Catalog Number Notes Type FEATURES INTENDED USE — Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. CONSTRUCTION — White, compact, low-profile contemporary design with UVstabilized thermoplastic housing that is impact and scratch-resistant. Two 5.4W wedge-base krypton lamps offer 32 percent more light output than standard incandescent lamps. Thermoplastic Emergency Light ELM Patent-pending reflector/refractor design significantly improves photometrics. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Universal J-box mounting pattern. Lead-Calcium Battery Low-profile, integrated test switch/pilot light. Tool-less access for maintenance. Easily visible bright red status indicator. Flexible conduit entry provision on top of the unit. Ceiling mount standard. U.S. Patent No. D483,511 BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W to 18W (CSA) rated capacity. Automatic 48-hour recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection. Galvanized battery retaining clip. ELECTRONICS — Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal. LISTING — UL Listed. NOM Certified. ELM and ELM DL meet UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. ELM CSR meets UL 1310 and UL73. WARRANTY — Three-year total customer satisfaction warranty. For details, see the Product Selection Guide. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELM ELM Family ELM Options CSR DL Eight-foot cordset (120V) Damp location listed (10o - 40oC)1 Accessories Order as separate items. NOTES: 1 Not available with CSR option. Emergency ELA VS Thermoplastic vandal shield ELA WGST Wireguard Sheet #: ELM QMUE - 100 ELM Quantum® Thermoplastic Emergency Light SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are inches (millimeters). Shipping weight: 3.0 lbs. (1.4 kgs.) Type Volts 120 AC Input Amps Watts .11 1.2 Output Volts ELM 6 277 .12 Watts Output 1/2hr. 1hr. 1-1/2hrs. 2hrs. * * 12 11.5" (292.1) 9 5" (127) 1.5 * Half hour and one hour run time not applicable for U.S. product. BATTERY Sealed Lead-Calcium Voltage 6 Shelf life1 6 mos. 3.75" (95.25) Expected life1 Maintenance 5-8 yrs. none3 Optimum temperature2 Mounting Plate 60-90°F (16-32°C) 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 30 to 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. 1.91" (48.51) 2.5" (63.5) 5" 3.91" (127) (99.31) 5.63" (143) 3.75" (95.25) 11.5" (292.1) LAMP PHOTOMETRICS FIXTURE PERFORMANCE Consult factory for photometric information. Consult factory for fixture performance information. KEY FEATURES OPTION Unit snaps to mounting plate — no additional mechanical fasteners needed. ELM CSR option with eight-foot cordset. Lithonia Lighting Sheet #: ELM ©1991 Acuity Brands Lighting, Inc., Rev. 6/25/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com EMERGENCY LIGHTING UNITS Contemporary Thermoplastic Emergency Lighting Units ® Quantum ELM/ELM2 Quick-Mount ® Intended Use Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. Features White, compact, low-profile contemporary design with high-impact thermoplastic housing that is impact-resistant, corrosion-proof and UVstable to resist discoloration from artificial light sources or sunlight. Maintenance-free lead-calcium battery. ELM ELM2 to the path of egress. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Unique track-and-swivel design permits full range of lamp head adjustment (ELM2). Universal J-box mounting pattern. Tool-less access for maintenance. Flexible conduit entry provision on top of the unit. Quick-Mount® snap-together construction permits installation in three easy steps in less than three minutes. Vandal-resistant ELA VS polycarbonate shield available. Two 5.4W wedge-based krypton lamps offer 32 percent more light output than standard incandescent lamps. Wall or ceiling mounted. Patented MR24, multi-faceted reflector (ELM2) significantly improves photometric performance; 60 to 100 percent more light delivered UL Listed (standard). CSA Certified or NOM Certified (see Options). Listings Example: ELM2 SD Ordering Information Options Family ELM 6V,12W ELM2 6V,12W Accessories (Order separately) ELA VS Polycarbonate vandal shield ELA WGST Wireguard SD B DL CSR CSA NOM Type See page11 for details about LightQuick XD. Description ELM ELM2 SD1,2 B1,2,3 DL1,3 CSR1,4 CSA5 NOM1,2 ■ ELM LITHONIA EMERGENCY ELM2 438 Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (millimeters) unless otherwise noted. ELM ELM2 Width: 11-1/2(292) Width: 12-1/2(317) Depth: 3-3/4 (95.25) Depth: 3-3/4 (95.25) Height: 5(127) Height: 5(127) Weight: 3.0 lbs. (1.4 kgs.) Weight: 4.0 lbs. (1.8 kgs.) Type ELM2 11-3/4(298) 2-3/8 (60) 5(127) 3.0 lbs. (1.4 kgs.) ELM2 CSA Width: Depth: Height: Weight: ■ ■ ■ ■ ■ ■ ■ Lamp Number K0606 5.4 MR24 K0606 5.4 Volts 120 277 120 277 AC Input Amps .11 .12 .11 .12 Electrical Application Data Output Watts Volts 1-1/2 hrs 1.2 6 12 1.5 1.2 6 12 1.5 ELM/ELM2 Quick-Mount® Installation: 16-1/4(412) 4(102) 5 -1/8 (130) 4.0 lbs. (1.8 kgs.) Watt/ Lamp ■ Option available (blank) Option not available ELM ELM CSA Width: Depth: Height: Weight: Express delivery products. Self-diagnostics1,2 Black housing1,2,3 Damp location1,3 8-foot cordset attached (120V ELM only)1,4 CSA Certified5 NOM Certified1,2 1) Feed leads through mounting plate and make connections to AC power supply. 2) Align mounting plate on J-box and secure with screws. 3) Connect battery and snap housing onto mounting plate. www.lithonia.com,keyword: ELM Output Watts 2 hrs 3 hrs 4 hrs — — — — — — NOTES: 1 Not available with CSA option. 2 Available on ELM2 only. 3 Black ELM2 not available with damp location option. 4 Available on ELM only. 5 See CSA diagram for special housing dimensions. For additional lamp heads, remote fixtures, options and accessories, see pages 449-451. For application guidelines and fixture performance data, see pages 455 and 458. PSG9