Key comparison CCM.V-K1.B2 MEASURAND : NOMINAL VALUE : xi: ui: Lab i Kinematic viscosity 400 mm2/s at 40 °C result of measurement carried out by laboratory i relative standard uncertainty of x i xi ui / (mm /s) / 10 Date of measurement 393.230 394.208 394.209 393.690 394.389 394.400 394.160 393.320 395.137 394.010 394.510 394.331 396.929 394.050 394.768 394.950 2.00 1.40 0.73 0.60 0.39 1.75 0.74 1.21 1.32 0.80 1.51 1.26 2.40 2.40 20.90 1.26 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 May - July 2002 2 BNM-LNE CANNON GUM CNR-IMGC NMIJ NMi-VSL PTB SMU UME VNIIM BEV CENAM INM(RO) IPQ NIS NPLI -3 Laboratories maintaining an independent scale The BIPM key comparison database, June 2008 1/4 Key comparison COOMET.M.V-K1 MEASURAND : NOMINAL VALUE : x i COO: u i COO: Kinematic viscosity 100 mm2/s at 20 °C result of measurement carried out by laboratory i relative standard uncertainty of x i COO Lab i x i COO / (mm /s) / 10 Date of measurement 91.482 91.474 91.723 91.681 2.7 1.1 1.6 1.2 2005 2005 2005 2005 2 BelGIM UkrCSM BIM VNIIM u i COO -3 In order to link the results of key comparison COOMET.M.V-K1, taken at nominal value 100 mm 2/s, to those of key comparison CCM.V-K1.B2, taken at nominal value 400 mm2/s, COOMET data were evaluated for a kinematic viscosity of 400 mm 2/s, according to the procedure described in Section 4 of the COOMET.M.V-K1 Final Report, which is based of the common participation of VNIIM in both key comparisons. The resulting values are given in the following table for the three laboratories which participated in COOMET.M.V-K1 only. MEASURAND : NOMINAL VALUE : xi: ui: Lab i Kinematic viscosity 400 mm2/s at 40 °C result of measurement carried out by laboratory i (evaluated for the CCM.V-K1.B2 nominal value) relative standard uncertainty of x i xi ui / (mm /s) / 10 Date of measurement 393.155 393.121 394.191 2.8 1.4 1.8 2005 2005 2005 2 BelGIM UkrCSM BIM The BIPM key comparison database, June 2008 -3 2/4 Key comparison CCM.V-K1.B2 MEASURAND : Kinematic viscosity 2 NOMINAL VALUE : 400 mm /s at 40 °C The key comparison reference value, x R, is calculated as the arithmetic mean of the results of those laboratories which maintain an independent scale. Its standard uncertainty, u R, is calculated as the uncertainty of the arithmetic mean. x R = 394.075 mm2/s and u R = 0.177 mm2/s. The degree of equivalence of each laboratory with respect to the key comparison reference value is given by a pair of terms: D i = x i - x R and U i , its expanded uncertainty (k = 2), both expressed in (mm2/s). The derivation of U i may be found in the CCM.V-K1 Final Report. The degree of equivalence between two laboratories i and j is given by a pair of terms: D ij = x i - x j and U ij , its expanded uncertainty (k = 2), both expressed in (mm2/s), U ij = 2x R(u i 2 + u j 2)1/2. The full matrix of equivalence is not computed here. The degrees of equivalence of the three laboratories which participated in key comparison COOMET.M.V-K1 for nominal value 100 mm 2/s, relative to the CCM.V-K1.B2 key comparison reference value are deduced from the results evaluated for 400 mm 2/s as explained in Section 4 of the COOMET.M.V-K1 Final Report. Lab i Di Ui Lab i 2 BNM-LNE CANNON GUM CNR-IMGC NMIJ NMi-VSL PTB SMU UME VNIIM / (mm /s) 1.5 -0.8 1.0 0.1 0.6 0.1 0.5 -0.4 0.4 0.3 1.3 0.3 0.6 0.1 0.9 -0.8 1.0 1.1 0.6 -0.1 BEV CENAM INM(RO) IPQ NIS NPLI BelGIM UkrCSM BIM Di / (mm 0.4 0.3 2.9 0.0 0.7 0.9 -0.92 -0.95 0.12 Ui 2 /s) 1.2 1.0 1.9 1.9 16.5 1.0 2.2 1.0 1.4 CCM.V-K1.B2 participants maintaining an independent scale participants in COOMET.M.V-K1 only The BIPM key comparison database, June 2008 3/4 CCM.V-K1.B2 and COOMET.M.V-K1 - Kinematic viscosity of Liquid B2 (400 mm2/s) Degrees of equivalence D i and expanded uncertainty U i (k = 2) 5.0 4.0 2 Di = (xi - x R) / (mm /s) 3.0 2.0 1.0 0.0 -1.0 -2.0 -3.0 U NIS = 16.5 mm 2/s -4.0 BIM UkrCSM BelGIM NPLI NIS IPQ INM(RO) CENAM BEV VNIIM UME SMU PTB NMi-VSL NMIJ CNR-IMGC GUM CANNON BNM-LNE -5.0 Red diamonds: CCM.V-K1.B2 participants maintaining an independent scale Open red circles: other CCM.V-K1.B2 participants Green triangles: participants in COOMET.M.V-K1 only The BIPM key comparison database, June 2008 4/4