Datasheet ENG

advertisement
PH1 Range - PULL HANDLE CALL POINT
Exd, Weatherproof
Features
ᔢ Zone 1 and Zone 2 use.
ᔢ Ex d IIC T6 Gb
ᔢ Ex tb IIIC T85ºC Db
ᔢ IECEx certified Gb, Db
ᔢ ATEX certified Ex II 2 GD
ᔢ IP66 & 67
ᔢ Certified temperature: -55ºC to +70ºC
ᔢ Corrosion free GRP construction
ᔢ Optional in line, end of line resistors and diodes
ᔢ Retained stainless steel cover screws
Introduction
The PH1 double action pull handle call point has been designed for use
in flammable atmospheres and harsh environmental conditions. The GRP
enclosure is suitable for use offshore or onshore where light weight
combined with a high level of corrosion resistance is required.
Cooper MEDC Limited,
Colliery Road,
Pinxton, Nottingham
NG16 6JF, UK.
Cooper MEDC (USA)
3413 North Sam Houston Parkway West
Suite 212
Houston, TX 77086, USA
Sales Enq. UK: +44 (0)1773 864 100 Sales Enq. USA: +1 (713) 937- 9772 E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com
6DS130/A
Sales: Malux Finland Oy, P.O.Box 69, FI-06151 Porvoo, Phone +358 19 574 5700, Fax +358 19 574 5750, info@malux.fi, www.malux.fi
Specification
Certification:
Certified to IEC60079-0, IEC60079-1 and IEC60079-31
Certified to EN60079-0, EN60079-1 and EN60079-31
IECEx Cert. No. IECEx ITS 11.0021X
Atex Cert. No. ITS11ATEX17308X Ex II 2 GD
Ex d IIC T6 Gb, Ex tb IIIC T85ºC Db
Material:
Body/covers/handles:- GRP (glass reinforced polyester)
Fixings:- Stainless steel grade 316
Finish:
Cover:- natural red, Body:- natural black.
Handles:- natural white.
Cover may be painted to customer's requirements.
Voltage:
0-50Vdc, 0-254Vac.
Switch Rating:
1 or 2 c/o switches, 254V, 3A max.
Weight:
Gross weight 3.2Kg. Net weight 2.6Kg
Certified Temp:
-55°C to +70°C.
Ingress Protection:
IP66 & 67.
Entries:
Up to 2 x M20 or M25, up to 2 x 1/2” or 3/4” NPT.
Terminals:
6 x 2.5mm2 as standard. Contact Cooper MEDC for options.
Earth Continuity:
Earth continuity is provided by internal plate.
Labels:
'Burning house' label fitted as standard on red units.
Blank label fitted as standard on all other colour units.
Tag & Duty label options, worded to customers requirements.
Addr. module:
Consult Cooper MEDC for options.
Resistors:
Various configurations available, 470 Ohms minimum.
Diodes:
Various configurations available.
SINGLE SWITCH
DOUBLE SWITCH
SINGLE SWITCH
DOUBLE SWITCH
SINGLE SWITCH
DOUBLE SWITCH
Standard wiring switch only
Standard wiring c/w EOL resistor
R1 - EOL Resitor
Standard wiring c/w series resistor or
series & EOL resistor
R1 - Series Resitor
R2 - EOL Resitor (if fitted)
ALL DIMENSIONS IN MILLIMETRES
Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each
component into the appropriate box.
Model
Entries
Certification
Switches
Features
Finish
PH1
Certification
ATEX
IECEx
Code
B
J
Entries
M20
M25
1/2" NPT
3/4" NPT
Code
*B
*C
*M
*N
Switches
Single changeover
Double changeover
* Prefix entry size with entry position
(see diagram above). E.g. 4B6B.
Maximum 2 Entries
Code
S
D
Features
None
Series resistor
EOL resistor
Diode
Tag label
Duty label
Code
N
G*
H*
E*
T*
D*
Finish
Natural Red
Special
Code
R
S*
* Please specify
* Please specify
NOTE: the units can be internally wired to suit customers specifications. Please discuss your requirements with us.
All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.
Sales: Malux Finland Oy, P.O.Box 69, FI-06151 Porvoo, Phone +358 19 574 5700, Fax +358 19 574 5750, info@malux.fi, www.malux.fi
02/12
Download