IEC/EN 60439-1; 2.4.1 Component of a switchgear and controlgear assembly which serves the accommodation of various components of a switchgear and controlgear assembly or of an enclosure. Section IEC/EN 60439-1; 2.2.1 Compartment IEC/EN 60439-1; 2.2.3 Section or section panel which is encased with the exception of openings required for connection, control or ventilation. Transport unit IEC/EN 60439-1; 2.2.4 Part of a switchgear and controlgear assembly or complete switchgear and controlgear assembly which is not disassembled for transportation. Rated diversity factor IEC/EN 60439-1; 4.7 The rated diversity factor of a switchgear and controlgear assembly or of a component of a switchgear and controlgear assembly (e.g. section, section panel) which comprises several main circuits is the ratio of the largest sum of all currents which are to be expected in the respective main circuits at any given time to the sum of the rated currents of all main circuits of the switchgear and controlgear assembly or of the affected part of the switchgear and controlgear assembly. If the manufacturer states a rated diversity factor, this value must be taken as a basis for the temperature-rise test. Number of main current circuits Rated diversity factor 2 and 3 4 and 5 6 up to and including 9 10 uand more 0.9 0.8 0.7 0.6 Component of a switchgear and controlgear assembly positioned between two successive vertical limiting levels. Rated values In accordance with IEC/EN 60439-1;4, the manufacturers of lowvoltage switchgear and controlgear assemblies state rated values. These rated values apply to the specified operating conditions and characterise the usability of switchgear and controlgear assemblies. The coordination of the operating equipment or the configuration of the switchgear and controlgear assemblies must be based on these rated values. Rated short-time withstand current (Icw) IEC/EN 60439-1; 4.3 As the effective short-circuit current value, the rated short-time withstand current characterises the thermal strength of switchgear and controlgear assembly circuits during a short-time load. The rated short-time withstand current is normally determined for the duration of 1 sec; deviating time values must be indicated. The rated short-time withstand current is stated for the distribution and/or main busbars of switchgear and controlgear assemblies. Rated peak withstand current (Ipk) IEC/EN 60439-1; 4.4 13 As peak value of the peak current, the rated peak withstand current characterises the dynamic strength of switchgear and controlgear assembly circuits. The rated peak withstand current is stated for the distribution and/or main busbars of switchgear and controlgear assemblies. 13/2 Siemens LV 56 · 2008 Rated conditional short-circuit current (Icc) IEC/EN 60439-1; 4.5 The rated conditional short-circuit current corresponds to the uninfluenced short-circuit current which a circuit of the switchgear and controlgear assembly, that is protected by short-circuit protective devices, may carry without damage (for a limited time). The rated conditional short-circuit current is therefore stated for outgoing and/or incoming feeders, e.g. with circuit breakers. Rated impulse withstand voltage (Uimp) IEC/EN 60947-1; 4.3.1.3 Parameter for the resistance of clearances inside switching devices to impulse overvoltages. The application of suitable switching devices prevents disconnected system parts from transmitting overvoltages from the network in which they are applied. Appendix Glossary Rated current (In) (of circuit breakers) IEC/EN 60947-2; 4.3.2.3 Rated continuous current (Iu) IEC/EN 60947-1; 4.3.2.4 Current which, for circuit breakers, corresponds to the rated continuous current and the conventional thermal current. ➔ Rated continuous current Current which can be carried by switching devices in continuous operation (for weeks, months or years). Rated control voltage (Uc) IEC/EN 60947-1; 4.5.1 Rated making capacity IEC/EN 60947-1; 4.3.5.2 Voltage applied to the actuating NO contact of a control circuit. It may deviate from the rated control supply voltage if transformers or resistors are connected to the control circuit. Current which can be switched on by switching devices with the respective rated operating voltage in accordance with the utilisation category. ➔ Rated operating voltage Rated ultimate short-circuit breaking capacity (Icu) IEC/EN 60947-2; 4.3.5.2.1 Rated frequency IEC/EN 60947-2; 4.3.3 Maximum short-circuit current which can be interrupted by a circuit breaker (test O – CO). After a short-circuit switch-off, the circuit breaker is able to trip with increased tolerances in the case of overload. Frequency for which switching devices are dimensioned and to which the other characteristic data refer. ➔ Rated operating voltage, rated continuous current Rated service short-circuit breaking capacity (Ics) IEC/EN 60947-2; 4.3.5.2.2 The short-circuit current depending on the rated operating voltage which can be repeatedly interrupted by a circuit breaker (test O – CO – CO). After the short-circuit breaking, the circuit breaker is able to continue to carry the rated current in the case of increased selfheating and to trip in case of overload. ➔ Rated continuous current ➔ Rated operating voltage Rated insulation voltage (Ui) IEC/EN 60947-1; 4.3.1.2 Voltage to which the insulation tests and creepage distances refer. The maximum rated operating voltage must, in no case, exceed the rated insulation voltage. ➔ Rated operating voltage Rated short-circuit breaking capacity (Icn) IEC/EN 60947-1; 4.3.6.3 Rated operating capacity IEC/EN 60947-1; 4.3.2.3 Maximum current which can be switched off by switching devices with the rated operating voltage and frequency without causing damage. The value is stated as effective value. ➔ Rated operating voltage Capacity which can be switched by switching devices with the assigned rated operating voltage in accordance with the utilisation category, e.g. power contactor of utilisation category AC-3: 37 kW at 400 V. Rated short-circuit breaking capacity (Icm) IEC/EN 60947-1; 4.3.6.2 Rated operating voltage (Ue) IEC/EN 60947-1; 4.3.1.1 Voltage to which the characteristic values of switching devices are referred to. The maximum rated operating voltage must, in no case, exceed the rated insulation voltage. ➔ Rated insulation voltage Maximum current which can be switched on by switching devices with a certain rated operating voltage and frequency without causing damage. Deviating from the other characteristic data, the value is stated as peak value. ➔ Rated operating voltage Rated operating current (Ie) IEC/EN 60947-1; 4.3.2.3 Current which can be carried by switching devices in consideration of the rated operating voltage, the operating time, the utilisation category and the ambient temperature. ➔ Rated operating voltage 13 Siemens LV 56 · 2008 13/3 Appendix Glossary ■ Ambient conditions / Degrees of protection The climate and external ambient conditions (natural impurities, toxic chemically active substances, small animals) may have severe repercussions on the functionality of electrical systems. The effect depends on the climatic protection of the room in which the system is installed. In the presence of high concentrations of toxic substances it is advisable to adopt appropriate measures to reduce them, for example: – Intake of air from an area with a lower pollution level – Exposing the area to a mild overpressure (e.g., introducing non polluted air into the system) – Climate control of the room where the system is installed (reducing the temperature, relative humidity of the air < 60%, possible installation of a purifying filter) – Attenuation of overheating (overdimensioning of electrical equipment and components such as main busbars and distribution busbars) Ambient conditions Class Classification of ambient conditions with the relative limit values (defined according to standard IEC 60721-3-3) Measurements Climatic 3K4 Minimum temperature of the air Maximum temperature of the air – Minimum relative humidity of the air Maximum relative humidity of the air Minimum absolute humidity of the air Maximum absolute humidity of the air Temperature variation rate Minimum air pressure Maximum air pressure Solar radiation Thermal radiation Movement of the air Condensate formation Matter deposited by the wind Water (other than rain) Ice accumulation Other ambient climatic conditions Biological 3Z1 Thermal radiation is negligible 3Z7 3Z9 3Z10 Water drops as defined in standard IEC 60068-2-18 Water spray as defined in standard IEC 60068-2-18 Water jets as defined in standard IEC 60068-2-18 3B2 – 5 °C 1) + 40 °C + 35 °C (24h-Mittel) 2) 5% 95 % 1 g/m_ 29 g/m_ 0,5 °C/min 70 kPA 106 kPA 700 W/m2 – 1,0 m/s possible Provide heating, if frequent 1 per day for 2 hours No See other ambient climatic conditions No IPX1 IPX4 IPX5 Flora Mold formation Fauna Presence of rodents and other harmful animals, other than termites IP4X, including protection for technical floors Chemically active substances 3C3 Marine salt Sulphurous anhydride SO2 Hydrogen sulphide H2S Chlorine Cl2 Hydrogen chloride HCl Hydrofluoric acid HF Ammonia NH3 Ozone O3 Nitrogen oxide NOx Salt mist ≤ 2 mg/dm2 5,0 mg/m3 (2 ppm) 3,0 mg/m3 (2 ppm) 0,3 mg/m3 (0,1 ppm) 1,0 mg/m3 (0,7 ppm) 0,1 mg/m3 (0,06 ppm) 10,0 mg/m3 (14,3 ppm) 0,1 mg/m3 (0,05 ppm) 3,0 mg/m3 (1,66 ppm) Mechanically active substances 3S1 Sand in the air Dust (matter in suspension) Dust (matter deposited) – 0,01 mg/m3 0,4 mg/(m2 * h) < IP5X 3S3 Sand in the air Dust (matter in suspension) Dust (matter deposited) 300 mg/m3 0,4 mg/m3 15 mg/(m2 * h) ≥ IP5X 1) According to standard IEC60721-3-3 the minimum admissible air temperature is + 5° C 2) Higher values can be admitted on request (see dimensioning tables) 13 13/4 Siemens LV 56 · 2008 Appendix Glossary ■ Network systems Distribution systems (network types) in acc. with IEC 60364-3 (DIN VDE 0100-300) Determination of protective measures and selection of the electrical operating equipment according to the distribution system. L1 TN systems L2 TN-S system The neutral conductor and protective conductor function are consistently separated in this system. L3 N PE 1 L1 TN-C system The neutral conductor and protective conductor function are composite throughout the entire system. L2 L3 PEN 1 L1 TN-C-S system Combination of the neutral and the protective conductor function. In one part of the system, they are composite in one conductor, while they are separated in another part. L2 L3 PEN PE N 13 1 1 Body Siemens LV 56 · 2008 13/5 Appendix Glossary ■ Network systems Distribution systems (network types) in acc. with IEC 60364-3 (DIN VDE 0100-300) Determination of protective measures and selection of the electrical operating equipment according to the distribution system. L1 TT system In the TT system, one point is directly earthed; the elements of the electrical system are connected to earth electrodes which are separated from the signal earth. The TT system corresponds to the system in which today the protective measures protective earthing, RCCB and fault-voltage circuit breaker are applied. L2 L3 N PE 1 L1 IT system The IT system features no direct connection between active conductors and earthed parts; the elements of the electrical system are earthed. The IT system corresponds to the system in which today the protective conductor system protective measure is applied. L2 L3 2 PE 1 1 Body 2 Impedance First letter = Earthing condition of the supplying current source Second letter = Earthing condition of the elements of the electrical system Further letters = Arrangement of the neutral and the protective conductor T = Direct earthing of one point I = Either insulation of all active parts of the earth or connection of one point to the earth via impedance T = Elements are directly earthed, irrespective of a possible earthing of one point of the current supply N = Elements are directly connected to the signal earth; in AC current networks, the earthed point is generally the star point S = Neutral and protective conductor function by means of separated conductors C = Neutral and protective conductor function combined in one conductor (PEN) 13 13/6 Siemens LV 56 · 2008 Appendix Glossary ■ Operating and maintenance aisles 2000 1) (in acc. with DIN VDE 0100 Part 729) 500 700 600 700 700 700 1) Minimum passage height beneath covers or casings. ■ Minimum passage height beneath covers or casings. Minimum aisle width 700 or 600 mm Escape direction Free minimum clearance 500 mm 1) 2) 1) With opposing power distribution board fronts, constriction by open doors (i.e. doors which do not close towards the escape direction) is only accounted for on one side. 2) Door widths must be observed, i.e. a minimum door opening angle of 90°. 13 Siemens LV 56 · 2008 13/7 Appendix Order Information ■ Logistics General Packaging, packing units Our logistics service offers “quality from the order to the delivery” pertaining to delivery service, communication and environmental protection. To maintain this high quality, we focus on the optimisation of the logistical procedures on the basis of a customised infrastructure and automatic DP order processing. Our device and shipping packagings offer protection against dust and mechanical damage during transport, thus ensuring that the customer receives the devices in a flawless condition. When selecting and designing our packagings, we set great value upon environmental compatibility, re-usability (e. g. crumpled paper instead of styrofoam chips as transport protection in shipping packages up to 32 kg) and above all, upon waste prevention. We attach major importance to personal support, deliveries in due time and area-wide transportation. The DIN-ISO-9001 certification and a consistent quality management are vital issues for us. The automatic DP order processing is fast, cost-effective and fail-safe. If you would like to exploit these benefits, please do not hesitate to contact us. 13 13/8 Siemens LV 56 · 2008 Unless otherwise stated in the selection and ordering data of this catalogue, our devices are supplied in separate individual packages. The device order numbers can be easily identified by means of the EAN bar code, which simplifies both order and warehouse logistics. The low-voltage controls and distribution master data include the allocation of order numbers and EAN code for data processing. Appendix Order Information ■ Ag and Cu surcharges Surcharges for copper (Cu) and silver (Ag) will be added to the prices of certain products. The amount of the surcharge depends on the percentage taken from the current list price. Calculation of the surcharges is governed by the official Ag quotation for refined silver and the applicable Cu-DEL quotation on the date of receipt of order or of call-off. ■ Small orders When small orders are placed, the costs associated with order processing are greater than the order value. We recommend therefore that you combine several small orders. Where this is not possible, we unfortunately find it necessary to charge a processing supplement of € 20.-- to cover our costs for order processing and invoicing for all orders with a net goods value of less than € 250.--. The prices for products include the price of copper calculated on the basis of a list price of € 150/100 kg. ■ Orders for special designs For ordering products that differ from the versions listed in the catalog, the order number specified in the catalog must be supplemented with “–Z”; the required features must be specified by means of the alphanumeric order codes or in plain text. 13 Siemens LV 56 · 2008 13/9 Appendix Standards and Approvals ■ CE mark of conformity Manufacturers of products which fall within the subject area to which EU directives apply must identify their products, instruction manuals or packaging with a CE mark of conformity. The CE mark of conformity confirms that a product fulfills the appropriate basic requirements of all pertinent directives. The mark of conformity is a mandatory requirement for putting products into circulation throughout the EU. All the products in this catalog are in conformance with the EU directives and bear the CE mark of conformity. • Low-voltage directive (NS 73/23/EU) • EMC directive (EMC 89/336/EU) The manufacturer of the system assembled from individual modules is responsible for the preparation of the EC declaration of conformity. ■ ALPHA/LOVAG The Low-Voltage Controls and Distribution Division of Siemens AG is a member of the "Gesellschaft zur Prüfung und Zertifizierung von Niederspannungsgeräten e.V. ALPHA" (Society for Testing and Certification of Low-Voltage Equipment), Frankfurt am Main. The responsibility of manufacturers and the high quality of products are promoted by ALPHA by means of supportive procedural guidelines for testing equipment according to the currently valid standards. Providing specific conditions are fulfilled, ALPHA can also issue officially recognized product certificates if required. As a member of LOVAG, ALPHA is also working towards obtaining international recognition for declarations of conformity and certificates. LOVAG (Low-Voltage Agreement Group) is a body comprising international specialists from certification bodies and industry who are working together to create a standardized European certificate. 13 13/10 Siemens LV 56 · 2008 List of LOVAG members ALPHA ASEFA ACAE CEBEC Intertek Semko AB APPLUSS Germany France Italy Belgium Sweden Spain Appendix Quality Management ■ Quality management The quality management system of our A&D division complies with the international standard EN ISO 9001. The products and systems described in this catalog are sold under application of a quality management system certified by DQS and TÜV Management Service GmbH in accordance with ISO 9001. The certificates are recognized in all IQ Net countries. DQS Registered Certificate Nos.: Siemens AG Automation and Drives • Industrial Automation Systems Reg. No.: 001323 QM • Industrial Communication SIMATIC NET Reg. No.: 002613 QM. TÜV (German Technical Inspectorate) Registered Certificate No.: Siemens AG Automation and Drives • Low-Voltage Controls Reg. No.: 12 100 16950 TMS. BVQI Registered Certificate No.: Siemens AG Automation and Drives • Electrical Installation Technology Reg. No.: 117779 13 Siemens LV 56 · 2008 13/11 Appendix Online-Services ■ A&D in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. The Siemens Automation and Drives Group (A&D) has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address http://www.siemens.com/automation you will find everything you need to know about products, systems and services. ■ Product selection using the Offline Mall of Automation and Drives Detailed information together with convenient interactive functions: The Offline Mall CA 01 covers more than 80,000 products and thus provides a full summary of the Siemens Automation and Drives product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the interactive catalog CA 01 can be found on the Internet under http://www.siemens.com/automation/ca01 or on CD-ROM and DVD.. ■ Easy shopping with the A&D Mall The A&D Mall is the virtual department store of Siemens AG in the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the A&D Mall on the Internet under: http://www.siemens.com/automation/mall 13 13/12 Siemens LV 56 · 2008 Appendix Customer Support ■ Configuration and software engineering Support in configuring and developing with customeroriented services from actual configuration to implementation of the automation project.2) ■ Technical support .I Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. In the face of harsh competition you need optimum conditions to keep ahead all the time: A strong starting position. A sophisticated strategy and team for the necessary support - in every phase. Service & Support from Siemens provides this support with a complete range of different services for automation and drives. Tel.: +49 (0) 180 50 50 222 Fax: +49 (0) 180 50 50 223 In every phase: from planning and startup to maintenance and upgrading. http://www.siemens.com/ automation/support-request Our specialists know when and where to act to keep the productivity and cost-effectiveness of your system running in top form. ■ Service on site ■ Online support With service on site we offer services for startup and maintenance, essential for ensuring system availability. The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop. http://www.siemens.com/ automation/service&support ■ Technical consulting Tel.: +49 (0) 180 50 50 444 2) ■ Repairs and spare parts Support in the planning and designing of your project from detailed actual-state analysis, target definition and consulting on product and system questions right to the creation of the automation solution.2) Technical assistance Expert technical assistance1) for Low-voltage controls and electrical installation. Tel.: +49 (0) 9 11 8 95-59 00 Fax: +49 (0) 9 11 8 95-59 07 In the operating phase of a machine or automation system we provide a comprehensive repair and spare parts service ensuring the highest degree of operating safety and reliability. Tel.: +49 (0) 180 50 50 446 2) ■ Optimization and upgrading To enhance productivity and save costs in your project we offer high-quality services in optimization and upgrading.2) E-Mail: technical-assistance @siemens.com 1) Contact: Technical assistance for product selection · Old/new coding · Competitor coding · Special versions · Special requirements · Sales promotion (Infoline). Your regional contacts for sales support (prices, discounts, delivery times). Technical Support for commissioning support and after-sales service. 2) For country-specific telephone numbers go to our Internet site at: http://www.siemens.com/automation/service&support 13 Siemens LV 56 · 2008 13/13 Appendix Training ■ Training is decisive for your success SITRAIN® - the Siemens Training for Automation and Industrial Solutions - provides you with comprehensive support when solving your tasks. Training by the market leader in automation, plant installation and support permits you to make your decisions with certainty and full command. Especially where the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in existing plants, and exclude expensive faulty planning right from the beginning. All in all, this represents an enormous gain for your company: shortened startup times, optimized plant components, faster troubleshooting, reduced down times. In other words, increased profits and lower costs. ■ The right mixture: Blended Learning Blended learning is understood to be the combination of various training media and sequences. For example, a local attendance course in a Training Center can be optimally supplemented by a teach-yourself program as preparation or follow-up. Furthermore, SITRAIN utilizes supported online training for live instruction on the Internet at agreed times. The right mixture is the solution. Therefore blended learning can convey complex topics well, and train networked thinking. Additional effect: reduced travelling costs and periods of absence through training sequences independent of location and time. ■ The international training portal http://www.siemens.com/sitrain All training facilities at a glance: search in the worldwide range of courses at leisure, call up all course dates online, utilize the daily updated display of vacant course spaces - and register directly. ■ Customer comments on Sitrain " ... the good course documents, competence and flexibility convinced me.” [Manfred Riek from Festo Systemtechnik, responsible for planning the basic and further training of project engineers] " ... represents effective training, constructive dialogs, and solutions which provide great help." [Günter Niedermaier, electrical design manager at AMT, Aalen] ■ Contact Visit us on the Internet at: http://www.siemens.com/sitrain or let us advise you personally. You can request our latest training catalog from: Top trainers Our trainers know their topics in practice, and possess comprehensive didactic experience. Course developers have a direct wire to product development, and directly pass on their knowledge to the trainers. Practical experience The practical experience of our trainers makes it possible for them to pass on theoretical matter in a plausible manner. But since it is known that all theory is drab, we attach great importance to practical exercises which can comprise up to half of the course time. You can therefore immediately implement your new knowledge in practice. We train you on state-of-the-art methodically/didactically designed training equipment. You feel absolutely certain when trained in this manner. Wide variety With a total of approx. 300 local attendance courses, we train the complete range of A&D products and a large portion of the system solutions from I&S. Telecourses, teach-yourself software and seminars presented on the Web supplement our classical range of courses. Close to our customers 13 The distance is short. You can find us approx. 60 times in Germany, and worldwide in 62 countries. You wish to have individual training instead of one of our 300 courses? No problem: we will provide a program tailored exactly to your personal requirements. Training can be carried out in our Training Centers or at your company. 13/14 Siemens LV 56 · 2008 Course office, Infoline Germany: Tel.: +49 (0)1805 / 23 56 11 (0.12 €/Min) Fax: +49 (0)1805 / 23 56 12 Appendix Subject Index 13 Siemens LV 56 · 2008 13/15 Appendix Terms and conditions of sale and delivery Export regulations ■ Terms and conditions of sale and delivery By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The “General Terms of Payment” as well as the “General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany” shall apply. For customers with a seat or registered office outside of Germany The “General Terms of Payment” as well as the “General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, especially with regard to data, dimensions and weights given these are subject to change without prior notice. The prices are in € (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products. 13 13/16 Siemens LV 56 · 2008 An exact explanation of the metal factor and the text of the Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: • 6ZB5310-0KR30-0BA1 (for customers based in Germany) • 6ZB5310-0KS53-0BA1 (for customers based outside Germany) or download them from the Internet http://www.siemens.com/automation/mall (Germany: A&D Mall Online-Help System) ■ Export regulations The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Number of the German Export List Products marked other than “N” require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “AL“ not equal to “N” are subject to a European or German export authorization when being exported out of the EU. ECCN Export Control Classification Number Products marked other than “N” are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “ECCN“ not equal to “N” are subject to a US re-export authorization. Even without a label or with an “AL: N” or “ECCN: N”, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. A&D/VuL_ohne MZ/En 05.09.06