CHAPTER 19 Electrical Plans I N T R O D U C T I O N The electrical plans display all of the circuits and systems to be used by the electrical contractor during installation. Electrical installation for new construction occurs in these three phases: ● Temporary. The installation of a temporary underground or overhead electrical service near the construction site and close to the final meter location provides electricity during construction. ● Rough-in electrical. Also known as simply “rough-in” or prewiring, this is when the electrical boxes and wiring are installed. Rough-in happens after the structure is framed and covered with roofing. The electrical meter and permanent service can also be installed at this time. ● Finish electrical. This is when the light fixtures, outlets and covers, and appliances are installed prior to occupancy. Finish electrical is one of the last construction phases. Electrical plans can be placed on the floor plan with all the other symbols, information, and dimensions as discussed in Chapter 16 through Chapter 18. This is a common practice on simple floor plans where the addition of the electrical symbols does not overcomplicate the drawing. Another option is to draw electrical plans on a separate sheet that displays the floor plan walls and key symbols, such as doors, windows, stairs, fireplaces, cabinets, and room labels. This chapter takes the second approach but provides a discussion on how both methods are used. ELECTRICAL TERMS AND DEFINITIONS A number of terms are unique to electrical applications. It is important to be familiar with key electrical terminology to help you understand this chapter and communicate effectively. The following are terms that are commonly associated with electricity and electrical construction: Ampere: A measurement of electrical current flow. Referred to by its abbreviation amp or amps. Box: A box equipped with clamps, used to terminate a conduit. Also known as an electrical box or outlet box. Connections are made in the box, and a variety of covers are available for finish electrical. A premanufactured box or casing is installed during electrical rough-in to house the switches, outlets, and fixture mounting (see Figure 19-1 and Electrical work below). Breaker: An electric safety switch that automatically opens a circuit when excessive amperage occurs. Also referred to as a circuit breaker. Circuit: The various conductors, connections, and devices found in the path of electrical flow from the source through the components and back to the source. Conductor: A material that permits the free motion of electricity. Copper is a common conductor in architectural wiring. Conduit: A metal or fiber pipe or tube used to enclose one or more electrical conductors. CADD APPLICATIONS CADD provides an excellent tool for creating electrical plans after the floor plans are drawn. Unneeded floor plan layers are turned off or frozen with electrical layers turned on to create the electrical plan. It is easy to create a separate drawing from the key elements of the base drawing in this manner. ■ 431 432 Architectural Drafting and Design STUD electrical system. The installation of the wiring is referred to as the rough-in. Rough-in takes place after the framing is completed and the structure is dried-in. Dried-in refers to installing the roof or otherwise making the building dry. The light fixtures, outlets, and all other final electrical work are done when the construction is nearly complete. This is referred to as the finish electrical. Temporary, rough-in, and finish electrical make up the electrical work. WIRE OUTLET BOX BOTTOM PLATE Ground: An electrical connection to the earth by means of a rod. A Junction box: A box that protects electrical wiring splices in conductors or joints in runs. The box has a removable cover for easy access (see Figure 19-1). JOIST OR RAFTER (STUD IF WALL MOUNTED) Lighting outlet: An electrical outlet that is intended for the direct connection of a lighting fixture (see Figure 19-1). WIRE Meter: An instrument used to measure electrical quantities. The electrical meter for a building is where the power enters and is monitored for the electrical utility. Meter base: The mounting base on which the electrical meter is attached. It contains all of the connections and clamps. OUTLET BOX B Switch leg: The electrical conductor from a switch to the electrical device being controlled. COVER JOIST OR RAFTER (STUD IF WALL MOUNTED) JUNCTION BOX WIRE C Outlet: An electrical connector used to plug in devices. A duplex outlet, with two outlets, is the typical wall plug. CONNECTION FASTENER FIGURE 191 Installation of outlets and junction box. (A) Outlet box. (B) Lighting outlet. (C ) Junction box. Temporary electric service: This service is provided during construction and is used for construction electricity purposes. This service is installed on a temporary pole, which is placed near the permanent power pole or transformer. The temporary service has a meter base and meter, and usually two 20-ampere, 120-VAC, grounded, duplex outlets and one 50-ampere, four-wire, single phase, 240-VAC (208-VAC at some locations) outlet mounted in a weatherproof enclosure. Volt: The unit of measure for electrical force. Watt: A unit measure of power. Distribution panel: Where the conductor from the meter base is connected to individual circuit breakers, which are connected to separate circuits for distribution to various locations throughout the structure. Also known as a panel. Electrical work: The installation of the wiring and fixtures for a complete residential or commercial ELECTRICAL CIRCUIT DESIGN Due to the number of electrical appliances that make modern living enjoyable, the design of the electrical circuits in a home is important. Discuss with the client any anticipated needs for electric energy in Chapter 19: Electrical Plans the home. Such a discussion includes the intended use of each of the rooms and the potential placement of furniture in them. Try to design the electrical circuits so there are enough outlets and switches at convenient locations. Electrical code requirements state the size of some circuits and the placement of certain outlets and switches within the home. Refer to Chapter 9. In addition to convenience and code requirements, you should consider cost. A client may want outlets 4' (1220 mm) apart in each room, but the construction budget may not allow for such a luxury. Try to establish budget guidelines and then work closely with the client to achieve desired results beyond minimum code requirements. Although switches, convenience outlets, and electrical wire and boxes may not seem to cost very much individually, their installation in great quantity can be costly. In addition, attractive and useful light fixtures required in most rooms can also be very expensive. BASIC ELECTRICAL DESIGN RECOMMENDATIONS Electrical systems should be designed for convenience of use and to meet minimum code requirements. Common codes and convenience applications to consider when designing electrical circuits are described in the following: ● ● ● ● ● ● ● ● Duplex convenience outlets should be a maximum of 12' (3657 mm) apart. Closer spacing is desirable, although economy is a factor. Duplex convenience outlets, also called duplex outlets or outlets, are a standard electrical outlet with two plug receptacles. Duplex outlets should be no more than 6' (1820 mm) from an opening. Each wall over 2' (610 mm) in length must have an outlet. Consider furniture layout, if possible, so duplex outlets do not become inaccessible behind large pieces of furniture. Place a duplex outlet next to or behind a desk or table where light is needed or near a possible reading area. Place a duplex outlet near a fireplace, for an adjacent table light, for a vacuum, or for fireplace maintenance. Place a duplex outlet in a hallway, for a vacuum. Duplex outlets should be placed close together in kitchens and installed where fixed and portable 433 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● appliances are located for use. Outlets are required every 4' (1200 mm) of counter space, no more than 2' (600 mm) from a corner, end of counter, or appliance. Some designs include an outlet in a pantry for use with portable appliances. Kitchen, bathroom, laundry, and outdoor circuits are required to be protected by a ground fault circuit interrupter (GFCI or GFI), which trips a circuit breaker when there is any unbalance in the circuit current. The standard breaker condition is 0.005-amp fault in 1/40 second. This protection is required for any electric fixture within 6' of water. Fixtures and appliances produce a potential hazard for electrocution. Outlets in garages and outbuildings must be GFCI. All exterior outlets must be waterproof and GFCI. Each bathroom sink or makeup table should have a duplex outlet. Each enclosed bath or laundry/utility room should have an exhaust fan. Rooms with operable windows do not require fans, although fans are desirable. A lighting outlet with light fixture is necessary outside all entries and exterior doors. A waterproof duplex outlet should be placed at a convenient exterior location, such as a patio. This exterior outlet must have a GFCI if within direct grade level access. Ceiling lights are common in children’s bedrooms for easy illumination. Master bedrooms may have a switched duplex outlet for a bedside lamp. The kitchen may have a light over the sink, although this may be an extra light in a very well-lighted kitchen. Bathroom lights are commonly placed above the mirror at the vanity and located in any area that requires additional light. In a large bath, a recessed waterproof light should be placed in a shower or above a tub. Place switches in a manner that provides the easiest control of the lights. Locate lights in large closets or any alcove or pantry that requires light. Light stairways well, and provide a conveniently located switch at each level. Place lights and outlets in garages or shops in relationship to their use. For example, a welder or other shop equipment requires 220-volt (V) outlets. Place exterior lights properly to illuminate walks, drives, patios, decks, and other high-use areas. 434 GOING GREEN Energy Conservation Energy efficiency is a very important consideration in today’s home design and construction market. Many steps can easily contribute to energy savings for the home owner with little additional cost. Some of these energy-efficient construction applications can be explained by specific or general notes or are included in construction specifications. Other methods must be described with detail drawings. Energy-efficient considerations related to electrical design include the following: • Keep electrical outlets and recessed appliances or panels to a minimum at exterior walls. Any units recessed into an exterior wall can eliminate or severely compress the insulation and reduce its insulating value. • Fans or other systems exhausting air from the building should be provided with back draft or automatic dampers to limit air leakage. • Timed switches or humidistats should be installed on exhaust fans to control unnecessary operation. • Electrical wiring is often located in exterior walls at a level convenient for electricians to run wires. This practice causes insulation to become compacted, HOME AUTOMATION Many modern homes are being built with automation systems. This technology is rapidly changing and requires that you continuously research the available products and installations. Designing and installing a home-automation system allows the builder to sell the same-square-footage home for more and increases marketability. Automation is a method or process of controlling and operating mechanical devices other than human power. Such operations include the computerized control of the heating, ventilating, air-conditioning, landscape sprinkling systems, lighting, and security systems. The design and drafting of the home-automation systems can be done by the product supplier or by the architect or designer. Electrical symbols and specific notes are placed on the floor plan or on separate drawings and in specifications used for construction purposes. The following briefly describes some of the many homeautomation system options and features available. • • • • • resulting in a loss of insulating value. Wires could be run along the bottom of the studs at the bottom plate. Preparing the studs is easily accomplished during framing by cutting a V groove in the stud bottoms while the studs are piled at the site after delivery. Select energy-efficient appliances such as a selfheating dishwasher or a high-insulation water heater. Evaluate the vendor’s energy statement before purchase. Use energy-saving fluorescent lighting fixtures where practical, such as in the kitchen, laundry/utility room, garage, or shop. Fully insulate above and around recessed lighting fixtures. Verify code and manufacturer specifications for this practice. Carefully caulk and seal around all light and convenience outlets. Also, caulk and seal where electrical wires penetrate the top and bottom plates. Use recessed lights that are IC (insulation cover) rated. This allows you to insulate around and over the recessed light to help avoid heat loss. For example, pressing one button automatically dims the lights, opens the curtain, and begins the movie. The home theater can be part of a living or family room, or designed into a special theater room with theater-style seating. Home entertainment centers can also provide sound throughout the home using a variety of sources, such as MP3 players, DVDs, and satellite radio. Computerized Programming Computerized programming of house functions from a personal computer allows you to use a computer to set and monitor a variety of electrical circuits throughout the home, including security, sound, yard watering, cooking, and lighting. Home-automation systems often place the computer monitors in locations such as the kitchen or office where there is frequent activity. Dedicated computer systems can be installed for this purpose, or a standard personal computer can be used with desired software and Internet access. Entertainment Centers Entertainment centers are available to provide an inhome theater. These are fully automatic and boast the best technology in picture and sound performance. Security Systems Home and business security systems that sound an alarm when opened can be installed indoors at doors Chapter 19: Electrical Plans and windows. Additional indoor motion sensors can sense movement inside the house when the system is activated. These security systems allow you to enter a special code at a control panel, allowing you to set the alarm when leaving, and to disarm the system when entering the house. Most systems have a night setting that allows you to arm the doors and windows but keep the motion sensors off when you are home and want the system active. Outdoor home or business security systems can also monitor the outside area. Most outdoor systems are programmed to turn on floodlights when movement is detected. Radio Frequency Systems Radio frequency (RF) systems are available that allow you to control a variety of lighting and mechanical applications throughout the home. Radio frequency is electromagnetic radiation waves that transmit audio, video, or data signals. The Federal Communication Commission (FCC) has defined RF ranges that can be used for wireless applications, such as those used in home systems. Home RF systems allow you to design options for specific lighting applications. For example, the RF system can control security lighting inside and outside the home by the press of a button within the home or from your vehicle as you approach the home. Other lighting schemes can also be designed that provide visibility or accent lighting to various areas of the home. You can control the lighting of hallways at night, or specific light dimming applications for accent purposes. Structured Wiring As home computer use and Internet access become common in nearly every home, structured wiring systems are part of the electrical work needed in the architectural design. Structured wiring systems are highspeed voice and data lines and video cables wired to a central service location. These wires and cables optimize the speed and quality of various communication signals coming into and going out of the house. This kind of wiring is typically used in commercial construction projects and is gaining popularity in residential design. In a system of this type, each electrical outlet, telephone jack, or computer port has a dedicated line back to the central service location. The central service location allows the wires to be connected as needed for a network configuration or for dedicated wiring from the outside. High-quality structured wiring systems use network connectors and parallel circuits, because conventional outlets and series circuits degrade the communication signal. A parallel circuit is an electrical circuit that contains two or more paths for the electricity or 435 signal to flow from a common source. A series circuit is a circuit that supplies electricity or a signal to a number of devices connected so that the same current passes through each device in completing its path to the source. Structured wiring systems allow the simultaneous use of a fax machine, a multiline telephone, and computers. Additional applications include digital satellite systems (DSS), digital broadcast systems (DBS), stereo audio, and closed-circuit security systems. ELECTRICAL DESIGN CONSIDERATIONS The discussion and many examples in this chapter provide you with the minimum requirements for the electrical design. You need to meet minimum code requirements while also considering the needs and preferences of the occupants. One way to design the electrical layout is to pretend that you are living in a home, or working in a commercial building, and plan a system based on your convenience and daily activities. The following list provides some of the basic design features to consider when creating the electrical plan. Entry. Every entry shall have at least one lighting outlet controlled by a switch on the inside of the building. There shall be at least one weatherproof GFCI outlet. Entry foyer. There is generally a light fixture centered in the entry foyer, with a single switch or two switches if necessary. Depending on the size of the foyer, there may be additional ceiling- or wall-mounted lighting outlets. The foyer should contain at least one duplex convenience outlet, with more spaced a minimum of 12' (3600 mm) apart if needed. Patios and porches. Patios and porches are generally designed with an entry and should have the same requirements. Additionally, these areas need adequate lighting. One lighting outlet per 150 sq ft (1394 sq m) should be considered. The number of duplex convenience outlets in an area depends on its use. A light fixture and weatherproof GFCI outlet should be placed at a sink, serving counter, or outside cooking area. Living area. Living rooms and great rooms should have at least one switch-controlled duplex convenience outlet. Additional outlets are needed for convenience and to meet code requirements. There is generally no central ceiling lighting outlet, but there are often accent lights such as recessed ceiling or wall lights. Dining room. Dining rooms and eating nooks should have a switch-controlled centrally located ceiling light. Outlets are needed for convenience and to meet code requirements. 436 Kitchen. The kitchen is a place where lighting and convenience outlets are very important. There should be switch-controlled centrally located lighting. Many designs use ceiling fluorescent fixtures or adequately spaced recessed ceiling lights. An additional switch-controlled light is often placed over the sink and other work areas. Small, high-intensity halogen recessed light fixtures are popular because they provide excellent illumination and are energy efficient. Fixtures are available with fixed and movable lights for directional applications. Available bulbs vary in the number of degrees of illumination provided, from a narrow directional effect to wide-angle lighting. The use of these light fixtures is not limited to the kitchen; they are effectively used in hallways and other rooms. Duplex convenience outlets should be placed at least 4' (1200 mm) apart, no more than 2' (600 mm) from a fixture or appliance, and with at least one outlet at each end of an island or peninsula. Each appliance should have a separate outlet. This includes the refrigerator, range, hood light and fan, oven, microwave, dishwasher, and trash compactor. There should also be additional small appliance outlets in every kitchen, pantry, breakfast room, dining room, or similar area. A switch-controlled garbage disposal can be used. Custom kitchens can also have under- and over-cabinet lighting and portable appliance compartments or garages. An exhaust fan vented to the outside is required. The exhaust fan can be in combination with a hood and light over the range or adjacent to the range. Bedrooms. Bedrooms often have a switch-controlled central ceiling light. Bedrooms can have a recessed ceiling light next to a wardrobe closet. The master bedroom can use a switch-controlled duplex convenience outlet rather than the ceiling light. Additional duplex convenience outlets should be spaced as desired or by minimum code requirements. Walkin wardrobes should have one or more switchcontrolled ceiling lights. Bathrooms. The bathrooms should have at least one lighting outlet in the ceiling or wall above the sink mirror. There should be one light over each sink and a GFCI outlet next to each sink, at 48" above the floor and not more than 36" from the edge of the fixture. Additional convenience outlets can be placed around the room to meet personal requirements. Outlets shall not be installed faceup in the work surface or cabinet top in a bathroom sink location. If fixtures are used in an enclosed shower or spa, they should be vapor proof. Ceiling lights are often recessed and should be placed in areas such as over Architectural Drafting and Design the water closet, tub, spa, or sauna as needed for adequate lighting. An exhaust fan that is vented to the outside is required, unless an operable window is used. Some owners prefer an exhaust fan even if an operable window is provided. Laundry/utility room. The laundry room should have at least one switch-controlled ceiling light, with other lights considered over work areas. Washer and dryer outlets are required along with adequate duplex convenience outlets. The appliance outlet cannot be more than 6' (1800 mm) from the appliance location. Office, recreation, or hobby room. An office or other auxiliary room should have ceiling lighting placed over planned work areas, and there should be duplex convenience outlets placed as needed for the intended purpose and to meet codes. If computers are used, dedicated outlets should be provided. Hallways. Ceiling lights should be placed no more than 12' (3600 mm) apart, with a switch controlling them from each end of the hall. Duplex convenience outlets should be at least 12' (3600 mm) apart. Stairs. Place at least one ceiling light at each floor or landing and have additional lights as needed to light the stairs adequately. Convenience outlets are not required but may be considered, especially if landings are involved. Garage. At least one ceiling outlet for every two cars, but one light per bay is better. Use at least one weatherproof GFCI duplex convenience outlet of 125-V, single phase, 15 to 20 amps. Provide additional outlets and lights as needed for work areas and other conveniences. An outlet and controls should be wired for every electric garage door opener. Outdoor outlets. At least one weatherproof outlet must be installed at the front and back of each home with direct access from grade and not exceed 6'–6" (1980 mm) above grade. Crawl spaces. All outlets in crawl spaces should be GFCI, 125-V, single phase, and 15 to 20 amps. Smoke detectors. Smoke detectors are required at each sleeping area and on each additional story and basement of a living unit. Smoke detectors are generally placed in the ceiling immediately outside the entrances to bedrooms or above stairs leading to adjacent bedrooms or living areas. The type of smoke detectors can be indicated in the specifications. Smoke detectors that are wired directly into the electrical system are preferred, and some installations use additional battery backup smoke detectors. Chapter 19: Electrical Plans Telephones. Careful consideration should be given to the locations where telephones are typically used. Common locations include the kitchen, master bedroom, laundry room, and office. Telephone jacks should be placed in every desired location or rough-wired for future installations. Rough-wire means to run wiring in the walls during construction for possible future hookup and use. Another term for rough-wired is pre-wired. Wiring during construction is always less expensive and easier than wiring after the building is occupied. Television, cable, stereo, security. Wiring for planned television, DVD, sound electronics, and security systems should be designed into the project. These items should also be pre-wired for installation during or after construction. The type of television wiring depends on the hookup to an antenna, cable, or satellite. The location of television outlets depends on the needs of the occupants, but outlets are generally provided in the living room, family room, recreation room, master bedroom, and in other rooms as needed. Sound electronics installations can be wired separately for sound throughout the home or associated with the cable television. The sound system can be connected to a central system with AM/ FM, CD, satellite radio, and other devices, and can be part of an intercom system. The security system should be wired throughout the building and should be designed in cooperation with a security expert to provide the best possible installation needed to meet the owner’s requirements. Security systems can be internal or connected to a monitoring station such as a private security provider or public police department. Computers and peripherals. Wiring for computers and peripherals is becoming an important part of the electrical system, as explained earlier in this chapter. Peripherals are items outside the main computer box. These items can include printers, modems, and fax machines. Refer to the earlier discussion covering home automation and structured wiring systems. SMOKE DETECTORS Smoke detectors and alarms provide an opportunity for safe exit through early detection of fire and smoke. A smoke alarm that meets the requirements of UL 217 (Underwriters Laboratories) must be installed per NFPA 72 (National Fire Protection Association) in each sleeping room, and at a point centrally located in a corridor that provides access to the bedrooms. 437 CARBON MONOXIDE ALARMS A carbon monoxide alarm is required in all new residential construction that contains fuel-fired appliances or has an attached garage. Alarms that meet UL 2034 must be placed outside of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units. Units must be installed in accordance with the manufacturer’s instructions. UNIVERSAL ELECTRICAL INSTALLATIONS The design of the electrical system to accommodate people of all ages and possible disabilities should be considered. The following are some possible considerations for these applications. Switch locations. Place light switches 2'−6" (760 mm) above the floor for easy use by children and people in wheelchairs. Additionally, provide an adequate turning radius next to the switch for wheelchair movement. More switches than what is considered normal should be considered for access by people with disabilities. Switches should be the type that operate by touch or can be sound- or motion-activated, and on a timer if necessary. A master switch that controls all of the lights in a home can be located in a convenient and commonly used place, such as in the master bedroom. See the earlier discussion covering radio frequency systems. Place the distribution panel in an easily accessible location and install the panel at a height lower than normal, such as 4'−6" (1320 mm), for wheelchair access. Convenience outlets. Bathroom vanity outlets should be placed in the side wall for easy access. Place outlets on the front or top surface of the base kitchen cabinets in convenient locations. Provide more than the normal number of outlets. For example, a spacing of 8' (2400 mm) is preferred over the code requirement of 12' (3600 mm). Outlets should be at least 15" (380 mm) above the floor rather than the normal 12" (300 mm). Determine the owner’s need for special medical equipment, communication systems, and emergency alarm circuits. Provide a special outlet in a ventilated area for a home owner to charge an electric wheelchair battery. Lighting. Provide specifications for wall-mounted lights to be placed within reach and ceiling fixtures that pull down for easy access from a wheelchair. Extra lighting should be considered, especially in locations where a person with disabilities might have difficulty seeing, such as a shower, bathroom, and 438 Architectural Drafting and Design D H F L ELECTRIC DOOR OPENER HEAT, LIGHT, FAN COMBINATION BELL SPECIAL INSTRUMENT SPECIFY TYPE, I.E., INTERCOM BELL/BUZZER M MOTOR P BUZZER CH PHONE CHIME R RADIO OUTLET CIRCUIT-BREAKER PANEL SD SMOKE DETECTOR, CEILING MOUNT CB RECESSED FLUSH MOUNT CB WALL MOUNT SD WALL MOUNT SPECIFY TYPE, I.E., INTERCOM WALL-MOUNTED LIGHT C CLOCK D DROP CORD S SWITCH LEG ELECTRICAL CIRCUIT, HIGH VOLTAGE THIN LINES CURVED OR STRAIGHT 3/16" TO 1/4" DASHES SWITCH LEG ELECTRICAL CIRCUIT, HIGH VOLTAGE THIN LINES CURVED OR STRAIGHT WITH LONG, 3/4" TO 1-1/2" AND TWO SHORT 3/16" TO 1/4" DASHES F TV ELECTRICAL CIRCUIT, HIGH VOLTAGE TV CABLE T.V. OUTLET PC PERSONAL COMPUTER CONNECTION T TRANSFORMER "T" IN CIRCLE = THERMOSTAT S STEREO SPEAKERS V FAN NOTE: VENT OUT IF REQUIRED SPECIAL PURPOSE COMMUNICATION OUTLET, SPECIFY TYPE VACUUM YARD LIGHTS MULTIPLE DUPLEX CONVENIENCE OUTLET S S3 S2 S T 4 DUPLEX CONVENIENCE OUTLET (WALL OUTLET) 110 VOLTS S OUTLET WITH SWITCH 110 VOLTS GFI R DOUBLE-POLE SWITCH THREE-WAY SWITCH SWITCH WITH TIMER CEILING-MOUNTED LIGHT SPLIT-WIRED OUTLET, WIRE TO SWITCH WP SINGLE-POLE SWITCH PS WEATHERPROOF OUTLET 110 VOLTS CEILING-MOUNTED LIGHT WITH PULL SWITCH (PS) CAN CEILING LIGHT FIXTURE SURFACE MOUNT FIXTURE. OUTLINE DENOTES FIXTURE SHAPE, USE DASH OUTLINES FOR RECESSED FIXTURES BATHROOM GROUND-FAULT CIRCUITINTERRUPTER 110 VOLTS (GFI OR GFCI) PS RANGE OUTLET 220 VOLTS WALL LIGHT OPTION WITH PULL SWITCH (PS) 220 220-VOLT OUTLET, USED FOR DOUBLE OVEN, DW FURNACE, ELECTRIC WATER HEATER, CLOTHES DRYER, SPA, WELDER; LABEL ITEMS FLOODLIGHTS SPECIAL CONNECTION FOR DISHWASHER, GARBAGE DISPOSAL (GD). HOT WATER HEATER (WH) FLUORESCENT LIGHT RECESSED FLUORESCENT LIGHT. THE FIXTURE OUTLINE DENOTES THE SIZE, PROVIDE NOTE SUCH AS 24" X 48" SINGLE SPECIAL PURPOSE OUTLET DOUBLE SPECIAL PURPOSE OUTLET CEILING SURFACE-MOUNT FLUORESCENT LIGHT CONTINUOUS LINE OF OUTLETS, DOUBLE OR SINGLE WITH ONE LINE EACH SIMPLIFIED FLUORESCENT LIGHT SOLID-SURFACE MOUNT DASHED RECESSED FLOOR OUTLET SINGLE FLOOR OUTLET DOUBLE J G J T JUNCTION BOX GENERATOR FIGURE 192 Common electrical symbols. S TRACK LIGHT UNDER-CABINET LIGHT WITH SWITCH 439 S3 S3 S3 S3 SINGLE-POLE SWITCH MAY BE CONNECTED TO ONE OR MORE LIGHTS. THREE-WAY SWITCH; TWO SWITCHES CONTROL ONE OR MORE LIGHTS. S4 Electrical symbols are used to show the lighting arrangement desired in the home. This includes all switches, fixtures, and outlets. All electrical symbols should be drawn with circles 1/8" (3 mm) in diameter, as seen in Figure 19-2. The electrical layout should be subordinate to the plan and should not clutter or detract from the other information. All lettering for switches and other notes should be 1/8" (3 mm) high, depending on space requirements and office practice. Switch symbols are generally drawn perpendicular to the wall and are placed to read from the right side or bottom of the sheet (see Figure 19-3). Also, notice that the switch relay should intersect the symbol at right angles to the wall, or the relay can begin next to the symbol. Verify the preference of your instructor or employer, and do not mix methods. Figure 19-4 shows several typical electrical installations with switches to light outlets. The switch leg or electrical circuit line is drawn using a curved dashed line. FOUR-WAY SWITCH; THREE SWITCHES CONTROL ONE OR MORE LIGHTS. S SINGLE-POLE SWITCH TO WALL-MOUNTED LIGHT. TYPICAL INSTALLATION AT AN ENTRY OR PORCH. S ELECTRICAL SYMBOLS S4 S4 kitchen. Provide extra lighting around stairs and landings. Additional lighting should be considered as occupants grow older. Lights can be controlled with dimmer switches as needed to provide varying intensity. Fluorescent lights should be avoided when designing a home for people with epilepsy, Alzheimer disease, hyperactivity, hearing aids, and cataracts. Specify natural light tubes when fluorescent lights are used. Track lighting should be considered when it is desirable to add or remove lights or change the angle of lights. Communications. Provide more than the normal number of telephone jacks when designing a home for people with disabilities. Also provide additional television and audio outlets if they are preferred by the owner. An intercom system is recommended for communication within the home. S Chapter 19: Electrical Plans SINGLE-POLE SWITCH TO SINGLE CEILING LIGHT. S S USE IRREGULAR (FRENCH) CURVE. S S VERTICAL WALL READ "S" FROM RIGHT S HORIZONTAL WALL READ "S" FROM RIGHT FIGURE 193 Placement of switch symbols. SINGLE-POLE SWITCH TO SPLIT-WIRED OUTLET. COMMON APPLICATION IN A ROOM WITHOUT A CEILING LIGHT. ALLOWS SWITCHING A TABLE LAMP. FIGURE 194 Typical electrical installations. 440 Architectural Drafting and Design VENT TO OUTSIDE AIR 48" T S F ● Placing switches or outlets on pocket doors, where they cannot be located due to the pocket door construction. ● Locating switches or outlets at a construction corner where a box cannot be installed. ● Drawing two or more circuit legs from a single switch. ● Placing a switch behind a door swing. ● Locating an outlet too far from a location where it is needed to operate a fixture, such as a desk. 24" X 48" OUTLET HEIGHT SPECIFIC NOTE FIGURE 195 Special notes for electrical fixtures. When a fixture with special characteristics is required, such as a specific size, location, or any other specification, a local note that briefly describes the situation is applied next to the outlet, as shown in Figure 19-5. Figure 19-6 shows common errors related to the placement and practice of electrical floor plan layout. The common errors encountered with electrical system design include: Figure 19-7 shows some examples of maximum spacing recommended for installation of wall outlets. Figure 19-8 shows examples of typical electrical layouts. Figure 19-9 shows a bath electrical layout. Figure 19-10 shows a typical kitchen electrical layout S S SWITCHES OR OUTLETS ON POCKET DOOR POOR S S GOOD S SWITCHES OR OUTLETS ON CORNER CONSTRUCTION POOR S S GOOD S 3 S3 POOR S3 GOOD S 3 FIXTURE SIZE POOR S GOOD S GOOD DESK GOOD FIGURE 196 Good and poor electrical layout techniques. SWITCH HIDDEN BEHIND DOOR POOR DESK POOR Chapter 19: Electrical Plans 441 WP GFCI 12' MAX. S S 6' MAX. 2' FIXED PANEL 12' MAX. FLOOR OUTLET 6' MAX. 12' MAX. 3 S 6' MAX. 12' MAX. S3 S3 S3 6' MAX. SHORT WALL OVER 36" LONG REQUIRES ONE OUTLET. FIGURE 197 Maximum spacing requirements. WP GFCI S VENT FAN TO OUTSIDE AIR GFCI 48" F H L S SS S 3 SD 3 3 3 S S S 3 SS FIGURE 198 Typical electrical layouts. 442 Architectural Drafting and Design EXHAUST FAN IS DESIRABLE BUT NOT REQUIRED WITH OPENABLE WINDOW WATERPROOF LIGHT IN SHOWER SS SS SS WP F VENT FAN TO OUTSIDE AIR 48" GFCI 48" GFCI F ENCLOSED BATH AREA REQUIRES EXHAUST FAN BATH VANITY WITH TWO SINKS REQUIRES TWO DUPLEX OUTLETS FIGURE 199 Bath electrical layout. 2' (610mm) 4' (1220mm) GFCI DW GD S GFCI S R 2' (610mm) 4' (1220 mm) MIN ALONG OPEN COUNTER OUTLET SPACING REFR 2' HOOD W/ LIGHT & FAN, VENT TO OUTSIDE AIR 48" X 72" LIGHT SOFFIT W/ 5-48" FLUORESCENT FIXTURES OR 6 EQUALLY SPACED HALOGEN RECESSED LIGHT FIXTURES S3 DBL OVEN BRM 3 S S PROVIDE SEPARATE CIRCUIT FOR MICROWAVE FIGURE 1910 Kitchen electrical layout. NOTE: AND FIXTURES TO BE GFCI CIRCUITS ALL KITCHEN LIGHTS Chapter 19: Electrical Plans 443 using fluorescent fixtures; however, small, high-intensity halogen recessed light fixtures are popular because they provide excellent illumination and are energy efficient. Placement of six or more of these recessed fixtures can provide quality lighting in this kitchen. Fixtures should be carefully placed to help reduce shadows at counter areas. LIGHT FIXTURES CEILING FLOOR LIGHT FIXTURE DESIGN AND PLACEMENT The content provided in this section was taken in part from the Grand Lighting Web site. Light fixture selection and placement is important to consider when designing a home. A variety of lighting methods and arrangements can be used to create a dramatic appearance, a soft feeling, the highlighting of artwork, or light for a work area. Consider the activities that take place and the desired visual effect when designing the lighting for different rooms in the home. Many types of lighting fixtures are available, including ceiling mounted, wall mounted, recessed, track, pendant, table lamp, floor lamp, and lighting with ceiling fans. The following describes a variety of lighting design options. Light fixtures can be purchased in high-voltage or low-voltage models. Low-voltage systems require transformers that reduce the voltage to the fixtures. A transformer is an electrical device that either raises or lowers the voltage of electricity. When installing low-voltage light systems, it is necessary to reduce the voltage to the fixtures from 120 volts to 12 volts, for example. General Lighting General lighting sets the basic ambient light level of a space, which is important for circulation and functionality. The following describes optional general lighting design applications. Ambient light is light that comes from all directions. Ceiling-mounted light fixtures are ideal for use in foyers, hallways, and bedrooms. Flush-mount are preferred on lower ceilings, whereas semi-flush lights are ideal on medium to high ceilings. Ceiling-mounted light fixtures or recessed light fixtures can be used in hallways. Hallway light fixtures should be centered on the hallway and spaced every 8' to 10' (2400 to 3000 mm) for full coverage. Additional lighting can be provided if necessary by spacing the light fixtures 4' (1200 mm) apart. Uniform Down-Lighting Uniform lighting provides a layer of ambient light typically used to provide general lighting on horizontal LIGHTING PATTERN FIGURE 1911 Uniform down-lighting. surfaces. Uniform lighting is commonly used to light an entire area, but typically has the least visual impact on a space. Figure 19-11 shows a typical uniform downlighting arrangement. Recessed lights are commonly used for down-lighting. Uniform lighting is often done with Parabolic Aluminized Reflector (PAR) or MR16 lamps spaced apart so their beams meet or overlap as desired. Spacing is a function of the selected lamp beam spread and the desired effect. PAR lights resemble car headlights. MR16 is a standard format for halogen reflector lamps made by a variety of manufacturers. MR16 lights are used for a variety of applications that require directional lighting of low to medium intensity, such as track lighting, recessed ceiling lights, desk lamps, pendant fixtures, landscape lighting, and retail display lighting. MR16 lamps are available in many power and beam combinations, other than those mentioned below. MR16 lamps are normally labeled according to the following beam spread abbreviations. The angles associated with these abbreviations vary depending on the manufacturer: ● ● ● ● ● ● ● VNSP (Very narrow spot): less than 8° NSP (Narrow spot): 8° to 15° SP (Spot): 8° to 20° NFL (Narrow flood): 24° to 30° FL (Flood): 35° to 40° WFL (Wide flood): 55° to 60° VWFL (Very wide flood): 60° or more Non-Uniform Down-Lighting Non-uniform down-lighting provides the appearance of pools of light and can give an interesting visual appearance. Recessed down-lights are commonly used for non-uniform down-lighting. Non-uniform downlighting is often done with PAR or MR16 lamps spaced far enough apart so their beams do not overlap as 444 Architectural Drafting and Design RECESSED LIGHT FIXTURE LIGHT FIXTURES LIGHT BEAM CEILING FLOOR LIGHTING PATTERN FIGURE 1912 Non-uniform down-lighting. INCORRECT CORRECT shown in Figure 19-12. A general recommendation is that recessed ceiling lights and track lights that illuminate pictures or artwork on a wall should be located at least 2' (600 mm) from the wall with a standard 8' (2400 mm) ceiling and, as the ceiling height increases, farther from the wall using the same ratio. For example, place the light fixtures 2'–6" (760 mm) from the wall for a 10' (3000 mm) ceiling, using this formula: 2/x : 8/10, 2x = (8)(10), 2x = 20, x = 2.5, 2.5 = 2'–6". The number of items and wall area to be illuminated also determine the light fixture spacing. In any given design, divide the wall length into equal spaces for light fixture placement. A wide variety of track and rail lighting is available for areas where recessed lighting is not practical, where flexibility in light placement is required, or where multiple lights are required in a small area. Task Lighting Providing supplemental lighting over a work area, such as a kitchen counter or desk, is important to allow enough light to perform the activity accurately, efficiently, and safely. Recessed Task Lighting Recessed down-lights are commonly used for work area lighting. For counter or work surface tasks, recessed fixtures should be placed between the cabinet face and the front edge of the counter. This position avoids casting of shadows as shown in Figure 19-13. When lighting work areas such as a desk or table, a vanity mirror, or over a sink, two down-lights should be placed above, slightly in front of the person, and on each side of the work area to provide overlapping light and minimize glare as shown in Figure 19-14. If possible, add complementary fill lighting from a diffuse source such as a wallmounted light fixture or an additional ceiling-mounted light fixture. FIGURE 1913 Recessed down-lights are commonly used for work area lighting. For counter or work surface tasks, recessed fixtures should be placed between the cabinet face and the front edge of the counter. This position avoids the casting of shadows. RECESSED LIGHT FIXTURE LIGHT BEAM CORRECT INCORRECT FIGURE 1914 When lighting work areas such as a desk or table, a vanity mirror, or over a sink, two down-lights should be placed above, slightly in front of the person, and on each side of the work area to provide overlapping light and to minimize glare. Decorative Pendant Task Lighting Decorative pendant lights provide both functional task lighting and add visual interest and aesthetic character to an area. A pendant light, sometimes called a drop or suspender, is a light fixture that hangs from the ceiling usually suspended by a cord, chain, or metal rod. Pendant lights are often used in multiples, hung in a straight line over kitchen countertops or islands, over a desk or other work area, over a dining or nook table, and sometimes in bathrooms. The bottom edge of the pendant lights should be mounted 30" to 36" (900 mm) above the countertop, island, or table. The light beam angle can be adjusted by using one of the available MR16 light bulbs. The light beam of multiple pendants can be designed apart or overlapping by changing the spacing of the fixtures (see Figure 19-15). Chapter 19: Electrical Plans 445 LIGHT BEAM LIGHT FIXTURES ratio between the ceiling light fixture location and the wall height is also shown in Figure 19-16. Accent Lighting of Three-Dimensional Objects FIGURE 1915 The pendant light beam angle can be adjusted by using one of the available MR16 light bulbs. The light beam of multiple pendants can be designed apart or overlapping by changing the spacing of the fixtures. Accent Lighting Accent lighting creates high contrast and focuses light on objects of interest such as paintings, sculptures, collectibles, and architectural details. For noticeable visual impact, accent lighting should be at least three times as bright as the surrounding area. Dramatic accent lighting requires contrast ratios of 5:1 or greater. Accent Lighting on Flat Artwork Flat artwork is usually lighted by a light source striking its surface at a 30° angle. This angle reduces glare, and prevents the casting of the viewer’s shadow onto the artwork. Figure 19-16 shows the recommended lighting for artwork hung at a typical height. The recommended LIGHT BEAM LIGHT FIXTURES Key lighting and fill lighting are effective ways to emphasize the three-dimensional character of an object such as a sculpture. This method involves the use of key and fill lighting from two sides of the object. Key lighting is a focused accent light used to create shadows and to highlight form and texture. Fill lighting is a soft light thrown from the opposite side of the object to soften the shadows, making the object appear natural. Other techniques can also be used to further accent the character of an object, such as silhouetting an object from behind. Wall Lighting The lighting of vertical surfaces can impact the perception of a space more than any other type of lighting. Light reflecting off of walls creates a bright, spacious feel and adds visual interest. Wall Wash Lighting Wall wash lighting provides even, diffuse lighting of vertical surfaces such as walls, large paintings, wall hangings, bookcases and shelving, cabinet fronts, or stairwells. The diffuse nature of wall wash lighting has the effect of flattening out textured surfaces. Diffuse lighting is light that is not concentrated in one place, and transmitted from a broad light source. Wall wash light fixtures are usually spaced apart equal to the distance from the wall. For example, a 10' (3000 mm) wide wall can have four ceiling recessed light fixtures spaced 24" (600 mm) apart and 24" out from the wall. Closer spacing leads to higher light levels with better lighting uniformity. As a general rule, wall wash lighting should be located at least 24" from the wall and spaced a minimum of 4' (1200 mm) apart. CEILING Graze Lighting 90° WALL Placing down-lights 6" to 12" (150 to 300 mm) from a wall provides a grazing effect where the light appears to scrape along the wall. Graze lighting can provide an accent to textured surfaces such as brick, stone, or stucco. PAR lamps are a good source to use for graze lighting. Light Scallop FIGURE 1916 The recommended lighting for artwork hung at a typical height, and the ratio between the ceiling light fixture location and the wall height. Light scallop is an effect created when the light fixture is placed close to the wall resulting in a concentrated arc-shaped light pattern on the wall. Light scallop can provide a dramatic effect, but can be an undesired effect when light fixtures are improperly placed. The intensity 446 Architectural Drafting and Design WALL 4' LIGHT BEAM LIGHT FIXTURES 2' 4' 50º 4' 50º FIGURE 1917 The spacing and distance from the wall, of the light fixtures, contributes to the scallop effect. of the scallop can be increased or decreased by the type of fixture and light source used. A diffused light source creates a soft scallop and an intense-focused light source creates a bright scallop. The light fixtures’ spacing and their distance from the wall also contribute to the scallop effect as shown in Figure 19-17. Locating Recessed Lighting Recessed light fixtures can be installed only where there is enough space to accommodate the housing. The housing is the box that contains the recessed light wiring, can, trim, and bulb. The can is the generally cylindrical unit containing the light fixture and bulb. The can is usually finished white, black, chrome, or brass and has a trim piece that covers the ceiling cutout. Recessed light fixtures can generally be installed between the joist spaces of multistory houses. Recessed fixtures cannot be located at a ceiling joist, corner, or exterior wall where rafters reduce the space available. Recessed light housings must be a minimum of 3" away from insulation or flammable material, unless an insulation contact (IC) housing is used. A heat-barrier housing cover may be required where blown-in insulation is used. REFLECTED CEILING PLANS A reflected ceiling plan (RCP) is a drawing that shows the features located on the ceiling of a room or space. A reflected ceiling plan gets its name from a view of the ceiling as if it is reflected onto a mirror on the floor. This way the reflected ceiling plan has the same orientation as its related floor plan. A reflected ceiling plan can be found in a set of construction drawings for a house or business. Interior designers often draw reflected ceiling plans when designing spaces. Interior designers and architects draw reflected ceiling plans and send the drawing to an electrical consulting engineering firm, where the electrical circuitry, fixtures, and other electrical applications are designed to comply with local building codes, electrical codes, and fire codes. An RCP typically contains ceiling construction and finish sections, details, and specifications. An RCP also shows special ceiling features, such as entertainment, sound, and communication system wiring and speaker locations, emergency lighting, exit signs, security devices, smoke and fire alarm placement, exhaust fans, and heating lamps. An RCP can display the heating, ventilation, and air-conditioning (HVAC) system, providing returnair grills and supply-air diffusers. Some RCP drawings show fire sprinkler head locations. Similar to the electrical plan described throughout this chapter, RCP drawings can include electrical circuit layout with the power panel, and lighting fixture and switch locations with circuit runs. The RCP drawing normally includes electrical specifications and an electrical symbol legend similar to the example shown in Figure 19-22. When an RCP is created for a commercial building, it can be referred to as a ceiling panel plan. The ceiling panel plan is generally designed as a grid of 24" × 48" (600 × 1200 mm) rectangles representing suspended or drop ceiling panels and light fixtures. The terms suspended and drop ceiling have the same meaning—a finish ceiling constructed of lightweight ceiling panels and light fixtures hung from cables, wires, or brackets from the structure above. The lighting fixtures are generally fluorescent fixtures that fit exactly into the drop-ceiling modules in desired locations for providing the needed lighting. See Chapter 44 for additional information regarding reflected ceiling plans. ELECTRICAL SCHEDULES Schedules are described in detail in Chapter 16. Electrical fixtures can be identified in schedules, notes, descriptions of materials, or in specifications. Lightfixture schedules typically provide fixture symbol, manufacturer’s name, type, color, bulb, wattage, and remarks columns. Light fixtures are identified in a schedule by placing a letter or number key next to the floor plan symbol and correlating the same letter or number to the schedule, or fixtures can be correlated by room name in which the fixtures are located. Chapter 19: Electrical Plans 447 FIGURE 1918 Sample electrical fixture schedule. Electrical circuit schedules can be used to provide electrical panel, circuits, poles, and amperage requirements and specifications. An electrical panel schedule can be used to provide panel size and type, main circuit size and type, panel manufacturer and model, and wiring specifications. Figure 19-18 shows a typical light fixture schedule. ELECTRICAL WIRING SPECIFICATIONS The following specifications describing the installation of the service entrance and meter base for a residence have been adapted from information furnished by Home Building Plan Service, Inc. Service Entrance and Meter Base Installation Before the installation of the service entrance and meter base, the following questions must be resolved: 1. What is the service capacity to be installed? For capac- ity of service, the average single-family residence should be equipped with a 200-amp service entrance. If heating, cooking, water heating, and similar heavy loads are supplied by energy sources other than electricity, the service entrance conductors can be sized for 100 amps, provided that local codes are not violated. Some local codes require a minimum capacity of 200 amps for each single dwelling. Local inspection authorities and the power company serving the area can be of assistance if difficulty is encountered in sizing the service entrance. 2. Where is the service entrance to be located? The service entrance location depends on whether the power company serves the houses in the area from an overhead or underground distribution system. The underground service entrance is the most desirable from the standpoint of aesthetics and reliability. However, if the power company services the area from an overhead pole line, an underground service entrance may be impractical, prohibitively expensive, or even impossible. A combination of overhead and underground service is an option in some cases. This is possible where overhead service is provided to a specific location, such as the property line, and an underground service is provided for the remaining distance to the house. 3. Where will the meter base be located? The meter base must always be mounted so the meter socket is on the exterior of the house, preferably on the side wall of a garage. For aesthetic reasons, the meter base should not be installed on the front of the house. If the house does not have a garage, the meter base should be located on an exterior side wall as near as practical to the distribution panel. 4. Where will the distribution panel be located? The preferred location for the distribution panel is on an inside garage wall, close to the heaviest electrical loads, such as a range, clothes dryer, or electric furnace. The panel should be mounted flush unless the location does not permit a flush mount. If the house does not have a garage, the panel should be located in a readily accessible area such as a utility room or kitchen wall. In some localities the electrical power billing structure requires two meters. For example, lighting and general-use energy may be billed at a rate different from energy used for space and heating water. In such a 448 Architectural Drafting and Design situation, provide two meter bases and two distribution panels to suit requirements. METRICS IN ELECTRICAL INSTALLATIONS Electrical conduit designations are expressed in millimeters. Electrical conduit is a metal or fiber pipe or tube used to enclose a single or several electrical conductors. Electrical conduit is produced in decimal inch dimensions and is identified in nominal inch sizes. Nominal size is referred to as the conventional size; for example, a .500" pipe has a 12" nominal size. The actual size of a conduit remains in inches but is labeled in metric: Inch Metric (mm) Inch Metric (mm) 1/2 16 2 1/2 63 3/4 21 3 78 1 27 3 1/2 91 1 1/4 35 4 103 1 1/2 41 5 129 2 53 6 155 Existing American Wire Gauge (AWG) sizes remain the same without a metric conversion. The diameter of wires conforms to various wire gauge systems. The AWG is one system for the designation of wire sizes. Wire gauge is a method of defining wire diameter by a number, with wire diameter increasing as the number gets smaller. STEPS IN DRAWING THE ELECTRICAL PLAN The electrical plan is prepared as a separate floor plan drawing, labeled ELECTRICAL PLAN, for complex homes, or combined with all other floor plan information for basic homes. When drawing the electrical plan with all other floor plan information, follow the next steps after placing everything on the drawing, as explained in Chapter 18. If you are creating a separate electrical plan, draw the plan as described in the following steps and use the CADD layering system as needed. To do this, first begin with a base drawing of the floor plan, with all of the walls, doors, windows, stairs, cabinets, and the fireplace. The basic room titles are optional. A base drawing for the model CADD APPLICATIONS CADD electrical symbol libraries provide quick insertion of these symbols. When a CADD system is used, each symbol and feature on the electrical plan can be placed on an individual layer. If you are using the American Institute of Architects (AIA) layering system, the layer names given in the following table can be applied to your electrical plan. ■ Layer Name Description E-LITE Lighting system E-POWR Power E-CONT Controls and instrumentation E-GRND Ground system E-AUXL Auxiliary systems E-LTNG Lightning protection system E-FIRE Fire protection system E-COMM Telephone communications E-DATA Data and local area network (LAN) systems E-SOUN Sound system E-CABL Cable system E-CCTV Closed-circuit television E-NURS Nurse call system E-INTC Intercom and PA system E-PGNG Paging system E-BELL Bell system E-CLOK Clock system Chapter 19: Electrical Plans home that was first used in Chapter 18 is shown in Figure 19-19. Draw all light fixtures. Use 1/8" (3 mm) diameter circles for the light fixture symbols, which is 6" at a scale of 1/4" = 1'−0" (150 mm at 1:50). Refer to Figure 19-20. If electrical symbols are too large, they distract from the appearance of the drawing. If they are too small, they are difficult to read. STEP 1 Place all electrical outlets, such as duplex convenience, range, television, clock, and junction boxes. Figure 19-20 shows the placement of items for Step 2. STEP 2 Draw all additional electrical symbols including doorbells, smoke detectors, fans, and power panels (see Figure 19-20). STEP 3 Letter all switch locations and provide switch characteristics, such as three-way switches (see Figure 19-20). When possible, use 1/8" (3 mm) high text when adding information to symbols. You can use 3/32" (2.5 mm) high text if space is limited, such as the number 3 placed next to a three-way switch symbol. Confirm this practice with your course or company standards. STEP 4 Draw electrical circuits or switch legs from switches to fixtures using a dashed arc line as shown in Figure 19-21. STEP 5 Letter all notes, and the drawing title and scale, as shown in Figure 19-21. STEP 6 This is the step where you can add general electrical notes, fixture schedules, and symbol legends. These items should be placed on the same drawing as the electrical plan when possible. There is not enough space on the sheet with the main floor electrical plan to place these items for the model house. These items are located on the upper floor electrical plan for the model house, which is described in the following section. STEP 7 DRAWING THE UPPER FLOOR ELECTRICAL PLAN Use the same steps to draw the electrical layout for the upper floor plan. Figure 19-22 shows the upper floor electrical plan for the model home. Notice in Figure 19-22 that the general electrical notes and the electrical symbol legend features are placed in the drawing with the electrical floor plan. Not all offices display an electrical symbol legend, because standard symbols are typically used, which normally do not 449 require identification. This is also a good location for electrical fixture schedules or other electrical-related schedules. There are no electrical schedules for the model house. ELECTRICAL PLAN DRAWING CHECKLIST Check off the items in the following list as you work on the electrical plan, to be sure that you have included everything necessary: ❑ Switch locations labeled with proper placement and identification, such as three-way, four-way, or dimmer. ❑ Inside and outside light fixture locations. ❑ Recessed light fixture locations. ❑ Fluorescent light fixtures in 24" (600 mm) modules, where used. ❑ Switch legs drawn with dashed lines. ❑ Duplex convenience outlets located based on code requirements. ❑ Kitchen and bath GFCI outlets. ❑ Exterior duplex convenience outlets, specifying weatherproof and GFCI. ❑ Outlets for refrigerator, microwave on a separate circuit, garbage disposal with switch, dishwasher, trash compactor, clothes washer. ❑ Exhaust fans. ❑ Smoke detectors. ❑ Utility and appliance outlets: Furnace, clothes dryer, range, ovens, and water heater shown and labeled. Outlets are 200-V for electric appliances as needed, or gas and 110-V outlets. ❑ Garage door junction boxes with switches for automatic door openers. ❑ Television, telephone, separate Internet jack, and computer outlets shown and labeled on separate circuits. ❑ Vacuum system outlets located and labeled. ❑ Circuit panel location, and specifications. ❑ Door buzzer and chime location. ❑ Smoke detectors at each bedroom or sleeping area. ❑ Review all specific notes. ❑ General notes. ❑ Drawing title and scale. ❑ Title block information. 450 UP 1'-6" UTILITY DINING FAMILY SHOP 9'-5" X 7'-1" 12'-6" X 11'-5" 17'-4" X 11'-5" 17'-0" X 11'-5" LINE OF UPPER FLOOR PANTRY LINE OF 7'-0" CLG DN 7 1/2" BATH UP 1'-2" GARAGE 22'-5" X 23'-4" ENTRY FIGURE 1919 Base sheet for the floor plan used in Chapter 18. 12'-9" X 15'-4" DW GD TC UP 1'-6" COVERED PORCH LS Architectural Drafting and Design LINE OF UPPER FLOOR DN 7 1/2" LINE OF 7'-0" CLG 34" RAIL LIVING 12'-11" X 15'-4" UP 14R KITCHEN S&P CLOSET GFCI WP UTILITY 9'-5" X 7'-1" GFCI DINING FAMILY Chapter 19: Electrical Plans UP 1'-6" GFCI SHOP 12'-6" X 11'-5" 17'-4" X 11'-5" 17'-0" X 11'-5" GFCI LINE OF UPPER FLOOR LINE OF 7'-0" CLG DN 7 1/2" 3 TV 3 72" 3 GFCI BATH LF GFCI 3 LINE OF UPPER FLOOR GFCI WP 3 GARAGE 22'-5" X 23'-4" GFCI GFCI GFCI DW J GFCI GD TC GFCILS J J 3 3 GFCI GFCI 3 DN 7 1/2" ENTRY UP 1'-2" 12'-9" X 15'-4" S&P CLOSET LINE OF 7'-0" CLG 34" RAIL UP 14R LIVING 3 GFCI KITCHEN SD 12'-11" X 15'-4" GFCI WP 3 C 3 PANTRY TV CLG DOOR OPENER CLG DOOR OPENER UP 1'-6" COVERED PORCH GFCI FIGURE 1920 Step 1: Draw all light fixtures. Step 2: Place all electrical outlets, such as duplex convenience, range, television, clock, and junction boxes. Step 3: Draw all additional electrical symbols including doorbells, smoke detectors, fans, and power panels. Step 4: Letter all switch locations and provide switch characteristics, such as three-way switches. 451 452 UP 1'-6" GFCI WP UTILITY 9'-5" X 7'-1" GFCI DINING FAMILY GFCI SHOP 12'-6" X 11'-5" 17'-4" X 11'-5" 17'-0" X 11'-5" GFCI LINE OF UPPER FLOOR LINE OF 7'-0" CLG DN 7 1/2" 3 TV 3 72" 3 GFCI BATH LF GFCI 3 GD J RANGE & HOOD W/LIGHT & FAN VENT TO OUTSIDE AIR GFCI GFCI TC LS GFCI J CLG DOOR OPENER CLG DOOR OPENER UP 1'-6" COVERED PORCH GFCI MAIN FLOOR ELECTRICAL SCALE: 1/4" = 1'-0" FIGURE 1921 Step 5: Draw electrical circuits or switch legs from switches to fixtures using a dashed arc line. Step 6: Letter all notes, and the drawing title and scale. Architectural Drafting and Design LINE OF UPPER FLOOR GFCI WP 3 DW J GARAGE 22'-5" X 23'-4" 3 3 GFCI GFCI GFCI GFCI 3 DN 7 1/2" ENTRY UP 1'-2" 12'-9" X 15'-4" S&P CLOSET LINE OF 7'-0" CLG 34" RAIL UP 14R LIVING 3 GFCI KITCHEN SD 12'-11" X 15'-4" GFCI WP 3 C 3 PANTRY TV BATH BED#1 12'-11" X 19'-3" LF H SD BED#2 10'-10" X 11'-5" GFCI 3 24" X 36" OPENABLE INSULATED TEMP GLASS SKYLIGHT 7. 3 LINEN 36" RAIL GFCI 34" RAIL DN 14R 3 3 3 SD 22" X 30" ATTIC ACCESS WP S&DBL P S&P CLOSET BED#3 S&P SD 8. 9. 10. 11. 12. BATH 30" WIDE KNEE SPACE S&P CLOSET S&P 10'-10" X 11'-9" LF WALK-IN CLOSET 3. 4. 5. 6. SD TV 2. GFCI 24" X 24" DBL INSULATED TEMP GLASS SKYLIGHT GFCI 13. 14. 15. UPPER FLOOR ELECTRICAL ALL GARAGE AND EXTERIOR PLUGS AND LIGHT FIXTURES TO BE ON GFCI CIRCUIT. ALL KITCHEN PLUGS AND LIGHT FIXTURES TO BE ON GFCI CIRCUIT. PROVIDE A SEPARATE CIRCUIT FOR MICROWAVE OVEN. PROVIDE A SEPARATE CIRCUIT FOR PERSONAL COMPUTER. VERIFY LOCATION WITH OWNER. VERIFY ALL ELECTRICAL LOCATIONS W/ OWNER. EXTERIOR SPOTLIGHTS TO BE ON PHOTOELECTRIC CELL W/ TIMER. ALL RECESSED LIGHTS IN EXTERIOR CEILINGS TO BE INSULATION COVER RATED. ELECTRICAL OUTLET PLATE GASKETS SHALL BE INSULATED ON RECEPTACLE, SWITCH, AND ANY OTHER BOXES IN EXTERIOR WALL. PROVIDE THERMOSTATICALLY CONTROLLED FAN IN ATTIC WITH MANUAL OVERRIDE. VERIFY LOCATION WITH OWNER. ALL FANS TO VENT TO OUTSIDE AIR. ALL FAN DUCTS TO HAVE AUTOMATIC DAMPERS. HOT WATER TANKS TO BE INSULATED TO R-11 MINIMUM. INSULATE ALL HOT WATER LINES TO R-4 MINIMUM. PROVIDE AN ALTERNATE BID TO INSULATE ALL PIPES FOR NOISE CONTROL. PROVIDE 6 SQ FT OF VENT FOR COMBUSTION AIR TO OUTSIDE AIR FOR FIREPLACE CONNECTED DIRECTLY TO FIREBOX. PROVIDE FULLY CLOSABLE AIR INLET. HEATING TO BE ELECTRIC HEAT PUMP. PROVIDE BID FOR SINGLE UNIT NEAR GARAGE OR FOR A UNIT EACH FLOOR (IN ATTIC). INSULATE ALL HEATING DUCTS IN UNHEATED AREAS TO R-11. ALL HVAC DUCTS TO BE SEALED AT JOINTS AND CORNERS. Chapter 19: Electrical Plans ELECTRICAL NOTES 1. SCALE: 1/4" = 1'-0" ELECTRICAL LEGEND 110 VOLT DUPLEX CONVENIENCE OUTLET GFCI GFCI WP TV CLOCK OUTLET CIRCULAR RECESSED LIGHT 110 VOLT GROUND FAULT CIRCUIT INTERRUPT DUPLEX OUTLET DOORBELL SQUARE RECESSED LIGHT 110 VOLT WATERPROOF GFCI DUPLEX OUTLET SINGLE-POLE SWITCH LF LIGHT, FAN COMBINATION THREE-WAY SWITCH LF H LIGHT, FAN, HEAT COMBINATION 220 VOLT OUTLET CEILING-MOUNTED LIGHT SD CEILING-MOUNTED SMOKE DETECTOR JUNCTION BOX WALL-MOUNTED LIGHT CABLE TELEVISION OUTLET FLUORESCENT LIGHT 110 VOLT SPLIT-WIRED OUTLET J C 3 SD WALL-MOUNTED SMOKE DETECTOR 453 FIGURE 1922 The upper floor electrical plan for the model home used in this textbook. 454 Architectural Drafting and Design CADD APPLICATIONS Drawing Electrical Symbols with CADD As floor plans are generated for construction documents, other plans may be needed to complete the construction set of working drawings. In both residential and commercial applications, the addition of an electrical plan is normally required. Many companies provide two separate drawings for residential and commercial projects. One drawing is the floor plan completely dimensioned, and the other drawing is a floor plan that includes the walls, doors, and windows with electrical symbols added. In many cases, a base floor plan drawing is used as an underlay, and then electrical symbols are drawn over the top creating a composite electrical plan drawing. In architectural CADD programs, you can select symbols from pull-down menus, icon menus, dialog boxes, and tablet menus. These software programs provide you with maximum variety and flexibility to create a high-quality electrical plan in an efficient manner. Figure 19-23 displays examples of standard electrical symbols used in architectural projects, and Figure 19-24 shows a typical electrical plan for a residence. Most of the common electrical symbols are provided with the software of many of the CADD programs. When these symbols are available, you select the desired symbol from a menu, dialog box, palette, or library and insert the symbol into position on the drawing. In the event that a desired electrical symbol is not available, you are often given tools to create custom electrical symbol libraries. Parametric design plays an important role in applications such as ceiling lighting grids. In these types of programs, you specify the room width, length, ceiling height, and grid size. The computer then automatically draws the entire ceiling grid. After the ceiling grid is in position, lighting fixtures can be assigned. In the event of a design change, such as the repositioning of the ceiling grid, a height change to the grid, or a room size change, the lighting fixture symbols attached to the ceiling grid are automatically adjusted, greatly reducing the amount of time it takes to revise the drawing. AutoCAD, for example, includes a powerful drawing information manager called DesignCenter. A number of symbol libraries are installed with AutoCAD that are available as drawing (.dwg) files. Numerous different files contain architectural symbols and other types of content. The symbols in each library can be accessed in DesignCenter and dragged and dropped into your drawing. Revit, an Autodesk, Inc. product, is architectural modeling software that also includes a number of parametric electrical symbols. These parametric symbols understand when they are attached to ceiling and wall objects. If the ceiling or wall objects are modified, the electrical symbols react to the changes such as moving with the wall or ceiling. There are also a number of online resources with electrical symbols in different CADD file formats for use in your floor plans. ■ COMM_TV V CONNECTION STARTER T - COMBO TV CEILING FFAN 42 COMM_TV STARTER T - MAGNETIC S COMM_SPEAKER STARTER T - MANUAL T TV Access Panel EXIT SIGN EXIT DIR FLUOR_1X4 EXIT_WALL W MOUNT COMM_PHONE JACK 2 COMM_PHONE JACK B COMM_BELL FLUOR_2X2 FLUOR_1X4 NIGHT FLUOR_1X4 EMERGENCY FLUOR_2X2 NIGHT POWER_PANEL P FLUOR_1X8 Fan PANEL BOARD P H Power_220 Recpt FLUOR_1X8 NIGHT FLUOR_1X8 EMERGENCY SMOKE DETECTOR T THERMOSTAT A Power_Quad Recep J JUNCTION BOX - ROUND TRACK_5 HEAD - 12FT INC_EMERGENCY - WALL W J JUNCTION BOX - SQUARE TRACK_4 HEAD - 10FT INC_WALL W MOUNT D DIMMER CB CIRCUIT BREAKER B BUZZER TRACK_3 HEAD - 6FT BELL TRACK_3 HEAD - 4FT HORN INC_EMERGENCY INC_ROUND SWITCH_SINGLE POLE INC_EMERGENCY - SQUARE 2 SWITCH_DIMMER INC_EMERGENCY - SQUARE 1 SWITCH_3 - WAY A INC_EMERGENCY - ROUND SWITCH_4 - WAY A FIGURE 1923 Examples of electrical symbols used in CADD drawings. FLUOR_2X2 EMERGENCY FLUOR_2X4 Power_Duplex Recpt B SD HEAT DETECTOR SPECIAL CONNECTION H INC_CEILING E CEILING FFAN 48 FLUOR_2X4 NIGHT TRACK_4 HEAD - 8FT TRACK_2 HEAD - 3FT FLUOR_2X4 EMERGENCY Chapter 19: Electrical Plans 455 CADD APPLICATIONS WP sss F s BEDROOM REC. ROOM F T ss s s s S SD SD T TV F F 110V QUAD RECEPTA T CLE 220V RECEPTA T CLE LIGHT FIXTURE RECESSED LIGHT SMOKE DETECTOR TELEPHONE JACK CABLE TELEVISION JACK FAN F FAN/LIGHT FIXTURE WET BAR ss s s SINGLE-POLE SWITC I H THREE-WAY W SWITCH FOUR-WAY W SWITCH SWITCH WITH DIMMER SWITCH WITH TIMER 110V DUPLEX RECEPTA T CLE A COVER W 110V WITH WEATHERPROOF WP L INTERRUPT CIRCUIT GFI 110V ON GROUND FAULT FLOOR DUPLEX RECEPTA T CLE SPLIT-WIRED RECEPTA T CLE s ELECTRICAL INDEX s s3 s4 sD sT BEDROOM T F s s ss3 ss s s s T s ss 3 DEN GARAGE S SD WP MAIN FLOOR ELECTRIC PLAN SCALE: 1/4" = 1'-0" FIGURE 1924 Sample electrical plan for a residence. Courtesy Ron Palma, 3D-DZYN. 456 GOING GREEN Electricity Generation from Wind Power The following information was taken in part from the Southwest Windpower Web sites located at www.windenergy.com, and www.skystreamenergy. com. Skystream 3.7, developed by Southwest Windpower in collaboration with the U.S. Department of Energy’s National Renewable Energy Laboratory (NREL), is the newest generation of residential wind technology. Skystream is the first fully integrated small wind generator designed specifically for the utility grid– connected market. AWARD-WINNING TECHNOLOGY Skystream 3.7 was named a 2007 Top Green Building Product by Sustainable Industries, a magazine for green business leaders. Skystream was also awarded a 2006 Best of What’s New Award from the editors of Popular Science and was included in TIME magazine’s 2006 Best Inventions. RESIDENTIAL WIND POWER ELECTRICITY GENERATION Skystream is the first all-inclusive wind generator with built-in controls and inverter designed specifically for utility grid–connected residential and commercial use. This small wind generator allows home and business owners to harness the free power of the wind and take control of their energy bills like never before. Early adopters have reported a savings of more than 50% on their energy bills. The Skystream 3.7 is shown in Figure 19-25. Specifically for Grid-Connectivity The Skystream is specifically designed for utility grid– connected homes and businesses. In certain states, consumers can take advantage of “net-metering,” which is the sale of unused energy back to the power grid as shown in Figure 19-26. How the Skystream Works Skystream offers a simple, all-in-one solution for harnessing wind energy on a residential scale. Different from all other technologies, Skystream 3.7 is the first all-inclusive wind generator with built-in controls and an inverter. An inverter is an appliance used to convert independent DC power into standard household AC current. During installation, the Skystream is connected to the electric meter, and nothing else changes inside the home. The Skystream works together with the electric utility to power the FIGURE 1925 The Skystream 3.7 is the first residential, utility grid–connected small wind power turbine designed for residential use and commercial applications. Courtesy Southwest Windpower. home or business. When the wind is not blowing, electricity is supplied by the utility company. When there is wind, the Skystream provides clean, quiet electricity. When the Skystream generates more electricity than needed, the meter can actually spin backwards, which means you are selling electricity back to the utility company. Energy Production in Exceptionally Low Wind Speeds Designed for low wind speeds, Skystream 3.7 has a 2.4 kW rating and begins producing power in an 8 mph (3.5 m/s) breeze with full output achieved at 20 mph (9 m/s). Determine the average wind speed in your area by going to www.windenergy.com/globalwindmaps/ united_states.htm. Low Profile Skystream was designed to blend in with its surroundings. When mounted on towers ranging from 33' to 60' (10.6 to 457 GOING GREEN Electricity Generation from Wind Power (Continued) Disconnect Switch Meter Skystream provides electricity to home Home connected to utility grid FIGURE 1926 How the Skystream 3.7 wind power electricity generator works. Courtesy Southwest Windpower.r 18.3 m), it has little visual or audible impact on its surroundings. Towers up to 110' (33.5 m) are also available. A site assessment is important to determine the best tower height for your specific site locations. Quiet Operation The Skystream is exceptionally quiet during operation. In fact, Skystream’s sound is unrecognizable over trees blowing in the wind. The sound pressure level generated by Skystream is in the range of 40 to 50 decibels, which is quieter than background noise in a home or office. RESIDENTIAL WIND POWER INSTALLATION Southwest Windpower recommends installing Skystream 3.7 at sites with the following criteria: • Adequate wind resource. Minimum average wind speed for Skystream 3.7 is 10 mph (4.5 m/s). Ideal sites have 12 mph (5.4 m/s) average wind or greater. • Site free from obstructions. Clean, unobstructed wind is best for Skystream 3.7. The top of the tower should be a minimum of 20' (6 m) above any surrounding object within a 300' (91.5 m) radius. Although the machine can be installed on smaller lots of land, properties of 1 acre or more are typically ideal and generally have unobstructed wind. • Suitable zoning. Tower installation must comply with local zoning regulations. It is also advisable to make sure there are no Home Owner Association (HOA) regulations that prohibit the use of towers. • Interconnection with utility. The local utility must allow for interconnection. The 1979 federal Public Utility Regulatory Policies Act (PURPA) requires that small systems be allowed to connect to the electrical grid, but home owners should consult their local utility. • Electricity cost of $0.10/kWh or greater. Consumers should consult with their local utility or look at their electric bill. REMOTE WIND POWER GENERATOR INSTALLATIONS The Southwest Windpower Whisper and Air series generators provide dependable energy for remote homes, telecommunications sites, water pumping, and other rural applications in moderate to extreme environments. Whisper generators provide direct current to batteries, which store the energy until it is needed. Standard residential alternating current appliances can be used if the power is run through an inverter before use. The Air series generator incorporates a microprocessor-based technology for increased performance, improved battery charging capability, greater reliability, and reduced noise. Figure 19-27 shows how the remote wind power electric generator works. 458 GOING GREEN Electricity Generation from Wind Power (Continued) Wind generator PV array Batteries provide electricity to home Inverter Battery bank Whisper charge controller Whisper provides electricity to batteries PV panels provide electricity to batteries FIGURE 1927 How the remote wind power electric generator works. Courtesy Southwest Windpower. TAX INCENTIVES FOR WIND POWER GENERATORS Depending on the tower and installation costs, wind speed average, rebates, and local electricity costs, the Skystream 3.7 can pay for itself in as little as five years. On October 3, 2008, the Emergency Economic ADDITIONAL RESOURCES See CD for more information The following Web sites can be used as a resource to help you research available products and floor plan design options. These Web site links are also provided on the Student CD where you can select a link and go automatically to the specified Web site. Address www.avnow.com www.broan.com www.nutone.com Stabilization Act of 2008, HR 1424, was passed, which included a new federal-level tax credit for qualified small wind turbines including consumers who purchase Skystream 3.7. Check with your tax advisor to confirm the availability in your area. Company, Product, or Service Audio video environments Bath fans Central cleaning systems, intercoms www.beamvac.com www.homedepot.com www.lowes.com www.squared.com www.caddepot.com www.catalog.com www.leviton.com Central vacuum systems Electrical fixtures Electrical fixtures Electrical systems For use in assembling CADD symbol libraries For use in assembling CADD symbol libraries Lighting controls Chapter 19: Electrical Plans 459 www.grandlighting.com/design www.lutron.com www.skystreamenergy.com Lighting design and placement RadioRA, home lighting control system www.windenergy.com www.alcatel-lucent.com www.onqtech.com Skystream 3.7 small wind generator Southwest Windpower Wiring systems Wiring systems See CD for more information Electrical Plans Test QUESTIONS DIRECTIONS: Answer the following questions with short, complete statements or drawings as needed on an 8 1/2" × 11" sheet of notebook paper, or complete the electronic chapter test on the Student CD. 1. Letter your name, Chapter 19 Test, and the date at the top of the sheet. 2. Letter the question number and provide the answer. You do not need to write the question. Answers can be prepared on a word processor if approved by your course guidelines. Question 19–1 Duplex convenience outlets in living areas should be a maximum of how many feet apart? Question 19–2 Duplex convenience outlets in living areas should be no more than how many feet from a corner? Question 19–3 Describe at least four energy-efficient considerations related to electrical design. Question 19–4 Draw the proper floor plan symbol for: a. Duplex convenience outlet b. Range outlet c. Recessed circuit breaker panel d. Phone e. Light f. Wall-mounted light g. Single-pole switch h. Simplified fluorescent light fixture i. Fan Question 19–5 Why is it poor practice to place a switch behind a door swing? Question 19–6 What is a GFCI duplex convenience outlet? Question 19–7 The average single-family residence should be equipped with how many amps of electrical service? Question 19–8 Define outlet box. Question 19–9 When does rough-in of electrical wiring take place? Question 19–10 Define outlet. Question 19–11 Define lighting outlet. Question 19–12 What is the code requirement for the spacing of outlets in a kitchen? Question 19–13 Give two possible abbreviations for the ground fault circuit interrupter. Question 19–14 Define structured wiring systems. Question 19–15 Where are smoke detectors required? PROBLEMS Problem 19–1 Draw a typical floor plan representation of the following: a. Three-way switch controlling three ceiling- mounted lighting fixtures b. Four-way switch to a one ceiling-mounted lighting fixture c. Single-pole switch to a wall-mounted light fixture d. Single-pole switch to a split-wired duplex conve- nience outlet Problem 19–2 Draw a typical small bathroom layout with a tub, water closet, one sink vanity, one wall-mounted light over the sink with a single-pole switch at the door, a GFCI duplex convenience outlet next to the sink, a ceiling-mounted light-fan-heat unit with a timed switch at the door, and a proper vent note for the fan. Problem 19–3 Draw a typical kitchen layout with a double light above the sink, dishwasher, range with oven below and proper vent note, refrigerator, centered ceiling-recessed fluorescent lighting fixture, adequate GFCI duplex convenience outlets, and garbage disposal. 460 Architectural Drafting and Design Problem 19–4 Use the drawing of the house floor plan that you started in Chapter 18 and do one of the following as directed by your instructor: a. Continue by drawing the electrical plan on the same floor plan or plans that you completed in Chapter 18. Use the steps outlined in this chapter. b. Use the floor plan or plans that you created in Chapter 18 as the base drawing and create a separate electrical plan as outlined in the steps provided in this chapter. c. Prepare your CADD drawing using the appropriate electrical plan layers.