SES MAPPS CLASS I DIV II Design and Pricing Guide 4-30-12

advertisement
MAPPS CSA Class I DIV II Solar Power Systems for Hazardous Locations
Design and Pricing Guide
1. CALCULATE YOUR POWER REQUIREMENTS
Figure your load in Watt-hours per day. Consider both continuous and intermittent loads in a
24-hour period. Average over a week if loads change daily.
2. DETERMINE YOUR SOLAR INSOLATION ZONE
Locate your site on the map below. The map represents average solar energy available in the
winter. Available energy increases incrementally from zones 1 through 5.
3. USE THE PERFORMANCE TABLE TO CHOOSE YOUR SYSTEM
The tables below represent the Watt-hours per day performance of each MAPPS system in the different
solar zones. Choose your system voltage, then look down your solar zone column for the value that
meets or exceeds your design load Watt-hours. Follow the row to the left for the corresponding
prepackaged MAPPS system that will fully power your load requirements.
Complimentary solar sizing analysis for your location can be provided with quotation
12 Volt MAPPS System Specifications
12 Volt DC Systems
Solar
Battery
MAPPS
ID Number
Array
Wattage
MAP-85-216-12-C1D2
85
MAP-130-216-12-C1D2
135
MAP-170-216-12-C1D2
170
MAP-170-432-12-C1D2
170
MAP-260-216-12-C1D2
270
MAP-260-432-12-C1D2
270
Wholesale Pricing available for OEM's,
Capacity
Watt-hr
Zone 1
MAPPS
Whr/d
Zone 2
MAPPS
Whr/d
Zone 3
MAPPS
Whr/d
1866
55
111
166
1866
88
176
263
1866
111
221
332
3732
111
221
332
1866
176
351
527
3732
176
351
527
distributors, integrators & dealers
Zone 4
MAPPS
Whr/d
Zone 5
MAPPS
Whr/d
217
344
434
434
689
689
691
691
691
691
848
1696
List
Price
$ 4,388
$ 4,640
$ 4,964
$ 6,313
$ 5,324
$ 6,673
MAPPS CSA Class I DIV II Solar Power Systems for Hazardous Locations
Design and Pricing Guide (p.2)
24 Volt MAPPS System Specifications
24 Volt DC Systems
Solar
Battery
MAPPS
ID Number
Array
Wattage
MAP-100-108-24-C1D2
40
MAP-200-108-24-CI1D2
100
MAP-200-216-24-CI1D2
200
MAP-260-108-24-C1D2
260
MAP-260-216-24-C1D2
370
MAP-400-216-24-C1D2
400
MAP-600-216-24-C1D2
600
MAP-600-432-24-C1D2
600
MAP-800-432-24-C1D2
800
Wholesale Pricing available for OEM's,
Capacity
Watt-hr
Zone 1
MAPPS
Whr/d
Zone 2
MAPPS
Whr/d
Zone 3
MAPPS
Whr/d
1866
26
52
78
1866
65
130
195
3732
130
260
390
1866
169
338
507
3732
241
481
722
3732
260
520
780
3732
390
780
1170
7465
390
780
1170
7465
520
1040
1560
distributors, integrators & dealers
Zone 4
MAPPS
Whr/d
Zone 5
MAPPS
Whr/d
102
255
510
663
944
1020
1530
1530
2040
115
691
691
848
848
1696
1696
1696
3392
List
Price
$ 4,712
$ 4,964
$ 6,313
$ 5,324
$ 6,673
$ 7,447
$ 8,581
$ 13,849
$ 14,983
Load Power Requirement Example:
Test the actual power draw of the equipment if you can. Add up all the loads in Watt-hr/day
12 VDC example: 1.2 Amps X 12 Volts = 14.4 Watts X 24 hr/day = 346 Watt-hr/Day
Solar Electric Supply Inc. Headquarters
2880 Research Park Dr. Suite 100, Soquel, CA 95073 831-462-8243 www.solarelectricsupply.com
Features
•
•
•
•
•
•
High efficiency UL Listed, Class I Div II rated solar panels Heavy-duty aluminum pole mounting
structure with stainless steel hardware
Solar array Class I Div II approved conduit wiring harness kit
UL Listed NEMA 3R/NEMA 4 durable powder-coated white aluminum battery control and
component enclosure, lockable, includes sticker on inside door with specific Class I Div II
certification
Sealed gel cell, maintenance free, deep-cycle, non-spillable batteries, UL Recognized
Advanced Charge Control, Class I Div II rated, with low voltage load protection and temperature
compensated battery charging
Extra room for your equipment - each system package has roughly 12 cu/in of extra space in the
electronics compartment. There is plenty of room for you to add your own Class I Div II rated
SCADA, radio, GPS, telemetry, VSAT, Wi-Fi or other electronic equipment.
CSA Approved Class I, Div. II hazardous location safety rating
Download