Part Number C156.065 Wiring Instructions ™ SC1-Gen2 Control by Draper Caution Electrical Specifications ➀ Make sure power is disconnected before installing controls. ➁ To Reduce the Risk Of Fire, Electric Shock, Or Injury To Persons, Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards. ➂ To reduce the risk of fire and electric shock, install SC1-Gen2 only with listed window shade operator(s) rated maximum 9.8 amps at 115VAC each. ➃ SC1-Gen2 is a line voltage control, designed to operate one motor. Activation by low voltage input commands. If you want to switch two or more motors, ISO relays must be installed in the circuit. ➄ SC1-Gen2 is electrically “hot” on the back of the circuit board. INS-SC1 (Draper Part Number C199.004) insulation board is provided. Input: E317985 Data: +12VDC BUS Commands 3SMW Low Voltage: Dry Contact—0v AC Window Shade Control Line Voltage: 115VAC 50Hz Output: ½ HP, 115VAC 9.8 FLA. Signal Output is Class 2. Dimensions: 2½" W x 2¾" L x 7/8" H. One SC1-Gen2 fits in a deep single gang J-Box. Please Note: This device has not been evaluated for reliability to the Standard for Tests for Safety-Related Controls Employing Solid-State Devices, UL 991 and therefore not considered suitable for entrapment protection. Please Note: For low voltage wiring requirements, Draper recommends consulting with a professional low voltage electrical contractor. It is very important that shielded and stranded CAT 5 cable be used to prevent any electrical interference. Wiring Instructions for Controlling One Shade with One SC1 To 115VAC Motor 11 Ho 5VAC Ne t (bla utr ck al ( ) wh ite ) Data BUS "Aux" Port Dry input terminals. This can be any Single Pole, Double Throw switch (Torque dry input screw terminals to 3 Lb-In. Inserting wire into spring terminal ➀ Open spring terminal by inserting screwdriver into upper opening. ➁ Insert wire into lower opening. ➂ Remove screwdriver. Ground Note: Motor red and black wires will need to “flip” if one motor is right hand and the other is left hand. Motor Neutral -white Black - Up Red-Down Data BUS "Eye" Port Fabric unrolling from back of roller (standard) Please Note: When connecting data "BUS," never link an "Eye" port to another "Eye" port. You may link your BUS from "Eye" to "Aux" or "Aux" to "Aux." All BUS command input devices must connect to an "Eye" port in order to power the input device. Right hand motor (Standard) Black—Up Red—Down Wiring Instructions for Controlling Multiple Shades with One SC1 Please Note: This configuration will limit SC1-Gen2 functions. Left hand motor en To 115VAC Motor 1 Gre ISO PU ISO IN PU T Note: Motor red and black wires will need to "flip" if one motor is right hand and the other is left hand. Right hand motor (Standard) Red—Up Black—Down Interior side Left hand motor IN Data BUS "Eye" Port Fabric unrolling from front of roller (reverse roll) Earth Ground To Additional Motor Green Wire Green T Motor Neutral -White Black - Up Red-Down Black—Down Red—Up To 115VAC Motor 2 Neu tral U Dow p n Dry input terminals. This can be any Single Pole, Double Throw switch (Torque dry input screw terminals to 3 Lb-In). Neu tral U Dow p n SC1 11 Ho 5VAC Ne t (bla utra ck) l (w hite ) Data BUS "Aux" Port Interior side To additional ISOs Red—Down Black—Up All connection wires must conform to the motor manufacturer’s recommendation and prevailing electrical codes. Use appropriate Class 2 wiring as determined by location of use or install as required by Article 725 of the NEC and local codes. USE COPPER CONDUCTORS ONLY rated at 75° C or higher. Please Note: All input devices (low voltage LED switches, IR eye, RF receiver) which connect to the Eye jack must be connected using electrically straight 6-conductor modular cable (RJ25). This means colors do not cross over: blue leads to blue, green to green, etc. (see diagram below) PIN 6 CORRECT Tab facing away (down) BLUE YELLOW GREEN RED BLACK WHITE INCORRECT PIN 1 WHITE BLACK RED GREEN YELLOW BLUE WHITE BLACK RED GREEN YELLOW BLUE PIN 6 Tab facing away (down) PIN 1 Form SC1-Gen2_WD11 PIN 1 Tab facing away (down) PIN 1 WHITE BLACK RED GREEN YELLOW BLUE Tab facing away (down) PIN 6 Six-Pin Layout ® Copyright ©2011 Draper Inc. PIN 6 COLOR WHITE BLA L CK RED GREEN YELLOW BLUE Printed in U.S.A. PIN # 1 2 3 4 5 6 FUNCTION R CLOCK RQ COMMON +5VDC 5VDC R DA RQ D TA RP DA D TA +12VDC 12VDC If you encounter any difficulties installing/wiring your IntelliFlex control, call your dealer or Draper, Inc., Spiceland, Ind., (765) 987-7999; or fax (765) 987-7142. Aux Port Aux Port Eye Port To Motor Neutral Red (Dir) Black (Dir) Eye Port Dry Aux Contacts Port Eye Port Data cable from Aux Port to Eye port of next SPGC4 To Motor Neutral Red (Dir) Black (Dir) Dry Contacts Aux Port (765) 987-7999 www.draperinc.com Dry Contacts To Eye Port Neutral AC (115/VAC) To Bla Moto R e ck r Ne d (D (Dir ut ir) ) ral To Switch, splitter or other input device To Bla Moto R e ck r Ne d (D (Dir ut ir) ) ral Page 2 of 2 ™ SC1-Gen2 Control by Draper