Solid State Auto Switches General Purpose Type, 2-color Indication Type, 2-color Indication Type with Diagnostic Output, Water Resistant 2-color Indication Type, Hygienic Type, Timer Equipped Type, Magnetic Field Resistant Type, Heat Resistant Type, Wide Range Detection Type, Trimmer Auto Switch Solid State Auto Switch Variations Type Function Auto switch mounting style Electrical entry Auto switch model D-M9N/M9P/M9B D-M9NV/M9PV/M9BV General purpose Direct 2-color indication 2-color indication with diagnostic output Water resistant 2-color indication Trimmer Wide Heat Magnetic field Auto range resistant resistance Switch detection With timer Hygienic Solid State Auto Switch 1577 Direct 1579 1580 D-H7A1/H7A2/H7B 1581 D-G59/G5P/K59 1582 D-H7C 1583 D-G39/K39 1584 D-G39A/K39A 1585 D-F79/F7P/J79 1586 D-F7NV/F7PV/F7BV 1587 Connector D-J79C 1588 Grommet D-F59/F5P/J59 1589 Terminal conduit D-G39C/K39C 1590 D-M9NW/M9PW/M9BW D-M9NWV/M9PWV/M9BWV 1591 Connector Grommet Grommet D-Y7NW/Y7PW/Y7BW D-Y7NWV/Y7PWV/Y7BWV Band 1578 D-M5N/M5P/M5B Terminal conduit Tie-rod 1574 1576 D-F9G/F9H (Normally closed) D-Y59A/Y59B/Y7P D-Y7G/Y7H (Normally closed) Grommet Band 1575 D-F8N/F8P/F8B D-Y69A/Y69B /Y7PV Rail A Grommet Page Grommet Rail Grommet Tie-rod Grommet 1592 D-M5NW/M5PW/M5BW 1593 D-H7NW/H7PW/H7BW 1594 D-G59W/G5PW/K59W 1595 D-F79W/F7PW/J79W 1596 D-F7NWV/F7BWV 1597 D-F59W/F5PW/J59W 1598 D-H7NF 1599 D-G59F 1600 Band Grommet Rail Grommet D-F79F 1601 Tie-rod Grommet D-F59F 1602 Direct Grommet D-M9PA/M9NA/M9BA D-M9PAV/M9NAV/M9BAV 1603 D-Y7BA 1604 D-H7BA 1605 D-G5BA 1606 Band Grommet Rail Grommet D-F7BA D-F7BAV 1607 Tie-rod Grommet D-F5BA 1608 Direct Grommet D-F6N/F6P/F6B 1609 Band Grommet D-G5NT 1610 Rail Grommet D-F7NT 1611 Tie-rod Grommet D-F5NT 1612 Direct Grommet D-M5NT/M5PT 1613 D-P3DWSC/P3DWSE 1614 D-P3DW 1615 D-P4DWSC/P4DWSE 1616 Rail, Tie-rod, Direct Grommet Rail Grommet Sensor section: Rail Amplifier section: DIN rail Band Rail Direct D-P4DW 1617 Grommet D-F7NJ 1618 Grommet D-G5NB 1619 Grommet D-F7K/Y7K 1620 Solid State Auto Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA). Flexibility is 1.5 times greater than the conventional model (SMC comparison). Using flexible cable as standard spec. D-M9, D-M9V (With indicator light) Auto switch model D-M9N D-M9NV D-M9P D-M9PV D-M9B D-M9BV Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Wiring type 2-wire 3-wire NPN Output type Applicable load PNP — IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) — Current consumption 10 mA or less Load voltage — 28 VDC or less 40 mA or less Load current Internal voltage drop 24 VDC (10 to 28 VDC) — 2.5 to 40 mA 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less 100 µA or less at 24 VDC 0.8 mA or less Leakage current Indicator light Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-M9N Auto switch model Sheath Insulator Conductor D-M9P Outside diameter [mm] D-M9B 2.7 x 3.2 (ellipse) Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.9 Effective area [mm2] 0.15 Strand diameter [mm] ø0.05 Minimum bending radius [mm] (Reference values) 2 cores (Brown/Blue) 20 Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Caution Precautions Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. Weight (g) Auto switch model Lead wire length D-M9N(V) D-M9P(V) D-M9B(V) 0.5 m (Nil) 8 7 1 m (M) 14 13 3 m (L) 41 38 5 m (Z) 68 63 Dimensions (mm) D-M9V M2.5 x 4 L Slotted set screw Indicator light M2.5 x 4 L Indicator light Slotted set screw 8 2 3.2 2.8 2.7 2.8 20 2.7 22 Most sensitive position 2.6 6 9.5 3.2 4 4 2.6 4.6 D-M9 D- 4 6 Most sensitive position 1575 Solid State Auto Switch Direct Mounting Style D-F8N/D-F8P/D-F8B RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-F8 (With indicator light) Auto switch model D-F8N D-F8P D-F8B Electrical entry direction Perpendicular Perpendicular Perpendicular 3-wire Wiring type Caution Precautions Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. 2-wire — Output type NPN Applicable load IC circuit, 24 VDC Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less PNP — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 2.5 to 40 mA 0.8 V or less 4 V or less Internal voltage drop 100 µA or less at 24 VDC Leakage current Indicator light 0.8 mA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F8N Auto switch model Sheath Insulator Conductor D-F8P D-F8B Outside diameter [mm] ø2.7 Number of cores 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue) Outside diameter [mm] ø0.91 ø0.96 Effective area [mm2] 0.15 0.18 ø0.08 Strand diameter [mm] 17 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F8N Auto switch model D-F8P 0.5 m (Nil) 7 3 m (L) 32 5 m (Z) 52 Lead wire length Dimensions (mm) D-F8N/D-F8P/D-F8B M2.5 x 4 L Slotted set screw 4.3 2.8 10 10.9 3 ø2.7 4.6 Indicator light 2 3.1 4 1576 D-F8B 8 Most sensitive position Normally Closed Solid State Auto Switch Direct Mounting Style D-F9G/D-F9H RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-F9G, D-F9H (With indicator light) D-F9G Auto switch model D-F9H Wiring type 3-wire Output type NPN PNP Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption — Load current 40 mA or less 80 mA or less Internal voltage drop 1.5 V or less 0.8 V or less (0.8 V or less at 10 mA load current) Leakage current 100 µA or less at 24 VDC Indicator light Red LED illuminates when detecting nothing. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F9G Auto switch model Sheath Insulator Conductor D-F9H Outside diameter [mm] ø2.7 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.91 Effective area [mm2] 0.15 Strand diameter [mm] ø0.08 17 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F9G Auto switch model D-F9H 0.5 m (Nil) 7 3 m (L) 37 5 m (Z) 61 Lead wire length Dimensions (mm) M2.5 x 4 L Slotted set screw 2 SMC D-F9H 22 NC Indicator light 2.8 Precautions Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. 28 VDC or less 2.6 Caution 10 mA or less Load voltage ø2.7 Output signal turns on when no magnetic force is detected. D- 4 6 Most sensitive position 1577 Solid State Auto Switch Direct Mounting Style D-Y59 AB /D-Y69 AB /D-Y7P(V) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Using flexible cable as standard spec. PLC: Programmable Logic Controller D-Y5, D-Y6, D-Y7P, D-Y7PV (With indicator light) Auto switch model D-Y59A D-Y69A D-Y7P D-Y7PV D-Y59B D-Y69B Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular 3-wire Wiring type 2-wire NPN Output type PNP — IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less Applicable load — 24 VDC (10 to 28 VDC) 40 mA or less 80 mA or less 2.5 to 40 mA 1.5 V or less (0.8 V or less at 10 mA load current) 0.8 V or less 4 V or less Load current Internal voltage drop — 28 VDC or less Load voltage Leakage current 0.8 mA or less at 24 VDC 100 µA or less at 24 VDC Indicator light Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Flexible Heavy-duty Lead Wire Specifications D-Y9A Auto switch model Sheath Insulator D-Y7P Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.0 Conductor Effective area [mm2] 0.15 Strand diameter [mm] ø0.05 D-Y9B 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-Y7P(V) D-Y59A D-Y69A D-Y59B D-Y69B 0.5 m (Nil) 10 9 3 m (L) 53 50 5 m (Z) 87 83 Lead wire length Dimensions (mm) D-Y59A/D-Y7P/D-Y59B D-Y69A/D-Y7PV/D-Y69B M2.5 x 4 L Slotted set screw M2.5 x 4 L Slotted set screw SMC 6.2 SMC 27.3 ø3.4 5 8.5 5 29 ø3.4 6.2 Indicator light 2.5 Indicator light 2.5 12.5 1578 Most sensitive position 12.5 Most sensitive position Normally Closed Solid State Auto Switch Direct Mounting Style D-Y7G/D-Y7H RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-Y7G, D-Y7H (With indicator light) D-Y7G Auto switch model D-Y7H Wiring type 3-wire Output type NPN PNP Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less — Load current 40 mA or less 80 mA or less 1.5 V or less Internal voltage drop 0.8 V or less (0.8 V or less at 10 mA load current) Leakage current 100 µA or less at 24 VDC Indicator light Red LED illuminates when detecting nothing. Standard CE marking, RoHS Oilproof Flexible Heavy-duty Lead Wire Specifications D-Y7G Auto switch model Sheath Insulator Conductor D-Y7H Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.0 Effective area [mm2] 0.15 Strand diameter [mm] ø0.05 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-Y7G Auto switch model D-Y7H 0.5 m (Nil) 10 3 m (L) 53 5 m (Z) 87 Lead wire length Dimensions (mm) Indicator light SMC 6.2 2.5 ø3.4 M2.5 x 4 L Slotted set screw NC 29 D- 5 Output signal turns on when no magnetic force is detected. Using flexible cable as standard spec. D-Y7G 12.5 Most sensitive position 1579 Solid State Auto Switch Direct Mounting Style D-M5N/D-M5P/D-M5B RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-M5 (With indicator light) D-M5N Auto switch model D-M5P D-M5B 3-wire Wiring type Output type 2-wire NPN PNP — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less Applicable load — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop 100 µA or less at 24 VDC Leakage current Indicator light 4 V or less 0.8 V or less 0.8 mA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-M5N Auto switch model Sheath Insulator Conductor D-M5P Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-M5B 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-M5N D-M5P 16 14 3 m (L) 60 53 5 m (Z) 95 84 Lead wire length Dimensions (mm) Indicator light ø3 mounting hole Most sensitive position 1580 D-M5B 0.5 m (Nil) Solid State Auto Switch Band Mounting Style D-H7A1/D-H7A2/D-H7B RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-H7 (With indicator light) D-H7A1 Auto switch model D-H7A2 Wiring type D-H7B 3-wire Output type 2-wire NPN Applicable load PNP — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop Leakage current 0.8 V or less 100 µA or less at 24 VDC Indicator light 4 V or less 0.8 mA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-H7A1 D-H7A2 Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-H7B 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-H7A1 D-H7A2 D-H7B 0.5 m (Nil) 13 11 3 m (L) 57 50 5 m (Z) 92 81 Lead wire length Dimensions (mm) Indicator light ø3.5 mounting hole D- Most sensitive position 1581 Solid State Auto Switch Band Mounting Style D-G59/D-G5P/D-K59 RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-G5, D-K59 (With indicator light) D-G59 Auto switch model D-G5P Wiring type D-K59 3-wire Output type 2-wire NPN Applicable load PNP — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop Leakage current 100 µA or less at 24 VDC Indicator light 4 V or less 0.8 V or less 0.8 mA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-G59 D-G5P Outside diameter [mm] D-K59 ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 2 cores (Brown/Blue) 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-G59 D-G5P 20 3 m (L) 78 68 5 m (Z) 124 108 Lead wire length Dimensions 18 (mm) Indicator light ø4.5 mounting hole Most sensitive position 1582 D-K59 0.5 m (Nil) Solid State Auto Switch Band Mounting Style D-H7C RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Connector PLC: Programmable Logic Controller D-H7C (With indicator light) D-H7C Auto switch model Wiring type 2-wire Output type — Applicable load 24 VDC Relay, PLC Power supply voltage — Current consumption — Load voltage 24 VDC (10 to 28 VDC) Load current 5 to 40 mA Internal voltage drop 4 V or less Leakage current 0.8 mA or less at 24 VDC Indicator light Caution Red LED illuminates when turned ON. Standard Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. Refer to page 1653 for the details. CE marking, RoHS Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Lead wires with a connector may be shipped with switches. Weight Lead wires with a connector indication Model Lead wire length D-LC05 0.5 m D-LC30 3m D-LC50 5m D-H7C Auto switch model Part No. of Lead Wires with Connectors (Applicable only for connector type) (g) 0.5 m (Nil) 15 3 m (L) 54 5 m (Z) 85 Lead wire length Dimensions (mm) Indicator light ø3.5 mounting hole Most sensitive position D- 1583 Solid State Auto Switch Band Mounting Style D-G39/D-K39 RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Terminal conduit PLC: Programmable Logic Controller D-G39, D-K39 (With indicator light) D-G39 D-K39 Wiring type 3-wire 2-wire Output type NPN — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA of load current) 5 to 40 mA 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC Auto switch model Applicable load Internal voltage drop Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. Leakage current Indicator light 4 V or less Red LED illuminates when turned ON. Standard CE marking, RoHS Note) Refer to page 1568 for solid state auto switch common specifications. Weight (g) D-G39 Auto switch model Lead wire None D-K39 116 Dimensions (mm) Tightening gland G (PF) 1/2 (Applicable cable O.D. ø6.8 to ø9.6) Indicator light 1584 Most sensitive position Solid State Auto Switch Band Mounting Style D-G39A/D-K39A RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Terminal conduit PLC: Programmable Logic Controller D-G39A, D-K39A (With indicator light) D-G39A D-K39A Wiring type 3-wire 2-wire Output type NPN — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA of load current) 5 to 40 mA 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC Auto switch model Applicable load Internal voltage drop Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. Leakage current Indicator light 4 V or less Red LED illuminates when turned ON. Standard CE marking, RoHS Note) Refer to page 1568 for solid state auto switch common specifications. Weight (g) D-G39A Auto switch model Lead wire None D-K39A 110 Dimensions (mm) G (PF) 1/2 (Applicable cable O.D. ø6.8 to ø9.6) Tightening gland Indicator light Most sensitive position D- 1585 Solid State Auto Switch Rail Mounting Style D-F79/D-F7P/D-J79 RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-F7, D-J79 (With indicator light) D-F79 Auto switch model D-F7P Wiring type D-J79 3-wire Output type 2-wire NPN Applicable load PNP — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop 0.8 V or less 100 µA or less at 24 VDC Leakage current Indicator light 4 V or less 0.8 mA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-F79 D-F7P Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-J79 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-F79 D-F7P 13 11 3 m (L) 57 50 5 m (Z) 92 81 Lead wire length Dimensions (mm) ø3.2 mounting hole Indicator light Most sensitive position 1586 D-J79 0.5 m (Nil) Solid State Auto Switch Rail Mounting Style D-F7NV/D-F7PV/D-F7BV Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Electrical entry: Perpendicular RoHS PLC: Programmable Logic Controller D-F7V (With indicator light) D-F7NV Auto switch model D-F7PV Wiring type D-F7BV 3-wire Output type 2-wire NPN Applicable load PNP — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop 0.8 V or less 100 µA or less at 24 VDC Leakage current Indicator light 4 V or less 0.8 mA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-F7NV D-F7PV Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-F7BV 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-F7NV D-F7PV D-F7BV 0.5 m (Nil) 13 11 3 m (L) 57 50 5 m (Z) 92 81 Lead wire length Dimensions (mm) ø3.2 mounting hole Indicator light D- Most sensitive position 1587 Solid State Auto Switch Rail Mounting Style D-J79C RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Connector PLC: Programmable Logic Controller D-J79C (With indicator light) D-J79C Auto switch model 2-wire Wiring type — Output type 24 VDC Relay, PLC Applicable load — Power supply voltage — Current consumption Load voltage 24 VDC (10 to 28 VDC) Load current 5 to 40 mA 4 V or less Internal voltage drop 0.8 mA or less at 24 VDC Leakage current Red LED illuminates when turned ON. Indicator light CE marking, RoHS Standard Caution Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. Refer to page 1653 for the details. Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Lead wires with a connector may be shipped with auto switches. Weight (g) D-J79C Auto switch model Lead wires with a connector indication 0.5 m (Nil) 13 3 m (L) 52 5 m (Z) 83 Lead wire length Part No. of Lead Wires with Connectors (Applicable only for connector type) Model Lead wire length D-LC05 0.5 m D-LC30 3m D-LC50 5m Dimensions (mm) ø3.2 mounting hole Indicator light Most sensitive position 1588 Solid State Auto Switch Tie-rod Mounting Style D-F59/D-F5P/D-J59 RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-F5, D-J59 (With indicator light) D-F59 Auto switch model D-F5P D-J59 3-wire Wiring type Output type 2-wire NPN PNP — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less Applicable load — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 80 mA or less 5 to 40 mA 0.8 V or less 4 V or less 1.5 V or less Internal voltage drop (0.8 V or less at 10 mA load current) 100 µA or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Indicator light Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-F59 D-F5P Outside diameter [mm] D-J59 ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 2 cores (Brown/Blue) 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-F59 D-F5P D-J59 0.5 m (Nil) 23 3 m (L) 81 71 5 m (Z) 127 111 Lead wire length Dimensions 21 (mm) D-F59/D-F5P/D-J59 Mounting hole Indicator light D- Most sensitive position 1589 A Solid State Auto Switch Tie-rod Mounting Style D-G39C/D-K39C RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Terminal conduit PLC: Programmable Logic Controller D-G39C, D-K39C (With indicator light) D-G39C D-K39C Wiring type 3-wire 2-wire Output type NPN — Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Auto switch model Current consumption 10 mA or less — Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA of load current) 5 to 40 mA 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC Internal voltage drop Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. Current leakage Indicator light 4 V or less Red LED illuminates when turned ON. Standard CE marking, RoHS Note) Refer to page 1568 for solid state auto switch common specifications. Weight Auto switch model D-G39C-4, K39C-4 D-G39C-5, K39C-5 D-G39C-6, K39C-6 D-G39C-8, K39C-8 D-G39C-10, K39C-10 (g) Applicable bore size (mm) Weight 40 50 63 80 100 162 166 184 210 232 Dimensions (mm) 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland 4xZ Hexagon socket head cap bolt G (PF) 1/2 (Applicable cable O.D. ø6.8 to ø9.6) Indicator light Most sensitive position Dimensions Auto switch model D-G39C-4, D-K39C-4 D-G39C-5, D-K39C-5 D-G39C-6, D-K39C-6 D-G39C-8, D-K39C-8 D-G39C-10, D-K39C-10 1590 Applicable bore size (mm) 40 50 63 80 100 C HW H 44 52 64 78 92 69 57 49.5 7.5 77 58 50.5 8.5 91 60.5 52 10.5 107 64 53.5 12.5 121 67 56.5 15.5 H´ T T´ 6.5 6.5 7.5 9.5 9.5 Z M5 x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA). Flexibility is 1.5 times greater than the conventional model (SMC comparison). Using flexible cable as standard spec. The proper operating range can be determined by the color of the light. (Red → Green ← Red) D-M9W, D-M9WV (With indicator light) Auto switch model D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV Perpendicular In-line Perpendicular In-line Perpendicular In-line Electrical entry direction 3-wire Wiring type 2-wire NPN Output type PNP — IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) — Current consumption 10 mA or less Applicable load Load voltage — 28 VDC or less 40 mA or less Load current Internal voltage drop 24 VDC (10 to 28 VDC) — 2.5 to 40 mA 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less 100 µA or less at 24 VDC 0.8 mA or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Leakage current Indicator light CE marking, RoHS Standard Oilproof Flexible Heavy-duty Lead Wire Specifications D-M9NW Auto switch model Sheath Caution Insulator Precautions D-M9PW Outside diameter [mm] Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.9 Effective area [mm ] 0.15 Strand diameter [mm] ø0.05 2 Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. Conductor D-M9BW 2.7 x 3.2 (ellipse) Minimum bending radius [mm] (Reference values) 2 cores (Brown/Blue) 20 Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model Lead wire length D-M9NW(V) D-M9PW(V) D-M9BW(V) 0.5 m (Nil) 8 7 1 m (M) 14 13 3 m (L) 41 38 5 m (Z) 68 63 Dimensions (mm) D-M9W D-M9WV Indicator light M2.5 x 4 L Slotted set screw Slotted set screw 8 2 3.2 4 Indicator light 4.6 M2.5 x 4 L 2.8 2.6 2.7 2.7 22 4 9.5 6 Most sensitive position 2.6 D- 3.2 4 2.8 20 6 Most sensitive position 1591 2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-Y7W, D-Y7WV (With indicator light) The proper operating range can be determined by the color of the light. (Red → Green ← Red) Using flexible cable as standard spec. D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV Auto switch model Electrical entry direction In-line Perpendicular In-line Perpendicular In-line 3-wire Wiring type NPN Output type Perpendicular 2-wire PNP — IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less Applicable load — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 2.5 to 40 mA 0.8 V or less 4 V or less Internal voltage drop 100 µA or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Flexible Heavy-duty Lead Wire Specifications D-Y7NW Auto switch model Sheath Insulator Conductor D-Y7PW Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.0 Effective area [mm2] 0.15 Strand diameter [mm] ø0.05 D-Y7BW 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model Lead wire length D-Y7NW(V) D-Y7PW(V) 0.5 m (Nil) 11 3 m (L) 54 5 m (Z) 88 Dimensions (mm) D-Y7W D-Y7WV Indicator light SMC 2.5 6.2 SMC 6.2 M2.5 x 4 L Slotted set screw ø3.4 M2.5 x 4 L Slotted set screw Indicator light 2.5 29 27.3 5 ø3.4 8.5 Most sensitive position 5 12.5 12.5 1592 D-Y7BW(V) Most sensitive position 2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-M5NW/D-M5PW/D-M5BW Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) RoHS PLC: Programmable Logic Controller D-M5W (With indicator light) D-M5NW Auto switch model D-M5PW Wiring type D-M5BW 3-wire Output type 2-wire PNP NPN Applicable load — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop Leakage current 4 V or less 0.8 V or less 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-M5NW Auto switch model Sheath Insulator Conductor D-M5PW Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-M5BW 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-M5NW Auto switch model D-M5PW D-M5BW 0.5 m (Nil) 16 14 3 m (L) 60 53 5 m (Z) 95 84 Lead wire length Dimensions (mm) Indicator light ø3 mounting hole D- Most sensitive position 1593 2-Color Indication Type Solid State Auto Switch Band Mounting Style D-H7NW/D-H7PW/D-H7BW RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-H7W (With indicator light) D-H7NW Auto switch model D-H7PW Wiring type D-H7BW 3-wire Output type 2-wire PNP NPN Applicable load — IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop 0.8 V or less 4 V or less 100 µA or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-H7NW Auto switch model Sheath Insulator Conductor D-H7PW Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-H7BW 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-H7NW Auto switch model D-H7PW 13 11 3 m (L) 57 50 5 m (Z) 92 81 Lead wire length Dimensions (mm) 4.6 29 8 6.5 ø3.4 9 Indicator light ø3.5 mounting hole 8 11.5 4.3 10.5 1594 D-H7BW 0.5 m (Nil) Most sensitive position 2-Color Indication Type Solid State Auto Switch Band Mounting Style D-G59W/D-G5PW/D-K59W RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-G5W, D-K59W (With indicator light) D-G59W Auto switch model D-K59W D-G5PW Wiring type 2-wire 3-wire Output type NPN Applicable load Power supply voltage — PNP IC circuit, Relay, PLC 24 VDC Relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop 4 V or less 0.8 V or less Leakage current 100 µA or less at 24 VDC Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Standard 0.8 mA or less at 24 VDC CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-G59W D-G5PW Outside diameter [mm] D-K59W ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 2 cores (Brown/Blue) 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-G59W D-G5PW D-K59W 0.5 m (Nil) 20 3 m (L) 78 68 5 m (Z) 124 108 Lead wire length Dimensions 18 (mm) Indicator light ø4.5 mounting hole D- Most sensitive position 1595 2-Color Indication Type Solid State Auto Switch Rail Mounting Style D-F79W/D-F7PW/D-J79W RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-F7W, D-J79W (With indicator light) D-F79W Auto switch model D-J79W D-F7PW Wiring type 2-wire 3-wire Output type — PNP NPN Applicable load IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less — 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 80 mA or less 5 to 40 mA Internal voltage drop 4 V or less 0.8 V or less 100 µA or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F79W Auto switch model Sheath Insulator Conductor D-F7PW Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 D-J79W 2 cores (Brown/Blue) 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F79W Auto switch model D-F7PW D-J79W 0.5 m (Nil) 13 11 3 m (L) 57 50 5 m (Z) 92 81 Lead wire length Dimensions (mm) ø3.2 mounting hole 8 7 15 Indicator light 23 8.5 1596 Most sensitive position 3.2 6.2 11 ø3.4 4.6 2-Color Indication Type Solid State Auto Switch Rail Mounting Style D-F7NWV/D-F7BWV RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Electrical entry: Perpendicular The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-F7WV (With indicator light) D-F7NWV D-F7BWV Wiring type 3-wire 2-wire Output type NPN — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less — Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) 5 to 40 mA 100 µA or less at 24 VDC 0.8 mA or less at 24 VDC Auto switch model Applicable load Internal voltage drop Leakage current 4 V or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light CE marking, RoHS Standard Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-F7NWV D-F7BWV Outside diameter [mm] Number of cores ø3.4 3 cores (Brown/Blue/Black) Outside diameter [mm] 2 cores (Brown/Blue) ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F7NWV D-F7BWV 0.5 m (Nil) 13 11 3 m (L) 57 50 5 m (Z) 92 81 Auto switch model Lead wire length Dimensions (mm) ø3.2 mounting hole Indicator light D- Most sensitive position 1597 2-Color Indication Type Solid State Auto Switch Tie-rod Mounting Style D-F59W/D-F5PW/D-J59W RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-F5W, D-J59W (With indicator light) D-F59W Auto switch model D-F5PW Wiring type D-J59W 3-wire Output type 2-wire PNP NPN Applicable load — IC circuit, Relay, PLC 24 VDC Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) — Current consumption 10 mA or less Load voltage — 28 VDC or less Load current Internal voltage drop 40 mA or less 1.5 V or less (0.8 V or less at 10 mA load current) — 24 VDC (10 to 28 VDC) 80 mA or less 5 to 40 mA 4 V or less 0.8 V or less 100 µA or less at 24 VDC Leakage current 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Auto switch model Sheath Insulator Conductor D-F59W D-F5PW Outside diameter [mm] D-J59W ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 2 cores (Brown/Blue) 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model D-F59W D-F5PW 23 3 m (L) 81 71 5 m (Z) 127 111 Lead wire length Dimensions 21 (mm) Mounting hole Indicator light Most sensitive position 1598 D-J59W 0.5 m (Nil) 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Band Mounting Style D-H7NF RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-H7NF (With indicator light) Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). D-H7NF Auto switch model Wiring type 4-wire Output type NPN Diagnostic output Normal operation Applicable load IC circuit, Relay, PLC Power voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 50 mA or less at the total amount of normal output and diagnostic output Internal voltage drop 1.5 V or less (0.8 V or less at each output 5 mA) 100 µA or less at 24 VDC Current leakage Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-H7NF Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 4 cores (Brown/Blue/Black/Orange) Outside diameter [mm] ø0.98 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-H7NF Auto switch model Lead wire length 0.5 m (Nil) 13 3 m (L) 56 5 m (Z) 90 Diagnostic Output Operation The diagnostic output signal is output within the red display area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the proper operating range (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON. Indicator light OFF Red ON Green Red OFF Red OUT (Normal output) Diagnosis OUT (Diagnostic output) Dimensions (mm) ø3.4 ø3.5 mounting hole Indicator light D- Most sensitive position 1599 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Band Mounting Style D-G59F RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-G59F (With indicator light) Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). D-G59F Auto switch model Wiring type 4-wire Output type NPN Diagnostic output Normal operation Applicable load IC circuit, Relay, PLC Power voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 50 mA or less at the total amount of normal output and diagnostic output Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA) Current leakage 100 µA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light CE marking, RoHS Standard Oilproof Heavy-duty Lead Wire Specifications D-G59F Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 4 cores (Brown/Blue/Black/Orange) Outside diameter [mm] ø1.29 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-G59F Auto switch model 0.5 m (Nil) Lead wire length 20 3 m (L) 74 5 m (Z) 117 Diagnostic Output Operation The diagnostic output signal is output within the red display area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the proper operating range (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON. Dimensions Indicator light OFF Red ON Green Red Red OUT (Normal output) Diagnosis OUT (Diagnostic output) (mm) ø4 ø4.5 mounting hole Indicator light 1600 OFF Most sensitive position 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Rail Mounting Style D-F79F RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-F79F (With indicator light) Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). D-F79F Auto switch model Wiring type 4-wire Output type NPN Diagnostic output Normal operation Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 50 mA or less at the total amount of normal output and diagnostic output Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA) Leakage current 100 µA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F79F Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 4 cores (Brown/Blue/Black/Orange) Outside diameter [mm] ø0.98 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F79F Auto switch model Lead wire length 0.5 m (Nil) 13 3 m (L) 56 5 m (Z) 90 Diagnostic Output Operation The diagnostic output signal is output within the red display area (where indicator light is Red), and it is not output within the proper operating range (where indicator light is Green). When the auto switch detecting position is not adjusted, the diagnostic output becomes activated. Indicator light Red Green Red Red OUT (Normal output) Diagnosis OUT (Diagnostic output) Dimensions (mm) ø3.2 Mounting hole Indicator light ø3.4 D- Most sensitive position 1601 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Tie-rod Mounting Style D-F59F RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-F59F (With indicator light) Since the diagnostic output signal can be detected in the red display area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). D-F59F Auto switch model Wiring type 4-wire Output type NPN Diagnostic output Normal operation Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 50 mA or less at the total amount of normal output and diagnostic output Internal voltage drop 1.5 V or less (0.8 V or less at 5 mA) 100 µA or less at 28 VDC Leakage current Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F59F Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 4 cores (Brown/Blue/Black/Orange) Outside diameter [mm] ø1.29 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F59F Auto switch model 0.5 m (Nil) Lead wire length 22 3 m (L) 77 5 m (Z) 121 Diagnostic Output Operation The diagnostic output signal is output within the red display area (where indicator light is Red), and it is not output within the proper operating range (where indicator light is Green). When the auto switch detecting position is not adjusted, the diagnostic output becomes activated. Indicator light OFF Red ON Green OFF Red OUT (Normal output) Diagnosis OUT (Diagnostic output) Dimensions (mm) Mounting hole ø4 Indicator light Most sensitive position 1602 Red Water Resistant 2-Color Indication Type Solid State Auto Switch: Direct Mounting Style D-M9NA(V)/D-M9PA(V)/D-M9BA(V) RoHS Auto Switch Specifications Grommet PLC: Programmable Logic Controller Water (coolant) resistant type 2-wire load current is reduced (2.5 to 40 mA). The proper operating range can be determined by the color of the light. (Red → Green ← Red) Using flexible cable as standard spec. D-M9A, D-M9AV (With indicator light) D-M9NA D-M9NAV D-M9PA D-M9PAV D-M9BA D-M9BAV Auto switch model Electrical entry direction In-line Perpendicular In-line In-line Perpendicular 2-wire NPN Output type PNP — IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) — Current consumption 10 mA or less Applicable load Load voltage — 28 VDC or less 40 mA or less Load current Internal voltage drop 24 VDC (10 to 28 VDC) — 2.5 to 40 mA 0.8 V or less at 10 mA (2 V or less at 40 mA) 4 V or less 100 µA or less at 24 VDC 0.8 mA or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Leakage current Indicator light Standard Caution Perpendicular 3-wire Wiring type CE marking, RoHS Oilproof Flexible Heavy-duty Lead Wire Specifications Precautions D-M9NA Auto switch model Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. Please consult with SMC if using coolant liquid other than water based solution. Sheath Insulator D-M9PA Outside diameter [mm] Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.9 Effective area [mm ] 0.15 Strand diameter [mm] ø0.05 2 Conductor D-M9BA 2.7 x 3.2 (ellipse) Minimum bending radius [mm] (Reference values) 2 cores (Brown/Blue) 20 Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model Lead wire length D-M9NA(V) D-M9PA(V) D-M9BA(V) 0.5 m (Nil) 8 7 1 m (M) 14 13 3 m (L) 41 38 5 m (Z) 68 63 Dimensions (mm) D-M9AV M2.5 x 4 L Slotted set screw M2.5 x 4 L Slotted set screw 3.2 SMC 2.7 2.7 22 D- Most sensitive position 4 6 9.3 3 2.6 4 3.2 0.2 24 2.8 4 SMC 4 8 2 Indicator light 2.8 Indicator light 4.6 D-M9A 6 Most sensitive position 1603 Water Resistant 2-Color Indication Type Solid State Auto Switch: Direct Mounting Style D-Y7BA RoHS Auto Switch Specifications Grommet Water (coolant) resistant type Using flexible cable as standard spec. The proper operating range can be determined by the color of the light. (Red → Green ← Red) Refer to SMC website for the details of the products conforming to the international standards. PLC: Programmable Logic Controller D-Y7BA (With indicator light) D-Y7BA Auto switch model Wiring type 2-wire Applicable load 24 VDC Relay, PLC Load voltage 24 VDC (10 to 28 VDC) Load current 2.5 to 40 mA Internal voltage drop 4 V or less Leakage current 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Flexible Heavy-duty Lead Wire Specifications D-Y7BA Auto switch model Sheath Insulator Caution Precautions Please consult with SMC if using coolant liquid other than water based solution. Detection characteristics (operating range) are the same as D-Y5 and D-Y7W, but the detection area length is different. Conductor Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1 Effective area [mm2] 0.15 Strand diameter [mm] ø0.05 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-Y7BA Auto switch model Lead wire length 3 m (L) 54 5 m (Z) 88 Dimensions (mm) M2.5 x 4 L Slotted set screw Indicator light SMC 6.2 2.5 D−Y7BA 35 DC24V 12.5 1604 Most sensitive position 5.2 5 Production lot Water Resistant 2-Color Indication Type Solid State Auto Switch: Band Mounting Style D-H7BA RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Water (coolant) resistant type The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-H7BA (With indicator light) D-H7BA Auto switch model Wiring type 2-wire Output type — Applicable load 24 VDC Relay, PLC Power supply voltage — Current consumption — Load voltage 24 VDC (10 to 28 VDC) Load current 5 to 40 mA Internal voltage drop Leakage current Precautions Please consult with SMC if using coolant liquid other than water based solution. Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-H7BA Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-H7BA Auto switch model Lead wire length 3 m (L) 50 5 m (Z) 81 Dimensions (mm) ø3.4 Caution 4 V or less 0.8 mA or less at 24 VDC Indicator light ø3.5 mounting hole D- Most sensitive position 1605 Water Resistant 2-Color Indication Type Solid State Auto Switch: Band Mounting Style D-G5BA RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Water (coolant) resistant type The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-G5BA (With indicator light) D-G5BA Auto switch model Wiring type 2-wire Output type — Applicable load 24 VDC Relay, PLC Power supply voltage — Current consumption — Load voltage 24 VDC (10 to 28 VDC) Load current 5 to 40 mA Internal voltage drop 4 V or less Leakage current Caution Precautions Please consult with SMC if using coolant liquid other than water based solution. 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-G5BA Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-G5BA Auto switch model Lead wire length 3 m (L) 68 5 m (Z) 108 Dimensions ø4 (mm) Indicator light ø4.5 mounting hole Most sensitive position 1606 Water Resistant 2-Color Indication Type Solid State Auto Switch: Rail Mounting Style D-F7BA(V) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller Water (coolant) resistant type The proper operating range can be determined by the color of the light. (Red → Green ← Red) D-F7BA(V) (With indicator light) Auto switch model D-F7BA D-F7BAV Electrical entry direction In-line Perpendicular Wiring type 2-wire Output type — Applicable load 24 VDC Relay, PLC Power supply voltage — Current consumption — Load voltage 24 VDC (10 to 28 VDC) Load current 5 to 40 mA Internal voltage drop 4 V or less Leakage current 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard Caution Precautions CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications Please consult with SMC if using coolant liquid other than water based solution. D-F7BA Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F7BA Auto switch model Lead wire length D-F7BAV 3 m (L) 50 5 m (Z) 81 Dimensions (mm) D-F7BA D-F7BAV ø3.2 mounting hole 8 ø3.2 mounting hole Indicator light SMC 7 15 Indicator light 23 Most sensitive position 8.5 Most sensitive position 6.2 11 15 3.2 ø3.4 1607 D- Water Resistant 2-Color Indication Type Solid State Auto Switch: Tie-rod Mounting Style D-F5BA RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Water (coolant) resistant type The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-F5BA (With indicator light) D-F5BA Auto switch model Wiring type 2-wire Output type — Applicable load 24 VDC Relay, PLC Power supply voltage — Current consumption — Load voltage 24 VDC (10 to 28 VDC) Load current 5 to 40 mA Internal voltage drop 4 V or less Leakage current Caution Precautions Please consult with SMC if using coolant liquid other than water based solution. 0.8 mA or less at 24 VDC Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F5BA Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F5BA Auto switch model Lead wire length 3 m (L) 71 5 m (Z) 111 Dimensions (mm) Mounting hole ø4 Indicator light Most sensitive position 1608 For Hygienic Design Cylinders Solid State Auto Switch: Direct Mounting Style D-F6N/D-F6P/D-F6B RoHS Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA) Using flexible cable as standard spec. D-F6 (With indicator light) D-F6N Auto switch part no. D-F6P Electrical entry direction D-F6B In-line Wiring type 2-wire 3-wire NPN Output type Applicable load PNP — IC circuit, relay, and PLC 24 VDC relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 V) — Current consumption 10 mA or less Load voltage 28 VDC or less 40 mA or less Load current Internal voltage drop — 24 VDC (10 to 28 VDC) — 2.5 to 40 mA 0.8 V or less at 10 mA (2V or less at 40 mA) 4 V or less 100 µA or less at 24 V DC 0.8 mA or less Leakage current Indicator light Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Flexible Heavy-duty Lead Wire Specifications D-F6N Auto switch model Sheath D-F6P Outside diameter [mm] Insulator Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.9 Effective area [mm ] 0.15 Strand diameter [mm] ø0.05 2 Caution Conductor Precautions Minimum bending radius [mm] (Reference values) Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. D-F6B 2.7 x 3.2 (ellipse) 2 cores (Brown/Blue) 20 Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) Auto switch model Lead wire length D-F6N D-F6P D-F6B 0.5 m (Nil) 20 19 3 m (L) 53 50 5 m (Z) 80 75 Dimensions (mm) D-F6B D-F6 3.2 (22) 8.5 (24) 16 Indicator light 29 Most sensitive position 2.7 10.6 ø7 7 D-F6N/F6P 3.2 (22) D- 7 Most sensitive position 1609 Solid State Auto Switch with Timer Band Mounting Style D-G5NT RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-G5NT (With indicator light) With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-G5NT Auto switch model Wiring type 3-wire Output type NPN Output operation Off-delay Operating time 1 ms or less Off-delay time 200 ± 50 ms Applicable load Power supply voltage IC circuit, Relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop Leakage current Indicator light 1.5 V or less (0.8 V or less at 10 mA) 100 µA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-G5NT Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-G5NT Auto switch model Lead wire length 3 m (L) 78 5 m (Z) 124 Timer Operation Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning. Ex.) Cylinder speed — 1000 mm/sec. PLC response time — 0.1 sec. Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Auto switch detecting time Auto switch output ON time PLC response time Dimensions (mm) ø4 ø4.5 mounting hole Indicator light 1610 Auto switch operating range (mm) Cylinder speed (mm/s) Most sensitive position Solid State Auto Switch with Timer Rail Mounting Style D-F7NT RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-F7NT (With indicator light) D-F7NT Auto switch model Wiring type 3-wire Output type NPN Output operation Off-delay Operating time 1 ms or less Off-delay time 200 ± 50 ms Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 1.5 V or less (0.8 V or less at 10 mA) 100 µA or less at 24 VDC Leakage current Indicator light Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F7NT Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Weight (g) D-F7NT Auto switch model Lead wire length 3 m (L) 57 5 m (Z) 92 Timer Operation Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning. Ex.) Cylinder speed — 1000 mm/sec. PLC response time — 0.1 sec. Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Switch detecting time Switch operating range (mm) Cylinder speed (mm/s) Switch output ON time PLC response time Dimensions (mm) Indicator light ø3.4 ø3.2 mounting hole D- Most sensitive position 1611 Solid State Auto Switch with Timer Tie-rod Mounting Style D-F5NT RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection PLC: Programmable Logic Controller D-F5NT (With indicator light) D-F5NT Auto switch model Wiring type 3-wire Output type NPN Output operation Off-delay Operating time 1 ms or less Off-delay time 200 ± 50 ms Applicable load Power supply voltage IC circuit, Relay, PLC 5, 12, 24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop Leakage current Indicator light 1.5 V or less (0.8 V or less at 10 mA) 100 µA or less at 24 VDC Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-F5NT Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Timer Operation Weight Detection of intermediate positioning for high-speed cylinder (g) D-F5NT Auto switch model Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning. Lead wire length Ex.) Cylinder speed — 1000 mm/sec. PLC response time — 0.1 sec. Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Dimensions 3 m (L) 81 5 m (Z) 127 (mm) Mounting hole Switch operating range (mm) Cylinder speed (mm/s) Indicator light ø4 Switch detecting time Switch output ON time PLC response time Most sensitive position 1612 Solid State Auto Switch with Timer Direct Mounting Style D-M5NT/D-M5PT RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection PLC: Programmable Logic Controller D-M5T (With indicator light) D-M5PT D-M5NT Auto switch model Wiring type 3-wire Output type NPN PNP Output operation Off-delay Operating time 1 ms or less Off-delay time 200 ± 50 ms Applicable load IC circuit, Relay, PLC Power supply voltage 5, 12, 24 VDC (4.5 to 28 VDC) 10 mA or less Current consumption 12 mA or less 28 VDC or less Load voltage — 80 mA or less Load current 2 V or less Internal voltage drop 0.8 V or less (0.8 V or less at 10 mA load current) Leakage current 100 µA or less at 24 VDC Indicator light Red LED illuminates when turned ON. Standard CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications D-M5NT Auto switch model Sheath Insulator Conductor D-M5PT Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Timer Operation Weight Lead wire length Ex.) Cylinder speed — 1000 mm/sec. PLC response time — 0.1 sec. Detecting point dispersion — Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Dimensions Auto switch detecting time D-M5NT Auto switch model Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning. D-M5PT 3 m (L) 60 5 m (Z) 95 (mm) Indicator light ø3.4 Detection of intermediate positioning for high-speed cylinder (g) Auto switch operating range (mm) Cylinder speed (mm/s) Auto switch output ON time PLC response time ø3 mounting hole D- Most sensitive position 1613 Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch ® D-P3DWSC/D-P3DWSE (Electrical Entry: Pre-wired connector) It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The proper operating range can be determined by the color of the light. (Red → Green ← Red) RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications PLC: Programmable Logic Controller D-P3DWSC/E (With indicator light) D-P3DWSC Auto switch model D-P3DWSE 24 VDC relay, PLC Applicable load Load voltage 24 VDC Load current 6 to 40 mA or less 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current Operating time 40 ms or less Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. CE marking, UL (CSA), RoHS Standard Oilproof Heavy-duty Lead Wire Specifications D-P3DWSC Auto switch model Sheath Insulator Precautions Conductor For single-phase AC welding machines If it is used for current inverter welders (including rectifying type) and condenser type welders, the magnetic field resistance is reduced. Please contact SMC regarding the performance. ø4.8 Number of cores 2 cores Outside diameter [mm] ø1.52 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 29 Minimum bending radius [mm] (Reference values) Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2 Insulation resistance — 50 MΩ or more (500 VDC measured via megohmmeter) (between lead wire and case) Withstand voltage — 1000 VAC for 1 minute (between lead wire and case) Ambient temperature — –10 to 60°C Enclosure — IEC60529 standard IP67 Polarity: Non-polar Magnetic Field Resistance Dimensions If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm. Please contact SMC when the AC welding current exceeds 16000 A. Body (mm) Indicator light Connector size M12 6 ø14 ø4.8 Caution D-P3DWSE Outside diameter [mm] 300 42.5 1 29 Applicable to 300 mm pre-wired connector Weight Most sensitive 10.5 position D-P3DWSC D-P3DWSE Auto switch model Lead wire length (m) 11 (g) 0.3 Heat shrink tube Note) 23 2 1 3 4 Auto switch mounting bracket (For round groove mounting: BQ6-032S) 4.7 Note) A white color heat shrink tube is attached to the D-P3DWSE type only. Auto switch mounting bracket (For square groove mounting: BMG6-025S) 4.7 (29) (29) Connector pin 3 — — OUT( ) OUT(±) — — OUT( ) D-P3DWSE OUT(±) 1614 4 33.7 2 4 ± D-P3DWSC 4 Connector pin/Wiring 1 ± Model (15.2) Most sensitive position 6.2 33.7 (15.2) Most sensitive position ∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed. In that case, please order it separately. Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P3DW (Electrical Entry: Grommet) It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The proper operating range can be determined by the color of the light. (Red → Green ← Red) ® RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications PLC: Programmable Logic Controller D-P3DW (With indicator light) D-P3DW Auto switch model 24 VDC relay, PLC Applicable load Load voltage 24 VDC Load current 6 to 40 mA or less 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current Operating time 40 ms or less Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. CE marking, UL (CSA), RoHS Standard Oilproof Heavy-duty Lead Wire Specifications D-P3DW Auto switch model Sheath Insulator Conductor Caution Outside diameter [mm] ø4.8 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.52 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 29 Minimum bending radius [mm] (Reference values) Dimensions (mm) Body Indicator light 29 500, (3000, 5000) Weight 11 1 If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm. Please contact SMC when the AC welding current exceeds 16000 A. ø4.8 Magnetic Field Resistance Impact resistance — Switch: 1000 m/s2 Insulation resistance — 50 MΩ or more (500 VDC measured via megohmmeter) (between lead wire and case) Withstand voltage — 1000 VAC for 1 minute (between lead wire and case) Ambient temperature — –10 to 60°C Enclosure — IEC60529 standard IP67 Polarity: Non-polar 6 Precautions For single-phase AC welding machines If it is used for current inverter welders (including rectifying type) and condenser type welders, the magnetic field resistance is reduced. Please contact SMC regarding the performance. (g) Most sensitive 10.5 position Lead wire length D-P3DW 0.5 m (Nil) 20 3 m (L) 102 5 m (Z) 168 Auto switch mounting bracket (For round groove mounting: BQ6-032S) 4.7 Auto switch mounting bracket (For square groove mounting: BMG6-025S) 4.7 (29) 4 (29) D- 4 Auto switch model 33.7 (15.2) Most sensitive position 6.2 33.7 (15.2) Most sensitive position ∗ When the auto switch is ordered on its own, the auto switch mounting bracket is not enclosed. In that case, please order it separately. 1615 Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P3DWASC/D-P3DWASE (Electrical Entry: Pre-wired connector) It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The proper operating range can be determined by the color of the light. (Red → Green ← Red) ® Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications PLC: Programmable Logic Controller D-P3DWASC/E (With indicator light) D-P3DWASC Auto switch model D-P3DWASE 24 VDC relay, PLC Applicable load Load voltage 24 VDC Load current 6 to 40 mA 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current Operating time 40 ms or less Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. CE marking, UL (CSA), RoHS Standard Oilproof Heavy-duty Cord Specifications D-P3DWASC Auto switch models Sheath Insulator Caution Precautions For single-phase AC welding machines If it is used for current inverter welders (including rectifying type) and condenser type welders, the magnetic field resistance is reduced. Please contact SMC regarding the performance. Conductor D-P3DWASE Outside diameter [mm] ø4.8 Number of cores 2 cores Outside diameter [mm] ø1.52 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 29 Minimum bending radius [mm] (Reference values) Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2 Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case) Withstand voltage — 1000 VAC for 1 minute (between lead wire and case) Ambient temperature — –10 to 60°C Enclosure — IEC60529 standard IP67 Polarity: Non-polar Magnetic Field Resistance Dimensions Switch mounting thread M2.5 x 12L SUS Connector size M12 (g) ø14 Indicator light D-P3DWA 3 ø4.8 Weight (mm) Body 6 If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm. Please contact SMC when the AC welding current exceeds 16000 A. 29 300 For pre-wired connector (300 mm) 42.5 11 10.5 Most sensitive position 3.95 Heat shrink tube Note) 3.3 25 Lead wire length (m) 0.3 14.3 1 Auto switch model D-P3DWASC D-P3DWASE Note) A white color heat shrink tube is attached to the D-P3DWASE type only. 2 1 3 4 Connector pin 2 — — D-P3DWASE OUT(±) B 1317-3 — 3 4 OUT( ) OUT(±) ± D-P3DWASC Connector pin and wiring 1 — OUT( ) ± Model Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P3DWA (Electrical Entry: Grommet) It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The proper operating range can be determined by the color of the light. (Red → Green ← Red) ® Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications PLC: Programmable Logic Controller D-P3DWA (With indicator light) D-P3DWA Auto switch model 24 VDC relay, PLC Applicable load Load voltage 24 VDC Load current 6 to 40 mA 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current Operating time 40 ms or less Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. CE marking, UL (CSA), RoHS Standard Oilproof Heavy-duty Cord Specifications D-P3DWA Auto switch models Sheath Insulator Precautions For single-phase AC welding machines If it is used for current inverter welders (including rectifying type) and condenser type welders, the magnetic field resistance is reduced. Please contact SMC regarding the performance. Conductor ø4.8 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.52 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 Magnetic Field Resistance Dimensions If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder/actuator or auto switch is 0 mm. Please contact SMC when the AC welding current exceeds 16000 A. Body (mm) Switch mounting thread M2.5 x 12L SUS Indicator light 6 D-P3DWA 3 Weight 29 Minimum bending radius [mm] (Reference values) Impact resistance — Switch: 1000 m/s2 Insulation resistance — 50 MΩ or more at 500 VDC Mega (between lead wire and case) Withstand voltage — 1000 VAC for 1 minute (between lead wire and case) Ambient temperature — –10 to 60°C Enclosure — IEC60529 standard IP67 Polarity: Non-polar 29 500 (3000) (5000) 1 (g) ø4.8 Caution Outside diameter [mm] 104 5 m (Z) 170 14.3 22 3 m (L) 10.5 Most sensitive position 3.95 3.3 Lead wire length D-P3DWA 0.5 m (Nil) 11 Auto switch model 1317-4 B Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P4DWSC/D-P4DWSE (Electrical Entry: Pre-wired connector) Auto Switch Specifications Grommet RoHS Refer to SMC website for the details of the products conforming to the international standards. PLC: Programmable Logic Controller It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The proper operating range can be determined by the color of the light. (Red → Green ← Red) D-P4DWS (With indicator light) D-P4DWSC Auto switch model D-P4DWSE 24 VDC relay, PLC Applicable load Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA or less 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current Operating time 40 ms or less Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. CE marking, RoHS Standard Oilproof Heavy-duty Lead Wire Specifications D-P4DWSC Auto switch model Sheath Insulator Conductor ø6 Number of cores 2 cores Outside diameter [mm] ø2.3 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 48 Minimum bending radius [mm] (Reference values) Caution Precautions For single-phase AC welding machines. Not applicable for DC inverter welding machines (including rectifying type) and or condenser type welding. 2 1 3 4 D-P4DWSE Outside diameter [mm] Impact resistance — Switch: 1000 m/s2, Connector: 300 m/s2 Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Magnetic Field Resistance If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm. Please contact SMC when the AC welding current exceeds 16000 A. Weight (g) Connector pin D-P4DWSC Auto switch model 1 2 3 4 — — OUT( ) OUT(±) — — OUT( ) ± D-P4DWSE OUT(±) Dimensions (mm) ± Model D-P4DWSC D-P4DWSE 35 Connector pin/Wiring Indicator light ø14 SMC 8.8 9.2 ø6 Connector size M12 D-P4DW (24 VDC) 32 6 4 300 20 6 1 2 x ø3.5 mounting hole 13 Most sensitive position Note) Only for D-P4DWSE Printed contents: SE 1-4 1616 Heat shrink tube Note) 44 Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P4DW RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-P4DW (With indicator light) D-P4DW Auto switch model 24 VDC relay, PLC Applicable load Load voltage 24 VDC (20 to 28 VDC) Load current 6 to 40 mA or less 5 V or less Internal voltage drop 1 mA or less at 24 VDC Leakage current Operating time 40 ms or less Indicator light Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. CE marking, RoHS Standard Oilproof Heavy-duty Lead Wire Specifications D-P4DW Auto switch model Sheath Insulator Outside diameter [mm] ø1.92 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 36 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Magnetic Field Resistance If the current of the AC welding machine is 16000 A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm. Please contact SMC when the AC welding current exceeds 16000 A. Weight (g) D-P4DW Auto switch model Lead wire length 3 m ( L) 150 5 m (Z) 244 Dimensions (mm) SMC 8.8 9.2 ø6 Indicator light D-P4DW (24 VDC) 32 6 4 2 x ø3.5 mounting hole 1 For single-phase AC welding machines. Not applicable for DC inverter welding machines (including rectifying type) and or condenser type welding. 2 cores (Brown/Blue) D- 6 Precautions Conductor ø6 Number of cores 20 Caution Outside diameter [mm] 13 Most sensitive position 1617 Heat Resistant 2-Color Indication Type Solid State Auto Switch: Rail Mounting Style D-F7NJ RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Improved heat resistant type The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-F7NJ (With indicator light) D-F7NJ Auto switch model Wiring type 3-wire Output type NPN Applicable load Relay, PLC Power supply voltage 24 VDC (20 to 26 VDC) Current consumption 25 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less 100 µA at 24 VDC Leakage current Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Caution Precautions Auto switch which can be mounted on heat resistant, compact cylinder, CDQ2-XB14. For using for other cylinders, please confirm SMC. D-F7NJ is not applicable for the heat resistant type (-XB6) since a magnet is not built in it. Ambient temperature Sensor section: 0 to 150°C Amplifier section: 0 to 60°C Impact resistance Sensor section: 1000 m/s2 Amplifier section: 300 m/s2 CE marking, RoHS Standard Oilproof Heavy-duty Lead Wire Specifications (Grommet) D-F7NJ Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 21 Minimum bending radius [mm] (Reference values) Weight (g) D-F7NJ Auto switch model Lead wire length 3 m (L) 170 5 m (Z) 210 Dimensions (mm) Indicator light (4) (64.5) 0.7 7 15 MODE POSITION HEAT PROOF AUTO SWITCH AMPLIFIRE 21.6 SMC 22 3.8 8 3000 (5000) 3 11 Most sensitive position 3000 1618 6.2 ø3.4 MADE IN JAPAN Ambient temp. of detecting circuit (amplifire) is 0~60°C. Don't install heated atmosphere. It might cause mal function and lead to cause breakage. CAUTION Load MAX. 40mA BLUE GND BLACK OUT Switch BROWN Vcc D-F7NJ BROWN(+) 24VDC BLACK(OUT) NPN 24V40mA BLUE (-) GND 40 ø3.4 Heat resistant heavy-duty cord 8.5 Wide Range Detection Type Solid State Auto Switch: Band Mounting Style D-G5NB RoHS Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller Wide range detection type Easy intermediate detection D-G5NB (With indicator light) D-G5NB Auto switch model Wiring type 3-wire Output type NPN Applicable load Relay, PLC Power supply voltage 12, 24 VDC (10 to 28 VDC) Current consumption 12 mA or less Load voltage 10 to 28 VDC or less Load current 40 mA or less Internal voltage drop 0.4 V or less 100 µA at 24 VDC Leakage current Indicator light Caution Red LED illuminates when turned ON. Standard Precautions CE marking, RoHS Oilproof Heavy-duty Lead Wire Specifications The operating range is common for all cylinder series, but it may vary depending on bore sizes. D-G5NB Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Minimum bending radius [mm] (Reference values) Note 1) Refer to page 1568 for solid state auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. 125 Bore size (mm) 20, 25, 32, 40 20, 25, 32, 40, 50, 63, 80, 100 40, 50, 63, 80, 100 20, 25, 32, 40, 50 Operating Range Bore size (mm) Cylinder series Mountable models 20 25 32 40 50 63 80 100 35 40 40 45 45 45 45 50 Note) The operating range above indicates average values at room temperature including hysteresis (assuming approximately ±30% dispersion). ∗ Refer to page 500 for CDA2-Z, page 557 for CDA2 and CDBA2. Dimensions (mm) D-G5NB 33 11.2 ø4 5 m (Z) Cylinder series CDM2-Z, CDM2, CDBM2, CDVM3, CDVM5, CDLM2, CDLG1, MLGC CDG1-Z, CDG1 CDA2-Z, CDA2, CDBA2, CDV3, CDVS1, CDL1 MGC, MGG SMC 79 14 Lead wire length D-G5NB 3 m (L) 12 Auto switch model Applicable Cylinders Indicator light ø4.5 mounting hole 6.5 D- 14.3 (g) 9.5 Weight (16) Most sensitive position 1619 Made to Order Specifications: Solid State Auto Switch Refer to SMC website for the details of the products conforming to the international standards. 1 With Pre-wired Connector • Eliminates the harnessing work by cable with connector specifications • Adopts global standardized connector (IEC947-5-2) • IP67 construction How to Order Connector Specifications D M9N S A PC Connector model M8-3 pin 1 Solid state auto switch Standard part no. 1 M12-4 pin 2 2 1 3 4 Pin arrangement ∗ For the applicable auto switch model, refer to the table below. 0.5 m 1.0 m 3.0 m Note) L is available for the D-P4DW type only. 4 3 3 Cable length S M L M8-4 pin 4 Connector model A B D M8-3 pin M8-4 pin M12-4 pin Note) Type D is available for the D-P4DW type only. Applicable Auto Switch Mounting Function Electrical entry Applicable model F79, F7P, J79 F7NV, F7PV, F7BV Grommet (In-line) F79W, F7PW, J79W 2-color Grommet indication (Perpendicular) F7NWV, F7BWV Rail mounting With diagnostic output F79F Grommet (In-line) style F7BA Water resistant Grommet F7BAV (Perpendicular) With timer F7NT Magnetic field resistant P4DW H7A1, H7A2, H7B — G59, G5P, K59 H7NW, H7PW, H7BW 2-color Band indication G59W, G5PW, K59W mounting Diagnostic output Grommet (In-line) H7NF, G59F style Water resistant H7BA, G5BA With timer G5NT Wide detection G5NB — F59, F5P, J59 F59W, F5PW, J59W Tie-rod 2-color indication mounting Diagnostic output F59F style Water resistant F5BA With timer F5NT — 1626 Grommet (In-line) Grommet (Perpendicular) Lead wire length (m) Lead wire length (m) Electrical entry Applicable model — Grommet (In-line) Y59A, Y7P, Y59B — Grommet (Perpendicular) Y69A, Y7PV, Y69B — Grommet (In-line) M9N, M9P, M9B — M9NV, M9PV, M9BV — F8N, F8P, F8B — F6N, F6P, F6B — Y7G, Y7H — F9G, F9H — Y7NW, Y7PW, Y7BW — Y7NWV, Y7PWV, Y7BWV — 0.5 1.0 3.0 Mounting Function — — — — Grommet (Perpendicular) — Grommet (In-line) — — — — — — — — — — — — — — — — Direct mounting style Normally closed Grommet (In-line) Grommet (In-line) 2-color indication Water resistant Grommet (Perpendicular) Grommet (In-line) M9NW, M9PW, M9BW — Grommet (Perpendicular) M9NWV, M9PWV, M9BWV — Y7BA — M9NA, M9PA, M9BA — M9NAV, M9PAV, M9BAV — S791/2, S7P1/2, T791/2 — S991/2, S9P1/2, T991/2 — S99V1/2, T99V1/2 — Grommet (In-line) Grommet (Perpendicular) Rotary actuator — 0.5 1.0 3.0 Grommet (In-line) Grommet (Perpendicular) With Pre-wired Connector Connector Pin Arrangement DC 2-wire type Color distinction of lead wire Meaning of contact number 1 pin 2 pin 3 pin 4 pin 1 pin 2 pin 3 pin 4 pin Brown — — Blue OUT (+) — — OUT (–) — OUT (±) OUT ( ) DC (–) OUT DC (–) OUT — — Brown Blue — DC 3-wire type Brown — Blue Black DC (+) DC 4-wire type Brown Orange Blue Black DC 2-wire, Non-polar type — Diagnostic DC (+) output ± Sensor type Connector Specifications M8-3 pin Connector model M8-3 pin 1 M8-4 pin M12-4 pin 2 1 4 2 1 3 4 Pin arrangement Conformed standard 4 3 3 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300 m/s2 Impact resistance IP67 (IEC60529 standard) Enclosure Insulation resistance 100 MΩ or more at 500 VDC measured via megohmmeter Withstand voltage 1500 VAC 1 minute (between contacts), Leak current 1 mA or less M8-4 pin Dimensions M8-3 pin 4 pin ø10 Connector model Sensor section M12-4 pin ø14 31.4 Sensor section M12-4 pin 44 Connection (Female side) Connector Cable Weight for Connector Type Part no. Connector type Weight D-APC M8-3 pin 4g D-BPC M8-4 pin 4g D-DPC M12-4 pin About 11 g As the parts are not supplied from SMC, refer to the application examples listed in the below. (For detail such as catalog availability, etc., please contact each manufacturer.) Connector size Number of pins 3 Applicable series example SAC-3P Corrence Corporation M8 4 M12 Manufacturer Phoenix Contact M8-3D M8-4D OMROM Corporation XS3 Phoenix Contact SAC-4P Corrence Corporation VA-4D OMROM Corporation XS2 Azbil Corp. PA5-4I Hirose Electric Co., Ltd. HR24 DDK Ltd. CM01-8DP4S D- 1627 Made to Order Specifications: Solid State Auto Switch -50: Without Indicator Light (Dark room) Specifications -61: Oilproof Flexible Heavy-duty Cord Specifications Symbol 2 -50 Without Indicator Light (for dark room specifications) Possible to use under the environment which hates a light. D Solid state auto switch model Applicable part no.: General purpose type, solid state auto switch except D-J51 Note) Please consult with SMC for water resistant type, timer equipped type, diagnostic output type, wide range detection type, magnetic field resistant type, heat resistant type. 50 Without indicator light (for dark room specifications) Lead wire length For lead wire length, refer to page 1568. Dimensions and specifications are common as standard products with the exception of no indicator light. Symbol 3 -61 Oilproof Flexible Heavy-duty Cord Specifications This is the product which uses a heavy-duty cord having flexible characteristics 5 times (SMC comparison) as strong as oilproof heavy-duty cord used in the standard products. D 61 Solid state auto switch part no. Applicable part no: All the solid state auto switches with the exceptance of D-J51, diagnostic output type, terminal conduit type, connector type, magnetic field resistant type, heat resistant type Oilproof flexible heavy-duty cord specifications Lead wire length For lead wire length, refer to page 1568. Note) Oilproof flexible heavyduty cord is used for the D-M9 and D-Y7 series (Except D-Y7K) as standard. No need to suffix -61 to the end of part number. Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8 type············ ø2.7, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) For other model nos.··················· ø3.4, 0.15 mm2, 3 cores (Brown, Blue, Black), 2 cores (Brown, Blue) Dimensions are identical with D-F5 type, G5 type, J59 type, K59 type. Lead wire diameter is changed from ø4 to ø3.4. In other series products, it is common as standard product's specifications. A 1628 Reed Auto Switches General Purpose Type, 2-Color Indication Type Reed Switch Variations Type Function Auto switch mounting style Electrical entry Direct Grommet 1630 D-C73/C76/C80 1631 D-B53/B54/B64 1632 D-C73C/C80C 1633 D-A33/A34 1634 D-A33A/A34A 1635 D-A44 1634 D-A44A 1635 D-A72/A73/A80 1636 D-A72H/A73H/A76H/A80H 1637 Connector D-A73C/A80C 1638 Grommet D-A53/A54/A56/A64/A67 1639 General purpose Terminal conduit DIN terminal Grommet Rail Terminal conduit D-A44C 1640 D-Z73/Z76/Z80∗∗ 1641 D-E73A/E76A/E80A 1642 Grommet Band Grommet D-B59W 1643 Rail Grommet D-A79W 1644 Tie-rod Grommet D-A59W 1645 Rod Grommet D-P79WSE 1646 D-P74 1647 Band D-B30/31/35 D-B30J/31J/35J 1649 2-color indication Direct Magnetic field resistance DIN terminal D-A33C/A34C Heat resistant Reed Auto Switch Connector Tie-rod Page D-A90/A93/A96∗ D-A90V/A93V/A96V∗ Grommet Band Auto switch model Terminal conduit Grommet ∗ Auto switches with an asterisk (∗) can be mounted on a band (excluding D-A9V), rail, tie-rod or square groove with an auto switch mounting bracket. Refer to pages 1654, 1658, 1662, 1668 and 1669 for details. ∗∗ This auto switch can be mounted by tie-rod with using auto switch mounting bracket. For details, refer to page 1665. D- 1629 Reed Auto Switch Direct Mounting Style D-A90(V)/D-A93(V)/D-A96(V) Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-A90, D-A90V (Without indicator light) D-A90, D-A90V Auto switch model Applicable load Load voltage Maximum load current Circuit diagram∗ D-A93 IC circuit, Relay, PLC 24 V or less 48 V AC 100 V AC DC or less DC or less 50 mA 40 mA 20 mA r None 1 Ω or less (Including lead wire length of 3 m) CE marking AC DC Contact protection circuit Internal resistance Standard D-A90 (V) D-A93V D-A96 (V) D-A93, D-A93V, D-A96, D-A96V (With indicator light) Auto switch model Applicable load Load voltage Caution Precautions Load current range and Maximum load current (3) Circuit diagram∗ Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. Contact protection circuit Internal voltage drop Indicator light Standard D-A93, D-A93V D-A96, D-A96V Relay, PLC 100 VAC IC circuit 4 to 8 VDC 5 to 20 mA 20 mA 24 VDC(4) 5 to 40 mA t None D-A93: 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) 0.8 V or less D-A93V: 2.7 V or less Red LED illuminates when turned ON. CE marking e Oilproof Heavy-duty Lead Wire Specifications D-A90(V) Auto switch model Outside diameter [mm] Sheath Number of cores Insulator Outside diameter [mm] Effective area [mm2] Conductor Strand diameter [mm] Lead wire minimum bending radius [mm] (Reference values) D-A93(V) D-A96(V) ø2.7 2 cores (Brown/Blue) ø0.96 0.18 ø0.08 17 3 cores (Brown/Blue/Black) ø0.91 0.15 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Model 0.5 m (Nil) 1 m (M) Lead wire length 3 m (L) 5 m (Z) D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V 6 — 30 — 6 — 30 — 6 11 30 47 6 — 30 47 8 — 41 — 8 — 41 — Dimensions (mm) D-A90V/D-A93V/D-A96V 2 ø2.7 2.8 4.5 D-A90/D-A93/D-A96 4 M2.5 x 4 L Slotted set screw 24.5 (22) M2.5 x 4 L Slotted set screw 22 2 6 Indicator light D-A90 without indicator light ( ): dimensions for D-A96. 4.5 Indicator light D-A90V without indicator light 5.1 10 9.1 ø2.7 Most sensitive position 4 10 A 1630 Most sensitive position Reed Auto Switch Band Mounting Style D-C73/D-C76/D-C80 Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-C7 (With indicator light) Auto switch model Applicable load Load voltage Max. load current and range (3) Circuit diagram∗ D-C73 D-C76 Relay, PLC IC circuit 4 to 8 VDC 20 mA t (4) 100 VAC 5 to 20 mA 24 VDC 5 to 40 mA e None 0.8 V or less 2.4 V or less Red LED illuminates when turned ON. CE marking Contact protection circuit Internal voltage drop Indicator light Standard D-C8 (Without indicator light) D-C80 Auto switch model Applicable load Load voltage Max. load current Circuit diagram∗ Relay, PLC, IC circuit AC AC 24 V or less 48 V DC 100 V DC 50 mA 40 mA 20 mA r None 1 Ω or less (Including lead wire length of 3 m) CE marking AC DC Contact protection circuit Internal resistance Standard Oilproof Heavy-duty Lead Wire Specifications Auto switch model D-C73 D-C76 D-C80 Sheath Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue) Insulator Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Conductor Strand diameter [mm] ø0.08 Lead wire minimum bending radius [mm] (Reference values) 21 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) D-C73 9 46 76 Auto switch model 0.5 m (Nil) Lead wire length 3 m (L) 5 m (Z) D-C76 10 50 — Dimensions D-C80 9 46 — (mm) 8 6.5 SMC Indicator light D-C80 without indicator light 4.3 D- 8 11.5 2 ø3.4 26 9 ø3.5 9.5 Most sensitive position 1631 Reed Auto Switch Band Mounting Style D-B53/D-B54/D-B64 Auto Switch Specifications Grommet Refer to SMC website for the details of the products conforming to the international standards. PLC: Programmable Logic Controller D-B5 (With indicator light) D-B53 Auto switch model Applicable load Load voltage Load current range (3) Circuit diagram∗ Contact protection circuit Internal voltage drop Indicator light Standard D-B54 PLC 24 VDC(4) 5 to 50 mA e None 2.4 V or less Relay, PLC 100 VAC 200 VAC 24 VDC 5 to 50 mA 5 to 25 mA 5 to 12.5 mA q Built-in 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Red LED illuminates when turned ON. CE marking (4) D-B6 (Without indicator light) D-B64 Auto switch model Applicable load Load voltage Max. load current Circuit diagram∗ 24 V or less Max. 50 mA AC DC Contact protection circuit Internal resistance Standard Relay, PLC 100 VAC Max. 25 mA w Built-in 25 Ω or less CE marking 200 VAC Max. 12.5 mA Oilproof Heavy-duty Lead Wire Specifications D-B53/B54/B64 Auto switch model Sheath Outside diameter [mm] Number of cores Insulator Outside diameter [mm] Effective area [mm2] Conductor Strand diameter [mm] Lead wire minimum bending radius [mm] (Reference values) ø4 2 cores (Brown/Blue) ø1.22 0.3 ø0.08 24 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model 0.5 m (Nil) Lead wire length 3 m (L) 5 m (Z) D-B53 D-B54 D-B64 22 78 126 22 78 126 22 78 — Dimensions (mm) 33 SMC 12 15 ø4 13 Indicator light D-B64 without indicator light 6.5 14.3 9.5 6.5 ø4.5 1632 15.5 Most sensitive position Reed Auto Switch Band Mounting Style D-C73C/D-C80C Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Connector PLC: Programmable Logic Controller D-C73C (With indicator light) D-C73C Auto switch model Applicable load Relay, PLC Load voltage 24 VDC (5) Load current range (4) Circuit diagram∗ 5 to 40 mA e Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED illuminates when turned ON. Standard CE marking D-C80C (Without indicator light) Caution D-C80C Auto switch model Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. For details, refer to page 1653. Applicable load Relay, PLC Load voltage 24 V AC DC or less Maximum load current Circuit diagram∗ 50 mA Contact protection circuit None Internal resistance r 1 Ω or less (Including lead wire length of 3 m) Standard CE marking ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Lead wire with connector may be shipped with switch. Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 5) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model D-C73C D-C80C 0.5 m (Nil) 14 14 3 m (L) 53 53 5 m (Z) 83 83 Lead wire length Lead wires with a connector indication Part No. of Lead Wires with Connectors (Applicable only for connector type) Model Lead wire length D-LC05 0.5 m D-LC30 3m D-LC50 5m Dimensions (mm) Lead wire with connector Indicator light D-C80C without indicator light D- Most sensitive position 1633 Reed Auto Switch Band Mounting Style D-A33/D-A34/D-A44 Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Terminal conduit: D-A3 DIN terminal: D-A4 PLC: Programmable Logic Controller D-A3 (With indicator light) Terminal conduit Auto switch model D-A33 D-A34 PLC Relay, PLC Applicable load Load voltage 24 VDC (3) 24 VDC (3) 100 VAC 200 VAC Load current range (2) Circuit diagram∗ 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA e q Contact protection circuit None Built-in Internal voltage drop 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) 2.4 V or less Indicator light Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. Red LED illuminates when turned ON. Standard CE marking D-A44 (With indicator light) DIN terminal D-A44 Auto switch model Applicable load Relay, PLC Load voltage 24 VDC (3) 100 VAC 200 VAC Load current range Circuit diagram∗ 5 to 50 mA 5 to 25 mA 5 to 12.5 mA q Contact protection circuit Built-in Internal voltage drop 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Indicator light Red LED illuminates when turned ON. Standard CE marking ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 3) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model Lead wire None D-A33 D-A34 D-A44 116 116 114 Dimensions (mm) D-A3 D-A44 Tightening gland 46 34 27.5 Tightening gland G 1/2 Applicable cable O.D. ø6.8 to ø11.5 Indicator light 1634 Most sensitive position 6.5 25.7 58.7 G 1/2 Applicable cable O.D. ø6.8 to ø9.6 16 Most sensitive position 36 3 49.5 Reed Auto Switch Band Mounting Style D-A33A/D-A34A/D-A44A Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Terminal conduit: D-A3 A DIN terminal: D-A44A PLC: Programmable Logic Controller D-A3A (With indicator light) Terminal conduit Auto switch model Applicable load D-A34A PLC Relay, PLC Load voltage 24 VDC (3) 24 VDC (3) 100 VAC 200 VAC Load current range (2) Circuit diagram∗ 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA Contact protection circuit Internal voltage drop Caution D-A33A e q None Built-in 2.4 V or less Indicator light Precautions 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Red LED illuminates when turned ON. Standard CE marking D-A44A (With indicator light) DIN terminal 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-A44A Auto switch part model Applicable load Relay, PLC Load voltage 24 VDC (3) 100 VAC 200 VAC Load current range Circuit diagram∗ 5 to 50 mA 5 to 25 mA 5 to 12.5 mA q Contact protection circuit Internal voltage drop Built-in 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Indicator light Standard Red LED illuminates when turned ON. CE marking ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 3) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model Lead wire D-A33A D-A34A D-A44A 112 112 110 None Dimensions (mm) D-A3A D-A44 G 1/2 (Applicable cable O.D. ø6.8 to ø9.6) 56 34 27.5 Tightening gland Tightening gland Most sensitive position 6.5 25.7 58.7 G 1/2 (Applicable cable O.D. ø6.8 to ø11.5) D- 16 Most sensitive position 36 3 49.5 1635 Reed Auto Switch Rail Mounting Style D-A72/D-A73/D-A80 Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet Electrical entry: Perpendicular PLC: Programmable Logic Controller D-A7 (With indicator light) D-A72 Auto switch model Applicable load Load voltage Load current range (3) Circuit diagram∗ D-A73 Relay, PLC 200 VAC 5 to 10 mA Relay, PLC (4) 24 VDC 100 VAC 5 to 40 mA 5 to 20 mA e None 2.4 V or less Red LED illuminates when turned ON. CE marking Contact protection circuit Internal voltage drop Indicator light Standard D-A8 (Without indicator light) D-A80 Auto switch model Applicable load Load voltage Maximum load current Circuit diagram∗ Relay, IC circuit, PLC AC AC 100 V DC 24 or less 48 V DC 40 mA 50 mA 20 mA r None 1 Ω or less (Including lead wire length of 3 m) CE marking AC V DC Contact protection circuit Internal resistance Standard Oilproof Heavy-duty Lead Wire Specifications Auto switch model D-A72 D-A73 D-A80 Sheath Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) Insulator Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Conductor Strand diameter [mm] ø0.08 Lead wire minimum bending radius [mm] (Reference values) 21 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) D-A72 D-A73 D-A80 0.5 m (Nil) 10 10 10 3 m (L) 47 47 47 5 m (Z) — 77 — Auto switch model Lead wire length Dimensions (mm) 8 4 7 (6) Indicator light D-A80 without indicator light 23 (22) ø3.4 6 (6.2) 3 11.5 (11.7) 15 (14) ø3.2 9 (8.5) Most sensitive position ( ) values for D-A72 1636 Reed Auto Switch Rail Mounting Style D-A7H/D-A80H Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications PLC: Programmable Logic Controller D-A7H (With indicator light) Auto switch model Applicable load Load voltage Max. load current/Load current range(3) Circuit diagram∗ Contact protection circuit Internal voltage drop Indicator light Standard D-A72H D-A73H D-A76H Relay, PLC 200 VAC 5 to 10 mA Relay, PLC IC circuit 24 VDC (4) 4 to 8 VDC 100 VAC 5 to 40 mA 20 mA 5 to 20 mA e t None 2.4 V or less 0.8 V or less Red LED illuminates when turned ON. CE marking D-A80H (Without indicator light) Auto switch model Applicable load Load voltage Maximum load current Circuit diagram∗ Contact protection circuit Internal resistance Standard D-A80H Relay, IC circuit, PLC AC AC 48 V DC 100 V DC 24 or less 50 mA 40 mA 20mA r None 1 Ω or less (Including lead wire length of 3 m) CE marking AC V DC Oilproof Heavy-duty Lead Wire Specifications Auto switch model D-A72H/A73H D-A76H D-A80H Sheath Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue) Insulator Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Conductor Strand diameter [mm] ø0.08 21 Lead wire minimum bending radius [mm] (Reference values) ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model 0.5 m (Nil) Lead wire length 3 m (L) 5 m (Z) D-A72H D-A73H D-A76H D-A80H 10 47 — 10 47 77 11 52 — 10 47 — Dimensions (mm) D-A7H, D-A80H 8 SMC 4 7 15 ø3.2 Indicator light D-A80H without indicator light 2 D- 10.2 3.3 ø3.4 22 6.2 Grommet Electrical entry: In-line 8.5 Most sensitive position 1637 Reed Auto Switch Rail Mounting Style D-A73C/D-A80C Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Connector PLC: Programmable Logic Controller D-A73C (With indicator light) D-A73C Auto switch model Applicable load Relay, PLC Load voltage 24 VDC (5) Load current range (4) Circuit diagram∗ 5 to 40 mA e Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED illuminates when turned ON. Standard Caution Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. Refer to page 1653 for the details. CE marking D-A80C (Without indicator light) D-A80C Auto switch model Applicable load Relay, IC circuit, PLC Load voltage AC 24 V DC Maximum load current Circuit diagram∗ 50 mA Contact protection circuit None Internal resistance r 1 Ω or less (Including lead wire length of 3 m) Standard CE marking ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Lead wire with connector may be shipped with the auto switch. Note 4) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 5) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight Lead wires with a connector indication Part No. of Lead Wires with Connectors (Applicable only for connector type) Model Lead wire length D-LC05 0.5 m D-LC30 3m D-LC50 5m (g) D-A73C D-A80C 0.5 m (Nil) 12 12 3 m (L) 54 54 5 m (Z) 84 84 Auto switch model Lead wire length Dimensions (mm) Lead wire with connector Indicator light D-A80C without indicator light Most sensitive position 1638 Reed Auto Switch Tie-rod Mounting Style D-A5/D-A6 Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-A5 (With indicator light) D-A53 Auto switch model Applicable load Load voltage Maximum load (3) current and range Circuit diagram∗ Contact protection circuit Internal voltage drop Indicator light Standard D-A54 D-A56 PLC 24 VDC (4) 24 VDC (4) Relay, PLC 100 VAC 200 VAC IC circuit 4 to 8 VDC 5 to 50 mA 5 to 50 mA 5 to 25 mA 5 to 12.5 mA 20 mA e None 2.4 V or less q Built-in 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Red LED illuminates when turned ON. CE marking t None 0.8 V or less D-A6 (Without indicator light) Auto switch model Applicable load Load voltage Maximum load current Circuit diagram∗ D-A64 D-A67 Contact protection circuit Relay, PLC 100 VAC 25 mA w Built-in Internal resistance 25 Ω or less AC 24 V DC or less 50 mA Standard 200 VAC 12.5 mA PLC/IC circuit Max. 24 VDC 30 mA r None 1 Ω or less (Including lead wire length of 3 m) CE marking Oilproof Heavy-duty Lead Wire Specifications D-A53/A54 Auto switch model Sheath Outside diameter [mm] Number of cores 2 cores (Brown/Blue) Insulator Outside diameter [mm] Effective area [mm2] 0.3 Conductor Strand diameter [mm] Lead wire minimum bending radius [mm] (Reference values) D-A56 D-A64/A67 ø4 3 cores (Brown/Blue/Black) ø1.22 0.2 ø0.08 24 2 cores (Brown/Blue) 0.3 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model 0.5 m (Nil) 3 m (L) 5 m (Z) D-A53 D-A54 24 48 96 Lead wire length D-A56 D-A64 24 48 — D-A67 24 48 — Dimensions (mm) 14 5 12 22 6 4.5 6 Indicator light D-A64/A67 without indicator light 12 D- 16 11 ø4 33 16 Most sensitive position 1639 Reed Auto Switch Tie-rod Mounting Style D-A33C/D-A34C/D-A44C Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Terminal conduit:D-A3C DIN terminal: D-A44C PLC: Programmable Logic Controller D-A3C (With indicator light) Terminal conduit Auto switch model Applicable load Load voltage Load current range (2) Circuit diagram∗ Contact protection circuit Internal voltage drop Indicator light Standard D-A33C D-A34C PLC 24 VDC (3) 5 to 50 mA Relay, PLC 100 VAC 5 to 25 mA (3) 24 VDC 5 to 50 mA 200 VAC 5 to 12.5 mA e q None 2.4 V or less Built-in 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Red LED illuminates when turned ON. CE marking D-A44C (With indicator light) DIN terminal Caution Auto switch model Applicable load Load voltage Load current range (2) Circuit diagram∗ Contact protection circuit Internal voltage drop Indicator light Standard Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-A44C Relay, PLC 100 VAC 5 to 25 mA (3) 24 VDC 5 to 50 mA 200 VAC 5 to 12.5 mA q Built-in 2.4 V or less (Up to 20 mA)/3.5 V or less (Up to 50 mA) Red LED illuminates when turned ON. CE marking ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 3) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight Auto switch model D-A33C-4, A34C-4 D-A33C-5, A34C-5 D-A33C-6, A34C-6 D-A33C-8, A34C-8 D-A33C-10, A34C-10 (g) Applicable bore size(mm) 40 50 63 80 100 Auto switch model Weight D-A44C-4 D-A44C-5 D-A44C-6 D-A44C-8 D-A44C-10 162 166 184 210 232 Applicable bore size(mm) 40 50 63 80 100 Weight 160 164 182 208 230 Dimensions (mm) Applicable bore Auto switch model size (mm) 40 D-A3C-4, D-A44C-4 50 D-A3C-5, D-A44C-5 63 D-A3C-6, D-A44C-6 80 D-A3C-8, D-A44C-8 100 D-A3C-10, D-A44C-10 4xZ Hexagon socket head cap bolt HW H H' T T' 69 77 91 107 121 58 (67.5) 59 (68.5) 61.5 (71) 65 (74.5) 68 (77.5) 50.5 (60) 51.5 (61) 53 (62.5) 54.5 (64) 57.5 (67) 7.5 8.5 10.5 12.5 15.5 6.5 6.5 7.5 9.5 9.5 ∗ ( ): Denotes the values of D-A44C Dimensions D-A3C C 44 52 64 78 92 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 (Applicable cable O.D. ø6.8 to ø9.6) D-A44C 4xZ Hexagon socket head cap bolt 1640 M5 x 0.8 x 16 M5 x 0.8 x 20 M5 x 0.8 x 25 (mm) 2 x M5 x 0.8 x 12 Hexagon socket head cap bolt Tightening gland G 1/2 (Applicable cable O.D. ø6.8 to ø11.5) Indicator light Most sensitive position Z Most sensitive position Reed Auto Switch Direct Mounting Style D-Z73/D-Z76/D-Z80 Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-Z7 (With indicator light) Auto switch model D-Z73 D-Z76 Applicable load Relay, PLC IC circuit Load voltage 100 VAC 24 VDC (4) 4 to 8 VDC Max. load current and load current range(3) 5 to 40 mA 5 to 20 mA 20 mA Circuit diagram∗ e t Contact protection circuit None Internal voltage drop 2.4 V or less (Up to 20 mA)/3 V or less (Up to 40 mA) 0.8 V or less Indicator light Red LED illuminates when turned ON. Standard CE marking D-Z8 (Without indicator light) D-Z80 Auto switch model Applicable load Relay, PLC, IC circuit AC 24 V DC or less Load voltage 50 mA Maximum load current Circuit diagram∗ Contact protection circuit Internal resistance Standard AC 48 V DC AC 100 V DC 20 mA 40 mA r None 1 Ω or less (Including 3 m lead wire) CE marking Oilproof Heavy-duty Lead Wire Specifications Auto switch model D-Z73 D-Z76 D-Z80 ø3.4 ø2.7 ø2.7 Outside diameter [mm] Sheath Number of cores 2 cores (Brown/Blue) 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue) Insulator ø1.1 Outside diameter [mm] 0.18 0.2 0.18 Effective area [mm2] Conductor ø0.08 Strand diameter [mm] 17 21 17 Lead wire minimum bending radius [mm] (Reference values) ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model 0.5 m (Nil) Lead wire length 3 m (L) 5 m (Z) D-Z73 D-Z76 D-Z80 7 31 50 10 55 — 7 31 — Dimensions (mm) D-Z73, Z80 D-Z76 M2.5 x 4L Slotted set screw M2.5 x 4L Slotted set screw 27.6 30.5 1.5 2.5 6.2 6.2 2.3 Indicator light D-Z80 without indicator light Indicator light Most sensitive position 12.5 Most sensitive position ø3.4 12.5 ø2.7 5.5 5.7 D- 1641 Reed Auto Switch Direct Mounting Style D-E73A/D-E76A/D-E80A Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-E7A (With indicator light) Auto switch model Applicable load Load voltage Max. load current and load current range(3) Circuit diagram∗ Contact protection circuit Internal voltage drop Indicator light Standard D-E73A D-E76A Relay, PLC 100 VAC 24 VDC (4) 5 to 40 mA 5 to 20 mA e None IC circuit 4 to 8 VDC 20 mA t 2.4 V or less 0.8 V or less Red LED illuminates when turned ON. CE marking D-E80A (Without indicator light) D-E80A Auto switch model Applicable load Load voltage Maximum load current Circuit diagram∗ Relay, PLC, IC circuit AC AC 48 V DC 100 V DC 40 mA 20 mA r None 1 Ω or less (Including lead wire length of 3 m) CE marking AC 24 V DC or less 50 mA Contact protection circuit Internal resistance Standard Oilproof Heavy-duty Lead Wire Specifications Auto switch model D-E73A D-E76A D-E80A ø3.4 Outside diameter [mm] Sheath Number of cores 2 cores (Brown/Blue) 3 cores (Brown/Blue/Black) 2 cores (Brown/Blue) Insulator ø1.1 Outside diameter [mm] 0.2 Effective area [mm2] Conductor ø0.08 Strand diameter [mm] 21 Lead wire minimum bending radius [mm] (Reference values) ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Note 4) The auto switches can operate at 12 VDC, but consider the internal voltage drop of the auto switch described in Reed Auto Switch Precautions on page 12. Weight (g) Auto switch model 0.5 m (Nil) 3 m (L) D-E73A D-E76A D-E80A 10 47 11 55 10 47 Lead wire length Dimensions (mm) 8 8 Indicator light D-E80A without indicator light 22 8.5 12.5 3 6 ø3.4 D-E73A 2.7 1642 SMC 6 2.4 0.5 0.5 Most sensitive position 6.4 0.5 2-Color Indication Type Reed Auto Switch Band Mounting Style D-B59W Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-B59W (With indicator light) D-B59W Auto switch model Applicable load Relay, PLC Load voltage 24 VDC Load current range(3) Circuit diagram∗ 5 to 40 mA y Contact protection circuit Built-in Internal voltage drop 4 V or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking Oilproof Heavy-duty Lead Wire Specifications D-B59W Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Lead wire minimum bending radius [mm] (Reference values) ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Weight (g) D-B59W Auto switch model Lead wire length 0.5 m (Nil) 20 3 m (L) 76 Dimensions (mm) 33 12 15 ø4 13 Indicator light 6.5 6.5 9.5 0.5 14.3 The proper operating range can be determined by the color of the light. (Red → Green ← Red) ø4.5 D- 12.6 Most sensitive position 1643 2-Color Indication Type Reed Auto Switch Rail Mounting Style D-A79W Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-A79W (With indicator light) D-A79W Auto switch model Applicable load Relay, PLC Load voltage 24 VDC Load current range (3) Circuit diagram∗ 5 to 40 mA u Contact protection circuit None Internal voltage drop 4 V or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking Oilproof Heavy-duty Lead Wire Specifications D-A79W Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø3.4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.1 Effective area [mm2] 0.2 Strand diameter [mm] ø0.08 Lead wire minimum bending radius [mm] (Reference values) 21 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Weight (g) D-A79W Auto switch model Lead wire length 0.5 m (Nil) 11 3 m (L) 53 Dimensions (mm) 8 ø3.2 4 7 15 Indicator light 23.5 6.2 14 3 1.8 ø3.4 11.5 1644 Most sensitive position 2-Color Indication Type Reed Auto Switch Tie-rod Mounting Style D-A59W Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-A59W (With indicator light) D-A59W Auto switch model Applicable load Relay, PLC Load voltage 24 VDC Load current range(3) Circuit diagram∗ 5 to 40 mA y Contact protection circuit Built-in Internal voltage drop 4 V or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light Standard CE marking Oilproof Heavy-duty Lead Wire Specifications D-A59W Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø4 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø1.22 Effective area [mm2] 0.3 Strand diameter [mm] ø0.08 24 Lead wire minimum bending radius [mm] (Reference values) ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Weight (g) D-A59W Auto switch model Lead wire length 0.5 m (Nil) 25 3 m (L) 80 Dimensions (mm) 6 14 7 13 23 ø4 4.9 ø4.5 Indicator light 12 0.5 33 D- 16 11 The proper operating range can be determined by the color of the light. (Red → Green ← Red) 12 Most sensitive position 1645 Magnetic Field Resistant 2-Color Indication Type Reed Auto Switch D-P79WSE (Electrical Entry: Pre-wired connector) Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet The proper operating range can be determined by the color of the light. (Red → Green ← Red) PLC: Programmable Logic Controller D-P79WSE Auto switch model Applicable load PLC Load voltage 24 VDC Load current range Circuit diagram∗ 8 to 20 mA y Contact protection circuit Built-in Internal voltage drop 6 V or less Operating range .......... Red LED illuminates. Proper operating range .......... Green LED illuminates. Indicator light CE marking Standard Oilproof Heavy-duty Lead Wire Specifications Caution Precautions Cylinder with a strong integrated magnet must be used. D-P79WSE Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø6 Number of cores 2 cores Outside diameter [mm] ø2.3 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 Lead wire minimum bending radius [mm] (Reference values) 48 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Weight (g) D-P79WSE Auto switch model 100 Dimensions (mm) D-P79WSE Indicator light Connector size M12 32 ø14 SMC D-P79W DC24V MADE IN JAPAN 14.6 Heat shrink tube Note) 5 Soft resin mold surface (Mounting surface for the switch mounting bracket side) 300 44 2 x 2 x ø6 Counterbore depth 2.4 2 x ø3.4 through 20 4 ø6 5 16 Most sensitive position Note) D-P79WSE = “SE 1 4-” Caution Please be careful of the mounting direction. The soft resin mold surface must be directed to the switch mounting bracket side. 1646 Magnetic Field Resistant Reed Auto Switch D-P74 Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications Grommet PLC: Programmable Logic Controller D-P74L/Z (With indicator light) D-P74 Auto switch model Grommet Electrical entry Relay, PLC Application Load voltage Max. load voltage/Load current range Circuit diagram∗ 24 VDC 100 VAC 5 to 40 mA 5 to 20 mA q Built-in Contact protection circuit 2.4 V or less Internal voltage drop (internal resistance) 0 Leakage current Standard CE marking Oilproof Heavy-duty Lead Wire Specifications D-P74 Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø6.8 Number of cores 2 cores (White/Black) Outside diameter [mm] ø1.1 Effective area [mm2] 0.75 Strand diameter [mm] ø0.18 48 Lead wire minimum bending radius [mm] (Reference values) ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Refer to page 1568 for lead wire lengths. Note 3) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Weight (g) D-P74 Auto switch model Lead wire length 3 m (L) 189 5 m (Z) 320 Dimensions (mm) SMC 13.6 Indicator light 32 5 2 x 2 x ø6 Counterbore depth 2.4 5 ø6.8 2 x ø3.4 through 4 Precautions Cylinder with a strong integrated magnet must be used. D- 20 Caution Red LED illuminates when turned ON. Indicator light 16 Most sensitive position 1647 A Magnetic Field Resistant Reed Auto Switch D-P74-376 Auto Switch Specifications Grommet Refer to SMC website for the details of the products conforming to the international standards. PLC: Programmable Logic Controller D-P74-376 (With indicator light) D-P74-376 Auto switch model Grommet Electrical entry Relay, PLC Application 24 VDC Load voltage 5 to 20 mA Max. load current/Load current range Circuit diagram∗ q Built-in Contact protection circuit 2 V or less Internal voltage drop (internal resistance) 0 Leakage current Caution Precautions Cylinder with a strong integrated magnet must be used. Operating time 1.2 ms Indicator light Red LED illuminates when turned ON. CE marking Standard Oilproof Heavy-duty Lead Wire Specifications D-P74 Auto switch model Sheath Insulator Conductor Outside diameter [mm] ø6 Number of cores 2 cores Outside diameter [mm] ø1.1 Effective area [mm2] 0.75 Strand diameter [mm] ø0.18 Lead wire minimum bending radius [mm] (Reference values) 48 ∗ Refer to the circuit diagram no. on page 1571. Note 1) Refer to page 1568 for reed auto switch common specifications. Note 2) Under 5 mA, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2.5 mA. However, there is no problem in terms of contact output, when an output signal exceeds 1 mA or more. Weight (g) D-P74-376 Auto switch model 60 Dimensions (mm) ø14 Connector size M12 SMC 13.6 Indicator light 32 5 500 2 x 2 x ø6 Counterbore depth 2.4 2 x ø3.4 through 20 4 ø6 5 16 1648 Most sensitive position 44.5 Heat Resistant Reed Auto Switch D-B30(J)/31(J)/35(J) Can be used outdoors or under high temperature (Max. 120°C). Wide operating range (double that of other SMC products) enables stable position detection. Refer to SMC website for the details of the products conforming to the international standards. Auto Switch Specifications PLC: Programmable Logic Controller D-B30 Auto switch model Electrical entry Operating voltage D-B30J Terminal conduit D-B31 Terminal Grommet Operating current range 5 to 30 mADC / 5 to 20 mAAC 2.5 V or less Indicator light Without indicator light Applicable load Outdoor plants and environment with high temperature and humidity D-B35 Terminal conduit D-B35J Grommet 100 VAC 24 VDC 5 to 20 mAAC 5 to 30 mADC 2.5 V or less 2.0 V or less Neon bulb lights up when OFF Red LED lights up when OFF PLC (Programmable Logic Controller) 300 m/s2 Shock resistance High temperature environment such as places around ignited gas outlet or furnace Grommet conduit 24 VDC / 100 VAC Internal voltage drop D-B31J Leakage current 0.1 mA or less Lead wire — 1 mA or less 0.5 m — 1 mA or less 0.5 m — 0.5 m Terminal conduit : IEC60529 IP64 Enclosure Grommet : IEC60529 IP67 Withstand voltage 1500 VAC for 1 minute (between case and terminals or lead wires) Environment for steam cleaning or high temperature sterilization Insulation resistance Applications requiring wide operating range such as clamping of elastic work pieces 50 MΩ or larger between case (ground) and lead wires (terminals) –10C to 120C Standard Use of metal case and heat resistant materials. The construction prevents influence of external environment by sealing the auto switch internal parts to improve heat resistance. The wide operating range allows easy position setting and reduces influence of the work piece position changes. Auto Switch Internal Circuit Operating temperature range CE marking Oilproof Heavy-duty Lead Wire Specifications D-B30J Auto switch model Sheath Insulator Conductor D-B31J D-B35J Outside diameter [mm] ø6 Number of cores 2 cores (Brown/Blue) Outside diameter [mm] ø2.3 Effective area [mm2] 0.5 Strand diameter [mm] ø0.08 Lead wire minimum bending radius [mm] (Reference values) 48 (Room temperature) D-B30 Contacts protection resistance () Reed switch Weight (g) () D-B30 D-B30J D-B31 D-B31J D-B35 None 190 — 190 — 190 — 0.5 m (Nil) — 250 — 250 — 250 3 m (L) — 268 — 268 — 268 5 m (Z) — 462 — 462 — 462 Auto switch model Lead wire length D-B31 D-B35J Contacts protection resistance () Reed switch Current limiting Neon bulb resistance () Lead wire length In case of the grommet type (J type), the lead wire length is 0.5 m. (No lead wire is attached to the terminal conduit type.) Manufacture of 3 m and 5 m types is also possible. Please consult SMC for these types. D-B35 Reed switch () Contacts protection resistance () Current limiting resistance D- Light emitting diode (LED) Diode 1649 Series D-B3 Dimensions (mm) Terminal conduit type D-B3 Terminal conduit type D-B3J 42 42 500 59 ø6 59 38 38 G 1/2 41.5 41.5 85 35 35 69 8 8 42 12 59 85 ∗ Recommended minimum bending radius for lead wire RT : 25 mm or more 120°C : 50 mm or more Terminal part Dimensions for Cylinder Mounting Hs dimensions Hs 59 (mm) Cylinder model Bore size CDA2 MDB 40 mm 50 mm 63 mm 80 mm 100 mm 58.5 64 71 79.5 90 57.5 63 69.5 78.5 89 Mounting cylinder part no. CDA2 B 50 – 200 – B31J S – X1184 With built-in special magnet Cylinder stroke Cylinder bore size Mounting Cylinder model Description Symbol CDA2 Series CDA2 (Bore size 40 to 100) Series MDB (Bore size 40 to 100) MDB 1650 Number of auto switches Symbol Nil S Description 2 pcs. 1 pc. Auto switch type Symbol Nil B30 B30J B31 B31J B35 B35J Description Without auto switch D-B30 D-B30J D-B31 D-B31J D-B35 D-B35J ∗ Please consult SMC in case the switch is to be mounted on models other than applicable cylinders. Series D-B3 Specific Product Precautions Be sure to read before handling. Refer to front matter 57 for Safety Instructions and pages 8 to 12 for Auto Switch Precautions. Caution 1. Use the reed switch within the operating range. Take precautions about the ambient temperature because using the reed switch beyond the operating range may affect its internal electronic parts and sealing construction, causing abnormalities to the service life of the contact, as well as operation and waterproof performance of the switch. Also, the maximum temperature of the environment where the switch is used must be fully understood before operation is started because the temperature of the environment where the auto switch is installed may experience some changes after operation is started due to factors other than air temperature such as influence of radiation heat from the heat source, air circulation or heat conduction. 2. Take precautions about the environment where the auto switch is installed. If conditions (water splashes, time, temperature) beyond the normal ranges can be applied to the auto switch, use the auto switch in an environment where it will not be directly exposed to water splashes at a high temperature by installing a cover to protect the entire auto switch, as long as it is possible. The grommet type auto switch has a construction that will protect its internal parts against water splashes at the normal temperature. However, if the conditions (water splashes, time, temperature) exceed the normal ranges, they may adversely affect the auto switch internal insulation performance. Also, confirm the applicability of the auto switch in the environment because extreme heat cycles or a long-term high humidity may cause functional deterioration of the auto switch protection construction. In principle, the terminal conduit type must be used in an environment with no exposure to humidity or water because at high temperatures, it may become impossible to achieve sufficient waterproof effect due to deformation of lead wire sealant depending on the heat resistance of the lead wire and cable clamp. 3. Visibility of an indicator light Because the auto switch uses light emitting diodes and neon bulbs for display, continuous operation at a high temperature may cause changes in characteristics of the entire display circuit. Also, the transparency of the display window on the body may change depending on the characteristics of the resin. Because of the above factors, lighting under high temperature may become dark, causing decline of visibility. However, there could be no problem in output of the signal itself and its safety owing to adoption of the OFF-state lighting system. 4. Take precautions about leakage current. According to the heat resistant characteristics of its parts, the auto switch adopts the OFF-state lighting system (the indicator light lights up when the reed switch contact is open and goes off when the reed switch contact is closed). Since the current for indication lighting is running when the auto switch is off, confirm the allowable leakage current of PLC etc. before selecting the model. If the leakage current of the indicator light becomes a problem for the PLC operation, select a model without an indicator light. 5. Keep the lead wire length as short as possible. If a long lead wire is used because of the conditions of the plant or equipment where the switch is installed, malfunction in the reed switch reset operation may occur due to premature damage to the contact surface caused by the inrush current resulting from the line flotation capacity and influence of the electric field created by the power line near the wiring. Therefore, the maximum wiring length should be kept at 100 m or less. Avoid wiring in proximity with the power line. Also, if the length of wiring in use is extremely long (30 m or longer), schedule replacement in periodical maintenance. The basic guidelines for replacement are a total wiring length of 100 m between the load and the auto switch and 1 million cycles of operation (at 120°C , 100VAC PLC load). 6. Install the auto switch at the center of the operating range. The operation range of the auto switch is set at approximately double that of the standard type in consideration of the mounting error when the detection position is set. However, this range is subject to change with the temperature. Although the variation in the operating range differs with the cylinder on which the auto switch is mounted, a temperature change of 100°C will roughly result in the maximum of 20% reduction in the overall operation range. (Approximately 2 mm variation at the position where the auto switch usually turns on ) Therefore, install the auto switch at the center of the operating range (stable range), while understanding the possible change in the operating range and considering the stability of the auto switch operation. (Avoid installation of the auto switch at the boundary where the auto switch turns on or off.) 7. Selection of applicable cylinders The auto switch should be mounted on special cylinders (Series X1184) because it is operated by magnets using heat resistant material. Consult SMC in advance for special applications in which conventional cylinder cannot be used because, depending on the operating environment, it is possible that special measures should be taken or even the cylinder cannot be adapted. 8. Maintenance After the auto switch is installed under high temperature, apply additonal tightening peiodically to the auto switch mounting band. The rubber lining of the auto switch mounting band may need some time to adapt to the environment because of temperature chages in the installation environment. Perform additoinal tightening at a tightening torque of 2 to 3 N⋅m while carefully applying equal torque to both lifting screws. 9. Product upgrades The product is subject to change without prior notice due to upgrades. D- 1651