Reflect-A-Bay Gen2 Linear Fluorescent High Bay Technical Specifications REFLECT-A-BAY Simkar’s Reflect-A-Bay™ Gen2 offering is the perfect complement to our broad offering of industrial high bay products. Incorporating our unique spring latch, swing down, one piece reflector system, the RG2 fluorescent high bay is offered in both T5HO or T8 in four, and six lamp configurations. Coupled with a wide array of options and accessories, RG2 is the perfect choice for manufacturing, warehouse, retail or institutional applications, for new installations or retrofits. • Spring loaded latches secure one-piece reflector for swing down access into ballast chamber for toolless wiring • Energy efficient – up to 50% energy savings vs. HID • Chain, pendant, cable, hook, and surface mounting options HOUSING Die-formed heavy gauge steel housing with high-gloss baked white enamel finish over rust inhibiting phosphate coat. Die-formed steel end caps with center 7/8” KOs, and (2) 1/2" KOs, attaching via center interlocking tab into housing, secured by 2 screws. Smooth housing edges for ease of handling. Quick access plate located in center of housing. OPTICS Lamp tray combines sockets and reflectors; three reflector material options are available. Two distributions available; white reflector (wide distribution) and 87% reflective specular aluminum reflector (narrow distribution). 95% reflective specular aluminum reflector optional. ELECTRICAL Fully wired for 120-277V, 60 Hz AC operation with ETL-CBM, thermally protected, automatic resetting, Class P, sound rated A, programmed-start, electronic T5 HO or instant start T8 ballast. CEE and NEMA Premium T8 ballasts also available. The 4 lamp unit contains (1) 4-lamp ballast as standard. The 6 lamp unit contains (1) 2-lamp and (1) 4-lamp ballast. Rotolock sockets. Units suitable for ambient temperatures up to 131˚ F (55˚ C). Pr ojec t C at alog N um ber Ty pe D at e • Choice of reflectors: high specular aluminum with narrow distribution, or white for wide distribution applications • T5HO and T8 versions with 4 or 6 lamps • Operating range up to 131˚ F (55˚ C). 6 Lamp version shown SENSORS RG2 can be specified with PIR (Passive Infrared) occupancy sensors or daylight sensors.Title 24 compliant sensors available. ACCESS / WIRING Center quick access plate on top of unit features 7/8" KO and allows access to ballast disconnect(s). Two 1/2” KOs and one 7/8" KO per end cap. Reflector tray and optional lens feature toolless, spring-loaded quickrelease latches that allow reflector and optional lens to swing down independently to access ballast chamber. 14" 3 3/8" 4 Lamp version shown T5 T T MOUNTING Recommended mounting heights up to 50 T feet. Pendant, slide box, chain, hook, and aircraft cable T5 T T8 configurations available. May be surface mounted via T8 L ED T12 slide box. T12 T 5 L ED T 8 T 5 T 8 T T T T LISTINGS UL Listed damp location. MADE IN THE UNITED STATES Reflect-A-Bay Gen2 Linear Fluorescent High Bay Configuration SERIES RG2 # LAMPS 4 6 LAMP TYPE* 32 = 32W T8 48” 54 = 54W T5HO 46” REFLECTOR SR = Specular aluminum 87% reflectivity (standard) WR = White MR = Specular aluminum 95% reflectivity BALLAST** E = Electronic T8 HE = Electronic T5HO PS(x)** = T8 only, program start (L) = Low BF (N) = Normal BF (H)=High BF HP(x)**= T8 only, high performance (L) = Low BF (N) = Normal BF (H) = High BF CS = Customer supplied B9 = Customer specified SWITCHING For 4 lamp units 4L = (1) 4 Lamp ballast 22L = (2) 2 Lamp ballasts VOLTAGE U1 = 120-277V 34 = 347V 48 = 480V For 6 lamp units 4L2L = (1) 4 Lamp ballast & (1) 2 Lamp ballast 23L = (2) 3 Lamp ballast 32L = (3) 2 Lamp ballast *Nominal. See performance table for actual power consumption. Tube guards are NOT recommended on T5 lamps. **CEE Listed; for NEMA Premium, and for detailed ballast information, please contact factory OPTIONS BP = Bulk pack FB = Fast blow fuse SB = Slow blow fuse Sensors (factory wired; see switching; for daylight harvesting, please contact factory) OS(x)* = PIR Occupancy sensor (specify # of lamps controlled - 2, 4, or 6) OSPC(x) = PIR Occupancy sensor with photocontrol (specify # of lamps controlled - 2, 4, or 6) 6’ Cord and Plug CPT(x): 1 = 120V, (L5-15P); 2 = 277V, L7-15P) 3 = 208V, (L6-15P); 4 = 240V, (L6-15P) 5 = 480V, (L8-20P); CP3 = Cord & plug-120V straight blade 5-15P C6 = 6' Cord (Cord only); C10 = 10' Cord (Cord only) EMERGENCY OPTIONS ACCESSORIES ELS1 = 500 lumens (T8 only) 4 Lamp Units ELS2 = 700 lumens RG2F4 = Frosted acrylic flat lens ELS3 = 1400 lumens RG2C4 = Clear acrylic flat lens RG2WG4 = Wire guard 6 Lamp Units RG2F6 = Frosted acrylic flat lens RG2C6 = Clear acrylic flat lens RG2WG6 = Wire guard Note: Wire Guards can be installed in conjunction with Lenses. Note: Tube guards not recommended for use with T5HO lamps. MOUNTING ACCESSORIES CA24 = Chain hanger assembly: (2) 18" chains, (2) v-hooks, (2) s-hooks; 24" total drop CS24 = S-hook chain hanger assembly: (4) 18" chain & (4) s-hooks; 24" total drop RG2SBH = Center slide box with hook assembly RG2SBP = Center slide box for single pendant mount or surface mount SP(x) = Swivel pendant mount; white stem; specify length: (24”/ 36”/ 48”/ 60” / 72”) (Used with RG2SBP) PM2(X) = Twin pendant mount, (2) white stems (without canopies); specify length (24"/ 36"/ 48"/ 60" / 72") HKSC = Hook & chain assembly; includes (4) 31.5" chains, mounting plate, and hook CAB(X)72 = Adjustable aircraft cables; specifiy "2" for (2) cables joined with Y hanger, or "4" for (4) individual 72" cables; includes tooless adjusters and mounting hardware Lamps (installed): (x) specify series (7 = 700, 8 = 800) (y) specify color (35, 41, 50) * For OS to control 2L, need correct ballast configuration FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11202015 REV E (800) 523-3602 • www.simkar.com Reflect-A-Bay Gen2 Linear Fluorescent High Bay Technical Specifications Mounting Accessories CA24 HKSC RG2SBH Chain hanger (2) assembly Hook & chain assembly Center mount slide box w/hook assembly CS24 PM2(x) RG2SBP “S” Hook (4) Chain hanger assembly Twin pendant mount Center mount slide box for single pendant or surface mount SEE ORDERING INFO CAB(x)72 Adjustable aircraft cables SEE ORDERING INFO Dimensions 7/8" KO 1/2" KO RG2 - 4 Lamp 3 5/8 " 2 7/8" 2 3/8" 6" 3/8" 13 3/8" RG2 - 6 Lamp 19 3/8 " RG2 - 4 & 6 Lamp 48" FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11202015 REV E (800) 523-3602 • www.simkar.com Reflect-A-Bay Gen2 Linear Fluorescent High Bay Technical Specifications Photometric Data Luminaire Data - 54W White Reflector Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency RG2454WRHEU1 UL1018378 (4) 54W T5 4450 Philips Advance Centium ICN4S54-90C-2LS-G 1.00 228.9 16,015 90.0% Utilization of Lumens CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 19052 17042 15264 13760 12497 11425 10504 9706 9011 8402 7864 50 19052 16122 13729 11843 10356 9161 8184 7374 6696 6121 5630 30 19052 15298 12459 10360 8788 7579 6628 5864 5240 4724 4292 10 19052 14556 11391 9178 7590 6412 5511 4805 4240 3781 3402 50 17771 15042 12816 11073 9705 8611 7717 6976 6354 5826 5374 50 30 17771 14418 11826 9888 8426 7297 6403 5682 5091 4601 4189 10 17771 13845 10970 8913 7414 6289 5423 4739 4190 3742 3371 30 30 17008 13883 11436 9594 8200 7119 6260 5566 4996 4522 4123 50 17008 14395 12267 10607 9311 8276 7432 6731 6144 5644 5216 10 17008 13408 10706 8743 7300 6210 5365 4696 4158 3717 3351 Zonal cavity method Effective floor reflectance = 20% Candela Plot 105 120 135 150 180 150 135 120 105 90 Zonal Lumens and Percentages 90 Luminance Summary (Candela/M 2 ) ZONE LUMENS % LUMINAIRE ANGLE 0-DEG 45-DEG75 90-DEG 0-40 0-60 0-90 90-180 5582.3 10873.2 15980.6 34.4 34.9 67.9 99.8 0.2 0 45 55 65 75 85 10830 10240 9808 9024 7495 4046 10830 13120 14580 17310 21150 21140 10830 14900 17330 20750 24950 18700 60 SC: 0-180: 1.26 90-270: 1.53 75 1000 2000 60 3000 45 45 4000 30 Photometric Data Luminaire Data - 54W Specular Reflector Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency RG2454MRHEU1 UL1108371 (4) 54W T5 4600 Philips Advance Centium ICN-4S54-90C-2LS-G 1.00 237.5 16,900 91.8% 15 15 0 30 0 Deg. Plane 90 Deg. Plane Utilization of Lumens CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 20117 18386 16773 15353 14120 13043 12097 11262 10523 9866 9280 50 20117 17582 15399 13608 12140 10924 9903 9037 8296 7658 7103 30 20117 16861 14263 12257 10691 9443 8430 7595 6896 6305 5801 10 20117 16211 13307 11181 9584 8350 7374 6584 5934 5392 4934 50 18776 16478 14481 12840 11496 10381 9442 8644 7959 7367 6851 50 30 18776 15937 13602 11767 10318 9154 8201 7410 6746 6181 5697 10 18776 15441 12841 10883 9386 8214 7276 6512 5880 5351 4901 30 30 17977 15376 13194 11462 10085 8972 8056 7293 6650 6102 5631 50 17977 15817 13929 12376 11105 10050 9160 8402 7752 7187 6695 10 17977 14968 12549 10694 9258 8125 7213 6466 5845 5323 4880 Zonal cavity method Effective floor reflectance = 20% Candela Plot 105 120 135 150 180 150 135 120 105 90 Zonal Lumens and Percentages 90 Luminance Summary (Candela/M 2 ) 75 ZONE LUMENS % LUMINAIRE ANGLE 0-DEG 45-DEG 0-40 0-60 0-90 90-180 8303 13390 16900 0 49.1 79.2 100.0 0.0 0 45 55 65 75 85 22140 19650 18070 16290 12580 1191 22140 11690 11150 10720 13060 12450 SC: 0-180: 1.23 90-270: 1.23 75 2000 90-DEG 60 22140 11870 11610 13060 14590 12230 60 4000 6000 45 45 8000 30 15 180 Deg. Plane FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11202015 REV E 0 15 0 Deg. Plane (800) 523-3602 • www.simkar.com 30 90 Deg. Plane Reflect-A-Bay Gen2 Linear Fluorescent High Bay Technical Specifications Photometric Data Luminaire Data - 54W White Reflector Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency RG2654WRU1 UL1051970 (6) 54W T5 4450 (1) Phillips Advance Centium ICN-4S54-90C-2LS-G and (1) Philips Advance Centium ICN-2S54-90C-N 1.00 354.7 24,250 90.8% Utilization of Lumens CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 28853 25678 22946 20656 18746 17131 15745 14547 13506 12592 11788 50 28853 24230 20557 17692 15448 13654 12192 10982 9970 9112 8380 30 28853 22933 18580 15398 13033 11225 9807 8671 7746 6981 6341 10 28853 21764 16918 13571 11189 9432 8096 7051 6218 5542 4984 50 26902 22577 19157 16510 14450 12811 11475 10370 9445 8660 7988 50 30 26902 21592 17614 14677 12480 10792 9461 8391 7517 6791 6182 10 26902 20689 16281 13167 10920 9245 7960 6950 6141 5481 4936 30 30 25740 20777 17019 14228 12133 10519 9242 8213 7370 6669 6080 50 25740 21586 18314 15795 13844 12297 11037 9995 9122 8381 7745 10 25740 20028 15881 12910 10747 9124 7871 6883 6090 5441 4904 Zonal cavity method Effective floor reflectance = 20% Candela Plot 105 120 135 150 180 150 135 120 105 90 Zonal Lumens and Percentages 90 Luminance Summary (Candela/M 2 ) ZONE LUMENS % LUMINAIRE ANGLE 0-DEG 45-DEG75 90-DEG 0-40 0-60 0-90 90-180 8115 14543 24170 81 33.5 65.8 99.7 0.3 0 45 55 65 75 85 10340 9707 9278 8495 6951 3705 10340 12560 14250 17350 23350 25020 10340 14570 17300 21710 28110 24770 60 SC: 0-180: 1.25 90-270: 1.25 75 1500 3000 60 4500 45 45 6000 7500 30 Photometric Data Luminaire Data - 54W Specular Reflector Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency RG2654SRHEU1 UL1108370 (6) 54W T5 4600 (1) Phillips Advance Centium ICN-4S54-90C-2LS-G and (1) Philips Advance Centium ICN-2S54-90C-N 1.00 358.4 25,610 92.8% 15 0 180 Deg. Plane 15 270 Deg. Plane 30 0 Deg. Plane 90 Deg. Plane Utilization of Lumens CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 30489 27798 25337 23185 21321 19697 18270 17011 15898 14907 14023 50 30489 26550 23224 20511 18297 16466 14929 13626 12512 11551 10715 30 30489 25432 21475 18441 16083 14208 12686 11432 10383 9495 8736 10 30489 24424 20004 16792 14391 12541 11077 9894 8920 8107 7419 50 28456 24873 21827 19343 17317 15640 14229 13029 12000 11109 10333 50 30 28456 24033 20473 17698 15518 13769 12339 11152 10155 9307 8580 10 28456 23262 19302 16344 14093 12335 10930 9786 8839 8044 7370 30 30 27245 23183 19855 17236 15163 13492 12119 10974 10010 9187 8479 50 27245 23869 20987 18637 16722 15137 13801 12663 11685 10836 10095 10 27245 22548 18861 16058 13901 12201 10834 9715 8786 8003 7338 Zonal cavity method Effective floor reflectance = 20% Candela Plot 105 120 135 150 180 150 135 120 105 90 Zonal Lumens and Percentages 90 Luminance Summary (Candela/M 2 ) 2500 75 ZONE LUMENS % LUMINAIRE ANGLE 0-DEG 45-DEG 90-DEG 0-40 0-60 0-90 90-180 12501 20038 25610 0 48.8 78.2 100.0 0.0 0 45 55 65 75 85 21750 19310 17710 15830 12100 3998 21750 11410 10860 10720 14100 15670 21750 11580 11530 13680 17620 17080 SC: 0-180: 1.23 90-270: 1.23 60 75 5000 60 7500 45 45 10000 12500 30 15 0 15 0 Deg. Plane FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11202015 REV E (800) 523-3602 • www.simkar.com 30 90 Deg. Plane Technical Specifications Aisle Footcandle Estimator VALUES ARE APPROXIMATE AND ARE FOR REFERENCE ONLY. Height RG2454MRHEU1 MR Reflector RG2654MRHEU1 RG2432MREU1 RG2632MREU1 30" Vertical fc 30" Vertical fc 30" Vertical fc 30" Vertical fc 20' 28 13 37 18 11 6 17 9 30' 19 10 25 14 8 5 11 7 40' 14 9 19 12 6 4 8 5 50' 11 7 15 9 4 3 7 5 Horizontal footcandle values 30" AFF. Vertial footcandles are averages. 12’ wide Aisles with fixtures 25’ on center. Consult a lighting engineer to meet specific requirements. Open Area Horizontal Footcandle Estimator VALUES ARE APPROXIMATE AND ARE FOR REFERENCE ONLY. WR Reflector Height RG2454WRHEU1 RG2654WRHEU1 RG2432WREU1 RG2632WREU1 20' 24 36 13 19 30' 23 34 12 18 40' 21 32 12 17 50' 20 30 11 16 250’ x 250’ area; fixtures spaced 25' on center. Values 30” AFF. Consult a lighting engineer to meet specific requirements. FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 11202015 REV E (800) 523-3602 • www.simkar.com