3000 Series - CyberSelect

advertisement
GRAFIK Eye 3000 Series – Designing a System
®
Step 1
Determine number
of zones and sources
Sources
Incandescent
Magnetic Low-Voltage
Electronic Low-Voltage*
Fluorescent*
Neon/Cold Cathode
Lutron Tu-Wire™
High-Intensity Discharge*
(non-dim only)
* Interface required to dim.
Consult product pages for specifics.
Choose the zones in your space.
A zone is a light or group of lights controlled by the same switch or dimmer. GRAFIK Eye Controls
have the ability to dim most popular sources and to control several zones at one time from one button
press. Important factors to consider when creating zones are flexibility of control and aesthetics.
Conference Room Reflected Ceiling Plan
ZONE 2
Design Tips
For information on load
side emergency transfer
with GRAFIK Eye 3000
Series Control Units,
see Application Notes
pg. 92.
ZONE 3
ZONE 4
www.lutron.com
Wa
tts/
Vol
t-a
mp
s
Fixt
ure
s
No.
of
Fixt
ure
Loa
d
Key:
1
2
3
4
Podium
Table
Perimeter
Accent
120
120
120
120
N
N
N
N
INC
ELV
INC
FLD
75
50
50
26
1
18
13
16
Note: Blank Load schedules are available. See pg. 100.
* Includes transformer losses
10
Typ
e
Loa
d
Typ
e
Fee
d
Vol
tag
e
(N,
E)
Calculate wattage and record load type for each zone.
Des
crip
tion
Transformer loss:
Ballasts and transformers
draw additional load
beyond the lamp wattage.
For example, electronic
low-voltage transformers
typically draw an
additional 10% of the
actual lamp wattage.
ZONE 1
Zon
e
Dimming Ballasts are
required to dim fluorescent
sources. For information
on Lutron Fluorescent
Dimming Ballasts, see
pgs. 96-99.
Lutron World Headquarters: 1.610.282.3800
75
990*
650
416
N
E
INC
ELV
Normal
Emergency
Incandescent
Electronic
Low-Voltage
FLD Lutron Fluorescent
Dimming
Step 2
Select GRAFIK Eye 3000
Series Control Units
®
Design Tip
If your space requires more
than six zones, up to eight
GRAFIK Eye 3000 Series
Control Units can be linked
together for control of up
to 48 zones in one system.
Choose the appropriate Control Unit.
This project requires four zones, therefore a GRX-3104 is selected. Choose a 3500 Model Control
Unit if programming the system from a PC and saving light levels at 1% increments is required.
Typically, a separate GRAFIK Eye Control Unit should be included for each distinct room/space
in a project.
See ordering pgs. 14–16.
For example, for 10 zones:
4-zone
+
Control Unit
6-zone
Control Unit
= 10 total zones
Step 3
Select Load–
Appropriate Interfaces
Design Tips
Loads greater than the
GRAFIK Eye 3000 Series
Control Unit zone maximum?
For incandescent, magnetic
low-voltage, neon/cold
cathode, and Lutron Tu-Wire™
Fluorescent Dimming Ballasts,
use NGRX-PB to increase
zone wattage capability
(see ordering pg. 18).
For multiple load circuits per
zone, use Hi-Power 2•4•6™
(see ordering pg. 19).
Dimming electronic low
voltage loads? Use ELVI
(see ordering pg. 18).
Dimming Lutron Hi-lume®
or Eco-10™ (ECO-series)
Fluorescent Dimming
Ballasts? Use FDBI
(see ordering pg. 18).
If a project requires 277V
Lutron Hi-lume or Eco-10
(ECO-series) Fluorescent
Dimming Ballasts and the
rest of the loads are 120V,
a Hi-Power 2•4•6 must be
used for the 277V zone
(see ordering pg. 19).
Dimming 0-10V Fluorescent
Dimming Ballasts or switching
non-dim loads? Use GRX-TVI
(see ordering pg. 19).
Select Power Boosters/Interfaces for specific wattages/loads.
Specific zones require Power Boosters if load wattage exceeds maximum capacity per zone
(max capacity per zone found on Control Unit ordering pages 14–16). GRAFIK Eye 3000 Series
Controls Units can control incandescent, magnetic low-voltage, neon/cold-cathode, and Lutron
Tu-Wire™ fluorescent loads directly. When electronic low-voltage or fluorescent loads need to be
controlled, a load-specific Power Interface is required.
For this project, Zone 2 is an electronic low-voltage load. Therefore, an electronic low-voltage
interface is required. Zone 4 is a Hi-lume® fluorescent dimming zone; therefore, a Fluorescent
Dimming Ballast Interface is required.
See ordering pgs. 17–19.
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
11
GRAFIK Eye 3000 Series – Designing a System
®
1
2
3
4
Podium
Table
Perimeter
Accent
INC
ELV
INC
FLD
75
990
650
416
Boo
ster
/In
terf
ace
Act
ual
L
o
GR
AFI ad on
Wa K Eye
tts/ zon
Vol e
t-a
mp
s
Wa
tts/
Vol
t-a
mp
s
Loa
d
If total load is larger than
maximum capacity for the
Control Unit, add additional
Power Boosters/Interfaces
to higher wattage zones
and recalculate total load.
Repeat Step 3 until total
load is less than or equal
to maximum capacity for
the Control Unit selected.
Zon
e
Design Tip
Typ
e
Calculate the total wattage for all zones to verify
that total wattage does not exceed total unit capacity.
Des
crip
tion
Step 3 (cont.)
Select Load–
Appropriate Interface
not required
ELVI
not required
FDBI
75
40*
650
40*
805
TOTAL LOAD
Note: Blank Load schedules are available. See pg. 100.
Compare total load
to maximum capacity
for Control Unit. For
this example, total
load is 805 W/VA.
Maximum Capacity
for a GRX-3104 at
120V is 2000W/VA;
therefore, no
additional boosting
is needed.
Key:
N
E
INC
ELV
Normal
Emergency
Incandescent
Electronic
Low-Voltage
FLD Lutron Fluorescent
Dimming
* When a Power
Booster/Interface is
added, the zone
load on the GRAFIK
Eye Control Unit for
that zone becomes
40W/VA.
Page example above is taken from GRAFIK Eye 3000 Series Control Units ordering pg. 16.
Add Wallstations and Control Interfaces to achieve design strategies.
Step 4
Select Design
Strategies
Design Tip
Up to three Wallstations/
Control Interfaces can be
powered from a single
GRAFIK Eye 3000 Series
Control Unit. If additional
Wallstations/Control
Interfaces (up to 16 total)
are needed, a 12VDC power
supply should be added.
For Lutron GRX-12VDC,
see ordering pg. 90.
For this project, use an
Entrance Control, NTGRX-2B-SL
(see pg. 21) at the door and
a Scene Control NTGRX-4S
(see pg. 22), at the lectern.
Integrate to the audiovisual
system for control from a
touchscreen with a GRX-RS232
(see pg. 31).
Page examples above are taken from GRAFIK Systems Design Strategies pgs. 8, 9.
12
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
Step 5
Support the Design
Design Tips
Lutron’s Designer™ software allows faster system
design by automatically
assigning the types of Power
Boosters/Interfaces required
from zone load type and
wattage information. The
software generates a
complete bill of material,
including Wallstations and
Control Interfaces, and a
one-line diagram that can
be saved and exported as
a .dxf file. GRAFIK Eye®
Designer® Software is available at www.lutron.com.
Support the design through one-line diagrams
and written product specifications.
Zone 1, 75W of INC
NOTES:
2 #12 (2.5mm2)
NGRX-ELVI
Zone 2, 990W of ELV
ELVI
Zone 3, 650W of INC
2 Twisted pair #18
(1.0mm 2)
NGRX-FDBI
Zone 4, 416W of FLD
FDBI
3 #12 (2.5mm2)
Input Power
GRX-3104-T-WH
Address A1
4-Zone Control Unit
Select Scenes 1-4 & off
NTGRX-2B-SL
NTGRX-4S
2-Button Control with LED
Select Scene 1 & off
Entrance Control
Scene Selection Control
Select Scenes 1-4 & off
Lectern Scene Control
GRX-RS232
RS232 Interface
Integrate to A/V system
Complete product
specifications are available
at www.lutron.com.
Finished products/System layout
Conference Room
Sample Products
F
A. GRAFIK Eye 3000 Series
Control Unit
B. Scene Selection
Wallstation for multiple
control locations
C. Entrance Control
at doorway
G
E
D
C
A
B
D. Fluorescent Dimming
Ballasts Interface
E. Lutron Hi-Lume® Fluorescent
Dimming Ballast
F. RS232 Interface for
integration to A/V system
G. Electronic Low-Voltage
Interface
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
13
GRAFIK Eye 3000 Series
3000 Series Control Units
Architectural Grade
Cover (shown open)
• For single room or multiple room applications
• 2-, 3-, 4-, or 6-zone GRAFIK Eye Control Units available
• A GRAFIK Eye Control Unit is fed from a single feed
• Up to eight GRAFIK Eye Control Units can be linked for up to 48 zones
• Four scenes per GRAFIK Eye Control Unit, expandable up to 16 scenes
• Up to 16 total Wallstations and Control Interfaces can be added for a total of 24
control points
• Built-in Infrared Receiver/Optional Wireless Remote Control
• User-defined lockout options
• Single zone capacity can be increased with Power Boosters/Interfaces
• Variable Fade Time: (0-59 seconds and 1-60 minutes set by end user)
Compatible Lutron Products
Zone
Base
Matching Accessories
Infrared Receiver
Scene Selection Buttons
Control Unit
Remote
Controls pg.27
Wallstation
Controls pg.20
Power Boosters/
Interfaces pg.17
Receptacles
pg.91
Cable and
Phone Jacks pg.91
GRAFIK Eye 3000
SYSTEM MAP
Control Units
• Use the map at right to identify system
component being reviewed in each section
• Mini map is duplicated at the bottom of
each two-page spread for easy reference
Sources
Incandescent
Magnetic Low-Voltage
Electronic Low-Voltage*
Fluorescent*
Neon/Cold Cathode
Lutron Tu-Wire™
High-Intensity Discharge*
(non-dim only)
* Interface required to dim.
Consult product pages for specifics.
SPECIAL DESIGN
C O N S I D E R AT I O N S
Standards listed below apply to one or more
products in the Grafik Eye product line.
Consult factory for specific information.
LUTRON
Quality Systems
registered
to ISO 9001
• GRAFIK Eye 3500 Model Control Units can be programmed at the Control Unit
or from a PC and offer the precision of setting light levels in 1% increments
• Load Types:
- Directly: incandescent, magnetic low-voltage, neon/cold cathode,
and Lutron Tu-Wire™ Fluorescent Dimming Ballast
- Through Power Interfaces: fluorescent and electronic low-voltage
- For control of non-dim motor loads, see Application Notes, pg. 93
• Mounting:
- Fits standard US wallboxes, 3.50”(89mm) deep strongly recommended, 2.75”(69.9mm) minimum
- For more information, see Application Notes, pg. 92
• Wallstations and Control Interfaces:
Maximum: 16 (Class 2/PELV)
• Max. Load Ratings (Per unit load should not exceed max. capacity listed on ordering pages)
Per Zone
Max. Load
120V, 50/60Hz
220-240V, 50/60Hz
230V, 50/60Hz
100V, 50/60Hz
14
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
800W/VA
1200W/VA (non CE)
800W/VA (CE)
600W/VA
3000 Series
CONTROL UNITS
Product
Max. Capacity1
Model
Color
Suffix
2-ZONE CONTROL UNIT
Ordering Example
Incandescent, Magnetic Low-Voltage,
Neon/Cold Cathode, Lutron Tu-Wire™
Fluorescent Dimming Ballast
120V
3100
1200W/VA
35003
1200W/VA
GRX-3102-T- AU-WH
add cover choice
and color/finish suffix
to model #
GRX-3102-_
GRX-3502-_
COVER OPTIONS
Opaque
A
Cover and base will match
Dimensions
120V, 220-240V, 100V,
W: 5.56” (141mm)
H: 4.56” (116mm)
D: 2.25” (57mm)2
Wallbox Size: two-gang, 3.50” (89mm) deep
230V
W: 8.94” (227mm)
H: 4.56” (116mm)
D: 2.25” (57mm) 2
Wallbox Size: four-gang, 3.50” (89mm) deep
Translucent Black T
220-240V (non CE)
3100
35003
1600W/VA
1600W/VA
GRX-3102-_-AU-_
GRX-3502-_-AU-_
230V (CE)
3100
35003
1600W/VA
1600W/VA
GRX-3102-_-CE-_
GRX-3502-_-CE-_
100V
3100
35003
1000W/VA
1000W/VA
GRX-3102-_-JA-_
GRX-3502-_-JA-_
Electronic Low-Voltage, Fluorescent
Electronic low-voltage sources and Lutron Hi-lume® and Eco-10™ (ECO-Series)
fluorescent ballasts require interfaces. Interface is not required for Lutron’s
Tu-Wire Fluorescent Dimming Ballast.For more information, see pgs. 18–19.
W: 7.25” (184mm)
H: 4.56” (116mm)
D: 2.25” (57mm) 2
Wallbox Size: three-gang, 3.50” (89mm) deep
230V
W: 8.94” (227mm)
H: 4.56” (116mm)
D: 2.25” (57mm)2
Incandescent, Magnetic Low-Voltage,
Neon/Cold Cathode, Lutron Tu-Wire
Fluorescent Dimming Ballast
120V
3100
1500W/VA
35003
1500W/VA
GRX-3103-_
GRX-3503-_
220-240V (non CE)
3100
3500 3
2400W/VA
2400W/VA
GRX-3103-_-AU-_
GRX-3503-_-AU-_
230V (CE)
3100
35003
2300W/VA
2300W/VA
GRX-3103-_-CE-_
GRX-3503-_-CE-_
100V
3100
3500 3
1250W/VA
1250W/VA
GRX-3103-_-JA-_
GRX-3503-_-JA-_
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Gloss Finishes
(Cover choice: A only)
Consult factory
for pricing.
Ships in 4-6 weeks.
White
GWH
Light Almond
GLA
Almond
GAL
Ivory
GIV
Metal Finishes
Wallbox Size: four-gang, 3.50” (89mm) deep
Electronic Low-Voltage, Fluorescent
Electronic low-voltage sources and Lutron Hi-lume and Eco-10 (ECO-Series)
fluorescent ballasts require interfaces. Interface is not required for Lutron’s
Tu-Wire Fluorescent Dimming Ballast. For more information, see pgs. 18–19.
Footnotes, pg. 15
1 Maximum capacity shown is for Control Unit.
Per Zone
Maximum Capacity
120V,50/60Hz
800W/VA
220-240V,50/60Hz
1200W/VA (non CE)
230V,50/60Hz
800W/VA (CE)
100V,50/60Hz
600W/VA
2 Depth includes wallplate and backbox. Wallplate depth is 0.35”(9mm).
3 3500 Series Control Units can be programmed from a PC and offer
the precision of setting light levels in 1% increments.
(Cover choice:T only)
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Control Units
120V, 220-240V, 100V,
BASE COLORS
Matte Finishes
3-ZONE CONTROL UNIT
Dimensions
Black cover and
your choice of base color
GRAFIK Eye 3000 Series
Source
Control Units
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
• See pgs. 108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
15
GRAFIK Eye 3000 Series
3000 Series
Source
CONTROL UNITS
Dimensions
120V, 220-240V, 230V, 100V
W: 8.94” (227mm)
H: 4.56” (116mm)
D: 2.25” (57mm) 2
Wallbox Size: four-gang, 3.50”(89mm) deep
Control Units
Product
Max. Capacity1
Model 4
Ordering Example
Incandescent, Magnetic Low-Voltage,
Neon/Cold Cathode, Lutron Tu-Wire™
Fluorescent Dimming Ballast
120V
3100
2000W/VA
35003
2000W/VA
GRX-3104-T- AU-WH
GRX-3104-_
GRX-3504-_
220-240V (non CE)
3100
35003
3000W/VA
3000W/VA
GRX-3104-_-AU-_
GRX-3504-_-AU-_
230V (CE)
3100
3500 3
2300W/VA
2300W/VA
GRX-3104-_-CE-_
GRX-3504-_-CE-_
100V
3100
3500 3
1600W/VA
1600W/VA
GRX-3104-_-JA-_
GRX-3504-_-JA-_
add cover choice
and color/finish suffix
to model #
Control Units
W: 8.94” (227mm)
H: 4.56” (116mm)
D: 2.25” (57mm) 2
Wallbox Size: four-gang, 3.50”(89mm) deep
Incandescent, Magnetic Low-Voltage,
Neon/Cold Cathode, Lutron Tu-Wire
Fluorescent Dimming Ballast
120V
3100
2000W/VA
35003
2000W/VA
Black cover and
your choice of base color
BASE COLORS
GRX-3106-_
GRX-3506-_
220-240V (non CE)
3100
35003
3000W/VA
3000W/VA
GRX-3106-_-AU-_
GRX-3506-_-AU-_
230V (CE)
3100
35003
2300W/VA
2300W/VA
GRX-3106-_-CE-_
GRX-3506-_-CE-_
100V
3100
35003
1600W/VA
1600W/VA
GRX-3106-_-JA-_
GRX-3506-_-JA-_
Footnotes, pg. 16
Lutron World Headquarters: 1.610.282.3800
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Gloss Finishes
(Cover choice: A only)
Consult factory
for pricing.
Ships in 4-6 weeks.
White
GWH
Light Almond
GLA
Almond
GAL
Ivory
GIV
Metal Finishes
1 Maximum capacity shown is for Control Unit.
Maximum Capacity
Per Zone
120V,50/60Hz
800W/VA
220-240V,50/60Hz
1200W/VA (non CE)
230V,50/60Hz
800W/VA (CE)
100V,50/60Hz
600W/VA
2 Depth includes wallplate and backbox. Wallplate depth is 0.35”(9mm).
3 3500 Series Control Units can be programmed from a PC and offer
the precision of setting light levels in 1% increments.
4 Dual feed models are available for 120V. Consult Lutron for details.
www.lutron.com
Cover and base will match
Matte Finishes
Electronic Low-Voltage, Fluorescent
Electronic low-voltage sources and Lutron Hi-lume and Eco-10 (ECO-Series)
fluorescent ballasts require interfaces. Interface is not required for Lutron’s
Tu-Wire Fluorescent Dimming Ballast. For more information, see pgs. 18–19.
16
COVER OPTIONS
Opaque
A
Translucent Black T
6-ZONE CONTROL UNIT
120V, 220-240V, 230V, 100V
Suffix
4-ZONE CONTROL UNIT
Electronic Low-Voltage, Fluorescent
Electronic low-voltage sources and Lutron Hi-lume® and Eco-10™ (ECO-Series)
fluorescent ballasts require interfaces. Interface is not required for Lutron’s
Tu-Wire Fluorescent Dimming Ballast. For more information, see pgs. 18–19.
Dimensions
Color
(Cover choice:T only)
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
• See pgs. 108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
3000 Series
Power Boosters/Interfaces
GRAFIK Eye 3000 Series
Architectural Grade
• Increases single zone load capacity
• Models for single zone interface to fluorescent
and electronic low-voltage loads
Hi-Power 2•4•6™
Ten Volt Interface
Compatible
Lutron Products
Dimming Ballasts pgs.96–99
Power Booster/Interface
GRAFIK Eye 3000
SYSTEM MAP
• Use the map at right to identify system
component being reviewed in each section
Power Boosters/Interfaces
• Mini map is duplicated at the bottom of
each two-page spread for easy reference
Sources
Incandescent
Magnetic Low-Voltage
Electronic Low-Voltage*
Fluorescent*
Neon/Cold Cathode
Lutron Tu-Wire™
High-Intensity Discharge*
(non-dim only)
* Interface required to dim.
Consult product pages for specifics.
SPECIAL DESIGN
C O N S I D E R AT I O N S
Standards listed below apply to one or more
products in the Grafik Eye product line.
Consult factory for specific information.
LUTRON
Quality Systems
registered
to ISO 9001
All Power Booster/Interfaces
• All voltages indicated are phase-to-neutral
• Power Boosters/Interfaces will operate on 50 or 60Hz power
• Power Boosters/Interfaces are not plenum rated
• When mounting several units in vertical layout, allow 4.5” (114mm) between
wallplates (see Application Notes pg. 92)
• Indoor use only
• Power Booster/Interfaces must be mounted within 7° of true vertical
• Power Boosters/Interfaces generate heat; mount only where ambient temperature
will be 0-40°C (32°-104°F) with a non-condensing relative humidity <90%
• Common neutrals are not permitted; run separate neutrals for each load circuit
Hi-Power 2•4•6 Modules only
• Modules generate audible noise; mount where acceptable
• Do not use generator-supplied power
• Up to five modules can be daisy chained for greater capacity
• 277V for fluorescent and magnetic low-voltage loads only
UP
-7˚
+7˚
Mount
Booster/Interface
Vertically
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
17
GRAFIK Eye 3000 Series
3000 Series
Source
Power Boosters/Interfaces
Product1
Max. Capacity
Model
POWER BOOSTER 2
Ordering Example
• Increases single zone load capacity
• Controls incandescent, magnetic low-voltage, neon/cold cathode loads,
and Lutron’s Tu-Wire™ Fluorescent Dimming Ballasts4
• Can switch (non-dim) all of the sources mentioned above
• Up to two Power Boosters per GRAFIK Eye zone
NGRX-PB- JA-WH
120V
1920W/VA
NGRX-PB-WH
Dimensions
100V
1600W/VA
NGRX-PB-JA-WH
W: 4.56” (116mm)
H: 4.56” (116mm)
D: 0.69” (18mm) 3
220-240V (non CE)
2400W/VA
NGRX-PB-AU-WH
230V (CE)
1200W/VA
(with Wallplate)
1840W/VA
(without Wallplate)
NGRX-PB-CE-WH
Wallbox Size: two-gang
ELECTRONIC LOW-VOLTAGE INTERFACE 2
Power Boosters/Interfaces
• Allows dimming of electronic transformer-supplied low-voltage lighting
requiring reverse phase-control dimming
• Up to two interfaces per GRAFIK Eye zone
120V
1000W
ELVI-1000
100V
1000W
NGRX-ELVI-JA-WH
Dimensions
220-240V (non CE)
1200W
NGRX-ELVI-AU-WH
W: 4.56” (116mm)
H: 4.56” (116mm)
D: 0.69” (18mm)3
Wallbox Size: two-gang
230V (CE)
1200W
NGRX-ELVI-CE-WH
LUTRON FLUORESCENT DIMMING BALLAST INTERFACE 2
• Allows dimming of Lutron Hi-Lume® and Eco-10™4 (ECO-Series)
line voltage control Electronic Dimming Ballasts only
• Not to be used for switching
• Up to two interfaces per GRAFIK Eye zone
Dimensions
W: 4.56” (116mm)
H: 4.56” (116mm)
D: 0.69” (18mm) 3
120V
16A
GRX-FDBI-16A-120
100V
16A
NGRX-FDBI-JA-WH
220-240V (non CE)
10A
NGRX-FDBI-AU-WH
Wallbox Size: two-gang
Footnotes, pg. 18
1
2
3
4
18
www.lutron.com
All voltages indicated are phase-to-neutral.
Load circuit feed is phase independent of control circuit from dimmer.
Depth is from Wallplate to wall. Wallplate depth is 0.35”(9mm).
See Fluorescent ballasts,pgs.96–99,for lamp types and
ballast ordering information.
Lutron World Headquarters: 1.610.282.3800
Standard, ships in 48 hrs.
3000 Series
Dimensions
W: 6.10” (155mm)
H: 12.50” (318mm)
D: 3.30” (84mm)
Surface Mount
Product
Max. Capacity
Model
TEN VOLT INTERFACE
Ordering Example
• Allows dimming of Lutron Eco-10™
(TVE-Series) Electronic Dimming Ballasts1
• 0-10V control; sinks current only
• Up to five interfaces per zone
• Switching by relay (non-dim) ratings for all voltages
(0-10V control typically only used with fluorescent):
Incandescent–
16A
Low Voltage –
16A
Neon/Cold Cathode –
16A
Metal Halide –
16A
Fluorescent (capacitive) – 5A
Non-capacitive –
16A
120V–Motor –
1/4 hp
240V–Motor –
1/2 hp
GRX-TVI
Standard, ships in 48 hrs.
120V, 277V, 220-240V, 100V, 230V (CE)
(same model number for all voltages)
GRX-TVI
HI-POWER 2 DIMMING MODULE 3
HP-2
GRAFIK Eye 3000 Series
Source
Power Boosters/Interfaces
• Increases single GRAFIK Eye zone wattage capacity
to 2000 W/VA 2 (one circuit)
• 120V or 277V in one module 3; not for 100V, 230V, 220-240V
• Dims incandescent, magnetic low-voltage, electronic
low-voltage, fluorescent, neon/cold cathode sources
HI-POWER 4 DIMMING MODULE3
W: 10.38” (264mm)
H: 14.50” (368mm)
D: 5.75” (146mm)
wt: 15 lb (6.8kg)
Surface Mount
HI-POWER 6 DIMMING MODULE3
HP-6
• Increases single GRAFIK Eye zone wattage capacity
to 6000 W/VA2 (three circuits)
• 120V or 277V in one module 3; not for 100V, 230V, 220-240V
• Dims incandescent, magnetic low-voltage,
electronic low-voltage, fluorescent, neon/cold cathode sources
Footnotes, pg. 19
Power Boosters/Interfaces
Dimensions–HP 2,4,6
HP-4
• Increases single GRAFIK Eye zone wattage capacity
to 4000 W/VA2 (two circuits)
• 120V or 277V in one module 3; not for 100V, 230V, 220-240V
• Dims incandescent, magnetic low-voltage, electronic low-voltage,
fluorescent, neon/cold cathode sources
1 For more information on Lutron Eco-10 (TVE-Series) Electronic Dimming Ballasts,
see pgs. 96–99.
2 Load Capacity per Unit
Lamp Type
Dimmed
Switched
120V
Incandescent
16A,1920W
Magnetic Low-Voltage
16A,1920VA
Electronic Low-Voltage
16A,1920VA
Fluorescent–Lutron
16A,1920VA
Hi-lume®/Eco-10™ (ECO-Series)/Tu-Wire™
Fluorescent (non-capacitive) 3
Fluorescent (capacitive)3
Neon/Cold Cathode
16A,1920VA
Metal Halide
10A,1200W
10A,1200VA
10A,1200W
16A
16A
10A
10A,1200VA
10A,1200VA
277V
Magnetic Low-Voltage
16A,4432VA
Fluorescent–Lutron
16A,4432VA
Hi-lume/Eco-10 (ECO-Series)/Tu-Wire
3 Load circuit feed is phase independent of control circuit from dimmer.
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
19
GRAFIK Eye 3000 Series
3000 Series
Wallstations
Architectural Grade
• Provide additional control points throughout a space
• Up to 16 Wallstations and Control Interfaces can be added for a total
of 24 control points in one system
• Green status LEDs standard
• For design guidelines using Wallstations and Control Interfaces, see pgs. 8–9
• Use the following categories, found at the top of each appropriate ordering page,
to help in the selection of Wallstations and Control Interfaces
- Entrance Controls, pg. 21
- Scene Selectors, pg. 22
- Special Function Controls, pg. 25
- Infrared Controls, pg. 27
- Radio Frequency Controls, pg. 29
- Control Interfaces, pg. 30
Scene Selection Control (see pg.30)
2.75”w (70mm) x 4.56”h (116mm)
GRAFIK Eye 3000
SYSTEM MAP
• Use the map at right to identify system
component being reviewed in each section
Wallstations
• Mini map is duplicated at the bottom of
each two-page spread for easy reference
Sources
Incandescent
Magnetic Low-Voltage
Electronic Low-Voltage*
Fluorescent*
Neon/Cold Cathode
Lutron Tu-Wire™
High-Intensity Discharge*
(non-dim only)
* Interface required to dim.
Consult product pages for specifics.
SPECIAL DESIGN
C O N S I D E R AT I O N S
Standards listed below apply to one or more
products in the Grafik Eye product line.
Consult factory for specific information.
20
LUTRON
Quality Systems
registered
to ISO 9001
www.lutron.com
• Wallstation and Control Interface Maximums:
- Per System: 16 (Class 2/PELV)
- Three (Class 2/PELV) from each GRAFIK Eye Control Unit
without external power supply
- For Lutron Power Supply, GRX-12VDC, see pg. 90
• Wiring Specification & Maximums:
- Wire: two twisted pair #18AWG (1.0mm 2)
For Lutron non-plenum cable, order GRX-CBL-346S-500, pg. 90
- Distance: 2,000’ (610m)
For other cable distances, see GRAFIK Eye Application Notes
available at www.lutron.com
- Installation: Daisy chain (no home-run wiring)
• Power: 12VDC (From GRAFIK Eye 3000 Series Control Unit or GRX-12VDC)
• Configuration:
- Integral DIP switches determine function and can be configured in the field
• Mounting:
- Standard US wallbox unless otherwise noted
- No derating required when multiganged
Lutron World Headquarters: 1.610.282.3800
3000 Series
Product
Model
Color
Suffix
2-BUTTON ENTRANCE CONTROL
NTGRX-2B-SL-
Ordering Example
NTGRX-2B-SL-WH
• Turns lighting on (Scene 1) and off
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Stock engraving available; consult factory for
ordering information
• Control can be configured for one of several functions;
for other functions, see pgs. 22, 25
add color/finish suffix
to model #
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Metal Finishes
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.69” (43mm)1
Wallbox Size: single-gang
EUROPEAN-STYLE, 2-BUTTON
ENTRANCE CONTROL
EGRX-2B-SL
Dimensions
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm) 2
Wallbox Size: UK/German, single-gang
ENTRANCE CONTROL
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
• See pgs.108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
NTGRX-1S-
• Toggles between Scene 1 and off
• Line voltage control
• Up to 10 can be wired in parallel to one Control Unit
• Use for existing 3- and 4-way retrofits
• Not for use on two-zone GRAFIK Eye Control Units
• Does not count as one out of 16 maximum
Wallstations/Control Interfaces
Wallstations— Entrance Controls
• Turns lighting on (Scene 1) and off
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in
North America (add NA to P/N–EGRX-2B-SL-NA)
• Class 2/PELV Control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Control can be configured for one of several functions;
for other functions, see pgs. 23, 25
• In addition to wallplate engraving, control buttons can be engraved
GRAFIK Eye 3000 Series
CONTROLS
Wallstations — Entrance Controls
Function Reference
- Entrance Controls,
pg. 21
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.69” (43mm)1
Wallbox Size: single-gang
- Scene Selectors,
pg. 22
Footnotes, pg. 21
1 Depth includes wallplate and backbox.Wallplate depth is 0.35” (9mm).
2 Depth includes wallplate and backbox.Wallplate depth is 0.48” (12mm).
- Special Function
Controls, pg. 25
- Infrared Controls,
pg. 27
- Radio Frequency
Controls, pg. 29
- Control Interfaces,
pg. 30
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
21
GRAFIK Eye 3000 Series
3000 Series
CONTROLS
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.13” (29mm)1
Wallbox Size: single-gang
Product
Model
Color
Suffix
SCENE SELECTION CONTROL
NTGRX-4S-
Ordering Example
NTGRX-4S-WH
• Recalls preset light levels for four scenes
(1-4, 5-8, 9-12, or 13-16) plus off
• Fine-tuning of light levels with master raise/lower button
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
add color/finish suffix
to model #
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Metal Finishes
Dimensions
4-BUTTON SCENE SELECTION CONTROL
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.13” (29mm)1
• Recalls preset light levels for four scenes
(1-4, 5-8, 9-12, or 13-16)
• No off or fine-tuning of light levels
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
Wallstations—Scene Selectors
Wallbox Size: single-gang
Dimensions
2-BUTTON SCENE SELECTION CONTROL
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.69” (43mm)1
• Recalls preset light levels for two scenes (9/10 or 13/14)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Control can be configured for one of several functions;
for other functions, see pgs. 21, 25
Wallbox Size: single-gang
NTGRX-4B-
W: 1.50” (38mm)
H: 5.16” (131mm)
D: 1.99” (31mm) 2
Wallbox Size:
1.25” (32mm) x 4.40”
(112mm) x 2.75” (70mm)
Dimensions – GRX-4S-DW
W: 1.75” (44mm)
H: 4.50” (114mm)
D: 1.63” (41mm) 2
NTGRX-2B-SL-
Architrave 7-Button Wallstation
GRX-4S-DWArchitrave Large-Button Wallstation
GRX-4SLB-DW• Recalls preset light levels for four scenes
(1-4, 5-8, 9-12, or 13-16) plus off
• Fine-tuning of light levels with master raise/lower button
• Mounts in Lutron-supplied wallbox
• Class 2/PELV control
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Standard finishes are bright brass (BB) and white (WH);
other finishes available with longer lead time
• Controls can be multiganged; wallbox available from Lutron
Footnotes, pg. 22
1 Depth includes wallplate and backbox.Wallplate depth is 0.35”(9mm).
2 Depth includes wallplate and backbox;wallplate depth is 0.13”(3mm).
Wallbox Size:
1.25” (32mm) x 3.80”
(97mm) x 2.75” (70mm)
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
ARCHITRAVE™ DOOR JAMB CONTROLS
Dimensions –
GRX-4SLB-DW
22
Wallstations —Scene Selectors
Ships in 4-6 weeks.
• See pgs.108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
3000 Series
Dimensions
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm)1
Wallbox Size:
UK/German, single-gang
Product
Model
EUROPEAN-STYLE, 4-SCENE
SELECTION CONTROL
EGRX-4S-
Color
Suffix
Ordering Example
• Recalls preset light levels for four scenes
(1-4, 5-8, 9-12, or 13-16) plus off
• Fine-tuning of light levels with master raise/lower button
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in North America
(add NA to P/N–EGRX-4S-NA)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• In addition to wallplate engraving, control buttons can be engraved
EGRX-4S-WH
add color/finish suffix
to model #
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Metal Finishes
Dimensions
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm)1
Wallbox Size:
UK/German, single-gang
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm)1
Wallbox Size:
UK/German, single-gang
Dimensions
W: 2.75” (70mm)
H: 4.50” (114mm)
D: 1.16” (29mm)2
Wallbox Size: single-gang
EGRX-8S-
• Recalls preset light levels for eight scenes
(1-8, 5-12, 9-16, or 13-4) plus off
• Fine-tuning of light levels with master raise/lower button
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in North America
(add NA to P/N–EGRX-8S-NA)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• In addition to wallplate engraving, control buttons can be engraved
EUROPEAN-STYLE, 2-BUTTON SCENE
SELECTION CONTROL
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
EGRX-2B-SL-
• Recalls preset light levels for two scenes (9/10 or 13/14)
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in North America
(add NA to P/N–EGRX-2B-SL-NA)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Control can be configured for one of several functions;
for other functions, see pgs. 21, 25
• In addition to wallplate engraving, control buttons can be engraved
5-BUTTON SCENE SELECTION CONTROL
WITH SLIM BUTTONS
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
• See pgs.108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
Wallstations— Scene Selectors
Dimensions
EUROPEAN-STYLE, 8-SCENE
SELECTION CONTROL
GRAFIK Eye 3000 Series
CONTROLS
Wallstations —Scene Selectors
GRX-KP5-
• Recalls preset light levels for four scenes (1-4 or 6-9)
plus off with fine-tuning or five scenes (1-5 or 6-10)
plus off with full-on (Scene 16)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Amber status LEDs standard
• Control requires additional two weeks for delivery
Function Reference
- Entrance Controls,
pg. 21
- Scene Selectors,
pg. 22
- Special Function
Controls, pg. 25
Footnotes, pg. 23
- Infrared Controls,
pg. 27
1 Depth includes wallplate and backbox.Wallplate depth is 0.48” (12mm).
2 Depth includes wallplate and backbox.Wallplate depth is 0.35” (9mm).
- Radio Frequency
Controls, pg. 29
- Control Interfaces,
pg. 30
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
23
GRAFIK Eye 3000 Series
3000 Series
CONTROLS
Dimensions
W: 2.75” (70mm)
H: 4.50” (114mm)
D: 1.16” (29mm) 1
Wallbox Size: single-gang
Product
Model
10-BUTTON SCENE SELECTION CONTROL
WITH SLIM BUTTONS
GRX-KP10-
W: 4.50” (114mm)
H: 4.50” (114mm)
D: 1.16” (29mm) 1
Wallbox Size:
two-gang
Dimensions
W: 2.75” (70mm)
H: 4.50” (114mm)
D: 1.16” (29mm) 1
Wallbox Size: single-gang
Dimensions
W: 4.50” (114mm)
H: 4.50” (114mm)
D: 1.16” (29 mm) 1
Wallbox Size:
two-gang
Suffix
Ordering Example
GRX-KP10-WH
add color/finish suffix
to model #
• Recalls preset light levels for nine scenes
(1-9 or 6-14) plus off with fine-tuning or
10 scenes (1-10 or 6-15) plus off with full-on (Scene 16)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Amber status LEDs standard
• Control requires additional two weeks for delivery
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
15-BUTTON SCENE SELECTION CONTROL
WITH SLIM BUTTONS
GRX-KP15-
• Recalls preset light levels for Scenes 1-14
plus off with fine-tuning or Scenes 1-15
plus off with full-on (Scene 16)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Amber status LEDs standard
• Control requires additional two weeks for delivery
6-BUTTON SCENE SELECTION CONTROL
WITH LARGE BUTTONS
GRX-LB6-
GRX-LB9-
• Recalls preset light levels for six scenes (1-6 or 9-14)
plus off with fine-tuning of light levels or eight scenes
(1-8 or 9-16) plus off
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Amber status LEDs standard
• Control requires additional two weeks for delivery
1 Depth includes wallplate and backbox. Wallplate depth is 0.35” (9mm).
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
Ships in 4-6 weeks.
• See pgs. 108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
• Recalls preset light levels for three scenes
(1-3 or 9-11) plus off with fine-tuning of
light levels or five scenes (1-5 or 9-13) plus off
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Amber status LEDs standard
• Control requires additional two weeks for delivery
9-BUTTON SCENE SELECTION CONTROL
WITH LARGE BUTTONS
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
Footnote, pg. 24
24
Color
Metal Finishes
Dimensions
Wallstations—Scene Selectors
Wallstations — Scene Selectors
3000 Series
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.69” (43mm)1
Wallbox Size: single-gang
Product
Model
Color
Suffix
2-BUTTON CONTROL
NTGRX-2B-SL-
Ordering Example
NTGRX-2B-SL-WH
• Single partition status determines which GRAFIK Eye
Control Unit(s) operate independently or in combination
to reflect status for one moveable wall (two rooms)
• Panic (Scene 16, lock out GRAFIK Eye Manual Control)
• Sequencing (Selects Scenes 5-16 sequentially)
• Individual Zone Raise/Lower
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Control can be configured for one of several functions;
for other functions, see pgs. 21, 22
add color/finish suffix
to model #
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Metal Finishes
EUROPEAN-STYLE, 2- BUTTON CONTROL
Dimensions
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm) 2
Wallbox Size:
UK/German,
single-gang
4-BUTTON MASTER CONTROL
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.13” (29mm)1
• Each of four buttons toggles selected GRAFIK Eye
Control Unit(s) between Scene 1 and off
• Last button can be all on (Scene 1) -or- all off for
selected GRAFIK Eye Control Unit(s)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
Dimensions
4-BUTTON PARTITIONING CONTROL
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.13” (29mm)1
• Provides four buttons to determine which GRAFIK Eye
Control Unit(s) operate independently or in
combination to reflect partition status for up to
four moveable walls (five rooms)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
Wallbox Size: single-gang
NTGRX- 4M-
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
• See pgs.108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
NTGRX-4PS-
Function Reference
Wallstations — Special Function Controls
• Single partition status determines which GRAFIK Eye
Control Unit(s) operate independently or in combination
to reflect status for one moveable wall (two rooms)
• Panic (Scene 16, lock out GRAFIK Eye Manual Control)
• Sequencing (Selects Scenes 5-16 sequentially)
• Individual Zone Raise/Lower
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in North America
(add NA to P/N–EGRX-2B-SL-NA)
• Class 2/PELV Control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Control can be configured for one of several functions;
for other functions, see pgs. 21, 23
• In addition to wallplate engraving, control buttons can be engraved
Dimensions
Wallbox Size: single-gang
EGRX-2B-SL
GRAFIK Eye 3000 Series
CONTROLS
Wallstations — Special Function Controls
- Entrance Controls,
pg. 21
- Scene Selectors,
pg. 22
- Special Function
Controls, pg. 25
Footnotes, pg. 25
- Infrared Controls,
pg. 27
1 Depth includes wallplate and backbox.Wallplate depth is 0.35”(9mm).
2 Depth includes wallplate and backbox.Wallplate depth is 0.48”(12mm).
- Radio Frequency
Controls, pg. 29
- Control Interfaces,
pg. 30
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
25
GRAFIK Eye 3000 Series
3000 Series
CONTROLS
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 2.00” (51mm) 1
Wallstations —Special Function Controls
Product
Model
Color
KEYSWITCH
NTGRX-KS-
Ordering Example
add color/finish suffix
to model #
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Wallbox Size: single-gang
Metal Finishes
GRX-DACPI-
• Automatically selects preset scenes
in response to ambient daylight
• Enforce option assures photosensor overrides manual
control for energy savings
• Use up to three MW-PS photosensors in parallel
or one (0-10V) photosensor by others
NOTE: MW-PS ordered separately (see below)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
Dimensions
Wallstations — Special Function Controls
NTGRX-KS-WH
• Provides momentary keyswitch control
for all functions of the NTGRX-2B-SL• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
DAYLIGHTING CONTROL
W: 8.94” (224mm)
H: 4.56” (116mm)
D: 2.25” (57mm) 1
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
Wallbox Size: four-gang,
3.50” (89mm) deep
Ships in 4-6 weeks.
Dimensions
diameter: 2.59” (66mm)
depth: 2.16” (55mm)
Ceiling-mounted
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.13” (29mm) 1
Wallbox Size: single-gang
microPS™ CEILING-MOUNTED
PHOTOSENSOR
MW-PS-WH
• Responds to daylight and automatically lowers/adjusts light levels
• Linear response from 0 to 500 footcandles
• Easily calibrated at GRX-DACPI
• Use up to three per GRX-DACPI
• Available in white (WH) only
• Does not count as one out of 16 maximum
Wallstations/Control Interfaces
INFRARED RECEIVER/
SCENE SELECTION CONTROL/
SWITCH INPUT CONTROL
NTGRX-SI4S-IR-
• Recalls preset light levels for four scenes
(1-4 or 5-8 based on external contact closure)
from keypad or Wireless Remote Control
• Fine-tuning from Wireless Remote Control only
• Ideal for two room partitionable spaces
• Allows new scenes to accommodate function of two
single rooms reoriented into one larger room
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
Footnotes, pg. 26
1 Depth includes wallplate and backbox. Wallplate depth is 0.35” (9mm).
26
Suffix
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
• See pgs.108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
3000 Series
Product
Model
4-SCENE WIRELESS REMOTE CONTROL
GRX-IT-WH
Ordering Example
GRX-IT-WH
• Recalls preset light levels for four scenes plus off
(scenes dependent on receiver settings)
• Fine-tuning of light levels with master raise/lower
• 50’(15m) line-of-sight range to receiver
• Does not count as one out of 16 maximum
Wallstations/Control Interfaces
• Infrared frequency is 40kHz
• Available in white (WH) only
Standard, ships in 48 hrs.
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
• See pgs.108–109 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
GRAFIK Eye 3000 Series
CONTROLS
Wallstations—Infrared Controls
Dimensions
W: 1.50” (38mm)
H: 5.69” (145mm)
D: 0.88” (22mm)
8-SCENE WIRELESS REMOTE CONTROL
GRX-8IT-WH
Wallstations — Infrared Controls
• Recalls preset light levels for eight scenes plus off
(scenes dependent on receiver settings)
• Fine-tuning of light levels with master raise/lower
• 50’ (15m) line-of-sight range to receiver
• Does not count as one out of 16 maximum
Wallstations/Control Interfaces
• Infrared frequency is 40kHz
• Available in white (WH) only
Dimensions
W: 1.50” (38mm)
H: 5.69” (145mm)
D: 0.88” (22mm)
CEILING-MOUNTED INFRARED RECEIVER
Ceiling
Visible portion
of receiver
Dimensions
diameter: 3.50” (89mm)
depth: 3.00” (76mm)
GRX-CIR-WH
• Receives signal from Infrared Wireless Remote Control
• Allows recall of preset light levels for four scenes
(1-4, 5-8, 9-12, or 13-16) plus off with four-scene
Wireless Remote Control (GRX-IT)
• Recalls eight scenes (1-8, 5-12, 9-16, or 13-16/1-4)
plus off with eight-scene Wireless Remote Control (GRX-8IT)
• Fine-tuning of light levels with Wireless Remote Control
• 360º reception range, 50’ (15m) line-of-sight
range from Wireless Remote Control to receiver
• Mounts in 2.19” (56mm) x 2.19” (56mm)
collar provided by Lutron
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Available in white (WH) only
Function Reference
- Entrance Controls,
pg. 21
- Scene Selectors,
pg. 22
- Special Function
Controls, pg. 25
- Infrared Controls,
pg. 27
- Radio Frequency
Controls, pg. 29
- Control Interfaces,
pg. 30
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
27
GRAFIK Eye 3000 Series
3000 Series
Wallstations—Infrared Controls
Product
INFRARED RECEIVER/
4-SCENE SELECTION CONTROL
CONTROLS
Model
NTGRX-4S-IR-
NTGRX-4S-IR-WH
add color/finish suffix
to model #
• Recalls preset light levels for four scenes
(1-4, 5-8, 9-12 or 13-16) plus off from keypad
or four-scene Wireless Remote Control (GRX-IT)
or eight scenes (1-8, 5-12, 9-16 or 13-16/1-4)
plus off from eight-scene Wireless Remote Control
(GRX-8IT)
• Fine-tuning of light levels from Wireless Remote Control
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
Matte Finishes
Standard, ships in 48 hrs.
White
WH
Ivory
IV
Beige
BE
Gray
GR
Brown
BR
Black
BL
Metal Finishes
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.13” (29mm)1
Wallbox Size: single-gang
EUROPEAN-STYLE, INFRARED RECEIVER/
4-SCENE SELECTION CONTROL
Wallstations — Infrared Controls
Suffix
Ordering Example
Dimensions
EGRX-4S-IR-
• Recalls preset light levels for four scenes (1-4, 5-8, 9-12 or 13-16)
plus off from keypad or four-scene Wireless Remote Control (GRX-IT)
or eight scenes (1-8, 5-12, 9-16 or 13-16/1-4) plus off from eight-scene
Wireless Remote Control (GRX-8IT)
• Fine-tuning of light levels from keypad or Wireless Remote Control
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in North America
(add NA to P/N—EGRX-4S-IR-NA)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum Wallstations/Control Interfaces
• In addition to wallplate engraving, control buttons can be engraved
Dimensions
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm)2
Wallbox Size: UK/German, single-gang
Consult factory
for pricing.
Ships in 4-6 weeks.
Bright Brass
BB
Bright Chrome
BC
Bright Nickel
BN
Satin Brass
SB
Satin Chrome
SC
Satin Nickel
SN
Antique Brass
QB
Antique Bronze
QZ
Anodized Aluminum
Clear
CLA
Black
BLA
Brass
BRA
Custom Controls,
Color Matching,
and Engraving
Ships in 4-6 weeks.
• See pgs.104–105 for
metal finishes,custom
control options,custom
color matching,and
engraving information.
• See pgs.104–105 for
engraving schedules.
Function Reference
EUROPEAN-STYLE, INFRARED RECEIVER/
8-SCENE SELECTION CONTROL
EGRX-8S-IR-
• Recalls preset light levels for four scenes (1-4, 5-8, 9-12, or 13-16)
plus off from four-scene Wireless Remote Control (GRX-IT)
or eight scenes (1-8, 5-12, 9-16 or 13-16/1-4) plus off from keypad or
eight-scene Wireless Remote Control (GRX-8IT)
• Fine-tuning of light levels from keypad or Wireless Remote Control
• Mounts in UK/German wallbox
• Wallbox supplied by Lutron in North America
(add NA to P/N—EGRX-8S-IR-NA)
• Class 2/PELV control wiring
• Counts as one out of 16 maximum Wallstations/Control Interfaces
• In addition to wallplate engraving, control buttons can be engraved
Dimensions
W: 3.38” (86mm)
H: 3.38” (86mm)
D: 0.88” (22mm)2
Wallbox Size: UK/German, single-gang
Footnotes, pg. 28
1 Depth includes wallplate and backbox.Wallplate depth is 0.35” (9mm).
2 Depth includes wallplate and backbox.Wallplate depth is 0.48” (12mm).
28
Color
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
- Entrance Controls,
pg. 21
- Scene Selectors,
pg. 22
- Special Function
Controls, pg. 25
- Infrared Controls,
pg. 27
- Radio Frequency
Controls, pg. 29
- Control Interfaces,
pg. 30
3000 Series
Product
Model
RadioRA® /GRAFIK Eye INTERFACE
RA-GRXI-WH
Ordering Example
RA-GRXI-WH
• Allows GRAFIK Eye preset lighting controls
to be controlled by Radio Frequency where
Wireless Remote Control is needed
• GRAFIK Eye preset lighting scenes can be selected
from any RadioRA Master Control in the system
• Use in larger RadioRA Systems since each interface
counts as one device toward the RadioRA System
• A RadioRA System can have a maximum of
32 dimmers/switches/GRAFIK Eye Interfaces
• Use one interface per room controlled by a
GRAFIK Eye preset lighting control; do not link
to multiple GRAFIK Eye Control Units in different rooms
Standard, ships in 48 hrs.
GRAFIK Eye 3000 Series
I N T E R FA C E S /
CONTROLS
Wallstations — RF Interfaces and Controls
Dimensions
W: 2.75” (70mm)
H: 4.56” (116mm)
D: 1.67” (42mm)1
Wallbox Size: single-gang
RadioRA RF SIGNAL REPEATER
RA-REP-WH
• Required for system communication
• For more information, contact Lutron
RAMC-5T-
• Master control to turn lights on to preset levels
• For more information, contact Lutron
RAMC-10TRAMC-15TRAMC-10C-WH
RAMC-5WRAMC-10WRAMC-15W-
Wallstations — Radio Frequency Interfaces and Controls
RadioRA MASTER CONTROLS
Footnote, pg. 29
1 Depth includes wallplate and backbox.Wallplate depth is 0.30” (8mm).
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
29
GRAFIK Eye 3000 Series
3000 Series
Control Interfaces
Architectural Grade
• Integrates other systems to GRAFIK Eye 3000 Series Control Units
- dry contact closures (input and output)
- RS232
- DMX512
• Up to 16 Wallstations and Control Interfaces can be added for a total of 24
control points in one system
• For design guidelines using Wallstations and Control Interfaces, see pgs. 8–9
Available Functions
12
34
Contact
Closure
5.0”w (127mm) x 7.75”h (197mm)
Timeclock
Fire Alarm
System
Security
System
Occupancy
Sensor
Sequencing
GRAFIK Eye 3000
SYSTEM MAP
Control Interfaces
• Use the map at right to identify system
component being reviewed in each section
• Mini map is duplicated at the bottom of
each two-page spread for easy reference
Sources
Incandescent
Magnetic Low-Voltage
Electronic Low-Voltage*
Fluorescent*
Neon/Cold Cathode
Lutron Tu-Wire™
High-Intensity Discharge*
(non-dim only)
* Interface required to dim.
Consult product pages for specifics.
SPECIAL DESIGN
C O N S I D E R AT I O N S
Standards listed below apply to one or more
products in the Grafik Eye product line.
Consult factory for specific information.
30
LUTRON
Quality Systems
registered
to ISO 9001
www.lutron.com
• Wallstation and Control Interface Maximums:
- Per System: 16 (Class 2/PELV)
- Three (Class 2/PELV) from each GRAFIK Eye Control Unit
without external power supply
- For Lutron Power Supply, order GRX-12VDC, see pg. 90
• Wiring Specification & Maximums:
- Wire: two twisted pair #18 AWG (1.0mm 2)
For Lutron non-plenum cable, order GRX-CBL 346S-500, pg. 90
- Distance: 2,000’ (610m)
For other cable distances, see GRAFIK Eye Application
Notes available at www.lutron.com
- Installation: Daisy chain (no home-run wiring)
• Power: 12VDC (From GRAFIK Eye 3000 Series Control Unit or GRX-12VDC)
• Configuration:
- Integral DIP switches determine function, and can be configured in the field
• Mounting: 4.00” square utility box unless otherwise noted
Lutron World Headquarters: 1.610.282.3800
A B
Lockout
Partitioning
3000 Series
Dimensions
W: 5.00” (127mm)
H: 7.75” (197mm)
D: 2.50” (64mm)
Mounts on
4.00”-square utility box
Product
Model
RS232 INTERFACE
GRX-RS232
• Integrates GRAFIK Eye Control Units with
user-supplied PC or A/V equipment (touchscreen) using RS232
serial communication
• Enables control of scene selection, scene lock,
sequencing, zone lock, zone raise/lower
• Can provide status monitoring through
button feedback and scene-status updates
• Class 2/PELV control wiring
• Must be located within 50’(15m) of RS232 source
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
12
34
Dimensions
W: 5.00” (127mm)
H: 7.75” (197mm)
D: 2.50” (64mm)
Mounts on
4.00”-square utility box
GRAFIK Eye 3000 Series
CONTROL
I N T E R FA C E S
Control Interfaces
A B
ASTRONOMIC TIMECLOCK
PROGRAMMER INTERFACE
GRX-PRG
12
34
Control Interfaces
• Includes all features of GRX-RS232
• Built-in astronomic timeclock features
four schedules with 60 events per schedule
• Programmed with IBM-compatible PC (not included)
using Lutron Liaison™ software (included)
• Provides access to advanced user-programmable features
when used with GRX-3500/4500 Control Units such as
programming scenes and system communications
• Class 2/PELV control wiring
• Must be located within 50’(15m) of RS232 source
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• Only one GRX-PRG per system
A B
Function Reference
- Entrance Controls,
pg. 21
Dimensions
DMX512 INTERFACE
W: 5.00” (127mm)
H: 7.75” (197mm)
D: 2.50” (64mm)
• Converts GRAFIK Eye Control Unit intensities
Mounts on
4.00”-square utility box
to DMX512 Output
• Use to control:
- Fiber optic lighting
- LED-based lamps
- Strobe lights
- Fogger machines
- Moving fixtures
- Animated characters
• Class 2/PELV control wiring
• DMX–send (output DMX intensities) only
LUT-DMX
- Scene Selectors,
pg. 22
- Special Function
Controls, pg. 25
- Infrared Controls,
pg. 27
- Radio Frequency
Controls, pg. 29
- Control Interfaces,
pg. 30
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
31
CONTROL
I N T E R FA C E S
Control Interfaces
Product
Model
CONTACT CLOSURE INTERFACE
GRX-AV
• Provides two-way interface between GRAFIK Eye
Control Units and contact closure devices
• Functions listed can be activated by external
manual or automated devices
• Provides five inputs and five outputs
• Class 2/PELV control wiring
• Counts as one out of 16 maximum
Wallstations/Control Interfaces
• For more information, see Application Notes, pg. 93.
Dimensions
MUX
+V
MUX
COM
1 2 3 4
MUX Link
+
V
–
4
3
5
C 1 2 3 4 5 1 2 3 4 5 C
Program
Switch
Control Interfaces
1
Power
Supply
Output 5
To GRAFIK Eye
Control Unit
2
32
Output 4
Output 3
Output 2
Output 1
Input 5
Input 4
Input 1
Mounts on a
4.00”-square utility box
Input 3
Customer Supplied Equipment
W: 5.00” (127mm)
H: 7.75” (197mm)
D: 2.50” (64mm)
Input 2
GRAFIK Eye 3000 Series
3000 Series
Inputs
Outputs
GRX-AV
To additional Wallstations/
Control Interfaces
Inputs
Outputs
General
• Inputs (five) must be dry contact type only
• Inputs can be momentary or maintained
• Inputs must have:
- On-state saturation voltage less than 2.0VDC
- Off-state leakage current less than 10µA
• Input must have a pulse time of
40 msec or longer
General
• Outputs (five) can be used to control
other manufacturers’ equipment
• Customer-provided output indicators must
not exceed 200mA at 30VDC (Class 2/PELV)
• Provides a maintained or a one-second
momentary output closure
• Output requires external relay and power
supply (30VDC maximum) by others for
contact closure
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
3000 Series
Control Interfaces
Outputs
G R X - AV F U N C T I O N S
Scene
Select
Input
• Inputs initiate four scenes
(1-4, 5-8, 9-12, or 13-16) plus off
• One contact required for each scene
selection including off
• Scene select on GRAFIK Eye
Control Unit can trigger outputs
(one per each scene and off) to
control other equipment
• Output can be momentary or
maintained
• Input initiates “panic” mode:
Selects Scene 16 and locks GRAFIK Eye
Control Unit to prevent manual changes
• Returns to previous scene when
closure is removed
• Output can be used to provide status
feedback to other equipment
• Output is maintained only
Occupant
Response
Input
• Inputs turn selected GRAFIK Eye
Control Unit(s) on to Scene 1 or off
based on room occupancy
• Up to five independent rooms can be
handled with one GRX-AV
• Outputs can be used to provide
status feedback to other equipment
• Output is maintained only
Sequencing
Input
• Input initiates dynamic changes through
Scenes (1-4 or 5-16) sequentially
• Output can be used to provide status
feedback to other equipment
• Output is maintained only
Zone
Lockout
Input
• Input initiates zone lock:
Allows intensity changes on selected
GRAFIK Eye Control Unit(s) without
affecting preset scenes
• Output can be used to provide status
feedback to other equipment
• Output is maintained only
Scene
Lockout
Input
• Input initiates scene lock:
Disables scene buttons on selected
GRAFIK Eye Control Unit(s) preventing
any manual scene changes
• Output can be used to provide status
feedback to other equipment
• Output is maintained only
Partition
Input
• Inputs determine which GRAFIK Eye
Control Unit(s) operate independently
or in combination to reflect partition
status for up to five moveable walls
(six rooms)
• Outputs can be used to provide status
feedback to other equipment
• Output is maintained only
Timeclock
Fire
Alarm
Input
GRAFIK Eye 3000 Series
Inputs
Security
System
Input
A B
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
Control Interfaces
12
34
33
GRAFIK Eye 3000 Series
3000 Series
Wiring Diagrams
Wiring Diagram #1
GRAFIK Eye 3000 Series
Control Unit Power and Load Wiring
Earth/Ground from Distribution Panel
Distribution Panel
Hot/Live
2 #12 AWG
Load 2
2 #12 AWG
ZONE 2
Load 4
2 #12 AWG
ZONE 4
Load 6
2 #12 AWG
ZONE 6
CU WIRE ONLY
ZONE 1
2 #12 AWG
Load 1
ZONE 3
2 #12 AWG
Load 3
ZONE 5
2 #12 AWG
Load 5
(2.5mm2)
(2.5mm2)
(2.5mm2)
Hot/Live
HOT/LIVE
CLASS 2
1 2 3 4
SSA
Neutral
USA
Class 2
IEC
PELV
NEUTRAL
Rear View of GRAFIK Eye Control Unit (GRX-3106 shown)
Neutral
Wiring Diagrams
Notes:
1. Each line voltage terminal can accept up to two #12 AWG
(2.5mm2) wires.
2. Each Class 2/PELV terminal can accept up to two #18 AWG
(1.0mm2) wires.
3. For non-dim relay wiring, see Application Notes pg. 93.
4. For load side emergency transfer wiring, see Application
Notes pg. 92.
5. Input wiring for Lutron Tu-Wire ballasts is the same as
wiring shown above for loads 1-6.
Wiring Diagram #2
GRAFIK Eye 3000 Series
Dual Feed Power Option Wiring
Breaker Panel
ZONE 2
Sub-feed Panel
ZONE 4
ZONE 1
CU WIRE ONLY
15A 15A
OFF OFF
ON ON
ON
OFF
20A
ZONE 6
Hot/Live
SW HOT/LIVE 2
HOT/LIVE 2
ZONE 5
CLASS 2
1 2 3 4
SSA
Hot/Live
Neutral (See Note #6)
1
2
3
4
5
1
2
3
4
5
Notes:
1.For 2-circuit feed, both circuit breakers must be on the same phase.
2.Use a 2-pole circuit breaker that disconnects simultaneously all ungrounded
conductors at the panelboard where the branch circuit originates.
3.The 2-pole breaker may need to be located in a separate sub-feed panel.
4.Dual Feed Power Option is not available on standard GRAFIK Eye Control Units.
Consult Lutron for details on how to order Control Units with Dual Feed Option.
5.For use where electrical code has maximum 15A branch breaker requirements for
lighting applications.
6.Consult local code regarding wire size for neutral run.
Two neutral wires may need to be run.
34
www.lutron.com
ZONE 3
Lutron World Headquarters: 1.610.282.3800
SW HOT/LIVE 1
HOT/LIVE 1
NEUTRAL
3000 Series
Wiring Diagrams
GRAFIK Eye 3000 Series
Wiring Diagram #3
GRAFIK Eye 3000 Series
Control Unit to Wallstation Wiring
Earth/Ground from Distribution Panel
Rear View of GRAFIK Eye
Control Unit (GRX-3106 shown)
ZONE 2
Distribution Panel
ZONE 4
ZONE 1
ZONE 3
CU WIRE ONLY
ZONE 6
Hot/Live
Hot/Live
2 #12 AWG
HOT/LIVE
(2.5mm2)
Neutral
ZONE 5
CLASS 2
1 2 3 4
SSA
Line
Voltage
wiring
USA
Class 2
IEC
PELV
NEUTRAL
Neutral
Black
Data Link
3: MUX
4: MUX
Blue
Class 2/PELV
Control Wiring
1: Common
2: 12VDC
Wallstation
Wallstation
123456
Lutron Cable,
GRX-CBL-346S
123456
4
3
2
1
4
3
2
1
Wallstation
123456
4
3
2
1
NTGRX-1S
(10 Maximum)
Wiring Diagrams
Notes:
1. For other possible NTGRX-1S wiring configurations, see GRAFIK Eye
Application Notes available at www.lutron.com.
2. The NTGRX-1S is for use with 3-, 4- and 6-zone Control Units only.
3. Each Control Unit can power up to three Class 2/PELV Wallstations/ Control
Interfaces. If more than three need to be connected to one Control Unit,
install an external 12VDC power supply as shown in Diagram #6.
Wiring Diagram #4
GRAFIK Eye 3000 Series
Control Unit to Unit Wiring
Rear View of GRAFIK Eye Control Unit (GRX-3106 shown)
Rear View of GRAFIK Eye Control Unit (GRX-3106 shown)
ZONE 2
ZONE 1
ZONE 2
ZONE 4
ZONE 3
ZONE 4
ZONE 5
ZONE 6
CU WIRE ONLY
ZONE 6
HOT/LIVE
SSA
CLASS 2
1 2 3 4
USA
Class 2
IEC
PELV
HOT/LIVE
NEUTRAL
SSA
ZONE 1
CU WIRE ONLY
ZONE 3
ZONE 5
CLASS 2
1 2 3 4
USA
Class 2
IEC
PELV
NEUTRAL
Notes:
1. Each Control Unit has its own power supply.
2. Do not connect terminal No. 2 when wiring between
GRAFIK Eye 3000 Series Control Units. Class 2/PELV cable
is available from Lutron, order GRX-CBL-346S.
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
35
GRAFIK Eye 3000 Series
3000 Series
Wiring Diagrams
Wiring Diagram #5
GRAFIK Eye 3000 Series
3000 Series System Wiring
Rear View of GRAFIK Eye Control Unit
(GRX-3106 shown)
Rear View of GRAFIK Eye Control Unit
(GRX-3106 shown)
A1
1 2 3 4
4
3
2
1
1 2 3 4
A2 and A3
have their own
power supplies –
No terminal No. 2
connection
1
A3 powers Wallstations
2, 3, and 4 – No terminal
No. 2 connection
between Wallstations
4 and 5
2
4
3
2
1
4
3
2
1
5
A3
6
7
A4 powers Wallstations
5, 6, and 7 – No terminal
No. 2 connection between
Wallstations 4 and 5
3
A1 powers 1 only –
terminal No. 2 connection
terminates at Wallstation 1
A2
4
3
2
1
4
3
2
1
4
3
2
1
4
A4
4 3 2 1
4
3
2
1
4 3 2 1
4
3
2
1
Rear View of GRAFIK Eye Control Unit
(GRX-3106 shown)
Wiring Diagrams
Maximum length of
T-tap is 8’ (2.5m)
4
3
2
1
4
3
2
1
4
3
2
1
Total Class 2/PELV
wiring length is
2,000’ (600m)
Rear View of GRAFIK Eye Control Unit
(GRX-3106 shown)
Notes:
1. Up to eight GRAFIK Eye 3000 Series Control Units and 16
Wallstations/Control Interfaces can be daisy chained together in one system.
2. Class 2/PELV cable is available from Lutron, order GRX-CBL-346S.
Wiring Diagram #6
GRAFIK Eye 3000 Series
GRX-12VDC Power-Supply Wiring
Rear View of GRAFIK Eye Control Unit (GRX-3106 shown)
ZONE 2
ZONE 4
ZONE 1
CU WIRE ONLY
ZONE 6
HOT/LIVE
SSA
ZONE 3
ZONE 5
CLASS 2
1 2 3 4
USA
Class 2
IEC
PELV
Lutron cable,
GRX-CBL-346S
Wallstation
Wallstation
Wallstation
Wallstation
NEUTRAL
1 twisted pair
#18 AWG (1.0mm2)
2 twisted pair
#18 AWG (1.0mm2)
123456
4
3
2
1
1 #18 AWG
(1.0mm2)
123456
4
3
2
1
123456
4
3
2
1
123456
4
3
2
1
Common
(+) 12VDC
Wallstations/Control Interfaces
(16 Maximum)
To Power Source
GRX-12VDC
Note:
Do not connect terminal No. 2 between GRAFIK Eye 3000 Series Control Unit and GRX-12VDC Power Supply.
36
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
3000 Series
ZONE 3
ZONE 2
ZONE 1
2
1
+
V
–
4
3
Power
Supply
Output 5
Output 4
Output 3
Output 2
Input 5
Input 4
Input 3
Input 2
4
3
2
1
USA: Class 2
IEC: PELV
SSA
Input 1
CU WIRE ONLY
CLASS 2
HOT/LIVE
Output 1
Customer-Supplied Equipment
Lutron Cable,
GRX-CBL-346S
NEUTRAL
GRAFIK Eye 3000 Series
Wiring Diagram #7
GRAFIK Eye 3000 Series
GRX-AV Control Interface Wiring
Wiring Diagrams
5
Rear View of GRAFIK Eye Control Unit
(GRX-3103 shown)
Program
Switch
C 1 2 3 4 5 1 2 3 4 5 C
MUX
+V
MUX
COM
1 2 3 4
MUX Link
Inputs
Outputs
GRX-AV
To additional Wallstations/
Control Interfaces
(16 Maximum; three from
one Control Unit without
external 12VDC power supply)
Note:
For more information, see Application Notes pg. 93.
NEUTRAL
HOT/LIVE
CU WIRE ONLY
50' (15m) Maximum
COM
4
3
2
1
TxD
PC or A/V
Equipment
RxD
USA: Class 2
IEC: PELV
SSA
CLASS 2
Lutron Cable,
GRX-CBL-346S
ZONE 3
ZONE 2
ZONE 1
Rear View of GRAFIK Eye Control Unit
(GRX-3103 shown)
1 2 3 4
1 2 3 4 5
MUX Link
RS232 Link
Wiring Diagrams
Wiring Diagram #8
GRAFIK Eye 3000 Series
GRX-RS232 Control Interface Wiring
GRX-RS232/GRX-PRG
To additional Wallstations/
Control Interfaces
(16 Maximum; three from
one Control Unit without
external 12VDC power supply)
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
37
Wiring Diagrams
Wiring Diagram #9
GRAFIK Eye 3000 Series
Control Unit to HP 2•4•6™ Wiring
HP 2•4•6
Control
Circuit
Terminals
N N H H DH 1 2 3
Control Circuit Feed:
See Note 1 Below
Neutral
To additional
HP 2•4•6
Modules
(Five Maximum)
Hot/Live
Dimmed Hot
120VAC
Feed from Neutral
Distribution
Hot
Panel
NEUTRAL
HOT/LIVE
CU WIRE ONLY
SSA
CLASS 2
GRAFIK Eye 3000 Series
3000 Series
4
3
2
1
USA: Class 2
IEC: PELV
ZONE 3
To additional
loads
ZONE 2
ZONE 1
Wiring Diagrams
Rear View of GRAFIK Eye Control Unit
(GRX-3103 Shown)
Notes:
1. Control Circuit feed is shown coming from the GRAFIK Eye Control Unit’s feed. The load for each HP
2•4•6 module connected to the circuit is 20W/VA. If the circuit does not have sufficient capacity to
support the load of the module(s), the HP 2•4•6 Control Circuit feed can be supplied from any 120VAC
circuit with sufficient capacity as long as it is on the same phase as the GRAFIK Eye Control Unit. Do
not use with generator-supplied power.
2. Load type should be set as incandescent on the GRAFIK Eye Control Unit.
3. Dimmed Hot is shown as Zone 1 in the diagram, but can be provided from any zone on the Control Unit.
4. For GRAFIK Eye 3000 Series Control Units, refer to GRAFIK Eye 3000 Instruction Sheet (P/N 032-083)
for the remainder of Control Unit wiring.
5. Refer to HP 2•4•6 Instruction Sheet (P/N 030-452) for the remainder of HP 2•4•6 wiring.
Wiring Diagram #10
GRAFIK Eye 3000 Series
Control Unit to PB/ELVI
Power Booster/Interface Wiring
Rear View of PB/ELVI
Neutral
NEUTRAL
HOT/LIVE
CU WIRE ONLY
SSA
ZONE 2
ZONE 1
Load
4
3
2
1
USA: Class 2
IEC: PELV
ZONE 3
CLASS 2
Neutral N
Zone In
Do Not Use
Hot/Live
Earth/Ground
Zone Out
Hot/Live
Load Neutral
Feed 1 from
Distribution
Panel
Rear View of
GRAFIK Eye Control Unit
(GRX-3103 Shown)
Neutral
Hot/Live
Feed 2 from
Distribution
Panel
Notes:
1. Each terminal can accept up to two #12AWG (2.5mm2) wires.
2. PB/ELVI Hot/Live can be on the same phase or different phase than the GRAFIK Eye 3000 Series Control Unit Hot/Live.
38
www.lutron.com
Lutron World Headquarters: 1.610.282.3800
3000 Series
Wiring Diagrams
GRAFIK Eye 3000 Series
Wiring Diagram #11
GRAFIK Eye 3000 Series
Control Unit to FDBI
Power Interface Wiring
Rear View of FDBI
NEUTRAL
CLASS 2
Neutral N
Zone In
Neutral
SW Hot/Live
Hot/Live
Earth/Ground
Zone Out
Hot/Live
CU WIRE ONLY
HOT/LIVE
SSA
4
3
2
1
ZONE 2
Lutron Hi-Lume
or Eco-10 Ballast
ZONE 1
Orange
Rear View of
GRAFIK Eye Control Unit
(GRX-3103 Shown)
USA: Class 2
IEC: PELV
ZONE 3
Feed 1 from
Distribution
Panel
Hot/Live
Black
White
Load Neutral
Neutral
Feed 2 from
Distribution
Panel
Earth/Ground
Notes:
1. Each terminal can accept up to two #12 AWG (2.5mm2) wires.
2. FDBI Hot/Live can be on the same phase or different phase than the GRAFIK Eye 3000 Series Control Unit Hot/Live.
3. Lutron Tu-Wire™ ballasts do not require the use of FDBI Power Interface.
Wiring Diagram #12
GRAFIK Eye 3000 Series
Control Unit to GRX-TVI
Power Interface Wiring
GRX-TVI
Wiring Diagrams
0-10VDC Control Signal Wires DO NOT CONNECT TO LINE VOLTAGE.
Lutron is not liable for damage due
to miswiring.
0-10V
L1/H1
N1
N1
SL1/SH1
L2/H2 220-240V
L2/H2 100-120V
N2
DL2/DH2
LED
–
+
N2 DL2/DH2
220100-127V
240V
L2/H2
Control Inputs
Rear View of GRAFIK Eye Control Unit
(GRX-3106 shown)
ZONE 2
ZONE 4
ZONE 1
CU WIRE ONLY
ZONE 6
HOT/LIVE
SSA
Dimmed
Hot/Live
L1/H1
100277V
N1
N1
SL1/SH1
+
–
0-10V
Max 0.3A
Load Switched
USA
CLASS 2
IEC
PELV
ZONE 3
NEUTRAL
0-10VDC Ballast
Neutral
Switched Hot/Live
Neutral
Earth/Ground
–
ZONE 5
CLASS 2
1 2 3 4
Switched Hot
Neutral
Earth/Ground
Connections
+
Switched Hot
0-10VDC Ballast
Neutral
Earth/Ground
Hot/Live
Distribution
Panel A
Hot/Live
Neutral
Earth/Ground
Distribution
Panel B
Hot/Live
Neutral
Earth/Ground
To additional ballasts
Note:
Distribution panels can be different phases or voltages (120VAC shown).
Technical Hotline: 1.800.523.9466…24 hours/7 days (US/CAN) To Order: 1.888.LUTRON1…8a.m.–8p.m./M-F ET (US/CAN)
39
Download